PROGRESS IN DESIGN OF THE INSTRUMENTATION AND CONTROL OF THE TOKAMAK COOLING WATER SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, Kofi; DeVan, Bill; Ashburn, David
This paper discusses progress in the design of the control, interlock and safety systems of the Tokamak Cooling Water System (TCWS) for the ITER fusion reactor. The TCWS instrumentation and control (I&C) is one of approximately 200 separate plant I&C systems (e.g., vacuum system I&C, magnets system I&C) that interface to a common central I&C system through standardized networks. Several aspects of the I&C are similar to the I&C of fission-based power plants. However, some of the unique features of the ITER fusion reactor and the TCWS (e.g., high quasi-static magnetic field, need for baking and drying as well asmore » cooling operations), also demand some unique safety and qualification considerations. The paper compares the design strategy/guidelines of the TCWS I&C and the I&C of conventional nuclear power plants. Issues such as safety classifications, independence between control and safety systems, sensor sharing, redundancy, voting schemes, and qualification methodologies are discussed. It is concluded that independence and separation requirements are similar in both designs. However, the voting schemes for safety systems in nuclear power plants typically use 2oo4 (i.e., 4 divisions of safety I&C, any 2 of which is sufficient to trigger a safety action), while 2oo3 voting logic - within each of 2 independent trains - is used in the TCWS I&C. It is also noted that 2oo3 voting is also acceptable in nuclear power plants if adequate risk assessment and reliability is demonstrated. Finally, while qualification requirements provide similar guidance [e.g., both IEC 60780 (invoked in ITER-space), and IEEE 323 (invoked in fission power plant space) provide similar guidance], an important qualification consideration is the susceptibility of I&C to the magnetic fields of ITER. Also, the radiation environments are different. In the case of magnetic fields the paper discusses some options that are being considered.« less
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
40 CFR 51.119 - Intermittent control systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., 1970, and was operated as specified by the operating system of the ICS before December 31, 1970. (3... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Intermittent control systems. 51.119... Intermittent control systems. (a) The use of an intermittent control system (ICS) may be taken into account in...
Chen, Qian; Abercrombie, Robert K; Sheldon, Frederick T.
2015-09-23
Industrial Control Systems (ICS) are commonly used in industries such as oil and natural gas, transportation, electric, water and wastewater, chemical, pharmaceutical, pulp and paper, food and beverage, as well as discrete manufacturing (e.g., automotive, aerospace, and durable goods.) SCADA systems are generally used to control dispersed assets using centralized data acquisition and supervisory control.Originally, ICS implementations were susceptible primarily to local threats because most of their components were located in physically secure areas (i.e., ICS components were not connected to IT networks or systems). The trend toward integrating ICS systems with IT networks (e.g., efficiency and the Internet ofmore » Things) provides significantly less isolation for ICS from the outside world thus creating greater risk due to external threats. Albeit, the availability of ICS/SCADA systems is critical to assuring safety, security and profitability. Such systems form the backbone of our national cyber-physical infrastructure.Herein, we extend the concept of mean failure cost (MFC) to address quantifying availability to harmonize well with ICS security risk assessment. This new measure is based on the classic formulation of Availability combined with Mean Failure Cost (MFC). Finally, the metric offers a computational basis to estimate the availability of a system in terms of the loss that each stakeholder stands to sustain as a result of security violations or breakdowns (e.g., deliberate malicious failures).« less
Migration of Older to New Digital Control Systems in Nuclear Power Plant Main Control Rooms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, Casey Robert; Joe, Jeffrey Clark
The United States (U.S.) Department of Energy (DOE) Office of Nuclear Energy (NE) has the primary mission to advance nuclear power by resolving socio-technical issues through research and development (R&D). One DOE-NE activity supporting this mission is the Light Water Reactor Sustainability (LWRS) program. LWRS has the overall objective to sustain the operation of existing commercial nuclear power plants (NPPs) through conducting R&D across multiple “pathways,” or R&D focus areas. The Advanced Instrumentation, Information, and Control (II&C) Systems Technologies pathway conducts targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systemsmore » in operating U.S. NPPs. This work involves (1) ensuring that legacy analog II&C systems are not life-limiting issues for the LWR fleet, and (2) implementing digital II&C technology in a manner that enables broad innovation and business improvement in the NPP operating model. Under the LWRS Advanced II&C pathway, Human Factors experts at Idaho National Laboratory (INL) have been conducting R&D in support of NPP main control room (MCR) modernization activities. Work in prior years has focused on migrating analog I&C systems to new digital I&C systems (). In fiscal year 2016 (FY16), one new focus area for this research is migrating older digital I&C systems to new and advanced digital I&C systems. This report summarizes a plan for conducting a digital-to-digital migration of a legacy digital I&C system to a new digital I&C system in support of control room modernization activities.« less
Roos, Leslie E.; Knight, Erik L.; Beauchamp, Kathryn G.; Berkman, Elliot T.; Faraday, Kelsie; Hyslop, Katie; Fisher, Philip A.
2017-01-01
Identifying environmental influences on inhibitory control (IC) may help promote positive behavioral and social adjustment. Although chronic stress is known to predict lower IC, the immediate effects of acute stress are unknown. The parasympathetic nervous system (PNS) may be a mechanism of the stress-IC link, given its psychophysiological regulatory role and connections to prefrontal brain regions critical to IC. We used a focused assessment of IC (the stop-signal task) to test whether an acute social stressor (the Trier Social Stress Test) affected participants’ pre- to post-IC performance (n = 58), compared to a control manipulation (n = 31). High frequency heart-rate variability was used as an index of PNS activity in response to the manipulation. Results indicated that stress impaired IC performance, blocking the practice effects observed in control participants. We also investigated the associations between PNS activity and IC; higher resting PNS activity predicted better pre-manipulation IC, and greater PNS stressor reactivity protected against the negative effects of stress on IC. Together, these results are the first to document the immediate effects of acute stress on IC and a phenotypic marker (PNS reactivity to stressors) of susceptibility to stress-induced IC impairment. This study suggests a new way to identify situations in which individuals are likely to exhibit IC vulnerability and related consequences such as impulsivity and risk taking behavior. Targeting PNS regulation may represent a novel target for IC-focused interventions. PMID:28268165
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, R.; Melin, A.; Burress, T.
The objective of this project is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant (NPP) components and systems. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration platform. I&C is intimately part of the basic millisecond-by-millisecond functioning of the system; treating I&C as an integral part of the system design is innovative and will allow significant improvement in capabilities and performance. As systems become more complex and greater performance is required, traditional I&C design techniques become inadequate andmore » more advanced I&C needs to be applied. New I&C techniques enable optimal and reliable performance and tolerance of noise and uncertainties in the system rather than merely monitoring quasistable performance. Traditionally, I&C has been incorporated in NPP components after the design is nearly complete; adequate performance was obtained through over-design. By incorporating I&C at the beginning of the design phase, the control system can provide superior performance and reliability and enable designs that are otherwise impossible. This report describes the progress and status of the project and provides a conceptual design overview for the platform to demonstrate the performance and reliability improvements enabled by advanced embedded I&C.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... Subcommittee On Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation and Control (DI&C) Systems... the area of Digital Instrumentation and Control (DI&C) Probabilistic Risk Assessment (PRA). Topics... software reliability methods (QSRMs), NUREG/CR--6997, ``Modeling a Digital Feedwater Control System Using...
International Space Agency CIO Forum Industrial Control System (ICS) and Cyber
NASA Technical Reports Server (NTRS)
Powell, Robert
2017-01-01
This briefing covers Industrial Control System (ICS) best practices for enhancing cyber protection. The briefing provides a very high-level overview of best practices currently being pursued by NASA as well as by other US government agencies such as NIST and DHS ICS-CERT. All information presented in this slide deck is publicly available and no sensitive information is provided in these slides. These slides will be used to generate discussion around best practices within the international community in the area of ICS cyber protections.
Detecting Cyber Attacks On Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Rrushi, Julian; Campbell, Roy
This paper proposes an unconventional anomaly detection approach that provides digital instrumentation and control (I&C) systems in a nuclear power plant (NPP) with the capability to probabilistically discern between legitimate protocol frames and attack frames. The stochastic activity network (SAN) formalism is used to model the fusion of protocol activity in each digital I&C system and the operation of physical components of an NPP. SAN models are employed to analyze links between protocol frames as streams of bytes, their semantics in terms of NPP operations, control data as stored in the memory of I&C systems, the operations of I&C systems on NPP components, and NPP processes. Reward rates and impulse rewards are defined in the SAN models based on the activity-marking reward structure to estimate NPP operation profiles. These profiles are then used to probabilistically estimate the legitimacy of the semantics and payloads of protocol frames received by I&C systems.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... NUCLEAR REGULATORY COMMISSION Advisory Committee on Reactor Safeguards (ACRS); Meeting of the ACRS Subcommittee on Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation and Controls (I&C) Systems...: Wednesday, September 8, 2010--8:30 a.m. until 12 p.m. The Subcommittee will review Digital I&C Interim Staff...
Simultaneous control of multiple instruments at the Advanced Technology Solar Telescope
NASA Astrophysics Data System (ADS)
Johansson, Erik M.; Goodrich, Bret
2012-09-01
The Advanced Technology Solar Telescope (ATST) is a 4-meter solar observatory under construction at Haleakala, Hawaii. The simultaneous use of multiple instruments is one of the unique capabilities that makes the ATST a premier ground based solar observatory. Control of the instrument suite is accomplished by the Instrument Control System (ICS), a layer of software between the Observatory Control System (OCS) and the instruments. The ICS presents a single narrow interface to the OCS and provides a standard interface for the instruments to be controlled. It is built upon the ATST Common Services Framework (CSF), an infrastructure for the implementation of a distributed control system. The ICS responds to OCS commands and events, coordinating and distributing them to the various instruments while monitoring their progress and reporting the status back to the OCS. The ICS requires no specific knowledge about the instruments. All information about the instruments used in an experiment is passed by the OCS to the ICS, which extracts and forwards the parameters to the appropriate instrument controllers. The instruments participating in an experiment define the active instrument set. A subset of those instruments must complete their observing activities in order for the experiment to be considered complete and are referred to as the must-complete instrument set. In addition, instruments may participate in eavesdrop mode, outside of the control of the ICS. All instrument controllers use the same standard narrow interface, which allows new instruments to be added without having to modify the interface or any existing instrument controllers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Hara, J.M.; W. Gunther, G. Martinez-Guridi
New and advanced reactors will use integrated digital instrumentation and control (I&C) systems to support operators in their monitoring and control functions. Even though digital systems are typically highly reliable, their potential for degradation or failure could significantly affect operator performance and, consequently, impact plant safety. The U.S. Nuclear Regulatory Commission (NRC) supported this research project to investigate the effects of degraded I&C systems on human performance and plant operations. The objective was to develop human factors engineering (HFE) review guidance addressing the detection and management of degraded digital I&C conditions by plant operators. We reviewed pertinent standards and guidelines,more » empirical studies, and plant operating experience. In addition, we conducted an evaluation of the potential effects of selected failure modes of the digital feedwater system on human-system interfaces (HSIs) and operator performance. The results indicated that I&C degradations are prevalent in plants employing digital systems and the overall effects on plant behavior can be significant, such as causing a reactor trip or causing equipment to operate unexpectedly. I&C degradations can impact the HSIs used by operators to monitor and control the plant. For example, sensor degradations can make displays difficult to interpret and can sometimes mislead operators by making it appear that a process disturbance has occurred. We used the information obtained as the technical basis upon which to develop HFE review guidance. The guidance addresses the treatment of degraded I&C conditions as part of the design process and the HSI features and functions that support operators to monitor I&C performance and manage I&C degradations when they occur. In addition, we identified topics for future research.« less
2016-08-10
enable JCS managers to detect advanced cyber attacks, mitigate the effects of those attacks, and recover their networks following an attack. It also... managers of ICS networks to Detect, Mitigate, and Recover from nation-state-level cyber attacks (strategic, deliberate, well-trained, and funded...Successful Detection of cyber anomalies is best achieved when IT and ICS managers remain in close coordination. The Integrity Checks Table
Pasma, Jantsje H.; Assländer, Lorenz; van Kordelaar, Joost; de Kam, Digna; Mergner, Thomas; Schouten, Alfred C.
2018-01-01
The Independent Channel (IC) model is a commonly used linear balance control model in the frequency domain to analyze human balance control using system identification and parameter estimation. The IC model is a rudimentary and noise-free description of balance behavior in the frequency domain, where a stable model representation is not guaranteed. In this study, we conducted firstly time-domain simulations with added noise, and secondly robot experiments by implementing the IC model in a real-world robot (PostuRob II) to test the validity and stability of the model in the time domain and for real world situations. Balance behavior of seven healthy participants was measured during upright stance by applying pseudorandom continuous support surface rotations. System identification and parameter estimation were used to describe the balance behavior with the IC model in the frequency domain. The IC model with the estimated parameters from human experiments was implemented in Simulink for computer simulations including noise in the time domain and robot experiments using the humanoid robot PostuRob II. Again, system identification and parameter estimation were used to describe the simulated balance behavior. Time series, Frequency Response Functions, and estimated parameters from human experiments, computer simulations, and robot experiments were compared with each other. The computer simulations showed similar balance behavior and estimated control parameters compared to the human experiments, in the time and frequency domain. Also, the IC model was able to control the humanoid robot by keeping it upright, but showed small differences compared to the human experiments in the time and frequency domain, especially at high frequencies. We conclude that the IC model, a descriptive model in the frequency domain, can imitate human balance behavior also in the time domain, both in computer simulations with added noise and real world situations with a humanoid robot. This provides further evidence that the IC model is a valid description of human balance control. PMID:29615886
Pasma, Jantsje H; Assländer, Lorenz; van Kordelaar, Joost; de Kam, Digna; Mergner, Thomas; Schouten, Alfred C
2018-01-01
The Independent Channel (IC) model is a commonly used linear balance control model in the frequency domain to analyze human balance control using system identification and parameter estimation. The IC model is a rudimentary and noise-free description of balance behavior in the frequency domain, where a stable model representation is not guaranteed. In this study, we conducted firstly time-domain simulations with added noise, and secondly robot experiments by implementing the IC model in a real-world robot (PostuRob II) to test the validity and stability of the model in the time domain and for real world situations. Balance behavior of seven healthy participants was measured during upright stance by applying pseudorandom continuous support surface rotations. System identification and parameter estimation were used to describe the balance behavior with the IC model in the frequency domain. The IC model with the estimated parameters from human experiments was implemented in Simulink for computer simulations including noise in the time domain and robot experiments using the humanoid robot PostuRob II. Again, system identification and parameter estimation were used to describe the simulated balance behavior. Time series, Frequency Response Functions, and estimated parameters from human experiments, computer simulations, and robot experiments were compared with each other. The computer simulations showed similar balance behavior and estimated control parameters compared to the human experiments, in the time and frequency domain. Also, the IC model was able to control the humanoid robot by keeping it upright, but showed small differences compared to the human experiments in the time and frequency domain, especially at high frequencies. We conclude that the IC model, a descriptive model in the frequency domain, can imitate human balance behavior also in the time domain, both in computer simulations with added noise and real world situations with a humanoid robot. This provides further evidence that the IC model is a valid description of human balance control.
Protecting ICS Systems Within the Energy Sector from Cyber Attacks
NASA Astrophysics Data System (ADS)
Barnes, Shaquille
Advance persistent threat (APT) groups are continuing to attack the energy sector through cyberspace, which poses a risk to our society, national security, and economy. Industrial control systems (ICSs) are not designed to handle cyber-attacks, which is why asset owners need to implement the correct proactive and reactive measures to mitigate the risk to their ICS environments. The Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) responded to 290 incidents for fiscal year 2016, where 59 of those incidents came from the Energy Sector. APT groups know how vulnerable energy sector ICS systems are and the destruction they can cause when they go offline such as loss of production, loss of life, and economic impact. Defending against APT groups requires more than just passive controls such as firewalls and antivirus solutions. Asset owners should implement a combination of best practices and active defense in their environment to defend against APT groups. Cyber-attacks against critical infrastructure will become more complex and harder to detect and respond to with traditional security controls. The purpose of this paper was to provide asset owners with the correct security controls and methodologies to help defend against APT groups.
Fakih, Mohamad G; Skierczynski, Boguslow; Bufalino, Angelo; Groves, Clariecia; Roberts, Phillip; Heavens, Michelle; Hendrich, Ann; Haydar, Ziad
2016-12-01
The standardized infection ratio (SIR) evaluates individual publicly reported health care-associated infections, but it may not assess overall performance. We piloted an infection composite score (ICS) in 82 hospitals of a single health system. The ICS is a combined score for central line-associated bloodstream infections, catheter-associated urinary tract infections, colon and abdominal hysterectomy surgical site infections, and hospital-onset methicillin-resistant Staphylococcus aureus bacteremia and Clostridium difficile infections. Individual facility ICSs were calculated by normalizing each of the 6 SIR events to the system SIR for baseline and performance periods (ICS ib and ICS ip , respectively). A hospital ICS ib reflected its baseline performance compared with system baseline, whereas a ICS ip provided information of its outcome changes compared with system baseline. Both the ICS ib (baseline 2013) and ICS ip (performance 2014) were calculated for 63 hospitals (reporting at least 4 of the 6 event types). The ICS ip improved in 36 of 63 (57.1%) hospitals in 2014 when compared with the ICS ib in 2013. The ICS ib 2013 median was 0.96 (range, 0.13-2.94) versus the 2014 ICS ip median of 0.92 (range, 0-6.55). Variation was more evident in hospitals with ≤100 beds. The system performance score (ICS sp ) in 2014 was 0.95, a 5% improvement compared with 2013. The proposed ICS may help large health systems and state hospital associations better evaluate key infectious outcomes, comparing them with historic and concurrent performance of peers. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
ICS logging solution for network-based attacks using Gumistix technology
NASA Astrophysics Data System (ADS)
Otis, Jeremy R.; Berman, Dustin; Butts, Jonathan; Lopez, Juan
2013-05-01
Industrial Control Systems (ICS) monitor and control operations associated with the national critical infrastructure (e.g., electric power grid, oil and gas pipelines and water treatment facilities). These systems rely on technologies and architectures that were designed for system reliability and availability. Security associated with ICS was never an inherent concern, primarily due to the protections afforded by network isolation. However, a trend in ICS operations is to migrate to commercial networks via TCP/IP in order to leverage commodity benefits and cost savings. As a result, system vulnerabilities are now exposed to the online community. Indeed, recent research has demonstrated that many exposed ICS devices are being discovered using readily available applications (e.g., ShodanHQ search engine and Google-esque queries). Due to the lack of security and logging capabilities for ICS, most knowledge about attacks are derived from real world incidents after an attack has already been carried out and the damage has been done. This research provides a method for introducing sensors into the ICS environment that collect information about network-based attacks. The sensors are developed using an inexpensive Gumstix platform that can be deployed and incorporated with production systems. Data obtained from the sensors provide insight into attack tactics (e.g., port scans, Nessus scans, Metasploit modules, and zero-day exploits) and characteristics (e.g., attack origin, frequency, and level of persistence). Findings enable security professionals to draw an accurate, real-time awareness of the threats against ICS devices and help shift the security posture from reactionary to preventative.
DOT National Transportation Integrated Search
2013-07-29
The John A. Volpe National Transportation Systems Center was asked by the Office of Security of the Maritime Administration to examine the issue of industrial control systems (ICS) security in the Maritime Transportation System (MTS), and to develop ...
A Survey of Security Tools for the Industrial Control System Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurd, Carl M.; McCarty, Michael V.
This report details the results of a survey conducted by Idaho National Laboratory (INL) to identify existing tools which could be used to prevent, detect, mitigate, or investigate a cyber-attack in an industrial control system (ICS) environment. This report compiles a list of potentially applicable tools and shows the coverage of the tools in an ICS architecture.
NASA Astrophysics Data System (ADS)
Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei
2018-01-01
High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (Hc2) and critical temperature (Tc). The critical current (Ic) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new Ic measurement system that can carry out accurate Ic measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The Ic measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa2Cu3O7-x(YBCO) tapes Ic determination with different temperatures and magnetic fields.
Embedded I&C for Extreme Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, Roger A.
2016-04-01
This project uses embedded instrumentation and control (I&C) technologies to demonstrate potential performance gains of nuclear power plant components in extreme environments. Extreme environments include high temperature, radiation, high pressure, high vibration, and high EMI conditions. For extreme environments, performance gains arise from moment-to-moment sensing of local variables and immediate application of local feedback control. Planning for embedding I&C during early system design phases contrasts with the traditional, serial design approach that incorporates minimal I&C after mechanical and electrical design is complete. The demonstration application involves the development and control of a novel, proof-of-concept motor/pump design. The motor and pumpmore » combination operate within the fluid environment, eliminating the need for rotating seals. Actively controlled magnetic bearings also replace failure-prone mechanical contact bearings that typically suspend rotating components. Such as design has the potential to significantly enhance the reliability and life of the pumping system and would not be possible without embedded I&C.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to testmore » the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Self-Adaptive System based on Field Programmable Gate Array for Extreme Temperature Electronics
NASA Technical Reports Server (NTRS)
Keymeulen, Didier; Zebulum, Ricardo; Rajeshuni, Ramesham; Stoica, Adrian; Katkoori, Srinivas; Graves, Sharon; Novak, Frank; Antill, Charles
2006-01-01
In this work, we report the implementation of a self-adaptive system using a field programmable gate array (FPGA) and data converters. The self-adaptive system can autonomously recover the lost functionality of a reconfigurable analog array (RAA) integrated circuit (IC) [3]. Both the RAA IC and the self-adaptive system are operating in extreme temperatures (from 120 C down to -180 C). The RAA IC consists of reconfigurable analog blocks interconnected by several switches and programmable by bias voltages. It implements filters/amplifiers with bandwidth up to 20 MHz. The self-adaptive system controls the RAA IC and is realized on Commercial-Off-The-Shelf (COTS) parts. It implements a basic compensation algorithm that corrects a RAA IC in less than a few milliseconds. Experimental results for the cold temperature environment (down to -180 C) demonstrate the feasibility of this approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rades, Dirk, E-mail: Rades.Dirk@gmx.net; Dziggel, Liesa; Haatanen, Tiina
2011-07-15
Purpose: To create and validate scoring systems for intracerebral control (IC) and overall survival (OS) of patients irradiated for brain metastases. Methods and Materials: In this study, 1,797 patients were randomly assigned to the test (n = 1,198) or the validation group (n = 599). Two scoring systems were developed, one for IC and another for OS. The scores included prognostic factors found significant on multivariate analyses. Age, performance status, extracerebral metastases, interval tumor diagnosis to RT, and number of brain metastases were associated with OS. Tumor type, performance status, interval, and number of brain metastases were associated with IC.more » The score for each factor was determined by dividing the 6-month IC or OS rate (given in percent) by 10. The total score represented the sum of the scores for each factor. The score groups of the test group were compared with the corresponding score groups of the validation group. Results: In the test group, 6-month IC rates were 17% for 14-18 points, 49% for 19-23 points, and 77% for 24-27 points (p < 0.0001). IC rates in the validation group were 19%, 52%, and 77%, respectively (p < 0.0001). In the test group, 6-month OS rates were 9% for 15-19 points, 41% for 20-25 points, and 78% for 26-30 points (p < 0.0001). OS rates in the validation group were 7%, 39%, and 79%, respectively (p < 0.0001). Conclusions: Patients irradiated for brain metastases can be given scores to estimate OS and IC. IC and OS rates of the validation group were similar to the test group demonstrating the validity and reproducibility of both scores.« less
Fog-computing concept usage as means to enhance information and control system reliability
NASA Astrophysics Data System (ADS)
Melnik, E. V.; Klimenko, A. B.; Ivanov, D. Ya
2018-05-01
This paper focuses on the reliability issue of information and control systems (ICS). The authors propose using the elements of the fog-computing concept to enhance the reliability function. The key idea of fog-computing is to shift computations to the fog-layer of the network, and thus to decrease the workload of the communication environment and data processing components. As for ICS, workload also can be distributed among sensors, actuators and network infrastructure facilities near the sources of data. The authors simulated typical workload distribution situations for the “traditional” ICS architecture and for the one with fogcomputing concept elements usage. The paper contains some models, selected simulation results and conclusion about the prospects of the fog-computing as a means to enhance ICS reliability.
Butt, Taimur S; Koutlakis-Barron, Irene; AlJumaah, Suliman; AlThawadi, Sahar; AlMofada, Saleh
2016-05-01
Transmission of Middle East respiratory syndrome-coronavirus (MERS-CoV) among health care workers (HCWs) and patients has been documented with mortality rate approximating 36%. We propose advanced infection control measures (A-IC) used in conjunction with basic infection control measures (B-IC) help reduce pathogen transmission. B-IC include standard and transmission-based precautions. A-IC are initiatives implemented within our center to enhance effectiveness of B-IC. Study effectiveness of combining B-IC and A-IC to prevent transmission of MERS-CoV to HCWs. A retrospective observational study was undertaken. A-IC measures include administrative support with daily rounds; infection control risk assessment; timely screening, isolation, and specimen analysis; collaboration; epidemic planning; stockpiling; implementation of contingency plans; full personal protective equipment use for advanced airway management; use of a real-time electronic isolation flagging system; infection prevention and control team on-call protocols; pretransfer MERS-CoV testing; and education. A total of 874 real-time polymerase chain reaction MERS-CoV tests were performed during the period beginning July 1, 2013, and ending January 31, 2015. Six hundred ninety-four non-HCWs were tested, of these 16 tested positive for MERS-CoV and their infection was community acquired. Sixty-nine percent of the confirmed MERS-CoV-positive cases were men, with an average age of 56 years (range, 19-84 years). Of the total tested for MERS-CoV, 180 individuals were HCWs with zero positivity. Adhering to a combination of B-IC and A-IC reduces the risk of MERS-CoV transmission to HCWs. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Chung, Shiu-Dong; Liu, Shih-Ping; Li, Hsien-Chang; Lin, Herng-Ching
2014-01-01
This study aims to investigate the differences in the utilization of healthcare services between patients with bladder pain syndrome/interstitial cystitis (BPS/IC) and patients without using a population-based database in Taiwan. This study comprised of 350 patients with BPS/IC and 1,750 age-matched controls. Healthcare resource utilization was evaluated in the one-year follow-up period as follows: number of outpatient visits and inpatient days, and the mean costs of outpatient and inpatient treatment. A multivariate regression analysis was used to evaluate the relationship between BPS/IC and total costs of health care services. For urological services, patients with BPS/IC had a significantly higher number of outpatient visits (2.5 vs. 0.2, p<0.001) as well as significantly higher outpatient costs ($US166 vs. $US6.8, p<0.001) than the controls. For non-urologic services, patients with BPS/IC had a significantly high number of outpatient visits (35.0 vs. 21.3, p<0.001) as well as significantly higher outpatient cots ($US912 vs. $US675, p<0.001) as compared to the controls. Overall, patients with BPS/IC had 174% more outpatient visits and 150% higher total costs than the controls. Multiple-regression-analyses also showed that the patients with BPS/IC had significantly higher total costs for all healthcare services than the controls. This study found that patients with BPS/IC have a significantly higher number of healthcare related visits, and have significantly higher healthcare related costs than age-matched controls. The high level of healthcare services utilization accrued with BPS/IC was not necessarily exclusive for BPS/IC, but may have also been associated with medical co-morbidities.
Giuliano, Ryan J; Roos, Leslie E; Farrar, Jessica D; Skowron, Elizabeth A
2018-04-01
A child's cumulative risk for early exposure to stress has been linked to alterations of self-regulation outcomes, including neurobiological correlates of inhibitory control (IC). We examined whether children's ability to engage the parasympathetic nervous system impacts how risk affects IC. Children ages 3-5 years completed two laboratory measures of IC while respiratory sinus arrhythmia (RSA) was measured, indexing parasympathetic activity. Children with greater risk demonstrated lower IC; risk also moderated associations between RSA reactivity and IC. For children with less risk, greater RSA withdrawal during IC tasks was associated with better IC. In contrast, greater risk was associated with poor IC, regardless of RSA withdrawal. Effects of risk were more pronounced for cumulative than individual measures. Results suggest that cumulative risk exposure disrupts connectivity between physiological and behavioral components of self-regulation in early childhood. Parasympathetic withdrawal to cognitive tasks may be less relevant for performance in developmental samples experiencing greater life stress. © 2018 Wiley Periodicals, Inc.
Finite-dimensional modeling of network-induced delays for real-time control systems
NASA Technical Reports Server (NTRS)
Ray, Asok; Halevi, Yoram
1988-01-01
In integrated control systems (ICS), a feedback loop is closed by the common communication channel, which multiplexes digital data from the sensor to the controller and from the controller to the actuator along with the data traffic from other control loops and management functions. Due to asynchronous time-division multiplexing in the network access protocols, time-varying delays are introduced in the control loop, which degrade the system dynamic performance and are a potential source of instability. The delayed control system is represented by a finite-dimensional, time-varying, discrete-time model which is less complex than the existing continuous-time models for time-varying delays; this approach allows for simpler schemes for analysis and simulation of the ICS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-02-01
This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
System and method for interfacing large-area electronics with integrated circuit devices
Verma, Naveen; Glisic, Branko; Sturm, James; Wagner, Sigurd
2016-07-12
A system and method for interfacing large-area electronics with integrated circuit devices is provided. The system may be implemented in an electronic device including a large area electronic (LAE) device disposed on a substrate. An integrated circuit IC is disposed on the substrate. A non-contact interface is disposed on the substrate and coupled between the LAE device and the IC. The non-contact interface is configured to provide at least one of a data acquisition path or control path between the LAE device and the IC.
Analog Techniques in CEBAF's RF Control System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hovater, J.; Fugitt, Jock
1988-01-01
Recent developments in high-speed analog technology have progressed into the areas of traditional RF technology.Diode-related devices are being replaced by analog IC's in the CEBAF RF control system.Complex phase modulators and attenuators have been successfully tested at 70 MHz.They have three advantages over existing technology: lower cost, less temperature sensitivity, and more linearity.RF signal conditioning components and how to implement the new analog IC's will be covered in this paper.
Bladder Pain Syndrome/Interstitial Cystitis Is Associated with Hyperthyroidism
Liu, Shih-Ping; Lin, Ching-Chun; Lin, Herng-Ching
2013-01-01
Background Although the etiology of bladder pain syndrome/interstitial cystitis (BPS/IC) is still unclear, a common theme with BPS/IC patients is comorbid disorders which are related to the autonomic nervous system that connects the nervous system to end-organs. Nevertheless, no study to date has reported the association between hyperthyroidism and BPS/IC. In this study, we examined the association of IC/BPS with having previously been diagnosed with hyperthyroidism in Taiwan. Design Data in this study were retrieved from the Longitudinal Health Insurance Database. Our study consisted of 736 female cases with BPS/IC and 2208 randomly selected female controls. We performed a conditional logistic regression to calculate the odds ratio (OR) for having previously been diagnosed with hyperthyroidism between cases and controls. Results Of the 2944 sampled subjects, there was a significant difference in the prevalence of prior hyperthyroidism between cases and controls (3.3% vs. 1.5%, p<0.001). The conditional logistic regression analysis revealed that compared to controls, the OR for prior hyperthyroidism among cases was 2.16 (95% confidence interval (CI): 1.27∼3.66). Furthermore, the OR for prior hyperthyroidism among cases was 2.01 (95% CI: 1.15∼3.53) compared to controls after adjusting for diabetes, coronary heart disease, obesity, hyperlipidemia, chronic pelvic pain, irritable bowel syndrome, fibromyalgia, chronic fatigue syndrome, depression, panic disorder, migraines, sicca syndrome, allergies, endometriosis, and asthma. Conclusions Our study results indicated an association between hyperthyroidism and BPS/IC. We suggest that clinicians treating female subjects with hyperthyroidism be alert to urinary complaints in this population. PMID:23991081
Bladder pain syndrome/interstitial cystitis is associated with hyperthyroidism.
Chung, Shiu-Dong; Liu, Shih-Ping; Lin, Ching-Chun; Li, Hsien-Chang; Lin, Herng-Ching
2013-01-01
Although the etiology of bladder pain syndrome/interstitial cystitis (BPS/IC) is still unclear, a common theme with BPS/IC patients is comorbid disorders which are related to the autonomic nervous system that connects the nervous system to end-organs. Nevertheless, no study to date has reported the association between hyperthyroidism and BPS/IC. In this study, we examined the association of IC/BPS with having previously been diagnosed with hyperthyroidism in Taiwan. Data in this study were retrieved from the Longitudinal Health Insurance Database. Our study consisted of 736 female cases with BPS/IC and 2208 randomly selected female controls. We performed a conditional logistic regression to calculate the odds ratio (OR) for having previously been diagnosed with hyperthyroidism between cases and controls. Of the 2944 sampled subjects, there was a significant difference in the prevalence of prior hyperthyroidism between cases and controls (3.3% vs. 1.5%, p<0.001). The conditional logistic regression analysis revealed that compared to controls, the OR for prior hyperthyroidism among cases was 2.16 (95% confidence interval (CI): 1.27∼3.66). Furthermore, the OR for prior hyperthyroidism among cases was 2.01 (95% CI: 1.15∼3.53) compared to controls after adjusting for diabetes, coronary heart disease, obesity, hyperlipidemia, chronic pelvic pain, irritable bowel syndrome, fibromyalgia, chronic fatigue syndrome, depression, panic disorder, migraines, sicca syndrome, allergies, endometriosis, and asthma. Our study results indicated an association between hyperthyroidism and BPS/IC. We suggest that clinicians treating female subjects with hyperthyroidism be alert to urinary complaints in this population.
Cyber Security Testing and Training Programs for Industrial Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel Noyes
2012-03-01
Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall securitymore » posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.« less
Instrument control software development process for the multi-star AO system ARGOS
NASA Astrophysics Data System (ADS)
Kulas, M.; Barl, L.; Borelli, J. L.; Gässler, W.; Rabien, S.
2012-09-01
The ARGOS project (Advanced Rayleigh guided Ground layer adaptive Optics System) will upgrade the Large Binocular Telescope (LBT) with an AO System consisting of six Rayleigh laser guide stars. This adaptive optics system integrates several control loops and many different components like lasers, calibration swing arms and slope computers that are dispersed throughout the telescope. The purpose of the instrument control software (ICS) is running this AO system and providing convenient client interfaces to the instruments and the control loops. The challenges for the ARGOS ICS are the development of a distributed and safety-critical software system with no defects in a short time, the creation of huge and complex software programs with a maintainable code base, the delivery of software components with the desired functionality and the support of geographically distributed project partners. To tackle these difficult tasks, the ARGOS software engineers reuse existing software like the novel middleware from LINC-NIRVANA, an instrument for the LBT, provide many tests at different functional levels like unit tests and regression tests, agree about code and architecture style and deliver software incrementally while closely collaborating with the project partners. Many ARGOS ICS components are already successfully in use in the laboratories for testing ARGOS control loops.
Plasticity of serotonergic innervation of the inferior colliculus in mice following acoustic trauma
Papesh, Melissa A.; Hurley, Laura M.
2012-01-01
Acoustic trauma often results in permanent damage to the cochlea, triggering changes in processing within central auditory structures such as the inferior colliculus (IC). The serotonergic neuromodulatory system, present in the IC, is responsive to chronic changes in the activity of sensory systems. The current study investigated whether the density of serotonergic innervation in the IC is changed following acoustic trauma. The trauma stimulus consisted of an 8 kHz pure tone presented at a level of 113 dB SPL for six consecutive hours to anesthetized CBA/J mice. Following a minimum recovery period of three weeks, serotonergic fibers were visualized via histochemical techniques targeting the serotonin reuptake transporter (SERT) and quantified using stereologic probes. SERT-positive fiber densities were then compared between the traumatized and protected hemispheres of unilaterally traumatized subjects and those of controls. A significant effect of acoustic trauma was found between the hemispheres of unilaterally traumatized subjects such that the IC contralateral to the ear of exposure contained a lower density of SERT-positive fibers than the IC ipsilateral to acoustic trauma. No significant difference in density was found between the hemispheres of control subjects. Additional dimensions of variability in serotonergic fibers were seen among subdivisions of the IC and with age. The central IC had a slightly but significantly lowered density of serotonergic fibers than other subdivisions of the IC, and serotonergic fibers also declined with age. Overall, the results indicate that acoustic trauma is capable of producing modest but significant decreases in the density of serotonergic fibers innervating the IC. PMID:22101024
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-11
... NUCLEAR REGULATORY COMMISSION Advisory Committee on Reactor Safeguards (ACRS); Meeting of the ACRS Subcommittee on Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation & Control (DI&C) Systems will hold a meeting on February 23, 2011, Room T-2B3, 11545 Rockville Pike, Rockville, Maryland. The...
Turusbekova, N; Popa, C; Dragos, M; van der Werf, M J; Dinca, I
2016-02-01
In 2012, the tuberculosis (TB) notification rate among Romanian TB facility doctors and nurses was 7.2 times higher than in the general population. This indicates that transmission is ongoing inside TB facilities and that TB infection control measures are insufficient. To help prevent nosocomial TB transmission a project was implemented that aimed at providing nationwide tailor-made technical assistance in TB infection control (TB-IC) in TB treatment facilities, including the development of TB infection control plans. The objective of the present article is to describe the implementation of the project and to discuss successes and challenges. The project was an implementation study using two methods of evaluation: (1) a cross sectional questionnaire study; and (2) collection of information, during the training, on challenges related to infection control and to the project implementation. The project team developed a TB facility infection control (TB-IC) plan template, together with the Romanian experts. The template was discussed and agreed upon with the experts at a meeting and thereafter distributed by email to all TB facilities. Afterwards, a training of trainers (TOT) seminar was organized which included the provision of information about different training methods, as well as information about TB-IC. The TOT was followed by training for key TB-IC providers. Information about use of the TB-IC template was gathered through a self-administered questionnaire sent to all participants of the expert meeting and the training (42 people). Additionally, non-systematized discussions were held on broader challenges in TB-IC implementation during the training. Within the project 42 key TB-IC service providers were trained in TB-IC, including 9 who were trained at a TOT seminar. The trainees were specialists working at the national level, such as country TB coordinators, or at the TB facility level: TB doctors, epidemiologists, laboratory specialists and maintenance engineers. Out of 42 key TB-IC service providers who were trained, only eighteen responded to the questionnaire (no reminders were sent). Out of these, 14 had used the TB-IC plan template after the project team disseminated it to them by email. The remaining four TB-IC service providers indicated that they were planning to use the template to develop or update their facility TB-IC plans. Related to the use of TB-IC plan template, the following broader challenges in TB-IC were identified: a lack of authority of the individuals responsible for TB-IC to implement the TB-IC measures, lack of training among facility epidemiologists on TB, underdeveloped system for reporting TB in healthcare workers, difficulties with triage of the TB suspects, and poor facility infrastructure hampering implementation of TB-IC measures. Implementing TB-IC plans in Romanian health care facilities proved to be challenging, mainly due to the fact that the national infection control plan for TB was not yet adopted at the time of project implementation, and therefore there was neither a regulatory framework to support TB facility-IC planning nor any related budget allocations for the implementation of the facilities' TB-IC plans. Nonetheless, most respondents who answered the questionnaire (18 of 42 responded) indicated that they had started using the TB-IC plan template, which represents a full package of infection control measures that, when implemented effectively and in its entirety, may be expected to reduce nosocomial transmission. The study's limitations are: very low survey response rate, thus there is a likelihood of responder bias. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Reddel, Helen K; Beckert, Lutz; Moran, Angela; Ingham, Tristram; Ampon, Rosario D; Peters, Matthew J; Sawyer, Susan M
2017-11-01
New Zealand (NZ) and Australia (AU) have similarly high asthma prevalence; both have universal public health systems, but different criteria for subsidized medicines. We explored differences in asthma management and asthma-related outcomes between these countries. A web-based survey was administered in AU (2012) and NZ (2013) to individuals aged ≥16 years with current asthma, drawn randomly from web-based panels, stratified by national population proportions. Symptom control was assessed with the Asthma Control Test (ACT). Healthcare utilization was assessed from reported urgent doctor/hospital visits in the previous year. NZ (n = 537) and Australian (n = 2686) participants had similar age and gender distribution. More NZ than Australian participants used inhaled corticosteroid (ICS)-containing medication (68.8% vs 60.9%; P = 0.006) but ICS/long-acting β 2 -agonist (LABA) constituted 44.4% of NZ and 81.5% of Australian total ICS use (P < 0.0001). Adherence was higher with ICS/LABA than ICS-alone (P < 0.0001), and higher in NZ than in AU (P < 0.0001). ACT scores were similar (P = 0.41), with symptoms well controlled in 58.6% and 54.4% participants, respectively. More NZ participants reported non-urgent asthma reviews (56.6% vs 50.4%; P = 0.009). Similar proportions had urgent asthma visits (27.9% and 28.6%, respectively, P = 0.75). This comparison, which included the first nationally representative data for asthma control in NZ, showed that poorly controlled asthma is common in both NZ and AU, despite subsidized ICS-containing medications. The greater use of ICS-alone in NZ relative to ICS/LABA does not appear to have compromised population-level asthma outcomes, perhaps due to better adherence in NZ. Different ICS/LABA subsidy criteria and different patient copayments may also have contributed to these findings. © 2017 Asian Pacific Society of Respirology.
Expanding Combat Power Through Military Cyberpower Theory
2015-04-02
systems (ICS) and supervisory control and data acquisition systems ( SCADA ) are public-facing, providing more avenues of approach for an adversary. ICS...and SCADA are the two primary means for cyber adversaries to achieve direct physical effects through cyberspace. Strategic Attribution. From a...REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to
Balashov, A M; Selishchev, S V
2004-01-01
An integral chip (IC) was designed for controlling the step-down pulse voltage converter, which is based on the multiphase pulse-duration modulation, for use in biomedical microprocessor systems. The CMOS technology was an optimal basis for the IC designing. An additional feedback circuit diminishes the output voltage dispersion at dynamically changing loads.
Smy, Laura; Shaw, Kaitlyn; Amstutz, Ursula; Staub, Michelle; Chaudhry, Shahnaz; Smith, Anne; Carleton, Bruce; Koren, Gideon
2018-06-01
Inhaled corticosteroids (ICS) are the recommended long-term control therapy for asthma in children. However, concern exists regarding potential adrenal suppression with chronic ICS use. Our pilot study reported that hair cortisol in children was 50% lower during ICS therapy than prior to therapy, suggestive of adrenal suppression. To evaluate hair cortisol concentration (HCC) as a potential biomarker for possible adrenal suppression from ICS use in children with asthma. A retrospective observational study was performed at asthma clinics in Vancouver, Winnipeg, and Toronto, Canada. Children (n = 586) were recruited from July 2012 to December 2014 inclusive of those without asthma, with asthma not using ICS, and with asthma using ICS. The most recent three-month HCC was measured by enzyme immunoassay and compared among the groups. Quantile regression analysis was performed to identify factors potentially affecting HCC. The median HCC was not significantly different among the children: No ICS (n = 47, 6.7 ng/g, interquartile range (IQR) 3.7-9.8 ng/g), ICS Treated (n = 360, 6.5 ng/g, IQR 3.8-14.3 ng/g), and Controls (n = 53, 5.8 ng/g, IQR 4.6-16.7 ng/g). 5.6% of the children using ICS had hair cortisol <2.0 ng/g compared to none in the control groups (P < .05, comparing ICS Treated (20/360) to all Controls combined (0/100)) and only half had been exposed to systemic corticosteroids. Age, sex, BMI, and intranasal corticosteroid use were significantly associated with HCC. Results suggest HCC may be a potential biomarker for adrenal suppression as a population of children using ICS with HCC < 2.0 ng/g was identified compared to none in the control groups. Further research is needed to determine if those children have or are at risk of adrenal suppression or insufficiency. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
[Infection control and safety culture in German hospitals].
Hansen, Sonja; Schwab, Frank; Gropmann, Alexander; Behnke, Michael; Gastmeier, Petra
2016-07-01
Healthcare-associated infections (HAI) are the most frequent adverse events in the healthcare setting and their prevention is an important contribution to patient safety in hospitals. To analyse to what extent safety cultural aspects with relevance to infection control are implemented in German hospitals. Safety cultural aspects of infection control were surveyed with an online questionnaire; data were analysed descriptively. Data from 543 hospitals with a median of [IQR] 275 [157; 453] beds were analysed. Almost all hospitals (96.6 %) had internal guidelines for infection control (IC) in place; 82 % defined IC objectives, most often regarding hand hygiene (HH) (93 %) and multidrug resistant organisms (72 %) and less frequently for antibiotic stewardship (48 %) or prevention of specific HAI. In 94 % of hospitals, a reporting system for adverse events was in place, which was also used to report low compliance with HH, outbreaks and Clostridium difficile-associated infections. Members of the IC team were most often seen to hold daily responsibility for IC in the hospital, but rarely other hospital staff (94 versus 19 %). Safety cultural aspects are not fully implemented in German hospitals. IC should be more strongly implemented in healthcare workers' daily routine and more visibly supported by hospital management.
A packet switched communications system for GRO
NASA Astrophysics Data System (ADS)
Husain, Shabu; Yang, Wen-Hsing; Vadlamudi, Rani; Valenti, Joseph
1993-11-01
This paper describes the packet switched Instrumenters Communication System (ICS) that was developed for the Command Management Facility at GSFC to support the Gamma Ray Observatory (GRO) spacecraft. The GRO ICS serves as a vital science data acquisition link to the GRO scientists to initiate commands for their spacecraft instruments. The system is ready to send and receive messages at any time, 24 hours a day and seven days a week. The system is based on X.25 and the International Standard Organization's (ISO) 7-layer Open Systems Interconnection (OSI) protocol model and has client and server components. The components of the GRO ICS are discussed along with how the Communications Subsystem for Interconnection (CSFI) and Network Control Program Packet Switching Interface (NPSI) software are used in the system.
The timing of control signals underlying fast point-to-point arm movements.
Ghafouri, M; Feldman, A G
2001-04-01
It is known that proprioceptive feedback induces muscle activation when the facilitation of appropriate motoneurons exceeds their threshold. In the suprathreshold range, the muscle-reflex system produces torques depending on the position and velocity of the joint segment(s) that the muscle spans. The static component of the torque-position relationship is referred to as the invariant characteristic (IC). According to the equilibrium-point (EP) hypothesis, control systems produce movements by changing the activation thresholds and thus shifting the IC of the appropriate muscles in joint space. This control process upsets the balance between muscle and external torques at the initial limb configuration and, to regain the balance, the limb is forced to establish a new configuration or, if the movement is prevented, a new level of static torques. Taken together, the joint angles and the muscle torques generated at an equilibrium configuration define a single variable called the EP. Thus by shifting the IC, control systems reset the EP. Muscle activation and movement emerge following the EP resetting because of the natural physical tendency of the system to reach equilibrium. Empirical and simulation studies support the notion that the control IC shifts and the resulting EP shifts underlying fast point-to-point arm movements are gradual rather than step-like. However, controversies exist about the duration of these shifts. Some studies suggest that the IC shifts cease with the movement offset. Other studies propose that the IC shifts end early in comparison to the movement duration (approximately, at peak velocity). The purpose of this study was to evaluate the duration of the IC shifts underlying fast point-to-point arm movements. Subjects made fast (hand peak velocity about 1.3 m/s) planar arm movements toward different targets while grasping a handle. Hand forces applied to the handle and shoulder/elbow torques were, respectively, measured from a force sensor placed on the handle, or computed with equations of motion. In some trials, an electromagnetic brake prevented movements. In such movements, the hand force and joint torques reached a steady state after a time that was much smaller than the movement duration in unobstructed movements and was approximately equal to the time to peak velocity (mean difference < 80 ms). In an additional experiment, subjects were instructed to rapidly initiate corrections of the pushing force in response to movement arrest. They were able to initiate such corrections only when the joint torques and the pushing force had practically reached a steady state. The latency of correction onset was, however, smaller than the duration of unobstructed movements. We concluded that during the time at which the steady state torques were reached, the control pattern of IC shifts remained the same despite the movement block. Thereby the duration of these shifts did not exceed the time of reaching the steady state torques. Our findings are consistent with the hypothesis that, in unobstructed movements, the IC shifts and resulting shifts in the EP end approximately at peak velocity. In other words, during the latter part of the movement, the control signals responsible for the equilibrium shift remained constant, and the movement was driven by the arm inertial, viscous and elastic forces produced by the muscle-reflex system. Fast movements may thus be completed without continuous control guidance. As a consequence, central corrections and sequential commands may be issued rapidly, without waiting for the end of kinematic responses to each command, which may be important for many motor behaviours including typing, piano playing and speech. Our study also illustrates that the timing of the control signals may be substantially different from that of the resulting motor output and that the same control pattern may produce different motor outputs depending on external conditions.
Quinn, Emma; Johnstone, Travers; Najjar, Zeina; Cains, Toni; Tan, Geoff; Huhtinen, Essi; Nilsson, Sven; Burgess, Stuart; Dunn, Matthew; Gupta, Leena
2017-09-05
The incident command system (ICS) provides a common structure to control and coordinate an emergency response, regardless of scale or predicted impact. The lessons learned from the application of an ICS for large infectious disease outbreaks are documented. However, there is scant evidence on the application of an ICS to manage a local multiagency response to a disease cluster with environmental health risks. The Sydney Local Health District Public Health Unit (PHU) in New South Wales, Australia, was notified of 5 cases of Legionnaires' disease during 2 weeks in May 2016. This unusual incident triggered a multiagency investigation involving an ICS with staff from the PHU, 3 local councils, and the state health department to help prevent any further public health risk. The early and judicious use of ICS enabled a timely and effective response by supporting clear communication lines between the incident controller and field staff. The field team was key in preventing any ongoing public health risk through inspection, sampling, testing, and management of water systems identified to be at-risk for transmission of legionella. Good working relationships between partner agencies and trust in the technical proficiency of environmental health staff aided in the effective management of the response. (Disaster Med Public Health Preparedness. 2017;page 1 of 4).
Industrial Control Systems/SCADA systems risk assessment in the energy sector
NASA Astrophysics Data System (ADS)
Falodun, Babatunde
The energy sector is one of the most critical components of our national infrastructure. It not only provides the electrical power and petroleum required to run day-to-day operations and mechanisms in society, it's also an important element that directly impacts the economy with regard to growth and stability. Industrial Control Systems (ICS) /Supervisory Control and Data Acquisition Systems (SCADA) are computerized mechanisms, they are both software and hardware that are used to control real time processes and operations in power plants and oil production facilities. A significant attack on these control systems that leads to widespread disruption of energy could result in catastrophic consequences for any major city and even the nation. This research paper explores cyber threats and vulnerabilities faced by ICS/SCADA systems in the energy sector and also highlights possible outcomes of a successful breach. Furthermore, the research underscores mitigation strategies that could be used to prevent and respond to an attack. Keywords: Cybersecurity, SCADA, Cyber Attacks, Threats, Vulnerabilities, Risk Assessment, Dr. Albert Orbinati.
Numerical Simulation of Measurements during the Reactor Physical Startup at Unit 3 of Rostov NPP
NASA Astrophysics Data System (ADS)
Tereshonok, V. A.; Kryakvin, L. V.; Pitilimov, V. A.; Karpov, S. A.; Kulikov, V. I.; Zhylmaganbetov, N. M.; Kavun, O. Yu.; Popykin, A. I.; Shevchenko, R. A.; Shevchenko, S. A.; Semenova, T. V.
2017-12-01
The results of numerical calculations and measurements of some reactor parameters during the physical startup tests at unit 3 of Rostov NPP are presented. The following parameters are considered: the critical boron acid concentration and the currents from ionization chambers (IC) during the scram system efficiency evaluation. The scram system efficiency was determined using the inverse point kinetics equation with the measured and simulated IC currents. The results of steady-state calculations of relative power distribution and efficiency of the scram system and separate groups of control rods of the control and protection system are also presented. The calculations are performed using several codes, including precision ones.
α-Intercalated cells defend the urinary system from bacterial infection.
Paragas, Neal; Kulkarni, Ritwij; Werth, Max; Schmidt-Ott, Kai M; Forster, Catherine; Deng, Rong; Zhang, Qingyin; Singer, Eugenia; Klose, Alexander D; Shen, Tian Huai; Francis, Kevin P; Ray, Sunetra; Vijayakumar, Soundarapandian; Seward, Samuel; Bovino, Mary E; Xu, Katherine; Takabe, Yared; Amaral, Fábio E; Mohan, Sumit; Wax, Rebecca; Corbin, Kaitlyn; Sanna-Cherchi, Simone; Mori, Kiyoshi; Johnson, Lynne; Nickolas, Thomas; D'Agati, Vivette; Lin, Chyuan-Sheng; Qiu, Andong; Al-Awqati, Qais; Ratner, Adam J; Barasch, Jonathan
2014-07-01
α-Intercalated cells (A-ICs) within the collecting duct of the kidney are critical for acid-base homeostasis. Here, we have shown that A-ICs also serve as both sentinels and effectors in the defense against urinary infections. In a murine urinary tract infection model, A-ICs bound uropathogenic E. coli and responded by acidifying the urine and secreting the bacteriostatic protein lipocalin 2 (LCN2; also known as NGAL). A-IC-dependent LCN2 secretion required TLR4, as mice expressing an LPS-insensitive form of TLR4 expressed reduced levels of LCN2. The presence of LCN2 in urine was both necessary and sufficient to control the urinary tract infection through iron sequestration, even in the harsh condition of urine acidification. In mice lacking A-ICs, both urinary LCN2 and urinary acidification were reduced, and consequently bacterial clearance was limited. Together these results indicate that A-ICs, which are known to regulate acid-base metabolism, are also critical for urinary defense against pathogenic bacteria. They respond to both cystitis and pyelonephritis by delivering bacteriostatic chemical agents to the lower urinary system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, Roger A; Melin, Alexander M; Burress, Timothy A
The overall project objective is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant components. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration vehicle. The project s focus is not primarily on pump design, but instead is on methods to deeply embed I&C within a pump system. However, because the I&C is intimately part of the basic millisecond-by-millisecond functioning of the pump, the I&C design cannot proceed in isolation from the other aspects of the pump. The pumpmore » will not function if the characteristics of the I&C are not embedded within the design because the I&C enables performance of the basic function rather than merely monitoring quasi-stable performance. Traditionally, I&C has been incorporated in nuclear power plant (NPP) components after their design is nearly complete; adequate performance was obtained through over-design. This report describes the progress and status of the project and provides a conceptual design overview for the embedded I&C pump.« less
Characterization of indigenous chicken production systems in Rwanda.
Mahoro, J; Muasya, T K; Mbuza, F; Habimana, R; Kahi, A K
2017-12-01
Characterization of indigenous chicken (IC) production systems in Rwanda was conducted from November 2015 to January 2016 with the aim of understanding socio-economic characteristics, management of IC, production parameters, feed resources, and constraints faced by farmers rearing IC. A survey involving 206 households was carried out in 5 districts with the highest populations of IC using structured questionnaires. Data were analyzed using SAS software. The results showed that the majority of respondents (62.4%) were males and 37.6% were females. The majority of respondents (83.6%) had formal education. All family members were involved in the chicken husbandry practices. However, women (78%) were highly responsible for IC management activities. The family size averaged 5 persons (ranging 2 to 13) per household. Land was privately owned by farmers (84%) with a mean holding of 0.87 ha per household. The production system was mainly extensive with minimum provision of supplementary feeds. Chickens were being housed in separate houses at night and mating was uncontrolled. Breeding and replacement stocks were mainly sourced from the hatching of eggs using broody hens (60.68% of respondents). There were no vaccination programs, and ecto- and endo-parasites control was done when need arose. Egg production, income generation, meat production, and production of breeding stock were the main reasons of keeping IC. The first 3 main challenges facing IC production were diseases outbreaks, lack of investment capital, and predators. Others challenges, such as feed shortage, thieves, fluctuation of market price, lack of information on poultry rearing, and lack of chicken houses, also were mentioned. The IC production constraints mentioned need urgent mitigation measures to sustain utilization of IC against the changing climatic and economic conditions. Therefore, individual, public institution, and non-governmental organization efforts are required to develop sustainable breeding objectives directed to functions of IC and production challenges faced in the systems. © 2017 Poultry Science Association Inc.
Toward Automating Web Protocol Configuration for a Programmable Logic Controller Emulator
2014-06-19
Security Risks for Industrial Control Systems ,” VDE 2004 Congress, Berlin, Germany, October 2004, pp. 1-7. [Cis12] Cisco, NetFlow Configuration Guide...Date 29 May 2014 Date AFIT-ENG-T-14-J-4 Abstract Industrial Control Systems (ICS) remain vulnerable through attack vectors that exist within programmable...5 2.2 Industrial Control Systems
Detecting Payload Attacks on Programmable Logic Controllers (PLCs)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Huan
Programmable logic controllers (PLCs) play critical roles in industrial control systems (ICS). Providing hardware peripherals and firmware support for control programs (i.e., a PLC’s “payload”) written in languages such as ladder logic, PLCs directly receive sensor readings and control ICS physical processes. An attacker with access to PLC development software (e.g., by compromising an engineering workstation) can modify the payload program and cause severe physical damages to the ICS. To protect critical ICS infrastructure, we propose to model runtime behaviors of legitimate PLC payload program and use runtime behavior monitoring in PLC firmware to detect payload attacks. By monitoring themore » I/O access patterns, network access patterns, as well as payload program timing characteristics, our proposed firmware-level detection mechanism can detect abnormal runtime behaviors of malicious PLC payload. Using our proof-of-concept implementation, we evaluate the memory and execution time overhead of implementing our proposed method and find that it is feasible to incorporate our method into existing PLC firmware. In addition, our evaluation results show that a wide variety of payload attacks can be effectively detected by our proposed approach. The proposed firmware-level payload attack detection scheme complements existing bumpin- the-wire solutions (e.g., external temporal-logic-based model checkers) in that it can detect payload attacks that violate realtime requirements of ICS operations and does not require any additional apparatus.« less
A design procedure for fan inflow control structures
NASA Technical Reports Server (NTRS)
Gedge, M. R.
1980-01-01
Significant differences exist in the noise generated by engine in flight and engines operating on the test stand. It was observed that these differences can be reduced by use of an inflow control structure (ICS) in the static test configuration. The results of the second phase of a three phase program are described and the results of a test program conducted to assess and modify various theoretical models, leading to the development of an ICS design system is summarized.
Ham, Dong Yeub; Choi, Woo Suk; Song, Sang Hoon; Ahn, Young-Joon; Park, Hyoung Keun; Kim, Hyeong Gon
2016-01-01
Purpose The aim of this study was to evaluate the efficacy of a multimedia informed consent (IC) presentation on the understanding and satisfaction of patients who were scheduled to receive 120-W green-light high-performance system photoselective vaporization of the prostate (HPS-PVP). Materials and Methods A multimedia IC (M-IC) presentation for HPS-PVP was developed. Forty men with benign prostatic hyperplasia who were scheduled to undergo HPS-PVP were prospectively randomized to a conventional written IC group (W-IC group, n=20) or the M-IC group (n=20). The allocated IC was obtained by one certified urologist, followed by a 15-question test (maximum score, 15) to evaluate objective understanding, and questionnaires on subjective understanding (range, 0~10) and satisfaction (range, 0~10) using a visual analogue scale. Results Demographic characteristics, including age and the highest level of education, did not significantly differ between the two groups. No significant differences were found in scores reflecting the objective understanding of HPS-PVP (9.9±2.3 vs. 10.6±2.8, p=0.332) or in subjective understanding scores (7.5±2.1 vs. 8.6±1.7, p=0.122); however, the M-IC group showed higher satisfaction scores than the W-IC group (7.4±1.7 vs. 8.4±1.5, p=0.033). After adjusting for age and educational level, the M-IC group still had significantly higher satisfaction scores. Conclusions M-IC did not enhance the objective knowledge of patients regarding this surgical procedure. However, it improved the satisfaction of patients with the IC process itself. PMID:27169129
Vibrational energy flow controls internal conversion in a transition metal complex.
Hedley, Gordon J; Ruseckas, Arvydas; Samuel, Ifor D W
2010-09-02
Internal conversion (IC) between excited electronic states is a fundamental photophysical process that is important for understanding protection from UV radiation, energy transfer pathways and electron injection in artificial photosynthetic systems and organic solar cells. We have studied IC between three singlet MLCT states in an iridium complex using femtosecond fluorescence spectroscopy. Very fast IC with a time constant of <20 fs is observed from the highest state and a much slower relaxation to the lowest energy singlet state on a 70 fs time scale. The abrupt slowdown of the relaxation rate occurs when there is >0.6 eV of vibrational energy stored in the complex that has to be dissipated by intramolecular vibrational redistribution before further IC to the lower energy states can occur. These results show that the ability to dissipate vibrational energy can control the relaxation process in this class of materials.
Ultra-precision engineering in lithographic exposure equipment for the semiconductor industry.
Schmidt, Robert-H Munnig
2012-08-28
The developments in lithographic tools for the production of an integrated circuit (IC) are ruled by 'Moore's Law': the density of components on an IC doubles in about every two years. The corresponding size reduction of the smallest detail in an IC entails several technological breakthroughs. The wafer scanner, the exposure system that defines those details, is the determining factor in these developments. This review deals with those aspects of the positioning systems inside these wafer scanners that enable the extension of Moore's Law into the future. The design of these systems is increasingly difficult because of the accuracy levels in the sub-nanometre range coupled with motion velocities of several metres per second. In addition to the use of feedback control for the reduction of errors, high-precision model-based feed-forward control is required with an almost ideally reproducible motion-system behaviour and a strict limitation of random disturbing events. The full mastering of this behaviour even includes material drift on an atomic scale and is decisive for the future success of these machines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Havarinasab, S.; Hultman, P.
Inorganic mercury may aggravate murine systemic autoimmune diseases which are either spontaneous (genetically determined) or induced by non-genetic mechanisms. Organic mercury species, the dominating form of mercury exposure in the human population, have not been examined in this respect. Therefore, ethyl mercury in the form of thimerosal, a preservative recently debated as a possible health hazard when present in vaccines, was administered in a dose of 0.156-5 mg/L drinking water to female (NZB x NZW)F1 (ZBWF1) mice. These mice develop an age-dependent spontaneous systemic autoimmune disease with high mortality primarily due to immune-complex (IC) glomerulonephritis. Five mg thimerosal/L drinking watermore » (295 {mu}g Hg/kg body weight (bw)/day) for 7 weeks induced glomerular, mesangial and systemic vessel wall IC deposits and antinuclear antibodies (ANA) which were not present in the untreated controls. After 22-25 weeks, the higher doses of thimerosal had shifted the localization of the spontaneously developing renal glomerular IC deposits from the capillary wall position seen in controls to the mesangium. The altered localization was associated with less severe histological kidney damage, less proteinuria, and reduced mortality. The effect was dose-dependent, lower doses having no effect compared with the untreated controls. A different effect of thimerosal treatment was induction of renal and splenic vessel walls IC deposits. Renal vessel wall deposits occurred at a dose of 0.313-5 mg thimerosal/L (18-295 {mu}g Hg/kg bw/day), while splenic vessel wall deposits developed also in mice given the lowest dose of thimerosal, 0.156 mg/L (9 {mu}g Hg/kg bw/day). The latter dose is 3- and 15-fold lower than the dose of Hg required to induce vessel wall IC deposits in genetically susceptible H-2 {sup s} mice by HgCl{sub 2} and thimerosal, respectively. Further studies on the exact conditions needed for induction of systemic IC deposits by low-dose organic mercurials in autoimmune-prone individuals, as well as the potential effect of these deposits on the vessel walls, are warranted.« less
76 FR 82079 - AP1000 Design Certification Amendment
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-30
... reference Revision 15 of the design control document (DCD) (ADAMS Accession No. ML053460400), which... to DAC in the areas of piping design (Chapter 3), instrumentation and control (I&C) systems (Chapter... Systems Manual, as described in the AP1000 Design Control Document, Revision 17, meets the criteria of...
Infection control challenges in deployed US military treatment facilities.
Hospenthal, Duane R; Crouch, Helen K
2009-04-01
Personnel sustaining combat-related injuries in current overseas conflicts continue to have their care complicated by infections caused by multidrug-resistant organisms, including Acinetobacter, Klebsiella, and Pseudomonas. Although presumed to be due to multiple factors both within and outside of the combat theater, concern has been raised about the difficulties in establishing and maintaining standard infection control (IC) practices in deployed medical treatment facilities and in the evacuation of the injured back to the United States. Level III facilities (hospitals capable of holding patients >72 hours) in Iraq and Afghanistan and the evacuation system from Iraq to the continental US were reviewed by an expert IC-infectious disease team. All reviewed facilities had established IC programs, but these were staffed by personnel with limited IC experience, often without perceived adequate time dedicated to perform their duties, and without uniform levels of command emphasis or support. Proper hand hygiene between patients was not always ideal. Isolation and cohorting of patients to decrease multidrug-resistant organism colonization and infection varied among facilities. Review of standard operating procedures found variability among institutions and in quality of these documents. Application of US national and theater-specific guidelines and of antimicrobial control measures also varied among facilities. Effective IC practices are often difficult to maintain in modern US hospitals. In the deployed setting, with ever-changing personnel in a less than optimal practice environment, IC is even more challenging. Standardization of practice with emphasis on the basics of IC practice (e.g., hand hygiene and isolation procedures) needs to be emplaced and maintained in the deployed setting.
Beaumont, Eric; Salavatian, Siamak; Southerland, E Marie; Vinet, Alain; Jacquemet, Vincent; Armour, J Andrew; Ardell, Jeffrey L
2013-01-01
The aims of the study were to determine how aggregates of intrinsic cardiac (IC) neurons transduce the cardiovascular milieu versus responding to changes in central neuronal drive and to determine IC network interactions subsequent to induced neural imbalances in the genesis of atrial fibrillation (AF). Activity from multiple IC neurons in the right atrial ganglionated plexus was recorded in eight anaesthetized canines using a 16-channel linear microelectrode array. Induced changes in IC neuronal activity were evaluated in response to: (1) focal cardiac mechanical distortion; (2) electrical activation of cervical vagi or stellate ganglia; (3) occlusion of the inferior vena cava or thoracic aorta; (4) transient ventricular ischaemia, and (5) neurally induced AF. Low level activity (ranging from 0 to 2.7 Hz) generated by 92 neurons was identified in basal states, activities that displayed functional interconnectivity. The majority (56%) of IC neurons so identified received indirect central inputs (vagus alone: 25%; stellate ganglion alone: 27%; both: 48%). Fifty per cent transduced the cardiac milieu responding to multimodal stressors applied to the great vessels or heart. Fifty per cent of IC neurons exhibited cardiac cycle periodicity, with activity occurring primarily in late diastole into isovolumetric contraction. Cardiac-related activity in IC neurons was primarily related to direct cardiac mechano-sensory inputs and indirect autonomic efferent inputs. In response to mediastinal nerve stimulation, most IC neurons became excessively activated; such network behaviour preceded and persisted throughout AF. It was concluded that stochastic interactions occur among IC local circuit neuronal populations in the control of regional cardiac function. Modulation of IC local circuit neuronal recruitment may represent a novel approach for the treatment of cardiac disease, including atrial arrhythmias. PMID:23818689
NASA Astrophysics Data System (ADS)
Gladwin, D.; Stewart, P.; Stewart, J.
2011-02-01
This article addresses the problem of maintaining a stable rectified DC output from the three-phase AC generator in a series-hybrid vehicle powertrain. The series-hybrid prime power source generally comprises an internal combustion (IC) engine driving a three-phase permanent magnet generator whose output is rectified to DC. A recent development has been to control the engine/generator combination by an electronically actuated throttle. This system can be represented as a nonlinear system with significant time delay. Previously, voltage control of the generator output has been achieved by model predictive methods such as the Smith Predictor. These methods rely on the incorporation of an accurate system model and time delay into the control algorithm, with a consequent increase in computational complexity in the real-time controller, and as a necessity relies to some extent on the accuracy of the models. Two complementary performance objectives exist for the control system. Firstly, to maintain the IC engine at its optimal operating point, and secondly, to supply a stable DC supply to the traction drive inverters. Achievement of these goals minimises the transient energy storage requirements at the DC link, with a consequent reduction in both weight and cost. These objectives imply constant velocity operation of the IC engine under external load disturbances and changes in both operating conditions and vehicle speed set-points. In order to achieve these objectives, and reduce the complexity of implementation, in this article a controller is designed by the use of Genetic Programming methods in the Simulink modelling environment, with the aim of obtaining a relatively simple controller for the time-delay system which does not rely on the implementation of real time system models or time delay approximations in the controller. A methodology is presented to utilise the miriad of existing control blocks in the Simulink libraries to automatically evolve optimal control structures.
Gregory, Shaun D; Stevens, Michael C; Pauls, Jo P; Schummy, Emma; Diab, Sara; Thomson, Bruce; Anderson, Ben; Tansley, Geoff; Salamonsen, Robert; Fraser, John F; Timms, Daniel
2016-09-01
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
CARMENES. IV: instrument control software
NASA Astrophysics Data System (ADS)
Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Hagen, Hans-Jürgen; Morales, Rafael; Abril, Miguel; Galadí-Enríquez, David; Seifert, Walter; Sánchez Carrasco, Miguel A.; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, Jose A.; Mandel, Holger
2012-09-01
The overall purpose of the CARMENES instrument is to perform high-precision measurements of radial velocities of late-type stars with long-term stability. CARMENES will be installed in 2014 at the 3.5 m telescope in the German- Spanish Astronomical Center at Calar Alto observatory (CAHA, Spain) and will be equipped with two spectrographs in the near-infrared and visible windows. The technology involved in such instrument represents a challenge at all levels. The instrument coordination and management is handled by the Instrument Control System (ICS), which is responsible of carrying out the operations of the different subsystems and providing a tool to operate the instrument from low to high user interaction level. The main goal of the ICS and the CARMENES control layer architecture is to maximize the instrument efficiency by reducing time overheads and by operating it in an integrated manner. The ICS implements the CARMENES operational design. A description of the ICS architecture and the application programming interfaces for low- and high-level communication is given. Internet Communications Engine is the technology selected to implement most of the interface protocols.
α–Intercalated cells defend the urinary system from bacterial infection
Paragas, Neal; Kulkarni, Ritwij; Werth, Max; Schmidt-Ott, Kai M.; Forster, Catherine; Deng, Rong; Zhang, Qingyin; Singer, Eugenia; Klose, Alexander D.; Shen, Tian Huai; Francis, Kevin P.; Ray, Sunetra; Vijayakumar, Soundarapandian; Seward, Samuel; Bovino, Mary E.; Xu, Katherine; Takabe, Yared; Amaral, Fábio E.; Mohan, Sumit; Wax, Rebecca; Corbin, Kaitlyn; Sanna-Cherchi, Simone; Mori, Kiyoshi; Johnson, Lynne; Nickolas, Thomas; D’Agati, Vivette; Lin, Chyuan-Sheng; Qiu, Andong; Al-Awqati, Qais; Ratner, Adam J.; Barasch, Jonathan
2014-01-01
α–Intercalated cells (A-ICs) within the collecting duct of the kidney are critical for acid-base homeostasis. Here, we have shown that A-ICs also serve as both sentinels and effectors in the defense against urinary infections. In a murine urinary tract infection model, A-ICs bound uropathogenic E. coli and responded by acidifying the urine and secreting the bacteriostatic protein lipocalin 2 (LCN2; also known as NGAL). A-IC–dependent LCN2 secretion required TLR4, as mice expressing an LPS-insensitive form of TLR4 expressed reduced levels of LCN2. The presence of LCN2 in urine was both necessary and sufficient to control the urinary tract infection through iron sequestration, even in the harsh condition of urine acidification. In mice lacking A-ICs, both urinary LCN2 and urinary acidification were reduced, and consequently bacterial clearance was limited. Together these results indicate that A-ICs, which are known to regulate acid-base metabolism, are also critical for urinary defense against pathogenic bacteria. They respond to both cystitis and pyelonephritis by delivering bacteriostatic chemical agents to the lower urinary system. PMID:24937428
DOE Office of Scientific and Technical Information (OSTI.GOV)
Satogata, Todd
2013-04-22
The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED databasemore » management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiao; Gao, Wenzhong; Scholbrock, Andrew
To mitigate the degraded power system inertia and undesirable primary frequency response caused by large-scale wind power integration, the frequency support capabilities of variable-speed wind turbines is studied in this work. This is made possible by controlled inertial response, which is demonstrated on a research turbine - controls advanced research turbine, 3-bladed (CART3). Two distinct inertial control (IC) methods are analysed in terms of their impacts on the grids and the response of the turbine itself. The released kinetic energy in the IC methods are determined by the frequency measurement or shaped active power reference in the turbine speed-power plane.more » The wind turbine model is based on the high-fidelity turbine simulator fatigue, aerodynamic, structures and turbulence, which constitutes the aggregated wind power plant model with the simplified power converter model. The IC methods are implemented over the baseline CART3 controller, evaluated in the modified 9-bus and 14-bus testing power grids considering different wind speeds and different wind power penetration levels. The simulation results provide various insights on designing such kinds of ICs. The authors calculate the short-term dynamic equivalent loads and give a discussion about the turbine structural loadings related to the inertial response.« less
Lee, Ming-Huei; Wu, Huei-Ching; Tseng, Chien-Ming; Ko, Tsung-Liang; Weng, Tang-Jun; Chen, Yung-Fu
2018-06-10
To assess effectiveness of the video-based m-health system providing videos dictated by physicians for health education and symptom self-management for patients with IC/BPS. An m-health system was designed to provide videos for weekly health education and symptom flare self-management. O'Leary-Sant index and VAS scale as well as SF-36 health survey were administrated to evaluate the disease severity and quality of life (QoL), respectively. A total of 60 IC/BPS patients were recruited and randomly assigned to either control group (30 patients) or study group (30 patients) in sequence depending on their orders to visit our urological clinic. Patients in both control and study groups received regular treatments, while those in the study group received additional video-based intervention. Statistical analyses were conducted to compare the outcomes between baseline and post-intervention for both groups. The outcomes of video-based intervention were also compared with the text-based intervention conducted in our previous study. After video-based intervention, patients in the study group exhibited significant effect manifested in all disease severity and QoL assessments except the VAS pain scale, while no significance was found in the control group. Moreover, the study group exhibited more significant net improvements than the control group in 7 SF-36 constructs, except the mental health. The limitations include short intervention duration (8 weeks) and different study periods between text-based and video-based interventions. Video-based intervention is effective in improving the QoL of IC/BPS patients and outperforms the text-based intervention even in a short period of intervention. Copyright © 2018. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Alpi, Danielle Marie
The 16 sectors of critical infrastructure in the US are susceptible to cyber-attacks. Potential attacks come from internal and external threats. These attacks target the industrial control systems (ICS) of companies within critical infrastructure. Weakness in the energy sector's ICS, specifically the oil and gas industry, can result in economic and ecological disaster. The purpose of this study was to establish means for oil companies to identify and stop cyber-attacks specifically APT threats. This research reviewed current cyber vulnerabilities and ways in which a cyber-attack may be deterred. This research found that there are insecure devices within ICS that are not regularly updated. Therefore, security issues have amassed. Safety procedures and training thereof are often neglected. Jurisdiction is unclear in regard to critical infrastructure. The recommendations this research offers are further examination of information sharing methods, development of analytic platforms, and better methods for the implementation of defense-in-depth security measures.
