Utilizing Internet Technologies in Observatory Control Systems
NASA Astrophysics Data System (ADS)
Cording, Dean
2002-12-01
The 'Internet boom' of the past few years has spurred the development of a number of technologies to provide services such as secure communications, reliable messaging, information publishing and application distribution for commercial applications. Over the same period, a new generation of computer languages have also developed to provide object oriented design and development, improved reliability, and cross platform compatibility. Whilst the business models of the 'dot.com' era proved to be largely unviable, the technologies that they were based upon have survived and have matured to the point were they can now be utilized to build secure, robust and complete observatory control control systems. This paper will describe how Electro Optic Systems has utilized these technologies in the development of its third generation Robotic Observatory Control System (ROCS). ROCS provides an extremely flexible configuration capability within a control system structure to provide truly autonomous robotic observatory operation including observation scheduling. ROCS was built using Internet technologies such as Java, Java Messaging Service (JMS), Lightweight Directory Access Protocol (LDAP), Secure Sockets Layer (SSL), eXtendible Markup Language (XML), Hypertext Transport Protocol (HTTP) and Java WebStart. ROCS was designed to be capable of controlling all aspects of an observatory and be able to be reconfigured to handle changing equipment configurations or user requirements without the need for an expert computer programmer. ROCS consists of many small components, each designed to perform a specific task, with the configuration of the system specified using a simple meta language. The use of small components facilitates testing and makes it possible to prove that the system is correct.
The TJO-OAdM robotic observatory: OpenROCS and dome control
NASA Astrophysics Data System (ADS)
Colomé, Josep; Francisco, Xavier; Ribas, Ignasi; Casteels, Kevin; Martín, Jonatan
2010-07-01
The Telescope Joan Oró at the Montsec Astronomical Observatory (TJO - OAdM) is a small-class observatory working in completely unattended control. There are key problems to solve when a robotic control is envisaged, both on hardware and software issues. We present the OpenROCS (ROCS stands for Robotic Observatory Control System), an open source platform developed for the robotic control of the TJO - OAdM and similar astronomical observatories. It is a complex software architecture, composed of several applications for hardware control, event handling, environment monitoring, target scheduling, image reduction pipeline, etc. The code is developed in Java, C++, Python and Perl. The software infrastructure used is based on the Internet Communications Engine (Ice), an object-oriented middleware that provides object-oriented remote procedure call, grid computing, and publish/subscribe functionality. We also describe the subsystem in charge of the dome control: several hardware and software elements developed to specially protect the system at this identified single point of failure. It integrates a redundant control and a rain detector signal for alarm triggering and it responds autonomously in case communication with any of the control elements is lost (watchdog functionality). The self-developed control software suite (OpenROCS) and dome control system have proven to be highly reliable.
Kazner, C; Jamil, S; Phuntsho, S; Shon, H K; Wintgens, T; Vigneswaran, S
2014-01-01
While high quality water reuse based on dual membrane filtration (membrane filtration or ultrafiltration, followed by reverse osmosis) is expected to be progressively applied, treatment and sustainable management of the produced reverse osmosis concentrate (ROC) are still important issues. Forward osmosis (FO) is a promising technology for maximising water recovery and further dewatering ROC so that zero liquid discharge is produced. Elevated concentrations of organic and inorganic compounds may act as potential foulants of the concentrate desalting system, in that they consist of, for example, FO and a subsequent crystallizer. The present study investigated conditions under which the FO system can serve as concentration phase with the focus on its fouling propensity using model foulants and real ROC. Bulk organics from ROC consisted mainly of humic acids (HA) and building blocks since wastewater-derived biopolymers were retained by membrane filtration or ultrafiltration. Organic fouling of the FO system by ROC-derived bulk organics was low. HA was only adsorbed moderately at about 7% of the initial concentration, causing a minor flux decline of about 2-4%. However, scaling was a major impediment to this process if not properly controlled, for instance by pH adjustment or softening.
The TOTEM T1 read out card motherboard
NASA Astrophysics Data System (ADS)
Minutoli, S.; Lo Vetere, M.; Robutti, E.
2010-12-01
This article describes the Read Out Card (ROC) motherboard, which is the main component of the T1 forward telescope front-end electronic system. The ROC main objectives are to acquire tracking data and trigger information from the detector. It performs data conversion from electrical to optical format and transfers the data streams to the next level of the system and it implements Slow Control modules which are able to receive, decode and distribute the LHC machine low jitter clock and fast command. The ROC also provides a spy mezzanine connection based on programmable FPGA and USB2.0 for laboratory and portable DAQ debugging system.
OpenROCS: a software tool to control robotic observatories
NASA Astrophysics Data System (ADS)
Colomé, Josep; Sanz, Josep; Vilardell, Francesc; Ribas, Ignasi; Gil, Pere
2012-09-01
We present the Open Robotic Observatory Control System (OpenROCS), an open source software platform developed for the robotic control of telescopes. It acts as a software infrastructure that executes all the necessary processes to implement responses to the system events that appear in the routine and non-routine operations associated to data-flow and housekeeping control. The OpenROCS software design and implementation provides a high flexibility to be adapted to different observatory configurations and event-action specifications. It is based on an abstract model that is independent of the specific hardware or software and is highly configurable. Interfaces to the system components are defined in a simple manner to achieve this goal. We give a detailed description of the version 2.0 of this software, based on a modular architecture developed in PHP and XML configuration files, and using standard communication protocols to interface with applications for hardware monitoring and control, environment monitoring, scheduling of tasks, image processing and data quality control. We provide two examples of how it is used as the core element of the control system in two robotic observatories: the Joan Oró Telescope at the Montsec Astronomical Observatory (Catalonia, Spain) and the SuperWASP Qatar Telescope at the Roque de los Muchachos Observatory (Canary Islands, Spain).
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, technicians monitor equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, elements of the ARES I-X Roll Control System, or RoCS, will undergo testing. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, technicians monitor equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, a technician adjusts equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, a technician (right) adjusts equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, technicians monitor equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, a technician monitors equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, a technician adjusts equipment during testing of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, technicians get ready to begin testing elements of the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, technicians look at some of the elements to be tested in the Ares I-X Roll Control System, or RoCS. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
2008-01-24
KENNEDY SPACE CENTER, FLA. -- In the hypergolic maintenance facility at NASA's Kennedy Space Center, some of the internal elements seen here of the ARES I-X Roll Control System, or RoCS, will undergo testing. The RoCS Servicing Simulation Test is to gather data that will be used to help certify the ground support equipment design and validate the servicing requirements and processes. The RoCS is part of the Interstage structure, the lowest axial segment of the Upper Stage Simulator. In an effort to reduce costs and meet the schedule, most of the ground support equipment that will be used for the RoCS servicing is of space shuttle heritage. This high-fidelity servicing simulation will provide confidence that servicing requirements can be met with the heritage system. At the same time, the test will gather process data that will be used to modify or refine the equipment and processes to be used for the actual flight element. Photo credit: NASA/Kim Shiflett
NASA Technical Reports Server (NTRS)
Stein, William B.; Holt, K.; Holton, M.; Williams, J. H.; Butt, A.; Dervan, M.; Sharp, D.
2010-01-01
The Ares I launch vehicle is an integral part of NASA s Constellation Program, providing a foundation for a new era of space access. The Ares I is designed to lift the Orion Crew Module and will enable humans to return to the Moon as well as explore Mars.1 The Ares I is comprised of two inline stages: a Space Shuttle-derived five-segment Solid Rocket Booster (SRB) First Stage (FS) and an Upper Stage (US) powered by a Saturn V-derived J-2X engine. A dedicated Roll Control System (RoCS) located on the connecting interstage provides roll control prior to FS separation. Induced yaw and pitch moments are handled by the SRB nozzle vectoring. The FS SRB operates for approximately two minutes after which the US separates from the vehicle and the US Reaction Control System (ReCS) continues to provide reaction control for the remainder of the mission. A representation of the Ares I launch vehicle in the stacked configuration and including the Orion Crew Exploration Vehicle (CEV) is shown in Figure 1. Each Reaction Control System (RCS) design incorporates a Gaseous Helium (GHe) pressurization system combined with a monopropellant Hydrazine (N2H4) propulsion system. Both systems have two diametrically opposed thruster modules. This architecture provides one failure tolerance for function and prevention of catastrophic hazards such as inadvertent thruster firing, bulk propellant leakage, and over-pressurization. The pressurization system on the RoCS includes two ambient pressure-referenced regulators on parallel strings in order to attain the required system level single Fault Tolerant (FT) design for function while the ReCS utilizes a blow-down approach. A single burst disk and relief valve assembly is also included on the RoCS to ensure single failure tolerance for must-not-occur catastrophic hazards. The Reaction Control Systems are designed to support simultaneously firing multiple thrusters as required
A Study on the Deriving Requirements of ARGO Operation System
NASA Astrophysics Data System (ADS)
Seo, Yoon-Kyung; Rew, Dong-Young; Lim, Hyung-Chul; Park, In-Kwan; Yim, Hong-Suh; Jo, Jung Hyun; Park, Jong-Uk
2009-12-01
Korea Astronomy and Space Science Institute (KASI) has been developing one mobile and one stationary SLR system since 2008 named as ARGO-M and ARGO-F, respectively. KASI finished the step of deriving the system requirements of ARGO. The requirements include definitions and scopes of various software and hardware components which are necessary for developing the ARGO-M operation system. And the requirements define function, performance, and interface requirements. The operation system consisting of ARGO-M site, ARGO-F site, and Remote Operation Center (ROC) inside KASI is designed for remote access and the automatic tracking and control system which are the main operation concept of ARGO system. To accomplish remote operation, we are considering remote access to ARGO-F and ARGO-M from ROC. The mobile-phone service allows us to access the ARGO-F remotely and to control the system in an emergency. To implement fully automatic tracking and control function in ARGO-F, we have investigated and described the requirements about the automatic aircraft detection system and the various meteorological sensors. This paper addresses the requirements of ARGO Operation System.
NASA Technical Reports Server (NTRS)
Butt, Adam; Popp, Christopher G.; Holt, Kimberly A.; Pitts, Hank M.
2010-01-01
The Ares I launch vehicle is the selected design, chosen to return humans to the moon, Mars, and beyond. It is configured in two inline stages: the First Stage is a Space Shuttle derived five-segment Solid Rocket Booster and the Upper Stage is powered by a Saturn V derived J-2X engine. During launch, roll control for the First Stage (FS) is handled by a dedicated Roll Control System (RoCS) located on the connecting Interstage. That system will provide the Ares I with the ability to counteract induced roll torque while any induced yaw or pitch moments are handled by vectoring of the booster nozzle. This paper provides an overview of NASA s Ares I FS RoCS cold flow development test program including detailed test objectives, types of tests run to meet those objectives, an overview of the results, and applicable lessons learned. The test article was built and tested at the NASA Marshall Space Flight Center in Huntsville, AL. The FS RoCS System Development Test Article (SDTA) is a full scale, flight representative water flow test article whose primary objective was to obtain fluid system performance data to evaluate integrated system level performance characteristics and verify analytical models. Development testing and model correlation was deemed necessary as there is little historical precedent for similar large flow, pulsing systems such as the FS RoCS. The cold flow development test program consisted of flight-similar tanks, pressure regulators, and thruster valves, as well as plumbing simulating flight geometries, combined with other facility grade components and structure. Orifices downstream of the thruster valves were used to simulate the pressure drop through the thrusters. Additional primary objectives of this test program were to: evaluate system surge pressure (waterhammer) characteristics due to thruster valve operation over a range of mission duty cycles at various feed system pressures, evaluate temperature transients and heat transfer in the pressurization system, including regulator blowdown and propellant ullage performance, measure system pressure drops for comparison to analysis of tubing and components, and validate system activation and re-activation procedures for the helium pressurant system. Secondary objectives included: validating system processes for loading, unloading, and purging, validating procedures and system response for multiple failure scenarios, including relief valve operation, and evaluating system performance for contingency scenarios. The test results of the cold flow development test program are essential in validating the performance and interaction of the Roll Control System and anchoring analysis tools and results to a Critical Design Review level of fidelity.
Koopmeiners, Joseph S; Feng, Ziding
2011-01-01
The receiver operating characteristic (ROC) curve, the positive predictive value (PPV) curve and the negative predictive value (NPV) curve are three measures of performance for a continuous diagnostic biomarker. The ROC, PPV and NPV curves are often estimated empirically to avoid assumptions about the distributional form of the biomarkers. Recently, there has been a push to incorporate group sequential methods into the design of diagnostic biomarker studies. A thorough understanding of the asymptotic properties of the sequential empirical ROC, PPV and NPV curves will provide more flexibility when designing group sequential diagnostic biomarker studies. In this paper we derive asymptotic theory for the sequential empirical ROC, PPV and NPV curves under case-control sampling using sequential empirical process theory. We show that the sequential empirical ROC, PPV and NPV curves converge to the sum of independent Kiefer processes and show how these results can be used to derive asymptotic results for summaries of the sequential empirical ROC, PPV and NPV curves.
Koopmeiners, Joseph S.; Feng, Ziding
2013-01-01
The receiver operating characteristic (ROC) curve, the positive predictive value (PPV) curve and the negative predictive value (NPV) curve are three measures of performance for a continuous diagnostic biomarker. The ROC, PPV and NPV curves are often estimated empirically to avoid assumptions about the distributional form of the biomarkers. Recently, there has been a push to incorporate group sequential methods into the design of diagnostic biomarker studies. A thorough understanding of the asymptotic properties of the sequential empirical ROC, PPV and NPV curves will provide more flexibility when designing group sequential diagnostic biomarker studies. In this paper we derive asymptotic theory for the sequential empirical ROC, PPV and NPV curves under case-control sampling using sequential empirical process theory. We show that the sequential empirical ROC, PPV and NPV curves converge to the sum of independent Kiefer processes and show how these results can be used to derive asymptotic results for summaries of the sequential empirical ROC, PPV and NPV curves. PMID:24039313
NASA Astrophysics Data System (ADS)
Lai, Chao-Jen; Shaw, Chris C.; Whitman, Gary J.; Yang, Wei T.; Dempsey, Peter J.
2005-04-01
The purpose of this study is to compare the detection performance of three different mammography systems: screen/film (SF) combination, a-Si/CsI flat-panel (FP-), and charge-coupled device (CCD-) based systems. A 5-cm thick 50% adipose/50% glandular breast tissue equivalent slab phantom was used to provide an uniform background. Calcium carbonate grains of three different size groups were used to simulate microcalcifications (MCs): 112-125, 125-140, and 140-150 μm overlapping with the uniform background. Calcification images were acquired with the three mammography systems. Digital images were printed on hardcopy films. All film images were displayed on a mammographic viewer and reviewed by 5 mammographers. The visibility of the MC was rated with a 5-point confidence rating scale for each detection task, including the negative controls. Scores were averaged over all readers for various detectors and size groups. Receiver operating characteristic (ROC) analysis was performed and the areas under the ROC curves (Az"s) were computed for various imaging conditions. The results shows that (1) the FP-based system performed significantly better than the SF and CCD-based systems for individual size groups using ROC analysis (2) the FP-based system also performed significantly better than the SF and CCD-based systems for individual size groups using averaged confidence scale, and (3) the results obtained from the Az"s were largely correlated with these from confidence level scores. However, the correlation varied slightly among different imaging conditions.
Search for Partner Proteins of A. thaliana Immunophilins Involved in the Control of Plant Immunity.
Abdeeva, Inna A; Pogorelko, Gennady V; Maloshenok, Liliya G; Mokrykova, Maria V; Fursova, Oksana V; Bruskin, Sergey A
2018-04-19
The involvement of plant immunophilins in multiple essential processes such as development, various ways of adapting to biotic and abiotic stresses, and photosynthesis has already been established. Previously, research has demonstrated the involvement of three immunophilin genes ( AtCYP19-1/ROC3 , AtFKBP65/ROF2 , and AtCYP57 ) in the control of plant response to invasion by various pathogens. Current research attempts to identify host target proteins for each of the selected immunophilins. As a result, candidate interactors have been determined and confirmed using a yeast 2-hybrid (Y2H) system for protein⁻protein interaction assays. The generation of mutant isoforms of ROC3 and AtCYP57 harboring substituted amino acids in the in silico-predicted active sites became essential to achieving significant binding to its target partners. This data shows that ROF2 targets calcium-dependent lipid-binding domain-containing protein (At1g70790; AT1) and putative protein phosphatase (At2g30020; АТ2), whereas ROC3 interacts with GTP-binding protein (At1g30580; ENGD-1) and RmlC-like cupin (At5g39120). The immunophilin AtCYP57 binds to putative pyruvate decarboxylase-1 (Pdc1) and clathrin adaptor complex-related protein (At5g05010). Identified interactors confirm our previous findings that immunophilins ROC3 , ROF2 , and AtCYP57 are directly involved with stress response control. Further, these findings extend our understanding of the molecular functional pathways of these immunophilins.
A tutorial on the use of ROC analysis for computer-aided diagnostic systems.
Scheipers, Ulrich; Perrey, Christian; Siebers, Stefan; Hansen, Christian; Ermert, Helmut
2005-07-01
The application of the receiver operating characteristic (ROC) curve for computer-aided diagnostic systems is reviewed. A statistical framework is presented and different methods of evaluating the classification performance of computer-aided diagnostic systems, and, in particular, systems for ultrasonic tissue characterization, are derived. Most classifiers that are used today are dependent on a separation threshold, which can be chosen freely in many cases. The separation threshold separates the range of output values of the classification system into different target groups, thus conducting the actual classification process. In the first part of this paper, threshold specific performance measures, e.g., sensitivity and specificity, are presented. In the second part, a threshold-independent performance measure, the area under the ROC curve, is reviewed. Only the use of separation threshold-independent performance measures provides classification results that are overall representative for computer-aided diagnostic systems. The following text was motivated by the lack of a complete and definite discussion of the underlying subject in available textbooks, references and publications. Most manuscripts published so far address the theme of performance evaluation using ROC analysis in a manner too general to be practical for everyday use in the development of computer-aided diagnostic systems. Nowadays, the user of computer-aided diagnostic systems typically handles huge amounts of numerical data, not always distributed normally. Many assumptions made in more or less theoretical works on ROC analysis are no longer valid for real-life data. The paper aims at closing the gap between theoretical works and real-life data. The review provides the interested scientist with information needed to conduct ROC analysis and to integrate algorithms performing ROC analysis into classification systems while understanding the basic principles of classification.
Automatic Target Recognition Classification System Evaluation Methodology
2002-09-01
Testing Set of Two-Class XOR Data (250 Samples)......................................... 2-59 2.27 Decision Analysis Process Flow Chart...ROC curve meta - analysis , which is the estimation of the true ROC curve of a given diagnostic system through ROC analysis across many studies or...technique can be very effective in sensitivity analysis ; trying to determine which data points have the most effect on the solution, and in
NASA Ares I Launch Vehicle Roll and Reaction Control Systems Lessons Learned
NASA Technical Reports Server (NTRS)
Butt, Adam; Popp, Chris G.; Jernigan, Frankie R.; Paseur, Lila F.; Pitts, Hank M.
2011-01-01
On April 15, 2010 President Barak Obama made the official announcement that the Constellation Program, which included the Ares I launch vehicle, would be canceled. NASA s Ares I launch vehicle was being designed to launch the Orion Crew Exploration Vehicle, returning humans to the moon, Mars, and beyond. It consisted of a First Stage (FS) five segment solid rocket booster and a liquid J-2X Upper Stage (US) engine. Roll control for the FS was planned to be handled by a dedicated Roll Control System (RoCS), located on the connecting interstage. Induced yaw or pitch moments experienced during FS ascent would have been handled by vectoring of the booster nozzle. After FS booster separation, the US Reaction Control System (ReCS) would have provided the US Element with three degrees of freedom control as needed. The lessons learned documented in this paper will be focused on the technical designs and producibility of both systems along with the partnership between NASA and Boeing, who was on contract to build the Ares I US Element, which included the FS RoCS and US ReCS. In regards to partnership, focus will be placed on integration along with technical work accomplished by Boeing with special emphasis on each task order. In summary, this paper attempts to capture key lessons learned that should be helpful in the development of future launch vehicle RCS designs.
Sun, Ying-Xue; Yang, Zhe; Ye, Tao; Shi, Na; Tian, Yuan
2016-07-01
Reverse osmosis concentrate (ROC) from municipal wastewater reclamation reverse osmosis (mWRRO) contains elevated concentrations of contaminants which pose potential risks to aquatic environment. The treatment of ROC from an mWRRO using granular activated carbon (GAC) combined pretreatment of coagulation was optimized and evaluated. Among the three coagulants tested, ferric chloride (FeCl3) presented relatively higher DOC removal efficiency than polyaluminium chloride and lime at the same dosage and coagulation conditions. The removal efficiency of DOC, genotoxicity, and antiestrogenic activity concentration of the ROC could achieve 16.9, 18.9, and 39.7 %, respectively, by FeCl3 coagulation (with FeCl3 dosage of 180.22 mg/L), which can hardly reduce UV254 and genotoxicity normalized by DOC of the DOM with MW <5 kDa. However, the post-GAC adsorption column (with filtration velocity of 5.7 m/h, breakthrough point adsorption capacity of 0.22 mg DOC/g GAC) exhibited excellent removal efficiency on the dominant DOM fraction of MW <5 kDa in the ROC. The removal efficiency of DOC, UV254, and TDS in the ROC was up to 91.8, 96, and 76.5 %, respectively, by the FeCl3 coagulation and post-GAC adsorption. Also, the DOM with both genotoxicity and antiestrogenic activity were completely eliminated by the GAC adsorption. The results suggest that GAC adsorption combined pretreatment of FeCl3 coagulation as an efficient method to control organics, genotoxicity, and antiestrogenic activity in the ROC from mWRRO system.
A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric
NASA Technical Reports Server (NTRS)
Simon, Donald L.
2011-01-01
Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed
CombiROC: an interactive web tool for selecting accurate marker combinations of omics data.
Mazzara, Saveria; Rossi, Riccardo L; Grifantini, Renata; Donizetti, Simone; Abrignani, Sergio; Bombaci, Mauro
2017-03-30
Diagnostic accuracy can be improved considerably by combining multiple markers, whose performance in identifying diseased subjects is usually assessed via receiver operating characteristic (ROC) curves. The selection of multimarker signatures is a complicated process that requires integration of data signatures with sophisticated statistical methods. We developed a user-friendly tool, called CombiROC, to help researchers accurately determine optimal markers combinations from diverse omics methods. With CombiROC data from different domains, such as proteomics and transcriptomics, can be analyzed using sensitivity/specificity filters: the number of candidate marker panels rising from combinatorial analysis is easily optimized bypassing limitations imposed by the nature of different experimental approaches. Leaving to the user full control on initial selection stringency, CombiROC computes sensitivity and specificity for all markers combinations, performances of best combinations and ROC curves for automatic comparisons, all visualized in a graphic interface. CombiROC was designed without hard-coded thresholds, allowing a custom fit to each specific data: this dramatically reduces the computational burden and lowers the false negative rates given by fixed thresholds. The application was validated with published data, confirming the marker combination already originally described or even finding new ones. CombiROC is a novel tool for the scientific community freely available at http://CombiROC.eu.
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE. PMID:28273146
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.
Laser confocal measurement system for curvature radius of lenses based on grating ruler
NASA Astrophysics Data System (ADS)
Tian, Jiwei; Wang, Yun; Zhou, Nan; Zhao, Weirui; Zhao, Weiqian
2015-02-01
In the modern optical measurement field, the radius of curvature (ROC) is one of the fundamental parameters of optical lens. Its measurement accuracy directly affects the other optical parameters, such as focal length, aberration and so on, which significantly affect the overall performance of the optical system. To meet the demand of measurement instruments for radius of curvature (ROC) with high accuracy in the market, we develop a laser confocal radius measurement system with grating ruler. The system uses the peak point of the confocal intensity curve to precisely identify the cat-eye and confocal positions and then measure the distance between these two positions by using the grating ruler, thereby achieving the high-precision measurement for the ROC. The system has advantages of high focusing sensitivity and anti-environment disturbance ability. And the preliminary theoretical analysis and experiments show that the measuring repeatability can be up to 0.8 um, which can provide an effective way for the accurate measurement of ROC.
Experimental Demonstration of Observability and Operability of Robustness of Coherence
NASA Astrophysics Data System (ADS)
Zheng, Wenqiang; Ma, Zhihao; Wang, Hengyan; Fei, Shao-Ming; Peng, Xinhua
2018-06-01
Quantum coherence is an invaluable physical resource for various quantum technologies. As a bona fide measure in quantifying coherence, the robustness of coherence (ROC) is not only mathematically rigorous, but also physically meaningful. We experimentally demonstrate the witness-observable and operational feature of the ROC in a multiqubit nuclear magnetic resonance system. We realize witness measurements by detecting the populations of quantum systems in one trial. The approach may also apply to physical systems compatible with ensemble or nondemolition measurements. Moreover, we experimentally show that the ROC quantifies the advantage enabled by a quantum state in a phase discrimination task.
Optimal joint detection and estimation that maximizes ROC-type curves
Wunderlich, Adam; Goossens, Bart; Abbey, Craig K.
2017-01-01
Combined detection-estimation tasks are frequently encountered in medical imaging. Optimal methods for joint detection and estimation are of interest because they provide upper bounds on observer performance, and can potentially be utilized for imaging system optimization, evaluation of observer efficiency, and development of image formation algorithms. We present a unified Bayesian framework for decision rules that maximize receiver operating characteristic (ROC)-type summary curves, including ROC, localization ROC (LROC), estimation ROC (EROC), free-response ROC (FROC), alternative free-response ROC (AFROC), and exponentially-transformed FROC (EFROC) curves, succinctly summarizing previous results. The approach relies on an interpretation of ROC-type summary curves as plots of an expected utility versus an expected disutility (or penalty) for signal-present decisions. We propose a general utility structure that is flexible enough to encompass many ROC variants and yet sufficiently constrained to allow derivation of a linear expected utility equation that is similar to that for simple binary detection. We illustrate our theory with an example comparing decision strategies for joint detection-estimation of a known signal with unknown amplitude. In addition, building on insights from our utility framework, we propose new ROC-type summary curves and associated optimal decision rules for joint detection-estimation tasks with an unknown, potentially-multiple, number of signals in each observation. PMID:27093544
Optimal Joint Detection and Estimation That Maximizes ROC-Type Curves.
Wunderlich, Adam; Goossens, Bart; Abbey, Craig K
2016-09-01
Combined detection-estimation tasks are frequently encountered in medical imaging. Optimal methods for joint detection and estimation are of interest because they provide upper bounds on observer performance, and can potentially be utilized for imaging system optimization, evaluation of observer efficiency, and development of image formation algorithms. We present a unified Bayesian framework for decision rules that maximize receiver operating characteristic (ROC)-type summary curves, including ROC, localization ROC (LROC), estimation ROC (EROC), free-response ROC (FROC), alternative free-response ROC (AFROC), and exponentially-transformed FROC (EFROC) curves, succinctly summarizing previous results. The approach relies on an interpretation of ROC-type summary curves as plots of an expected utility versus an expected disutility (or penalty) for signal-present decisions. We propose a general utility structure that is flexible enough to encompass many ROC variants and yet sufficiently constrained to allow derivation of a linear expected utility equation that is similar to that for simple binary detection. We illustrate our theory with an example comparing decision strategies for joint detection-estimation of a known signal with unknown amplitude. In addition, building on insights from our utility framework, we propose new ROC-type summary curves and associated optimal decision rules for joint detection-estimation tasks with an unknown, potentially-multiple, number of signals in each observation.
The average receiver operating characteristic curve in multireader multicase imaging studies
Samuelson, F W
2014-01-01
Objective: In multireader, multicase (MRMC) receiver operating characteristic (ROC) studies for evaluating medical imaging systems, the area under the ROC curve (AUC) is often used as a summary metric. Owing to the limitations of AUC, plotting the average ROC curve to accompany the rigorous statistical inference on AUC is recommended. The objective of this article is to investigate methods for generating the average ROC curve from ROC curves of individual readers. Methods: We present both a non-parametric method and a parametric method for averaging ROC curves that produce a ROC curve, the area under which is equal to the average AUC of individual readers (a property we call area preserving). We use hypothetical examples, simulated data and a real-world imaging data set to illustrate these methods and their properties. Results: We show that our proposed methods are area preserving. We also show that the method of averaging the ROC parameters, either the conventional bi-normal parameters (a, b) or the proper bi-normal parameters (c, da), is generally not area preserving and may produce a ROC curve that is intuitively not an average of multiple curves. Conclusion: Our proposed methods are useful for making plots of average ROC curves in MRMC studies as a companion to the rigorous statistical inference on the AUC end point. The software implementing these methods is freely available from the authors. Advances in knowledge: Methods for generating the average ROC curve in MRMC ROC studies are formally investigated. The area-preserving criterion we defined is useful to evaluate such methods. PMID:24884728
Metabolomic profile of systemic sclerosis patients.
Murgia, Federica; Svegliati, Silvia; Poddighe, Simone; Lussu, Milena; Manzin, Aldo; Spadoni, Tatiana; Fischetti, Colomba; Gabrielli, Armando; Atzori, Luigi
2018-05-16
Systemic sclerosis (SSc) is an autoimmune disease of unknown aetiology characterized by vascular lesions, immunological alterations and diffuse fibrosis of the skin and internal organs. Since recent evidence suggests that there is a link between metabolomics and immune mediated disease, serum metabolic profile of SSc patients and healthy controls was investigated by 1 H-NMR and GC-MS techniques. The results indicated a lower level of aspartate, alanine, choline, glutamate, and glutarate in SSc patients compared with healthy controls. Moreover, comparing patients affected by limited SSc (lcSSc) and diffuse SSc (dcSSc), 6 discriminant metabolites were identified. The multivariate analysis performed using all the metabolites significantly different revealed glycolysis, gluconeogenesis, energetic pathways, glutamate metabolism, degradation of ketone bodies and pyruvate metabolism as the most important networks. Aspartate, alanine and citrate yielded a high area under receiver-operating characteristic (ROC) curves (AUC of 0.81; CI 0.726-0.93) for discriminating SSc patients from controls, whereas ROC curve generated with acetate, fructose, glutamate, glutamine, glycerol and glutarate (AUC of 0.84; CI 0.7-0.98) discriminated between lcSSc and dcSSc. These results indicated that serum NMR-based metabolomics profiling method is sensitive and specific enough to distinguish SSc from healthy controls and provided a feasible diagnostic tool for the diagnosis and classification of the disease.
NASA Technical Reports Server (NTRS)
Butt, Adam; Paseur, Lila F.; Pitts, Hank M.
2012-01-01
On April 15, 2010 President Barak Obama made the official announcement that the Constellation Program, which included the Ares I launch vehicle, would be canceled. NASA s Ares I launch vehicle was being designed to launch the Orion Crew Exploration Vehicle, returning humans to the moon, Mars, and beyond. It consisted of a First Stage (FS) five segment solid rocket booster and a liquid J-2X Upper Stage (US) engine. Roll control for the FS was planned to be handled by a dedicated Roll Control System (RoCS), located on the connecting interstage. Induced yaw or pitch moments experienced during FS ascent would have been handled by vectoring of the booster nozzle. After FS booster separation, the US Reaction Control System (ReCS) would have provided the US Element with three degrees of freedom control as needed. The best practices documented in this paper will be focused on the technical designs and producibility of both systems along with the partnership between NASA and Boeing, who was on contract to build the Ares I US Element, which included the FS RoCS and US ReCS. In regards to partnership, focus will be placed on integration along with technical work accomplished by Boeing. This will include detailed emphasis on task orders developed between NASA and Boeing that were used to direct specific work that needed to be accomplished. In summary, this paper attempts to capture key best practices that should be helpful in the development of future launch vehicle and spacecraft RCS designs.
Neuronal Effects of Sugammadex in combination with Rocuronium or Vecuronium
Aldasoro, Martin; Jorda, Adrian; Aldasoro, Constanza; Marchio, Patricia; Guerra-Ojeda, Sol; Gimeno-Raga, Marc; Mauricio, Mª Dolores; Iradi, Antonio; Obrador, Elena; Vila, Jose Mª; Valles, Soraya L.
2017-01-01
Rocuronium (ROC) and Vecuronium (VEC) are the most currently used steroidal non-depolarizing neuromuscular blocking (MNB) agents. Sugammadex (SUG) rapidly reverses steroidal NMB agents after anaesthesia. The present study was conducted in order to evaluate neuronal effects of SUG alone and in combination with both ROC and VEC. Using MTT, CASP-3 activity and Western-blot we determined the toxicity of SUG, ROC or VEC in neurons in primary culture. SUG induces apoptosis/necrosis in neurons in primary culture and increases cytochrome C (CytC), apoptosis-inducing factor (AIF), Smac/Diablo and Caspase 3 (CASP-3) protein expression. Our results also demonstrated that both ROC and VEC prevent these SUG effects. The protective role of both ROC and VEC could be explained by the fact that SUG encapsulates NMB drugs. In BBB impaired conditions it would be desirable to control SUG doses to prevent the excess of free SUG in plasma that may induce neuronal damage. A balance between SUG, ROC or VEC would be necessary to prevent the risk of cell damage. PMID:28367082
Life-Long Cyberlearning System: A Pilot Project for the "Learning Society" in the ROC.
ERIC Educational Resources Information Center
Han, Huei-Wen; Wang, Yen-Chao
1999-01-01
Provides an overview of the implementation of lifelong learning in Taiwan, Republic of China (ROC) as part of its educational reform policy and describes a pilot project, the Lifelong Cyberlearning System. Highlights include planning architecture, Web-based learning technology, professional education, industrial and corporate assistance, and…
Dynamic thresholds and a summary ROC curve: Assessing prognostic accuracy of longitudinal markers.
Saha-Chaudhuri, P; Heagerty, P J
2018-04-19
Cancer patients, chronic kidney disease patients, and subjects infected with HIV are routinely monitored over time using biomarkers that represent key health status indicators. Furthermore, biomarkers are frequently used to guide initiation of new treatments or to inform changes in intervention strategies. Since key medical decisions can be made on the basis of a longitudinal biomarker, it is important to evaluate the potential accuracy associated with longitudinal monitoring. To characterize the overall accuracy of a time-dependent marker, we introduce a summary ROC curve that displays the overall sensitivity associated with a time-dependent threshold that controls time-varying specificity. The proposed statistical methods are similar to concepts considered in disease screening, yet our methods are novel in choosing a potentially time-dependent threshold to define a positive test, and our methods allow time-specific control of the false-positive rate. The proposed summary ROC curve is a natural averaging of time-dependent incident/dynamic ROC curves and therefore provides a single summary of net error rates that can be achieved in the longitudinal setting. Copyright © 2018 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Dick, James C.; And Others
The management information system (MIS) development project for California's Regional Occupational Centers and Programs (ROC/Ps) was conducted in 3 phases over a 12-month period. Phase I involved a literature review and field study to match MIS design features and development strategy with existing conditions in ROC/Ps. A decision support system…
Face recognition in schizophrenia: do individual and average ROCs tell the same story?
Tiberghien, Guy; Martin, Clara; Baudouin, Jean-Yves; Franck, Nicolas; Guillaume, Fabrice; Huron, Caroline
2015-01-01
Many studies have shown that recollection process is impaired in patients with schizophrenia, whereas familiarity is generally spared. However, in these studies, the Receiver Operating Characteristic (ROC) presented is average ROC likely to mask individual differences. In the present study using a face-recognition task, we computed the individual ROC of patients with schizophrenia and control participants. Each group was divided into two subgroups on the basis of the type of recognition processes implemented: recognition based on familiarity only and recognition based on familiarity and recollection. The recognition performance of the schizophrenia patients was below that of the control participants only when recognition was based solely on familiarity. For the familiarity-alone patients, the score obtained on the Scale for the Assessment of Positive Symptoms (SAPS) was correlated with the variance of the old-face familiarity. For the familiarity-recollection patients, the score obtained on the Scale for the Assessment of Negative Symptoms (SANS) was correlated with the decision criterion and with the old-face recollection probability. These results show that one cannot ascribe the impaired recognition observed in patients with schizophrenia to a recollection deficit alone. These results show that individual ROC can be used to distinguish between subtypes of schizophrenia and could serve as a basis for setting up specific cognitive remediation therapy for individuals with schizophrenia.
The ROC program: accelerated restoration of competency in a jail setting.
Rice, Kevin; Jennings, Jerry L
2014-01-01
In 29 months of operation, the restoration of competency (ROC) program provided treatment services to 192 incompetent to stand trial patients in a jail setting. The ROC restored competency for 55% of the patients in an average of 57 days compared to the state hospital average of 180 days. The average cost of treatment/restoration per admission was $15,568 compared to the state hospital average of $81,000. The ROC model accelerates needed treatment for mentally ill defendants, cuts demand for costly state hospital forensic beds, and assists jails in better managing inmates with severe psychiatric disorders--yielding major cost savings and improved care. In addition to preventing readmissions and negative behavioral episodes, the ROC improved the broader forensic system by eliminating the state hospital waiting list, accelerating access to psychiatric services, promoting local access for lawyers and family, and gaining stakeholder satisfaction.
Recent developments in imaging system assessment methodology, FROC analysis and the search model.
Chakraborty, Dev P
2011-08-21
A frequent problem in imaging is assessing whether a new imaging system is an improvement over an existing standard. Observer performance methods, in particular the receiver operating characteristic (ROC) paradigm, are widely used in this context. In ROC analysis lesion location information is not used and consequently scoring ambiguities can arise in tasks, such as nodule detection, involving finding localized lesions. This paper reviews progress in the free-response ROC (FROC) paradigm in which the observer marks and rates suspicious regions and the location information is used to determine whether lesions were correctly localized. Reviewed are FROC data analysis, a search-model for simulating FROC data, predictions of the model and a method for estimating the parameters. The search model parameters are physically meaningful quantities that can guide system optimization.
Botha, J; de Ridder, J H; Potgieter, J C; Steyn, H S; Malan, L
2013-10-01
A recently proposed model for waist circumference cut points (RPWC), driven by increased blood pressure, was demonstrated in an African population. We therefore aimed to validate the RPWC by comparing the RPWC and the Joint Statement Consensus (JSC) models via Logistic Regression (LR) and Neural Networks (NN) analyses. Urban African gender groups (N=171) were stratified according to the JSC and RPWC cut point models. Ultrasound carotid intima media thickness (CIMT), blood pressure (BP) and fasting bloods (glucose, high density lipoprotein (HDL) and triglycerides) were obtained in a well-controlled setting. The RPWC male model (LR ROC AUC: 0.71, NN ROC AUC: 0.71) was practically equal to the JSC model (LR ROC AUC: 0.71, NN ROC AUC: 0.69) to predict structural vascular -disease. Similarly, the female RPWC model (LR ROC AUC: 0.84, NN ROC AUC: 0.82) and JSC model (LR ROC AUC: 0.82, NN ROC AUC: 0.81) equally predicted CIMT as surrogate marker for structural vascular disease. Odds ratios supported validity where prediction of CIMT revealed -clinical -significance, well over 1, for both the JSC and RPWC models in African males and females (OR 3.75-13.98). In conclusion, the proposed RPWC model was substantially validated utilizing linear and non-linear analyses. We therefore propose ethnic-specific WC cut points (African males, ≥90 cm; -females, ≥98 cm) to predict a surrogate marker for structural vascular disease. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Yang, Zhongming; Dou, Jiantai; Du, Jinyu; Gao, Zhishan
2018-03-01
Non-null interferometry could use to measure the radius of curvature (ROC), we have presented a virtual quadratic Newton rings phase-shifting moiré-fringes measurement method for large ROC measurement (Yang et al., 2016). In this paper, we propose a large ROC measurement method based on the evaluation of the interferogram-quality metric by the non-null interferometer. With the multi-configuration model of the non-null interferometric system in ZEMAX, the retrace errors and the phase introduced by the test surface are reconstructed. The interferogram-quality metric is obtained by the normalized phase-shifted testing Newton rings with the spherical surface model in the non-null interferometric system. The radius curvature of the test spherical surface can be obtained until the minimum of the interferogram-quality metric is found. Simulations and experimental results are verified the feasibility of our proposed method. For a spherical mirror with a ROC of 41,400 mm, the measurement accuracy is better than 0.13%.
Mori, Masayuki X; Itsuki, Kyohei; Hase, Hideharu; Sawamura, Seishiro; Kurokawa, Tatsuki; Mori, Yasuo; Inoue, Ryuji
2015-01-01
Transient receptor potential canonical (TRPC) channels are Ca(2+)-permeable, nonselective cation channels that carry receptor-operated Ca(2+) currents (ROCs) triggered by receptor-induced, phospholipase C (PLC)-catalyzed hydrolysis of phosphatidylinositol 4,5-bisphosphate [PI(4,5)P2]. Within the vasculature, TRPC channel ROCs contribute to smooth muscle cell depolarization, vasoconstriction, and vascular remodeling. However, TRPC channel ROCs exhibit a variable response to receptor-stimulation, and the regulatory mechanisms governing TRPC channel activity remain obscure. The variability of ROCs may be explained by their complex regulation by PI(4,5)P2 and its metabolites, which differentially affect TRPC channel activity. To resolve the complex regulation of ROCs, the use of voltage-sensing phosphoinositide phosphatases and model simulation have helped to reveal the time-dependent contribution of PI(4,5)P2 and the possible role of PI(4,5)P2 in the regulation of ROCs. These approaches may provide unprecedented insight into the dynamics of PI(4,5)P2 regulation of TRPC channels and the fundamental mechanisms underlying transmembrane ion flow. Within that context, we summarize the regulation of TRPC channels and their coupling to receptor-mediated signaling, as well as the application of voltage-sensing phosphoinositide phosphatases to this research. We also discuss the controversial bidirectional effects of PI(4,5)P2 using a model simulation that could explain the complicated effects of PI(4,5)P2 on different ROCs.
Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression
NASA Astrophysics Data System (ADS)
Collins, Cary A.; Lane, David; Frank, Mark S.; Hardy, Michael E.; Haynor, David R.; Smith, Donald V.; Parker, James E.; Bender, Gregory N.; Kim, Yongmin
1994-04-01
The digital archiving system at Madigan Army Medical Center (MAMC) uses a 10:1 lossy data compression algorithm for most forms of computed radiography. A systematic study on the potential effect of lossy image compression on patient care has been initiated with a series of studies focused on specific diagnostic tasks. The studies are based upon the receiver operating characteristic (ROC) method of analysis for diagnostic systems. The null hypothesis is that observer performance with approximately 10:1 compressed and decompressed images is not different from using original, uncompressed images for detecting subtle pathologic findings seen on computed radiographs of bone, chest, or abdomen, when viewed on a high-resolution monitor. Our design involves collecting cases from eight pathologic categories. Truth is determined by committee using confirmatory studies performed during routine clinical practice whenever possible. Software has been developed to aid in case collection and to allow reading of the cases for the study using stand-alone Siemens Litebox workstations. Data analysis uses two methods, ROC analysis and free-response ROC (FROC) methods. This study will be one of the largest ROC/FROC studies of its kind and could benefit clinical radiology practice using PACS technology. The study design and results from a pilot FROC study are presented.
Tanaka, Toyohiko; Nitta, Norihisa; Ohta, Shinichi; Kobayashi, Tsuyoshi; Kano, Akiko; Tsuchiya, Keiko; Murakami, Yoko; Kitahara, Sawako; Wakamiya, Makoto; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi
2009-12-01
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-μm-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages.
An universal read-out controller
NASA Astrophysics Data System (ADS)
Manz, S.; Abel, N.; Gebelein, J.; Kebschull, U.
2010-11-01
Since 2007 we design and develop a ROC (read-out controller) for FAIR's data-acquisition. While our first implementation solely focused on the nXYTER, today we are also designing and implementing readout logic for the GET4 which is supposed to be part of the ToF detector. Furthermore, we fully support both Ethernet and Optical transport as two transparent solutions. The usage of a strict modularization of the Read Out Controller enables us to provide an Universal ROC where front-end specific logic and transport logic can be combined in a very flexible way. Fault tolerance techniques are only required for some of those modules and hence are only implemented there.
Using BIRADS categories in ROC experiments
NASA Astrophysics Data System (ADS)
Kallergi, Maria; Hersh, Marla R.; Thomas, Jerry A.
2002-04-01
This paper investigated the use of the Breast Imaging Reporting And Data System (BIRADS) Lexicon in ROC mammography experiments. Analysis was based on data from parallel ROC experiments performed at two Institutions with different readers and databases to compare film to digitized mammography. Seven readers participated in the studies and read approximately 200 cases each in two formats: film and digital or softcopy. Reporting was done using BIRADS categories 1 through 5. Training was done with a separate set of cases and included detailed review of the relationship between BIRADS and a standard ROC discrete 5-point rating scale. The results from both sites showed equivalency between film and softcopy mammography. Decisions using the BIRADS categories showed no unsampled ROC regions and no degenerate data. Fits yielded smooth ROC curves that correlated to clinical practice. In a qualitative evaluation, all observers indicated preference in using the BIRADS classes instead of a discrete or continuous rating scheme. Familiarity with the rating process seems to relieve some of the bias associated with the interpretation of digitized mammograms from computer monitors (softcopy reading). Our results suggested that BIRADS categories can be used in comparative ROC studies because they represent a scale familiar to the reader that can be followed consistently and they provide a rating approach that accounts for both positive and negative cases to be evaluated and categorized.
Prohibitin plays a critical role in Enterovirus 71 neuropathogenesis
Too, Issac Horng Khit; Bonne, Isabelle; Tan, Eng Lee; Chu, Justin Jang Hann; Alonso, Sylvie
2018-01-01
A close relative of poliovirus, enterovirus 71 (EV71) is regarded as an important neurotropic virus of serious public health concern. EV71 causes Hand, Foot and Mouth Disease and has been associated with neurological complications in young children. Our limited understanding of the mechanisms involved in its neuropathogenesis has hampered the development of effective therapeutic options. Here, using a two-dimensional proteomics approach combined with mass spectrometry, we have identified a unique panel of host proteins that were differentially and dynamically modulated during EV71 infection of motor-neuron NSC-34 cells, which are found at the neuromuscular junctions where EV71 is believed to enter the central nervous system. Meta-analysis with previously published proteomics studies in neuroblastoma or muscle cell lines revealed minimal overlapping which suggests unique host-pathogen interactions in NSC-34 cells. Among the candidate proteins, we focused our attention on prohibitin (PHB), a protein that is involved in multiple cellular functions and the target of anti-cancer drug Rocaglamide (Roc-A). We demonstrated that cell surface-expressed PHB is involved in EV71 entry into neuronal cells specifically, while membrane-bound mitochondrial PHB associates with the virus replication complex and facilitates viral replication. Furthermore, Roc-A treatment of EV71-infected neuronal cells reduced significantly virus yields. However, the inhibitory effect of Roc-A on PHB in NSC-34 cells was not through blocking the CRAF/MEK/ERK pathway as previously reported. Instead, Roc-A treated NSC-34 cells had lower mitochondria-associated PHB and lower ATP levels that correlated with impaired mitochondria integrity. In vivo, EV71-infected mice treated with Roc-A survived longer than the vehicle-treated animals and had significantly lower virus loads in their spinal cord and brain, whereas virus titers in their limb muscles were comparable to controls. Together, this study uncovers PHB as the first host factor that is specifically involved in EV71 neuropathogenesis and a potential drug target to limit neurological complications. PMID:29324904
Lakhal, K; Nay, M A; Kamel, T; Lortat-Jacob, B; Ehrmann, S; Rozec, B; Boulain, T
2017-03-01
During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P <0.05). A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P <0.05) and tended to outperform Δ VE PPV (AUC ROC =0.73 [0.60-0.84], P =0.21). In the 45 patients with no arrhythmia and receiving ventilation with tidal volume <8 ml kg -1 , Δ VE E'CO2 performed better than Δ VE PPV, with AUC ROC =0.86 [0.72-0.95] vs 0.66 [0.49-0.80], P =0.02. Δ VE E'CO2 outperformed Δ VE PP, Δ VE SBP, Δ VE MBP, Δ VE FemFlow, and Δ VE HR and, during protective ventilation, arrhythmia, or both, it also outperformed Δ VE PPV. A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Ouyang, Ying; Grace, Johnny M; Zipperer, Wayne C; Hatten, Jeff; Dewey, Janet
2018-05-22
Loads of naturally occurring total organic carbons (TOC), refractory organic carbon (ROC), and labile organic carbon (LOC) in streams control the availability of nutrients and the solubility and toxicity of contaminants and affect biological activities through absorption of light and complex metals with production of carcinogenic compounds. Although computer models have become increasingly popular in understanding and management of TOC, ROC, and LOC loads in streams, the usefulness of these models hinges on the availability of daily data for model calibration and validation. Unfortunately, these daily data are usually insufficient and/or unavailable for most watersheds due to a variety of reasons, such as budget and time constraints. A simple approach was developed here to calculate daily loads of TOC, ROC, and LOC in streams based on their seasonal loads. We concluded that the predictions from our approach adequately match field measurements based on statistical comparisons between model calculations and field measurements. Our approach demonstrates that an increase in stream discharge results in increased stream TOC, ROC, and LOC concentrations and loads, although high peak discharge did not necessarily result in high peaks of TOC, ROC, and LOC concentrations and loads. The approach developed herein is a useful tool to convert seasonal loads of TOC, ROC, and LOC into daily loads in the absence of measured daily load data.
Method and system for turbomachinery surge detection
Faymon, David K.; Mays, Darrell C.; Xiong, Yufei
2004-11-23
A method and system for surge detection within a gas turbine engine, comprises: measuring the compressor discharge pressure (CDP) of the gas turbine over a period of time; determining a time derivative (CDP.sub.D ) of the measured (CDP) correcting the CDP.sub.D for altitude, (CDP.sub.DCOR); estimating a short-term average of CDP.sub.DCOR.sup.2 ; estimating a short-term average of CDP.sub.DCOR ; and determining a short-term variance of corrected CDP rate of change (CDP.sub.roc) based upon the short-term average of CDP.sub.DCOR and the short-term average of CDP.sub.DCOR.sup.2. The method and system then compares the short-term variance of corrected CDP rate of change with a pre-determined threshold (CDP.sub.proc) and signals an output when CDP.sub.roc >CDP.sub.proc. The method and system provides a signal of a surge within the gas turbine engine when CDP.sub.roc remains>CDP.sub.proc for pre-determined period of time.
Zhang, Wei; He, Yulian; Gao, Weixia; Feng, Jun; Cao, Mingfeng; Yang, Chao; Song, Cunjiang; Wang, Shufang
2015-02-01
Here, we attempted to elevate poly-gamma-glutamic acid (γ-PGA) production by modifying genes involved in glutamate metabolism in Bacillus amyloliquefaciens LL3. Products of rocR, rocG and gudB facilitate the conversion from glutamate to 2-oxoglutarate in Bacillus subtillis. The gene odhA is responsible for the synthesis of a component of the 2-oxoglutarate dehydrogenase complex that catalyzes the oxidative decarboxylation of 2-oxoglutarate to succinyl coenzyme A. In-frame deletions of these four genes were performed. In shake flask experiments the gudB/rocG double mutant presented enhanced production of γ-PGA, a 38 % increase compared with wild type. When fermented in a 5-L fermenter with pH control, the γ-PGA yield of the rocR mutant was increased to 5.83 g/L from 4.55 g/L for shake flask experiments. The gudB/rocG double mutant produced 5.68 g/L γ-PGA compared with that of 4.03 g/L for the wild type, a 40 % increase. Those results indicated the possibility of improving γ-PGA production by modifying glutamate metabolism, and identified potential genetic targets to improve γ-PGA production.
Schulze, Matthias B.; Weikert, Cornelia; Pischon, Tobias; Bergmann, Manuela M.; Al-Hasani, Hadi; Schleicher, Erwin; Fritsche, Andreas; Häring, Hans-Ulrich; Boeing, Heiner; Joost, Hans-Georg
2009-01-01
OBJECTIVE We investigated whether metabolic biomarkers and single nucleotide polymorphisms (SNPs) improve diabetes prediction beyond age, anthropometry, and lifestyle risk factors. RESEARCH DESIGN AND METHODS A case-cohort study within a prospective study was designed. We randomly selected a subcohort (n = 2,500) from 26,444 participants, of whom 1,962 were diabetes free at baseline. Of the 801 incident type 2 diabetes cases identified in the cohort during 7 years of follow-up, 579 remained for analyses after exclusions. Prediction models were compared by receiver operatoring characteristic (ROC) curve and integrated discrimination improvement. RESULTS Case-control discrimination by the lifestyle characteristics (ROC-AUC: 0.8465) improved with plasma glucose (ROC-AUC: 0.8672, P < 0.001) and A1C (ROC-AUC: 0.8859, P < 0.001). ROC-AUC further improved with HDL cholesterol, triglycerides, γ-glutamyltransferase, and alanine aminotransferase (0.9000, P = 0.002). Twenty SNPs did not improve discrimination beyond these characteristics (P = 0.69). CONCLUSIONS Metabolic markers, but not genotyping for 20 diabetogenic SNPs, improve discrimination of incident type 2 diabetes beyond lifestyle risk factors. PMID:19720844
Siemens Immulite Aspergillus-specific IgG assay for chronic pulmonary aspergillosis diagnosis.
Page, Iain D; Richardson, Malcolm D; Denning, David W
2018-05-14
Chronic pulmonary aspergillosis (CPA) complicates underlying lung disease, including treated tuberculosis. Measurement of Aspergillus-specific immunoglobulin G (IgG) is a key diagnostic step. Cutoffs have been proposed based on receiver operating characteristic (ROC) curve analyses comparing CPA cases to healthy controls, but performance in at-risk populations with underlying lung disease is unclear. We evaluated optimal cutoffs for the Siemens Immulite Aspergillus-specific IgG assay for CPA diagnosis in relation to large groups of healthy and diseased controls with treated pulmonary tuberculosis. Sera from 241 patients with CPA attending the UK National Aspergillosis Centre, 299 Ugandan blood donors (healthy controls), and 398 Ugandans with treated pulmonary tuberculosis (diseased controls) were tested. Radiological screening removed potential CPA cases from diseased controls (234 screened diseased controls). ROC curve analyses were performed and optimal cutoffs identified by Youden J statistic. CPA versus control ROC area under curve (AUC) results were: healthy controls 0.984 (95% confidence interval 0.972-0.997), diseased controls 0.972 (0.959-0.985), screened diseased controls 0.979 (0.967-0.992). Optimal cutoffs were: healthy controls 15 mg/l (94.6% sensitivity, 98% specificity), unscreened diseased controls 15 mg/l (94.6% sensitivity, 94.5% specificity), screened diseased controls 25 mg/l (92.9% sensitivity, 98.7% specificity). Results were similar in healthy and diseased controls. We advocate a cutoff of 20 mg/l as this is the midpoint of the range of optimal cutoffs. Cutoffs calculated in relation to healthy controls for other assays are likely to remain valid for use in a treated tuberculosis population.
Stourac, Petr; Adamus, Milan; Seidlova, Dagmar; Pavlik, Tomas; Janku, Petr; Krikava, Ivo; Mrozek, Zdenek; Prochazka, Martin; Klucka, Jozef; Stoudek, Roman; Bartikova, Ivana; Kosinova, Martina; Harazim, Hana; Robotkova, Hana; Hejduk, Karel; Hodicka, Zuzana; Kirchnerova, Martina; Francakova, Jana; Obare Pyszkova, Lenka; Hlozkova, Jarmila; Sevcik, Pavel
2016-05-01
Rocuronium for cesarean delivery under general anesthesia is an alternative to succinylcholine for rapid-sequence induction of anesthesia because of the availability of sugammadex for reversal of neuromuscular blockade. However, there are no large well-controlled studies in women undergoing general anesthesia for cesarean delivery. The aim of this noninferiority trial was to determine whether rocuronium and sugammadex confer benefit in time to tracheal intubation (primary outcome) and other neuromuscular blockade outcomes compared with succinylcholine, rocuronium, and neostigmine in women undergoing general anesthesia for cesarean delivery. We aimed to enroll all women undergoing general anesthesia for cesarean delivery in the 2 participating university hospitals (Brno, Olomouc, Czech Republic) in this single-blinded, randomized, controlled study. Women were randomly assigned to the ROC group (muscle relaxation induced with rocuronium 1 mg/kg and reversed with sugammadex 2-4 mg/kg) or the SUX group (succinylcholine 1 mg/kg for induction, rocuronium 0.3 mg/kg for maintenance, and neostigmine 0.03 mg/kg for reversal of the neuromuscular blockade). The interval from the end of propofol administration to tracheal intubation was the primary end point with a noninferiority margin of 20 seconds. We recorded intubating conditions (modified Viby-Mogensen score), neonatal outcome (Apgar score <7; umbilical artery pH), anesthesia complications, and subjective patient complaints 24 hours after surgery. We enrolled 240 parturients. The mean time to tracheal intubation was 2.9 seconds longer in the ROC group (95% confidence interval, -5.3 to 11.2 seconds), noninferior compared with the SUX group. Absence of laryngoscopy resistance was greater in the ROC than in the SUX groups (ROC, 87.5%; SUX, 74.2%; P = 0.019), but there were no differences in vocal cord position (P = 0.45) or intubation response (P = 0.31) between groups. No statistically significant differences in incidence of anesthesia complications or in neonatal outcome were found (10-minute Apgar score <7, P = 0.07; umbilical artery pH, P = 0.43). The incidence of postpartum myalgia was greater in the SUX group (ROC 0%; SUX 6.7%; P = 0.007). The incidence of subjective complaints was lower in the ROC group (ROC, 21.4%; SUX, 37.5%; P = 0.007). We conclude that rocuronium for rapid-sequence induction is noninferior for time to tracheal intubation and is accompanied by more frequent absence of laryngoscopy resistance and lower incidence of myalgia in comparison with succinylcholine for cesarean delivery under general anesthesia.
Improving fMRI reliability in presurgical mapping for brain tumours.
Stevens, M Tynan R; Clarke, David B; Stroink, Gerhard; Beyea, Steven D; D'Arcy, Ryan Cn
2016-03-01
Functional MRI (fMRI) is becoming increasingly integrated into clinical practice for presurgical mapping. Current efforts are focused on validating data quality, with reliability being a major factor. In this paper, we demonstrate the utility of a recently developed approach that uses receiver operating characteristic-reliability (ROC-r) to: (1) identify reliable versus unreliable data sets; (2) automatically select processing options to enhance data quality; and (3) automatically select individualised thresholds for activation maps. Presurgical fMRI was conducted in 16 patients undergoing surgical treatment for brain tumours. Within-session test-retest fMRI was conducted, and ROC-reliability of the patient group was compared to a previous healthy control cohort. Individually optimised preprocessing pipelines were determined to improve reliability. Spatial correspondence was assessed by comparing the fMRI results to intraoperative cortical stimulation mapping, in terms of the distance to the nearest active fMRI voxel. The average ROC-r reliability for the patients was 0.58±0.03, as compared to 0.72±0.02 in healthy controls. For the patient group, this increased significantly to 0.65±0.02 by adopting optimised preprocessing pipelines. Co-localisation of the fMRI maps with cortical stimulation was significantly better for more reliable versus less reliable data sets (8.3±0.9 vs 29±3 mm, respectively). We demonstrated ROC-r analysis for identifying reliable fMRI data sets, choosing optimal postprocessing pipelines, and selecting patient-specific thresholds. Data sets with higher reliability also showed closer spatial correspondence to cortical stimulation. ROC-r can thus identify poor fMRI data at time of scanning, allowing for repeat scans when necessary. ROC-r analysis provides optimised and automated fMRI processing for improved presurgical mapping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Human Factors Engineering. A Self-Paced Text, Lessons 36-40,
1981-08-01
proposed contract does not involve ’significant human interface for operation/ maintenance /control,’ the selection guide should not be used. Turn to Page 98... work space configuration, packaging, and labeling. These are all aspects of maintenance which need to be incorporated into the original design plans... work done. An ROC is a ’Required Operational Capability’ statement that is required by the Army during the system acquisition process . Return to Page
Computational Analysis of Ares I Roll Control System Jet Interaction Effects on Rolling Moment
NASA Technical Reports Server (NTRS)
Deere, Karen A.; Pao, S. Paul; Abdol-Hamid, Khaled S.
2011-01-01
The computational flow solver USM3D was used to investigate the jet interaction effects from the roll control system on the rolling moment of the Ares I full protuberance configuration at wind tunnel Reynolds numbers. Solutions were computed at freestream Mach numbers from M = 0.5 to M = 5 at the angle of attack 0deg, at the angle of attack 3.5deg for a roll angle of 120deg, and at the angle of attack 7deg for roll angles of 120deg and 210deg. Results indicate that the RoCS housing provided a beneficial jet interaction effect on vehicle rolling moment for M > or = 0.9. Most of the components downstream of the roll control system housing contributed to jet interaction penalties on vehicle rolling moment.
Qin, Yaxin; Li, Guiying; Gao, Yanpeng; Zhang, Lizhi; Ok, Yong Sik; An, Taicheng
2018-06-15
With the increased concentrations and kinds of refractory organic contaminants (ROCs) in aquatic environments, many previous reviews systematically summarized the applications of carbon-based materials in the adsorption and catalytic degradation of ROCs for their economically viable and environmentally friendly behavior. Interestingly, recent studies indicated that carbon-based materials in natural environment can also mediate the transformation of ROCs directly or indirectly due to their abundant persistent free radicals (PFRs). Understanding the formation mechanisms of PFRs in carbo-based materials and their interactions with ROCs is essential to develop their further applications in environment remediation. However, there is no comprehensive review so far about the direct and indirect removal of ROCs mediated by PFRs in amorphous, porous and crystalline carbon-based materials. The review aims to evaluate the formation mechanisms of PFRs in carbon-based materials synthesized through pyrolysis and hydrothermal carbonization processes. The influence of synthesis conditions (temperature and time) and carbon sources on the types as well as the concentrations of PFRs in carbon-based materials are also discussed. In particular, the effects of metals on the concentrations and types of PFRs in carbon-based materials are highlighted because they are considered as the catalysts for the formation of PFRs. The formation mechanisms of reactive species and the further transformation mechanisms of ROCs are briefly summarized, and the surface properties of carbon-based materials including surface area, types and number of functional groups, etc. are found to be the key parameters controlling their activities. However, due to diversity and complexity of carbon-based materials, the exact relationships between the activities of carbon-based materials and PFRs are still uncertain. Finally, the existing problems and current challenges for the ROCs transformation with carbon-based materials are also pointed out. Copyright © 2018 Elsevier Ltd. All rights reserved.
Revisiting the Roco G-protein cycle.
Terheyden, Susanne; Ho, Franz Y; Gilsbach, Bernd K; Wittinghofer, Alfred; Kortholt, Arjan
2015-01-01
Mutations in leucine-rich-repeat kinase 2 (LRRK2) are the most frequent cause of late-onset Parkinson's disease (PD). LRRK2 belongs to the Roco family of proteins which share a conserved Ras-like G-domain (Roc) and a C-terminal of Roc (COR) domain tandem. The nucleotide state of small G-proteins is strictly controlled by guanine-nucleotide-exchange factors (GEFs) and GTPase-activating proteins (GAPs). Because of contradictory structural and biochemical data, the regulatory mechanism of the LRRK2 Roc G-domain and the RocCOR tandem is still under debate. In the present study, we solved the first nucleotide-bound Roc structure and used LRRK2 and bacterial Roco proteins to characterize the RocCOR function in more detail. Nucleotide binding induces a drastic structural change in the Roc/COR domain interface, a region strongly implicated in patients with an LRRK2 mutation. Our data confirm previous assumptions that the C-terminal subdomain of COR functions as a dimerization device. We show that the dimer formation is independent of nucleotide. The affinity for GDP/GTP is in the micromolar range, the result of which is high dissociation rates in the s-1 range. Thus Roco proteins are unlikely to need GEFs to achieve activation. Monomeric LRRK2 and Roco G-domains have a similar low GTPase activity to small G-proteins. We show that GTPase activity in bacterial Roco is stimulated by the nucleotide-dependent dimerization of the G-domain within the complex. We thus propose that the Roco proteins do not require GAPs to stimulate GTP hydrolysis but stimulate each other by one monomer completing the catalytic machinery of the other.
Rostami, Kamran; Marsh, Michael N; Johnson, Matt W; Mohaghegh, Hamid; Heal, Calvin; Holmes, Geoffrey; Ensari, Arzu; Aldulaimi, David; Bancel, Brigitte; Bassotti, Gabrio; Bateman, Adrian; Becheanu, Gabriel; Bozzola, Anna; Carroccio, Antonio; Catassi, Carlo; Ciacci, Carolina; Ciobanu, Alexandra; Danciu, Mihai; Derakhshan, Mohammad H; Elli, Luca; Ferrero, Stefano; Fiorentino, Michelangelo; Fiorino, Marilena; Ganji, Azita; Ghaffarzadehgan, Kamran; Going, James J; Ishaq, Sauid; Mandolesi, Alessandra; Mathews, Sherly; Maxim, Roxana; Mulder, Chris J; Neefjes-Borst, Andra; Robert, Marie; Russo, Ilaria; Rostami-Nejad, Mohammad; Sidoni, Angelo; Sotoudeh, Masoud; Villanacci, Vincenzo; Volta, Umberto; Zali, Mohammad R; Srivastava, Amitabh
2017-01-01
Objectives Counting intraepithelial lymphocytes (IEL) is central to the histological diagnosis of coeliac disease (CD), but no definitive ‘normal’ IEL range has ever been published. In this multicentre study, receiver operating characteristic (ROC) curve analysis was used to determine the optimal cut-off between normal and CD (Marsh III lesion) duodenal mucosa, based on IEL counts on >400 mucosal biopsy specimens. Design The study was designed at the International Meeting on Digestive Pathology, Bucharest 2015. Investigators from 19 centres, eight countries of three continents, recruited 198 patients with Marsh III histology and 203 controls and used one agreed protocol to count IEL/100 enterocytes in well-oriented duodenal biopsies. Demographic and serological data were also collected. Results The mean ages of CD and control groups were 45.5 (neonate to 82) and 38.3 (2–88) years. Mean IEL count was 54±18/100 enterocytes in CD and 13±8 in normal controls (p=0.0001). ROC analysis indicated an optimal cut-off point of 25 IEL/100 enterocytes, with 99% sensitivity, 92% specificity and 99.5% area under the curve. Other cut-offs between 20 and 40 IEL were less discriminatory. Additionally, there was a sufficiently high number of biopsies to explore IEL counts across the subclassification of the Marsh III lesion. Conclusion Our ROC curve analyses demonstrate that for Marsh III lesions, a cut-off of 25 IEL/100 enterocytes optimises discrimination between normal control and CD biopsies. No differences in IEL counts were found between Marsh III a, b and c lesions. There was an indication of a continuously graded dose–response by IEL to environmental (gluten) antigenic influence. PMID:28893865
Carbon Management In the Post-Cap-and-Trade Carbon Economy-Part II
NASA Astrophysics Data System (ADS)
DeGroff, F. A.
2014-12-01
This is the second installment in our search for a comprehensive economic model to mitigate climate change due to anthropogenic activity. Last year we presented how the unique features of our economic model measure changes in carbon flux due to anthropogenic activity, referred to as carbon quality or CQ, and how the model is used to value such changes in the climate system. This year, our paper focuses on how carbon quality can be implemented to capture the effect of economic activity and international trade on the climate system, thus allowing us to calculate a Return on Climate System (RoCS) for all economic assets and activity. The result is that the RoCS for each public and private economic activity and entity can be calculated by summing up the RoCS for each individual economic asset and activity in which an entity is engaged. Such a macro-level scale is used to rank public and private entities including corporations, governments, and even entire nations, as well as human adaptation and carbon storage activities, providing status and trending insights to evaluate policies on both a micro- and macro-economic level. With international trade, RoCS measures the embodied effects on climate change that will be needed to assess border fees to insure carbon parity on all imports and exports. At the core of our vision is a comprehensive, 'open-source' construct of which our carbon quality metric is the first element. One goal is to recognize each country's endemic resources and infrastructure that affect their ability to manage carbon, while preventing spatial and temporal shifting of carbon emissions that reduce or reverse efforts to mitigate climate change. The standards for calculating the RoCS can be promulgated as part of the Generally Accepted Accounted Principles (GAAP) and the International Financial Reporting Standards (IFRS) to ensure standard and consistent reporting. The value of such insights on the climate system at all levels will be crucial to managing anthropogenic activity in order to minimize the effect on the climate system. Without the insights provided by a comprehensive, standardized and verifiable RoCS, managing anthropogenic activity will be elusive and difficult to achieve, at best. Such a model may also be useful to manage the effect of anthropogenic activity on the nitrogen and phosphorous cycles.
Glutamate Dehydrogenase Affects Resistance to Cell Wall Antibiotics in Bacillus subtilis
Lee, Yong Heon; Kingston, Anthony W.
2012-01-01
The glutamate dehydrogenase RocG of Bacillus subtilis is a bifunctional protein with both enzymatic and regulatory functions. Here we show that the rocG null mutant is sensitive to β-lactams, including cefuroxime (CEF), and to fosfomycin but that resistant mutants arise due to gain-of-function mutations in gudB, which encodes an otherwise inactive glutamate dehydrogenase. In the presence of CEF, ΔrocG ΔgudB mutant cells exhibit growth arrest when they reach mid-exponential phase. Using microarray-based transcriptional profiling, we found that the σW regulon was downregulated in the ΔrocG ΔgudB null mutant. A survey of σW-controlled genes for effects on CEF resistance identified both the NfeD protein YuaF and the flotillin homologue YuaG (FloT). Notably, overexpression of yuaFG in the rocG null mutant prevents the growth arrest induced by CEF. The YuaG flotillin has been shown previously to localize to defined lipid microdomains, and we show here that the yuaFGI operon contributes to a σW-dependent decrease in membrane fluidity. We conclude that glutamate dehydrogenase activity affects the expression of the σW regulon, by pathways that are yet unclear, and thereby influences resistance to CEF and other antibiotics. PMID:22178969
Glutamate dehydrogenase affects resistance to cell wall antibiotics in Bacillus subtilis.