New combination treatments in the management of asthma: focus on fluticasone/vilanterol
Tan, Laren D; Chan, Andrew L; Albertson, Timothy E
2014-01-01
Despite the 2007 National Asthma Education and Prevention Program Expert Panel 3 guidelines for the treatment of uncontrolled asthma, many patients with poorly controlled asthma still continue to tax the health care system. Controlling asthma symptoms and preventing acute exacerbations have been the foundation of care. Using long-term controller treatments such as inhaled corticosteroids (ICS) and inhaled long-acting beta2-agonists (LABAs) is a common approach. While patient responses to recommended pharmacotherapy may vary, poor adherence to therapy also contributes to poor asthma control. A once-daily combination inhaler, such as fluticasone furoate, an ICS, in combination with vilanterol, a LABA, offers increased convenience and potential improved adherence, which should result in enhanced clinical outcomes and reduced exacerbations. The ICS/LABA combination inhaler of fluticasone furoate and vilanterol is currently approved in the United States for use in the maintenance of chronic obstructive pulmonary disease and to reduce exacerbations. This paper reviews the expanding literature on the efficacy of fluticasone furoate and vilanterol in treating asthma. PMID:24833910
Interpretive computer simulator for the NASA Standard Spacecraft Computer-2 (NSSC-2)
NASA Technical Reports Server (NTRS)
Smith, R. S.; Noland, M. S.
1979-01-01
An Interpretive Computer Simulator (ICS) for the NASA Standard Spacecraft Computer-II (NSSC-II) was developed as a code verification and testing tool for the Annular Suspension and Pointing System (ASPS) project. The simulator is written in the higher level language PASCAL and implented on the CDC CYBER series computer system. It is supported by a metal assembler, a linkage loader for the NSSC-II, and a utility library to meet the application requirements. The architectural design of the NSSC-II is that of an IBM System/360 (S/360) and supports all but four instructions of the S/360 standard instruction set. The structural design of the ICS is described with emphasis on the design differences between it and the NSSC-II hardware. The program flow is diagrammed, with the function of each procedure being defined; the instruction implementation is discussed in broad terms; and the instruction timings used in the ICS are listed. An example of the steps required to process an assembly level language program on the ICS is included. The example illustrates the control cards necessary to assemble, load, and execute assembly language code; the sample program to to be executed; the executable load module produced by the loader; and the resulting output produced by the ICS.
Low-power analog integrated circuits for wireless ECG acquisition systems.
Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh
2012-09-01
This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.
Price, David B; Colice, Gene; Israel, Elliot; Roche, Nicolas; Postma, Dirkje S; Guilbert, Theresa W; van Aalderen, Willem M C; Grigg, Jonathan; Hillyer, Elizabeth V; Thomas, Victoria; Martin, Richard J
2016-04-01
Asthma management guidelines recommend adding a long-acting β 2 -agonist (LABA) or increasing the dose of inhaled corticosteroid (ICS) as step-up therapy for patients with uncontrolled asthma on ICS monotherapy. However, it is uncertain which option works best, which ICS particle size is most effective, and whether LABA should be administered by separate or combination inhalers. This historical, matched cohort study compared asthma-related outcomes for patients (aged 12-80 years) prescribed step-up therapy as a ≥50% extrafine ICS dose increase or add-on LABA, via either a separate inhaler or a fine-particle ICS/LABA fixed-dose combination (FDC) inhaler. Risk-domain asthma control was the primary end-point in comparisons of cohorts matched for asthma severity and control during the baseline year. After 1:2 cohort matching, the increased extrafine ICS versus separate ICS+LABA cohorts included 3232 and 6464 patients, respectively, and the fine-particle ICS/LABA FDC versus separate ICS+LABA cohorts included 7529 and 15 058 patients, respectively (overall mean age 42 years; 61-62% females). Over one outcome year, adjusted OR (95% CI) for achieving asthma control were 1.25 (1.13-1.38) for increased ICS versus separate ICS+LABA and 1.06 (1.05-1.09) for ICS/LABA FDC versus separate ICS+LABA. For patients with asthma, increased dose of extrafine-particle ICS, or add-on LABA via ICS/LABA combination inhaler, is associated with significantly better outcomes than ICS+LABA via separate inhalers.
Technical Basis for Evaluating Software-Related Common-Cause Failures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muhlheim, Michael David; Wood, Richard
2016-04-01
The instrumentation and control (I&C) system architecture at a nuclear power plant (NPP) incorporates protections against common-cause failures (CCFs) through the use of diversity and defense-in-depth. Even for well-established analog-based I&C system designs, the potential for CCFs of multiple systems (or redundancies within a system) constitutes a credible threat to defeating the defense-in-depth provisions within the I&C system architectures. The integration of digital technologies into the I&C systems provides many advantages compared to the aging analog systems with respect to reliability, maintenance, operability, and cost effectiveness. However, maintaining the diversity and defense-in-depth for both the hardware and software within themore » digital system is challenging. In fact, the introduction of digital technologies may actually increase the potential for CCF vulnerabilities because of the introduction of undetected systematic faults. These systematic faults are defined as a “design fault located in a software component” and at a high level, are predominately the result of (1) errors in the requirement specification, (2) inadequate provisions to account for design limits (e.g., environmental stress), or (3) technical faults incorporated in the internal system (or architectural) design or implementation. Other technology-neutral CCF concerns include hardware design errors, equipment qualification deficiencies, installation or maintenance errors, instrument loop scaling and setpoint mistakes.« less
Creating a meaningful infection control program: one home healthcare agency's lessons.
Poff, Renee McCoy; Browning, Sarah Via
2014-03-01
Creating a meaningful infection control program in the home care setting proved to be challenging for agency leaders of one hospital-based home healthcare agency. Challenges arose when agency leaders provided infection control (IC) data to the hospital's IC Committee. The IC Section Chief asked for national benchmark comparisons to align home healthcare reporting to that of the hospital level. At that point, it was evident that the home healthcare IC program lacked definition and structure. The purpose of this article is to share how one agency built a meaningful IC program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, C.; Joe, J.; Boring, R.
The primary objective of the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is to sustain operation of the existing commercial nuclear power plants (NPPs) through a multi-pathway approach in conducting research and development (R&D). The Advanced Instrumentation, Information, and Control (II&C) System Technologies pathway conducts targeted R&D to address aging and reliability concerns with legacy instrumentation and control (I&C) and other information systems in existing U.S. NPPs. Control room modernization is an important part following this pathway, and human factors experts at Idaho National Laboratory (INL) have been involved in conducting R&D to supportmore » migration of new digital main control room (MCR) technologies from legacy analog and legacy digital I&C. This paper describes a human factors engineering (HFE) process that supports human-system interface (HSI) design in MCR modernization activities, particularly with migration of old digital to new digital I&C. The process described in this work is an expansion from the LWRS Report INL/EXT-16-38576, and is a requirements-driven approach that aligns with NUREG-0711 requirements. The work described builds upon the existing literature by adding more detail around key tasks and decisions to make when transitioning from HSI Design into Verification and Validation (V&V). The overall objective of this process is to inform HSI design and elicit specific, measurable, and achievable human factors criteria for new digital technologies. Upon following this process, utilities should have greater confidence with transitioning from HSI design into V&V.« less
ICS-II USA research design and methodology.
Rana, H; Andersen, R M; Nakazono, T T; Davidson, P L
1997-05-01
The purpose of the WHO-sponsored International Collaborative Study of Oral Health Outcomes (ICS-II) was to provide policy-markers and researchers with detailed, reliable, and valid data on the oral health situation in their countries or regions, together with comparative data from other dental care delivery systems. ICS-II used a cross-sectional design with no explicit control groups or experimental interventions. A standardized methodology was developed and tested for collecting and analyzing epidemiological, sociocultural, economic, and delivery system data. Respondent information was obtained by household interviews, and clinical examinations were conducted by calibrated oral epidemiologists. Discussed are the sampling design characteristics for the USA research locations, response rates, samples size for interview and oral examination data, weighting procedures, and statistical methods. SUDAAN was used to adjust variance calculations, since complex sampling designs were used.
Cyber Security Audit and Attack Detection Toolkit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, Dale
2012-05-31
This goal of this project was to develop cyber security audit and attack detection tools for industrial control systems (ICS). Digital Bond developed and released a tool named Bandolier that audits ICS components commonly used in the energy sector against an optimal security configuration. The Portaledge Project developed a capability for the PI Historian, the most widely used Historian in the energy sector, to aggregate security events and detect cyber attacks.
NASA Astrophysics Data System (ADS)
McQuiddy, David N., Jr.; Sokolov, Vladimir
1990-12-01
The present conference discusses microwave filters, lightwave technology for microwave antennas, planar and quasi-planar guides, mixers and VCOs, cavity filters, discontinuity and coupling effects, control circuits, power dividers and phase shifters, microwave ICs, biological effects and medical applications, CAD and modeling for MMICs, directional couplers, MMIC design trends, microwave packaging and manufacturing, monolithic ICs, and solid-state devices and circuits. Also discussed are microwave and mm-wave superconducting technology, MICs for communication systems, the merging of optical and microwave technologies, microwave power transistors, ferrite devices, network measurements, advanced transmission-line structures, FET devices and circuits, field theory of IC discontinuities, active quasi-optical techniques, phased-array techniques and circuits, nonlinear CAD, sub-mm wave devices, and high power devices.
275 C Downhole Microcomputer System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chris Hutchens; Hooi Miin Soo
2008-08-31
An HC11 controller IC and along with serial SRAM and ROM support ICs chip set were developed to support a data acquisition and control for extreme temperature/harsh environment conditions greater than 275 C. The 68HC11 microprocessor is widely used in well logging tools for control, data acquisition, and signal processing applications and was the logical choice for a downhole controller. This extreme temperature version of the 68HC11 enables new high temperature designs and additionally allows 68HC11-based well logging tools and MWD tools to be upgraded for high temperature operation in deep gas reservoirs, The microcomputer chip consists of the microprocessormore » ALU, a small boot ROM, 4 kbyte data RAM, counter/timer unit, serial peripheral interface (SPI), asynchronous serial interface (SCI), and the A, B, C, and D parallel ports. The chip is code compatible with the single chip mode commercial 68HC11 except for the absence of the analog to digital converter system. To avoid mask programmed internal ROM, a boot program is used to load the microcomputer program from an external mask SPI ROM. A SPI RAM IC completes the chip set and allows data RAM to be added in 4 kbyte increments. The HC11 controller IC chip set is implemented in the Peregrine Semiconductor 0.5 micron Silicon-on-Sapphire (SOS) process using a custom high temperature cell library developed at Oklahoma State University. Yield data is presented for all, the HC11, SPI-RAM and ROM. The lessons learned in this project were extended to the successful development of two high temperature versions of the LEON3 and a companion 8 Kbyte SRAM, a 200 C version for the Navy and a 275 C version for the gas industry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
DiSalvo, Rick; Surovchak, Scott; Spreng, Carl
2013-07-01
Cleanup and closure of DOE's Rocky Flats Site in Colorado, which was placed on the CERCLA National Priority List in 1989, was accomplished under CERCLA, RCRA, and the Colorado Hazardous Waste Act (CHWA). The physical cleanup work was completed in late 2005 and all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Other remaining features include two landfills closed in place with covers, four groundwater treatment systems, and surface water and groundwater monitoring systems. Under the 2006 Corrective Action Decision/Record of Decision for Rocky Flats Plantmore » (US DOE) Peripheral Operable Unit and the Central Operable Unit (CAD/ROD), the response actions selected for the Central Operable Unit (OU) are institutional controls (ICs), physical controls, and continued monitoring and maintenance. The objectives of these ICs were to prevent unacceptable exposure to remaining subsurface contamination and to prevent contaminants from mobilizing to surface water and to prevent interfering with the proper functioning of the engineered components of the remedy. An amendment in 2011 of the 2006 CAD/ROD clarified the ICs to prevent misinterpretation that would prohibit work to manage and maintain the Central OU property. The 2011 amendment incorporated a protocol for a Soil Disturbance Review Plan for work subject to ICs that requires approval from the State and public notification by DOE prior to conducting approved soil-disturbing work. (authors)« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-12
... Applications for Instrumentation and Control Upgrades for Non-Power Reactors AGENCY: Nuclear Regulatory... (NRC or the Commission) is requesting public comment on Chapter 7, Section 7.3, Reactor Control System...-Power Reactors: Format and Content,'' for instrumentation and control (I&C) upgrades and NUREG-1537...
Leicht, Anthony; Crowther, Robert; Golledge, Jonathan
2015-05-18
This study examined the impact of regular supervised exercise on body fat, assessed via anthropometry, and eating patterns of peripheral arterial disease patients with intermittent claudication (IC). Body fat, eating patterns and walking ability were assessed in 11 healthy adults (Control) and age- and mass-matched IC patients undertaking usual care (n = 10; IC-Con) or supervised exercise (12-months; n = 10; IC-Ex). At entry, all groups exhibited similar body fat and eating patterns. Maximal walking ability was greatest for Control participants and similar for IC-Ex and IC-Con patients. Supervised exercise resulted in significantly greater improvements in maximal walking ability (IC-Ex 148%-170% vs. IC-Con 29%-52%) and smaller increases in body fat (IC-Ex -2.1%-1.4% vs. IC-Con 8.4%-10%). IC-Con patients exhibited significantly greater increases in body fat compared with Control at follow-up (8.4%-10% vs. -0.6%-1.4%). Eating patterns were similar for all groups at follow-up. The current study demonstrated that regular, supervised exercise significantly improved maximal walking ability and minimised increase in body fat amongst IC patients without changes in eating patterns. The study supports the use of supervised exercise to minimize cardiovascular risk amongst IC patients. Further studies are needed to examine the additional value of other lifestyle interventions such as diet modification.
Individual Differences in Inhibitory Control Skills at Three Years of Age
Watson, Amanda J.; Bell, Martha Ann
2013-01-01
Sixty-eight 3-year-old children participated in an investigation of inhibitory control (IC). Child IC was measured using various tasks in order to determine the impact on child performance of manipulating task demands. Performance on a nonverbal IC task, but not performance on more difficult motivational or traditional IC tasks, was explained by medial frontal electroencephalographic activity and by language abilities. Because of the unique relations of nonverbal IC with concurrent developmental measures, and because of its potential to predict later social problems, we conclude that it is important to include nonverbal IC measures in investigative IC batteries in early childhood. PMID:23311312
Supramolecular Systems Behavior at the Air-Water Interface. Molecular Dynamic Simulation Study.
NASA Astrophysics Data System (ADS)
Sandoval, C.; Saavedra, M.; Gargallo, L.; Radić, D.
2008-08-01
Atomistic molecular dynamics simulation (MDS) was development to investigate the structural and dynamic properties of a monolayer of supramolecular systems. The simulations were performed at room temperature, on inclusion complexes (ICs) of α-cyclodextrin (CD) with poly(ethylene-oxide)(PEO), poly(ɛ-caprolactone)(PEC) and poly(tetrahydrofuran)(PTHF). The simulations were carried out for a surface area of 30Å. The trajectories of the MDS show that the system more stable was IC-PEC, being the less stable IC-PEO. The disordered monolayer for the systems was proved by the orientation correlation function and the radial distribution function between the polar groups of ICs and the water molecules. We found that the system IC-PEC was more stable that the systems IC-PTHF and IC-PEO.
Geldenhuys, Hennie; Mearns, Helen; Miles, David J C; Tameris, Michele; Hokey, David; Shi, Zhongkai; Bennett, Sean; Andersen, Peter; Kromann, Ingrid; Hoff, Søren T; Hanekom, Willem A; Mahomed, Hassan; Hatherill, Mark; Scriba, Thomas J; van Rooyen, Michele; Bruce McClain, J; Ryall, Robert; de Bruyn, Guy
2015-07-09
New, more effective vaccines to prevent tuberculosis (TB) disease are needed urgently. H4:IC31 is an investigational vaccine that contains a fusion protein of the immunodominant antigens TB10.4 and Ag85B, formulated in IC31 adjuvant. We assessed the safety and immunogenicity of H4:IC31 in South African adults from a TB endemic setting. In this double blind, placebo controlled, phase I trial, Mycobacterium tuberculosis-uninfected, HIV-uninfected, healthy adults with a history of childhood BCG vaccination were randomly allocated to two intramuscular vaccinations with 5, 15, 50 or 150 μg H4 formulated in 500nmol IC31, two months apart. Vaccinees were followed for six months to assess safety; immunogenicity was measured by ELISpot and intracellular cytokine staining assays. Thirty-two participants received H4:IC31 and 8 received placebo. Injection site adverse events were common but mild; mild fatigue was the most common systemic adverse event. Frequencies of adverse events did not differ between dosage groups. Detectable antigen-specific CD4 T cell responses were induced by all doses of H4:IC31, but doses below 50 μg induced the highest frequencies of CD4 T cells, comprised predominantly of IFN-γ(+)TNF-α(+)IL-2(+) or TNF-α(+)IL-2(+) cells. These memory responses persisted up to the end of follow up, on study day 182. H4:IC31 demonstrated an acceptable safety profile and was immunogenic in South African adults. In this trial, the 15 μg dose appeared to induce the most optimal immune response. Copyright © 2015 Elsevier Ltd. All rights reserved.
Intelligent controller of novel design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou Qi Jian; Bai Jian Kuo
1983-01-01
This paper presents the authors attempt to combine the control engineering principle with human intelligence to form a new control algorithm. The hybrid system thus formed is both analogous and logical in actions and is called the intelligent controller (IC). With the help of cybernetics princple, the operator's intelligent action of control is programmed into the controller and the system is thus taught to act like an intelligent being within the prescribed range. Remarkable results were obtained from experiments conducted on an electronic model simulating the above mentioned system. Stability studies and system analysis are presented. 12 references.
Benefit-cost evaluation of a highway-railroad intermodal control system (ICS)
DOT National Transportation Integrated Search
2004-06-01
Improved train location information and vehicle detection combined with grade crossing controls, traveler information, and traffic management can improve safety and reduce delay for both passengers and vehicles. In addition, the possibility of pre-em...
Jiménez-Alejo, Abel; Morales-Pérez, Arcadio; Nava-Aguilera, Elizabeth; Flores-Moreno, Miguel; Apreza-Aguilar, Sinahí; Carranza-Alcaraz, Wilhelm; Cortés-Guzmán, Antonio Juan; Fernández-Salas, Ildefonso; Ledogar, Robert J; Cockcroft, Anne; Andersson, Neil
2017-05-30
The follow-up survey of a cluster-randomised controlled trial of evidence-based community mobilisation for dengue control in Nicaragua and Mexico included entomological information from the 2012 rainy and dry seasons. We used data from the Mexican arm of the trial to assess the impact of the community action on pupal production of the dengue vector Aedes aegypti in both rainy and dry seasons. Trained field workers inspected household water containers in 90 clusters and collected any pupae or larvae present for entomological examination. We calculated indices of pupae per person and pupae per household, and traditional entomological indices of container index, household index and Breteau index, and compared these between rainy and dry seasons and between intervention and control clusters, using a cluster t-test to test significance of differences. In 11,933 houses in the rainy season, we inspected 40,323 containers and found 7070 Aedes aegypti pupae. In the dry season, we inspected 43,461 containers and counted 6552 pupae. All pupae and entomological indices were lower in the intervention clusters (IC) than in control clusters (CC) in both the rainy season (RS) and the dry season (DS): pupae per container 0.12 IC and 0.24 CC in RS, and 0.10 IC and 0.20 CC in DS; pupae per household 0.46 IC and 0.82 CC in RS, and 0.41 IC and 0.83 CC in DS; pupae per person 0.11 IC and 0.19 CC in RS, and 0.10 IC and 0.20 CC in DS; household index 16% IC and 21% CC in RS, and 12.1% IC and 17.9% CC in DS; container index 7.5% IC and 11.5% CC in RS, and 4.6% IC and 7.1% CC in DS; Breteau index 27% IC and 36% CC in RS, and 19% IC and 29% CC in DS. All differences between the intervention and control clusters were statistically significant, taking into account clustering. The trial intervention led to significant decreases in pupal and conventional entomological indices in both rainy and dry seasons. ISRCTN27581154 .
A Longitudinal Analysis of Anger and Inhibitory Control in Twins from 12–36 Months of Age
Goldsmith, H. Hill
2010-01-01
Inhibitory control (IC) is a dimension of child temperament that involves the self-regulation of behavioral responses under some form of instruction or expectation. Although IC is posited to appear in toddlerhood, the voluntary control of emotions such as anger begins earlier. Little research has analyzed relations between emotional development in infancy and later emerging IC. We examined phenotypic associations and genetic and environmental influences on parent-and laboratory-assessed anger and IC in a twin sample from 12 to 36 months of age. Typically, twins with low levels of IC had high levels of anger. Behavioral genetic findings confirmed significant genetic influences on anger and IC as assessed by parents, and on lab-based anger assessments. Shared environmental factors contributed to twin similarity on lab-assessed anger and IC at 36 months. Phenotypic covariance between anger and IC was largely due to overlapping genetic factors for parent ratings, and environmental factors in the laboratory. PMID:21159093
The next generation in optical transport semiconductors: IC solutions at the system level
NASA Astrophysics Data System (ADS)
Gomatam, Badri N.
2005-02-01
In this tutorial overview, we survey some of the challenging problems facing Optical Transport and their solutions using new semiconductor-based technologies. Advances in 0.13um CMOS, SiGe/HBT and InP/HBT IC process technologies and mixed-signal design strategies are the fundamental breakthroughs that have made these solutions possible. In combination with innovative packaging and transponder/transceiver architectures IC approaches have clearly demonstrated enhanced optical link budgets with simultaneously lower (perhaps the lowest to date) cost and manufacturability tradeoffs. This paper will describe: *Electronic Dispersion Compensation broadly viewed as the overcoming of dispersion based limits to OC-192 links and extending link budgets, *Error Control/Coding also known as Forward Error Correction (FEC), *Adaptive Receivers for signal quality monitoring for real-time estimation of Q/OSNR, eye-pattern, signal BER and related temporal statistics (such as jitter). We will discuss the theoretical underpinnings of these receiver and transmitter architectures, provide examples of system performance and conclude with general market trends. These Physical layer IC solutions represent a fundamental new toolbox of options for equipment designers in addressing systems level problems. With unmatched cost and yield/performance tradeoffs, it is expected that IC approaches will provide significant flexibility in turn, for carriers and service providers who must ultimately manage the network and assure acceptable quality of service under stringent cost constraints.
Simulation of a class of hazardous situations in the ICS «INM RAS - Baltic Sea»
NASA Astrophysics Data System (ADS)
Zakharova, Natalia; Agoshkov, Valery; Aseev, Nikita; Parmuzin, Eugene; Sheloput, Tateana; Shutyaev, Victor
2017-04-01
Development of Informational Computational Systems (ICS) for data assimilation procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in mathematical modeling, theory of adjoint equations and optimal control, inverse problems, numerical methods theory, numerical algebra, scientific computing and processing of satellite data. In this work the results on the ICS development for PC-ICS "INM RAS - Baltic Sea" are presented. We discuss practical problems studied by ICS. The System includes numerical model of the Baltic Sea thermodynamics, the new oil spill model describing the propagation of a slick at the Sea surface (Agoshkov, Aseev et al., 2014) and the optimal ship route calculating block (Agoshkov, Zayachkovsky et al., 2014). The ICS is based on the INMOM numerical model of the Baltic Sea thermodynamics (Zalesny et al., 2013). It is possible to calculate main hydrodynamic parameters (temperature, salinity, velocities, sea level) using user-friendly interface of the ICS. The System includes data assimilation procedures (Agoshkov, 2003, Parmuzin, Agoshkov, 2012) and one can use the block of variational assimilation of the sea surface temperature in order to obtain main hydrodynamic parameters. Main possibilities of the ICS and several numerical experiments are presented in the work. By the problem of risk control is meant a problem of determination of optimal resources quantity which are necessary for decreasing the risk to some acceptable value. Mass of oil slick is chosen as a function of control. For the realization of the random variable the quadratic "functional of cost" is introduced. It comprises cleaning costs and deviation of damage of oil pollution from its acceptable value. The problem of minimization of this functional is solved based on the methods of optimal control and the theory of adjoint equations. The solution of this problem is explicitly found. The study was supported by the Russian Foundation for Basic Research (project 16-31-00510) and by the Russian Science Foundation (project №14-11-00609). V. I. Agoshkov, Methods of Optimal Control and Adjoint Equations in Problems of Mathematical Physics. INM RAS, Moscow, 2003 (in Russian). V. B. Zalesny, A. V. Gusev, V. O. Ivchenko, R. Tamsalu, and R. Aps, Numerical model of the Baltic Sea circulation. Russ. J. Numer. Anal. Math. Modelling 28 (2013), No. 1, 85-100. V.I. Agoshkov, A.O. Zayachkovskiy, R. Aps, P. Kujala, and J. Rytkönen. Risk theory based solution to the problem of optimal vessel route // Russian Journal of Numerical Analysis and Mathematical Modelling. 2014. Volume 29, Issue 2, Pages 69-78. Agoshkov, V., Aseev, N., Aps, R., Kujala, P., Rytkönen, J., Zalesny, V. The problem of control of oil pollution risk in the Baltic Sea // Russian Journal of Numerical Analysis and Mathematical Modelling. 2014. Volume 29, Issue 2, Pages 93-105. E. I. Parmuzin and V. I. Agoshkov, Numerical solution of the variational assimilation problem for sea surface temperature in the model of the Black Sea dynamics. Russ. J. Numer. Anal. Math. Modelling 27 (2012), No. 1, 69-94. Olof Liungman and Johan Mattsson. Scientic Documentation of Seatrack Web; physical processes, algorithms and references, 2011.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert S. Anderson; Mark Schanfein; Trond Bjornard
2011-07-01
Many critical infrastructure sectors have been investigating cyber security issues for several years especially with the help of two primary government programs. The U.S. Department of Energy (DOE) National SCADA Test Bed and the U.S. Department of Homeland Security (DHS) Control Systems Security Program have both implemented activities aimed at securing the industrial control systems that operate the North American electric grid along with several other critical infrastructure sectors (ICS). These programs have spent the last seven years working with industry including asset owners, educational institutions, standards and regulating bodies, and control system vendors. The programs common mission is tomore » provide outreach, identification of cyber vulnerabilities to ICS and mitigation strategies to enhance security postures. The success of these programs indicates that a similar approach can be successfully translated into other sectors including nuclear operations, safeguards, and security. The industry regulating bodies have included cyber security requirements and in some cases, have incorporated sets of standards with penalties for non-compliance such as the North American Electric Reliability Corporation Critical Infrastructure Protection standards. These DOE and DHS programs that address security improvements by both suppliers and end users provide an excellent model for nuclear facility personnel concerned with safeguards and security cyber vulnerabilities and countermeasures. It is not a stretch to imagine complete surreptitious collapse of protection against the removal of nuclear material or even initiation of a criticality event as witnessed at Three Mile Island or Chernobyl in a nuclear ICS inadequately protected against the cyber threat.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, K.
This document (1) summarizes the most significant findings of the ''Qualification of Advanced Instrumentation and Control (I&C) Systems'' program initiated by the Nuclear Regulatory Commission (NRC); (2) documents a comparative analysis of U.S. and European qualification standards; and (3) provides recommendations for enhancing regulatory guidance for environmental qualification of microprocessor-based safety-related systems. Safety-related I&C system upgrades of present-day nuclear power plants, as well as I&C systems of Advanced Light-Water Reactors (ALWRs), are expected to make increasing use of microprocessor-based technology. The Nuclear Regulatory Commission (NRC) recognized that the use of such technology may pose environmental qualification challenges different from current,more » analog-based I&C systems. Hence, it initiated the ''Qualification of Advanced Instrumentation and Control Systems'' program. The objectives of this confirmatory research project are to (1) identify any unique environmental-stress-related failure modes posed by digital technologies and their potential impact on the safety systems and (2) develop the technical basis for regulatory guidance using these findings. Previous findings from this study have been documented in several technical reports. This final report in the series documents a comparative analysis of two environmental qualification standards--Institute of Electrical and Electronics Engineers (IEEE) Std 323-1983 and International Electrotechnical Commission (IEC) 60780 (1998)--and provides recommendations for environmental qualification of microprocessor-based systems based on this analysis as well as on the findings documented in the previous reports. The two standards were chosen for this analysis because IEEE 323 is the standard used in the U.S. for the qualification of safety-related equipment in nuclear power plants, and IEC 60780 is its European counterpart. In addition, the IEC document was published in 1998, and should reflect any new qualification concerns, from the European perspective, with regard to the use of microprocessor-based safety systems in power plants.« less
Model Identification and Control System Design for the Lambda Unmanned Research Vehicle
1991-09-01
AD-A241 859 D T IC_ _ _ _ _ __ OCT 21921MODEL IDENTIFICATION AND CONTROL SYSTEM DESIGN FOR THE LAMBDA UNMANNED RESEARCH VEHICLE: THESIS Gerald A...23 191K MODEL IDENTIFICATION AND CONTROL SYSTEM DESIGN FOR THE LAMBDA UNMANNED RESEARCH VEHICLE THESIS Gerald A. Swift, First Lieutenant, USAF AFIT...UNMANNED RESEARCH VEHICLE THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology Air University in Partial
V&V Plan for FPGA-based ESF-CCS Using System Engineering Approach.
NASA Astrophysics Data System (ADS)
Maerani, Restu; Mayaka, Joyce; El Akrat, Mohamed; Cheon, Jung Jae
2018-02-01
Instrumentation and Control (I&C) systems play an important role in maintaining the safety of Nuclear Power Plant (NPP) operation. However, most current I&C safety systems are based on Programmable Logic Controller (PLC) hardware, which is difficult to verify and validate, and is susceptible to software common cause failure. Therefore, a plan for the replacement of the PLC-based safety systems, such as the Engineered Safety Feature - Component Control System (ESF-CCS), with Field Programmable Gate Arrays (FPGA) is needed. By using a systems engineering approach, which ensures traceability in every phase of the life cycle, from system requirements, design implementation to verification and validation, the system development is guaranteed to be in line with the regulatory requirements. The Verification process will ensure that the customer and stakeholder’s needs are satisfied in a high quality, trustworthy, cost efficient and schedule compliant manner throughout a system’s entire life cycle. The benefit of the V&V plan is to ensure that the FPGA based ESF-CCS is correctly built, and to ensure that the measurement of performance indicators has positive feedback that “do we do the right thing” during the re-engineering process of the FPGA based ESF-CCS.
Stansfield, B; Clarke, C; Dall, P; Godwin, J; Holdsworth, R; Granat, M
2015-02-01
'True cadence' is the rate of stepping during the period of stepping. 'Step accumulation' is the steps within an epoch of time (e.g. 1min). These terms have been used interchangeably in the literature. These outcomes are compared within a population with intermittent claudication (IC). Multiday, 24h stepping activity of those with IC (30) and controls (30) was measured objectively using the activPAL physical activity monitor. 'True cadence' and 'step accumulation' outcomes were calculated. Those with IC took fewer steps/d 6531±2712 than controls 8692±2945 (P=0.003). However, these steps were taken within approximately the same number of minute epochs (IC 301±100min/d; controls 300±70min/d, P=0.894) with only slightly lower true cadence (IC 69 (IQ 66,72) steps/min; controls 72 (IQ 68,76) steps/min, P=0.026), giving substantially lower step accumulation (IC 22 (IQ 19,24) steps/min; controls 30 (IQ 23,34) steps/min) (P<0.001). However, the true cadence of stepping within the blocks of the 1, 5, 20, 30 and 60min with the maximum number of steps accumulated was lower for those with IC than controls (P<0.05). Those with IC took 1300 steps fewer per day above a true cadence of 90 steps/min. True cadence and step accumulation outcomes were radically different for the outcomes examined. 'True cadence' and 'step accumulation' were not equivalent in those with IC or controls. The measurement of true cadence in the population of people with IC provides information about their stepping rate during the time they are stepping. True cadence should be used to correctly describe the rate of stepping as performed. Copyright © 2014 Elsevier B.V. All rights reserved.
WTEC monograph on instrumentation, control and safety systems of Canadian nuclear facilities
NASA Technical Reports Server (NTRS)
Uhrig, Robert E.; Carter, Richard J.
1993-01-01
This report updates a 1989-90 survey of advanced instrumentation and controls (I&C) technologies and associated human factors issues in the U.S. and Canadian nuclear industries carried out by a team from Oak Ridge National Laboratory (Carter and Uhrig 1990). The authors found that the most advanced I&C systems are in the Canadian CANDU plants, where the newest plant (Darlington) has digital systems in almost 100 percent of its control systems and in over 70 percent of its plant protection system. Increased emphasis on human factors and cognitive science in modern control rooms has resulted in a reduced workload for the operators and the elimination of many human errors. Automation implemented through digital instrumentation and control is effectively changing the role of the operator to that of a systems manager. The hypothesis that properly introducing digital systems increases safety is supported by the Canadian experience. The performance of these digital systems has been achieved using appropriate quality assurance programs for both hardware and software development. Recent regulatory authority review of the development of safety-critical software has resulted in the creation of isolated software modules with well defined interfaces and more formal structure in the software generation. The ability of digital systems to detect impending failures and initiate a fail-safe action is a significant safety issue that should be of special interest to nuclear utilities and regulatory authorities around the world.
"PHC leadership: are health centres in good hands? Perspectives from 3 districts in Malawi".
Hana, J; Maleta, K; Kirkhaug, R; Hasvold, T
2012-09-01
The study aimed to document the kinds of leadership styles are practiced at health centres (H/C) and how these styles can be explained by the contexts, characteristics of the health centre in charge (IC) and subordinate trained health staff (STHS). A well-researched leadership style model was applied, which included task, relation and change styles. This is a cross-sectional study using self-administered questionnaires in 47 H/C in 3 districts. 347 STHSs (95%) and 46 ICs (98%) responded. Questions explored background data and perceived leadership behaviour. Style items were factor analysed, and bivariate analyses and hierarchical regressions determined how styles could be explained. Two leadership styles were revealed: "Trans" style contained all relation and the majority of task and change items; "Control" style focused on health statistics (Health Management Information System), reporting and evaluation. STHS and IC had a median age/median work experience of 34/5 years and 38,5/2 years, respectively. 48% of IC reported having no management training. CHAM H/Cs had the lowest score on "Control" style. Distance to referral hospital had no impact on style scores. No contexts or STHS characteristics predicted any leadership styles. For ICs, young age and increasing work experience were significant predictors for both styles, while Nurse ICs were negative predictors for "Control style". Management training was not a significant predictor for any style. Frontline PHC leadership may be forced by situation and context to use a comprehensive style which could lack the diversity and flexibility needed for effective leadership. The missing associations between staff characteristics and leadership styles might indicate that this group is not sufficiently considered and included in leadership processes in the PHC organization. Leadership competency for the ICs seems not to be based on formal training, but substituted by young age and work experience. Health centre organization could also influence the options for leadership behaviour. In conclusion this calls for a reassessment of H/C leadership and formal leadership training.
Brusaferro, S; Cookson, B; Kalenic, S; Cooper, T; Fabry, J; Gallagher, R; Hartemann, P; Mannerquist, K; Popp, W; Privitera, G; Ruef, C; Viale, P; Coiz, F; Fabbro, E; Suetens, C; Varela Santos, C
2014-12-11
The harmonisation of training programmes for infection control and hospital hygiene (IC/HH) professionals in Europe is a requirement of the Council recommendation on patient safety. The European Centre for Disease Prevention and Control commissioned the 'Training Infection Control in Europe' project to develop a consensus on core competencies for IC/HH professionals in the European Union (EU). Core competencies were drafted on the basis of the Improving Patient Safety in Europe (IPSE) project's core curriculum (CC), evaluated by questionnaire and approved by National Representatives (NRs) for IC/HH training. NRs also re-assessed the status of IC/HH training in European countries in 2010 in comparison with the situation before the IPSE CC in 2006. The IPSE CC had been used to develop or update 28 of 51 IC/HH courses. Only 10 of 33 countries offered training and qualification for IC/HH doctors and nurses. The proposed core competencies are structured in four areas and 16 professional tasks at junior and senior level. They form a reference for standardisation of IC/HH professional competencies and support recognition of training initiatives.
Chen, I-Chun; Lee, Ming-Huei; Lin, Hsuan-Hung; Wu, Shang-Liang; Chang, Kun-Min; Lin, Hsiu-Ying
2017-05-01
Interstitial cystitis/bladder pain syndrome (IC/BPS) has several well-known comorbid psychiatric manifestations, including insomnia, anxiety, and depression. We hypothesized that somatoform disorder, which is a psychosomatic disease, can be used as a sensitive psychiatric phenotype of IC/BPS. We investigated whether somatoform disorder increases the risk of IC/BPS.A nested case-control study and a retrospective cohort study were followed up over a 12-year period (2002-2013) in the Taiwan Health Insurance Reimbursement Database. In the nested case-control study, 1612 patients with IC/BPS were matched in a 1:2 ratio to 3224 controls based on propensity scores. The odds ratio for somatoform disorder was calculated using conditional logistic regression analysis. In the retrospective cohort study, 1436 patients with somatoform disorder were matched in a 1:2 ratio to 2872 patients with nonsomatoform disorder based on propensity scores. Cox regression analysis was used to estimate the hazard ratio associated with the development of IC/BPS in patients with somatoform disorder, and the cumulative survival probability was tested using the Kaplan-Meier analysis.We found that the odds ratio for somatoform disorder was 2.46 (95% confidence interval [CI], 1.05-5.76). Although the average time until IC/BPS development in the control subjects was 11.5 ± 1.3 years, this interval was shorter in patients with somatoform disorder (6.3 ± 3.6 years). The hazard ratio for developing IC/BPS was 2.50 (95% CI 1.23-5.58); the adjusted hazard ratio was 2.26 (95% CI 1.002-5.007). The patients and controls also differed significantly in their cumulative survival probability for IC/BPS (log rank P < .05).Evidence from the nested case-control study and retrospective cohort study consistently indicated that somatoform disorder increases the risk for IC/BPS. Our study suggests that somatoform disorder can be used as a sensitive psychiatric phenotype to predict IC/BPS. Any past history of somatoform disorder should be documented while examining patients with IC/BPS.
Evaluation of the Tuberculosis Infection Control Training Center, Tajikistan, 2014–2015
Scott, C.; Mangan, J.; Tillova, Z.; Jensen, P. A.; Ahmedov, S.; Ismoilova, J.; Trusov, A.
2017-01-01
SUMMARY SETTING Training center on tuberculosis (TB) infection control (IC) for health care workers in the Central Asian Republics region. OBJECTIVE To assess the effects of TB IC training courses conducted at the Tuberculosis Infection Control Training Center in Machiton, Tajikistan. DESIGN Participants who participated in training (n = 89) during the first year of operation (April 2014–February 2015) were invited to participate in a post-training interview. RESULTS Of the 89 participants, 84 (94%) completed the interview and expressed satisfaction with the training. Eighty (95%) participants reported meeting with workplace leadership to discuss the training. Of these, 69 (85%) reported discussing changes required to meet TB IC standards. Self-reported changes in TB IC practices at work facilities post training included the creation of TB IC committees, designation of a TB IC focal person, TB IC planning, policies to separate infectious patients in waiting rooms, provision of masks for infectious patients, development of cough etiquette policies, improved glove availability, hand hygiene programs, and TB IC posters in waiting rooms. CONCLUSIONS Participant satisfaction and reported changes in TB IC activities illustrate the potential of these training courses to improve TB IC in the region. Future training courses may be tailored to specific audiences using a structured conceptual framework to impact administration, budgeting, and facilities management of TB IC practices. PMID:28399974
Postma, Dirkje S.; Dekhuijzen, Richard; van der Molen, Thys; Martin, Richard J.; van Aalderen, Wim; Roche, Nicolas; Guilbert, Theresa W.; Israel, Elliot; van Eickels, Daniela; Khalid, Javaria Mona; Herings, Ron M.C.; Overbeek, Jetty A.; Miglio, Cristiana; Thomas, Victoria; Hutton, Catherine; Hillyer, Elizabeth V.
2017-01-01
Purpose Extrafine-particle inhaled corticosteroids (ICS) have greater small airway deposition than standard fine-particle ICS. We sought to compare asthma-related outcomes after patients initiated extrafine-particle ciclesonide or fine-particle ICS (fluticasone propionate or non-extrafine beclomethasone). Methods This historical, matched cohort study included patients aged 12-60 years prescribed their first ICS as ciclesonide or fine-particle ICS. The 2 cohorts were matched 1:1 for key demographic and clinical characteristics over the baseline year. Co-primary endpoints were 1-year severe exacerbation rates, risk-domain asthma control, and overall asthma control; secondary endpoints included therapy change. Results Each cohort included 1,244 patients (median age 45 years; 65% women). Patients in the ciclesonide cohort were comparable to those in the fine-particle ICS cohort apart from higher baseline prevalence of hospitalization, gastroesophageal reflux disease, and rhinitis. Median (interquartile range) prescribed doses of ciclesonide and fine-particle ICS were 160 (160-160) µg/day and 500 (250-500) µg/day, respectively (P<0.001). During the outcome year, patients prescribed ciclesonide experienced lower severe exacerbation rates (adjusted rate ratio [95% CI], 0.69 [0.53-0.89]), and higher odds of risk-domain asthma control (adjusted odds ratio [95% CI], 1.62 [1.27-2.06]) and of overall asthma control (2.08 [1.68-2.57]) than those prescribed fine-particle ICS. The odds of therapy change were 0.70 (0.59-0.83) with ciclesonide. Conclusions In this matched cohort analysis, we observed that initiation of ICS with ciclesonide was associated with better 1-year asthma outcomes and fewer changes to therapy, despite data suggesting more difficult-to-control asthma. The median prescribed dose of ciclesonide was one-third that of fine-particle ICS. PMID:28102056
Training on Working Memory and Inhibitory Control in Young Adults
Maraver, Maria J.; Bajo, M. Teresa; Gomez-Ariza, Carlos J.
2016-01-01
Different types of interventions have focused on trying to improve Executive Functions (EFs) due to their essential role in human cognition and behavior regulation. Although EFs are thought to be diverse, most training studies have targeted cognitive processes related to working memory (WM), and fewer have focused on training other control mechanisms, such as inhibitory control (IC). In the present study, we aimed to investigate the differential impact of training WM and IC as compared with control conditions performing non-executive control activities. Young adults were divided into two training (WM/IC) and two (active/passive) control conditions. Over six sessions, the training groups engaged in three different computer-based adaptive activities (WM or IC), whereas the active control group completed a program with low control-demanding activities that mainly involved processing speed. In addition, motivation and engagement were monitored through the training. The WM-training activities required maintenance, updating and memory search processes, while those from the IC group engaged response inhibition and interference control. All participants were pre- and post-tested in criterion tasks (n-back and Stroop), near transfer measures of WM (Operation Span) and IC (Stop-Signal). Non-trained far transfer outcome measures included an abstract reasoning test (Raven’s Advanced Progressive Matrices) and a well-validated experimental task (AX-CPT) that provides indices of cognitive flexibility considering proactive/reactive control. Training results revealed that strongly motivated participants reached higher levels of training improvements. Regarding transfer effects, results showed specific patterns of near transfer effects depending on the type of training. Interestingly, it was only the IC training group that showed far transfer to reasoning. Finally, all trained participants showed a shift toward a more proactive mode of cognitive control, highlighting a general effect of training on cognitive flexibility. The present results reveal specific and general modulations of executive control mechanisms after brief training intervention targeting either WM or IC. PMID:27917117
A survey of infection control teaching in U.S. dental schools.
Porteous, Nuala B; Bizra, Eamon; Cothron, Annaliese; Yeh, Chih-Ko
2014-02-01
This study was conducted to determine the content of infection control (IC) curricula, the extent of IC monitoring and compliance, and the number of bloodborne pathogen (BBP) exposures/year in U.S. dental schools. A questionnaire was emailed to persons responsible for predoctoral IC programs. The response rate was 60 percent. Most schools did not have an independent course and used classroom lectures and clinic demonstrations to teach IC. Schools with an IC committee were more likely to use online learning (p<0.05), utilize multiple teaching methods (p<0.05), issue written warnings for IC violations (p<0.0001), and use multiple disciplinary actions (p<0.005) than schools without an IC committee. Schools with an IC coordinator were less likely to issue grade reductions for IC violations than schools with no IC coordinator (p<0.05). Thirty-eight percent reported ≥ 16 BBP exposures/year, and 18 percent reported <5. There was significant correlation between BBP exposure incidents and large class size (p<0.005). Respondents were satisfied with their IC curriculum and perceived that dental students had a high level of IC compliance and satisfaction, along with staff IC promotion and compliance. The findings suggest that schools without an IC committee should consider its benefits. Further investigation of schools with high numbers of BBP exposures is recommended.
Inhaled corticosteroids and asthma control in adult-onset asthma: 12-year follow-up study.
Vähätalo, Iida; Ilmarinen, Pinja; Tuomisto, Leena E; Niemelä, Onni; Kankaanranta, Hannu
2018-04-01
Prescribed inhaled corticosteroid (ICS) doses in asthma have been studied in cross-sectional settings whereas long-term follow-up studies have not been carried out. To evaluate prescribed medication longitudinally by calculating cumulative ICS doses and dose changes in a cohort of new-onset adult asthma during 12 years and in different groups of asthma control. A total of 203 patients were followed for 12 years as part of Seinäjoki Adult Asthma Study (SAAS). All asthma-related visits and prescribed medication over the study period were collected from medical records. Total cumulative ICS dose for the 12-year follow-up period was 3.4g (±SEM 0.1) per patient. Both respiratory specialists and GPs prescribed step-ups and step-downs in ICS treatment and in total 649 dose changes were noted during the follow-up (median 3(1-5) per patient). Patients with uncontrolled asthma received higher ICS doses throughout the follow-up period, and therefore, cumulative 12-year ICS dose (3.8g ± SEM 0.2) in this group was higher than that in those with partially controlled (3.4g ± SEM 0.2) or controlled disease (2.9g ± SEM 0.2) (p = 0.0001). Patients with uncontrolled asthma were also prescribed a higher number of ICS dose changes than patients with controlled disease. Despite frequent dose changes and high ICS doses during the 12-year follow-up, the level of asthma control remained poor in patients with uncontrolled asthma. This suggests that high ICS doses may not be effective enough for management of disease in patients with uncontrolled adult-onset asthma and novel targeted treatments are required. Copyright © 2018 Elsevier Ltd. All rights reserved.
The instrument control software package for the Habitable-Zone Planet Finder spectrometer
NASA Astrophysics Data System (ADS)
Bender, Chad F.; Robertson, Paul; Stefansson, Gudmundur Kari; Monson, Andrew; Anderson, Tyler; Halverson, Samuel; Hearty, Frederick; Levi, Eric; Mahadevan, Suvrath; Nelson, Matthew; Ramsey, Larry; Roy, Arpita; Schwab, Christian; Shetrone, Matthew; Terrien, Ryan
2016-08-01
We describe the Instrument Control Software (ICS) package that we have built for The Habitable-Zone Planet Finder (HPF) spectrometer. The ICS controls and monitors instrument subsystems, facilitates communication with the Hobby-Eberly Telescope facility, and provides user interfaces for observers and telescope operators. The backend is built around the asynchronous network software stack provided by the Python Twisted engine, and is linked to a suite of custom hardware communication protocols. This backend is accessed through Python-based command-line and PyQt graphical frontends. In this paper we describe several of the customized subsystem communication protocols that provide access to and help maintain the hardware systems that comprise HPF, and show how asynchronous communication benefits the numerous hardware components. We also discuss our Detector Control Subsystem, built as a set of custom Python wrappers around a C-library that provides native Linux access to the SIDECAR ASIC and Hawaii-2RG detector system used by HPF. HPF will be one of the first astronomical instruments on sky to utilize this native Linux capability through the SIDECAR Acquisition Module (SAM) electronics. The ICS we have created is very flexible, and we are adapting it for NEID, NASA's Extreme Precision Doppler Spectrometer for the WIYN telescope; we will describe this adaptation, and describe the potential for use in other astronomical instruments.
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, A.N.; Soden, J.M.
1998-12-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits are disclosed. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal. 4 figs.
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, Ann N.; Soden, Jerry M.
1998-01-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal.
Rangé, G; Chassaing, S; Marcollet, P; Saint-Étienne, C; Dequenne, P; Goralski, M; Bardiére, P; Beverilli, F; Godillon, L; Sabine, B; Laure, C; Gautier, S; Hakim, R; Albert, F; Angoulvant, D; Grammatico-Guillon, L
2018-05-01
To assess the reliability and low cost of a computerized interventional cardiology (IC) registry to prospectively and systematically collect high-quality data for all consecutive coronary patients referred for coronary angiogram or/and coronary angioplasty. Rigorous clinical practice assessment is a key factor to improve prognosis in IC. A prospective and permanent registry could achieve this goal but, presumably, at high cost and low level of data quality. One multicentric IC registry (CRAC registry), fully integrated to usual coronary activity report software, started in the centre Val-de-Loire (CVL) French region in 2014. Quality assessment of CRAC registry was conducted on five IC CathLab of the CVL region, from January 1st to December 31st 2014. Quality of collected data was evaluated by measuring procedure exhaustivity (comparing with data from hospital information system), data completeness (quality controls) and data consistency (by checking complete medical charts as gold standard). Cost per procedure (global registry operating cost/number of collected procedures) was also estimated. CRAC model provided a high-quality level with 98.2% procedure completeness, 99.6% data completeness and 89% data consistency. The operating cost per procedure was €14.70 ($16.51) for data collection and quality control, including ST-segment elevation myocardial infarction (STEMI) preadmission information and one-year follow-up after angioplasty. This integrated computerized IC registry led to the construction of an exhaustive, reliable and costless database, including all coronary patients entering in participating IC centers in the CVL region. This solution will be developed in other French regions, setting up a national IC database for coronary patients in 2020: France PCI. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
The inherent weaknesses in industrial control systems devices; hacking and defending SCADA systems
NASA Astrophysics Data System (ADS)
Bianco, Louis J.
The North American Electric Reliability Corporation (NERC) is about to enforce their NERC Critical Infrastructure Protection (CIP) Version Five and Six requirements on July 1st 2016. The NERC CIP requirements are a set of cyber security standards designed to protect cyber assets essential the reliable operation of the electric grid. The new Version Five and Six requirements are a major revision to the Version Three (currently enforced) requirements. The new requirements also bring substations into scope alongside Energy Control Centers. When the Version Five requirements were originally drafted they were vague, causing in depth discussions throughout the industry. The ramifications of these requirements has made owners look at their systems in depth, questioning how much money it will take to meet these requirements. Some owners saw backing down from routable networks to non-routable as a means to save money as they would be held to less requirements within the standards. Some owners saw removing routable connections as a proper security move. The purpose of this research was to uncover the inherent weaknesses in Industrial Control Systems (ICS) devices; to show how ICS devices can be hacked and figure out potential protections for these Critical Infrastructure devices. In addition, this research also aimed to validate the decision to move from External Routable connectivity to Non-Routable connectivity, as a security measure and not as a means of savings. The results reveal in order to ultimately protect Industrial Control Systems they must be removed from the Internet and all bi-directional external routable connections must be removed. Furthermore; non-routable serial connections should be utilized, and these non-routable serial connections should be encrypted on different layers of the OSI model. The research concluded that most weaknesses in SCADA systems are due to the inherent weaknesses in ICS devices and because of these weaknesses, human intervention is the biggest threat to SCADA systems.
Techniques for the inorganic analysis in a controlled ecological life support system
NASA Technical Reports Server (NTRS)
1983-01-01
Sample preparation, instrumental analysis, a direct injection device for IC/ICP interfacing, a hydraulic jet bend impaction device, monodisperse aerosol generator, and low gravity environments are discussed.
Lidar In-space Technology Experiment (LITE) Electronics Overview
NASA Technical Reports Server (NTRS)
Blythe, Michael P.; Couch, Richard H.; Rowland, Carroll W.; Kitchen, Wayne L.; Regan, Curtis P.; Koch, Michael R.; Antill, Charles W.; Stevens, William T.; Rollins, Courtney H.; Kist, Edward H.
1992-01-01
The LITE electronics system consists of the following seven subsystems: Laser Transmitter Module (LTM), Boresight Assembly (BA), Aft-Optics Electronics (AOE), Digital Data Handling Unit (DDHU), Engineering Data System (EDS), Instrument Controller (IC), and the Ground Support Equipment (GSE). Each of these subsystems is discussed.
Light-induced voltage alteration for integrated circuit analysis
Cole, Jr., Edward I.; Soden, Jerry M.
1995-01-01
An apparatus and method are described for analyzing an integrated circuit (IC), The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC, The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs.
Light-induced voltage alteration for integrated circuit analysis
Cole, E.I. Jr.; Soden, J.M.
1995-07-04
An apparatus and method are described for analyzing an integrated circuit (IC). The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC. The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs. 18 figs.
Chen, Chang Hao; McCullagh, Elizabeth A; Pun, Sio Hang; Mak, Peng Un; Vai, Mang I; Mak, Pui In; Klug, Achim; Lei, Tim C
2017-03-01
The ability to record and to control action potential firing in neuronal circuits is critical to understand how the brain functions. The objective of this study is to develop a monolithic integrated circuit (IC) to record action potentials and simultaneously control action potential firing using optogenetics. A low-noise and high input impedance (or low input capacitance) neural recording amplifier is combined with a high current laser/light-emitting diode (LED) driver in a single IC. The low input capacitance of the amplifier (9.7 pF) was achieved by adding a dedicated unity gain stage optimized for high impedance metal electrodes. The input referred noise of the amplifier is [Formula: see text], which is lower than the estimated thermal noise of the metal electrode. Thus, the action potentials originating from a single neuron can be recorded with a signal-to-noise ratio of at least 6.6. The LED/laser current driver delivers a maximum current of 330 mA, which is adequate for optogenetic control. The functionality of the IC was tested with an anesthetized Mongolian gerbil and auditory stimulated action potentials were recorded from the inferior colliculus. Spontaneous firings of fifth (trigeminal) nerve fibers were also inhibited using the optogenetic protein Halorhodopsin. Moreover, a noise model of the system was derived to guide the design. A single IC to measure and control action potentials using optogenetic proteins is realized so that more complicated behavioral neuroscience research and the translational neural disorder treatments become possible in the future.
De Martino, Federico; Gentile, Francesco; Esposito, Fabrizio; Balsi, Marco; Di Salle, Francesco; Goebel, Rainer; Formisano, Elia
2007-01-01
We present a general method for the classification of independent components (ICs) extracted from functional MRI (fMRI) data sets. The method consists of two steps. In the first step, each fMRI-IC is associated with an IC-fingerprint, i.e., a representation of the component in a multidimensional space of parameters. These parameters are post hoc estimates of global properties of the ICs and are largely independent of a specific experimental design and stimulus timing. In the second step a machine learning algorithm automatically separates the IC-fingerprints into six general classes after preliminary training performed on a small subset of expert-labeled components. We illustrate this approach in a multisubject fMRI study employing visual structure-from-motion stimuli encoding faces and control random shapes. We show that: (1) IC-fingerprints are a valuable tool for the inspection, characterization and selection of fMRI-ICs and (2) automatic classifications of fMRI-ICs in new subjects present a high correspondence with those obtained by expert visual inspection of the components. Importantly, our classification procedure highlights several neurophysiologically interesting processes. The most intriguing of which is reflected, with high intra- and inter-subject reproducibility, in one IC exhibiting a transiently task-related activation in the 'face' region of the primary sensorimotor cortex. This suggests that in addition to or as part of the mirror system, somatotopic regions of the sensorimotor cortex are involved in disambiguating the perception of a moving body part. Finally, we show that the same classification algorithm can be successfully applied, without re-training, to fMRI collected using acquisition parameters, stimulation modality and timing considerably different from those used for training.
[Risk factors found in suicide attempters].
Villa-Manzano, Alberto Iram; Robles-Romero, Miguel Angel; Gutiérrez-Román, Elsa Armida; Martínez-Arriaga, María Guadalupe; Valadez-Toscano, Francisco Javier; Cabrera-Pivaral, Carlos E
2009-01-01
A better understanding of risk factors for suicide in general population is crucial for the design of suicide prevention programs. Our objective was to identify personal and family risk factors in suicide attempters. Case-control design. We searched in patients with an acute intoxication, those subjects with and intoxication attributable to suicide attempt. These patients were matched with controls by gender and the date of intoxication. We use a structured questionnaire to identify personal characteristics, family features and network support. Odds ratio (OR) and 95 % confidence interval were obtained. 25 cases and 25 controls were evaluated. The risk factors associated with suicide attempt adjusted by age, were being a student and smoking habits. Family violence background showed OR = 3.8 (IC 95 % = 1.1-13), family disintegration a OR = 8.5 (IC 95 % = 2.1-35), critical events background OR = 8.8 (IC 95 % = 2.1-36), poor self-esteem OR = 8.2 (IC 95 % 2-35), depression OR = 22 (IC 95 % = 3-190), anxiety OR = 9 (IC 95 % = 2-47), family dysfunction OR = 25 (IC 95 % = 4-151). The principal risk factor for suicide attempt was family dysfunction and psychological traits.
Identification of Modeling Approaches To Support Common-Cause Failure Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, Kofi; Wood, Richard Thomas
2015-06-01
Experience with applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The impact of CCF vulnerability is to inhibit I&C modernization and, thereby, challenge the long-term sustainability of existing plants. For new plants and advanced reactor concepts, the issue of CCF vulnerability for highly integrated digital I&C systems imposes a design burden resulting in higher costs and increased complexity. The regulatory uncertainty regarding which mitigation strategies are acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adoptmore » complicated, costly solutions devised for existing plants. The conditions that constrain the transition to digital I&C technology by the U.S. nuclear industry require crosscutting research to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for usage in Nuclear Power Plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is conducting an investigation into mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive technical basis for establishing the qualification of digital technology for nuclear power applications. This report documents the investigation of modeling approaches for representing failure of I&C systems. Failure models are used when there is a need to analyze how the probability of success (or failure) of a system depends on the success (or failure) of individual elements. If these failure models are extensible to represent CCF, then they can be employed to support analysis of CCF vulnerabilities and mitigation strategies. Specifically, the research findings documented in this report identify modeling approaches that can be adapted to contribute to the basis for developing systematic methods, quantifiable measures, and objective criteria for evaluating CCF vulnerabilities and mitigation strategies.« less
Taxonomy for Common-Cause Failure Vulnerability and Mitigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Richard Thomas; Korsah, Kofi; Mullens, James Allen
2015-09-01
Applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The potential for CCF vulnerability inhibits I&C modernization, thereby challenging the long-term sustainability of existing plants. For new plants and advanced reactor concepts, concern about CCF vulnerability in highly integrated digital I&C systems imposes a design burden that results in higher costs and increased complexity. The regulatory uncertainty in determining which mitigation strategies will be acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adopt complicated, costly solutionsmore » devised for existing plants. To address the conditions that constrain the transition to digital I&C technology by the US nuclear industry, crosscutting research is needed to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for nuclear power plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is investigating mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive basis to qualify digital technology for nuclear power applications. This report documents the development of a CCF taxonomy. The basis for the CCF taxonomy was generated by determining consistent terminology and establishing a classification approach. The terminology is based on definitions from standards, guides, and relevant nuclear power industry technical reports. The classification approach is derived from identified classification schemes focused on I&C systems and key characteristics, including failure modes. The CCF taxonomy provides the basis for a systematic organization of key systems aspects relevant to analyzing the potential for CCF vulnerability and the suitability of mitigation techniques. Development of an effective CCF taxonomy will help to provide a framework for establishing the objective analysis and assessment capabilities desired to facilitate rigorous identification of fault types and triggers that are the fundamental elements of CCF.« less
Bus current analysis of high power cryocooler's controller
NASA Astrophysics Data System (ADS)
Jin, Zhanlei; Sun, Qiyang; Dai, Liqun; Dong, Jie
2016-03-01
Current analysis was an important research content for reducing power of cryocooler's controller. Simulation was done among load current, H bridge current and power current refer to 42V bus power voltage. Then relationship among IL1, IC1, ρ and IM1 was established. Simulation results indicate that IL1-max, IL1-ave, IL1-rms, IC1-min and IC1-ave were linearly increasing to ρ and IM1, especially IL1-rms ≈ 0.612ρ IM1-max . IC1-rms increase firstly then decrease with the increasing of ρ. IC1-rms reaches maximum when ρ=0.8, then ICL-rms =(12.32/RM1 + 0.98) exp -((ρ-0.78)/0.57)2. The results were useful for miniaturizing cryocooler's controller.
Shulman, Nick; Bellew, Matthew; Snelling, George; Carter, Donald; Huang, Yunda; Li, Hongli; Self, Steven G.; McElrath, M. Juliana; De Rosa, Stephen C.
2008-01-01
Background Intracellular cytokine staining (ICS) by multiparameter flow cytometry is one of the primary methods for determining T cell immunogenicity in HIV-1 clinical vaccine trials. Data analysis requires considerable expertise and time. The amount of data is quickly increasing as more and larger trials are performed, and thus there is a critical need for high throughput methods of data analysis. Methods A web based flow cytometric analysis system, LabKey Flow, was developed for analyses of data from standardized ICS assays. A gating template was created manually in commercially-available flow cytometric analysis software. Using this template, the system automatically compensated and analyzed all data sets. Quality control queries were designed to identify potentially incorrect sample collections. Results Comparison of the semi-automated analysis performed by LabKey Flow and the manual analysis performed using FlowJo software demonstrated excellent concordance (concordance correlation coefficient >0.990). Manual inspection of the analyses performed by LabKey Flow for 8-color ICS data files from several clinical vaccine trials indicates that template gates can appropriately be used for most data sets. Conclusions The semi-automated LabKey Flow analysis system can analyze accurately large ICS data files. Routine use of the system does not require specialized expertise. This high-throughput analysis will provide great utility for rapid evaluation of complex multiparameter flow cytometric measurements collected from large clinical trials. PMID:18615598
1995-11-01
jurisdiction of the Department of the Interior’s Bureau of Land Management (BLM). Flue - Gas Desulfurization (FGD). Post-combustion sulfur dioxide control ...National Pollution Discharge Elimination System Permits .......... 11 VIII Individual Control Strategies for Toxic Pollutants (ICS) ........... 14 IX Storm...individual control strategies be integrated into the sources’ NPDES permits. EPA has established water quality standards for a number of toxic
NASA Technical Reports Server (NTRS)
Carden, J. L.; Browner, R.
1982-01-01
The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.
Circulating immune complexes contain citrullinated fibrinogen in rheumatoid arthritis
Zhao, Xiaoyan; Okeke, Nwora Lance; Sharpe, Orr; Batliwalla, Franak M; Lee, Annette T; Ho, Peggy P; Tomooka, Beren H; Gregersen, Peter K; Robinson, William H
2008-01-01
Introduction There is increasing evidence that autoantibodies and immune complexes (ICs) contribute to synovitis in rheumatoid arthritis (RA), yet the autoantigens incorporated in ICs in RA remain incompletely characterised. Methods We used the C1q protein to capture ICs from plasma derived from human RA and control patients. Antibodies specific for immunoglobulin were used to detect ICs, and fibrinogen antibodies were used to detect fibrinogen-containing ICs. RA and control plasma were separated by liquid chromatography, and fractions then characterised by ELISA, immunoblotting and mass spectrometry. Immunohistochemical staining was performed on rheumatoid synovial tissue. Results C1q-immunoassays demonstrated increased levels of IgG (p = 0.01) and IgM (p = 0.0002) ICs in plasma derived from RA patients possessing anti-cyclic citrullinated peptide (CCP+) autoantibodies as compared with healthy controls. About one-half of the anti-CCP+ RA possessed circulating ICs containing fibrinogen (p = 0.0004). Fractionation of whole RA plasma revealed citrullinated fibrinogen in the high molecular weight fractions that contained ICs. Positive correlations were observed between fibrinogen-containing ICs and anti-citrullinated fibrinogen autoantibodies, anti-CCP antibody, rheumatoid factor and certain clinical characteristics. Immunohistochemical staining demonstrated co-localisation of fibrinogen, immunoglobulin and complement component C3 in RA pannus tissue. Mass spectrometry analysis of immune complexes immunoprecipitated from RA pannus tissue lysates demonstrated the presence of citrullinated fibrinogen. Conclusion Circulating ICs containing citrullinated fibrinogen are present in one-half of anti-CCP+ RA patients, and these ICs co-localise with C3 in the rheumatoid synovium suggesting that they contribute to synovitis in a subset of RA patients. PMID:18710572
Vasbinder, Erwin C; Janssens, Hettie M; Rutten-van Mölken, Maureen P M H; van Dijk, Liset; de Winter, Brenda C M; de Groot, Ruben C A; Vulto, Arnold G; van den Bemt, Patricia M L A
2013-03-21
Many children with asthma do not have sufficient asthma control, which leads to increased healthcare costs and productivity loss of parents. One of the causative factors are adherence problems. Effective interventions improving medication adherence may therefore improve asthma control and reduce costs. A promising solution is sending real time text-messages via the mobile phone network, when a medicine is about to be forgotten. As the effect of real time text-messages in children with asthma is unknown, the primary aim of this study is to determine the effect of a Real Time Medication Monitoring system (RTMM) with text-messages on adherence to inhaled corticosteroids (ICS). The secondary objective is to study the effects of RTMM on asthma control, quality of life and cost-effectiveness of treatment. A multicenter, randomized controlled trial involving 220 children (4-11 years) using ICS for asthma. All children receive an RTMM-device for one year, which registers time and date of ICS doses. Children in the intervention group also receive tailored text-messages, sent only when a dose is at risk of omission. Primary outcome measure is the proportion of ICS dosages taken within the individually predefined time-interval. Secondary outcome measures include asthma control (monthly Asthma Control Tests), asthma exacerbations, healthcare use (collected from hospital records, patient reports and pharmacy record data), and disease-specific quality of life (PAQLQ questionnaire). Parental and children's acceptance of RTMM is evaluated with online focus groups and patient questionnaires. An economic evaluation is performed adopting a societal perspective, including relevant healthcare costs and parental productivity loss. Furthermore, a decision-analytic model is developed in which different levels of adherence are associated with clinical and financial outcomes. Also, sensitivity analyses are carried out on different price levels for RTMM. If RTMM with tailored text-message reminders proves to be effective, this technique can be used in daily practice, which would support children with suboptimal adherence in their asthma (self)management and in achieving better asthma control and better quality of life. Netherlands Trial Register NTR2583.
Post-Inhaled Corticosteroid Pulmonary Tuberculosis Increases Lung Cancer in Patients with Asthma.
Jian, Zhi-Hong; Huang, Jing-Yang; Lin, Frank Cheau-Feng; Nfor, Oswald Ndi; Jhang, Kai-Ming; Ku, Wen-Yuan; Ho, Chien-Chang; Lung, Chia-Chi; Pan, Hui-Hsien; Wu, Min-Chen; Wu, Ming-Fang; Liaw, Yung-Po
2016-01-01
To evaluate the association between post-inhaled corticosteroid (ICS) pulmonary tuberculosis (TB), pneumonia and lung cancer in patients with asthma. The study samples were collected from the National Health Insurance Database. Asthmatic patients who were first-time users of ICS between 2003 and 2005 were identified as cases. For each case, 4 control individuals were randomly matched for sex, age and date of ICS use. Cases and matched controls were followed up until the end of 2010. Cox proportional hazard regression was used to determine the hazard ratio for pulmonary infections and lung cancer risk in the ICS users and non-users. A total of 10,904 first-time users of ICS were matched with 43,616 controls. The hazard ratios for lung cancer were: 2.52 (95% confidence interval [CI], 1.22-5.22; p = 0.012) for individuals with post-ICS TB, 1.28 (95%CI, 0.73-2.26; p = 0.389) for post-ICS pneumonia, 2.31(95%CI, 0.84-6.38; p = 0.105) for post-ICS pneumonia+TB, 1.08 (95%CI, 0.57-2.03; p = 0.815) for TB, 0.99 (95%CI, 0.63-1.55; p = 0.970) for pneumonia, and 0.32 (95%CI, 0.05-2.32; p = 0.261) for pneumonia+ TB, respectively. Post-ICS TB increased lung cancer risk in patients with asthma. Because of the high mortality associated with lung cancer, screening tests are recommended for patients with post-ICS TB.
Joore, Ivo K; Twisk, Denise E; Vanrolleghem, Ann M; de Ridder, Maria; Geerlings, Suzanne E; van Bergen, Jan E A M; van den Broek, Ingrid V
2016-11-17
European guidelines recommend offering an HIV test to individuals who display HIV indicator conditions (ICs). We aimed to investigate the incidence of ICs in primary care reported in medical records prior to HIV diagnosis. We did a cross-sectional search in an electronic general practice database using a matched case-control design to identify which predefined ICs registered by Dutch GPs were most associated with an HIV-positive status prior to the time of diagnosis. We included 224 HIV cases diagnosed from 2009 to 2013, which were matched with 2,193 controls. Almost two thirds (n = 136, 60.7%) of cases were diagnosed with one or more ICs in the period up to five years prior to the index date compared to 18.7% (n = 411) of controls. Cases were more likely to have an IC than controls: in the one year prior to the index date, the odds ratio (OR) for at least one condition was 11.7 (95% CI: 8.3 to 16.4). No significant differences were seen in the strength of the association between HIV diagnosis and ICs when comparing genders, age groups or urbanisation levels. There is no indication that subgroups require a different testing strategy. Our study shows that there are opportunities for IC-guided testing in primary care. We recommend that IC-guided testing be more integrated in GPs' future guidelines and that education strategies be used to facilitate its implementation in daily practice.
Incident Specific Preparedness Review (ISPR) of the Response to the Houston Oil Spill
DOT National Transportation Integrated Search
1996-07-30
The focus areas used for this ISPR were: Area Contingency Plan; : Command, Control, Communications/Incident Command System (C3/ICS); Interagency Coordination and Public Affairs; Logistics; Finance; and Miscellaneous.
Variational data assimilation system "INM RAS - Black Sea"
NASA Astrophysics Data System (ADS)
Parmuzin, Eugene; Agoshkov, Valery; Assovskiy, Maksim; Giniatulin, Sergey; Zakharova, Natalia; Kuimov, Grigory; Fomin, Vladimir
2013-04-01
Development of Informational-Computational Systems (ICS) for Data Assimilation Procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in: mathematical modeling; theory of adjoint equations and optimal control; inverse problems; numerical methods theory; numerical algebra and scientific computing. The problems discussed above are studied in the Institute of Numerical Mathematics of the Russian Academy of Science (INM RAS) in ICS for Personal Computers (PC). Special problems and questions arise while effective ICS versions for PC are being developed. These problems and questions can be solved with applying modern methods of numerical mathematics and by solving "parallelism problem" using OpenMP technology and special linear algebra packages. In this work the results on the ICS development for PC-ICS "INM RAS - Black Sea" are presented. In the work the following problems and questions are discussed: practical problems that can be studied by ICS; parallelism problems and their solutions with applying of OpenMP technology and the linear algebra packages used in ICS "INM - Black Sea"; Interface of ICS. The results of ICS "INM RAS - Black Sea" testing are presented. Efficiency of technologies and methods applied are discussed. The work was supported by RFBR, grants No. 13-01-00753, 13-05-00715 and by The Ministry of education and science of Russian Federation, project 8291, project 11.519.11.1005 References: [1] V.I. Agoshkov, M.V. Assovskii, S.A. Lebedev, Numerical simulation of Black Sea hydrothermodynamics taking into account tide-forming forces. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 5-31 [2] E.I. Parmuzin, V.I. Agoshkov, Numerical solution of the variational assimilation problem for sea surface temperature in the model of the Black Sea dynamics. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 69-94 [3] V.B. Zalesny, N.A. Diansky, V.V. Fomin, S.N. Moshonkin, S.G. Demyshev, Numerical model of the circulation of Black Sea and Sea of Azov. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 95-111 [4] V.I. Agoshkov, S.V. Giniatulin, G.V. Kuimov. OpenMP technology and linear algebra packages in the variation data assimilation systems. - Abstracts of the 1-st China-Russia Conference on Numerical Algebra with Applications in Radiactive Hydrodynamics, Beijing, China, October 16-18, 2012. [5] Zakharova N.B., Agoshkov V.I., Parmuzin E.I., The new method of ARGO buoys system observation data interpolation. Russian Journal of Numerical Analysis and Mathematical Modelling. Vol. 28, Issue 1, 2013.
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, Jens; Störmer, Melanie; Kleesiek, Knut
2005-01-01
Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 replicase gene, which differ in detection format, amplicon size, and efficiency of amplification. These noncompetitive IC assays, using TaqMan, hybridization probe, or duplex scorpion probe techniques, were tested on the LightCycler and Rotorgene systems. In our approach, clinical specimens were spiked with the control virus to monitor the efficiency of extraction, reverse transcription, and amplification steps. The MS2 RT-PCR assays were applied for internal control when using a second target hepatitis C virus RNA in duplex PCR in blood donor screening. The 95% detection limit was calculated by probit analysis to 44.9 copies per PCR (range, 38.4 to 73.4). As demonstrated routinely, application of MS2 IC assays exhibits low variability and can be applied in various RT-PCR assays. MS2 phage lysates were obtained under standard laboratory conditions. The quantification of phage and template RNA was performed by plating assays to determine PFU or via real-time RT-PCR. High stability of the MS2 phage preparations stored at −20°C, 4°C, and room temperature was demonstrated. PMID:16145106
Use of internal control T-cell populations in the flow cytometric evaluation for T-cell neoplasms.
Hunt, Alicia M; Shallenberger, Wendy; Ten Eyck, Stephen P; Craig, Fiona E
2016-09-01
Flow cytometry is an important tool for identification of neoplastic T-cells, but immunophenotypic abnormalities are often subtle and must be distinguished from nonneoplastic subsets. Use of internal control (IC) T-cells in the evaluation for T-cell neoplasms was explored, both as a quality measure and as a reference for evaluating abnormal antigen expression. All peripheral blood specimens (3-month period), or those containing abnormal T-cells (29-month period), stained with CD45 V500, CD2 V450, CD3 PE-Cy7, CD7 PE, CD4 Per-CP-Cy5.5, CD8 APC-H7, CD56 APC, CD16&57 FITC, were evaluated. IC T-cells were identified (DIVA, BD Biosciences) and median fluorescence intensity (MFI) recorded. Selected files were merged and reference templates generated (Infinicyt, Cytognos). IC T-cells were present in all specimens, including those with abnormal T-cells, but subsets were less well-represented. IC T-cell CD3 MFI differed between instruments (p = 0.0007) and subsets (p < 0.001), but not specimen categories, and served as a longitudinal process control. Merged files highlighted small unusual IC-T subsets: CD2+(dim) (0.25% total), CD2- (0.03% total). An IC reference template highlighted neoplastic T-cells, but was limited by staining variability (IC CD3 MFI reference samples different from test (p = 0.003)). IC T-cells present in the majority of specimens can serve as positive and longitudinal process controls. Use of IC T-cells as an internal reference is limited by variable representation of subsets. Analysis of merged IC T-cells from previously analyzed patient samples can alert the interpreter to less-well-recognized non-neoplastic subsets. However, application of a merged file IC reference template was limited by staining variability. © 2016 Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gökçe, M., E-mail: mgokce@adu.edu.tr; Uslu, D. Koçyiğit; Ertunç, C.
The aim of this study is to compare Intensity Modulated Radiation Therapy (IMRT) plan of prostate cancer patients with different dose verification systems in dosimetric aspects and to compare these systems with each other in terms of reliability, applicability and application time. Dosimetric control processes of IMRT plan of three prostate cancer patients were carried out using thermoluminescent dosimeter (TLD), ion chamber (IC) and 2D Array detector systems. The difference between the dose values obtained from the dosimetric systems and treatment planning system (TPS) were found to be about % 5. For the measured (TLD) and calculated (TPS) doses %3more » percentage differences were obtained for the points close to center while percentage differences increased at the field edges. It was found that TLD and IC measurements will increase the precision and reliability of the results of 2D Array.« less
Zambenedetti, Miriam Ribas; Pavoni, Daniela Parada; Dallabona, Andreia Cristine; Dominguez, Alejandro Correa; Poersch, Celina de Oliveira; Fragoso, Stenio Perdigão; Krieger, Marco Aurélio
2017-05-01
Real-time reverse transcription polymerase chain reaction (RT-PCR) is routinely used to detect viral infections. In Brazil, it is mandatory the use of nucleic acid tests to detect hepatitis C virus (HCV), hepatitis B virus and human immunodeficiency virus in blood banks because of the immunological window. The use of an internal control (IC) is necessary to differentiate the true negative results from those consequent from a failure in some step of the nucleic acid test. The aim of this study was the construction of virus-modified particles, based on MS2 bacteriophage, to be used as IC for the diagnosis of RNA viruses. The MS2 genome was cloned into the pET47b(+) plasmid, generating pET47b(+)-MS2. MS2-like particles were produced through the synthesis of MS2 RNA genome by T7 RNA polymerase. These particles were used as non-competitive IC in assays for RNA virus diagnostics. In addition, a competitive control for HCV diagnosis was developed by cloning a mutated HCV sequence into the MS2 replicase gene of pET47b(+)-MS2, which produces a non-propagating MS2 particle. The utility of MS2-like particles as IC was evaluated in a one-step format multiplex real-time RT-PCR for HCV detection. We demonstrated that both competitive and non-competitive IC could be successfully used to monitor the HCV amplification performance, including the extraction, reverse transcription, amplification and detection steps, without compromising the detection of samples with low target concentrations. In conclusion, MS2-like particles generated by this strategy proved to be useful IC for RNA virus diagnosis, with advantage that they are produced by a low cost protocol. An attractive feature of this system is that it allows the construction of a multicontrol by the insertion of sequences from more than one pathogen, increasing its applicability for diagnosing different RNA viruses.
Zambenedetti, Miriam Ribas; Pavoni, Daniela Parada; Dallabona, Andreia Cristine; Dominguez, Alejandro Correa; Poersch, Celina de Oliveira; Fragoso, Stenio Perdigão; Krieger, Marco Aurélio
2017-01-01
BACKGROUND Real-time reverse transcription polymerase chain reaction (RT-PCR) is routinely used to detect viral infections. In Brazil, it is mandatory the use of nucleic acid tests to detect hepatitis C virus (HCV), hepatitis B virus and human immunodeficiency virus in blood banks because of the immunological window. The use of an internal control (IC) is necessary to differentiate the true negative results from those consequent from a failure in some step of the nucleic acid test. OBJECTIVES The aim of this study was the construction of virus-modified particles, based on MS2 bacteriophage, to be used as IC for the diagnosis of RNA viruses. METHODS The MS2 genome was cloned into the pET47b(+) plasmid, generating pET47b(+)-MS2. MS2-like particles were produced through the synthesis of MS2 RNA genome by T7 RNA polymerase. These particles were used as non-competitive IC in assays for RNA virus diagnostics. In addition, a competitive control for HCV diagnosis was developed by cloning a mutated HCV sequence into the MS2 replicase gene of pET47b(+)-MS2, which produces a non-propagating MS2 particle. The utility of MS2-like particles as IC was evaluated in a one-step format multiplex real-time RT-PCR for HCV detection. FINDINGS We demonstrated that both competitive and non-competitive IC could be successfully used to monitor the HCV amplification performance, including the extraction, reverse transcription, amplification and detection steps, without compromising the detection of samples with low target concentrations. In conclusion, MS2-like particles generated by this strategy proved to be useful IC for RNA virus diagnosis, with advantage that they are produced by a low cost protocol. An attractive feature of this system is that it allows the construction of a multicontrol by the insertion of sequences from more than one pathogen, increasing its applicability for diagnosing different RNA viruses. PMID:28403327
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anheier, Norman C.; Suter, Jonathan D.; Qiao, Hong
2013-08-06
This report intends to support Department of Energy’s Office of Nuclear Energy (DOE-NE) Nuclear Energy Research and Development Roadmap and industry stakeholders by evaluating optical-based instrumentation and control (I&C) concepts for advanced small modular reactor (AdvSMR) applications. These advanced designs will require innovative thinking in terms of engineering approaches, materials integration, and I&C concepts to realize their eventual viability and deployability. The primary goals of this report include: 1. Establish preliminary I&C needs, performance requirements, and possible gaps for AdvSMR designs based on best available published design data. 2. Document commercial off-the-shelf (COTS) optical sensors, components, and materials in termsmore » of their technical readiness to support essential AdvSMR in-vessel I&C systems. 3. Identify technology gaps by comparing the in-vessel monitoring requirements and environmental constraints to COTS optical sensor and materials performance specifications. 4. Outline a future research, development, and demonstration (RD&D) program plan that addresses these gaps and develops optical-based I&C systems that enhance the viability of future AdvSMR designs. The development of clean, affordable, safe, and proliferation-resistant nuclear power is a key goal that is documented in the Nuclear Energy Research and Development Roadmap. This roadmap outlines RD&D activities intended to overcome technical, economic, and other barriers, which currently limit advances in nuclear energy. These activities will ensure that nuclear energy remains a viable component to this nation’s energy security.« less
Inhibitory control and the speech patterns of second language users.
Korko, Malgorzata; Williams, Simon A
2017-02-01
Inhibitory control (IC), an ability to suppress irrelevant and/or conflicting information, has been found to underlie performance on a variety of cognitive tasks, including bilingual language processing. This study examines the relationship between IC and the speech patterns of second language (L2) users from the perspective of individual differences. While the majority of studies have supported the role of IC in bilingual language processing using single-word production paradigms, this work looks at inhibitory processes in the context of extended speech, with a particular emphasis on disfluencies. We hypothesized that the speech of individuals with poorer IC would be characterized by reduced fluency. A series of regression analyses, in which we controlled for age and L2 proficiency, revealed that IC (in terms of accuracy on the Stroop task) could reliably predict the occurrence of reformulations and the frequency and duration of silent pauses in L2 speech. No statistically significant relationship was found between IC and other L2 spoken output measures, such as repetitions, filled pauses, and performance errors. Conclusions focus on IC as one out of a number of cognitive functions in the service of spoken language production. A more qualitative approach towards the question of whether L2 speakers rely on IC is advocated. © 2016 The British Psychological Society.
A proposed holistic approach to on-chip, off-chip, test, and package interconnections
NASA Astrophysics Data System (ADS)
Bartelink, Dirk J.
1998-11-01
The term interconnection has traditionally implied a `robust' connection from a transistor or a group of transistors in an IC to the outside world, usually a PC board. Optimum system utilization is done from outside the IC. As an alternative, this paper addresses `unimpeded' transistor-to-transistor interconnection aimed at reaching the high circuit densities and computational capabilities of neighboring IC's. In this view, interconnections are not made to some human-centric place outside the IC world requiring robustness—except for system input and output connections. This unimpeded interconnect style is currently available only through intra-chip signal traces in `system-on-a-chip' implementations, as exemplified by embedded DRAMs. Because the traditional off-chip penalty in performance and wiring density is so large, a merging of complex process technologies is the only option today. It is suggested that, for system integration to move forward, the traditional robustness requirement inherited from conventional packaging interconnect and IC manufacturing test must be discarded. Traditional system assembly from vendor parts requires robustness under shipping, inspection and assembly. The trend toward systems on a chip signifies willingness by semiconductor companies to design and fabricate whole systems in house, so that `in-house' chip-to-chip assembly is not beyond reach. In this scenario, bare chips never leave the controlled environment of the IC fabricator while the two major contributors to off-chip signal penalty, ESD protection and the need to source a 50-ohm test head, are avoided. With in-house assembly, ESD protection can be eliminated with the precautions already familiar in plasma etching. Test interconnection impacts the fundamentals of IC manufacturing, particularly with clock speeds approaching 1GHz, and cannot be an afterthought. It should be an integral part of the chip-to-chip interconnection bandwidth optimization, because—as we must recognize—test is also performed using IC's. A system interconnection is proposed using multiple chips fabricated with conventional silicon processes, including MEMS technology. The system resembles an MCM that can be joined without committing to final assembly to perform at-speed testing. 50-Ohm test probes never load the circuit; only intended neighboring chips are ever connected. A `back-plane' chip provides the connection layers for both inter- and intra-chip signals and also serves as the probe card, in analogy with membrane probes now used for single-chip testing. Intra-chip connections, which require complicated connections during test that exactly match the product, are then properly made and all waveforms and loading conditions under test will be identical to those of the product. The major benefit is that all front-end chip technologies can be merged—logic, memory, RF, even passives. ESD protection is required only on external system connections. Manufacturing test information will accurately characterize process faults and thus avoid the Known-Good-Die problem that has slowed the arrival of conventional MCM's.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halbgewachs, Ronald D.; Chavez, Adrian R.
Process Control System (PCS) and Industrial Control System (ICS) security is critical to our national security. But there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. Sandia National Laboratories has performed the research and development of the OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy Office of Electricity Delivery and Energy Reliability (DOE/OE), to address this issue. OPSAID is an open-source architecture for PCS/ICS security that provides a design basis for vendors to build add-on security devices for legacy systems, whilemore » providing a path forward for the development of inherently-secure PCS elements in the future. Using standardized hardware, a proof-of-concept prototype system was also developed. This report describes the improvements and capabilities that have been added to OPSAID since an initial report was released. Testing and validation of this architecture has been conducted in another project, Lemnos Interoperable Security Project, sponsored by DOE/OE and managed by the National Energy Technology Laboratory (NETL).« less
Loukriz, Abdelhamid; Haddadi, Mourad; Messalti, Sabir
2016-05-01
Improvement of the efficiency of photovoltaic system based on new maximum power point tracking (MPPT) algorithms is the most promising solution due to its low cost and its easy implementation without equipment updating. Many MPPT methods with fixed step size have been developed. However, when atmospheric conditions change rapidly , the performance of conventional algorithms is reduced. In this paper, a new variable step size Incremental Conductance IC MPPT algorithm has been proposed. Modeling and simulation of different operational conditions of conventional Incremental Conductance IC and proposed methods are presented. The proposed method was developed and tested successfully on a photovoltaic system based on Flyback converter and control circuit using dsPIC30F4011. Both, simulation and experimental design are provided in several aspects. A comparative study between the proposed variable step size and fixed step size IC MPPT method under similar operating conditions is presented. The obtained results demonstrate the efficiency of the proposed MPPT algorithm in terms of speed in MPP tracking and accuracy. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Giri, S. N.; Hyde, D. M.
1988-01-01
The effects of polyinosinic-polycytidylic acid (Poly I:C), an inducer of interferons, on bleomycin (Bleo)-induced lung fibrosis was studied in hamsters. Poly I:C (10 mg/kg intraperitoneally) was administered for two days and immediately before intratracheal instillation of bleomycin (7.5 U/kg) or an equivalent volume of saline and thereafter daily for 13 days. The lung hydroxyproline in control, Poly I:C, Bleo, and Bleo + Poly I:C groups averaged 791, 752, 1177, and 766 micrograms/lung. As compared to control, the prolyl hydroxylase activity in the Bleo group was increased by 83% whereas in Bleo + Poly I:C group, the activity was increased by 42%. Protein in the bronchoalveolar lavage supernatant in Poly I:C, Bleo and Bleo + Poly I:C groups were 72, 286, and 206% of the control, respectively. There was no difference in total leukocyte counts between Bleo + Poly I:C and Bleo groups, but the differential cell counts were changed. The numbers of neutrophils, monocytes, lymphocytes, and eosinophils were 50, 84, 91, and 10% of Bleo group, respectively. Morphometric estimates of the volume of parenchymal lesion within the lung showed that hamsters in Bleo + Poly I:C group had significantly less volume of lesion (1.0 cucm) than the Bleo group (1.6 cucm). In addition, the fibrotic lesions in Bleo + Poly I:C group were multifocal and primarily proximal acinar in location, had fewer extracellular fibers, neutrophils and monocytes. Poly I:C treatment ameliorated bleomycin-induced lung collagen accumulation. Images Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 PMID:2462354
A combined chitosan/nano-size hydroxyapatite system for the controlled release of icariin.
Fan, Junjun; Bi, Long; Wu, Tao; Cao, Liangguo; Wang, Dexin; Nan, Kaihui; Chen, Jingdi; Jin, Dan; Jiang, Shan; Pei, Guoxian
2012-02-01
Icariin, a plant-derived flavonol glycoside, has been proved as an osteoinductive agent for bone regeneration. For this reason, we developed an icariin-loaded chitosan/nano-sized hydroxyapatite (IC-CS/HA) system which controls the release kinetics of icariin to enhance bone repairing. First, by Fourier transform infrared spectroscopy, we found that icariin was stable in the system developed without undergoing any chemical changes. On the other hand, X-ray diffraction, scanning electron microscopy and mechanical test revealed that the introduction of icariin did not remarkably change the phase, morphology, porosity and mechanical strength of the CS/HA composite. Then the hydrolytic degradation and drug release kinetics in vitro were investigated by incubation in phosphate buffered saline solution. The results indicated that the icariin was released in a temporally controlled manner and the release kinetics could be governed by degradation of both chitosan and hydroxyapatite matrix. Finally the in vitro bioactivity assay revealed that the loaded icariin was biologically active as evidenced by stimulation of bone marrow derived stroma cell alkaline phosphatase activity and formation of mineralized nodules. This successful IC-CS/HA system offers a new delivery method of osteoinductive agents and a useful scaffold design for bone regeneration.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Today's launch vehicles complex electronic and avionics systems heavily utilize Field Programmable Gate Array (FPGA) integrated circuits (IC) for their superb speed and reconfiguration capabilities. Consequently, FPGAs are prevalent ICs in communication protocols such as MILSTD- 1553B and in control signal commands such as in solenoid valve actuations. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
Present, future of automotive hybrid IC applications discussed
NASA Astrophysics Data System (ADS)
Matsuda, Nobuyoshi; Fukuoka, Atuhisa
1987-09-01
Hybrid ICs are presently utilized in various fields such as commercial televisions, VTRs, and audio devices, industrial usage of communication equipment, computers, terminals, and automobiles. Its applications and environments are various and diverse. The functions required for hybrid ICs vary from simple high density mounting for a system to the realization of high mechanisms with the application of function timing. The functions are properly used depending upon the system with its hybrid ICs and its circuit composition. Considering structure and reliability requirements for automotive hybrid ICs, an application example for hybrid ICs which use the package (COMPACT), will be discussed.
NASA Astrophysics Data System (ADS)
Sanz, D.; Ruiz, M.; Castro, R.; Vega, J.; Afif, M.; Monroe, M.; Simrock, S.; Debelle, T.; Marawar, R.; Glass, B.
2016-04-01
To aid in assessing the functional performance of ITER, Fission Chambers (FC) based on the neutron diagnostic use case deliver timestamped measurements of neutron source strength and fusion power. To demonstrate the Plant System Instrumentation & Control (I&C) required for such a system, ITER Organization (IO) has developed a neutron diagnostics use case that fully complies with guidelines presented in the Plant Control Design Handbook (PCDH). The implementation presented in this paper has been developed on the PXI Express (PXIe) platform using products from the ITER catalog of standard I&C hardware for fast controllers. Using FlexRIO technology, detector signals are acquired at 125 MS/s, while filtering, decimation, and three methods of neutron counting are performed in real-time via the onboard Field Programmable Gate Array (FPGA). Measurement results are reported every 1 ms through Experimental Physics and Industrial Control System (EPICS) Channel Access (CA), with real-time timestamps derived from the ITER Timing Communication Network (TCN) based on IEEE 1588-2008. Furthermore, in accordance with ITER specifications for CODAC Core System (CCS) application development, the software responsible for the management, configuration, and monitoring of system devices has been developed in compliance with a new EPICS module called Nominal Device Support (NDS) and RIO/FlexRIO design methodology.
Cookson, B; Mackenzie, D; Kafatos, G; Jans, B; Latour, K; Moro, M L; Ricchizzi, E; Van de Mortel, M; Suetens, C; Fabry, J
2013-09-01
Healthcare-associated infections in long-term care facilities (LTCFs) are of increasing importance. To develop consensus national performance indicators (NPIs) for infection control (ICPI) and antimicrobial stewardship (ASPI) in LTCFs, and assess the performance of 32 European countries against these NPIs. Previously established European standards were the basis for consensus and the same iterative approach with national representatives from the 32 countries. A World Health Organization scoring system recorded how close each country was to implementing each standard. The 42 agreed component indicators were grouped into six NPI categories: 'national programme', 'guidelines', 'expert advice', 'IC structure' (not present in the ASPI), 'surveillance' and 'composite'. 'Guidelines' scored the highest mean total possible score (60%, range 20-100%), followed by 'composite' (53%, range 30-100%), 'expert advice' (48%, range 20-100%), 'surveillance' (47%, range 20-83%), 'national programme' (42%, range 20-100%) and 'IC structure' (39%, range 20-100%). Although several scores were low, some countries were able to implement all NPIs, indicating that this was feasible. Most NPIs were very significantly related, indicating that they were considered to be important by the countries. 'Guidelines' and 'IC structure' were significantly related to European region (P ≤ 0.05). Accreditation/inspection was not evident in seven (22%) countries, nine (28%) countries had accreditation/inspection that included IC assessments, and seven (22%) countries had accreditation/inspection that included IC and antimicrobial stewardship assessments. Multi-variable analysis found that only the NPI and the ICPI 'expert advice' were associated with accreditation/inspection which included IC and antimicrobial stewardship. The identified gaps represent significant potential patient safety issues. The NPIs should serve as a basis for monitoring improvements over the coming years. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Post-Inhaled Corticosteroid Pulmonary Tuberculosis Increases Lung Cancer in Patients with Asthma
Lin, Frank Cheau-Feng; Nfor, Oswald Ndi; Jhang, Kai-Ming; Ku, Wen-Yuan; Ho, Chien-Chang; Lung, Chia-Chi; Pan, Hui-Hsien; Wu, Min-Chen; Wu, Ming-Fang; Liaw, Yung-Po
2016-01-01
Purpose To evaluate the association between post-inhaled corticosteroid (ICS) pulmonary tuberculosis (TB), pneumonia and lung cancer in patients with asthma. Methods The study samples were collected from the National Health Insurance Database. Asthmatic patients who were first-time users of ICS between 2003 and 2005 were identified as cases. For each case, 4 control individuals were randomly matched for sex, age and date of ICS use. Cases and matched controls were followed up until the end of 2010. Cox proportional hazard regression was used to determine the hazard ratio for pulmonary infections and lung cancer risk in the ICS users and non-users. Results A total of 10,904 first-time users of ICS were matched with 43,616 controls. The hazard ratios for lung cancer were: 2.52 (95% confidence interval [CI], 1.22–5.22; p = 0.012) for individuals with post-ICS TB, 1.28 (95%CI, 0.73–2.26; p = 0.389) for post-ICS pneumonia, 2.31(95%CI, 0.84–6.38; p = 0.105) for post-ICS pneumonia+TB, 1.08 (95%CI, 0.57–2.03; p = 0.815) for TB, 0.99 (95%CI, 0.63–1.55; p = 0.970) for pneumonia, and 0.32 (95%CI, 0.05–2.32; p = 0.261) for pneumonia+ TB, respectively. Conclusions Post-ICS TB increased lung cancer risk in patients with asthma. Because of the high mortality associated with lung cancer, screening tests are recommended for patients with post-ICS TB. PMID:27448321
Carlucci, J G; Jin, L; Sanders, J E; Mohapi, E Q; Mandalakas, A M
2015-03-21
A well-established pediatric human immunodeficiency virus (HIV) clinic in Lesotho with initial infection control (IC) measures prioritizing blood-borne disease. In line with international recommendations, services have been expanded to include the management of patients with tuberculosis (TB). The creation of comprehensive IC guidelines with an emphasis on TB has become a priority. To provide a model for developing and implementing IC guidelines in ambulatory care facilities in limited-resource settings with high HIV and TB prevalence. Activities: An IC plan that includes guidance covering both general IC measures and TB-specific guidelines was created by integrating local and international recommendations and emphasizing the importance of administrative measures, environmental controls, and disease-specific precautions. An interdisciplinary committee was established to oversee its implementation, monitoring, and evaluation. Development and implementation of IC guidelines in resource-limited settings are feasible and should be a priority in high HIV and TB prevalence areas. Education should be the cornerstone of such endeavors. Many interventions can be implemented with minimal expertise and material resources. Administrative support and institutional investment are essential to the sustainability of an effective IC program.
Schwalenberg, Thilo; Stolzenburg, Jens-Uwe; Ho, Thi Phuc; Mallock, Tobias; Hartenstein, Siegurd; Alexander, Henry; Zimmermann, Gerolf; Hohenfellner, Rudolf; Denzinger, Stefan; Burger, Maximilian; Horn, Lars-Christian; Neuhaus, Jochen
2012-06-01
Bladder pain syndrome/interstitial cystitis (BPS/IC) is associated with urothelial lesions. Pathomechanisms of urothelial damage and factors for urothelial restoration are unknown. hCG is a factor for cellular differentiation, angiogenesis and immune competence of the endometrium during pregnancy. Clinical observations demonstrate improvement of BPS/IC symptoms during pregnancy or during infertility treatment with hCG. Our research aims were to examine the expression of hCG and luteinizing hormone receptor (LHR) in the urothelium of BPS/IC patients and compare the levels of hCGβ with healthy controls. Bladder biopsies of BPS/IC (CLSM: n = 10; qPCR: n = 15); Tumour-free control tissue from cystectomies (n = 12). hCGα, hCGβ and LHR expression were examined by confocal laser scanning microscopy (CLSM), and hCGβ expression was quantified. hCGβ5 and hCGβ7 mRNA splice variants were quantified in real-time polymerase chain reaction. We found constitutive expression of hCGα, hCGβ and LHR in healthy controls. HCGβ was significantly upregulated in BPS/IC patients in CLSM. PCR analysis revealed higher levels of hCGβ7 than hCGβ5 in controls and BPS/IC patients. The constitutive expression of hCG and LHR speaks in favour for a functional signalling in urothelial cells without any association with either pregnancy or tumour. We show for the first time that hCGβ is upregulated in BPS/IC urothelium and that hCGβ7 is the dominant splice variant in those cells. Our findings imply a major role of hCG for urothelial integrity and a disturbance of hCG signalling in case of BPS/IC. We conclude that hCG could gain therapeutical relevance in the future.
Regional interoperability: making systems connect in complex disasters.
Briggs, Susan Miller
2009-08-01
Effective use of the Incident Command System (ICS) is the key to regional interoperability. Many different organizations with different command structures and missions respond to a disaster. The ICS allows different kinds of agencies (fire, police, and medical) to work together effectively in response to a disaster. Functional requirements, not titles, determine the organizational hierarchy of the ICS structure. The ICS is a modular/adaptable system for all disasters regardless of etiology and for all organizations regardless of size.
King, Stephanie L; Vanicek, Natalie; O'Brien, Thomas D
2017-06-01
Stair negotiation poses a substantial physical demand on the musculoskeletal system and this challenging task can place individuals at risk of falls. Peripheral arterial disease (PAD) can cause intermittent claudication (IC) pain in the calf and results in altered gait mechanics during level walking. However, whether those with PAD-IC adopt alternate strategies to climb stairs is unknown. Twelve participants with PAD-IC (six bilateral and six unilateral) and 10 healthy controls were recruited and instructed to ascend a five-step staircase whilst 3D kinematic data of the lower-limbs were recorded synchronously with kinetic data from force plates embedded into the staircase on steps two and three. Limbs from the unilateral group and both limbs from the bilateral claudicants were categorised as claudicating (N=18), asymptomatic (N=6) and control (N=10). Claudicants walked more slowly than healthy controls (trend; P=<0.066). Both claudicating- and asymptomatic-limb groups had reduced propulsive GRF (P=0.025 and P=0.002, respectively) and vertical GRF (P=0.005 and P=0.001, respectively) compared to controls. The claudicating-limb group had a reduced knee extensor moment during forward continuance (P=0.060), ankle angular velocity at peak moment (P=0.039) and ankle power generation (P=0.055) compared to the controls. The slower gait speed, irrespective of laterality of symptoms, indicates functional capacity was determined by the limitations of the claudicating limb. Reduced ankle power generation and angular velocity (despite adequate plantarflexor moment) implies velocity-dependent limitations existed in the calf. The lack of notable compensatory strategies indicates reliance on an impaired muscle group to accomplish this potentially hazardous task, highlighting the importance of maintaining plantarflexor strength and power in those with PAD-IC. Copyright © 2017 Elsevier B.V. All rights reserved.
Zelnick, Jennifer R; Gibbs, Andrew; Loveday, Marian; Padayatchi, Nesri; O'Donnell, Max R
2013-08-01
Drug-resistant tuberculosis (TB) is an occupational hazard for health-care workers (HCWs) in South Africa. We undertook this qualitative study to contextualize epidemiological findings suggesting that HCWs' elevated risk of drug-resistant TB is related to workplace exposure. A total of 55 HCWs and 7 hospital managers participated in focus groups and interviews about infection control (IC). Participants discussed caring for patients with drug-resistant TB, IC measures, occupational health programs, also stigma and support in the workplace. Key themes included: (i) lack of resources that hinders IC, (ii) distrust of IC efforts among HCWs, and (iii) disproportionate focus on individual-level personal protections, particularly N95 masks. IC programs should be evaluated, and the impact of new policies to rapidly diagnose drug-resistant TB and decentralize treatment should be assessed as part of the effort to control drug-resistant TB and create a safe workplace.
van Hell, Hendrika H; Bossong, Matthijs G; Jager, Gerry; Kahn, René S; Ramsey, Nick F
2011-03-01
Various lines of (pre)clinical research indicate that cannabinoid agents carry the potential for therapeutic application to reduce symptoms in several psychiatric disorders. However, direct testing of the involvement of cannabinoid brain systems in psychiatric syndromes is essential for further development. In the Pharmacological Imaging of the Cannabinoid System (PhICS) study, the involvement of the endocannabinoid system in cognitive brain function is assessed by comparing acute effects of the cannabinoid agonist Δ9-tetrahydrocannabinol (THC) on brain function between healthy controls and groups of psychiatric patients showing cognitive dysfunction. This article describes the objectives and methods of the PhICS study and presents preliminary results of the administration procedure on subjective and neurophysiological parameters. Core elements in the methodology of PhICS are the administration method (THC is administered by inhalation using a vaporizing device) and a comprehensive use of pharmacological magnetic resonance imaging (phMRI) combining several types of MRI scans including functional MRI (fMRI), Arterial Spin Labeling (ASL) to measure brain perfusion, and resting-state fMRI. Additional methods like neuropsychological testing further specify the exact role of the endocannabinoid system in regulating cognition. Preliminary results presented in this paper indicate robust behavioral and subjective effects of THC. In addition, fMRI paradigms demonstrate activation of expected networks of brain regions in the cognitive domains of interest. The presented administration and assessment protocol provides a basis for further research on the involvement of the endocannabionoid systems in behavior and in psychopathology, which in turn may lead to development of therapeutic opportunities of cannabinoid ligands. Copyright © 2011 John Wiley & Sons, Ltd.
SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ritter, T; Moran, J; Schultz, B
Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs atmore » 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, D.W.
This report contains a record of publishing and other activities in the Oak Ridge National Laboratory (ORNL) Instrumentation and Controls (I&C) Division for the period of July 1, 1994, to December31, 1997. It is a companion volume to Working Together on New Horizons: Instrumentation and Controls Division Progress Report for the Period of July 1, 1994, to December 31, 1997 (OR.NLA4-6530). Working Together on New Horizons contains illustrated summaries of some of the projects under way in I&C Division. Both books can be obtained by contacting C. R. Brittain (brittain@ornl. gov), P.O. Box 2008, Oak Ridge, TN 37831-6005. l&C Divisionmore » Mission and Vision I&C Division develops and maintains techniques, instruments, and systems that lead to a better understanding of nature and harnessing of natural phenomena for the benefit of humankind. We have dedicated ourselves to accelerating the advancement of science and the transfer of those advancements into products and processes that benefit U.S. industry and enhance the security of our citizens.« less
SPROC: A multiple-processor DSP IC
NASA Technical Reports Server (NTRS)
Davis, R.
1991-01-01
A large, single-chip, multiple-processor, digital signal processing (DSP) integrated circuit (IC) fabricated in HP-Cmos34 is presented. The innovative architecture is best suited for analog and real-time systems characterized by both parallel signal data flows and concurrent logic processing. The IC is supported by a powerful development system that transforms graphical signal flow graphs into production-ready systems in minutes. Automatic compiler partitioning of tasks among four on-chip processors gives the IC the signal processing power of several conventional DSP chips.
Artificial Diversity and Defense Security (ADDSec) Final Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chavez, Adrian R.; Hamlet, Jason; Stout, William M.S.
Critical infrastructure systems continue to foster predictable communication patterns and static configurations over extended periods of time. The static nature of these systems eases the process of gathering reconnaissance information that can be used to design, develop, and launch attacks by adversaries. In this research effort, the early phases of an attack vector will be disrupted by randomizing application port numbers, IP addresses, and communication paths dynamically through the use of overlay networks within Industrial Control Systems (ICS). These protective measures convert static systems into "moving targets," adding an additional layer of defense. Additionally, we have developed a framework thatmore » automatically detects and defends against threats within these systems using an ensemble of machine learning algorithms that classify and categorize abnormal behavior. Our proof-of-concept has been demonstrated within a representative ICS environment. Performance metrics of our proof-of-concept have been captured with latency impacts of less than a millisecond, on average.« less
Abousaad, S; Lassiter, K; Piekarski, A; Chary, P; Striplin, K; Christensen, K; Bielke, L R; Hargis, B M; Dridi, S; Bottje, W G
2017-05-01
Studies were conducted using a commercial InovojectTM system to determine effects of in ovo feeding of dextrin and iodinated casein (IC) on hatch and posthatch growth in broilers. At ∼18.5 d embryonic development, eggs were treated with 0, 240, or 480 μg IC/mL in saline (Cont, IC240, and IC480) or dextrin (Dext, DextIC240 and DextIC480). The Dext solution consisted of 18% maltodextrin and 10% potato starch dextrin; saline was the vehicle used by the company for in ovo vaccination. The volume for all in ovo treatments was 50 μL/injection. Eggs in Experiment 1 were transferred to a commercial hatcher unit whereas eggs in Experiments 2 and 3 were transferred to a research hatcher unit to assess effects of treatments on timing of hatch. At hatch, chicks were randomly selected and placed in floor pens and grown to 6 wk. In Experiment 1, there were no differences in hatch weights, but broilers provided Dext IC240 in ovo were heavier (P < 0.05) at 6 wk compared to other treatments with the exception of the Dext IC240 group. In Experiment 2, hatch weights were heavier (P < 0.05) in chicks receiving IC240 and DexIC480 treatments compared to Controls. At 6 wk, broilers in all treatments were heavier (P < 0.05) than Cont with the exception of IC480. In Experiment 3, hatch was stimulated by IC240 (in saline), but was delayed by Dext IC240. Serum analysis of β-hydroxybutyrate (μM/mL), as an indicator of ketone accumulation from fat metabolism of chicks held in chick boxes for 24 h posthatch (to simulate delay in placement after hatch), indicated that chicks in the IC240 group (that hatched earlier) had higher blood ketones compared to chicks that received Dext or DextIC240 in ovo (that hatched later). We conclude dextrin and iodinated casein (240 μg/mL) provided in ovo (∼18.5 d of embryonic development) has the potential to improve chick quality and posthatch body weight by delaying or narrowing hatch window. © 2016 Poultry Science Association Inc.
A Longitudinal Investigation of Conflict and Delay Inhibitory Control in Toddlers and Preschoolers
ERIC Educational Resources Information Center
Joyce, Amanda W.; Kraybill, Jessica H.; Chen, Nan; Cuevas, Kimberly; Deater-Deckard, Kirby; Bell, Martha Ann
2016-01-01
Research Findings: A total of 81 children participated in a longitudinal investigation of inhibitory control (IC) from 2 to 4 years of age. Child IC was measured via maternal report and laboratory measures under conditions of conflict and delay. Performance on delay IC tasks at 3 years was related to performance on these same tasks at 2 and…
Code of Federal Regulations, 2011 CFR
2011-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... Controller of Imports and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... Controller of Imports and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and...
1990-06-01
amplitude of the l IC actuators are set manually with no feedback of airframe response. Closed loop contrl refers to a system which utilizes response...mixture being controlled by the all position diaphragm carburetor and fuel pump . Ignition spark is ac-.cvd using " OX I mm spark plg. 28 b. Drive
Mod 1 ICS TI Report: ICS Conversion of a 140% HPGe Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bounds, John Alan
This report evaluates the Mod 1 ICS, an electrically cooled 140% HPGe detector. It is a custom version of the ORTEC Integrated Cooling System (ICS) modified to make it more practical for us to use in the field. Performance and operating characteristics of the Mod 1 ICS are documented, noting both pros and cons. The Mod 1 ICS is deemed a success. Recommendations for a Mod 2 ICS, a true field prototype, are provided.
Ichesco, Eric; Quintero, Andres; Clauw, Daniel J; Peltier, Scott; Sundgren, Pia M; Gerstner, Geoffrey E; Schmidt-Wilcke, Tobias
2012-03-01
Among the most common chronic pain conditions, yet poorly understood, are temporomandibular disorders (TMDs), with a prevalence estimate of 3-15% for Western populations. Although it is increasingly acknowledged that central nervous system mechanisms contribute to pain amplification and chronicity in TMDs, further research is needed to unravel neural correlates that might abet the development of chronic pain. The insular cortex (IC) and cingulate cortex (CC) are both critically involved in the experience of pain. The current study sought specifically to investigate IC-CC functional connectivity in TMD patients and healthy controls (HCs), both during resting state and during the application of a painful stimulus. Eight patients with TMD, and 8 age- and sex-matched HCs were enrolled in the present study. Functional magnetic resonance imaging data during resting state and during the performance of a pressure pain stimulus to the temple were acquired. Predefined seed regions were placed in the IC (anterior and posterior insular cortices) and the extracted signal was correlated with brain activity throughout the whole brain. Specifically, we were interested whether TMD patients and HCs would show differences in IC-CC connectivity, both during resting state and during the application of a painful stimulus to the face. As a main finding, functional connectivity analyses revealed an increased functional connectivity between the left anterior IC and pregenual anterior cingulate cortex (ACC) in TMD patients, during both resting state and applied pressure pain. Within the patient group, there was a negative correlation between the anterior IC-ACC connectivity and clinical pain intensity as measured by a visual analog scale. Since the pregenual region of the ACC is critically involved in antinociception, we hypothesize that an increase in anterior IC-ACC connectivity is indicative of an adaptation of the pain modulatory system early in the chronification process. © 2011 American Headache Society.
Godfrey, Catherine; Tauscher, Gail; Hunsberger, Sally; Austin, Melissa; Scott, Lesley; Schouten, Jeffrey T; Luetkemeyer, Anne F; Benson, Constance; Coombs, Robert; Swindells, Susan
2016-06-10
Health care associated transmission of Mycobacterium tuberculosis (TB) is well described. A previous survey of infection control (IC) practices at clinical research sites in low and middle income countries (LMIC) funded by the National Institute of Allergy and Infectious Diseases (NIAID) conducting HIV research identified issues with respiratory IC practices. A guideline for TB IC based on international recommendations was developed and promulgated. This paper reports on adherence to the guideline at sites conducting or planning to conduct TB studies with the intention of supporting improvement. A survey was developed that assessed IC activities in three domains: facility level measures, administrative control measures and environmental measures. An external site monitor visited each site in 2013-2014, to complete the audit. A central review committee evaluated the site-level survey and results were tabulated. Fisher's exact test was performed to determine whether there were significant differences in practices at sites that had IC officers versus sites that did not have IC officers. Significance was assessed at p=.05 RESULTS: Seven of thirty-three sites surveyed (22 %) had all the evaluated tuberculosis IC (TB IC) elements in place. Sixty-one percent of sites had an IC officer tasked with developing and maintaining TB IC standard operating procedures. Twenty-two (71 %) sites promptly identified and segregated individuals with TB symptoms. Thirty (93 %) sites had a separate waiting area for patients, and 26 (81 %) collected sputum within a specific well-ventilated area that was separate from the general waiting area. Sites with an IC officer were more likely to have standard operating procedures covering TB IC practices (p = 0.02) and monitor those policies (p = 0.02) and perform regular surveillance of healthcare workers (p = 0.02). The presence of an IC officer had a positive impact on performance in most of the TB IC domains surveyed including having adequate ventilation (p = 0.02) and a separate area for sputum collection (p = 0.02) CONCLUSIONS: Specific and targeted support of TB IC activities in the clinical research environment is needed and is likely to have a positive and sustained impact on preventing the transmission of TB to both health care workers and vulnerable HIV-infected research participants.
Stitch-bond parallel-gap welding for IC circuits
NASA Technical Reports Server (NTRS)
Chvostal, P.; Tuttle, J.; Vanderpool, R.
1980-01-01
Stitch-bonded flatpacks are superior to soldered dual-in-lines where size, weight, and reliability are important. Results should interest designers of packaging for complex high-reliability electronics, such as that used in security systems, industrial process control, and vehicle electronics.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Novack, Steven D.; Hatfield, Glen S.; Britton, Paul
2017-01-01
Today's launch vehicles complex electronic and avionic systems heavily utilize the Field Programmable Gate Array (FPGA) integrated circuit (IC). FPGAs are prevalent ICs in communication protocols such as MIL-STD-1553B, and in control signal commands such as in solenoid/servo valves actuations. This paper will demonstrate guidelines to estimate FPGA failure rates for a launch vehicle, the guidelines will account for hardware, firmware, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC, FPGA memory and clock. The firmware portion will provide guidelines on the high level FPGA programming language and ways to account for software/code reliability growth. The radiation portion will provide guidelines on environment susceptibility as well as guidelines on tailoring other launch vehicle programs historical data to a specific launch vehicle.
Pivnick, K A
1993-09-01
Trapping experiments were carried out near Saskatoon, Canada, from May through August 1990 to assess the response of the braconid wasp,Meteorus leviventris, to four selected mustard oils or isothiocyanates (IC) at a release rate of 4 mg/day, and for allyl IC only, at 40 mg/day. Only allyl IC at 4 mg/day was significantly attractive when trap captures were compared to the captures in the control traps. The others (n-propyl IC, 2-phenylethyl IC., and ethyl IC) were not attractive, nor was allyl IC at the higher dose, although trap captures with the latter bait were the second highest.
Chemistry and the Internal Combustion Engine II: Pollution Problems.
ERIC Educational Resources Information Center
Hunt, C. B.
1979-01-01
Discusses pollution problems which arise from the use of internal combustion (IC) engines in the United Kingdom (UK). The IC engine exhaust emissions, controlling IC engine pollution in the UK, and some future developments are also included. (HM)
Navarrete, Bernardino Alcázar; Palacios, Pedro José Romero; Aguilar-Salvatierra, Antonio; Guardia, Javier; Gómez-Moreno, Gerardo
2015-09-01
To date, no evidence exists in the literature as to the effects of inhaled corticosteroids (ICs) on salivary composition in patients with bronchial asthma. The aim of this study was to assess the effect of ICs on salival composition. Adult patients attending an outpatient respiratory clinic who were classified into two groups (controls and patients with bronchial asthma receiving ICs), were recruited in this cross-sectional study. For each participant, data of clinical records, baseline history of asthma, and regular IC dose were recorded. A sample of stimulated saliva was collected and processed for investigation of mucin 5B (MUC5B), lipoxygenase (LPO), total antioxidant capacity, and 8-hydroxydeoxyguanosine (8-OHdG) levels. Overall, 103 patients (49 controls and 54 patients receiving regular treatment with ICs) were recruited. No differences in comorbidities or smoking habits were observed. Patients treated with high-doses of ICs showed lower levels of salival MUC5B compared with those treated with medium IC doses or those not treated with ICs (1.60 vs. 2.20 vs. 2.53 ng/mL; p = 0.042). In patients with asthma, treatment with high-doses of ICs is associated with reduced levels of salivary MUC5B. This effect can explain some of the effects of ICs on oral health.
2013-01-01
Background Beckwith-Wiedemann syndrome (BWS) is a congenital overgrowth disorder associated with abnormalities in 11p15.5 imprinted genes. The most common cause is loss of methylation (epimutation) at the imprinting control centre 2 (IC2/KvDMR1). Most IC2 epimutations occur sporadically but an association with conception after assisted reproductive technologies (ART) has been reported. A subgroup of IC2 epimutation cases also harbour epimutations at other imprinting centres (ICs) outside of 11p15.5. We have investigated the relationship between these multiple epimutation cases (ME+), history of ART and clinical phenotype in a cohort of 187 BWS IC2 epimutation patients. Results Methylation analysis at PLAGL1, MEST and IGF2R ICs demonstrated an over-representation of patients with abnormally low methylation (8.5%, 12% and 6% respectively). At IGF2R some patients (2%) had gain of methylation but this was also detected in controls. Though there were no significant correlations between the methylation index (MIs) at the three ICs tested, a subset of patients appeared to be susceptible to multiple epimutations (ME+) and 21.2% of ME + patients had been conceived by ART compared to 4.5% (P = 0.0033) without additional epimutations. Methylation array profiling (Illumina Goldengate®) of patients and controls (excluding 11p15.5 loci) demonstrated significant differences between patients and controls. No significant associations were found between aspects of the BWS phenotype and individual epimutations but we describe a case presenting with a post-ART BWS-like phenotype in which molecular analysis demonstrated loss of paternal allele methylation at the 11p15.5 IC1 locus (IC1 regulates imprinting of IGF2 and H19). Loss of paternal allele methylation at the IC1 is the molecular finding associated with Silver-Russell syndrome whereas BWS is associated with gain of maternal allele methylation at IC1. Further analysis demonstrated epimutations at PLAGL1 and MEST consistent with the hypothesis that the presence of multiple epimutations may be of clinical relevance. Conclusions These findings suggest that the ME + subgroup of BWS patients are preferentially, but not exclusively, associated with a history of ART and that, though at present, there are no clear epigenotype-phenotype correlations for ME + BWS patients, non-11p15.5 IC epimutations can influence clinical phenotype. PMID:24325814
Wirschell, Maureen; Yang, Chun; Yang, Pinfen; Fox, Laura; Yanagisawa, Haru-aki; Kamiya, Ritsu; Witman, George B.; Porter, Mary E.
2009-01-01
Our goal is to understand the assembly and regulation of flagellar dyneins, particularly the Chlamydomonas inner arm dynein called I1 dynein. Here, we focus on the uncharacterized I1-dynein IC IC97. The IC97 gene encodes a novel IC without notable structural domains. IC97 shares homology with the murine lung adenoma susceptibility 1 (Las1) protein—a candidate tumor suppressor gene implicated in lung tumorigenesis. Multiple, independent biochemical assays determined that IC97 interacts with both α- and β-tubulin subunits within the axoneme. I1-dynein assembly mutants suggest that IC97 interacts with both the IC138 and IC140 subunits within the I1-dynein motor complex and that IC97 is part of a regulatory complex that contains IC138. Microtubule sliding assays, using axonemes containing I1 dynein but devoid of IC97, show reduced microtubule sliding velocities that are not rescued by kinase inhibitors, revealing a critical role for IC97 in I1-dynein function and control of dynein-driven motility. PMID:19420136
Retaining the equilibrium point hypothesis as an abstract description of the neuromuscular system.
Tresilian, J R
1999-01-01
The lambda version of the equilibrium point (EP) hypothesis for motor control is examined in light of recent criticisms of its various instantiations. Four important assumptions that have formed the basis for recent criticism are analyzed: First, the assumption that intact muscles possess invariant force-length characteristics (ICs). Second, that these ICs are of the same form in agonist-antagonist pairs. Third, that muscle control is monoparametric and that the control parameter, lambda, can be given a neurophysiological interpretation. Fourth, that reflex loop time delays and the known, asymmetric, nonlinear mechanical properties of muscles can be ignored. Mechanical and neurophysiological investigations of the neuromuscular system suggests that none of these assumptions is likely to be correct. This has been taken to mean that the EP hypothesis is oversimplified and a new approach is needed. It is argued that such an approach can be provided without rejecting the EP hypothesis, rather to regard it as an input-output description of muscle and associated segmental circuits. The operation of the segmental circuitry can be interpreted as having the function, at least in part, of compensating for a variety of nonlinearities and asymmetries such that the overall system implements the lambda-EP model equations.
Kühl, Susanne J.; Toberer, Matthias; Keis, Oliver; Tolks, Daniel; Fischer, Martin R.; Kühl, Michael
2017-01-01
Background: Medical students often have a problem recognising the relevance of basic science subjects for their later professional work in the pre-clinical stage of their studies. This can lead to a lower motivation to learn biochemical content and dissatisfaction in the courses amongst the students. Alternative teaching methods such as the Inverted Classroom (IC) method can address this deficiency. The goal of this study was: to analyse the motivation and satisfaction of the students in a biochemistry seminar through the use of the e-learning-based IC method, to investigate the acceptance against the IC teaching method in biochemistry, and to compare the learning success achieved using the IC approach with that of a traditional course. We also investigated how a biochemistry course in the pre-clinical stage of a human medicine course of studies can be successfully organised according to the IC method. Furthermore, we examined the benefits of the IC method over conventional teaching formats. Method: The IC method was implemented in accordance with the guidelines of the GMA committee “New Media” [30] in a biochemistry seminar for two student IC intervention groups with 42 students. A part of the factual knowledge from the on-site phase in the form of teaching videos together with self-learning control tasks were provided online before the seminar for both IC intervention groups. Exporting content to the self-learning phase creates new free time in the on-site phase, during which the content can be critically considered and processed and additional competency-based learning objectives can be taught. Identical biochemistry teaching content was taught in parallel control groups (14 student groups with n=299 students), but no material was handed out beforehand for a self-learning phase. These students only received the materials after the on-site phase. Motivation and satisfaction as well as the acceptance for the teaching methods were recorded by questionnaires, the acquisition of knowledge by MC exams. Results: On a Likert scale from 1 (strongly disagree) to 6 (strongly agree), the students in the IC intervention groups could be seen to be much more motivated (5.53) than students in the control group (4.01). Students in the IC intervention groups also recognised the relevance of the learning content much more clearly (5.44) than students in the control group (4.01). Furthermore, the IC group also observed that additional competencies were trained in addition to the biochemistry content. In addition, the IC intervention group award the event a school grade of 1.53, the traditional control group a grade of 2.96. The teaching videos were rated very positively by both groups with an average school grade of 1.3 in each case. A qualitative analysis showed that the motivation and a positive attitude of the lecturers played a decisive role in the successful implementation of the IC method. Discussion and conclusion: Pre-clinical students display a high acceptance of the e-learning-based IC method. Teaching communication competencies in a biochemistry seminar was also rated very positively by the students. The quality of the teaching video and the motivation of the lecturers were shown to be a critical parameter for the successful performance of the IC method. What’s more, the IC method can contribute to implementing a competence orientation in medical studies. PMID:28890922
Kühl, Susanne J; Toberer, Matthias; Keis, Oliver; Tolks, Daniel; Fischer, Martin R; Kühl, Michael
2017-01-01
Background: Medical students often have a problem recognising the relevance of basic science subjects for their later professional work in the pre-clinical stage of their studies. This can lead to a lower motivation to learn biochemical content and dissatisfaction in the courses amongst the students. Alternative teaching methods such as the Inverted Classroom (IC) method can address this deficiency. The goal of this study was: to analyse the motivation and satisfaction of the students in a biochemistry seminar through the use of the e-learning-based IC method, to investigate the acceptance against the IC teaching method in biochemistry, and to compare the learning success achieved using the IC approach with that of a traditional course. We also investigated how a biochemistry course in the pre-clinical stage of a human medicine course of studies can be successfully organised according to the IC method. Furthermore, we examined the benefits of the IC method over conventional teaching formats. Method: The IC method was implemented in accordance with the guidelines of the GMA committee "New Media" [30] in a biochemistry seminar for two student IC intervention groups with 42 students. A part of the factual knowledge from the on-site phase in the form of teaching videos together with self-learning control tasks were provided online before the seminar for both IC intervention groups. Exporting content to the self-learning phase creates new free time in the on-site phase, during which the content can be critically considered and processed and additional competency-based learning objectives can be taught. Identical biochemistry teaching content was taught in parallel control groups (14 student groups with n=299 students), but no material was handed out beforehand for a self-learning phase. These students only received the materials after the on-site phase. Motivation and satisfaction as well as the acceptance for the teaching methods were recorded by questionnaires, the acquisition of knowledge by MC exams. Results: On a Likert scale from 1 (strongly disagree) to 6 (strongly agree), the students in the IC intervention groups could be seen to be much more motivated (5.53) than students in the control group (4.01). Students in the IC intervention groups also recognised the relevance of the learning content much more clearly (5.44) than students in the control group (4.01). Furthermore, the IC group also observed that additional competencies were trained in addition to the biochemistry content. In addition, the IC intervention group award the event a school grade of 1.53, the traditional control group a grade of 2.96. The teaching videos were rated very positively by both groups with an average school grade of 1.3 in each case. A qualitative analysis showed that the motivation and a positive attitude of the lecturers played a decisive role in the successful implementation of the IC method. Discussion and conclusion: Pre-clinical students display a high acceptance of the e-learning-based IC method. Teaching communication competencies in a biochemistry seminar was also rated very positively by the students. The quality of the teaching video and the motivation of the lecturers were shown to be a critical parameter for the successful performance of the IC method. What's more, the IC method can contribute to implementing a competence orientation in medical studies.
System and method for floating-substrate passive voltage contrast
Jenkins, Mark W [Albuquerque, NM; Cole, Jr., Edward I.; Tangyunyong, Paiboon [Albuquerque, NM; Soden, Jerry M [Placitas, NM; Walraven, Jeremy A [Albuquerque, NM; Pimentel, Alejandro A [Albuquerque, NM
2009-04-28
A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.
NASA Technical Reports Server (NTRS)
Bose, Bimal K.; Kim, Min-Huei
1995-01-01
The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.
Status of infection control policies and organisation in European hospitals, 2001: the ARPAC study.
Struelens, M J; Wagner, D; Bruce, J; MacKenzie, F M; Cookson, B D; Voss, A; van den Broek, P J; Gould, I M
2006-08-01
Patient safety in hospital care depends on effective infection control (IC) programmes. The Antimicrobial Resistance Prevention and Control (ARPAC) study assessed the organisation, components and human resources of IC programmes in European hospitals. A questionnaire survey of policies and procedures implemented in 2001 for the surveillance and control of nosocomial infection and antibiotic resistance was completed by 169 acute-care hospitals from 32 European countries, categorised by five geographical regions. A formal IC programme existed in 72% of hospitals, and a multidisciplinary IC committee was operational in 90%. Trained IC nurses (ICNs) were present in 80% of hospitals (ranging from 54% in south-east and central-eastern Europe, to 100% in northern Europe), whereas 74% had one or more trained IC doctors (ICDs) (ranging from 46% in south-east Europe to 84% in western Europe). Median staffing levels were 2.33 ICNs/1,000 beds and 0.94 ICDs/1,000 beds. The intensity of IC programmes scored higher in centres from northern and western Europe than from other European regions. Written guidelines promoted hand hygiene for healthcare workers in 89% of hospitals, education in 85%, and audit in 46%. Guidelines recommended use of alcohol-based solutions (70%) and/or medicated/antiseptic soap (43%) for decontamination of non-soiled hands. Use of alcohol-based solutions varied according to region, from 41% in southern Europe to 100% in northern Europe, compared with use of medicated soap from 77% in southern Europe to 11% in northern Europe (p < 0.01). These findings showed that IC programmes in European hospitals suffer from major deficiencies in human resources and policies. Staffing levels for ICNs were below recommended standards in the majority of hospitals. Education programmes were incomplete and often not supported by audit of performance. Hand hygiene procedures were sub-standard in one-third of centres. Strengthening of IC policies in European hospitals should be a public health priority.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joe, Jeffrey .C; Boring, Ronald L.
Under the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program, researchers at Idaho National Laboratory (INL) have been using the Human Systems Simulation Laboratory (HSSL) to conduct critical safety focused Human Factors research and development (R&D) for the nuclear industry. The LWRS program has the overall objective to develop the scientific basis to extend existing nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure their long-term reliability, productivity, safety, and security. One focus area for LWRS is the NPP main control room (MCR), because many of the instrumentation andmore » control (I&C) system technologies installed in the MCR, while highly reliable and safe, are now difficult to replace and are therefore limiting the operating life of the NPP. This paper describes how INL researchers use the HSSL to conduct Human Factors R&D on modernizing or upgrading these I&C systems in a step-wise manner, and how the HSSL has addressed a significant gap in how to upgrade systems and technologies that are built to last, and therefore require careful integration of analog and new advanced digital technologies.« less
Shi, Linfan; Fu, Xiong; Tan, Chin Ping; Huang, Qiang; Zhang, Bin
2017-03-15
Ethylene gas was introduced into granular cold-water-soluble (GCWS) starches using a solid encapsulation method. The morphological and structural properties of the novel inclusion complexes (ICs) were characterized using scanning electron microscopy, X-ray diffractometry, and Raman spectroscopy. The V-type single helix of GCWS starches was formed through controlled gelatinization and ethanol precipitation and was approved to host ethylene gas. The controlled release characteristics of ICs were also investigated at various temperature and relative humidity conditions. Avrami's equation was fitted to understand the release kinetics and showed that the release of ethylene from the ICs was accelerated by increasing temperature or RH and was decelerated by increased degree of amylose polymerization. The IC of Hylon-7 had the highest ethylene concentration (31.8%, w/w) among the five starches, and the IC of normal potato starch showed the best controlled release characteristics. As a renewable and inexpensive material, GCWS starch is a desirable solid encapsulation matrix with potential in agricultural and food applications.
Motor Recovery After Subcortical Stroke Depends on Modulation of Extant Motor Networks.
Sharma, Nikhil; Baron, Jean-Claude
2015-01-01
Stroke is the leading cause of long-term disability. Functional imaging studies report widespread changes in movement-related cortical networks after stroke. Whether these are a result of stroke-specific cognitive processes or reflect modulation of existing movement-related networks is unknown. Understanding this distinction is critical in establishing more effective restorative therapies after stroke. Using multivariate analysis (tensor-independent component analysis - TICA), we map the neural networks involved during motor imagery (MI) and executed movement (EM) in subcortical stroke patients and age-matched controls. Twenty subcortical stroke patients and 17 age-matched controls were recruited. They were screened for their ability to carry out MI (Chaotic MI Assessment). The fMRI task was a right-hand finger-thumb opposition sequence (auditory-paced 1 Hz; 2, 3, 4, 5, 2…). Two separate runs were acquired (MI and rest and EM and rest; block design). There was no distinction between groups or tasks until the last stage of analysis, which allowed TICA to identify independent components (ICs) that were common or distinct to each group or task with no prior assumptions. TICA defined 28 ICs. ICs representing artifacts were excluded. ICs were only included if the subject scores were significant (for either EM or MI). Seven ICs remained that involved the primary and secondary motor networks. All ICs were shared between the stroke and age-matched controls. Five ICs were common to both tasks and three were exclusive to EM. Two ICs were related to motor recovery and one with time since stroke onset, but all were shared with age-matched controls. No IC was exclusive to stroke patients. We report that the cortical networks in stroke patients that relate to recovery of motor function represent modulation of existing cortical networks present in age-matched controls. The absence of cortical networks specific to stroke patients suggests that motor adaptation and other potential confounders (e.g., effort and additional muscle use) are not responsible for the changes in the cortical networks reported after stroke. This highlights that recovery of motor function after subcortical stroke involves preexisting cortical networks that could help identify more effective restorative therapies.
Emerson, C; Lipke, V; Kapata, N; Mwananyambe, N; Mwinga, A; Garekwe, M; Lanje, S; Moshe, Y; Pals, S L; Nakashima, A K; Miller, B
2016-07-01
Out-patient human immunodeficiency virus (HIV) care and treatment clinics in Zambia and Botswana, countries with a high burden of HIV and TB infection. To develop a tuberculosis infection control (TB IC) training and implementation package and evaluate the implementation of TB IC activities in facilities implementing the package. Prospective program evaluation of a TB IC training and implementation package using a standardized facility risk assessment tool, qualitative interviews with facility health care workers and measures of pre- and post-test performance. A composite measure of facility performance in TB IC improved from 32% at baseline to 50% at 1 year among eight facilities in Zambia, and from 27% to 80% at 6 months among 10 facilities in Botswana. Although there was marked improvement in indicators of managerial, administrative and environmental controls, key ongoing challenges remained in ensuring access to personal protective equipment and implementing TB screening in health care workers. TB IC activities at out-patient HIV clinics in Zambia and Botswana improved after training using the implementation package. Continued infrastructure support, as well as monitoring and evaluation, are needed to support the scale-up and sustainability of TB IC programs in facilities in low-resource countries.
Design and Analysis of Embedded I&C for a Fully Submerged Magnetically Suspended Impeller Pump
Melin, Alexander M.; Kisner, Roger A.
2018-04-03
Improving nuclear reactor power system designs and fuel-processing technologies for safer and more efficient operation requires the development of new component designs. In particular, many of the advanced reactor designs such as the molten salt reactors and high-temperature gas-cooled reactors have operating environments beyond the capability of most currently available commercial components. To address this gap, new cross-cutting technologies need to be developed that will enable design, fabrication, and reliable operation of new classes of reactor components. The Advanced Sensor Initiative of the Nuclear Energy Enabling Technologies initiative is investigating advanced sensor and control designs that are capable of operatingmore » in these extreme environments. Under this initiative, Oak Ridge National Laboratory (ORNL) has been developing embedded instrumentation and control (I&C) for extreme environments. To develop, test, and validate these new sensing and control techniques, ORNL is building a pump test bed that utilizes submerged magnetic bearings to levitate the shaft. The eventual goal is to apply these techniques to a high-temperature (700°C) canned rotor pump that utilizes active magnetic bearings to eliminate the need for mechanical bearings and seals. The technologies will benefit the Next Generation Power Plant, Advanced Reactor Concepts, and Small Modular Reactor programs. In this paper, we will detail the design and analysis of the embedded I&C test bed with submerged magnetic bearings, focusing on the interplay between the different major systems. Then we will analyze the forces on the shaft and their role in the magnetic bearing design. Next, we will develop the radial and thrust bearing geometries needed to meet the operational requirements of the test bed. In conclusion, we will present some initial system identification results to validate the theoretical models of the test bed dynamics.« less
Design and Analysis of Embedded I&C for a Fully Submerged Magnetically Suspended Impeller Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melin, Alexander M.; Kisner, Roger A.
Improving nuclear reactor power system designs and fuel-processing technologies for safer and more efficient operation requires the development of new component designs. In particular, many of the advanced reactor designs such as the molten salt reactors and high-temperature gas-cooled reactors have operating environments beyond the capability of most currently available commercial components. To address this gap, new cross-cutting technologies need to be developed that will enable design, fabrication, and reliable operation of new classes of reactor components. The Advanced Sensor Initiative of the Nuclear Energy Enabling Technologies initiative is investigating advanced sensor and control designs that are capable of operatingmore » in these extreme environments. Under this initiative, Oak Ridge National Laboratory (ORNL) has been developing embedded instrumentation and control (I&C) for extreme environments. To develop, test, and validate these new sensing and control techniques, ORNL is building a pump test bed that utilizes submerged magnetic bearings to levitate the shaft. The eventual goal is to apply these techniques to a high-temperature (700°C) canned rotor pump that utilizes active magnetic bearings to eliminate the need for mechanical bearings and seals. The technologies will benefit the Next Generation Power Plant, Advanced Reactor Concepts, and Small Modular Reactor programs. In this paper, we will detail the design and analysis of the embedded I&C test bed with submerged magnetic bearings, focusing on the interplay between the different major systems. Then we will analyze the forces on the shaft and their role in the magnetic bearing design. Next, we will develop the radial and thrust bearing geometries needed to meet the operational requirements of the test bed. In conclusion, we will present some initial system identification results to validate the theoretical models of the test bed dynamics.« less
2015-02-01
not normally blocked by enterprise firewalls . • Some malware exploited zero-day vulnerabilities as well as attempted to exploit vulnerabilities for...servers, receiving updates, and exfiltrating data. Firewalls are routinely configured to block incoming connections while malware within a target...implemented with layers of technical security controls (e.g., ICS-aware firewalls ) to control network traffic and prevent the spread of malware . Intrusion
DiSantostefano, Rachael L; Davis, Kourtney J
2011-06-01
An association between salmeterol, a long-acting β(2)-agonist (LABA), use and rare serious asthma events or asthma mortality was observed in two large clinical trials. This has resulted in heightened scrutiny of LABAs and comprehensive reviews by regulatory agencies. The aim of this retrospective observational cohort study was to better characterize salmeterol medication use patterns in the UK. We describe asthma prescription patterns in a cohort of patients (n =17,745) in the General Practice Research Database who initiated treatment with salmeterol-containing prescriptions between 2003 and 2006, including salmeterol and salmeterol/fluticasone propionate in a single device. Prescriptions patterns by medication class, including concurrent prescription of salmeterol with inhaled corticosteroids (ICS), were described using 6-month intervals in the 1-year period before and after the salmeterol-containing index prescription. In the 0- to 6-month and 7- to 12-month periods prior to initiation of the salmeterol-containing prescription, the cohort experienced worsening of asthma, measured by an increase in the proportion of patients with prescriptions for short-acting β-agonists [SABA] (73-89%), ICS (70-81%) and systemic corticosteroids (14-28%). Nearly all patients prescribed salmeterol were concurrently prescribed ICS (≥95% within 90 days). In the 12 months following initiation of the salmeterol-containing prescription, a decrease in asthma prescriptions was observed. These results support the appropriate prescribing of salmeterol-containing medications, as per recommendations in asthma treatment guidelines in the UK. Salmeterol was consistently prescribed as an add-on asthma-controller with an ICS for most patients, and was associated with improvements in asthma control, as indicated by decreases in SABA and systemic corticosteroid prescriptions following salmeterol introduction.
Temporal and developmental requirements for the Prader–Willi imprinting center
DuBose, Amanda J.; Smith, Emily Y.; Johnstone, Karen A.; Resnick, James L.
2012-01-01
Imprinted gene expression associated with Prader–Willi syndrome (PWS) and Angelman syndrome (AS) is controlled by two imprinting centers (ICs), the PWS-IC and the AS-IC. The PWS-IC operates in cis to activate transcription of genes that are expressed exclusively from the paternal allele. We have created a conditional allele of the PWS-IC to investigate its developmental activity. Deletion of the paternal PWS-IC in the embryo before implantation abolishes expression of the paternal-only genes in the neonatal brain. Surprisingly, deletion of the PWS-IC in early brain progenitors does not affect the subsequent imprinted status of PWS/AS genes in the newborn brain. These results indicate that the PWS-IC functions to protect the paternal epigenotype at the epiblast stage of development but is dispensable thereafter. PMID:22331910
Power, Sarah D; Kushki, Azadeh; Chau, Tom
2011-12-01
Near-infrared spectroscopy (NIRS) has recently been investigated as a non-invasive brain-computer interface (BCI) for individuals with severe motor impairments. For the most part, previous research has investigated the development of NIRS-BCIs operating under synchronous control paradigms, which require the user to exert conscious control over their mental activity whenever the system is vigilant. Though functional, this is mentally demanding and an unnatural way to communicate. An attractive alternative to the synchronous control paradigm is system-paced control, in which users are required to consciously modify their brain activity only when they wish to affect the BCI output, and can remain in a more natural, 'no-control' state at all other times. In this study, we investigated the feasibility of a system-paced NIRS-BCI with one intentional control (IC) state corresponding to the performance of either mental arithmetic or mental singing. In particular, this involved determining if these tasks could be distinguished, individually, from the unconstrained 'no-control' state. Deploying a dual-wavelength frequency domain near-infrared spectrometer, we interrogated nine sites around the frontopolar locations (International 10-20 System) while eight able-bodied adults performed mental arithmetic and mental singing to answer multiple-choice questions within a system-paced paradigm. With a linear classifier trained on a six-dimensional feature set, an overall classification accuracy of 71.2% across participants was achieved for the mental arithmetic versus no-control classification problem. While the mental singing versus no-control classification was less successful across participants (62.7% on average), four participants did attain accuracies well in excess of chance, three of which were above 70%. Analyses were performed offline. Collectively, these results are encouraging, and demonstrate the potential of a system-paced NIRS-BCI with one IC state corresponding to either mental arithmetic or mental singing.
NASA Astrophysics Data System (ADS)
Power, Sarah D.; Kushki, Azadeh; Chau, Tom
2011-10-01
Near-infrared spectroscopy (NIRS) has recently been investigated as a non-invasive brain-computer interface (BCI) for individuals with severe motor impairments. For the most part, previous research has investigated the development of NIRS-BCIs operating under synchronous control paradigms, which require the user to exert conscious control over their mental activity whenever the system is vigilant. Though functional, this is mentally demanding and an unnatural way to communicate. An attractive alternative to the synchronous control paradigm is system-paced control, in which users are required to consciously modify their brain activity only when they wish to affect the BCI output, and can remain in a more natural, 'no-control' state at all other times. In this study, we investigated the feasibility of a system-paced NIRS-BCI with one intentional control (IC) state corresponding to the performance of either mental arithmetic or mental singing. In particular, this involved determining if these tasks could be distinguished, individually, from the unconstrained 'no-control' state. Deploying a dual-wavelength frequency domain near-infrared spectrometer, we interrogated nine sites around the frontopolar locations (International 10-20 System) while eight able-bodied adults performed mental arithmetic and mental singing to answer multiple-choice questions within a system-paced paradigm. With a linear classifier trained on a six-dimensional feature set, an overall classification accuracy of 71.2% across participants was achieved for the mental arithmetic versus no-control classification problem. While the mental singing versus no-control classification was less successful across participants (62.7% on average), four participants did attain accuracies well in excess of chance, three of which were above 70%. Analyses were performed offline. Collectively, these results are encouraging, and demonstrate the potential of a system-paced NIRS-BCI with one IC state corresponding to either mental arithmetic or mental singing.
He, Chun-Hui; Li, Xing; Lin, Jun-Hong; Xiao, Qiang; Yu, Jia-Lu; Liu, Ying-Fen; Jiang, Wen-Hui; Chen, Chen; Deng, Li; Zhou, Jie
2017-12-01
Inhaled corticosteroids (ICSs) for treating asthma are controversial because of their negative effects on the growth of asthmatic children and without clearly defined withdrawal strategy. A 2-year ICS step-down and withdrawal strategy has been developed for asthmatic children receiving 3-year subcutaneous immunotherapy (SCIT). Eleven children were included into the SCIT group and 13 children into the ICS group. ICSs were discontinued when children met the following criteria: requiring only 1 puffper day, with good control, for at least 6 months; having a forced expiratory volume in 1 second (FEV 1 )/forced vital capacity ≥80%; and SCIT discontinued for ≥24 months. The main endpoints were the results of both the childhood asthma control test (C-CAT) and the methacholine bronchial provocation test. In the SCIT group, all the 11 children had ICS discontinued, with one child developed asthma attack after pneumonia and received ICS again after completion of SCIT. In the ICS group, five children discontinued ICS and developed asthma attacks later and received ICS again; the other eight children developed severe symptoms during ICS step-down. Thus, the discontinuation of ICS was only achieved in the SCIT group. The dose of methacholine that caused a decrease of 20% in FEV 1 continued to improve after discontinuation of ICS for the SCIT group and presented better results than the ICS group (P=0.050). After completion of SCIT, the C-CAT had improved significantly after 30 months of treatment compared with the ICS group (P<0.05). In the present study, we developed a 2-year step-down and withdrawal strategy from ICSs strategy for allergic asthma children receiving SCIT; the strategy was efficacious and safe.
An acute bout of localized resistance exercise can rapidly improve inhibitory control
Tsukamoto, Hayato; Suga, Tadashi; Takenaka, Saki; Takeuchi, Tatsuya; Tanaka, Daichi; Hamaoka, Takafumi; Hashimoto, Takeshi; Isaka, Tadao
2017-01-01
The positive effect of acute resistance exercise on executive function, such as inhibitory control (IC), is poorly understood. Several previous studies have demonstrated this effect using whole-body resistance exercise. However, it remains unclear whether localized resistance exercise performed using only limited muscle groups could also acutely improve IC. Thus, the present study examined the effect of an acute bout of localized resistance exercise on IC. Twelve healthy men performed a color-word Stroop task (CWST) before and immediately after the experimental conditions, which consisted of 2 resistance exercises and a resting control (CON). Bilateral knee extension was used to create 2 resistance exercise conditions: light-intensity resistance exercise (LRE) and high-intensity resistance exercise (HRE) conditions, which were 40% and 80% of one-repetition maximum, respectively. The resistance exercise session was programmed for 6 sets with 10 repetitions per set. The CWST-measured IC was significantly improved immediately after both LRE and HRE, but it did not improve immediately after CON. However, the improved IC was significantly greater in HRE than in LRE. The present findings showed that IC could be rapidly improved by an acute bout of localized resistance exercise, especially with high-intensity. Therefore, we suggest that in addition to whole-body resistance exercise, localized resistance exercise performed using limited muscle groups may be sufficient for improving IC. PMID:28877232
Organization of infection control in European hospitals.
Hansen, S; Zingg, W; Ahmad, R; Kyratsis, Y; Behnke, M; Schwab, F; Pittet, D; Gastmeier, P
2015-12-01
The Prevention of Hospital Infections by Intervention and Training (PROHIBIT) survey was initiated to investigate the status of healthcare-associated infection (HCAI) prevention across Europe. This paper presents the methodology of the quantitative PROHIBIT survey and outlines the findings on infection control (IC) structure and organization including management's support at the hospital level. Hospitals in 34 countries were invited to participate between September 2011 and March 2012. Respondents included IC personnel and hospital management. Data from 309 hospitals in 24 countries were analysed. Hospitals had a median (interquartile range) of four IC nurses (2-6) and one IC doctor (0-2) per 1000 beds. Almost all hospitals (96%) had defined IC objectives, which mainly addressed hand hygiene (87%), healthcare-associated infection reduction (84%), and antibiotic stewardship (66%). Senior management provided leadership walk rounds in about half of hospitals, most often in Eastern and Northern Europe, 65% and 64%, respectively. In the majority of hospitals (71%), sanctions were not employed for repeated violations of IC practices. Use of sanctions varied significantly by region (P < 0.001), but not by countries' healthcare expenditure. There is great variance in IC staffing and policies across Europe. Some areas of practice, such as hand hygiene, seem to receive considerably more attention than others that are equally important, such as antibiotic stewardship. Programmes in IC suffer from deficiencies in human resources and local policies, ubiquitous factors that negatively impact on IC effectiveness. Strengthening of IC policies in European hospitals should be a public health priority. Copyright © 2015. Published by Elsevier Ltd.
Inhaled versus systemic corticosteroids for acute asthma in children. A systematic review.
Beckhaus, Andrea A; Riutort, Maria C; Castro-Rodriguez, Jose A
2014-04-01
To compare the effects of inhaled corticosteroids (ICS) against systemic corticosteroids (SC) in children consulting in emergency department (ED) or equivalent for asthma exacerbation. Electronic search in MEDLINE, CENTRAL, CINAHL, and LILACS databases and other sources. Study selection criteria: children 2-18 years of age, consulting in ED or equivalent for asthma exacerbation, comparison between ICS and SC, randomized controlled trials. hospital admission rate, unscheduled visits for asthma symptoms, need of additional course of SC. improvement of lung function, length of stay in ED, clinical scores, and adverse effects. Eight studies met inclusion criteria (N = 797), published between 1995 and 2006. All used prednisolone as SC and budesonide, fluticasone, dexamethasone, and flunisolide were administered as ICS. No significant difference between ICS versus SC was found in terms of hospital admission (RR: 1.02; 95% CI: 0.41-2.57), unscheduled visits for asthma symptoms (RR: 9.55; 95% CI: 0.53-170.52) nor for need of additional course of SC (RR: 1.45; 95% CI: 0.28-7.62). The change in % of predicted FEV1 at fourth hour was significantly higher for SC group, but there was no significant difference between both groups after this time. There was insufficient data to perform meta-analysis of length of stay during first consult in ED and of symptom scores. Vomiting was similar among both groups. There is no evidence of a difference between ICS and SC in terms of hospital admission rates, unscheduled visits for asthma symptoms and need of additional course of SC in children consulting for asthma exacerbations. © 2013 Wiley Periodicals, Inc.