Lee, Yong Heon; Kingston, Anthony W; Helmann, John D
2012-03-01
The glutamate dehydrogenase RocG of Bacillus subtilis is a bifunctional protein with both enzymatic and regulatory functions. Here we show that the rocG null mutant is sensitive to β-lactams, including cefuroxime (CEF), and to fosfomycin but that resistant mutants arise due to gain-of-function mutations in gudB, which encodes an otherwise inactive glutamate dehydrogenase. In the presence of CEF, ΔrocG ΔgudB mutant cells exhibit growth arrest when they reach mid-exponential phase. Using microarray-based transcriptional profiling, we found that the σ(W) regulon was downregulated in the ΔrocG ΔgudB null mutant. A survey of σ(W)-controlled genes for effects on CEF resistance identified both the NfeD protein YuaF and the flotillin homologue YuaG (FloT). Notably, overexpression of yuaFG in the rocG null mutant prevents the growth arrest induced by CEF. The YuaG flotillin has been shown previously to localize to defined lipid microdomains, and we show here that the yuaFGI operon contributes to a σ(W)-dependent decrease in membrane fluidity. We conclude that glutamate dehydrogenase activity affects the expression of the σ(W) regulon, by pathways that are yet unclear, and thereby influences resistance to CEF and other antibiotics.
The Implications of the Rise of China’s Military for Mongolian Security
2010-06-01
Regional Forum ASAT – Anti-satellite ASUW – Anti- surface warfare ASW – Antisubmarine Warfare AWACS – Airborne Warning and Control System CCP – Chinese...Military Region NAM – Non-Aligned Movements NATO – North Atlantic Treaty Organization NCO – Non-commissioned Officer NWFZ – Nuclear-Weapon- Free Zone...currency ROC – Republic of China RRU – Rapid Reaction Units SAM – Surface to Air Missile SCO – Shanghai Cooperation Organization SIPRI – Stockholm
Fang, Chenglong; Luo, Tingting; Lin, Ling
2017-12-01
We investigated whether serum CXC ligand 13 protein (CXCL13) levels correlate with the circulating plasmablasts and memory B-cells alteration in systemic lupus erythematosus (SLE) patients. The diagnostic use of CXCL13 concentrations in active lupus was also analyzed.A total of 36 SLE patients and 18 healthy controls were included. Serum CXCL13 levels were examined by enzyme-linked immunosorbent assay. The frequency and absolute count of circulating plasmablasts and memory B cells were analyzed by flow cytometry. Receiver operating characteristic curves (ROC curves) were generated to analyze the utility of serum CXCL13 level and plasmablasts frequency as tools for the recognition of active SLE.Elevation of serum CXCL13 levels, higher plasmablasts frequency, and reduction of memory B-cells count were observed in SLE patients, compared with healthy controls. Interestingly, correlational analyses showed not only significantly positive association between CXCL13 levels and SLE Disease Activity Index (SLEDAI) or plasmablasts frequency, but an inverse correlation between CXCL13 concentration and memory B-cell count. ROC curves showed that serum CXCL13 level and plasmablasts frequency were practical in identifying active disease from overall SLE patients, with considerable accuracy.Serum CXCL13 levels correlate with the alteration of plasmablasts and memory B cells in SLE. CXCL13 may be used as a practical tool in judgment of active SLE.
pROC: an open-source package for R and S+ to analyze and compare ROC curves.
Robin, Xavier; Turck, Natacha; Hainard, Alexandre; Tiberti, Natalia; Lisacek, Frédérique; Sanchez, Jean-Charles; Müller, Markus
2011-03-17
Receiver operating characteristic (ROC) curves are useful tools to evaluate classifiers in biomedical and bioinformatics applications. However, conclusions are often reached through inconsistent use or insufficient statistical analysis. To support researchers in their ROC curves analysis we developed pROC, a package for R and S+ that contains a set of tools displaying, analyzing, smoothing and comparing ROC curves in a user-friendly, object-oriented and flexible interface. With data previously imported into the R or S+ environment, the pROC package builds ROC curves and includes functions for computing confidence intervals, statistical tests for comparing total or partial area under the curve or the operating points of different classifiers, and methods for smoothing ROC curves. Intermediary and final results are visualised in user-friendly interfaces. A case study based on published clinical and biomarker data shows how to perform a typical ROC analysis with pROC. pROC is a package for R and S+ specifically dedicated to ROC analysis. It proposes multiple statistical tests to compare ROC curves, and in particular partial areas under the curve, allowing proper ROC interpretation. pROC is available in two versions: in the R programming language or with a graphical user interface in the S+ statistical software. It is accessible at http://expasy.org/tools/pROC/ under the GNU General Public License. It is also distributed through the CRAN and CSAN public repositories, facilitating its installation.
The ROC Curves of Fused Independent Classification Systems
2008-09-01
spectral settings arises in many fields of study; in medicine, the detection of a cancer; in marketing , the detection of the best customer base; in the...p ≤ 0.4 p/3 + 2/3, 0.4 ≤ p ≤ 1.0 fB(p) = tanh( 4p ) fC(p) = p1/3 The following plots will show how these ROC curves combine, and how the optimal
A concordance index for matched case-control studies with applications in cancer risk.
Brentnall, Adam R; Cuzick, Jack; Field, John; Duffy, Stephen W
2015-02-10
In unmatched case-control studies, the area under the receiver operating characteristic (ROC) curve (AUC) may be used to measure how well a variable discriminates between cases and controls. The AUC is sometimes used in matched case-control studies by ignoring matching, but it lacks interpretation because it is not based on an estimate of the ROC for the population of interest. We introduce an alternative measure of discrimination that is the concordance of risk factors conditional on the matching factors. Parametric and non-parametric estimators are given for different matching scenarios, and applied to real data from breast and lung cancer case-control studies. Diagnostic plots to verify the constancy of discrimination over matching factors are demonstrated. The proposed simple measure is easy to use, interpret, more efficient than unmatched AUC statistics and may be applied to compare the conditional discrimination performance of risk factors. Copyright © 2014 John Wiley & Sons, Ltd.
Wavelet and receiver operating characteristic analysis of heart rate variability
NASA Astrophysics Data System (ADS)
McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.
2002-02-01
Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.
Noda, Kyoko; Ohuchi, Yuko; Hashimoto, Akira; Fujiki, Masayuki; Itoh, Sumitaka; Iwatsuki, Satoshi; Noda, Toshiaki; Suzuki, Takayoshi; Kashiwabara, Kazuo; Takagi, Hideo D
2006-02-06
Controlled-potential electrochemical oxidation of cis-[Ru(ROCS2)2(PPh3)2] (R = Et, iPr) yielded corresponding Ru(III) complexes, and the crystal structures of cis-[Ru(ROCS2)2(PPh3)2] and trans-[Ru(ROCS2)2(PPh3)2](PF6) were determined. Both pairs of complexes exhibited almost identical coordination structures. The Ru-P distances in trans-[Ru(III)(ROCS2)2(PPh3)2](PF6) [2.436(3)-2.443(3) A] were significantly longer than those in cis-[Ru(II)(ROCS2)2(PPh3)2] [2.306(1)-2.315(2) A]: the smaller ionic radius of Ru(III) than that of Ru(II) stabilizes the trans conformation for the Ru(III) complex due to the steric requirement of bulky phosphine ligands while mutual trans influence by the phosphine ligands induces significant elongation of the Ru(III)-P bonds. Cyclic voltammograms of the cis-[Ru(ROCS2)2(PPh3)2] and trans-[Ru(ROCS2)2(PPh3)2]+ complexes in dichloromethane solution exhibited typical dual redox signals corresponding to the cis-[Ru(ROCS2)2(PPh3)2](+/0) (ca. +0.15 and +0.10 V vs ferrocenium/ferrocene couple for R = Et and iPr, respectively) and to trans-[Ru(ROCS2)2(PPh3)2](+/0) (-0.05 and -0.15 V vs ferrocenium/ferrocene for R = Et and iPr, respectively) couples. Analyses on the basis of the Nicholson and Shain's method revealed that the thermal disappearance rate of transient trans-[Ru(ROCS2)2(PPh3)2] was dependent on the concentration of PPh3 in the bulk: the rate constant for the intramolecular isomerization reaction of trans-[Ru(iPrOCS2)2(PPh3)2] was determined as 0.338 +/- 0.004 s(-1) at 298.3 K (deltaH* = 41.8 +/- 1.5 kJ mol(-1) and deltaS* = -114 +/- 7 J mol(-1) K(-1)), while the dissociation rate constant of coordinated PPh3 from the trans-[Ru(iPrOCS2)2(PPh3)2] species was estimated as 0.113 +/- 0.008 s(-1) at 298.3 K (deltaH* = 97.6 +/- 0.8 kJ mol(-1) and deltaS* = 64 +/- 3 J mol(-1) K(-1)), by monitoring the EC reaction (electrode reaction followed by chemical processes) at different concentrations of PPh3 in the bulk. It was found that the trans to cis isomerization reaction takes place via the partial dissociation of iPrOCS2(-) from Ru(II), contrary to the previous claim that it takes place by the twist mechanism.
A risk scoring system for prediction of haemorrhagic stroke.
Zodpey, S P; Tiwari, R R
2005-01-01
The present pair-matched case control study was carried out at Government Medical College Hospital, Nagpur, India, a tertiary care hospital with the objective to devise and validate a risk scoring system for prediction of hemorrhagic stroke. The study consisted of 166 hospitalized CT scan proved cases of hemorrhagic stroke (ICD 9, 431-432), and a age and sex matched control per case. The controls were selected from patients who attended the study hospital for conditions other than stroke. On conditional multiple logistic regression five risk factors- hypertension (OR = 1.9. 95% Cl = 1.5-2.5). raised scrum total cholesterol (OR = 2.3, 95% Cl = 1.1-4.9). use of anticoagulants and antiplatelet agents (OR = 3.4, 95% Cl =1.1-10.4). past history of transient ischaemic attack (OR = 8.4, 95% Cl = 2.1- 33.6) and alcohol intake (OR = 2.1, 95% Cl = 1.3-3.6) were significant. These factors were ascribed statistical weights (based on regression coefficients) of 6, 8, 12, 21 and 8 respectively. The nonsignificant factors (diabetes mellitus, physical inactivity, obesity, smoking, type A personality, history of claudication, family history of stroke, history of cardiac diseases and oral contraceptive use in females) were not included in the development of scoring system. ROC curve suggested a total score of 21 to be the best cut-off for predicting haemorrhag stroke. At this cut-off the sensitivity, specificity, positive predictivity and Cohen's kappa were 0.74, 0.74, 0.74 and 0.48 respectively. The overall predictive accuracy of this additive risk scoring system (area under ROC curve by Wilcoxon statistic) was 0.79 (95% Cl = 0.73-0.84). Thus to conclude, if substantiated by further validation, this scorincy system can be used to predict haemorrhagic stroke, thereby helping to devise effective risk factor intervention strategy.
Regional Cerebral Blood Flow In Dementia: Receiver-Operating-Characteristic Analysis
NASA Astrophysics Data System (ADS)
Zemcov, Alexander; Barclay, Laurie; Sansone, Joseph; Blass, John P.; Metz, Charles E.
1985-06-01
The coupling of mentation to regional cerebral blood flow (rCBF) has prompted the application of the Xe-133 inhalation method of measuring rCBF in the differential diagnosis of the two most common dementing diseases, Alzheimer's disease and multi-infarct dementia (MID). In this study receiver-operating-characteristic (ROC) curve analysis was used to assess the effectiveness of a 32 detector Xe-133 inhalation system in discriminating between patients with Alzheimer's disease and normal controls, MID patients and normal controls and between patients with Alzheimer's disease and MID. The populations were clinically evaluated as 1) normal (age 63.1 + 13.1, n=23), 2) Alzheimer's disease (age 72.7 + 7.0, n=82), 3) MID (age 76.4 + 7.6, n=27): The mean flow values for all detectors were lowest for the Alzheimer's disease group, larger for the MID group and largest for the normal controls. The dynamic relationship between the correct identifications (true posi-tives) versus incorrect identifications (false positives) per detector for any 2 pairs of clinical groups varies as the cutoff value of flow is changed over the range of experimental blood flow values. Therefore a quantitative characterization of the "decision" or ROC curve (TP vs FP) for each detector and for each pair of clinical groups provides a measure of the overall diagnostic efficacy of the detector. Detectors directed approximately toward the speech, auditory and association cortices were most effective in disciminatinq between each of the dementia groups and the controls. Frontal detectors were diagnostically inefficient. The Xe-133 inhalation system provided virtually no diagnostic power in discriminating between the two forms of dementia, however. Therefore this imaging technology is most useful when assessing the general diagnostic state of dementia (Alz-heimer's disease and MID) from normal cognitive function.
Rostami, Kamran; Marsh, Michael N; Johnson, Matt W; Mohaghegh, Hamid; Heal, Calvin; Holmes, Geoffrey; Ensari, Arzu; Aldulaimi, David; Bancel, Brigitte; Bassotti, Gabrio; Bateman, Adrian; Becheanu, Gabriel; Bozzola, Anna; Carroccio, Antonio; Catassi, Carlo; Ciacci, Carolina; Ciobanu, Alexandra; Danciu, Mihai; Derakhshan, Mohammad H; Elli, Luca; Ferrero, Stefano; Fiorentino, Michelangelo; Fiorino, Marilena; Ganji, Azita; Ghaffarzadehgan, Kamran; Going, James J; Ishaq, Sauid; Mandolesi, Alessandra; Mathews, Sherly; Maxim, Roxana; Mulder, Chris J; Neefjes-Borst, Andra; Robert, Marie; Russo, Ilaria; Rostami-Nejad, Mohammad; Sidoni, Angelo; Sotoudeh, Masoud; Villanacci, Vincenzo; Volta, Umberto; Zali, Mohammad R; Srivastava, Amitabh
2017-12-01
Counting intraepithelial lymphocytes (IEL) is central to the histological diagnosis of coeliac disease (CD), but no definitive 'normal' IEL range has ever been published. In this multicentre study, receiver operating characteristic (ROC) curve analysis was used to determine the optimal cut-off between normal and CD (Marsh III lesion) duodenal mucosa, based on IEL counts on >400 mucosal biopsy specimens. The study was designed at the International Meeting on Digestive Pathology, Bucharest 2015. Investigators from 19 centres, eight countries of three continents, recruited 198 patients with Marsh III histology and 203 controls and used one agreed protocol to count IEL/100 enterocytes in well-oriented duodenal biopsies. Demographic and serological data were also collected. The mean ages of CD and control groups were 45.5 (neonate to 82) and 38.3 (2-88) years. Mean IEL count was 54±18/100 enterocytes in CD and 13±8 in normal controls (p=0.0001). ROC analysis indicated an optimal cut-off point of 25 IEL/100 enterocytes, with 99% sensitivity, 92% specificity and 99.5% area under the curve. Other cut-offs between 20 and 40 IEL were less discriminatory. Additionally, there was a sufficiently high number of biopsies to explore IEL counts across the subclassification of the Marsh III lesion. Our ROC curve analyses demonstrate that for Marsh III lesions, a cut-off of 25 IEL/100 enterocytes optimises discrimination between normal control and CD biopsies. No differences in IEL counts were found between Marsh III a, b and c lesions. There was an indication of a continuously graded dose-response by IEL to environmental (gluten) antigenic influence. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Discriminability of Personality Profiles in Isolated and Co-Morbid Marijuana and Nicotine Users
Ketcherside, Ariel; Jeon-Slaughter, Haekyung; Baine, Jessica L.; Filbey, Francesca M
2016-01-01
Specific personality traits have been linked with substance use disorders (SUDs), genetic mechanisms, and brain systems. Thus, determining the specificity of personality traits to types of SUD can advance the field towards defining SUD endophenotypes as well as understanding the brain systems involved for the development of novel treatments. Disentangling these factors is particularly important in highly co-morbid SUDs, such as marijuana and nicotine use, so treatment can occur effectively for both. This study evaluated personality traits that distinguish isolated and co-morbid use of marijuana and nicotine. To that end, we collected the NEO Five Factor Inventory in participants who used marijuana-only (n=59), nicotine-only (n=27), both marijuana and nicotine (n=28), and in non-using controls (n=28). We used factor analyses to identify personality profiles, which are linear combinations of the five NEO Factors. We then conducted Receiver Operating Characteristics (ROC) curve analysis to test accuracy of the personality factors in discriminating isolated and co-morbid marijuana and nicotine users from each other. ROC curve analysis distinguished the four groups based on their NEO personality patterns. Results showed that NEO Factor 2 (openness, extraversion, agreeableness) discriminated marijuana and marijuana + nicotine users from controls and nicotine-only users with high predictability. Additional ANOVA results showed that the openness dimension discriminated marijuana users from nicotine users. These findings suggest that personality dimensions distinguish marijuana users from nicotine users and should be considered in prevention strategies. PMID:27086256
The influence of averaging and noisy decision strategies on the recognition memory ROC.
Malmberg, Kenneth J; Xu, Jing
2006-02-01
Many single- and dual-process models of recognition memory predict that the ratings and remember-know receiver operating characteristics (ROCs) are the same, but Rotello, Macmillan, and Reeder (2004) reported that the slopes of the remember-know and ratings z-transformed ROCs (zROCs) are different The authors show that averaging introduces nonlinearities to the form of the zROC and that ratings and remember-know zROCs are indistinguishable when constructed in a conventional manner. The authors show, further, that some nonoptimal decision strategies have a distinctive, nonlinear effect on the form of the single-process continuous-state zROC. The conclusion is that many factors having nothing to do with the nature of recognition memory can affect the shape of zROCs, and that therefore, the shape of the zROC does not, alone, characterize different memory models.
NASA Astrophysics Data System (ADS)
Berbaum, Kevin S.; Dorfman, Donald D.
2001-06-01
Receiver operating characteristic (ROC) data with false positive fractions of zero are often difficult to fit with standard ROC methodology, and are sometimes discarded. Some extreme examples of such data were analyzed. A new ROC model is proposed that assumes that for a proportion of abnormalities, no signal information is captured and that those abnormalities have the same distribution as noise along the latent decision axis. Rating reports of fracture for single view ankle radiographs were also analyzed with the binormal ROC model and two proper ROC models. The conventional models gave ROC area close to one, implying a true positive fraction close to one. The data contained no such fractions. When all false positive fractions were zero, conventional ROC areas gave little or no hint of unmistakable differences in true positive fractions. In contrast, the new model can fit ROC data in which some or all of the ROC points have false positive fractions of zero and true positive fractions less than one without concluding perfect performance. These data challenge the validity and robustness of conventional ROC models, but the contaminated binormal model accounts for these data. This research has been published for a different audience.
LIDAR Metrology for Prescription Characterization and Alignment of Large Mirrors
NASA Technical Reports Server (NTRS)
Eegholm, B.; Eichhorn, W.; von Handorf, R.; Hayden, J.; Ohl, R.; Wenzel, G.
2011-01-01
We describe the use of LIDAR, or "laser radar," (LR) as a fast, accurate, and non-contact tool for the measurement of the radius of curvature (RoC) of large mirrors. We report the results of a demonstration of this concept using a commercial laser radar system. We measured the RoC of a 1.4m x 1m spherical mirror with a nominal RoC of 4.6 m with a manufacturing tolerance of 4600mm +/- 6mm. The prescription of the mirror is related to its role as ground support equipment used in the test of part of the James Webb Space Telescope (JWST). The RoC of such a large mirror is not easily measured without contacting the surface. From a position near the center of curvature of the mirror, the LIDAR scanned the mirror surface, sampling it with 1 point per 3.5 sq cm. The measurement consisted of 3983 points and lasted only a few minutes. The laser radar uses the LIDAR signal to provide range, and encoder information from angular azimuth and elevation rotation stages provide the spherical coordinates of a given point. A best-fit to a sphere of the measured points was performed. The resulting RoC was within 20 ppm of the nominal RoC, also showing good agreement with the results of a laser tracker-based, contact metrology. This paper also discusses parameters such as test alignment, scan density, and optical surface type, as well as future possible application for full prescription characterization of aspherical mirrors, including radius, conic, off-axis distance, and aperture.
Transformation-invariant and nonparametric monotone smooth estimation of ROC curves.
Du, Pang; Tang, Liansheng
2009-01-30
When a new diagnostic test is developed, it is of interest to evaluate its accuracy in distinguishing diseased subjects from non-diseased subjects. The accuracy of the test is often evaluated by receiver operating characteristic (ROC) curves. Smooth ROC estimates are often preferable for continuous test results when the underlying ROC curves are in fact continuous. Nonparametric and parametric methods have been proposed by various authors to obtain smooth ROC curve estimates. However, there are certain drawbacks with the existing methods. Parametric methods need specific model assumptions. Nonparametric methods do not always satisfy the inherent properties of the ROC curves, such as monotonicity and transformation invariance. In this paper we propose a monotone spline approach to obtain smooth monotone ROC curves. Our method ensures important inherent properties of the underlying ROC curves, which include monotonicity, transformation invariance, and boundary constraints. We compare the finite sample performance of the newly proposed ROC method with other ROC smoothing methods in large-scale simulation studies. We illustrate our method through a real life example. Copyright (c) 2008 John Wiley & Sons, Ltd.
Okumura, Miwa; Ota, Takamasa; Kainuma, Kazuhisa; Sayre, James W.; McNitt-Gray, Michael; Katada, Kazuhiro
2008-01-01
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As reported in previous studies, edge-preserving adaptive image filters, which selectively eliminate only the noise elements that are increased when the radiation dose is reduced without affecting the sharpness of images, have been developed. In the present study, we employed receiver operating characteristic (ROC) analysis to assess the effects of the quantum denoising system (QDS), which is an edge-preserving adaptive filter that we have developed, on low-contrast resolution, and to evaluate to what degree the radiation dose can be reduced while maintaining acceptable low-contrast resolution. Materials and Methods. The low-contrast phantoms (Catphan 412) were scanned at various tube current settings, and ROC analysis was then performed for the groups of images obtained with/without the use of QDS at each tube current to determine whether or not a target could be identified. The tube current settings for which the area under the ROC curve (Az value) was approximately 0.7 were determined for both groups of images with/without the use of QDS. Then, the radiation dose reduction ratio when QDS was used was calculated by converting the determined tube current to the radiation dose. Results. The use of the QDS edge-preserving adaptive image filter allowed the radiation dose to be reduced by up to 38%. Conclusion. The QDS was found to be useful for reducing the radiation dose without affecting the low-contrast resolution in MSCT studies. PMID:19043565
Bittman, Jesse; Tam, Penny; Little, Chris; Khan, Nadia
2017-06-01
Handover of patients between care providers is a critical event in patient care. There is, however, little evidence to guide the handover process, including determining which patients to handover. Compare the ability of gestalt-based handover with two structured scores, the modified early warning score (MEWS) and our novel iHAND clinical decision support system, to predict which patients will be assessed by a physician overnight. This case-control study included 90 inpatients, comprising 32 patients assessed overnight (cases) and 58 patients not assessed overnight (controls) at a teaching hospital in British Columbia, Canada (May 2012). Gestalt, MEWS and iHAND scores were analysed against patients seen overnight using logistic regression and receiver-operating characteristic (ROC) curves. Neither current gestalt-based handover practice (odds ratio (OR) 1.50, 95% CI 0.89 to 3.83) nor MEWS (OR 0.96, 95% CI 0.75 to 1.24, area under the ROC curve (AUC) 0.61, 95% CI 0.49 to 0.73) were significantly associated with need to be seen overnight. The iHAND score was associated with need to be seen (OR 1.93, 95% CI 1.24 to 3.02, AUC 0.70, 95% CI 0.60 to 0.81). The iHAND score had moderate ability to predict which patients required assessment overnight, while MEWS score and current gestalt approach correlated poorly, suggesting the iHAND score may help prioritisation of patients likely to be seen overnight for handover. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
A comparison of ROC inferred from FROC and conventional ROC
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Littlefair, Stephen; Pietrzyk, Mariusz W.
2014-03-01
This study aims to determine whether receiver operating characteristic (ROC) scores inferred from free-response receiver operating characteristic (FROC) were equivalent to conventional ROC scores for the same readers and cases. Forty-five examining radiologists of the American Board of Radiology independently reviewed 47 PA chest radiographs under at least two conditions. Thirty-seven cases had abnormal findings and 10 cases had normal findings. Half the readers were asked to first locate any visualized lung nodules, mark them and assign a level of confidence [the FROC mark-rating pair] and second give an overall to the entire image on the same scale [the ROC score]. The second half of readers gave the ROC rating first followed by the FROC mark-rating pairs. A normal image was represented with number 1 and malignant lesions with numbers 2-5. A jackknife free-response receiver operating characteristic (JAFROC), and inferred ROC (infROC) was calculated from the mark-rating pairs using JAFROC V4.1 software. ROC based on the overall rating of the image calculated using DBM MRMC software, which was also used to compare infROC and ROC AUCs treating the methods as modalities. Pearson's correlations coefficient and linear regression were used to examine their relationship using SPSS, version 21.0; (SPSS, Chicago, IL). The results of this study showed no significant difference between the ROC and Inferred ROC AUCs (p≤0.25). While Pearson's correlation coefficient was 0.7 (p≤0.01). Inter-reader correlation calculated from Obuchowski- Rockette covariance's ranged from 0.43-0.86 while intra-reader agreement was greater than previously reported ranging from 0.68-0.82.
Aedes aegypti Larval Indices and Risk for Dengue Epidemics
Sanchez, Lizet; Vanlerberghe, Veerle; Alfonso, Lázara; Marquetti, María del Carmen; Guzman, María Guadalupe; Bisset, Juan; van der Stuyft, Patrick
2006-01-01
We assessed in a case-control study the test-validity of Aedes larval indices for the 2000 Havana outbreak. "Cases" were blocks where a dengue fever patient lived during the outbreak. "Controls" were randomly sampled blocks. Before, during, and after the epidemic, we calculated Breteau index (BI) and house index at the area, neighborhood, and block level. We constructed receiver operating characteristic (ROC) curves to determine their performance as predictors of dengue transmission. We observed a pronounced effect of the level of measurement. The BImax (maximum block BI in a radius of 100 m) at 2-month intervals had an area under the ROC curve of 71%. At a cutoff of 4.0, it significantly (odds ratio 6.00, p<0.05) predicted transmission with 78% sensitivity and 63% specificity. Analysis of BI at the local level, with human-defined boundaries, could be introduced in control programs to identify neighborhoods at high risk for dengue transmission. PMID:16704841
Integrated Radio and Optical Communication (iROC)
NASA Technical Reports Server (NTRS)
Raible, Daniel; Romanofsky, Robert; Pease, Gary; Kacpura, Thomas
2016-01-01
This is an overview of the Integrated Radio and Optical Communication (iROC) Project for Space Communication and Navigation Industry Days. The Goal is to develop and demonstrate new, high payoff space technologies that will promote mission utilization of optical communications, thereby expanding the capabilities of NASA's exploration, science, and discovery missions. This is an overview that combines the paramount features of select deep space RF and optical communications elements into an integrated system, scalable from deep space to near earth. It will realize Ka-band RF and 1550 nanometer optical capability. The approach is to prototype and demonstrate performance of key components to increase to TRL-5, leading to integrated hybrid communications system demonstration to increase to TRL-5, leading to integrated hybrid communications system demonstration.
A Study of the U.S. Foreign Military Sales and ROC (Republic of China) Procurement System
1988-09-01
representatives have long contact with American suppliers, and in a world in which the ROC no longer enjoys diplomatic recognition among the major suppliers, it ...THE FMS IN THE U.S. A. GENERAL Itt. United States Security Assistance Program is an important instrument for pursuing peace and world order. It has...been a cornerstone of postwar U.S. foreign polic~tt, and an integral part of its overall nat~onal security effort. In order to maintain a stable world
Wang, Xiaoman; Qian, Linxue; Jia, Liqun; Bellah, Richard; Wang, Ning; Xin, Yue; Liu, Qinglin
2016-07-01
The purpose of this study was to investigate the potential utility of shear wave elastography (SWE) for diagnosis of biliary atresia and for differentiating biliary atresia from infantile hepatitis syndrome by measuring liver stiffness. Thirty-eight patients with biliary atresia and 17 patients with infantile hepatitis syndrome were included, along with 31 healthy control infants. The 3 groups underwent SWE. The hepatic tissue of each patient with biliary atresia had been surgically biopsied. Statistical analyses for mean values of the 3 groups were performed. Optimum cutoff values using SWE for differentiation between the biliary atresia and control groups were calculated by a receiver operating characteristic (ROC) analysis. The mean SWE values ± SD for the 3 groups were as follows: biliary atresia group, 20.46 ± 10.19 kPa; infantile hepatitis syndrome group, 6.29 ± 0.99 kPa; and control group, 6.41 ± 1.08 kPa. The mean SWE value for the biliary atresia group was higher than the values for the control and infantile hepatitis syndrome groups (P < .01). The mean SWE values between the control and infantile hepatitis syndrome groups were not statistically different. The ROC analysis showed a cutoff value of 8.68 kPa for differentiation between the biliary atresia and control groups. The area under the ROC curve was 0.997, with sensitivity of 97.4%, specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 96.9%. Correlation analysis suggested a positive correlation between SWE values and age for patients with biliary atresia, with a Pearson correlation coefficient of 0.463 (P < .05). The significant increase in liver SWE values in neonates and infants with biliary atresia supports their application for differentiating biliary atresia from infantile hepatitis syndrome.
ROCS: a Reproducibility Index and Confidence Score for Interaction Proteomics Studies
2012-01-01
Background Affinity-Purification Mass-Spectrometry (AP-MS) provides a powerful means of identifying protein complexes and interactions. Several important challenges exist in interpreting the results of AP-MS experiments. First, the reproducibility of AP-MS experimental replicates can be low, due both to technical variability and the dynamic nature of protein interactions in the cell. Second, the identification of true protein-protein interactions in AP-MS experiments is subject to inaccuracy due to high false negative and false positive rates. Several experimental approaches can be used to mitigate these drawbacks, including the use of replicated and control experiments and relative quantification to sensitively distinguish true interacting proteins from false ones. Methods To address the issues of reproducibility and accuracy of protein-protein interactions, we introduce a two-step method, called ROCS, which makes use of Indicator Prey Proteins to select reproducible AP-MS experiments, and of Confidence Scores to select specific protein-protein interactions. The Indicator Prey Proteins account for measures of protein identifiability as well as protein reproducibility, effectively allowing removal of outlier experiments that contribute noise and affect downstream inferences. The filtered set of experiments is then used in the Protein-Protein Interaction (PPI) scoring step. Prey protein scoring is done by computing a Confidence Score, which accounts for the probability of occurrence of prey proteins in the bait experiments relative to the control experiment, where the significance cutoff parameter is estimated by simultaneously controlling false positives and false negatives against metrics of false discovery rate and biological coherence respectively. In summary, the ROCS method relies on automatic objective criterions for parameter estimation and error-controlled procedures. Results We illustrate the performance of our method by applying it to five previously published AP-MS experiments, each containing well characterized protein interactions, allowing for systematic benchmarking of ROCS. We show that our method may be used on its own to make accurate identification of specific, biologically relevant protein-protein interactions, or in combination with other AP-MS scoring methods to significantly improve inferences. Conclusions Our method addresses important issues encountered in AP-MS datasets, making ROCS a very promising tool for this purpose, either on its own or in conjunction with other methods. We anticipate that our methodology may be used more generally in proteomics studies and databases, where experimental reproducibility issues arise. The method is implemented in the R language, and is available as an R package called “ROCS”, freely available from the CRAN repository http://cran.r-project.org/. PMID:22682516
Connors, B M; Cooper, A B
2014-12-01
Categorization of the status of populations, species, and ecosystems underpins most conservation activities. Status is often based on how a system's current indicator value (e.g., change in abundance) relates to some threshold of conservation concern. Receiver operating characteristic (ROC) curves can be used to quantify the statistical reliability of indicators of conservation status and evaluate trade-offs between correct (true positive) and incorrect (false positive) classifications across a range of decision thresholds. However, ROC curves assume a discrete, binary relationship between an indicator and the conservation status it is meant to track, which is a simplification of the more realistic continuum of conservation status, and may limit the applicability of ROC curves in conservation science. We describe a modified ROC curve that treats conservation status as a continuum rather than a discrete state. We explored the influence of this continuum and typical sources of variation in abundance that can lead to classification errors (i.e., random variation and measurement error) on the true and false positive rates corresponding to varying decision thresholds and the reliability of change in abundance as an indicator of conservation status, respectively. We applied our modified ROC approach to an indicator of endangerment in Pacific salmon (Oncorhynchus nerka) (i.e., percent decline in geometric mean abundance) and an indicator of marine ecosystem structure and function (i.e., detritivore biomass). Failure to treat conservation status as a continuum when choosing thresholds for indicators resulted in the misidentification of trade-offs between true and false positive rates and the overestimation of an indicator's reliability. We argue for treating conservation status as a continuum when ROC curves are used to evaluate decision thresholds in indicators for the assessment of conservation status. © 2014 Society for Conservation Biology.
He, Xin; Frey, Eric C
2006-08-01
Previously, we have developed a decision model for three-class receiver operating characteristic (ROC) analysis based on decision theory. The proposed decision model maximizes the expected decision utility under the assumption that incorrect decisions have equal utilities under the same hypothesis (equal error utility assumption). This assumption reduced the dimensionality of the "general" three-class ROC analysis and provided a practical figure-of-merit to evaluate the three-class task performance. However, it also limits the generality of the resulting model because the equal error utility assumption will not apply for all clinical three-class decision tasks. The goal of this study was to investigate the optimality of the proposed three-class decision model with respect to several other decision criteria. In particular, besides the maximum expected utility (MEU) criterion used in the previous study, we investigated the maximum-correctness (MC) (or minimum-error), maximum likelihood (ML), and Nyman-Pearson (N-P) criteria. We found that by making assumptions for both MEU and N-P criteria, all decision criteria lead to the previously-proposed three-class decision model. As a result, this model maximizes the expected utility under the equal error utility assumption, maximizes the probability of making correct decisions, satisfies the N-P criterion in the sense that it maximizes the sensitivity of one class given the sensitivities of the other two classes, and the resulting ROC surface contains the maximum likelihood decision operating point. While the proposed three-class ROC analysis model is not optimal in the general sense due to the use of the equal error utility assumption, the range of criteria for which it is optimal increases its applicability for evaluating and comparing a range of diagnostic systems.
Wang, Xiao-Xiong; Wu, Yin-Hu; Zhang, Tian-Yuan; Xu, Xue-Qiao; Dao, Guo-Hua; Hu, Hong-Ying
2016-05-01
While reverse osmosis (RO) is a promising technology for wastewater reclamation, RO concentrate (ROC) treatment and disposal are important issues to consider. Conventional chemical and physical treatment methods for ROC present certain limitations, such as relatively low nitrogen and phosphorus removal efficiencies as well as the requirement of an extra process for hardness removal. This study proposes a novel biological approach for simultaneous removal of nitrogen, phosphorus, and calcium (Ca(2+)) and magnesium (Mg(2+)) ions from the ROC of municipal wastewater treatment plants by microalgal cultivation and algal biomass production. Two microalgae strains, Chlorella sp. ZTY4 and Scenedesmus sp. LX1, were used for batch cultivation of 14-16 days. Both strains grew well in ROC with average biomass production of 318.7 mg/L and lipid contents up to 30.6%, and nitrogen and phosphorus could be effectively removed with efficiencies of up to 89.8% and 92.7%, respectively. Approximately 55.9%-83.7% Ca(2+) could be removed from the system using the cultured strains. Mg(2+) removal began when Ca(2+) precipitation ceased, and the removal efficiency of the ion could reach up to 56.0%. The most decisive factor influencing Ca(2+) and Mg(2+) removal was chemical precipitation with increases in pH caused by algal growth. The results of this study provide a new biological approach for removing nitrogen, phosphorous, and hardness from ROC. The results suggest that microalgal cultivation presents new opportunities for applying an algal process to ROC treatment. The proposed approach serves dual purposes of nutrient and hardness reduction and production of lipid rich micro-algal biomass. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio
2009-01-01
Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510
Determination of glucose-6-phosphate dehydrogenase cut-off values in a Tunisian population.
Laouini, Naouel; Sahli, Chaima Abdelhafidh; Jouini, Latifa; Haloui, Sabrine; Fredj, Sondes Hadj; Daboubi, Rym; Siala, Hajer; Ouali, Faida; Becher, Meriam; Toumi, Nourelhouda; Bibi, Amina; Messsaoud, Taieb
2017-07-26
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the commonest enzymopathy worldwide. The incidence depends essentially on the methods used for the assessment. In this respect, we attempted in this study to set cut-off values of G6PD activity to discriminate among normal, heterozygous, and deficient individuals using the World Health Organization (WHO) classification and the receiver operating characteristics (ROC) curve analysis. Blood samples from 250 female and 302 male subjects were enrolled in this study. The G6PD activity was determined using a quantitative assay. The common G6PD mutations in Tunisia were determined using the amplification refractory mutation system (ARMS-PCR) method. The ROC curve was used to choice the best cut-off. Normal G6PD values were 7.69±2.37, 7.86±2.39, and 7.51±2.35 U/g Hb for the entire, male, and female groups, respectively. Cut-off values for the total, male, and female were determined using the WHO classification and ROC curves analysis. In the male population, both cut-offs established using ROC curve analysis (4.00 U/g Hb) and the 60% level (3.82 U/g Hb), respectively are sensitive and specific resulting in a good efficiency of discrimination between deficient and normal males. For the female group the ROC cut-off (5.84 U/g Hb) seems better than the 60% level cut-off (3.88 U/g Hb) to discriminate between normal and heterozygote or homozygote women with higher Youden Index. The establishment of the normal values for a population is important for a better evaluation of the assay result. The ROC curve analysis is an alternative method to determine the status of patients since it correlates DNA analysis and G6PD activity.
Validating a biometric authentication system: sample size requirements.
Dass, Sarat C; Zhu, Yongfang; Jain, Anil K
2006-12-01
Authentication systems based on biometric features (e.g., fingerprint impressions, iris scans, human face images, etc.) are increasingly gaining widespread use and popularity. Often, vendors and owners of these commercial biometric systems claim impressive performance that is estimated based on some proprietary data. In such situations, there is a need to independently validate the claimed performance levels. System performance is typically evaluated by collecting biometric templates from n different subjects, and for convenience, acquiring multiple instances of the biometric for each of the n subjects. Very little work has been done in 1) constructing confidence regions based on the ROC curve for validating the claimed performance levels and 2) determining the required number of biometric samples needed to establish confidence regions of prespecified width for the ROC curve. To simplify the analysis that address these two problems, several previous studies have assumed that multiple acquisitions of the biometric entity are statistically independent. This assumption is too restrictive and is generally not valid. We have developed a validation technique based on multivariate copula models for correlated biometric acquisitions. Based on the same model, we also determine the minimum number of samples required to achieve confidence bands of desired width for the ROC curve. We illustrate the estimation of the confidence bands as well as the required number of biometric samples using a fingerprint matching system that is applied on samples collected from a small population.
Yoon, Jung Won; Shin, Youn Ho; Jee, Hye Mi; Chang, Sun Jung; Baek, Ji Hyeon; Choi, Sun Hee; Kim, Hyeong Yun; Han, Man Yong
2014-06-01
There are few studies focusing on the comparison of resistance (Rrs) and reactance (Xrs) in impulse oscillometry system (IOS) in the bronchial challenge test using dose-response slope (DRS), a quantitative index of bronchial hyperresponsiveness. We conducted a case-control study of 144 asthmatic and 218 non-asthmatic children to compare the diagnostic accuracy of two-point linear DRS for FEV1 , Rrs5 , and Xrs5 (DRS_FEV1 , DRS_Rrs5 , and DRS_Xrs5 ) and assessed various diagnostic cut-off points of provocation concentrations (PC) using receiver operating characteristic (ROC) curves. DRS_FEV1 had a stronger correlation with DRS_Xrs5 (r = 0.739, P < 0.001) than with DRS_Rrs5 (r = 0.652, P < 0.001) and the area under the ROC curves of DRS_Xrs5 (0.737) was similar to that of DRS_FEV1 (0.732) and higher than that of DRS_Rrs5 (0.668). The area under the ROC curves in order of greater value was as follows: absolute change of Xrs5 (Abs_Xrs5 ) (0.759) > percent change of FEV1 (Pch_FEV1 ) (0.735) > Pch_Xrs5 (0.727) > Abs_Rrs5 (0.690) > Pch_Rrs5 (0.630). PC78 _Xrs5 and PC0.17 _Xrs5 of IOS showed considerably good sensitivity and specificity comparable to those of PC20 _FEV1 by spirometry. Additional 18 (13%) children who showed normal spirometric measures were identified as asthmatics with the use of IOS. The utility of the DRS_Xrs5 to differentiate asthmatics from controls was comparable to that of the DRS_FEV1 and better than that of the DRS_Rrs5 . In addition, IOS could detect additional asthmatic patients who did not show positive responses in spirometry. © 2013 Wiley Periodicals, Inc.
Mikula, Anthony L; Williams, Seth K; Anderson, Paul A
2016-04-01
Insertion of instruments or implants into the spine carries a risk for injury to neural tissue. Triggered electromyography (tEMG) is an intraoperative neuromonitoring technique that involves electrical stimulation of a tool or screw and subsequent measurement of muscle action potentials from myotomes innervated by nerve roots near the stimulated instrument. The authors of this study sought to determine the ability of tEMG to detect misplaced pedicle screws (PSs). The authors searched the U.S. National Library of Medicine, the Web of Science Core Collection database, and the Cochrane Central Register of Controlled Trials for PS studies. A meta-analysis of these studies was performed on a per-screw basis to determine the ability of tEMG to detect misplaced PSs. Sensitivity, specificity, and receiver operating characteristic (ROC) area under the curve (AUC) were calculated overall and in subgroups. Twenty-six studies were included in the systematic review. The authors analyzed 18 studies in which tEMG was used during PS placement in the meta-analysis, representing data from 2932 patients and 15,065 screws. The overall sensitivity of tEMG for detecting misplaced PSs was 0.78, and the specificity was 0.94. The overall ROC AUC was 0.96. A tEMG current threshold of 10-12 mA (ROC AUC 0.99) and a pulse duration of 300 µsec (ROC AUC 0.97) provided the most accurate testing parameters for detecting misplaced screws. Screws most accurately conducted EMG signals (ROC AUC 0.98). Triggered electromyography has very high specificity but only fair sensitivity for detecting malpositioned PSs.
Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.
Honaker, Julie A; Shepard, Neil T
2011-01-01
Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.
[Value of sepsis single-disease manage system in predicting mortality in patients with sepsis].
Chen, J; Wang, L H; Ouyang, B; Chen, M Y; Wu, J F; Liu, Y J; Liu, Z M; Guan, X D
2018-04-03
Objective: To observe the effect of sepsis single-disease manage system on the improvement of sepsis treatment and the value in predicting mortality in patients with sepsis. Methods: A retrospective study was conducted. Patients with sepsis admitted to the Department of Surgical Intensive Care Unit of Sun Yat-Sen University First Affiliated Hospital from September 22, 2013 to May 5, 2015 were enrolled in this study. Sepsis single-disease manage system (Rui Xin clinical data manage system, China data, China) was used to monitor 25 clinical quality parameters, consisting of timeliness, normalization and outcome parameters. Based on whether these quality parameters could be completed or not, the clinical practice was evaluated by the system. The unachieved quality parameter was defined as suspicious parameters, and these suspicious parameters were used to predict mortality of patients with receiver operating characteristic curve (ROC). Results: A total of 1 220 patients with sepsis were enrolled, included 805 males and 415 females. The mean age was (59±17) years, and acute physiology and chronic health evaluation (APACHE Ⅱ) scores was 19±8. The area under ROC curve of total suspicious numbers for predicting 28-day mortality was 0.70; when the suspicious parameters number was more than 6, the sensitivity was 68.0% and the specificity was 61.0% for predicting 28-day mortality. In addition, the area under ROC curve of outcome suspicious number for predicting 28-day mortality was 0.89; when the suspicious outcome parameters numbers was more than 1, the sensitivity was 88.0% and the specificity was 78.0% for predicting 28-day mortality. Moreover, the area under ROC curve of total suspicious number for predicting 90-day mortality was 0.73; when the total suspicious parameters number was more than 7, the sensitivity was 60.0% and the specificity was 74.0% for predicting 90-day mortality. Finally, the area under ROC curve of outcome suspicious numbers for predicting 90-day mortality was 0.92; when suspicious outcome parameters numbers was more than 1, the sensitivity was 88.0% and the specificity was 81.0% for predicting 90-day mortality. Conclusion: The single center study suggests that this sepsis single-disease manage system could be used to monitor the completion of clinical practice for intensivist in managing sepsis, and the number of quality parameters failed to complete could be used to predict the mortality of the patients.
Nardo, Luciano G; Gelbaya, Tarek A; Wilkinson, Hannah; Roberts, Stephen A; Yates, Allen; Pemberton, Phil; Laing, Ian
2009-11-01
To evaluate the clinical value of basal anti-Müllerian hormone (AMH) measurements compared with other available determinants, apart from chronologic age, in the prediction of ovarian response to gonadotrophin stimulation. Prospective cohort study. Tertiary referral center for reproductive medicine and an IVF unit. Women undergoing their first cycle of controlled ovarian hyperstimulation (COH) for in vitro fertilization (IVF). Basal levels of FSH and AMH as well as antral follicle count (AFC) were measured in 165 subjects. All patients were followed prospectively and their cycle outcomes recorded. Predictive value of FSH, AMH, and AFC for extremes of ovarian response to stimulation. Out of the 165 women, 134 were defined as normal responders, 15 as poor responders, and 16 as high responders. Subjects in the poor response group were significantly older then those in the other two groups. Anti-Müllerian hormone levels and AFC were markedly raised in the high responders and decreased in the poor responders. Compared with FSH and AFC, AMH performed better in the prediction of excessive response to ovarian stimulation-AMH area under receiver operating characteristic curve (ROC(AUC)) 0.81, FSH ROC(AUC) 0.66, AFC ROC(AUC) 0.69. For poor response, AMH (ROC(AUC) 0.88) was a significantly better predictor than FSH (ROC(AUC) 0.63) but not AFC (ROC(AUC) 0.81). AMH prediction of ovarian response was independent of age and PCOS. Anti-Müllerian hormone cutoffs of >3.75 ng/mL and <1.0 ng/mL would have modest sensitivity and specificity in predicting the extremes of response. Circulating AMH has the ability to predict excessive and poor response to stimulation with exogenous gonadotrophins. Overall, this biomarker is superior to basal FSH and AFC, and has the potential to be incorporated in to work-up protocols to predict patient's ovarian response to treatment and to individualize strategies aiming at reducing the cancellation rate and the iatrogenic complications of COH.
Mutations in the LRRK2 Roc-COR tandem domain link Parkinson's disease to Wnt signalling pathways.
Sancho, Rosa M; Law, Bernard M H; Harvey, Kirsten
2009-10-15
Mutations in PARK8, encoding LRRK2, are the most common known cause of Parkinson's disease. The LRRK2 Roc-COR tandem domain exhibits GTPase activity controlling LRRK2 kinase activity via an intramolecular process. We report the interaction of LRRK2 with the dishevelled family of phosphoproteins (DVL1-3), key regulators of Wnt (Wingless/Int) signalling pathways important for axon guidance, synapse formation and neuronal maintenance. Interestingly, DVLs can interact with and mediate the activation of small GTPases with structural similarity to the LRRK2 Roc domain. The LRRK2 Roc-COR domain and the DVL1 DEP domain were necessary and sufficient for LRRK2-DVL1 interaction. Co-expression of DVL1 increased LRRK2 steady-state protein levels, an effect that was dependent on the DEP domain. Strikingly, LRRK2-DVL1-3 interactions were disrupted by the familial PARK8 mutation Y1699C, whereas pathogenic mutations at residues R1441 and R1728 strengthened LRRK2-DVL1 interactions. Co-expression of DVL1 with LRRK2 in mammalian cells resulted in the redistribution of LRRK2 to typical cytoplasmic DVL1 aggregates in HEK293 and SH-SY5Y cells and co-localization in neurites and growth cones of differentiated dopaminergic SH-SY5Y cells. This is the first report of the modulation of a key LRRK2-accessory protein interaction by PARK8 Roc-COR domain mutations segregating with Parkinson's disease. Since the DVL1 DEP domain is known to be involved in the regulation of small GTPases, we propose that: (i) DVLs may influence LRRK2 GTPase activity, and (ii) Roc-COR domain mutations modulating LRRK2-DVL interactions indirectly influence kinase activity. Our findings also link LRRK2 to Wnt signalling pathways, suggesting novel pathogenic mechanisms and new targets for genetic analysis in Parkinson's disease.
Mutations in the LRRK2 Roc-COR tandem domain link Parkinson's disease to Wnt signalling pathways
Sancho, Rosa M.; Law, Bernard M.H.; Harvey, Kirsten
2009-01-01
Mutations in PARK8, encoding LRRK2, are the most common known cause of Parkinson's disease. The LRRK2 Roc-COR tandem domain exhibits GTPase activity controlling LRRK2 kinase activity via an intramolecular process. We report the interaction of LRRK2 with the dishevelled family of phosphoproteins (DVL1-3), key regulators of Wnt (Wingless/Int) signalling pathways important for axon guidance, synapse formation and neuronal maintenance. Interestingly, DVLs can interact with and mediate the activation of small GTPases with structural similarity to the LRRK2 Roc domain. The LRRK2 Roc-COR domain and the DVL1 DEP domain were necessary and sufficient for LRRK2–DVL1 interaction. Co-expression of DVL1 increased LRRK2 steady-state protein levels, an effect that was dependent on the DEP domain. Strikingly, LRRK2–DVL1-3 interactions were disrupted by the familial PARK8 mutation Y1699C, whereas pathogenic mutations at residues R1441 and R1728 strengthened LRRK2–DVL1 interactions. Co-expression of DVL1 with LRRK2 in mammalian cells resulted in the redistribution of LRRK2 to typical cytoplasmic DVL1 aggregates in HEK293 and SH-SY5Y cells and co-localization in neurites and growth cones of differentiated dopaminergic SH-SY5Y cells. This is the first report of the modulation of a key LRRK2-accessory protein interaction by PARK8 Roc-COR domain mutations segregating with Parkinson's disease. Since the DVL1 DEP domain is known to be involved in the regulation of small GTPases, we propose that: (i) DVLs may influence LRRK2 GTPase activity, and (ii) Roc-COR domain mutations modulating LRRK2–DVL interactions indirectly influence kinase activity. Our findings also link LRRK2 to Wnt signalling pathways, suggesting novel pathogenic mechanisms and new targets for genetic analysis in Parkinson's disease. PMID:19625296
Froud, Robert; Abel, Gary
2014-01-01
Background Receiver Operator Characteristic (ROC) curves are being used to identify Minimally Important Change (MIC) thresholds on scales that measure a change in health status. In quasi-continuous patient reported outcome measures, such as those that measure changes in chronic diseases with variable clinical trajectories, sensitivity and specificity are often valued equally. Notwithstanding methodologists agreeing that these should be valued equally, different approaches have been taken to estimating MIC thresholds using ROC curves. Aims and objectives We aimed to compare the different approaches used with a new approach, exploring the extent to which the methods choose different thresholds, and considering the effect of differences on conclusions in responder analyses. Methods Using graphical methods, hypothetical data, and data from a large randomised controlled trial of manual therapy for low back pain, we compared two existing approaches with a new approach that is based on the addition of the sums of squares of 1-sensitivity and 1-specificity. Results There can be divergence in the thresholds chosen by different estimators. The cut-point selected by different estimators is dependent on the relationship between the cut-points in ROC space and the different contours described by the estimators. In particular, asymmetry and the number of possible cut-points affects threshold selection. Conclusion Choice of MIC estimator is important. Different methods for choosing cut-points can lead to materially different MIC thresholds and thus affect results of responder analyses and trial conclusions. An estimator based on the smallest sum of squares of 1-sensitivity and 1-specificity is preferable when sensitivity and specificity are valued equally. Unlike other methods currently in use, the cut-point chosen by the sum of squares method always and efficiently chooses the cut-point closest to the top-left corner of ROC space, regardless of the shape of the ROC curve. PMID:25474472
Discriminability of personality profiles in isolated and Co-morbid marijuana and nicotine users.
Ketcherside, Ariel; Jeon-Slaughter, Haekyung; Baine, Jessica L; Filbey, Francesca M
2016-04-30
Specific personality traits have been linked with substance use disorders (SUDs), genetic mechanisms, and brain systems. Thus, determining the specificity of personality traits to types of SUD can advance the field towards defining SUD endophenotypes as well as understanding the brain systems involved for the development of novel treatments. Disentangling these factors is particularly important in highly co morbid SUDs, such as marijuana and nicotine use, so treatment can occur effectively for both. This study evaluated personality traits that distinguish isolated and co-morbid use of marijuana and nicotine. To that end, we collected the NEO Five Factor Inventory in participants who used marijuana-only (n=59), nicotine-only (n=27), both marijuana and nicotine (n=28), and in non-using controls (n=28). We used factor analyses to identify personality profiles, which are linear combinations of the five NEO Factors. We then conducted Receiver Operating Characteristics (ROC) curve analysis to test accuracy of the personality factors in discriminating isolated and co-morbid marijuana and nicotine users from each other. ROC curve analysis distinguished the four groups based on their NEO personality patterns. Results showed that NEO Factor 2 (openness, extraversion, agreeableness) discriminated marijuana and marijuana+nicotine users from controls and nicotine-only users with high predictability. Additional ANOVA results showed that the openness dimension discriminated marijuana users from nicotine users. These findings suggest that personality dimensions distinguish marijuana users from nicotine users and should be considered in prevention strategies. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Developing a clinical utility framework to evaluate prediction models in radiogenomics
NASA Astrophysics Data System (ADS)
Wu, Yirong; Liu, Jie; Munoz del Rio, Alejandro; Page, David C.; Alagoz, Oguzhan; Peissig, Peggy; Onitilo, Adedayo A.; Burnside, Elizabeth S.
2015-03-01
Combining imaging and genetic information to predict disease presence and behavior is being codified into an emerging discipline called "radiogenomics." Optimal evaluation methodologies for radiogenomics techniques have not been established. We aim to develop a clinical decision framework based on utility analysis to assess prediction models for breast cancer. Our data comes from a retrospective case-control study, collecting Gail model risk factors, genetic variants (single nucleotide polymorphisms-SNPs), and mammographic features in Breast Imaging Reporting and Data System (BI-RADS) lexicon. We first constructed three logistic regression models built on different sets of predictive features: (1) Gail, (2) Gail+SNP, and (3) Gail+SNP+BI-RADS. Then, we generated ROC curves for three models. After we assigned utility values for each category of findings (true negative, false positive, false negative and true positive), we pursued optimal operating points on ROC curves to achieve maximum expected utility (MEU) of breast cancer diagnosis. We used McNemar's test to compare the predictive performance of the three models. We found that SNPs and BI-RADS features augmented the baseline Gail model in terms of the area under ROC curve (AUC) and MEU. SNPs improved sensitivity of the Gail model (0.276 vs. 0.147) and reduced specificity (0.855 vs. 0.912). When additional mammographic features were added, sensitivity increased to 0.457 and specificity to 0.872. SNPs and mammographic features played a significant role in breast cancer risk estimation (p-value < 0.001). Our decision framework comprising utility analysis and McNemar's test provides a novel framework to evaluate prediction models in the realm of radiogenomics.
On the convexity of ROC curves estimated from radiological test results.
Pesce, Lorenzo L; Metz, Charles E; Berbaum, Kevin S
2010-08-01
Although an ideal observer's receiver operating characteristic (ROC) curve must be convex-ie, its slope must decrease monotonically-published fits to empirical data often display "hooks." Such fits sometimes are accepted on the basis of an argument that experiments are done with real, rather than ideal, observers. However, the fact that ideal observers must produce convex curves does not imply that convex curves describe only ideal observers. This article aims to identify the practical implications of nonconvex ROC curves and the conditions that can lead to empirical or fitted ROC curves that are not convex. This article views nonconvex ROC curves from historical, theoretical, and statistical perspectives, which we describe briefly. We then consider population ROC curves with various shapes and analyze the types of medical decisions that they imply. Finally, we describe how sampling variability and curve-fitting algorithms can produce ROC curve estimates that include hooks. We show that hooks in population ROC curves imply the use of an irrational decision strategy, even when the curve does not cross the chance line, and therefore usually are untenable in medical settings. Moreover, we sketch a simple approach to improve any nonconvex ROC curve by adding statistical variation to the decision process. Finally, we sketch how to test whether hooks present in ROC data are likely to have been caused by chance alone and how some hooked ROCs found in the literature can be easily explained as fitting artifacts or modeling issues. In general, ROC curve fits that show hooks should be looked on with suspicion unless other arguments justify their presence. 2010 AUR. Published by Elsevier Inc. All rights reserved.
On the convexity of ROC curves estimated from radiological test results
Pesce, Lorenzo L.; Metz, Charles E.; Berbaum, Kevin S.
2010-01-01
Rationale and Objectives Although an ideal observer’s receiver operating characteristic (ROC) curve must be convex — i.e., its slope must decrease monotonically — published fits to empirical data often display “hooks.” Such fits sometimes are accepted on the basis of an argument that experiments are done with real, rather than ideal, observers. However, the fact that ideal observers must produce convex curves does not imply that convex curves describe only ideal observers. This paper aims to identify the practical implications of non-convex ROC curves and the conditions that can lead to empirical and/or fitted ROC curves that are not convex. Materials and Methods This paper views non-convex ROC curves from historical, theoretical and statistical perspectives, which we describe briefly. We then consider population ROC curves with various shapes and analyze the types of medical decisions that they imply. Finally, we describe how sampling variability and curve-fitting algorithms can produce ROC curve estimates that include hooks. Results We show that hooks in population ROC curves imply the use of an irrational decision strategy, even when the curve doesn’t cross the chance line, and therefore usually are untenable in medical settings. Moreover, we sketch a simple approach to improve any non-convex ROC curve by adding statistical variation to the decision process. Finally, we sketch how to test whether hooks present in ROC data are likely to have been caused by chance alone and how some hooked ROCs found in the literature can be easily explained as fitting artifacts or modeling issues. Conclusion In general, ROC curve fits that show hooks should be looked upon with suspicion unless other arguments justify their presence. PMID:20599155
Brown Connolly, Nancy E
2014-12-01
This foundational study applies the process of receiver operating characteristic (ROC) analysis to evaluate utility and predictive value of a disease management (DM) model that uses RM devices for chronic obstructive pulmonary disease (COPD). The literature identifies a need for a more rigorous method to validate and quantify evidence-based value for remote monitoring (RM) systems being used to monitor persons with a chronic disease. ROC analysis is an engineering approach widely applied in medical testing, but that has not been evaluated for its utility in RM. Classifiers (saturated peripheral oxygen [SPO2], blood pressure [BP], and pulse), optimum threshold, and predictive accuracy are evaluated based on patient outcomes. Parametric and nonparametric methods were used. Event-based patient outcomes included inpatient hospitalization, accident and emergency, and home health visits. Statistical analysis tools included Microsoft (Redmond, WA) Excel(®) and MedCalc(®) (MedCalc Software, Ostend, Belgium) version 12 © 1993-2013 to generate ROC curves and statistics. Persons with COPD were monitored a minimum of 183 days, with at least one inpatient hospitalization within 12 months prior to monitoring. Retrospective, de-identified patient data from a United Kingdom National Health System COPD program were used. Datasets included biometric readings, alerts, and resource utilization. SPO2 was identified as a predictive classifier, with an optimal average threshold setting of 85-86%. BP and pulse were failed classifiers, and areas of design were identified that may improve utility and predictive capacity. Cost avoidance methodology was developed. RESULTS can be applied to health services planning decisions. Methods can be applied to system design and evaluation based on patient outcomes. This study validated the use of ROC in RM program evaluation.
Evolution of a Common Controller
2012-04-01
focused on distribution but with the same design concepts used in MOCU. Remote Operator Control Services (ROCS) will use an HTML5 enabled browser to...provide the presentation layer. HTML5 and WebGL provide most of the capability provided within MOCU 3 but in a standardized format. Data is
Diagnostic value of the plasmatic ADM level for early ectopic pregnancy.
Yan, Qi; Lu, Qi; Tao, Yu; Wang, Yu-Dong; Zhao, Wen-Xia
2015-01-01
To analyze the plasmatic ADM level in early pregnancy and to investigate the diagnostic value of ADM in early ectopic pregnancy (EP). 70 patients with EP who had menopause for 5~8 weeks were included as study group, while 155 women with normal intrauterine pregnancy were also included as control group. The correlation between ADM level and menopause weeks was statistically analyzed and ROC curve was used to identify the diagnostic value of ADM. (1) In 155 cases of normal intrauterine pregnancy, the plasmatic ADM level was increased with menopause weeks in linear relationship, and the correlation coefficient (R) was 0.991 (P<0.05). In 70 patients with EP, no significant increase was found with menopause weeks and no linear relationship can be found between ADM level and menopause weeks in EP group. The correlation coefficient (R) was 0.744 (P>0.05). (2) The multiple of median of plasmatic ADM level in EP group of menopause for 8 weeks was obviously lower than the intrauterine control group (P<0.01). (3) ROC curve was used to analyze the cut-off value of ADM level in the diagnosis of EP, and the area under the ROC curve was 0.523 (P>0.05) regardless of menopause weeks, however, the area under the ROC curve was 0.702 (P<0.05) at 8 weeks after menopause with sensitivity of 53.50% and specificity of 85.00%. Different from normal intrauterine pregnancy, plasmatic ADM level in early EP was relatively lower and no significant increase was found with menopause weeks; further studies are still needed for plasmatic ADM level as an indicator in the early diagnosis of EP.
Aslan, Kerim; Gunbey, Hediye Pinar; Tomak, Leman; Ozmen, Zafer; Incesu, Lutfi
The aim of this study was to investigate whether the use of combination quantitative metrics (mamillopontine distance [MPD], pontomesencephalic angle, and mesencephalon anterior-posterior/medial-lateral diameter ratios) with qualitative signs (dural enhancement, subdural collections/hematoma, venous engorgement, pituitary gland enlargements, and tonsillar herniations) provides a more accurate diagnosis of intracranial hypotension (IH). The quantitative metrics and qualitative signs of 34 patients and 34 control subjects were assessed by 2 independent observers. Receiver operating characteristic (ROC) curve was used to evaluate the diagnostic performance of quantitative metrics and qualitative signs, and for the diagnosis of IH, optimum cutoff values of quantitative metrics were found with ROC analysis. Combined ROC curve was measured for the quantitative metrics, and qualitative signs combinations in determining diagnostic accuracy and sensitivity, specificity, and positive and negative predictive values were found, and the best model combination was formed. Whereas MPD and pontomesencephalic angle were significantly lower in patients with IH when compared with the control group (P < 0.001), mesencephalon anterior-posterior/medial-lateral diameter ratio was significantly higher (P < 0.001). For qualitative signs, the highest individual distinctive power was dural enhancement with area under the ROC curve (AUC) of 0.838. For quantitative metrics, the highest individual distinctive power was MPD with AUC of 0.947. The best accuracy in the diagnosis of IH was obtained by combination of dural enhancement, venous engorgement, and MPD with an AUC of 1.00. This study showed that the combined use of dural enhancement, venous engorgement, and MPD had diagnostic accuracy of 100 % for the diagnosis of IH. Therefore, a more accurate IH diagnosis can be provided with combination of quantitative metrics with qualitative signs.
Mossman, Douglas
2013-01-01
The last two decades have witnessed major changes in the way that mental health professionals assess, describe, and think about persons' risk for future violence. Psychiatrists and psychologists have gone from believing that they could not predict violence to feeling certain they can assess violence risk with well-above-chance accuracy. Receiver operating characteristic (ROC) analysis has played a central role in changing this view. This article reviews the key concepts underlying ROC methods, the meaning of the area under the ROC curve (AUC), the relationship between AUC and effect size d, and what these two indices tell us about evaluations of violence risk. The area under the ROC curve and d provide succinct but incomplete descriptions of discrimination capacity. These indices do not provide details about sensitivity-specificity trade-offs; they do not tell us how to balance false-positive and false-negative errors; and they do not determine whether a diagnostic system is accurate enough to make practically useful distinctions between violent and non-violent subject groups. Justifying choices or clinical practices requires a contextual investigation of outcomes, a process that takes us beyond simply knowing global indices of accuracy. Copyright © 2013 John Wiley & Sons, Ltd.
Comparison of Paired ROC Curves through a Two-Stage Test.
Yu, Wenbao; Park, Eunsik; Chang, Yuan-Chin Ivan
2015-01-01
The area under the receiver operating characteristic (ROC) curve (AUC) is a popularly used index when comparing two ROC curves. Statistical tests based on it for analyzing the difference have been well developed. However, this index is less informative when two ROC curves cross and have similar AUCs. In order to detect differences between ROC curves in such situations, a two-stage nonparametric test that uses a shifted area under the ROC curve (sAUC), along with AUCs, is proposed for paired designs. The new procedure is shown, numerically, to be effective in terms of power under a wide range of scenarios; additionally, it outperforms two conventional ROC-type tests, especially when two ROC curves cross each other and have similar AUCs. Larger sAUC implies larger partial AUC at the range of low false-positive rates in this case. Because high specificity is important in many classification tasks, such as medical diagnosis, this is an appealing characteristic. The test also implicitly analyzes the equality of two commonly used binormal ROC curves at every operating point. We also apply the proposed method to synthesized data and two real examples to illustrate its usefulness in practice.
Relationship between vitamin D and glycemic control in patients with type 2 diabetes mellitus.
Olt, Serdar
2015-01-01
Herein I investigated the impact of vitamin D on glycemic control in patients with type 2 diabetes mellitus. 128 patients with type 2 diabetes mellitus were enrolled in this study (mean (S.D) age: 57.7±10 years, 26.6% were female). It was collected clinical and laboratory characteristics of patients from hospital records retrospectively. Patients were divided into two groups according to the HBA1c values: good glycemic control (HbA1c≤7%) and poor glycemic control (HbA1c>7%). It was compared 25 hydroxyvitamin (OH) D and other collected laboratory parameters between the two groups. The vitamin D deficiency rate was 98.3%. In the result with ROC curve analyzes and Mann Whitney U test vitamin D was'nt significantly associated with glycemic control (P value >0.05). Among other parameters result with ROC curve analyzes and student t test RDW-CV was found to be significantly associated with glycemic control (P value <0.05). Although high level of vitamin D deficiency, present study indicated that vitamin D was'nt significantly related to glycemic control in type 2 diyabetes mellitus. Even so RDW-CV was significantly related to glycemic control.
Relationship between vitamin D and glycemic control in patients with type 2 diabetes mellitus
Olt, Serdar
2015-01-01
Herein I investigated the impact of vitamin D on glycemic control in patients with type 2 diabetes mellitus. 128 patients with type 2 diabetes mellitus were enrolled in this study (mean (S.D) age: 57.7±10 years, 26.6% were female). It was collected clinical and laboratory characteristics of patients from hospital records retrospectively. Patients were divided into two groups according to the HBA1c values: good glycemic control (HbA1c≤7%) and poor glycemic control (HbA1c>7%). It was compared 25 hydroxyvitamin (OH) D and other collected laboratory parameters between the two groups. The vitamin D deficiency rate was 98.3%. In the result with ROC curve analyzes and Mann Whitney U test vitamin D was’nt significantly associated with glycemic control (P value >0.05). Among other parameters result with ROC curve analyzes and student t test RDW-CV was found to be significantly associated with glycemic control (P value <0.05). Although high level of vitamin D deficiency, present study indicated that vitamin D was’nt significantly related to glycemic control in type 2 diyabetes mellitus. Even so RDW-CV was significantly related to glycemic control. PMID:26770553
Tighe, Patrick J.; Harle, Christopher A.; Hurley, Robert W.; Aytug, Haldun; Boezaart, Andre P.; Fillingim, Roger B.
2015-01-01
Background Given their ability to process highly dimensional datasets with hundreds of variables, machine learning algorithms may offer one solution to the vexing challenge of predicting postoperative pain. Methods Here, we report on the application of machine learning algorithms to predict postoperative pain outcomes in a retrospective cohort of 8071 surgical patients using 796 clinical variables. Five algorithms were compared in terms of their ability to forecast moderate to severe postoperative pain: Least Absolute Shrinkage and Selection Operator (LASSO), gradient-boosted decision tree, support vector machine, neural network, and k-nearest neighbor, with logistic regression included for baseline comparison. Results In forecasting moderate to severe postoperative pain for postoperative day (POD) 1, the LASSO algorithm, using all 796 variables, had the highest accuracy with an area under the receiver-operating curve (ROC) of 0.704. Next, the gradient-boosted decision tree had an ROC of 0.665 and the k-nearest neighbor algorithm had an ROC of 0.643. For POD 3, the LASSO algorithm, using all variables, again had the highest accuracy, with an ROC of 0.727. Logistic regression had a lower ROC of 0.5 for predicting pain outcomes on POD 1 and 3. Conclusions Machine learning algorithms, when combined with complex and heterogeneous data from electronic medical record systems, can forecast acute postoperative pain outcomes with accuracies similar to methods that rely only on variables specifically collected for pain outcome prediction. PMID:26031220
Platelet count and platelet indices in women with preeclampsia.
AlSheeha, Muneera A; Alaboudi, Rafi S; Alghasham, Mohammad A; Iqbal, Javed; Adam, Ishag
2016-01-01
Although the exact pathophysiology of preeclampsia is not completely understood, the utility of different platelets indices can be utilized to predict preeclampsia. To compare platelet indices, namely platelet count (PC), mean platelet volume (MPV), platelet distribution width (PDW), and PC to MPV ratio in women with preeclampsia compared with healthy controls. Qassim Hospital, Kingdom of Saudi Arabia. A case-control study. Sixty preeclamptic women were the cases and an equal number of healthy pregnant women were the controls. There was no significant difference in age, parity, and body mass index between the study groups. Sixteen and 44 of the cases were severe and mild preeclampsia, respectively. There was no significant difference in PDW and MPV between the preeclamptic and control women. Both PC and PC to MPV ratios were significantly lower in the women with preeclampsia compared with the controls. There was no significant difference in the PC, PDW, MPV, and PC to MPV ratio when women with mild and severe preeclampsia were compared. Using receiver operating characteristic (ROC) curves, the PC cutoff was 248.0×10 3 /µL for diagnosis of pre-eclampsia ( P =0.019; the area under the ROC curve was 62.4%). Binary regression suggests that women with PC <248.010×10 3 /µL were at higher risk of preeclampsia (odds ratio =2.2, 95% confidence interval =1.08-4.6, P =0.03). The PC/MPV cutoff was 31.2 for diagnosis of preeclampsia ( P =0.035, the area under the ROC curve was 62.2%). PC <248.010×10 3 /µL and PC to MPV ratio 31.2 are valid predictors of preeclampsia.
Milošević, Danko; Trkulja, Vladimir; Turudić, Daniel; Batinić, Danica; Spajić, Borislav; Tešović, Goran
2013-12-01
To evaluate urinary bladder wall thickness (BWT) assessed by ultrasound as a diagnostic tool for cystitis cystica. This was a 9-year prospective study comprising 120 prepubertal girls. Sixty subjects of whom half underwent cystoscopy represented cases while the other 60 (those with a single urinary tract infection and healthy subjects) represented controls. Based on receiver operating characteristics (ROC) analysis, BWT discriminated very well between cases and controls with area under the ROC curve close to 1.0. At the optimum cut-off defined at 3.9 mm, negative predictive value (NPV) was 100% leaving no probability of cystic cystitis with BWT <3.9 mm. Positive predictive value (PPV) was also very high (95.2%), indicating only around 4.82% probability of no cystic cystitis in patients with BWT values ≥3.9 mm. BWT could also distinguish between healthy subjects and those with a cured single urinary tract infection, although discriminatory properties were moderate (area under ROC 86.7%, PPV 78.8%, NPV 85.2%). Ultrasound mucosal bladder wall measurement is a non-invasive, simple and quite reliable method in diagnosis of cystitis cystica in prepubertal girls with recurrent urinary tract infections. Copyright © 2013 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Ratzinger, Franz; Schuardt, Michael; Eichbichler, Katherina; Tsirkinidou, Irene; Bauer, Marlene; Haslacher, Helmuth; Mitteregger, Dieter; Binder, Michael; Burgmann, Heinz
2013-01-01
Physicians are regularly faced with severely ill patients at risk of developing infections. In literature, standard care wards are often neglected, although their patients frequently suffer from a systemic inflammatory response syndrome (SIRS) of unknown origin. Fast identification of patients with infections is vital, as they immediately require appropriate therapy. Further, tools with a high negative predictive value (NPV) to exclude infection or bacteremia are important to increase the cost effectiveness of microbiological examinations and to avoid inappropriate antibiotic treatment. In this prospective cohort study, 2,384 patients with suspected infections were screened for suffering from two or more SIRS criteria on standard care wards. The infection probability score (IPS) and sepsis biomarkers with discriminatory power were assessed regarding their capacity to identify infection or bacteremia. In this cohort finally consisting of 298 SIRS-patients, the infection prevalence was 72%. Bacteremia was found in 25% of cases. For the prediction of infection, the IPS yielded 0.51 ROC-AUC (30.1% sensitivity, 64.6% specificity). Among sepsis biomarkers, lipopolysaccharide binding protein (LBP) was the best parameter with 0.63 ROC-AUC (57.5% sensitivity, 67.1% specificity). For the prediction of bacteremia, the IPS performed slightly better with a ROC-AUC of 0.58 (21.3% sensitivity, 65% specificity). Procalcitonin was the best discriminator with 0.78 ROC-AUC, 86.3% sensitivity, 59.6% specificity and 92.9% NPV. Furthermore, bilirubin and LBP (ROC-AUC: 0.65, 0.62) might also be considered as useful parameters. In summary, the IPS and widely used infection parameters, including CRP or WBC, yielded a poor diagnostic performance for the detection of infection or bacteremia. Additional sepsis biomarkers do not aid in discriminating inflammation from infection. For the prediction of bacteremia procalcitonin, and bilirubin were the most promising parameters, which might be used as a rule for when to take blood cultures or using nucleic acid amplification tests for microbiological diagnostics.
Tang, Kun; Liu, Haoran; Jiang, Kehua; Ye, Tao; Yan, Libin; Liu, Peijun; Xia, Ding; Chen, Zhiqiang; Xu, Hua; Ye, Zhangqun
2017-10-17
Neutrophil to lymphocyte ratio (NLR), derived neutrophil to lymphocyte ratio (dNLR), platelet to lymphocyte ratio (PLR) and lymphocyte to monocyte ratio (LMR) were promising biomarkers used to predict diagnosis and prognosis in various inflammatory responses diseases and cancers. However, there have been no reports regarding these biomarkers in kidney stone patients. This study aimed to evaluate the predictive value of inflammatory biomarkers for metabolic syndrome (MetS) and post-PCNL SIRS in nephrolithiasis patients. We retrospectively enrolled 513 patients with nephrolithiasis and 204 healthy controls. NLR, dNLR, LMR and PLR in nephrolithiasis patients were significantly higher than control group. Patients with renal stone have higher NLR, dNLR, LMR and PLR than those without. ROC curve analysis indicated NLR, dNLR, LMR and PLR for predicting patients with nephrolithiasis and MetS, displayed AUC of 0.730, 0.717, 0.627 and 0.606. Additionally, ROC curves, using post-PCNL SIRS as the end-point for NLR, dNLR, LMR and PLR with AUC of 0.831, 0.813, 0.723 and 0.685. Multivariate analysis revealed that NLR, dNLR represented independent factors for predicting post-PCNL SIRS. While LMR independently associated with MetS. These resluts demonstrate preoperative NLR, dNLR and LMR appears to be effective predictors of post-PCNL SIRS and LMR of MetS in nephrolithiasis patients.
A new approach of objective quality evaluation on JPEG2000 lossy-compressed lung cancer CT images
NASA Astrophysics Data System (ADS)
Cai, Weihua; Tan, Yongqiang; Zhang, Jianguo
2007-03-01
Image compression has been used to increase the communication efficiency and storage capacity. JPEG 2000 compression, based on the wavelet transformation, has its advantages comparing to other compression methods, such as ROI coding, error resilience, adaptive binary arithmetic coding and embedded bit-stream. However it is still difficult to find an objective method to evaluate the image quality of lossy-compressed medical images so far. In this paper, we present an approach to evaluate the image quality by using a computer aided diagnosis (CAD) system. We selected 77 cases of CT images, bearing benign and malignant lung nodules with confirmed pathology, from our clinical Picture Archiving and Communication System (PACS). We have developed a prototype of CAD system to classify these images into benign ones and malignant ones, the performance of which was evaluated by the receiver operator characteristics (ROC) curves. We first used JPEG 2000 to compress these cases of images with different compression ratio from lossless to lossy, and used the CAD system to classify the cases with different compressed ratio, then compared the ROC curves from the CAD classification results. Support vector machine (SVM) and neural networks (NN) were used to classify the malignancy of input nodules. In each approach, we found that the area under ROC (AUC) decreases with the increment of compression ratio with small fluctuations.
A semiparametric separation curve approach for comparing correlated ROC data from multiple markers
Tang, Liansheng Larry; Zhou, Xiao-Hua
2012-01-01
In this article we propose a separation curve method to identify the range of false positive rates for which two ROC curves differ or one ROC curve is superior to the other. Our method is based on a general multivariate ROC curve model, including interaction terms between discrete covariates and false positive rates. It is applicable with most existing ROC curve models. Furthermore, we introduce a semiparametric least squares ROC estimator and apply the estimator to the separation curve method. We derive a sandwich estimator for the covariance matrix of the semiparametric estimator. We illustrate the application of our separation curve method through two real life examples. PMID:23074360
Wang, Jiade; Zhang, Tian; Mei, Yu; Pan, Bingjun
2018-06-01
Reverse osmosis concentrate (ROC) of printing and dyeing wastewater remains as a daunting environmental issue, which is characterized by high salinity, chemical oxygen demand (COD), chroma and low biodegradability. In this study electro-oxidation process (PbO 2 /Ti electrode) coupled with oxidation-reduction potential (ORP) online monitor was applied to treat such a ROC effluent. The results show that with the increase of specific electrical charge (Q sp ), the removal efficiencies of COD, TN and chroma increased significantly at the incipience and then reached a gentle stage; the optimal total current efficiency (12.04 kWh m -3 ) was obtained with the current density of 10 mA cm -2 (Q sp , 3.0 Ah L -1 ). Meanwhile, some inorganic ions can be simultaneously removed to varying degrees. FTIR analyses indicated that the macromolecular organics were decomposed into smaller molecules. A multi-parameter linear relationship between ORP and Q sp , COD and Cl - concentration was established, which can quantitatively reflect the effect of current density, chloride ion concentration, pollutants and reaction time on the performance of the electro-oxidation system. As compared to a traditional constant-current system, the constant-ORP system developed in this study (through the back-propagation neural network [BPN] model with ORP monitoring) approximately reduced the energy cost by 24-29%. The present work is expected to provide a potential alternative in optimizing the electro-oxidation process. Copyright © 2018 Elsevier Ltd. All rights reserved.
Blood-based biomarkers used to predict disease activity in Crohn's disease and ulcerative colitis.
Burakoff, Robert; Pabby, Vikas; Onyewadume, Louisa; Odze, Robert; Adackapara, Cheryl; Wang, Wei; Friedman, Sonia; Hamilton, Matthew; Korzenik, Joshua; Levine, Jonathan; Makrauer, Frederick; Cheng, Changming; Smith, Hai Choo; Liew, Choong-Chin; Chao, Samuel
2015-05-01
Identifying specific genes that are differentially expressed during inflammatory bowel disease flares may help stratify disease activity. The aim of this study was to identify panels of genes to be able to distinguish disease activity in Crohn's disease (CD) and ulcerative colitis (UC). Patients were grouped into categories based on disease and severity determined by histological grading. Whole blood was collected by PAXgene Blood RNA collection tubes, (PreAnalytiX) and gene expression analysis using messenger RNA was conducted. Logistic regression was performed on multiple combinations of common probe sets, and data were evaluated in terms of discrimination by computing the area under the receiving operator characteristic curve (ROC-AUC). Nine inactive CD, 8 mild CD, 10 moderate-to-severe CD, 9 inactive UC, 8 mild UC, 10 moderate-to-severe UC, and 120 controls were hybridized to Affymetrix U133 Plus 2 microarrays. Panels of 6 individual genes discriminated the stages of disease activity: CD with mild severity {ROC-AUC, 0.89 (95% confidence interval [CI], 0.84%-0.95%)}, CD with moderate-to-severe severity (ROC-AUC 0.98 [95% CI, 0.97-1.0]), UC with mild severity (ROC-AUC 0.92 [95% CI, 0.87-0.96]), and UC with moderate-to-severe severity (ROC-AUC 0.99 [95% CI, 0.97-1.0]). Validation by real-time reverse transcription-PCR confirmed the Affymetrix microarray data. The specific whole blood gene panels reliably distinguished CD and UC and determined the activity of disease, with high sensitivity and specificity in our cohorts of patients. This simple serological test has the potential to become a biomarker to determine the activity of disease.
ERIC Educational Resources Information Center
Broder, Arndt; Schutz, Julia
2009-01-01
Recent reviews of recognition receiver operating characteristics (ROCs) claim that their curvilinear shape rules out threshold models of recognition. However, the shape of ROCs based on confidence ratings is not diagnostic to refute threshold models, whereas ROCs based on experimental bias manipulations are. Also, fitting predicted frequencies to…
Variations in Recollection: The Effects of Complexity on Source Recognition
ERIC Educational Resources Information Center
Parks, Colleen M.; Murray, Linda J.; Elfman, Kane; Yonelinas, Andrew P.
2011-01-01
Whether recollection is a threshold or signal detection process is highly controversial, and the controversy has centered in part on the shape of receiver operating characteristics (ROCs) and z-transformed ROCs (zROCs). U-shaped zROCs observed in tests thought to rely heavily on recollection, such as source memory tests, have provided evidence in…
Bonina, Francesco P; Puglia, Carmelo; Frasca, Giuseppina; Cimino, Francesco; Trombetta, Domenico; Tringali, Giovanni; Roccazzello, Annamaria; Insiriello, Elio; Rapisarda, Paolo; Saija, Antonella
2008-01-01
Several pathological conditions have all been associated with a higher release of atmospheric pollutants. There is growing evidence that oxidative stress may represent one of the agents involved in the initiation and/or progression of many of these pathologies. The aim of the present study was to evaluate the effects of short-term dietary supplementation with a standardised red orange extract (ROC) on a group of traffic police officers exposed to traffic exhaust pollution and cigarette smoking, by measuring some noninvasive biomarkers of oxidative stress. At the beginning of the study, all the groups showed similar serum lipid hydroperoxide levels, but traffic officers showed lower serum concentrations of thiol (SH) groups; furthermore, the frequency of spontaneous sister chromatide exchanges (SCEs) in peripheral lymphocytes was increased by smoking (but not by pollution exposure alone) at a higher degree in subjects exposed to traffic pollution. After 1 month of ROC administration, serum lipid hydroperoxide levels decreased only in all non-smoking subjects; furthermore, SH group levels measured in traffic officers appeared restored to normal values observed in the respective controls. Finally, the increase in SCE frequency induced by smoking was reduced by treatment with ROC especially in traffic officers. Our study suggests that ROC supplementation could be useful to minimise the detrimental effects caused by exposure to air pollution and smoking.
NASA Astrophysics Data System (ADS)
Chawla, Amarpreet S.; Samei, Ehsan; Abbey, Craig
2007-03-01
In this study, we used a mathematical observer model to combine information obtained from multiple angular projections of the same breast to determine the overall detection performance of a multi-projection breast imaging system in detectability of a simulated mass. 82 subjects participated in the study and 25 angular projections of each breast were acquired. Projections from a simulated 3 mm 3-D lesion were added to the projection images. The lesion was assumed to be embedded in the compressed breast at a distance of 3 cm from the detector. Hotelling observer with Laguerre-Gauss channels (LG CHO) was applied to each image. Detectability was analyzed in terms of ROC curves and the area under ROC curves (AUC). The critical question studied is how to best integrate the individual decision variables across multiple (correlated) views. Towards that end, three different methods were investigated. Specifically, 1) ROCs from different projections were simply averaged; 2) the test statistics from different projections were averaged; and 3) a Bayesian decision fusion rule was used. Finally, AUC of the combined ROC was used as a parameter to optimize the acquisition parameters to maximize the performance of the system. It was found that the Bayesian decision fusion technique performs better than the other two techniques and likely offers the best approximation of the diagnostic process. Furthermore, if the total dose level is held constant at 1/25th of dual-view mammographic screening dose, the highest detectability performance is observed when considering only two projections spread along an angular span of 11.4°.
Pradhan, Shovana; Fan, Linhua; Roddick, Felicity A
2015-10-01
Reverse osmosis (RO) concentrate (ROC) streams generated from RO-based municipal wastewater reclamation processes pose potential health and environmental risks on their disposal to confined water bodies such as bays. A UV/H2O2 advanced oxidation process followed by a biological activated carbon (BAC) treatment was evaluated at lab-scale for the removal of organic and nutrient content from a highly saline ROC (TDS 16 g L(-1), EC 23.5 mS cm(-1)) for its safe disposal to the receiving environment. Over the 230-day operation of the UV/H2O2-BAC process, the colour and UV absorbance (254 nm) of the ROC were reduced to well below those of the influent to the reclamation process. The concentrations of DOC and total nitrogen (TN) were reduced by approximately 60% at an empty bed contact time (EBCT) of 60 min. The reduction in ammonia nitrogen by the BAC remained high under all conditions tested (>90%). Further investigation confirmed that the presence of residual peroxide in the UV/H2O2 treated ROC was beneficial for DOC removal, but markedly inhibited the activities of the nitrifying bacteria (i.e., nitrite oxidising bacteria) in the BAC system and hence compromised total nitrogen removal. This work demonstrated that the BAC treatment could be acclimated to the very high salinity environment, and could be used as a robust method for the removal of organic matter and nitrogen from the pre-oxidised ROC under optimised conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Swensson, Richard G.; King, Jill L.; Good, Walter F.; Gur, David
2000-04-01
A constrained ROC formulation from probability summation is proposed for measuring observer performance in detecting abnormal findings on medical images. This assumes the observer's detection or rating decision on each image is determined by a latent variable that characterizes the specific finding (type and location) considered most likely to be a target abnormality. For positive cases, this 'maximum- suspicion' variable is assumed to be either the value for the actual target or for the most suspicious non-target finding, whichever is the greater (more suspicious). Unlike the usual ROC formulation, this constrained formulation guarantees a 'well-behaved' ROC curve that always equals or exceeds chance- level decisions and cannot exhibit an upward 'hook.' Its estimated parameters specify the accuracy for separating positive from negative cases, and they also predict accuracy in locating or identifying the actual abnormal findings. The present maximum-likelihood procedure (runs on PC with Windows 95 or NT) fits this constrained formulation to rating-ROC data using normal distributions with two free parameters. Fits of the conventional and constrained ROC formulations are compared for continuous and discrete-scale ratings of chest films in a variety of detection problems, both for localized lesions (nodules, rib fractures) and for diffuse abnormalities (interstitial disease, infiltrates or pnumothorax). The two fitted ROC curves are nearly identical unless the conventional ROC has an ill behaved 'hook,' below the constrained ROC.
Predictive Value of Morphological Features in Patients with Autism versus Normal Controls
ERIC Educational Resources Information Center
Ozgen, H.; Hellemann, G. S.; de Jonge, M. V.; Beemer, F. A.; van Engeland, H.
2013-01-01
We investigated the predictive power of morphological features in 224 autistic patients and 224 matched-pairs controls. To assess the relationship between the morphological features and autism, we used the receiver operator curves (ROC). In addition, we used recursive partitioning (RP) to determine a specific pattern of abnormalities that is…
The global nonmethane reactive organic carbon budget: A modeling perspective
NASA Astrophysics Data System (ADS)
Safieddine, Sarah A.; Heald, Colette L.; Henderson, Barron H.
2017-04-01
The cycling of reactive organic carbon (ROC) is central to tropospheric chemistry. We characterize the global tropospheric ROC budget as simulated with the GEOS-Chem model. We expand the standard simulation by including new emissions and gas-phase chemistry, an expansion of dry and wet removal, and a mass tracking of all ROC species to achieve carbon closure. The resulting global annual mean ROC burden is 16 Tg C, with sources from methane oxidation and direct emissions contributing 415 and 935 Tg C yr-1. ROC is lost from the atmosphere via physical deposition (460 Tg C yr-1), and oxidation to CO/CO2 (875 Tg C yr-1). Ketones, alkanes, alkenes, and aromatic hydrocarbons dominate the ROC burden, whereas aldehydes and isoprene dominate the ROC global mean surface OH reactivity. Simulated OH reactivities are between 0.8-1 s-1, 3-14 s-1, and 12-34 s-1 over selected regions in the remote ocean, continental midlatitudes, and the tropics, respectively, and are consistent with observational constraints.
Chen, Jiaxi; Li, Shuang; Shi, Jianfeng; Zhang, Lili; Li, Jun; Chen, Shiyong; Wu, Chunlong; Shen, Bo
2016-03-01
Soluble progranulin (PGRN) is known to directly regulate regulatory T cells; however, whether PGRN levels are elevated in patients with rheumatoid arthritis and affect the regulatory subsets of B cells remain unknown. In this study, a total of 80 RA patients and 60 healthy controls were studied. Serum progranulin levels were determined using enzyme-linked immune-sorbent assay. A receiver operating characteristic (ROC) curve was used to evaluate the feasibility of serum PGRN as a biomarker for distinguishing patients with RA. CD19(+)CD5(+)GrB(+) B cells were analyzed by flow cytometry in peripheral blood mononuclear cells (PBMCs). Serum progranulin levels in RA patients (median, 59.4 ng/mL) and in RA patients DAS28 > 5.1 (median, 71.98 ng/mL) were much higher than those in normal controls (median, 46.3 ng/mL; P < 0.001). The area under the ROC curve for progranulin levels was 0.705 for RA versus normal controls and the area under the ROC curve for progranulin levels in RA patients DAS28 > 5.1 was 0.977 versus normal controls (P < 0.001). Interestingly, serum progranulin and DAS28, CRP, ESR were all positively correlated in RA patients (P < 0.001). The number of CD19(+)CD5(+)GrB(+) B cells was significantly higher in RA patients (P < 0.05); however, the level of Breg cells was not related to PGRN (P > 0.05). Our findings indicated that induction of PGRN expression may play a role in RA immune reaction and PGRN levels could be a useful biomarker in RA inflammatory response, but irrelated with Breg cell levels.
NASA Astrophysics Data System (ADS)
Obuchowski, Nancy A.; Bullen, Jennifer A.
2018-04-01
Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.
Tolerance and resistance characteristics of microalgae Scenedesmus sp. LX1 to methylisothiazolinone.
Wang, Xiao-Xiong; Zhang, Tian-Yuan; Dao, Guo-Hua; Hu, Hong-Ying
2018-05-25
Methylisothiazolinone (MIT) has been widely used to control bacterial growth in reverse osmosis (RO) systems. However, MIT's toxicity on microalgae should be determined because residual MIT is concentrated into RO concentrate (ROC) and might have a severe impact on microalgae-based ROC treatment. This study investigated the tolerance of Scenedesmus sp. LX1 to MIT and revealed the mechanism of algal growth inhibition and toxicity resistance. Scenedesmus sp. LX1 was inhibited by MIT with a half-maximal effective concentration at 72 h (72 h-EC 50 ) of 1.00 mg/L, but the strain recovered from the inhibition when its growth was not completely inhibited. It was observed that this inhibition's effect on subsequent growth was weak, and the removal of MIT was the primary reason for the recovery. Properly increasing the initial algal density significantly shortened the adaptation time for accelerated recovery in a MIT-containing culture. Photosynthesis damage by MIT was one of the primary reasons for growth inhibition, but microalgal cell respiration and adenosine triphosphate (ATP) synthesis were not completely inhibited, and the algae were still alive even when growth was completely inhibited, which was notably different from observations made with bacteria and fungi. The algae synthesized more chlorophyll, antioxidant enzymes of superoxide dismutase (SOD) and catalase (CAT), and small molecules, such as reduced glutathione (GSH), to resist MIT poisoning. The microalgae-based process could treat the MIT-containing ROC, since MIT was added for only several hours a week in municipal wastewater reclamation RO processes, and the MIT average concentration was considerably lower than the maximum concentration that algae could tolerate. Copyright © 2018. Published by Elsevier Ltd.
Artificial neural network study on organ-targeting peptides
NASA Astrophysics Data System (ADS)
Jung, Eunkyoung; Kim, Junhyoung; Choi, Seung-Hoon; Kim, Minkyoung; Rhee, Hokyoung; Shin, Jae-Min; Choi, Kihang; Kang, Sang-Kee; Lee, Nam Kyung; Choi, Yun-Jaie; Jung, Dong Hyun
2010-01-01
We report a new approach to studying organ targeting of peptides on the basis of peptide sequence information. The positive control data sets consist of organ-targeting peptide sequences identified by the peroral phage-display technique for four organs, and the negative control data are prepared from random sequences. The capacity of our models to make appropriate predictions is validated by statistical indicators including sensitivity, specificity, enrichment curve, and the area under the receiver operating characteristic (ROC) curve (the ROC score). VHSE descriptor produces statistically significant training models and the models with simple neural network architectures show slightly greater predictive power than those with complex ones. The training and test set statistics indicate that our models could discriminate between organ-targeting and random sequences. We anticipate that our models will be applicable to the selection of organ-targeting peptides for generating peptide drugs or peptidomimetics.
Krawchuk, Meg A.; Haire, Sandra L.; Coop, Jonathan D.; Parisien, Marc-Andre; Whitman, Ellen; Chong, Geneva W.; Miller, Carol
2016-01-01
for seven study fires that burned in conifer-dominated forested landscapes of the Western Cordillera of Canada between 2001 and 2014. We fit nine models, each for distinct levels of fire weather and terrain ruggedness. Our framework revealed that the predictability and abundance of fire refugia varied among these environmental settings. We observed highest predictability under moderate fire weather conditions and moderate terrain ruggedness (ROC-AUC = 0.77), and lowest predictability in flatter landscapes and under high fire weather conditions (ROC-AUC = 0.63–0.68). Catchment slope, local aspect, relative position, topographic wetness, topographic convergence, and local slope all contributed to discriminating where refugia occur but the relative importance of these topographic controls differed among environments. Our framework allows us to characterize the predictability of contemporary fire refugia across multiple environmental settings and provides important insights for ecosystem resilience, wildfire management, conservation planning, and climate change adaptation.
Hantouche, E G; Demonfaucon, C
2008-12-01
Despite significant advances in clinical research, Obsessive Compulsive Disorder, OCD represents a difficult to treat condition. The French Association of patients suffering from OCD, "AFTOC" is highly concerned by this issue. A new survey was implemented with the aim of exploring Resistant Obsessive Compulsive disorder "ROC". Patients with OCD and members of the "AFTOC" were included in the survey. A self-rated file was elaborated in order to get the maximum of information on the clinical and therapeutic aspects and conditions of OCD. The full version of "TEMPS-A" was also included for assessment of affective temperaments. Statistical analyses were performed for inter-group comparison between "ROC" (resistant OCD) and good responders. Logistic regression analyses with "ROC" method were used to search for independent predictive factors to "ROC". The new survey of "AFTOC", "TOC & ROC" selected a sample of 360 patients, who are members of the association. The rate of "ROC" was 44.2%, 25.3% of Good Responders (GR), and 30.5% in between. Inter-group comparisons ("ROC" versus GR) showed significant higher rates of psychiatric admissions (49% versus 28%), and suicide attempts (26% versus 13%), greater numbers of doctors consulted (5.5 versus. 3.2), compulsions (4.6 versus 3.4), and psychiatric comorbidity (2.8 disorders versus. 2.0; notably agoraphobia, social anxiety and worry about appearance) in the "ROC" group. Assessment by full "TEMPS-A" scale revealed, significantly higher rates of Cyclothymic Temperament (63% versus 43%; p: 0.0003), Depressive Temperament (72% versus 53%; p: 0.004), and Irritable Temperament (21% versus 9%; p: 0.02) in the ROC group. Moreover, the mean global score on each of these temperaments was significantly higher in the "ROC" group. No difference was obtained in the rate or the mean score on the hyperthymic temperament scale. The most predictive factors of "ROC" were represented by "slow continuous course", "worsening under SRI", "worry about appearance", current age above 40 years and psychiatric admission. Our data provides a more precise clinical picture of "ROC", which should be initially explored through baseline severity, compulsive dominance, hoarding, special comorbidity such as recurrent depression, obsession of appearance, agoraphobia, social anxiety, and complex mixture of unstable affective temperament (cyclothymic, irritable, and depressive), and course of illness. Furthermore, vigilance towards the notion of worsening linked to drug therapy, and the increased suicide risk is warranted in the clinical management of "ROC".
[Law for the protection of returned overseas Chinese 7 September 1990].
1990-09-10
The full text of the Beijing, China law on protection of returned overseas Chinese (ROC) (gui giao 2981 0294) and overseas Chinese families (OCF) (gui giao 0294 4187) is reported as effective on January 1, 1991 and adopted by the 7th National People's Congress Standing Committee on September 7, 1990. There are 22 articles. The 1st 2 articles define the population referred to: ROC are those Chinese who have returned and settled in China. OCF are those who have settled abroad. Family includes parents, children, spouses, brothers, sisters, grandparents, and grandchildren, and other relative receiving longterm support form overseas Chinese (OC). ROC and OCF have the same citizen rights and obligations prescribed in the constitution and other laws. ROC shall be resettled by the state. Concentrations of ROC in an area assures representation in the National People's Congress and people's congresses. ROC and OC have the right to organize social groups; the property of social groups is protected by law. In article 7, the state assures support for ranches and tree farms and school and medical care. Article 8 provides for local government support for investments of ROC, OC and OCF in industry and land commerce. Article 9 indicates government support at all levels for public services; tariffs will be reduced or exempted on donated materials and equipment brought from abroad. Private ownership of houses of ROC and OC is secured in article 10, and compensation is provided if the state appropriates the housing. ROC students and children of ROC and OC children in China are assured of support for education and employment assistance in article 11. Remittances of ROC and OCF received from abroad are protected in article 12. Article 13 secures the right of ROC and OCF to inheritance and gifts from relatives living abroad. ROC and OCF may dispose of overseas property. Article 15 requires examination of departure applications by relevant authorities. Emergency situations are accounted for. Article 16 protects the rights of visitation of a family still overseas. Article 17 assures the rights of ROC and OCF to settle abroad, and shall upon retirement continue to receive pensions, for instance. Article 18 assures assistance for study abroad. Article 19 assures rights of OC and OCF under international treaties. Article 10 provides the right to address grievances when laws have been violated. The State Council has the responsibility to prepare implementation measures pertinent to this law.
Knowledge-Based Systems Approach to Wilderness Fire Management.
NASA Astrophysics Data System (ADS)
Saveland, James M.
The 1988 and 1989 forest fire seasons in the Intermountain West highlight the shortcomings of current fire policy. To fully implement an optimization policy that minimizes the costs and net value change of resources affected by fire, long-range fire severity information is essential, yet lacking. This information is necessary for total mobility of suppression forces, implementing contain and confine suppression strategies, effectively dealing with multiple fire situations, scheduling summer prescribed burning, and wilderness fire management. A knowledge-based system, Delphi, was developed to help provide long-range information. Delphi provides: (1) a narrative of advice on where a fire might spread, if allowed to burn, (2) a summary of recent weather and fire danger information, and (3) a Bayesian analysis of long-range fire danger potential. Uncertainty is inherent in long-range information. Decision theory and judgment research can be used to help understand the heuristics experts use to make decisions under uncertainty, heuristics responsible both for expert performance and bias. Judgment heuristics and resulting bias are examined from a fire management perspective. Signal detection theory and receiver operating curve (ROC) analysis can be used to develop a long-range forecast to improve decisions. ROC analysis mimics some of the heuristics and compensates for some of the bias. Most importantly, ROC analysis displays a continuum of bias from which an optimum operating point can be selected. ROC analysis is especially appropriate for long-range forecasting since (1) the occurrence of possible future events is stated in terms of probability, (2) skill prediction is displayed, (3) inherent trade-offs are displayed, and (4) fire danger is explicitly defined. Statements on the probability of the energy release component of the National Fire Danger Rating System exceeding a critical value later in the fire season can be made early July in the Intermountain West. Delphi was evaluated formally and informally. Continual evaluation and feedback to update knowledge-based systems results in a repository for current knowledge, and a means to devise policy that will augment existing knowledge. Thus, knowledge-based systems can help implement adaptive resource management.
Wang, Xin; Li, Zong-Xiao; Wen, Yu-Peng; Chang, Cheng
2018-01-01
To study the value of indoleamine 2,3-dioxygenase (IDO) in the early diagnosis of systemic inflammatory response syndrome (SIRS) after cardiopulmonary bypass in children with congenital heart disease. A total of 90 children with congenital heart disease who underwent cardiopumonary bypass surgery between May 2012 and January 2016 were enrolled. According to the prsence or absence of SIRS after surgery, they were divided into SIRS group (n=43) and control group (n=47). Peripheral blood samples were collected before surgery, during surgery, and after surgery. Serum levels of IDO, C-reactive protein (CRP), and interleukin-6 (IL-6) were measured and compared between the two groups. The receiver operating characteristic (ROC) curve was used to evaluate their diagnostic efficiency. Compared with the control group, the SIRS group had higher serum CRP levels at 72 hours after surgery, higher IL-6 levels during surgery and at 72 hours after surgery, and higher IDO levels at 24 and 72 hours after surgery. IDO had a certain value in the diagnosis of SIRS at 24 hours after surgery with an area under the ROC curve (AUC) of 0.793, a specificity of 100%, and a sensitivity of 58.14%. CRP, IL-6, and IDO had a certain value in the diagnosis of SIRS at 72 hours after surgery. IDO had the highest diagnostic efficiency with an AUC of 0.927, a specificity of 95.74%, and a sensitivity of 76.74% at 72 hours after surgery. IL-6, CRP, and IDO have a certain value in the diagnosis of SIRS after surgery for congenital heart disease, and IDO has a higher diagnostic efficiency. IDO can predict the development of SIRS in children after surgery for congenital heart disease earlier.
14-3-3η Autoantibodies: Diagnostic Use in Early Rheumatoid Arthritis.
Maksymowych, Walter P; Boire, Gilles; van Schaardenburg, Dirkjan; Wichuk, Stephanie; Turk, Samina; Boers, Maarten; Siminovitch, Katherine A; Bykerk, Vivian; Keystone, Ed; Tak, Paul Peter; van Kuijk, Arno W; Landewé, Robert; van der Heijde, Desiree; Murphy, Mairead; Marotta, Anthony
2015-09-01
To describe the expression and diagnostic use of 14-3-3η autoantibodies in early rheumatoid arthritis (RA). 14-3-3η autoantibody levels were measured using an electrochemiluminescent multiplexed assay in 500 subjects (114 disease-modifying antirheumatic drug-naive patients with early RA, 135 with established RA, 55 healthy, 70 autoimmune, and 126 other non-RA arthropathy controls). 14-3-3η protein levels were determined in an earlier analysis. Two-tailed Student t tests and Mann-Whitney U tests compared differences among groups. Receiver-operator characteristic (ROC) curves were generated and diagnostic performance was estimated by area under the curve (AUC), as well as specificity, sensitivity, and likelihood ratios (LR) for optimal cutoffs. Median serum 14-3-3η autoantibody concentrations were significantly higher (p < 0.0001) in patients with early RA (525 U/ml) when compared with healthy controls (235 U/ml), disease controls (274 U/ml), autoimmune disease controls (274 U/ml), patients with osteoarthritis (259 U/ml), and all controls (265 U/ml). ROC curve analysis comparing early RA with healthy controls demonstrated a significant (p < 0.0001) AUC of 0.90 (95% CI 0.85-0.95). At an optimal cutoff of ≥ 380 U/ml, the ROC curve yielded a sensitivity of 73%, a specificity of 91%, and a positive LR of 8.0. Adding 14-3-3η autoantibodies to 14-3-3η protein positivity enhanced the identification of patients with early RA from 59% to 90%; addition of 14-3-3η autoantibodies to anticitrullinated protein antibodies (ACPA) and/or rheumatoid factor (RF) increased identification from 72% to 92%. Seventy-two percent of RF- and ACPA-seronegative patients were positive for 14-3-3η autoantibodies. 14-3-3η autoantibodies, alone and in combination with the 14-3-3η protein, RF, and/or ACPA identified most patients with early RA.
76 FR 36923 - Announcement of Availability of the Report on Carcinogens, Twelfth Edition
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-23
... 12th RoC to the public on June 10, 2011. The report is available on the RoC Web site at: http://ntp... substances listed in the previous edition. Information about the RoC is available on the RoC Web site ( http... evaluate the scientific evidence on each candidate substance under review ( http://ntp.niehs.nih.gov/go...
Li, Jun; Feng, Yi; Han, Jisheng; Fan, Bifa; Wu, Dasheng; Zhang, Daying; Du, Dongping; Li, Hui; Lim, Jian; Wang, Jiashuang; Jin, Yi; Fu, Zhijian
2012-01-01
Neuropathic pain questionnaires are efficient diagnostic tools for neuropathic pain and play an important role in neuropathic pain epidemiologic studies in China. No comparison data was available in regards to the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS), the Neuropathic Pain Questionnaire (NPQ) and ID Pain within and among the same population. To achieve a linguistic adaptation, validation, and comparison of Chinese versions of the 3 neuropathic pain questionnaires (LANSS, NPQ and ID Pain). A nonrandomized, controlled, prospective, multicenter trial. Ten pain centers in China. Two forward translations followed by comparison and reconciliation of the translations. Comparison of the 2 backward translations with the original version was made to establish consistency and accuracy of the translations. Pilot testing and pain specialists' evaluations were also required. A total of 140 patients were enrolled in 10 centers throughout China: 70 neuropathic pain patients and 70 nociceptive pain patients. Reliability (Cronbach's alpha coefficients and Guttman split-half coefficients) and validity (sensitivity, specificity, positive and negative predictive values, receiver operating characteristic [ROC] curves and the area under the ROC curves) of the 3 questionnaires were determined. ROC curves and the area under the ROC curves of the 3 questionnaires were also compared. Chinese versions of LANSS, NPQ and ID Pain had a good reliability (Cronbach's alpha coefficients and Guttman split-half coefficients were greater than 0.7). Sensitivity, specificity, positive and negative predictive values of the Chinese versions of LANSS and ID Pain were considerably high ( > 80%). The area under the ROC curves of LANSS and ID Pain was significantly higher than that of NPQ (P < 0.05). There was no statistically significant difference between the area under the ROC curves of LANSS and ID Pain (P > 0.05). The study was based on patients with a high school degree or above, which limited the application of the 3 neuropathic pain questionnaires to patients with lower educational levels. The Chinese versions of LANSS and ID Pain developed and validated by this study can be used as a diagnostic tool in differentiating neuropathic pain in patients whose native language is Chinese (Mandarin).
Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret
2008-01-01
The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.
The effects of thermal gradients on the Mars Observer Camera primary mirror
NASA Technical Reports Server (NTRS)
Applewhite, Roger W.; Telkamp, Arthur R.
1992-01-01
The paper discusses the effect of thermal gradients on the optical performance of the primary mirror of Mars Observer Camera (MOC), which will be launched on the Mars Observer spacecraft in September 1992. It was found that mild temperature gradients can have a large effect on the mirror surface figure, even for relatively low coefficient-of-thermal-expansion materials. However, in the case of the MOC primary mirror, it was found that the radius of curvature (ROC) of the reflective surface of the mirror changed in a nearly linear fashion with the radial temperature gradient, with little additional aberration. A solid-state ROC controller using the thermal gradient effect was implemented and verified.
Epidemiology, Causes and Prevention of Car Rollover Crashes with Ejection
El-Hennawy, HM; El-Menyar, A; Al-Thani, H; Tuma, M; Parchani, A; Abdulrahman, H; Peralta, R; Asim, M; Zarour, A; Latifi, R
2014-01-01
Rollover crashes (ROCs) are responsible for almost a third of all highway vehicle occupant fatalities. Although ROCs are common and serious mechanism of injury, ROCs are under-reported. To analyze the causes, mechanism, impact and prevention of ROCs, we reviewed the literature between 1984 and 2013. By utilizing the search engines PubMed, MEDLINE and EMBASE by using key words “ROCs” “Ejection” and “vehicle” the initial search yielded 241 abstracts, of which 58 articles were relevant. Most of the articles were either retrospective or experimental studies funded by automobile companies. All vehicles are susceptible to rollovers to certain extents. Despite continuing innovation in vehicles’ safety, human factor is pivotal in prevention of ROCs. Distracted driving, speeding and drinking escalate the chances of rollover crashes. Wearing a seatbelt greatly improves the chances of surviving a ROC. PMID:25221693
Equivalence of binormal likelihood-ratio and bi-chi-squared ROC curve models
Hillis, Stephen L.
2015-01-01
A basic assumption for a meaningful diagnostic decision variable is that there is a monotone relationship between it and its likelihood ratio. This relationship, however, generally does not hold for a decision variable that results in a binormal ROC curve. As a result, receiver operating characteristic (ROC) curve estimation based on the assumption of a binormal ROC-curve model produces improper ROC curves that have “hooks,” are not concave over the entire domain, and cross the chance line. Although in practice this “improperness” is usually not noticeable, sometimes it is evident and problematic. To avoid this problem, Metz and Pan proposed basing ROC-curve estimation on the assumption of a binormal likelihood-ratio (binormal-LR) model, which states that the decision variable is an increasing transformation of the likelihood-ratio function of a random variable having normal conditional diseased and nondiseased distributions. However, their development is not easy to follow. I show that the binormal-LR model is equivalent to a bi-chi-squared model in the sense that the families of corresponding ROC curves are the same. The bi-chi-squared formulation provides an easier-to-follow development of the binormal-LR ROC curve and its properties in terms of well-known distributions. PMID:26608405
Slotnick, Scott D; Jeye, Brittany M; Dodson, Chad S
2016-01-01
Is recollection a continuous/graded process or a threshold/all-or-none process? Receiver operating characteristic (ROC) analysis can answer this question as the continuous model and the threshold model predict curved and linear recollection ROCs, respectively. As memory for plurality, an item's previous singular or plural form, is assumed to rely on recollection, the nature of recollection can be investigated by evaluating plurality memory ROCs. The present study consisted of four experiments. During encoding, words (singular or plural) or objects (single/singular or duplicate/plural) were presented. During retrieval, old items with the same plurality or different plurality were presented. For each item, participants made a confidence rating ranging from "very sure old", which was correct for same plurality items, to "very sure new", which was correct for different plurality items. Each plurality memory ROC was the proportion of same versus different plurality items classified as "old" (i.e., hits versus false alarms). Chi-squared analysis revealed that all of the plurality memory ROCs were adequately fit by the continuous unequal variance model, whereas none of the ROCs were adequately fit by the two-high threshold model. These plurality memory ROC results indicate recollection is a continuous process, which complements previous source memory and associative memory ROC findings.
ROBOCAL: Gamma-ray isotopic hardware/software interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurd, J.R.; Bonner, C.A.; Ostenak, C.A.
1989-01-01
ROBOCAL, presently being developed at the Los Alamos National Laboratory, is a full-scale prototypical robotic system for remotely performing calorimetric and gamma-ray isotopics measurements of nuclear materials. It features a fully automated vertical stacker-retriever for storing and retrieving packaged nuclear materials from a multi-drawer system, and a fully automated, uniquely integrated gantry robot for programmable selection and transfer of nuclear materials to calorimetric and gamma-ray isotopic measurement stations. Since ROBOCAL is to require almost no operator intervention, a mechanical control system is required in addition to a totally automated assay system. The assay system must be a completely integrated datamore » acquisition and isotopic analysis package fully capable of performing state-of-the-art homogeneous and heterogeneous analyses on many varied matrices. The TRIFID assay system being discussed at this conference by J. G. Fleissner of the Rocky Flats Plant has been adopted because of its many automated features. These include: MCA/ADC setup and acquisition; spectral storage and analysis utilizing an expert system formalism; report generation with internal measurement control printout; user friendly screens and menus. The mechanical control portion consists primarily of two detector platforms and a sample platform, each with independent movement. Some minor modifications and additions are needed with TRIFID to interface the assay and mechanical portions with the CimRoc 4000 software controlling the robot. 6 refs., 5 figs., 3 tabs.« less
Data Acquisition Backbone Core DABC release v1.0
NASA Astrophysics Data System (ADS)
Adamczewski-Musch, J.; Essel, H. G.; Kurz, N.; Linev, S.
2010-04-01
The Data Acquisition Backbone Core (DABC) is a general purpose software framework designed for the implementation of a wide-range of data acquisition systems - from various small detector test beds to high performance systems. DABC consists of a compact data-flow kernel and a number of plug-ins for various functional components like data inputs, device drivers, user functional modules and applications. DABC provides configurable components for implementing event building over fast networks like InfiniBand or Gigabit Ethernet. A generic Java GUI provides the dynamic control and visualization of control parameters and commands, provided by DIM servers. A first set of application plug-ins has been implemented to use DABC as event builder for the front-end components of the GSI standard DAQ system MBS (Multi Branch System). Another application covers the connection to DAQ readout chains from detector front-end boards (N-XYTER) linked to read-out controller boards (ROC) over UDP into DABC for event building, archiving and data serving. This was applied for data taking in the September 2008 test beamtime for the CBM experiment at GSI. DABC version 1.0 is released and available from the website.
Rocker: Open source, easy-to-use tool for AUC and enrichment calculations and ROC visualization.
Lätti, Sakari; Niinivehmas, Sanna; Pentikäinen, Olli T
2016-01-01
Receiver operating characteristics (ROC) curve with the calculation of area under curve (AUC) is a useful tool to evaluate the performance of biomedical and chemoinformatics data. For example, in virtual drug screening ROC curves are very often used to visualize the efficiency of the used application to separate active ligands from inactive molecules. Unfortunately, most of the available tools for ROC analysis are implemented into commercially available software packages, or are plugins in statistical software, which are not always the easiest to use. Here, we present Rocker, a simple ROC curve visualization tool that can be used for the generation of publication quality images. Rocker also includes an automatic calculation of the AUC for the ROC curve and Boltzmann-enhanced discrimination of ROC (BEDROC). Furthermore, in virtual screening campaigns it is often important to understand the early enrichment of active ligand identification, for this Rocker offers automated calculation routine. To enable further development of Rocker, it is freely available (MIT-GPL license) for use and modifications from our web-site (http://www.jyu.fi/rocker).
NASA Astrophysics Data System (ADS)
Lederman, Dror; Zheng, Bin; Wang, Xingwei; Wang, Xiao Hui; Gur, David
2011-03-01
We have developed a multi-probe resonance-frequency electrical impedance spectroscope (REIS) system to detect breast abnormalities. Based on assessing asymmetry in REIS signals acquired between left and right breasts, we developed several machine learning classifiers to classify younger women (i.e., under 50YO) into two groups of having high and low risk for developing breast cancer. In this study, we investigated a new method to optimize performance based on the area under a selected partial receiver operating characteristic (ROC) curve when optimizing an artificial neural network (ANN), and tested whether it could improve classification performance. From an ongoing prospective study, we selected a dataset of 174 cases for whom we have both REIS signals and diagnostic status verification. The dataset includes 66 "positive" cases recommended for biopsy due to detection of highly suspicious breast lesions and 108 "negative" cases determined by imaging based examinations. A set of REIS-based feature differences, extracted from the two breasts using a mirror-matched approach, was computed and constituted an initial feature pool. Using a leave-one-case-out cross-validation method, we applied a genetic algorithm (GA) to train the ANN with an optimal subset of features. Two optimization criteria were separately used in GA optimization, namely the area under the entire ROC curve (AUC) and the partial area under the ROC curve, up to a predetermined threshold (i.e., 90% specificity). The results showed that although the ANN optimized using the entire AUC yielded higher overall performance (AUC = 0.83 versus 0.76), the ANN optimized using the partial ROC area criterion achieved substantially higher operational performance (i.e., increasing sensitivity level from 28% to 48% at 95% specificity and/ or from 48% to 58% at 90% specificity).
Beck, Ben; Bray, Janet E; Smith, Karen; Walker, Tony; Grantham, Hugh; Hein, Cindy; Thorrowgood, Melanie; Smith, Anthony; Inoue, Madoka; Smith, Tony; Dicker, Bridget; Swain, Andy; Bosley, Emma; Pemberton, Katherine; McKay, Michael; Johnston-Leek, Malcolm; Cameron, Peter; Perkins, Gavin D; Finn, Judith
2016-12-01
The present study aimed to describe and examine similarities and differences in the current service provision and resuscitation protocols of the ambulance services participating in the Aus-ROC Australian and New Zealand out-of-hospital cardiac arrest (OHCA) Epistry. Understanding these similarities and differences is important in identifying ambulance service factors that might explain regional variation in survival of OHCA in the Aus-ROC Epistry. A structured questionnaire was completed by each of the ambulance services participating in the Aus-ROC Epistry. These ambulance services were SA Ambulance Service, Ambulance Victoria, St John Ambulance Western Australia, Queensland Ambulance Service, St John Ambulance NT, St John New Zealand and Wellington Free Ambulance. The survey aimed to describe ambulance service and dispatch characteristics, resuscitation protocols and details of cardiac arrest registries. We observed similarities between services with respect to the treatment of OHCA and dispatch systems. Differences between services were observed in the serviced population; the proportion of paramedics with basic life support, advanced life support or intensive care training skills; the number of OHCA cases attended; guidelines related to withholding or terminating resuscitation attempts; and the variables that might be used to define 'attempted resuscitation'. All seven participating ambulance services were noted to have existing OHCA registries. There is marked variation between ambulance services currently participating in the Aus-ROC Australian and New Zealand OHCA Epistry with respect to workforce characteristics and key variable definitions. This variation between ambulance services might account for a proportion of the regional variation in survival of OHCA. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Protein Quality Control Under Oxidative Stress Conditions
Dahl, Jan-Ulrik; Gray, Michael J.; Jakob, Ursula
2015-01-01
Accumulation of reactive oxygen and chlorine species (RO/CS) is generally regarded to be a toxic and highly undesirable event, which serves as contributing factor in aging and many age-related diseases. However, it is also put to excellent use during host defense, when high levels of RO/CS are produced to kill invading microorganisms and regulate bacterial colonization. Biochemical and cell biological studies of how bacteria and other microorganisms deal with RO/CS have now provided important new insights into the physiological consequences of oxidative stress, the major targets that need protection, and the cellular strategies employed by organisms to mitigate the damage. This review examines the redox-regulated mechanisms by which cells maintain a functional proteome during oxidative stress. We will discuss the well-characterized redox-regulated chaperone Hsp33, and review recent discoveries demonstrating that oxidative stress-specific activation of chaperone function is a much more widespread phenomenon than previously anticipated. New members of this group include the cytosolic ATPase Get3 in yeast, the E. coli protein RidA, and the mammalian protein α2-macroglobin. We will conclude our review with recent evidence showing that inorganic polyphosphate (polyP), whose accumulation significantly increases bacterial oxidative stress resistance, works by a protein-like chaperone mechanism. Understanding the relationship between oxidative and proteotoxic stresses will improve our understanding of both host-microbe interactions and of how mammalian cells combat the damaging side effects of uncontrolled RO/CS production, a hallmark of inflammation. PMID:25698115
A completely automated CAD system for mass detection in a large mammographic database.
Bellotti, R; De Carlo, F; Tangaro, S; Gargano, G; Maggipinto, G; Castellano, M; Massafra, R; Cascio, D; Fauci, F; Magro, R; Raso, G; Lauria, A; Forni, G; Bagnasco, S; Cerello, P; Zanon, E; Cheran, S C; Lopez Torres, E; Bottigli, U; Masala, G L; Oliva, P; Retico, A; Fantacci, M E; Cataldo, R; De Mitri, I; De Nunzio, G
2006-08-01
Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.
Pappinen, Sari; Hermansson, Martin; Kuntsche, Judith; Somerharju, Pentti; Wertz, Philip; Urtti, Arto; Suhonen, Marjukka
2008-04-01
The present report is a part of our continuing efforts to explore the utility of the rat epidermal keratinocyte organotypic culture (ROC) as an alternative model to human skin in transdermal drug delivery and skin irritation studies of new chemical entities and formulations. The aim of the present study was to compare the stratum corneum lipid content of ROC with the corresponding material from human skin. The lipid composition was determined by thin-layer chromatography (TLC) and mass-spectrometry, and the thermal phase transitions of stratum corneum were studied by differential scanning calorimetry (DSC). All major lipid classes of the stratum corneum were present in ROC in a similar ratio as found in human stratum corneum. Compared to human skin, the level of non-hydroxyacid-sphingosine ceramide (NS) was increased in ROC, while alpha-hydroxyacid-phytosphingosine ceramide (AP) and non-hydroxyacid-phytosphingosine ceramides (NP) were absent. Also some alterations in fatty acid profiles of ROC ceramides were noted, e.g., esterified omega-hydroxyacid-sphingosine contained increased levels of oleic acid instead of linoleic acid. The fraction of lipids covalently bound to corneocyte proteins was distinctly lower in ROC compared to human skin, in agreement with the results from DSC. ROC underwent a lipid lamellar order to disorder transition (T2) at a slightly lower temperature (68 degrees C) than human skin (74 degrees C). These differences in stratum corneum lipid composition and the thermal phase transitions may explain the minor differences previously observed in drug permeation between ROC and human skin.
Variations in recollection: the effects of complexity on source recognition.
Parks, Colleen M; Murray, Linda J; Elfman, Kane; Yonelinas, Andrew P
2011-07-01
Whether recollection is a threshold or signal detection process is highly controversial, and the controversy has centered in part on the shape of receiver operating characteristics (ROCs) and z-transformed ROCs (zROCs). U-shaped zROCs observed in tests thought to rely heavily on recollection, such as source memory tests, have provided evidence in favor of the threshold assumption, but zROCs are not always as U-shaped as threshold theory predicts. Source zROCs have been shown to become more linear when the contribution of familiarity to source discriminations is increased, and this may account for the existing results. However, another way in which source zROCs may become more linear is if the recollection threshold begins to break down and recollection becomes more graded and Gaussian. We tested the "graded recollection" account in the current study. We found that increasing stimulus complexity (i.e., changing from single words to sentences) or increasing source complexity (i.e., changing the sources from audio to videos of speakers) resulted in flatter source zROCs. In addition, conditions expected to reduce recollection (i.e., divided attention and amnesia) had comparable effects on source memory in simple and complex conditions, suggesting that differences between simple and complex conditions were due to differences in the nature of recollection, rather than differences in the utility of familiarity. The results suggest that under conditions of high complexity, recollection can appear more graded, and it can produce curved ROCs. The results have implications for measurement models and for current theories of recognition memory.
A diagnostic scoring system for myxedema coma.
Popoveniuc, Geanina; Chandra, Tanu; Sud, Anchal; Sharma, Meeta; Blackman, Marc R; Burman, Kenneth D; Mete, Mihriye; Desale, Sameer; Wartofsky, Leonard
2014-08-01
To develop diagnostic criteria for myxedema coma (MC), a decompensated state of extreme hypothyroidism with a high mortality rate if untreated, in order to facilitate its early recognition and treatment. The frequencies of characteristics associated with MC were assessed retrospectively in patients from our institutions in order to derive a semiquantitative diagnostic point scale that was further applied on selected patients whose data were retrieved from the literature. Logistic regression analysis was used to test the predictive power of the score. Receiver operating characteristic (ROC) curve analysis was performed to test the discriminative power of the score. Of the 21 patients examined, 7 were reclassified as not having MC (non-MC), and they were used as controls. The scoring system included a composite of alterations of thermoregulatory, central nervous, cardiovascular, gastrointestinal, and metabolic systems, and presence or absence of a precipitating event. All 14 of our MC patients had a score of ≥60, whereas 6 of 7 non-MC patients had scores of 25 to 50. A total of 16 of 22 MC patients whose data were retrieved from the literature had a score ≥60, and 6 of 22 of these patients scored between 45 and 55. The odds ratio per each score unit increase as a continuum was 1.09 (95% confidence interval [CI], 1.01 to 1.16; P = .019); a score of 60 identified coma, with an odds ratio of 1.22. The area under the ROC curve was 0.88 (95% CI, 0.65 to 1.00), and the score of 60 had 100% sensitivity and 85.71% specificity. A score ≥60 in the proposed scoring system is potentially diagnostic for MC, whereas scores between 45 and 59 could classify patients at risk for MC.
Required Operational Capability, USMC-ROC-LOG-216.3.5 for the Ration, Cold Weather.
1987-05-06
in operations or training in an arctic environment . b. Organizational Concept. The ration , cold weather will be issued in accordance with established...all services. 2 ROC-ARCTIC 7. TECHNICAL FEASIBILITY AND ENERGY/ ENVIRONMENTAL IMPACTS a. Technical Feasibility. The risk of developing the ration ...r -A1833 963 REQUIRED OPERATIONAL CAPABILITY USMC-ROC-LOG-21635 FOR 1t/1 THE RATION COLD WEATHER(U) MARINE CORPS WASHINGTON DC 86 MAY 87 USMC-ROC-LOG
Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆
Tang, Liansheng; Du, Pang; Wu, Chengqing
2012-01-01
Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484
Rollover Car Crashes with Ejection: A Deadly Combination—An Analysis of 719 Patients
Latifi, Rifat; El-Menyar, Ayman; El-Hennawy, Hany; Al-Thani, Hassan
2014-01-01
Rollover car crashes (ROCs) are serious public safety concerns worldwide. Objective. To determine the incidence and outcomes of ROCs with or without ejection of occupants in the State of Qatar. Methods. A retrospective study of all patients involved in ROCs admitted to Level I trauma center in Qatar (2011-2012). Patients were divided into Group I (ROC with ejection) and Group II (ROC without ejection). Results. A total of 719 patients were evaluated (237 in Group I and 482 in Group II). The mean age in Group I was lower than in Group II (24.3 ± 10.3 versus 29 ± 12.2; P = 0.001). Group I had higher injury severity score and sustained significantly more head, chest, and abdominal injuries in comparison to Group II. The mortality rate was higher in Group I (25% versus 7%; P = 0.001). Group I patients required higher ICU admission rate (P = 0.001). Patients in Group I had a 5-fold increased risk for age-adjusted mortality (OR 5.43; 95% CI 3.11–9.49), P = 0.001). Conclusion. ROCs with ejection are associated with higher rate of morbidity and mortality compared to ROCs without ejection. As an increased number of young Qatari males sustain ROCs with ejection, these findings highlight the need for research-based injury prevention initiatives in the country. PMID:24693231
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Bill Hrybyk Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. In this image, a gathering of Goddard employees watch the ribbon cutting. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Desiree Stover Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Chris Gunn Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office (SSCO). Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. Here, she receives an overview of a robotic console station used to practice satellite servicing activities. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Desiree Stover NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm (visible at top right), a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Bill Hrybyk Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2016-01-06
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... Credit: NASA/Goddard/Chris Gunn NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office (SSCO). Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm (visible above, at right), a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Desiree Stover Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Wang, L M; Zhong, H; Tang, N; Pang, L J; Zhang, C J; He, F
2017-11-24
Objective: To investigate the interaction of Ca(2+) protein TRPC1 and STIM1 in extracellular Ca(2+) -sensing receptor (CaR)-induced extracellular Ca(2+) influx and the production of nitric oxide (NO). Methods: Human umbilical vein endothelial cells (HUVECs) were cultured and incubated with CaR agonist spermine (activating store-operates cation channels (SOC) and receptor-operated channels (ROC)), CaR negative allosteric modulator Calhex231 (blocking SOC, activating ROC) and ROC analogue TPA (activating ROC, blocking SOC), protein kinase C (PKC) inhibitor Ro31-8220, PKCs and PKCμ inhibitor Go6967(activate SOC, blocking ROC), respectively. The interaction of TRPC1 and STIM1 was determined using the immunofluorescence methods. The interaction between TRPC1 and STIM1 were examined by Co-immuno precipitation. The HUVECs were divided into: TRPC1 and STIM1 short hairpin RNA group (shTRPC1+ shSTIM1 group), vehicle-TRPC1+ vehicle-STIM1 group and control group. The cells were incubated with four different treatments under the action of above mentioned interventions, intracellular Ca(2+) concentration ([Ca(2+) ](i)) was detected using the fluorescence Ca(2+) indicator Fura-2/AM, the production of NO was determined by DAF-FM. Results: (1) The expression of TRPC1 and STIM1 proteins levels in HUVECs: Under the confocal microscope, TRPC1 and STIM1 protein expression showed masculine gender, both located in cytoplasm in the normal control group. Post incubation with Calhex231+ TPA, Ro31-8220 and Go6967, TRPC1 and STIM1 positioned in cytoplasm was significantly reduced, and the combined TRPC1 and STIM1 was also significantly reduced. (2) The interaction of TRPC1 and STIM1 in HUVECs: The relative ratios of Calhex231+ TPA+ Spermine+ Ca(2+) group, Ro31-8220+ Spermine+ Ca(2+) group and Go6976+ Spermine+ Ca(2+) group STIM1/TRPC1 and TRPC1/STIM1 were as follows: (25.98±2.17)% and (44.10±4.01)%, (20.85±1.01)% and (46.31±3.47)%, (23.88±2.05)% and (39.65±2.91)%, which were significantly lower than those in the control group (100.00±4.66)% and (100.00±6.40)% and in the Spermine+ Ca(2+) group (106.04±2.45)% and (107.78±2.66)% (all P <0.05). (3) The influence of joint TRPC1 and STIM1 transfection to four different drugs treated HUVECs on [Ca(2+) ](i) and NO generation: The changes of two excitation fluorescence intensity ratio and NO net fluorescence intensity values were consistent, [Ca(2+) ](i) and NO net fluorescence intensity values were significantly lower in the experimental group than the control group and the vehicle group (all P <0.05), while which were similar between the vehicle group and control group (all P >0.05). Conclusions: Our results indicate that TRPC1 and STIM1 jointly regulate CaR-mediated Ca(2+) influx and nitric oxide generation in HUVECs in the form of binary complex.
Barrow, Emma; Evans, D Gareth; McMahon, Ray; Hill, James; Byers, Richard
2011-03-01
Lynch Syndrome is caused by mutations in DNA mismatch repair (MMR) genes. Mutation carrier identification is facilitated by immunohistochemical detection of the MMR proteins MHL1 and MSH2 in tumour tissue and is desirable as colonoscopic screening reduces mortality. However, protein detection by conventional immunohistochemistry (IHC) is subjective, and quantitative techniques are required. Quantum dots (QDs) are novel fluorescent labels that enable quantitative multiplex staining. This study compared their use with quantitative 3,3'-diaminobenzidine (DAB) IHC for the diagnosis of Lynch Syndrome. Tumour sections from 36 mutation carriers and six controls were obtained. These were stained with DAB on an automated platform using antibodies against MLH1 and MSH2. Multiplex QD immunofluorescent staining of the sections was performed using antibodies against MLH1, MSH2 and smooth muscle actin (SMA). Multispectral analysis of the slides was performed. The staining intensity of DAB and QDs was measured in multiple colonic crypts, and the mean intensity scores calculated. Receiver operating characteristic (ROC) curves of staining performance for the identification of mutation carriers were evaluated. For quantitative DAB IHC, the area under the MLH1 ROC curve was 0.872 (95% CI 0.763 to 0.981), and the area under the MSH2 ROC curve was 0.832 (95% CI 0.704 to 0.960). For quantitative QD IHC, the area under the MLH1 ROC curve was 0.812 (95% CI 0.681 to 0.943), and the area under the MSH2 ROC curve was 0.598 (95% CI 0.418 to 0.777). Despite the advantage of QD staining to enable several markers to be measured simultaneously, it is of lower utility than DAB IHC for the identification of MMR mutation carriers. Automated DAB IHC staining and quantitative slide analysis may enable high-throughput IHC.
Visualization of the significance of Receiver Operating Characteristics based on confidence ellipses
NASA Astrophysics Data System (ADS)
Sarlis, Nicholas V.; Christopoulos, Stavros-Richard G.
2014-03-01
The Receiver Operating Characteristics (ROC) is used for the evaluation of prediction methods in various disciplines like meteorology, geophysics, complex system physics, medicine etc. The estimation of the significance of a binary prediction method, however, remains a cumbersome task and is usually done by repeating the calculations by Monte Carlo. The FORTRAN code provided here simplifies this problem by evaluating the significance of binary predictions for a family of ellipses which are based on confidence ellipses and cover the whole ROC space. Catalogue identifier: AERY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AERY_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 11511 No. of bytes in distributed program, including test data, etc.: 72906 Distribution format: tar.gz Programming language: FORTRAN. Computer: Any computer supporting a GNU FORTRAN compiler. Operating system: Linux, MacOS, Windows. RAM: 1Mbyte Classification: 4.13, 9, 14. Nature of problem: The Receiver Operating Characteristics (ROC) is used for the evaluation of prediction methods in various disciplines like meteorology, geophysics, complex system physics, medicine etc. The estimation of the significance of a binary prediction method, however, remains a cumbersome task and is usually done by repeating the calculations by Monte Carlo. The FORTRAN code provided here simplifies this problem by evaluating the significance of binary predictions for a family of ellipses which are based on confidence ellipses and cover the whole ROC space. Solution method: Using the statistics of random binary predictions for a given value of the predictor threshold ɛt, one can construct the corresponding confidence ellipses. The envelope of these corresponding confidence ellipses is estimated when ɛt varies from 0 to 1. This way a new family of ellipses is obtained, named k-ellipses, which covers the whole ROC plane and leads to a well defined Area Under the Curve (AUC). For the latter quantity, Mason and Graham [1] have shown that it follows the Mann-Whitney U-statistics [2] which can be applied [3] for the estimation of the statistical significance of each k-ellipse. As the transformation is invertible, any point on the ROC plane corresponds to a unique value of k, thus to a unique p-value to obtain this point by chance. The present FORTRAN code provides this p-value field on the ROC plane as well as the k-ellipses corresponding to the (p=)10%, 5% and 1% significance levels using as input the number of the positive (P) and negative (Q) cases to be predicted. Unusual features: In some machines, the compiler directive -O2 or -O3 should be used to avoid NaN’s in some points of the p-field along the diagonal. Running time: Depending on the application, e.g., 4s for an Intel(R) Core(TM)2 CPU E7600 at 3.06 GHz with 2 GB RAM for the examples presented here References: [1] S.J. Mason, N.E. Graham, Quart. J. Roy. Meteor. Soc. 128 (2002) 2145. [2] H.B. Mann, D.R. Whitney, Ann. Math. Statist. 18 (1947) 50. [3] L.C. Dinneen, B.C. Blakesley, J. Roy. Stat. Soc. Ser. C Appl. Stat. 22 (1973) 269.
Plasma long non-coding RNA BACE1 as a novel biomarker for diagnosis of Alzheimer disease.
Feng, Liang; Liao, Yu-Ting; He, Jin-Cai; Xie, Cheng-Long; Chen, Si-Yan; Fan, Hui-Hui; Su, Zhi-Peng; Wang, Zhen
2018-01-09
Long non-coding RNA (LncRNA) have been reported to be involved in the pathogenesis of neurodegenerative diseases, but whether it can serve as a biomarker for Alzheimer disease (AD) is not yet known. The present study selected four specific LncRNA (17A, 51A, BACE1 and BC200) as possible AD biomarker. RT-qPCR was performed to validate the LncRNA. Receiver operating characteristic curve (ROC) and area under the ROC curve (AUC) were applied to study the potential of LncRNA as a biomarker in a population of 88 AD patients and 72 control individuals. We found that the plasma LncRNA BACE1 level of AD patients was significantly higher than that of healthy controls (p = 0.006). Plasma level of LncRNA 17A, 51A and BC200 did not show a significant difference between two groups (p = 0.098, p = 0.204 and p = 0.232, respectively). ROC curve analysis showed that LncRNA BACE1 was the best candidate of these LncRNA (95% CI: 0.553-0.781, p = 0.003). In addition, no correlation was found for expression of these LncRNA in both control and AD groups with age or MMSE scale (p > 0.05). Our present study compared the plasma level of four LncRNA between AD and non-AD patients, and found that the level of the BACE1 is increased in the plasma of AD patients and have a high specificity (88%) for AD, indicating BACE1 may be a potential candidate biomarker to predict AD.
Liu, Datong; Peng, Yu; Peng, Xiyuan
2018-01-01
Effective anomaly detection of sensing data is essential for identifying potential system failures. Because they require no prior knowledge or accumulated labels, and provide uncertainty presentation, the probability prediction methods (e.g., Gaussian process regression (GPR) and relevance vector machine (RVM)) are especially adaptable to perform anomaly detection for sensing series. Generally, one key parameter of prediction models is coverage probability (CP), which controls the judging threshold of the testing sample and is generally set to a default value (e.g., 90% or 95%). There are few criteria to determine the optimal CP for anomaly detection. Therefore, this paper designs a graphic indicator of the receiver operating characteristic curve of prediction interval (ROC-PI) based on the definition of the ROC curve which can depict the trade-off between the PI width and PI coverage probability across a series of cut-off points. Furthermore, the Youden index is modified to assess the performance of different CPs, by the minimization of which the optimal CP is derived by the simulated annealing (SA) algorithm. Experiments conducted on two simulation datasets demonstrate the validity of the proposed method. Especially, an actual case study on sensing series from an on-orbit satellite illustrates its significant performance in practical application. PMID:29587372
Wu, Xia; Li, Juan; Ayutyanont, Napatkamon; Protas, Hillary; Jagust, William; Fleisher, Adam; Reiman, Eric; Yao, Li; Chen, Kewei
2013-01-01
Given a single index, the receiver operational characteristic (ROC) curve analysis is routinely utilized for characterizing performances in distinguishing two conditions/groups in terms of sensitivity and specificity. Given the availability of multiple data sources (referred to as multi-indices), such as multimodal neuroimaging data sets, cognitive tests, and clinical ratings and genomic data in Alzheimer’s disease (AD) studies, the single-index-based ROC underutilizes all available information. For a long time, a number of algorithmic/analytic approaches combining multiple indices have been widely used to simultaneously incorporate multiple sources. In this study, we propose an alternative for combining multiple indices using logical operations, such as “AND,” “OR,” and “at least n” (where n is an integer), to construct multivariate ROC (multiV-ROC) and characterize the sensitivity and specificity statistically associated with the use of multiple indices. With and without the “leave-one-out” cross-validation, we used two data sets from AD studies to showcase the potentially increased sensitivity/specificity of the multiV-ROC in comparison to the single-index ROC and linear discriminant analysis (an analytic way of combining multi-indices). We conclude that, for the data sets we investigated, the proposed multiV-ROC approach is capable of providing a natural and practical alternative with improved classification accuracy as compared to univariate ROC and linear discriminant analysis.