Correlation Between Bladder Pain Syndrome/Interstitial Cystitis and Pelvic Inflammatory Disease
Chung, Shiu-Dong; Chang, Chao-Hsiang; Hung, Peir-Haur; Chung, Chi-Jung; Muo, Chih-Hsin; Huang, Chao-Yuan
2015-01-01
Abstract Pelvic inflammatory disease (PID) has been investigated in Western countries and identified to be associated with chronic pelvic pain and inflammation. Bladder pain syndrome/interstitial cystitis (BPS/IC) is a complex syndrome that is significantly more prevalent in women than in men. Chronic pelvic pain is a main symptom of BPS/IC, and chronic inflammation is a major etiology of BPS/IC. This study aimed to investigate the correlation between BPS/IC and PID using a population-based dataset. We constructed a case–control study from the Taiwan National Health Insurance program. The case cohort comprised 449 patients with BPS/IC, and 1796 randomly selected subjects (about 1:4 matching) were used as controls. A Multivariate logistic regression model was constructed to estimate the association between BPS/IC and PID. Of the 2245 sampled subjects, a significant difference was observed in the prevalence of PID between BPS/IC cases and controls (41.7% vs 15.4%, P < 0.001). Multivariate logistic regression analysis revealed that the odds ratio (OR) for PID among cases was 3.69 (95% confidence interval [CI]: 2.89–4.71). Furthermore, the ORs for PID among BPS/IC cases were 4.52 (95% CI: 2.55–8.01), 4.31 (95% CI: 2.91–6.38), 3.00 (95% CI: 1.82–4.94), and 5.35 (95% CI: 1.88–15.20) in the <35, 35–49, 50–64, and >65 years age groups, respectively, after adjusting for geographic region, irritable bowel syndrome, and hypertension. Joint effect was also noted, specifically when patients had both PID and irritable bowel disease with OR of 10.5 (95% CI: 4.88–22.50). This study demonstrated a correlation between PID and BPS/IC. Clinicians treating women with PID should be alert to BPS/IC-related symptoms in the population. PMID:26579800
Strategy to Ensure Institutional Control Implementation at Superfund Sites
This document sets forth EPA’s strategy (Strategy) for ensuring that institutional controls (ICs) are successfully implemented at Superfund sites, with an emphasis on evaluating ICs at sites where all construction of all remedies is complete (construction complete sites).
Outcomes using exhaled nitric oxide measurements as an adjunct to primary care asthma management.
Hewitt, Richard S; Modrich, Catherine M; Cowan, Jan O; Herbison, G Peter; Taylor, D Robin
2009-12-01
Exhaled nitric oxide (FENO) measurements may help to highlight when inhaled corticosteroid (ICS) therapy should or should not be adjusted in asthma. This is often difficult to judge. Our aim was to evaluate a decision-support algorithm incorporating FENO measurements in a nurse-led asthma clinic. Asthma management was guided by an algorithm based on high (>45ppb), intermediate (30-45ppb), or low (<30ppb) FENO levels and asthma control status. This provided for one of eight possible treatment options, including diagnosis review and ICS dose adjustment. Well controlled asthma increased from 41% at visit 1 to 68% at visit 5 (p=0.001). The mean fluticasone dose decreased from 312 mcg/day at visit 2 to 211mcg/day at visit 5 (p=0.022). There was a high level of protocol deviations (25%), often related to concerns about reducing the ICS dose. The % fall in FENO associated with a change in asthma status from poor control to good control was 35%. An FENO-based algorithm provided for a reduction in ICS doses without compromising asthma control. However, the results may have been influenced by the education and support which patients received. Reluctance to reduce ICS dose was an issue which may have influenced the overall results. Australian Clinical Trials Registry # 012605000354684.
Lee, Jane-Dar; Lee, Ming-Huei
2014-01-01
Unique barrier properties of the urothelial surface membrane permit urine storage without contents leak into the bloodstream. Previous reports suggested that the bladder urothelial barrier might be compromised in interstitial cystitis/painful bladder syndrome (IC/PBS). We examined the changes of tight junction proteins (zonula occludens-1 (ZO-1) and occludin) in IC/PBS patients. Bladder samples were derived from of 32 patients with IC/PBS and eight controls. We detected the tight junction proteins of ZO-1 and occludin expression by immunoblotting, immunohistochemical (IHC) staining and double immunofluorescent (IF) staining with confocal microscopy. Data were analyzed using the Mann-Whitney U-test. Expression of ZO-1 and occludin in the IC/PBS group was reduced compared to the control group by immunoblotting and IHC staining. Also, the thinning and denudation of urothelium were demonstrated in the IC/PBS group by histological study. IF staining showed the interruption of bladder urothelium in IC/PBS patients under confocal microscopy. Our data showed that decreased expression of tight junction proteins (ZO-1 and occludin) and interruption of bladder urothelium in IC/PBS patients. Treatment to repair the discontinuous urothelium may be useful to relieve some clinical symptoms of patients with IC/PBS. Copyright © 2012. Published by Elsevier B.V.
Urban adults' perceptions of factors influencing asthma control.
George, Maureen; Keddem, Shimrit; Barg, Frances K; Green, Sarah; Glanz, Karen
2015-02-01
To identify urban adults' perceptions of facilitators and barriers to asthma control, including the role of self-care, medications, environmental trigger remediation, and primary care. Semi-structured open-ended qualitative interviews were conducted. Audio recordings were transcribed verbatim and entered into NVivo 10.0 (QSR International Pty Ltd, Doncaster, Victoria, Australia) for coding, analysis, and integration with demographic and asthma control data. RESULTS were analyzed by the level of asthma control. A modified grounded theory approach was used in the analysis. Thirty-five adults with persistent asthma (94% Black; 71% female; 71% with uncontrolled asthma) from the five West Philadelphia zip codes with the highest asthma burden participated. Generally, all participants understood the roles of inhaled corticosteroid (ICS) and short-acting β-2 agonist (SABA) therapies in asthma self-care although they attributed systemic side effects to topical ICS administration. Compared with participants with controlled asthma, uncontrolled participants reported overusing SABAs, underusing ICS, rejecting medical and trigger remediation advice, having more negative experiences with primary care providers, and preferring more unconventional strategies to prevent or manage asthma symptoms. Personal health beliefs about control can undermine adherence to medical and environmental remediation advice and likely contributes to high rates of uncontrolled asthma in this population. Clinicians need to know whether, and to what degree, these health beliefs can be modified. It is likely that new models of care, such as patient-centered shared decision-making approaches, and new partners, such as community health workers, may be required to modify these beliefs. This would be an important first step to enhance asthma control in vulnerable populations.
Nosocomial tuberculosis prevention in Portuguese hospitals: a cross-sectional evaluation.
Sousa, M; Gomes, M; Gaio, A R; Duarte, R
2017-08-01
Measures to control tuberculous infection are crucial to prevent nosocomial transmission and protect health care workers (HCWs). In Portugal, the extent of implementation of tuberculosis (TB) control measures in hospitals is not known. To determine the current implementation of preventive measures for tuberculous infection at administrative, environmental and personal levels in Portuguese hospitals. A cross-sectional evaluation was performed using two anonymous questionnaires: one sent to all the hospital infection control (IC) committees and the other sent to all pulmonologists and physicians specialising in infectious disease. Fourteen IC committees and 72 physicians responded. According to the IC committees, 92% of hospitals had a written TB control plan, but only 37% of the physicians said there was always/almost always a fast track for diagnosing suspected pulmonary TB cases. The majority of the hospitals had an isolation policy (85%) and these patients were always/almost always admitted in separate rooms, according to 70% of physicians. Both HCWs and TB patients used respiratory protection equipment (92%). These findings indicate that the most basic TB IC measures had been undertaken, but some TB IC measures were not fully implemented at all hospitals. An institutional effort should be made to solve this problem and strengthen TB prevention activities.
NASA Astrophysics Data System (ADS)
Rahman, Ataur; Sharif, Sazzad; Mohiuddin, AKM; Faris Ismail, Ahmed; Izan, Sany Ihsan
2017-03-01
Continuously variable transmission (CVT) system transmits the engine /battery power to the car driving wheel smoothly and efficiently. Cars with CVT produces some noise and slow acceleration to meet the car power demand on initial start-ups and slow speed. The car noise is produced as a result of CVT adjustment the engine speed with the hydraulic pressure. The current CVT problems incurred due to the slow response of hydraulic pressure and CVT fluid viscosity due to the development of heat.The aim of this study is to develop electromagnetic actuated CVT (EMA-CVT) with intelligent switching controlling system (ICS). The experimental results of ¼ scale EMA shows that it make the acceleration time of the car in 3.5-5 sec which is 40% less than the hydraulic CVT in the market. The EMA develops the electromagnetic force in the ranged of 350 -1200 N for the supply current in the range of 10-15 amp. This study introduced fuzzy intelligent system (FIS) to predict the EMA system dynamic behaviour in order to identify the current control for the EMA actuation during operation of the CVT. It is expecting that the up scale EMA-CVT would reduce the 75% of vehicle power transmission loss by accelerating vehicle in 5 sec and save the IC engine power consumption about 20% which will makes the vehicle energy efficient (EEV) and reduction of green house gas reduction.
Conflict Inhibitory Control Facilitates Pretense Quality in Young Preschoolers
ERIC Educational Resources Information Center
Van Reet, Jennifer
2015-01-01
The present research explores the role of inhibitory control (IC) in young preschoolers' pretense ability using an ego depletion paradigm. In Experiment 1 (N = 56), children's pretense ability was assessed either before or after participating in conflict IC or control tasks, and in Experiment 2 (N = 36), pretense ability was measured after…
Visible, Durable, Enforceable Institutional Controls: Weldon Spring Site - A 10-Year Journey - 13190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uhlmeyer, Terri; Thompson, Randy; Starr, Ken
2013-07-01
The DOE Office of Legacy Management's (LM's) mission is to manage the DOE's post-closure responsibilities and ensure the future protection of human health and the environment. LM has control and custody of legacy land, structures, and facilities and is responsible for maintaining them at levels suitable for their long-term use. This includes all engineered and institutional controls (ICs) designed as another level of assurance to prevent exposure to residual contamination and waste. The development and management of ICs has been, and continues to be, a critical component to the success of LM surveillance and maintenance activities. Many major federal laws,more » Executive Orders, regulations, and various other drivers influence the establishment and use of ICs at LM sites. LM uses a wide range of ICs to appropriately limit access to, or uses of, land, facilities, and other real and personal properties; protect the environment; maintain the physical safety and security of DOE facilities; and prevent or limit inadvertent human and environmental exposure to residual contaminants and other hazards. The ICs at the Weldon Spring, Missouri, Site were developed in close coordination with federal and state regulators. An Explanation of Significant Differences (ESD) was issued in February 2005, which clarified the use restrictions necessary for the remedial actions specified in the Records of Decision for the separate operable units to remain protective over the long-term. The operable units included the Chemical Plant Operable Unit, the Chemical Plant Groundwater Operable Unit, and the Quarry Residuals Operable Unit. The ESD clarified specific requirements for each site area that needed use restrictions and established how DOE would implement, maintain, and monitor the specific requirements. DOE developed the Long-Term Surveillance and Maintenance Plan for the U.S. Department of Energy Weldon Spring, Missouri, Site (LTS and M Plan) that addressed the full scope of the site management activities necessary to ensure that the Weldon Spring Site remains protective over the long-term. The LTS and M Plan is revised periodically to ensure its applicability to changing site, regulatory, or procedural conditions. In addition to addressing such activities as long-term groundwater monitoring and disposal cell maintenance, the LTS and M Plan was developed and issued to ensure that the use restrictions identified in the ESD were properly imposed and maintained. The LTS and M Plan included a detailed IC Implementation Plan, which includes a process for evaluating and identifying specific IC mechanisms that best accomplish the objectives set out in the ESD. Consistent with EPA guidance on selecting ICs, various IC mechanisms were evaluated, including government controls, proprietary controls, enforcement tools, and informational devices. Where appropriate, redundant mechanisms were employed to increase the effectiveness of the ICs. Information in the IC Implementation Plan includes: (1) a discussion of current site conditions (reflecting post-remedial action conditions for the Chemical Plant and Quarry Areas and the risk-basis for why use restrictions are needed); (2) the objectives of, or performance expectations for, the use restrictions; (3) specific ICs already in place and additional mechanisms identified for implementation; (4) a schedule for implementing additional ICs; (5) procedures for maintaining the ICs and for conducting periodic inspections; and (6) general provisions for the implementing ICs for the site. The actual agreements and documentation of the various ICs are included in an appendix of the LTS and M Plan. These documents are also available via the internet from the authorizing agencies (County, Missouri Department of Natural Resources, EPA, etc.) The Weldon Spring Site personnel have been successful in finalizing each of the ICs that were established for the site. The planning, establishment, and implementation of the ICs was a long and detailed process with several lessons-learned that were identified along the way. (authors)« less
Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS)
2012-05-01
protect, and secure the United States and its interests. • AOF is the United States, Alaska, Canada, Mexico, Bahamas, Puerto Rico , and the U.S. Virgin...Criteria (UFC) for Smart Microgrid Cyber design guides for Industrial Control Systems (ICS) Residual systems Operations and Maintenance Operator...Training Sustainment Commercial Transition Cooperation with NIST for microgrid security standards Working with industry associations and
Ribassin-Majed, Laureen; Marguet, Sophie; Lee, Anne W.M.; Ng, Wai Tong; Ma, Jun; Chan, Anthony T.C.; Huang, Pei-Yu; Zhu, Guopei; Chua, Daniel T.T.; Chen, Yong; Mai, Hai-Qiang; Kwong, Dora L.W.; Cheah, Shie-Lee; Moon, James; Tung, Yuk; Chi, Kwan-Hwa; Fountzilas, George; Bourhis, Jean; Pignon, Jean Pierre
2017-01-01
Purpose The role of adjuvant chemotherapy (AC) or induction chemotherapy (IC) in the treatment of locally advanced nasopharyngeal carcinoma is controversial. The individual patient data from the Meta-Analysis of Chemotherapy in Nasopharynx Carcinoma database were used to compare all available treatments. Methods All randomized trials of radiotherapy (RT) with or without chemotherapy in nonmetastatic nasopharyngeal carcinoma were considered. Overall, 20 trials and 5,144 patients were included. Treatments were grouped into seven categories: RT alone (RT), IC followed by RT (IC-RT), RT followed by AC (RT-AC), IC followed by RT followed by AC (IC-RT-AC), concomitant chemoradiotherapy (CRT), IC followed by CRT (IC-CRT), and CRT followed by AC (CRT-AC). P-score was used to rank the treatments. Fixed- and random-effects frequentist network meta-analysis models were applied. Results The three treatments with the highest probability of benefit on overall survival (OS) were CRT-AC, followed by CRT and IC-CRT, with respective hazard ratios (HRs [95% CIs]) compared with RT alone of 0.65 (0.56 to 0.75), 0.77 (0.64 to 0.92), and 0.81 (0.63 to 1.04). HRs (95% CIs) of CRT-AC compared with CRT for OS, progression-free survival (PFS), locoregional control, and distant control (DC) were, respectively, 0.85 (0.68 to 1.05), 0.81 (0.66 to 0.98), 0.70 (0.48 to 1.02), and 0.87 (0.61 to 1.25). IC-CRT ranked second for PFS and the best for DC. CRT never ranked first. HRs of CRT compared with IC-CRT for OS, PFS, locoregional control, and DC were, respectively, 0.95 (0.72 to 1.25), 1.13 (0.88 to 1.46), 1.05 (0.70 to 1.59), and 1.55 (0.94 to 2.56). Regimens with more chemotherapy were associated with increased risk of acute toxicity. Conclusion The addition of AC to CRT achieved the highest survival benefit and consistent improvement for all end points. The addition of IC to CRT achieved the highest effect on DC. PMID:27918720
36th International Symposium on Combustion (ISOC2016)
2016-12-01
GREENHOUSE GASES / IC ENGINE COMBUSTION I GAS TURBINE COMBUSTION I NOVEL COMBUSTION CONCEPTS, TECHNOLOGIES AND SYSTEMS 15. SUBJECT TERMS Reaction...pollutants and greenhouse gases; IC engine combustion; Gas turbine combustion; Novel combustion concepts, technologies and systems 16. SECURITY...PLENARY LECTURE TRANSFER (15 min) am Turbulent Flames IC Engines Laminar Flames Reaction Kinetics Gas Turbines Soot Solid Fuels/Pollutants
Raveis, Victoria H; Conway, Laurie J; Uchida, Mayuko; Pogorzelska-Maziarz, Monika; Larson, Elaine L; Stone, Patricia W
2014-04-01
Health-care-associated infections (HAIs) remain a major patient safety problem even as policy and programmatic efforts designed to reduce HAIs have increased. Although information on implementing effective infection control (IC) efforts has steadily grown, knowledge gaps remain regarding the organizational elements that improve bedside practice and accommodate variations in clinical care settings. We conducted in-depth, semistructured interviews in 11 hospitals across the United States with a range of hospital personnel involved in IC (n = 116). We examined the collective nature of IC and the organizational elements that can enable disparate groups to work together to prevent HAIs. Our content analysis of participants' narratives yielded a rich description of the organizational process of implementing adherence to IC. Findings document the dynamic, fluid, interactional, and reactive nature of this process. Three themes emerged: implementing adherence efforts institution-wide, promoting an institutional culture to sustain adherence, and contending with opposition to the IC mandate.
Initiative in Concurrent Engineering (DICE). Phase 1.
1990-02-09
and power of commercial and military electronics systems. The continual evolution of HDE technology offers far greater flexibility in circuit design... powerful magnetic field of the permanent magnets in the sawyer motors. This makes it possible to have multiple robots in the workcell and to have them...Controller. The Adept IC was chosen because of its extensive processing power , integrated grayscale vision, standard 28 industrial I/O control
Design of remote control alarm system by microwave detection
NASA Astrophysics Data System (ADS)
Wang, Junli
2018-04-01
A microwave detection remote control alarm system is designed, which is composed of a Microwave detectors, a radio receiving/transmitting module and a digital encoding/decoding IC. When some objects move into the surveillance area, microwave detectors will generate a control signal to start transmitting system. A radio control signal will be spread by the transmitting module, once the signal can be received, and it will be disposed by some circuits, arousing some voices that awake the watching people. The whole device is a modular configuration, it not only has some advantage of frequency stable, but also reliable and adjustment-free, and it is suitable for many kinds of demands within the distance of 100m.
Costs of interstitial cystitis in a managed care population.
Clemens, J Quentin; Meenan, Richard T; Rosetti, Maureen C O'Keeffe; Kimes, Terry; Calhoun, Elizabeth A
2008-05-01
To assess the direct medical costs, medication, and procedure use associated with interstitial cystitis (IC) in women in the Kaiser Permanente Northwest (KPNW) managed care population. The KPNW electronic medical record was used to identify women diagnosed with IC (n = 239). Each of these patients was matched with three controls according to age and duration in the health plan. Health plan cost accounting data were used to determine the inpatient, outpatient, and pharmacy costs for 1998 to 2003. An analysis of the prescription medication use and cystoscopic and urodynamic procedures commonly associated with IC was also performed. To evaluate for co-morbidities, an automated risk-adjustment model linked to 28 chronic medical conditions was applied to the administrative data sets from both groups. The mean duration from the date of IC diagnosis to the end of the study period was 36.6 months (range 1.4 to 60). The mean yearly costs were 2.4-fold greater for the patients than for the controls ($7100 versus $2994), and the median yearly costs were 3.8-fold greater ($5000 versus $1304). These cost differences were predominantly due to outpatient and pharmacy expenses. Medication and procedure use were significantly greater for the patients than for the controls. These findings were consistent across risk-adjustment model categories, which suggest that the observed cost differences are IC specific. The direct per-person costs of IC are high, with average yearly costs approximately $4000 greater than for the age-matched controls. This cost differential is an underestimate, because the costs preceding the diagnosis, the use of alternative therapies, indirect costs, and the costs of those with IC that is not diagnosed were not included.
NASA Astrophysics Data System (ADS)
Jarboe, N.; Minnett, R.; Koppers, A.; Constable, C.; Tauxe, L.; Jonestrask, L.
2017-12-01
The Magnetics Information Consortium (MagIC) supports an online database for the paleo, geo, and rock magnetic communities ( https://earthref.org/MagIC ). Researchers can upload data into the archive and download data as selected with a sophisticated search system. MagIC has completed the transition from an Oracle backed, Perl based, server oriented website to an ElasticSearch backed, Meteor based thick client website technology stack. Using JavaScript on both the sever and the client enables increased code reuse and allows easy offloading many computational operations to the client for faster response. On-the-fly data validation, column header suggestion, and spreadsheet online editing are some new features available with the new system. The 3.0 data model, method codes, and vocabulary lists can be browsed via the MagIC website and more easily updated. Source code for MagIC is publicly available on GitHub ( https://github.com/earthref/MagIC ). The MagIC file format is natively compatible with the PmagPy ( https://github.com/PmagPy/PmagPy) paleomagnetic analysis software. MagIC files can now be downloaded from the database and viewed and interpreted in the PmagPy GUI based tool, pmag_gui. Changes or interpretations of the data can then be saved by pmag_gui in the MagIC 3.0 data format and easily uploaded to the MagIC database. The rate of new contributions to the database has been increasing with many labs contributing measurement level data for the first time in the last year. Over a dozen file format conversion scripts are available for translating non-MagIC measurement data files into the MagIC format for easy uploading. We will continue to work with more labs until the whole community has a manageable workflow for contributing their measurement level data. MagIC will continue to provide a global repository for archiving and retrieving paleomagnetic and rock magnetic data and, with the new system in place, be able to more quickly respond to the community's requests for changes and improvements.
ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.
Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu
2015-02-01
IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.
Center, S A; Warner, K L; Randolph, J F; Wakshlag, J J; Sunvold, G D
2011-01-01
Resting energy expenditure (REE) approximates ≥60% of daily energy expenditure (DEE). Accurate REE determination could facilitate sequential comparisons among patients and diseases if normalized against lean body mass (LBM). (1) Validate open-flow indirect calorimetry (IC) system and multifrequency bioelectrical impedance analysis (MF-BIA) to determine REE and LBM, respectively, in healthy nonsedated cats of varied body conditions; (2) normalize REE against LBM. Fifty-seven adult neutered domestic short-haired cats with stable BW. Continuous (45-min) IC-measurements determined least observed metabolism REE. Cage gas flow regulated with mass flow controllers was verified using nitrogen dilution; span gases calibrated gas measurements. Respiratory quotient accuracy was verified using alcohol combustion. IC-REE was compared to DEE, determined using doubly labeled water. MF-BIA LBM was validated against criterion references (deuterium, sodium bromide). Intra- and interassay variation was determined for IC and MF-BIA. Mean IC-REE (175 ± 38.7 kcal; 1.5-14% intra- and interassay CV%) represented 61 ± 14.3% of DEE. Best MF-BIA measurements were collected in sternal recumbency and with electrodes in neck-tail configuration. MF-BIA LBM was not significantly different from criterion references and generated LBM interassay CV% of 6.6-10.1%. Over- and underconditioned cats had significantly (P ≤ .05) lower and higher IC-REE (kcal/kg) respectively, compared with normal-conditioned cats. However, differences resolved with REE/LBM (approximating 53 ± 10.3 kcal/LBM [kg]). IC and MF-BIA validated herein reasonably estimate REE and LBM in cats. REE/LBM(kg) may permit comparison of energy utilization in sequential studies or among different cats. Copyright © 2011 by the American College of Veterinary Internal Medicine.
Byrd, Amy L.; Loeber, Rolf; Pardini, Dustin A.
2013-01-01
Background While associations between conduct disorder (CD), oppositional defiant disorder (ODD), attention deficit hyperactivity disorder (ADHD), and interpersonal callousness (IC) symptoms and delinquency onset are well established, less is known about whether these characteristics differentiate desisting and persisting delinquency. The current study examined whether childhood and adolescent CD, ODD, ADHD, and IC symptoms uniquely distinguished boys who exhibited persisting versus desisting delinquency from adolescence into adulthood. Methods Participants were 503 boys (57% African American) repeatedly assessed from ages 7 to 25. Associations between childhood and adolescent CD, ODD, ADHD, and IC symptoms and desisting and persisting delinquency were examined independently and after controlling for their co-occurrence and multiple covariates. Results Conduct disorder and IC symptoms in childhood and adolescence were higher among boys whose delinquency persisted into adulthood relative to those boys whose delinquency desisted across time. After controlling for the overlap between symptoms of ADHD, ODD, CD and IC, only adolescent CD and IC symptoms emerged as unique predictors of the differentiation between persisters and desisters. Moreover, adolescent CD and IC symptoms continued to contribute unique variance even after childhood levels of these characteristics were accounted for. Conclusions Boys with elevated levels of CD and IC symptoms in childhood and adolescence are at risk for exhibiting a pattern of delinquency that persists from adolescence into adulthood. Intervention efforts designed to prevent chronic delinquency should target youth with co-occurring CD and IC symptoms in childhood and adolescence. PMID:22176342
NASA Astrophysics Data System (ADS)
Miwa, Shotaro; Kage, Hiroshi; Hirai, Takashi; Sumi, Kazuhiko
We propose a probabilistic face recognition algorithm for Access Control System(ACS)s. Comparing with existing ACSs using low cost IC-cards, face recognition has advantages in usability and security that it doesn't require people to hold cards over scanners and doesn't accept imposters with authorized cards. Therefore face recognition attracts more interests in security markets than IC-cards. But in security markets where low cost ACSs exist, price competition is important, and there is a limitation on the quality of available cameras and image control. Therefore ACSs using face recognition are required to handle much lower quality images, such as defocused and poor gain-controlled images than high security systems, such as immigration control. To tackle with such image quality problems we developed a face recognition algorithm based on a probabilistic model which combines a variety of image-difference features trained by Real AdaBoost with their prior probability distributions. It enables to evaluate and utilize only reliable features among trained ones during each authentication, and achieve high recognition performance rates. The field evaluation using a pseudo Access Control System installed in our office shows that the proposed system achieves a constant high recognition performance rate independent on face image qualities, that is about four times lower EER (Equal Error Rate) under a variety of image conditions than one without any prior probability distributions. On the other hand using image difference features without any prior probabilities are sensitive to image qualities. We also evaluated PCA, and it has worse, but constant performance rates because of its general optimization on overall data. Comparing with PCA, Real AdaBoost without any prior distribution performs twice better under good image conditions, but degrades to a performance as good as PCA under poor image conditions.
Reusable experiment controllers, case studies
NASA Astrophysics Data System (ADS)
Buckley, Brian A.; Gaasbeck, Jim Van
1996-03-01
Congress has given NASA and the science community a reality check. The tight and ever shrinking budgets are trimming the fat from many space science programs. No longer can a Principal Investigator (PI) afford to waste development dollars on re-inventing spacecraft controllers, experiment/payload controllers, ground control systems, or test sets. Inheritance of the Ground Support Equipment (GSE) from one program to another is not a significant re-use of technology to develop a science mission in these times. Reduction of operational staff and highly autonomous experiments are needed to reduce the sustaining cost of a mission. The re-use of an infrastructure from one program to another is needed to truly attain the cost and time savings required. Interface and Control Systems, Inc. (ICS) has a long history of re-usable software. Navy, Air Force, and NASA programs have benefited from the re-use of a common control system from program to program. Several standardization efforts in the AIAA have adopted the Spacecraft Command Language (SCL) architecture as a point solution to satisfy requirements for re-use and autonomy. The Environmental Research Institute of Michigan (ERIM) has been a long-standing customer of ICS and are working on their 4th generation system using SCL. Much of the hardware and software infrastructure has been re-used from mission to mission with little cost for re-hosting a new experiment. The same software infrastructure has successfully been used on Clementine, and an end-to-end system is being deployed for the Far Ultraviolet Spectroscopic Explorer (FUSE) for Johns Hopkins University. A case study of the ERIM programs, Clementine and FUSE will be detailed in this paper.
A digital intensity stabilization system for HeNe laser
NASA Astrophysics Data System (ADS)
Wei, Zhimeng; Lu, Guangfeng; Yang, Kaiyong; Long, Xingwu; Huang, Yun
2012-02-01
A digital intensity stabilization system for HeNe laser is developed. Based on a switching power IC to design laser power supply and a general purpose microcontroller to realize digital PID control, the system constructs a closed loop to stabilize the laser intensity by regulating its discharge current. The laser tube is made of glass ceramics and its integrated structure is steady enough to eliminate intensity fluctuations at high frequency and attenuates all intensity fluctuations, and this makes it easy to tune the control loop. The control loop between discharge current and photodiode voltage eliminates the long-term drifts. The intensity stability of the HeNe laser with this system is 0.014% over 12 h.
Resource Allocation and Cross Layer Control in Wireless Networks
2006-08-25
arrival rates lies within the capacity region of the network. The notion of controlling the system to maximize its stability region and the following...optimization problem (4.5) that must be solved at the beginning of 48 Dynamic Control for Network Stability each time slot requires in general knowledge...Dynamic Control for Network Stability ~ (c) ab (t) those of any other feasible algorithm, then for any time t 0; X ic U (c) i (t) "X b ~ (c) ab (t) X
Digital Platform for Wafer-Level MEMS Testing and Characterization Using Electrical Response
Brito, Nuno; Ferreira, Carlos; Alves, Filipe; Cabral, Jorge; Gaspar, João; Monteiro, João; Rocha, Luís
2016-01-01
The uniqueness of microelectromechanical system (MEMS) devices, with their multiphysics characteristics, presents some limitations to the borrowed test methods from traditional integrated circuits (IC) manufacturing. Although some improvements have been performed, this specific area still lags behind when compared to the design and manufacturing competencies developed over the last decades by the IC industry. A complete digital solution for fast testing and characterization of inertial sensors with built-in actuation mechanisms is presented in this paper, with a fast, full-wafer test as a leading ambition. The full electrical approach and flexibility of modern hardware design technologies allow a fast adaptation for other physical domains with minimum effort. The digital system encloses a processor and the tailored signal acquisition, processing, control, and actuation hardware control modules, capable of the structure position and response analysis when subjected to controlled actuation signals in real time. The hardware performance, together with the simplicity of the sequential programming on a processor, results in a flexible and powerful tool to evaluate the newest and fastest control algorithms. The system enables measurement of resonant frequency (Fr), quality factor (Q), and pull-in voltage (Vpi) within 1.5 s with repeatability better than 5 ppt (parts per thousand). A full-wafer with 420 devices under test (DUTs) has been evaluated detecting the faulty devices and providing important design specification feedback to the designers. PMID:27657087
Digital Platform for Wafer-Level MEMS Testing and Characterization Using Electrical Response.
Brito, Nuno; Ferreira, Carlos; Alves, Filipe; Cabral, Jorge; Gaspar, João; Monteiro, João; Rocha, Luís
2016-09-21
The uniqueness of microelectromechanical system (MEMS) devices, with their multiphysics characteristics, presents some limitations to the borrowed test methods from traditional integrated circuits (IC) manufacturing. Although some improvements have been performed, this specific area still lags behind when compared to the design and manufacturing competencies developed over the last decades by the IC industry. A complete digital solution for fast testing and characterization of inertial sensors with built-in actuation mechanisms is presented in this paper, with a fast, full-wafer test as a leading ambition. The full electrical approach and flexibility of modern hardware design technologies allow a fast adaptation for other physical domains with minimum effort. The digital system encloses a processor and the tailored signal acquisition, processing, control, and actuation hardware control modules, capable of the structure position and response analysis when subjected to controlled actuation signals in real time. The hardware performance, together with the simplicity of the sequential programming on a processor, results in a flexible and powerful tool to evaluate the newest and fastest control algorithms. The system enables measurement of resonant frequency (Fr), quality factor (Q), and pull-in voltage (Vpi) within 1.5 s with repeatability better than 5 ppt (parts per thousand). A full-wafer with 420 devices under test (DUTs) has been evaluated detecting the faulty devices and providing important design specification feedback to the designers.
A Simple Data Logging System for Ballistic Applications
2006-07-01
6. AUTHOR(S) Thomas Kottke 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Research Laboratory ATTN...AMSRD-ARL-WM-TE Aberdeen Proving Ground, MD 21005-5066 8. PERFORMING ORGANIZATION REPORT NUMBER ARL-TR-3853 10. SPONSOR/MONITOR’S ACRONYM(S...IC2 PIC18F458-I/L-ND $185.50/25 IC SOCKET PLCC 44POS SMT for IC2 ED80010-ND $15.05/10 IC SRAM 512KX8 LP WIDE 32- SOIC IC1 and IC4 428-1075-ND $118.00
On the thermodynamics of waste heat recovery from internal combustion engine exhaust gas
NASA Astrophysics Data System (ADS)
Meisner, G. P.
2013-03-01
The ideal internal combustion (IC) engine (Otto Cycle) efficiency ηIC = 1-(1/r)(γ - 1) is only a function of engine compression ratio r =Vmax/Vmin and exhaust gas specific heat ratio γ = cP/cV. Typically r = 8, γ = 1.4, and ηIC = 56%. Unlike the Carnot Cycle where ηCarnot = 1-(TC/TH) for a heat engine operating between hot and cold heat reservoirs at TH and TC, respectively, ηIC is not a function of the exhaust gas temperature. Instead, the exhaust gas temperature depends only on the intake gas temperature (ambient), r, γ, cV, and the combustion energy. The ejected exhaust gas heat is thermally decoupled from the IC engine and conveyed via the exhaust system (manifold, pipe, muffler, etc.) to ambient, and the exhaust system is simply a heat engine that does no useful work. The maximum fraction of fuel energy that can be extracted from the exhaust gas stream as useful work is (1-ηIC) × ηCarnot = 32% for TH = 850 K (exhaust) and TC = 370 K (coolant). This waste heat can be recovered using a heat engine such as a thermoelectric generator (TEG) with ηTEG> 0 in the exhaust system. A combined IC engine and TEG system can generate net useful work from the exhaust gas waste heat with efficiency ηWH = (1-ηIC) × ηCarnot ×ηTEG , and this will increase the overall fuel efficiency of the total system. Recent improvements in TEGs yield ηTEG values approaching 15% giving a potential total waste heat conversion efficiency of ηWH = 4.6%, which translates into a fuel economy improvement approaching 5%. This work is supported by the US DOE under DE-EE0005432.
30 CFR 57.22102 - Smoking (I-C mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Smoking (I-C mines). 57.22102 Section 57.22102... Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22102 Smoking (I-C mines). (a) Persons shall not smoke or carry smoking materials, matches, or lighters underground or within 50 feet of...
30 CFR 57.22102 - Smoking (I-C mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Smoking (I-C mines). 57.22102 Section 57.22102... Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22102 Smoking (I-C mines). (a) Persons shall not smoke or carry smoking materials, matches, or lighters underground or within 50 feet of...
30 CFR 57.22102 - Smoking (I-C mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Smoking (I-C mines). 57.22102 Section 57.22102... Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22102 Smoking (I-C mines). (a) Persons shall not smoke or carry smoking materials, matches, or lighters underground or within 50 feet of...
30 CFR 57.22102 - Smoking (I-C mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Smoking (I-C mines). 57.22102 Section 57.22102... Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22102 Smoking (I-C mines). (a) Persons shall not smoke or carry smoking materials, matches, or lighters underground or within 50 feet of...
Ruesch, Rodney; Jenkins, Philip N.; Ma, Nan
2004-03-09
There is disclosed apparatus and apparatus for impedance control to provide for controlling the impedance of a communication circuit using an all-digital impedance control circuit wherein one or more control bits are used to tune the output impedance. In one example embodiment, the impedance control circuit is fabricated using circuit components found in a standard macro library of a computer aided design system. According to another example embodiment, there is provided a control for an output driver on an integrated circuit ("IC") device to provide for forming a resistor divider network with the output driver and a resistor off the IC device so that the divider network produces an output voltage, comparing the output voltage of the divider network with a reference voltage, and adjusting the output impedance of the output driver to attempt to match the output voltage of the divider network and the reference voltage. Also disclosed is over-sampling the divider network voltage, storing the results of the over sampling, repeating the over-sampling and storing, averaging the results of multiple over sampling operations, controlling the impedance with a plurality of bits forming a word, and updating the value of the word by only one least significant bit at a time.
The Chiasmus of Design: Paradoxical Outcomes in the e-Government Reform of UK Children's Services
NASA Astrophysics Data System (ADS)
Wastell, David; White, Sue; Broadhurst, Karen
This paper describes a detailed ethnographic study of the design problems of a major national IT system in the UK- The Integrated Children’s System (ICS). The implementation of the ICS has disrupted social work practice and engendered growing professional resistance, prompting a fundamental review of its design. Marshall McLuhan’s concept of chiasmus is a central feature of our analysis of the vicissitudes of ICS. Chiasmus refers to the tendency of any system, when pushed too far, to produce unintended contradictory effects, and is an intrinsic feature of the behaviour of complex, socio-technical systems. The dysfunctions of the ICS provide a pertinent, large-scale example. The ICS constitutes an attempt, via technological means, to re-organize child welfare services in the UK. Whilst aimed at improving child safety, the ICS has had the opposite effect of increasing the potential for error. This chiasmus has been exposed through the multi-site ethnography reported here, which shows how rigidly designed processes, enforced by IT systems, force social work professionals into unsafe investigative and recording practices which increase the risk of errors. The paper ends by proposing an alternative approach to design, based on socio-technical precepts, emphasizing the principles of minimum critical specification, user-centeredness and local autonomy.
Bentz, Joe; O’Connor, Michael P.; Bednarczyk, Dallas; Coleman, JoAnn; Lee, Caroline; Palm, Johan; Pak, Y. Anne; Perloff, Elke S.; Reyner, Eric; Balimane, Praveen; Brännström, Marie; Chu, Xiaoyan; Funk, Christoph; Guo, Ailan; Hanna, Imad; Herédi-Szabó, Krisztina; Hillgren, Kate; Li, Libin; Hollnack-Pusch, Evelyn; Jamei, Masoud; Lin, Xuena; Mason, Andrew K.; Neuhoff, Sibylle; Patel, Aarti; Podila, Lalitha; Plise, Emile; Rajaraman, Ganesh; Salphati, Laurent; Sands, Eric; Taub, Mitchell E.; Taur, Jan-Shiang; Weitz, Dietmar; Wortelboer, Heleen M.; Xia, Cindy Q.; Xiao, Guangqing; Yabut, Jocelyn; Yamagata, Tetsuo; Zhang, Lei
2013-01-01
A P-glycoprotein (P-gp) IC50 working group was established with 23 participating pharmaceutical and contract research laboratories and one academic institution to assess interlaboratory variability in P-gp IC50 determinations. Each laboratory followed its in-house protocol to determine in vitro IC50 values for 16 inhibitors using four different test systems: human colon adenocarcinoma cells (Caco-2; eleven laboratories), Madin-Darby canine kidney cells transfected with MDR1 cDNA (MDCKII-MDR1; six laboratories), and Lilly Laboratories Cells—Porcine Kidney Nr. 1 cells transfected with MDR1 cDNA (LLC-PK1-MDR1; four laboratories), and membrane vesicles containing human P-glycoprotein (P-gp; five laboratories). For cell models, various equations to calculate remaining transport activity (e.g., efflux ratio, unidirectional flux, net-secretory-flux) were also evaluated. The difference in IC50 values for each of the inhibitors across all test systems and equations ranged from a minimum of 20- and 24-fold between lowest and highest IC50 values for sertraline and isradipine, to a maximum of 407- and 796-fold for telmisartan and verapamil, respectively. For telmisartan and verapamil, variability was greatly influenced by data from one laboratory in each case. Excluding these two data sets brings the range in IC50 values for telmisartan and verapamil down to 69- and 159-fold. The efflux ratio-based equation generally resulted in severalfold lower IC50 values compared with unidirectional or net-secretory-flux equations. Statistical analysis indicated that variability in IC50 values was mainly due to interlaboratory variability, rather than an implicit systematic difference between test systems. Potential reasons for variability are discussed and the simplest, most robust experimental design for P-gp IC50 determination proposed. The impact of these findings on drug-drug interaction risk assessment is discussed in the companion article (Ellens et al., 2013) and recommendations are provided. PMID:23620485
Challenges in integrating multidisciplinary data into a single e-infrastructure
NASA Astrophysics Data System (ADS)
Atakan, Kuvvet; Jeffery, Keith G.; Bailo, Daniele; Harrison, Matthew
2015-04-01
The European Plate Observing System (EPOS) aims to create a pan-European infrastructure for solid Earth science to support a safe and sustainable society. The mission of EPOS is to monitor and understand the dynamic and complex Earth system by relying on new e-science opportunities and integrating diverse and advanced Research Infrastructures in Europe for solid Earth Science. EPOS will enable innovative multidisciplinary research for a better understanding of the Earth's physical and chemical processes that control earthquakes, volcanic eruptions, ground instability and tsunami as well as the processes driving tectonics and Earth's surface dynamics. EPOS will improve our ability to better manage the use of the subsurface of the Earth. Through integration of data, models and facilities EPOS will allow the Earth Science community to make a step change in developing new concepts and tools for key answers to scientific and socio-economic questions concerning geo-hazards and geo-resources as well as Earth sciences applications to the environment and to human welfare. EPOS is now getting into its Implementation Phase (EPOS-IP). One of the main challenges during the implementation phase is the integration of multidisciplinary data into a single e-infrastructure. Multidisciplinary data are organized and governed by the Thematic Core Services (TCS) and are driven by various scientific communities encompassing a wide spectrum of Earth science disciplines. TCS data, data products and services will be integrated into a platform "the ICS system" that will ensure their interoperability and access to these services by the scientific community as well as other users within the society. This requires dedicated tasks for interactions with the various TCS-WPs, as well as the various distributed ICS (ICS-Ds), such as High Performance Computing (HPC) facilities, large scale data storage facilities, complex processing and visualization tools etc. Computational Earth Science (CES) services are identified as a transversal activity and as such need to be harmonized and provided within the ICS. In order to develop a metadata catalogue and the ICS system, the content from the entire spectrum of services included in TCS, ICS-Ds as well as CES activities, need to be organized in a systematic manner taking into account global and European IT-standards, while complying with the user needs and data provider requirements.
Automated Visibility & Cloud Cover Measurements with a Solid State Imaging System
1989-03-01
GL-TR-89-0061 SIO Ref. 89-7 MPL-U-26/89 AUTOMATED VISIBILITY & CLOUD COVER MEASUREMENTS WITH A SOLID-STATE IMAGING SYSTEM C) to N4 R. W. Johnson W. S...include Security Classification) Automated Visibility & Cloud Measurements With A Solid State Imaging System 12. PERSONAL AUTHOR(S) Richard W. Johnson...based imaging systems , their ics and control algorithms, thus they ar.L discussed sepa- initial deployment and the preliminary application of rately
The effect of domain-general inhibition-related training on language switching: An ERP study.
Liu, Huanhuan; Liang, Lijuan; Dunlap, Susan; Fan, Ning; Chen, Baoguo
2016-01-01
Previous studies have demonstrated that inhibitory control ability could be improved by training, and the Inhibitory Control (IC) Model implies that enhanced domain-general inhibition may elicit certain changes in language switch costs. In the present study, we aimed to examine the effects of domain-general inhibition training on performance in a language switching task, including which phase of domain-general inhibitory control benefits from training during an overt picture naming task in L1 and L2, using the event-related brain potentials (ERPs). Results showed that the language switch costs of bilinguals with high inhibitory control (high-IC) were symmetrical in both pretest and posttest, and those of bilinguals with low inhibitory control (low-IC) were asymmetrical in the pretest, but symmetrical in the posttest. Moreover, the high-IC group showed a larger LPC (late positive component) for L2 switch trials than for L1 trials in both pretest and posttest. In contrast, the low-IC group only exhibited a similar pattern of LPC in the posttest, but not in the pretest. These results indicate that inhibition training could increase the efficiency of language switching, and inhibitory control may play a key role during the lexical selection response phase. Overall, the present study is the first one to provide electrophysiological evidence for individual differences in the domain-general inhibition impact on language switching performance in low-proficient bilinguals. Copyright © 2015 Elsevier B.V. All rights reserved.
Mutale, Wilbroad; Stringer, Jeffrey; Chintu, Namwinga; Chilengi, Roma; Mwanamwenge, Margaret Tembo; Kasese, Nkatya; Balabanova, Dina; Spicer, Neil; Lewis, James; Ayles, Helen
2014-01-01
Introduction In many low income countries, the delivery of quality health services is hampered by health system-wide barriers which are often interlinked, however empirical evidence on how to assess the level and scope of these barriers is scarce. A balanced scorecard is a tool that allows for wider analysis of domains that are deemed important in achieving the overall vision of the health system. We present the quantitative results of the 12 months follow-up study applying the balanced scorecard approach in the BHOMA intervention with the aim of demonstrating the utility of the balanced scorecard in evaluating multiple building blocks in a trial setting. Methods The BHOMA is a cluster randomised trial that aims to strengthen the health system in three rural districts in Zambia. The intervention aims to improve clinical care quality by implementing practical tools that establish clear clinical care standards through intensive clinic implementations. This paper reports the findings of the follow-up health facility survey that was conducted after 12 months of intervention implementation. Comparisons were made between those facilities in the intervention and control sites. STATA version 12 was used for analysis. Results The study found significant mean differences between intervention(I) and control (C) sites in the following domains: Training domain (Mean I:C; 87.5.vs 61.1, mean difference 23.3, p = 0.031), adult clinical observation domain (mean I:C; 73.3 vs.58.0, mean difference 10.9, p = 0.02 ) and health information domain (mean I:C; 63.6 vs.56.1, mean difference 6.8, p = 0.01. There was no gender differences in adult service satisfaction. Governance and motivation scores did not differ between control and intervention sites. Conclusion This study demonstrates the utility of the balanced scorecard in assessing multiple elements of the health system. Using system wide approaches and triangulating data collection methods seems to be key to successful evaluation of such complex health intervention. Trial number ClinicalTrials.gov NCT01942278 PMID:24751780
Mutale, Wilbroad; Stringer, Jeffrey; Chintu, Namwinga; Chilengi, Roma; Mwanamwenge, Margaret Tembo; Kasese, Nkatya; Balabanova, Dina; Spicer, Neil; Lewis, James; Ayles, Helen
2014-01-01
In many low income countries, the delivery of quality health services is hampered by health system-wide barriers which are often interlinked, however empirical evidence on how to assess the level and scope of these barriers is scarce. A balanced scorecard is a tool that allows for wider analysis of domains that are deemed important in achieving the overall vision of the health system. We present the quantitative results of the 12 months follow-up study applying the balanced scorecard approach in the BHOMA intervention with the aim of demonstrating the utility of the balanced scorecard in evaluating multiple building blocks in a trial setting. The BHOMA is a cluster randomised trial that aims to strengthen the health system in three rural districts in Zambia. The intervention aims to improve clinical care quality by implementing practical tools that establish clear clinical care standards through intensive clinic implementations. This paper reports the findings of the follow-up health facility survey that was conducted after 12 months of intervention implementation. Comparisons were made between those facilities in the intervention and control sites. STATA version 12 was used for analysis. The study found significant mean differences between intervention(I) and control (C) sites in the following domains: Training domain (Mean I:C; 87.5.vs 61.1, mean difference 23.3, p = 0.031), adult clinical observation domain (mean I:C; 73.3 vs.58.0, mean difference 10.9, p = 0.02 ) and health information domain (mean I:C; 63.6 vs.56.1, mean difference 6.8, p = 0.01. There was no gender differences in adult service satisfaction. Governance and motivation scores did not differ between control and intervention sites. This study demonstrates the utility of the balanced scorecard in assessing multiple elements of the health system. Using system wide approaches and triangulating data collection methods seems to be key to successful evaluation of such complex health intervention. ClinicalTrials.gov NCT01942278.
Plant hormones including ethylene are recruited in calyx inflation in Solanaceous plants.
Khan, Muhammad Ramzan; Hu, Jinyong; He, Chaoying
2012-07-01
Plant hormones direct many processes of floral and post-floral morphogenesis in Angiosperms. However, their role in shaping floral morphological novelties, such as inflated calyx syndrome (ICS) exhibited by a few genera of the Solanaceae, remains unknown. In Withania and Physalis, sepals resume growth after pollination and encapsulate the mature fruit to form a balloon-like structure, i.e. ICS. The epidermal cells of calyx show enlargement and lobation post-fertilization. Application of hormones to depistillated flower buds of Withania revealed that cytokinins and gibberellins mimic fertilization signals. The ICS development is a synchronous step with fruit development; both processes are under the control of more or less the same set of hormones, including cytokinins and gibberellic acids. Interestingly, inhibition of ethylene in the system is sufficient to yield inflated calyx in Withania. In contrast, Tubocapsicum, a closely related species and an evolutionary natural loss mutant of ICS - showed no response to applied hormones, and ethylene led to inflation of the receptacle indirectly. In addition to hormones, the expression of an MPF2-like MADS-box transcription factor in sepals is essential for ICS formation. Nevertheless, the interactions between MPF2-like genes and hormones are barely detectable at the transcript level. Our data provide insight into the role of hormones in generating floral morphological diversity during evolution. Copyright © 2012 Elsevier GmbH. All rights reserved.
Kido, Jun-Ichi; Murakami, Shinya; Kitamura, Masahiro; Yanagita, Manabu; Tabeta, Koichi; Yamazaki, Kazuhisa; Yoshie, Hiromasa; Watanabe, Hisashi; Izumi, Yuichi; Suda, Reiko; Yamamoto, Matsuo; Shiba, Hideki; Fujita, Tsuyoshi; Kurihara, Hidemi; Mizuno, Mitsuharu; Mishima, Akihiro; Kawahara, Nobumasa; Hashimoto, Kazuhiro; Naruishi, Koji; Nagata, Toshihiko
2017-09-06
Calprotectin, an inflammation-related protein, is present in gingival crevicular fluid (GCF) and the determination of calprotectin is useful for diagnosing periodontal diseases. We have recently developed a novel immunochromatographic (IC) chip system (SI-101402) to determine calprotectin levels in GCF. In the present study, the usefulness of this diagnostic system was investigated in patients with periodontal diseases. Thirty-six patients with periodontal diseases participated in this clinical test at multiple centers. Periodontitis sites (n=118) and non-periodontitis (healthy) sites (n=120) were selected after periodontal examination. GCF collection and periodontal examination were performed at baseline, after supragingival and subgingival scaling and root planing. Calprotectin amount in GCF was determined using a novel IC chip system and evaluated as a visual score and an IC reader value. The correlation between GCF calprotectin levels, clinical indicators and changes in calprotectin levels by periodontal treatments were investigated. Receiver operating characteristic (ROC) analysis of IC reader value for GCF calprotectin was performed to predict periodontal diseases. The visual score of GCF calprotectin was highly correlated the IC reader value. IC reader values of GCF calprotectin in periodontitis group were higher than those of healthy group at three dental examination stages and they significantly decreased with periodontal treatments. Visual scores and IC reader values of GCF calprotectin were correlated to the levels of clinical indicators. ROC analysis for GCF calprotectin showed an optimal cutoff value to predict periodontal diseases. Determination of GCF calprotectin using a novel IC chip system is useful for diagnosis of periodontal diseases.
Intratumoral immunocytokine treatment results in enhanced antitumor effects.
Johnson, Erik E; Lum, Hillary D; Rakhmilevich, Alexander L; Schmidt, Brian E; Furlong, Meghan; Buhtoiarov, Ilia N; Hank, Jacquelyn A; Raubitschek, Andrew; Colcher, David; Reisfeld, Ralph A; Gillies, Stephen D; Sondel, Paul M
2008-12-01
Immunocytokines (IC), consisting of tumor-specific monoclonal antibodies fused to the immunostimulatory cytokine interleukin 2 (IL2), exert significant antitumor effects in several murine tumor models. We investigated whether intratumoral (IT) administration of IC provided enhanced antitumor effects against subcutaneous tumors. Three unique ICs (huKS-IL2, hu14.18-IL2, and GcT84.66-IL2) were administered systemically or IT to evaluate their antitumor effects against tumors expressing the appropriate IC-targeted tumor antigens. The effect of IT injection of the primary tumor on a distant tumor was also evaluated. Here, we show that IT injection of IC resulted in enhanced antitumor effects against B16-KSA melanoma, NXS2 neuroblastoma, and human M21 melanoma xenografts when compared to intravenous (IV) IC injection. Resolution of both primary and distant subcutaneous tumors and a tumor-specific memory response were demonstrated following IT treatment in immunocompetent mice bearing NXS2 tumors. The IT effect of huKS-IL2 IC was antigen-specific, enhanced compared to IL2 alone, and dose-dependent. Hu14.18-IL2 also showed greater IT effects than IL2 alone. The antitumor effect of IT IC did not always require T cells since IT IC induced antitumor effects against tumors in both SCID and nude mice. Localization studies using radiolabeled (111)In-GcT84.66-IL2 IC confirmed that IT injection resulted in a higher concentration of IC at the tumor site than IV administration. In conclusion, we suggest that IT IC is more effective than IV administration against palpable tumors. Further testing is required to determine how to potentially incorporate IT administration of IC into an antitumor regimen that optimizes local and systemic anticancer therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Kedar G.; Pannu, Satinderpall S.
An integrated circuit system having an integrated circuit (IC) component which is able to have its functionality destroyed upon receiving a command signal. The system may involve a substrate with the IC component being supported on the substrate. A module may be disposed in proximity to the IC component. The module may have a cavity and a dissolving compound in a solid form disposed in the cavity. A heater component may be configured to heat the dissolving compound to a point of sublimation where the dissolving compound changes from a solid to a gaseous dissolving compound. A triggering mechanism maymore » be used for initiating a dissolution process whereby the gaseous dissolving compound is allowed to attack the IC component and destroy a functionality of the IC component.« less
Tong, Ming; Leão, Raiane; Vimbela, Gina V; Yalcin, Emine B; Kay, Jared; Krotow, Alexander; de la Monte, Suzanne M
2017-07-01
White matter is an early and important yet under-evaluated target of Alzheimer's disease (AD). Metabolic impairments due to insulin and insulin-like growth factor resistance contribute to white matter degeneration because corresponding signal transduction pathways maintain oligodendrocyte function and survival. This study utilized a model of sporadic AD in which adult Long Evans rats administered intracerebral streptozotocin (i.c. STZ) developed AD-type neurodegeneration. Temporal lobe white matter lipid ion profiles were characterized by matrix-assisted laser desorption/ionization-imaging mass spectrometry (MALDI-IMS). Although the lipid ion species expressed in the i.c. STZ and control groups were virtually identical, i.c. STZ mainly altered the abundances of various lipid ions. Correspondingly, the i.c. STZ group was distinguished from control by principal component analysis and data bar plots. i.c. STZ mainly reduced expression of lipid ions with low m/z's (less than 810) as well as the upper range m/z lipids (m/z 964-986), and increased expression of lipid ions with m/z's between 888 and 937. Phospholipids were mainly included among the clusters inhibited by i.c. STZ, while both sulfatides and phospholipids were increased by i.c. STZ. However, Chi-Square analysis demonstrated significant i.c. STZ-induced trend reductions in phospholipids and increases in sulfatides (P<0.00001). The i.c. STZ model of sporadic AD is associated with broad and sustained abnormalities in temporal lobe white matter lipids. The findings suggest that the i.c. STZ model could be used for pre-clinical studies to assess therapeutic measures for their ability to restore white matter integrity in AD. Copyright © 2017 Elsevier Inc. All rights reserved.
Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors
Goodrich, LF; Cheggour, N; Stauffer, TC; Filla, BJ; Lu, XF
2013-01-01
We review variable-temperature, transport critical-current (Ic) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable-temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or Ic liq) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb3Sn, and MgB2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the Ic liq. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases. PMID:26401435
Saito, N; Kamata, A; Itoga, M; Tamaki, M; Kayaba, H; Ritz, T
2017-04-01
Inhaled corticosteroids (ICS) and inhaled corticosteroids combined with long-acting beta2-agonist (ICS/LABA) are standard treatments for asthma. However, factors that might help reduce medication in well-controlled asthma are unknown. We classified problems of asthma patients into biological, psychological and adherence factors, and investigated factors associated with the indication and failure of a medication step-down treatment. Two hundred twenty two well-controlled asthma patients receiving ICS or ICS/LABA were assessed for physical and psychiatric problems and followed up for one year from adjustment of their treatment step. Factor B was defined as a presence of chronic upper airway complications. Factor P was defined as presence of psychiatric complications such as sleep disorder, depression, anxiety and somatoform disorders. Factor A was defined as poor adherence to ICS or ICS/LABA inhaler of 75% or less. Success in step-down treatment was defined as maintenance of well-controlled status for over one year after step-down. Factor B was the most important single negative predictive factor for indication for step-down treatment (Odds ratio; 0.19). Factor A increased the risk of failure to maintain step-down treatment most significantly by 23-fold, and factor B increased it by 11-fold. The combination of factors B and A increased failure by 24-fold, factors P and A by 21-fold, all three factors by 36-fold. Factor P only interacted with the other factors to reduce chances of stepping down, but did not constitute a problem factor when present alone. The evaluation of biological, psychological and adherence problems may lead to a more proactive and targeted approach to step-down treatment for patients with well-controlled asthma. © 2017 John Wiley & Sons Ltd.
Rabinovitz, Shiri; Kaufman, Yotam; Ludwig, Guy; Razin, Aharon; Shemer, Ruth
2012-01-01
The Prader-Willi syndrome/Angelman syndrome (PWS/AS) imprinted domain is regulated by a bipartite imprinting control center (IC) composed of a sequence around the SNRPN promoter (PWS-IC) and a 880-bp sequence located 35 kb upstream (AS-IC). The AS-IC imprint is established during gametogenesis and confers repression upon PWS-IC on the maternal allele. Mutation at PWS-IC on the paternal allele leads to gene silencing across the entire PWS/AS domain. This silencing implies that PWS-IC functions on the paternal allele as a bidirectional activator. Here we examine the mechanism by which PWS-IC activates the paternally expressed genes (PEGs) using transgenes that include the PWS-IC sequence in the presence or absence of AS-IC and NDN, an upstream PEG, as an experimental model. We demonstrate that PWS-IC is in fact an activator of NDN. This activation requires an unmethylated PWS-IC in the gametes and during early embryogenesis. PWS-IC is dispensable later in development. Interestingly, a similar activation of a nonimprinted gene (APOA1) was observed, implying that PWS-IC is a universal activator. To decipher the mechanism by which PWS-IC confers activation of remote genes, we performed methylated DNA immunoprecipitation (MeDIP) array analysis on lymphoblast cell lines that revealed dispersed, rather than continued differential methylation. However, chromatin conformation capture (3c) experiments revealed a physical interaction between PWS-IC and the PEGs, suggesting that activation of PEGs may require their proximity to PWS-IC. PMID:22529396
Modularized construction of general integrated circuits on individual carbon nanotubes.
Pei, Tian; Zhang, Panpan; Zhang, Zhiyong; Qiu, Chenguang; Liang, Shibo; Yang, Yingjun; Wang, Sheng; Peng, Lian-Mao
2014-06-11
While constructing general integrated circuits (ICs) with field-effect transistors (FETs) built on individual CNTs is among few viable ways to build ICs with small dimension and high performance that can be compared with that of state-of-the-art Si based ICs, this has not been demonstrated owing to the absence of valid and well-tolerant fabrication method. Here we demonstrate a modularized method for constructing general ICs on individual CNTs with different electric properties. A pass-transistor-logic style 8-transistor (8-T) unit is built, demonstrated as a multifunctional function generator with good tolerance to inhomogeneity in the CNTs used and used as a building block for constructing general ICs. As an example, an 8-bits BUS system that is widely used to transfer data between different systems in a computer is constructed. This is the most complicated IC fabricated on individual CNTs to date, containing 46 FETs built on six individual semiconducting CNTs. The 8-T unit provides a good basis for constructing complex ICs to explore the potential and limits of CNT ICs given the current imperfection in available CNT materials and may also be developed into a universal and efficient way for constructing general ICs on ideal CNT materials in the future.
Schweizer, Tina H; Olino, Thomas M; Dyson, Margaret W; Laptook, Rebecca S; Klein, Daniel N
2017-09-08
Rumination, a thinking style characterized by a repetitive inward focus on negative cognitions, has been linked to internalizing disorders, particularly depression. Moreover, research suggests that rumination may be a cognitive vulnerability that predisposes individuals to psychopathology. Surprisingly little is known, however, about the etiology and development of rumination. The present study examined the role of specific components of child temperamental negative emotionality (sadness, fear, anger) and effortful control (inhibition), as well as parenting behaviors during early childhood on the development of rumination in middle childhood. Early childhood (age 3) temperament and parenting behaviors were assessed observationally and rumination was self-reported in middle childhood (age 9) in a large community sample (N = 425; 47.1% female). Two significant interactions emerged. First, temperamental anger interacted with inhibitory control (IC) such that high anger and low IC predicted higher levels of rumination, whereas low anger and low IC predicted lower levels of rumination. Second, IC interacted with parenting such that children with low IC and positive parenting had lower levels of rumination. In contrast, children with high IC reported similar levels of rumination regardless of parenting quality. Overall, these findings highlight the interplay of early IC with temperamental anger and positive parenting in the development of ruminative tendencies in middle childhood.
Lanzarin, Morgan; Parizoto, Patricia; Santos, Gilmar M.
2016-01-01
BACKGROUND: Intermittent claudication (IC) is a debilitating condition that mostly affects elderly people. IC is manifested by a decrease in ambulatory function. Individuals with IC present with motor and sensory nerve dysfunction in the lower extremities, which may lead to deficits in balance. OBJECTIVE: This study aimed to measure postural control and isokinetic muscle function in individuals with intermittent claudication. METHOD: The study included 32 participants of both genders, 16 IC participants (mean age: 64 years, SD=6) and 16 healthy controls (mean age: 67 years, SD=5), which were allocated into two groups: intermittent claudication group (ICG) and control group (CG). Postural control was assessed using the displacement and velocity of the center of pressure (COP) during the sensory organization test (SOT) and the motor control test (MCT). Muscle function of the flexor and extensor muscles of the knee and ankle was measured by an isokinetic dynamometer. Independent t tests were used to calculate the between-group differences. RESULTS: The ICG presented greater displacement (p =0.027) and speed (p =0.033) of the COP in the anteroposterior direction (COPap) during the MCT, as well as longer latency (p =0.004). There were no between-group differences during the SOT. The ICG showed decreased muscle strength and power in the plantar flexors compared to the CG. CONCLUSION: Subjects with IC have lower values of strength and muscle power of plantiflexores, as well as changes in postural control in dynamic conditions. These individuals may be more vulnerable to falls than healthy subjects. PMID:26786077
Lee, Dohwan; Kim, Yong Tae; Lee, Jee Won; Kim, Do Hyun; Seo, Tae Seok
2016-05-15
We have developed an integrated direct loop-mediated isothermal amplification (Direct LAMP) microdevice incorporated with an immunochromatographic strip (ICS) to identify bacteria contaminated in real samples. The Direct LAMP is a novel isothermal DNA amplification technique which does not require thermal cycling steps as well as any sample preparation steps such as cell lysis and DNA extraction for amplifying specific target genes. In addition, the resultant amplicons were colorimetrically detected on the ICS, thereby enabling the entire genetic analysis process to be simplified. The two functional units (Direct LAMP and ICS) were integrated on a single device without use of the tedious and complicated microvalve and tubing systems. The utilization of a slidable plate allows us to manipulate the fluidic control in the microchannels manually and the sequential operation of the Direct LAMP and ICS detection could be performed by switching the slidable plate to each functional unit. Thus, the combination of the direct isothermal amplification without any sample preparation and thermal cycling steps, the ICS based amplicon detection by naked eyes, and the slidable plate to eliminate the microvalves in the integrated microdevice would be an ideal platform for point-of-care DNA diaganotics. On the integrated Direct LAMP-ICS microdevice, we could analyze Staphylococcus aureus (S. aureus) and Escherichia coli O157:H7 (E. coli O157:H7) contaminated in human whole blood or milk at a single-cell level within 1h. Copyright © 2015 Elsevier B.V. All rights reserved.
Vasbinder, Erwin; Dahhan, Nordin; Wolf, Bart; Zoer, Jan; Blankman, Ellen; Bosman, Diederik; van Dijk, Liset; van den Bemt, Patricia
2013-03-01
To investigate the association of ethnicity with objectively, electronically measured adherence to inhaled corticosteroids (ICS) in a multicultural population of children with asthma in the city of Amsterdam. The study was designed as a prospective, observational multicenter study in which adherence to ICS and potential risk factors for adherence to ICS were measured in a cohort of Moroccan and native Dutch children with asthma. Electronic adherence measurements were performed for 3 months per patient using a Real Time Medication Monitoring (RTMM) system. Ethnicity and other potential risk factors, such as socio-economic status, asthma control and parental medication beliefs, were extracted from medical records or parent interviews. The association between adherence and ethnicity was analysed using multivariate linear regression analysis. A total of 90 children (aged 1-11 years) were included in the study and data of 87 children were used for analysis. Average adherence to ICS was 49.3 %. Native Dutch children showed higher adherence to ICS than Moroccan children (55.9 vs. 42.5 %, respectively; p = 0.044, univariate analysis). After correction for confounders (>3 annual visits to the paediatric outpatient clinic, regular use of a spacer during inhalation), the final regression model showed that ethnicity was independently associated with adherence (p = 0.028). In our Western European population of inner city children with asthma, poor adherence to ICS was a serious problem, and even somewhat more so in ethnic minorities. Paediatricians involved in asthma treatment should be aware of these cultural differences in medication-taking behaviour, but further studies are needed to elucidate the causal mechanism.
San Román, B; Garrido, V; Sánchez, S; Martínez-Ballesteros, I; Garaizar, J; Mainar-Jaime, R C; Migura-Garcia, L; Grilló, M J
2018-04-27
Salmonella is a major foodborne pathogen causing important zoonosis worldwide. Pigs asymptomatically infected in mesenteric lymph nodes (MLN) can be intermittent shedders of the pathogen through faeces, being considered a major source of human infections. European baseline studies of fattening pig salmonellosis are based on Salmonella detection in MLN. This work studies the relationship between Salmonella infection in MLN and intestinal content (IC) shedding at slaughter and the relationship between the presence of the pathogen and the serologic status at farm level. Mean Salmonella prevalence in the selected pigs (vertically integrated production system of Navarra, Spain) was 7.2% in MLN, 8.4% in IC and 9.6% in serum samples. In this low-moderate prevalence context, poor concordance was found between MLN infection and shedding at slaughter and between bacteriology and serology. In fact, most of shedders were found uninfected in MLN (83%) or carrying different Salmonella strains in MLN and in IC (90%). The most prevalent Salmonellae were Typhimurium resistant to ACSSuT ± Nx or ASSuT antibiotic families, more frequently found invading the MLN (70%) than in IC (33.9%). Multivariable analysis revealed that risk factors associated with the presence of Salmonella in MLN or in IC were different, mainly related either to good hygiene practices or to water and feed control, respectively. Overall, in this prevalence context, detection of Salmonella in MLN is an unreliable predictor of faecal shedding at abattoir, indicating that subclinical infections in fattening pigs MLN could have limited relevance in the IC shedding. © 2018 Blackwell Verlag GmbH.
30 CFR 57.22104 - Open flames (I-C mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Open flames (I-C mines). 57.22104 Section 57... Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22104 Open flames (I-C mines). (a) Open flames, including cutting and welding, shall not be used underground. (b) Welding and...
30 CFR 57.22104 - Open flames (I-C mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Open flames (I-C mines). 57.22104 Section 57... Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22104 Open flames (I-C mines). (a) Open flames, including cutting and welding, shall not be used underground. (b) Welding and...
30 CFR 57.22104 - Open flames (I-C mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Open flames (I-C mines). 57.22104 Section 57... Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22104 Open flames (I-C mines). (a) Open flames, including cutting and welding, shall not be used underground. (b) Welding and...
30 CFR 57.22104 - Open flames (I-C mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Open flames (I-C mines). 57.22104 Section 57... Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22104 Open flames (I-C mines). (a) Open flames, including cutting and welding, shall not be used underground. (b) Welding and...
Byrd, Amy L; Loeber, Rolf; Pardini, Dustin A
2012-04-01
While associations between conduct disorder (CD), oppositional defiant disorder (ODD), attention deficit hyperactivity disorder (ADHD), and interpersonal callousness (IC) symptoms and delinquency onset are well established, less is known about whether these characteristics differentiate desisting and persisting delinquency. The current study examined whether childhood and adolescent CD, ODD, ADHD, and IC symptoms uniquely distinguished boys who exhibited persisting versus desisting delinquency from adolescence into adulthood. Participants were 503 boys (57% African American) repeatedly assessed from ages 7 to 25. Associations between childhood and adolescent CD, ODD, ADHD, and IC symptoms and desisting and persisting delinquency were examined independently and after controlling for their co-occurrence and multiple covariates. Conduct disorder and IC symptoms in childhood and adolescence were higher among boys whose delinquency persisted into adulthood relative to those boys whose delinquency desisted across time. After controlling for the overlap between symptoms of ADHD, ODD, CD and IC, only adolescent CD and IC symptoms emerged as unique predictors of the differentiation between persisters and desisters. Moreover, adolescent CD and IC symptoms continued to contribute unique variance even after childhood levels of these characteristics were accounted for. Boys with elevated levels of CD and IC symptoms in childhood and adolescence are at risk for exhibiting a pattern of delinquency that persists from adolescence into adulthood. Intervention efforts designed to prevent chronic delinquency should target youth with co-occurring CD and IC symptoms in childhood and adolescence. © 2011 The Authors. Journal of Child Psychology and Psychiatry © 2011 Association for Child and Adolescent Mental Health.
DiSantostefano, Rachael L.; Sampson, Tim; Le, Hoa Van; Hinds, David; Davis, Kourtney J.; Bakerly, Nawar Diar
2014-01-01
Introduction Observational studies using case-control designs have showed an increased risk of pneumonia associated with inhaled corticosteroid (ICS)-containing medications in patients with chronic obstructive pulmonary disease (COPD). New-user observational cohort designs may minimize biases associated with previous case-control designs. Objective To estimate the association between ICS and pneumonia among new users of ICS relative to inhaled long-acting bronchodilator (LABD) monotherapy. Methods Pneumonia events in COPD patients ≥45 years old were compared among new users of ICS medications (n = 11,555; ICS, ICS/long-acting β2-agonist [LABA] combination) and inhaled LABD monotherapies (n = 6,492; LABA, long-acting muscarinic antagonists) using Cox proportional hazards models, with propensity scores to adjust for confounding. Setting: United Kingdom electronic medical records with linked hospitalization and mortality data (2002–2010). New users were censored at earliest of: pneumonia event, death, changing/discontinuing treatment, or end of follow-up. Outcomes: severe pneumonia (primary) and any pneumonia (secondary). Results Following adjustment, new use of ICS-containing medications was associated with an increased risk of pneumonia hospitalization (n = 322 events; HR = 1.55, 95% CI: 1.14, 2.10) and any pneumonia (n = 702 events; HR = 1.49, 95% CI: 1.22, 1.83). Crude incidence rates of any pneumonia were 48.7 and 30.9 per 1000 person years among the ICS-containing and LABD cohorts, respectively. Excess risk of pneumonia with ICS was reduced when requiring ≥1 month or ≥ 6 months of new use. There was an apparent dose-related effect, with greater risk at higher daily doses of ICS. There was evidence of channeling bias, with more severe patients prescribed ICS, for which the analysis may not have completely adjusted. Conclusions The results of this new-user cohort study are consistent with published findings; ICS were associated with a 20–50% increased risk of pneumonia in COPD, which reduced with exposure time. This risk must be weighed against the benefits when prescribing ICS to patients with COPD. PMID:24878543
COSTS OF INTERSTITAL CYSTITIS IN A MANAGED CARE POPULATION
Clemens, J. Quentin; Meenan, Richard T.; O’Keeffe Rosetti, Maureen C.; Kimes, Terry; Calhoun, Elizabeth A.
2008-01-01
Objective This study assessed the direct medical costs, medication and procedure use associated with interstitial cystitis (IC) in women in the Kaiser Permanente Northwest (KPNW) managed care population. Methods The KPNW electronic medical record was utilized to identify women diagnosed with interstitial cystitis (n=239). Each of these cases was matched with three controls based on age and duration in the health plan. Health plan cost accounting data were used to determine inpatient, outpatient, and pharmacy costs for 1998-2003. An analysis of prescription medication use, cystoscopic and urodynamic procedures commonly associated with IC was also performed. To evaluate for comorbidities, an automated risk-adjustment model (RxRisk) linked to 28 chronic medical conditions was applied to the administrative datasets from both groups. Results The mean duration from the date of IC diagnosis to the end of the study period was 36.6 months (range 1.4-60). Mean yearly costs were 2.4-fold greater in cases than controls ($7100 vs. $2994), and median yearly costs were 3.8-fold greater ($5000 vs. $1304). These cost differences were predominantly due to outpatient and pharmacy expenses. Medication and procedure use were significantly greater in cases than controls. These findings were consistent across RxRisk categories, which suggest that the observed cost differences are IC-specific. Conclusions The direct per-person costs of IC are high, with average yearly costs approximately $4000 greater than age-matched controls. This cost differential is an underestimate, as costs preceding the diagnosis, use of alternative therapies, indirect costs and costs of those with IC that is not diagnosed are not included. PMID:18329077
Engineering information on an Analog Signal to Discrete Time Interval Converter (ASDT-IC)
NASA Technical Reports Server (NTRS)
Schwarz, F. C.
1974-01-01
An electronic control system for nondissipative dc power converters is presented which improves (1) the routinely attainable static output voltage accuracy to the order of + or - 1% for ambient temperatures from -55 to 100 C and (2) the dynamic stability by utilizing approximately one tenth of the feedback gain needed otherwise. Performance is due to a functional philosophy of deterministic pulse modulation based on pulse area control and to an autocompensated signal processing principle. The system can be implemented with commercially available unselected components.
A multi-channel instrumentation system for biosignal recording.
Yu, Hong; Li, Pengfei; Xiao, Zhiming; Peng, Chung-Ching; Bashirullah, Rizwan
2008-01-01
This paper reports a highly integrated battery operated multi-channel instrumentation system intended for physiological signal recording. The mixed signal IC has been fabricated in standard 0.5microm 5V 3M-2P CMOS process and features 32 instrumentation amplifiers, four 8b SAR ADCs, a wireless power interface with Li-ion battery charger, low power bidirectional telemetry and FSM controller with power gating control for improved energy efficiency. The chip measures 3.2mm by 4.8mm and dissipates approximately 2.1mW when fully operational.
Summary of Research, Academic Departments, 1983-1984.
1984-10-01
miagnetoelast ic strain gauiges. hydraulic (ollrols svsteiiis, robotics, aiiol gas tul-ili( engine (lilic(’. Th’lis wear, e’Ii phasis has beent placed...gatige, the( gifligV id~ itsSsigiifI Co(lifltioflihlg. High Level Real-Time Software for Hydraulic Control Systems in Deep Submergence Vehicles h~iSiAt...Simulation of a Hydraulic Control System At )VISUMt: ASSOCIATII PiiOtISSOt1 IAIU IIB V. I I)L SKA\\ Theo Jriluialrv pourpose of’ this l’C51’drch is to) wxIihi
Dynamical Competition of IC-Industry Clustering from Taiwan to China
NASA Astrophysics Data System (ADS)
Tsai, Bi-Huei; Tsai, Kuo-Hui
2009-08-01
Most studies employ qualitative approach to explore the industrial clusters; however, few research has objectively quantified the evolutions of industry clustering. The purpose of this paper is to quantitatively analyze clustering among IC design, IC manufacturing as well as IC packaging and testing industries by using the foreign direct investment (FDI) data. The Lotka-Volterra system equations are first adopted here to capture the competition or cooperation among such three industries, thus explaining their clustering inclinations. The results indicate that the evolution of FDI into China for IC design industry significantly inspire the subsequent FDI of IC manufacturing as well as IC packaging and testing industries. Since IC design industry lie in the upstream stage of IC production, the middle-stream IC manufacturing and downstream IC packing and testing enterprises tend to cluster together with IC design firms, in order to sustain a steady business. Finally, Taiwan IC industry's FDI amount into China is predicted to cumulatively increase, which supports the industrial clustering tendency for Taiwan IC industry. Particularly, the FDI prediction of Lotka-Volterra model performs superior to that of the conventional Bass model after the forecast accuracy of these two models are compared. The prediction ability is dramatically improved as the industrial mutualism among each IC production stage is taken into account.
Alternative Force Structuring Strategies for Military Satellite Communication Systems
1987-12-01
IC= -4 41 fu~- I C = C= C = Ac -- .G.. LILA ILIJ * 36 The following equation expresses how dBm power levels were calculated (33:120-121): dBm = 10...and Arms Control. Cambridge, Massachusetts: Abt Books, 1982. 16. Heffes, Harry and Anurag Kumar. "Stochastic Damage Models and Dependence Effects in
Laforest, L; Van Ganse, É; Devouassoux, G; Chatté, G; Tamberou, C; Belhassen, M; Chamba, G
2015-01-01
Adherence to inhaled corticosteroids (ICS) remains a major issue for asthma management, even among patients receiving a regular prescription from their doctor. The frequency of deliberate interruption of ICS, and of spontaneous changes of dose, were studied in a population of asthma patients recruited in community pharmacies. Asthma patients (aged 18-50) recruited in community pharmacies reported in self-administered questionnaires their spontaneous interruptions and changes of doses of ICS during the past 3 months. The characteristics of patients who interrupted their therapy or who modified the dose were compared with other patients. The studied population included 252 patients (mean age 35 year-old, females: 59%), of whom 62% had inadequately controlled asthma. Among these patients, 25% had interrupted ICS therapy during the past 3 months, while 21% spontaneously changed the dose. The most reported reason for interrupting ICS was the cessation of symptoms (50%). In multivariate analysis, interrupting ICS was mainly associated with inadequate asthma control (OR=3.1, 95% CI 1.5-6.4), while the strongest association with changing ICS doses was the patients' perception of asthma as a concern in their lives (OR=3.2, 95% CI 1.2-8.4). These results underline a poor understanding of the purpose of ICS therapy by patients. They also highlight the need of therapeutic education to improve the management of the disease. Copyright © 2014 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Linzarini, Adriano; Dollfus, Sonia; Etard, Olivier; Orliac, François; Houdé, Olivier
2018-01-01
Abstract Inhibitory control (IC) is a core executive function that enables humans to resist habits, temptations, or distractions. IC efficiency in childhood is a strong predictor of academic and professional success later in life. Based on analysis of the sulcal pattern, a qualitative feature of cortex anatomy determined during fetal life and stable during development, we searched for evidence that interindividual differences in IC partly trace back to prenatal processes. Using anatomical magnetic resonance imaging (MRI), we analyzed the sulcal pattern of two key regions of the IC neural network, the dorsal anterior cingulate cortex (ACC) and the inferior frontal cortex (IFC), which limits the inferior frontal gyrus. We found that the sulcal pattern asymmetry of both the ACC and IFC contributes to IC (Stroop score) in children and adults: participants with asymmetrical ACC or IFC sulcal patterns had better IC efficiency than participants with symmetrical ACC or IFC sulcal patterns. Such additive effects of IFC and ACC sulcal patterns on IC efficiency suggest that distinct early neurodevelopmental mechanisms targeting different brain regions likely contribute to IC efficiency. This view shares some analogies with the “common variant–small effect” model in genetics, which states that frequent genetic polymorphisms have small effects but collectively account for a large portion of the variance. Similarly, each sulcal polymorphism has a small but additive effect: IFC and ACC sulcal patterns, respectively, explained 3% and 14% of the variance of the Stroop interference scores. PMID:29527565
Tissier, Cloélia; Linzarini, Adriano; Allaire-Duquette, Geneviève; Mevel, Katell; Poirel, Nicolas; Dollfus, Sonia; Etard, Olivier; Orliac, François; Peyrin, Carole; Charron, Sylvain; Raznahan, Armin; Houdé, Olivier; Borst, Grégoire; Cachia, Arnaud
2018-01-01
Inhibitory control (IC) is a core executive function that enables humans to resist habits, temptations, or distractions. IC efficiency in childhood is a strong predictor of academic and professional success later in life. Based on analysis of the sulcal pattern, a qualitative feature of cortex anatomy determined during fetal life and stable during development, we searched for evidence that interindividual differences in IC partly trace back to prenatal processes. Using anatomical magnetic resonance imaging (MRI), we analyzed the sulcal pattern of two key regions of the IC neural network, the dorsal anterior cingulate cortex (ACC) and the inferior frontal cortex (IFC), which limits the inferior frontal gyrus. We found that the sulcal pattern asymmetry of both the ACC and IFC contributes to IC (Stroop score) in children and adults: participants with asymmetrical ACC or IFC sulcal patterns had better IC efficiency than participants with symmetrical ACC or IFC sulcal patterns. Such additive effects of IFC and ACC sulcal patterns on IC efficiency suggest that distinct early neurodevelopmental mechanisms targeting different brain regions likely contribute to IC efficiency. This view shares some analogies with the "common variant-small effect" model in genetics, which states that frequent genetic polymorphisms have small effects but collectively account for a large portion of the variance. Similarly, each sulcal polymorphism has a small but additive effect: IFC and ACC sulcal patterns, respectively, explained 3% and 14% of the variance of the Stroop interference scores.
Multi-Objective Online Initialization of Spacecraft Formations
NASA Technical Reports Server (NTRS)
Jeffrey, Matthew; Breger, Louis; How, Jonathan P.
2007-01-01
This paper extends a previously developed method for finding spacecraft initial conditions (ICs) that minimize the drift resulting from J2 disturbances while also minimizing the fuel required to attain those ICs. It generalizes the single spacecraft optimization to a formation-wide optimization valid for an arbitrary number of vehicles. Additionally, the desired locations of the spacecraft, separate from the starting location, can be specified, either with respect to a reference orbit, or relative to the other spacecraft in the formation. The three objectives (minimize drift, minimize fuel, and maintain a geometric template) are expressed as competing costs in a linear optimization, and are traded against one another through the use of scalar weights. By carefully selecting these weights and re-initializing the formation at regular intervals, a closed-loop, formation-wide control system is created. This control system can be used to reconfigure the formations on the fly, and creates fuel-efficient plans by placing the spacecraft in semi-invariant orbits. The overall approach is demonstrated through nonlinear simulations for two formations a GEO orbit, and an elliptical orbit.
Analysis of the Space Shuttle main engine simulation
NASA Technical Reports Server (NTRS)
Deabreu-Garcia, J. Alex; Welch, John T.
1993-01-01
This is a final report on an analysis of the Space Shuttle Main Engine Program, a digital simulator code written in Fortran. The research was undertaken in ultimate support of future design studies of a shuttle life-extending Intelligent Control System (ICS). These studies are to be conducted by NASA Lewis Space Research Center. The primary purpose of the analysis was to define the means to achieve a faster running simulation, and to determine if additional hardware would be necessary for speeding up simulations for the ICS project. In particular, the analysis was to consider the use of custom integrators based on the Matrix Stability Region Placement (MSRP) method. In addition to speed of execution, other qualities of the software were to be examined. Among these are the accuracy of computations, the useability of the simulation system, and the maintainability of the program and data files. Accuracy involves control of truncation error of the methods, and roundoff error induced by floating point operations. It also involves the requirement that the user be fully aware of the model that the simulator is implementing.
The Genetic Etiology of Inhibitory Control and Behavior Problems at 24 Months of Age
ERIC Educational Resources Information Center
Gagne, Jeffrey R.; Saudino, Kimberly J.; Asherson, Philip
2011-01-01
Background: To investigate links between inhibitory control (IC) and behavior problems in early childhood, as well as genetic and environmental covariances between these two constructs. Methods: Parent and laboratory ratings of IC and parent ratings of externalizing and attention deficit hyperactivity disorder behaviors were administered at 24…
Inhibitory Control in Childhood Stuttering
ERIC Educational Resources Information Center
Eggers, Kurt; De Nil, Luc F.; Van den Bergh, Bea R. H.
2013-01-01
Purpose: The purpose of this study was to investigate whether previously reported parental questionnaire-based differences in inhibitory control (IC; Eggers, De Nil, & Van den Bergh, 2010) would be supported by direct measurement of IC using a computer task. Method: Participants were 30 children who stutter (CWS; mean age = 7;05 years) and 30…
Nonlinear system analysis in bipolar integrated circuits
NASA Astrophysics Data System (ADS)
Fang, T. F.; Whalen, J. J.
1980-01-01
Since analog bipolar integrated circuits (IC's) have become important components in modern communication systems, the study of the Radio Frequency Interference (RFI) effects in bipolar IC amplifiers is an important subject for electromagnetic compatibility (EMC) engineering. The investigation has focused on using the nonlinear circuit analysis program (NCAP) to predict RF demodulation effects in broadband bipolar IC amplifiers. The audio frequency (AF) voltage at the IC amplifier output terminal caused by an amplitude modulated (AM) RF signal at the IC amplifier input terminal was calculated and compared to measured values. Two broadband IC amplifiers were investigated: (1) a cascode circuit using a CA3026 dual differential pair; (2) a unity gain voltage follower circuit using a micro A741 operational amplifier (op amp). Before using NCAP for RFI analysis, the model parameters for each bipolar junction transistor (BJT) in the integrated circuit were determined. Probe measurement techniques, manufacturer's data, and other researcher's data were used to obtain the required NCAP BJT model parameter values. An important contribution included in this effort is a complete set of NCAP BJT model parameters for most of the transistor types used in linear IC's.
Brandariz-Nuñez, Alberto; Otero-Romero, Iria; Benavente, Javier; Martinez-Costas, Jose M
2011-09-20
We have recently developed a versatile tagging system (IC-tagging) that causes relocation of the tagged proteins to ARV muNS-derived intracellular globular inclusions. In the present study we demonstrate (i) that the IC-tag can be successfully fused either to the amino or carboxyl terminus of the protein to be tagged and (ii) that IC-tagged proteins are able to interact between them and perform complex reactions that require such interactions while integrated into muNS inclusions, increasing the versatility of the IC-tagging system. Also, our studies with the DsRed protein add some light on the structure/function relationship of the evolution of DsRed chromophore. Copyright © 2011 Elsevier B.V. All rights reserved.
The purpose of this memorandum is to ensure that EPA Regions scrutinize all proposed plans, draft and final RODs, and post-ROD documents that address institutional controls (ICs) in order to verify that they adequately document the objectives of the ICs and clearly identify who has responsibility for implementation, monitoring, reporting, and enforcement of the IC.
Rosendahl, Mikkel; Mosgaard, Berit Jul; Høgdall, Claus
2016-10-01
To determine if survival in stage I ovarian cancer is influenced by cyst emptying, lymph node resection and chemotherapy. A survival analysis of 607 patients with ovarian cancer in stage IA, IA with cyst emptying (IAempty) and IC1 was performed. There was no difference in five-year survival between IA (87%) and IC1 (87%) (p=0.899), between IA and IAempty (86%) (p=0.500) nor between IA+IAempty (87%) and IC1 without IAempty (84%) (p=0.527). Five-year survival rate (5YSR) was significantly higher after lymph node resection in stage IA (94% vs. 85%; p=0.01) and IA+IC1 (93% vs. 85%; p=0.004). In multivariate analysis, lymph node resection improved prognosis significantly for all sub-stages, whereas stage and chemotherapy did not affect survival. In stage IA ovarian cancer, controlled cyst emptying without spill does not worsen prognosis. Lymph node resection is associated with improved survival in stage IA and IC1. Chemotherapy should only be offered where randomized controlled studies have shown a benefit. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Parsons, C Lowell; Zupkas, Paul; Proctor, Jeffrey; Koziol, James; Franklin, Amie; Giesing, Dennis; Davis, Edward; Lakin, Charles M; Kahn, Bruce S; Garner, William J
2012-01-01
It has been reported in an open-label study that the combination of alkalinized lidocaine and heparin can immediately relieve the symptoms of urinary urgency, frequency, and pain associated with interstitial cystitis (IC). This combination has also been reported to relieve pain associated with sex in patients with IC. The aim of this study was to corroborate these findings in a multicenter setting. The study design was a multicenter prospective, double-blind, crossover, placebo-controlled trial. Each participant met all of the clinical National Institute of Diabetes and Digestive and Kidney Diseases criteria (excluding cystoscopy) for IC. Each patient received drug and control, in random order, within 48 hours of enrolling in the study. The primary outcome measure was percent change in pain score (11-point analog pain scale) 12 hours after receiving the drug or control. Secondary measures were the global assessment response (GAR) of symptoms and 12-hour average urgency reduction determined from 11-point urgency scales. Eighteen (18) patients completed the trial. The average reduction of pain over 12 hours was 21% for control and 42% for active drug (P = 0.0363). GAR was 13% for control and 50% for drug (P = 0.0137). Average urgency reduction was 13% for control and 35% for drug (P = 0.0328). The combination of alkalinized lidocaine and heparin provides up to 12 hours of relief from urgency and pain associated with IC. This combination provides significant immediate relief of symptoms for patients with IC. © 2011 International Society for Sexual Medicine.
An integrated control and readout circuit for implantable multi-target electrochemical biosensing.
Ghoreishizadeh, Sara S; Baj-Rossi, Camilla; Cavallini, Andrea; Carrara, Sandro; De Micheli, Giovanni
2014-12-01
We describe an integrated biosensor capable of sensing multiple molecular targets using both cyclic voltammetry (CV) and chronoamperometry (CA). In particular, we present our custom IC to realize voltage control and current readout of the biosensors. A mixed-signal circuit block generates sub-Hertz triangular waveform for the biosensors by means of a direct-digital-synthesizer to control CV. A current to pulse-width converter is realized to output the data for CA measurement. The IC is fabricated in 0.18 μm technology. It consumes 220 μW from 1.8 V supply voltage, making it suitable for remotely-powered applications. Electrical measurements show excellent linearity in sub- μA current range. Electrochemical measurements including CA measurements of glucose and lactate and CV measurements of the anti-cancer drug Etoposide have been acquired with the fabricated IC and compared with a commercial equipment. The results obtained with the fabricated IC are in good agreement with those of the commercial equipment for both CV and CA measurements.
Shinozaki, Sachiyo; Saito, Motoaki; Kawatani, Masahito
2005-02-01
Prostaglandins (PGs) are well known as one of the chemical mediators of inflammation. Nonsteroidal anti-inflammatory drugs (NSAIDs), PG synthesis inhibitors, are used for anti-nociception and/or anti-inflammation. We examine the effect of loxoprofen, an NSAID, on micturiton in acetic acid-induced bladder inflammation of the rats. In cystometrogram study with saline infusion into the urinary bladder, loxoprofen did not alter the interval of bladder contraction (IC, 107% of the control). IC was shortened by acetic acid infusion (65% of the control) and loxoprofen prolonged the IC (162% of acetic acid infused period). This prolonged IC was approximately same as the control. Loxoprofen did not alter the threshold pressure and the maximal voiding pressure. These data suggest that PGE2 might not play a part of normal micturition and may play a part of the micturition reflex during acetic acid infusion. That is, loxoprofen might be useful for pathological hyperreflex of the micturition.
Reynolds, Penny S; Michael, Mary J; Spiess, Bruce D
2017-02-09
Clinical trial success depends on appropriate management, but practical guidance to trial organisation and planning is lacking. The Incident Command System (ICS) is the 'gold standard' management system developed for managing diverse operations in major incident and public health arenas. It enables effective and flexible management through integration of personnel, procedures, resources, and communications within a common hierarchical organisational structure. Conventional ICS organisation consists of five function modules: Command, Planning, Operations, Logistics, and Finance/Administration. Large clinical trials will require a separate Regulatory Administrative arm, and an Information arm, consisting of dedicated data management and information technology staff. We applied ICS principles to organisation and management of the Prehospital Use of Plasma in Traumatic Haemorrhage (PUPTH) trial. This trial was a multidepartmental, multiagency, randomised clinical trial investigating prehospital administration of thawed plasma on mortality and coagulation response in severely injured trauma patients. We describe the ICS system as it would apply to large clinical trials in general, and the benefits, barriers, and lessons learned in utilising ICS principles to reorganise and coordinate the PUPTH trial. Without a formal trial management structure, early stages of the trial were characterised by inertia and organisational confusion. Implementing ICS improved organisation, coordination, and communication between multiple agencies and service groups, and greatly streamlined regulatory compliance administration. However, unfamiliarity of clinicians with ICS culture, conflicting resource allocation priorities, and communication bottlenecks were significant barriers. ICS is a flexible and powerful organisational tool for managing large complex clinical trials. However, for successful implementation the cultural, psychological, and social environment of trial participants must be accounted for, and personnel need to be educated in the basics of ICS. ClinicalTrials.gov, NCT02303964 . Registered on 28 November 2014.
Yatera, Kazuhiro; Yamasaki, Kei; Nishida, Chinatsu; Noguchi, Shingo; Oda, Keishi; Akata, Kentarou; Nagata, Shuya; Kawanami, Yukiko; Kawanami, Toshinori; Ishimoto, Hiroshi; Mukae, Hiroshi
2014-09-01
There are several inhaled corticosteroid/long-acting β2-agonist (ICS/LABA) combinations currently used to treat asthmatic patients, but the differences in the clinical effects of these ICS/LABAs are currently unknown. We herein evaluated the effects of two currently available ICS/LABA combinations in a real-world setting. A fluticasone propionate/salmeterol combined Discus inhaler (FP/SM; 250/50 μg bid) was switched to a budesonide/formoterol Turbuhaler inhaler (BUD/FM; 160/4.5 μg two inhalations bid) and FP/SM (500/50 μg bid) was also switched to BUD/FM (160/4.5 μg four inhalations bid) in symptomatic asthmatic patients treated with FP/SM over 20 years of age. Sixty patients were enrolled in this study, and the scores of the asthma control test (ACT) and asthma control questionnaire-5 item version (ACQ5) were significantly improved 4 and 8 weeks after the switch to ICS/LABA treatments, and well-controlled asthma (ACQ5 score <0.75) and good control (ACT score >20) was achieved in 54 (90%) and 40 (66.7%) patients, respectively, at 8 weeks. The spirometric analysis revealed significant improvements of the values of the peak expiratory flow (PEF) and forced expiratory volume in one second (FEV1) after switching from FP/SM to BUD/FM, and significantly improved small airway impairments ([Formula: see text]50 and [Formula: see text]25) were observed in patients treated with high-dose ICS/LABA. These subjective and objective improvements were also seen in patients aged over 65 years old. These data demonstrated that changing the combined ICS/LABA inhaler from FP/SM to BUD/FM can lead to more effective management of symptomatic patients with asthma, especially in patients treated with high-dose ICS/LABA.
Eye Gaze and Aging: Selective and Combined Effects of Working Memory and Inhibitory Control.
Crawford, Trevor J; Smith, Eleanor S; Berry, Donna M
2017-01-01
Eye-tracking is increasingly studied as a cognitive and biological marker for the early signs of neuropsychological and psychiatric disorders. However, in order to make further progress, a more comprehensive understanding of the age-related effects on eye-tracking is essential. The antisaccade task requires participants to make saccadic eye movements away from a prepotent stimulus. Speculation on the cause of the observed age-related differences in the antisaccade task largely centers around two sources of cognitive dysfunction: inhibitory control (IC) and working memory (WM). The IC account views cognitive slowing and task errors as a direct result of the decline of inhibitory cognitive mechanisms. An alternative theory considers that a deterioration of WM is the cause of these age-related effects on behavior. The current study assessed IC and WM processes underpinning saccadic eye movements in young and older participants. This was achieved with three experimental conditions that systematically varied the extent to which WM and IC were taxed in the antisaccade task: a memory-guided task was used to explore the effect of increasing the WM load; a Go/No-Go task was used to explore the effect of increasing the inhibitory load; a 'standard' antisaccade task retained the standard WM and inhibitory loads. Saccadic eye movements were also examined in a control condition: the standard prosaccade task where the load of WM and IC were minimal or absent. Saccade latencies, error rates and the spatial accuracy of saccades of older participants were compared to the same measures in healthy young controls across the conditions. The results revealed that aging is associated with changes in both IC and WM. Increasing the inhibitory load was associated with increased reaction times in the older group, while the increased WM load and the inhibitory load contributed to an increase in the antisaccade errors. These results reveal that aging is associated with changes in both IC and WM.
NASA Astrophysics Data System (ADS)
Sano, Kimikazu; Nagatani, Munehiko; Mutoh, Miwa; Murata, Koichi
This paper is a report on a high ESD breakdown-voltage InP HBT transimpedance amplifier IC for optical video distribution systems. To make ESD breakdown-voltage higher, we designed ESD protection circuits integrated in the TIA IC using base-collector/base-emitter diodes of InP HBTs and resistors. These components for ESD protection circuits have already existed in the employed InP HBT IC process, so no process modifications were needed. Furthermore, to meet requirements for use in optical video distribution systems, we studied circuit design techniques to obtain a good input-output linearity and a low-noise characteristic. Fabricated InP HBT TIA IC exhibited high human-body-model ESD breakdown voltages (±1000V for power supply terminals, ±200V for high-speed input/output terminals), good input-output linearity (less than 2.9-% duty-cycle-distortion), and low noise characteristic (10.7pA/√Hz averaged input-referred noise current density) with a -3-dB-down higher frequency of 6.9GHz. To the best of our knowledge, this paper is the first literature describing InP ICs with high ESD-breakdown voltages.
Factors associated with vaginal birth after cesarean in a maternity hospital of Rio de Janeiro.
d'Orsi, E; Chor, D; Giffin, K; Barbosa, G P; Angulo-Tuesta, A J; Gama, A S; Pessoa, L G; Shiraiwa, T; Fonseca, M J
2001-08-01
Identifying characteristics associated with vaginal birth after cesarean. Case-control study based on medical records. women with previous cesarean, who had delivered in a public Rio de Janeiro maternity hospital between 1992 and 1996. 141 cases (vaginal births after cesarean) and 304 controls (a new cesarean after other(s)). Multivariate analysis with logistic regression was carried out. The following characteristics were associated with greater probability of vaginal birth (IC=95%): only one previous cesarean (OR=19.05; IC=6.88-52.76); cervical dilatation at admission above 3 cm (OR=8.86; IC=4.93-15.94); gestational age below 37 weeks (OR=3.01; IC=1.40-6.46); history of at least one previous vaginal birth (OR=2.12; IC=1.18-3.82); level of education below high school (OR=1.94; IC=1.02-3.69). Chronic hypertension reduced the chances of vaginal birth (OR=0.44; IC=0.22-0.88). Among the factors that can be modified to reduce the number of repeated cesareans are: trial of labor promotion, reducing admission of women at early stages of labor and adequate hypertension management during pregnancy. Among the factors that can be modified to reduce the number of repeated cesareans are: the trial of labor promotion for women who present previous cesarean, reducing admission of women at early stages of labor and adequate hypertension management during pregnancy.
The quest for solvable multistate Landau-Zener models
Sinitsyn, Nikolai A.; Chernyak, Vladimir Y.
2017-05-24
Recently, integrability conditions (ICs) in mutistate Landau-Zener (MLZ) theory were proposed. They describe common properties of all known solved systems with linearly time-dependent Hamiltonians. Here we show that ICs enable efficient computer assisted search for new solvable MLZ models that span complexity range from several interacting states to mesoscopic systems with many-body dynamics and combinatorially large phase space. This diversity suggests that nontrivial solvable MLZ models are numerous. Additionally, we refine the formulation of ICs and extend the class of solvable systems to models with points of multiple diabatic level crossing.
Wells, Karen E; Cajigal, Sonia; Peterson, Edward L; Ahmedani, Brian K; Kumar, Rajesh; Lanfear, David E; Burchard, Esteban G; Williams, L Keoki
2016-05-01
Inhaled corticosteroids (ICSs) are the preferred treatment for achieving asthma control. However, little is known regarding the factors contributing to treatment response and whether treatment response differs by population group. We sought to assess behavioral, sociodemographic, and genetic factors related to ICS response among African American and European American subjects with asthma. Study participants were part of the Study of Asthma Phenotypes and Pharmacogenomic Interactions by Race-ethnicity (SAPPHIRE). The analytic sample included asthmatic subjects aged 12 to 56 years with greater than 12% bronchodilator reversibility and percent predicted FEV1 of between 40% and 90%. Participants received 6 weeks of inhaled beclomethasone dipropionate. The primary measure of ICS response was a change in Asthma Control Test (ACT) score; the secondary measure was a change in prebronchodilator FEV1. Adherence was measured with electronic monitors. Genetic ancestry was estimated for African American participants by using genome-wide genotype data. There were 339 study participants; 242 self-identified as African American and 97 as European American. Baseline ACT score, percent predicted FEV1, degree of bronchodilator response, and ICS adherence were significantly associated with ICS response. A baseline ACT score of 19 or less was useful in identifying those who would respond, as evidenced by the significant dose-response relationship with ICS adherence. Neither self-reported race-ethnicity among all participants nor proportion of African ancestry among African American participants was associated with ICS responsiveness. Our findings suggest that baseline lung function measures and self-reported asthma control predict ICS response, whereas self-reported race-ethnicity and genetic ancestry do not. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Treatment outcomes of overweight children and parents in the medical home.
Quattrin, Teresa; Roemmich, James N; Paluch, Rocco; Yu, Jihnhee; Epstein, Leonard H; Ecker, Michelle A
2014-08-01
To test in the primary care setting the short- and long-term efficacy of a behavioral intervention that simultaneously targeted an overweight child and parent versus an information control (IC) targeting weight control only in the child. Two- to 5-year-old children who had BMI ≥85th percentile and an overweight parent (BMI >25 kg/m2) were randomized to Intervention or IC, both receiving diet and activity education over 12 months (13 sessions) followed by 12-month follow-up (3 sessions). Parents in the Intervention group were also targeted for weight control and received behavioral intervention. Pediatricians in 4 practices enrolled their patients with the assistance of embedded recruiters (Practice Enhancement Assistants) who assisted with treatment too. A total of 96 of the 105 children randomized (Intervention n = 46; IC n = 50) started the program and had data at baseline. Children in the Intervention experienced greater reductions in percent over BMI (group × months; P = .002) and z-BMI (group × months; P < 0.001) compared with IC throughout treatment and follow-up. Greater BMI reduction was observed over time for parents in the Intervention compared with IC (P < .001) throughout treatment and follow-up. Child weight changes were correlated with parent weight changes at 12 and 24 months (r = 0.38 and 0.26; P < .001 and P = .03). Concurrently targeting preschool-aged overweight and obese youth and their parents in primary care with behavioral intervention results in greater decreases in child percent over BMI, z-BMI, and parent BMI compared with IC. The difference between Intervention and IC persists after 12 months of follow-up. Copyright © 2014 by the American Academy of Pediatrics.
[Anticaries effectiveness of fluoride toothpaste: a meta-analysis].
Chaves, Sônia Cristina Lima; Vieira-da-Silva, Lígia Maria
2002-10-01
To carry out a meta-analysis on the effectiveness of fluoride toothpaste for reducing dental caries to calculate the effect size of different hypothesis. MEDLINE and LILACS databases were studied in the period from 1980 to 1998. To evaluate the quality of the studies, methodological rigor criteria proposed by Kay & Locker (1996) were applied after the criteria were submitted to an expert committee of CNPq (National Scientific Council of Brazil) senior researchers. Of 43 papers selected, 22 met the proposed criteria. The effect size of intervention was calculated from differences among the groups and the overall effect of five groups of hypothesis. The high concentration of fluoride in the toothpaste is associated with a larger effect (overall effect = -0.17 CI 95% -0.22/-0.12). The largest caries reductions were observed when comparing fluoride toothpastes and no fluoride toothpastes (overall effect = -0.29 IC 95% -0.34/-0.24). The addiction of antimicrobial agents (overall effect = -0.03 IC 95% -0.07/+0.02), differences in abrasive systems (overall effect = -0.02 IC 95% -0.09/+0.04) and active components do not increase the effectiveness of fluoride toothpastes (overall effect = -0.04 IC 95% -0.10/+0.01). The highest caries reductions were seen in studies where there was supervised tooth brushing. This review reinforced the importance of tooth brushing with fluoride toothpastes for controlling dental caries. However it showed the emphasis put on medical approaches for disease control rather than specific educational actions. The heterogeneity of the results shows the need to consider issues such as the scenario for implementing preventive methods in the evaluation process.
Smy, Laura; Shaw, Kaitlyn; Amstutz, Ursula; Smith, Anne; Berger, Howard; Carleton, Bruce; Koren, Gideon
2016-07-20
Cortisol is a hormone involved in many physiological functions including fetal maturation and epigenetic programming during pregnancy. This study aimed to use hair cortisol as a biomarker of chronic inhaled corticosteroid (ICS) exposure and assess the potential effects of asthma on the hypothalamic-pituitary-adrenal (HPA) axis in pregnant women. We hypothesized that pregnant women with asthma treated with ICS would exhibit lower hair cortisol concentrations, indicative of adrenal suppression, compared to women with asthma not using ICS and women who do not have asthma. We performed an observational retrospective cohort study. Hair samples were analyzed from pregnant women with asthma, with (n = 56) and without (n = 31) ICS treatment, and pregnant women without asthma (n = 31). Hair samples were segmented based on the growth rate of 1 cm/month and analyzed by enzyme immunoassay to provide cortisol concentrations corresponding to preconception, trimesters 1-3, and postpartum. Hair cortisol concentrations were compared within and among the groups using non-parametric statistical tests. Hair cortisol concentrations increased across trimesters for all three groups, but this increase was dampened in women with asthma (P = 0.03 for Controls vs. ICS Treated and Controls vs. No ICS). ICS Treated women taking more than five doses per week had hair cortisol concentrations 47 % lower in third trimester than Controls. Linear regression of the third trimester hair cortisol results identified asthma as a significant factor when comparing consistent ICS use or asthma as the predictor (F(1, 25) = 9.7, P = 0.005, R(2) adj = 0.257). Hair cortisol successfully showed the expected change in cortisol over the course of pregnancy and may be a useful biomarker of HPA axis function in pregnant women with asthma. The potential impact of decreased maternal cortisol in women with asthma on perinatal outcomes remains to be determined.
A PEMFC hybrid electric vehicle real time control system
NASA Astrophysics Data System (ADS)
Sun, Hongqiao
In recent years, environmental friendly technologies and alternative energy solutions have drawn a lot of public attentions due to global energy crisis and pollution issues. Fuel cell (FC), a technology invented almost at the same time as the internal combustion (IC) engine, is now the focus of the automotive industry again. The fuel cell vehicle (FCV) has zero emission and its efficiency is significantly higher than the conventional IC engine power vehicles. Among a variety of FCV technologies, proton exchange membrane (PEM) FC vehicle appears to be far more attractive and mature. The prototype PEMFC vehicle has been developed and demonstrated to the public by nearly all the major automotive manufacturers in recent years. However, to the interest of the public research, publications and documentations on the PEMFC vehicle technology are rarely available due to its proprietary nature, which essentially makes it a secured technology. This dissertation demonstrates a real world application of a PEMFC hybrid electric vehicle. Through presenting the vehicle design concept, developing the real time control system and generating generic operation principles, this dissertation targets at establishing the public knowledge base on this new technology. A complete PEMFC hybrid electric vehicle design, including vehicle components layout, process flow diagram, real time control system architecture, subsystem structures and control algorithms, is presented in order to help understand the whole vehicle system. The design concept is validated through the vehicle demonstration. Generic operating principles are established along with the validation process, which helps populate this emerging technology. Thereafter, further improvements and future research directions are discussed.
Methods of instruction of the incident command system and related topics at US veterinary schools.
Smith, Joe S; Kuldau, Gretchen A
2014-12-01
The Incident Command System (ICS) is an adaptable construct designed to streamline response efforts to a disaster or other incident. We aimed to examine the methods used to teach the ICS at US veterinary schools and to explore alternative and novel methods for instruction of this material. A total of 29 US accredited veterinary schools (as of February 2012) were surveyed, and 18 of the 29 schools responded. The ICS and related topics were taught by both classroom methods and online instruction by most of the surveyed schools. Several of the schools used readily available Federal Emergency Management Agency and US Department of Agriculture resources to aid in instruction. Most schools used one course to teach the ICS, and some schools also used unique methods such as field exercises, drills, side-by-side training with disaster response teams, elective courses, extracurricular clubs, and externships to reinforce the ICS and related topics. Some of the surveyed institutions also utilized fourth-year clinical rotations and field deployments during actual disasters as a component of their ICS and emergency response curriculum. The ICS is being taught at some form at a significant number of US veterinary schools. Additional research is needed to evaluate the efficacy of the teaching methods of the ICS in US veterinary schools.
Langut, Yael; Talhami, Alaa; Mamidi, Samarasimhareddy; Shir, Alexei; Zigler, Maya; Joubran, Salim; Sagalov, Anna; Flashner-Abramson, Efrat; Edinger, Nufar; Klein, Shoshana; Levitzki, Alexander
2017-12-26
There is an urgent need for an effective treatment for metastatic prostate cancer (PC). Prostate tumors invariably overexpress prostate surface membrane antigen (PSMA). We designed a nonviral vector, PEI-PEG-DUPA (PPD), comprising polyethylenimine-polyethyleneglycol (PEI-PEG) tethered to the PSMA ligand, 2-[3-(1, 3-dicarboxy propyl)ureido] pentanedioic acid (DUPA), to treat PC. The purpose of PEI is to bind polyinosinic/polycytosinic acid (polyIC) and allow endosomal release, while DUPA targets PC cells. PolyIC activates multiple pathways that lead to tumor cell death and to the activation of bystander effects that harness the immune system against the tumor, attacking nontargeted neighboring tumor cells and reducing the probability of acquired resistance and disease recurrence. Targeting polyIC directly to tumor cells avoids the toxicity associated with systemic delivery. PPD selectively delivered polyIC into PSMA-overexpressing PC cells, inducing apoptosis, cytokine secretion, and the recruitment of human peripheral blood mononuclear cells (PBMCs). PSMA-overexpressing tumors in nonobese diabetic/severe combined immunodeficiency (NOD/SCID) mice with partially reconstituted immune systems were significantly shrunken following PPD/polyIC treatment, in all cases. Half of the tumors showed complete regression. PPD/polyIC invokes antitumor immunity, but unlike many immunotherapies does not need to be personalized for each patient. The potent antitumor effects of PPD/polyIC should spur its development for clinical use.
Langut, Yael; Talhami, Alaa; Mamidi, Samarasimhareddy; Shir, Alexei; Zigler, Maya; Joubran, Salim; Sagalov, Anna; Flashner-Abramson, Efrat; Edinger, Nufar; Klein, Shoshana; Levitzki, Alexander
2017-01-01
There is an urgent need for an effective treatment for metastatic prostate cancer (PC). Prostate tumors invariably overexpress prostate surface membrane antigen (PSMA). We designed a nonviral vector, PEI-PEG-DUPA (PPD), comprising polyethylenimine–polyethyleneglycol (PEI–PEG) tethered to the PSMA ligand, 2-[3-(1, 3-dicarboxy propyl)ureido] pentanedioic acid (DUPA), to treat PC. The purpose of PEI is to bind polyinosinic/polycytosinic acid (polyIC) and allow endosomal release, while DUPA targets PC cells. PolyIC activates multiple pathways that lead to tumor cell death and to the activation of bystander effects that harness the immune system against the tumor, attacking nontargeted neighboring tumor cells and reducing the probability of acquired resistance and disease recurrence. Targeting polyIC directly to tumor cells avoids the toxicity associated with systemic delivery. PPD selectively delivered polyIC into PSMA-overexpressing PC cells, inducing apoptosis, cytokine secretion, and the recruitment of human peripheral blood mononuclear cells (PBMCs). PSMA-overexpressing tumors in nonobese diabetic/severe combined immunodeficiency (NOD/SCID) mice with partially reconstituted immune systems were significantly shrunken following PPD/polyIC treatment, in all cases. Half of the tumors showed complete regression. PPD/polyIC invokes antitumor immunity, but unlike many immunotherapies does not need to be personalized for each patient. The potent antitumor effects of PPD/polyIC should spur its development for clinical use. PMID:29229829
Simultaneous detection of three lily viruses using Triplex IC-RT-PCR.
Zhang, Yubao; Wang, Yajun; Xie, Zhongkui; Yang, Guo; Guo, Zhihong; Wang, Le
2017-11-01
Viruses commonly infecting lily (Lilium spp.) include: Lily symptomless virus (LSV), Cucumber mosaic virus (CMV) and Lily mottle virus (LMoV). These viruses usually co-infect lilies causing severe economic losses in terms of quantity and quality of flower and bulb production around the world. Reliable and precise detection systems need to be developed for virus identification. We describe the development of a triplex immunocapture (IC) reverse transcription (RT) polymerase chain reaction (PCR) assay for the simultaneous detection of LSV, CMV and LMoV. The triplex IC-RT-PCR was compared with a quadruplex RT-PCR assay. Relative to the quadruplex RT-PCR, the specificity of the triplex IC-RT-PCR system for LSV, CMV and LMoV was 100% for field samples. The sensitivity of the triplex IC-RT-PCR system was 99.4%, 81.4% and 98.7% for LSV, CMV and LMoV, respectively. Agreement (κ) between the results obtained from the two tests was 0.968, 0.844 and 0.984 for LSV, CMV and LMoV, respectively. This is the first report of the simultaneous detection of LSV, CMV and LMoV in a triplex IC-RT-PCR assay. In particular we believe this convenient and reliable triplex IC-RT-PCR method could be used routinely for large-scale field surveys or crop health monitoring of lily. Copyright © 2017. Published by Elsevier B.V.
Essiben, Félix; Foumane, Pascal; de Nguefack, Marcelle Aurelie Tsafack; Eko, Filbert Eko; Njotang, Philip Nana; Enow, Robinson Mbu; Mboudou, Emile Telesphore
2016-01-01
Intermittent preventive treatment with sulfadoxine-pyrimethamine (IPTp-SP) is recommended for malaria prevention during pregnancy. We investigated factors associated with the failure of this strategy. We conducted a case-control study in two health care facilities in Yaounde, from 1 May 2014 to 30 April 2015. Pregnant women treated with IPTp-SP, hospitalized for malaria and having a positive Rapid Diagnostic Test (RDT) result (case-subjects) were compared to pregnant women treated with IPTp-SP having a negative RDT result (control-subjects). Epi Info 7 software and SPSS 18.0 software were used with P< 0.05 as significance threshold. We recruited 234 subjects, 109 (46.6%) case-subjects and 125 control-subjects (53.4%). The associated factors found were: prematurity (P=0.03; OR=1.15; IC= 0.32 - 4.10), the non-use of LLIN (P=0.006; OR= 2.31; IC= 1.26 - 4.25), a history of hospitalization for malaria (P=0.007; OR= 2.19; IC= 1.23 - 3.89), IPTp-SP administration after 28 gestational weeks (P=0.001, OR= 3.55; IC= 1.7 - 7.61). After logistic regression, prematurity (P=0.024; OR=2.01; IC=1.1-3.7) and a history of hospitalization for malaria (P=0.001; OR=2.83; IC=1.50-5.4) remained associated with IPTp-SP failure. A history of hospitalization for malaria and prematurity are independent predictor of IPTp-SP failure.
Association between lower air pressure and the onset of ischemic colitis: a case-control study.
Kimura, Takefumi; Shinji, Akihiro; Tanaka, Naoki; Koinuma, Masayoshi; Yamaura, Maki; Nagaya, Tadanobu; Joshita, Satoru; Komatsu, Michiharu; Umemura, Takeji; Horiuchi, Akira; Wada, Shuichi; Tanaka, Eiji
2017-09-01
Ischemic colitis (IC) often affects the elderly. Proarteriosclerotic factors, such as hypertension and smoking, and cardiovascular disease are considered major contributors to IC. Although a possible link between certain cerebrocardiovascular disorders and meteorological phenomena has been reported, the relationship between IC onset and weather changes remains uninvestigated. This study examined whether specific meteorological factors were associated with the occurrence of IC. We retrospectively enrolled 303 patients who had been diagnosed with IC between January 2003 and June 2010 at Suwa Red Cross Hospital in Nagano Prefecture, Japan. The meteorological data of the days on which IC patients visited the hospital (IC+ days) were compared with those of the days on which IC patients did not (IC- days). Univariate analysis indicated that IC+ days had significantly lower air pressure (P<0.001), depressed air pressure from the previous day (P<0.001), and fewer daylight hours (P<0.001), as well as higher air temperature (P=0.017), air humidity (P=0.004), wind velocity (P<0.001), and rainfall (P=0.012) compared with IC- days. Multivariate logistic regression analysis of the meteorological data showed that air pressure (odds ratio: 0.935, P<0.001) and change in air pressure from the previous day (odds ratio: 0.934, P<0.001) were related to onset of IC. Lower air pressure and decrease in air pressure from the previous day are possible novel factors associated with the development of IC.
ERIC Educational Resources Information Center
Utendale, William T.; Hastings, Paul D.
2011-01-01
Deficits in executive function, and in particular, reduced capacity to inhibit a dominant action, are a risk factor for externalizing problems (EP). Inhibitory control (IC) develops in the later preschool and early childhood periods, such that IC might not regulate EP in toddlers and younger preschoolers. Aggression was observed during peer play…
ERIC Educational Resources Information Center
Suurland, Jill; van der Heijden, Kristiaan B.; Huijbregts, Stephan C. J.; Smaling, Hanneke J. A.; de Sonneville, Leo M. J.; Van Goozen, Stephanie H. M.; Swaab, Hanna
2016-01-01
Inhibitory control (IC) and negative emotionality (NE) are both linked to aggressive behavior, but their interplay has not yet been clarified. This study examines different NE × IC interaction models in relation to aggressive behavior in 855 preschoolers (aged 2-5 years) using parental questionnaires. Hierarchical regression analyses revealed that…
BCH codes for large IC random-access memory systems
NASA Technical Reports Server (NTRS)
Lin, S.; Costello, D. J., Jr.
1983-01-01
In this report some shortened BCH codes for possible applications to large IC random-access memory systems are presented. These codes are given by their parity-check matrices. Encoding and decoding of these codes are discussed.
Acoustic trauma triggers upregulation of serotonin receptor genes
Smith, Adam R.; Kwon, Jae Hyun; Navarro, Marco; Hurley, Laura M.
2014-01-01
Hearing loss induces plasticity in excitatory and inhibitory neurotransmitter systems in auditory brain regions. Excitatory-inhibitory balance is also influenced by a range of neuromodulatory regulatory systems, but less is known about the effects of auditory damage on these networks. In this work, we studied the effects of acoustic trauma on neuromodulatory plasticity in the auditory midbrain of CBA/J mice. Quantitative PCR was used to measure the expression of serotonergic and GABAergic receptor genes in the inferior colliculus (IC) of mice that were unmanipulated, sham controls with no hearing loss, and experimental individuals with hearing loss induced by exposure to a 116 dB, 10 kHz pure tone for 3 hours. Acoustic trauma induced substantial hearing loss that was accompanied by selective upregulation of two serotonin receptor genes in the IC. The Htr1B receptor gene was upregulated tenfold following trauma relative to shams, while the Htr1A gene was upregulated threefold. In contrast, no plasticity in serotonin receptor gene expression was found in the hippocampus, a region also innervated by serotonergic projections. Analyses in the IC demonstrated that acoustic trauma also changed the coexpression of genes in relation to each other, leading to an overexpression of Htr1B compared to other genes.. These data suggest that acoustic trauma induces serotonergic plasticity in the auditory system, and that this plasticity may involve comodulation of functionally-linked receptor genes. PMID:24997228
Water quality monitoring of Jialing-River in Chongqing using advanced ion chromatographic system.
Tanaka, Kazuhiko; Shi, Chao-Hong; Nakagoshi, Nobukazu
2012-04-01
The water quality monitoring operation to evaluate the water quality of polluted river is an extremely important task for the river-watershed management/control based on the environmental policy. In this study, the novel, simple and convenient water quality monitoring of Jialing-River in Chongqing, China was carried out using an advanced ion chromatography (IC) consisting of ion-exclusion/cation-exchange chromatography (IEC/CEC) with conductivity detection for determining simultaneously the common anions such as SO4(2-), Cl(-), and NO3(-) and the cations such as Na+, NH4+, K+, Mg2+, and Ca2+, the ion-exclusion chromatography (IEC) with visible detection for determining simultaneously the nutrient components such as phosphate and silicate ions, and the IEC with the enhanced conductivity detection using a post column of K+-form cation-exchange resin for determining HCO3(-)-alkalinity as an inorganic-carbon source for biomass synthesis in biological reaction process under the aerobic conditions. According to the ionic balance theory between the total equivalent concentrations of anions and cations, the water quality evaluation of the Jialing-River waters taking at different sampling sites in Chongqing metropolitan area was carried out using the advanced IC system. As a result, the effectiveness of this novel water quality monitoring methodology using the IC system was demonstrated on the several practical applications to a typical biological sewage treatment plant on Jialing-River of Chongqing.
NASA Astrophysics Data System (ADS)
Jarboe, N.; Minnett, R.; Constable, C.; Koppers, A. A.; Tauxe, L.
2013-12-01
The Magnetics Information Consortium (MagIC) is dedicated to supporting the paleomagnetic, geomagnetic, and rock magnetic communities through the development and maintenance of an online database (http://earthref.org/MAGIC/), data upload and quality control, searches, data downloads, and visualization tools. While MagIC has completed importing some of the IAGA paleomagnetic databases (TRANS, PINT, PSVRL, GPMDB) and continues to import others (ARCHEO, MAGST and SECVR), further individual data uploading from the community contributes a wealth of easily-accessible rich datasets. Previously uploading of data to the MagIC database required the use of an Excel spreadsheet using either a Mac or PC. The new method of uploading data utilizes an HTML 5 web interface where the only computer requirement is a modern browser. This web interface will highlight all errors discovered in the dataset at once instead of the iterative error checking process found in the previous Excel spreadsheet data checker. As a web service, the community will always have easy access to the most up-to-date and bug free version of the data upload software. The filtering search mechanism of the MagIC database has been changed to a more intuitive system where the data from each contribution is displayed in tables similar to how the data is uploaded (http://earthref.org/MAGIC/search/). Searches themselves can be saved as a permanent URL, if desired. The saved search URL could then be used as a citation in a publication. When appropriate, plots (equal area, Zijderveld, ARAI, demagnetization, etc.) are associated with the data to give the user a quicker understanding of the underlying dataset. The MagIC database will continue to evolve to meet the needs of the paleomagnetic, geomagnetic, and rock magnetic communities.
Kolozsvari, Nicoleta O; Kaneva, Pepa; Brace, Chantalle; Chartrand, Genevieve; Vaillancourt, Marilou; Cao, Jiguo; Banaszek, Daniel; Demyttenaere, Sebastian; Vassiliou, Melina C; Fried, Gerald M; Feldman, Liane S
2011-07-01
Little evidence exists to guide educators in the best way to implement simulation within surgical skills curricula. This study investigated whether practicing a basic Fundamentals of Laparoscopic Surgery (FLS) simulator task [peg transfer (PT)] facilitates learning a more complex skill [intracorporeal suturing (ICS)] and compared the effect of PT training to mastery with training to the passing level on PT retention and on learning ICS. For this study, 98 surgically naïve subjects were randomized to one of three PT training groups: control, standard training, and overtraining. All the participants then trained in ICS. The learning curves for ICS were analyzed by estimating the learning plateau and rate using nonlinear regression. Skill retention was assessed by retesting participants 1 month after training. The groups were compared using analysis of variance (ANOVA). Effectiveness of skill transfer was calculated using the transfer effectiveness ratio (TER). Data are presented as mean±standard deviation (p<0.05). The study was completed by 77 participants (28 control, 26 standard, and 23 overtrained subjects). The ICS learning plateau rose with increasing PT training (452±10 vs. 459±10 vs. 467±10; p<0.01). Increased PT training was associated with a trend toward higher initial ICS scores (128±107 vs. 127±110 vs. 183±106; p=0.13) and faster learning rates (15±4 vs. 14±4 vs. 13±4 trials; p=0.10). At retention, there were no differences in PT scores (p=0.5). The PT training took 20±10 min for standard training and 39±20 min for overtraining (p<0.01). Overtrained participants saved 11±5 min in ICS training compared with the control subjects (p=0.04). However, TER was 0.165 for the overtraining group and 0.160 for the standard training group, suggesting that PT overtraining took longer than the time saved on ICS training. For surgically naïve subjects, part-task training with PT alone was associated with slight improvements in the learning curve for ICS. However, overtraining with PT did not improve skill retention, and peg training alone was not an efficient strategy for learning ICS.
Vera, Pedro L; Preston, David M; Moldwin, Robert M; Erickson, Deborah R; Mowlazadeh, Behzad; Ma, Fei; Kouzoukas, Dimitrios E; Meyer-Siegler, Katherine L; Fall, Magnus
2018-06-01
To investigate whether urinary levels of macrophage migration inhibitory factor (MIF) are elevated in interstitial cystitis/bladder pain syndrome (IC/BPS) patients with Hunner lesions and also whether urine MIF is elevated in other forms of inflammatory cystitis. Urine samples were assayed for MIF by enzyme-linked immunosorbent assay. Urine samples from 3 female groups were examined: IC/BPS patients without (N = 55) and with Hunner lesions (N = 43), and non-IC/BPS patients (N = 100; control group; no history of IC/BPS; cancer or recent bacterial cystitis). Urine samples from 3 male groups were examined: patients with bacterial cystitis (N = 50), radiation cystitis (N = 18) and noncystitis patients (N = 119; control group; negative for bacterial cystitis). Urine MIF (mean MIF pg/mL ± standard error of the mean) was increased in female IC/BPS patients with Hunner lesions (2159 ± 435.3) compared with IC/BPS patients without Hunner lesions (460 ± 114.5) or non-IC/BPS patients (414 ± 47.6). Receiver operating curve analyses showed that urine MIF levels discriminated between the 2 IC groups (area under the curve = 72%; confidence interval 61%-82%). Male patients with bacterial and radiation cystitis had elevated urine MIF levels (2839 ± 757.1 and 4404 ± 1548.1, respectively) compared with noncystitis patients (681 ± 75.2). Urine MIF is elevated in IC/BPS patients with Hunner lesions and also in patients with other bladder inflammatory and painful conditions. MIF may also serve as a noninvasive biomarker to select IC/BPS patients more accurately for endoscopic evaluation and possible anti-inflammatory treatment. Copyright © 2018 Elsevier Inc. All rights reserved.
A survey. Financial accounting and internal control functions pursued by hospital boards.
Gavin, T A
1984-09-01
Justification for a board committee's existence is its ability to devote time to issues judged to be important by the full board. This seems to have happened. Multiple committees pursue more functions than the other committee structures. Boards lacking an FA/IC committee pursue significantly fewer functions than their counterparts with committees. Substantial respondent agreement exists on those functions most and least frequently pursued, those perceived to be most and least important, and those perceived to be most and least effectively undertaken. Distinctions between committee structures and the full board, noted in the previous paragraph, hold true with respect to the importance of functions. All board structures identified reviewing the budget and comparing it to actual results as important. Committee structures are generally more inclined to address functions related to the work of the independent auditor and the effectiveness of the hospital's system and controls than are full board structures. Functions related to the internal auditor are pursued least frequently by all FA/IC board structures. The following suggestions are made to help boards pay adequate attention to and obtain objective information about the financial affairs of their hospitals. Those boards that do not have some form of an FA/IC committee should consider starting one. Evidence shows chief financial officers have been a moving force in establishing and strengthening such committees. Boards having a joint or single committee structure should consider upgrading their structure to either a single committee or multiple committees respectively. The complexity of the healthcare environment requires that more FA/IC functions be addressed by the board. The board or its FA/IC committee(s) should meet with their independent CPA's, fiscal intermediary auditors, and internal auditors. Where the hospital lacks an internal audit function a study should be undertaken to determine the feasibility of initiating such a function. In most cases, the benefits derived from an independent, properly staffed internal audit function far exceed the cost of such a function.
Antioxidant activities of methanol extract of Sambucus ebulus L. flower.
Ebrahimzadeh, M A; Nabavi, S F; Nabavi, S M
2009-03-01
In this study antioxidant activity of methanol extract of Sambucus ebulus L. flower was investigated employing various in vitro assay systems, i.e., DPPH and nitric oxide radical scavenging, hydrogen peroxide scavenging, reducing power, iron ion chelating power and linoleic acid. IC50 for DPPH radical-scavenging activity was 228 +/- 12 microg mL(-1). The extract showed very high activity in the reducing power assay that was comparable with positive control, vitamin C. The extract showed good nitric oxide-scavenging activity (IC50 = 309 +/- 14 microg mL(-1). It was found that antioxidant activity was dose dependent i.e., activity was increased with the increase of their concentrations. The extract showed very weak activity in iron ion chelating (IC50 = 1.3 +/- 0.07 mg mL(-1)). It is showed very good activity in scavenging of hydrogen'peroxide. IC50 for scavenging of extract was 59.5 +/- 3.3 mcirog mL(-1). The extracts exhibited no activity in linoleic acid model. The total phenolic content of flower was 56.3 +/- 2.81 mg gallic acid equivalent g(-1) of extract powder and total flavonoid content was 14.5 +/- 0.72 mg quercetin equivalent g(-1) of extract powder by reference to standard curve.
Stool-based biomarkers of interstitial cystitis/bladder pain syndrome.
Braundmeier-Fleming, A; Russell, Nathan T; Yang, Wenbin; Nas, Megan Y; Yaggie, Ryan E; Berry, Matthew; Bachrach, Laurie; Flury, Sarah C; Marko, Darlene S; Bushell, Colleen B; Welge, Michael E; White, Bryan A; Schaeffer, Anthony J; Klumpp, David J
2016-05-18
Interstitial cystitis/bladder pain syndrome (IC) is associated with significant morbidity, yet underlying mechanisms and diagnostic biomarkers remain unknown. Pelvic organs exhibit neural crosstalk by convergence of visceral sensory pathways, and rodent studies demonstrate distinct bacterial pain phenotypes, suggesting that the microbiome modulates pelvic pain in IC. Stool samples were obtained from female IC patients and healthy controls, and symptom severity was determined by questionnaire. Operational taxonomic units (OTUs) were identified by16S rDNA sequence analysis. Machine learning by Extended Random Forest (ERF) identified OTUs associated with symptom scores. Quantitative PCR of stool DNA with species-specific primer pairs demonstrated significantly reduced levels of E. sinensis, C. aerofaciens, F. prausnitzii, O. splanchnicus, and L. longoviformis in microbiota of IC patients. These species, deficient in IC pelvic pain (DIPP), were further evaluated by Receiver-operator characteristic (ROC) analyses, and DIPP species emerged as potential IC biomarkers. Stool metabolomic studies identified glyceraldehyde as significantly elevated in IC. Metabolomic pathway analysis identified lipid pathways, consistent with predicted metagenome functionality. Together, these findings suggest that DIPP species and metabolites may serve as candidates for novel IC biomarkers in stool. Functional changes in the IC microbiome may also serve as therapeutic targets for treating chronic pelvic pain.
Reyes, Alessandra; Ferreira, Gisele E; Santos, Joyce; Mendes, Fausto M; Imparato, Jose C P; Braga, Mariana M
2013-03-01
Individual calibration (IC) for caries detection methods based on fluorescence is time-consuming, especially for paediatric dentists, if the calibration has to be performed tooth-by-tooth. However, it is not clear how this calibration actually interfere in laser fluorescence (LF) readings. This in vivo study was to verify the influence of different modes of IC on laser fluorescence (LF) readings. Ninety six occlusal and 95 buccal surfaces of 1st permanent molars were examined using LF device after IC performed on control (no IC), the examined teeth, a permanent incisor, a 1st primary molar or a 2nd primary molar. All modes of IC were performed in the same child. Wilcoxon test and Bland-Altman analysis were used to compare the readings. Intraclass correlation coefficients (ICC) were calculated. Laser fluorescence readings without prior calibration were higher than readings performed after any mode of IC and resulted in different values of ICC. After other IC modes, the LF readings were statistically similar. The absence of IC influences LF readings and LF reproducibility, but different IC methods can be considered in clinical practice. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.
Method and apparatus to debug an integrated circuit chip via synchronous clock stop and scan
Bellofatto, Ralph E [Ridgefield, CT; Ellavsky, Matthew R [Rochester, MN; Gara, Alan G [Mount Kisco, NY; Giampapa, Mark E [Irvington, NY; Gooding, Thomas M [Rochester, MN; Haring, Rudolf A [Cortlandt Manor, NY; Hehenberger, Lance G [Leander, TX; Ohmacht, Martin [Yorktown Heights, NY
2012-03-20
An apparatus and method for evaluating a state of an electronic or integrated circuit (IC), each IC including one or more processor elements for controlling operations of IC sub-units, and each the IC supporting multiple frequency clock domains. The method comprises: generating a synchronized set of enable signals in correspondence with one or more IC sub-units for starting operation of one or more IC sub-units according to a determined timing configuration; counting, in response to one signal of the synchronized set of enable signals, a number of main processor IC clock cycles; and, upon attaining a desired clock cycle number, generating a stop signal for each unique frequency clock domain to synchronously stop a functional clock for each respective frequency clock domain; and, upon synchronously stopping all on-chip functional clocks on all frequency clock domains in a deterministic fashion, scanning out data values at a desired IC chip state. The apparatus and methodology enables construction of a cycle-by-cycle view of any part of the state of a running IC chip, using a combination of on-chip circuitry and software.
SEFRE: Semiexoskeleton Rehabilitation System.
Chonnaparamutt, Winai; Supsi, Witsarut
2016-01-01
SEFRE (Shoulder-Elbow-Forearm Robotics Economic) rehabilitation system is presented in this paper. SEFRE Rehab System is composed of a robotic manipulator and an exoskeleton, so-called Forearm Supportive Mechanism (FSM). The controller of the system is developed as the Master PC consisting of five modules, that is, Intelligent Control (IC), Patient Communication (PC), Training with Game (TG), Progress Monitoring (PM), and Patient Supervision (PS). These modules support a patient to exercise with SEFRE in six modes, that is, Passive, Passive Stretching, Passive Guiding, Initiating Active, Active Assisted, and Active Resisted. To validate the advantages of the system, the preclinical trial was carried out at a national rehabilitation center. Here, the implement of the system and the preclinical results are presented as the verifications of SEFRE.
Superstorm Sandy: Implications For Designing A PostCyber Attack Power Restoration System
2016-03-31
for such progress. Phillip Allison, “ Cloak and Secure Your Critical Infrastructure, ICS and SCADA Systems: Building Security into Your Industrial...TechSvcs/Multi-stateFleetResponseWorkshopReport-02-21-13.pdf. Allison, Phillip. “ Cloak and Secure Your Critical Infrastructure, ICS and SCADA Systems
Carbachol inhibits basal and forskolin-evoked adult rat striatal acetylcholine release.
Login, I S
1997-05-27
Acutely dissociated adult rat striatal cholinergic neurons labeled with [3H]choline were used in a perifusion system to study muscarinic regulation of basal and forskolin-stimulated fractional [3H]acetylcholine ([3H]-ACh) efflux in the absence of synaptic modulation. Carbachol inhibited basal (40% maximal inhibition; IC50 approximately 0.7 microM) and forskolin-evoked release (75% inhibition; IC50 approximately 0.05 microM) in a concentration-dependent manner, and both carbachol actions were abolished with atropine. Thus, activation of striatal muscarinic cholinergic autoreceptors potently inhibits basal and adenylate cyclase-stimulated ACh release. Tonic inhibitory control of cholinergic activity by functional striatal circuitry apparently prevents detection of these important physiological interactions in slices or in situ.
Crowther, Robert G; Leicht, Anthony S; Spinks, Warwick L; Sangla, Kunwarjit; Quigley, Frank; Golledge, Jonathan
2012-01-01
The purpose of this study was to examine the effects of a 6-month exercise program on submaximal walking economy in individuals with peripheral arterial disease and intermittent claudication (PAD-IC). Participants (n = 16) were randomly allocated to either a control PAD-IC group (CPAD-IC, n = 6) which received standard medical therapy, or a treatment PAD-IC group (TPAD-IC; n = 10) which took part in a supervised exercise program. During a graded treadmill test, physiological responses, including oxygen consumption, were assessed to calculate walking economy during submaximal and maximal walking performance. Differences between groups at baseline and post-intervention were analyzed via Kruskal-Wallis tests. At baseline, CPAD-IC and TPAD-IC groups demonstrated similar walking performance and physiological responses. Postintervention, TPAD-IC patients demonstrated significantly lower oxygen consumption during the graded exercise test, and greater maximal walking performance compared to CPAD-IC. These preliminary results indicate that 6 months of regular exercise improves both submaximal walking economy and maximal walking performance, without significant changes in maximal walking economy. Enhanced walking economy may contribute to physiological efficiency, which in turn may improve walking performance as demonstrated by PAD-IC patients following regular exercise programs.
IC [Interior Communications] Electrician 3 and 2: Rate Training Manual. Revised.
ERIC Educational Resources Information Center
Naval Education and Training Command, Pensacola, FL.
The rate training manual provides information related to the tasks assigned to the Interior Communications (IC) Electricians Third and Second Class who operate and maintain the interior communications systems and associated equipment. Chapter one discusses career challenges for the IC Electrician in terms of responsibilities, advancement…
The Incident Command System: a literature review.
Jensen, Jessica; Thompson, Steven
2016-01-01
Given the foundational and the fundamental role that the Incident Command System (ICS) is intended to play in on-scene response efforts across the United States, it is important to determine what is known about the system and how this is known. Accordingly, this study addresses the following research question: 'How has research explored the ICS?'. To probe this question, a methodological review of the scant, but widening, pool of research literature directly related to the ICS was conducted. This paper reports on the findings of the analysis related to the focus, theoretical frameworks, population and sampling, methods, results, and conclusions of the existing research literature. While undertaken using different methodological approaches, the ICS research suggests that the system may be limited in its usefulness. In addition, the paper discusses the implications of the research for the state of knowledge of the system and for the direction of future research. © 2016 The Author(s). Disasters © Overseas Development Institute, 2016.
Denlinger, Loren C; Manthei, David M; Seibold, Max A; Ahn, Kwangmi; Bleecker, Eugene; Boushey, Homer A; Calhoun, William J; Castro, Mario; Chinchili, Vernon M; Fahy, John V; Hawkins, Greg A; Icitovic, Nicolina; Israel, Elliot; Jarjour, Nizar N; King, Tonya; Kraft, Monica; Lazarus, Stephen C; Lehman, Erik; Martin, Richard J; Meyers, Deborah A; Peters, Stephen P; Sheerar, Dagna; Shi, Lei; Sutherland, E Rand; Szefler, Stanley J; Wechsler, Michael E; Sorkness, Christine A; Lemanske, Robert F
2013-01-01
The function of the P2X(7) nucleotide receptor protects against exacerbation in people with mild-intermittent asthma during viral illnesses, but the impact of disease severity and maintenance therapy has not been studied. To evaluate the association between P2X(7), asthma exacerbations, and incomplete symptom control in a more diverse population. A matched P2RX7 genetic case-control was performed with samples from Asthma Clinical Research Network trial participants enrolled before July 2006, and P2X(7) pore activity was determined in whole blood samples as an ancillary study to two trials completed subsequently. A total of 187 exacerbations were studied in 742 subjects, and the change in asthma symptom burden was studied in an additional 110 subjects during a trial of inhaled corticosteroids (ICS) dose optimization. African American carriers of the minor G allele of the rs2230911 loss-of-function single nucleotide polymorphism were more likely to have a history of prednisone use in the previous 12 months, with adjustment for ICS and long-acting β(2)-agonists use (odds ratio, 2.7; 95% confidence interval, 1.2-6.2; P = 0.018). Despite medium-dose ICS, attenuated pore function predicted earlier exacerbations in incompletely controlled patients with moderate asthma (hazard ratio, 3.2; confidence interval, 1.1-9.3; P = 0.033). After establishing control with low-dose ICS in patients with mild asthma, those with attenuated pore function had more asthma symptoms, rescue albuterol use, and FEV(1) reversal (P < 0.001, 0.03, and 0.03, respectively) during the ICS adjustment phase. P2X(7) pore function protects against exacerbations of asthma and loss of control, independent of baseline severity and the maintenance therapy.
González-de Paz, Luís; Real, Jordi; Borrás-Santos, Alicia; Martínez-Sánchez, José M; Rodrigo-Baños, Virginia; Dolores Navarro-Rubio, María
2016-05-01
This population-based study using 2011-2012 Spanish National Health Survey data aimed to measure the impact of disease, health-related habits, and risk factors associated with informal caregiving. We included and matched self-reported informal caregivers [ICs] with controls (1:4) from the same survey. For each outcome, we analyzed associations between ICs and controls using linear regression or logistic regression models. ICs had 3.4 per cent more depression (OR: 1.33, 95 per cent confidence intervals [CI]:1.06, 1.68). ICs had lower social support (95 per cent CI: 1.64, 3.28), they did more housework alone (OR:3.6, 95 per cent CI:2.65, 4.89), and had greater stress (95 per cent CI:0.13, 0.83). Women ICs caring alone had more anxiety than other groups. We found no statistical association between caregivers and worse health-related habits or increased risk factors (less physical activity, smoking, drinking, and cholesterol). Our results provide evidence that health-care professionals and organizations should recognize the importance of caring for those who care.
The Development of Inhibitory Control in Early Childhood: A Twin Study from 2-3 Years
ERIC Educational Resources Information Center
Gagne, Jeffrey R.; Saudino, Kimberly J.
2016-01-01
Parent- and lab-based observer ratings were employed to examine genetic and environmental influences on continuity and change in inhibitory control (IC) in over 300 twin-pairs assessed longitudinally at 2 and 3 years of age. Genetic influences accounted for approximately 60% of the variance in parent-rated IC at both ages. Although many of the…
ERIC Educational Resources Information Center
Pauli-Pott, Ursula; Dalir, Silke; Mingebach, Tanja; Roller, Alisa; Becker, Katja
2013-01-01
Background: Inhibitory control (IC) has been regarded as a neuropsychological basic deficit and as an endophenotype of attention deficit/hyperactivity disorder (ADHD). Implicated here are mediation processes between etiological factors and ADHD symptoms. We thus analyze whether and to what extent executive IC and delay aversion (DA; i.e.,…
Estimation of Ksub Ic from slow bend precracked Charpy specimen strength ratios
NASA Technical Reports Server (NTRS)
Succop, G.; Brown, W. F., Jr.
1976-01-01
Strength ratios are reported which were derived from slow bend tests on 0.25 inch thick precracked Charpy specimens of steels, aluminum alloys, and a titanium alloy for which valid K sub Ic values were established. The strength ratios were used to develop calibration curves typical of those that could be useful in estimating K sub Ic for the purposes of alloy development of quality control.
Roadmap to Secure Control Systems in the Water Sector
2008-03-01
solutions for ICS security. The purposes of this roadmap are as follows: • Define a consensus-based framework that articulates strategies of owners and...each failure is manageable in itself • Be used as ransomware 400,000 persons, and was estimated by the Center for Disease Control (CDC) to cost a total...and focused efforts. The water sector has developed and will pursue a set of strategic goals articulating these ambitions. These goals will help
Albuquerque, T; Isaakidis, P; Das, M; Saranchuk, P; Andries, A; Misquita, D P; Khan, S; Dubois, S; Peskett, C; Browne, M
2014-03-21
Mumbai has a population of 21 million, and an increasingly recognised epidemic of drug-resistant tuberculosis (DR-TB). To describe TB infection control (IC) measures implemented in households of DR-TB patients co-infected with the human immunodeficiency virus (HIV) under a Médecins Sans Frontières programme. IC assessments were carried out in patient households between May 2012 and March 2013. A simplified, standardised assessment tool was utilised to assess the risk of TB transmission and guide interventions. Administrative, environmental and personal protective measures were tailored to patient needs. IC assessments were carried out in 29 houses. Measures included health education, segregating sleeping areas of patients, improving natural ventilation by opening windows, removing curtains and obstacles to air flow, installing fans and air extractors and providing surgical masks to patients for limited periods. Environmental interventions were carried out in 22 houses. TB IC could be a beneficial component of a comprehensive TB and HIV care programme in households and communities. Although particularly challenging in slum settings, IC measures that are feasible, affordable and acceptable can be implemented in such settings using simplified and standardised tools. Appropriate IC interventions at household level may prevent new cases of DR-TB, especially in households of patients with a lower chance of cure.
Sensors for process control Focus Team report
NASA Astrophysics Data System (ADS)
At the Semiconductor Technology Workshop, held in November 1992, the Semiconductor Industry Association (SIA) convened 179 semiconductor technology experts to assess the 15-year outlook for the semiconductor manufacturing industry. The output of the Workshop, a document entitled 'Semiconductor Technology: Workshop Working Group Reports,' contained an overall roadmap for the technology characteristics envisioned in integrated circuits (IC's) for the period 1992-2007. In addition, the document contained individual roadmaps for numerous key areas in IC manufacturing, such as film deposition, thermal processing, manufacturing systems, exposure technology, etc. The SIA Report did not contain a separate roadmap for contamination free manufacturing (CFM). A key component of CFM for the next 15 years is the use of sensors for (1) defect reduction, (2) improved product quality, (3) improved yield, (4) improved tool utilization through contamination reduction, and (5) real time process control in semiconductor fabrication. The objective of this Focus Team is to generate a Sensors for Process Control Roadmap. Implicit in this objective is the identification of gaps in current sensor technology so that research and development activity in the sensor industry can be stimulated to develop sensor systems capable of meeting the projected roadmap needs. Sensor performance features of interest include detection limit, specificity, sensitivity, ease of installation and maintenance, range, response time, accuracy, precision, ease and frequency of calibration, degree of automation, and adaptability to in-line process control applications.
Schubert, Walter
2013-01-01
Understanding biological systems at the level of their relational (emergent) molecular properties in functional protein networks relies on imaging methods, able to spatially resolve a tissue or a cell as a giant, non-random, topologically defined collection of interacting supermolecules executing myriads of subcellular mechanisms. Here, the development and findings of parameter-unlimited functional super-resolution microscopy are described—a technology based on the fluorescence imaging cycler (IC) principle capable of co-mapping thousands of distinct biomolecular assemblies at high spatial resolution and differentiation (<40 nm distances). It is shown that the subcellular and transcellular features of such supermolecules can be described at the compositional and constitutional levels; that the spatial connection, relational stoichiometry, and topology of supermolecules generate hitherto unrecognized functional self-segmentation of biological tissues; that hierarchical features, common to thousands of simultaneously imaged supermolecules, can be identified; and how the resulting supramolecular order relates to spatial coding of cellular functionalities in biological systems. A large body of observations with IC molecular systems microscopy collected over 20 years have disclosed principles governed by a law of supramolecular segregation of cellular functionalities. This pervades phenomena, such as exceptional orderliness, functional selectivity, combinatorial and spatial periodicity, and hierarchical organization of large molecular systems, across all species investigated so far. This insight is based on the high degree of specificity, selectivity, and sensitivity of molecular recognition processes for fluorescence imaging beyond the spectral resolution limit, using probe libraries controlled by ICs. © 2013 The Authors. Journal of Molecular Recognition published by John Wiley & Sons, Ltd. PMID:24375580
Installation of C-6533(XE-2)/ARC ICS in UH-1H helicopter
NASA Astrophysics Data System (ADS)
Hnat, J. A.
1980-07-01
This report documents the results of the installation of the C-6533(XE-2)/ARC ICS in UH-1H helicopter. Installation was performed at the AEL, Inc., Monmouth County Airport facility. Design of each installation was coordinated and approved by the Government. The mechanical and electrical installation drawings for the helicopter are attached as Appendix A of this report. The new ICS system consisted of new cabling, new intercoms and helmets rewired with new microphones. All four crew stations of the helicopter were reconfigured with the new system. Existing cabling for the standard ICS system remained in the aircraft but was securely stowed for later restoration of the aircraft. The helmets (4) were rewired using separate jacks for headphones and microphone lines. Transmit and receive cables were installed in the aircraft with a minimum separation of one inch between cables. A junction box was fabricated and installed on the aft end of the console to house the fan-out terminal strips. Transmit and receive lines' separation was maintained in the junction box. During the test phase the onboard radios were used with the new ICS system.
78 FR 49270 - Information Collection; MyUSA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
... Floor, Washington, DC 20405- 0001. ATTN: Hada Flowers/IC 3090-00XX; MyUSA. Instructions: Please submit...-4755. ATTN: Hada Flowers/ IC 3090-00xx; MyUSA. Please cite OMB Control No. 3090-XXXX; MyUSA, in all...
A Cooling System for the EAPU Shuttle Upgrade
NASA Technical Reports Server (NTRS)
Tongue, Stephen; Guyette, Greg; Irbeck, Bradley
2001-01-01
The Shuttle orbiter currently uses hydrazine-powered APU's for powering its hydraulic system pumps. To enhance vehicle safety and reliability, NASA is pursuing an APU upgrade where the hydrazine powered turbine is replaced by an electric motor pump and battery power supply. This EAPU (Electric APU) upgrade presents several thermal control challenges most notably the new requirement for moderate temperature control of high-power electron ics at 132 of (55.6 C). This paper describes how the existing Water Spray Boiler (WSB), which currently cools the hydraulic fluid and APU lubrication oil, is being modified to provide EAPU thermal management.
Review of the Fire Control System.