Wu, Xia; Li, Juan; Ayutyanont, Napatkamon; Protas, Hillary; Jagust, William; Fleisher, Adam; Reiman, Eric; Yao, Li; Chen, Kewei
2014-01-01
Given a single index, the receiver operational characteristic (ROC) curve analysis is routinely utilized for characterizing performances in distinguishing two conditions/groups in terms of sensitivity and specificity. Given the availability of multiple data sources (referred to as multi-indices), such as multimodal neuroimaging data sets, cognitive tests, and clinical ratings and genomic data in Alzheimer’s disease (AD) studies, the single-index-based ROC underutilizes all available information. For a long time, a number of algorithmic/analytic approaches combining multiple indices have been widely used to simultaneously incorporate multiple sources. In this study, we propose an alternative for combining multiple indices using logical operations, such as “AND,” “OR,” and “at least n” (where n is an integer), to construct multivariate ROC (multiV-ROC) and characterize the sensitivity and specificity statistically associated with the use of multiple indices. With and without the “leave-one-out” cross-validation, we used two data sets from AD studies to showcase the potentially increased sensitivity/specificity of the multiV-ROC in comparison to the single-index ROC and linear discriminant analysis (an analytic way of combining multi-indices). We conclude that, for the data sets we investigated, the proposed multiV-ROC approach is capable of providing a natural and practical alternative with improved classification accuracy as compared to univariate ROC and linear discriminant analysis. PMID:23702553
Comparative evaluation of two asthma care quality measures among Medicaid beneficiaries.
Samnaliev, Mihail; Baxter, Jeffrey D; Clark, Robin E
2009-05-01
The relative performance of asthma care quality measures has not been evaluated in Medicaid populations. Using complete claims and pharmaceutical data for 19,076 patients with persistent asthma (based on Health Effectiveness and Data Information Set criteria) in five Medicaid populations, we compared the following two measures of asthma care quality: filling prescriptions for controller asthma medications within 1 year and the ratio of controller medication to the total number of asthma medication prescriptions filled within 1 year. We calculated whether meeting each quality measure was associated with decreased odds of emergency department (ED) treatment episodes. We then compared the odds ratios, receiver operating characteristic (ROC) curves, and deviances between models, using each measure to predict ED utilization in Medicaid populations. Although meeting each measure was associated with lower odds of ED utilization, this decrease was larger if the controller asthma medication measure was met rather than the ratio measure. Additionally, models using the controller medication measure had greater areas under the ROC curve and smaller deviances than models using the ratio measure. Both administrative measures of asthma care quality were associated with lower odds of ED utilization. The controller medication measure of asthma care quality may be better than the ratio measure in relation to emergency asthma care utilization by Medicaid beneficiaries.
Smith, Andrew M; Wells, Gary L; Lindsay, R C L; Penrod, Steven D
2017-04-01
Receiver Operating Characteristic (ROC) analysis has recently come in vogue for assessing the underlying discriminability and the applied utility of lineup procedures. Two primary assumptions underlie recommendations that ROC analysis be used to assess the applied utility of lineup procedures: (a) ROC analysis of lineups measures underlying discriminability, and (b) the procedure that produces superior underlying discriminability produces superior applied utility. These same assumptions underlie a recently derived diagnostic-feature detection theory, a theory of discriminability, intended to explain recent patterns observed in ROC comparisons of lineups. We demonstrate, however, that these assumptions are incorrect when ROC analysis is applied to lineups. We also demonstrate that a structural phenomenon of lineups, differential filler siphoning, and not the psychological phenomenon of diagnostic-feature detection, explains why lineups are superior to showups and why fair lineups are superior to biased lineups. In the process of our proofs, we show that computational simulations have assumed, unrealistically, that all witnesses share exactly the same decision criteria. When criterial variance is included in computational models, differential filler siphoning emerges. The result proves dissociation between ROC curves and underlying discriminability: Higher ROC curves for lineups than for showups and for fair than for biased lineups despite no increase in underlying discriminability. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide
ERIC Educational Resources Information Center
Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.
2017-01-01
Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…
Neyman-Pearson classification algorithms and NP receiver operating characteristics
Tong, Xin; Feng, Yang; Li, Jingyi Jessica
2018-01-01
In many binary classification applications, such as disease diagnosis and spam detection, practitioners commonly face the need to limit type I error (that is, the conditional probability of misclassifying a class 0 observation as class 1) so that it remains below a desired threshold. To address this need, the Neyman-Pearson (NP) classification paradigm is a natural choice; it minimizes type II error (that is, the conditional probability of misclassifying a class 1 observation as class 0) while enforcing an upper bound, α, on the type I error. Despite its century-long history in hypothesis testing, the NP paradigm has not been well recognized and implemented in classification schemes. Common practices that directly limit the empirical type I error to no more than α do not satisfy the type I error control objective because the resulting classifiers are likely to have type I errors much larger than α, and the NP paradigm has not been properly implemented in practice. We develop the first umbrella algorithm that implements the NP paradigm for all scoring-type classification methods, such as logistic regression, support vector machines, and random forests. Powered by this algorithm, we propose a novel graphical tool for NP classification methods: NP receiver operating characteristic (NP-ROC) bands motivated by the popular ROC curves. NP-ROC bands will help choose α in a data-adaptive way and compare different NP classifiers. We demonstrate the use and properties of the NP umbrella algorithm and NP-ROC bands, available in the R package nproc, through simulation and real data studies. PMID:29423442
Neyman-Pearson classification algorithms and NP receiver operating characteristics.
Tong, Xin; Feng, Yang; Li, Jingyi Jessica
2018-02-01
In many binary classification applications, such as disease diagnosis and spam detection, practitioners commonly face the need to limit type I error (that is, the conditional probability of misclassifying a class 0 observation as class 1) so that it remains below a desired threshold. To address this need, the Neyman-Pearson (NP) classification paradigm is a natural choice; it minimizes type II error (that is, the conditional probability of misclassifying a class 1 observation as class 0) while enforcing an upper bound, α, on the type I error. Despite its century-long history in hypothesis testing, the NP paradigm has not been well recognized and implemented in classification schemes. Common practices that directly limit the empirical type I error to no more than α do not satisfy the type I error control objective because the resulting classifiers are likely to have type I errors much larger than α, and the NP paradigm has not been properly implemented in practice. We develop the first umbrella algorithm that implements the NP paradigm for all scoring-type classification methods, such as logistic regression, support vector machines, and random forests. Powered by this algorithm, we propose a novel graphical tool for NP classification methods: NP receiver operating characteristic (NP-ROC) bands motivated by the popular ROC curves. NP-ROC bands will help choose α in a data-adaptive way and compare different NP classifiers. We demonstrate the use and properties of the NP umbrella algorithm and NP-ROC bands, available in the R package nproc, through simulation and real data studies.
Anxiety and Depression Screening for Youth in a Primary Care Population
Katon, Wayne; Joan, Russo; Richardson, Laura; McCauley, Elizabeth; Lozano, Paula
2008-01-01
Objective Prior studies have shown a low rate of accurate identification by primary care physicians of mental health disorders in youth. This study tested the psychometric properties of two brief mental health screening questionnaires, the Mood and Feelings Questionnaire – Short Form (MFQ-SF) and Childhood Anxiety Sensitivity Index (ASI), in a large sample of youth. Methods In a sample of 1375 youth age 11 to 17 (779 with asthma, 596 randomly selected controls) enrolled in an HMO, the psychometric properties (optimum cutoffs on Receiver Operating Curve (ROC) curves, sensitivity, specificity, positive and negative predictive values) of two brief anxiety and depression screens were examined versus a “gold standard” structured psychiatric interview. Results Both the MFQ-SF and ASI performed well on ROC analysis for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better on ROC analysis than the ASI for youth with major depression (area under the curve of 0.84 vs 0.77). For screening youth with anxiety disorders ROC curves showed that both the MFQ-SF and ASI only performed in the fair range (area under the curve of 0.76). Conclusion The MFQ-SF and ASI are two relatively brief questionnaires that performed well for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better than the ASI for screening youth with major depression. Use of these instruments could increase the accuracy of identification of mental health disorders in youth by primary care physicians. PMID:18501865
Bayes’ theorem, the ROC diagram and reference values: Definition and use in clinical diagnosis
Kallner, Anders
2017-01-01
Medicine is diagnosis, treatment and care. To diagnose is to consider the probability of the cause of discomfort experienced by the patient. The physician may face many options and all decisions are liable to uncertainty to some extent. The rational action is to perform selected tests and thereby increase the pre-test probability to reach a superior post-test probability of a particular option. To draw the right conclusions from a test, certain background information about the performance of the test is necessary. We set up a partially artificial dataset with measured results obtained from the laboratory information system and simulated diagnosis attached. The dataset is used to explore the use of contingency tables with a unique graphic design and software to establish and compare ROC graphs. The loss of information in the ROC curve is compensated by a cumulative data analysis (CDA) plot linked to a display of the efficiency and predictive values. A standard for the contingency table is suggested and the use of dynamic reference intervals discussed. PMID:29209139
Development of infrared thermal imager for dry eye diagnosis
NASA Astrophysics Data System (ADS)
Chiang, Huihua Kenny; Chen, Chih Yen; Cheng, Hung You; Chen, Ko-Hua; Chang, David O.
2006-08-01
This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.
Cognitive-motivational deficits in ADHD: development of a classification system.
Gupta, Rashmi; Kar, Bhoomika R; Srinivasan, Narayanan
2011-01-01
The classification systems developed so far to detect attention deficit/hyperactivity disorder (ADHD) do not have high sensitivity and specificity. We have developed a classification system based on several neuropsychological tests that measure cognitive-motivational functions that are specifically impaired in ADHD children. A total of 240 (120 ADHD children and 120 healthy controls) children in the age range of 6-9 years and 32 Oppositional Defiant Disorder (ODD) children (aged 9 years) participated in the study. Stop-Signal, Task-Switching, Attentional Network, and Choice Delay tests were administered to all the participants. Receiver operating characteristic (ROC) analysis indicated that percentage choice of long-delay reward best classified the ADHD children from healthy controls. Single parameters were not helpful in making a differential classification of ADHD with ODD. Multinominal logistic regression (MLR) was performed with multiple parameters (data fusion) that produced improved overall classification accuracy. A combination of stop-signal reaction time, posterror-slowing, mean delay, switch cost, and percentage choice of long-delay reward produced an overall classification accuracy of 97.8%; with internal validation, the overall accuracy was 92.2%. Combining parameters from different tests of control functions not only enabled us to accurately classify ADHD children from healthy controls but also in making a differential classification with ODD. These results have implications for the theories of ADHD.
NASA Astrophysics Data System (ADS)
Kohli, Akshay; Robinson, John W.; Ryan, John; McEntee, Mark F.; Brennan, Patrick C.
2011-03-01
The purpose of this study is to explore whether reader characteristics are linked to heightened levels of diagnostic performance in chest radiology using receiver operating characteristic (ROC) and jackknife free response ROC (JAFROC) methodologies. A set of 40 postero-anterior chest radiographs was developed, of which 20 were abnormal containing one or more simulated nodules, of varying subtlety. Images were independently reviewed by 12 boardcertified radiologists including six chest specialists. The observer performance was measured in terms of ROC and JAFROC scores. For the ROC analysis, readers were asked to rate their degree of suspicion for the presence of nodules by using a confidence rating scale (1-6). JAFROC analysis required the readers to locate and rate as many suspicious areas as they wished using the same scale and resultant data were used to generate Az and FOM scores for ROC and JAFROC analyses respectively. Using Pearson methods, scores of performance were correlated with 7 reader characteristics recorded using a questionnaire. JAFROC analysis showed that improved reader performance was significantly (p<=0.05) linked with chest specialty (p<0.03), hours per week reading chest radiographs (p<0.03) and chest readings per year (p<0.04). ROC analyses demonstrated only one significant relationship, hours per week reading chest radiographs (p<0.02).The results of this study have shown that radiologist's performance in the detection of pulmonary nodules on radiographs is significantly linked to chest specialty, hours reading per week and number of radiographs read per year. Also, JAFROC is a more powerful predictor of performance as compared to ROC.
Morrison, Laurie J; Nichol, Graham; Rea, Thomas D; Christenson, Jim; Callaway, Clifton W; Stephens, Shannon; Pirrallo, Ronald G; Atkins, Dianne L; Davis, Daniel P; Idris, Ahamed H; Newgard, Craig
2008-08-01
To describe the development, design and consequent scientific implications of the Resuscitation Outcomes Consortium (ROC) population-based registry; ROC Epistry-Cardiac Arrest. The ROC Epistry--Cardiac Arrest is designed as a prospective population-based registry of all Emergency Medical Services (EMSs)-attended 9-1-1 calls for patients with out-of-hospital cardiac arrest occurring in the geographical area described by the eight US and three Canadian regions. The dataset was derived by an North American interdisciplinary steering committee. Enrolled cases include individuals of all ages who experience cardiac arrest outside the hospital, with evaluation by organized EMS personnel and: (a) attempts at external defibrillation (by lay responders or emergency personnel), or chest compressions by organized EMS personnel; (b) were pulseless but did not receive attempts to defibrillate or CPR by EMS personnel. Selected data items are categorized as mandatory or optional and undergo revisions approximately every 12 months. Where possible all definitions are referenced to existing literature. Where a common definition did not exist one was developed. Optional items include standardized CPR process data elements. It is anticipated the ROC Epistry--Cardiac Arrest will enroll between approximately 9000 and 13,500 treated all rhythm arrests and 4000 and 5000 ventricular fibrillation arrests annually and approximately 8000 EMS-attended but untreated arrests. We describe the rationale, development, design and future implications of the ROC Epistry--Cardiac Arrest. This paper will serve as the reference for subsequent ROC manuscripts and for the common data elements captured in both ROC Epistry--Cardiac Arrest and the ROC trials.
Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.
2014-01-01
Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643
Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G
2014-01-01
Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.
Koen, Joshua D; Barrett, Frederick S; Harlow, Iain M; Yonelinas, Andrew P
2017-08-01
Signal-detection theory, and the analysis of receiver-operating characteristics (ROCs), has played a critical role in the development of theories of episodic memory and perception. The purpose of the current paper is to present the ROC Toolbox. This toolbox is a set of functions written in the Matlab programming language that can be used to fit various common signal detection models to ROC data obtained from confidence rating experiments. The goals for developing the ROC Toolbox were to create a tool (1) that is easy to use and easy for researchers to implement with their own data, (2) that can flexibly define models based on varying study parameters, such as the number of response options (e.g., confidence ratings) and experimental conditions, and (3) that provides optimal routines (e.g., Maximum Likelihood estimation) to obtain parameter estimates and numerous goodness-of-fit measures.The ROC toolbox allows for various different confidence scales and currently includes the models commonly used in recognition memory and perception: (1) the unequal variance signal detection (UVSD) model, (2) the dual process signal detection (DPSD) model, and (3) the mixture signal detection (MSD) model. For each model fit to a given data set the ROC toolbox plots summary information about the best fitting model parameters and various goodness-of-fit measures. Here, we present an overview of the ROC Toolbox, illustrate how it can be used to input and analyse real data, and finish with a brief discussion on features that can be added to the toolbox.
Binary ROCs in Perception and Recognition Memory Are Curved
ERIC Educational Resources Information Center
Dube, Chad; Rotello, Caren M.
2012-01-01
In recognition memory, a classic finding is that receiver operating characteristics (ROCs) are curvilinear. This has been taken to support the fundamental assumptions of signal detection theory (SDT) over discrete-state models such as the double high-threshold model (2HTM), which predicts linear ROCs. Recently, however, Broder and Schutz (2009)…
Design and Optimization of the SPOT Primary Mirror Segment
NASA Technical Reports Server (NTRS)
Budinoff, Jason G.; Michaels, Gregory J.
2005-01-01
The 3m Spherical Primary Optical Telescope (SPOT) will utilize a single ring of 0.86111 point-to-point hexagonal mirror segments. The f2.85 spherical mirror blanks will be fabricated by the same replication process used for mass-produced commercial telescope mirrors. Diffraction-limited phasing will require segment-to-segment radius of curvature (ROC) variation of approx.1 micron. Low-cost, replicated segment ROC variations are estimated to be almost 1 mm, necessitating a method for segment ROC adjustment & matching. A mechanical architecture has been designed that allows segment ROC to be adjusted up to 400 microns while introducing a minimum figure error, allowing segment-to-segment ROC matching. A key feature of the architecture is the unique back profile of the mirror segments. The back profile of the mirror was developed with shape optimization in MSC.Nastran(TradeMark) using optical performance response equations written with SigFit. A candidate back profile was generated which minimized ROC-adjustment-induced surface error while meeting the constraints imposed by the fabrication method. Keywords: optimization, radius of curvature, Pyrex spherical mirror, Sigfit
Awan, Shaheen N; Roy, Nelson; Zhang, Dong; Cohen, Seth M
2016-03-01
The purposes of this study were to (1) evaluate the performance of the Cepstral Spectral Index of Dysphonia (CSID--a multivariate estimate of dysphonia severity) as a potential screening tool for voice disorder identification and (2) identify potential clinical cutoff scores to classify voice-disordered cases versus controls. Subjects were 332 men and women (116 men, 216 women) comprised of subjects who presented to a physician with a voice-related complaint and a group of non-voice-related control subjects. Voice-disordered cases versus controls were initially defined via three reference standards: (1) auditory-perceptual judgment (dysphonia +/-); (2) Voice Handicap Index (VHI) score (VHI +/-); and (3) laryngoscopic description (laryngoscopic +/-). Speech samples were analyzed using the Analysis of Dysphonia in Speech and Voice program. Cepstral and spectral measures were combined into a CSID multivariate formula which estimated dysphonia severity for Rainbow Passage samples (i.e., the CSIDR). The ability of the CSIDR to accurately classify cases versus controls in relation to each reference standard was evaluated via a combination of logistic regression and receiver operating characteristic (ROC) analyses. The ability of the CSIDR to discriminate between cases and controls was represented by the "area under the ROC curve" (AUC). ROC classification of dysphonia-positive cases versus controls resulted in a strong AUC = 0.85. A CSIDR cutoff of ≈24 achieved the best balance between sensitivity and specificity, whereas a more liberal cutoff score of ≈19 resulted in higher sensitivity while maintaining respectable specificity which may be preferred for screening purposes. Weaker but adequate AUCs = 0.75 and 0.73 were observed for the classification of VHI-positive and laryngoscopic-positive cases versus controls, respectively. Logistic regression analyses indicated that subject age may be a significant covariate in the discrimination of dysphonia-positive and VHI-positive cases versus controls. The CSIDR can provide a strong level of accuracy for the classification of voice-disordered cases versus controls, particularly when auditory-perceptual judgment is used as the reference standard. Although users often focus on a cutoff score that achieves a balance between sensitivity and specificity, more liberal cutoffs for screening purposes versus conservative cutoffs when cost or risk of further evaluation is deemed to be high should also be considered. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Oeckl, Patrick; Steinacker, Petra; von Arnim, Christine A F; Straub, Sarah; Nagl, Magdalena; Feneberg, Emily; Weishaupt, Jochen H; Ludolph, Albert C; Otto, Markus
2014-11-07
The impairment of the ubiquitin-proteasome system (UPS) is thought to be an early event in neurodegeneration, and monitoring UPS alterations might serve as a disease biomarker. Our aim was to establish an alternate method to antibody-based assays for the selective measurement of free monoubiquitin in cerebrospinal fluid (CSF). Free monoubiquitin was measured with liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MS/MS) in CSF of patients with Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), behavioral variant of frontotemporal dementia (bvFTD), Creutzfeldt-Jakob disease (CJD), Parkinson's disease (PD), primary progressive aphasia (PPA), and progressive supranuclear palsy (PSP). The LC-MS/MS method showed excellent intra- and interassay precision (4.4-7.4% and 4.9-10.3%) and accuracy (100-107% and 100-106%). CSF ubiquitin concentration was increased compared with that of controls (33.0 ± 9.7 ng/mL) in AD (47.5 ± 13.1 ng/mL, p < 0.05) and CJD patients (171.5 ± 103.5 ng/mL, p < 0.001) but not in other neurodegenerative diseases. Receiver operating characteristic curve (ROC) analysis of AD vs control patients revealed an area under the curve (AUC) of 0.832, and the specificity and sensitivity were 75 and 75%, respectively. ROC analysis of AD and FTLD patients yielded an AUC of 0.776, and the specificity and sensitivity were 53 and 100%, respectively. In conclusion, our LC-MS/MS method may facilitate ubiquitin determination to a broader community and might help to discriminate AD, CJD, and FTLD patients.
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office (SSCO). Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. Here, she receives an overview of a robotic console station used to practice satellite servicing activities. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Chris Gunn Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. In this image, Sen. Mikulski receives an overview of the Asteroid Redirect Mission in front of mockups of the asteroid and capture vehicle. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Bill Hrybyk Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office (SSCO). In this image, she is joined by Chris Scolese, Goddard Center Director (right) and Frank Cepollina, Associate Director of the SSCO (left). Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Chris Gunn Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2016-01-06
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office (SSCO). In this image, she is joined by Chris Scolese, Goddard Center Director (right) and Frank Cepollina, Associate Director of the SSCO (left). Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Chris Gunn Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office. Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. In this image, a gathering of Goddard employees await the arrival of Sen. Mikulski to the facility. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Desiree Stover Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Senator Barbara Mikulski Visits NASA Goddard
2017-12-08
Sen. Barbara Mikulski participated in a ribbon cutting at NASA’s Goddard Space Flight Center on January 6th, 2016, to officially open the new Robotic Operations Center (ROC) developed by the Satellite Servicing Capabilities Office (SSCO). Within the ROC's black walls, NASA is testing technologies and operational procedures for science and exploration missions, including the Restore-L satellite servicing mission and also the Asteroid Redirect Mission. In this image, Sen. Mikulski receives an overview of NASA’s satellite servicing efforts from Benjamin Reed, deputy program manager of SSCO. During her tour of the ROC, Sen. Mikulski saw first-hand an early version of the NASA Servicing Arm, a 2-meter-class robot with the dexterity to grasp and refuel a satellite on orbit. She also heard a description of Raven, a payload launching to the International Space Station that will demonstrate real-time, relative space navigation technology. The robotic technologies that NASA is developing within the ROC also support the Journey to Mars. Learn more about NASA’s satellite servicing technologies at ssco.gsfc.nasa.gov/. Image credit: NASA/Desiree Stover Read more: www.nasa.gov/feature/goddard/2016/maryland-sen-barbara-mi... NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Clinical evaluation of JPEG2000 compression for digital mammography
NASA Astrophysics Data System (ADS)
Sung, Min-Mo; Kim, Hee-Joung; Kim, Eun-Kyung; Kwak, Jin-Young; Yoo, Jae-Kyung; Yoo, Hyung-Sik
2002-06-01
Medical images, such as computed radiography (CR), and digital mammographic images will require large storage facilities and long transmission times for picture archiving and communications system (PACS) implementation. American College of Radiology and National Equipment Manufacturers Association (ACR/NEMA) group is planning to adopt a JPEG2000 compression algorithm in digital imaging and communications in medicine (DICOM) standard to better utilize medical images. The purpose of the study was to evaluate the compression ratios of JPEG2000 for digital mammographic images using peak signal-to-noise ratio (PSNR), receiver operating characteristic (ROC) analysis, and the t-test. The traditional statistical quality measures such as PSNR, which is a commonly used measure for the evaluation of reconstructed images, measures how the reconstructed image differs from the original by making pixel-by-pixel comparisons. The ability to accurately discriminate diseased cases from normal cases is evaluated using ROC curve analysis. ROC curves can be used to compare the diagnostic performance of two or more reconstructed images. The t test can be also used to evaluate the subjective image quality of reconstructed images. The results of the t test suggested that the possible compression ratios using JPEG2000 for digital mammographic images may be as much as 15:1 without visual loss or with preserving significant medical information at a confidence level of 99%, although both PSNR and ROC analyses suggest as much as 80:1 compression ratio can be achieved without affecting clinical diagnostic performance.
Computer-Based Image Analysis for Plus Disease Diagnosis in Retinopathy of Prematurity
Wittenberg, Leah A.; Jonsson, Nina J.; Chan, RV Paul; Chiang, Michael F.
2014-01-01
Presence of plus disease in retinopathy of prematurity (ROP) is an important criterion for identifying treatment-requiring ROP. Plus disease is defined by a standard published photograph selected over 20 years ago by expert consensus. However, diagnosis of plus disease has been shown to be subjective and qualitative. Computer-based image analysis, using quantitative methods, has potential to improve the objectivity of plus disease diagnosis. The objective was to review the published literature involving computer-based image analysis for ROP diagnosis. The PubMed and Cochrane library databases were searched for the keywords “retinopathy of prematurity” AND “image analysis” AND/OR “plus disease.” Reference lists of retrieved articles were searched to identify additional relevant studies. All relevant English-language studies were reviewed. There are four main computer-based systems, ROPtool (AU ROC curve, plus tortuosity 0.95, plus dilation 0.87), RISA (AU ROC curve, arteriolar TI 0.71, venular diameter 0.82), Vessel Map (AU ROC curve, arteriolar dilation 0.75, venular dilation 0.96), and CAIAR (AU ROC curve, arteriole tortuosity 0.92, venular dilation 0.91), attempting to objectively analyze vessel tortuosity and dilation in plus disease in ROP. Some of them show promise for identification of plus disease using quantitative methods. This has potential to improve the diagnosis of plus disease, and may contribute to the management of ROP using both traditional binocular indirect ophthalmoscopy and image-based telemedicine approaches. PMID:21366159
Kengkla, K; Charoensuk, N; Chaichana, M; Puangjan, S; Rattanapornsompong, T; Choorassamee, J; Wilairat, P; Saokaew, S
2016-05-01
Extended spectrum β-lactamase-producing Escherichia coli (ESBL-EC) has important implications for infection control and empiric antibiotic prescribing. This study aims to develop a risk scoring system for predicting ESBL-EC infection based on local epidemiology. The study retrospectively collected eligible patients with a positive culture for E. coli during 2011 to 2014. The risk scoring system was developed using variables independently associated with ESBL-EC infection through logistic regression-based prediction. Area under the receiver-operator characteristic curve (AuROC) was determined to confirm the prediction power of the model. Predictors for ESBL-EC infection were male gender [odds ratio (OR): 1.53], age ≥55 years (OR: 1.50), healthcare-associated infection (OR: 3.21), hospital-acquired infection (OR: 2.28), sepsis (OR: 1.79), prolonged hospitalization (OR: 1.88), history of ESBL infection within one year (OR: 7.88), prior use of broad-spectrum cephalosporins within three months (OR: 12.92), and prior use of other antibiotics within three months (OR: 2.14). Points scored ranged from 0 to 47, and were divided into three groups based on diagnostic performance parameters: low risk (score: 0-8; 44.57%), moderate risk (score: 9-11; 21.85%) and high risk (score: ≥12; 33.58%). The model displayed moderate power of prediction (AuROC: 0.773; 95% confidence interval: 0.742-0.805) and good calibration (Hosmer-Lemeshow χ(2) = 13.29; P = 0.065). This tool may optimize the prescribing of empirical antibiotic therapy, minimize time to identify patients, and prevent spreading of ESBL-EC. Prior to adoption into routine clinical practice, further validation study of the tool is needed. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Eid, Wael E; Pottala, James V
2010-01-01
To develop a receiver operating characteristic (ROC) curve of glycosylated hemoglobin (HbA1c) for diagnosing diabetes mellitus within a chronic disease management system. A case-control study including medical records from January 1, 1997, to December 31, 2005, was conducted at the Sioux Falls Veterans Affairs Medical Center. Medical records for the case group (patients with diabetes) were selected based on 1 of 3 criteria: International Classification of Diseases, Ninth Revision, Clinical Modification or Current Procedural Terminology codes specific for type 1 and type 2 diabetes; patients' use of medications (oral hypoglycemic agents, antidiabetes agents, or insulin); or results from random blood or plasma glucose tests (at least 2 measurements of blood glucose > or = 200 mg/dL). Records for the control group were selected based on patients having HbA1c measured, but not meeting the above diagnostic criteria for diabetes during the study period. Records for cases and controls were randomly frequency-matched, one-to-one. The control group was randomly divided into 5 sets of an equal number of records. Five sets of an equal number of cases were then randomly selected from the total number of cases. Each test data set included 1 case group and 1 control group, resulting in 5 independent data sets. In total, 5040 patient records met the case definition in the diabetes registry. Records of 15 patients who were prescribed metformin only, but did not meet any other case criteria, were reviewed and excluded after determining the patients were not diabetic. The control group consisted of 5 sets of 616 records each (totaling 3080 records), and the case group consisted of 5 sets of 616 records each (totaling 3080 records). Thus, each of the 5 independent data sets of 1 case group and 1 control group contained 1232 records. The case group was predominantly composed of white men (mean age, 69 years; mean body mass index, 31 kg/m2). Demographic data were similar for control patients. The ROC curve revealed that a HbA1c > or = 6.3% (mean + 1 SD) offered the most accurate cutoff value for diagnosing type 2 diabetes mellitus, with the following statistical values: C statistic, 0.78; sensitivity, 70%; specificity, 85%; and positive likelihood ratio, 4.6 (95% confidence interval, 4.2-5.0). A HbA1c value > or = 6.3% may be a useful benchmark for diagnosing diabetes mellitus within a chronic disease management system and may be a useful tool for monitoring high-risk populations.
PRROC: computing and visualizing precision-recall and receiver operating characteristic curves in R.
Grau, Jan; Grosse, Ivo; Keilwagen, Jens
2015-08-01
Precision-recall (PR) and receiver operating characteristic (ROC) curves are valuable measures of classifier performance. Here, we present the R-package PRROC, which allows for computing and visualizing both PR and ROC curves. In contrast to available R-packages, PRROC allows for computing PR and ROC curves and areas under these curves for soft-labeled data using a continuous interpolation between the points of PR curves. In addition, PRROC provides a generic plot function for generating publication-quality graphics of PR and ROC curves. © The Author 2015. Published by Oxford University Press.
Effectiveness of computer aided detection for solitary pulmonary nodules
NASA Astrophysics Data System (ADS)
Yan, Jiayong; Li, Wenjie; Du, Xiangying; Lu, Huihai; Xu, Jianrong; Xu, Mantao; Rong, Dongdong
2009-02-01
This study is to investigate the incremental effect of using a high performance computer-aided detection (CAD) system in detection of solitary pulmonary nodules in chest radiographs. The Kodak Chest CAD system was evaluated by a panel of six radiologists at different levels of experience. The observer study consisted of two independent phases: readings without CAD and readings with assistance of CAD. The study was conducted over a set of chest radiographs comprising 150 cancer cases and 150 cancer-free cases. The actual sensitivity of the CAD system is 72% with 3.7 false positives per case. Receiver operating characteristic (ROC) analysis was used to assess the overall observer performance. The AUZ (area under ROC curve) showed a significantly improvement (P=0.0001) from 0.844 to 0.884 after using CAD. The ROC analysis was also applied for observer performances on nodules in different sizes and visibilities. The average AUZs are improved from 0.798 to 0.835 (P=0.0003) for 5-10mm nodules, 0.853 to 0.907 (P=0.001) for 10-15mm nodules, 0.864 to 0.897 (P=0.051) for 15-20 mm nodules and 0.859 to 0.896 (P=0.0342) for 20-30mm nodules, respectively. For different visibilities, the average AUZs are improved from 0.886 to 0.915 (P=0.0337), 0.803 to 0.840 (P=0.063), 0.830 to 0.893 (P=0.0001), and 0.813 to 0.847 (P=0.152), for nodules clearly visible, hidden by ribs, partially overlap with ribs, and overlap with other structures, respectively. These results showed that observer performance could be greatly improved when the CAD system is employed as a second reader, especially for small nodules and nodules occluded by ribs.
Burns, Jane M; Webb, Marianne; Durkin, Lauren A; Hickie, Ian B
2010-06-07
Reach Out Central (ROC) is a serious game drawing on the principles of cognitive behaviour theory that has been designed to improve the mental health and wellbeing of young people, particularly men. ROC was developed over a 3-year period from 2003 to 2006, in consultation with young people aged 16-25 years who use the Reach Out mental health website http://www.reachout.com). ROC was launched online in September 2007. A traditional and viral awareness campaign was designed to engage young men, particularly "gamers". In the first month after launch, ROC had 76 045 unique website visits, with 10 542 new members (52% male) joining Reach Out. An independent online evaluation involving 266 young people aged 18-25 years was conducted between August 2007 and February 2008 to examine psychological wellbeing, stigma and help seeking in ROC players. Overall results indicated that ROC was successful in attracting, engaging and educating young people. Young women reported reduced psychological distress and improved life satisfaction, problem solving and help seeking; however, no significant changes were observed for young men. Although ROC was successful in attracting young men, demonstrating that the concept resonates with them, the service failed to keep them engaged. Further research is needed to explore how (or what changes need to be made) to sustain young men's engagement in the game.
Least squares regression methods for clustered ROC data with discrete covariates.
Tang, Liansheng Larry; Zhang, Wei; Li, Qizhai; Ye, Xuan; Chan, Leighton
2016-07-01
The receiver operating characteristic (ROC) curve is a popular tool to evaluate and compare the accuracy of diagnostic tests to distinguish the diseased group from the nondiseased group when test results from tests are continuous or ordinal. A complicated data setting occurs when multiple tests are measured on abnormal and normal locations from the same subject and the measurements are clustered within the subject. Although least squares regression methods can be used for the estimation of ROC curve from correlated data, how to develop the least squares methods to estimate the ROC curve from the clustered data has not been studied. Also, the statistical properties of the least squares methods under the clustering setting are unknown. In this article, we develop the least squares ROC methods to allow the baseline and link functions to differ, and more importantly, to accommodate clustered data with discrete covariates. The methods can generate smooth ROC curves that satisfy the inherent continuous property of the true underlying curve. The least squares methods are shown to be more efficient than the existing nonparametric ROC methods under appropriate model assumptions in simulation studies. We apply the methods to a real example in the detection of glaucomatous deterioration. We also derive the asymptotic properties of the proposed methods. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Antebi, Ben; Benov, Avi; Mann-Salinas, Elizabeth A; Le, Tuan D; Cancio, Leopoldo C; Wenke, Joseph C; Paran, Haim; Yitzhak, Avraham; Tarif, Bader; Gross, Kirby R; Dagan, David; Glassberg, Elon
2016-11-01
As new conflicts emerge and enemies evolve, military medical organizations worldwide must adopt the "lessons learned." In this study, we describe roles of care (ROCs) deployed and injuries sustained by both US and Israeli militaries during recent conflicts. The purpose of this collaborative work is facilitate exchange of medical data among allied forces in order to advance military medicine and facilitate strategic readiness for future military engagements that may involve less predictable situations of evacuation and care, such as prolonged field care. This retrospective study was conducted for the periods of 2003 to 2014 from data retrieved from the Department of Defense Trauma Registry and the Israel Defense Force (IDF) Trauma Registry. Comparative analyses included ROC capabilities, casualties who died of wounds, as well as mechanism of injury, anatomical wound distribution, and Injury Severity Score of US and IDF casualties during recent conflicts. Although concept of ROCs was similar among militaries, the IDF supports increased capabilities at point of injury and Role 1 including the presence of physicians, but with limited deployment of other ROCs; conversely, the US maintains fewer capabilities at Role 1 but utilized the entire spectrum of care, including extensive deployment of Roles 2/2+, during recent conflicts. Casualties from US forces (n = 19,005) and IDF (n = 2,637) exhibited significant differences in patterns of injury with higher proportions of casualties who died of wounds in the US forces (4%) compared with the IDF (0.6%). As these data suggest deployed ROCs and injury patterns of US and Israeli militaries were both conflict and system specific. We envision that identification of discordant factors and common medical strategies of the two militaries will enable strategic readiness for future conflicts as well as foster further collaboration among allied forces with the overarching universal goal of eliminating preventable death on the battlefield.
Self-Healing, Inflatable, Rigidizable Shelter
NASA Technical Reports Server (NTRS)
Haight, Andrea; Gosau, Jan-Michael; Dixit, Anshu; Gleeson, Dan
2012-01-01
An inflatable, rigidizable shelter system was developed based on Rigi dization on Command (ROC) technology incorporating not only the requ ired low-stowage volume and lightweight character achieved from an i nflatable/rigidizable system, but also a self-healing foam system inc orporated between the rigidizable layers of the final structure to m inimize the damage caused by any punctures to the structure.
Søreide, Kjetil; Kørner, Hartwig; Søreide, Jon Arne
2011-01-01
In surgical research, the ability to correctly classify one type of condition or specific outcome from another is of great importance for variables influencing clinical decision making. Receiver-operating characteristic (ROC) curve analysis is a useful tool in assessing the diagnostic accuracy of any variable with a continuous spectrum of results. In order to rule a disease state in or out with a given test, the test results are usually binary, with arbitrarily chosen cut-offs for defining disease versus health, or for grading of disease severity. In the postgenomic era, the translation from bench-to-bedside of biomarkers in various tissues and body fluids requires appropriate tools for analysis. In contrast to predetermining a cut-off value to define disease, the advantages of applying ROC analysis include the ability to test diagnostic accuracy across the entire range of variable scores and test outcomes. In addition, ROC analysis can easily examine visual and statistical comparisons across tests or scores. ROC is also favored because it is thought to be independent from the prevalence of the condition under investigation. ROC analysis is used in various surgical settings and across disciplines, including cancer research, biomarker assessment, imaging evaluation, and assessment of risk scores.With appropriate use, ROC curves may help identify the most appropriate cutoff value for clinical and surgical decision making and avoid confounding effects seen with subjective ratings. ROC curve results should always be put in perspective, because a good classifier does not guarantee the expected clinical outcome. In this review, we discuss the fundamental roles, suggested presentation, potential biases, and interpretation of ROC analysis in surgical research.
Tian, Guangming; Wang, Qin; Wei, Xuetuan; Ma, Xin; Chen, Shouwen
2017-04-01
Poly-γ-glutamic acid (γ-PGA), a natural biopolymer, is widely used in cosmetics, medicine, food, water treatment, and agriculture owing to its features of moisture sequestration, cation chelation, non-toxicity and biodegradability. Intracellular glutamic acid, the substrate of γ-PGA, is a limiting factor for high yield in γ-PGA production. Bacillus subtilis and Bacillus licheniformis are both important γ-PGA producing strains, and B. subtilis synthesizes glutamic acid in vivo using the unique GOGAT/GS pathway. However, little is known about the glutamate synthesis pathway in B. licheniformis. The aim of this work was to characterize the glutamate dehydrogenase (RocG) in glutamic acid synthesis from B. licheniformis with both in vivo and in vitro experiments. By re-directing the carbon flux distribution, the rocG gene deletion mutant WX-02ΔrocG produced intracellular glutamic acid with a concentration of 90ng/log(CFU), which was only 23.7% that of the wild-type WX-02 (380ng/log(CFU)). Furthermore, the γ-PGA yield of mutant WX-02ΔrocG was 5.37g/L, a decrease of 45.3% compared to the wild type (9.82g/L). In vitro enzymatic assays of RocG showed that RocG has higher affinity for 2-oxoglutarate than glutamate, and the glutamate synthesis rate was far above degradation. This is probably the first study to reveal the glutamic acid synthesis pathway and the specific functions of RocG in B. licheniformis. The results indicate that γ-PGA production can be enhanced through improving intracellular glutamic acid synthesis. Copyright © 2017 Elsevier Inc. All rights reserved.
Dong, Dong; Zhang, Lufang; Jia, Li; Ji, Wei; Wang, Zhiyong; Ren, Li; Niu, Ruifang; Zhou, Yunli
2018-06-01
Periostin (POSTN) plays an important role in numerous cancers, especially in gastrointestinal malignancy. The objective of this study was to investigate the diagnostic and prognostic role of serum POSTN in colorectal cancer (CRC). Serum periostin, together with CEA, CA19.9, CA72.4, and CA242 levels were measured in samples from 108 patients with CRC and 56 healthy controls, and their correlation with clinical characteristics was further analyzed. Receiver operating curves (ROC), Kaplan-Meier curves, and log-rank analyses were used to evaluate diagnostic and prognostic significance. Serum POSTN levels were significantly higher in patients with CRC compared with healthy controls (p < 0.0001) and associated with clinical stages (p < 0.001). ROC analysis revealed that POSTN was a biomarker comparable to CEA, CA19.9, and CA72.4 to distinguish all CRC from healthy controls (AUC = 0.75). Moreover, POSTN retained its diagnostic ability for CEA-negative (AUC = 0.69) and CA19.9-negative CRC patients (AUC = 0.71). Survival analysis revealed that patients with lower serum POSTN had longer overall survival than those with high serum POSTN (p = 0.0146). Serum POSTN might be a novel diagnostic and prognostic biomarker for patients with CRC.
The Belief Bias Effect Is Aptly Named: A Reply to Klauer and Kellen (2011)
ERIC Educational Resources Information Center
Dube, Chad; Rotello, Caren M.; Heit, Evan
2011-01-01
In "Assessing the Belief Bias Effect With ROCs: It's a Response Bias Effect," Dube, Rotello, and Heit (2010) examined the form of receiver operating characteristic (ROC) curves for reasoning and the effects of belief bias on measurement indices that differ in whether they imply a curved or linear ROC function. We concluded that the ROC…
Reliable optical card-edge (ROC) connector for avionics applications
NASA Astrophysics Data System (ADS)
Darden, Bruce V.; Pimpinella, Richard J.; Seals, John D.
1994-10-01
The Reliable Optical Card-Edge (ROC) Connector is a blind-mate backplane unit designed to meet military stress requirements for avionics applications. Its modular design represents the first significant advance in connector optics since the biconic butt-coupled connector was introduced twenty years ago. This multimode connector utilizes beam optics, micro-machined silicon, and a floating, low mass subassembly design to maintain low coupling loss under high levels of shock and vibration. The ROC connector also incorporates retracting doors to protect the unmated termini from environmental contamination and abusive handling. Design features and test results for the ROC connector are presented in this paper.
Comparison of two correlated ROC curves at a given specificity or sensitivity level.
Bantis, Leonidas E; Feng, Ziding
2016-10-30
The receiver operating characteristic (ROC) curve is the most popular statistical tool for evaluating the discriminatory capability of a given continuous biomarker. The need to compare two correlated ROC curves arises when individuals are measured with two biomarkers, which induces paired and thus correlated measurements. Many researchers have focused on comparing two correlated ROC curves in terms of the area under the curve (AUC), which summarizes the overall performance of the marker. However, particular values of specificity may be of interest. We focus on comparing two correlated ROC curves at a given specificity level. We propose parametric approaches, transformations to normality, and nonparametric kernel-based approaches. Our methods can be straightforwardly extended for inference in terms of ROC -1 (t). This is of particular interest for comparing the accuracy of two correlated biomarkers at a given sensitivity level. Extensions also involve inference for the AUC and accommodating covariates. We evaluate the robustness of our techniques through simulations, compare them with other known approaches, and present a real-data application involving prostate cancer screening. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Gardner, Andrew; Forson, Paa Kobina; Oduro, George; Stewart, Barclay; Dike, Nkechi; Glover, Paul; Maio, Ronald F
2017-01-01
The Kampala Trauma Score (KTS) has been proposed as a triage tool for use in low- and middle-income countries (LMICs). This study aimed to examine the diagnostic accuracy of KTS in predicting emergency department outcomes using timely injury estimation with Abbreviated Injury Scale (AIS) score and physician opinion to calculate KTS scores. This was a diagnostic accuracy study of KTS among injured patients presenting to Komfo Anokye Teaching Hospital A&E, Ghana. South African Triage Scale (SATS); KTS component variables, including AIS scores and physician opinion for serious injury quantification; and ED disposition were collected. Agreement between estimated AIS score and physician opinion were analyzed with normal, linear weighted, and maximum kappa. Receiver operating characteristic (ROC) analysis of KTS-AIS and KTS-physician opinion was performed to evaluate each measure's ability to predict A&E mortality and need for hospital admission to the ward or theatre. A total of 1053 patients were sampled. There was moderate agreement between AIS criteria and physician opinion by normal (κ=0.41), weighted (κ lin =0.47), and maximum (κ max =0.53) kappa. A&E mortality ROC area for KTS-AIS was 0.93, KTS-physician opinion 0.89, and SATS 0.88 with overlapping 95% confidence intervals (95%CI). Hospital admission ROC area for KTS-AIS was 0.73, KTS-physician opinion 0.79, and SATS 0.71 with statistical similarity. When evaluating only patients with serious injuries, KTS-AIS (ROC 0.88) and KTS-physician opinion (ROC 0.88) performed similarly to SATS (ROC 0.78) in predicting A&E mortality. The ROC area for KTS-AIS (ROC 0.71; 95%CI 0.66-0.75) and KTS-physician opinion (ROC 0.74; 95%CI 0.69-0.79) was significantly greater than SATS (ROC 0.57; 0.53-0.60) with regard to need for admission. KTS predicted mortality and need for admission from the ED well when early estimation of the number of serious injuries was used, regardless of method (i.e. AIS criteria or physician opinion). This study provides evidence for KTS to be used as a practical and valid triage tool to predict patient prognosis, ED outcomes and inform referral decision-making from first- or second-level hospitals in LMICs. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gardner, Andrew; Forson, Paa Kobina; Oduro, George; Stewart, Barclay; Dike, Nkechi; Glover, Paul; Maio, Ronald F.
2016-01-01
Background The Kampala Trauma Score (KTS) has been proposed as a triage tool for use in low- and middle-income countries (LMICs). This study aimed to examine the diagnostic accuracy of KTS in predicting emergency department outcomes using timely injury estimation with Abbreviated Injury Scale (AIS) score and physician opinion to calculate KTS scores. Methods This was a diagnostic accuracy study of KTS among injured patients presenting to Komfo Anokye Teaching Hospital A&E, Ghana. South African Triage Scale (SATS); KTS component variables, including AIS scores and physician opinion for serious injury quantification; and ED disposition were collected. Agreement between estimated AIS score and physician opinion were analyzed with normal, linear weighted, and maximum kappa. Receiver operating characteristic (ROC) analysis of KTS-AIS and KTS-physician opinion was performed to evaluate each measure’s ability to predict A&E mortality and need for hospital admission to the ward or theatre. Results A total of 1,053 patients were sampled. There was moderate agreement between AIS criteria and physician opinion by normal (κ=0.41), weighted (κlin=0.47), and maximum (κmax=0.53) kappa. A&E mortality ROC area for KTS-AIS was 0.93, KTS-physician opinion 0.89, and SATS 0.88 with overlapping 95% confidence intervals (95%CI). Hospital admission ROC area for KTS-AIS was 0.73, KTS-physician opinion 0.79, and SATS 0.71 with statistical similarity. When evaluating only patients with serious injuries, KTS-AIS (ROC 0.88) and KTS-physician opinion (ROC 0.88) performed similarly to SATS (ROC 0.78) in predicting A&E mortality. The ROC area for KTS-AIS (ROC 0.71; 95%CI 0.66–0.75) and KTS-physician opinion (ROC 0.74; 95%CI 0.69–0.79) was significantly greater than SATS (ROC 0.57; 0.53–0.60) with regard to need for admission. Conclusions KTS predicted mortality and need for admission from the ED well when early estimation of the number of serious injuries was used, regardless of method (i.e. AIS criteria or physician opinion). This study provides evidence for KTS to be used as a practical and valid triage tool to predict patient prognosis, ED outcomes and inform referral decision-making from first- or second-level hospitals in LMICs. PMID:27908493
2011-01-01
Introduction Due to the increasing prevalence and severity of invasive candidiasis, investigators have developed clinical prediction rules to identify patients who may benefit from antifungal prophylaxis or early empiric therapy. The aims of this study were to validate and compare the Paphitou and Ostrosky-Zeichner clinical prediction rules in ICU patients in a 689-bed academic medical center. Methods We conducted a retrospective matched case-control study from May 2003 to June 2008 to evaluate the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of each rule. Cases included adults with ICU stays of at least four days and invasive candidiasis matched to three controls by age, gender and ICU admission date. The clinical prediction rules were applied to cases and controls via retrospective chart review to evaluate the success of the rules in predicting invasive candidiasis. Paphitou's rule included diabetes, total parenteral nutrition (TPN) and dialysis with or without antibiotics. Ostrosky-Zeichner's rule included antibiotics or central venous catheter plus at least two of the following: surgery, immunosuppression, TPN, dialysis, corticosteroids and pancreatitis. Conditional logistic regression was performed to evaluate the rules. Discriminative power was evaluated by area under the receiver operating characteristic curve (AUC ROC). Results A total of 352 patients were included (88 cases and 264 controls). The incidence of invasive candidiasis among adults with an ICU stay of at least four days was 2.3%. The prediction rules performed similarly, exhibiting low PPVs (0.041 to 0.054), high NPVs (0.983 to 0.990) and AUC ROCs (0.649 to 0.705). A new prediction rule (Nebraska Medical Center rule) was developed with PPVs, NPVs and AUC ROCs of 0.047, 0.994 and 0.770, respectively. Conclusions Based on low PPVs and high NPVs, the rules are most useful for identifying patients who are not likely to develop invasive candidiasis, potentially preventing unnecessary antifungal use, optimizing patient ICU care and facilitating the design of forthcoming antifungal clinical trials. PMID:21846332
Martin-Loeches, Ignacio; Bos, Lieuwe D; Povoa, Pedro; Ramirez, Paula; Schultz, Marcus J; Torres, Antoni; Artigas, Antonio
2015-12-01
The diagnosis of ventilator-associated pneumonia (VAP) is challenging. An important aspect to improve outcome is early recognition of VAP and the initiation of the appropriate empirical treatment. We hypothesized that biological markers in plasma can rule out VAP at the moment of clinical suspicion and could rule in VAP before the diagnosis can be made clinically. In this prospective study, patients with VAP (n = 24, microbiology confirmed) were compared to controls (n = 19) with a similar duration of mechanical ventilation. Blood samples from the day of VAP diagnosis and 1 and 3 days before were analyzed with a multiplex array for markers of inflammation, coagulation, and apoptosis. The best biomarker combination was selected and the diagnostic accuracy was given by the area under the receiver operating characteristic curve (ROC-AUC). TNF-receptor 1 (TNFRI) and granulocyte colony-stimulating factor (GCSF) were selected as optimal biomarkers at the day of VAP diagnosis, which resulted in a ROC-AUC of 0.96, with excellent sensitivity. Three days before the diagnosis TNFRI and plasminogen activator inhibitor-1 (PAI-1) levels in plasma predicted VAP with a ROC-AUC of 0.79. The slope of IL-10 and PAI-1 resulted in a ROC-AUC of 0.77. These biomarkers improved the classification of the clinical pulmonary infection score when combined. Concentration of TNFRI and PAI-1 and the slope of PAI-1 and IL-10 may be used to predict the development of VAP as early as 3 days before the diagnosis made clinically. TNFRI and GCSF may be used to exclude VAP at the moment of clinical suspicion. Especially TNFRI seems to be a promising marker for the prediction and diagnosis of VAP.
Corrected ROC analysis for misclassified binary outcomes.
Zawistowski, Matthew; Sussman, Jeremy B; Hofer, Timothy P; Bentley, Douglas; Hayward, Rodney A; Wiitala, Wyndy L
2017-06-15
Creating accurate risk prediction models from Big Data resources such as Electronic Health Records (EHRs) is a critical step toward achieving precision medicine. A major challenge in developing these tools is accounting for imperfect aspects of EHR data, particularly the potential for misclassified outcomes. Misclassification, the swapping of case and control outcome labels, is well known to bias effect size estimates for regression prediction models. In this paper, we study the effect of misclassification on accuracy assessment for risk prediction models and find that it leads to bias in the area under the curve (AUC) metric from standard ROC analysis. The extent of the bias is determined by the false positive and false negative misclassification rates as well as disease prevalence. Notably, we show that simply correcting for misclassification while building the prediction model is not sufficient to remove the bias in AUC. We therefore introduce an intuitive misclassification-adjusted ROC procedure that accounts for uncertainty in observed outcomes and produces bias-corrected estimates of the true AUC. The method requires that misclassification rates are either known or can be estimated, quantities typically required for the modeling step. The computational simplicity of our method is a key advantage, making it ideal for efficiently comparing multiple prediction models on very large datasets. Finally, we apply the correction method to a hospitalization prediction model from a cohort of over 1 million patients from the Veterans Health Administrations EHR. Implementations of the ROC correction are provided for Stata and R. Published 2017. This article is a U.S. Government work and is in the public domain in the USA. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
Effect of coagulation on treatment of municipal wastewater reverse osmosis concentrate by UVC/H2O2.
Umar, Muhammad; Roddick, Felicity; Fan, Linhua
2014-02-15
Disposal of reverse osmosis concentrate (ROC) is a growing concern due to potential health and ecological risks. Alum coagulation was investigated as pre-treatment for the UVC/H2O2 treatment of two high salinity ROC samples (ROC A and B) of comparable organic and inorganic content. Coagulation removed a greater fraction of the organic content for ROC B (29%) than ROC A (16%) which correlated well with the reductions of colour and A254. Although the total reductions after 60 min UVC/H2O2 treatment with and without coagulation were comparable, large differences in the trends of reduction were observed which were attributed to the different nature of the organic content (humic-like) of the samples as indicated by the LC-OCD analyses and different initial (5% and 16%) biodegradability. Coagulation and UVC/H2O2 treatment preferentially removed humic-like compounds which resulted in low reaction rates after UVC/H2O2 treatment of the coagulated samples. The improvement in biodegradability was greater (2-3-fold) during UVC/H2O2 treatment of the pre-treated samples than without pre-treatment. The target DOC residual (≤ 15 mg/L) was obtained after 30 and 20 min irradiation of pre-treated ROC A and ROC B with downstream biological treatment, corresponding to reductions of 55% and 62%, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.
Hyperglycosylated hCG and Placenta Accreta Spectrum.
Einerson, Brett D; Straubhar, Alli; Soisson, Sean; Szczotka, Kathryn; Dodson, Mark K; Silver, Robert M; Soisson, Andrew P
2018-02-28
We aimed to evaluate the relationship between hyperglycosylated human chorionic gonadotropin (hCG-H) and placenta accreta spectrum (PAS) in the second and third trimesters of pregnancy. This was a case-control study of PAS and controls. hCG-H was measured in the second and third trimesters of pregnancy in women with pathologically confirmed cases of PAS and in gestational age-matched controls without PAS. We compared serum hCG-H levels in cases and controls, calculated summary statistics for diagnostic accuracy, and used receiver operating characteristic (ROC) curves to define an optimal cut-point for diagnosis of PAS using hCG-H. Thirty case samples and 30 control samples were evaluated for hCG-H. Mean hCG-H was lower in the case compared with control group (7.8 ± 5.9 μg/L vs. 11.8 ± 8.8 μg/L, p = 0.03). At an optimal cut-point for hCG-H of ≤7.6 μg/L, the sensitivity, specificity, positive likelihood ratios, negative likelihood ratios, and area under the ROC curve were 66.7%, 69.7%, 2.20%, 0.48%, and 0.68%, respectively. Hyperglycosylated hCG levels in the second and third trimesters of pregnancy were lower in patients with PAS than in controls, but hCG-H showed only modest capability as a diagnostic test for PAS. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Morphological and wavelet features towards sonographic thyroid nodules evaluation.
Tsantis, Stavros; Dimitropoulos, Nikos; Cavouras, Dionisis; Nikiforidis, George
2009-03-01
This paper presents a computer-based classification scheme that utilized various morphological and novel wavelet-based features towards malignancy risk evaluation of thyroid nodules in ultrasonography. The study comprised 85 ultrasound images-patients that were cytological confirmed (54 low-risk and 31 high-risk). A set of 20 features (12 based on nodules boundary shape and 8 based on wavelet local maxima located within each nodule) has been generated. Two powerful pattern recognition algorithms (support vector machines and probabilistic neural networks) have been designed and developed in order to quantify the power of differentiation of the introduced features. A comparative study has also been held, in order to estimate the impact speckle had onto the classification procedure. The diagnostic sensitivity and specificity of both classifiers was made by means of receiver operating characteristics (ROC) analysis. In the speckle-free feature set, the area under the ROC curve was 0.96 for the support vector machines classifier whereas for the probabilistic neural networks was 0.91. In the feature set with speckle, the corresponding areas under the ROC curves were 0.88 and 0.86 respectively for the two classifiers. The proposed features can increase the classification accuracy and decrease the rate of missing and misdiagnosis in thyroid cancer control.
Liu, Cheng; Wu, Wenying; Yang, Qing; Hu, Ming; Zhao, Yang; Hong, Li
2015-06-01
To investigate the correlation between pelvic organ prolapse quantitation (POP-Q) indication points and the incidence of occult stress urinary incontinence (OSUI) and its impact on prognosis. Retrospective study medical records of 93 patients with pelvic organ prolapse (POP) staged at III-IV, of which underwent pelvic reconstruction operations with Prolift system from Jan. 2007 to Sept. 2012. None of these patients had clinical manifestations of stress urinary incontinence (SUI) before surgery, and in which 44 patients were included in study group (POP complicated with OSUI) because they were identified with OSUI, another 49 patients as control group (simple POP). Follow-up and collecting datas including POP-Q, stress test, urodynamic recordings, incidence of de novo SUI, statistic analyzing by logistic regression and receiver operating characteristic curve (ROC). (1) The study group had a much higher incidence of 30% (13/44) on de novo SUI than that of control group (4%, 2/49; P < 0.01). (2) Vaginal delivery (OR = 5.327, 95% CI: 1.120-25.347), constipation (OR = 5.789, 95% CI: 1.492-22.459), preoperative OSUI (OR = 13.695, 95% CI: 2.980-62.944), anterior vaginal wall prolapse (OR = 6.115, 95% CI: 1.231-30.379) were identified as dependent risk factors for de novo SUI by logistic regression analysis. (3) For POP patients that complicated with OSUI, we chose a cutoff value of +1.5 cm for Aa point as the threshold to predicting incidence of de novo SUI according to ROC curve, area under the curve (AUC) was 0.889 (P < 0.05), the sensitivity reached 88.9% and specificity was 73.9%. According to ROC curve of Ba point, a cutoff value of +2.5 cm was chosen as the threshold to predicting incidence of de novo SUI post-operation, it had a sensitivity of 66.7% and specificity of 82.6%, AUC was 0.766 (P < 0.05). Pre-operative OSUI is a dependent risk factor of de novo SUI for advanced POP patients. Aa and Ba points are correlated with preoperative OSUI, and it is worthy to be considered as a risk predictor on forecasting the incidence of de novo SUI post pelvic reconstruction surgery.
Mahfuz, Mohammad Upal
2016-10-01
In this paper, the expressions of achievable strength-based detection probabilities of concentration-encoded molecular communication (CEMC) system have been derived based on finite pulsewidth (FP) pulse-amplitude modulated (PAM) on-off keying (OOK) modulation scheme and strength threshold. An FP-PAM system is characterized by its duty cycle α that indicates the fraction of the entire symbol duration the transmitter remains on and transmits the signal. Results show that the detection performance of an FP-PAM OOK CEMC system significantly depends on the statistical distribution parameters of diffusion-based propagation noise and intersymbol interference (ISI). Analytical detection performance of an FP-PAM OOK CEMC system under ISI scenario has been explained and compared based on receiver operating characteristics (ROC) for impulse (i.e., spike)-modulated (IM) and FP-PAM CEMC schemes. It is shown that the effects of diffusion noise and ISI on ROC can be explained separately based on their communication range-dependent statistics. With full duty cycle, an FP-PAM scheme provides significantly worse performance than an IM scheme. The paper also analyzes the performance of the system when duty cycle, transmission data rate, and quantity of molecules vary.
ERIC Educational Resources Information Center
Eckes, Thomas
2017-01-01
This paper presents an approach to standard setting that combines the prototype group method (PGM; Eckes, 2012) with a receiver operating characteristic (ROC) analysis. The combined PGM-ROC approach is applied to setting cut scores on a placement test of English as a foreign language (EFL). To implement the PGM, experts first named learners whom…
Processes and process development in Taiwan
NASA Technical Reports Server (NTRS)
Hwang, H. L.
1986-01-01
Silicon material research in the Republic of China (ROC) parallels its development in the electronic industry. A brief outline of the historical development in ROC silicon material research is given. Emphasis is placed on the recent Silane Project managed by the National Science Council, ROC, including project objectives, task forces, and recent accomplishments. An introduction is also given to industrialization of the key technologies developed in this project.
Discriminatory power of common genetic variants in personalized breast cancer diagnosis
NASA Astrophysics Data System (ADS)
Wu, Yirong; Abbey, Craig K.; Liu, Jie; Ong, Irene; Peissig, Peggy; Onitilo, Adedayo A.; Fan, Jun; Yuan, Ming; Burnside, Elizabeth S.
2016-03-01
Technology advances in genome-wide association studies (GWAS) has engendered optimism that we have entered a new age of precision medicine, in which the risk of breast cancer can be predicted on the basis of a person's genetic variants. The goal of this study is to evaluate the discriminatory power of common genetic variants in breast cancer risk estimation. We conducted a retrospective case-control study drawing from an existing personalized medicine data repository. We collected variables that predict breast cancer risk: 153 high-frequency/low-penetrance genetic variants, reflecting the state-of-the-art GWAS on breast cancer, mammography descriptors and BI-RADS assessment categories in the Breast Imaging Reporting and Data System (BI-RADS) lexicon. We trained and tested naïve Bayes models by using these predictive variables. We generated ROC curves and used the area under the ROC curve (AUC) to quantify predictive performance. We found that genetic variants achieved comparable predictive performance to BI-RADS assessment categories in terms of AUC (0.650 vs. 0.659, p-value = 0.742), but significantly lower predictive performance than the combination of BI-RADS assessment categories and mammography descriptors (0.650 vs. 0.751, p-value < 0.001). A better understanding of relative predictive capability of genetic variants and mammography data may benefit clinicians and patients to make appropriate decisions about breast cancer screening, prevention, and treatment in the era of precision medicine.
Basic concepts and development of an all-purpose computer interface for ROC/FROC observer study.
Shiraishi, Junji; Fukuoka, Daisuke; Hara, Takeshi; Abe, Hiroyuki
2013-01-01
In this study, we initially investigated various aspects of requirements for a computer interface employed in receiver operating characteristic (ROC) and free-response ROC (FROC) observer studies which involve digital images and ratings obtained by observers (radiologists). Secondly, by taking into account these aspects, an all-purpose computer interface utilized for these observer performance studies was developed. Basically, the observer studies can be classified into three paradigms, such as one rating for one case without an identification of a signal location, one rating for one case with an identification of a signal location, and multiple ratings for one case with identification of signal locations. For these paradigms, display modes on the computer interface can be used for single/multiple views of a static image, continuous viewing with cascade images (i.e., CT, MRI), and dynamic viewing of movies (i.e., DSA, ultrasound). Various functions on these display modes, which include windowing (contrast/level), magnifications, and annotations, are needed to be selected by an experimenter corresponding to the purpose of the research. In addition, the rules of judgment for distinguishing between true positives and false positives are an important factor for estimating diagnostic accuracy in an observer study. We developed a computer interface which runs on a Windows operating system by taking into account all aspects required for various observer studies. This computer interface requires experimenters to have sufficient knowledge about ROC/FROC observer studies, but allows its use for any purpose of the observer studies. This computer interface will be distributed publicly in the near future.
Quantifying Performance Bias in Label Fusion
2012-08-21
detect ), may provide the end-user with the means to appropriately adjust the performance and optimal thresholds for performance by fusing legacy systems...boolean combination of classification systems in ROC space: An application to anomaly detection with HMMs. Pattern Recognition, 43(8), 2732-2752. 10...Shamsuddin, S. (2009). An overview of neural networks use in anomaly intrusion detection systems. Paper presented at the Research and Development (SCOReD
Rational-Emotive Therapy and the Reduction of Interpersonal Anxiety in Junior High School Students.
ERIC Educational Resources Information Center
Warren, Ricks; And Others
1984-01-01
Evaluated the effectiveness of rational-emotive therapy and rational-emotive imagery in 59 junior high school students assigned to rational-emotive therapy without imagery (RET), rational-emotive therapy with imagery (REI), relationship-oriented counseling (ROC), and control (WLC) groups. The RET and REI groups were rated on sociometric measures…
Takenaka, Shin; Ventura, Walter; Sterrantino, Anna Freni; Kawashima, Akihiro; Koide, Keiko; Hori, Kyoko; Farina, Antonio; Sekizawa, Akihiko
2015-06-01
To predict the occurrence of fetal growth restriction (FGR) by analyzing messenger RNA (mRNA) expression levels of vascular endothelial growth factor receptor 1 (fms-like tyrosine kinase 1 [Flt-1]) in maternal blood. Eleven women with FGR were matched with 88 controls. Plasma samples were obtained during each trimester. The Flt-1 mRNA expression levels were compared between groups. Predicted probabilities were calculated, and sensitivity-specificity (receiver-operating characteristic [ROC]) curves were assessed based on regression models for each trimester measurement and possible combinations of measurements. The mRNA levels of the FGR group during all trimesters were significantly higher than those of the control group. The ROC curve of combined first and second trimester data yielded a detection rate of 60% at a 10% false-positive rate, with an area under curve of 0.79. The Flt-1 mRNA expression in maternal blood can be used as a marker to predict the development of FGR, long before a clinical diagnosis is made. © The Author(s) 2014.
User-friendly tools on handheld devices for observer performance study
NASA Astrophysics Data System (ADS)
Matsumoto, Takuya; Hara, Takeshi; Shiraishi, Junji; Fukuoka, Daisuke; Abe, Hiroyuki; Matsusako, Masaki; Yamada, Akira; Zhou, Xiangrong; Fujita, Hiroshi
2012-02-01
ROC studies require complex procedures to select cases from many data samples, and to set confidence levels in each selected case to generate ROC curves. In some observer performance studies, researchers have to develop software with specific graphical user interface (GUI) to obtain confidence levels from readers. Because ROC studies could be designed for various clinical situations, it is difficult task for preparing software corresponding to every ROC studies. In this work, we have developed software for recording confidence levels during observer studies on tiny personal handheld devices such as iPhone, iPod touch, and iPad. To confirm the functions of our software, three radiologists performed observer studies to detect lung nodules by using public database of chest radiograms published by Japan Society of Radiological Technology. The output in text format conformed to the format for the famous ROC kit from the University of Chicago. Times required for the reading each case was recorded very precisely.
2014-01-01
Objective To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Method Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Results Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. Conclusions This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses. PMID:23965298
Youngstrom, Eric A
2014-03-01
To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses.
NASA Astrophysics Data System (ADS)
Liu, Pengbo; Mongelli, Max; Mondry, Adrian
2004-07-01
The purpose of this study is to verify by Receiver Operating Characteristics (ROC) a mathematical model supporting the hypothesis that IUGR can be diagnosed by estimating growth velocity. The ROC compare computerized simulation results with clinical data from 325 pregnant British women. Each patient had 6 consecutive ultrasound examinations for fetal abdominal circumference (fac). Customized and un-customized fetal weights were calculated according to Hadlock"s formula. IUGR was diagnosed by the clinical standard, i.e. estimated weight below the tenth percentile. Growth velocity was estimated by calculating the changes of fac (Dzfac/dt) at various time intervals from 3 to 10 weeks. Finally, ROC was used to compare the methods. At 3~4 weeks scan interval, the area under the ROC curve is 0.68 for customized data and 0.66 for the uncustomized data with 95% confidence interval. Comparison between simulation data and real pregnancies verified that the model is clinically acceptable.
Subtil, Fabien; Rabilloud, Muriel
2015-07-01
The receiver operating characteristic curves (ROC curves) are often used to compare continuous diagnostic tests or determine the optimal threshold of a test; however, they do not consider the costs of misclassifications or the disease prevalence. The ROC graph was extended to allow for these aspects. Two new lines are added to the ROC graph: a sensitivity line and a specificity line. Their slopes depend on the disease prevalence and on the ratio of the net benefit of treating a diseased subject to the net cost of treating a nondiseased one. First, these lines help researchers determine the range of specificities within which test comparisons of partial areas under the curves is clinically relevant. Second, the ROC curve point the farthest from the specificity line is shown to be the optimal threshold in terms of expected utility. This method was applied: (1) to determine the optimal threshold of ratio specific immunoglobulin G (IgG)/total IgG for the diagnosis of congenital toxoplasmosis and (2) to select, among two markers, the most accurate for the diagnosis of left ventricular hypertrophy in hypertensive subjects. The two additional lines transform the statistically valid ROC graph into a clinically relevant tool for test selection and threshold determination. Copyright © 2015 Elsevier Inc. All rights reserved.
Shin, Teo Jeon; Noh, Gyu-Jeong; Koo, Yong-Seo; Han, Dong Woo
2014-11-01
Mentally disabled patients show different recovery profiles compared to normal patients after general anesthesia. However, the relationship of dose-recovery profiles of mentally disabled patients has never been compared to that of normal patients. Twenty patients (10 mentally disabled patients and 10 mentally intact patients) scheduled to dental surgery under general anesthesia was recruited. Sevoflurane was administered to maintain anesthesia during dental treatment. At the end of the surgery, sevoflurane was discontinued. End-tidal sevoflurane and recovery of consciousness (ROC) were recorded after sevoflurane discontinuation. The pharmacodynamic relation between the probability of ROC and end-tidal sevoflurane concentration was analyzed using NONMEM software (version VII). End-tidal sevoflurane concentration associated with 50% probability of ROC (C₅₀) and γ value were lower in the mentally disabled patients (C₅₀=0.37 vol %, γ=16.5 in mentally intact patients, C₅₀=0.19 vol %, γ=4.58 in mentally disabled patients). Mentality was a significant covariate of C₅₀ for ROC and γ value to pharmacodynamic model. A sigmoid Emanx model explains the pharmacodynamic relationship between end-tidal sevoflurane concentration and ROC. Mentally disabled patients may recover slower from anesthesia at lower sevoflurane concentration at ROC an compared to normal patients.