1980-11-18
TIE FIRE CONTROL SYSTEM Final Report;, CDRL #A005 a weaa . 1 VItdbu!i A UaR11.d Gy 8.Ic.80 12 05 028 W Unclassified. Uf e C’ L V A’ N ON -A iAC’ , 14 n...ta FI..Ie d) REPORT DOCUMENTATON PAREAD INSTRU-TION. PR--PAGE FRE COMPLETING FORM W 4E,’ 1 - " r ’ i:!VBE i 2 GOVT ACESSION NO. 3 RECIPIENT’S...enhancements of old applications. (continued on next page) DD 1 FAM , 1473 E ITON OF I NOV 65IS OBSOLETES.IN 0102-LF.014-6601 Unclassified SECUAITY
Study on Mine Emergency Mechanism based on TARP and ICS
NASA Astrophysics Data System (ADS)
Xi, Jian; Wu, Zongzhi
2018-01-01
By analyzing the experiences and practices of mine emergency in China and abroad, especially the United States and Australia, normative principle, risk management principle and adaptability principle of constructing mine emergency mechanism based on Trigger Action Response Plans (TARP) and Incident Command System (ICS) are summarized. Classification method, framework, flow and subject of TARP and ICS which are suitable for the actual situation of domestic mine emergency are proposed. The system dynamics model of TARP and ICS is established. The parameters such as evacuation ratio, response rate, per capita emergency capability and entry rate of rescuers are set up. By simulating the operation process of TARP and ICS, the impact of these parameters on the emergency process are analyzed, which could provide a reference and basis for building emergency capacity, formulating emergency plans and setting up action plans in the emergency process.
Lefevre, Jonas; Hankins, Catherine; Pourreaux, Karina; Voyer, Hélène; Coutlée, François
2003-12-01
High-risk human papillomavirus 16 (HPV-16) DNA viral load has been measured with real-time PCR assays by amplifying HPV-16 and a human gene. However, these assays have not used internal controls (ICs) to screen for the presence of inhibitors contained in samples. To quantitate HPV-16 DNA and cell content with real-time PCR, ICs for HPV-16 DNA and beta-globin were synthesised and used to control for inhibition. The assays were sensitive and linear over 5 logs. Good reproducibility was achieved with inter-run coefficients of variation of 23% (10(2) HPV-16 copies), 12% (10(4) HPV-16 copies), 17% (274 beta-globin DNA copies) and 7% (27,400 beta-globin DNA copies). Samples containing 56,800,000, 306,000, 18,000, and 4,070 HPV-16 copies/microg of cellular DNA were tested blindly and estimated to contain 48,800,000, 479,000, 20,300, and 6,620 HPV-16 copies/microg of DNA (mean ratio of measured to expected viral load of 1.27+/-0.32). Inhibition of amplification of HPV-16 and beta-globin ICs by six samples known to contain PCR inhibitors was variable: four inhibited both ICs while two inhibited only the HPV-16 IC. The use of internal controls with real-time PCR for HPV-16 quantitation allows to screen for the presence of inhibitors that do not affect equally primer-driven genomic amplification.
Chen, Xiang-Wu; Zhao, Ying-Xi
2017-01-01
AIM To compare the diagnostic performance of isolated-check visual evoked potential (icVEP) and standard automated perimetry (SAP), for evaluating the application values of icVEP in the detection of early glaucoma. METHODS Totally 144 subjects (288 eyes) were enrolled in this study. icVEP testing was performed with the Neucodia visual electrophysiological diagnostic system. A 15% positive-contrast (bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects. Signal-to-noise ratios (SNR) were derived based on a multivariate statistic. The eyes were judged as abnormal if the test yielded an SNR≤1. SAP testing was performed with the Humphrey Field Analyzer II. The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits; or the pattern standard deviation with P<0.05; or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P<0.05, one of which must have a P<0.01. Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information. Moorfields regression analysis (MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph (HRT). RESULTS When the disc photograph grader was used as diagnostic standard, the sensitivity for SAP and icVEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively. When the MRA Classifier was used as the diagnostic standard, the sensitivity for SAP and icVEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively. When the combined structural assessment was used as the diagnostic standard, the sensitivity for SAP and icVEP was 59.2% and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely. There was no statistical significance between the sensitivity or specificity of SAP and icVEP, regardless of which diagnostic standard was based on. CONCLUSION The diagnostic performance of icVEP is not better than that of SAP in the detection of early glaucoma. PMID:28503434
Complex inner core of the Earth: The last frontier of global seismology
NASA Astrophysics Data System (ADS)
Tkalčić, Hrvoje
2015-03-01
The days when the Earth's inner core (IC) was viewed as a homogeneous solid sphere surrounded by the liquid outer core (OC) are now behind us. Due to a limited number of data sampling the IC and a lack of experimentally controlled conditions in the deep Earth studies, it has been difficult to scrutinize competitive hypotheses in this active area of research. However, a number of new concepts linking IC structure and dynamics has been proposed lately to explain different types of seismological observations. A common denominator of recent observational work on the IC is increased complexity seen in IC physical properties such as its isotropic and anisotropic structure, attenuation, inner core boundary (ICB) topography, and its rotational dynamics. For example, small-scale features have been observed to exist as a widespread phenomenon in the uppermost inner core, probably superimposed on much longer-scale features. The characterization of small-scale features sheds light on the nature of the solidification process and helps in understanding seismologically observed hemispherical dichotomy of the IC. The existence of variations in the rate and level of solidification is a plausible physical outcome in an environment where vigorous compositional convection in the OC and variations in heat exchange across the ICB may control the process of crystal growth. However, further progress is hindered by the fact that the current traveltime data of PKIKP waves traversing the IC do not allow discriminating between variations in isotropic P wave velocity and velocity anisotropy. Future studies of attenuation in the IC might provide crucial information about IC structure, although another trade-off exists—that of the relative contribution of scattering versus viscoelastic attenuation and the connection with the material properties. Future installations of dense arrays, cross paths of waves that sample the IC, and corresponding array studies will be a powerful tool to image and clearly distinguish between viscoelastic and scattering attenuation, and isotropic- and anisotropic-heterogeneity related effects on traveltimes of core-sensitive body waves. This will then inevitably contribute to a better understanding of what the IC is made of, how it solidifies and how it contributes to the generation and dynamics of the geomagnetic field.
A randomized placebo-controlled phase II study of a Pseudomonas vaccine in ventilated ICU patients.
Rello, Jordi; Krenn, Claus-Georg; Locker, Gottfried; Pilger, Ernst; Madl, Christian; Balica, Laura; Dugernier, Thierry; Laterre, Pierre-Francois; Spapen, Herbert; Depuydt, Pieter; Vincent, Jean-Louis; Bogár, Lajos; Szabó, Zsuzsanna; Völgyes, Barbara; Máñez, Rafael; Cakar, Nahit; Ramazanoglu, Atilla; Topeli, Arzu; Mastruzzo, Maria A; Jasovich, Abel; Remolif, Christian G; Del Carmen Soria, Liliana; Andresen Hernandez, Max A; Ruiz Balart, Carolina; Krémer, Ildikó; Molnár, Zsolt; von Sonnenburg, Frank; Lyons, Arthur; Joannidis, Michael; Burgmann, Heinz; Welte, Tobias; Klingler, Anton; Hochreiter, Romana; Westritschnig, Kerstin
2017-02-04
Currently, no vaccine against Pseudomonas is available. IC43 is a new, recombinant, protein (OprF/I)-based vaccine against the opportunistic pathogen, Pseudomonas aeruginosa, a major cause of serious hospital-acquired infections. IC43 has proven immunogenicity and tolerability in healthy volunteers, patients with burns, and patients with chronic lung diseases. In order to assess the immunogenicity and safety of IC43 in patients who are most at risk of acquiring Pseudomonas infections, it was evaluated in mechanically ventilated ICU patients. We conducted a randomized, placebo-controlled, partially blinded study in mechanically ventilated ICU patients. The immunogenicity of IC43 at day 14 was determined as the primary endpoint, and safety, efficacy against P. aeruginosa infections, and all-cause mortality were evaluated as secondary endpoints. Vaccinations (100 μg or 200 μg IC43 with adjuvant, or 100 μg IC43 without adjuvant, or placebo) were given twice in a 7-day interval and patients were followed up for 90 days. Higher OprF/I IgG antibody titers were seen at day 14 for all IC43 groups versus placebo (P < 0.0001). Seroconversion (≥4-fold increase in OprF/I IgG titer from days 0 to 14) was highest with 100 μg IC43 without adjuvant (80.6%). There were no significant differences in P. aeruginosa infection rates, with a low rate of invasive infections (pneumonia or bacteremia) in the IC43 groups (11.2-14.0%). Serious adverse events (SAEs) considered possibly related to therapy were reported by 2 patients (1.9%) in the group of 100 µg IC43 with adjuvant. Both SAEs resolved and no deaths were related to study treatment. Local tolerability symptoms were mild and rare (<5% of patients), a low rate of treatment-related treatment-emergent adverse events (3.1-10.6%) was observed in the IC43 groups. This phase II study has shown that IC43 vaccination of ventilated ICU patients produced a significant immunogenic effect. P. aeruginosa infection rates did not differ significantly between groups. In the absence of any difference in immune response following administration of 100 μg IC43 without adjuvant compared with 200 μg IC43 with adjuvant, the 100 μg dose without adjuvant was considered for further testing of its possible benefit of improved outcomes. There were no safety or mortality concerns. ClinicalTrials.gov, NCT00876252 . Registered on 3 April 2009.
NASA Astrophysics Data System (ADS)
Zakharova, Natalia; Piskovatsky, Nicolay; Gusev, Anatoly
2014-05-01
Development of Informational-Computational Systems (ICS) for data assimilation procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in: mathematical modeling; theory of adjoint equations and optimal control; inverse problems; numerical methods theory; numerical algebra and scientific computing. The above problems are studied in the Institute of Numerical Mathematics of the Russian Academy of Science (INM RAS) in ICS for personal computers. In this work the results on the Special data base development for ICS "INM RAS - Black Sea" are presented. In the presentation the input information for ICS is discussed, some special data processing procedures are described. In this work the results of forecast using ICS "INM RAS - Black Sea" with operational observation data assimilation are presented. This study was supported by the Russian Foundation for Basic Research (project No 13-01-00753) and by Presidium Program of Russian Academy of Sciences (project P-23 "Black sea as an imitational ocean model"). References 1. V.I. Agoshkov, M.V. Assovskii, S.A. Lebedev, Numerical simulation of Black Sea hydrothermodynamics taking into account tide-forming forces. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, pp. 5-31. 2. E.I. Parmuzin, V.I. Agoshkov, Numerical solution of the variational assimilation problem for sea surface temperature in the model of the Black Sea dynamics. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, pp. 69-94. 3. V.B. Zalesny, N.A. Diansky, V.V. Fomin, S.N. Moshonkin, S.G. Demyshev, Numerical model of the circulation of Black Sea and Sea of Azov. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, pp. 95-111. 4. Agoshkov V.I.,Assovsky M.B., Giniatulin S. V., Zakharova N.B., Kuimov G.V., Parmuzin E.I., Fomin V.V. Informational Computational system of variational assimilation of observation data "INM RAS - Black sea"// Ecological safety of coastal and shelf zones and complex use of shelf resources: Collection of scientific works. Issue 26, Volume 2. - National Academy of Sciences of Ukraine, Marine Hydrophysical Institute, Sebastopol, 2012. Pages 352-360. (In russian)
WTEC panel report on European nuclear instrumentation and controls
NASA Technical Reports Server (NTRS)
White, James D.; Lanning, David D.; Beltracchi, Leo; Best, Fred R.; Easter, James R.; Oakes, Lester C.; Sudduth, A. L.
1991-01-01
Control and instrumentation systems might be called the 'brain' and 'senses' of a nuclear power plant. As such they become the key elements in the integrated operation of these plants. Recent developments in digital equipment have allowed a dramatic change in the design of these instrument and control (I&C) systems. New designs are evolving with cathode ray tube (CRT)-based control rooms, more automation, and better logical information for the human operators. As these new advanced systems are developed, various decisions must be made about the degree of automation and the human-to-machine interface. Different stages of the development of control automation and of advanced digital systems can be found in various countries. The purpose of this technology assessment is to make a comparative evaluation of the control and instrumentation systems that are being used for commercial nuclear power plants in Europe and the United States. This study is limited to pressurized water reactors (PWR's). Part of the evaluation includes comparisons with a previous similar study assessing Japanese technology.
Roos, Leslie E; Beauchamp, Kathryn G; Pears, Katherine C; Fisher, Philip A; Berkman, Elliot T; Capaldi, Deborah
2017-01-01
Adolescents with prenatal substance (drug and alcohol) exposure exhibit inhibitory control (IC) deficits and aberrations in associated neural function. Nearly all research to date examines exposure to individual substances, and a minimal amount is known about the effects of heterogeneous exposure-which is more representative of population exposure levels. Using functional magnetic resonance imaging (fMRI), we investigated IC (Go/NoGo) in heterogeneously exposed (n = 7) vs. control (n = 7) at-risk adolescents (ages 13-17). The fMRI results indicated multiple IC processing differences consistent with a more immature developmental profile for exposed adolescents (Exposed > Nonexposed: NoGo > Go: right ventrolateral prefrontal cortex, right cuneus, and left inferior parietal lobe; NoGo > false alarm: occipital lobe; Go > false alarm: right anterior prefrontal cortex). Simple effects suggest exposed adolescents exhibited exaggerated correct trial but decreased incorrect trial activation. Results provide initial evidence that prenatal exposure across substances creates similar patterns of atypical brain activation to IC success and failure.
Biological effects of low-dose ionizing radiation exposure on interventional cardiologists.
Zakeri, F; Hirobe, T; Akbari Noghabi, K
2010-09-01
Interventional cardiologists (ICs) are likely to receive high radiation exposure as a result of procedures they undertake. To assess the effects of low-dose X-ray radiation exposure on chromosomal damage and on selected indices of cellular and humoral immunity in ICs. The study population consisted of 37 ICs and 37 clinical physicians as the control group with similar age, sex and duration of employment, without any work-related exposure to ionizing radiation. Cytogenetic studies were performed by chromosome aberration analysis and immunological studies by flow cytometry, enzyme-linked immunosorbent assay and immunodiffusion techniques. The frequencies of aberrant cells, chromosome breaks and dicentrics plus centric rings were significantly higher in the exposed group compared to the control group (P < 0.05; P < 0.01; P < 0.001, respectively), without positive correlation between the frequency of dicentric and centric ring aberrations and the cumulative doses of the ICs (r = 0.24, not significant). A significant increase was observed in the expression of activation marker CD69 on TCD4(+) stimulated cells in serum immunoglobulin G and interleukin (IL)-2 (P < 0.05) and a significant decrease in serum IL-10 (P < 0.05) in the ICs compared with that of the control group. There was no statistical difference between the two groups in terms of number of white blood cells and lymphocytes, CD3(+), CD4(+) and CD8(+) T cells, CD19(+) and CD16(+) 56(+) cells and concentrations of interferon (IFN)-gamma, IL-4, IL-6 and IL-8 cytokines. While cytogenetic results show higher chromosomal damage, some immune responses are stimulated or modulated immunologically in ICs.
Ogedegbe, Gbenga; Tobin, Jonathan N; Fernandez, Senaida; Cassells, Andrea; Diaz-Gloster, Marleny; Khalida, Chamanara; Pickering, Thomas; Schwartz, Joseph E
2014-05-20
Data are limited on the implementation of evidence-based multilevel interventions targeted at blood pressure (BP) control in hypertensive blacks who receive care in low-resource primary care practices. Counseling African Americans to Control Hypertension is a cluster-randomized clinical trial in which 30 community health centers were randomly assigned to the intervention condition (IC) or usual care (UC). Patients at the IC sites received patient education, home BP monitoring, and monthly lifestyle counseling, whereas physicians attended monthly hypertension case rounds and received feedback on their patients' home BP readings and chart audits. Patients and physicians at the UC sites received printed patient education material and hypertension treatment guidelines, respectively. The primary outcome was BP control, and secondary outcomes were mean changes in systolic and diastolic BPs at 12 months, assessed with an automated BP device. A total of 1059 patients (mean age, 56 years; 28% men, 59% obese, and 36% with diabetes mellitus) were enrolled. The BP control rate was similar in both groups (IC=49.3% versus UC=44.5%; odds ratio, 1.21 [95% confidence interval, 0.90-1.63]; P=0.21). In prespecified subgroup analyses, the intervention was associated with greater BP control in patients without diabetes mellitus (IC=54.0% versus UC=44.7%; odds ratio, 1.45 [confidence interval, 1.02-2.06]); and small-sized community health centers (IC=51.1% versus UC=39.6%; odds ratio, 1.45 [confidence interval, 1.04-2.45]). A practice-based, multicomponent intervention was no better than UC in improving BP control among hypertensive blacks. Future research on the implementation of behavioral modification strategies for hypertension control in low-resource settings should focus on the development of more efficient and tailored interventions in this high-risk population. http://www.clinicaltrials.gov. Unique identifier: NCT00233220. © 2014 American Heart Association, Inc.
Tuberculosis diagnostic delay and therapy outcomes of non-national migrants in Tel Aviv, 1998-2008.
Mor, Z; Kolb, H; Lidji, M; Migliori, Gb; Leventhal, A
2013-03-21
Non-national migrants have limited access to medical therapy. This study compares diagnostic delay and treatment outcomes of non-insured non-national migrants (NINNM) with insured Israeli citizens (IC) in the Tel Aviv tuberculosis (TB) clinic between 1998 and 2008. Patient delay was the time from symptoms onset to doctor's visit, while system delay was measured from doctor visit to anti-TB therapy administration. We randomly sampled 222 NINNM and 265 IC. NINNM were younger than IC, had lower male to female ratio and fewer smoked. They had less drug/alcohol abuse, more cavitations on chest radiography, longer patient and shorter system delay. Mean patient and system delays of all patients were 25 ± 14 and 79 ± 42 days, respectively. In multivariate analysis, being NINNM, asymptomatic or smoking predicted longer patient delay, while being asymptomatic or having additional co-morbidity predicted longer system delay. Treatment success in sputum smear-positive pulmonary TB NINNM was 81% and 95.7% in IC (p=0.01). Treatment success was not associated with patient or system delay. In multivariate analysis, work security and treatment adherence predicted treatment success. NINNM had longer patient delay and worse therapy outcome, while IC had longer system delay. Both delays should be reduced. NINNM should be informed that TB therapy is free and unlinked with deportation.
Cano, Isaac; Alonso, Albert; Hernandez, Carme; Burgos, Felip; Barberan-Garcia, Anael; Roldan, Jim; Roca, Josep
2015-06-01
Extensive deployment and sustainability of integrated care services (ICS) constitute an unmet need to reduce the burden of chronic conditions. The European Union project NEXES (2008-2013) assessed the deployment of four ICS encompassing the spectrum of severity of chronic patients. The current study aims to (i) describe the open source Adaptive Case Management (ACM) system (Linkcare®) developed to support the deployment of ICS at the level of healthcare district; (ii) to evaluate its performance; and, (iii) to identify key challenges for regional deployment of ICS. We first defined a conceptual model for ICS management and execution composed of five main stages. We then specified an associated logical model considering the dynamic runtime of ACM. Finally, we implemented the four ICS as a physical model with an ICS editor to allow professionals (case managers) to play active roles in adapting the system to their needs. Instances of ICS were then run in Linkcare®. Four ICS provided a framework for evaluating the system: Wellness and Rehabilitation (W&R) (number of patients enrolled in the study (n)=173); Enhanced Care (EC) in frail chronic patients to prevent hospital admissions, (n=848); Home Hospitalization and Early Discharge (HH/ED) (n=2314); and, Support to remote diagnosis (Support) (n=7793). The method for assessment of telemedicine applications (MAST) was used for iterative evaluation. Linkcare® supports ACM with shared-care plans across healthcare tiers and offers integration with provider-specific electronic health records. Linkcare® successfully contributed to the deployment of the four ICS: W&R facilitated long-term sustainability of training effects (p<0.01) and active life style (p<0.03); EC showed significant positive outcomes (p<0.05); HH/ED reduced on average 5 in-hospital days per patient with a 30-d re-admission rate of 10%; and, Support, enhanced community-based quality forced spirometry testing (p<0.01). Key challenges for regional deployment of personalized care were identified. Linkcare® provided the required functionalities to support integrated care adopting an ACM model, and it showed adaptive potential for its implementation in different health scenarios. The research generated strategies that contributed to face the challenges of the transition toward personalized medicine for chronic patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Advanced approach to information security management system model for industrial control system.
Park, Sanghyun; Lee, Kyungho
2014-01-01
Organizations make use of important information in day-to-day business. Protecting sensitive information is imperative and must be managed. Companies in many parts of the world protect sensitive information using the international standard known as the information security management system (ISMS). ISO 27000 series is the international standard ISMS used to protect confidentiality, integrity, and availability of sensitive information. While an ISMS based on ISO 27000 series has no particular flaws for general information systems, it is unfit to manage sensitive information for industrial control systems (ICSs) because the first priority of industrial control is safety of the system. Therefore, a new information security management system based on confidentiality, integrity, and availability as well as safety is required for ICSs. This new ISMS must be mutually exclusive of an ICS. This paper provides a new paradigm of ISMS for ICSs, which will be shown to be more suitable than the existing ISMS.
Advanced Approach to Information Security Management System Model for Industrial Control System
2014-01-01
Organizations make use of important information in day-to-day business. Protecting sensitive information is imperative and must be managed. Companies in many parts of the world protect sensitive information using the international standard known as the information security management system (ISMS). ISO 27000 series is the international standard ISMS used to protect confidentiality, integrity, and availability of sensitive information. While an ISMS based on ISO 27000 series has no particular flaws for general information systems, it is unfit to manage sensitive information for industrial control systems (ICSs) because the first priority of industrial control is safety of the system. Therefore, a new information security management system based on confidentiality, integrity, and availability as well as safety is required for ICSs. This new ISMS must be mutually exclusive of an ICS. This paper provides a new paradigm of ISMS for ICSs, which will be shown to be more suitable than the existing ISMS. PMID:25136659
Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J
Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.
Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events
NASA Astrophysics Data System (ADS)
Gillam, John E.; Solevi, Paola; Oliver, Josep F.; Casella, Chiara; Heller, Matthieu; Joram, Christian; Rafecas, Magdalena
2014-08-01
The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low success rates or are computationally demanding. In this investigation alternative approaches are considered. Experimental data was taken using the AX-PET prototype and a NEMA phantom. Three methods of ICS treatment were assessed—each of which considered all possible candidate LoRs during image reconstruction. Maximum likelihood expectation maximization was used in conjunction with both standard (line-like) and novel (V-like in this investigation) detection responses modeled within the system matrix. The investigation assumed that no information other than interaction locations was available to distinguish between candidates, yet the methods assessed all provided means by which such information could be included. In all cases it was shown that the signal to noise ratio is increased using ICS events. However, only one method, which used full modeling of the ICS response in the system matrix—the V-like model—provided enhancement in all figures of merit assessed in this investigation. Finally, the optimal method of ICS incorporation was demonstrated using data from two small animals measured using the AX-PET demonstrator.
Straube, Benjamin; Green, Antonia; Sass, Katharina; Kirner-Veselinovic, André; Kircher, Tilo
2013-07-01
Gestures are an important component of interpersonal communication. Especially, complex multimodal communication is assumed to be disrupted in patients with schizophrenia. In healthy subjects, differential neural integration processes for gestures in the context of concrete [iconic (IC) gestures] and abstract sentence contents [metaphoric (MP) gestures] had been demonstrated. With this study we wanted to investigate neural integration processes for both gesture types in patients with schizophrenia. During functional magnetic resonance imaging-data acquisition, 16 patients with schizophrenia (P) and a healthy control group (C) were shown videos of an actor performing IC and MP gestures and associated sentences. An isolated gesture (G) and isolated sentence condition (S) were included to separate unimodal from bimodal effects at the neural level. During IC conditions (IC > G ∩ IC > S) we found increased activity in the left posterior middle temporal gyrus (pMTG) in both groups. Whereas in the control group the left pMTG and the inferior frontal gyrus (IFG) were activated for the MP conditions (MP > G ∩ MP > S), no significant activation was found for the identical contrast in patients. The interaction of group (P/C) and gesture condition (MP/IC) revealed activation in the bilateral hippocampus, the left middle/superior temporal and IFG. Activation of the pMTG for the IC condition in both groups indicates intact neural integration of IC gestures in schizophrenia. However, failure to activate the left pMTG and IFG for MP co-verbal gestures suggests a disturbed integration of gestures embedded in an abstract sentence context. This study provides new insight into the neural integration of co-verbal gestures in patients with schizophrenia. Copyright © 2012 Wiley Periodicals, Inc.
Tanaka, Daichi; Tsukamoto, Hayato; Suga, Tadashi; Takenaka, Saki; Hamaoka, Takafumi; Hashimoto, Takeshi; Isaka, Tadao
2018-05-26
Acute aerobic exercise improves inhibitory control (IC). This improvement is often associated with increases in perceived exertion during exercise. However, listening to music during aerobic exercise mitigates an exercise-induced increase in perceived exertion. Thus, it is hypothesized that such effects of music may interfere with exercise-induced improvements in IC. To test this hypothesis, we examined the effect of music on post-exercise IC improvements that were induced by moderate-intensity exercise. Fifteen healthy young men performed cycle ergometer exercise with music or non-music. The exercise was performed using a moderate-intensity of 60% of VO 2 peak for 30 min. The music condition was performed while listening to self-selected music. The non-music condition involved no music. To evaluate IC, the Stroop task was administered before exercise, immediately after exercise, and during the 30-min post-exercise recovery period. The rate of perceived exertion immediately before moderate-intensity exercise completed was significantly lower in music condition than in non-music condition. The IC significantly improved immediately after exercise and during the post-exercise recovery period compared to before exercise in both music and non-music conditions. The post-exercise IC improvements did not significantly differ between the two conditions. These findings indicate that self-selected music-induced mitigation of the increase in perceived exertion during moderate-intensity exercise dose not interfere with exercise-induced improvements in IC. Therefore, we suggest that listening to music may be a beneficial strategy in mitigating the increase in perceived exertion during aerobic exercise without decreasing the positive effects on IC. Copyright © 2018 Elsevier Inc. All rights reserved.
Johnson, David W.; Sperou, Arissa J.; Crotts, Jennifer; Saude, Erik; Hartling, Lisa; Stang, Antonia
2017-01-01
Objective To systematically review the literature and determine frequencies of adverse drug events (ADE) associated with pediatric asthma medications. Methods Following PRISMA guidelines, we systematically searched six bibliographic databases between January 1991 and January 2017. Study eligibility, data extraction and quality assessment were independently completed and verified by two reviewers. We included randomized control trials (RCT), case-control, cohort, or quasi-experimental studies where the primary objective was identifying ADE in children 1 month– 18 years old exposed to commercial asthma medications. The primary outcome was ADE frequency. Findings Our search identified 14,540 citations. 46 studies were included: 24 RCT, 15 cohort, 4 RCT pooled analyses, 1 case-control, 1 open-label trial and 1 quasi-experimental study. Studies examined the following drug classes: inhaled corticosteroids (ICS) (n = 24), short-acting beta-agonists (n = 10), long-acting beta-agonists (LABA) (n = 3), ICS + LABA (n = 3), Leukotriene Receptor Antagonists (n = 3) and others (n = 3). 29 studies occurred in North America, and 29 were industry funded. We report a detailed index of 406 ADE descriptions and frequencies organized by drug class. The majority of data focuses on ICS, with 174 ADE affecting 13 organ systems including adrenal and growth suppression. We observed serious ADE, although they were rare, with frequency ranging between 0.9–6% per drug. There were no confirmed deaths, except for 13 potential deaths in a LABA study including combined adult and pediatric participants. We identified substantial methodological concerns, particularly with identifying ADE and determining severity. No studies utilized available standardized causality, severity or preventability assessments. Conclusion The majority of studies focus on ICS, with adrenal and growth suppression described. Serious ADE are relatively uncommon, with no confirmed pediatric deaths. We identify substantial methodological concerns, highlighting need for standardization with future research examining pediatric asthma medication safety. PMID:28793336
Development of voice navigation system for the visually impaired by using IC tags.
Takatori, Norihiko; Nojima, Kengo; Matsumoto, Masashi; Yanashima, Kenji; Magatani, Kazushige
2006-01-01
There are about 300,000 visually impaired persons in Japan. Most of them are old persons and, cannot become skillful in using a white cane, even if they make effort to learn how to use a white cane. Therefore, some guiding system that supports the independent activities of the visually impaired are required. In this paper, we will describe about a developed white cane system that supports the independent walking of the visually impaired in the indoor space. This system is composed of colored navigation lines that include IC tags and an intelligent white cane that has a navigation computer. In our system colored navigation lines that are put on the floor of the target space from the start point to the destination and IC tags that are set at the landmark point are used for indication of the route to the destination. The white cane has a color sensor, an IC tag transceiver and a computer system that includes a voice processor. This white cane senses the navigation line that has target color by a color sensor. When a color sensor finds the target color, the white cane informs a white cane user that he/she is on the navigation line by vibration. So, only following this vibration, the user can reach the destination. However, at some landmark points, guidance is necessary. At these points, an IC tag is set under the navigation line. The cane makes communication with the tag and informs the user about the land mark pint by pre recorded voice. Ten normal subjects who were blindfolded were tested with our developed system. All of them could walk along navigation line. And the IC tag information system worked well. Therefore, we have concluded that our system will be a very valuable one to support activities of the visually impaired.
Structural and functional connectivity in the agricultural Can Revull catchment (Mallorca, Spain)
NASA Astrophysics Data System (ADS)
Calsamiglia, Aleix; García-Comendador, Julián; Fortesa, Josep; Crema, Stefano; Cavalli, Marco; Alorda, Bartomeu; Estrany, Joan
2017-04-01
Unravelling the spatio-temporal variability of the sediment transfer within a catchment represents a challenge of great importance to quantify erosion, soil redistribution and their impacts on agricultural landscape. Structural and functional connectivity have been identified as useful aspects of connectivity that may clarify how these processes are coupled or decoupled in various types of catchment sediment cascades. In this study, hydrological and sediment connectivity in a Mediterranean agricultural catchment (1.4 km2) modified through traditional drainage systems (i.e., ditches and subsurface tile drainages) was assessed during two contrasted rainfall events occurred in October 2016 (20 mm in 24 h -return period < 1 yr-, I30 6.6 mm h-1 with 32 mm accumulated in 14 days) and in December 2016 (99 mm in 24 h -return period ≈ 25 yr-, I30 23 mm h-1 with 39 mm accumulated in 14 days). A morphometric index of connectivity (IC) was calculated to study the spatial patterns of structural connectivity. The identification of the main sediment pathways -in terms of functional connectivity- was conducted by field mapping, whilst the estimation of erosion and deposition rates by the analysis of high resolution digital terrain models (i.e., 5 cm pix-1; RMSE < 0.05 m) obtained from automated digital photogrammetry and unmanned aerial vehicle (UAV). The IC estimations allowed the identification of the most (dis-)connected areas related with the anthropogenic control in the resisting forces of the catchment. On the one hand, in the upper part of the catchment, depositional compartments were created by dry-stone walls that separate agricultural properties laminating flash floods. On the other hand, in the lower part of the catchment these depositional compartments were generated by an orthogonal network of ditches situated topographically above the natural thalwegs. In its turn, the most connected areas are located in the steepest parts of the catchment under rainfed herbaceous crops without dry stone walls and also within the lowland depositional compartments where the pathways are diverted generating parallel concentrated flows because of the greater elevation of these ditches. The observed spatial patterns of functional connectivity showed significant differences between the two events, although well fitted with IC as a clear evidence of anthropogenic controls in the resisting forces. During the October 2016 event -representative of high frequency-low magnitude events in the catchment- traditional drainage systems controlled the water and sediment transfer which was mainly concentrated within the ditches. By contrast, during the event of December 2016 -representative of extreme events- this transfer process was controlled by the natural morphology of the catchment, which activated coupling mechanisms between different compartments, increasing the effective area and triggering erosion processes including the formation of rills and incipient gullies. The spatial location of the sediment mobilization and deposition areas during the extreme event in December 2016 is well fitted with the IC estimations. The application of IC, therefore, may provide useful information to improve the drainage systems design and the implementation of measures to prevent soil losses.
Sirc-cvs cytotoxicity test: an alternative for predicting rodent acute systemic toxicity.
Kitagaki, Masato; Wakuri, Shinobu; Hirota, Morihiko; Tanaka, Noriho; Itagaki, Hiroshi
2006-10-01
An in vitro crystal violet staining method using the rabbit cornea-derived cell line (SIRC-CVS) has been developed as an alternative to predict acute systemic toxicity in rodents. Seventy-nine chemicals, the in vitro cytotoxicity of which was already reported by the Multicenter Evaluation of In vitro Toxicity (MEIC) and ICCVAM/ECVAM, were selected as test compounds. The cells were incubated with the chemicals for 72 hrs and the IC(50) and IC(35) values (microg/mL) were obtained. The results were compared to the in vivo (rat or mouse) "most toxic" oral, intraperitoneal, subcutaneous and intravenous LD(50) values (mg/kg) taken from the RTECS database for each of the chemicals by using Pearson's correlation statistics. The following parameters were calculated: accuracy, sensitivity, specificity, prevalence, positive predictability, and negative predictability. Good linear correlations (Pearson's coefficient; r>0.6) were observed between either the IC(50) or the IC(35) values and all the LD(50) values. Among them, a statistically significant high correlation (r=0.8102, p<0.001) required for acute systemic toxicity prediction was obtained between the IC(50) values and the oral LD(50) values. By using the cut-off concentrations of 2,000 mg/kg (LD(50)) and 4,225 microg/mL (IC(50)), no false negatives were observed, and the accuracy was 84.8%. From this, it is concluded that this method could be used to predict the acute systemic toxicity potential of chemicals in rodents.
Johnstone, Karen A; DuBose, Amanda J; Futtner, Christopher R; Elmore, Michael D; Brannan, Camilynn I; Resnick, James L
2006-02-01
Prader-Willi syndrome (PWS) and Angelman syndrome (AS) are caused by the loss of imprinted gene expression from chromosome 15q11-q13. Imprinted gene expression in the region is regulated by a bipartite imprinting centre (IC), comprising the PWS-IC and the AS-IC. The PWS-IC is a positive regulatory element required for bidirectional activation of a number of paternally expressed genes. The function of the AS-IC appears to be to suppress PWS-IC function on the maternal chromosome through a methylation imprint acquired during female gametogenesis. Here we have placed the entire mouse locus under the control of a human PWS-IC by targeted replacement of the mouse PWS-IC with the equivalent human region. Paternal inheritance of the human PWS-IC demonstrates for the first time that a positive regulatory element in the PWS-IC has diverged. These mice show postnatal lethality and growth deficiency, phenotypes not previously attributed directly to the affected genes. Following maternal inheritance, the human PWS-IC is able to acquire a methylation imprint in mouse oocytes, suggesting that acquisition of the methylation imprint is conserved. However, the imprint is lost in somatic cells, showing that maintenance has diverged. This maternal imprinting defect results in expression of maternal Ube3a-as and repression of Ube3a in cis, providing evidence that Ube3a is regulated by its antisense and creating the first reported mouse model for AS imprinting defects.
Studies of new media radiation induced laser
NASA Technical Reports Server (NTRS)
Han, K. S.; Shiu, Y. J.; Raju, S. R.; Hwang, I. H.; Tabibi, B.
1984-01-01
Various lasants were investigated especially, 2-iodohepafluoropropane (i-C3F7I) for the direct solar pumped lasers. Optical pumping of iodine laser was achieved using a small flashlamp. Using i-C3F7I as a laser gain medium, threshold inversion density, small signal gain, and laser performance at the elevated temperature were measured. The experimental results and analysis are presented. The iodine laser kinetics of the C3F7I and IBr system were numerically simulated. The concept of a direct solar-pumped laser amplifier using (i-C3F7I) as the laser material was evaluated and several kinetic coefficients for i-C3F7I laser system were reexamined. The results are discussed.
Mentoring in 2 + 2 Programs: LISD/ACC 2 + 2 Articulation Project.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
The role of mentoring in the 2 + 2 Instrumentation and Control (I&C) articulation project between the Leander Independent School District (LISD) and Austin Community College (ACC) is discussed in this document. Following a brief history of the origin and function of the mentor, the paper explains the need for the mentoring system in the I&C…
NASA Technical Reports Server (NTRS)
Bailey, Brandon
2015-01-01
Historically security within organizations was thought of as an IT function (web sites/servers, email, workstation patching, etc.) Threat landscape has evolved (Script Kiddies, Hackers, Advanced Persistent Threat (APT), Nation States, etc.) Attack surface has expanded -Networks interconnected!! Some security posture factors Network Layer (Routers, Firewalls, etc.) Computer Network Defense (IPS/IDS, Sensors, Continuous Monitoring, etc.) Industrial Control Systems (ICS) Software Security (COTS, FOSS, Custom, etc.)
The Substitution of Ion Vapor Deposited (IVD) Aluminum for Cadmium
1990-05-25
Coating Spray 1 0.0030 15 nin a 250TF Epoxy Powder Coating Spray 1 0.0030 15 nln @ 250OF Zinc Phosphate Tank Immersion 1 0.0002 Not Required Whitford: P...1candidate protection systems. MCAIR includ ed barrier-type coatings in the corrosion inhibitors ý;iich wMY be controlled by a~r-to-ic regulations that are
Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T
2009-10-01
State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.
2013-01-01
Background The yeast Candida is one of the most frequent pathogens isolated from bloodstream infections and is associated with significant morbidity and mortality. Problems with clinical and microbiological diagnosis of invasive candidiasis (IC) have prompted the development of non-culture-based laboratory methods. Previous reports suggest that serological detection of antibodies might be useful for diagnosing systemic candidiasis. Methods Diagnosis of IC using antibodies against recombinant Candida albicans enolase (Eno) and fructose-bisphosphate aldolase (Fba1) was evaluated. Using recombinant Eno and Fba1 as coating antigens, enzyme-linked immunosorbent assays (ELISAs) were used to analyze sera from patients with candidemia (n = 101), Candida colonization (n = 50), bacteremia (n = 84), invasive aspergillosis (n = 40); and from healthy controls (n = 200). Results The results demonstrated that ELISA detection of anti-Eno and anti-Fba1 IgG distinguished IC from other pathogenic infections in patients and healthy individuals. The sensitivity, specificity, and positive and negative predictive values were 72.3%, 94.7%, 78.5% and 93% for anti-Eno, and 87.1%, 92.8%, 76.5% and 96.4% for anti-Fba1 antibodies, respectively. Combining these two tests improved sensitivity up to 90.1% and negative predictive value up to 97.1%, with specificity and positive predictive values of 90.6% and 72.2%. The tests were specific to the Candida genus and antibody titers were higher for candidemia patients than for controls. Positive antibody tests were obtained before blood culture results for 42.2% of patients for anti-Eno and 51.1% for anti-Fba1. Conclusion These data suggest that tests that detect IgG antibodies against Candida enolase and fructose-bisphosphate aldolase, especially when used in combination, could be a powerful tool for diagnosing IC. PMID:23725337
Li, Fang-Qiu; Ma, Chun-Fang; Shi, Li-Ning; Lu, Jing-Fen; Wang, Ying; Huang, Mei; Kong, Qian-Qian
2013-05-31
The yeast Candida is one of the most frequent pathogens isolated from bloodstream infections and is associated with significant morbidity and mortality. Problems with clinical and microbiological diagnosis of invasive candidiasis (IC) have prompted the development of non-culture-based laboratory methods. Previous reports suggest that serological detection of antibodies might be useful for diagnosing systemic candidiasis. Diagnosis of IC using antibodies against recombinant Candida albicans enolase (Eno) and fructose-bisphosphate aldolase (Fba1) was evaluated. Using recombinant Eno and Fba1 as coating antigens, enzyme-linked immunosorbent assays (ELISAs) were used to analyze sera from patients with candidemia (n = 101), Candida colonization (n = 50), bacteremia (n = 84), invasive aspergillosis (n = 40); and from healthy controls (n = 200). The results demonstrated that ELISA detection of anti-Eno and anti-Fba1 IgG distinguished IC from other pathogenic infections in patients and healthy individuals. The sensitivity, specificity, and positive and negative predictive values were 72.3%, 94.7%, 78.5% and 93% for anti-Eno, and 87.1%, 92.8%, 76.5% and 96.4% for anti-Fba1 antibodies, respectively. Combining these two tests improved sensitivity up to 90.1% and negative predictive value up to 97.1%, with specificity and positive predictive values of 90.6% and 72.2%. The tests were specific to the Candida genus and antibody titers were higher for candidemia patients than for controls. Positive antibody tests were obtained before blood culture results for 42.2% of patients for anti-Eno and 51.1% for anti-Fba1. These data suggest that tests that detect IgG antibodies against Candida enolase and fructose-bisphosphate aldolase, especially when used in combination, could be a powerful tool for diagnosing IC.
SiC Integrated Circuits for Power Device Drivers Able to Operate in Harsh Environments
NASA Astrophysics Data System (ADS)
Godignon, P.; Alexandru, M.; Banu, V.; Montserrat, J.; Jorda, X.; Vellvehi, M.; Schmidt, B.; Michel, P.; Millan, J.
2014-08-01
The currently developed SiC electronic devices are more robust to high temperature operation and radiation exposure damage than correspondingly rated Si ones. In order to integrate the existent SiC high power and high temperature electronics into more complex systems, a SiC integrated circuit (IC) technology capable of operation at temperatures substantially above the conventional ones is required. Therefore, this paper is a step towards the development of ICs-control electronics that have to attend the harsh environment power applications. Concretely, we present the development of SiC MESFET-based digital circuitry, able to integrate gate driver for SiC power devices. Furthermore, a planar lateral power MESFET is developed with the aim of its co-integration on the same chip with the previously mentioned SiC digital ICs technology. And finally, experimental results on SiC Schottky-gated devices irradiated with protons and electrons are presented. This development is based on the Tungsten-Schottky interface technology used for the fabrication of stable SiC Schottky diodes for the European Space Agency Mission BepiColombo.
Engdal, S; Nilsen, O G
2008-06-01
1. The herbal products Natto K2, Agaricus, mistletoe, noni juice, green tea and garlic were investigated for in vitro inhibitory potential on P-glycoprotein (P-gp)-mediated transport of digoxin (30 nM) in differentiated and polarized Caco-2 cells. 2. Satisfactory cell functionality was demonstrated through measurements of assay linearity, transepithelial electric resistance (TEER), cytotoxicity, mannitol permeability, and inclusion of the positive inhibition control verapamil. 3. The most potent inhibitors of the net digoxin flux (IC(50)) were mistletoe > Natto K2 > Agaricus > green tea (0.022, 0.62, 3.81, >4.5 mg ml(-1), respectively). Mistletoe also showed the lowest IC(25) value, close to that obtained by verapamil (1.0 and 0.5 microg ml(-1), respectively). The IC(50)/IC(25) ratio was found to be a good parameter for the determination of inhibition profiles. Garlic and noni juice were classified as non-inhibitors. 4. This study shows that mistletoe, Natto K2, Agaricus and green tea inhibit P-gp in vitro. Special attention should be paid to mistletoe due to very low IC(50) and IC(25) values and to Natto K2 due to a low IC(50) value and a low IC(50)/IC(25) ratio.
VIMOS Instrument Control Software Design: an Object Oriented Approach
NASA Astrophysics Data System (ADS)
Brau-Nogué, Sylvie; Lucuix, Christian
2002-12-01
The Franco-Italian VIMOS instrument is a VIsible imaging Multi-Object Spectrograph with outstanding multiplex capabilities, allowing to take spectra of more than 800 objects simultaneously, or integral field spectroscopy mode in a 54x54 arcsec area. VIMOS is being installed at the Nasmyth focus of the third Unit Telescope of the European Southern Observatory Very Large Telescope (VLT) at Mount Paranal in Chile. This paper will describe the analysis, the design and the implementation of the VIMOS Instrument Control System, using UML notation. Our Control group followed an Object Oriented software process while keeping in mind the ESO VLT standard control concepts. At ESO VLT a complete software library is available. Rather than applying waterfall lifecycle, ICS project used iterative development, a lifecycle consisting of several iterations. Each iteration consisted in : capture and evaluate the requirements, visual modeling for analysis and design, implementation, test, and deployment. Depending of the project phases, iterations focused more or less on specific activity. The result is an object model (the design model), including use-case realizations. An implementation view and a deployment view complement this product. An extract of VIMOS ICS UML model will be presented and some implementation, integration and test issues will be discussed.
Miconi, Diana; Altoè, Gianmarco; Salcuni, Silvia; Di Riso, Daniela; Schiff, Sami; Moscardino, Ughetta
2018-05-24
Although discrimination is a common stressor in the everyday life of immigrant youth, individuals are not equally susceptible to its adverse effects. This cross-sectional study aimed to examine whether cultural orientation preferences and impulse control (IC) moderate the association between perceived discrimination and externalizing problems among Moroccan- and Romanian-origin early adolescents in Italy. The sample included 126 Moroccan and 126 Romanian youths (46% girls, 42% first-generation) aged 11-13 years and their parents. Perceived discrimination and cultural orientations were assessed using self-report questionnaires, while IC was evaluated via a computerized version of the Iowa Gambling Task. Externalizing behaviors were assessed via parental report. Cluster analysis identified separated, assimilated, and integrated early adolescents. Regression analyses revealed that when facing discrimination, youths who endorsed separation and exhibited low levels of IC were more vulnerable to externalizing problems. In contrast, among assimilated adolescents the discrimination-externalizing difficulties link was significant at high levels of IC. Furthermore, low levels of IC were associated with more externalizing problems for Romanian, but not for Moroccan early adolescents. Findings underscore the need to consider both cultural orientation processes and early adolescents' ability to control their impulses when developing interventions aimed to reduce discrimination-related problem behaviors in immigrant youth. Implications for theory and practice are discussed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Integrated readout electronics for Belle II pixel detector
NASA Astrophysics Data System (ADS)
Blanco, R.; Leys, R.; Perić, I.
2018-03-01
This paper describes the readout components for Belle II that have been designed as integrated circuits. The ICs are connected to DEPFET sensor by bump bonding. Three types of ICs have been developed: SWITCHER for pixel matrix control, DCD for readout and digitizing of sensor signals and DHP for digital data processing. The ICs are radiation tolerant and use several novel features, such as the multiple-input differential amplifiers and the fast and radiation hard high-voltage drivers. SWITCHER and DCD have been developed at University of Heidelberg, Karlsruhe Institute of Technology (KIT) and DHP at Bonn University. The IC-development started in 2009 and was accomplished in 2016 with the submissions of final designs. The final ICs for Belle II pixel detector and the related measurement results will be presented in this contribution.
Drabek, Tomas; Janata, Andreas; Jackson, Edwin K.; End, Brad; Stezoski, Jason; Vagni, Vincent A.; Janesko-Feldman, Keri; Wilson, Caleb D.; van Rooijen, Nico; Tisherman, Samuel A.; Kochanek, Patrick M.
2014-01-01
Trauma patients who suffer cardiac arrest (CA) from exsanguination rarely survive. Emergency preservation and resuscitation using hypothermia was developed to buy time for resuscitative surgery and delayed resuscitation with cardiopulmonary bypass (CPB), but intact survival is limited by neuronal death associated with microglial proliferation and activation. Pharmacological modulation of microglia may improve outcome following CA. Systemic injection of liposome-encapsulated clodronate (LEC) depletes macrophages. To test the hypothesis that intrahippocampal injection of LEC would attenuate local microglial proliferation after CA in rats, we administered LEC or PBS into the right or left hippocampus, respectively. After rapid exsanguination and 6 min no-flow, hypothermia was induced by ice-cold (IC) or room-temperature (RT) flush. Total duration of CA was 20 min. Pre-treatment (IC, RTpre) and post-treatment (RTpost) groups were studied, along with shams (cannulation only) and CPB controls. On day 7, shams and CPB groups showed neither neuronal death nor microglial activation. In contrast, the number of microglia in hippocampus in each individual group (IC, RTpre, RTpost) was decreased with LEC vs. PBS by ~34–46% (P < 0.05). Microglial proliferation was attenuated in the IC vs. RT groups (P < 0.05). Neuronal death did not differ between hemispheres or IC vs. RT groups. Thus, intrahippocampal injection of LEC attenuated microglial proliferation by ~40%, but did not alter neuronal death. This suggests that microglia may not play a pivotal role in mediating neuronal death in prolonged hypothermic CA. This novel strategy provides us with a tool to study the specific effects of microglia in hypothermic CA. PMID:21970817
Aytac, Zeynep; Yildiz, Zehra Irem; Kayaci-Senirmak, Fatma; San Keskin, Nalan Oya; Kusku, Semran Ipek; Durgun, Engin; Tekinay, Turgay; Uyar, Tamer
2016-10-05
We have proposed a new strategy for preparing free-standing nanofibrous webs from an inclusion complex (IC) of a well-known flavor/fragrance compound (limonene) with three modified cyclodextrins (HPβCD, MβCD, and HPγCD) via electrospinning (CD/limonene-IC-NFs) without using a polymeric matrix. The experimental and computational modeling studies proved that the stoichiometry of the complexes was 1:1 for CD/limonene systems. MβCD/limonene-IC-NF released much more limonene at 37, 50, and 75 °C than HPβCD/limonene-IC-NF and HPγCD/limonene-IC-NF because of the greater amount of preserved limonene. Moreover, MβCD/limonene-IC-NF has released only 25% (w/w) of its limonene, whereas HPβCD/limonene-IC-NF and HPγCD/limonene-IC-NF released 51 and 88% (w/w) of their limonene in 100 days, respectively. CD/limonene-IC-NFs exhibited high antibacterial activity against E. coli and S. aureus. The water solubility of limonene increased significantly and CD/limonene-IC-NFs were dissolved in water in a few seconds. In brief, CD/limonene-IC-NFs with fast-dissolving character enhanced the thermal stability and prolonged the shelf life along with antibacterial properties could be quite applicable in food and oral care applications.
Active form Notch4 promotes the proliferation and differentiation of 3T3-L1 preadipocytes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lai, Peng-Yeh; Tsai, Chong-Bin; Department of Ophthalmology, Chiayi Christian Hospital, Chiayi 600, Taiwan, ROC
2013-01-18
Highlights: ► Notch4IC modulates the ERK pathway and cell cycle to promote 3T3-L1 proliferation. ► Notch4IC facilitates 3T3-L1 differentiation by up-regulating proadipogenic genes. ► Notch4IC promotes proliferation during the early stage of 3T3-L1 adipogenesis. ► Notch4IC enhances differentiation during subsequent stages of 3T3-L1 adipogenesis. -- Abstract: Adipose tissue is composed of adipocytes, which differentiate from precursor cells in a process called adipogenesis. Many signal molecules are involved in the transcriptional control of adipogenesis, including the Notch pathway. Previous adipogenic studies of Notch have focused on Notch1 and HES1; however, the role of other Notch receptors in adipogenesis remains unclear. Q-RT-PCRmore » analyses showed that the augmentation of Notch4 expression during the differentiation of 3T3-L1 preadipocytes was comparable to that of Notch1. To elucidate the role of Notch4 in adipogenesis, the human active form Notch4 (N4IC) was transiently transfected into 3T3-L1 cells. The expression of HES1, Hey1, C/EBPδ and PPARγ was up-regulated, and the expression of Pref-1, an adipogenic inhibitor, was down-regulated. To further characterize the effect of N4IC in adipogenesis, stable cells expressing human N4IC were established. The expression of N4IC promoted proliferation and enhanced differentiation of 3T3-L1 cells compared with those of control cells. These data suggest that N4IC promoted proliferation through modulating the ERK pathway and the cell cycle during the early stage of 3T3-L1 adipogenesis and facilitated differentiation through up-regulating adipogenic genes such as C/EBPα, PPARγ, aP2, LPL and HSL during the middle and late stages of 3T3-L1 adipogenesis.« less
Keller, Joseph; Chen, Yi-Kuang; Lin, Herng-Ching
2013-04-01
Although one prior study reported an association between bladder pain syndrome/interstitial cystitis (BPS/IC) and urinary calculi (UC), no population-based study to date has been conducted to explore this relationship. Therefore, using a population-based data set in Taiwan, this study set out to investigate the association between BPS/IC and a prior diagnosis of UC. This study included 9,269 cases who had received their first-time diagnosis of BPS/IC between 2006 and 2007 and 46,345 randomly selected controls. We used conditional logistic regression analysis to compute the odds ratio (OR) and its corresponding 95 % confidence interval (CI) for having been previously diagnosed with UC between cases and controls. There was a significant difference in the prevalence of prior UC between cases and controls (8.1 vs 4.3 %, p < 0.001). Conditional logistic regression analysis revealed that cases were more likely to have been previously diagnosed with UC than controls (OR = 1.70; 95 % CI = 1.56-1.84) after adjusting for chronic pelvic pain, irritable bowel syndrome, fibromyalgia, chronic fatigue syndrome, depression, panic disorder, migraine, sicca syndrome, allergy, endometriosis, and asthma. BPS/IC was found to be significantly associated with prior UC regardless of stone location; the adjusted ORs of kidney calculus, ureter calculus, bladder calculus, and unspecified calculus when compared to controls were 1.58 (95 % CI = 1.38-1.81), 1.73 (95 % CI = 1.45-2.05), 3.80 (95 % CI = 2.18-6.62), and 1.83 (95 % CI = 1.59-2.11), respectively. This work generates the hypothesis that UC may be associated with BPS/IC.
Blasier, Kiev R.; Humsi, Michael K.; Ha, Junghoon; Ross, Mitchell W.; Smiley, W. Russell; Inamdar, Nirja A.; Mitchell, David J.; Lo, Kevin W.-H.; Pfister, K. Kevin
2014-01-01
Cytoplasmic dynein is a multi-subunit motor protein responsible for intracellular cargo transport toward microtubule minus ends. There are multiple isoforms of the dynein intermediate chain (DYNC1I, IC) which is encoded by two genes. One way to regulate cytoplasmic dynein is by IC phosphorylation. The IC-2C isoform is expressed in all cells and the functional significance of phosphorylation on IC-2C serine 84 was investigated using live cell imaging of fluorescent protein-tagged wild type IC-2C (WT) and phospho- and dephospho-mimic mutant isoforms in axonal transport model systems. Both mutations modulated dynein functional properties. The dephospho-mimic mutant IC-2C S84A had greater co-localization with mitochondria than IC-2C wild-type (WT) or the phospho-mimic mutant IC-2C S84D. The dephospho-mimic mutant IC-2C S84A was also more likely to be motile than the phospho-mimic mutant IC-2C S84D or IC-2C WT. In contrast, the phospho-mimic mutant IC-2C S84D mutant was more likely to move in the retrograde direction than was the IC-2C S84A mutant. The phospho-mimic IC-2C S84D was also as likely as IC-2C WT to co-localize with mitochondria. Both the S84D phospho- and S84A, dephospho-mimic mutants were found to be capable of microtubule minus end directed (retrograde) movement in axons. They were also observed to be passively transported in the anterograde direction. These data suggest that the IC-2C S84 has a role in modulating dynein properties. PMID:24798412
Estimating Weight and Moments for Ship Control Design Technical Assessment Team Reviews
2016-07-26
01 5/ 02 0 E st im at in g W ei gh t & M om en ts fo r S C D T ec hn ic al A ss es sm en t T ea m R ev ie w s NSWCCD-80-TR-2016/020...currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 07-26-2016 2. REPORT TYPE...10 3.4.2 Distributive Systems / Other Impacts
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
30 CFR 57.22210 - In-line filters (I-C mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false In-line filters (I-C mines). 57.22210 Section... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22210 In-line filters (I-C mines). Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of...
Galioto, Rachel; O'Leary, Kevin C; Thomas, J Graham; Demos, Kathryn; Lipton, Richard B; Gunstad, John; Pavlović, Jelena M; Roth, Julie; Rathier, Lucille; Bond, Dale S
2017-12-01
Pain catastrophizing (PC) is associated with more severe and disabling migraine attacks. However, factors that moderate this relationship are unknown. Failure of inhibitory control (IC), or the ability to suppress automatic or inappropriate responses, may be one such factor given previous research showing a relationship between higher PC and lower IC in non-migraine samples, and research showing reduced IC in migraine. Therefore, we examined whether lower IC interacts with increased PC to predict greater migraine severity as measured by pain intensity, attack frequency, and duration. Women (n = 105) aged 18-50 years old (M = 38.0 ± 1.2) with overweight/obesity and migraine who were seeking behavioral treatment for weight loss and migraine reduction completed a 28-day smartphone-based headache diary assessing migraine headache severity. Participants then completed a modified computerized Stroop task as a measure of IC and self-report measures of PC (Pain Catastrophizing Scale [PCS]), anxiety, and depression. Linear regression was used to examine independent and joint associations of PC and IC with indices of migraine severity after controlling for age, body mass index (BMI) depression, and anxiety. Participants on average had BMI of 35.1 ± 6.5 kg/m 2 and reported 5.3 ± 2.6 migraine attacks (8.3 ± 4.4 migraine days) over 28 days that produced moderate pain intensity (5.9 ± 1.4 out of 10) with duration of 20.0 ± 14.2 h. After adjusting for covariates, higher PCS total (β = .241, SE = .14, p = .03) and magnification subscale (β = .311, SE = .51, p < .01) scores were significant independent correlates of longer attack duration. IC interacted with total PCS (β = 1.106, SE = .001, p = .03) rumination (β = 1.098, SE = .001, p = .04), and helplessness (β = 1.026, SE = .001, p = .04) subscale scores to predict headache pain intensity, such that the association between PC and pain intensity became more positive at lower levels of IC. Results showed that lower IC interacted with higher PC, both overall and specific subcomponents, to predict higher pain intensity during migraine attacks. Future studies are needed to determine whether interventions to improve IC could lead to less painful migraine attacks via improvements in PC.
Mutters, N T; Günther, F; Frank, U; Mischnik, A
2016-06-01
Multidrug-resistant organisms (MDROs) are an economic burden, and infection control (IC) measures are cost- and labour-intensive. A two-tier IC management strategy was developed, including active screening, in order to achieve effective use of limited resources. Briefly, high-risk patients were differentiated from other patients, distinguished according to type of MDRO, and IC measures were implemented accordingly. To evaluate costs and benefits of this IC management strategy. The study period comprised 2.5 years. All high-risk patients underwent microbiological screening. Gram-negative bacteria (GNB) were classified as multidrug-resistant (MDR) and extensively drug-resistant (XDR). Expenses consisted of costs for staff, materials, laboratory, increased workload and occupational costs. In total, 39,551 patients were screened, accounting for 24.5% of all admissions. Of all screened patients, 7.8% (N=3,104) were MDRO positive; these patients were mainly colonized with vancomycin-resistant enterococci (37.3%), followed by meticillin-resistant Staphylococcus aureus (30.3%) and MDR-GNB (28.3%). The median length of stay (LOS) for all patients was 10 days (interquartile range 3-20); LOS was twice as long in colonized patients (P<0.001). Screening costs totalled 255,093.82€, IC measures cost 97,701.36€, and opportunity costs were 599,225.52€. The savings of this IC management strategy totalled 500,941.84€. Possible transmissions by undetected carriers would have caused additional costs of 613,648.90-4,974,939.26€ (i.e. approximately 600,000-5 million €). Although the costs of a two-tier IC management strategy including active microbiological screening are not trivial, these data indicate that the approach is cost-effective when prevented transmissions are included in the cost estimate. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Ener, Kemal; Keske, Murat; Aldemir, Mustafa; Özcan, Muhammet Fuat; Okulu, Emrah; Özayar, Asım; Ergin, Merve; Doluoğlu, Ömer Gökhan; Çakmak, Serdar; Erel, Özcan
2015-08-01
This study aimed to investigate oxidative stress in etiopathogenesis by analyzing serum total antioxidant capacity (TAC), total oxidant status (TOS), binding capacity of exogenous cobalt to human albumin (IMA), serum advanced oxidation protein products (AOPP), paraoxonase (PON), arylesterase, IgE, and C-reactive protein (CRP) in bladder pain syndrome/interstitial cystitis (BPS/IC). The study included 16 female patients diagnosed with BPS/IC and 25 healthy female subjects forming the control group. A bladder biopsy was performed on all patients in the BPS/IC group by carrying out cystoscopy with hydrodistention under general anesthesia. The results of serum TAC, TOS, IMA, AOPP, PON, arylesterase, IgE, and CRP of the subjects in both groups were compared. The mean age of the 16 female patients in the BPS/IC group was 43.6 ± 14.5 years, and the mean age of the 25 healthy subjects in the control group was 42.0 ± 10.3 years. According to the criteria of International Society for the Study of Interstitial Cystitis (ESSIC), eight patients were classified as Type 2A, three patients as Type 2B, four patients as Type 2C, and one patient as Type 3C. In the BPS/IC group, while TAC was found significantly lower than in the control group, IMA, IgE, and CRP were found significantly higher (P < 0.05). When binary logistic regression analysis was performed, the created model was determined to have 81.3 % sensitivity and 80 % specifity. In the etiology of BPS/IC, mechanism of oxidative damage comes into prominence. In the diagnosis of BPS/IC, IgE, CRP, and TAC are not specific markers when used separately; however, a higher specifity and sensitivity could be reached when used jointly in the suspected patients.
Safety of inhaled corticosteroids in the treatment of persistent asthma.
Peters, Stephen P.
2006-01-01
OBJECTIVE: Inhaled corticosteroids (ICSs) are the most effective medications available for patients with persistent asthma of all severities and currently are recommended as the preferred asthma controller therapy by the National Heart, Lung and Blood Institute. Nevertheless, lingering concerns about potential adverse systemic effects of ICSs contribute to their underuse. This review discusses the safety of ICSs with respect to potential systemic effects of most concern to physicians and patients. METHODS: Articles reporting on the safety of ICSs in children and adults with persistent asthma were identified from the Medline database from January 1966 through December 2003, reference lists of review articles and international respiratory meetings. RESULTS: Ocular effects of ICSs and ICS effects on bone mineral density and adrenal function are minimal in patients maintained on recommended ICS doses. One-year growth studies in children have shown decreased growth velocity with ICSs, but long-term studies with inhaled budesonide and beclomethasone show no effect on final adult height, suggesting that these effects are transient. In addition, extensive data from the Swedish Medical Birth Registry show no increased risk of adverse perinatal outcomes when inhaled budesonide is administered to pregnant women with asthma. CONCLUSIONS: ICSs have minimal systemic effects in most patients when taken at recommended doses. The benefits of ICS therapy clearly outweigh the risks of uncontrolled asthma, and ICSs should be prescribed routinely as first-line therapy for children and adults with persistent disease. PMID:16775906
Characterization of indigenous chicken production systems in Kenya.
Okeno, Tobias O; Kahi, Alexander K; Peters, Kurt J
2012-03-01
Indigenous chicken (IC) and their production systems were characterized to understand how the whole system operates for purposes of identifying threats and opportunities for holistic improvement. A survey involving 594 households was conducted in six counties with the highest population of IC in Kenya using structured questionnaires. Data on IC farmers' management practices were collected and analysed and inbreeding levels calculated based on the effective population size. Indigenous chicken were ranked highest as a source of livestock income by households in medium- to high-potential agricultural areas, but trailed goats in arid and semi-arid areas. The production system practised was mainly low-input and small-scale free range, with mean flock size of 22.40 chickens per household. The mean effective population size was 16.02, translating to high levels of inbreeding (3.12%). Provision for food and cash income were the main reasons for raising IC, whilst high mortality due to diseases, poor nutrition, housing and marketing channels were the major constraints faced by farmers. Management strategies targeting improved healthcare, nutrition and housing require urgent mitigation measures, whilst rural access road network needs to be developed for ease of market accessibility. Sustainable genetic improvement programmes that account for farmers' multiple objectives, market requirements and the production circumstances should be developed for a full realization of IC productivity.
Assessment of Xylazine for Euthanasia of Anoles (Anolis carolinensis and Anolis distichus)
Ascher, Jill M; Bates, Wendy; Ng, Julienne; Messing, Susan; Wyatt, Jeffrey
2012-01-01
Intracoelomic (IC) injection of xylazine was evaluated as a chemical euthanasia method for Anolis lizards (Anolis carolinensis or Anolis distichus). Lizards were allocated into 5 groups of 10 animals each. Each group was euthanized by one of these methods: 10 mg xylazine (100 mg/mL) IC; 10 mg xylazine and 0.5 mg acepromazine (10 mg/mL) IC; 10 mg xylazine IC followed by intracardiac injection of 0.1 mEq KCl (2 mEq/mL) once heart beats were no longer discernable by Doppler; 500 mg/kg 1% NaCO3-buffered MS222 solution IC followed by IC injection of 0.1 mL unbuffered 50% (v/v) MS222 solution (experimental groups); and 1.95 mg sodium pentobarbital, diluted 1:10 in sterile water (38.9 mg/mL) given IC (control group). Compared with those given sodium pentobarbital or MS222, lizards euthanized by using xylazine showed prolonged persistence of purposeful movement after cardiac arrest. Therefore, xylazine is not an acceptable alternative euthanasia agent for use in anoles. PMID:22330873
Assessment of xylazine for euthanasia of anoles (Anolis carolinensis and Anolis distichus).
Ascher, Jill M; Bates, Wendy; Ng, Julienne; Messing, Susan; Wyatt, Jeffrey
2012-01-01
Intracoelomic (IC) injection of xylazine was evaluated as a chemical euthanasia method for Anolis lizards (Anolis carolinensis or Anolis distichus). Lizards were allocated into 5 groups of 10 animals each. Each group was euthanized by one of these methods: 10 mg xylazine (100 mg/mL) IC; 10 mg xylazine and 0.5 mg acepromazine (10 mg/mL) IC; 10 mg xylazine IC followed by intracardiac injection of 0.1 mEq KCl (2 mEq/mL) once heart beats were no longer discernable by Doppler; 500 mg/kg 1% NaCO(3)-buffered MS222 solution IC followed by IC injection of 0.1 mL unbuffered 50% (v/v) MS222 solution (experimental groups); and 1.95 mg sodium pentobarbital, diluted 1:10 in sterile water (38.9 mg/mL) given IC (control group). Compared with those given sodium pentobarbital or MS222, lizards euthanized by using xylazine showed prolonged persistence of purposeful movement after cardiac arrest. Therefore, xylazine is not an acceptable alternative euthanasia agent for use in anoles.
Airborne multicamera system for geo-spatial applications
NASA Astrophysics Data System (ADS)
Bachnak, Rafic; Kulkarni, Rahul R.; Lyle, Stacey; Steidley, Carl W.
2003-08-01
Airborne remote sensing has many applications that include vegetation detection, oceanography, marine biology, geographical information systems, and environmental coastal science analysis. Remotely sensed images, for example, can be used to study the aftermath of episodic events such as the hurricanes and floods that occur year round in the coastal bend area of Corpus Christi. This paper describes an Airborne Multi-Spectral Imaging System that uses digital cameras to provide high resolution at very high rates. The software is based on Delphi 5.0 and IC Imaging Control's ActiveX controls. Both time and the GPS coordinates are recorded. Three successful test flights have been conducted so far. The paper present flight test results and discusses the issues being addressed to fully develop the system.
A pre- and post-intervention study of infection control in equine hospitals in Sweden
2014-01-01
Background Detection of nosocomial methicillin-resistant Staphylococcus aureus infections in horses in Sweden has increased attention on infection control (IC) in equine hospitals. This study established baseline data on IC programmes within such settings, evaluated compliance with some IC procedures before and after an education intervention, and examined barriers to compliance. The study was carried out between 2008 and 2011 in four Swedish equine hospitals. Data on current IC of each hospital, purchase data on hand sanitisers and disposable gloves per patient, and direct observations of compliance with procedures were monitored pre- and post-intervention. The intervention comprised a lecture on common IC and a review of each hospital’s current procedures. For comparison, retrospective purchase data were reviewed. A questionnaire on individual compliance, experiences and opinions of IC was issued to employees. Results Three hospitals completed the study, while the fourth reported its IC procedures and completed the questionnaire. Actual numbers of procedures, content and level of documentation differed among the hospitals. Similarities were poor or absent IC implementation strategy, lack of active surveillance of compliance with procedures and no monitoring of such as nosocomial infections. Among the hospitals which completed the study, two reported pre-intervention observation of compliance, while all three reported post-intervention observations. The purchase data showed trends for changes over time, although not uniformly related to the intervention. One hospital demonstrated a significant post-intervention increase in compliance with glove procedures, accompanied by a non-significant post-intervention increase in purchases figures. Compliance with dress code and personal appearance was high in all three hospitals (92-100%), while compliance with hand hygiene procedures was generally poorer. Barriers to compliance cited in the questionnaire (data from four hospitals) included insufficient supplies of hygiene products, lack of readily accessible places for cleaning, insufficient knowledge and high workload. Conclusions Potential for easily attainable improvements in IC, such as traceability of documents, implementation strategies and surveillance of efficacy, was revealed. Attention to hand hygiene implementation and improvement of logistics appeared important. Data on purchases per patient were readily available and therefore applicable for intra-hospital surveillance of IC trends over time. PMID:25146752
DOT National Transportation Integrated Search
2017-08-01
Intelligent Compaction (IC) technique is a fast-developing technology for base and soil compaction quality control. Proof-rolling subgrades and bases using IC rollers upon completion of compaction can identify the less stiff spots and significantly i...
Shin, Jung-Youn; Jeong, Jee-Heon; Han, Jin; Bhang, Suk Ho; Jeong, Gun-Jae; Haque, Muhammad R.; Al-Hilal, Taslim A.; Noh, Myungkyung
2015-01-01
Although islet transplantation has been suggested as an alternative therapy for type 1 diabetes, there are efficiency concerns that are attributed to poor engraftment of transplanted islets. Hypoxic condition and delayed vasculogenesis induce necrosis and apoptosis of the transplanted islets. To overcome these limitations in islet transplantation, heterospheroids (HSs), which consist of rat islet cells (ICs) and human bone marrow-derived mesenchymal stem cells (hMSCs), were transplanted to the kidney and liver. The HSs cultured under the hypoxic condition system exhibited a significant increase in antiapoptotic gene expression in ICs. hMSCs in the HSs secreted angiogenic and antiapoptotic proteins. With the HS system, ICs and hMSCs were successfully located in the same area of the liver after transplantation of HSs through the portal vein, whereas the transplantation of islets and the dissociated hMSCs did not result in localization of transplanted ICs and hMSCs in the same area. HS transplantation resulted in an increase in angiogenesis at the transplantation area and a decrease in the apoptosis of transplanted ICs after transplantation into the kidney subcapsule compared with transplantation of islet cell clusters (ICCs). Insulin production levels of ICs were higher in the HS transplantation group compared with the ICC transplantation group. The HS system may be a more efficient transplantation method than the conventional methods for the treatment of type 1 diabetes. PMID:25344077
Cloutier, Nathalie; Allaeys, Isabelle; Marcoux, Genevieve; Machlus, Kellie R; Mailhot, Benoit; Zufferey, Anne; Levesque, Tania; Becker, Yann; Tessandier, Nicolas; Melki, Imene; Zhi, Huiying; Poirier, Guy; Rondina, Matthew T; Italiano, Joseph E; Flamand, Louis; McKenzie, Steven E; Cote, Francine; Nieswandt, Bernhard; Khan, Waliul I; Flick, Matthew J; Newman, Peter J; Lacroix, Steve; Fortin, Paul R; Boilard, Eric
2018-02-13
There is a growing appreciation for the contribution of platelets to immunity; however, our knowledge mostly relies on platelet functions associated with vascular injury and the prevention of bleeding. Circulating immune complexes (ICs) contribute to both chronic and acute inflammation in a multitude of clinical conditions. Herein, we scrutinized platelet responses to systemic ICs in the absence of tissue and endothelial wall injury. Platelet activation by circulating ICs through a mechanism requiring expression of platelet Fcγ receptor IIA resulted in the induction of systemic shock. IC-driven shock was dependent on release of serotonin from platelet-dense granules secondary to platelet outside-in signaling by αIIbβ3 and its ligand fibrinogen. While activated platelets sequestered in the lungs and leaky vasculature of the blood-brain barrier, platelets also sequestered in the absence of shock in mice lacking peripheral serotonin. Unexpectedly, platelets returned to the blood circulation with emptied granules and were thereby ineffective at promoting subsequent systemic shock, although they still underwent sequestration. We propose that in response to circulating ICs, platelets are a crucial mediator of the inflammatory response highly relevant to sepsis, viremia, and anaphylaxis. In addition, platelets recirculate after degranulation and sequestration, demonstrating that in adaptive immunity implicating antibody responses, activated platelets are longer lived than anticipated and may explain platelet count fluctuations in IC-driven diseases.
Duzel, Antonija; Vlainic, Josipa; Antunovic, Marko; Malekinusic, Dominik; Vrdoljak, Borna; Samara, Mariam; Gojkovic, Slaven; Krezic, Ivan; Vidovic, Tinka; Bilic, Zdenko; Knezevic, Mario; Sever, Marko; Lojo, Nermin; Kokot, Antonio; Kolovrat, Marijan; Drmic, Domagoj; Vukojevic, Jaksa; Kralj, Tamara; Kasnik, Katarina; Siroglavic, Marko; Seiwerth, Sven; Sikiric, Predrag
2017-12-28
To provide new insights in treatment of colitis and ischemia and reperfusion in rats using stable gastric pentadecapeptide BPC 157. Medication [BPC 157, L-NAME, L-arginine (alone/combined), saline] was bath at the blood deprived colon segment. During reperfusion, medication was BPC 157 or saline. We recorded (USB microscope camera) vessel presentation through next 15 min of ischemic colitis (IC-rats) or reperfusion (removed ligations) (IC + RL-rats); oxidative stress as MDA (increased (IC- and IC + RL-rats)) and NO levels (decreased (IC-rats); increased (IC + RL-rats)) in colon tissue. IC + OB-rats [IC-rats had additional colon obstruction (OB)] for 3 d (IC + OB-rats), then received BPC 157 bath. Commonly, in colon segment (25 mm, 2 ligations on left colic artery and vein, 3 arcade vessels within ligated segment), in IC-, IC + RL-, IC + OB-rats, BPC 157 (10 μg/kg) bath (1 mL/rat) increased vessel presentation, inside/outside arcade interconnections quickly reappeared, mucosal folds were preserved and the pale areas were small and markedly reduced. BPC 157 counteracted worsening effects induced by L-NAME (5 mg) and L-arginine (100 mg). MDA- and NO-levels were normal in BPC 157 treated IC-rats and IC + RL-rats. In addition, on day 10, BPC 157-treated IC + OB-rats presented almost completely spared mucosa with very small pale areas and no gross mucosal defects; the treated colon segment was of normal diameter, and only small adhesions were present. BPC 157 is a fundamental treatment that quickly restores blood supply to the ischemically injured area and rapidly activates collaterals. This effect involves the NO system.