Saito, Takaya; Rehmsmeier, Marc
2015-01-01
Binary classifiers are routinely evaluated with performance measures such as sensitivity and specificity, and performance is frequently illustrated with Receiver Operating Characteristics (ROC) plots. Alternative measures such as positive predictive value (PPV) and the associated Precision/Recall (PRC) plots are used less frequently. Many bioinformatics studies develop and evaluate classifiers that are to be applied to strongly imbalanced datasets in which the number of negatives outweighs the number of positives significantly. While ROC plots are visually appealing and provide an overview of a classifier's performance across a wide range of specificities, one can ask whether ROC plots could be misleading when applied in imbalanced classification scenarios. We show here that the visual interpretability of ROC plots in the context of imbalanced datasets can be deceptive with respect to conclusions about the reliability of classification performance, owing to an intuitive but wrong interpretation of specificity. PRC plots, on the other hand, can provide the viewer with an accurate prediction of future classification performance due to the fact that they evaluate the fraction of true positives among positive predictions. Our findings have potential implications for the interpretation of a large number of studies that use ROC plots on imbalanced datasets.
Shin, Teo Jeon; Noh, Gyu-Jeong; Koo, Yong-Seo
2014-01-01
Purpose Mentally disabled patients show different recovery profiles compared to normal patients after general anesthesia. However, the relationship of dose-recovery profiles of mentally disabled patients has never been compared to that of normal patients. Materials and Methods Twenty patients (10 mentally disabled patients and 10 mentally intact patients) scheduled to dental surgery under general anesthesia was recruited. Sevoflurane was administered to maintain anesthesia during dental treatment. At the end of the surgery, sevoflurane was discontinued. End-tidal sevoflurane and recovery of consciousness (ROC) were recorded after sevoflurane discontinuation. The pharmacodynamic relation between the probability of ROC and end-tidal sevoflurane concentration was analyzed using NONMEM software (version VII). Results End-tidal sevoflurane concentration associated with 50% probability of ROC (C50) and γ value were lower in the mentally disabled patients (C50=0.37 vol %, γ=16.5 in mentally intact patients, C50=0.19 vol %, γ=4.58 in mentally disabled patients). Mentality was a significant covariate of C50 for ROC and γ value to pharmacodynamic model. Conclusion A sigmoid Emanx model explains the pharmacodynamic relationship between end-tidal sevoflurane concentration and ROC. Mentally disabled patients may recover slower from anesthesia at lower sevoflurane concentration at ROC an compared to normal patients. PMID:25323901
Phelix, C F; Feltus, F A
2015-01-01
Measuring biomarkers from plant tissue samples is challenging and expensive when the desire is to integrate transcriptomics, fluxomics, metabolomics, lipidomics, proteomics, physiomics and phenomics. We present a computational biology method where only the transcriptome needs to be measured and is used to derive a set of parameters for deterministic kinetic models of metabolic pathways. The technology is called Transcriptome-To-Metabolome (TTM) biosimulations, currently under commercial development, but available for non-commercial use by researchers. The simulated results on metabolites of 30 primary and secondary metabolic pathways in rice (Oryza sativa) were used as the biomarkers to predict whether the transcriptome was from a plant that had been under drought conditions. The rice transcriptomes were accessed from public archives and each individual plant was simulated. This unique quality of the TTM technology allows standard analyses on biomarker assessments, i.e. sensitivity, specificity, positive and negative predictive values, accuracy, receiver operator characteristics (ROC) curve and area under the ROC curve (AUC). Two validation methods were also used, the holdout and 10-fold cross validations. Initially 17 metabolites were identified as candidate biomarkers based on either statistical significance on binary phenotype when compared with control samples or recognition from the literature. The top three biomarkers based on AUC were gibberellic acid 12 (0.89), trehalose (0.80) and sn1-palmitate-sn2-oleic-phosphatidylglycerol (0.70). Neither heat map analyses of transcriptomes nor all 300 metabolites clustered the stressed and control groups effectively. The TTM technology allows the emergent properties of the integrated system to generate unique and useful 'Omics' information. © 2014 German Botanical Society and The Royal Botanical Society of the Netherlands.
Evaluation of MIh Scoring System in Diagnosis of Obstructive Sleep Apnea Syndrome.
Xu, Qinxing; Du, Junwei; Ling, Xiaobo; Lu, Yangfei
2017-10-02
BACKGROUND The objective of the present study was to investigate whether the analysis of magnesium (Mg), high-sensitivity C-reactive protein (hsCRP), and ischemia-modified albumin (IMA) concentrations can be used as a non-invasive and convenient method for diagnosing obstructive sleep apnea syndrome (OSAS). MATERIAL AND METHODS After polysomnography, venous blood was collected from 33 patients with OSAS and 30 control individuals. Serum levels of Mg, hsCRP, and IMA were investigated. The relationship between these factors and apnea-hypopnea index (AHI) was analyzed using the Pearson correlation coefficient. The role of the factors was determined using a receiver operating characteristic (ROC) curve and multivariate logistic regression analysis. RESULTS The levels of hsCRP and IMA were significantly higher in patients with OSAS than in control subjects, while the levels of Mg were lower (P<0.05 for all). A significant correlation was noted between serum IMA (r=0.614; P<0.001) and hsCRP (r=0.453; P<0.001) levels and the AHI. The ROC showed that serum Mg (AUC=0.74(0.62-0.85)), hsCRP (AUC=0.77(0.65-0.87)), and IMA (AUC=0.78(0.66-0.87)) levels could be used as markers to diagnose OSAS. Moreover, our new model, MIh, which is obtained by multivariate analysis, yielded an AUC value of 0.93 (0.83-0.98). Continuous positive airway pressure (CPAP) treatment reversed the changes in the serum levels of Mg, hsCRP, and IMA. CONCLUSIONS Patients with OSAS show reduced serum Mg levels and elevated serum hsCRP and IMA levels. These observed alterations can be reversed by CPAP treatment. A novel model, named MIh, may be a promising tool for OSAS diagnosis.
Validation of the modified Ranson versus Glasgow score for pancreatitis in a Singaporean population.
Tan, Yong Hui Alvin; Rafi, Shumaila; Tyebally Fang, Mirriam; Hwang, Stephen; Lim, Ee Wen; Ngu, James; Tan, Su-Ming
2017-09-01
The characteristics of patients with acute pancreatitis in multi-ethnic Singapore differ from that of the populations used in formulating the modified Ranson and Glasgow scores. The use of these scoring systems has not previously been validated in the Singaporean setting. This study aims to validate and compare the prognostic use of the modified Ranson and Glasgow scores, and to determine the superiority of one score over the other in predicting the outcome for acute pancreatitis in the Singaporean population. This is a 3-year retrospective study of patients diagnosed with acute pancreatitis at our centre. Patients with chronic pancreatitis, acute on chronic pancreatitis, iatrogenic pancreatitis, pancreatic cancer as well as those with incomplete Ranson or Glasgow scores were excluded from the study. Case notes and computer records were reviewed for local complications of pancreatitis and organ failure. Receiver operator characteristic (ROC) curves of the Ranson and Glasgow scores were plotted for the prediction of severity and mortality. Between January 2010 and December 2012, 230 cases were diagnosed with acute pancreatitis. A majority of the patients had mild pancreatitis (n = 194, 84.3%), and the overall 30-day mortality rate was 3.5% (n = 8). ROC of the Ranson and Glasgow scoring systems for mortality showed an area under curve (AUC) of 0.854 (P = 0.001) and 0.776 (P = 0.008), respectively. For severity, the AUC for the modified Ranson and Glasgow score was calculated to be 0.694 and 0.668, respectively. The ROC curves of Ranson and Glasgow scores for mortality are comparable with that published in earlier studies. In a Singaporean population, the Ranson score is more accurate in the prediction of mortality. However, both scoring systems are poor predictors for severity of acute pancreatitis. © 2015 Royal Australasian College of Surgeons.
Kuroda, Daisuke; Sawayama, Hiroshi; Kurashige, Junji; Iwatsuki, Masaaki; Eto, Tsugio; Tokunaga, Ryuma; Kitano, Yuki; Yamamura, Kensuke; Ouchi, Mayuko; Nakamura, Kenichi; Baba, Yoshifumi; Sakamoto, Yasuo; Yamashita, Yoichi; Yoshida, Naoya; Chikamoto, Akira; Baba, Hideo
2018-03-01
Controlling Nutritional Status (CONUT), as calculated from serum albumin, total cholesterol concentration, and total lymphocyte count, was previously shown to be useful for nutritional assessment. The current study investigated the potential use of CONUT as a prognostic marker in gastric cancer patients after curative resection. Preoperative CONUT was retrospectively calculated in 416 gastric cancer patients who underwent curative resection at Kumamoto University Hospital from 2005 to 2014. The patients were divided into two groups: CONUT-high (≥4) and CONUT-low (≤3), according to time-dependent receiver operating characteristic (ROC) analysis. The associations of CONUT with clinicopathological factors and survival were evaluated. CONUT-high patients were significantly older (p < 0.001) and had a lower body mass index (p = 0.019), deeper invasion (p < 0.001), higher serum carcinoembryonic antigen (p = 0.037), and higher serum carbohydrate antigen 19-9 (p = 0.007) compared with CONUT-low patients. CONUT-high patients had significantly poorer overall survival (OS) compared with CONUT-low patients according to univariate and multivariate analyses (hazard ratio: 5.09, 95% confidence interval 3.12-8.30, p < 0.001). In time-dependent ROC analysis, CONUT had a higher area under the ROC curve (AUC) for the prediction of 5-year OS than the neutrophil lymphocyte ratio, the Modified Glasgow Prognostic Score, or pStage. When the time-dependent AUC curve was used to predict OS, CONUT tended to maintain its predictive accuracy for long-term survival at a significantly higher level for an extended period after surgery when compared with the other markers tested. CONUT is useful for not only estimating nutritional status but also for predicting long-term OS in gastric cancer patients after curative resection.
Chen, Liangyou; Reisner, Andrew T; Gribok, Andrei; Reifman, Jaques
2010-11-01
It has been widely accepted that metrics related to respiration-induced waveform variation (RIWV) of the photoplethysmogram (PPG) have been associated with hypovolemia in mechanically ventilated patients and in controlled laboratory environments. In this retrospective study, we investigated if PPG RIWV metrics have diagnostic value for patients with acute hemorrhagic hypovolemia in the prehospital environment. Photoplethysmogram waveforms and basic vital signs were recorded in trauma patients during prehospital transport. Retrospectively, we used automated algorithms to select patient records with all five basic vital signs and 45 s or longer continuous, clean PPG segments. From these segments, we identified the onset and peak of individual heartbeats and computed waveform variations in the beats' peaks and amplitudes: (1) as the range between the maximum and the minimum (max-min) values and (2) as their interquartile range (IQR). We evaluated their receiver operating characteristic (ROC) curves for major hemorrhage. Separately, we tested whether RIWV metrics have potential independent information beyond basic vital signs by applying multivariate regression. In 344 patients, RIWV max-min yielded areas under the ROC curves (AUCs) not significantly better than a random AUC of 0.50. Respiration-induced waveform variation computed as IQR yielded ROC AUCs of 0.65 (95% confidence interval, 0.54-0.76) and of 0.64 (0.51-0.75), for peak and amplitude measures, respectively. The IQR metrics added independent information to basic vital signs (P < 0.05), but only moderately improved the overall AUC. Photoplethysmogram RIWV measured as IQR is preferable over max-min, and using PPG RIWV may enhance physiologic monitoring of spontaneously breathing patients outside strictly controlled laboratory environments.
Aktürk, Semra; Büyükavcı, Raikan
2017-08-01
Fibromyalgia syndrome (FMS) is characterized by chronic widespread pain and systemic symptoms. The aetiology and pathogenesis of fibromyalgia are not yet fully understood. Blood neutrophil/lymphocyte ratio (NLR) is a marker of systemic inflammatory response. Platelet distribution width (PDW) and mean platelet volume (MPV) are the determinants of platelet activation and studied as markers in inflammatory diseases. The aim of the present study was to evaluate levels of NLR,PDW and MPV in patients with fibromyalgia. A total of 197 FMS patients and 53 healthy controls are included in the study. Demographic characteristics, erythrocyte sedimentation rate, C-reactive protein, neutrophil, lymphocyte and platelet counts, platelet distribution width and mean platelet volume levels were recorded. In the patient group, the blood NLR and MPV were significantly higher and the PDW was significantly lower compared to the control group. In the roc curve analysis, blood PDW ≥had 90.4% sensitivity and 90% specificity in predicting fibromyalgia. The results of this study suggest NLR and PDW as promising inflammatory markers indicating fibromyalgia and may be beneficial in facilitating the diagnosis of FMS patients.
Drain the lysosome: Development of the novel orally available autophagy inhibitor ROC-325.
Carew, Jennifer S; Nawrocki, Steffan T
2017-04-03
Although macroautophagy/autophagy is a key contributor to malignant pathogenesis and therapeutic resistance, there are few FDA-approved agents that significantly affect this pathway. We used medicinal chemistry strategies to develop ROC-325, an orally available novel inhibitor of lysosomal-mediated autophagy. Detailed in vitro and in vivo studies in preclinical models of renal cell carcinoma demonstrated that ROC-325 triggered the hallmark features of lysosomal autophagy inhibition, was very well tolerated, and exhibited significant superiority with respect to autophagy inhibition and anticancer activity over hydroxychloroquine. Our findings support the clinical investigation of the safety and preliminary efficacy of ROC-325 in patients with autophagy-dependent malignancies and other disorders where aberrant autophagy contributes to disease pathogenesis.
Issues in assessing multi-institutional performance of BI-RADS-based CAD systems
NASA Astrophysics Data System (ADS)
Markey, Mia K.; Lo, Joseph Y.
2005-04-01
The purpose of this study was to investigate factors that impact the generalization of breast cancer computer-aided diagnosis (CAD) systems that utilize the Breast Imaging Reporting and Data System (BI-RADS). Data sets from four institutions were analyzed: Duke University Medical Center, University of Pennsylvania Medical Center, Massachusetts General Hospital, and Wake Forest University. The latter two data sets are subsets of the Digital Database for Screening Mammography. Each data set consisted of descriptions of mammographic lesions according to the BI-RADS lexicon, patient age, and pathology status (benign/malignant). Models were developed to predict pathology status from the BI-RADS descriptors and the patient age. Comparisons between the models built on data from the different institutions were made in terms of empirical (non-parametric) receiver operating characteristic (ROC) curves. Results suggest that BI-RADS-based CAD systems focused on specific classes of lesions may be more generally applicable than models that cover several lesion types. However, better generalization was seen in terms of the area under the ROC curve than in the partial area index (>90% sensitivity). Previous studies have illustrated the challenges in translating a BI-RADS-based CAD system from one institution to another. This study provides new insights into possible approaches to improve the generalization of BI-RADS-based CAD systems.
ERIC Educational Resources Information Center
Kuo, Mike Chu-Hsun
A study investigated the current enterprise training system in Taiwan and proposed suitable training suggestions for manufacturing industry through a carefully designed case study. Literature review and field study were used to gather research data. Interviews were conducted at four large manufacturing companies during the period October 1990 to…
Chai, Rifai; Naik, Ganesh R; Nguyen, Tuan Nghia; Ling, Sai Ho; Tran, Yvonne; Craig, Ashley; Nguyen, Hung T
2017-05-01
This paper presents a two-class electroencephal-ography-based classification for classifying of driver fatigue (fatigue state versus alert state) from 43 healthy participants. The system uses independent component by entropy rate bound minimization analysis (ERBM-ICA) for the source separation, autoregressive (AR) modeling for the features extraction, and Bayesian neural network for the classification algorithm. The classification results demonstrate a sensitivity of 89.7%, a specificity of 86.8%, and an accuracy of 88.2%. The combination of ERBM-ICA (source separator), AR (feature extractor), and Bayesian neural network (classifier) provides the best outcome with a p-value < 0.05 with the highest value of area under the receiver operating curve (AUC-ROC = 0.93) against other methods such as power spectral density as feature extractor (AUC-ROC = 0.81). The results of this study suggest the method could be utilized effectively for a countermeasure device for driver fatigue identification and other adverse event applications.
Remote CT reading using an ultramobile PC and web-based remote viewing over a wireless network.
Choi, Hyuk Joong; Lee, Jeong Hun; Kang, Bo Seung
2012-01-01
We developed a new type of mobile teleradiology system using an ultramobile PC (UMPC) for web-based remote viewing over a wireless network. We assessed the diagnostic performance of this system for abdominal CT interpretation. Performance was compared with an emergency department clinical monitor using a DICOM viewer. A total of 100 abdominal CT examinations were presented to four observers. There were 56 examinations showing appendicitis and 44 which were normal. The observers viewed the images using a UMPC display and an LCD monitor and rated each examination on a five-point scale. Receiver operating characteristics (ROC) analysis was used to test for differences. The sensitivity and specificities of all observers were similarly high. The average area under the ROC curve for readings performed on the UMPC and the LCD monitor was 0.959 and 0.976, respectively. There were no significant differences between the two display systems for interpreting abdominal CTs. The web-based mobile teleradiology system appears to be feasible for reading abdominal CTs for diagnosing appendicitis and may be valuable in emergency teleconsultation. Copyright © 2012 by the Royal Society of Medicine Press Ltd
Peng, Hong-Xin; Yang, Lin; He, Bang-Shun; Pan, Yu-Qin; Ying, Hou-Qun; Sun, Hui-Ling; Lin, Kang; Hu, Xiu-Xiu; Xu, Tao; Wang, Shu-Kui
2017-09-01
Inflammation plays an important role in the development and progression of CRC. The members of inflammatory biomarkers, preoperative NLR and PLR, have been proved by numerous studies to be promising prognostic biomarkers for CRC. However, the diagnostic value of the two biomarkers in CRC remains unknown, and no study reported the combined diagnostic efficacy of NLR, PLR and CEA. Five hundred and fifty-nine patients with I-III stage CRC undergoing surgical resection and 559 gender- and age-matched healthy controls were enrolled in this retrospective study. NLR and PLR were calculated from preoperative peripheral blood cell count detected using white blood cell five classification by Sysmex XT-1800i Automated Hematology System and serum CEA were measured by electrochemiluminescence by ELECSYS 2010. The diagnostic performance of NLR, PLR and CEA for CRC was evaluated by ROC curve. Levels of NLR and PLR in the cases were significantly higher than them in the healthy controls. ROC curves comparison analyses showed that the diagnostic efficacy of NLR (AUC=.755, 95%CI=.728-.780) alone for CRC was significantly higher than PLR (AUC=.723, 95%CI=.696-.749, P=.037) and CEA (AUC=.690, 95%CI=.662-.717, P=.002) alone. In addition, the diagnostic efficacy of the combination of NLR, PLR and CEA(AUC=.831, 95%CI=.807-.852)for CRC was not only significantly higher than NLR alone but also higher than any combinations of the two of these three biomarkers (P<.05). Moreover, the NLR and PLR in the patients with TNM stage I/II was higher than that in the healthy controls, and patients with stage III had a higher NLR and PLR than those with stage I/II, but no significant difference was observed. Our study indicated that preoperative NLR could be a CRC diagnostic biomarker, even for early stage CRC, and the combination of NLR, PLR and CEA could significantly improve the diagnostic efficacy. © 2016 Wiley Periodicals, Inc.
Tank atmosphere perturbation: a procedure for assessing flashing losses from oil storage tanks.
Littlejohn, David; Lucas, Donald
2003-03-01
A new procedure to measure the total volume of emissions from heavy crude oil storage tanks is described. Tank flashing losses, which are difficult to measure, can be determined by correcting this value for working and breathing losses. The procedure uses a fan or blower to vent the headspace of the storage tank, with subsequent monitoring of the change in concentrations of oxygen or other gases. Combined with a separate determination of the reactive organic carbon (ROC) fraction in the gas, this method allows the evaluation of the total amount of ROC emitted. The operation of the system is described, and results from measurement of several storage tanks in California oil fields are presented. Our measurements are compared with those obtained using the California Air Resources Board (CARB) 150 method.
Ying Ouyang; Johnny M. Grace; Wayne C. Zipperer; Jeff Hatten; Janet Dewey
2018-01-01
Loads of naturally occurring total organic carbons (TOC), refractory organic carbon (ROC), and labile organic carbon (LOC) instreams control the availability of nutrients and the solubility and toxicity of contaminants and affect biological activities throughabsorption of light and complex metals with production of carcinogenic compounds....
Kawase, Setsuko; Naganawa, Shinji; Sone, Michihiko; Ikeda, Mitsuru; Ishigaki, Takeo
2006-06-01
The appropriate cutoff Hounsfield unit (HU) value for the diagnosis of otosclerosis was determined and the correlation between the bone conduction threshold and the findings of computed tomography (CT) densitometry investigated. CT images, 0.5-mm thick, were evaluated in 24 ears with otosclerosis and 19 control ears. Eight regions of interest were set around the otic capsule. The mean HU values in the area anterior to the oval window (A-OW) and anterior to the internal auditory canal (A-IAC) were significantly lower in otosclerosis than in controls. Based on receiver operating characteristic (ROC) analysis, the cutoff HU value in A-OW was determined to be 2,187.3 HU. The mean HU value in retrofenestral otosclerosis was significantly lower in the area A-OW, A-IAC and around the cochlea than in controls. Based on ROC analysis, the cutoff HU value in the latter was determined to be 2,045 HU. A statistically significant correlation was found between the density of the area A-OW and the hearing level at 500 and 1,000 Hz, and between the density of the area around the cochlea and the hearing level at most frequencies. These results suggest the semi-automated diagnosis of otosclerosis may be possible.
Diagnostic implication of fibrin degradation products and D-dimer in aortic dissection
NASA Astrophysics Data System (ADS)
Dong, Jian; Duan, Xianli; Feng, Rui; Zhao, Zhiqing; Feng, Xiang; Lu, Qingsheng; Jing, Qing; Zhou, Jian; Bao, Junmin; Jing, Zaiping
2017-03-01
Fibrin degradation products (FDP) and D-dimer have been considered to be involved in many vascular diseases. In this study we aimed to explore the diagnostic implication of FDP and D-dimer in aortic dissection patients. 202 aortic dissection patients were collected as the case group, 150 patients with other cardiovascular diseases, including myocardial infarction (MI, n = 45), pulmonary infarction (n = 51) and abdominal aortic aneurysm (n = 54) were collected as non-dissection group, and 27 healthy people were in the blank control group. The FDP and D-dimer levels were detected with immune nephelometry. Logist regression analysis was performed to evaluate the influence of FDP and D-dimer for the aortic dissection patients. ROC curve was used to determine the diagnostic value of FDP and D-dimer. The FDP and D-dimer levels were significantly higher in aortic dissection patients than in non-dissection patients and the healthy controls. FDP and D-dimer were both the risk factors for patients with aortic dissection. From the ROC analysis, diagnostic value of FDP and D-dimer were not high to distinguish aortic dissection patients from the non-dissection patients. However FDP and D-dimer could be valuable diagnostic marker to differentiate aortic dissection patients and healthy controls with both AUC 0.863.
Wilson, Georgina; Terpening, Zoe; Wong, Keith; Grunstein, Ron; Norrie, Louisa; Lewis, Simon J. G.; Naismith, Sharon L.
2014-01-01
Purpose. Mild cognitive impairment (MCI) is considered an “at risk” state for dementia and efforts are needed to target modifiable risk factors, of which Obstructive sleep apnoea (OSA) is one. This study aims to evaluate the predictive utility of the multivariate apnoea prediction index (MAPI), a patient self-report survey, to assess OSA in MCI. Methods. Thirty-seven participants with MCI and 37 age-matched controls completed the MAPI and underwent polysomnography (PSG). Correlations were used to compare the MAPI and PSG measures including oxygen desaturation index and apnoea-hypopnoea index (AHI). Receiver-operating characteristics (ROC) curve analyses were performed using various cut-off scores for apnoea severity. Results. In controls, there was a significant moderate correlation between higher MAPI scores and more severe apnoea (AHI: r = 0.47, P = 0.017). However, this relationship was not significant in the MCI sample. ROC curve analysis indicated much lower area under the curve (AUC) in the MCI sample compared to the controls across all AHI severity cut-off scores. Conclusions. In older people, the MAPI moderately correlates with AHI severity but only in those who are cognitively intact. Development of further screening tools is required in order to accurately screen for OSA in MCI. PMID:24551457
ROC-ing along: Evaluation and interpretation of receiver operating characteristic curves.
Carter, Jane V; Pan, Jianmin; Rai, Shesh N; Galandiuk, Susan
2016-06-01
It is vital for clinicians to understand and interpret correctly medical statistics as used in clinical studies. In this review, we address current issues and focus on delivering a simple, yet comprehensive, explanation of common research methodology involving receiver operating characteristic (ROC) curves. ROC curves are used most commonly in medicine as a means of evaluating diagnostic tests. Sample data from a plasma test for the diagnosis of colorectal cancer were used to generate a prediction model. These are actual, unpublished data that have been used to describe the calculation of sensitivity, specificity, positive predictive and negative predictive values, and accuracy. The ROC curves were generated to determine the accuracy of this plasma test. These curves are generated by plotting the sensitivity (true-positive rate) on the y axis and 1 - specificity (false-positive rate) on the x axis. Curves that approach closest to the coordinate (x = 0, y = 1) are more highly predictive, whereas ROC curves that lie close to the line of equality indicate that the result is no better than that obtained by chance. The optimum sensitivity and specificity can be determined from the graph as the point where the minimum distance line crosses the ROC curve. This point corresponds to the Youden index (J), a function of sensitivity and specificity used commonly to rate diagnostic tests. The area under the curve is used to quantify the overall ability of a test to discriminate between 2 outcomes. By following these simple guidelines, interpretation of ROC curves will be less difficult and they can then be interpreted more reliably when writing, reviewing, or analyzing scientific papers. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kallergi, Maria; Menychtas, Dimitrios; Georgakopoulos, Alexandros; Pianou, Nikoletta; Metaxas, Marinos; Chatziioannou, Sofia
2013-03-01
The purpose of this study was to determine whether image characteristics could be used to predict the outcome of ROC studies in PET/CT imaging. Patients suspected for recurrent thyroid cancer underwent a standard whole body (WB) examination and an additional high-resolution head-and-neck (HN) F18-FDG PET/CT scan. The value of the latter was determined with an ROC study, the results of which showed that the WB+HN combination was better than WB alone for thyroid cancer detection and diagnosis. Following the ROC experiment, the WB and HN images of confirmed benign or malignant thyroid disease were analyzed and first and second order textural features were determined. Features included minimum, mean, and maximum intensity, as well as contrast in regions of interest encircling the thyroid lesions. Lesion size and standard uptake values (SUV) were also determined. Bivariate analysis was applied to determine relationships between WB and HN features and between observer ROC responses and the various feature values. The two sets showed significant associations in the values of SUV, contrast, and lesion size. They were completely different when the intensities were considered; no relationship was found between the WB minimum, maximum, and mean ROI values and their HN counterparts. SUV and contrast were the strongest predictors of ROC performance on PET/CT examinations of thyroid cancer. The high resolution HN images seem to enhance these relationships but without a single dramatic effect as was projected from the ROC results. A combination of features from both WB and HN datasets may possibly be a more robust predictor of ROC performance.
Vidotti, Vanessa G; Costa, Vital P; Silva, Fabrício R; Resende, Graziela M; Cremasco, Fernanda; Dias, Marcelo; Gomi, Edson S
2012-06-15
Purpose. To investigate the sensitivity and specificity of machine learning classifiers (MLC) and spectral domain optical coherence tomography (SD-OCT) for the diagnosis of glaucoma. Methods. Sixty-two patients with early to moderate glaucomatous visual field damage and 48 healthy individuals were included. All subjects underwent a complete ophthalmologic examination, achromatic standard automated perimetry, and RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, California, USA). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters. Subsequently, the following MLCs were tested: Classification Tree (CTREE), Random Forest (RAN), Bagging (BAG), AdaBoost M1 (ADA), Ensemble Selection (ENS), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Naive-Bayes (NB), and Support Vector Machine (SVM). Areas under the ROC curves (aROCs) obtained for each parameter and each MLC were compared. Results. The mean age was 57.0±9.2 years for healthy individuals and 59.9±9.0 years for glaucoma patients (p=0.103). Mean deviation values were -4.1±2.4 dB for glaucoma patients and -1.5±1.6 dB for healthy individuals (p<0.001). The SD-OCT parameters with the greater aROCs were inferior quadrant (0.813), average thickness (0.807), 7 o'clock position (0.765), and 6 o'clock position (0.754). The aROCs from classifiers varied from 0.785 (ADA) to 0.818 (BAG). The aROC obtained with BAG was not significantly different from the aROC obtained with the best single SD-OCT parameter (p=0.93). Conclusions. The SD-OCT showed good diagnostic accuracy in a group of patients with early glaucoma. In this series, MLCs did not improve the sensitivity and specificity of SD-OCT for the diagnosis of glaucoma.
Meta-analysis of Diagnostic Accuracy and ROC Curves with Covariate Adjusted Semiparametric Mixtures.
Doebler, Philipp; Holling, Heinz
2015-12-01
Many screening tests dichotomize a measurement to classify subjects. Typically a cut-off value is chosen in a way that allows identification of an acceptable number of cases relative to a reference procedure, but does not produce too many false positives at the same time. Thus for the same sample many pairs of sensitivities and false positive rates result as the cut-off is varied. The curve of these points is called the receiver operating characteristic (ROC) curve. One goal of diagnostic meta-analysis is to integrate ROC curves and arrive at a summary ROC (SROC) curve. Holling, Böhning, and Böhning (Psychometrika 77:106-126, 2012a) demonstrated that finite semiparametric mixtures can describe the heterogeneity in a sample of Lehmann ROC curves well; this approach leads to clusters of SROC curves of a particular shape. We extend this work with the help of the [Formula: see text] transformation, a flexible family of transformations for proportions. A collection of SROC curves is constructed that approximately contains the Lehmann family but in addition allows the modeling of shapes beyond the Lehmann ROC curves. We introduce two rationales for determining the shape from the data. Using the fact that each curve corresponds to a natural univariate measure of diagnostic accuracy, we show how covariate adjusted mixtures lead to a meta-regression on SROC curves. Three worked examples illustrate the method.
Quantitative evaluation of the memory bias effect in ROC studies with PET/CT
NASA Astrophysics Data System (ADS)
Kallergi, Maria; Pianou, Nicoletta; Georgakopoulos, Alexandros; Kafiri, Georgia; Pavlou, Spiros; Chatziioannou, Sofia
2012-02-01
PURPOSE. The purpose of the study was to evaluate the memory bias effect in ROC experiments with tomographic data and, specifically, in the evaluation of two different PET/CT protocols for the detection and diagnosis of recurrent thyroid cancer. MATERIALS AND METHODS. Two readers participated in an ROC experiment that evaluated tomographic images from 43 patients followed up for thyroid cancer recurrence. Readers evaluated first whole body PET/CT scans of the patients and then a combination of whole body and high-resolution head and neck scans of the same patients. The second set was read twice. Once within 48 hours of the first set and the second time at least a month later. The detection and diagnostic performances of the readers in the three reading sessions were assessed with the DBMMRMC and LABMRMC software using the area under the ROC curve as a performance index. Performances were also evaluated by comparing the number and the size of the detected abnormal foci among the three readings. RESULTS. There was no performance difference between first and second treatments. There were statistically significant differences between first and third, and second and third treatments showing that memory can seriously affect the outcome of ROC studies. CONCLUSION. Despite the fact that tomographic data involve numerous image slices per patient, the memory bias effect is present and substantial and should be carefully eliminated from analogous ROC experiments.
Ratzinger, Franz; Haslacher, Helmuth; Perkmann, Thomas; Schmetterer, Klaus G; Poeppl, Wolfgang; Mitteregger, Dieter; Dorffner, Georg; Burgmann, Heinz
2015-08-01
Neutropaenic patients are at a high risk of contracting severe infections. In particular, in these patients, parameters with a high negative predictive value are desirable for excluding infection or bacteraemia. This study evaluated sepsis biomarkers in neutropaenic patients suffering from systemic inflammatory response syndrome (SIRS). Further, the predictive capacities of evaluated biomarkers in neutropaenic SIRS patients were compared to non-neutropaenic SIRS patients. In this prospective observational cohort study, patients with clinically suspected sepsis were screened. The predictive capacities of procalcitonin (PCT), C-reactive protein and lipopolysaccharide-binding protein (LBP) in neutropaenic SIRS patients were evaluated in terms of their potential to identify infection or bacteraemia and were compared to results for non-neutropaenic SIRS patients. To select an appropriate control cohort, propensity score matching was applied, balancing confounding factors between neutropaenic and non-neutropaenic SIRS patients. Of 3370 prospectively screened patients with suspected infection, 51 patients suffered from neutropaenic SIRS. For the identification of infection, none of the assessed biomarkers presented a clinically relevant discriminatory potency. Lipopolysaccharide-binding protein and PCT demonstrated discriminatory capacity to discriminate between nonbacteraemic and bacteraemic SIRS in patients with neutropaenia [receiver-operating characteristics-area under the curves (ROC-AUCs): 0.860, 0.818]. In neutropaenic SIRS patients, LBP had a significantly better ROC-AUC than in a comparable non-neutropaenic patient cohort for identifying bacteraemia (P = 0.01). In neutropaenic SIRS patients, none of the evaluated biomarkers was able to adequately identify infection. LBP and PCT presented a good performance in identifying bacteraemia. Therefore, these markers could be used for screening purposes to increase the pretest probability of blood culture analysis. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.
Ferrari, Anna; Baraldi, Carlo; Licata, Manuela; Vandelli, Daniele; Marchesi, Filippo; Palazzoli, Federica; Verri, Patrizia; Rustichelli, Cecilia; Giuliani, Enrico; Silingardi, Enrico
2016-09-01
The aim of this study is to evaluate the detection rate of almotriptan, eletriptan, frovatriptan, sumatriptan, rizatriptan, and zolmitriptan in the hair of migraineurs taking these drugs; the degree of agreement between type of self-reported triptan and triptan found in hair; if the concentrations in hair were related to the reported cumulative doses of triptans; and whether hair analysis was able to distinguish occasional use from the overuse of these drugs. Out of 300 headache patients consecutively enrolled, we included 147 migraine patients who reported to have taken at least one dose of one triptan in the previous 3 months; 51 % of the patients overused triptans. A detailed pharmacological history and a sample of hair were collected for each patient. Hair samples were analyzed by liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) by a method that we developed. All the triptans could be detected in the hair of the patients. The agreement between type of self-reported triptan and type of triptan found in hair was from fair to good for frovatriptan and zolmitriptan and excellent for almotriptan, eletriptan, sumatriptan, and rizatriptan (P < 0.01, Cohen's kappa). The correlation between the reported quantities of triptan and hair concentrations was statistically significant for almotriptan, eletriptan, rizatriptan, and sumatriptan (P < 0.01, Spearman's rank correlation coefficient). The accuracy of hair analysis in distinguishing occasionally users from overusers was high for almotriptan (ROC AUC = 0.9092), eletriptan (ROC AUC = 0.8721), rizatriptan (ROC AUC = 0.9724), and sumatriptan (ROC AUC = 0.9583). Hair analysis can be a valuable system to discriminate occasional use from triptan overuse.
Comparison of two correlated ROC curves at a given specificity or sensitivity level
Bantis, Leonidas E.; Feng, Ziding
2017-01-01
The receiver operating characteristic (ROC) curve is the most popular statistical tool for evaluating the discriminatory capability of a given continuous biomarker. The need to compare two correlated ROC curves arises when individuals are measured with two biomarkers, which induces paired and thus correlated measurements. Many researchers have focused on comparing two correlated ROC curves in terms of the area under the curve (AUC), which summarizes the overall performance of the marker. However, particular values of specificity may be of interest. We focus on comparing two correlated ROC curves at a given specificity level. We propose parametric approaches, transformations to normality, and nonparametric kernel-based approaches. Our methods can be straightforwardly extended for inference in terms of ROC−1(t). This is of particular interest for comparing the accuracy of two correlated biomarkers at a given sensitivity level. Extensions also involve inference for the AUC and accommodating covariates. We evaluate the robustness of our techniques through simulations, compare to other known approaches and present a real data application involving prostate cancer screening. PMID:27324068
An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.
Obuchowski, Nancy A
2006-02-15
ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.
The anticancer phytochemical rocaglamide inhibits Rho GTPase activity and cancer cell migration
Becker, Michael S.; Müller, Paul M.; Bajorat, Jörg; Schroeder, Anne; Giaisi, Marco; Amin, Ehsan; Ahmadian, Mohammad R.; Rocks, Oliver; Köhler, Rebecca; Krammer, Peter H.; Li-Weber, Min
2016-01-01
Chemotherapy is one of the pillars of anti-cancer therapy. Although chemotherapeutics cause regression of the primary tumor, many chemotherapeutics are often shown to induce or accelerate metastasis formation. Moreover, metastatic tumors are largely resistant against chemotherapy. As more than 90% of cancer patients die due to metastases and not due to primary tumor formation, novel drugs are needed to overcome these shortcomings. In this study, we identified the anticancer phytochemical Rocaglamide (Roc-A) to be an inhibitor of cancer cell migration, a crucial event in metastasis formation. We show that Roc-A inhibits cellular migration and invasion independently of its anti-proliferative and cytotoxic effects in different types of human cancer cells. Mechanistically, Roc-A treatment induces F-actin-based morphological changes in membrane protrusions. Further investigation of the molecular mechanisms revealed that Roc-A inhibits the activities of the small GTPases RhoA, Rac1 and Cdc42, the master regulators of cellular migration. Taken together, our results provide evidence that Roc-A may be a lead candidate for a new class of anticancer drugs that inhibit metastasis formation. PMID:27340868
He, Tianyi; Wang, Chuan; Zuo, Anju; Liu, Pan; Li, Wenjuan
2017-01-01
Aims. This study aimed to assess whether the electrochemical skin conductance (ESC) could be used to screen for diabetic cardiac autonomic neuropathy (DCAN) in a Chinese population with diabetes. Methods. We recruited 75 patients with type 2 diabetes mellitus (T2DM) and 45 controls without diabetes. DCAN was diagnosed by the cardiovascular autonomic reflex tests (CARTs) as gold standard. In all subjects ESCs of hands and feet were also detected by SUDOSCAN™ as a new screening method. The efficacy was assessed by receiver operating characteristic (ROC) curve analysis. Results. The ESCs of both hands and feet were significantly lower in T2DM patients with DCAN than those without DCAN (67.33 ± 15.37 versus 78.03 ± 13.73, P = 0.002, and 57.77 ± 20.99 versus 75.03 ± 11.41, P < 0.001). The ROC curve analysis showed the areas under the ROC curve were both 0.75 for ESCs of hands and feet in screening DCAN. And the optimal cut-off values of ESCs, sensitivities, and specificities were 76 μS, 76.7%, and 75.6% for hands and 75 μS, 80.0%, and 60.0% for feet, respectively. Conclusions. ESC measurement is a reliable and feasible method to screen DCAN in the Chinese population with diabetes before further diagnosis with CARTs. PMID:28280746
Macías García, B; González Fernández, L; Ortega Ferrusola, C; Morillo Rodríguez, A; Gallardo Bolaños, J M; Rodríguez Martinez, H; Tapia, J A; Morcuende, D; Peña, F J
2011-03-15
Fatty acids and plasmalogens were extracted from the phospholipids of the plasma membrane of stallion spermatozoa, to determine their relation with sperm quality after freezing and thawing. Sperm quality was rated using a quality index that combined the results of the analysis of sperm motility and velocity (CASA analysis), membrane status and mitochondrial membrane potential (flow cytometry) post thaw. Receiving operating system (ROC) curves were used to evaluate the value of specific lipid components of the sperm membrane herein studied as forecast of potential freezeability. From all parameters studied the ratio of percentage of C16 plasmalogens related to total phospholipids was the one with the better diagnostic value. For potentially bad freezers, the significant area under the ROC-curve was 0.74, with 75% sensitivity and 79.9% specificity for a cut off value of 26.9. Also the percentage of plasmalogens respect to total phospholipids gave good diagnostic value for bad freezers. On the other hand, the percentage of C18 fatty aldehydes related to total phospholipids of the sperm membrane properly forecasted freezeability with an area under the ROC curve of 0.70 with 70% sensitivity and 62.5% specificity for a cut off value of 0.32. Copyright © 2011 Elsevier Inc. All rights reserved.
Star Tracker Performance Estimate with IMU
NASA Technical Reports Server (NTRS)
Aretskin-Hariton, Eliot D.; Swank, Aaron J.
2015-01-01
A software tool for estimating cross-boresight error of a star tracker combined with an inertial measurement unit (IMU) was developed to support trade studies for the Integrated Radio and Optical Communication project (iROC) at the National Aeronautics and Space Administration Glenn Research Center. Typical laser communication systems, such as the Lunar Laser Communication Demonstration (LLCD) and the Laser Communication Relay Demonstration (LCRD), use a beacon to locate ground stations. iROC is investigating the use of beaconless precision laser pointing to enable laser communication at Mars orbits and beyond. Precision attitude knowledge is essential to the iROC mission to enable high-speed steering of the optical link. The preliminary concept to achieve this precision attitude knowledge is to use star trackers combined with an IMU. The Star Tracker Accuracy (STAcc) software was developed to rapidly assess the capabilities of star tracker and IMU configurations. STAcc determines the overall cross-boresight error of a star tracker with an IMU given the characteristic parameters: quantum efficiency, aperture, apparent star magnitude, exposure time, field of view, photon spread, detector pixels, spacecraft slew rate, maximum stars used for quaternion estimation, and IMU angular random walk. This paper discusses the supporting theory used to construct STAcc, verification of the program and sample results.
Efficient cost-sensitive human-machine collaboration for offline signature verification
NASA Astrophysics Data System (ADS)
Coetzer, Johannes; Swanepoel, Jacques; Sabourin, Robert
2012-01-01
We propose a novel strategy for the optimal combination of human and machine decisions in a cost-sensitive environment. The proposed algorithm should be especially beneficial to financial institutions where off-line signatures, each associated with a specific transaction value, require authentication. When presented with a collection of genuine and fraudulent training signatures, produced by so-called guinea pig writers, the proficiency of a workforce of human employees and a score-generating machine can be estimated and represented in receiver operating characteristic (ROC) space. Using a set of Boolean fusion functions, the majority vote decision of the human workforce is combined with each threshold-specific machine-generated decision. The performance of the candidate ensembles is estimated and represented in ROC space, after which only the optimal ensembles and associated decision trees are retained. When presented with a questioned signature linked to an arbitrary writer, the system first uses the ROC-based cost gradient associated with the transaction value to select the ensemble that minimises the expected cost, and then uses the corresponding decision tree to authenticate the signature in question. We show that, when utilising the entire human workforce, the incorporation of a machine streamlines the authentication process and decreases the expected cost for all operating conditions.
NASA Astrophysics Data System (ADS)
Beam, Craig A.
2002-04-01
Each year, approximately 60% of all US women over the age of 40 utilize mammography. Through the matrix of an imaging technology, this Population of Patients (POP) interacts with a population of approximately 20,000 physicians who interpret mammograms in the US. This latter Population of Diagnosticians (POD) operationally serves as the interface between an image-centric healthcare technology system and patient. Methods: using data collected from a large POD and POP based study, I evaluate the distribution of several ROC curve-related parameters in the POD and explore the health policy implications of a population ROC curve for mammography. Results and Conclusions: Principal Components Analysis suggests that two Binormal parameters are sufficient to explain variation in the POD and implies that the Binormal model is foundational to Health Policy Research in Mammography. A population ROC curve based on percentiles of the POD can be used to set targets to achieve national health policy goals. Medical Image Perception science provides the framework. Alternatively, a restrictive policy can be envisioned using performance criteria based on area. However, the data suggests this sort of policy would be too costly in terms of reduced healthcare service capacity in the US in the face of burgeoning demands.
Jono, Ryota; Shimizu, Kentaro
2016-01-01
Dioxygenase (dOx) utilizes stereospecific oxidation on aromatic molecules; consequently, dOx has potential applications in bioremediation and stereospecific oxidation synthesis. The reactive components of dOx comprise a Rieske structure Cys2[2Fe-2S]His2 and a non-heme reactive oxygen center (ROC). Between the Rieske structure and the ROC, a universally conserved Asp residue appears to bridge the two structures forming a Rieske-Asp-ROC triad, where the Asp is known to be essential for electron transfer processes. The Rieske and ROC share hydrogen bonds with Asp through their His ligands; suggesting an ideal network for electron transfer via the carboxyl side chain of Asp. Associated with the dOx is an itinerant charge carrying protein Ferredoxin (Fdx). Depending on the specific cognate, Fdx may also possess either the Rieske structure or a related structure known as 4-Cys-[2Fe-2S] (4-Cys). In this study, we extensively explore, at different levels of theory, the behavior of the individual components (Rieske and ROC) and their interaction together via the Asp using a variety of density function methods, basis sets, and a method known as Generalized Ionic Fragment Approach (GIFA) that permits setting up spin configurations manually. We also report results on the 4-Cys structure for comparison. The individual optimized structures are compared with observed spectroscopic data from the Rieske, 4-Cys and ROC structures (where information is available). The separate pieces are then combined together into a large Rieske-Asp-ROC (donor/bridge/acceptor) complex to estimate the overall coupling between individual components, based on changes to the partial charges. The results suggest that the partial charges are significantly altered when Asp bridges the Rieske and the ROC; hence, long range coupling through hydrogen bonding effects via the intercalated Asp bridge can drastically affect the partial charge distributions compared to the individual isolated structures. The results are consistent with a proton coupled electron transfer mechanism. PMID:27656882
Estimating the Area Under ROC Curve When the Fitted Binormal Curves Demonstrate Improper Shape.
Bandos, Andriy I; Guo, Ben; Gur, David
2017-02-01
The "binormal" model is the most frequently used tool for parametric receiver operating characteristic (ROC) analysis. The binormal ROC curves can have "improper" (non-concave) shapes that are unrealistic in many practical applications, and several tools (eg, PROPROC) have been developed to address this problem. However, due to the general robustness of binormal ROCs, the improperness of the fitted curves might carry little consequence for inferences about global summary indices, such as the area under the ROC curve (AUC). In this work, we investigate the effect of severe improperness of fitted binormal ROC curves on the reliability of AUC estimates when the data arise from an actually proper curve. We designed theoretically proper ROC scenarios that induce severely improper shape of fitted binormal curves in the presence of well-distributed empirical ROC points. The binormal curves were fitted using maximum likelihood approach. Using simulations, we estimated the frequency of severely improper fitted curves, bias of the estimated AUC, and coverage of 95% confidence intervals (CIs). In Appendix S1, we provide additional information on percentiles of the distribution of AUC estimates and bias when estimating partial AUCs. We also compared the results to a reference standard provided by empirical estimates obtained from continuous data. We observed up to 96% of severely improper curves depending on the scenario in question. The bias in the binormal AUC estimates was very small and the coverage of the CIs was close to nominal, whereas the estimates of partial AUC were biased upward in the high specificity range and downward in the low specificity range. Compared to a non-parametric approach, the binormal model led to slightly more variable AUC estimates, but at the same time to CIs with more appropriate coverage. The improper shape of the fitted binormal curve, by itself, ie, in the presence of a sufficient number of well-distributed points, does not imply unreliable AUC-based inferences. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Spectral Detection of Acute Mental Stress with VIS-SWIR Hyperspectral Imagery
2013-03-01
collected with a contact probe. The variance of “stress” (red solid lines) is lower on average than “non-stress” (blue dashed lines) because the HRV ...6 ROC Receiver Operating Characteristic . . . . . . . . . . . . . . . . . . . . . 6 HRV Heart Rate Variability...systems. A stressor involving the cognitive system manifests 7 in the form of anxiety , for example, the reaction to a quiz or speech, whereas a
ERIC Educational Resources Information Center
Tadlock, Max; And Others
A study by Management and Economic Research, Inc. (MERI) of the occupational education in a 2-county area analyzed employer and student needs and existing facilities. To reduce wasteful competition, it recommended a change from local to area planning and the organization of a Regional Occupational Center (ROC) System with subsystems in contiguous…
Evaluación de la utilidad diagnóstica de la versión española del cuestionario al informador «AD8»☆
Pardo, C. Carnero; de la Vega Cotarelo, R.; Alcalde, S. López; Aparicio, C. Martos; Carrillo, R. Vílchez; Gavilán, E. Mora; Galvin, J.E.
2012-01-01
Introducción El AD8 es un cuestionario al informador breve que puede ser autoaplicado y facilita la identificación de deterioro cognitivo (DC); nuestro objetivo es evaluar la utilidad diagnóstica (UD) de una versión española. Material y métodos Estudio transversal en una muestra clínica de díadas paciente/ informador, 330 sujetos con sospecha de DC o demencia (DEM) y 71 controles. Se ha evaluado la consistencia interna (α de Cronbach) y la validez (correlaciones parciales con estadio GDS, Fototest e índice funcional [IF]). La UD se ha evaluado para no DC vs DC (GDS 3–4) por medio del área bajo la curva ROC (aROC) y se ha considerado mejor punto de corte aquel que hacía máximo el índice de Youden. Resultados En la muestra, 105 no tenían DC, 99 tenían DC sin DEM y 203 DEM. La consistencia interna es alta (α 0,90, IC del 95%, 0,89–0,92), al igual que las correlaciones con GDS (r = 0,72, p < 0,001), Fototest (r = −0,61, p < 0,001) e IF (r = 0,59, p < 0,001). El aROC del AD8 es 0,90 (IC del 95%, 0,86–0,93), sin diferencia significativa con la del Fototest (aROC 0,93, IC del 95%, 0,89–0,96); el mejor punto de corte es 3/4 con sensibilidad de 0,93 (IC del 95%, 0,88–0,96), especificidad de 0,81 (IC del 95%, 0,72–0,88) y el 88,8% de las clasificaciones correctas. El uso conjunto de AD8 y Fototest mejora de forma significativa la UD de ambos (aROC 0,96, IC del 95%, 0,93–0,98, p < 0,05). Conclusiones La versión española del AD8 conserva las cualidades psicométricas y la UD de la versión original; su uso combinado con el Fototest mejora de forma significativa la UD de ambos. PMID:22652137
NASA Astrophysics Data System (ADS)
Courdent, Vianney; Grum, Morten; Mikkelsen, Peter Steen
2018-01-01
Precipitation constitutes a major contribution to the flow in urban storm- and wastewater systems. Forecasts of the anticipated runoff flows, created from radar extrapolation and/or numerical weather predictions, can potentially be used to optimize operation in both wet and dry weather periods. However, flow forecasts are inevitably uncertain and their use will ultimately require a trade-off between the value of knowing what will happen in the future and the probability and consequence of being wrong. In this study we examine how ensemble forecasts from the HIRLAM-DMI-S05 numerical weather prediction (NWP) model subject to three different ensemble post-processing approaches can be used to forecast flow exceedance in a combined sewer for a wide range of ratios between the probability of detection (POD) and the probability of false detection (POFD). We use a hydrological rainfall-runoff model to transform the forecasted rainfall into forecasted flow series and evaluate three different approaches to establishing the relative operating characteristics (ROC) diagram of the forecast, which is a plot of POD against POFD for each fraction of concordant ensemble members and can be used to select the weight of evidence that matches the desired trade-off between POD and POFD. In the first approach, the rainfall input to the model is calculated for each of 25 ensemble members as a weighted average of rainfall from the NWP cells over the catchment where the weights are proportional to the areal intersection between the catchment and the NWP cells. In the second approach, a total of 2825 flow ensembles are generated using rainfall input from the neighbouring NWP cells up to approximately 6 cells in all directions from the catchment. In the third approach, the first approach is extended spatially by successively increasing the area covered and for each spatial increase and each time step selecting only the cell with the highest intensity resulting in a total of 175 ensemble members. While the first and second approaches have the disadvantage of not covering the full range of the ROC diagram and being computationally heavy, respectively, the third approach leads to both a broad coverage of the ROC diagram range at a relatively low computational cost. A broad coverage of the ROC diagram offers a larger selection of prediction skill to choose from to best match to the prediction purpose. The study distinguishes itself from earlier research in being the first application to urban hydrology, with fast runoff and small catchments that are highly sensitive to local extremes. Furthermore, no earlier reference has been found on the highly efficient third approach using only neighbouring cells with the highest threat to expand the range of the ROC diagram. This study provides an efficient and robust approach to using ensemble rainfall forecasts affected by bias and misplacement errors for predicting flow threshold exceedance in urban drainage systems.
Li, Y; Tan, J Q; Mai, Z Y; Yang, D Z
2018-01-25
Objective: Explore the value of anti-Müllerian hormone (AMH) in predicting pregnant outcomes of polycystic ovary syndrome (PCOS) patients undergone assisted reproductive technology. Methods: The study totally recruited 1 697 patients who underwent the first in vitro fertilization (IVF) or intracytoplasmic sperm injection (ICSI) cycle in Sun Yat-sen Memorial Hospital from the January 2014 to December 2015. The patients were divided into two groups based on the age<35 ( n= 758) and ≥35 years old ( n= 939) , compare the basic data and pregnant outcomes of controlled ovarian hyerstimulation. Spearman correlation method was conducted to analyze the relations between AMH and clinical outcomes. The logistic regression method and partial correlation analysis were used to judge the main factors which determine pregnancy outcomes by controlled the confounding factors. The receiver operating characteristic curve (ROC) was used to evaluate the predictive sensitivity and specificity of AMH. Results: In the group of PCOS patient younger than 35 years, AMH were correlated with the number of antral follicles ( r= 0.388) and retrieved oocytes ( r= 0.235) . When the effect of total dosage and starting dosage of gonadotropin were controlled, AMH was still significantly associated with the number of retrieved oocytes ( P< 0.05) . AMH had no predictive value for the clinical pregnancy of PCOS patient younger than 35 years (area under ROC curve=0.481, P= 0.768) . In the group of PCOS patient≥35 years old, AMH were correlated with the number of antral follicles ( r= 0.450) , retrieved oocytes ( r= 0.399) , available embryo ( r= 0.336) and high quality embryo ( r= 0.235) . When the effect of total dosage and starting dosage of gonadotropin were controlled, the correlations were still significant between those indexes (all P< 0.05) . AMH had no predictive value for the clinical pregnancy of PCOS patient ≥35 years old (area under ROC curve=0.535, P= 0.560) . However, the clinical pregnancy rate of the group of PCOS patient ≥35 years old was slightly higher than the control group ( P= 0.062) . Conclusions: AMH has no predictive value for the pregnancy outcome of PCOS patient. The pregnancy rate of PCOS patient ≥35 years old is slightly higher than the younger group, because the PCOS patient may have better ovarian reserve.
Hisamatsu, Tadakazu; Okamoto, Susumu; Hashimoto, Masaki; Muramatsu, Takahiko; Andou, Ayatoshi; Uo, Michihide; Kitazume, Mina T.; Matsuoka, Katsuyoshi; Yajima, Tomoharu; Inoue, Nagamu; Kanai, Takanori; Ogata, Haruhiko; Iwao, Yasushi; Yamakado, Minoru; Sakai, Ryosei; Ono, Nobukazu; Ando, Toshihiko; Suzuki, Manabu; Hibi, Toshifumi
2012-01-01
Background Inflammatory bowel disease (IBD) is a chronic intestinal disorder that is associated with a limited number of clinical biomarkers. In order to facilitate the diagnosis of IBD and assess its disease activity, we investigated the potential of novel multivariate indexes using statistical modeling of plasma amino acid concentrations (aminogram). Methodology and Principal Findings We measured fasting plasma aminograms in 387 IBD patients (Crohn's disease (CD), n = 165; ulcerative colitis (UC), n = 222) and 210 healthy controls. Based on Fisher linear classifiers, multivariate indexes were developed from the aminogram in discovery samples (CD, n = 102; UC, n = 102; age and sex-matched healthy controls, n = 102) and internally validated. The indexes were used to discriminate between CD or UC patients and healthy controls, as well as between patients with active disease and those in remission. We assessed index performances using the area under the curve of the receiver operating characteristic (ROC AUC). We observed significant alterations to the plasma aminogram, including histidine and tryptophan. The multivariate indexes established from plasma aminograms were able to distinguish CD or UC patients from healthy controls with ROC AUCs of 0.940 (95% confidence interval (CI): 0.898–0.983) and 0.894 (95%CI: 0.853–0.935), respectively in validation samples (CD, n = 63; UC, n = 120; healthy controls, n = 108). In addition, other indexes appeared to be a measure of disease activity. These indexes distinguished active CD or UC patients from each remission patients with ROC AUCs of 0.894 (95%CI: 0.853–0.935) and 0.849 (95%CI: 0.770–0.928), and correlated with clinical disease activity indexes for CD (rs = 0.592, 95%CI: 0.385–0.742, p<0.001) or UC (rs = 0.598, 95%CI: 0.452–0.713, p<0.001), respectively. Conclusions and Significance In this study, we demonstrated that established multivariate indexes composed of plasma amino acid profiles can serve as novel, non-invasive, objective biomarkers for the diagnosis and monitoring of IBD, providing us with new insights into the pathophysiology of the disease. PMID:22303484
Testing a Neurocomputational Model of Recollection, Familiarity, and Source Recognition
ERIC Educational Resources Information Center
Elfman, Kane W.; Parks, Colleen M.; Yonelinas, Andrew P.
2008-01-01
The authors assess whether the complementary learning systems model of the medial temporal lobes (Norman & O'Reilly, 2003) is able to account for source recognition receiver operating characteristics (ROCs). The model assumes that recognition reflects the contribution of a hippocampally mediated recollection process and a cortically mediated…
2012-03-01
confidence rating (p value) (Macmillan, & Creelman , 1996). More specifically, as response bias relates to polygraph scoring, the development of the...Macmillan, N., & Creelman , C. (1996). Triangles in ROC space: History and theory of “nonparametric” measures of sensitivity and response bias
Analysis of Exhaled Breath Volatile Organic Compounds in Inflammatory Bowel Disease: A Pilot Study.
Hicks, Lucy C; Huang, Juzheng; Kumar, Sacheen; Powles, Sam T; Orchard, Timothy R; Hanna, George B; Williams, Horace R T
2015-09-01
Distinguishing between the inflammatory bowel diseases [IBD], Crohn's disease [CD] and ulcerative colitis [UC], is important for determining management and prognosis. Selected ion flow tube mass spectrometry [SIFT-MS] may be used to analyse volatile organic compounds [VOCs] in exhaled breath: these may be altered in disease states, and distinguishing breath VOC profiles can be identified. The aim of this pilot study was to identify, quantify, and analyse VOCs present in the breath of IBD patients and controls, potentially providing insights into disease pathogenesis and complementing current diagnostic algorithms. SIFT-MS breath profiling of 56 individuals [20 UC, 18 CD, and 18 healthy controls] was undertaken. Multivariate analysis included principal components analysis and partial least squares discriminant analysis with orthogonal signal correction [OSC-PLS-DA]. Receiver operating characteristic [ROC] analysis was performed for each comparative analysis using statistically significant VOCs. OSC-PLS-DA modelling was able to distinguish both CD and UC from healthy controls and from one other with good sensitivity and specificity. ROC analysis using combinations of statistically significant VOCs [dimethyl sulphide, hydrogen sulphide, hydrogen cyanide, ammonia, butanal, and nonanal] gave integrated areas under the curve of 0.86 [CD vs healthy controls], 0.74 [UC vs healthy controls], and 0.83 [CD vs UC]. Exhaled breath VOC profiling was able to distinguish IBD patients from controls, as well as to separate UC from CD, using both multivariate and univariate statistical techniques. Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
1975-01-01
Receiver operating characteristic (ROC) analysis of nerve messages is described. The hypothesis that quantum fluctuations provide the only limit to the ability of frog ganglion cells to signal luminance change information is examined using ROC analysis. In the context of ROC analysis, the quantum fluctuation hypothesis predicts (a) the detectability of a luminance change signal should rise proportionally to the size of the change, (b) detectability should decrease as the square root of background, an implication of which is the deVries-Rose law, and (c) ROC curves should exhibit a shape particular to underlying Poisson distributions. Each of these predictions is confirmed for the responses of dimming ganglion cells to brief luminance decrements at scotopic levels, but none could have been tested using classical nerve message analysis procedures. PMID:172597
Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A
2016-03-15
The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Bowles, Ben; Harlow, Iain M.; Meeking, Melissa M.; Kohler, Stefan
2012-01-01
It is widely accepted that signal-detection mechanisms contribute to item-recognition memory decisions that involve discriminations between targets and lures based on a controlled laboratory study episode. Here, the authors employed mathematical modeling of receiver operating characteristics (ROC) to determine whether and how a signal-detection…
Weiss, Bettina G; Bachmann, Lucas M; Pfirrmann, Christian W A; Kissling, Rudolf O; Zubler, Veronika
2016-02-01
Discrimination of diffuse idiopathic skeletal hyperostosis (DISH) and ankylosing spondylitis (AS) can be challenging. Usefulness of whole-body magnetic resonance imaging (WB-MRI) in diagnosing spondyloarthritis has been recently proved. We assessed the value of clinical variables alone and in combination with WB-MRI to distinguish between DISH and AS. Diagnostic case-control study: 33 patients with AS and 15 patients with DISH were included. All patients underwent 1.5 Tesla WB-MRI scanning. MR scans were read by a blinded radiologist using the Canadian-Danish Working Group's recommendation. Imaging and clinical variables were identified using the bootstrap. The most important variables from MR and clinical history were assessed in a multivariate fashion resulting in 3 diagnostic models (MRI, clinical, and combined). The discriminative capacity was quantified using the area under the receiver-operating characteristic (ROC) curve. The strength of diagnostic variables was quantified with OR. Forty-eight patients provided 1545 positive findings (193 DISH/1352 AS). The final MR model contained upper anterior corner fat infiltration (32 DISH/181 AS), ankylosis on the vertebral endplate (4 DISH/60 AS), facet joint ankylosis (4 DISH/49 AS), sacroiliac joint edema (11 DISH/91 AS), sacroiliac joint fat infiltration (2 DISH/114 AS), sacroiliac joint ankylosis (2 DISH/119 AS); area under the ROC curve was 0.71, 95% CI 0.64-0.78. The final clinical model contained patient's age and body mass index (area under the ROC curve 0.90, 95% CI 0.89-0.91). The full diagnostic model containing clinical and MR information had an area under the ROC curve of 0.93 (95% CI 0.92-0.95). WB-MRI features can contribute to the correct diagnosis after a thorough conventional workup of patients with DISH and AS.
Kawashima, Hiroki; Hayashi, Norio; Ohno, Naoki; Matsuura, Yukihiro; Sanada, Shigeru
2015-08-01
To evaluate the patient identification ability of radiographers, previous and current chest radiographs were assessed with observer study utilizing a receiver operating characteristics (ROCs) analysis. This study included portable and conventional chest radiographs from 43 same and 43 different patients. The dataset used in this study was divided into the three following groups: (1) a pair of portable radiographs, (2) a pair of conventional radiographs, and (3) a combination of each type of radiograph. Seven observers participated in this ROC study, which aimed to identify same or different patients, using these datasets. ROC analysis was conducted to calculate the average area under ROC curve obtained by each observer (AUCave), and a statistical test was performed using the multi-reader multi-case method. Comparable results were obtained with pairs of portable (AUCave: 0.949) and conventional radiographs (AUCave: 0.951). In a comparison between the same modality, there were no significant differences. In contrast, the ability to identify patients by comparing a portable and conventional radiograph (AUCave: 0.873) was lower than with the matching datasets (p=0.002 and p=0.004, respectively). In conclusion, the use of different imaging modalities reduces radiographers' ability to identify their patients.
Voice-onset time and buzz-onset time identification: A ROC analysis
NASA Astrophysics Data System (ADS)
Lopez-Bascuas, Luis E.; Rosner, Burton S.; Garcia-Albea, Jose E.
2004-05-01
Previous studies have employed signal detection theory to analyze data from speech and nonspeech experiments. Typically, signal distributions were assumed to be Gaussian. Schouten and van Hessen [J. Acoust. Soc. Am. 104, 2980-2990 (1998)] explicitly tested this assumption for an intensity continuum and a speech continuum. They measured response distributions directly and, assuming an interval scale, concluded that the Gaussian assumption held for both continua. However, Pastore and Macmillan [J. Acoust. Soc. Am. 111, 2432 (2002)] applied ROC analysis to Schouten and van Hessen's data, assuming only an ordinal scale. Their ROC curves suppported the Gaussian assumption for the nonspeech signals only. Previously, Lopez-Bascuas [Proc. Audit. Bas. Speech Percept., 158-161 (1997)] found evidence with a rating scale procedure that the Gaussian model was inadequate for a voice-onset time continuum but not for a noise-buzz continuum. Both continua contained ten stimuli with asynchronies ranging from -35 ms to +55 ms. ROC curves (double-probability plots) are now reported for each pair of adjacent stimuli on the two continua. Both speech and nonspeech ROCs often appeared nonlinear, indicating non-Gaussian signal distributions under the usual zero-variance assumption for response criteria.
An Overview of Communications Technology and Development Efforts for 2015 SBIR Phase I
NASA Technical Reports Server (NTRS)
Nguyen, Hung D.; Steele, Gynelle C.
2017-01-01
This report highlights innovative SBIR 2015 Phase I projects specifically addressing areas in Communications Technology and Development which is one of six core competencies at NASA Glenn Research Center. There are fifteen technologies featured with emphasis on a wide spectrum of applications such as novel solid state lasers for space-based water vapor dial; wide temperature, high voltage and energy density capacitors for aerospace exploration; instrument for airborne measurement of carbonyl sulfide; high-power tunable seed laser for methane Lidar transmitter; ROC-rib deployable ka-band antenna for nanosatellites; a SIC-based microcontroller for high-temperature in-situ instruments and systems; improved yield, performance and reliability of high-actuator-count deformable mirrors; embedded multifunctional optical sensor system; switching electronics for space-based telescopes with advanced AO systems; integrated miniature DBR laser module for Lidar instruments; and much more. Each article in this booklet describes an innovation, technical objective, and highlights NASA commercial and industrial applications. space-based water vapor dial; wide temperature, high voltage and energy density capacitors foraerospace exploration; instrument for airborne measurement of carbonyl sulfide; high-power tunable seed laser formethane Lidar transmitter; ROC-rib deployable ka-band antenna for nanosatellites.
Mussap, Michele; Puxeddu, Elisabetta; Puddu, Melania; Ottonello, Giovanni; Coghe, Ferdinando; Comite, Paola; Cibecchini, Francesco; Fanos, Vassilios
2015-12-07
Neonatal sepsis still remains a major cause of morbidity and mortality in neonatal intensive care unit (NICU). Recently, soluble CD14 subtype (sDC14-ST) also named presepsin, was proposed as an effective biomarker for diagnosing, monitoring, and assessing the risk of neonatal sepsis and septic shock. The aim of this study was to investigate the diagnostic accuracy of sCD14-ST presepsin in diagnosing neonatal bacterial sepsis and in discriminating non-bacterial systemic inflammatory response syndrome (SIRS) from bacterial sepsis. This study involved 65 critically ill full-term and preterm newborns admitted to the neonatal intensive care unit (NICU), divided into three groups: 25 newborns with bacterial neonatal sepsis (group A); 15 newborns with a diagnosis of non-bacterial SIRS and with no localizing source of bacterial infection (group B); and 25 babies with no clinical or bacteriological signs of systemic or local infection receiving routine NICU care, most of them treated with phototherapy for neonatal jaundice (group C). A total of 102 whole blood samples were collected, 40 in group A, 30 in group B and 32 in group C. In 10 babies included in group A, sCD14-ST presepsin was also measured in an additional second blood sample collected 3 days after the start of antibiotic treatment. sCD14-ST presepsin was measured by a commercially available chemiluminescent enzyme immunoassay (CLEIA) optimized on an automated immunoassay analyzer. Statistical analysis was performed by means of MedCalc® statistical package; receiver operating characteristic (ROC) analysis was computed, and the area under the ROC curve (AUC) was used to evaluate the ability of sCD14-ST to discriminate neonatal bacterial sepsis from non-bacterial SIRS. Blood sCD14-ST presepsin levels were found significantly higher in bacterial sepsis when compared with controls (p<0.0001); similarly, they were higher in non-bacterial SIRS when compared with controls (p<0.0001). However, no statistically significant difference was found between bacterial sepsis and non-bacterial SIRS (p=0.730). In our population, CRP and sCD14-ST did not correlate with each other. ROC analysis revealed that sCD14-ST presepsin has an area under the curve (AUC) of 0.995 (95% C.I.: 0.941-1.00) greater than that of CRP (0.827; 95% C.I.: 0.72-0.906). Similarly, in the group of babies with non-infectious SIRS, sCD14-ST AUC was greater than CRP AUC (0.979; 95% C.I.: 0.906-0.999 versus 0.771; 95% C.I.: 0.647-0.868). In controls, preliminary reference intervals for sCD14-ST ranged 223.4-599.7 ng/L, being significantly different from those previously published elsewhere. In conclusion, sCD14-ST presepsin could be introduced in clinical practice as a diagnostic tool for improving the management of neonatal sepsis and non-bacterial SIRS. Copyright © 2015 Elsevier B.V. All rights reserved.
Narrowing of ischiofemoral and quadratus femoris spaces in pediatric ischiofemoral impingement.
Goldberg-Stein, Shlomit; Friedman, Avi; Gao, Qi; Choi, Jaeun; Schulz, Jacob; Fornari, Eric; Taragin, Benjamin
2018-05-05
To correlate MRI findings of quadratus femoris muscle edema (QFME) with narrowing of the ischiofemoral space (IFS) and quadratus femoris space (QFS) in children, and to identify threshold values reflecting an anatomic architecture that may predispose to ischiofemoral impingement. A case-control retrospective MRI review of 49 hips in 27 children (mean, 13 years) with QFME was compared to 49 hips in 27 gender and age-matched controls. Two radiologists independently measured IFS and QFS. Generalized linear mixed-effects models were fit to compare IFS and QFS values between cases and controls, and adjust for correlation in repeated measures from the same subject. Receiver operating characteristic (ROC) analysis determined optimal threshold values. Compared to controls, cases had significantly smaller IFS (p < 0.001, both readers) and QFS (reader 1: p < 0.001; reader 2: p = 0.003). When stratified as preteen (< 13) or teenage (≥ 13), lower mean IFS and QFS were observed in cases versus controls in both age groups. Area under ROC curve for IFS and QFS was high in preteens (0.77 and 0.71) and teens (0.94 and 0.88). Threshold values were 14.9 mm (preteens) and 19 mm (teens) for IFS and 11.2 mm (preteens) and 11.1 mm (teens) for QFS. IFS and QFS were modestly correlated with age among controls only. Pediatric patients with QFME had significantly narrower QFS and IFS compared with controls. IFS and QFS were found to normally increase in size with age. Optimal cutoff threshold values were identified for QFS and IFS in preteens and teenagers.