Duzel, Antonija; Vlainic, Josipa; Antunovic, Marko; Malekinusic, Dominik; Vrdoljak, Borna; Samara, Mariam; Gojkovic, Slaven; Krezic, Ivan; Vidovic, Tinka; Bilic, Zdenko; Knezevic, Mario; Sever, Marko; Lojo, Nermin; Kokot, Antonio; Kolovrat, Marijan; Drmic, Domagoj; Vukojevic, Jaksa; Kralj, Tamara; Kasnik, Katarina; Siroglavic, Marko; Seiwerth, Sven; Sikiric, Predrag
2017-01-01
AIM To provide new insights in treatment of colitis and ischemia and reperfusion in rats using stable gastric pentadecapeptide BPC 157. METHODS Medication [BPC 157, L-NAME, L-arginine (alone/combined), saline] was bath at the blood deprived colon segment. During reperfusion, medication was BPC 157 or saline. We recorded (USB microscope camera) vessel presentation through next 15 min of ischemic colitis (IC-rats) or reperfusion (removed ligations) (IC + RL-rats); oxidative stress as MDA (increased (IC- and IC + RL-rats)) and NO levels (decreased (IC-rats); increased (IC + RL-rats)) in colon tissue. IC + OB-rats [IC-rats had additional colon obstruction (OB)] for 3 d (IC + OB-rats), then received BPC 157 bath. RESULTS Commonly, in colon segment (25 mm, 2 ligations on left colic artery and vein, 3 arcade vessels within ligated segment), in IC-, IC + RL-, IC + OB-rats, BPC 157 (10 μg/kg) bath (1 mL/rat) increased vessel presentation, inside/outside arcade interconnections quickly reappeared, mucosal folds were preserved and the pale areas were small and markedly reduced. BPC 157 counteracted worsening effects induced by L-NAME (5 mg) and L-arginine (100 mg). MDA- and NO-levels were normal in BPC 157 treated IC-rats and IC + RL-rats. In addition, on day 10, BPC 157-treated IC + OB-rats presented almost completely spared mucosa with very small pale areas and no gross mucosal defects; the treated colon segment was of normal diameter, and only small adhesions were present. CONCLUSION BPC 157 is a fundamental treatment that quickly restores blood supply to the ischemically injured area and rapidly activates collaterals. This effect involves the NO system. PMID:29358856
Maternal and neonatal factors related to prematurity.
Oliveira, Laura Leismann de; Gonçalves, Annelise de Carvalho; Costa, Juvenal Soares Dias da; Bonilha, Ana Lucia de Lourenzi
2016-01-01
To identify maternal and neonatal factors associated with prematurity in the municipality of Porto Alegre. This was a population-based case-control study. The cases were newborns under 37 weeks of gestation and the controls were newborns over 37 weeks. The data came from the records of 19,457 births in the city of Porto Alegre in the year 2012 from the Information System on Live Births of the Municipal Health Department. The analysis was carried outand adjusted by a Logistic Regression according to a hierarchical model. The variables studied were allocated into three hierarchy levels: sociodemographic variables; reproductive history; and gestational and birth factors. There were 767 cases allocated and 1,534 controls in a design of a case for two controls (1:2) by simple randomization. In the final model, a statistically significant association was found for prematurity for the following variables: mother's age under 19 years old (OR=1.32; CI 95%: 1.02-1.71) or over 34 years old (OR=1.39; CI 95%: 1.12-1.72); inadequate maternal schooling for age (OR=2.11; CI 95%: 1.22-3.65); multiple pregnancies (OR=1.14; CI 95%: 1.01-1.29); C-section (OR=1.15; CI 95%: 1.03-1.29); birth weights under 2,500g (OR=4.04; CI 95%: 3.64-4.49); Apgar score at five minutes between zero and three (OR=1.47; CI 95%: 1.12-1.91); and inadequate prenatal care (OR=1.18; CI 95%: 1.02-1.36). The present study showed the most immediate consequence of prematurity for newborns by evidencing its association with worse Apgar scores and low birth weight. The following factors were also shown as possible more distal determinants of prematurity: mother's age; inadequate maternal education; multiple gestation; inadequate prenatal care; and C-section. Identificar fatores maternos e neonatais associados à prematuridade no município de Porto Alegre. Estudo do tipo caso-controle de base populacional. Os casos foram recém-nascidos com menos de 37 semanas de gestação, e os controles foram os recém-nascidos com 37 semanas ou mais. Os dados provieram dos registros de 19.457 nascimentos do município de Porto Alegre, no ano de 2012, no Sistema de Informações sobre Nascidos Vivos da Secretaria Municipal da Saúde. Foi realizada análise ajustada mediante Regressão Logística segundo modelo hierárquico. As variáveis estudadas foram alocadas em três níveis de hierarquia: variáveis sociodemográficas; história reprodutiva; fatores gestacionais e de nascimento. Foram alocados 767 casos e 1.534 controles, em um desenho de um caso para dois controles (1:2), mediante randomização simples. No modelo final, foi encontrada associação estatisticamente significante para prematuridade para as seguintes variáveis: idade materna menor que 19 anos (OR=1,32; IC 95%: 1,02 - 1,71) e maior que 34 anos (OR=1,39; IC 95%: 1,12 - 1,72); escolaridade materna inadequada para a idade (OR=2,11; IC 95%: 1,22 - 3,65); gravidez múltipla (OR=1,14; IC 95%: 1,01 - 1,29); cesariana (OR=1,15; IC 95%: 1,03 - 1,29); peso ao nascer menor a 2.500g (OR=4,04; IC 95%: 3,64 - 4,49); Índice de Apgar no 5° minuto de zero a três (OR=1,47; IC 95%: 1,12 - 1,91) e pré-natal inadequado (OR=1,18; IC 95%: 1,02 - 1,36). O presente estudo evidenciou as consequências mais imediatas da prematuridade para os recém-nascidos ao revelar sua associação com piores escores de Apgar e baixo peso ao nascimento. Mostrou como possíveis determinantes mais distais de prematuridade: idade materna, educação materna inadequada, gestação múltipla, pré-natal inadequado e realização de cesariana.
Management Control of Flight Operations (OFC-01) Funds
1982-12-01
3uide to Badgeta: y an ~~q.jntContro Svst___. -mpi~,~9 Ivancevich, John M. Szilagyi ,, Jr. kndrew D. and Wallace , Jr. Marc J,, OQ~anizational Bhivior...Sz~iagyi., and Wallace term the socio-techn-Ical systems molel. Showai in Figure 2-1, the molel is an input-transfociatior.-oLtpat system. The system...anA Performance, Goo)dyear Publi-hi-Ef ’ComP~ay,-rIc. T~7777 Ivancevich, John M., Szila; yi, Jr. kardrew D., and Wallace Jr. Marc J., Readi~qct In
Kamauu, Aaron W C; DuVall, Scott L; Robison, Reid J; Liimatta, Andrew P; Wiggins, Richard H; Avrin, David E
2006-01-01
Although digital teaching files are important to radiology education, there are no current satisfactory solutions for export of Digital Imaging and Communications in Medicine (DICOM) images from picture archiving and communication systems (PACS) in desktop publishing format. A vendor-neutral digital teaching file, the Radiology Interesting Case Server (RadICS), offers an efficient tool for harvesting interesting cases from PACS without requiring modifications of the PACS configurations. Radiologists push imaging studies from PACS to RadICS via the standard DICOM Send process, and the RadICS server automatically converts the DICOM images into the Joint Photographic Experts Group format, a common desktop publishing format. They can then select key images and create an interesting case series at the PACS workstation. RadICS was tested successfully against multiple unmodified commercial PACS. Using RadICS, radiologists are able to harvest and author interesting cases at the point of clinical interpretation with minimal disruption in clinical work flow. RSNA, 2006
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
... Corporation Including Express Employment Professionals. 74,111 Alstom Transportation, Hornell, NY May 14, 2009... Serv., Server Systems, IC1, Storage, Backup. 74,316A International Business Cambridge, MA......... June 10, 2009. Machines (IBM), Global Tech Serv., Server Systems, IC1, Storage, Backup. 74,316B...
DOT National Transportation Integrated Search
2017-06-13
In recent years, there has been an increased focus on Traffic Incident Management (TIM) and : incorporation of the Incident Command System (ICS) to reduce traffic congestion on the nation's : Interstates. In fact, studies show that for every minute a...
Welch, Garry; Zagarins, Sofija E; Santiago-Kelly, Paula; Rodriguez, Zoraida; Bursell, Sven-Erik; Rosal, Milagros C; Gabbay, Robert A
2015-04-01
To compare usual diabetes care (UDC) to a comprehensive diabetes care intervention condition (IC) involving an Internet-based "diabetes dashboard" management tool used by clinicians. We used a parallel-group randomized design. Diabetes nurses, diabetes dietitians, and providers used the diabetes dashboard as a clinical decision support system to deliver a five-visit, 6-month intervention to 199 poorly controlled (HbA1c >7.5% [58 mmol/mol]) Latino type 2 diabetic (T2D) patients (mean age 55 years, 60% female) at urban community health centers. We compared this intervention to an established, in-house UDC program (n = 200) for its impact on blood glucose control and psychosocial outcomes. Recruitment and retention rates were 79.0 and 88.5%, respectively. Compared with UDC, more IC patients reached HbA1c targets of <7% (53 mmol/mol; 15.8 vs. 7.0%, respectively, P < 0.01) and <8% (64 mmol/mol; 45.2 vs. 25.3%, respectively, P < 0.001). In multiple linear regression adjusting for baseline HbA1c, adjusted mean ± SE HbA1c at follow-up was significantly lower in the IC compared with the UDC group (P < 0.001; IC 8.4 ± 0.10%; UDC 9.2 ± 0.10%). The results showed lower diabetes distress at follow-up for IC patients (40.4 ± 2.1) as compared with UDC patients (48.3 ± 2.0) (P < 0.01), and also lower social distress (32.2 ± 1.3 vs. 27.2 ± 1.4, P < 0.01). There was a similar, statistically significant (P < 0.01) improvement for both groups in the proportion of patients moving from depressed status at baseline to nondepressed at follow-up (41.8 vs. 40%; no significance between groups). The diabetes dashboard intervention significantly improved diabetes-related outcomes among Latinos with poorly controlled T2D compared with a similar diabetes team condition without access to the diabetes dashboard. © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.
Wakayama, Hisashi; Ogasawara, Tomohiko; Sato, Ai; Honda, Mamiko; Sakurai, Keiko; Uemura, Takehiro; Kasai, Daishi; Kato, Hisaaki; Tomita, Yuka; Park, Jangchul; Mizuno, Akiko; Suzuki, Masayuki
2008-11-01
Although most patients of asthma can be controlled by inhaled corticosteroid (ICS), some patients remain uncontrolled even after the introduction of ICS treatment. In management of such difficult-to-treat asthma, systematic review including additional differential diagnosis and avoidance of exacerbating factors is very important. Here we postulate a flow sheet presenting an algorithm which intends to achieve better asthma control following ATS refractory asthma guidance. For patients with poor controlled asthma even after using ICS more than moderate dose, we used the sheet in our daily outpatient management and investigated whether we could improve the control in such patients. The sheet was constructed by an algorithm which included (1) reevaluation of inhalation technique of ICS; (2) additional differential diagnosis of COPD and other similar diseases; and (3) reevaluation of presence of exacerbating factors. In our outpatient department, seven clinicians managed 22 difficult-to-treat asthma patients using this sheet. Additional factors which might worsen asthma control could be detected in 21 patients (95.5%). Firstly, smoking was disclosed in 8 patients (36.4%). Secondly, keeping pets was identified in 7 patients (31.8%). 5 patients (22.7%) were diagnosed as COPD rather than asthma and 4 patients (18.2%) were diagnosed as having rhinosinusitis. Some improvement of asthma control was achieved in 9 patients (40.9%). Reevaluation of refractory asthma patients using our newly developed flow sheet is essential and it may facilitate understanding of management of difficult-to-treat asthma.
Studies of new media radiation induced laser. Final Report, 1 February 1979-30 April 1984
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, K.S.; Shiu, Y.J.; Raju, S.R.
Various lasants were investigated especially, 2-iodohepafluoropropane (i-C3F7I) for the direct solar pumped lasers. Optical pumping of iodine laser was achieved using a small flashlamp. Using i-C3F7I as a laser gain medium, threshold inversion density, small signal gain, and laser performance at the elevated temperature were measured. The experimental results and analysis are presented. The iodine laser kinetics of the C3F7I and IBr system were numerically simulated. The concept of a direct solar-pumped laser amplifier using (i-C3F7I) as the laser material was evaluated and several kinetic coefficients for i-C3F7I laser system were reexamined. The results are discussed.
Zhang, Xinxing; Bhar, Subhradeep; Jones Lipinski, Rachel A; Han, Jungsoo; Feng, Likui
2018-01-01
Caenorhabditis elegans produces ascaroside pheromones to control its development and behavior. Even minor structural differences in the ascarosides have dramatic consequences for their biological activities. Here, we identify a mechanism that enables C. elegans to dynamically tailor the fatty-acid side chains of the indole-3-carbonyl (IC)-modified ascarosides it has produced. In response to starvation, C. elegans uses the peroxisomal acyl-CoA synthetase ACS-7 to activate the side chains of medium-chain IC-ascarosides for β-oxidation involving the acyl-CoA oxidases ACOX-1.1 and ACOX-3. This pathway rapidly converts a favorable ascaroside pheromone that induces aggregation to an unfavorable one that induces the stress-resistant dauer larval stage. Thus, the pathway allows the worm to respond to changing environmental conditions and alter its chemical message without having to synthesize new ascarosides de novo. We establish a new model for biosynthesis of the IC-ascarosides in which side-chain β-oxidation is critical for controlling the type of IC-ascarosides produced. PMID:29863473
Accelerating functional verification of an integrated circuit
Deindl, Michael; Ruedinger, Jeffrey Joseph; Zoellin, Christian G.
2015-10-27
Illustrative embodiments include a method, system, and computer program product for accelerating functional verification in simulation testing of an integrated circuit (IC). Using a processor and a memory, a serial operation is replaced with a direct register access operation, wherein the serial operation is configured to perform bit shifting operation using a register in a simulation of the IC. The serial operation is blocked from manipulating the register in the simulation of the IC. Using the register in the simulation of the IC, the direct register access operation is performed in place of the serial operation.
Sánchez, Paula; Toro-Trujillo, Esteban; Muñoz-Velandia, Oscar M; García, Angel Alberto; Fernández-Ávila, Daniel G
2018-02-07
There is strong evidence of a rise in cardiovascular risk in patients suffering from autoimmune diseases, especially in those with Sistemic Lupus Erythematosus. Until now, there are a few trials that assess the potencial benefit of statins on the incidence of cardiovascular events and on lipid profile of patients with SLE. This evidence has not been synthesized and assessed altogether. We performed a search in databases of literature published until August of 2016 (Embase, MEDLINE, Cochrane Library, SciELO, Clinical Evidence, DynaMed, Cochrane Central Register of Controlled Trials, LILACS), identifying controlled clinical trials that could estimate the impact of statins on mortality, cardiovascular events, C-reactive protein and lipid profile in patients with Systemic Lupus Erythematosus. The quality of the information available was assessed with a meta-analysis, using a random effects model, employing the RevMan 5.3 software. 6 trials and 412 patients were included in the analysis. The use of statins in patients with SLE was found to significantly reduce the levels of serum total cholesterol (mean difference [MD] -31,4 mg/dL; CI 95% -43,0; -19,9), and serum low density cholesterol (MD -31,4 mg/dL; IC 95% -43,0; -19,9), but had no impact on levels of serum triglycerides (MD 4 mg/dL; IC 95% 2,49; 6,21) and C-reactive protein (MD -0,78; IC 95% -1,43; -0,13). No evidence was found about the impact on the risk of mortality or cardiovascular events. Statins have a significant effect on the levels of serum total cholesterol, LDL cholesterol and C-reactive protein, however, more randomized controlled trials with long-term follow-up are necessary to assess the impact on mortality and cardiovascular risk. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Sensitivity Analysis of Digital I&C Modules in Protection and Safety Systems
NASA Astrophysics Data System (ADS)
Khalil Ur, Rahman; Zubair, M.; Heo, G.
2013-12-01
This research is performed to examine the sensitivity of digital Instrumentation and Control (I&C) components and modules used in regulating and protection systems architectures of nuclear industry. Fault Tree Analysis (FTA) was performed for four configurations of RPS channel architecture. The channel unavailability has been calculated by using AIMS-PSA, which comes out 4.517E-03, 2.551E-03, 2.246E-03 and 2.7613-04 for architecture configuration I, II, III and IV respectively. It is observed that unavailability decreases by 43.5 % & 50.4% by inserting partial redundancy whereas maximum reduction of 93.9 % in unavailability happens when double redundancy is inserted in architecture. Coincidence module output failure and bi-stable output failures are identified as sensitive failures by Risk Reduction Worth (RRW) and Fussell-Vesely (FV) importance. RRW highlights that risk from coincidence processor output failure can reduced by 48.83 folds and FV indicates that BP output is sensitive by 0.9796 (on a scale of 1).
Lin, Tingyou; Ho, Yingchieh; Su, Chauchin
2017-06-15
This paper presents a method of thermal balancing for monolithic power integrated circuits (ICs). An on-chip temperature monitoring sensor that consists of a poly resistor strip in each of multiple parallel MOSFET banks is developed. A temperature-to-frequency converter (TFC) is proposed to quantize on-chip temperature. A pulse-width-modulation (PWM) methodology is developed to balance the channel temperature based on the quantization. The modulated PWM pulses control the hottest of metal-oxide-semiconductor field-effect transistor (MOSFET) bank to reduce its power dissipation and heat generation. A test chip with eight parallel MOSFET banks is fabricated in TSMC 0.25 μm HV BCD processes, and total area is 900 × 914 μm². The maximal temperature variation among the eight banks can reduce to 2.8 °C by the proposed thermal balancing system from 9.5 °C with 1.5 W dissipation. As a result, our proposed system improves the lifetime of a power MOSFET by 20%.
Lin, Tingyou; Ho, Yingchieh; Su, Chauchin
2017-01-01
This paper presents a method of thermal balancing for monolithic power integrated circuits (ICs). An on-chip temperature monitoring sensor that consists of a poly resistor strip in each of multiple parallel MOSFET banks is developed. A temperature-to-frequency converter (TFC) is proposed to quantize on-chip temperature. A pulse-width-modulation (PWM) methodology is developed to balance the channel temperature based on the quantization. The modulated PWM pulses control the hottest of metal-oxide-semiconductor field-effect transistor (MOSFET) bank to reduce its power dissipation and heat generation. A test chip with eight parallel MOSFET banks is fabricated in TSMC 0.25 μm HV BCD processes, and total area is 900 × 914 μm2. The maximal temperature variation among the eight banks can reduce to 2.8 °C by the proposed thermal balancing system from 9.5 °C with 1.5 W dissipation. As a result, our proposed system improves the lifetime of a power MOSFET by 20%. PMID:28617346
Cyber Security and Resilient Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert S. Anderson
2009-07-01
The Department of Energy (DOE) Idaho National Laboratory (INL) has become a center of excellence for critical infrastructure protection, particularly in the field of cyber security. It is one of only a few national laboratories that have enhanced the nation’s cyber security posture by performing industrial control system (ICS) vendor assessments as well as user on-site assessments. Not only are vulnerabilities discovered, but described actions for enhancing security are suggested – both on a system-specific basis and from a general perspective of identifying common weaknesses and their corresponding corrective actions. These cyber security programs have performed over 40 assessments tomore » date which have led to more robust, secure, and resilient monitoring and control systems for the US electrical grid, oil and gas, chemical, transportation, and many other sectors. In addition to cyber assessments themselves, the INL has been engaged in outreach to the ICS community through vendor forums, technical conferences, vendor user groups, and other special engagements as requested. Training programs have been created to help educate all levels of management and worker alike with an emphasis towards real everyday cyber hacking methods and techniques including typical exploits that are used. The asset owner or end user has many products available for its use created from these programs. One outstanding product is the US Department of Homeland Security (DHS) Cyber Security Procurement Language for Control Systems document that provides insight to the user when specifying a new monitoring and control system, particularly concerning security requirements. Employing some of the top cyber researchers in the nation, the INL can leverage this talent towards many applications other than critical infrastructure. Monitoring and control systems are used throughout the world to perform simple tasks such as cooking in a microwave to complex ones such as the monitoring and control of the next generation fighter jets or nuclear material safeguards systems in complex nuclear fuel cycle facilities. It is the intent of this paper to describe the cyber security programs that are currently in place, the experiences and successes achieved in industry including outreach and training, and suggestions about how other sectors and organizations can leverage this national expertise to help their monitoring and control systems become more secure.« less
Hukkanen, V; Haarala, M; Nurmi, M; Klemi, P; Kiilholma, P
1996-01-01
Microbes may be involved in the pathogenesis of interstitial cystitis (IC). Adenoviruses and BK virus (BKV) can infect epithelial cells in urinary bladder and they are causative agents for hemorrhagic cystitis. We therefore studied the presence of adenovirus and BKV genomes in urinary bladder tissue specimens of patients with IC using polymerase chain reaction (PCR) and in situ hybridization (ISH). Controls were specimens from cases with transitional cell carcinoma of the bladder. Nucleic acids were extracted from paraffin sections of the bladder tissue for PCR. Primers detecting all adenovirus types were used. In situ hybridization was carried out for the paraffin sections using digoxigenin-labeled DNA probes for adenovirus and BKV. The adenovirus DNA PCR was able to detect one to two infected cells/specimen. All the seven IC cases studied and six controls were negative for adenovirus DNA by PCR and ISH. The ISH test for BKV genomes was also considered negative in IC cases and controls. The specimens which were negative in PCR tests yielded a signal with beta-globin primers, thus being amplifiable. We conclude that adenovirus and BKV do not play a major pathogenetic role in interstitial cystitis.
Joint Services Electronics Program.
1983-09-30
environment. The research is under three interrelated heads: (1) algebraic Methodologies for Control Systems design , both linear and non -linear, (2) robust...properties of the device. After study of these experimental results, we plan to design a millimeter- wave version of the Gunn device. This will...appropriate dose discretization level for an adju- stable width beam. 2) Experimental Device Fabrication In a collaborative effort with the IC design group
Automated Design Tools for Integrated Mixed-Signal Microsystems (NeoCAD)
2005-02-01
method, Model Order Reduction (MOR) tools, system-level, mixed-signal circuit synthesis and optimization tools, and parsitic extraction tools. A unique...Mission Area: Command and Control mixed signal circuit simulation parasitic extraction time-domain simulation IC design flow model order reduction... Extraction 1.2 Overall Program Milestones CHAPTER 2 FAST TIME DOMAIN MIXED-SIGNAL CIRCUIT SIMULATION 2.1 HAARSPICE Algorithms 2.1.1 Mathematical Background
Manthei, David M.; Seibold, Max A.; Ahn, Kwangmi; Bleecker, Eugene; Boushey, Homer A.; Calhoun, William J.; Castro, Mario; Chinchili, Vernon M.; Fahy, John V.; Hawkins, Greg A.; Icitovic, Nicolina; Israel, Elliot; Jarjour, Nizar N.; King, Tonya; Kraft, Monica; Lazarus, Stephen C.; Lehman, Erik; Martin, Richard J.; Meyers, Deborah A.; Peters, Stephen P.; Sheerar, Dagna; Shi, Lei; Sutherland, E. Rand; Szefler, Stanley J.; Wechsler, Michael E.; Sorkness, Christine A.; Lemanske, Robert F.
2013-01-01
Rationale: The function of the P2X7 nucleotide receptor protects against exacerbation in people with mild-intermittent asthma during viral illnesses, but the impact of disease severity and maintenance therapy has not been studied. Objectives: To evaluate the association between P2X7, asthma exacerbations, and incomplete symptom control in a more diverse population. Methods: A matched P2RX7 genetic case-control was performed with samples from Asthma Clinical Research Network trial participants enrolled before July 2006, and P2X7 pore activity was determined in whole blood samples as an ancillary study to two trials completed subsequently. Measurements and Main Results: A total of 187 exacerbations were studied in 742 subjects, and the change in asthma symptom burden was studied in an additional 110 subjects during a trial of inhaled corticosteroids (ICS) dose optimization. African American carriers of the minor G allele of the rs2230911 loss-of-function single nucleotide polymorphism were more likely to have a history of prednisone use in the previous 12 months, with adjustment for ICS and long-acting β2-agonists use (odds ratio, 2.7; 95% confidence interval, 1.2–6.2; P = 0.018). Despite medium-dose ICS, attenuated pore function predicted earlier exacerbations in incompletely controlled patients with moderate asthma (hazard ratio, 3.2; confidence interval, 1.1–9.3; P = 0.033). After establishing control with low-dose ICS in patients with mild asthma, those with attenuated pore function had more asthma symptoms, rescue albuterol use, and FEV1 reversal (P < 0.001, 0.03, and 0.03, respectively) during the ICS adjustment phase. Conclusions: P2X7 pore function protects against exacerbations of asthma and loss of control, independent of baseline severity and the maintenance therapy. PMID:23144325
Achieving Symptom Control in Patients with Moderate Asthma
Weir, Nargues A.; Levine, Stewart J.
2012-01-01
Disease severity in asthma can be classified as mild, moderate or severe based upon the frequency of symptoms or the severity of airflow obstruction. This review will focus on the treatment of youths greater than 12 years of age and adults with moderate persistent asthma. Moderate asthmatics may have daily symptoms that cause some limitation with normal daily activities and require use of a rescue inhaled short-acting beta2-agonist inhaler or experience nocturnal awakenings secondary to asthma that occur more than once per week. Furthermore, spirometry may reveal airflow obstruction with a reduction in FEV1 to between 60% and 80% of predicted. Although inhaled corticosteroids (ICS) are the primary controller medication used to modify symptoms in moderate asthmatics, additional controller medications, such as inhaled long-acting beta2-agonists (LABA), leukotriene receptor antagonists (LTRA) or theophylline, are often needed to obtain optimal disease control. While the addition of an inhaled LABA to an ICS is very effective at improving disease control in moderate asthma, concerns have arisen over the safety of LABAs, in particular the risk of asthma-related death. Therefore, consideration may be given to initially adding a LTRA, rather than a LABA, to ICS when asthma symptoms are not adequately controlled by ICS alone. Furthermore, individualization of medication regimens, treatment of co-morbid conditions, and patient education are crucial to optimizing compliance with therapy, improving disease control, and reducing the risk of exacerbations. Lastly, the development of new asthma treatments, perhaps based upon personalized medicine, may revolutionize the future treatment of moderate asthma. PMID:22259262
The contribution of executive functions to emergent mathematic skills in preschool children.
Espy, Kimberly Andrews; McDiarmid, Melanie M; Cwik, Mary F; Stalets, Melissa Meade; Hamby, Arlena; Senn, Theresa E
2004-01-01
Mathematical ability is related to both activation of the prefrontal cortex in neuroimaging studies of adults and to executive functions in school-age children. The purpose of this study was to determine whether executive functions were related to emergent mathematical proficiency in preschool children. Preschool children (N = 96) were administered an executive function battery that was reduced empirically to working memory (WM), inhibitory control (IC), and shifting abilities by calculating composite scores derived from principal component analysis. Both WM and IC predicted early arithmetic competency, with the observed relations robust after controlling statistically for child age, maternal education, and child vocabulary. Only IC accounted for unique variance in mathematical skills, after the contribution of other executive functions were controlled statistically as well. Specific executive functions are related to emergent mathematical proficiency in this age range. Longitudinal studies using structural equation modeling are necessary to better characterize these ontogenetic relations.
Posterior insular cortex is necessary for conditioned inhibition of fear
Foilb, Allison R.; Flyer-Adams, Johanna G.; Maier, Steven F.; Christianson, John P.
2016-01-01
Veridical detection of safety versus danger is critical to survival. Learned signals for safety inhibit fear, and so when presented, reduce fear responses produced by danger signals. This phenomenon is termed conditioned inhibition of fear. Here, we report that CS+/CS− fear discrimination conditioning over 5 days in rats leads the CS− to become a conditioned inhibitor of fear, as measured by the classic tests of conditioned inhibition: summation and retardation of subsequent fear acquisition. We then show that NMDA-receptor antagonist AP5 injected to posterior insular cortex (IC) before training completely prevented the acquisition of a conditioned fear inhibitor, while intra-AP5 to anterior and medial IC had no effect. To determine if the IC contributes to the recall of learned fear inhibition, injections of the GABAA agonist muscimol were made to posterior IC before a summation test. This resulted in fear inhibition per se, which obscured inference to the effect of IC inactivation with recall of the safety cue. Control experiments sought to determine if the role of the IC in conditioned inhibition learning could be reduced to simpler fear discrimination function, but fear discrimination and recall were unaffected by AP5 or muscmiol, respectively, in the posterior IC. These data implicate a role of posterior IC in the learning of conditioned fear inhibitors. PMID:27523750
30 CFR 57.22102 - Smoking (I-C mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22102 Smoking (I-C mines). (a...
Gawthrop, Peter J.; Lakie, Martin; Loram, Ian D.
2017-01-01
Key points A human controlling an external system is described most easily and conventionally as linearly and continuously translating sensory input to motor output, with the inevitable output remnant, non‐linearly related to the input, attributed to sensorimotor noise.Recent experiments show sustained manual tracking involves repeated refractoriness (insensitivity to sensory information for a certain duration), with the temporary 200–500 ms periods of irresponsiveness to sensory input making the control process intrinsically non‐linear.This evidence calls for re‐examination of the extent to which random sensorimotor noise is required to explain the non‐linear remnant.This investigation of manual tracking shows how the full motor output (linear component and remnant) can be explained mechanistically by aperiodic sampling triggered by prediction error thresholds.Whereas broadband physiological noise is general to all processes, aperiodic sampling is associated with sensorimotor decision making within specific frontal, striatal and parietal networks; we conclude that manual tracking utilises such slow serial decision making pathways up to several times per second. Abstract The human operator is described adequately by linear translation of sensory input to motor output. Motor output also always includes a non‐linear remnant resulting from random sensorimotor noise from multiple sources, and non‐linear input transformations, for example thresholds or refractory periods. Recent evidence showed that manual tracking incurs substantial, serial, refractoriness (insensitivity to sensory information of 350 and 550 ms for 1st and 2nd order systems respectively). Our two questions are: (i) What are the comparative merits of explaining the non‐linear remnant using noise or non‐linear transformations? (ii) Can non‐linear transformations represent serial motor decision making within the sensorimotor feedback loop intrinsic to tracking? Twelve participants (instructed to act in three prescribed ways) manually controlled two systems (1st and 2nd order) subject to a periodic multi‐sine disturbance. Joystick power was analysed using three models, continuous‐linear‐control (CC), continuous‐linear‐control with calculated noise spectrum (CCN), and intermittent control with aperiodic sampling triggered by prediction error thresholds (IC). Unlike the linear mechanism, the intermittent control mechanism explained the majority of total power (linear and remnant) (77–87% vs. 8–48%, IC vs. CC). Between conditions, IC used thresholds and distributions of open loop intervals consistent with, respectively, instructions and previous measured, model independent values; whereas CCN required changes in noise spectrum deviating from broadband, signal dependent noise. We conclude that manual tracking uses open loop predictive control with aperiodic sampling. Because aperiodic sampling is inherent to serial decision making within previously identified, specific frontal, striatal and parietal networks we suggest that these structures are intimately involved in visuo‐manual tracking. PMID:28833126
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, J.; Mowrey, J.
1995-12-01
This report describes the design, development and testing of process controls for selected system operations in the Browns Ferry Nuclear Plant (BFNP) Reactor Water Cleanup System (RWCU) using a Computer Simulation Platform which simulates the RWCU System and the BFNP Integrated Computer System (ICS). This system was designed to demonstrate the feasibility of the soft control (video touch screen) of nuclear plant systems through an operator console. The BFNP Integrated Computer System, which has recently. been installed at BFNP Unit 2, was simulated to allow for operator control functions of the modeled RWCU system. The BFNP Unit 2 RWCU systemmore » was simulated using the RELAP5 Thermal/Hydraulic Simulation Model, which provided the steady-state and transient RWCU process variables and simulated the response of the system to control system inputs. Descriptions of the hardware and software developed are also included in this report. The testing and acceptance program and results are also detailed in this report. A discussion of potential installation of an actual RWCU process control system in BFNP Unit 2 is included. Finally, this report contains a section on industry issues associated with installation of process control systems in nuclear power plants.« less
Araya, Romina E.; Jury, Jennifer; Bondar, Constanza
2014-01-01
Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen. PMID:24915573
Araya, Romina E; Jury, Jennifer; Bondar, Constanza; Verdu, Elena F; Chirdo, Fernando G
2014-01-01
Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen.
Fan, Haitao; Zhang, Ian; Chen, Xuebo; Zhang, Leying; Wang, Huaqing; Fonseca, Anna Da; Manuel, Edwin R.; Diamond, Don J.; Raubitschek, Andrew; Badie, Behnam
2012-01-01
Purpose Recently, we showed that intratumoral delivery of low-dose, immunostimulatory CpG oligodeoxynucleotides conjugated with carbon nanotubes (CNT-CpG) was more effective than free CpG and not only eradicated intracranial (i.c.) gliomas, but also induced antitumor immunity that protected mice from subsequent i.c. or systemic tumor rechallenge. Here, we examined if the same “intracerebral immunotherapy” strategy could be applied to the treatment of metastatic brain tumors. Experimental Design Mice with both i.c. and subcutaneous (s.c.) melanomas were injected intratumorally with CNT-CpG into either location. Antitumor responses were assessed by flow cytometry, bioluminescent imaging, and animal survival. Results When given s.c., CNT-CpG response was mostly local, and it only modestly inhibited the growth of i.c. melanomas. However, i.c. CNT-CpG abrogated the growth of not only brain, but also s.c. tumors. Furthermore, compared to s.c. injections, i.c. CNT-CpG elicited a stronger inflammatory response that resulted in more potent antitumor cytotoxicity and improved in vivo trafficking of effector cells into both i.c. and s.c. tumors. To investigate factors that accounted for these observations, CNT-CpG biodistribution and cellular inflammatory responses were examined in both tumor locations. Intracranial melanomas retained the CNT-CpG particles longer and were infiltrated by TLR-9-positive microglia. In contrast, myeloid-derived suppressive cells were more abundant in s.c. tumors. Although depletion of these cells prior to s.c. CNT-CpG therapy enhanced its cytotoxic responses, antitumor responses to brain melanomas were unchanged. Conclusions These findings suggest that intracerebral CNT-CpG immunotherapy is more effective than systemic therapy in generating antitumor responses that target both brain and systemic melanomas. PMID:22904105
Fan, Haitao; Zhang, Ian; Chen, Xuebo; Zhang, Leying; Wang, Huaqing; Da Fonseca, Anna; Manuel, Edwin R; Diamond, Don J; Raubitschek, Andrew; Badie, Behnam
2012-10-15
Recently, we showed that intratumoral delivery of low-dose, immunostimulatory CpG oligodeoxynucleotides conjugated with carbon nanotubes (CNT-CpG) was more effective than free CpG and not only eradicated intracranial (i.c.) gliomas but also induced antitumor immunity that protected mice from subsequent i.c. or systemic tumor rechallenge. Here, we examined whether the same "intracerebral immunotherapy" strategy could be applied to the treatment of metastatic brain tumors. Mice with both i.c. and s.c. melanomas were injected intratumorally with CNT-CpG into either location. Antitumor responses were assessed by flow cytometry, bioluminescent imaging, and animal survival. When given s.c., CNT-CpG response was mostly local, and it only modestly inhibited the growth of i.c. melanomas. However, i.c. CNT-CpG abrogated the growth of not only brain but also s.c. tumors. Furthermore, compared with s.c. injections, i.c. CNT-CpG elicited a stronger inflammatory response that resulted in more potent antitumor cytotoxicity and improved in vivo trafficking of effector cells into both i.c. and s.c. tumors. To investigate factors that accounted for these observations, CNT-CpG biodistribution and cellular inflammatory responses were examined in both tumor locations. Intracranial melanomas retained the CNT-CpG particles longer and were infiltrated by Toll-like receptor (TLR-9)-positive microglia. In contrast, myeloid-derived suppressive cells were more abundant in s.c. tumors. Although depletion of these cells before s.c. CNT-CpG therapy enhanced its cytotoxic responses, antitumor responses to brain melanomas were unchanged. These findings suggest that intracerebral CNT-CpG immunotherapy is more effective than systemic therapy in generating antitumor responses that target both brain and systemic melanomas. ©2012 AACR
Chae, Sung-Wook; Kim, Young-Sung; Lee, Yong-Moo; Kim, Won-Kyung; Lee, Young-Kyoo; Kim, Su-Hwan
2015-02-01
This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.
Once more on the equilibrium-point hypothesis (lambda model) for motor control.
Feldman, A G
1986-03-01
The equilibrium control hypothesis (lambda model) is considered with special reference to the following concepts: (a) the length-force invariant characteristic (IC) of the muscle together with central and reflex systems subserving its activity; (b) the tonic stretch reflex threshold (lambda) as an independent measure of central commands descending to alpha and gamma motoneurons; (c) the equilibrium point, defined in terms of lambda, IC and static load characteristics, which is associated with the notion that posture and movement are controlled by a single mechanism; and (d) the muscle activation area (a reformulation of the "size principle")--the area of kinematic and command variables in which a rank-ordered recruitment of motor units takes place. The model is used for the interpretation of various motor phenomena, particularly electromyographic patterns. The stretch reflex in the lambda model has no mechanism to follow-up a certain muscle length prescribed by central commands. Rather, its task is to bring the system to an equilibrium, load-dependent position. Another currently popular version defines the equilibrium point concept in terms of alpha motoneuron activity alone (the alpha model). Although the model imitates (as does the lambda model) spring-like properties of motor performance, it nevertheless is inconsistent with a substantial data base on intact motor control. An analysis of alpha models, including their treatment of motor performance in deafferented animals, reveals that they suffer from grave shortcomings. It is concluded that parameterization of the stretch reflex is a basis for intact motor control. Muscle deafferentation impairs this graceful mechanism though it does not remove the possibility of movement.
Bousquet, Jean; Barnes, Neil; Gibbs, Michael; Gul, Nadeem; Tomkins, Susan A; Zhou, Xin; Cho, Young-Joo; Park, Hae-Sim; Busse, William; Zhong, Nanshan
2017-04-28
To analyse the efficacy of fluticasone propionate (FP) alone and combined with salmeterol (SAL) in achieving guideline-defined asthma control in Asian patients. A post hoc analysis of the GOAL study in which patients were stratified by prior-medication use into inhaled corticosteroid (ICS)-naïve (Stratum [S] 1), low-dose ICS (S2), and medium-dose ICS (S3), and randomised to receive FP/SAL or FP. Doses were stepped-up every 12 weeks until Totally Controlled asthma or maximum dose was reached (PhI) and then maintained until study end (PhII). The primary endpoint was the proportion of patients achieving Well-Controlled asthma during PhI. Additional endpoints included Total Control and adverse events. Asian and non-Asian patients were analysed separately. In Asian patients in PhI, 74% (n = 87/118) in S1 achieved Well-Controlled asthma with FP/SAL versus 74% (n = 89/121) with FP alone (p = 0.839); corresponding values were 76% (n = 81/107) versus 60% (n = 62/104; p = 0.005) in S2, and 58% (n = 59/102) versus 43% (n = 41/95; p = 0.015) in S3. More patients in all three strata achieved Totally Controlled asthma with FP/SAL versus FP alone. Control was achieved more rapidly and with lower ICS doses with FP/SAL versus FP. A high proportion of patients who achieved control during PhI maintained control during PhII. Similar trends were found in non-Asian patients. No new safety concerns were identified. A greater proportion of Asian patients (S2 and S3, for Well-Controlled; all strata, for Totally Controlled) achieved guideline-defined asthma control with FP/SAL versus FP alone. High proportions of Asian patients in S1 achieved Well-Controlled asthma in both treatment groups.
NASA Astrophysics Data System (ADS)
Grinev, Timur; Shapiro, Moshe; Brumer, Paul
2015-09-01
Coherent control of internal conversion (IC) between the first (S1) and second (S2) singlet excited electronic states in pyrazine, where the S2 state is populated from the ground singlet electronic state S0 by weak field excitation, is examined. Control is implemented by shaping the laser which excites S2. Excitation and IC are considered simultaneously, using the recently introduced resonance-based control approach. Highly successful control is achieved by optimizing both the amplitude and phase profiles of the laser spectrum. The dependence of control on the properties of resonances in S2 is demonstrated.
Chen, Yu-Pei; Tang, Ling-Long; Yang, Qi; Poh, Sharon-Shuxian; Hui, Edwin P; Chan, Anthony T C; Ong, Whee-Sze; Tan, Terence; Wee, Joseph; Li, Wen-Fei; Chen, Lei; Ma, Brigette B Y; Tong, Macy; Tan, Sze-Huey; Cheah, Shie-Lee; Fong, Kam-Weng; Sommat, Kiattisa; Soong, Yoke Lim; Guo, Ying; Lin, Ai-Hua; Sun, Ying; Hong, Ming-Huang; Cao, Su-Mei; Chen, Ming-Yuan; Ma, Jun
2018-04-15
Purpose: Because of the uneven geographic distribution and small number of randomized trials available, the value of additional induction chemotherapy (IC) to concurrent chemoradiotherapy (CCRT) in nasopharyngeal carcinoma (NPC) remains controversial. This study performed an individual patient data (IPD) pooled analysis to better assess the precise role of IC + CCRT in locoregionally advanced NPC. Experimental Design: Four randomized trials in endemic areas were identified, representing 1,193 patients; updated IPD were obtained. Progression-free survival (PFS) and overall survival (OS) were the primary and secondary endpoints, respectively. Results: Median follow-up was 5.0 years. The HR for PFS was 0.70 [95% confidence interval (CI), 0.56-0.86; P = 0.0009; 9.3% absolute benefit at 5 years] in favor of IC + CCRT versus CCRT alone. IC + CCRT also improved OS (HR = 0.75; 95% CI, 0.57-0.99; P = 0.04) and reduced distant failure (HR = 0.68; 95% CI, 0.51-0.90; P = 0.008). IC + CCRT had a tendency to improve locoregional control compared with CCRT alone (HR = 0.70; 95% CI, 0.48-1.01; P = 0.06). There was no heterogeneity between trials in any analysis. No interactions between patient characteristics and treatment effects on PFS or OS were found. After adding two supplementary trials to provide a more comprehensive overview, the conclusions remained valid and were strengthened. In a supplementary Bayesian network analysis, no statistically significant differences in survival between different IC regimens were detected. Conclusions: This IPD pooled analysis demonstrates the superiority of additional IC over CCRT alone in locoregionally advanced NPC, with the survival benefit mainly associated with improved distant control. Clin Cancer Res; 24(8); 1824-33. ©2018 AACR . ©2018 American Association for Cancer Research.
Jen, Rachel; Rennard, Stephen I; Sin, Don D
2012-01-01
Background: Chronic obstructive pulmonary disease (COPD) is characterized by chronic inflammation in the small airways. The effect of inhaled corticosteroids (ICS) on lung inflammation in COPD remains uncertain. We sought to determine the effects of ICS on inflammatory indices in bronchial biopsies and bronchoalveolar lavage fluid of patients with COPD. Methods: We searched Medline, Embase, Cinahl, and the Cochrane database for randomized, controlled clinical trials that used bronchial biopsies and bronchoalveolar lavage to evaluate the effects of ICS in stable COPD. For each chosen study, we calculated the mean differences in the concentrations of inflammatory cells before and after treatment in both intervention and control groups. These values were then converted into standardized mean differences (SMD) to accommodate the differences in patient selection, clinical treatment, and biochemical procedures that were employed across the original studies. If significant heterogeneity was present (P < 0.1), then a random effects model was used to pool the original data; otherwise, a fixed effects model was used. Results: We identified eight original studies that met the inclusion criteria. Four studies used bronchial biopsies (n =102 participants) and showed that ICS were effective in reducing CD4 and CD8 cell counts (SMD, −0.52 units and −0.66 units, 95% confidence interval). The five studies used bronchoalveolar lavage fluid (n =309), which together showed that ICS reduced neutrophil and lymphocyte counts (SMD, −0.64 units and −0.64 units, 95% confidence interval). ICS on the other hand significantly increased macrophage counts (SMD, 0.68 units, 95% confidence interval) in bronchoalveolar lavage fluid. Conclusion: ICS has important immunomodulatory effects in airways with COPD that may explain its beneficial effect on exacerbations and enhanced risk of pneumonia. PMID:23055709
Symptom-Based Controller Therapy: A New Paradigm for Asthma Management
Divekar, Rohit; Ameredes, Bill T.; Calhoun, William J.
2013-01-01
Appropriate management of persistent asthma, according to US and international guidelines, requires daily use of controller medications, most generally, inhaled corticosteroids (ICS). This approach, although effective and well established, imposes burdens of treatment and side effects onto asthma patients. A growing body of evidence suggests that patients with persistent asthma need not be managed with daily ICS, but rather can use them on an intermittent basis, occasioned by the occurrence of symptoms sufficient to warrant treatment with a rescue inhaler. Large, randomized, controlled studies, over a range of asthma severity, and in a range of ages from pediatrics to adults, suggest that in well-selected patients, a symptom based approach to administering controller therapy may produce equivalent outcomes, while reducing exposure to ICS. The concept of providing anti-inflammatory treatment to the patient, at the time inflammation is developing, is termed ‘temporal personalization’. The evidence to date suggests that symptom-based controller therapy is broadly useful in selected asthma patients, and is a management approach that could be incorporated into US and international guidelines for asthma. PMID:23904098
Seroprevalence and risk factors for Toxoplasma gondii infection on pig farms in central China.
Tao, Qing; Wang, Zhengsong; Feng, Huihui; Fang, Rui; Nie, Hao; Hu, Min; Zhou, Yanqin; Zhao, Junlong
2011-04-01
Toxoplasma gondii is a protozoan parasite that causes severe diseases in mammals, including humans, around the world. In China, pork is the main meat source; accordingly, T. gondii in pigs is considered an important source for human toxoplasmosis. Understanding the epidemiology of toxoplasmosis in pig farms is thus important for control of the disease in humans. The purpose of the present study was to investigate the epizootiology of T. gondii infections in pig farms in central China by assessing the seroprevalence and risk factors of this disease. In the present study, 3,558 sera samples were collected from pigs in 37 large-scale pig farms in this region and tested by AG-ELISA. The total seroprevalence was 24.5%, with the greatest prevalence in breeding pigs. The risk factors for toxoplasmosis suggest that high frequency of the contact of pigs with cats (P ≤ 0.01; IC 95%), high density of pig breeding (P ≤ 0.01; IC 95%), the presence of mosquitoes and flies (P ≤ 0.01; IC 95%), semi-patency pens (P ≤ 0.05; IC 95%), and low frequency of scavenging (P ≤ 0.01; IC 95%) were all associated with seroprevalence. In addition, the use of sulfonamides (P ≤ 0.01; IC 95%) significantly decreased seroprevalence. This is the first report of anti- T. gondii antibodies in pigs on large-scale pig farms in central China. The findings will provide useful information for designing control strategies of toxoplasmasis in pig farms.
Lopes-Virella, Maria F; Baker, Nathaniel L; Hunt, Kelly J; Lyons, Timothy J; Jenkins, Alicia J; Virella, Gabriel
2012-06-01
To determine whether immunocomplexes (ICs) containing advanced glycation end product (AGE)-LDL (AGE-LDL) and oxidized LDL (oxLDL) contribute to the development of retinopathy over a 16-year period in subjects with type 1 diabetes. Levels of AGE-LDL and oxLDL in ICs were measured in 517 patients of the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) cohort. Retinopathy was assessed by stereoscopic fundus photography. Cox proportional hazards models were used to assess the effect of AGE-LDL-ICs and oxLDL-ICs on retinopathy progression. In unadjusted models, higher baseline levels of AGE-LDL-ICs and oxLDL-ICs significantly predicted progression of diabetic retinopathy outcomes. After adjustment by study-design variables (treatment group, retinopathy cohort, duration of type 1 diabetes, and baseline albumin excretion rate [AER], hemoglobin A(1c) (HbA(1c)), and Early Treatment Diabetic Retinopathy Study [ETDRS] score), one SD increase in IC levels was associated with 47% (hazard ratio [HR] 1.47 [95% CI 1.19-1.81]; AGE-LDL-IC) and 45% (1.45 [1.17-1.80]; oxLDL-IC) increased risk of developing proliferative diabetic retinopathy (PDR) and 37% (1.37 [1.12-1.66]; to both ICs) increased risk of progressing to severe nonproliferative retinopathy. Analyses were stratified by retinopathy cohort because results differed between primary and secondary cohorts. For AGE-LDL-ICs, HR for progression to PDR was 2.38 (95% CI 1.30-4.34) in the primary cohort and attenuated in the secondary cohort (1.29 [1.03-1.62]). Similar results were observed for oxLDL-ICs. Increased levels of AGE-LDL and oxLDL in ICs are associated with increased risk for progression to advanced retinopathy in patients with type 1 diabetes, indicating that the antibody response to modified LDL plays a significant role in retinopathy progression.
Koch, M; Eriksson, H G; Axelsson, S; Tegelberg, A
2009-04-01
To survey the clinical endodontic protocols of general dental practitioners (GDPs) in public dental clinics and to assess the effect of an educational intervention on the adoption of a nickel-titanium (Ni-Ti) rotary system. General dental practitioners in a Swedish Intervention County (IC), underwent an educational programme in endodontics. A follow-up questionnaire was posted to 98 GDPs in the IC and to 97 GDPs in a Control County (CC), where no specific training had been provided. The questionnaire concerned demographics, clinical endodontic protocols and instrumentation techniques. The response rate to the questionnaire was 87%. More than 90% of all GDPs reported they always or generally used rubber dam, determined working length, used the canal irrigant 0.5% buffered NaOCl and calcium hydroxide as an interappointment dressing. Two of three GDPs reported, they generally or always informed the patient of the prognosis. Every second GDP reported routines for postoperative recall and follow-up. The Ni-Ti rotary technique was reported to be completely adopted by 77% of the GDPs in the IC, significantly higher than in the CC (6%), P < 0.001. In the IC 79% of the GDPs reported they completed instrumentation in one treatment session, compared with only 32% in the CC, P < 0.001. The 'single-cone' mode of canal filling was reported to be significantly more frequent amongst GDPs in the IC, P < 0.001. General dental practitioners in both counties reported using contemporary clinical endodontic protocols. GDPs who had undergone an educational programme in Ni-Ti rotary instrumentation reported they had successfully integrated the technique into daily clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, H.R.; Pechere, J.C.
1988-04-01
The effect of four macrolides against intracellular Toxoplasma gondii was determined in three different in vitro systems. Unactivated murine peritoneal macrophages were infected with the virulent RH strain of T. gondii. The activity of the macrolides was first measured with (/sup 3/H)uracil, which is incorporated by the parasite but not the host cell. The 50% inhibitory concentrations (IC50s) and 95% confidence limits were calculated at 54 (38 to 73), 140 (98 to 201), 147 (101 to 214), and 246 (187 to 325) micron for roxithromycin, azithromycin (CP-62,993), A-56268, and spiramycin, respectively. Inhibition of Toxoplasma growth was confirmed by microscopic examinationmore » of the infected macrophages after treatment with roxithromycin. Compared with untreated controls, roxithromycin concentrations near the IC50s decreased the number of infected cells, the number of tachyzoites per vacuole, and the number of cells containing rosettes (i.e., clusters of more than eight tachyzoites). After treatment with the four macrolides, tachyzoites were released from the macrophages and subcultured in HeLa cells, which are nonprofessional phagocytes, to assess the viability of the remaining parasites. This showed that the macrolides at concentrations corresponding to four times their 90% inhibitory concentrations (IC90s) had no significant killing effect. At 8 times the IC90, roxithromycin showed an incomplete killing effect, similar to that of the combination of pyrimethamine (0.41 microM)-sulfadiazine (99.42 microM). All macrolides tested showed inhibitory effects against intracellular T. gondii, but amounts of azithromycin and A-56268 corresponding to the IC90 appeared to be toxic against the host macrophages, which might have had nonspecific activity against Toxoplasma metabolism.« less
Evaluation of Acanthamoeba Myosin-IC as a Potential Therapeutic Target
Lorenzo-Morales, Jacob; López-Arencibia, Atteneri; Reyes-Batlle, María; Piñero, José E.; Valladares, Basilio; Maciver, Sutherland K.
2014-01-01
Members of the genus Acanthamoeba are facultative pathogens of humans, causing a sight-threatening keratitis and a fatal encephalitis. We have targeted myosin-IC by using small interfering RNA (siRNA) silencing as a therapeutic approach, since it is known that the function of this protein is vital for the amoeba. In this work, specific siRNAs against the Acanthamoeba myosin-IC gene were developed. Treated and control amoebae were cultured in growth and encystment media to evaluate the induced effects after myosin-IC gene knockdown, as we have anticipated that cyst formation may be impaired. The effects of myosin-IC gene silencing were inhibition of cyst formation, inhibition of completion of cytokinesis, inhibition of osmoregulation under osmotic stress conditions, and death of the amoebae. The finding that myosin-IC silencing caused incompletion of cytokinesis is in agreement with earlier suggestions that the protein plays a role in cell locomotion, which is necessary to pull daughter cells apart after mitosis in a process known as “traction-mediated cytokinesis”. We conclude that myosin-IC is a very promising potential drug target for the development of much-needed antiamoebal drugs and that it should be further exploited for Acanthamoeba therapy. PMID:24468784
Neuhaus, Jochen; Schulte-Baukloh, Heinrich; Stolzenburg, Jens-Uwe; Speroni di Fenizio, Pietro; Horn, Lars-Christian; Rüffert, Henrik; Hartenstein, Siegurd; Burger, Maximilian; Schulze, Matthias; Schwalenberg, Thilo
2012-10-01
Dysregulation of neurotransmitter receptors may contribute to bladder overactivity (OAB) symptoms. To address the question whether specific receptor expression patterns are associated with bladder pain syndrome/interstitial cystitis (BPS/IC), we examined the expression of muscarinic, purinergic and histamine receptors in the detrusor. Detrusor receptor expression was investigated in bladder biopsies of female BPS/IC patients (n = 44; age 60.64 ± 13.78, mean ± SD) and carcinoma patients (n = 11; age 58.91 ± 12.72) undergoing cystectomy. Protein expression of muscarinic (M2, M3), purinergic (P2X1-3) and histamine receptors (H1, H2) was analysed by confocal immunofluorescence, and gene expression was quantified by real-time polymerase chain reaction (qPCR). M2, P2X1, P2X2 and H1 receptor immunoreactivity (-IR) was significantly enhanced in BPS/IC compared to the control group, while there was no difference for M3-, P2X3- and H2-IR. We calculated a score, which separated BPS/IC from control patients with an AUC of 89.46%, showing 84.09% sensitivity and 90.91% specificity. Patients had a 9.25 times enhanced calculated risk for BPS/IC. In addition, two patient subgroups (M2 > M3 and M3 > M2) were observed, which differed in associated purinergic and histamine receptor expression. M2, P2X1, P2X2 and H1 were significantly upregulated in BPS/IC patients, and H2 was occasionally highly overexpressed. There was no significant correlation between receptor protein and gene expression, implying posttranslational mechanisms being responsible for the altered receptor expressions. On the basis of individual receptor profiles, upregulated receptors could be targeted by monotherapy or combination therapy with already approved receptor inhibitors, thereby promoting tailored therapy for patients suffering from BPS/IC-like symptoms.
30 CFR 57.22104 - Open flames (I-C mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
....22104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22104 Open flames (I-C...
Pang, Ran; Ali, Abdullah
2015-12-01
Management of interstitial cystitis/bladder pain syndrome (IC/BPS) remains a challenge due to poor understanding on its etiology. Complementary and alternative medicine (CAM), as an optional treatment, has been widely used, because no definitive conventional therapy is available. The different domain of CAM provides miscellaneous treatments for IC/BPS, which mainly include dietary modification, nutraceuticals, bladder training, biofeedback, yoga, massage, physical therapy, Qigong, traditional Chinese medicine and acupuncture. Clinical evidence has shown that each therapy can certainly benefit a portion of IC/BPS patients. However, the target patient group of each therapy has not been well studied and randomized, controlled trials are needed to further confirm the efficacy and reliability of CAM on managing IC/BPS. Despite these limitations, CAM therapeutic characteristics including non-invasive and effectiveness for specific patients allow clinicians and patients to realize multimodal and individualized therapy for IC/BPS.
Ali, Abdullah
2015-01-01
Management of interstitial cystitis/bladder pain syndrome (IC/BPS) remains a challenge due to poor understanding on its etiology. Complementary and alternative medicine (CAM), as an optional treatment, has been widely used, because no definitive conventional therapy is available. The different domain of CAM provides miscellaneous treatments for IC/BPS, which mainly include dietary modification, nutraceuticals, bladder training, biofeedback, yoga, massage, physical therapy, Qigong, traditional Chinese medicine and acupuncture. Clinical evidence has shown that each therapy can certainly benefit a portion of IC/BPS patients. However, the target patient group of each therapy has not been well studied and randomized, controlled trials are needed to further confirm the efficacy and reliability of CAM on managing IC/BPS. Despite these limitations, CAM therapeutic characteristics including non-invasive and effectiveness for specific patients allow clinicians and patients to realize multimodal and individualized therapy for IC/BPS. PMID:26816867
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donald D. Dudenhoeffer; Tuan Q. Tran; Ronald L. Boring
2006-08-01
The science of prognostics is analogous to a doctor who, based on a set of symptoms and patient tests, assesses a probable cause, the risk to the patient, and a course of action for recovery. While traditional prognostics research has focused on the aspect of hydraulic and mechanical systems and associated failures, this project will take a joint view in focusing not only on the digital I&C aspect of reliability and risk, but also on the risks associated with the human element. Model development will not only include an approximation of the control system physical degradation but also on humanmore » performance degradation. Thus the goal of the prognostic system is to evaluate control room operation; to identify and potentially take action when performance degradation reduces plant efficiency, reliability or safety.« less
Pires, Luís; Leitão, José; Guerrini, Chiara; Simões, Mário R
2017-07-03
Cognitive control allows information processing and behaviour to vary adaptively from moment to moment depending on current goals. Two of the most prominent theories that have been proposed to account for the processing of cognitive control are the Conflict Monitoring Theory (CMT) and the Prediction of Response-Outcome Theory (PRO). According to both theories, the implementation of cognitive control during a trial in a conflict task reflects processing events that occurred in the preceding trial. Both CMT and PRO advocate that the detection of conflict situations leads to the recruitment of cognitive control, but they differ regarding the processing underpinnings of cognitive control during conflict resolution. CMT proposes that conflict between alternative responses is resolved by enhancing the task's relevant dimension, reducing interference from the task's irrelevant dimension(s). This control setup promotes conflict adaptation in the subsequent trial. PRO proposes that conflict is resolved by means of a cost-effectiveness analysis that identifies and suppresses action plans linked to the less appropriate responses, facilitating conflict resolution in the subsequent trial. To adjudicate between these alternatives, we manipulated contingencies pertaining to two-trial sequences (n-1; n), namely, the congruency between task relevant/irrelevant dimensions in trial n-1 and response repetition in trial n. A spatial Stroop task was used, in which task-relevant and irrelevant information were integrated within the same stimulus. In this task, participants were required to attend to the direction of an arrow while ignoring its position. The arrow's direction and position could be congruent (C) or incongruent (IC). In one experiment, trials in which the participant was required to respond according to the position of a circle (PO; position only trials), occupying the sequential position n, were the focus of the analyses. Three experiments were conducted manipulating the trials' sequence structure. In Experiment 1, we studied a low control/low conflict condition (cC trials), and two high control/low conflict conditions (icC with and without response repetition). In Experiment 2, we studied two low control/no conflict conditions (cPO with and without response repetition) and two high control/no conflict conditions (icPO with and without response repetition). In Experiment 3, we studied a high control/high conflict condition (icIC) and two low control/high conflict conditions (cIC with and without response repetition). Overall, our findings are in agreement with previous studies in which both bottom-up processing, linked to response and stimulus position repetition, and top-down processing, linked to cognitive control, were shown to contribute to sequence effects in conflict tasks. Specifically, our observations mainly support PRO's account of conflict resolution, in which the intervention of top-down processing is substantially more complex than in CMT's account. Copyright © 2017 Elsevier B.V. All rights reserved.
Baker-Genaw, Kimberly; Kokas, Maria S; Ahsan, Syed F; Darnley-Fisch, Deborah; Drake, Sean; Goyal, Nikhil; Inamdar, Kedar; Moutzouros, Vasilios; Prabhakar, Deepak; Rolland, Laurie; Sangha, Roopina; Shreve, Maria; Woodward, Ann
2016-07-01
Little is known about residents' performance on the milestones at the institutional level. Our institution formed a work group to explore this using an institutional-level curriculum and residents' evaluation of the milestones. We assessed whether beginner-level milestones for interpersonal and communication skills (ICS) related to observable behaviors in ICS-focused objective structured clinical examinations (OSCEs) for postgraduate year (PGY) 1 residents across specialties. The work group compared ICS subcompetencies across 12 programs to identify common beginner-level physician-patient communication milestones. The selected ICS milestone sets were compared for common language with the ICS-OSCE assessment tool-the Kalamazoo Essential Elements of Communication Checklist-Adapted (KEECC-A). To assess whether OSCE scores related to ICS milestone scores, all PGY-1 residents from programs that were part of Next Accreditation System Phase 1 were identified; their OSCE scores from July 2013 to June 2014 and ICS subcompetency scores from December 2014 were compared. The milestones for 10 specialties and the transitional year had at least 1 ICS subcompetency that related to physician-patient communication. The language of the ICS beginner-level milestones appears similar to behaviors outlined in the KEECC-A. All 60 residents with complete data received at least a beginner-level ICS subcompetency score and at least a satisfactory score on all 3 OSCEs. The ICS-OSCE scores for PGY-1 residents appear to relate to beginner-level milestones for physician-patient communication across multiple specialties.
Adhesive Systems as an Alternative Material for Color Masking of White Spot Lesions: Do They Work?
de Lacerda, Ana Júlia Farias; da Silva Ávila, Daniele Mara; Borges, Alessandra Buhler; Pucci, Cesar Rogerio; Rocha Gomes Torres, Carlos
2016-01-01
To evaluate the color masking effect of infiltration treatment of artificial white spot lesions (AWSL) using a dedicated resin in comparison to different adhesive systems. Enamel/dentin specimens were obtained from bovine incisors and baseline color was assessed using a reflectance spectrophotometer, according to the CIE L*a*b* system. AWSL were produced using a buffered acid solution and a new color evaluation was performed. The specimens were divided into 8 groups: control: artificial saliva changed daily for 7 days; IC: infiltrating resin Icon; EC: EquiaCoat; FU: Futurabond U; SBU: Single Bond U; SBMP: Scotchbond MP; OB: OptibondFL; BF: Bioforty. After the treatments, the color was evaluated again and the values for the parameters ΔL (change in lightness), Δa (change in chroma), Δb (change in hue), and ΔE (general color difference) were calculated in relation to baseline. Data were analyzed by one-way ANOVA and Tukey's tests. After treatment, ANOVA showed significant differences for all parameters (p = 0.001). Tukey's test showed the greatest lightness reduction (ΔL) for the IC group, followed by EC, FU, and SBU. The SBMP, OB, and BF groups were similar to the control. For Δb values, all groups showed differences in relation to the control, with no differences between them. In relation to ΔE, all groups showed differences in relation to the control (ΔE = 5.24), with no significant differences between them. ΔE values after application of all resinous materials were lower than the threshold of 3.7, indicating effective color masking. The Icon infiltrant produced a greater lightness reduction of white lesions (ΔL). For general color difference (ΔE), all the resinous materials tested were able to color mask artificial AWSL.
Inhaled corticosteroids in children with persistent asthma: effects on growth.
Zhang, Linjie; Prietsch, Sílvio O M; Ducharme, Francine M
2014-07-17
Treatment guidelines for asthma recommend inhaled corticosteroids (ICS) as first-line therapy for children with persistent asthma. Although ICS treatment is generally considered safe in children, the potential systemic adverse effects related to regular use of these drugs have been and continue to be a matter of concern, especially the effects on linear growth. To assess the impact of ICS on the linear growth of children with persistent asthma and to explore potential effect modifiers such as characteristics of available treatments (molecule, dose, length of exposure, inhalation device) and of treated children (age, disease severity, compliance with treatment). We searched the Cochrane Airways Group Specialised Register of trials (CAGR), which is derived from systematic searches of bibliographic databases including CENTRAL, MEDLINE, EMBASE, CINAHL, AMED and PsycINFO; we handsearched respiratory journals and meeting abstracts. We also conducted a search of ClinicalTrials.gov and manufacturers' clinical trial databases to look for potential relevant unpublished studies. The literature search was conducted in January 2014. Parallel-group randomised controlled trials comparing daily use of ICS, delivered by any type of inhalation device for at least three months, versus placebo or non-steroidal drugs in children up to 18 years of age with persistent asthma. Two review authors independently performed study selection, data extraction and assessment of risk of bias in included studies. We conducted meta-analyses using the Cochrane statistical package RevMan 5.2 and Stata version 11.0. We used the random-effects model for meta-analyses. We used mean differences (MDs) and 95% CIs as the metrics for treatment effects. A negative value for MD indicates that ICS have suppressive effects on linear growth compared with controls. We performed a priori planned subgroup analyses to explore potential effect modifiers, such as ICS molecule, daily dose, inhalation device and age of the treated child. We included 25 trials involving 8471 (5128 ICS-treated and 3343 control) children with mild to moderate persistent asthma. Six molecules (beclomethasone dipropionate, budesonide, ciclesonide, flunisolide, fluticasone propionate and mometasone furoate) [corrected] given at low or medium daily doses were used during a period of three months to four to six years. Most trials were blinded and over half of the trials had drop out rates of over 20%.Compared with placebo or non-steroidal drugs, ICS produced a statistically significant reduction in linear growth velocity (14 trials with 5717 participants, MD -0.48 cm/y, 95% CI -0.65 to -0.30, moderate quality evidence) and in the change from baseline in height (15 trials with 3275 participants; MD -0.61 cm/y, 95% CI -0.83 to -0.38, moderate quality evidence) during a one-year treatment period.Subgroup analysis showed a statistically significant group difference between six molecules in the mean reduction of linear growth velocity during one-year treatment (Chi² = 26.1, degrees of freedom (df) = 5, P value < 0.0001). The group difference persisted even when analysis was restricted to the trials using doses equivalent to 200 μg/d hydrofluoroalkane (HFA)-beclomethasone. Subgroup analyses did not show a statistically significant impact of daily dose (low vs medium), inhalation device or participant age on the magnitude of ICS-induced suppression of linear growth velocity during a one-year treatment period. However, head-to-head comparisons are needed to assess the effects of different drug molecules, dose, inhalation device or patient age. No statistically significant difference in linear growth velocity was found between participants treated with ICS and controls during the second year of treatment (five trials with 3174 participants; MD -0.19 cm/y, 95% CI -0.48 to 0.11, P value 0.22). Of two trials that reported linear growth velocity in the third year of treatment, one trial involving 667 participants showed similar growth velocity between the budesonide and placebo groups (5.34 cm/y vs 5.34 cm/y), and another trial involving 1974 participants showed lower growth velocity in the budesonide group compared with the placebo group (MD -0.33 cm/y, 95% CI -0.52 to -0.14, P value 0.0005). Among four trials reporting data on linear growth after treatment cessation, three did not describe statistically significant catch-up growth in the ICS group two to four months after treatment cessation. One trial showed accelerated linear growth velocity in the fluticasone group at 12 months after treatment cessation, but there remained a statistically significant difference of 0.7 cm in height between the fluticasone and placebo groups at the end of the three-year trial.One trial with follow-up into adulthood showed that participants of prepubertal age treated with budesonide 400 μg/d for a mean duration of 4.3 years had a mean reduction of 1.20 cm (95% CI -1.90 to -0.50) in adult height compared with those treated with placebo. Regular use of ICS at low or medium daily doses is associated with a mean reduction of 0.48 cm/y in linear growth velocity and a 0.61-cm change from baseline in height during a one-year treatment period in children with mild to moderate persistent asthma. The effect size of ICS on linear growth velocity appears to be associated more strongly with the ICS molecule than with the device or dose (low to medium dose range). ICS-induced growth suppression seems to be maximal during the first year of therapy and less pronounced in subsequent years of treatment. However, additional studies are needed to better characterise the molecule dependency of growth suppression, particularly with newer molecules (mometasone, ciclesonide), to specify the respective role of molecule, daily dose, inhalation device and patient age on the effect size of ICS, and to define the growth suppression effect of ICS treatment over a period of several years in children with persistent asthma.
NASA Technical Reports Server (NTRS)
Fouts, Douglas J.
1992-01-01
The design, implementation, testing, and applications of a gallium-arsenide digital phase shifter and fan-out buffer are described. The integrated circuit provides a method for adjusting the phase of high-speed clock and control signals in digital systems, without the need for pruning cables, multiplexing between cables of different lengths, delay lines, or similar techniques. The phase of signals distributed with the described chip can be dynamically adjusted in eight different steps of approximately 60 ps per step. The IC also serves as a fan-out buffer and provides 12 in-phase outputs. The chip is useful for distributing high-speed clock and control signals in synchronous digital systems, especially if components are distributed over a large physical area or if there is a large number of components.
Tasdemir, Deniz; Sanabria, David; Lauinger, Ina L; Tarun, Alice; Herman, Rob; Perozzo, Remo; Zloh, Mire; Kappe, Stefan H; Brun, Reto; Carballeira, Néstor M
2010-11-01
Acetylenic fatty acids are known to display several biological activities, but their antimalarial activity has remained unexplored. In this study, we synthesized the 2-, 5-, 6-, and 9-hexadecynoic acids (HDAs) and evaluated their in vitro activity against erythrocytic (blood) stages of Plasmodium falciparum and liver stages of Plasmodium yoelii infections. Since the type II fatty acid biosynthesis pathway (PfFAS-II) has recently been shown to be indispensable for liver stage malaria parasites, the inhibitory potential of the HDAs against multiple P. falciparum FAS-II (PfFAS-II) elongation enzymes was also evaluated. The highest antiplasmodial activity against blood stages of P. falciparum was displayed by 5-HDA (IC(50) value 6.6 μg/ml), whereas the 2-HDA was the only acid arresting the growth of liver stage P. yoelii infection, in both flow cytometric assay (IC(50) value 2-HDA 15.3 μg/ml, control drug atovaquone 2.5 ng/ml) and immunofluorescence analysis (IC(50) 2-HDA 4.88 μg/ml, control drug atovaquone 0.37 ng/ml). 2-HDA showed the best inhibitory activity against the PfFAS-II enzymes PfFabI and PfFabZ with IC(50) values of 0.38 and 0.58 μg/ml (IC(50) control drugs 14 and 30 ng/ml), respectively. Enzyme kinetics and molecular modeling studies revealed valuable insights into the binding mechanism of 2-HDA on the target enzymes. All HDAs showed in vitro activity against Trypanosoma brucei rhodesiense (IC(50) values 3.7-31.7 μg/ml), Trypanosoma cruzi (only 2-HDA, IC(50) 20.2 μg/ml), and Leishmania donovani (IC(50) values 4.1-13.4 μg/ml) with generally low or no significant toxicity on mammalian cells. This is the first study to indicate therapeutic potential of HDAs against various parasitic protozoa. It also points out that the malarial liver stage growth inhibitory effect of the 2-HDA may be promoted via PfFAS-II enzymes. The lack of cytotoxicity, lipophilic nature, and calculated pharmacokinetic properties suggests that 2-HDA could be a useful compound to study the interaction of fatty acids with these key P. falciparum enzymes. Copyright © 2010 Elsevier Ltd. All rights reserved.
Tasdemir, Deniz; Sanabria, David; Lauinger, Ina L.; Tarun, Alice; Herman, Rob; Perozzo, Remo; Zloh, Mire; Kappe, Stefan H.; Brun, Reto; Carballeira, Néstor M.
2010-01-01
Acetylenic fatty acids are known to display several biological activities, but their antimalarial activity has remained unexplored. In this study, we synthesized the 2-, 5-, 6-, and 9-hexadecynoic acids (HDAs) and evaluated their in vitro activity against erythrocytic (blood) stages of Plasmodium falciparum and liver stages of P. yoelii infections. Since the type II fatty acid biosynthesis pathway (PfFAS-II) has recently been shown to be indispensable for liver stage malaria parasites, the inhibitory potential of the HDAs against multiple P. falciparum FAS-II (PfFAS-II) elongation enzymes was also evaluated. The highest antiplasmodial activity against blood stages of P. falciparum was displayed by 5-HDA (IC50 value 6.6. μg/ml), whereas the 2-HDA was the only acid arresting the growth of liver stage P. yoelii infection, in both flow cytometric assay (IC50 value 2-HDA 15.3 μg/ml, control drug atovaquone 2.5 ng/ml) and immunofluorescense analysis (IC50 2-HDA 4.88 μg/ml, control drug atovaquone 0.37 ng/ml). 2-HDA showed the best inhibitory against the PfFAS-II enzymes PfFabI and PfFabZ with IC50 values of 0.38 and 0.58 μg/ml (IC50 control drugs 14 and 30 ng/ml) respectively. Enzyme kinetics and molecular modeling studies revealed valuable insights into the binding mechanism of 2-HDA on the target enzymes. All HDAs showed in vitro activity against Trypanosoma brucei rhodesiense (IC50 values 3.7–31.7 μg/ml), Trypanosoma cruzi (only 2-HDA, IC50 20.2 μg/ml), and Leishmania donovani (IC50 values 4.1–13.4 μg/ml) with generally low or no significant toxicity on mammalian cells. This is the first study to indicate therapeutic potential of HDAs against various parasitic protozoa. It also points out that the malarial liver stage growth inhibitory effect of the 2-HDA may be promoted via PfFAS-II enzymes. The lack of cytotoxicity, lipophilic nature and calculated pharmacokinetic properties suggest that 2-HDA could be a useful compound to study the interaction of fatty acids with these key P. falciparum enzymes. PMID:20855214
Xerostomia relates to the degree of asthma control.