CFD analysis of turboprop engine oil cooler duct for best rate of climb condition
NASA Astrophysics Data System (ADS)
Kalia, Saurabh; CA, Vinay; Hegde, Suresh M.
2016-09-01
Turboprop engines are widely used in commuter category airplanes. Aircraft Design bureaus routinely conduct the flight tests to confirm the performance of the system. The lubrication system of the engine is designed to provide a constant supply of clean lubrication oil to the engine bearings, the reduction gears, the torque-meter, the propeller and the accessory gearbox. The oil lubricates, cools and also conducts foreign material to the oil filter where it is removed from further circulation. Thus a means of cooling the engine oil must be provided and a suitable oil cooler (OC) and ducting system was selected and designed for this purpose. In this context, it is relevant to study and analyse behaviour of the engine oil cooler system before commencing actual flight tests. In this paper, the performance of the oil cooler duct with twin flush NACA inlet housed inside the nacelle has been studied for aircraft best rate of climb (ROC) condition using RANS based SST K-omega model by commercial software ANSYS Fluent 13.0. From the CFD analysis results, it is found that the mass flow rate captured and pressure drop across the oil cooler for the best ROC condition is meeting the oil cooler manufacturer requirements thus, the engine oil temperature is maintained within prescribed limits.
Embree, Lindsay M; Budson, Andrew E; Ally, Brandon A
2012-07-01
Understanding how memory breaks down in the earliest stages of Alzheimer's disease (AD) process has significant implications, both clinically and with respect to intervention development. Previous work has highlighted a robust picture superiority effect in patients with amnestic mild cognitive impairment (aMCI). However, it remains unclear as to how pictures improve memory compared to words in this patient population. In the current study, we utilized receiver operating characteristic (ROC) curves to obtain estimates of familiarity and recollection for pictures and words in patients with aMCI and healthy older controls. Analysis of accuracy shows that even when performance is matched between pictures and words in the healthy control group, patients with aMCI continue to show a significant picture superiority effect. The results of the ROC analysis showed that patients demonstrated significantly impaired recollection and familiarity for words compared controls. In contrast, patients with aMCI demonstrated impaired recollection, but intact familiarity for pictures, compared to controls. Based on previous work from our lab, we speculate that patients can utilize the rich conceptual information provided by pictures to enhance familiarity, and perceptual information may allow for post-retrieval monitoring or verification of the enhanced sense of familiarity. Alternatively, the combination of enhanced conceptual and perceptual fluency of the test item might drive a stronger or more robust sense of familiarity that can be accurately attributed to a studied item. Copyright © 2012 Elsevier Ltd. All rights reserved.
Embree, Lindsay M.; Budson, Andrew E.; Ally, Brandon A.
2012-01-01
Understanding how memory breaks down in the earliest stages of the Alzheimer’s disease (AD) process has significant implications, both clinically and with respect to intervention development. Previous work has highlighted a robust picture superiority effect in patients with amnestic mild cognitive impairment (aMCI). However, it remains unclear as to how pictures improve memory compared to words in this patient population. In the current study, we utilized receiver operating characteristic (ROC) curves to obtain estimates of familiarity and recollection for pictures and words in patients with aMCI and healthy older controls. Analysis of accuracy shows that even when performance is matched between pictures and words in the healthy control group, patients with aMCI continue to show a significant picture superiority effect. The results of the ROC analysis showed that patients demonstrated significantly impaired recollection and familiarity for words compared controls. In contrast, patients with aMCI demonstrated impaired recollection, but intact familiarity for pictures, compared to controls. Based on previous work from our lab, we speculate that patients can utilize the rich conceptual information provided by pictures to enhance familiarity, and perceptual information may allow for post-retrieval monitoring or verification of the enhanced sense of familiarity. Alternatively, the combination of enhanced conceptual and perceptual fluency of the test item might drive a stronger or more robust sense of familiarity that can be accurately attributed to a studied item. PMID:22705441
NASA Astrophysics Data System (ADS)
Yulistiani, D.; Nurhayati
2018-02-01
Utilization of crop by-products such as maize straw mixed with legume is expected to be able to overcome the limitation of forage availability during dry season and have similar nutritional value with grass. Addition of fermentable carbohydrate in this diet can be improved fermentability and reduced methane production. The objective of this study was to evaluate supplementation of ground corn grain or rice bran as fermentable carbohydrate in maize straw-gliricidiamixture. Treatment diets evaluated were: Maize straw + gliricidialeaf meal (Control/RO); Control + 10% ground maize grain (ROC); Control + 10% rice bran (RORB). Maize straw was chopped and ground then mixed with gliricidia leaf meal at ratio 60:40% DM. Maize straw-gliricidia mixture then supplemented either with ground corn grain or rice bran at 10% of DM basal diet (control). Sample was incubated for 48 hours, gas production was recorded at 4, 8,12, 16, 24, 36 and 48 hours. Study was conducted in randomized complete design. Results of the study showed that supplementation of fermentable carbohydrate from corn grain or rice bran was able to increased (P<0.05) rate of gas production by 24 and 18% respectively. However only in ROC potential gas production was increased (P<0.05) by 32% and percentage of methane production was decreased. From this study it can be concluded that supplementation of ground corn grain at 10% in maize straw-gliricidia mixture was able to improve diet fermentation and reduced methane production.
ROC curve analyses of eyewitness identification decisions: An analysis of the recent debate.
Rotello, Caren M; Chen, Tina
2016-01-01
How should the accuracy of eyewitness identification decisions be measured, so that best practices for identification can be determined? This fundamental question is under intense debate. One side advocates for continued use of a traditional measure of identification accuracy, known as the diagnosticity ratio , whereas the other side argues that receiver operating characteristic curves (ROCs) should be used instead because diagnosticity is confounded with response bias. Diagnosticity proponents have offered several criticisms of ROCs, which we show are either false or irrelevant to the assessment of eyewitness accuracy. We also show that, like diagnosticity, Bayesian measures of identification accuracy confound response bias with witnesses' ability to discriminate guilty from innocent suspects. ROCs are an essential tool for distinguishing memory-based processes from decisional aspects of a response; simulations of different possible identification tasks and response strategies show that they offer important constraints on theory development.
On the form of ROCs constructed from confidence ratings.
Malmberg, Kenneth J
2002-03-01
A classical question for memory researchers is whether memories vary in an all-or-nothing, discrete manner (e.g., stored vs. not stored, recalled vs. not recalled), or whether they vary along a continuous dimension (e.g., strength, similarity, or familiarity). For yes-no classification tasks, continuous- and discrete-state models predict nonlinear and linear receiver operating characteristics (ROCs), respectively (D. M. Green & J. A. Swets, 1966; N. A. Macmillan & C. D. Creelman, 1991). Recently, several authors have assumed that these predictions are generalizable to confidence ratings tasks (J. Qin, C. L. Raye, M. K. Johnson, & K. J. Mitchell, 2001; S. D. Slotnick, S. A. Klein, C. S. Dodson, & A. P. Shimamura, 2000, and A. P. Yonelinas, 1999). This assumption is shown to be unwarranted by showing that discrete-state ratings models predict both linear and nonlinear ROCs. The critical factor determining the form of the discrete-state ROC is the response strategy adopted by the classifier.
ROC analysis of diagnostic performance in liver scintigraphy.
Fritz, S L; Preston, D F; Gallagher, J H
1981-02-01
Studies on the accuracy of liver scintigraphy for the detection of metastases were assembled from 38 sources in the medical literature. An ROC curve was fitted to the observed values of sensitivity and specificity using an algorithm developed by Ogilvie and Creelman. This ROC curve fitted the data better than average sensitivity and specificity values in each of four subsets of the data. For the subset dealing with Tc-99m sulfur colloid scintigraphy, performed for detection of suspected metastases and containing data on 2800 scans from 17 independent series, it was not possible to reject the hypothesis that interobserver variation was entirely due to the use of different decision thresholds by the reporting clinicians. Thus the ROC curve obtained is a reasonable baseline estimate of the performance potentially achievable in today's clinical setting. Comparison of new reports with these data is possible, but is limited by the small sample sizes in most reported series.
Use of the ROC anchor in foot and ankle surgery. A retrospective study.
Kuwada, G T
1999-05-01
A retrospective study was conducted on the use of the ROC (Radial Osteo Compression) soft-tissue anchor in foot and ankle surgery. This article describes how the anchor is deployed, problematic aspects of using the anchor, and complications and success rates associated with the anchor in ankle stabilizations, posterior tibial tendon reconstruction, peroneus brevis tendon reconstruction after fracture of the base of the fifth metatarsal, and detachment and reattachment of the Achilles tendon. The ROC anchor consists of the anchor with nonabsorbable suture attached to the shaft, the deployment handle, and drill bits. The anchor and shaft are snapped into the deployment handle and inserted into the drill hole. Compression of the trigger deploys the anchor into the hole. The ROC anchor was found to be reliable, useful, and relatively easy to deploy, with outcomes similar to those of other soft-tissue anchors.
Malaria epidemiological research in the Republic of Congo.
Koukouikila-Koussounda, Felix; Ntoumi, Francine
2016-12-23
Reliable and comprehensive information on the burden of malaria is critical for guiding national and international efforts in malaria control. The purpose of this review is to provide an overview of published data and available information on malaria resulting from field studies/investigations conducted in the Republic of Congo (RoC) from 1992 to 2015, as baseline for assisting public health authorities and researchers to define future research priorities as well as interventions. This review considers data from peer-reviewed articles and information from the National Malaria Control Programme reports, based on field investigations or samples collected from 1992 to 2015. Peer-reviewed papers were searched throughout online bibliographic databases PubMed, HINARI and Google Scholar using the following terms: "malaria", "Congo", "Brazzaville", "prevalence", "antimalarial", "efficacy", "falciparum", "genetic", "diversity". Original articles and reviews were included and selection of relevant papers was made. Twenty-eight published articles were included in this review and two additional records from the National Malaria Control Programme were also considered. The majority of studies were conducted in Brazzaville and Pointe-Noire. The present systematic review reveals that number of studies have been conducted in the RoC with regard to malaria. However, their results cannot formally be generalized at the country level. This suggests a need for implementing regular multisite investigations and surveys that may be representative of the country, calling for the support and lead of the Ministry of Health.
Examining Classification Criteria: A Comparison of Three Cut Score Methods
ERIC Educational Resources Information Center
DiStefano, Christine; Morgan, Grant
2011-01-01
This study compared 3 different methods of creating cut scores for a screening instrument, T scores, receiver operating characteristic curve (ROC) analysis, and the Rasch rating scale method (RSM), for use with the Behavioral and Emotional Screening System (BESS) Teacher Rating Scale for Children and Adolescents (Kamphaus & Reynolds, 2007).…
2007-04-20
assistance, particularly Dr. Herb Nelson and Dr. Dan Steinhurst. 1 Executive Summary Background. The remediation of sites contaminated with...and applications,” Proc. of IEEE Intl. Conf. on Multisensor Fusion and Integration for Intelligent Systems, Taipei, Taiwan , R.O.C., Aug., 1999. 4
Curriculum Standards of Technological and Vocational Education in Taiwan, R.O.C.
ERIC Educational Resources Information Center
Lee, Lung-Sheng Steven; Hwang, Jenq-Jye
In Taiwan, curriculum standards for senior vocational schools and junior colleges are administered and promulgated by the Ministry of Education approximately every 10 years. Curricula for institutes of technology are principally school based. As a result of critiques of the current top-down or administration-based approach system of curriculum…
Bolorunduro, O B; Villegas, C; Oyetunji, T A; Haut, E R; Stevens, K A; Chang, D C; Cornwell, E E; Efron, D T; Haider, A H
2011-03-01
The Injury Severity Score (ISS) is the most commonly used measure of injury severity. The score has been shown to have excellent predictive capability for trauma mortality and has been validated in multiple data sets. However, the score has never been tested to see if its discriminatory ability is affected by differences in race and gender. This study is aimed at validating the ISS in men and women and in three different race/ethnic groups using a nationwide database. Retrospective analysis of patients age 18-64 y in the National Trauma Data Bank 7.0 with blunt trauma was performed. ISS was categorized as mild (<9,) moderate (9-15), severe (16-25), and profound (>25). Logistic regression was done to measure the relative odds of mortality associated with a change in ISS categories. The discriminatory ability was compared using the receiver operating characteristics curves (ROC). A P value testing the equality of the ROC curves was calculated. Age stratified analyses were also conducted. A total of 872,102 patients had complete data for the analysis on ethnicity, while 763,549 patients were included in the gender analysis. The overall mortality rate was 3.7%. ROC in Whites was 0.8617, in Blacks 0.8586, and in Hispanics 0.8869. Hispanics have a statistically significant higher ROC (P value < 0.001). Similar results were observed within each age category. ROC curves were also significantly higher in females than in males. The ISS possesses excellent discriminatory ability in all populations as indicated by the high ROCs. Copyright © 2011 Elsevier Inc. All rights reserved.
ROC curves in clinical chemistry: uses, misuses, and possible solutions.
Obuchowski, Nancy A; Lieber, Michael L; Wians, Frank H
2004-07-01
ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas >/=0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.
Diagnostic depressive symptoms of the mixed bipolar episode.
Cassidy, F; Ahearn, E; Murry, E; Forest, K; Carroll, B J
2000-03-01
There is not yet consensus on the best diagnostic definition of mixed bipolar episodes. Many have suggested the DSM-III-R/-IV definition is too rigid. We propose alternative criteria using data from a large patient cohort. We evaluated 237 manic in-patients using DSM-III-R criteria and the Scale for Manic States (SMS). A bimodally distributed factor of dysphoric mood has been reported from the SMS data. We used both the factor and the DSM-III-R classifications to identify candidate depressive symptoms and then developed three candidate depressive symptom sets. Using ROC analysis we determined the optimal threshold number of symptoms in each set and compared the three ROC solutions. The optimal solution was tested against the DSM-III-R classification for crossvalidation. The optimal ROC solution was a set, derived from both the DSM-III-R and the SMS, and the optimal threshold for diagnosis was two or more symptoms. Applying this set iteratively to the DSM-III-R classification produced the identical ROC solution. The prevalence of mixed episodes in the cohort was 13.9% by DSM-III-R, 20.2% by the dysphoria factor and 27.4% by the new ROC solution. A diagnostic set of six dysphoric symptoms (depressed mood, anhedonia, guilt, suicide, fatigue and anxiety), with a threshold of two symptoms, is proposed for a mixed episode. This new definition has a foundation in clinical data, in the proved diagnostic performance of the qualifying symptoms, and in ROC validation against two previous definitions that each have face validity.
Wet Deposition Flux of Reactive Organic Carbon
NASA Astrophysics Data System (ADS)
Safieddine, S.; Heald, C. L.
2016-12-01
Reactive organic carbon (ROC) is the sum of non-methane volatile organic compounds (NMVOCs) and primary and secondary organic aerosols (OA). ROC plays a key role in driving the chemistry of the atmosphere, affecting the hydroxyl radical concentrations, methane lifetime, ozone formation, heterogeneous chemical reactions, and cloud formation, thereby impacting human health and climate. Uncertainties on the lifecycle of ROC in the atmosphere remain large. In part this can be attributed to the large uncertainties associated with the wet deposition fluxes. Little is known about the global magnitude of wet deposition as a sink of both gas and particle phase organic carbon, making this an important area for research and sensitivity testing in order to better understand the global ROC budget. In this study, we simulate the wet deposition fluxes of the reactive organic carbon of the troposphere using a global chemistry transport model, GEOS-Chem. We start by showing the current modeled global distribution of ROC wet deposition fluxes and investigate the sensitivity of these fluxes to variability in Henry's law solubility constants and spatial resolution. The average carbon oxidation state (OSc) is a useful metric that depicts the degree of oxidation of atmospheric reactive carbon. Here, we present for the first time the simulated gas and particle phase OSc of the global troposphere. We compare the OSc in the wet deposited reactive carbon flux and the dry deposited reactive carbon flux to the OSc of atmospheric ROC to gain insight into the degree of oxidation in deposited material and, more generally, the aging of organic material in the troposphere.
Goodman, Corey W.; Major, Heather J.; Walls, William D.; Sheffield, Val C.; Casavant, Thomas L.; Darbro, Benjamin W.
2016-01-01
Chromosomal microarrays (CMAs) are routinely used in both research and clinical laboratories; yet, little attention has been given to the estimation of genome-wide true and false negatives during the assessment of these assays and how such information could be used to calibrate various algorithmic metrics to improve performance. Low-throughput, locus-specific methods such as fluorescence in situ hybridization (FISH), quantitative PCR (qPCR), or multiplex ligation-dependent probe amplification (MLPA) preclude rigorous calibration of various metrics used by copy number variant (CNV) detection algorithms. To aid this task, we have established a comparative methodology, CNV-ROC, which is capable of performing a high throughput, low cost, analysis of CMAs that takes into consideration genome-wide true and false negatives. CNV-ROC uses a higher resolution microarray to confirm calls from a lower resolution microarray and provides for a true measure of genome-wide performance metrics at the resolution offered by microarray testing. CNV-ROC also provides for a very precise comparison of CNV calls between two microarray platforms without the need to establish an arbitrary degree of overlap. Comparison of CNVs across microarrays is done on a per-probe basis and receiver operator characteristic (ROC) analysis is used to calibrate algorithmic metrics, such as log2 ratio threshold, to enhance CNV calling performance. CNV-ROC addresses a critical and consistently overlooked aspect of analytical assessments of genome-wide techniques like CMAs which is the measurement and use of genome-wide true and false negative data for the calculation of performance metrics and comparison of CNV profiles between different microarray experiments. PMID:25595567
Comparison of ISS, NISS, and RTS score as predictor of mortality in pediatric fall.
Soni, Kapil Dev; Mahindrakar, Santosh; Gupta, Amit; Kumar, Subodh; Sagar, Sushma; Jhakal, Ashish
2017-01-01
Studies to identify an ideal trauma score tool representing prediction of outcomes of the pediatric fall patient remains elusive. Our study was undertaken to identify better predictor of mortality in the pediatric fall patients. Data was retrieved from prospectively maintained trauma registry project at level 1 trauma center developed as part of Multicentric Project-Towards Improving Trauma Care Outcomes (TITCO) in India. Single center data retrieved from a prospectively maintained trauma registry at a level 1 trauma center, New Delhi, for a period ranging from 1 October 2013 to 17 February 2015 was evaluated. Standard anatomic scores Injury Severity Score (ISS) and New Injury Severity Score (NISS) were compared with physiologic score Revised Trauma Score (RTS) using receiver operating curve (ROC). Heart rate and RTS had a statistical difference among the survivors to nonsurvivors. ISS, NISS, and RTS were having 50, 50, and 86% of area under the curve on ROCs, and RTS was statistically significant among them. Physiologically based trauma score systems (RTS) are much better predictors of inhospital mortality in comparison to anatomical based scoring systems (ISS and NISS) for unintentional pediatric falls.
NASA Astrophysics Data System (ADS)
Xu, Lili; Luo, Shuqian
2010-11-01
Microaneurysms (MAs) are the first manifestations of the diabetic retinopathy (DR) as well as an indicator for its progression. Their automatic detection plays a key role for both mass screening and monitoring and is therefore in the core of any system for computer-assisted diagnosis of DR. The algorithm basically comprises the following stages: candidate detection aiming at extracting the patterns possibly corresponding to MAs based on mathematical morphological black top hat, feature extraction to characterize these candidates, and classification based on support vector machine (SVM), to validate MAs. Feature vector and kernel function of SVM selection is very important to the algorithm. We use the receiver operating characteristic (ROC) curve to evaluate the distinguishing performance of different feature vectors and different kernel functions of SVM. The ROC analysis indicates the quadratic polynomial SVM with a combination of features as the input shows the best discriminating performance.
Xu, Lili; Luo, Shuqian
2010-01-01
Microaneurysms (MAs) are the first manifestations of the diabetic retinopathy (DR) as well as an indicator for its progression. Their automatic detection plays a key role for both mass screening and monitoring and is therefore in the core of any system for computer-assisted diagnosis of DR. The algorithm basically comprises the following stages: candidate detection aiming at extracting the patterns possibly corresponding to MAs based on mathematical morphological black top hat, feature extraction to characterize these candidates, and classification based on support vector machine (SVM), to validate MAs. Feature vector and kernel function of SVM selection is very important to the algorithm. We use the receiver operating characteristic (ROC) curve to evaluate the distinguishing performance of different feature vectors and different kernel functions of SVM. The ROC analysis indicates the quadratic polynomial SVM with a combination of features as the input shows the best discriminating performance.
Networked Operations of Hybrid Radio Optical Communications Satellites
NASA Technical Reports Server (NTRS)
Hylton, Alan; Raible, Daniel
2014-01-01
In order to address the increasing communications needs of modern equipment in space, and to address the increasing number of objects in space, NASA is demonstrating the potential capability of optical communications for both deep space and near-Earth applications. The Integrated Radio Optical Communications (iROC) is a hybrid communications system that capitalizes on the best of both the optical and RF domains while using each technology to compensate for the other's shortcomings. Specifically, the data rates of the optical links can be higher than their RF counterparts, whereas the RF links have greater link availability. The focus of this paper is twofold: to consider the operations of one or more iROC nodes from a networking point of view, and to suggest specific areas of research to further the field. We consider the utility of Disruption Tolerant Networking (DTN) and the Virtual Mission Operation Center (VMOC) model.
Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Keller, Jonathan A.; Wade, Daniel R.
2008-01-01
Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.
Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Keller, Jonathan A.; Wade, Daniel R.
2009-01-01
Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.
Kapucu, Aycan; Macmillan, Neil A.; Rotello, Caren M.
2010-01-01
Using old-new ratings and remember-know judgments we explored the plurals paradigm, in which studied words must be distinguished from plurality-changed lures. The paradigm allowed us to investigate negative remembering, that is, the remembering of a plural-altered study item; capacity for this judgment was found to be poorer than or equivalent to the conventional positive remembering. A response-bias manipulation affected positive but not negative remembering. The ratings were used to construct ROC curves and test the prediction of the most common dual-process theory of recognition memory (Yonelinas, 2001) that the amount of recollection can be independently estimated from ROC curves and from remember judgments. By fitting the individual data with pure signal-detection (SDT) models and dual-process models that combined SDT and threshold components (HTSDT), we identified two types of subjects. For those who were better described by HTSDT, the predicted convergence of remember-know and ROC measures was observed. For those who were better described by SDT the ROC intercept could not predict the remember rate. The data are consistent with the idea that all subjects rely on the same representation but base their decisions on different partitions of a decision space. PMID:20551335
Vexler, Albert; Yu, Jihnhee
2018-04-13
A common statistical doctrine supported by many introductory courses and textbooks is that t-test type procedures based on normally distributed data points are anticipated to provide a standard in decision-making. In order to motivate scholars to examine this convention, we introduce a simple approach based on graphical tools of receiver operating characteristic (ROC) curve analysis, a well-established biostatistical methodology. In this context, we propose employing a p-values-based method, taking into account the stochastic nature of p-values. We focus on the modern statistical literature to address the expected p-value (EPV) as a measure of the performance of decision-making rules. During the course of our study, we extend the EPV concept to be considered in terms of the ROC curve technique. This provides expressive evaluations and visualizations of a wide spectrum of testing mechanisms' properties. We show that the conventional power characterization of tests is a partial aspect of the presented EPV/ROC technique. We desire that this explanation of the EPV/ROC approach convinces researchers of the usefulness of the EPV/ROC approach for depicting different characteristics of decision-making procedures, in light of the growing interest regarding correct p-values-based applications.
Zhu, Luchang; Olsen, Randall J; Horstmann, Nicola; Shelburne, Samuel A; Fan, Jia; Hu, Ye; Musser, James M
2016-07-01
Variable-number tandem-repeat (VNTR) polymorphisms are ubiquitous in bacteria. However, only a small fraction of them has been functionally studied. Here, we report an intergenic VNTR polymorphism that confers an altered level of toxin production and increased virulence in Streptococcus pyogenes The nature of the polymorphism is a one-unit deletion in a three-tandem-repeat locus upstream of the rocA gene encoding a sensor kinase. S. pyogenes strains with this type of polymorphism cause human infection and produce significantly larger amounts of the secreted cytotoxins S. pyogenes NADase (SPN) and streptolysin O (SLO). Using isogenic mutant strains, we demonstrate that deleting one or more units of the tandem repeats abolished RocA production, reduced CovR phosphorylation, derepressed multiple CovR-regulated virulence factors (such as SPN and SLO), and increased virulence in a mouse model of necrotizing fasciitis. The phenotypic effect of the VNTR polymorphism was nearly the same as that of inactivating the rocA gene. In summary, we identified and characterized an intergenic VNTR polymorphism in S. pyogenes that affects toxin production and virulence. These new findings enhance understanding of rocA biology and the function of VNTR polymorphisms in S. pyogenes. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Significance of MPEG-7 textural features for improved mass detection in mammography.
Eltonsy, Nevine H; Tourassi, Georgia D; Fadeev, Aleksey; Elmaghraby, Adel S
2006-01-01
The purpose of the study is to investigate the significance of MPEG-7 textural features for improving the detection of masses in screening mammograms. The detection scheme was originally based on morphological directional neighborhood features extracted from mammographic regions of interest (ROIs). Receiver Operating Characteristics (ROC) was performed to evaluate the performance of each set of features independently and merged into a back-propagation artificial neural network (BPANN) using the leave-one-out sampling scheme (LOOSS). The study was based on a database of 668 mammographic ROIs (340 depicting cancer regions and 328 depicting normal parenchyma). Overall, the ROC area index of the BPANN using the directional morphological features was Az=0.85+/-0.01. The MPEG-7 edge histogram descriptor-based BPNN showed an ROC area index of Az=0.71+/-0.01 while homogeneous textural descriptors using 30 and 120 channels helped the BPNN achieve similar ROC area indexes of Az=0.882+/-0.02 and Az=0.877+/-0.01 respectively. After merging the MPEG-7 homogeneous textural features with the directional neighborhood features the performance of the BPANN increased providing an ROC area index of Az=0.91+/-0.01. MPEG-7 homogeneous textural descriptor significantly improved the morphology-based detection scheme.
We are requesting the reference set, which includes 50 HCC cases and 50 cirrhotic controls. In our preliminary study, AFP had a AUROC of 0.66 while the AUROC for the 5 glycoproteins was 0.81. The sensitivity and specificity for the 5 glycoproteins was 79% and 72% at the point that maximizes sensitivity+specificity in the ROC curve, and it was 79% and 35%, respectively, for AFP at the same point in the ROC curve. The reference set will allow us to determine the best performance of the 5 glycoproteins by themselves or whether their combination has a better sensitivity and/or specificity and AUROC. While a direct comparison with AFP will be made, the reference set will not allow a robust comparison due to the low sample size. If the glycoproteins are complementary or have better performance than AFP, then the next step would be to test them in the entire phase 2 hepatocellular carcinoma set.
Liver Rapid Reference Set Application ( #2): Lubman - Univ of Michigan (2010) — EDRN Public Portal
We are requesting the reference set, which includes 50 HCC cases and 50 cirrhotic controls. In our preliminary study, AFP had a AUROC of 0.66 while the AUROC for the 5 glycoproteins was 0.81. The sensitivity and specificity for the 5 glycoproteins was 79% and 72% at the point that maximizes sensitivity+specificity in the ROC curve, and it was 79% and 35%, respectively, for AFP at the same point in the ROC curve. The reference set will allow us to determine the best performance of the 5 glycoproteins by themselves or whether their combination has a better sensitivity and/or specificity and AUROC. While a direct comparison with AFP will be made, the reference set will not allow a robust comparison due to the low sample size. If the glycoproteins are complementary or have better performance than AFP, then the next step would be to test them in the entire phase 2 hepatocellular carcinoma set.
Carosella, Victorio C; Navia, Jose L; Al-Ruzzeh, Sharif; Grancelli, Hugo; Rodriguez, Walter; Cardenas, Cesar; Bilbao, Jorge; Nojek, Carlos
2009-08-01
This study aims to develop the first Latin-American risk model that can be used as a simple, pocket-card graphic score at bedside. The risk model was developed on 2903 patients who underwent cardiac surgery at the Spanish Hospital of Buenos Aires, Argentina, between June 1994 and December 1999. Internal validation was performed on 708 patients between January 2000 and June 2001 at the same center. External validation was performed on 1087 patients between February 2000 and January 2007 at three other centers in Argentina. In the development dataset the area under receiver operating characteristics (ROC) curve was 0.73 and the Hosmer-Lemeshow (HL) test was P=0.88. In the internal validation ROC curve was 0.77. In the external validation ROC curve was 0.81, but imperfect calibration was detected because the observed in-hospital mortality (3.96%) was significantly lower than the development dataset (8.20%) (P<0.0001). Recalibration was done in 2007, showing excellent level of agreement between the observed and predicted mortality rates on all patients (P=0.92). This is the first risk model for cardiac surgery developed in a population of Latin-America with both internal and external validation. A simple graphic pocket-card score allows an easy bedside application with acceptable statistic precision.
Ka-Band Link Study and Analysis for a Mars Hybrid RF/Optical Software Defined Radio
NASA Technical Reports Server (NTRS)
Zeleznikar, Daniel J.; Nappier, Jennifer M.; Downey, Joseph A.
2014-01-01
The integrated radio and optical communications (iROC) project at the NASA Glenn Research Center (GRC) is investigating the feasibility of a hybrid RF and optical communication subsystem for future deep space missions. The hybrid communications subsystem enables the advancement of optical communications while simultaneously mitigating the risk of infusion by combining an experimental optical transmitter and telescope with a reliable Ka-band RF transmitter and antenna. The iROC communications subsystem seeks to maximize the total data return over the course of a potential 2-year mission in Mars orbit beginning in 2021. Although optical communication by itself offers potential for greater data return over RF, the reliable Ka-band link is also being designed for high data return capability in this hybrid system. A daily analysis of the RF link budget over the 2-year span is performed to optimize and provide detailed estimates of the RF data return. In particular, the bandwidth dependence of these data return estimates is analyzed for candidate waveforms. In this effort, a data return modeling tool was created to analyze candidate RF modulation and coding schemes with respect to their spectral efficiency, amplifier output power back-off, required digital to analog conversion (DAC) sampling rates, and support by ground receivers. A set of RF waveforms is recommended for use on the iROC platform.
Evaluation of community-acquired sepsis by PIRO system in the emergency department.
Chen, Yun-Xia; Li, Chun-Sheng
2013-09-01
The predisposition, infection/insult, response, and organ dysfunction (PIRO) staging system for septic patients allows grouping of heterogeneous patients into homogeneous subgroups. The purposes of this single-center, prospective, observational cohort study were to create a PIRO system for patients with community-acquired sepsis (CAS) presenting to the emergency department (ED) and assess its prognostic and stratification capabilities. Septic patients were enrolled and allocated to derivation (n = 831) or validation (n = 860) cohorts according to their enrollment dates. The derivation cohort was used to identify independent predictors of mortality and create a PIRO system by binary logistic regression analysis, and the prognostic performance of PIRO was investigated in the validation cohort by receiver operator characteristic (ROC) curve. Ten independent predictors of 28-day mortality were identified. The PIRO system combined the components of predisposition (age, chronic obstructive pulmonary disease, hypoalbuminemia), infection (central nervous system infection), response (temperature, procalcitonin), and organ dysfunction (brain natriuretic peptide, troponin I, mean arterial pressure, Glasgow coma scale score). The area under the ROC of PIRO was 0.833 for the derivation cohort and 0.813 for the validation cohort. There was a stepwise increase in 28-day mortality with increasing PIRO score and the differences between the low- (PIRO 0-10), intermediate- (11-20), and high- (>20) risk groups were very significant in both cohorts (p < 0.01). The present study demonstrates that this PIRO system is valuable for prognosis and risk stratification in patients with CAS in the ED.
Liao, Wen-I; Sheu, Wayne Huey-Herng; Chang, Wei-Chou; Hsu, Chin-Wang; Chen, Yu-Long; Tsai, Shih-Hung
2013-01-01
To assess whether chronic glycemic control and stress-induced hyperglycemia, determined by the gap between admission glucose levels and A1C-derived average glucose (ADAG) levels adversely affects outcomes in diabetic patients with pyogenic liver abscess (PLA). Clinical, laboratory, and multi-detector computed tomography (MDCT) findings of 329 PLA patients (2004-2010) were retrospectively reviewed. HbA1C levels were used to determine long-term glycemic control status, which were then converted to estimated average glucose values. For the gap between admission glucose levels and ADAG levels, we used receiver operating characteristic (ROC) curve to determine the optimal cut-off values predicting adverse outcomes. Univariate and multivariate logistic regressions were used to identify predictors of adverse outcomes. Diabetic PLA patients with poorer glycemic control had significantly higher Klebsiella pneumoniae (KP) infection rates, lower albumin levels, and longer hospital stays than those with suboptimal and good glycemic control. The ROC curve showed that a glycemic gap of 72 mg/dL was the optimal cut-off value for predicting adverse outcomes and showed a 22.3% relative increase in adverse outcomes compared with a glycemic gap<72 mg/dL. Multivariate analysis revealed that an elevated glycemic gap≥72 mg/dL was important predictor of adverse outcomes. A glycemic gap≥72 mg/dL, rather than admission hyperglycemia or chronic glycemic control, was significantly correlated with adverse outcomes in diabetic PLA patients. Poorer chronic glycemic control in diabetic PLA patients is associated with high incidence of KP infection, hypoalbuminemia and longer hospital stay.
Terjung, B; Bogsch, F; Klein, R; Söhne, J; Reichel, C; Wasmuth, J-C; Beuers, U; Sauerbruch, T; Spengler, U
2004-09-29
Antineutrophil cytoplasmic antibodies (atypical p-ANCA) are detected at high prevalence in sera from patients with autoimmune hepatitis (AIH), but their diagnostic relevance for AIH has not been systematically evaluated so far. Here, we studied sera from 357 patients with autoimmune (autoimmune hepatitis n=175, primary sclerosing cholangitis (PSC) n=35, primary biliary cirrhosis n=45), non-autoimmune chronic liver disease (alcoholic liver cirrhosis n=62; chronic hepatitis C virus infection (HCV) n=21) or healthy controls (n=19) for the presence of various non-organ specific autoantibodies. Atypical p-ANCA, antinuclear antibodies (ANA), antibodies against smooth muscles (SMA), antibodies against liver/kidney microsomes (anti-Lkm1) and antimitochondrial antibodies (AMA) were detected by indirect immunofluorescence microscopy, antibodies against the M2 antigen (anti-M2), antibodies against soluble liver antigen (anti-SLA/LP) and anti-Lkm1 by using enzyme linked immunosorbent assays. To define the diagnostic precision of the autoantibodies, results of autoantibody testing were analyzed by receiver operating characteristics (ROC) and forward conditional logistic regression analysis. Atypical p-ANCA were detected at high prevalence in sera from patients with AIH (81%) and PSC (94%). ROC- and logistic regression analysis revealed atypical p-ANCA and SMA, but not ANA as significant diagnostic seromarkers for AIH (atypical p-ANCA: AUC 0.754+/-0.026, odds ratio [OR] 3.4; SMA: 0.652+/-0.028, OR 4.1). Atypical p-ANCA also emerged as the only diagnostically relevant seromarker for PSC (AUC 0.690+/-0.04, OR 3.4). None of the tested antibodies yielded a significant diagnostic accuracy for patients with alcoholic liver cirrhosis, HCV or healthy controls. Atypical p-ANCA along with SMA represent a seromarker with high diagnostic accuracy for AIH and should be explicitly considered in a revised version of the diagnostic score for AIH.
Xu, Minlan; Markström, Urban; Lyu, Juncheng; Xu, Lingzhong
2017-10-04
Depressed patients had risks of non-adherence to medication, which brought a big challenge for the control of tuberculosis (TB). The stigma associated with TB may be the reason for distress. This study aimed to assess the psychological distress among TB patients living in rural areas in China and to further explore the relation of experienced stigma to distress. This study was a cross-sectional study with multi-stage randomized sampling for recruiting TB patients. Data was collected by the use of interviewer-led questionnaires. A total of 342 eligible and accessible TB patients being treated at home were included in the survey. Psychological distress was measured using the Kessler Psychological Distress Scale (K10). Experienced stigma was measured using a developed nine-item stigma questionnaire. Univariate analysis and multiple logistic regression were used to analyze the variables related to distress, respectively. Odds ratios (ORs) and 95% confidence intervals (CIs) were used to present the strength of the associations. Finally, the prediction of logistic model was assessed in form of the Receiver Operating Characteristic (ROC) curve and the area under the ROC curve (AUC). According to the referred cut-off point from K10, this study revealed that 65.2% (223/342) of the participants were categorized as having psychological distress. Both the stigma questionnaire and the K10 were proven to be reliable and valid in measurement. Further analysis found that experienced stigma and illness severity were significant variables to psychological distress in the model of logistic regression. The model was assessed well in predicting distress by use of experienced stigma and illness severity in form of ROC and AUC. Rural TB patients had a high prevalence of psychological distress. Experience of stigma played a significant role in psychological distress. To move the barrier of stigma from the surroundings could be a good strategy in reducing distress for the patients and TB controlling for public health management.
Thompson, Trevor; Lloyd, Andrew; Joseph, Alain; Weiss, Margaret
2017-07-01
The Weiss Functional Impairment Rating Scale-Parent Form (WFIRS-P) is a 50-item scale that assesses functional impairment on six clinically relevant domains typically affected in attention-deficit/hyperactivity disorder (ADHD). As functional impairment is central to ADHD, the WFIRS-P offers potential as a tool for assessing functional impairment in ADHD. These analyses were designed to examine the overall performance of WFIRS-P in differentiating ADHD and non-ADHD cases using receiver operating characteristics (ROC) analysis. This is the first attempt to empirically determine the level of functional impairment that differentiates ADHD children from normal controls. This observational study comprised 5-19-year-olds with physician-diagnosed ADHD (n = 476) and non-ADHD controls (n = 202). ROC analysis evaluated the ability of WFIRS-P to discriminate between ADHD and non-ADHD, and identified a WFIRS-P cut-off score that optimises correct classification. Data were analysed for the complete sample, for males versus females and for participants in two age groups (5-12 versus 13-19 years). Area under the curve (AUC) was 0.91 (95% confidence interval 0.88-0.93) for the overall WFIRS-P score, suggesting highly accurate classification of ADHD distinct from non-ADHD. Sensitivity (0.83) and specificity (0.85) were maximal for a mean overall WFIRS-P score of 0.65, suggesting that this is an appropriate threshold for differentiation. DeLong's test found no significant differences in AUCs for males versus females or 5-12 versus 13-19 years, suggesting that WFIRS-P is an accurate classifier of ADHD across gender and age. When assessing function, WFIRS-P appears to provide a simple and effective basis for differentiating between individuals with/without ADHD in terms of functional impairment. Disease-specific applications of QOL research.
Zhai, Xuetong; Chakraborty, Dev P
2017-06-01
The objective was to design and implement a bivariate extension to the contaminated binormal model (CBM) to fit paired receiver operating characteristic (ROC) datasets-possibly degenerate-with proper ROC curves. Paired datasets yield two correlated ratings per case. Degenerate datasets have no interior operating points and proper ROC curves do not inappropriately cross the chance diagonal. The existing method, developed more than three decades ago utilizes a bivariate extension to the binormal model, implemented in CORROC2 software, which yields improper ROC curves and cannot fit degenerate datasets. CBM can fit proper ROC curves to unpaired (i.e., yielding one rating per case) and degenerate datasets, and there is a clear scientific need to extend it to handle paired datasets. In CBM, nondiseased cases are modeled by a probability density function (pdf) consisting of a unit variance peak centered at zero. Diseased cases are modeled with a mixture distribution whose pdf consists of two unit variance peaks, one centered at positive μ with integrated probability α, the mixing fraction parameter, corresponding to the fraction of diseased cases where the disease was visible to the radiologist, and one centered at zero, with integrated probability (1-α), corresponding to disease that was not visible. It is shown that: (a) for nondiseased cases the bivariate extension is a unit variances bivariate normal distribution centered at (0,0) with a specified correlation ρ 1 ; (b) for diseased cases the bivariate extension is a mixture distribution with four peaks, corresponding to disease not visible in either condition, disease visible in only one condition, contributing two peaks, and disease visible in both conditions. An expression for the likelihood function is derived. A maximum likelihood estimation (MLE) algorithm, CORCBM, was implemented in the R programming language that yields parameter estimates and the covariance matrix of the parameters, and other statistics. A limited simulation validation of the method was performed. CORCBM and CORROC2 were applied to two datasets containing nine readers each contributing paired interpretations. CORCBM successfully fitted the data for all readers, whereas CORROC2 failed to fit a degenerate dataset. All fits were visually reasonable. All CORCBM fits were proper, whereas all CORROC2 fits were improper. CORCBM and CORROC2 were in agreement (a) in declaring only one of the nine readers as having significantly different performances in the two modalities; (b) in estimating higher correlations for diseased cases than for nondiseased ones; and (c) in finding that the intermodality correlation estimates for nondiseased cases were consistent between the two methods. All CORCBM fits yielded higher area under curve (AUC) than the CORROC2 fits, consistent with the fact that a proper ROC model like CORCBM is based on a likelihood-ratio-equivalent decision variable, and consequently yields higher performance than the binormal model-based CORROC2. The method gave satisfactory fits to four simulated datasets. CORCBM is a robust method for fitting paired ROC datasets, always yielding proper ROC curves, and able to fit degenerate datasets. © 2017 American Association of Physicists in Medicine.
Goodman, Corey W; Major, Heather J; Walls, William D; Sheffield, Val C; Casavant, Thomas L; Darbro, Benjamin W
2015-04-01
Chromosomal microarrays (CMAs) are routinely used in both research and clinical laboratories; yet, little attention has been given to the estimation of genome-wide true and false negatives during the assessment of these assays and how such information could be used to calibrate various algorithmic metrics to improve performance. Low-throughput, locus-specific methods such as fluorescence in situ hybridization (FISH), quantitative PCR (qPCR), or multiplex ligation-dependent probe amplification (MLPA) preclude rigorous calibration of various metrics used by copy number variant (CNV) detection algorithms. To aid this task, we have established a comparative methodology, CNV-ROC, which is capable of performing a high throughput, low cost, analysis of CMAs that takes into consideration genome-wide true and false negatives. CNV-ROC uses a higher resolution microarray to confirm calls from a lower resolution microarray and provides for a true measure of genome-wide performance metrics at the resolution offered by microarray testing. CNV-ROC also provides for a very precise comparison of CNV calls between two microarray platforms without the need to establish an arbitrary degree of overlap. Comparison of CNVs across microarrays is done on a per-probe basis and receiver operator characteristic (ROC) analysis is used to calibrate algorithmic metrics, such as log2 ratio threshold, to enhance CNV calling performance. CNV-ROC addresses a critical and consistently overlooked aspect of analytical assessments of genome-wide techniques like CMAs which is the measurement and use of genome-wide true and false negative data for the calculation of performance metrics and comparison of CNV profiles between different microarray experiments. Copyright © 2015 Elsevier Inc. All rights reserved.
Report on carcinogens monograph on cumene.
2013-09-01
The National Toxicology Program conducted a cancer evaluation on cumene for possible listing in the Report on Carcinogens (RoC). The cancer evaluation is captured in the RoC monograph, which was peer reviewed in a public forum. The monograph consists of two components: (Part 1) the cancer evaluation, which reviews the relevant scientific information, assesses its quality, applies the RoC listing criteria to the scientific information, and provides the NTP recommendation for listing status for cumene in the RoC, and (Part 2) the substance profile proposed for the RoC, containing the NTP's listing status recommendation, a summary of the scientific evidence considered key to reaching that decision, and data on properties, use, production, exposure, and Federal regulations and guidelines to reduce exposure to cumene. This monograph provides an assessment of the available scientific information on cumene, including human exposure and properties, disposition and toxicokinetics, cancer studies in experimental animals, and studies of mechanisms and other related effects, including relevant toxicological effects, genetic toxicology, and mechanisms of carcinogenicity. From this assessment, the NTP recommended that cumene be listed as reasonably anticipated to be a human carcinogen in the RoC based on sufficient evidence from studies in experimental animals, which found that cumene exposure caused lung tumors in male and female mice and liver tumors in female mice. Several proposed mechanisms of carcinogenesis support the relevance to humans of the lung and liver tumors observed in experimental animals. Specifically, there is evidence that humans and experimental animals metabolize cumene through similar metabolic pathways. In addition, mutations of the K-ras oncogene and p53 tumor-suppressor gene observed in cumene-induced lung tumors in mice, along with altered expression of many other genes, resemble molecular alterations found in human lung and other cancers.
Report on carcinogens monograph on 1-bromopropane.
2013-09-01
The National Toxicology Program conducted a cancer evaluation on 1 bromopropane for possible listing in the Report on Carcinogens (RoC). The cancer evaluation is captured in the RoC monograph, which was peer reviewed in a public forum. The monograph consists of two components: (Part 1) the cancer evaluation, which reviews the relevant scientific information, assesses its quality, applies the RoC listing criteria to the scientific information, and provides the NTP recommendation for listing status for 1 bromopropane in the RoC, and (Part 2) the substance profile proposed for the RoC, containing the NTP's listing status recommendation, a summary of the scientific evidence considered key to reaching that decision, and data on properties, use, production, exposure, and Federal regulations and guidelines to reduce exposure to 1-bromopropane. This monograph provides an assessment of the available scientific information on 1 bromopropane, including human exposure and properties, disposition and toxicokinetics, cancer studies in experimental animals, and studies of mechanisms and other related effects, including relevant toxicological effects, genetic toxicology, and mechanisms of carcinogenicity. From this assessment, the NTP recommended that 1 bromopropane be listed as reasonably anticipated to be a human carcinogen in the RoC based on sufficient evidence from studies in experimental animals, which found inhalation exposure to 1-bromopropane caused skin tumors in male rats, large intestine tumors in female and male rats, and lung tumors in female mice. Also noted was that 1 bromopropane, either directly or via reactive metabolites, caused molecular alterations that typically are associated with carcinogenesis, including genotoxicity, oxidative stress, and glutathione depletion. These alterations, observed in mainly in vitro and toxicity studies in rodents, are relevant to possible mechanisms of human carcinogenicity and support the relevance of the cancer studies in experimental animals to humans.
Comparison of accelerometer cut points for predicting activity intensity in youth.
Trost, Stewart G; Loprinzi, Paul D; Moore, Rebecca; Pfeiffer, Karin A
2011-07-01
The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and V˙O2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). Across all four intensity levels, the EV (κ=0.68) and FT (κ=0.66) cut points exhibited significantly better agreement than TR (κ=0.62), MT (κ=0.54), and PU (κ=0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate- to vigorous-intensity physical activity (ROC-AUC=0.90) than TR, PU, or MT cut points (ROC-AUC=0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC=0.90). On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents.
Rockall score in predicting outcomes of elderly patients with acute upper gastrointestinal bleeding
Wang, Chang-Yuan; Qin, Jian; Wang, Jing; Sun, Chang-Yi; Cao, Tao; Zhu, Dan-Dan
2013-01-01
AIM: To validate the clinical Rockall score in predicting outcomes (rebleeding, surgery and mortality) in elderly patients with acute upper gastrointestinal bleeding (AUGIB). METHODS: A retrospective analysis was undertaken in 341 patients admitted to the emergency room and Intensive Care Unit of Xuanwu Hospital of Capital Medical University with non-variceal upper gastrointestinal bleeding. The Rockall scores were calculated, and the association between clinical Rockall scores and patient outcomes (rebleeding, surgery and mortality) was assessed. Based on the Rockall scores, patients were divided into three risk categories: low risk ≤ 3, moderate risk 3-4, high risk ≥ 4, and the percentages of rebleeding/death/surgery in each risk category were compared. The area under the receiver operating characteristic (ROC) curve was calculated to assess the validity of the Rockall system in predicting rebleeding, surgery and mortality of patients with AUGIB. RESULTS: A positive linear correlation between clinical Rockall scores and patient outcomes in terms of rebleeding, surgery and mortality was observed (r = 0.962, 0.955 and 0.946, respectively, P = 0.001). High clinical Rockall scores > 3 were associated with adverse outcomes (rebleeding, surgery and death). There was a significant correlation between high Rockall scores and the occurrence of rebleeding, surgery and mortality in the entire patient population (χ2 = 49.29, 23.10 and 27.64, respectively, P = 0.001). For rebleeding, the area under the ROC curve was 0.788 (95%CI: 0.726-0.849, P = 0.001); For surgery, the area under the ROC curve was 0.752 (95%CI: 0.679-0.825, P = 0.001) and for mortality, the area under the ROC curve was 0.787 (95%CI: 0.716-0.859, P = 0.001). CONCLUSION: The Rockall score is clinically useful, rapid and accurate in predicting rebleeding, surgery and mortality outcomes in elderly patients with AUGIB. PMID:23801840
Franz, S; Schuld, C; Wilder-Smith, E P; Heutehaus, L; Lang, S; Gantz, S; Schuh-Hofer, S; Treede, R-D; Bryce, T N; Wang, H; Weidner, N
2017-11-01
Neuropathic pain (NeuP) is a frequent sequel of spinal cord injury (SCI). The SCI Pain Instrument (SCIPI) was developed as a SCI-specific NeuP screening tool. A preliminary validation reported encouraging results requiring further evaluation in terms of psychometric properties. The painDETECT questionnaire (PDQ), a commonly applied NeuP assessment tool, was primarily validated in German, but not specifically developed for SCI and not yet validated according to current diagnostic guidelines. We aimed to provide convergent construct validity and to identify the optimal item combination for the SCIPI. The PDQ was re-evaluated according to current guidelines with respect to SCI-related NeuP. Prospective monocentric study. Subjects received a neurological examination according to the International Standards for Neurological Classification of SCI. After linguistic validation of the SCIPI, the IASP-grading system served as reference to diagnose NeuP, accompanied by the PDQ after its re-evaluation as binary classifier. Statistics were evaluated through ROC-analysis, with the area under the ROC curve (AUROC) as optimality criterion. The SCIPI was refined by systematic item permutation. Eighty-eight individuals were assessed with the German SCIPI. Of 127 possible combinations, a 4-item-SCIPI (cut-off-score = 1.5/sensitivity = 0.864/specificity = 0.839) was identified as most reasonable. The SCIPI showed a strong correlation (r sp = 0.76) with PDQ. ROC-analysis of SCIPI/PDQ (AUROC = 0.877) revealed comparable results to SCIPI/IASP (AUROC = 0.916). ROC-analysis of PDQ/IASP delivered a score threshold of 10.5 (sensitivity = 0.727/specificity = 0.903). The SCIPI is a valid easy-to-apply NeuP screening tool in SCI. The PDQ is recommended as complementary NeuP assessment tool in SCI, e.g. to monitor pain severity and/or its time-dependent course. In SCI-related pain, both SCIPI and PainDETECT show strong convergent construct validity versus the current IASP-grading system. SCIPI is now optimized from a 7-item to an easy-to-apply 4-item screening tool in German and English. We provided evidence that the scope for PainDETECT can be expanded to individuals with SCI. © 2017 European Pain Federation - EFIC®.
Gao, Cheng-Kai; Li, Yan-Fei; Wang, Lu; Han, Xiao-Yan; Wu, Ting; Zeng, Fang-Fang; Li, Xiang-Ping
2018-05-31
To assess the differences in Reflux Finding Score (RFS) between the genders and determine the suitable RFS threshold for diagnosing laryngopharyngeal reflux disease (LPRD) in each gender. Asymptomatic volunteers and patients with LPRD, confirmed with an oropharyngeal Dx-pH monitoring system, were included. All study subjects underwent transnasal flexible fiber-optic video laryngoscopy. Reliability was assessed with intra-class correlation coefficients (ICCs) and Bland-Altman plots. The RFS cutoffs for determining the presence and absence of LPRD between the two genders were examined by receiver operating characteristic (ROC) analysis. One hundred seven asymptomatic volunteers and fifty-five LPRD patients were recruited. The mean RFS for LPRD subjects (9.4 ± 3.2) was significantly higher than that for control subjects (7.1 ± 2.6; p < 0.001). The mean RFS for asymptomatic females (6.1 ± 2.7) was significantly lower than that for males (7.7 ± 2.5; p < 0.001). The mean RFS for female subjects with LPRD (7.8 ± 2.6) was lower than that for males (11.0 ± 2.8; p < 0.001). According to ROC analysis, the best cutoffs were 9.0 for males and 6.0 for females. There was a significant difference in the RFS cutoff between the genders. For male subjects, we recommend a cutoff of 9.0 for diagnosing LPRD, and for female subjects, we recommend a cutoff of 6.0.
Morris, John A; Norris, Patrick R; Ozdas, Asli; Waitman, Lemuel R; Harrell, Frank E; Williams, Anna E; Cao, Hanqing; Jenkins, Judith M
2006-06-01
Measurements of a patient's physiologic reserve (age, injury severity, admission lactic acidosis, transfusion requirements, and coagulopathy) reflect robustness of response to surgical insult. We have previously shown that cardiac uncoupling (reduced heart rate variability, HRV) in the first 24 hours after injury correlates with mortality and autonomic nervous system failure. We hypothesized: Deteriorating physiologic reserve correlates with reduced HRV and cardiac uncoupling. There were 1,425 trauma ICU patients that satisfied the inclusion criteria. Differences in mortality across categorical measurements of the domains of physiologic reserve were assessed using the chi test. The relationship of cardiac uncoupling and physiologic reserve was examined using multivariate logistic regression models for various levels of cardiac uncoupling (>0 through 28% reduced HRV in the first 24 hours). Of these, 797 (55.9%) patients exhibited cardiac uncoupling. Deteriorating measures of physiologic reserve reflected increased risk of death. Measures of acidosis (admission lactate, time to lactate normalization, and lactate deterioration over the first 24 hours), coagulopathy, age, and injury severity contributed significantly to the risk of cardiac uncoupling (area under receiver operator curve, ROC=0.73). The association between deteriorating reserve and cardiac uncoupling increases with the threshold for uncoupling (ROC=0.78). Reduced heart rate variability is a new biomarker reflecting the loss of command and control of the heart (cardiac uncoupling). Risk of cardiac uncoupling increases significantly as a patient's physiologic reserve deteriorates and physiologic exhaustion approaches. Cardiac uncoupling provides a noninvasive, overall measure of a patient's clinical trajectory over the first 24 hours of ICU stay.
2017-06-06
OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for...Geophysical Mapping, Electromagnetic Induction, Instrument Verification Strip, Time Domain Electromagnetic, Unexploded Ordnance 16. SECURITY...Munitions Response QA Quality Assurance QC Quality Control ROC Receiver Operating Characteristic RTK Real- time Kinematic s Second SNR
Bakas, Panagiotis; Simopoulou, Maria; Giner, Maria; Drakakis, Petros; Panagopoulos, Perikles; Vlahos, Nikolaos
2017-10-01
The objective of this study is to assess if the difference of repeated measurements of estradiol and progesterone during luteal phase predict the outcome of intrauterine insemination. Prospective study. Reproductive clinic. 126 patients with infertility. Patients underwent controlled ovarian stimulation with recombinant FSH (50-150 IU/d). The day of IUI patients were given p.o natural micronized progesterone in a dose of 100 mg/tds. The area under the receiver characteristic operating curve (ROC curve) in predicting clinical pregnancy for % change of estradiol level on days 6 and 10 was 0.892 with 95% CI: 0.82-0.94. A cutoff value of change > -29.5% had a sensitivity of 85.7 with a specificity of 90.2. The corresponding ROC curve for % change of progesterone level was 0.839 with 95% CI: 0.76-0.90. A cutoff value of change > -33% had a sensitivity of 85 with a specificity of 75. The % change of estradiol and progesterone between days 6 and 10 has a predictive ability of pregnancy after IUI with COS of 89.2% and 83.4%, respectively. The addition of % of progesterone to % change of estradiol does not improve the predictive ability of % estradiol and should not be used.
Haran, F Jay; Dretsch, Michael N; Slaboda, Jill C; Johnson, Dagny E; Adam, Octavian R; Tsao, Jack W
2016-01-01
To examine differences between the baseline-referenced and norm-referenced approaches for determining decrements in Automated Neuropsychological Assessment Metrics Version 4 TBI-MIL (ANAM) performance following mild traumatic brain injury (mTBI). ANAM data were reviewed for 616 US Service members, with 528 of this sample having experienced an mTBI and 88 were controls. Post-injury change scores were calculated for each sub-test: (1) normative change score = in-theater score - normative mean and (2) baseline change score = in-theater score - pre-deployment baseline. Reliable change cut-scores were applied to the change and the resulting frequency distributions were compared using McNemar tests. Receiver operator curves (ROC) using both samples (i.e. mTBI and control) were calculated for the change scores for each approach to determine the discriminate ability of the ANAM. There were no statistical differences, p < 0.05 (Bonferonni-Holm corrected), between the approaches. When the area under the curve for the ROCs were averaged across sub-tests, there were no significant differences between either the norm-referenced (0.65) or baseline-referenced (0.66) approaches, p > 0.05. Overall, the findings suggest there is no clear advantage of using the baseline-referenced approach over norm-referenced approach.
Assessment of Diagnostic and Prognostic Role of Copeptin in the Clinical Setting of Sepsis.
Battista, Stefania; Audisio, Umberto; Galluzzo, Claudia; Maggiorotto, Matteo; Masoero, Monica; Forno, Daniela; Pizzolato, Elisa; Ulla, Marco; Lucchiari, Manuela; Vitale, Annarita; Moiraghi, Corrado; Lupia, Enrico; Settanni, Fabio; Mengozzi, Giulio
2016-01-01
The diagnostic and prognostic usefulness of copeptin were evaluated in septic patients, as compared to procalcitonin assessment. In this single centre and observational study 105 patients were enrolled: 24 with sepsis, 25 with severe sepsis, 15 with septic shock, and 41 controls, divided in two subgroups (15 patients with gastrointestinal bleeding and 26 with suspected SIRS secondary to trauma, acute coronary syndrome, and pulmonary embolism). Biomarkers were determined at the first medical evaluation and thereafter 24, 48, and 72 hours after admission. Definitive diagnosis and in-hospital survival rates at 30 days were obtained through analysis of medical records. At entry, copeptin proved to be able to distinguish cases from controls and also sepsis group from septic shock group, while procalcitonin could distinguish also severe sepsis from septic shock group. Areas under the ROC curve for copeptin and procalcitonin were 0.845 and 0.861, respectively. Noteworthy, patients with copeptin concentrations higher than the threshold value (23.2 pmol/L), calculated from the ROC curve, at admission presented higher 30-day mortality. No significant differences were found in copeptin temporal profile among different subgroups. Copeptin showed promising diagnostic and prognostic role in the management of sepsis, together with its possible role in monitoring the response to treatment.
Assessment of Diagnostic and Prognostic Role of Copeptin in the Clinical Setting of Sepsis
Battista, Stefania; Audisio, Umberto; Galluzzo, Claudia; Maggiorotto, Matteo; Masoero, Monica; Forno, Daniela; Pizzolato, Elisa; Ulla, Marco; Lucchiari, Manuela; Vitale, Annarita; Moiraghi, Corrado; Lupia, Enrico; Settanni, Fabio; Mengozzi, Giulio
2016-01-01
The diagnostic and prognostic usefulness of copeptin were evaluated in septic patients, as compared to procalcitonin assessment. In this single centre and observational study 105 patients were enrolled: 24 with sepsis, 25 with severe sepsis, 15 with septic shock, and 41 controls, divided in two subgroups (15 patients with gastrointestinal bleeding and 26 with suspected SIRS secondary to trauma, acute coronary syndrome, and pulmonary embolism). Biomarkers were determined at the first medical evaluation and thereafter 24, 48, and 72 hours after admission. Definitive diagnosis and in-hospital survival rates at 30 days were obtained through analysis of medical records. At entry, copeptin proved to be able to distinguish cases from controls and also sepsis group from septic shock group, while procalcitonin could distinguish also severe sepsis from septic shock group. Areas under the ROC curve for copeptin and procalcitonin were 0.845 and 0.861, respectively. Noteworthy, patients with copeptin concentrations higher than the threshold value (23.2 pmol/L), calculated from the ROC curve, at admission presented higher 30-day mortality. No significant differences were found in copeptin temporal profile among different subgroups. Copeptin showed promising diagnostic and prognostic role in the management of sepsis, together with its possible role in monitoring the response to treatment. PMID:27366743
Nolfe, Giovanni; Petrella, Claudio; Triassi, Maria; Zontini, Gemma; Uttieri, Simona; Pagliaro, Alessia; Blasi, Francesco; Cappuccio, Antonella; Nolfe, Giuseppe
2013-01-01
The aim of this study is to produce preliminary data about the validation of the "Naples-Questionnaire of Distress at Work" (nQ.DW). This inventory is a new assessment tool in order to evaluate the distress perceived in the working environment by means of the differentiation of the conditions linked to the mobbing from which related to organizational disfunction. The nQ-DW also measures the bio-psycho-social global effects of these two phenomena. The questionnaire has been administered to workers suffering of a psychopathological disturbance related to work distress and to a control group matched for the sociodemographic and working variables. The statistical analysis demonstrated a significant validity and reliability. The degree of internal coherence was satisfactory. The ROC curves allow the determination of a threshold value which allows to separate the workers subjected to mobbing and/or organizational stress from control-workers with an optimal reliability degree. The values of the area under the ROC curves show that the inventory has a high discriminating capacity. Future studies, based on a greater sample size, will be oriented to the analysis of the questionnaire by means of multivariate techniques like the factorial analysis.
Increased Levels of Circulating Anti-ANXA1 IgG Antibody in Patients with Non-Small Cell Lung Cancer.
Liang, Tingting; Han, Zhifeng; Zhao, Huan; Zhang, Xuan; Wang, Yao
2018-06-01
Our previous studies revealed that concentrations of circulating antibodies to annexin A1 (ANXA1) were increased in non-small lung cancer (NSCLC). This study was thus designed to replicate this initial finding with an independent sample set. An enzyme-linked immunosorbent assay (ELISA) was developed in-house to examine plasma antiANXA1 IgG levels in 220 patients with NSCLC and 200 control subjects. Mann-Whitney U test showed that patients with NSCLC had significantly higher anti-ANXA1 IgG levels than control subjects (Z = -4.02, p < 0.001); male patients appeared to mainly contribute to the increased antibody level (Z = -3.09, p = 0.002). Receiver operating characteristic (ROC) curve analysis showed an overall area under the ROC curve (AUC) of 0.61 (95% CI: 0.56 - 0.67), with sensitivity of 8% against a specificity of 95.0%. Spearman's correlation analysis failed to show a significant correlation between the anti-ANXA1 IgG levels and the expression of three tumor-associated antigens including p53 (r = 0.156, p = 0.027), Ki67 (r = -0.048, p = 0.489), and EGFR (r = 0.02, p = 0.782). Increased levels of circulating anti-ANXA1 IgG antibody may have a prognostic value for NSCLC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonzalez, P; Olaciregui-Ruiz, I; Mijnheer, B
2016-06-15
Purpose: To investigate the sensitivity of an EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. Methods: For this study 41 EPID-reconstructed 3D in vivo dose distributions of 15 different VMAT plans (H&N, lung, prostate and rectum) were selected. To simulate the effect of delivery errors, their TPS plans were modified by: 1) scaling of the monitor units by ±3% and ±6% and 2) systematic shifting of leaf bank positions by ±1mm, ±2mm and ±5mm. The 3D in vivo dose distributions where then compared to the unmodified and modified treatment plans. To determine the detectability of themore » various delivery errors, we made use of a receiver operator characteristic (ROC) methodology. True positive and false positive rates were calculated as a function of the γ-parameters γmean, γ1% (near-maximum γ) and the PTV dose parameter ΔD{sub 50} (i.e. D{sub 50}(EPID)-D{sub 50}(TPS)). The ROC curve is constructed by plotting the true positive rate vs. the false positive rate. The area under the ROC curve (AUC) then serves as a measure of the performance of the EPID dosimetry system in detecting a particular error; an ideal system has AUC=1. Results: The AUC ranges for the machine output errors and systematic leaf position errors were [0.64 – 0.93] and [0.48 – 0.92] respectively using γmean, [0.57 – 0.79] and [0.46 – 0.85] using γ1% and [0.61 – 0.77] and [ 0.48 – 0.62] using ΔD{sub 50}. Conclusion: For the verification of VMAT deliveries, the parameter γmean is the best discriminator for the detection of systematic leaf position errors and monitor unit scaling errors. Compared to γmean and γ1%, the parameter ΔD{sub 50} performs worse as a discriminator in all cases.« less
Stephens, Shannon W; Williams, Carolyn; Gray, Randal; Kerby, Jeffrey D; Wang, Henry E; Bosarge, Patrick L
2016-06-01
The US Food and Drug Administration and the Department of Health and Human Services outline regulations allowing an exception from informed consent (EFIC) for research conducted in an emergency setting. Acute care clinical trials using EFIC must include community consultation and public disclosure (CC/PD) activities. We describe our experience using social media to facilitate the CC/PD process in two trauma resuscitation clinical trials. We conducted local CC/PD activities for two multicenter trauma clinical trials, Pragmatic, Randomized Optimal Platelet and Plasma Ratios (PROPPR) and Prehospital Tranexamic Acid Use for Traumatic Brain Injury (ROC-TXA). As part of the CC/PD process, we developed research study advertisements using the social media Web site Facebook. The Facebook advertisements directed users to a regional study Web site that contained trial information. We targeted the advertisements to specific demographic users, in specific geographic areas. We analyzed the data using descriptive statistics. During the study periods, the PROPPR Facebook advertisement was displayed 5,001,520 times (12 displays per target population) with 374 individuals selecting the advertisement. The ROC-TXA Facebook advertisement was displayed 3,806,448 times (8 per target population) with 790 individuals selecting the advertisement. Respondents to both Facebook advertisements were mostly male (52.6%), with the highest proportion between the ages 15 years and 24 years (28.2%). Collectively, 26.9% of individuals that clicked on the Facebook advertisement spent more than 3 minutes on the study Web site (3-49 minutes). Commonly accessed Web pages were "contact us" (PROPPR, 5.5%; ROC-TXA, 7.7%), "study-specific FAQs" (PROPPR, 2.4%; ROC-TXA, 6.7%), and "opt out of research" (PROPPR, 2.5%; ROC-TXA, 3.8%). Of 51 total individuals viewing the opt out of research information (PROPPR, 19; ROC-TXA, 32), time spent on that specific page was modest (PROPPR, 62 seconds; ROC-TXA, 55 seconds), with no individuals requesting to opt out of either study participation. In clinical trauma trials using EFIC, social media may provide a viable option for facilitating the CC/PD process.
Urinary Angiotensinogen and Renin Excretion are Associated with Chronic Kidney Disease.
Juretzko, Annett; Steinbach, Antje; Hannemann, Anke; Endlich, Karlhans; Endlich, Nicole; Friedrich, Nele; Lendeckel, Uwe; Stracke, Sylvia; Rettig, Rainer
2017-01-01
Several studies sought to identify new biomarkers for chronic kidney disease (CKD). As the renal renin-angiotensin system is activated in CKD, urinary angiotensinogen or renin excretion may be suitable candidates. We tested whether urinary angiotensinogen or renin excretion is elevated in CKD and whether these parameters are associated with estimated glomerular filtration rate (eGFR). We further tested whether urinary angiotensinogen or renin excretion may convey additional information beyond that provided by albuminuria. We measured urinary and plasma angiotensinogen, renin, albumin and creatinine in 177 CKD patients from the Greifswald Approach to Individualized Medicine project and in 283 healthy controls from the Study of Health in Pomerania. The urinary excretion of specific proteins is given as protein-to-creatinine ratio. Receiver operating characteristic (ROC) curves, spearman correlation coefficients and linear regression models were calculated. Urinary angiotensinogen [2,511 (196-31,909) vs. 18.6 (8.3-44.0) pmol/g, *P<0.01] and renin excretion [0.311 (0.135-1.155) vs. 0.069 (0.045-0.148) pmol/g, *P<0.01] were significantly higher in CKD patients than in healthy controls. The area under the ROC curve was significantly larger when urinary angiotensinogen, renin and albumin excretion were combined than with urinary albumin excretion alone. Urinary angiotensinogen (ß-coefficient -2.405, standard error 0.117, P<0.01) and renin excretion (ß-coefficient -0.793, standard error 0.061, P<0.01) were inversely associated with eGFR. Adjustment for albuminuria, age, sex, systolic blood pressure and body mass index did not significantly affect the results. Urinary angiotensinogen and renin excretion are elevated in CKD patients. Both parameters are negatively associated with eGFR and these associations are independent of urinary albumin excretion. In CKD patients urinary angiotensinogen and renin excretion may convey additional information beyond that provided by albuminuria. © 2017 The Author(s)Published by S. Karger AG, Basel.
Serum uric acid levels are associated with lupus nephritis in patients with normal renal function.