Alcázar Navarrete, Bernardino; Gómez-Moreno, Gerardo; Aguilar-Salvatierra, Antonio; Guardia, Javier; Romero Palacios, Pedro José
2015-04-01
Few studies have assessed the relationships between xerostomia and the use of inhaled corticosteroids (ICS). The main objective of this study was to investigate the prevalence of xerostomia in a respiratory outpatient clinic and its relationship with bronchial asthma and ICS use. A cross-sectional observational study of patients recruited in an outpatient setting divided them according to previous diagnoses of bronchial asthma. Data about pulmonary function, concomitant medication, medical comorbidities, Xerostomia Inventory test (XI test), and the degree of asthma control by ACT (asthma control test) were collected for each patient. A linear regression model was applied, using the XI score as dependent variable and the ACT score as independent variable. The 57 patients were divided into asthmatics (40 patients, 70.2%) and control group without asthma (17, 29.8%). The prevalence of xerostomia was 87.7% (50 patients), with no differences between the study groups or current dose of ICS. In the asthmatic group, patients with uncontrolled asthma had worse XI scores than those with partially or totally controlled asthma (30.43 ± 8.71 vs. 24.92 ± 8.08; P < 0.05). In a logistic regression model, the XI test was significantly associated to ACT scores with a moderately strong correlation (r = 0.55; P = 0.005) after adjusting for the current daily dose of ICS. Xerostomia is a common symptom in the ambulatory setting. There is a moderate relationship between the degree of asthma control and the severity of xerostomia. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Knapp, Caprice; Madden, Vanessa; Sloyer, Phyllis; Shenkman, Elizabeth
2012-04-01
To assess the effects of an Integrated Care System (ICS) on parent-reported quality of care and satisfaction for Children with Special Health Care Needs (CSHCN). In 2006 Florida reformed its Medicaid program in Broward and Duval counties. Children's Medical Services Network (CMSN) chose to participate in the reform and developed an ICS for CSHCN. The ICS ushered in several changes such as more prior approval requirements and closing of the provider network. Telephone surveys were conducted with CMSN parents whose children reside in the reform counties and parents whose children reside outside of the reform counties in 2006 and 2007 (n = 1,727). Results from multivariate quasi-experimental models show that one component of parent-report quality of care, customer service, increased. Following implementation of the ICS, customer service increased by 0.22 points. After implementation of the ICS, parent-reported quality and satisfaction were generally unaffected. Although significant increases were not seen in the majority of the quality and satisfaction domains, it is nonetheless encouraging that parents did not report negative experiences with the ICS. It is important to present these interim findings so that progress can be monitored and decision-makers can begin to consider if the program should be expanded statewide.
Toxicity evaluation and prediction of toxic chemicals on activated sludge system.
Cai, Bijing; Xie, Li; Yang, Dianhai; Arcangeli, Jean-Pierre
2010-05-15
The gaps of data for evaluating toxicity of new or overloaded organic chemicals on activated sludge system resulted in the requirements for methodology of toxicity estimation. In this study, 24 aromatic chemicals typically existed in the industrial wastewater were selected and classified into three groups of benzenes, phenols and anilines. Their toxicity on activated sludge was then investigated. Two indexes of IC(50-M) and IC(50-S) were determined respectively from the respiration rates of activated sludge with different toxicant concentration at mid-term (24h) and short-term (30min) time intervals. Experimental results showed that the group of benzenes was the most toxic, followed by the groups of phenols and anilines. The values of IC(50-M) of the tested chemicals were higher than those of IC(50-S). In addition, quantitative structure-activity relationships (QSARs) models developed from IC(50-M) were more stable and accurate than those of IC(50-S). The multiple linear models based on molecular descriptors and K(ow) presented better reliability than single linear models based on K(ow). Among these molecular descriptors, E(lumo) was the most important impact factor for evaluation of mid-term toxicity. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Rojko, Jennifer L; Evans, Mark G; Price, Shari A; Han, Bora; Waine, Gary; DeWitte, Mark; Haynes, Jill; Freimark, Bruce; Martin, Pauline; Raymond, James T; Evering, Winston; Rebelatto, Marlon C; Schenck, Emanuel; Horvath, Christopher
2014-06-01
Vascular inflammation, infusion reactions, glomerulopathies, and other potentially adverse effects may be observed in laboratory animals, including monkeys, on toxicity studies of therapeutic monoclonal antibodies and recombinant human protein drugs. Histopathologic and immunohistochemical (IHC) evaluation suggests these effects may be mediated by deposition of immune complexes (ICs) containing the drug, endogenous immunoglobulin, and/or complement components in the affected tissues. ICs may be observed in glomerulus, blood vessels, synovium, lung, liver, skin, eye, choroid plexus, or other tissues or bound to neutrophils, monocytes/macrophages, or platelets. IC deposition may activate complement, kinin, and/or coagulation/fibrinolytic pathways and result in a systemic proinflammatory response. IC clearance is biphasic in humans and monkeys (first from plasma to liver and/or spleen, second from liver or spleen). IC deposition/clearance is affected by IC composition, immunomodulation, and/or complement activation. Case studies are presented from toxicity study monkeys or rats and indicate IHC-IC deposition patterns similar to those predicted by experimental studies of IC-mediated reactions to heterologous protein administration to monkeys and other species. The IHC-staining patterns are consistent with findings associated with generalized and localized IC-associated pathology in humans. However, manifestations of immunogenicity in preclinical species are generally not considered predictive to humans. © 2014 by The Author(s).
Lead biosorption of probiotic bacteria: effects of the intestinal content from laying hens.
Xing, Sicheng; Wang, Jie; Liang, Juan Boo; Jahromi, Mohammad Faseleh; Zhu, Cui; Shokryazdan, Parisa; Laudadio, Vito; Tufarelli, Vincenzo; Liao, Xindi
2017-05-01
This study investigated the effects and the possible mechanisms of intestinal content (IC) from laying hens on in vitro lead (Pb 2+ ) biosorption of four probiotic bacterial strains (Bifidobacterium longum BB79, Lactobacillus paracasei Kgl6, Lactobacillus pentosus ITA23, and Lactobacillus acidipiscis ITA44). The total Pb 2+ removal capacity of the four probiotic strains, with and without capsule polysaccharides (CPSs), increased in the presence of IC compared to the control (without IC). SEM imaging revealed certain unidentified particles from the IC adhered on the surface of bacterial cells sorted out using flow cytometry. Follow-up experiment showed an overall trend of increase in the Pb 2+ removal capacity of the sorted bacteria, but statistically significant for L. pentosus ITA23 and B. longum BB79 after incubation with IC, particularly with the suspended solid portion of the IC. In addition, the Fourier transform infrared spectrophotometer data showed that functional groups such as C-H, O-H, C=O, and C-O-C which possibly associated with Pb 2+ binding were mainly presented in the suspended solid portion of IC. Putting the above together, we postulated that the enhanced Pb 2+ binding capacity the probiotic bacteria incubated in IC is due to the adherence of the yet to be identified particles which could much exist in suspended solid portion of IC containing negatively charged functional groups which bind with the positive Pb 2+ ions.
An RFID-based on-lens sensor system for long-term IOP monitoring.
Hsu, Shun-Hsi; Chiou, Jin-Chern; Liao, Yu-Te; Yang, Tzu-Sen; Kuei, Cheng-Kai; Wu, Tsung-Wei; Huang, Yu-Chieh
2015-01-01
In this paper, an RFID-based on-lens sensor system is proposed for noninvasive long-term intraocular pressure monitoring. The proposed sensor IC, fabricated in a 0.18um CMOS process, consists of capacitive sensor readout circuitry, RFID communication circuits, and digital processing units. The sensor IC is integrated with electroplating capacitive sensors and a receiving antenna on the contact lens. The sensor IC can be wirelessly powered, communicate with RFID compatible equipment, and perform IOP measurement using on-lens capacitive sensor continuously from a 2cm distance while the incident power from an RFID reader is 20 dBm. The proposed system is compatible to Gen2 RFID protocol, extending the flexibility and reducing the self-developed firmware efforts.
Gibb, Stuart W.; Wood, John W.; Fauzi, R.; Mantoura, C.
1995-01-01
The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH3) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH3 from aqueous sample under strongly alkaline (pH > 12, NaOH), chelated (EDTA) conditions into a recycled acidic acceptor stream. The acceptor is then injected onto an ion chromatograph where NH3 and the MAs are fully resolved as their cations and detected conductimetrically. A versatile PC interfaced control unit and data capture unit (DCU) are employed in series to direct the selonoid valve switching sequence, IC operation and collection of data. Automation, together with other modifications improved both linearily (R2 > 0.99 MAs 0-100 nM, NH3 0-1000 nM) and precision (<8%) of FIGD-IC at nanomolar concentrations, compared with the manual procedure. The system was successfully applied to the determination of MAs and NH3 in seawater and in trapped particulate and gaseous atmospheric samples during an oceanographic research cruise. PMID:18925047
1983-09-13
TASK Titan Systems, Inc. AREA & WORK UNIT NUMBEPS P.O. Box 12139 La Jolla, California 92037 5261D 11. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT...ICB:M 0. 00 STRATEGIC E:0MPE 1. FC5 SLBM 0. 00 * S.EA AED) I. ?: CARRIER BATTLE cORC’UF IC). 00 SURFACE COMBAT ANTS 4. 5 1 AIR SUFER I ORITY (LANDi EASED
Active Control of Complex Systems via Dynamic (Recurrent) Neural Networks
1992-05-30
course, to on-going changes brought about by learning processes. As research in neurodynamics proceeded, the concept of reverberatory information flows...Microstructure of Cognition . Vol. 1: Foundations, M.I.T. Press, Cambridge, Massachusetts, pp. 354-361, 1986. 100 I Schwarz, G., "Estimating the dimension of a...Continually Running Fully Recurrent Neural Networks, ICS Report 8805, Institute of Cognitive Science, University of California at San Diego, 1988. 10 II
NASA Technical Reports Server (NTRS)
2004-01-01
This cutaway illustration shows the Saturn V S-IC (first) stage with detailed callouts of the components. The S-IC Stage is 138 feet long and 33 feet in diameter, producing 7,500,000 pounds of thrust through five F-1 engines that are powered by liquid oxygen and kerosene. Four of the engines are mounted on an outer ring and gimbal for control purposes. The fifth engine is rigidly mounted in the center. When ignited, the roar produced by the five engines equals the sound of 8,000,000 hi-fi sets.
Enhanced Reverse Transcription-PCR Assay for Detection of Norovirus Genogroup I
Dreier, Jens; Störmer, Melanie; Mäde, Dietrich; Burkhardt, Sabine; Kleesiek, Knut
2006-01-01
We have developed a one-tube reverse transcription (RT)-PCR method using the real-time TaqMan PCR system for the detection of norovirus genogroup I (NV GGI). By introduction of a novel probe based on locked nucleic acid technology, we enhanced the sensitivity of the assay compared to those of conventional TaqMan probes. The sensitivity of the NV GGI RT-PCR was determined by probit analysis with defined RNA standards and quantified norovirus isolates to 711 copies/ml (95% detection limit). In order to detect PCR inhibition, we included a heterologous internal control (IC) system based on phage MS2. This internally controlled RT-PCR was tested on different real-time PCR platforms, LightCycler, Rotorgene, Mastercycler EP realplex, and ABI Prism. Compared to the assay without an IC, the duplex RT-PCR exhibited no reduction in sensitivity in clinical samples. In combination with an established NV GGII real-time RT-PCR, we used the novel assay in a routine assay for diagnosis of clinical and food-borne norovirus infection. We applied this novel assay to analyze outbreaks of nonbacterial acute gastroenteritis. Norovirus of GGI was detected in these outbreaks. Sequence and similarity plot analysis of open reading frame 1 (ORF1) and ORF2 showed two genotypes, GGI/2 and GGI/4, in semiclosed communities. PMID:16891482
Physicians' preference for controller medication in mild persistent asthma.
Bakirtas, Arzu; Kutlu, Ali; Baccioglu, Ayse; Erkekol, Ferda Oner; Bavbek, Sevim; Kalayci, Omer
2017-10-01
Although the asthma guidelines recommend inhaled corticosteroids(ICS) or leukotriene receptor antagonists-(LTRAs) for the treatment of mild persistent asthma, factors governing the physicians' preference are unknown. We aimed to investigate the preference of physicians for the controller medication and the factors governing their choice. A self-administered questionnaire composed of 16 questions that aimed to determine the preference of the physicians for the first choice controller medication in mild persistent asthma and physician and patient related factors that may be associated with this selection was e-mailed to the members of the Turkish National Society of Allergy and Clinical Immunology and distributed to participants in the 21st congress. Of the 670 questionnaires, there were 51% participants and 336 of them were complete enough to be included in the analysis. Low dose ICS was preferred as the first choice controller medication for mild persistent asthma by 84.5% of the physicians. The reasons for physicians' preference were different for ICS and LTRA. In the logistic regression analysis, use of asthma guidelines (OR:3.5, 95%CI:1.3-9.3, p = 0.01), alignment in guidelines (OR:2.9, 95%CI:1.4-5.8, p = 0.002) and the opinion that it is a more effective (OR:2.3, 95%CI:1.1-4.8, p = 0.02) were independently associated with ICS preference. Being a pediatrician (OR:5.4, 95%CI: 2.7-10.5, p < 0.001) and the opinion that it has better patient compliance (OR:4.4, 95%CI: 1.6-12.0, p = 0.004) were independently associated with LTRA preference. Surveyed Turkish physicians, the majority of whom were specialists, preferred ICS over LTRA as controller medication in mild persistent asthma. Asthma guidelines, training background (pediatrician versus not) and perceived efficacy and patient compliance appeared to influence their preferences. Copyright © 2017. Published by Elsevier Ltd.
Koenig, Steven M; Murray, John J; Wolfe, James; Andersen, Leslie; Yancey, Steve; Prillaman, Barbara; Stauffer, John; Dorinsky, Paul
2008-05-01
Little is known about the use of biomarkers in guiding treatment decisions in routine asthma management. The objective of this study was to determine whether adding a LABA to an ICS would control bronchial hyperresponsiveness (BHR) at an overall lower dose of ICS when titration of medication was based upon the assessment of routine clinical measures with or without the measurement of BHR. After a 2-week run-in period, subjects (> or = 12 years) were randomized to one of three treatment groups. Two groups followed a BHR treatment strategy (based on clinical parameters [lung function, asthma symptoms, and bronchodilator use] and BHR) and were treated with either fluticasone propionate/salmeterol (FSC(BHR) group) or fluticasone propionate (FP(BHR) group) (n=156 each). The third group followed a clinical treatment algorithm (based on clinical parameters alone) and were treated with fluticasone propionate (FP(REF) group; n=154). All treatments were administered via Diskus. Treatment doses were adjusted as needed every 8 weeks for 40 weeks according to the subject's derived severity class, which was based on clinical measures of asthma control with or without BHR. The mean total daily inhaled corticosteroids (ICS) dose during the double-blind treatment period was lower, although not statistically significant, in the FSC(BHR) group compared with the FP(BHR) group (a difference of -42.9 mcg; p=0.07). Compared with the FP(REF) group, the mean total daily ICS dose was higher in the FSC(BHR) group (a difference of 85.2 mcg) and was significantly higher in the FP(BHR) group (a difference of 131.2 mcg, p=0.037). This study demonstrated that for most subjects, control of BHR was maintained when treatment was directed toward control of clinical parameters. In addition, there was a trend towards control of BHR and clinical measures at a lower dose of ICS when used concurrently with salmeterol.
Weil, Brian R.; Suzuki, Gen; Leiker, Merced M.; Fallavollita, James A.; Canty, John M.
2015-01-01
Rationale Allogeneic bone marrow-derived mesenchymal stem cells (MSCs) and cardiosphere-derived cells (CDCs) have each entered clinical trials but a direct comparison of these cell types has not been performed in a large animal model of hibernating myocardium. Objective Using completely blinded methodology, compare the efficacy of global intracoronary allogeneic MSCs (icMSCs, ~35×106) and CDCs (icCDCs, ~35×106) vs. vehicle in cyclosporine-immunosuppressed swine with a chronic LAD stenosis (n=26). Methods and Results Studies began 3-months after instrumentation when wall-thickening (%WT) was reduced (LAD%WT 38±11% (mean ± SD) vs. 83±26% in remote, p<0.01) and similar among groups. Four-weeks after treatment, LAD%WT increased similarly following icCDCs and icMSCs, while it remained depressed in vehicle-treated controls (icMSCs: 51±13%; icCDCs: 51±17%; vehicle: 34±3%, treatments p<0.05 vs. vehicle). There was no change in myocardial perfusion. Both icMSCs and icCDCs increased LAD myocyte nuclear density (icMSCs: 1601±279 nuclei/mm2, icCDCs: 1569±294 nuclei/mm2, vehicle: 973±181 nuclei/mm2, treatments p<0.05 vs. vehicle) and reduced myocyte diameter (icMSCs: 16.4±1.5 μm, icCDCs: 16.8±1.2 μm, vehicle: 20.2±3.7 μm, treatments p<0.05 vs. vehicle) to the same extent. Similar changes in myocyte nuclear density and diameter were observed in the remote region of cell-treated animals. Cell fate analysis using Y-FISH demonstrated rare cells from sex-mismatched donors. Conclusions Allogeneic icMSCs and icCDCs exhibit comparable therapeutic efficacy in a large animal model of hibernating myocardium. Both cell types produced equivalent increases in regional function and stimulated myocyte regeneration in ischemic and remote myocardium. The activation of endogenous myocyte proliferation and regression of myocyte cellular hypertrophy support a common mechanism of cardiac repair. PMID:26271689
A low-power RFID integrated circuits for intelligent healthcare systems.
Lee, Shuenn-Yuh; Wang, Liang-Hung; Fang, Qiang
2010-11-01
This paper presents low-power radio-frequency identification (RFID) technology for intelligent healthcare systems. With attention to power-efficient communication in the body sensor network, RF power transfer was estimated and the required low-power ICs, which are important in the development of a healthcare system with miniaturization and system integration, are discussed based on the RFID platform. To analyze the power transformation, this paper adopts a 915-MHz industrial, scientific, and medical RF with a radiation power of 70 mW to estimate the power loss under the 1-m communication distance between an RFID reader (bioinformation node) and a transponder (biosignal acquisition nodes). The low-power ICs of the transponder will be implemented in the TSMC 0.18-μm CMOS process. The simulation result reveals that the transponder's IC can fit in with the link budget of the UHF RFID system.
Posterior insular cortex is necessary for conditioned inhibition of fear.
Foilb, Allison R; Flyer-Adams, Johanna G; Maier, Steven F; Christianson, John P
2016-10-01
Veridical detection of safety versus danger is critical to survival. Learned signals for safety inhibit fear, and so when presented, reduce fear responses produced by danger signals. This phenomenon is termed conditioned inhibition of fear. Here, we report that CS+/CS- fear discrimination conditioning over 5 days in rats leads the CS- to become a conditioned inhibitor of fear, as measured by the classic tests of conditioned inhibition: summation and retardation of subsequent fear acquisition. We then show that NMDA-receptor antagonist AP5 injected to posterior insular cortex (IC) before training completely prevented the acquisition of a conditioned fear inhibitor, while intra-AP5 to anterior and medial IC had no effect. To determine if the IC contributes to the recall of learned fear inhibition, injections of the GABAA agonist muscimol were made to posterior IC before a summation test. This resulted in fear inhibition per se, which obscured inference to the effect of IC inactivation with recall of the safety cue. Control experiments sought to determine if the role of the IC in conditioned inhibition learning could be reduced to simpler fear discrimination function, but fear discrimination and recall were unaffected by AP5 or muscimol, respectively, in the posterior IC. These data implicate a role of posterior IC in the learning of conditioned fear inhibitors. Copyright © 2016 Elsevier Inc. All rights reserved.
In vitro inhibition of CYP3A4 by herbal remedies frequently used by cancer patients.
Engdal, Silje; Nilsen, Odd Georg
2009-07-01
The herbal remedies Natto K2, Agaricus, mistletoe, noni juice, green tea and garlic, frequently used by cancer patients, were investigated for their in vitro inhibition potential of cytochrome P-450 3A4 (CYP3A4) metabolism. To our knowledge, only garlic and green tea had available data on the possible inhibition of CYP3A4 metabolism. Metabolic studies were performed with human c-DNA baculovirus expressed CYP3A4. Testosterone was used as a substrate and ketoconazole as a positive quantitative inhibition control. The formation of 6-beta-OH-testosterone was quantified by a validated HPLC methodology. Green tea was the most potent inhibitor of CYP3A4 metabolism (IC(50): 73 microg/mL), followed by Agaricus, mistletoe and noni juice (1324, 3594, >10 000 microg/mL, respectively). All IC(50) values were high compared with those determined for crude extracts of other herbal remedies. The IC(50)/IC(25) ratios for the inhibiting herbal remedies ranged from 2.15 to 2.67, indicating similar inhibition profiles of the herbal inhibitors of CYP3A4. Garlic and Natto K2 were classified as non-inhibitors. Although Agaricus, noni juice, mistletoe and green tea inhibited CYP3A4 metabolism in vitro, clinically relevant systemic or intestinal interactions with CYP3A4 were considered unlikely, except for a probable inhibition of intestinal CYP3A4 by the green tea product. Copyright 2009 John Wiley & Sons, Ltd.
Rashid, Khwaja Aftab; Foster, C Stephen; Ahmed, A Razzaque
2013-11-19
To identify the epitopes on human β4 integrin to which the sera of patients with ocular cicatricial pemphigoid (OCP) and mucous membrane pemphigoid (MMP) without ocular involvement bind. Fragments of the intracellular domain of the β4 molecule were cloned, expressed, purified and peptides were synthesized. Antibodies to various fragments and peptides were produced in rabbits. Binding specificity was determined via Western blot and blocking experiments. Test sera and controls were injected into neonatal BALB/c mice for in vivo passive transfer. Sera from patients with OCP, MMP, and both OCP and MMP were bound to cloned fragments of IC3.0. Its subcloned fragments IC3.4 (1489 aa-1572 aa) and IC3.4.1 (1489 aa-1510 aa) were bound with the sera from patients with OCP only. Subcloned fragments IC3.6 (1573 aa-1822 aa) and IC3.6.1 (1689 aa-1702 aa) were bound with MMP sera only. No cross-reactivity in binding was observed. Immuno-affinity-purified sera from patients with OCP, MMP, and rabbit antibodies to IC3.0, IC3.4, IC3.4.1, IC3.6, and IC3.6.1, when injected in neonatal BALB/c mice, produced subepidermal blisters in their skin. These preliminary observations identified IC3.4.1 as the possible epitope for the binding of OCP auto-antibody and IC3.6.1 as the possible epitope for the binding of MMP auto-antibody without ocular disease. Antibodies specific to these peptides produced blisters when injected in mice. Still-unidentified epitopes may exist. These observations may enhance our understanding of the role of β4 integrin in the pathobiology of OCP and MMP. Early diagnosis may be possible if serologic tests with specificity and sensitivity can be developed.
Ni, Songshi; Fu, Zhenxue; Zhao, Jing; Liu, Hua
2014-07-01
Studies have indicated that therapy with inhaled corticosteroids (ICS) can be associated with a higher risk of pneumonia. However, it is not known whether ICS increases the risk of mycobacterium. Most of these published studies were small, and the conclusions were inconsistent. A meta-analysis was conducted into whether ICS increases the risk of mycobacterium in patients with chronic respiratory diseases. PubMed, OVID, EMBASE and Cochrane Library databases were searched. Five studies involving 4,851 cases and 28,477 controls were considered in the meta-analysis. From the pooled analyses, there was significant association between ICS and risk of mycobacterium in all patients with chronic respiratory diseases [risk ratio (RR) =1.81; 95% confidence interval (CI), 1.23-2.68; P=0.003]. Among patients with chronic respiratory diseases, the relationship between ICS and risk of tuberculosis (TB) was also significant (RR =1.34; 95% CI, 1.15-1.55; P=0.0001). And meta-analysis of four studies in patients with chronic obstructive pulmonary disease (COPD) (RR =1.42; 95% CI, 1.18-1.72; P=0.0003) or two studies in patients who have prior pulmonary TB (RR =1.61; 95% CI, 1.35-1.92; P<0.00001) or three studies in patients with high-dose ICS (RR =1.60; 95% CI, 1.28-1.99; P<0.0001) showed a relationship between ICS and risk of mycobacterium. Significant relationship has been shown between ICS use and risk of mycobacterium in all patients with chronic respiratory diseases. ICS use also increases the risk of TB among the patients with chronic respiratory diseases. Use of ICS increases the risk of mycobacterium in patients with COPD or patients with prior pulmonary TB or patients inhaling high-dose corticosteroids. Further research is required to establish the potential adverse effect of ICS as a therapy for chronic respiratory diseases.
Brant, Jason O; Riva, Alberto; Resnick, James L; Yang, Thomas P
2014-01-01
Reduced representation bisulfite sequencing (RRBS) was used to analyze DNA methylation patterns across the mouse brain genome in mice carrying a deletion of the Prader-Willi syndrome imprinting center (PWS-IC) on either the maternally- or paternally-inherited chromosome. Within the ∼3.7 Mb imprinted Angelman/Prader-Willi syndrome (AS/PWS) domain, 254 CpG sites were interrogated for changes in methylation due to PWS-IC deletion. Paternally-inherited deletion of the PWS-IC increased methylation levels ∼2-fold at each CpG site (compared to wild-type controls) at differentially methylated regions (DMRs) associated with 5′ CpG island promoters of paternally-expressed genes; these methylation changes extended, to a variable degree, into the adjacent CpG island shores. Maternal PWS-IC deletion yielded little or no changes in methylation at these DMRs, and methylation of CpG sites outside of promoter DMRs also was unchanged upon maternal or paternal PWS-IC deletion. Using stringent ascertainment criteria, ∼750,000 additional CpG sites were also interrogated across the entire mouse genome. This analysis identified 26 loci outside of the imprinted AS/PWS domain showing altered DNA methylation levels of ≥25% upon PWS-IC deletion. Curiously, altered methylation at 9 of these loci was a consequence of maternal PWS-IC deletion (maternal PWS-IC deletion by itself is not known to be associated with a phenotype in either humans or mice), and 10 of these loci exhibited the same changes in methylation irrespective of the parental origin of the PWS-IC deletion. These results suggest that the PWS-IC may affect DNA methylation at these loci by directly interacting with them, or may affect methylation at these loci through indirect downstream effects due to PWS-IC deletion. They further suggest the PWS-IC may have a previously uncharacterized function outside of the imprinted AS/PWS domain. PMID:25482058
Brant, Jason O; Riva, Alberto; Resnick, James L; Yang, Thomas P
2014-11-01
Reduced representation bisulfite sequencing (RRBS) was used to analyze DNA methylation patterns across the mouse brain genome in mice carrying a deletion of the Prader-Willi syndrome imprinting center (PWS-IC) on either the maternally- or paternally-inherited chromosome. Within the ~3.7 Mb imprinted Angelman/Prader-Willi syndrome (AS/PWS) domain, 254 CpG sites were interrogated for changes in methylation due to PWS-IC deletion. Paternally-inherited deletion of the PWS-IC increased methylation levels ~2-fold at each CpG site (compared to wild-type controls) at differentially methylated regions (DMRs) associated with 5' CpG island promoters of paternally-expressed genes; these methylation changes extended, to a variable degree, into the adjacent CpG island shores. Maternal PWS-IC deletion yielded little or no changes in methylation at these DMRs, and methylation of CpG sites outside of promoter DMRs also was unchanged upon maternal or paternal PWS-IC deletion. Using stringent ascertainment criteria, ~750,000 additional CpG sites were also interrogated across the entire mouse genome. This analysis identified 26 loci outside of the imprinted AS/PWS domain showing altered DNA methylation levels of ≥25% upon PWS-IC deletion. Curiously, altered methylation at 9 of these loci was a consequence of maternal PWS-IC deletion (maternal PWS-IC deletion by itself is not known to be associated with a phenotype in either humans or mice), and 10 of these loci exhibited the same changes in methylation irrespective of the parental origin of the PWS-IC deletion. These results suggest that the PWS-IC may affect DNA methylation at these loci by directly interacting with them, or may affect methylation at these loci through indirect downstream effects due to PWS-IC deletion. They further suggest the PWS-IC may have a previously uncharacterized function outside of the imprinted AS/PWS domain.
Inhibitory Effects of Respiration Inhibitors on Aflatoxin Production
Sakuda, Shohei; Prabowo, Diyan Febri; Takagi, Keiko; Shiomi, Kazuro; Mori, Mihoko; Ōmura, Satoshi; Nagasawa, Hiromichi
2014-01-01
Aflatoxin production inhibitors, which do not inhibit the growth of aflatoxigenic fungi, may be used to control aflatoxin without incurring a rapid spread of resistant strains. A respiration inhibitor that inhibits aflatoxin production was identified during a screening process for natural, aflatoxin-production inhibitors. This prompted us to evaluate respiration inhibitors as potential aflatoxin control agents. The inhibitory activities of four natural inhibitors, seven synthetic miticides, and nine synthetic fungicides were evaluated on aflatoxin production in Aspergillus parasiticus. All of the natural inhibitors (rotenone, siccanin, aptenin A5, and antimycin A) inhibited fungal aflatoxin production with IC50 values around 10 µM. Among the synthetic miticides, pyridaben, fluacrypyrim, and tolfenpyrad exhibited strong inhibitory activities with IC50 values less than 0.2 µM, whereas cyflumetofen did not show significant inhibitory activity. Of the synthetic fungicides, boscalid, pyribencarb, azoxystrobin, pyraclostrobin, and kresoxim-methyl demonstrated strong inhibitory activities, with IC50 values less than 0.5 µM. Fungal growth was not significantly affected by any of the inhibitors tested at concentrations used. There was no correlation observed between the targets of respiration inhibitors (complexes I, II, and III) and their IC50 values for aflatoxin-production inhibitory activity. This study suggests that respiration inhibitors, including commonly used pesticides, are useful for aflatoxin control. PMID:24674936
Chavan, Camille F; Mouthon, Michael; Draganski, Bogdan; van der Zwaag, Wietske; Spierer, Lucas
2015-07-01
Ample evidence indicates that inhibitory control (IC), a key executive component referring to the ability to suppress cognitive or motor processes, relies on a right-lateralized fronto-basal brain network. However, whether and how IC can be improved with training and the underlying neuroplastic mechanisms remains largely unresolved. We used functional and structural magnetic resonance imaging to measure the effects of 2 weeks of training with a Go/NoGo task specifically designed to improve frontal top-down IC mechanisms. The training-induced behavioral improvements were accompanied by a decrease in neural activity to inhibition trials within the right pars opercularis and triangularis, and in the left pars orbitalis of the inferior frontal gyri. Analyses of changes in brain anatomy induced by the IC training revealed increases in grey matter volume in the right pars orbitalis and modulations of white matter microstructure in the right pars triangularis. The task-specificity of the effects of training was confirmed by an absence of change in neural activity to a control working memory task. Our combined anatomical and functional findings indicate that differential patterns of functional and structural plasticity between and within inferior frontal gyri enhanced the speed of top-down inhibition processes and in turn IC proficiency. The results suggest that training-based interventions might help overcoming the anatomic and functional deficits of inferior frontal gyri manifesting in inhibition-related clinical conditions. More generally, we demonstrate how multimodal neuroimaging investigations of training-induced neuroplasticity enable revealing novel anatomo-functional dissociations within frontal executive brain networks. © 2015 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-10
... them by May 10, 2010. ADDRESSES: Send your comments on the IC to Hope Grey, Information Collection... (mail); or hope_ grey@fws.gov (e-mail). FOR FURTHER INFORMATION CONTACT: To request additional information about this IC, contact Hope Grey by mail or e- [[Page 11193
Auditory Attentional Set-Shifting and Inhibition in Children Who Stutter
ERIC Educational Resources Information Center
Eggers, Kurt; Jansson-Verkasalo, Eira
2017-01-01
Purpose: The purpose of this study was to investigate whether previously reported parental questionnaire-based differences in attentional shifting and inhibitory control (AS and IC; Eggers, De Nil, & Van den Bergh, 2010) would be supported by direct measurement of AS and IC using a computer task. Method: Participants were 16 Finnish children…
Inhibitory Control as a Moderator of Threat-related Interference Biases in Social Anxiety
Gorlin, Eugenia I.; Teachman, Bethany A.
2014-01-01
Prior findings are mixed regarding the presence and direction of threat-related interference biases in social anxiety. The current study examined general inhibitory control (IC), measured by the classic color-word Stroop, as a moderator of the relationship between both threat interference biases (indexed by the emotional Stroop) and several social anxiety indicators. High socially anxious undergraduate students (N=159) completed the emotional and color-word Stroop tasks, followed by an anxiety-inducing speech task. Participants completed measures of trait social anxiety, state anxiety before and during the speech, negative task-interfering cognitions during the speech, and overall self-evaluation of speech performance. Speech duration was used to measure behavioral avoidance. In line with hypotheses, IC moderated the relationship between emotional Stroop bias and every anxiety indicator (with the exception of behavioral avoidance), such that greater social-threat interference was associated with higher anxiety among those with weak IC, whereas lesser social-threat interference was associated with higher anxiety among those with strong IC. Implications for the theory and treatment of threat interference biases in socially anxious individuals are discussed. PMID:24967719
Coppedê, Abílio Ricciardi; Bersani, Edmilson; de Mattos, Maria da Gloria Chiarello; Rodrigues, Renata Cristina Silveira; Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria
2009-01-01
The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments.
Chronic ethanol increases systemic TLR3 agonist-induced neuroinflammation and neurodegeneration
2012-01-01
Background Increasing evidence links systemic inflammation to neuroinflammation and neurodegeneration. We previously found that systemic endotoxin, a TLR4 agonist or TNFα, increased blood TNFα that entered the brain activating microglia and persistent neuroinflammation. Further, we found that models of ethanol binge drinking sensitized blood and brain proinflammatory responses. We hypothesized that blood cytokines contribute to the magnitude of neuroinflammation and that ethanol primes proinflammatory responses. Here, we investigate the effects of chronic ethanol on neuroinflammation and neurodegeneration triggered by toll-like receptor 3 (TLR3) agonist poly I:C. Methods Polyinosine-polycytidylic acid (poly I:C) was used to induce inflammatory responses when sensitized with D-galactosamine (D-GalN). Male C57BL/6 mice were treated with water or ethanol (5 g/kg/day, i.g., 10 days) or poly I:C (250 μg/kg, i.p.) alone or sequentially 24 hours after ethanol exposure. Cytokines, chemokines, microglial morphology, NADPH oxidase (NOX), reactive oxygen species (ROS), high-mobility group box 1 (HMGB1), TLR3 and cell death markers were examined using real-time PCR, ELISA, immunohistochemistry and hydroethidine histochemistry. Results Poly I:C increased blood and brain TNFα that peaked at three hours. Blood levels returned within one day, whereas brain levels remained elevated for at least three days. Escalating blood and brain proinflammatory responses were found with ethanol, poly I:C, and ethanol-poly I:C treatment. Ethanol pretreatment potentiated poly I:C-induced brain TNFα (345%), IL-1β (331%), IL-6 (255%), and MCP-1(190%). Increased levels of brain cytokines coincided with increased microglial activation, NOX gp91phox, superoxide and markers of neurodegeneration (activated caspase-3 and Fluoro-Jade B). Ethanol potentiation of poly I:C was associated with ethanol-increased expression of TLR3 and endogenous agonist HMGB1 in the brain. Minocycline and naltrexone blocked microglial activation and neurodegeneration. Conclusions Chronic ethanol potentiates poly I:C blood and brain proinflammatory responses. Poly I:C neuroinflammation persists after systemic responses subside. Increases in blood TNFα, IL-1β, IL-6, and MCP-1 parallel brain responses consistent with blood cytokines contributing to the magnitude of neuroinflammation. Ethanol potentiation of TLR3 agonist responses is consistent with priming microglia-monocytes and increased NOX, ROS, HMGB1-TLR3 and markers of neurodegeneration. These studies indicate that TLR3 agonists increase blood cytokines that contribute to neurodegeneration and that ethanol binge drinking potentiates these responses. PMID:22709825
Okeno, Tobias O; Magothe, Thomas M; Kahi, Alexander K; Peters, Kurt J
2013-01-01
A bio-economic model was developed to evaluate the utilisation of indigenous chickens (IC) under different production systems accounting for the risk attitude of the farmers. The model classified the production systems into three categories based on the level of management: free-range system (FRS), where chickens were left to scavenge for feed resources with no supplementation and healthcare; intensive system (IS), where the chickens were permanently confined and supplied with rationed feed and healthcare; and semi-intensive system (SIS), a hybrid of FRS and IS, where the chickens were partially confined, supplemented with rationed feeds, provided with healthcare and allowed to scavenge within the homestead or in runs. The model allows prediction of the live weights and feed intake at different stages in the life cycle of the IC and can compute the profitability of each production system using both traditional and risk-rated profit models. The input parameters used in the model represent a typical IC production system in developing countries but are flexible and therefore can be modified to suit specific situations and simulate profitability and costs of other poultry species production systems. The model has the capability to derive the economic values as changes in the genetic merit of the biological parameter results in marginal changes in profitability and costs of the production systems. The results suggested that utilisation of IC in their current genetic merit and production environment is more profitable under FRS and SIS but not economically viable under IS.
NASA Astrophysics Data System (ADS)
Colins, Karen; Li, Liqian; Liu, Yu
2017-05-01
Mass production of widely used semiconductor digital integrated circuits (ICs) has lowered unit costs to the level of ordinary daily consumables of a few dollars. It is therefore reasonable to contemplate the idea of an engineered system that consumes unshielded low-cost ICs for the purpose of measuring gamma radiation dose. Underlying the idea is the premise of a measurable correlation between an observable property of ICs and radiation dose. Accumulation of radiation-damage-induced state changes or error events is such a property. If correct, the premise could make possible low-cost wide-area radiation dose measurement systems, instantiated as wireless sensor networks (WSNs) with unshielded consumable ICs as nodes, communicating error events to a remote base station. The premise has been investigated quantitatively for the first time in laboratory experiments and related analyses performed at the Canadian Nuclear Laboratories. State changes or error events were recorded in real time during irradiation of samples of ICs of different types in a 60Co gamma cell. From the error-event sequences, empirical distribution functions of dose were generated. The distribution functions were inverted and probabilities scaled by total error events, to yield plots of the relationship between dose and error tallies. Positive correlation was observed, and discrete functional dependence of dose quantiles on error tallies was measured, demonstrating the correctness of the premise. The idea of an engineered system that consumes unshielded low-cost ICs in a WSN, for the purpose of measuring gamma radiation dose over wide areas, is therefore tenable.
CARMENES instrument control system and operational scheduler
NASA Astrophysics Data System (ADS)
Garcia-Piquer, Alvaro; Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Gesa, Lluis; Morales, Juan Carlos; Pérez-Calpena, Ana; Seifert, Walter; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, José A.; Reiners, Ansgar
2014-07-01
The main goal of the CARMENES instrument is to perform high-accuracy measurements of stellar radial velocities (1m/s) with long-term stability. CARMENES will be installed in 2015 at the 3.5 m telescope in the Calar Alto Observatory (Spain) and it will be equipped with two spectrographs covering from the visible to the near-infrared. It will make use of its near-IR capabilities to observe late-type stars, whose peak of the spectral energy distribution falls in the relevant wavelength interval. The technology needed to develop this instrument represents a challenge at all levels. We present two software packages that play a key role in the control layer for an efficient operation of the instrument: the Instrument Control System (ICS) and the Operational Scheduler. The coordination and management of CARMENES is handled by the ICS, which is responsible for carrying out the operations of the different subsystems providing a tool to operate the instrument in an integrated manner from low to high user interaction level. The ICS interacts with the following subsystems: the near-IR and visible channels, composed by the detectors and exposure meters; the calibration units; the environment sensors; the front-end electronics; the acquisition and guiding module; the interfaces with telescope and dome; and, finally, the software subsystems for operational scheduling of tasks, data processing, and data archiving. We describe the ICS software design, which implements the CARMENES operational design and is planned to be integrated in the instrument by the end of 2014. The CARMENES operational scheduler is the second key element in the control layer described in this contribution. It is the main actor in the translation of the survey strategy into a detailed schedule for the achievement of the optimization goals. The scheduler is based on Artificial Intelligence techniques and computes the survey planning by combining the static constraints that are known a priori (i.e., target visibility, sky background, required time sampling coverage) and the dynamic change of the system conditions (i.e., weather, system conditions). Off-line and on-line strategies are integrated into a single tool for a suitable transfer of the target prioritization made by the science team to the real-time schedule that will be used by the instrument operators. A suitable solution will be expected to increase the efficiency of telescope operations, which will represent an important benefit in terms of scientific return and operational costs. We present the operational scheduling tool designed for CARMENES, which is based on two algorithms combining a global and a local search: Genetic Algorithms and Hill Climbing astronomy-based heuristics, respectively. The algorithm explores a large amount of potential solutions from the vast search space and is able to identify the most efficient ones. A planning solution is considered efficient when it optimizes the objectives defined, which, in our case, are related to the reduction of the time that the telescope is not in use and the maximization of the scientific return, measured in terms of the time coverage of each target in the survey. We present the results obtained using different test cases.
Muluneh, Melaku
2015-01-01
In recent years there has been great progress harnessing the small-feature size and programmability of integrated circuits (ICs) for biological applications, by building microfluidics directly on top of ICs. However, a major hurdle to the further development of this technology is the inherent size-mismatch between ICs (~mm) and microfluidic chips (~cm). Increasing the area of the ICs to match the size of the microfluidic chip, as has often been done in previous studies, leads to a waste of valuable space on the IC and an increase in fabrication cost (>100×). To address this challenge, we have developed a three dimensional PDMS chip that can straddle multiple length scales of hybrid IC/microfluidic chips. This approach allows millimeter-scale ICs, with no post-processing, to be integrated into a centimeter-sized PDMS chip. To fabricate this PDMS chip we use a combination of soft-lithography and laser micromachining. Soft lithography was used to define micrometer-scale fluid channels directly on the surface of the IC, allowing fluid to be controlled with high accuracy and brought into close proximity to sensors for highly sensitive measurements. Laser micromachining was used to create ~50 μm vias to connect these molded PDMS channels to a larger PDMS chip, which can connect multiple ICs and house fluid connections to the outside world. To demonstrate the utility of this approach, we built and demonstrated an in-flow magnetic cytometer that consisted of a 5 × 5 cm2 microfluidic chip that incorporated a commercial 565 × 1145 μm2 IC with a GMR sensing circuit. We additionally demonstrated the modularity of this approach by building a chip that incorporated two of these GMR chips connected in series. PMID:25284502
Kitchen, Levi; Lawrence, Matthew; Speicher, Matthew; Frumkin, Kenneth
2016-01-01
Introduction Unilateral leg swelling with suspicion of deep venous thrombosis (DVT) is a common emergency department (ED) presentation. Proximal DVT (thrombus in the popliteal or femoral veins) can usually be diagnosed and treated at the initial ED encounter. When proximal DVT has been ruled out, isolated calf-vein deep venous thrombosis (IC-DVT) often remains a consideration. The current standard for the diagnosis of IC-DVT is whole-leg vascular duplex ultrasonography (WLUS), a test that is unavailable in many hospitals outside normal business hours. When WLUS is not available from the ED, recommendations for managing suspected IC-DVT vary. The objectives of the study is to use current evidence and recommendations to (1) propose a diagnostic algorithm for IC-DVT when definitive testing (WLUS) is unavailable; and (2) summarize the controversy surrounding IC-DVT treatment. Discussion The Figure combines D-dimer testing with serial CUS or a single deferred FLUS for the diagnosis of IC-DVT. Such an algorithm has the potential to safely direct the management of suspected IC-DVT when definitive testing is unavailable. Whether or not to treat diagnosed IC-DVT remains widely debated and awaiting further evidence. Conclusion When IC-DVT is not ruled out in the ED, the suggested algorithm, although not prospectively validated by a controlled study, offers an approach to diagnosis that is consistent with current data and recommendations. When IC-DVT is diagnosed, current references suggest that a decision between anticoagulation and continued follow-up outpatient testing can be based on shared decision-making. The risks of proximal progression and life-threatening embolization should be balanced against the generally more benign natural history of such thrombi, and an individual patient’s risk factors for both thrombus propagation and complications of anticoagulation. PMID:27429688
Kitchen, Levi; Lawrence, Matthew; Speicher, Matthew; Frumkin, Kenneth
2016-07-01
Unilateral leg swelling with suspicion of deep venous thrombosis (DVT) is a common emergency department (ED) presentation. Proximal DVT (thrombus in the popliteal or femoral veins) can usually be diagnosed and treated at the initial ED encounter. When proximal DVT has been ruled out, isolated calf-vein deep venous thrombosis (IC-DVT) often remains a consideration. The current standard for the diagnosis of IC-DVT is whole-leg vascular duplex ultrasonography (WLUS), a test that is unavailable in many hospitals outside normal business hours. When WLUS is not available from the ED, recommendations for managing suspected IC-DVT vary. The objectives of the study is to use current evidence and recommendations to (1) propose a diagnostic algorithm for IC-DVT when definitive testing (WLUS) is unavailable; and (2) summarize the controversy surrounding IC-DVT treatment. The Figure combines D-dimer testing with serial CUS or a single deferred FLUS for the diagnosis of IC-DVT. Such an algorithm has the potential to safely direct the management of suspected IC-DVT when definitive testing is unavailable. Whether or not to treat diagnosed IC-DVT remains widely debated and awaiting further evidence. When IC-DVT is not ruled out in the ED, the suggested algorithm, although not prospectively validated by a controlled study, offers an approach to diagnosis that is consistent with current data and recommendations. When IC-DVT is diagnosed, current references suggest that a decision between anticoagulation and continued follow-up outpatient testing can be based on shared decision-making. The risks of proximal progression and life-threatening embolization should be balanced against the generally more benign natural history of such thrombi, and an individual patient's risk factors for both thrombus propagation and complications of anticoagulation.
Muluneh, Melaku; Issadore, David
2014-12-07
In recent years there has been great progress harnessing the small-feature size and programmability of integrated circuits (ICs) for biological applications, by building microfluidics directly on top of ICs. However, a major hurdle to the further development of this technology is the inherent size-mismatch between ICs (~mm) and microfluidic chips (~cm). Increasing the area of the ICs to match the size of the microfluidic chip, as has often been done in previous studies, leads to a waste of valuable space on the IC and an increase in fabrication cost (>100×). To address this challenge, we have developed a three dimensional PDMS chip that can straddle multiple length scales of hybrid IC/microfluidic chips. This approach allows millimeter-scale ICs, with no post-processing, to be integrated into a centimeter-sized PDMS chip. To fabricate this PDMS chip we use a combination of soft-lithography and laser micromachining. Soft lithography was used to define micrometer-scale fluid channels directly on the surface of the IC, allowing fluid to be controlled with high accuracy and brought into close proximity to sensors for highly sensitive measurements. Laser micromachining was used to create ~50 μm vias to connect these molded PDMS channels to a larger PDMS chip, which can connect multiple ICs and house fluid connections to the outside world. To demonstrate the utility of this approach, we built and demonstrated an in-flow magnetic cytometer that consisted of a 5 × 5 cm(2) microfluidic chip that incorporated a commercial 565 × 1145 μm(2) IC with a GMR sensing circuit. We additionally demonstrated the modularity of this approach by building a chip that incorporated two of these GMR chips connected in series.
Ramos, Jose Tomas; Villar, Sonia; Bouza, Emilio; Bergon-Sendin, Elena; Perez Rivilla, Alfredo; Collados, Caridad Tapia; Andreu, Mariano; Reyes, Candelaria Santana; Campos-Herrero, María Isolina; de Heredia, Jon López; Herrera, María Cruz López; Alonso, Paloma Anguita; Pallás-Alonso, Carmen Rosa
2017-01-01
ABSTRACT An epidemiological, multicenter, noninterventional, observational case-control study was conducted to describe the performance of serum beta-d-glucan (BDG) and Candida PCR in blood, serum, and sterile samples for the diagnosis of invasive candidiasis (IC) in very-low-birth-weight (VLBW) preterm neonates and to compare these techniques with culture of samples from blood and other sterile sites. Seventeen centers participated in the study, and the number of episodes analyzed was 159. A total of 9 episodes of IC from 9 patients (7 confirmed and 2 probable) and 150 episodes of suspected sepsis from 117 controls were identified. The prevalence of IC was 5.7% (95% confidence interval [95% CI], 2.1 to 9.3). The mortality was significantly higher in episodes of IC (44.4%) than in the non-IC episodes (11.1%, P < 0.01). The sensitivity and specificity of the PCR performed on blood/serum samples were 87.5% and 81.6%, respectively. The sensitivity and specificity of the BDG results were lower (75.0% and 64.6%). For cases with negative culture results, the PCR and the BDG results were positive in 27 (17.4%) and 52 (33.5%) episodes, respectively. The presence of multiorgan failure, improvement with empirical antifungal therapy, thrombocytopenia, and Candida colonization were significantly associated (P < 0.01) with PCR or BDG positivity regardless of the results of the cultures. Serum BDG analysis and Candida PCR could be used as complementary diagnostic techniques to detect IC in VLBW neonates. PMID:28659321
Fuel Cell System Contaminants Material Screening Data: Text Version |
explore the results of fuel cell system contaminants studies. Total Anions [IC] and Total Concentration of Elements [ICP] in Leachate Solutions Material Class Manufacturer Trade Name and Use Grade ICP Total (ppm ) IC Total (ppm) Total Organic Carbon (ppm) Solution Conductivity (µS/cm) Adhesives LORD 2-part
A Development of Automatic Audit System for Written Informed Consent using Machine Learning.
Yamada, Hitomi; Takemura, Tadamasa; Asai, Takahiro; Okamoto, Kazuya; Kuroda, Tomohiro; Kuwata, Shigeki
2015-01-01
In Japan, most of all the university and advanced hospitals have implemented both electronic order entry systems and electronic charting. In addition, all medical records are subjected to inspector audit for quality assurance. The record of informed consent (IC) is very important as this provides evidence of consent from the patient or patient's family and health care provider. Therefore, we developed an automatic audit system for a hospital information system (HIS) that is able to evaluate IC automatically using machine learning.
Helguera, P R; Taborda, R; Docampo, D M; Ducasse, D A
2001-06-01
A detection system based on nested PCR after IC-RT-PCR (IC-RT-PCR-Nested PCR) was developed to improve indexing of Prunus necrotic ringspot virus in peach trees. Inhibitory effects and inconsistencies of the standard IC-RT-PCR were overcome by this approach. IC-RT-PCR-Nested PCR improved detection by three orders of magnitude compared with DAS-ELISA for the detection of PNRSV in leaves. Several different tissues were evaluated and equally consistent results were observed. The main advantages of the method are its consistency, high sensitivity and easy application in quarantine programs.
2014-01-01
Background Despite scientific advances in typing of C. difficile strains very little is known about how hospital staff use typing results during periods of increased incidence (PIIs). This qualitative study, undertaken alongside a randomised controlled trial (RCT), explored this issue. The trial compared ribotyping versus more rapid genotyping (MLVA or multilocus variable repeat analysis) and found no significant difference in post 48 hour cases (C difficile transmissions). Methods In-depth qualitative interviews with senior staff in 11/16 hospital trusts in the trial (5 MLVA and 6 Ribotyping). Semi-structured interviews were conducted at end of the trial period. Transcripts were content analysed using framework analysis supported by NVivo-8 software. Common sub-themes were extracted by two researchers independently. These were compared and organised into over-arching categories or ‘super-ordinate themes’. Results The trial recorded that 45% of typing tests had some impact on infection control (IC) activities. Interviews indicated that tests had little impact on initial IC decisions. These were driven by hospital protocols and automatically triggered when a PII was identified. To influence decision-making, a laboratory turnaround time < 3 days (ideally 24 hours) was suggested; MLVA turnaround time was 5.3 days. Typing results were predominantly used to modify initiated IC activities such as ward cleaning, audits of practice or staff training; major decisions (e.g. ward closure) were unaffected. Organisational factors could limit utilisation of MLVA results. Results were twice as likely to be reported as ‘aiding management’ (indirect benefit) than impacting on IC activities (direct effect). Some interviewees considered test results provided reassurance about earlier IC decisions; others identified secondary benefits on organisational culture. An underlying benefit of improved discrimination provided by MLVA typing was the ability to explore epidemiology associated with CDI cases in a hospital more thoroughly. Conclusions Ribotyping and MLVA are both valued by users. MLVA had little additional direct impact on initial infection control decisions. This would require reduced turnaround time. The major impact is adjustments to earlier IC measures and retrospective reassurance. For this, turnaround time is less important than discriminatory power. The potential remains for wider use of genotyping to examine transmission routes. PMID:24656142
Independent component analysis of DTI data reveals white matter covariances in Alzheimer's disease
NASA Astrophysics Data System (ADS)
Ouyang, Xin; Sun, Xiaoyu; Guo, Ting; Sun, Qiaoyue; Chen, Kewei; Yao, Li; Wu, Xia; Guo, Xiaojuan
2014-03-01
Alzheimer's disease (AD) is a progressive neurodegenerative disease with the clinical symptom of the continuous deterioration of cognitive and memory functions. Multiple diffusion tensor imaging (DTI) indices such as fractional anisotropy (FA) and mean diffusivity (MD) can successfully explain the white matter damages in AD patients. However, most studies focused on the univariate measures (voxel-based analysis) to examine the differences between AD patients and normal controls (NCs). In this investigation, we applied a multivariate independent component analysis (ICA) to investigate the white matter covariances based on FA measurement from DTI data in 35 AD patients and 45 NCs from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database. We found that six independent components (ICs) showed significant FA reductions in white matter covariances in AD compared with NC, including the genu and splenium of corpus callosum (IC-1 and IC-2), middle temporal gyral of temporal lobe (IC-3), sub-gyral of frontal lobe (IC-4 and IC-5) and sub-gyral of parietal lobe (IC-6). Our findings revealed covariant white matter loss in AD patients and suggest that the unsupervised data-driven ICA method is effective to explore the changes of FA in AD. This study assists us in understanding the mechanism of white matter covariant reductions in the development of AD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Richard Thomas; Ewing, Paul D.
The U.S. Nuclear Regulatory Commission’s (NRC’s) regulations in Part 50, “Domestic Licensing of Production and Utilization Facilities,” of Title 10 of the Code of Federal Regulations (10 CFR Part 50) state that structures, systems, and components important to safety in a nuclear power plant are to be designed to accommodate the effects of environmental conditions (i.e., remain functional under all postulated service conditions) and that design control measures such as testing are to be used to check the adequacy of design. Regulatory Guide (RG) 1.180 was developed to provide guidance to licensees and applicants on methods acceptable to the NRCmore » staff for complying with the NRC’s regulations on design, installation, and testing practices for addressing the effects of electromagnetic and radio-frequency interference (EMI/RFI) and power surges on safety-related instrumentation and control (I&C) systems. The first revision of RG 1.180 was issued in January 2000 and a second revision was issued in October 2003*. The second revision differed from the first revision in endorsing Military Standard (MIL-STD)-461E and the International Electrotechnical Commission (IEC) Standard (Std) 61000 series of EMI/RFI test methods, extending the guidance to cover signal line testing, incorporating frequency ranges where portable communications devices are experiencing increasing use, and relaxing the operating envelopes (test levels) when experience and confirmatory research warranted. It also offered exemptions from specific test criteria based on technical considerations such as plant conditions and the intended location of the safety-related I&C equipment. Since the last revision, new requirements have been identified, associated RGs have been created and updated, and additional industry guidance has been developed. Additionally, the operational environment has changed with the increase in wireless communication technology for both personal (smartphone) and industrial (remote I&C) purposes. Also, specific concerns and issues with testing methods and methodologies have been identified that must be addressed. Further, most of the standards that serve as the basis for the RG have been revised. Therefore, the NRC’s Office of Regulatory Research has contracted with Oak Ridge National Laboratory (ORNL) to incorporate new information and resolve the identified issues under NRC-HQ-60-14-D-0015, “Update to RG 1.180, Revision 2, Guidelines for Evaluating Electromagnetic and Radio-Frequency Interference in Safety-Related Instrumentation and Control Systems.” The ultimate goal of this project is to provide NRC the technical basis for developing and publishing a new revision of the RG. The focus of Task 4 was for ORNL to identify and address any new or additional EMI/RFI issues that could potentially impact the EMC of I&C systems. More specifically, ORNL was to evaluate the impact of any new issue on safety equipment in their local environments and then determine whether the issues should be included and discussed in the revision to RG 1.180 that is currently under way.« less
Gao, Zhouzheng; Zhang, Hongping; Ge, Maorong; Niu, Xiaoji; Shen, Wenbin; Wickert, Jens; Schuh, Harald
2015-03-10
The continuity and reliability of precise GNSS positioning can be seriously limited by severe user observation environments. The Inertial Navigation System (INS) can overcome such drawbacks, but its performance is clearly restricted by INS sensor errors over time. Accordingly, the tightly coupled integration of GPS and INS can overcome the disadvantages of each individual system and together form a new navigation system with a higher accuracy, reliability and availability. Recently, ionosphere-constrained (IC) precise point positioning (PPP) utilizing raw GPS observations was proven able to improve both the convergence and positioning accuracy of the conventional PPP using ionosphere-free combined observations (LC-PPP). In this paper, a new mode of tightly coupled integration, in which the IC-PPP instead of LC-PPP is employed, is implemented to further improve the performance of the coupled system. We present the detailed mathematical model and the related algorithm of the new integration of IC-PPP and INS. To evaluate the performance of the new tightly coupled integration, data of both airborne and vehicle experiments with a geodetic GPS receiver and tactical grade inertial measurement unit are processed and the results are analyzed. The statistics show that the new approach can further improve the positioning accuracy compared with both IC-PPP and the tightly coupled integration of the conventional PPP and INS.
Cheng, H W; Jeng, B M; Chen, C Y; Huang, H Y; Chiou, J C; Luo, C H
2013-01-01
This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18 um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.
De Vleesschauwer, David; Chernin, Leonid; Höfte, Monica M
2009-01-01
Background Induced resistance is a state of enhanced defensive capacity developed by a plant reacting to specific biotic or chemical stimuli. Over the years, several forms of induced resistance have been characterized, including systemic acquired resistance, which is induced upon localized infection by an avirulent necrotizing pathogen, and induced systemic resistance (ISR), which is elicited by selected strains of nonpathogenic rhizobacteria. However, contrary to the relative wealth of information on inducible defense responses in dicotyledoneous plants, our understanding of the molecular mechanisms underlying induced resistance phenomena in cereal crops is still in its infancy. Using a combined cytomolecular and pharmacological approach, we analyzed the host defense mechanisms associated with the establishment of ISR in rice by the rhizobacterium Serratia plymuthica IC1270. Results In a standardized soil-based assay, root treatment with IC1270 rendered foliar tissues more resistant to the hemibiotrophic pathogen Magnaporthe oryzae, causal agent of the devastating rice blast disease. Analysis of the cytological and biochemical alterations associated with restriction of fungal growth in IC1270-induced plants revealed that IC1270 primes rice for enhanced attacker-induced accumulation of reactive oxygen species (ROS) and autofluorescent phenolic compounds in and near epidermal cells displaying dense cytoplasmic granulation. Similar, yet more abundant, phenotypes of hypersensitively dying cells in the vicinity of fungal hyphae were evident in a gene-for-gene interaction with an avirulent M. oryzae strain, suggesting that IC1270-inducible ISR and R protein conditioned effector-triggered immunity (ETI) target similar defense mechanisms. Yet, this IC1270-inducible ISR response seems to act as a double-edged sword within the rice defense network as induced plants displayed an increased vulnerability to the necrotrophic pathogens Rhizoctonia solani and Cochliobolus miyabeanus. Artificial enhancement of ROS levels in inoculated leaves faithfully mimicked the opposite effects of IC1270 bacteria on aforementioned pathogens, suggesting a central role for oxidative events in the IC1270-induced resistance mechanism. Conclusion Besides identifying ROS as modulators of antagonistic defense mechanisms in rice, this work reveals the mechanistic similarities between S. plymuthica-mediated ISR and R protein-dictated ETI and underscores the importance of using appropriate innate defense mechanisms when breeding for broad-spectrum rice disease resistance. PMID:19161601
De Vleesschauwer, David; Chernin, Leonid; Höfte, Monica M
2009-01-22
Induced resistance is a state of enhanced defensive capacity developed by a plant reacting to specific biotic or chemical stimuli. Over the years, several forms of induced resistance have been characterized, including systemic acquired resistance, which is induced upon localized infection by an avirulent necrotizing pathogen, and induced systemic resistance (ISR), which is elicited by selected strains of nonpathogenic rhizobacteria. However, contrary to the relative wealth of information on inducible defense responses in dicotyledoneous plants, our understanding of the molecular mechanisms underlying induced resistance phenomena in cereal crops is still in its infancy. Using a combined cytomolecular and pharmacological approach, we analyzed the host defense mechanisms associated with the establishment of ISR in rice by the rhizobacterium Serratia plymuthica IC1270. In a standardized soil-based assay, root treatment with IC1270 rendered foliar tissues more resistant to the hemibiotrophic pathogen Magnaporthe oryzae, causal agent of the devastating rice blast disease. Analysis of the cytological and biochemical alterations associated with restriction of fungal growth in IC1270-induced plants revealed that IC1270 primes rice for enhanced attacker-induced accumulation of reactive oxygen species (ROS) and autofluorescent phenolic compounds in and near epidermal cells displaying dense cytoplasmic granulation. Similar, yet more abundant, phenotypes of hypersensitively dying cells in the vicinity of fungal hyphae were evident in a gene-for-gene interaction with an avirulent M. oryzae strain, suggesting that IC1270-inducible ISR and R protein conditioned effector-triggered immunity (ETI) target similar defense mechanisms. Yet, this IC1270-inducible ISR response seems to act as a double-edged sword within the rice defense network as induced plants displayed an increased vulnerability to the necrotrophic pathogens Rhizoctonia solani and Cochliobolus miyabeanus. Artificial enhancement of ROS levels in inoculated leaves faithfully mimicked the opposite effects of IC1270 bacteria on aforementioned pathogens, suggesting a central role for oxidative events in the IC1270-induced resistance mechanism. Besides identifying ROS as modulators of antagonistic defense mechanisms in rice, this work reveals the mechanistic similarities between S. plymuthica-mediated ISR and R protein-dictated ETI and underscores the importance of using appropriate innate defense mechanisms when breeding for broad-spectrum rice disease resistance.
Byun, Youngjae; Rodriguez, Katia; Han, Jung H; Kim, Young Teck
2015-11-01
The effects of the incorporation of PLA-β-cyclodextrin-inclusion complex (IC) and β-cyclodextrin (β-CD) on biopolyester PLA films were investigated. Thermal stability, surface morphology, barrier, and mechanical properties of the films were measured at varying IC (1, 3, 5, and 7%) and β-CD (1 and 5%) concentrations. The PLA-IC-composite films (IC-PLA-CFs) showed uniform morphological structure, while samples containing β-CD (β-CD-PLA-CFs) showed high agglomeration of β-CD due to poor interfacial interaction between β-CD and PLA moieties. According to the thermal property analysis, the 5% IC-PLA-CFs showed 6.6 times lower dimensional changes (6.5%) at the temperature range of 20-80°C than that of pure PLA film (43.0%). The increase of IC or β-CD content in the PLA-composite films shifted the glass transition and crystallization temperature to higher temperature regions. The crystallinity of both composite films improved by increasing IC or β-CD content. Both composite films had higher oxygen and water vapor permeability as IC or β-CD content increased in comparison to pure PLA film. All the composite films had less flexibility and lower tensile strength than the pure PLA film. In conclusion, this study shows that the IC technique is valuable to improve the thermal expansion stability of PLA-based films. Published by Elsevier B.V.
The antioxidant activity test by using DPPH method from the white tea using different solvents
NASA Astrophysics Data System (ADS)
Darmajana, Doddy A.; Hadiansyah, Firman; Desnilasari, Dewi
2017-11-01
The solvents used in this study are: aquades, ethanol and glacial acetic acid. The raw material as the source of antioxidants is white tea. Pure Quercetin is used as a comparing antioxidant. The treatment design was the solvent type for extraction, while the antioxidant activity was tested using DPPH method, with IC50 as the reference of antioxidant activity value. The results of antioxidant activity tests with three different solvent types are IC50 of 22,499 µg/mL for aquades, IC50 of 13,317 µg/mL for Ethanol and IC50 of 60,555 µg/mL for Glacial Acetic Acid. As a control of the standard antioxidant activity value of Quercetin is 4,313 µg/mL.
Critical dimension control using ultrashort laser for improving wafer critical dimension uniformity
NASA Astrophysics Data System (ADS)
Avizemer, Dan; Sharoni, Ofir; Oshemkov, Sergey; Cohen, Avi; Dayan, Asaf; Khurana, Ranjan; Kewley, Dave
2015-07-01
Requirements for control of critical dimension (CD) become more demanding as the integrated circuit (IC) feature size specifications become tighter and tighter. Critical dimension control, also known as CDC, is a well-known laser-based process in the IC industry that has proven to be robust, repeatable, and efficient in adjusting wafer CD uniformity (CDU) [Proc. SPIE
Truman, C C; Strickland, T C; Potter, T L; Franklin, D H; Bosch, D D; Bednarz, C W
2007-01-01
The low-carbon, intensively cropped Coastal Plain soils of Georgia are susceptible to runoff, soil loss, and drought. Reduced tillage systems offer the best management tool for sustained row crop production. Understanding runoff, sediment, and chemical losses from conventional and reduced tillage systems is expected to improve if the effect of a variable rainfall intensity storm was quantified. Our objective was to quantify and compare effects of a constant (Ic) intensity pattern and a more realistic, observed, variable (Iv) rainfall intensity pattern on runoff (R), sediment (E), and carbon losses (C) from a Tifton loamy sand cropped to conventional-till (CT) and strip-till (ST) cotton (Gossypium hirsutum L.). Four treatments were evaluated: CT-Ic, CT-Iv, ST-Ic, and ST-Iv, each replicated three times. Field plots (n=12), each 2 by 3 m, were established on each treatment. Each 6-m2 field plot received simulated rainfall at a constant (57 mm h(-1)) or variable rainfall intensity pattern for 70 min (12-run ave.=1402 mL; CV=3%). The Iv pattern represented the most frequent occurring intensity pattern for spring storms in the region. Compared with CT, ST decreased R by 2.5-fold, E by 3.5-fold, and C by 7-fold. Maximum runoff values for Iv events were 1.6-fold higher than those for Ic events and occurred 38 min earlier. Values for Etot and Ctot for Iv events were 19-36% and 1.5-fold higher than corresponding values for Ic events. Values for Emax and Cmax for Iv events were 3-fold and 4-fold higher than corresponding values for Ic events. Carbon enrichment ratios (CER) were
Normahani, Pasha; Kwasnicki, Richard; Bicknell, Colin; Allen, Louise; Jenkins, Mike P; Gibbs, Richard; Cheshire, Nicholas; Darzi, Ara; Riga, Celia
2017-05-11
To evaluate the effect of using wearable activity monitors (WAMs) in patients with intermittent claudication (IC) within a single-center randomized controlled trial. WAMs allow users to set daily activity targets and monitor their progress. They may offer an alternative treatment to supervised exercise programs (SEPs) for patients with IC. Thirty-seven patients with IC were recruited and randomized into intervention or control group. The intervention consisted of a feedback-enabled, wrist-worn activity monitor (WAM) in addition to access to SEP. The control group was given access to SEP only. The outcome measures were maximum walking distance (MWD), claudication distance (CD), and quality of life as measured by the VascuQol questionnaire. Participants were assessed upon recruitment, and at 3, 6, and 12 months. Patients in the WAM group showed significant improvement in MWD at 3 and 6 months (80-112 m, to 178 m; P < 0.001), which was sustained at 12 months. The WAM group also increased CD (40 vs 110 m; P < 0.001) and VascuQol score (4.7 vs 5.8; P = 0.004). The control group saw a temporary increase in VascuQol score at 6 months (4.5 vs 4.7; P = 0.028), but no other improvements in MWD or CD were observed. Significantly higher improvements in MWD were seen in the WAM group compared with that in the control group at 6 months (82 vs -5 m; P = 0.009, r = 0.47) and 12 months (69 vs 7.5 m; P = 0.011, r = 0.52). The study demonstrates the significant, sustained benefit of WAM-led technologies for patients with IC. This potentially resource-sparing intervention is likely to provide a valuable adjunct or alternative to SEP.
Asthma medication adherence: the role of God and other health locus of control factors.
Ahmedani, Brian K; Peterson, Edward L; Wells, Karen E; Rand, Cynthia S; Williams, L Keoki
2013-02-01
Medication adherence is an important determinant of disease outcomes, yet medication use on average tends to be low among patients with chronic conditions, including asthma. Although several predictors of non-adherence have been assessed, more research is needed on patients' beliefs about God and how these relate to medication use. To examine the relationship between perceptions about "God's" role in health and other locus of control factors with inhaled corticosteroid (ICS) adherence among asthma patients. Participants were from a clinical trial to improve ICS adherence and were 5-56 years old, had a diagnosis of asthma, and were receiving ICS medication. Baseline adherence was estimated from electronic prescription and pharmacy fill records. Patients were considered to be adherent if ICS use was ≥80% of prescribed. A baseline survey with the Multidimensional Health Locus of Control scale was used to assess five sources (God, doctors, other people, chance, and internal). Medication adherence was low (36%). Patients' who had a stronger belief that God determined asthma control were less likely to be adherent (odds ratio [OR] 0.82, 95% confidence interval [CI] 0.70-0.96). This relationship was stronger among African American (OR 0.68, 95% CI0.47-0.99) compared to white patients (OR 0.89, 95% CI 0.75-1.04), and among adults (OR 0.81, 95% CI 0.69-0.96) compared to children (OR 0.84, 95% CI 0.58-1.22). Patients' belief in God's control of health appears to be a factor in asthma controller use, and therefore should be considered in physician-patient discussions concerning course of treatment. ClinicalTrials.gov: NCT00459368. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
A miniature batteryless health and usage monitoring system based on hybrid energy harvesting
NASA Astrophysics Data System (ADS)
Huang, Chenling; Chakrabartty, Shantanu
2011-04-01
The cost and size of the state-of-the-art health and usage monitoring systems (HUMS) are determined by capacity of on-board energy storage which limits their large scale deployment. In this paper, we present a miniature low-cost mechanical HUMS integrated circuit (IC) based on the concept of hybrid energy harvesting where continuous monitoring is achieved by self-powering, where as the programming, localization and communication with the sensor is achieved using remote RF powering. The self-powered component of the proposed HUMS is based on our previous result which used a controllable hot electron injection on floatinggate transistor as an ultra-low power signal processor. We show that the HUMS IC can seamlessly switch between different energy harvesting modes based on the availability of ambient RF power and that the configuration, programming and communication functions can be remotely performed without physically accessing the HUMS device. All the measured results presented in this paper have been obtained from prototypes fabricated in a 0.5 micron standard CMOS process and the entire system has been successfully integrated on a 1.5cm x 1.5cm package.
Fernandes, Sheila Marques; Martins, Daniel Malisani; da Fonseca, Cassiane Dezoti; Watanabe, Mirian; Vattimo, Maria de Fátima Fernandes
2016-01-01
Iodinated contrast (IC) is clinically used in diagnostic and interventional procedures, but its use can result in contrast-induced acute kidney injury (CI-AKI). Chronic kidney disease (CKD) and chronic hyperglycemia (CH) are important predisposing factors to CI-AKI. The aim of this study was to investigate the impact of iodinated contrast on the renal function and hemodynamics in rats with chronic hyperglycemia and chronic kidney disease. A total of 30 rats were divided into six groups; Sham: control of chronic renal disease; Citrate: control of chronic hyperglycemia (CH); Nx5/6: rats with 5/6 nephrectomy; Chronic Hyperglycemia: rats receiving Streptozotocin 65 mg/kg; Nx5/6 + IC: rats Nx5/6 received 6 mL/kg of IC; CH + IC: Chronic hyperglycemia rats receiving 6 mL/kg of IC. Renal function (inulin clearance; urinary neutrophil gelatinase-associated lipocalin, NGAL) and hemodynamics (arterial blood pressure; renal blood flow; renal vascular resistance) were evaluated. Iodinated contrast significantly increased urinary NGAL and reduced inulin clearance, while the hemodynamics parameters showed changes in arterial blood pressure, renal blood flow, and renal vascular resistance in both CKD and CH groups. The results suggest that the iodinated contrast in risk factors models has important impact on renal function and hemodynamics. NGAL was confirmed to play a role of highlight in diagnosis of CI-AKI. PMID:27034930
Beauchamp, Kathryn G; Kahn, Lauren E; Berkman, Elliot T
2016-09-01
Inhibitory control (IC) is a critical neurocognitive skill for successfully navigating challenges across domains. Several studies have attempted to use training to improve neurocognitive skills such as IC, but few have found that training generalizes to performance on non-trained tasks. We used functional magnetic resonance imaging (fMRI) to investigate the effect of IC training on a related but untrained emotion regulation (ER) task with the goal of clarifying how training alters brain function and why its effects typically do not transfer across tasks. We suggest hypotheses for training-related changes in activation relevant to transfer effects: the strength model and several plausible alternatives (shifting priorities, stimulus-response automaticity, scaffolding). Sixty participants completed three weeks of IC training and underwent fMRI scanning before and after. The training produced pre- to post-training changes in neural activation during the ER task in the absence of behavioral changes. Specifically, individuals in the training group demonstrated reduced activation during ER in the left inferior frontal gyrus and supramarginal gyrus, key regions in the IC neural network. This result is less consistent with the strength model and more consistent with a motivational account. Implications for future work aiming to further pinpoint mechanisms of training transfer are discussed. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Intracellular Insulin-like Growth Factor-I Induces Bcl-2 Expression in Airway Epithelial Cells 1
Chand, Hitendra S.; Harris, Jennifer Foster; Mebratu, Yohannes; Chen, Yangde; Wright, Paul S.; Randell, Scott H.; Tesfaigzi, Yohannes
2012-01-01
Bcl-2, a prosurvival protein, regulates programmed cell death during development and repair processes, and can be oncogenic when cell proliferation is deregulated. The present study investigated what factors modulate Bcl-2 expression in airway epithelial cells and identified the pathways involved. Microarray analysis of mRNA from airway epithelial cells captured by laser microdissection showed that increased expression of IL-1β and IGF-1 coincided with induced Bcl-2 expression compared to controls. Treatment of cultured airway epithelial cells with IL-1β and IGF-1 induced Bcl-2 expression by increasing Bcl-2 mRNA stability with no discernible changes in promoter activity. Silencing the IGF-1 expression using shRNA showed that intracellular (IC)-IGF-1 was increasing Bcl-2 expression. Blocking EGFR or IGF-1R activation also suppressed IC-IGF-1, and abolished the Bcl-2 induction. Induced expression and co-localization of IC-IGF-1 and Bcl-2 were observed in airway epithelial cells of mice exposed to LPS or cigarette smoke and of patients with cystic fibrosis and chronic bronchitis but not in the respective controls. These studies demonstrate that IC-IGF-1 induces Bcl-2 expression in epithelial cells via IGF-1R and EGFR pathways, and targeting IC-IGF-1 could be beneficial to treat chronic airway diseases. PMID:22461702
Cost optimization in low volume VLSI circuits
NASA Technical Reports Server (NTRS)
Cook, K. B., Jr.; Kerns, D. V., Jr.
1982-01-01
The relationship of integrated circuit (IC) cost to electronic system cost is developed using models for integrated circuit cost which are based on design/fabrication approach. Emphasis is on understanding the relationship between cost and volume for custom circuits suitable for NASA applications. In this report, reliability is a major consideration in the models developed. Results are given for several typical IC designs using off the shelf, full custom, and semicustom IC's with single and double level metallization.