Calich, Ana Luisa; Borba, Eduardo Ferreira; Ugolini-Lopes, Michelle Remião; da Rocha, Luiza Fuoco; Bonfá, Eloisa; Fuller, Ricardo
2018-05-01
Uric acid has been recognised as a potential marker of endothelial dysfunction and kidney disease but there are scarce data about its importance in systemic lupus erythematosus (SLE) nephritis. This study aimed to evaluate serum uric acid (UA) levels in lupus nephritis (LN), by comparing SLE patients with normal renal function, with and without nephritis. Forty-six female SLE patients were consecutively selected and divided in two groups according to renal activity at the evaluation: presence of a recently diagnosed lupus nephritis (LN+, n = 18) and absence of lupus nephritis (LN-, n = 28). Age-matched healthy women were selected (CONTROL, n = 28). Patients with gout, creatinine clearance lower than 80 ml/min and use of drugs that interfere in UA were excluded. Laboratory and clinical data were analysed by appropriate tests. A multivariate analysis was performed, and a receiver operating characteristic (ROC) curve was plotted, and the area under the curve was calculated to assess the diagnostic strength of UA in LN. The mean age was similar among LN+, LN- and CONTROL groups (32.44 ± 6.09 vs. 30.68 ± 5.36 vs. 30.86 ± 5.00 years, p = 0.52). UA was significantly higher in LN+ compared to LN- (5.54 ± 1.67 vs. 3.65 ± 1.090 mg/dL, p < 0.001) and CONTROL (5.54 ± 1.67 vs. 3.92 ± 0.95 mg/dL p < 0.001). Multivariate analysis confirmed that high UA was an independent variable related to LN (p < 0.001). The cut-off value for UA using the ROC curve was 4.47 mg/dL (AUC 0.86, p = 0.00004, CI 95% 0.75-0.96). Lupus nephritis was associated with higher UA. Hyperuricemia as a predictor of renal damage in SLE needs to be evaluated in further studies.
Automated gait and balance parameters diagnose and correlate with severity in Parkinson disease.
Dewey, D Campbell; Miocinovic, Svjetlana; Bernstein, Ira; Khemani, Pravin; Dewey, Richard B; Querry, Ross; Chitnis, Shilpa; Dewey, Richard B
2014-10-15
To assess the suitability of instrumented gait and balance measures for diagnosis and estimation of disease severity in PD. Each subject performed iTUG (instrumented Timed-Up-and-Go) and iSway (instrumented Sway) using the APDM(®) Mobility Lab. MDS-UPDRS parts II and III, a postural instability and gait disorder (PIGD) score, the mobility subscale of the PDQ-39, and Hoehn & Yahr stage were measured in the PD cohort. Two sets of gait and balance variables were defined by high correlation with diagnosis or disease severity and were evaluated using multiple linear and logistic regressions, ROC analyses, and t-tests. 135 PD subjects and 66 age-matched controls were evaluated in this prospective cohort study. We found that both iTUG and iSway variables differentiated PD subjects from controls (area under the ROC curve was 0.82 and 0.75 respectively) and correlated with all PD severity measures (R(2) ranging from 0.18 to 0.61). Objective exam-based scores correlated more strongly with iTUG than iSway. The chosen set of iTUG variables was abnormal in very mild disease. Age and gender influenced gait and balance parameters and were therefore controlled in all analyses. Our study identified sets of iTUG and iSway variables which correlate with PD severity measures and differentiate PD subjects from controls. These gait and balance measures could potentially serve as markers of PD progression and are under evaluation for this purpose in the ongoing NIH Parkinson Disease Biomarker Program. Copyright © 2014 Elsevier B.V. All rights reserved.
Automated Gait and Balance Parameters Diagnose and Correlate with Severity in Parkinson Disease
Dewey, Daniel C.; Miocinovic, Svjetlana; Bernstein, Ira; Khemani, Pravin; Dewey, Richard B.; Querry, Ross; Chitnis, Shilpa; Dewey, Richard B.
2014-01-01
Objective To assess the suitability of instrumented gait and balance measures for diagnosis and estimation of disease severity in PD. Methods Each subject performed iTUG (instrumented Timed-Up-and-Go) and iSway (instrumented Sway) using the APDM® Mobility Lab. MDS-UPDRS parts II and III, a postural instability and gait disorder (PIGD) score, the mobility subscale of the PDQ-39, and Hoehn & Yahr stage were measured in the PD cohort. Two sets of gait and balance variables were defined by high correlation with diagnosis or disease severity and were evaluated using multiple linear and logistic regressions, ROC analyses, and t-tests. Results 135 PD subjects and 66 age-matched controls were evaluated in this prospective cohort study. We found that both iTUG and iSway variables differentiated PD subjects from controls (area under the ROC curve was 0.82 and 0.75 respectively) and correlated with all PD severity measures (R2 ranging from 0.18 to 0.61). Objective exam-based scores correlated more strongly with iTUG than iSway. The chosen set of iTUG variables was abnormal in very mild disease. Age and gender influenced gait and balance parameters and were therefore controlled in all analyses. Interpretation Our study identified sets of iTUG and iSway variables which correlate with PD severity measures and differentiate PD subjects from controls. These gait and balance measures could potentially serve as markers of PD progression and are under evaluation for this purpose in the ongoing NIH Parkinson Disease Biomarker Program. PMID:25082782
Edwards, Darrin C.; Metz, Charles E.
2012-01-01
Although a fully general extension of ROC analysis to classification tasks with more than two classes has yet to be developed, the potential benefits to be gained from a practical performance evaluation methodology for classification tasks with three classes have motivated a number of research groups to propose methods based on constrained or simplified observer or data models. Here we consider an ideal observer in a task with underlying data drawn from three univariate normal distributions. We investigate the behavior of the resulting ideal observer’s decision variables and ROC surface. In particular, we show that the pair of ideal observer decision variables is constrained to a parametric curve in two-dimensional likelihood ratio space, and that the decision boundary line segments used by the ideal observer can intersect this curve in at most six places. From this, we further show that the resulting ROC surface has at most four degrees of freedom at any point, and not the five that would be required, in general, for a surface in a six-dimensional space to be non-degenerate. In light of the difficulties we have previously pointed out in generalizing the well-known area under the ROC curve performance metric to tasks with three or more classes, the problem of developing a suitable and fully general performance metric for classification tasks with three or more classes remains unsolved. PMID:23162165
Kairisto, V; Poola, A
1995-01-01
GraphROC for Windows is a program for clinical test evaluation. It was designed for the handling of large datasets obtained from clinical laboratory databases. In the user interface, graphical and numerical presentations are combined. For simplicity, numerical data is not shown unless requested. Relevant numbers can be "picked up" from the graph by simple mouse operations. Reference distributions can be displayed by using automatically optimized bin widths. Any percentile of the distribution with corresponding confidence limits can be chosen for display. In sensitivity-specificity analysis, both illness- and health-related distributions are shown in the same graph. The following data for any cutoff limit can be shown in a separate click window: clinical sensitivity and specificity with corresponding confidence limits, positive and negative likelihood ratios, positive and negative predictive values and efficiency. Predictive values and clinical efficiency of the cutoff limit can be updated for any prior probability of disease. Receiver Operating Characteristics (ROC) curves can be generated and combined into the same graph for comparison of several different tests. The area under the curve with corresponding confidence interval is calculated for each ROC curve. Numerical results of analyses and graphs can be printed or exported to other Microsoft Windows programs. GraphROC for Windows also employs a new method, developed by us, for the indirect estimation of health-related limits and change limits from mixed distributions of clinical laboratory data.
A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric
2010-10-01
steps applied for generating the 3D ROC surface diagnostic metrics: 1. Obtain system data: Gain access to a suitable database of system data under...surface, VUSTPR and VUSCCR, can be calculated. This can be accomplished by partitioning the VUSTPR and VUSCCR volumes into polyhedrons as illustrated... polyhedron volumes to produce VUSTPR and VUSCCR. In the example given in Figures 7 and 8 a logarithmic scaling has been applied to the TL axis. This places
Sun, Haitao; Liu, Kai; Liu, Hao; Ji, Zongfei; Yan, Yan; Jiang, Lindi; Zhou, Jianjun
2018-04-01
Background There has been a growing need for a sensitive and effective imaging method for the differentiation of the activity of ankylosing spondylitis (AS). Purpose To compare the performances of intravoxel incoherent motion (IVIM)-derived parameters and the apparent diffusion coefficient (ADC) for distinguishing AS-activity. Material and Methods One hundred patients with AS were divided into active (n = 51) and non-active groups (n = 49) and 21 healthy volunteers were included as control. The ADC, diffusion coefficient ( D), pseudodiffusion coefficient ( D*), and perfusion fraction ( f) were calculated for all groups. Kruskal-Wallis tests and receiver operator characteristic (ROC) curve analysis were performed for all parameters. Results There was good reproducibility of ADC /D and relatively poor reproducibility of D*/f. ADC, D, and f were significantly higher in the active group than in the non-active and control groups (all P < 0.0001, respectively). D* was slightly but significant lower in the active group than in the non-active and control group ( P = 0.0064, 0.0215). There was no significant difference in any parameter between the non-active group and the control group (all P > 0.050). In the ROC analysis, ADC had the largest AUC for distinguishing between the active group and the non-active group (0.988) and between the active and control groups (0.990). Multivariate logistic regression analysis models showed no diagnostic improvement. Conclusion ADC provided better diagnostic performance than IVIM-derived parameters in differentiating AS activity. Therefore, a straightforward and effective mono-exponential model of diffusion-weighted imaging may be sufficient for differentiating AS activity in the clinic.
[Role of serum 25-hydroxyvitamin D in the diagnosis of vitamin D deficiency rickets].
Wang, Xiao-Yan; Jin, Chun-Hua; Wu, Jian-Xin; Liu, Zhuo; Li, Mei; Li, Na
2012-10-01
To study the role of serum 25-hydroxyvitamin D in the early diagnosis of vitamin D deficiency rickets. Concentrations of serum 25(OH)D, calcium, phosphorus and alkaline phosphatase were measured in normal control (n=73), suspected rickets (n=45) and confirmed rickets groups (n=65). Receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of serum 25(OH)D for rickets. Serum 25(OH)D levels in the suspected and confirmed rickets groups were 83±30 and 72±31 nmol/L respectively, which was lower than in the normal control group (112±37 nmol/L) (P<0.01). There was no significant difference between the suspected and confirmed rickets groups (P>0.05). Vitamin D deficiency rates in the suspected and confirmed rickets groups were higher than in the control group (P<0.01). The ROC curve area of serum 25(OH)D for the diagnosis of rickets was 0.760 (95%CI 0.692-0.820, P<0.01), and the optimal operating point was 90.70 nmol/L (sensitivity 68.49%, specificity 72.73%). There was no significant difference in levels of calcium, phosphorus and alkaline phosphatase between the three groups (P>0.05). Serum 25(OH)D levels in infants with suspected and confirmed rickets are significantly reduced and this may reflect vitamin D deficiency . Therefore, it may be useful to check serum 25(OH)D levels in screening for rickets.
Oguz, Cihan; Sen, Shurjo K; Davis, Adam R; Fu, Yi-Ping; O'Donnell, Christopher J; Gibbons, Gary H
2017-10-26
One goal of personalized medicine is leveraging the emerging tools of data science to guide medical decision-making. Achieving this using disparate data sources is most daunting for polygenic traits. To this end, we employed random forests (RFs) and neural networks (NNs) for predictive modeling of coronary artery calcium (CAC), which is an intermediate endo-phenotype of coronary artery disease (CAD). Model inputs were derived from advanced cases in the ClinSeq®; discovery cohort (n=16) and the FHS replication cohort (n=36) from 89 th -99 th CAC score percentile range, and age-matched controls (ClinSeq®; n=16, FHS n=36) with no detectable CAC (all subjects were Caucasian males). These inputs included clinical variables and genotypes of 56 single nucleotide polymorphisms (SNPs) ranked highest in terms of their nominal correlation with the advanced CAC state in the discovery cohort. Predictive performance was assessed by computing the areas under receiver operating characteristic curves (ROC-AUC). RF models trained and tested with clinical variables generated ROC-AUC values of 0.69 and 0.61 in the discovery and replication cohorts, respectively. In contrast, in both cohorts, the set of SNPs derived from the discovery cohort were highly predictive (ROC-AUC ≥0.85) with no significant change in predictive performance upon integration of clinical and genotype variables. Using the 21 SNPs that produced optimal predictive performance in both cohorts, we developed NN models trained with ClinSeq®; data and tested with FHS data and obtained high predictive accuracy (ROC-AUC=0.80-0.85) with several topologies. Several CAD and "vascular aging" related biological processes were enriched in the network of genes constructed from the predictive SNPs. We identified a molecular network predictive of advanced coronary calcium using genotype data from ClinSeq®; and FHS cohorts. Our results illustrate that machine learning tools, which utilize complex interactions between disease predictors intrinsic to the pathogenesis of polygenic disorders, hold promise for deriving predictive disease models and networks.
Zhao, Lijuan; Whan, Xiaozeng; Wang, Shouyu; Liu, Hongxiang; Li, Haibo; Miao, Shujie; Ang, Feng
2006-05-01
A long-term experiment was conducted on a black soil of Northeast China to study the effects of applying chemical fertilizers and recycled organic manure (ROM) on the changes of soil organic carbon and its fractions. The results showed that from 1985 to 2004, soil total organic carbon (TOC) decreased by 7.83% in control,4.56% in N application, 1.61% in N + P application, and 5.56% in ROM application, but increased by 0.33% in N + P + K application. Comparing with single application of ROM, its application with chemical fertilizers, i. e., N + ROM, N + P + ROM, and N + P + K + ROM, increased the TOC concentration by 0.35%, 1.05% and 0.64%, respectively. The readily oxidized carbon (ROC) in fertilization treatments was increased by 8.64% to approximately 28.4%, and the increment was higher in treatments of chemical fertilizers plus ROM than in treatments of chemical fertilizers. The ROC was significantly correlated with soil TOC (Y = 14.192X + 23.9, R2 = 0.802) and stalk yields (Y = 19032X - 7950.6, R2 = 0.759). Light fraction organic carbon (LF-C) had the same trends with ROC. After 20 years fertilization, the organic carbon in soil humic acid and fulvic acid was decreased by 1.64% to approximately 26.23% and 2.33% to approximately 28.68%, respectively, but in treatments of chemical fertilizers plus ROM, the decreasing trend was slowed down.
Predictive value of ADAMTS-13 on concealed chronic renal failure in COPD patients
Zeng, Mian; Chen, Qingui; Liang, Wenjie; He, Wanmei; Zheng, Haichong; Huang, Chunrong
2017-01-01
Background Impaired renal function is often neglected in COPD patients. Considering that COPD patients usually have an ongoing prothrombotic state and systemic inflammation status, we investigated the association among them and explored the predictive value of a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13 (ADAMTS-13), on concealed chronic renal failure (CRF) in COPD patients. Methods COPD patients were recruited from the First Affiliated Hospital of Sun Yat-Sen University between January 2015 and December 2016. Control was selected from contemporaneous hospitalized patients without COPD and matched by age and gender at a ratio of 1:1. Estimated glomerular filtration rate (eGFR) was calculated by using the Chronic Kidney Disease Epidemiology Collaboration formula, and all subjects were categorized as having normal renal function (eGFR ≥60 mL min−1 1.73 m−2) and having concealed CRF (normal serum creatinine while eGFR <60 mL min−1 1.73 m−2). Independent correlates of concealed CRF were investigated by logistic regression analysis, and receiver operating characteristic (ROC) curves were used to determine the predictive value of ADAMTS-13. Results In total, 106 COPD and 106 non-COPD patients were finally recruited, and the incidences of concealed CRF were 19.81% and 7.55%, respectively. ADAMTS-13 (odds ratio [OR] =0.858, 95% CI =0.795–0.926), D-dimer (OR =1.095, 95% CI =1.027–1.169), and C-reactive protein (OR =1.252, 95% CI =1.058–1.480) were significantly associated with concealed CRF. Sensitivity and specificity at an ADAMTS-13 cutoff of 318.72 ng/mL were 100% and 81.2%, respectively. The area under the ROC curve was 0.959. Conclusion Prothrombotic state and systemic inflammation status might contribute to explaining the high incidence of concealed CRF in COPD, and plasma ADAMTS-13 levels may serve as a strong predictor. PMID:29255356
Tal, Reshef; Seifer, David B; Wantman, Ethan; Baker, Valerie; Tal, Oded
2018-02-01
To determine if serum antimüllerian hormone (AMH) is associated with and/or predictive of live birth assisted reproductive technology (ART) outcomes. Retrospective analysis of Society for Assisted Reproductive Technology Clinic Outcome Reporting System database from 2012 to 2013. Not applicable. A total of 69,336 (81.8%) fresh and 15,458 (18.2%) frozen embryo transfer (FET) cycles with AMH values. None. Live birth. A total of 85,062 out of 259,499 (32.7%) fresh and frozen-thawed autologous non-preimplantation genetic diagnosis cycles had AMH reported for cycles over this 2-year period. Of those, 70,565 cycles which had embryo transfers were included in the analysis. Serum AMH was significantly associated with live birth outcome per transfer in both fresh and FET cycles. Multiple logistic regression demonstrated that AMH is an independent predictor of live birth in fresh transfer cycles and FET cycles when controlling for age, body mass index, race, day of transfer, and number of embryos transferred. Receiver operating characteristic (ROC) curves demonstrated that the areas under the curve (AUC) for AMH as predictors of live birth in fresh cycles and thawed cycles were 0.631 and 0.540, respectively, suggesting that AMH alone is a weak independent predictor of live birth after ART. Similar ROC curves were obtained also when elective single-embryo transfer (eSET) cycles were analyzed separately in either fresh (AUC 0.655) or FET (AUC 0.533) cycles, although AMH was not found to be an independent predictor in eSET cycles. AMH is a poor independent predictor of live birth outcome in either fresh or frozen embryo transfer for both eSET and non-SET transfers. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
A ROC-based feature selection method for computer-aided detection and diagnosis
NASA Astrophysics Data System (ADS)
Wang, Songyuan; Zhang, Guopeng; Liao, Qimei; Zhang, Junying; Jiao, Chun; Lu, Hongbing
2014-03-01
Image-based computer-aided detection and diagnosis (CAD) has been a very active research topic aiming to assist physicians to detect lesions and distinguish them from benign to malignant. However, the datasets fed into a classifier usually suffer from small number of samples, as well as significantly less samples available in one class (have a disease) than the other, resulting in the classifier's suboptimal performance. How to identifying the most characterizing features of the observed data for lesion detection is critical to improve the sensitivity and minimize false positives of a CAD system. In this study, we propose a novel feature selection method mR-FAST that combines the minimal-redundancymaximal relevance (mRMR) framework with a selection metric FAST (feature assessment by sliding thresholds) based on the area under a ROC curve (AUC) generated on optimal simple linear discriminants. With three feature datasets extracted from CAD systems for colon polyps and bladder cancer, we show that the space of candidate features selected by mR-FAST is more characterizing for lesion detection with higher AUC, enabling to find a compact subset of superior features at low cost.
Impact of signal scattering and parametric uncertainties on receiver operating characteristics
NASA Astrophysics Data System (ADS)
Wilson, D. Keith; Breton, Daniel J.; Hart, Carl R.; Pettit, Chris L.
2017-05-01
The receiver operating characteristic (ROC curve), which is a plot of the probability of detection as a function of the probability of false alarm, plays a key role in the classical analysis of detector performance. However, meaningful characterization of the ROC curve is challenging when practically important complications such as variations in source emissions, environmental impacts on the signal propagation, uncertainties in the sensor response, and multiple sources of interference are considered. In this paper, a relatively simple but realistic model for scattered signals is employed to explore how parametric uncertainties impact the ROC curve. In particular, we show that parametric uncertainties in the mean signal and noise power substantially raise the tails of the distributions; since receiver operation with a very low probability of false alarm and a high probability of detection is normally desired, these tails lead to severely degraded performance. Because full a priori knowledge of such parametric uncertainties is rarely available in practice, analyses must typically be based on a finite sample of environmental states, which only partially characterize the range of parameter variations. We show how this effect can lead to misleading assessments of system performance. For the cases considered, approximately 64 or more statistically independent samples of the uncertain parameters are needed to accurately predict the probabilities of detection and false alarm. A connection is also described between selection of suitable distributions for the uncertain parameters, and Bayesian adaptive methods for inferring the parameters.
Automated analysis of heidelberg retina tomograph optic disc images by glaucoma probability score.
Coops, Annemiek; Henson, David Barry; Kwartz, Anna J; Artes, Paul Habib
2006-12-01
To compare the diagnostic performance of the Heidelberg Retinal Tomograph's (HRT; Heidelberg Engineering GmbH, Dossenheim, Germany) glaucoma probability score (GPS), an automated, contour line-independent method of optic disc analysis with that of the Moorfields regression analysis (MRA). HRT images were obtained from one eye of 121 patients with glaucoma (median age, 70.2 years; median mean deviation [MD], -3.6 dB, range, +2.0 to -9.9 dB) and 95 healthy control subjects (median age, 59.7 years; median MD -0.1 dB, range +2.5 to -3.7). The diagnostic performances of GPS and MRA were evaluated by including borderline classifications, either as test negatives (most specific criteria) or as test positives (least specific criteria). Agreement between global and sectoral data of both analyses was established. Logistic regression analyses were performed to evaluate the effect of covariates such as optic disc size and age on the classification outcomes of both the GPS and the MRA. In 8 (7%) patients with glaucoma and 10 (11%) control subjects, the GPS failed to provide a complete global and sectoral optic disc classification. Although we could not identify a single distinct cause of this failure in the glaucoma group, failures in the control subjects occurred most often (7/10) with small and crowded optic discs. In subjects who were successfully classified at least globally by the GPS (117 patients with glaucoma, 88 control subjects), the diagnostic performances of GPS and MRA were similar (areas under the receiver operating characteristic [ROC] curve of 0.78 and 0.77, respectively; P > 0.1). With the GPS, sensitivity and specificity were 59% and 91% (most specific criteria) and 78% and 63% (least specific criteria), respectively. Combining GPS and MRA did not increase diagnostic performance significantly (ROC area of combined classifiers, 0.81). Both GPS and MRA were affected by disc size. In patients with glaucoma as well as healthy control subjects, the odds of a positive GPS classification (borderline or outside normal limits) increased by 21% (95% confidence interval [CI], 12%-30%) for each 0.1 mm2 increase in optic disc area. With the MRA, the corresponding increase was 15% (95% CI, 7%-23%). Optic disc area alone accounted for approximately 30% and 22% of the explained variance with the GPS and MRA, respectively (P < 0.001). The proportional-odds logistic regression confirmed that optic disc size affected mainly the tradeoff between true- and false-positive classifications (criterion) rather than the absolute performance of the analyses (area under the ROC curve). There was some evidence of an age effect with the MRA, which showed a 53% (95% CI, 16%-102%) increase in the odds of a positive test (borderline or outside normal limits) associated with each decade of age (P = 0.002), but no age effects were observed with the GPS (P > 0.1). The diagnostic performance of the contour line-independent GPS analysis is similar to that of the MRA. However, clinicians should be aware of the strong size dependence of both GPS and MRA. In large optic discs, both GPS and MRA are likely to produce many false-positive classifications. Correspondingly, the sensitivity to early damage is likely to be low in small optic discs. There is a need for automated classification systems that explicitly address the size dependence of current analyses.
Telepathology. Long-distance diagnosis.
Weinstein, R S; Bloom, K J; Rozek, L S
1989-04-01
Telepathology is defined as the practice of pathology at a distance, by visualizing an image on a video monitor rather than viewing a specimen directly through a microscope. Components of a telepathology system include the following: (1) a workstation equipped with a high-resolution video camera attached to a remote-controlled light microscope; (2) a pathologist workstation incorporating controls for manipulating the robotic microscope as well as a high-resolution video monitor; and (3) a telecommunications link. Progress has been made in designing and constructing telepathology workstations and fully motorized, computer-controlled light microscopes suitable for telepathology. In addition, components such as video signal digital encoders and decoders that produce remarkably stable, high-color fidelity, and high-resolution images have been incorporated into the workstations. Resolution requirements for the video microscopy component of telepathology have been formally examined in receiver operator characteristic (ROC) curve analyses. Test-of-concept demonstrations have been completed with the use of geostationary satellites as the broadband communication linkages for 750-line resolution video. Potential benefits of telepathology include providing a means of conveniently delivering pathology services in real-time to remote sites or underserviced areas, time-sharing of pathologists' services by multiple institutions, and increasing accessibility to specialty pathologists.
Recognition Errors Suggest Fast Familiarity and Slow Recollection in Rhesus Monkeys
ERIC Educational Resources Information Center
Basile, Benjamin M.; Hampton, Robert R.
2013-01-01
One influential model of recognition posits two underlying memory processes: recollection, which is detailed but relatively slow, and familiarity, which is quick but lacks detail. Most of the evidence for this dual-process model in nonhumans has come from analyses of receiver operating characteristic (ROC) curves in rats, but whether ROC analyses…
ERIC Educational Resources Information Center
Dube, Chad; Starns, Jeffrey J.; Rotello, Caren M.; Ratcliff, Roger
2012-01-01
A classic question in the recognition memory literature is whether retrieval is best described as a continuous-evidence process consistent with signal detection theory (SDT), or a threshold process consistent with many multinomial processing tree (MPT) models. Because receiver operating characteristics (ROCs) based on confidence ratings are…
To Duc, Khanh
2017-11-18
Receiver operating characteristic (ROC) surface analysis is usually employed to assess the accuracy of a medical diagnostic test when there are three ordered disease status (e.g. non-diseased, intermediate, diseased). In practice, verification bias can occur due to missingness of the true disease status and can lead to a distorted conclusion on diagnostic accuracy. In such situations, bias-corrected inference tools are required. This paper introduce an R package, named bcROCsurface, which provides utility functions for verification bias-corrected ROC surface analysis. The shiny web application of the correction for verification bias in estimation of the ROC surface analysis is also developed. bcROCsurface may become an important tool for the statistical evaluation of three-class diagnostic markers in presence of verification bias. The R package, readme and example data are available on CRAN. The web interface enables users less familiar with R to evaluate the accuracy of diagnostic tests, and can be found at http://khanhtoduc.shinyapps.io/bcROCsurface_shiny/ .
NASA Technical Reports Server (NTRS)
Fielhauer, Karl, B.; Boone, Bradley, G.; Raible, Daniel, E.
2012-01-01
This paper describes a system engineering approach to examining the potential for combining elements of a deep-space RF and optical communications payload, for the purpose of reducing the size, weight and power burden on the spacecraft and the mission. Figures of merit and analytical methodologies are discussed to conduct trade studies, and several potential technology integration strategies are presented. Finally, the NASA Integrated Radio and Optical Communications (iROC) project is described, which directly addresses the combined RF and optical approach.
Validation of Thwaites Index for diagnosing tuberculous meningitis in a Colombian population.
Saavedra, Juan Sebastián; Urrego, Sebastián; Toro, María Eugenia; Uribe, Carlos Santiago; García, Jenny; Hernández, Olga; Arango, Juan Carlos; Pérez, Ángela Beatriz; Franco, Andrés; Vélez, Isabel Cristina; Del Corral, Helena
2016-11-15
To determine the diagnostic accuracy of Thwaites Index (TI) in a Colombian population to distinguish meningeal tuberculosis (MTB) from bacterial meningitis (BM) and from non-tuberculous meningitis. Exploratory analyses were conducted to assess the TI's validity for patients with human immunodeficiency virus (HIV) and children above six-years-old. The study included 527 patients, the TI was calculated and results compared with those of a reference standard established by expert neurologists. Sensitivity, specificity, area under the curve of receiver-operator characteristics (AUC-ROC) and likelihood ratios were calculated. The AUC-ROC to distinguish MTB from non-tuberculous meningitis was 0.72 (95% CI: 0.67-0.77) for HIV negative adults. AUC-ROC was 0.62 (95% CI: 0.50-0.74) for HIV positive adults and 0.83 (95% CI: 0.68-0.97) for children. For distinguishing MTB from BM the AUC-ROC was 0.78 (95% CI: 0.73-0.83); furthermore, the AUC-ROC was 0.57 (95% CI: 0.31-0.83) for HIV positive adults and 0.86 (95% CI: 0.73-0.99) for children. The TI was sensitive but not specific when used to distinguish MTB from BM in HIV negative adults. In HIV positive adults the index had low diagnostic accuracy. Moreover, the TI showed discrimination capability for children over 6years; however, research with larger samples is required in these. Copyright © 2016 Elsevier B.V. All rights reserved.
Wixted, John T; Mickes, Laura
2018-01-01
Receiver operating characteristic (ROC) analysis was introduced to the field of eyewitness identification 5 years ago. Since that time, it has been both influential and controversial, and the debate has raised an issue about measuring discriminability that is rarely considered. The issue concerns the distinction between empirical discriminability (measured by area under the ROC curve) vs. underlying/theoretical discriminability (measured by d' or variants of it). Under most circumstances, the two measures will agree about a difference between two conditions in terms of discriminability. However, it is possible for them to disagree, and that fact can lead to confusion about which condition actually yields higher discriminability. For example, if the two conditions have implications for real-world practice (e.g., a comparison of competing lineup formats), should a policymaker rely on the area-under-the-curve measure or the theory-based measure? Here, we illustrate the fact that a given empirical ROC yields as many underlying discriminability measures as there are theories that one is willing to take seriously. No matter which theory is correct, for practical purposes, the singular area-under-the-curve measure best identifies the diagnostically superior procedure. For that reason, area under the ROC curve informs policy in a way that underlying theoretical discriminability never can. At the same time, theoretical measures of discriminability are equally important, but for a different reason. Without an adequate theoretical understanding of the relevant task, the field will be in no position to enhance empirical discriminability.
AVC: Selecting discriminative features on basis of AUC by maximizing variable complementarity.
Sun, Lei; Wang, Jun; Wei, Jinmao
2017-03-14
The Receiver Operator Characteristic (ROC) curve is well-known in evaluating classification performance in biomedical field. Owing to its superiority in dealing with imbalanced and cost-sensitive data, the ROC curve has been exploited as a popular metric to evaluate and find out disease-related genes (features). The existing ROC-based feature selection approaches are simple and effective in evaluating individual features. However, these approaches may fail to find real target feature subset due to their lack of effective means to reduce the redundancy between features, which is essential in machine learning. In this paper, we propose to assess feature complementarity by a trick of measuring the distances between the misclassified instances and their nearest misses on the dimensions of pairwise features. If a misclassified instance and its nearest miss on one feature dimension are far apart on another feature dimension, the two features are regarded as complementary to each other. Subsequently, we propose a novel filter feature selection approach on the basis of the ROC analysis. The new approach employs an efficient heuristic search strategy to select optimal features with highest complementarities. The experimental results on a broad range of microarray data sets validate that the classifiers built on the feature subset selected by our approach can get the minimal balanced error rate with a small amount of significant features. Compared with other ROC-based feature selection approaches, our new approach can select fewer features and effectively improve the classification performance.
Ikdahl, Eirik; Rollefstad, Silvia; Olsen, Inge C; Kvien, Tore K; Hansen, Inger Johanne Widding; Soldal, Dag Magnar; Haugeberg, Glenn; Semb, Anne Grete
2015-01-01
EULAR recommendations for cardiovascular disease (CVD) risk management include annual CVD risk assessments for patients with rheumatoid arthritis (RA). We evaluated the recording of CVD risk factors (CVD-RF) in a rheumatology outpatient clinic, where EULAR recommendations had been implemented. Further, we compared CVD-RF recordings between a regular rheumatology outpatient clinic (RegROC) and a structured arthritis clinic (AC). In 2012, 1142 RA patients visited the rheumatology outpatient clinic: 612 attended RegROC and 530 attended AC. We conducted a search in the patient journals to ascertain the rate of CVD-RF recording. The overall CVD-RF recording rate was 40.1% in the rheumatology outpatient clinic, reflecting a recording rate of 59.1% in the AC and 23.6% in the RegROC. The odds ratios for having CVD-RFs recorded for patients attending AC compared to RegROC were as follows: blood pressure: 12.4, lipids: 5.0-6.0, glucose: 9.1, HbA1c: 6.1, smoking: 1.4, and for having all the CVD-RFs needed to calculate the CVD risk by the systematic coronary risk evaluation (SCORE): 21.0. The CVD-RF recording rate was low in a rheumatology outpatient clinic. However, a systematic team-based model was superior compared to a RegROC. Further measures are warranted to improve CVD-RF recording in RA patients.
Chaux, Alcides
2015-10-01
To evaluate the accuracy of previously published risk group systems for predicting inguinal nodal metastases in patients with penile carcinoma. Two hundred three cases of invasive penile squamous cell carcinomas (SCC) were stratified using the following systems: Solsona et al (J Urol 2001;165:1509), Hungerhuber et al (Urology 2006;68:621), and the system proposed by the European Association of Urology (EAU; Eur Urol 2004;46:1). Receiver operating characteristic (ROC) analysis was carried out to compare accuracy in predicting final nodal status and cancer-related death. Most of cases were pT2/pT3 high-grade tumors with a small percentage of low-grade pT1 carcinomas. The metastatic rates for the Solsona et al, EAU, and Hungerhuber et al systems in the high-risk category were 15 of 73 (21%), 16 of 103 (16%), and 10 of 35 (29%) in patients with clinically negative inguinal lymph nodes and 52 of 75 (69%), 55 of 93 (59%), and 34 of 47 (72%) in patients with palpable inguinal lymph nodes, respectively. Performance by ROC analysis showed a low accuracy for all stratification systems although the Solsona et al and the Hungerhuber et al systems performed better than the EAU system. Patients in intermediate-risk categories and with clinically palpable inguinal lymph nodes were more likely to have nodal metastasis than patients with clinically negative lymph nodes in the same category. These stratification systems may be useful for patients with low-grade superficial tumors and less accurate for evaluating patients with high-grade locally advanced penile carcinomas. These data may be useful for therapeutic planning of patients with penile SCC. Copyright © 2015 Elsevier Inc. All rights reserved.
Main, Keith L; Soman, Salil; Pestilli, Franco; Furst, Ansgar; Noda, Art; Hernandez, Beatriz; Kong, Jennifer; Cheng, Jauhtai; Fairchild, Jennifer K; Taylor, Joy; Yesavage, Jerome; Wesson Ashford, J; Kraemer, Helena; Adamson, Maheen M
2017-01-01
Standard MRI methods are often inadequate for identifying mild traumatic brain injury (TBI). Advances in diffusion tensor imaging now provide potential biomarkers of TBI among white matter fascicles (tracts). However, it is still unclear which tracts are most pertinent to TBI diagnosis. This study ranked fiber tracts on their ability to discriminate patients with and without TBI. We acquired diffusion tensor imaging data from military veterans admitted to a polytrauma clinic (Overall n = 109; Age: M = 47.2, SD = 11.3; Male: 88%; TBI: 67%). TBI diagnosis was based on self-report and neurological examination. Fiber tractography analysis produced 20 fiber tracts per patient. Each tract yielded four clinically relevant measures (fractional anisotropy, mean diffusivity, radial diffusivity, and axial diffusivity). We applied receiver operating characteristic (ROC) analyses to identify the most diagnostic tract for each measure. The analyses produced an optimal cutpoint for each tract. We then used kappa coefficients to rate the agreement of each cutpoint with the neurologist's diagnosis. The tract with the highest kappa was most diagnostic. As a check on the ROC results, we performed a stepwise logistic regression on each measure using all 20 tracts as predictors. We also bootstrapped the ROC analyses to compute the 95% confidence intervals for sensitivity, specificity, and the highest kappa coefficients. The ROC analyses identified two fiber tracts as most diagnostic of TBI: the left cingulum (LCG) and the left inferior fronto-occipital fasciculus (LIF). Like ROC, logistic regression identified LCG as most predictive for the FA measure but identified the right anterior thalamic tract (RAT) for the MD, RD, and AD measures. These findings are potentially relevant to the development of TBI biomarkers. Our methods also demonstrate how ROC analysis may be used to identify clinically relevant variables in the TBI population.
A new comparison of hyperspectral anomaly detection algorithms for real-time applications
NASA Astrophysics Data System (ADS)
Díaz, María.; López, Sebastián.; Sarmiento, Roberto
2016-10-01
Due to the high spectral resolution that remotely sensed hyperspectral images provide, there has been an increasing interest in anomaly detection. The aim of anomaly detection is to stand over pixels whose spectral signature differs significantly from the background spectra. Basically, anomaly detectors mark pixels with a certain score, considering as anomalies those whose scores are higher than a threshold. Receiver Operating Characteristic (ROC) curves have been widely used as an assessment measure in order to compare the performance of different algorithms. ROC curves are graphical plots which illustrate the trade- off between false positive and true positive rates. However, they are limited in order to make deep comparisons due to the fact that they discard relevant factors required in real-time applications such as run times, costs of misclassification and the competence to mark anomalies with high scores. This last fact is fundamental in anomaly detection in order to distinguish them easily from the background without any posterior processing. An extensive set of simulations have been made using different anomaly detection algorithms, comparing their performances and efficiencies using several extra metrics in order to complement ROC curves analysis. Results support our proposal and demonstrate that ROC curves do not provide a good visualization of detection performances for themselves. Moreover, a figure of merit has been proposed in this paper which encompasses in a single global metric all the measures yielded for the proposed additional metrics. Therefore, this figure, named Detection Efficiency (DE), takes into account several crucial types of performance assessment that ROC curves do not consider. Results demonstrate that algorithms with the best detection performances according to ROC curves do not have the highest DE values. Consequently, the recommendation of using extra measures to properly evaluate performances have been supported and justified by the conclusions drawn from the simulations.
Filling in the blanks. An estimation of illicit cannabis growers' profits in Belgium.
Vanhove, Wouter; Surmont, Tim; Van Damme, Patrick; De Ruyver, Brice
2014-05-01
As a result of increased pressure on cannabis cultivation in The Netherlands, the number of confiscated indoor cannabis plantations in Belgium is rising. Although increases are reported for all plantations sizes, half of the seized plantations contain less than 50 plants. In this study, factors and variables that influence costs and benefits of indoor cannabis cultivation are investigated as well as how these costs and benefits vary between different cannabis grower types. Real-situation data of four growers were used to perform financial analyses. Costs included fixed and variable material costs, as well as opportunity costs. Gross revenue per grow cycle was calculated based on most recent forensic findings for illicit Belgian cannabis plantations and was adjusted for the risk of getting caught. Finally, gross revenues and return on costs (ROC) were calculated over 1 year (4 cycles). Financial analysis shows that in all cases gross revenues as well as ROC are considerable, even after a single growth cycle. Highest profitability was found for large-scale (600 plants, ROC=6.8) and mid-scale plantations (150 plants, ROC=6.0). However, industrial plantations (23,000 plants, ROC=1.4) and micro-scale plantations (5 plants, ROC=2.8) are also highly remunerative. Shift of police focus away from micro-scale growers, least likely to be involved in criminal gangs, to large-scale and industrial scale plantations would influence costs as a result of changing risks of getting caught. However, sensitivity analysis shows that this does not significantly influence the conclusions on profitability of different types of indoor cannabis growers. Seizure and confiscation of profits are important elements in the integral and integrated policy approach required for tackling illicit indoor cannabis plantations. The large return of costs evidenced in the present study, underpin the policy relevance of confiscating those illicit profits as part of enforcement. Copyright © 2014 Elsevier B.V. All rights reserved.
ROC curves predicted by a model of visual search.
Chakraborty, D P
2006-07-21
In imaging tasks where the observer is uncertain whether lesions are present, and where they could be present, the image is searched for lesions. In the free-response paradigm, which closely reflects this task, the observer provides data in the form of a variable number of mark-rating pairs per image. In a companion paper a statistical model of visual search has been proposed that has parameters characterizing the perceived lesion signal-to-noise ratio, the ability of the observer to avoid marking non-lesion locations, and the ability of the observer to find lesions. The aim of this work is to relate the search model parameters to receiver operating characteristic (ROC) curves that would result if the observer reported the rating of the most suspicious finding on an image as the overall rating. Also presented are the probability density functions (pdfs) of the underlying latent decision variables corresponding to the highest rating for normal and abnormal images. The search-model-predicted ROC curves are 'proper' in the sense of never crossing the chance diagonal and the slope is monotonically changing. They also have the interesting property of not allowing the observer to move the operating point continuously from the origin to (1, 1). For certain choices of parameters the operating points are predicted to be clustered near the initial steep region of the curve, as has been observed by other investigators. The pdfs are non-Gaussians, markedly so for the abnormal images and for certain choices of parameter values, and provide an explanation for the well-known observation that experimental ROC data generally imply a wider pdf for abnormal images than for normal images. Some features of search-model-predicted ROC curves and pdfs resemble those predicted by the contaminated binormal model, but there are significant differences. The search model appears to provide physical explanations for several aspects of experimental ROC curves.
Paprott, Rebecca; Mühlenbruch, Kristin; Mensink, Gert B M; Thiele, Silke; Schulze, Matthias B; Scheidt-Nave, Christa; Heidemann, Christin
2016-01-01
Objective To evaluate the German Diabetes Risk Score (GDRS) among the general adult German population for prediction of incident type 2 diabetes and detection of prevalent undiagnosed diabetes. Methods The longitudinal sample for prediction of incident diagnosed type 2 diabetes included 3625 persons who participated both in the examination survey in 1997–1999 and the examination survey in 2008–2011. Incident diagnosed type 2 diabetes was defined as first-time physician diagnosis or antidiabetic medication during 5 years of follow-up excluding potential incident type 1 and gestational diabetes. The cross-sectional sample for detection of prevalent undiagnosed diabetes included 6048 participants without diagnosed diabetes of the examination survey in 2008–2011. Prevalent undiagnosed diabetes was defined as glycated haemoglobin ≥6.5% (48 mmol/mol). We assessed discrimination as area under the receiver operating characteristic curve (ROC-AUC (95% CI)) and calibration through calibration plots. Results In longitudinal analyses, 82 subjects with incident diagnosed type 2 diabetes were identified after 5 years of follow-up. For prediction of incident diagnosed diabetes, the GDRS yielded an ROC-AUC of 0.87 (0.83 to 0.90). Calibration plots indicated excellent prediction for low diabetes risk and overestimation for intermediate and high diabetes risk. When considering the entire follow-up period of 11.9 years (ROC-AUC: 0.84 (0.82 to 0.86)) and including incident undiagnosed diabetes (ROC-AUC: 0.81 (0.78 to 0.84)), discrimination decreased somewhat. A previously simplified paper version of the GDRS yielded a similar predictive ability (ROC-AUC: 0.86 (0.82 to 0.89)). In cross-sectional analyses, 128 subjects with undiagnosed diabetes were identified. For detection of prevalent undiagnosed diabetes, the ROC-AUC was 0.84 (0.81 to 0.86). Again, the simplified version yielded a similar result (ROC-AUC: 0.83 (0.80 to 0.86)). Conclusions The GDRS might be applied for public health monitoring of diabetes risk in the German adult population. Future research needs to evaluate whether the GDRS is useful to improve diabetes risk awareness and prevention among the general population. PMID:27933187
Development of a gambling addictive behavior scale for adolescents in Korea.
Park, Hyun Sook; Jung, Sun Young
2012-12-01
This study was conducted to develop a gambling addictive behavior scale for adolescents. The process involved construction of a conceptual framework, initial item search, verification of content validity, selection of secondary items, and extraction of final items. The participants were 299 adolescents from two middle schools and four high schools. Item analysis, factor analysis, criterion validity, internal consistency, and ROC curve were used to analyze the data. For the final scale, 25 items were selected, and categorized into 4 factors which accounted for 54.9% of the total variance. The factors were labeled as loss of control, life dysfunction from gambling addiction, gambling experience, and social dysfunction from problem gambling. The scores for the scale were significantly correlated with addictive personality, irrational gambling belief, and adolescent's gambling addictive behavior. Cronbach's alpha coefficient for the 25 items was .94. Scale scores identified adolescents as being in a problem gambling group, a non-problem gambling group, and a non-gambling group by the ROC curve. The above findings indicate that the gambling addictive behavior scale has good validity and reliability and can be used with adolescents in Korea.
Meisters, Julia; Diedenhofen, Birk; Musch, Jochen
2018-04-20
For decades, sequential lineups have been considered superior to simultaneous lineups in the context of eyewitness identification. However, most of the research leading to this conclusion was based on the analysis of diagnosticity ratios that do not control for the respondent's response criterion. Recent research based on the analysis of ROC curves has found either equal discriminability for sequential and simultaneous lineups, or higher discriminability for simultaneous lineups. Some evidence for potential position effects and for criterion shifts in sequential lineups has also been reported. Using ROC curve analysis, we investigated the effects of the suspect's position on discriminability and response criteria in both simultaneous and sequential lineups. We found that sequential lineups suffered from an unwanted position effect. Respondents employed a strict criterion for the earliest lineup positions, and shifted to a more liberal criterion for later positions. No position effects and no criterion shifts were observed in simultaneous lineups. This result suggests that sequential lineups are not superior to simultaneous lineups, and may give rise to unwanted position effects that have to be considered when conducting police lineups.
No special K! A signal detection framework for the strategic regulation of memory accuracy.
Higham, Philip A
2007-02-01
Two experiments investigated criterion setting and metacognitive processes underlying the strategic regulation of accuracy on the Scholastic Aptitude Test (SAT) using Type-2 signal detection theory (SDT). In Experiment 1, report bias was manipulated by penalizing participants either 0.25 (low incentive) or 4 (high incentive) points for each error. Best guesses to unanswered items were obtained so that Type-2 signal detection indices of discrimination and bias could be calculated. The same incentive manipulation was used in Experiment 2, only the test was computerized, confidence ratings were taken so that receiver operating characteristic (ROC) curves could be generated, and feedback was manipulated. The results of both experiments demonstrated that SDT provides a viable alternative to A. Koriat and M. Goldsmith's (1996c) framework of monitoring and control and reveals information about the regulation of accuracy that their framework does not. For example, ROC analysis indicated that the threshold model implied by formula scoring is inadequate. Instead, performance on the SAT should be modeled with an equal-variance Gaussian, Type-2 signal detection model. ((c) 2007 APA, all rights reserved).
Electrodiagnosis of ulnar neuropathy at the elbow (Une): a Bayesian approach.
Logigian, Eric L; Villanueva, Raissa; Twydell, Paul T; Myers, Bennett; Downs, Marlene; Preston, David C; Kothari, Milind J; Herrmann, David N
2014-03-01
In ulnar neuropathy at the elbow (UNE), we determined how electrodiagnostic cutoffs [across-elbow ulnar motor conduction velocity slowing (AECV-slowing), drop in across-elbow vs. forearm CV (AECV-drop)] depend on pretest probability (PreTP). Fifty clinically defined UNE patients and 50 controls underwent ulnar conduction testing recording abductor digiti minimi (ADM) and first dorsal interosseous (FDI), stimulating wrist, below-elbow, and 6-, 8-, and 10-cm more proximally. For various PreTPs of UNE, the cutoffs required to confirm UNE (defined as posttest probability = 95%) were determined with receiver operator characteristic (ROC) curves and Bayes Theorem. On ROC and Bayesian analyses, the ADM 10-cm montage was optimal. For PreTP = 0.25, the confirmatory cutoffs were >23 m/s (AECV-drop), and <38 m/s (AECV-slowing); for PreTP = 0.75, they were much less conservative: >14 m/s, and <47 m/s, respectively. (1) In UNE, electrodiagnostic cutoffs are critically dependent on PreTP; rigid cutoffs are problematic. (2) AE distances should be standardized and at least 10 cm. Copyright © 2013 Wiley Periodicals, Inc.
Berger, Sanne Schou; Lauritsen, Klara Tølbøll; Boas, Ulrik; Lind, Peter; Andresen, Lars Ole
2017-11-01
We developed and made a preliminary validation of a bead-based multiplexed immunoassay for simultaneous detection of porcine serum antibodies to Actinobacillus pleuropneumoniae serovars 1, 2, 6, 7, and 12. Magnetic fluorescent beads were coupled with A. pleuropneumoniae antigens and tested with a panel of serum samples from experimentally infected pigs and with serum samples from uninfected and naturally infected pigs. The multiplex assay was compared to in-house ELISAs and complement fixation (CF) tests, which have been used for decades as tools for herd classification in the Danish Specific Pathogen Free system. Assay specificities and sensitivities as well as the corresponding cutoff values were determined using receiver operating characteristic (ROC) curve analysis, and the A. pleuropneumoniae multiplex assay showed good correlation with the in-house ELISAs and CF tests with areas under ROC curves ≥ 0.988. Benefits of multiplexed assays compared to ELISAs and CF tests include reduced serum sample volumes needed for analysis, less labor, and shorter assay time.
NASA Astrophysics Data System (ADS)
Zhou, Weimin; Anastasio, Mark A.
2018-03-01
It has been advocated that task-based measures of image quality (IQ) should be employed to evaluate and optimize imaging systems. Task-based measures of IQ quantify the performance of an observer on a medically relevant task. The Bayesian Ideal Observer (IO), which employs complete statistical information of the object and noise, achieves the upper limit of the performance for a binary signal classification task. However, computing the IO performance is generally analytically intractable and can be computationally burdensome when Markov-chain Monte Carlo (MCMC) techniques are employed. In this paper, supervised learning with convolutional neural networks (CNNs) is employed to approximate the IO test statistics for a signal-known-exactly and background-known-exactly (SKE/BKE) binary detection task. The receiver operating characteristic (ROC) curve and the area under the ROC curve (AUC) are compared to those produced by the analytically computed IO. The advantages of the proposed supervised learning approach for approximating the IO are demonstrated.
Application of the Hotelling and ideal observers to detection and localization of exoplanets.
Caucci, Luca; Barrett, Harrison H; Devaney, Nicholas; Rodríguez, Jeffrey J
2007-12-01
The ideal linear discriminant or Hotelling observer is widely used for detection tasks and image-quality assessment in medical imaging, but it has had little application in other imaging fields. We apply it to detection of planets outside of our solar system with long-exposure images obtained from ground-based or space-based telescopes. The statistical limitations in this problem include Poisson noise arising mainly from the host star, electronic noise in the image detector, randomness or uncertainty in the point-spread function (PSF) of the telescope, and possibly a random background. PSF randomness is reduced but not eliminated by the use of adaptive optics. We concentrate here on the effects of Poisson and electronic noise, but we also show how to extend the calculation to include a random PSF. For the case where the PSF is known exactly, we compare the Hotelling observer to other observers commonly used for planet detection; comparison is based on receiver operating characteristic (ROC) and localization ROC (LROC) curves.
Application of the Hotelling and ideal observers to detection and localization of exoplanets
Caucci, Luca; Barrett, Harrison H.; Devaney, Nicholas; Rodríguez, Jeffrey J.
2008-01-01
The ideal linear discriminant or Hotelling observer is widely used for detection tasks and image-quality assessment in medical imaging, but it has had little application in other imaging fields. We apply it to detection of planets outside of our solar system with long-exposure images obtained from ground-based or space-based telescopes. The statistical limitations in this problem include Poisson noise arising mainly from the host star, electronic noise in the image detector, randomness or uncertainty in the point-spread function (PSF) of the telescope, and possibly a random background. PSF randomness is reduced but not eliminated by the use of adaptive optics. We concentrate here on the effects of Poisson and electronic noise, but we also show how to extend the calculation to include a random PSF. For the case where the PSF is known exactly, we compare the Hotelling observer to other observers commonly used for planet detection; comparison is based on receiver operating characteristic (ROC) and localization ROC (LROC) curves. PMID:18059905
Ribeiro, Vanessa da S; Nunes, Daniela da S; Gonzaga, Henrique T; da Cunha-Junior, Jair P; Costa-Cruz, Julia M
2014-07-01
Neurocysticercosis (NC) is one of the most important diseases caused by parasites affecting the central nervous system. We fractionated by ion-exchange chromatography using diethylaminoethyl (DEAE)-sepharose resin the total saline extract (S) from Taenia solium metacestodes and evaluated obtained fractions (DEAE S1 and DEAE S2) by enzyme-linked immunosorbent assay (ELISA, n = 123) and immunoblotting (IB, n = 22) to detect human NC in serum. Diagnostic parameters were established by ROC and TG ROC curves for ELISA tests. IB was qualitatively analyzed. S and DEAE S1 presented sensitivity of 87. 5% and DEAE S2 90%. The best specificity was observed for DEAE S2 (90.4%). In IB, using DEAE S2 samples from NC patients presented bands of 20-25, 43-45, 55-50, 60-66, 82, 89, and 140 kDa. The great diagnostic parameters reached by DEAE S2 suggest the potential applicability of this fraction in NC immunodiagnosis.
Segmentation and feature extraction of retinal vascular morphology
NASA Astrophysics Data System (ADS)
Leopold, Henry A.; Orchard, Jeff; Zelek, John; Lakshminarayanan, Vasudevan
2017-02-01
Analysis of retinal fundus images is essential for physicians, optometrists and ophthalmologists in the diagnosis, care and treatment of patients. The first step of almost all forms of automated fundus analysis begins with the segmentation and subtraction of the retinal vasculature, while analysis of that same structure can aid in the diagnosis of certain retinal and cardiovascular conditions, such as diabetes or stroke. This paper investigates the use of a Convolutional Neural Network as a multi-channel classifier of retinal vessels using DRIVE, a database of fundus images. The result of the network with the application of a confidence threshold was slightly below the 2nd observer and gold standard, with an accuracy of 0.9419 and ROC of 0.9707. The output of the network with on post-processing boasted the highest sensitivity found in the literature with a score of 0.9568 and a good ROC score of 0.9689. The high sensitivity of the system makes it suitable for longitudinal morphology assessments, disease detection and other similar tasks.
NASA Astrophysics Data System (ADS)
Stelzle, Florian; Zam, Azhar; Adler, Werner; Douplik, Alexandre; Tangermann-Gerk, Katja; Nkenke, Emeka; Neukam, Friedrich Wilhelm; Schmidt, Michael
Objective: Laser surgery has many advantages. However, due to a lack of haptic feedback it is accompanied by the risk of iatrogenic nerve damage. The aim of this study was to evaluate the possibilities of optical nerve identification by diffuse reflectance spectroscopy to set the base for a feedback control system to enhance nerve preservation in oral and maxillofacial laser surgery. Materials and Methods: Diffuse reflectance spectra of nerve tissue, skin, mucosa, fat tissue, muscle, cartilage and bone (15120 spectra) of ex vivo pig heads were acquired in the wavelength range of 350-650 nm. Tissue differentiation was performed by principal components analysis (PCA) followed by linear discriminant analysis (LDA). Specificity and sensitivity were calculated by receiver operating characteristic (ROC) analysis and the area under curve (AUC). Results: Nerve tissue could correctly be identified and differed from skin, mucosa, fat tissue, muscle, cartilage and bone in more than 90% of the cases (AUC results) with a specificity of over 78% and a sensitivity of more than 86%. Conclusion: Nerve tissue can be identified by diffuse reflectance spectroscopy with high precision and reliability. The results may set the base for a feedback system to prevent iatrogenic nerve damage performing oral and maxillofacial laser surgery.
Sporer, Siegfried L; Kaminski, Kristina S; Davids, Maike C; McQuiston, Dawn
2016-11-01
When witnesses report a crime, police usually ask for a description of the perpetrator. Several studies suggested that verbalising faces leads to a detriment in identification performance (verbal overshadowing effect [VOE]) but the effect has been difficult to replicate. Here, we sought to reverse the VOE by inducing context reinstatement as a system variable through re-reading one's own description before an identification task. Participants (N = 208) watched a video film and were then dismissed (control group), only described the perpetrator, or described and later re-read their own descriptions before identification in either target-present or target-absent lineups after a 2-day or a 5-week delay. Identification accuracy was significantly higher after re-reading (85.0%) than in the no description control group (62.5%) irrespective of target presence. Data were internally replicated using a second target and corroborated by several small meta-analyses. Identification accuracy was related to description quality. Moreover, there was a tendency towards a verbal facilitation effect (VFE) rather than a VOE. Receiver operating characteristic (ROC) curve analyses confirm that our findings are not due to a shift in response bias but truly reflect improvement of recognition performance. Differences in the ecological validity of study paradigms are discussed.
Separating Mnemonic Process from Participant and Item Effects in the Assessment of ROC Asymmetries
ERIC Educational Resources Information Center
Pratte, Michael S.; Rouder, Jeffrey N.; Morey, Richard D.
2010-01-01
One of the most influential findings in the study of recognition memory is that receiver operating characteristic (ROC) curves are asymmetric about the negative diagonal. This result has led to the rejection of the equal-variance signal detection model of recognition memory and has provided motivation for more complex models, such as the…
Item Strength Influences Source Confidence and Alters Source Memory zROC Slopes
ERIC Educational Resources Information Center
Starns, Jeffrey J.; Ksander, John C.
2016-01-01
Increasing the number of study trials creates a crossover pattern in source memory zROC slopes; that is, the slope is either below or above 1 depending on which source receives stronger learning. This pattern can be produced if additional learning affects memory processes such as the relative contribution of recollection and familiarity to source…
Laterally-Biased Quantum IR Detectors
2013-10-23
Rocío San-Román, Adrián Hierro , Journal of Crystal Growth 323, (2011), 496-500. [3] Semiconductor Devices: Physics and Technology 2nd Ed., S.M. Sze...6] “Laterally biased double quantum well IR detector fabricated by MBE regrowth”, Álvaro Guzmán, Rocío San-Román, Adrián Hierro , 16th
ERIC Educational Resources Information Center
Vivo, Juana-Maria; Franco, Manuel
2008-01-01
This article attempts to present a novel application of a method of measuring accuracy for academic success predictors that could be used as a standard. This procedure is known as the receiver operating characteristic (ROC) curve, which comes from statistical decision techniques. The statistical prediction techniques provide predictor models and…
Matched Filter Stochastic Background Characterization for Hyperspectral Target Detection
2005-09-30
and Pre- Clustering MVN Test.....................126 4.2.3 Pre- Clustering Detection Results.................................................130...4.2.4 Pre- Clustering Target Influence..................................................134 4.2.5 Statistical Distance Exclusion and Low Contrast...al, 2001] Figure 2.7 ROC Curve Comparison of RX, K-Means, and Bayesian Pre- Clustering Applied to Anomaly Detection [Ashton, 1998] Figure 2.8 ROC
López-Guerrero, José Antonio; Romero, Ignacio; Poveda, Andrés
2015-01-01
Epithelial ovarian cancer (OC) is a common gynecologic malignancy in women. The standard treatment for OC is maximal cytoreductive surgical debulking followed by platinum-based chemotherapy. Despite the high response rate to primary therapy, approximately 85% of patients will develop recurrent ovarian cancer (ROC). This review identifies the clinical use of trabectedin in the treatment algorithm for ROC, with specific emphasis on platinum-sensitive ROC, for which trabectedin in combination with pegylated liposomal doxorubicin has been approved as a treatment protocol. The main mechanisms of action of trabectedin at the cellular level and in the tumor microenvironment is also discussed as bases for identifying biomarkers for selecting patients who may largely benefit from trabectedin-based therapies.
Martins, Cristina; Dias, João; Pinto, José S
2014-01-01
Background Bariatric surgery is an important method for treatment of morbid obesity. It is known that significant nutritional deficiencies might occur after surgery, such as, calorie-protein malnutrition, iron deficiency anemia, and lack of vitamin B12, thiamine, and folic acid. Objective The objective of our study was to validate a computerized intelligent decision support system that suggests nutritional diagnoses of patients submitted to bariatric surgery. Methods There were fifteen clinical cases that were developed and sent to three dietitians in order to evaluate and define a nutritional diagnosis. After this step, the cases were sent to four bariatric surgery expert dietitians who were aiming to collaborate on a gold standard. The nutritional diagnosis was to be defined individually, and any disagreements were solved through a consensus. The final result was used as the gold standard. Bayesian networks were used to implement the system, and database training was done with Shell Netica. For the system validation, a similar answer rate was calculated, as well as the specificity and sensibility. Receiver operating characteristic (ROC) curves were projected to each nutritional diagnosis. Results Among the four experts, the rate of similar answers found was 80% (48/60) to 93% (56/60), depending on the nutritional diagnosis. The rate of similar answers of the system, compared to the gold standard, was 100% (60/60). The system sensibility and specificity were 95.0%. The ROC curves projection showed that the system was able to represent the expert knowledge (gold standard), and to help them in their daily tasks. Conclusions The system that was developed was validated to be used by health care professionals for decision-making support in their nutritional diagnosis of patients submitted to bariatric surgery. PMID:25601419
NASA Astrophysics Data System (ADS)
Hadaway, James B.; Wells, Conrad; Olczak, Gene; Waldman, Mark; Whitman, Tony; Cosentino, Joseph; Connolly, Mark; Chaney, David; Telfer, Randal
2016-07-01
The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment and phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development and spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software and procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate and efficient cryogenic testing of the JWST flight telescope.
NASA Technical Reports Server (NTRS)
Hadaway, James B.; Wells, Conrad; Olczak, Gene; Waldman, Mark; Whitman, Tony; Cosentino, Joseph; Connolly, Mark; Chaney, David; Telfer, Randal
2016-01-01
The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.
Interface Evaluation for Open System Architectures
2014-03-01
maker (SDM) is responsible for balancing all of the influences of the IPT when making decisions. Coalescing the IPT perspectives for a single IIM...factors are considered in IIM decisions and that decisions are consistent with the preferences of the SDM, ultimately leading to a balance of schedule... board to perform ranking and weighting determinations. Rank sum, rank exponent, rank reciprocal and ROC leverage a subjective assessment of the
2014-11-01
Paradigm ............................................................................19 3.4 Collaborative BCI for Improving Overall Performance...interfaces ( BCIs ) provide the biggest improvement in performance? Can we demonstrate clear advantages with BCIs ? 2 2. Simulator Development and...stimuli in real time. Fig. 18 ROC curves for each subject after the combination of 2 trials 3.4 Collaborative BCI for Improving Overall
Brubel, Reka; Bokor, Attila; Pohl, Akos; Schilli, Gabriella Krisztina; Szereday, Laszlo; Bacher-Szamuel, Reka; Rigo, Janos; Polgar, Beata
2017-12-01
To investigate the usefulness of soluble galectin-9 (Gal-9) in the noninvasive laboratory diagnosis of endometriosis and various gynecologic disorders. Prospective case-control study. University medical centers. A total of 135 women of reproductive age were involved in the study, 77 endometriosis patients, 28 gynecologic controls, and 30 healthy women. Diagnostic laparoscopy and collection of tissue biopsies, peritoneal cells, and native peripheral blood from different case groups of gynecology patients and healthy women. The expression of mRNA and serum concentration of Gal-9. Semiquantitative reverse transcription-polymerase chain reaction analysis and serum soluble Gal-9 ELISA were performed on three different cohorts of patients: those with endometriosis, those with benign gynecologic disorders, and healthy controls. Differences in the Gal-9 concentrations between the investigated groups and the stability of Gal-9 in the serum and diagnostic characteristics of Gal-9 ELISA were determined by statistical evaluation and receiver operating characteristic (ROC) curve analysis. Significantly elevated Gal-9 levels were found in both minimal-mild (I-II) and moderate-severe (III-IV) stages of endometriosis in comparison with healthy controls. At a cutoff of 132 pg/mL, ROC analysis revealed an excellent diagnostic value of Gal-9 ELISA in endometriosis (area under the curve = 0.973) with a sensitivity of 94% and specificity of 93.75%, indicating better diagnostic potential than that of other endometriosis biomarkers. Furthermore, various pelvic pain or infertility-associated benign gynecologic conditions were also associated with increased serum Gal-9 levels. Our results suggest that Gal-9 could be a promising noninvasive biomarker of endometriosis and a predictor of various infertility or pelvic pain-related gynecologic disorders. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
An evaluation of G-protein coupled membrane estrogen receptor-1 level in stuttering.
Bilal, Nagihan; Kurutas, Ergül Belge; Orhan, Israfil
2018-02-01
Stuttering is a widespread but little understood disease. There has been a recent increase in neuropathophysiological, genetic, and biochemical studies related to the etiopathogenesis. As developmental stuttering continues in adult males, hormonal factors are thought to have an effect. In this study, an evaluation was made for the first time of serum GPER-1 level in patients with a stutter. Prospective case control. The study included 30 patients with a stutter, aged < 18 years, and 35 age-matched children as the control group. The Stuttering Severity Instrument-3 form was administered to the patients. Evaluations were made of serum GPER-1, TSH, estradiol, prolactin, and progesterone and testosterone levels. GPER-1 level was determined as 0.51 (0.42-0.67) ng/mL in the patients and as 0.19 (0.13-0.25) ng/mL in the control group, and the difference was statistically significant (p < 0.001). A statistically significant difference was determined between genders with GPER-1 level of 0.56 (0.44-0.68) ng/mL in the male stuttering patient group and 0.44 (0.35-0.49) ng/mL in the female patient group (p = 0.026). Differential diagnosis with ROC analysis for the serum GPER-1 levels was statistically significant [Area under the ROC curve (AUC): 0.998, confidence interval, CI 0.992-1.000, p < 0.001]. The GPER-1 levels of the stuttering patients were found to be higher than those of the control group and GPER-1 levels of male patients were higher than those of females. As GPER-1 has high sensitivity and sensitivity, it could be considered important in the diagnosis and treatment of stuttering.
Sosic, Z; Gieler, U; Stangier, U
2008-06-01
To evaluate the German version of the Social Phobia Inventory (SPIN) as a screening device and to report corresponding cut-off scores for different populations. In Study 1, 2043 subjects from a representative sample completed the SPIN. Cut-off values were established on the basis of means and standard deviations. In Study 2, different aspects of validity were examined in a clinical sample comprising 164 subjects, including social phobic individuals, individuals with other anxiety disorders and depression, and non-clinical control subjects. Internal consistency was evaluated. Convergent and divergent validity were explored using several established measures. Finally, the sensitivity and specificity of the German SPIN with regard to social anxiety classification were investigated by means of receiver operating characteristics (ROC) analyses. In Study 1, mean scores and standard deviations were used to determine cut-off scores for the German SPIN. In Study 2, excellent internal consistency and good convergent and divergent validity were obtained. ROC analyses revealed that the German SPIN performed well in discriminating between social phobic individuals on the one hand and psychiatric and non-psychiatric controls on the other. A cut-off score of 25 represented the best balance between sensitivity and specificity. Comparable to the original version, the German SPIN demonstrates solid psychometric properties and shows promise as an economic, reliable, and valid screening device.
Sun, Ziwen; Shi, Xiaomin; Wang, Yun; Zhao, Yi
2018-06-05
An objective and quantitative method to evaluate psoriasis severity is important for practice and research in the precision care of psoriasis. We aimed to explore serum biomarkers quantitatively in association with disease severity and treatment response in psoriasis patients, with serum squamous cell carcinoma antigen (SCCA) evaluated in this pilot study. 15 psoriasis patients were treated with adalimumab. At different visits before and after treatment, quantitative body surface area (qBSA) was obtained from standardized digital body images of the patients, and the psoriasis area severity index (PASI) was also monitored. SCCA were detected by using microparticle enzyme immunoassay. The serum biomarkers were also tested in healthy volunteers as normal controls. Receiver-operating characteristic (ROC) curve analysis was used to explore the optimal cutoff point of SCCA to differentiate mild and moderate-to-severe psoriasis. The serum SCCA level in the psoriasis group was significantly higher (p < 0.05) than in the normal control group. After treatment, the serum SCCA levels were significantly decreased (p < 0.05). The SCCA level was well correlated with PASI and qBSA. In ROC analysis, when taking PASI = 10 or qBSA = 10% as the threshold, an optimal cutoff point of SCCA was found at 2.0 ng/mL with the highest Youden index. Serum SCCA might be a useful quantitative biomarker for psoriasis disease severity. © 2018 S. Karger AG, Basel.
Zhou, Weihua; Wei, Wenyi; Sun, Yi
2013-05-01
The SCF (SKP1 (S-phase-kinase-associated protein 1), Cullin-1, F-box protein) E3 ubiquitin ligases, the founding member of Cullin-RING ligases (CRLs), are the largest family of E3 ubiquitin ligases in mammals. Each individual SCF E3 ligase consists of one adaptor protein SKP1, one scaffold protein cullin-1 (the first family member of the eight cullins), one F-box protein out of 69 family members, and one out of two RING (Really Interesting New Gene) family proteins RBX1/ROC1 or RBX2/ROC2/SAG/RNF7. Various combinations of these four components construct a large number of SCF E3s that promote the degradation of many key regulatory proteins in cell-context, temporally, and spatially dependent manners, thus controlling precisely numerous important cellular processes, including cell cycle progression, apoptosis, gene transcription, signal transduction, DNA replication, maintenance of genome integrity, and tumorigenesis. To understand how the SCF E3 ligases regulate these cellular processes and embryonic development under in vivo physiological conditions, a number of mouse models with transgenic (Tg) expression or targeted deletion of components of SCF have been established and characterized. In this review, we will provide a brief introduction to the ubiquitin-proteasome system (UPS) and the SCF E3 ubiquitin ligases, followed by a comprehensive overview on the existing Tg and knockout (KO) mouse models of the SCF E3s, and discuss the role of each component in mouse embryogenesis, cell proliferation, apoptosis, carcinogenesis, as well as other pathogenic processes associated with human diseases. We will end with a brief discussion on the future directions of this research area and the potential applications of the knowledge gained to more effective therapeutic interventions of human diseases.
Impact of Strain Elastography on BI-RADS classification in small invasive lobular carcinoma.
Chiorean, Angelica Rita; Szep, Mădălina Brîndușa; Feier, Diana Sorina; Duma, Magdalena; Chiorean, Marco Andrei; Strilciuc, Ștefan
2018-05-02
The purpose of this study was to determine the impact of strain elastography (SE) on the Breast Imaging Reporting Data System (BI-RADS) classification depending on invasive lobular carcinoma (ILC) lesion size. We performed a retrospective analysis on a sample of 152 female subjects examined between January 2010 - January 2017. SE was performed on all patients and ILC was subsequently diagnosed by surgical or ultrasound-guided biopsy. BI-RADS 1, 2, 6 and Tsukuba BGR cases were omitted. BI-RADS scores were recorded before and after the use of SE. The differences between scores were compared to the ILC tumor size using nonparametric tests and logistic binary regression. We controlled for age, focality, clinical assessment, heredo-collateral antecedents, B-mode and Doppler ultrasound examination. An ROC curve was used to identify the optimal cut-off point for size in relationship to BI-RADS classificationdifference using Youden's index. The histological subtypes of ILC lesions (n=180) included in the sample were luminal A (70%, n=126), luminal B (27.78%, n=50), triple negative (1.67%, n=3) and HER2+ (0.56%, n=1). The BI-RADS classification was higher when SE was performed (Z=- 6.629, p<0.000). The ROC curve identified a cut-off point of 13 mm for size in relationship to BI-RADS classification difference (J=0.670, p<0.000). Small ILC tumors were 17.92% more likely to influence BI-RADS classification (p<0.000). SE offers enhanced BI-RADS classification in small ILC tumors (<13 mm). Sonoelastography brings added value to B-mode breast ultrasound as an adjacent to mammography in breast cancer screening.
Jeon, Yejoo; Jang, Eun Sun; Choi, Yun Suk; Kim, Jin-Wook; Jeong, Sook-Hyang
2016-09-01
Glypican-3 (GPC3) protein is highly expressed in hepatocellular carcinoma (HCC) tissue. It has been suggested as a diagnostic biomarker, but its inconsistent performance means that it requires further assessment. We therefore investigated the diagnostic value of the plasma GPC3 level compared to the alpha-fetoprotein (AFP) level as a diagnostic biomarker of HCC. We enrolled 157 consecutive patients with newly diagnosed HCC and 156 patients with liver cirrhosis (LC) as the control group. GPC3 plasma levels were measured using two commercially available enzyme-linked immunosorbent assays (ELISAs, named as Assay 1 and 2), and AFP levels were measured using an enzyme-linked chemiluminescent immunoassay. The diagnostic accuracy was analyzed using the receiver operating characteristics (ROC) curve. Plasma GPC3 levels in HCC patients were very low (0-3.09 ng/mL) in Assay 1, while only 3 of the 157 patients (1.9%) showed detectable GPC3 levels in Assay 2. The median GPC3 level was not significantly elevated in the HCC group (0.80 ng/mL) compared with the LC group (0.60 ng/mL). The area under the ROC curve (AUC) for GPC3 was 0.559 in Assay 1. In contrast, the median AFP level was significantly higher in HCC (27.72 ng/mL) than in LC (4.74 ng/mL), with an AUC of 0.729. The plasma level of GPC3 is a poor diagnostic marker for HCC, being far inferior to AFP. The development of a consistent detection system for the blood level of GPC3 is warranted.
Monach, Paul A; Warner, Roscoe L; Tomasson, Gunnar; Specks, Ulrich; Stone, John H; Ding, Linna; Fervenza, Fernando C; Fessler, Barri J; Hoffman, Gary S; Iklé, David; Kallenberg, Cees GM; Krischer, Jeffrey; Langford, Carol A; Mueller, Mark; Seo, Philip; St. Clair, E William; Spiera, Robert; Tchao, Nadia; Ytterberg, Steven R; Johnson, Kent J; Merkel, Peter A
2016-01-01
Objective To identify circulating proteins that distinguish between active anti-neutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV) and remission in a manner complementary to markers of systemic inflammation. Methods Twenty-eight serum proteins representing diverse aspects of the biology of AAV were measured before and 6 months after treatment in a large clinical trial of AAV. Subjects (n=186) enrolled in the Rituximab in ANCA-Associated Vasculitis (RAVE) trial were studied. Erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) levels were available for comparison. The primary outcome was the ability of markers to distinguish severe AAV (Birmingham Vasculitis Activity Score for Wegener’s granulomatosis (BVAS/WG)≥3 at screening) from remission (BVAS/WG=0 at month 6), using areas under receiver operating characteristic (ROC) curve (AUC). Results All subjects had severe active vasculitis (median BVAS/WG=8) at screening. In the 137 subjects in remission at month 6, 24 of the 28 markers showed significant declines. ROC analysis indicated that levels of CXCL13 (BCA-1), matrix metalloproteinase-3 (MMP-3) and tissue inhibitor of metalloproteinases-1 (TIMP-1) best discriminated active AAV from remission (AUC>0.8) and from healthy controls (AUC>0.9). Correlations among these markers and with ESR or CRP were low. Conclusions Many markers are elevated in severe active AAV and decline with treatment, but CXCL13, MMP-3 and TIMP-1 distinguish active AAV from remission better than the other markers studied, including ESR and CRP. These proteins are particularly promising candidates for future studies to address unmet needs in the assessment of patients with AAV. PMID:22975753
A highly sensitive and specific combined clinical and sonographic score to diagnose appendicitis.
Reddy, Swathi B; Kelleher, Michael; Bokhari, S A Jamal; Davis, Kimberly A; Schuster, Kevin M
2017-10-01
Computed tomography (CT) scanning reduces the negative appendectomy rate however it exposes the patient to ionizing radiation. Ultrasound (US) does not carry this risk but may be nondiagnostic. We hypothesized that a clinical-US scoring system would improve diagnostic accuracy. We conducted a retrospective review of all patients (age, >15 years) who presented through the emergency department with suspected appendicitis and underwent initial US. A US score was developed using odds ratios for appendicitis given appendiceal diameter, compressibility, hyperemia, free fluid, and focal or diffuse tenderness. The US score was then combined with the Alvarado score. Final diagnosis of appendicitis was assigned by pathology reports. Three hundred patients who underwent US as initial imaging were identified. Thirty-two patients with evident nonappendiceal pathology on US were excluded. In 114 (38%), the appendix was not visualized and partially visualized in 36 (12%). Fifty-seven (21.3%) had an appendectomy with 1 (1.7%) negative. Six nonvisualized appendicies underwent appendectomy, with no negative cases. Sensitivity and specificity for the sonographic score were 86% and 90%, respectively, at a score of 1.5. The combined score demonstrated 98% sensitivity and 82% specificity at 6.5, and 95% sensitivity, and 87% specificity at a score of 7.5. Sensitivity and specificity were confirmed by bootstrap resampling for validation. Area under receiver operating characteristic (ROC) curves for our new US score were similar to the ROC curve for the Alvarado score (91.9 and 91.1, p = 0.8). The combined US and Alvarado score yielded an area under the ROC curve of 97.1, significantly better than either score alone (p = 0.017 and p < 0.001, respectively). Our scoring system based entirely on US findings was highly sensitive and specific for appendicitis, and it significantly improved when combined with the Alvarado score. After prospective evaluation, the combined US-Alvarado score might replace the need for computed tomography imaging in a majority of patients. Diagnostic Test, Level III.
Short National Early Warning Score - Developing a Modified Early Warning Score.
Luís, Leandro; Nunes, Carla
2017-12-11
Early Warning Score (EWS) systems have been developed for detecting hospital patients clinical deterioration. Many studies show that a National Early Warning Score (NEWS) performs well in discriminating survival from death in acute medical and surgical hospital wards. NEWS is validated for Portugal and is available for use. A simpler EWS system may help to reduce the risk of error, as well as increase clinician compliance with the tool. The aim of the study was to evaluate whether a simplified NEWS model will improve use and data collection. We evaluated the ability of single and aggregated parameters from the NEWS model to detect patients' clinical deterioration in the 24h prior to an outcome. There were 2 possible outcomes: Survival vs Unanticipated intensive care unit admission or death. We used binary logistic regression models and Receiver Operating Characteristic Curves (ROC) to evaluate the parameters' performance in discriminating among the outcomes for a sample of patients from 6 Portuguese hospital wards. NEWS presented an excellent discriminating capability (Area under the Curve of ROC (AUCROC)=0.944). Temperature and systolic blood pressure (SBP) parameters did not contribute significantly to the model. We developed two different models, one without temperature, and the other by removing temperature and SBP (M2). Both models had an excellent discriminating capability (AUCROC: 0.965; 0.903, respectively) and a good predictive power in the optimum threshold of the ROC curve. The 3 models revealed similar discriminant capabilities. Although the use of SBP is not clearly evident in the identification of clinical deterioration, it is recognized as an important vital sign. We recommend the use of the first new model, as its simplicity may help to improve adherence and use by health care workers. Copyright © 2017 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Sagiyama, Koji; Watanabe, Yuji; Kamei, Ryotaro; Hong, Sungtak; Kawanami, Satoshi; Matsumoto, Yoshihiro; Honda, Hiroshi
2017-12-01
To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ( 18 FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. • PET/MR allows voxel-based comparison of SUVs and ADCs in soft-tissue tumours. • A comprehensive assessment of internal heterogeneity was performed with scatter plots. • SUVmax or ADCminimum could not differentiate high-grade sarcoma from low/intermediate-grade tumours. • Only the correlation coefficient between SUV and ADC differentiated the two groups. • The correlation coefficient showed the best diagnostic performance by ROC analysis.
Dumitrescu, Gabriel; Januszkiewicz, Anna; Ågren, Anna; Magnusson, Maria; Wahlin, Staffan; Wernerman, Jan
2017-01-01
Abstract The severity of liver disease is assessed by scoring systems, which include the conventional coagulation test prothrombin time-the international normalized ratio (PT-INR). However, PT-INR is not predictive of bleeding in liver disease and thromboelastometry (ROTEM) has been suggested to give a better overview of the coagulation system in these patients. It has now been suggested that coagulation as reflected by tromboelastomety may also be used for prognostic purposes. The objective of our study was to investigate whether thrombelastometry may discriminate the degree of liver insufficiency according to the scoring systems Child Pugh and Model for End-stage Liver Disease (MELD). Forty patients with chronic liver disease of different etiologies and stages were included in this observational cross-sectional study. The severity of liver disease was evaluated using the Child-Pugh score and the MELD score, and blood samples for biochemistry, conventional coagulation tests, and ROTEM were collected at the time of the final assessment for liver transplantation. Statistical comparisons for the studied parameters with scores of severity were made using Spearman correlation test and receiver-operating characteristic (ROC) curves. Spearman correlation coefficients indicated that the thromboelastometric parameters did not correlate with Child-Pugh or MELD scores. The ROC curves of the thromboelastometric parameters could not differentiate advanced stages from early stages of liver cirrhosis. Standard ROTEM cannot discriminate the stage of chronic liver disease in patients with severe chronic liver disease. PMID:28591054
Computer-aided diagnosis with textural features for breast lesions in sonograms.
Chen, Dar-Ren; Huang, Yu-Len; Lin, Sheng-Hsiung
2011-04-01
Computer-aided diagnosis (CAD) systems provided second beneficial support reference and enhance the diagnostic accuracy. This paper was aimed to develop and evaluate a CAD with texture analysis in the classification of breast tumors for ultrasound images. The ultrasound (US) dataset evaluated in this study composed of 1020 sonograms of region of interest (ROI) subimages from 255 patients. Two-view sonogram (longitudinal and transverse views) and four different rectangular regions were utilized to analyze each tumor. Six practical textural features from the US images were performed to classify breast tumors as benign or malignant. However, the textural features always perform as a high dimensional vector; high dimensional vector is unfavorable to differentiate breast tumors in practice. The principal component analysis (PCA) was used to reduce the dimension of textural feature vector and then the image retrieval technique was performed to differentiate between benign and malignant tumors. In the experiments, all the cases were sampled with k-fold cross-validation (k=10) to evaluate the performance with receiver operating characteristic (ROC) curve. The area (A(Z)) under the ROC curve for the proposed CAD system with the specific textural features was 0.925±0.019. The classification ability for breast tumor with textural information is satisfactory. This system differentiates benign from malignant breast tumors with a good result and is therefore clinically useful to provide a second opinion. Copyright © 2010 Elsevier Ltd. All rights reserved.
Park, Hyun Oh; Kim, Jong Woo; Kim, Sung Hwan; Moon, Seong Ho; Byun, Joung Hun; Kim, Ki Nyun; Yang, Jun Ho; Lee, Chung Eun; Jang, In Seok; Kang, Dong Hun; Kim, Seong Chun; Kang, Changwoo; Choi, Jun Young
2017-11-01
Early estimation of mortality risk in patients with trauma is essential. In this study, we evaluate the validity of the Emergency Trauma Score (EMTRAS) and Rapid Emergency Medicine Score (REMS) for predicting in-hospital mortality in patients with trauma. Furthermore, we compared the REMS and the EMTRAS with 2 other scoring systems: the Revised Trauma Score (RTS) and Injury Severity score (ISS).We performed a retrospective chart review of 6905 patients with trauma reported between July 2011 and June 2016 at a large national university hospital in South Korea. We analyzed the associations between patient characteristics, treatment course, and injury severity scoring systems (ISS, RTS, EMTRAS, and REMS) with in-hospital mortality. Discriminating power was compared between scoring systems using the areas under the curve (AUC) of receiver operating characteristic (ROC) curves.The overall in-hospital mortality rate was 3.1%. Higher EMTRAS and REMS scores were associated with hospital mortality (P < .001). The ROC curve demonstrated adequate discrimination (AUC = 0.957 for EMTRAS and 0.9 for REMS). After performing AUC analysis followed by Bonferroni correction for multiple comparisons, EMTRAS was significantly superior to REMS and ISS in predicting in-hospital mortality (P < .001), but not significantly different from the RTS (P = .057). The other scoring systems were not significantly different from each other.The EMTRAS and the REMS are simple, accurate predictors of in-hospital mortality in patients with trauma.
A method for identifying color vision deficiency malingering.
Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo
2017-03-01
To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.
Moreno-Torres, Luis Antonio; Hernández-Garduño, Adolfo Gabriel; Arellano-Valdés, Carmen Araceli; Salinas-Rodríguez, Aarón; Rubio-Perez, Nadina; Peláez-Ballestas, Ingris
2016-04-01
The aim of this study was to validate the paediatric Gait, Arms, Legs, Spine (pGALS) tool for Mexican Spanish to screen Mexican paediatric population for musculoskeletal (MSK) disorders. A cross-sectional study was performed in the Paediatric Hospital of the Mexican Social Security Institute in Guadalajara, Jalisco. The validation included children and adolescents aged 6-16 years, 87 patients with musculoskeletal disorders and 88 controls without musculoskeletal disorders. The cross-cultural validation followed the current published guidelines. The average pGALS administration time was 2.9 min (SD 0.54). The internal consistency score (Cronbach's α) was 0.90 (0.89 for inflammatory and 0.77 for non-inflammatory disorders) for MSK disorders, with a sensitivity of 97 % (95 % CI 92-99 %), a specificity of 93 % (95 % CI 86-97 %), a LR+ of 14.3, and a ROC curve of 0.95 (95 % CI 0.92-0.98 %). The inflammatory disorders group had a sensitivity of 97 % (95 % CI 86-99 %), a specificity of 93 % (95 % CI 86-97 %), a LR+ of 14.2, and a ROC curve of 0.95 % (95 % CI 0.91-0.99 %). The non-inflammatory disorders group had a sensitivity of 98 % (95 % CI 89-99 %), a specificity of 93 % (95 % CI 86-97 %), and a LR+ of 14.37, with a ROC curve of 0.95 % (95 % CI 0.92-0.98 %). pGALS is a valid screening tool, fast, easy to administer, and useful for detecting musculoskeletal disorders in Mexican children and adolescents.
Uesugi, Keriann H.; Niederdeppe, Jeff; Gay, Geri K.; Olson, Christine M.
2014-01-01
Abstract Background: Gaining more weight during pregnancy than is recommended by the Institute of Medicine is prevalent and contributes to the development of obesity in women. This article describes the development and use of e-Moms of Rochester (e-Moms Roc), an electronic intervention (e-intervention), to address this health issue in a socioeconomically diverse sample of pregnant women. Materials and Methods: Formative research in the form of intercept interviews, in-depth interviews, and focus groups was conducted to inform the design of the e-intervention. The Web site continuously tracked each participant's use of e-intervention features. Results: An e-intervention, including Web site and mobile phone components, was developed and implemented in a randomized control trial. Formative research informed the design. Participants in all arms accessed blogs, local resources, articles, frequently asked questions, and events. Participants in the intervention arms also accessed the weight gain tracker and diet and physical activity goal-setting tools. Overall, 80% of women logged into the Web site and used a tool or feature at least twice. Among those in the intervention arm, 70% used the weight gain tracker, but only 40% used the diet and physical activity goal-setting tools. Conclusions: To maximize and sustain potential usage of e-Moms Roc over time, the e-intervention included customized reminders, tailored content, and community features such as blogs and resources. Usage was comparable to those in other weight studies with young adults and higher than reported in a published study with pregnant women. This e-intervention specifically designed for pregnant women was used by the majority of women. PMID:25354350
Plasma urocortin in human systolic heart failure.
Ng, Leong L; Loke, Ian W; O'Brien, Russell J; Squire, Iain B; Davies, Joan E
2004-04-01
Urocortin (UCN), a member of the corticotrophin-releasing factor family, is expressed in heart, brain and gut. UCN has potent cardiostimulatory, cardioprotective, vasodilator and diuretic/natriuretic effects, and cardiac UCN expression is increased in heart failure (HF). In the present study, we investigated plasma levels of UCN in 119 patients with HF and 212 age- and gender-matched controls to clarify its relationship with gender and disease severity. UCN was elevated in HF [normal males, 19.5 (3.9-68.8) pmol/l and HF males, 50.2 (6.9-108.2) pmol/l, P < 0.0005; normal females, 14.2 (3.9-53.5) pmol/l and HF females, 21.8 (3.9-112.5) pmol/l, P < 0.001; values are medians (range)]. The relative increase was greater in males than females ( P < 0.03). UCN fell with increasing age, especially in HF patients ( r(s) = -0.56, P < 0.0005) and with increasing New York Heart Association (NYHA) class ( r(s) = -0.55, P < 0.0005). The fall in UCN levels with increasing NYHA class was reinforced by a significant correlation between UCN and ejection fraction ( r(s) = 0.45, P < 0.0005) in HF patients. Although receiver operating characteristic (ROC) curves for diagnosis of all HF cases yielded an area under the curve (AUC) of 0.76, ROC AUCs for patients with early HF (NYHA class I and II) were better (0.91). ROC AUCs for logistic models incorporating N-terminal probrain natriuretic peptide (N-BNP) and UCN were better than either peptide alone. In conclusion, plasma UCN is elevated in HF, especially in its early stages. Its decline with increasing HF severity may expedite disease progression due to diminished cardioprotective/anti-inflammatory effects. UCN measurement may also complement N-BNP in the diagnosis of early HF.
De Cicco, Concetta; Mariani, Luigi; Vedruccio, Clarbruno; Ricci, Carla; Balma, Massimo; Rotmensz, Nicole; Ferrari, Mahila Esmeralda; Autino, Elena; Trifirò, Giuseppe; Sacchini, Virgilio; Viale, Giuseppe; Paganelli, Giovanni
2006-01-01
There is a need for a cost-effective method to safely reduce the number of diagnostic procedures women undergo for breast cancer. We tested a new procedure for breast cancer diagnosis based on breast tissue response to low level electromagnetic incident waves. We tested 101 patients with suspicious palpable breast lesions detected by mammography or ultrasonography, who were scheduled to undergo an open biopsy. Using an electromagnetic field generator (tissue resonance interaction method probe [TRIMprob]), we passed the TRIMprob over the breast area and recorded the signal variation of one or more spectral lines (dB1, dB2, dB3). The results were compared with those of a control group as well as with pathology data obtained from excisional biopsy. No adverse effects of the test were observed. Pathology revealed 86 malignant breast cancers (72 invasive, 14 in situ) and 15 benign conditions. We achieved the best discrimination between normal breasts and lesions using dB1 (dB1 AUC-ROC = 0.8; dB2 AUC-ROC = 0.61; dB3 AUC-ROC = 0.76). With a specificity of 75% to 95%, the sensitivity ranged from 49% to 84%. Tumor or patient variables did not influence the results. The TRIMprob test was able to provide some degree of discrimination between normal breast tissue and lesions but not between benign and malignant lesions. The lack of influence of patient age and tumor size on test results might be advantageous in terms of early diagnosis in young women. These preliminary results need to be verified and extended in a preclinical-stage disease setting before clinical applicability can be envisaged.
Yu, Jihnhee; Yang, Luge; Vexler, Albert; Hutson, Alan D
2016-06-15
The receiver operating characteristic (ROC) curve is a popular technique with applications, for example, investigating an accuracy of a biomarker to delineate between disease and non-disease groups. A common measure of accuracy of a given diagnostic marker is the area under the ROC curve (AUC). In contrast with the AUC, the partial area under the ROC curve (pAUC) looks into the area with certain specificities (i.e., true negative rate) only, and it can be often clinically more relevant than examining the entire ROC curve. The pAUC is commonly estimated based on a U-statistic with the plug-in sample quantile, making the estimator a non-traditional U-statistic. In this article, we propose an accurate and easy method to obtain the variance of the nonparametric pAUC estimator. The proposed method is easy to implement for both one biomarker test and the comparison of two correlated biomarkers because it simply adapts the existing variance estimator of U-statistics. In this article, we show accuracy and other advantages of the proposed variance estimation method by broadly comparing it with previously existing methods. Further, we develop an empirical likelihood inference method based on the proposed variance estimator through a simple implementation. In an application, we demonstrate that, depending on the inferences by either the AUC or pAUC, we can make a different decision on a prognostic ability of a same set of biomarkers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Ibrahim, Tamer M; Bauer, Matthias R; Dörr, Alexander; Veyisoglu, Erdem; Boeckler, Frank M
2015-11-23
Recently, we have reported a systematic comparison of molecular preparation protocols (using MOE or Maestro) in combination with two docking tools (GOLD or Glide), employing our DEKOIS 2.0 benchmark sets. Herein, we demonstrate how comparable settings of data preparation protocols can affect the profile and AUC of pROC curves based on variations in chemotype enrichment. We show how the recognition of different classes of chemotypes can affect the docking performance, particularly in the early enrichment, and monitor changes in this recognition behavior based on score normalization and rescoring strategies. For this, we have developed "pROC-Chemotype", which is an automated protocol that matches and visualizes ligand chemotype information together with potency classes in the pROC profiles obtained by docking. This tool enhances the understanding of the influence of chemotype recognition in early enrichment, but also reveals trends of impaired recognition of chemotype classes at the end of the score-ordered rank. Identifying such issues helps to devise score-normalization strategies to overcome this potential bias in an intuitive manner. Furthermore, strong perturbations in chemotype ranking between different methods can help to identify the underlying reasons (e.g., changes in the protonation/tautomerization state). It also assists in the selection of appropriate scoring functions that are capable to retrieve more potent and diverse hits. In summary, we demonstrate how this new tool can be utilized to identify and highlight chemotype-specific behavior, e.g., in dataset preparation. This can help to overcome some chemistry-related bias in virtual screening campaigns. pROC-Chemotype is made freely available at www.dekois.com.
Cappon, Giacomo; Marturano, Francesca; Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni
2018-05-01
The standard formula (SF) used in bolus calculators (BCs) determines meal insulin bolus using "static" measurement of blood glucose concentration (BG) obtained by self-monitoring of blood glucose (SMBG) fingerprick device. Some methods have been proposed to improve efficacy of SF using "dynamic" information provided by continuous glucose monitoring (CGM), and, in particular, glucose rate of change (ROC). This article compares, in silico and in an ideal framework limiting the exposition to possibly confounding factors (such as CGM noise), the performance of three popular techniques devised for such a scope, that is, the methods of Buckingham et al (BU), Scheiner (SC), and Pettus and Edelman (PE). Using the UVa/Padova Type 1 diabetes simulator we generated data of 100 virtual subjects in noise-free, single-meal scenarios having different preprandial BG and ROC values. Meal insulin bolus was computed using SF, BU, SC, and PE. Performance was assessed with the blood glucose risk index (BGRI) on the 9 hours after meal. On average, BU, SC, and PE improve BGRI compared to SF. When BG is rapidly decreasing, PE obtains the best performance. In the other ROC scenarios, none of the considered methods prevails in all the preprandial BG conditions tested. Our study showed that, at least in the considered ideal framework, none of the methods to correct SF according to ROC is globally better than the others. Critical analysis of the results also suggests that further investigations are needed to develop more effective formulas to account for ROC information in BCs.
NASA Astrophysics Data System (ADS)
Abbey, Craig K.; Samuelson, Frank W.; Gallas, Brandon D.; Boone, John M.; Niklason, Loren T.
2013-03-01
The receiver operating characteristic (ROC) curve has become a common tool for evaluating diagnostic imaging technologies, and the primary endpoint of such evaluations is the area under the curve (AUC), which integrates sensitivity over the entire false positive range. An alternative figure of merit for ROC studies is expected utility (EU), which focuses on the relevant region of the ROC curve as defined by disease prevalence and the relative utility of the task. However if this measure is to be used, it must also have desirable statistical properties keep the burden of observer performance studies as low as possible. Here, we evaluate effect size and variability for EU and AUC. We use two observer performance studies recently submitted to the FDA to compare the EU and AUC endpoints. The studies were conducted using the multi-reader multi-case methodology in which all readers score all cases in all modalities. ROC curves from the study were used to generate both the AUC and EU values for each reader and modality. The EU measure was computed assuming an iso-utility slope of 1.03. We find mean effect sizes, the reader averaged difference between modalities, to be roughly 2.0 times as big for EU as AUC. The standard deviation across readers is roughly 1.4 times as large, suggesting better statistical properties for the EU endpoint. In a simple power analysis of paired comparison across readers, the utility measure required 36% fewer readers on average to achieve 80% statistical power compared to AUC.
Silva, Fabrício R; Vidotti, Vanessa G; Cremasco, Fernanda; Dias, Marcelo; Gomi, Edson S; Costa, Vital P
2013-01-01
To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.
Chang, Xiao-Yue; Yang, Yong; Jia, Xiao-Qing; Wang, Yuan; Peng, Li-Na; Ai, Xiao-Hong; Jiang, Cui-Ying; Guo, Jian-Hua; Wu, Ting-Ting
2016-03-01
The purpose of this study is to explore the correlation between serum dipeptidyl peptidase IV (DPPIV) and chronic obstructive pulmonary disease (COPD) at its various disease states, analyze its applications in the prediction and diagnosis of COPD and test the possibility of DPPIV as the serologic marker for COPD screening. Samples from 74 patients (42 cases with acute exacerbation of COPD or acute exacerbation COPD (AECOPD) and 32 cases with stable COPD) and 29 control subjects were collected in this study. Those patients with AECOPD were classified as COPD remission group if their clinical symptoms relieved after nonintravenous or oral hormone therapy for 7 ± 3 days. DPPIV concentration was measured by enzyme-linked immunosorbent assay, and the difference in serum concentration of DPPIV was compared among different groups. The correlation between DPPIV concentration and age, sex or smoking history was analyzed, and the diagnostic value of DPPIV was evaluated by receiver-operating characteristic (ROC) curve analysis. Serum DPPIV concentration was significantly lower in all COPD groups as compared with that in healthy control group (P < 0.001). Serum DPPIV concentration in AECOPD group was increased after treatment (P < 0.001). There was no significant correlation between DPPIV concentration and age, sex or smoking history (P > 0.05). ROC analysis indicated that serum DPPIV concentration in all groups showed a good diagnostic accuracy, especially in stable COPD and AECOPD groups. The area under the ROC curve values were 0.901 and 0.906, respectively, with a high specificity of 0.931 for both groups and a high sensitivity of 0.75 for stable COPD and 0.875 for AECOPD. Serum DPPIV concentration in patients with COPD is decreased significantly, and there is no correlation between serum DPPIV concentration and sex or age. Serum DPPIV not only is an independent predictive factor, but also of high value as a good serologic marker for the diagnosis of COPD. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Dodge, Hiroko H; Mattek, Nora; Gregor, Mattie; Bowman, Molly; Seelye, Adriana; Ybarra, Oscar; Asgari, Meysam; Kaye, Jeffrey A
2015-01-01
Detecting early signs of Alzheimer's disease (AD) and mild cognitive impairment (MCI) during the pre-symptomatic phase is becoming increasingly important for costeffective clinical trials and also for deriving maximum benefit from currently available treatment strategies. However, distinguishing early signs of MCI from normal cognitive aging is difficult. Biomarkers have been extensively examined as early indicators of the pathological process for AD, but assessing these biomarkers is expensive and challenging to apply widely among pre-symptomatic community dwelling older adults. Here we propose assessment of social markers, which could provide an alternative or complementary and ecologically valid strategy for identifying the pre-symptomatic phase leading to MCI and AD. The data came from a larger randomized controlled clinical trial (RCT), where we examined whether daily conversational interactions using remote video telecommunications software could improve cognitive functions of older adult participants. We assessed the proportion of words generated by participants out of total words produced by both participants and staff interviewers using transcribed conversations during the intervention trial as an indicator of how two people (participants and interviewers) interact with each other in one-on-one conversations. We examined whether the proportion differed between those with intact cognition and MCI, using first, generalized estimating equations with the proportion as outcome, and second, logistic regression models with cognitive status as outcome in order to estimate the area under ROC curve (ROC AUC). Compared to those with normal cognitive function, MCI participants generated a greater proportion of words out of the total number of words during the timed conversation sessions (p=0.01). This difference remained after controlling for participant age, gender, interviewer and time of assessment (p=0.03). The logistic regression models showed the ROC AUC of identifying MCI (vs. normals) was 0.71 (95% Confidence Interval: 0.54 - 0.89) when average proportion of word counts spoken by subjects was included univariately into the model. An ecologically valid social marker such as the proportion of spoken words produced during spontaneous conversations may be sensitive to transitions from normal cognition to MCI.
Differentiating constitutional thinness from anorexia nervosa in DSM 5 era.
Estour, Bruno; Marouani, Nesrine; Sigaud, Torrance; Lang, François; Fakra, Eric; Ling, Yiin; Diamondé, Aurélie; Minnion, James S; Galusca, Bogdan; Germain, Natacha
2017-10-01
Constitutional thinness (CT) is an underweight state characterized by normal menstruations and no change in feeding behaviour. Thinness is the only resemblance between Anorexia Nervosa (AN) and CT. Removal of amenorrhea from the new DSM 5 definition of AN might result in misdiagnosis between these two populations. The objective of this study was to compare CT, AN and Control subjects in terms of biological, anthropometric, and psychological markers in order to better distinguish AN from CT subjects. Body composition, nutritional markers, pituitary hormones, bone markers and psychological scores were evaluated in three groups of young women: fifty-six CT, forty restrictive-type AN and fifty-four Control subjects. For every marker, a receiver Operator Characteristics (ROC) curve was calculated to evaluate the accuracy of differentiation between AN and CT groups. For most studied parameters, CT subjects were similar to Controls but dramatically different from AN subjects. DEBQ Restrained Eating subscale score was identified by ROC data analysis as the only psychological parameter tested to successfully differentiate AN from CT. Free-T3 and Leptin were shown to be powerful markers to differentiate AN and CT populations as they were highly specific and sensitive ones. The exclusive use of psychological testing criteria is not always sufficient to differentiate AN and CT patients. Minimally, additional testing of Free T3 levels, which is cheap and widely accessible for general practitioners, should be completed to avoid misdiagnosis which could result in the implementation of ineffective treatment plans and social stigmatization for CT women. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wong, Adrian; Xiong, Yun-yun; Wang, Defeng; Lin, Shi; Chu, Winnie W C; Kwan, Pauline W K; Nyenhuis, David; Black, Sandra E; Wong, Ka Sing Lawrence; Mok, Vincent
2013-05-01
Vascular cognitive impairment (VCI) affects up to half of stroke survivors and predicts poor outcomes. Valid and reliable assessement for VCI is lacking, especially for the Chinese population. In 2005, the National Institute of Neurological Disorders and Stroke and Canadian Stroke Network (NINDS-CSN) Harmonisation workshop proposed a set of three neuropsychology protocols for VCI evaluation. This paper is to introduce the protocol design and to report the psychometric properties of the Chinese NINDS-CSN VCI protocols. Fifty patients with mild stroke (mean National Institute of Health Stroke Scale 2.2 (SD=3.2)) and 50 controls were recruited. The NINDS-CSN VCI protocols were adapted into Chinese. We assessed protocols' (1) external validity, defined by how well the protocol summary scores differentiated patients from controls using receiver operating characteristics (ROC) curve analysis; (2) concurrent validity, by correlations with functional measures including Stroke Impact Scale memory score and Chinese Disability Assessment for Dementia; (3) internal consistency; and (4) ease of administration. All three protocols differentiated patients from controls (area under ROC for the three protocols between 0.77 to 0.79, p<0.001), and significantly correlated with the functional measures (Pearson r ranged from 0.37 to 0.51). A cut-off of 19/20 on MMSE identified only one-tenth of patients classified as impaired on the 5-min protocol. Cronbach's α across the four cognitive domains of the 60-min protocol was 0.78 for all subjects and 0.76 for stroke patients. The Chinese NINDS-CSN VCI protocols are valid and reliable for cognitive assessment in Chinese patients with mild stroke.
NASA Astrophysics Data System (ADS)
Chen, Xue; Li, Xiaohui; Yu, Xin; Chen, Deying; Liu, Aichun
2018-01-01
Diagnosis of malignancies is a challenging clinical issue. In this work, we present quick and robust diagnosis and discrimination of lymphoma and multiple myeloma (MM) using laser-induced breakdown spectroscopy (LIBS) conducted on human serum samples, in combination with chemometric methods. The serum samples collected from lymphoma and MM cancer patients and healthy controls were deposited on filter papers and ablated with a pulsed 1064 nm Nd:YAG laser. 24 atomic lines of Ca, Na, K, H, O, and N were selected for malignancy diagnosis. Principal component analysis (PCA), linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and k nearest neighbors (kNN) classification were applied to build the malignancy diagnosis and discrimination models. The performances of the models were evaluated using 10-fold cross validation. The discrimination accuracy, confusion matrix and receiver operating characteristic (ROC) curves were obtained. The values of area under the ROC curve (AUC), sensitivity and specificity at the cut-points were determined. The kNN model exhibits the best performances with overall discrimination accuracy of 96.0%. Distinct discrimination between malignancies and healthy controls has been achieved with AUC, sensitivity and specificity for healthy controls all approaching 1. For lymphoma, the best discrimination performance values are AUC = 0.990, sensitivity = 0.970 and specificity = 0.956. For MM, the corresponding values are AUC = 0.986, sensitivity = 0.892 and specificity = 0.994. The results show that the serum-LIBS technique can serve as a quick, less invasive and robust method for diagnosis and discrimination of human malignancies.
Ultrasound biomicroscopy and iris pigment dispersion: a case--control study.
Mora, P; Sangermani, C; Ghirardini, S; Carta, A; Ungaro, N; Gandolfi, Sa
2010-04-01
The study involved eyes affected by pigment dispersion syndrome (PDS) or pigmentary glaucoma (PG) investigated by ultrasound biomicroscopy (UBM). Different irido-corneal parameters were assessed and compared with those from healthy controls. The aim was to investigate the capacity of the UBM in differentiating the cases and, potentially, in confirming the pathogenic mechanisms. Patients with a first diagnosis of PDS or PG were included. A cohort of healthy volunteers matched for sex, age and refractive errors was recruited. All underwent UBM examination: the following parameters were assessed in relaxed and stimulated accommodative state in one eye: iris-lens contact (ILC), irido-corneal angle (ICA) and iris concavity (IC). A receiver operating characteristic (ROC) analysis assessed the ability of UBM to discriminate between subjects with and without PDS/PG. There were 24 eyes in the case group: four diagnosed as PG and the remaining 20 as PDS. There were 25 eyes in the control group. The two groups were statistically superimposable except for baseline intraocular pressure, which was higher in the case group (p=0.0001). All UBM parameters were statistically different between the two groups. ICA in near vision was the best-performing parameter, reaching a sensitivity (=specificity) of 0.875 with a cut-off at 53.0 degrees . The second most sensitive parameter was IC, still in near vision. All UBM parameters examined were statistically different between the two groups. ROC analysis showed ICA and IC in near vision to be the most discriminatory parameters. This evidence confirms the importance of iris movements in inducing the particular features of PDS/PG.
Brain magnetic resonance imaging CO2 stress testing in adolescent postconcussion syndrome.
Mutch, W Alan C; Ellis, Michael J; Ryner, Lawrence N; Ruth Graham, M; Dufault, Brenden; Gregson, Brian; Hall, Thomas; Bunge, Martin; Essig, Marco; Fisher, Joseph A; Duffin, James; Mikulis, David J
2016-09-01
OBJECT A neuroimaging assessment tool to visualize global and regional impairments in cerebral blood flow (CBF) and cerebrovascular responsiveness in individual patients with concussion remains elusive. Here the authors summarize the safety, feasibility, and results of brain CO2 stress testing in adolescents with postconcussion syndrome (PCS) and healthy controls. METHODS This study was approved by the Biomedical Research Ethics Board at the University of Manitoba. Fifteen adolescents with PCS and 17 healthy control subjects underwent anatomical MRI, pseudo-continuous arterial spin labeling MRI, and brain stress testing using controlled CO2 challenge and blood oxygen level-dependent (BOLD) MRI. Post hoc processing was performed using statistical parametric mapping to determine voxel-by-voxel regional resting CBF and cerebrovascular responsiveness of the brain to the CO2 stimulus (increase in BOLD signal) or the inverse (decrease in BOLD signal). Receiver operating characteristic (ROC) curves were generated to compare voxel counts categorized by control (0) or PCS (1). RESULTS Studies were well tolerated without any serious adverse events. Anatomical MRI was normal in all study participants. No differences in CO2 stimuli were seen between the 2 participant groups. No group differences in global mean CBF were detected between PCS patients and healthy controls. Patient-specific differences in mean regional CBF and CO2 BOLD responsiveness were observed in all PCS patients. The ROC curve analysis for brain regions manifesting a voxel response greater than and less than the control atlas (that is, abnormal voxel counts) produced an area under the curve of 0.87 (p < 0.0001) and 0.80 (p = 0.0003), respectively, consistent with a clinically useful predictive model. CONCLUSIONS Adolescent PCS is associated with patient-specific abnormalities in regional mean CBF and BOLD cerebrovascular responsiveness that occur in the setting of normal global resting CBF. Future prospective studies are warranted to examine the utility of brain MRI CO2 stress testing in the longitudinal assessment of acute sports-related concussion and PCS.
Ares I-X: On the Threshold of Exploration
NASA Technical Reports Server (NTRS)
Davis, Stephan R.; Askins, Bruce
2009-01-01
Ares I-X, the first flight of the Ares I crew launch vehicle, is less than a year from launch. Ares I-X will test the flight characteristics of Ares I from liftoff to first stage separation and recovery. The flight also will demonstrate the computer hardware and software (avionics) needed to control the vehicle; deploy the parachutes that allow the first stage booster to land in the ocean safely; measure and control how much the rocket rolls during flight; test and measure the effects of first stage separation; and develop and try out new ground handling and rocket stacking procedures in the Vehicle Assembly Building (VAB) and first stage recovery procedures at Kennedy Space Center (KSC) in Florida. All Ares I-X major elements have completed their critical design reviews, and are nearing final fabrication. The first stage--four-segment solid rocket booster from the Space Shuttle inventory--incorporates new simulated forward structures to match the Ares I five-segment booster. The upper stage, Orion crew module, and launch abort system will comprise simulator hardware that incorporates developmental flight instrumentation for essential data collection during the mission. The upper stage simulator consists of smaller cylindrical segments, which were transported to KSC in fall 2008. The crew module and launch abort system simulator were shipped in December 2008. The first stage hardware, active roll control system (RoCS), and avionics components will be delivered to KSC in 2009. This paper will provide detailed statuses of the Ares I-X hardware elements as NASA's Constellation Program prepares for this first flight of a new exploration era in the summer of 2009.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Islam, Md. Shafiqul, E-mail: shafique@eng.ukm.my; Hannan, M.A., E-mail: hannan@eng.ukm.my; Basri, Hassan
Highlights: • Solid waste bin level detection using Dynamic Time Warping (DTW). • Gabor wavelet filter is used to extract the solid waste image features. • Multi-Layer Perceptron classifier network is used for bin image classification. • The classification performance evaluated by ROC curve analysis. - Abstract: The increasing requirement for Solid Waste Management (SWM) has become a significant challenge for municipal authorities. A number of integrated systems and methods have introduced to overcome this challenge. Many researchers have aimed to develop an ideal SWM system, including approaches involving software-based routing, Geographic Information Systems (GIS), Radio-frequency Identification (RFID), or sensormore » intelligent bins. Image processing solutions for the Solid Waste (SW) collection have also been developed; however, during capturing the bin image, it is challenging to position the camera for getting a bin area centralized image. As yet, there is no ideal system which can correctly estimate the amount of SW. This paper briefly discusses an efficient image processing solution to overcome these problems. Dynamic Time Warping (DTW) was used for detecting and cropping the bin area and Gabor wavelet (GW) was introduced for feature extraction of the waste bin image. Image features were used to train the classifier. A Multi-Layer Perceptron (MLP) classifier was used to classify the waste bin level and estimate the amount of waste inside the bin. The area under the Receiver Operating Characteristic (ROC) curves was used to statistically evaluate classifier performance. The results of this developed system are comparable to previous image processing based system. The system demonstration using DTW with GW for feature extraction and an MLP classifier led to promising results with respect to the accuracy of waste level estimation (98.50%). The application can be used to optimize the routing of waste collection based on the estimated bin level.« less
ERIC Educational Resources Information Center
Starns, Jeffrey J.; Pazzaglia, Angela M.; Rotello, Caren M.; Hautus, Michael J.; Macmillan, Neil A.
2013-01-01
Source memory zROC slopes change from below 1 to above 1 depending on which source gets the strongest learning. This effect has been attributed to memory processes, either in terms of a threshold source recollection process or changes in the variability of continuous source evidence. We propose 2 decision mechanisms that can produce the slope…
Thomas H. Epps; Daniel R. Hitchcock; Anand D. Jayakaran; Drake R. Loflin; Thomas M. Williams; Devendra M. Amatya
2013-01-01
Hydrologic monitoring was conducted in two first-order lower coastal plain watersheds in South Carolina, United States, a region with increasing growth and land use change. Storm events over a three-year period were analyzed for direct runoff coefficients (ROC) and the total storm response (TSR) as percent rainfall. ROC calculations utilized an empirical hydrograph...
Automatic Mexico Gulf Oil Spill Detection from Radarsat-2 SAR Satellite Data Using Genetic Algorithm
NASA Astrophysics Data System (ADS)
Marghany, Maged
2016-10-01
In this work, a genetic algorithm is exploited for automatic detection of oil spills of small and large size. The route is achieved using arrays of RADARSAT-2 SAR ScanSAR Narrow single beam data obtained in the Gulf of Mexico. The study shows that genetic algorithm has automatically segmented the dark spot patches related to small and large oil spill pixels. This conclusion is confirmed by the receiveroperating characteristic (ROC) curve and ground data which have been documented. The ROC curve indicates that the existence of oil slick footprints can be identified with the area under the curve between the ROC curve and the no-discrimination line of 90%, which is greater than that of other surrounding environmental features. The small oil spill sizes represented 30% of the discriminated oil spill pixels in ROC curve. In conclusion, the genetic algorithm can be used as a tool for the automatic detection of oil spills of either small or large size and the ScanSAR Narrow single beam mode serves as an excellent sensor for oil spill patterns detection and surveying in the Gulf of Mexico.
Inflammatory Asthma Phenotype Discrimination Using an Electronic Nose Breath Analyzer.
Plaza, V; Crespo, A; Giner, J; Merino, J L; Ramos-Barbón, D; Mateus, E F; Torrego, A; Cosio, B G; Agustí, A; Sibila, O
2015-01-01
Patients with persistent asthma have different inflammatory phenotypes. The electronic nose is a new technology capable of distinguishing volatile organic compound (VOC) breath-prints in exhaled breath. The aim of the study was to investigate the capacity of electronic nose breath-print analysis to discriminate between different inflammatory asthma phenotypes (eosinophilic, neutrophilic, paucigranulocytic) determined by induced sputum in patients with persistent asthma. Fifty-two patients with persistent asthma were consecutively included in a cross-sectional proof-of-concept study. Inflammatory asthma phenotypes (eosinophilic, neutrophilic and paucigranulocytic) were recognized by inflammatory cell counts in induced sputum. VOC breath-prints were analyzed using the electronic nose Cyranose 320 and assessed by discriminant analysis on principal component reduction, resulting in cross-validated accuracy values. Receiver operating characteristic (ROC) curves were calculated. VOC breath-prints were different in eosinophilic asthmatics compared with both neutrophilic asthmatics (accuracy 73%; P=.008; area under ROC, 0.92) and paucigranulocytic asthmatics (accuracy 74%; P=.004; area under ROC, 0.79). Likewise, neutrophilic and paucigranulocytic breath-prints were also different (accuracy 89%; P=.001; area under ROC, 0.88). An electronic nose can discriminate inflammatory phenotypes in patients with persistent asthma in a regular clinical setting. ClinicalTrials.gov identifier: NCT02026336.
Weng, Jingxia; Jia, Huichao; Wu, Bing; Pan, Bingcai
2018-01-01
Ozonation is a promising option to treat reverse osmosis concentrate (ROC). However, a systematic understanding and assessment of ozonation on toxicity reduction is insufficient. In this study, ROC sampled from a typical industrial park wastewater treatment plant of China was fractionated into hydrophobic acid (HOA), hydrophobic base (HOB), hydrophobic neutral (HON), and hydrophilic fraction (HI). Systematic bioassays covering bacteria, algae, fish, and human cell lines were conducted to reveal the role of ozonation in toxicity variation of the four ROC fractions. HOA in the raw ROC exhibited the highest toxicity, followed by HON and HI. Ozonation significantly reduced total organic carbon (TOC) and UV 254 values in HOA, HON, and HI and their toxicity except in HOB. Correlation analysis indicated that chemical data (TOC and UV 254 ) of HOA and HON correlated well with their toxicities; however, poor correlations were observed for HOB and HI, suggesting that a battery of toxicity assays is necessary. This study indicates that TOC reduction during ozonation could not fully reflect the toxicity issue, and toxicity assessment is required in conjunction with the chemical data to evaluate the effectiveness of ozonation. Copyright © 2017 Elsevier Ltd. All rights reserved.
An extension of the receiver operating characteristic curve and AUC-optimal classification.
Takenouchi, Takashi; Komori, Osamu; Eguchi, Shinto
2012-10-01
While most proposed methods for solving classification problems focus on minimization of the classification error rate, we are interested in the receiver operating characteristic (ROC) curve, which provides more information about classification performance than the error rate does. The area under the ROC curve (AUC) is a natural measure for overall assessment of a classifier based on the ROC curve. We discuss a class of concave functions for AUC maximization in which a boosting-type algorithm including RankBoost is considered, and the Bayesian risk consistency and the lower bound of the optimum function are discussed. A procedure derived by maximizing a specific optimum function has high robustness, based on gross error sensitivity. Additionally, we focus on the partial AUC, which is the partial area under the ROC curve. For example, in medical screening, a high true-positive rate to the fixed lower false-positive rate is preferable and thus the partial AUC corresponding to lower false-positive rates is much more important than the remaining AUC. We extend the class of concave optimum functions for partial AUC optimality with the boosting algorithm. We investigated the validity of the proposed method through several experiments with data sets in the UCI repository.
Mutations in a new Arabidopsis cyclophilin disrupt its interaction with protein phosphatase 2A
NASA Technical Reports Server (NTRS)
Jackson, K.; Soll, D.; Evans, M. L. (Principal Investigator)
1999-01-01
The heterotrimeric protein phosphatase 2A (PP2A) is a component of multiple signaling pathways in eukaryotes. Disruption of PP2A activity in Arabidopsis is known to alter auxin transport and growth response pathways. We demonstrated that the regulatory subunit A of an Arabidopsis PP2A interacts with a novel cyclophilin, ROC7. The gene for this cyclophilin encodes a protein that contains a unique 30-amino acid extension at the N-terminus, which distinguishes the gene product from all previously identified Arabidopsis cyclophilins. Altered forms of ROC7 cyclophilin with mutations in the conserved DENFKL domain did not bind to PP2A. Unlike protein phosphatase 2B, PP2A activity in Arabidopsis extracts was not affected by the presence of the cyclophilin-binding molecule cyclosporin. The ROC7 transcript was expressed to high levels in all tissues tested. Expression of an ROC7 antisense transcript gave rise to increased root growth. These results indicate that cyclophilin may have a role in regulating PP2A activity, by a mechanism that differs from that employed for cyclophilin regulation of PP2B.
Galizia, Gennaro; Lieto, Eva; Auricchio, Annamaria; Cardella, Francesca; Mabilia, Andrea; Diana, Anna; Castellano, Paolo; De Vita, Ferdinando; Orditura, Michele
2017-01-01
In gastric cancer, the current AJCC numeric-based lymph node staging does not provide information on the anatomical extent of the disease and lymphadenectomy. A new anatomical location-based node staging, proposed by Choi, has shown better prognostic performance, thus soliciting Western world validation. Data from 284 gastric cancers undergoing radical surgery at the Second University of Naples from 2000 to 2014 were reviewed. The lymph nodes were reclassified into three groups (lesser and greater curvature, and extraperigastric nodes); presence of any metastatic lymph node in a given group was considered positive, prompting a new N and TNM stage classification. Receiver-operating-characteristic (ROC) curves for censored survival data and bootstrap methods were used to compare the capability of the two models to predict tumor recurrence. More than one third of node positive patients were reclassified into different N and TNM stages by the new system. Compared to the current staging system, the new classification significantly correlated with tumor recurrence rates and displayed improved indices of prognostic performance, such as the Bayesian information criterion and the Harrell C-index. Higher values at survival ROC analysis demonstrated a significantly better stratification of patients by the new system, mostly in the early phase of the follow-up, with a worse prognosis in more advanced new N stages, despite the same current N stage. This study suggests that the anatomical location-based classification of lymph node metastasis may be an important tool for gastric cancer prognosis and should be considered for future revision of the TNM staging system.
Optimizing area under the ROC curve using semi-supervised learning
Wang, Shijun; Li, Diana; Petrick, Nicholas; Sahiner, Berkman; Linguraru, Marius George; Summers, Ronald M.
2014-01-01
Receiver operating characteristic (ROC) analysis is a standard methodology to evaluate the performance of a binary classification system. The area under the ROC curve (AUC) is a performance metric that summarizes how well a classifier separates two classes. Traditional AUC optimization techniques are supervised learning methods that utilize only labeled data (i.e., the true class is known for all data) to train the classifiers. In this work, inspired by semi-supervised and transductive learning, we propose two new AUC optimization algorithms hereby referred to as semi-supervised learning receiver operating characteristic (SSLROC) algorithms, which utilize unlabeled test samples in classifier training to maximize AUC. Unlabeled samples are incorporated into the AUC optimization process, and their ranking relationships to labeled positive and negative training samples are considered as optimization constraints. The introduced test samples will cause the learned decision boundary in a multidimensional feature space to adapt not only to the distribution of labeled training data, but also to the distribution of unlabeled test data. We formulate the semi-supervised AUC optimization problem as a semi-definite programming problem based on the margin maximization theory. The proposed methods SSLROC1 (1-norm) and SSLROC2 (2-norm) were evaluated using 34 (determined by power analysis) randomly selected datasets from the University of California, Irvine machine learning repository. Wilcoxon signed rank tests showed that the proposed methods achieved significant improvement compared with state-of-the-art methods. The proposed methods were also applied to a CT colonography dataset for colonic polyp classification and showed promising results.1 PMID:25395692
Optimizing area under the ROC curve using semi-supervised learning.
Wang, Shijun; Li, Diana; Petrick, Nicholas; Sahiner, Berkman; Linguraru, Marius George; Summers, Ronald M
2015-01-01
Receiver operating characteristic (ROC) analysis is a standard methodology to evaluate the performance of a binary classification system. The area under the ROC curve (AUC) is a performance metric that summarizes how well a classifier separates two classes. Traditional AUC optimization techniques are supervised learning methods that utilize only labeled data (i.e., the true class is known for all data) to train the classifiers. In this work, inspired by semi-supervised and transductive learning, we propose two new AUC optimization algorithms hereby referred to as semi-supervised learning receiver operating characteristic (SSLROC) algorithms, which utilize unlabeled test samples in classifier training to maximize AUC. Unlabeled samples are incorporated into the AUC optimization process, and their ranking relationships to labeled positive and negative training samples are considered as optimization constraints. The introduced test samples will cause the learned decision boundary in a multidimensional feature space to adapt not only to the distribution of labeled training data, but also to the distribution of unlabeled test data. We formulate the semi-supervised AUC optimization problem as a semi-definite programming problem based on the margin maximization theory. The proposed methods SSLROC1 (1-norm) and SSLROC2 (2-norm) were evaluated using 34 (determined by power analysis) randomly selected datasets from the University of California, Irvine machine learning repository. Wilcoxon signed rank tests showed that the proposed methods achieved significant improvement compared with state-of-the-art methods. The proposed methods were also applied to a CT colonography dataset for colonic polyp classification and showed promising results.
Knowledge-Based Methods To Train and Optimize Virtual Screening Ensembles
2016-01-01
Ensemble docking can be a successful virtual screening technique that addresses the innate conformational heterogeneity of macromolecular drug targets. Yet, lacking a method to identify a subset of conformational states that effectively segregates active and inactive small molecules, ensemble docking may result in the recommendation of a large number of false positives. Here, three knowledge-based methods that construct structural ensembles for virtual screening are presented. Each method selects ensembles by optimizing an objective function calculated using the receiver operating characteristic (ROC) curve: either the area under the ROC curve (AUC) or a ROC enrichment factor (EF). As the number of receptor conformations, N, becomes large, the methods differ in their asymptotic scaling. Given a set of small molecules with known activities and a collection of target conformations, the most resource intense method is guaranteed to find the optimal ensemble but scales as O(2N). A recursive approximation to the optimal solution scales as O(N2), and a more severe approximation leads to a faster method that scales linearly, O(N). The techniques are generally applicable to any system, and we demonstrate their effectiveness on the androgen nuclear hormone receptor (AR), cyclin-dependent kinase 2 (CDK2), and the peroxisome proliferator-activated receptor δ (PPAR-δ) drug targets. Conformations that consisted of a crystal structure and molecular dynamics simulation cluster centroids were used to form AR and CDK2 ensembles. Multiple available crystal structures were used to form PPAR-δ ensembles. For each target, we show that the three methods perform similarly to one another on both the training and test sets. PMID:27097522
Estimating the relative utility of screening mammography.
Abbey, Craig K; Eckstein, Miguel P; Boone, John M
2013-05-01
The concept of diagnostic utility is a fundamental component of signal detection theory, going back to some of its earliest works. Attaching utility values to the various possible outcomes of a diagnostic test should, in principle, lead to meaningful approaches to evaluating and comparing such systems. However, in many areas of medical imaging, utility is not used because it is presumed to be unknown. In this work, we estimate relative utility (the utility benefit of a detection relative to that of a correct rejection) for screening mammography using its known relation to the slope of a receiver operating characteristic (ROC) curve at the optimal operating point. The approach assumes that the clinical operating point is optimal for the goal of maximizing expected utility and therefore the slope at this point implies a value of relative utility for the diagnostic task, for known disease prevalence. We examine utility estimation in the context of screening mammography using the Digital Mammographic Imaging Screening Trials (DMIST) data. We show how various conditions can influence the estimated relative utility, including characteristics of the rating scale, verification time, probability model, and scope of the ROC curve fit. Relative utility estimates range from 66 to 227. We argue for one particular set of conditions that results in a relative utility estimate of 162 (±14%). This is broadly consistent with values in screening mammography determined previously by other means. At the disease prevalence found in the DMIST study (0.59% at 365-day verification), optimal ROC slopes are near unity, suggesting that utility-based assessments of screening mammography will be similar to those found using Youden's index.
Bayesian semiparametric estimation of covariate-dependent ROC curves
Rodríguez, Abel; Martínez, Julissa C.
2014-01-01
Receiver operating characteristic (ROC) curves are widely used to measure the discriminating power of medical tests and other classification procedures. In many practical applications, the performance of these procedures can depend on covariates such as age, naturally leading to a collection of curves associated with different covariate levels. This paper develops a Bayesian heteroscedastic semiparametric regression model and applies it to the estimation of covariate-dependent ROC curves. More specifically, our approach uses Gaussian process priors to model the conditional mean and conditional variance of the biomarker of interest for each of the populations under study. The model is illustrated through an application to the evaluation of prostate-specific antigen for the diagnosis of prostate cancer, which contrasts the performance of our model against alternative models. PMID:24174579
Advanced Communication and Control Solutions of Distributed Energy Resources (DER)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asgeirsson, Haukur; Seguin, Richard; Sherding, Cameron
2007-01-10
This report covers work performed in Phase II of a two phase project whose objective was to demonstrate the aggregation of multiple Distributed Energy Resources (DERs) and to offer them into the energy market. The Phase I work (DE-FC36-03CH11161) created an integrated, but distributed, system and procedures to monitor and control multiple DERs from numerous manufacturers connected to the electric distribution system. Procedures were created which protect the distribution network and personnel that may be working on the network. Using the web as the communication medium for control and monitoring of the DERs, the integration of information and security wasmore » accomplished through the use of industry standard protocols such as secure SSL,VPN and ICCP. The primary objective of Phase II was to develop the procedures for marketing the power of the Phase I aggregated DERs in the energy market, increase the number of DER units, and implement the marketing procedures (interface with ISOs) for the DER generated power. The team partnered with the Midwest Independent System Operator (MISO), the local ISO, to address the energy market and demonstrate the economic dispatch of DERs in response to market signals. The selection of standards-based communication technologies offers the ability of the system to be deployed and integrated with other utilities’ resources. With the use of a data historian technology to facilitate the aggregation, the developed algorithms and procedures can be verified, audited, and modified. The team has demonstrated monitoring and control of multiple DERs as outlined in phase I report including procedures to perform these operations in a secure and safe manner. In Phase II, additional DER units were added. We also expanded on our phase I work to enhance communication security and to develop the market model of having DERs, both customer and utility owned, participate in the energy market. We are proposing a two-part DER energy market model--a utility need business model and an independent energy aggregator-business model. The approach of developing two group models of DER energy participation in the market is unique. The Detroit Edison (DECo, Utility)-led team includes: DTE Energy Technologies (Dtech, DER provider), Electrical Distribution Design (EDD, Virginia Tech company supporting EPRI’s Distribution Engineering Workstation, DEW), Systems Integration Specialists Company (SISCO, economic scheduling and real-time protocol integrator), and OSIsoft (PI software system for managing real-time information). This team is focused on developing the application engineering, including software systems necessary for DER’s integration, control and sale into the market place. Phase II Highlights Installed and tested an ICCP link with SSL (security) between DECo, the utility, and DTE Energy Technologies (DTECH), the aggregator, making DER data available to the utility for both monitoring and control. Installed and tested PI process book with circuit & DER operational models for DECo SOC/ROC operator’s use for monitoring of both utility circuit and customer DER parameters. The PI Process Book models also included DER control for the DECo SOC/ROC operators, which was tested and demonstrated control. The DER Tagging and Operating Procedures were developed, which allowed that control to be done in a safe manner, were modified for required MOC/MISO notification procedures. The Distribution Engineering Workstation (DEW) was modified to include temperature normalized load research statistics, using a 30 hour day-ahead weather feed. This allowed day-ahead forecasting of the customer load profile and the entire circuit to determine overload and low voltage problems. This forecast at the point of common coupling was passed to DTech DR SOC for use in their economic dispatch algorithm. Standard Work Instructions were developed for DER notification, sale, and operation into the MISO market. A software mechanism consisting of a suite of new and revised functionality was developed that integrated with the local ISO such that offers can be made electronically without human intervention. A suite of software was developed by DR SOC enabling DER usage in real time and day-ahead: Generation information file exchange with PI and the utility power flow A utility day-ahead information file Energy Offer Web Service Market Result Web Service Real-Time Meter Data Web Service Real-Time Notification Web Service Registered over 20 DER with MISO in Demand Response Market and demonstrated electronic sale to MISO.« less
An Analysis of the Navy Manpower, Personnel, Training and Education Architecture
2017-03-01
the courses offered on the Navy 11 Education and Training Command (NETC) Learning Management System (LMS), better known as “E-Learning,” are... Training ,” offers a trimmed down version of the Defense Manpower Course offered at the Naval Postgraduate School (NPS). None fully satisfy training ...Environments (ROC/POE). • “ Training requirements are generated by customer organizations (COCOM’s, Type Commanders, Enterprises, Agencies, and other
Latest generation of ASICs for photodetector readout
NASA Astrophysics Data System (ADS)
Seguin-Moreau, N.
2013-08-01
The OMEGA microelectronics group has designed a new generation of multichannel integrated circuits, the "ROC" family, in AustrianMicroSystem (AMS) SiGe 0.35 μm technology to read out signals from various families of photodetectors. The chip named MAROC (standing for Multi Anode ReadOut Chip) has been designed to read out MultiAnode Photomultipliers (MAPMT), Photomultiplier ARray In SiGe ReadOut Chip (PARISROC) to read out Photomultipliers (PMTs) and SiPM Integrated ReadOut Chip (SPIROC) to readout Silicon PhotoMultiplier (SiPM) detectors and which was the first ASIC to do so. The three of them fulfill the stringent requirements of the future photodetectors, in particular in terms of low noise, radiation hardness, large dynamic range, high density and high speed while keeping low power thanks to the SiGe technology. These multi-channel ASICs are real System on Chip (SoC) as they provide charge, time and photon-counting information which are digitized internally. Their complexity and versatility enable innovative frontier detectors and also cover spin off of these detectors in adjacent fields such as medical or material imaging as well as smart detectors. In this presentation, the three ASIC architectures and test results will be described to give a general panorama of the "ROC" chips.
Classifying Volcanic Activity Using an Empirical Decision Making Algorithm
NASA Astrophysics Data System (ADS)
Junek, W. N.; Jones, W. L.; Woods, M. T.
2012-12-01
Detection and classification of developing volcanic activity is vital to eruption forecasting. Timely information regarding an impending eruption would aid civil authorities in determining the proper response to a developing crisis. In this presentation, volcanic activity is characterized using an event tree classifier and a suite of empirical statistical models derived through logistic regression. Forecasts are reported in terms of the United States Geological Survey (USGS) volcano alert level system. The algorithm employs multidisciplinary data (e.g., seismic, GPS, InSAR) acquired by various volcano monitoring systems and source modeling information to forecast the likelihood that an eruption, with a volcanic explosivity index (VEI) > 1, will occur within a quantitatively constrained area. Logistic models are constructed from a sparse and geographically diverse dataset assembled from a collection of historic volcanic unrest episodes. Bootstrapping techniques are applied to the training data to allow for the estimation of robust logistic model coefficients. Cross validation produced a series of receiver operating characteristic (ROC) curves with areas ranging between 0.78-0.81, which indicates the algorithm has good predictive capabilities. The ROC curves also allowed for the determination of a false positive rate and optimum detection for each stage of the algorithm. Forecasts for historic volcanic unrest episodes in North America and Iceland were computed and are consistent with the actual outcome of the events.
Ruscito, Ilary; Cacsire Castillo-Tong, Dan; Vergote, Ignace; Ignat, Iulia; Stanske, Mandy; Vanderstichele, Adriaan; Ganapathi, Ram N; Glajzer, Jacek; Kulbe, Hagen; Trillsch, Fabian; Mustea, Alexander; Kreuzinger, Caroline; Benedetti Panici, Pierluigi; Gourley, Charlie; Gabra, Hani; Kessler, Mirjana; Sehouli, Jalid; Darb-Esfahani, Silvia; Braicu, Elena Ioana
2017-07-01
High-grade serous ovarian cancer (HGSOC) causes 80% of all ovarian cancer (OC) deaths. In this setting, the role of cancer stem-like cells (CSCs) is still unclear. In particular, the evolution of CSC biomarkers from primary (pOC) to recurrent (rOC) HGSOCs is unknown. Aim of this study was to investigate changes in CD133 and aldehyde dehydrogenase-1 (ALDH1) CSC biomarker expression in pOC and rOC HGSOCs. Two-hundred and twenty-four pOC and rOC intrapatient paired tissue samples derived from 112 HGSOC patients were evaluated for CD133 and ALDH1 expression using immunohistochemistry (IHC); pOCs and rOCs were compared for CD133 and/or ALDH1 levels. Expression profiles were also correlated with patients' clinicopathological and survival data. Some 49.1% of the patient population (55/112) and 37.5% (42/112) pOCs were CD133+ and ALDH1+ respectively. CD133+ and ALDH1+ samples were detected in 33.9% (38/112) and 36.6% (41/112) rOCs. CD133/ALDH1 coexpression was observed in 23.2% (26/112) and 15.2% (17/112) of pOCs and rOCs respectively. Pairwise analysis showed a significant shift of CD133 staining from higher (pOCs) to lower expression levels (rOCs) (p < 0.0001). Furthermore, all CD133 + pOC patients were International Federation of Gynaecology and Obstetrics (FIGO)-stage III/IV (p < 0.0001) and had significantly worse progression-free interval (PFI) (p = 0.04) and overall survival (OS) (p = 0.02). On multivariate analysis, CD133/ALDH1 coexpression in pOCs was identified as independent prognostic factor for PFI (HR: 1.64; 95% CI: 1.03-2.60; p = 0.036) and OS (HR: 1.71; 95% CI: 1.01-2.88; p = 0.045). Analysis on 52 pts patients with known somatic BRCA status revealed that BRCA mutations did not influence CSC biomarker expression. The study showed that CD133/ALDH1 expression impacts HGSOC patients' survival and first suggests that CSCs might undergo phenotypic change during the disease course similarly to non stem-like cancer cells, providing also a first evidence that there is no correlation between CSCs and BRCA status. Copyright © 2017 Elsevier Ltd. All rights reserved.
Brant, Larry J; Ferrucci, Luigi; Sheng, Shan L; Concin, Hans; Zonderman, Alan B; Kelleher, Cecily C; Longo, Dan L; Ulmer, Hanno; Strasak, Alexander M
2010-12-01
Previous studies on blood pressure (BP) indices as a predictor of coronary heart disease (CHD) have provided equivocal results and generally relied on Cox proportional hazards regression methodology, with age and sex accounting for most of the predictive capability of the model. The aim of the present study was to use serially collected BP measurements to examine age-and gender-related differences in BP indices for predicting CHD. The predictive accuracy of time-dependent BP indices for CHD was investigated using a method of risk prediction based on posterior probabilities calculated from mixed-effects regression to utilize intraindividual differences in serial BP measurements according to age changes within gender groups. Data were collected prospectively from 2 community-dwelling cohort studies in the United States (Baltimore Longitudinal Study of Aging [BLSA]) and Europe (Vorarlberg Health Monitoring and Promotion Program [VHM&PP]). The study comprised 152,633 participants (aged 30-74 years) and 610,061 BP measurements. During mean follow-up of 7.5 years, 2457 nonfatal and fatal CHD events were observed. In both study populations, pulse pressure (PP) and systolic blood pressure (SBP) performed best as individual predictors of CHD in women (area under the receiver operating characteristic curve [AUC(ROC)] was between 0.83 and 0.85 for PP, and between 0.77 and 0.81 for SBP). Mean arterial pressure (MAP) and diastolic blood pressure (DBP) performed better for men (AUC(ROC) = 0.67 and 0.65 for MAP and DBP, respectively, in the BLSA; AUC(ROC) = 0.77 and 0.75 in the VHM&PP) than for women (AUC(ROC) = 0.60 for both MAP and DBP in the BLSA; AUC(ROC) = 0.75 and 0.52, respectively, in the VHM&PP). The degree of discrimination in both populations was overall greater but more varied for all BP indices for women (AUC(ROC) estimates between 0.85 [PP in the VHM&PP] and 0.52 [DBP in the VHM&PP]) than for men (AUC(ROC) estimates between 0.78 [MAP + PP in the VHM&PP] and 0.63 [PP in the BLSA]). Our findings indicate differences in discrimination between women and men in the accuracy of longitudinally collected BP measurements for predicting CHD, implicating the usefulness of gender-specific BP indices to assess individual CHD risk. Copyright © 2010. Published by EM Inc USA.
More About Robustness of Coherence
NASA Astrophysics Data System (ADS)
Li, Pi-Yu; Liu, Feng; Xu, Yan-Qin; La, Dong-Sheng
2018-07-01
Quantum coherence is an important physical resource in quantum computation and quantum information processing. In this paper, the distribution of the robustness of coherence in multipartite quantum system is considered. It is shown that the additivity of the robustness of coherence is not always valid for general quantum state, but the robustness of coherence is decreasing under partial trace for any bipartite quantum system. The ordering states with the coherence measures RoC, the l 1 norm of coherence C_{l1} and the relative entropy of coherence C r are also discussed.
ERIC Educational Resources Information Center
Starns, Jeffrey J.; Ratcliff, Roger; McKoon, Gail
2012-01-01
We tested two explanations for why the slope of the z-transformed receiver operating characteristic (zROC) is less than 1 in recognition memory: the unequal-variance account (target evidence is more variable than lure evidence) and the dual-process account (responding reflects both a continuous familiarity process and a threshold recollection…
ERIC Educational Resources Information Center
Shandley, Kerrie; Austin, David; Klein, Britt; Kyrios, Michael
2010-01-01
The objective of this study was to conduct an evaluation of Reach Out Central (ROC), an online gaming program designed to support the mental health of people aged 16-25. The evaluation sought to determine the benefit of playing ROC on alcohol use, use of coping strategies, psychological distress, resilience and satisfaction with life. Changes in…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-11
... the RoC. The process is available on the NTP Web site ( http://ntp.niehs.nih.gov/go/rocprocess ) or by... Counselors public meeting (76 FR 68461) on December 15, 2011 ( http://ntp.niehs.nih.gov/go/9741 ). The NTP... Web site ( http://ntp.niehs.nih.gov/go/rocprocess ) or by contacting Dr. Lunn (see ADDRESSES...
NASA Technical Reports Server (NTRS)
2000-01-01
When StenniSphere at John C. Stennis Space Center in Hancock County, Miss., opened in May 2000, it introduced the RocKeTeria, a new 1960s-style, space-themed restaurant located in the newly expanded visitor center. The restaurant, operated by the owners of Mary's Drive Inn of Biloxi, features an extensive collection of space-related photos from that era, as well as a full menu of home-style cooking.
ERIC Educational Resources Information Center
Starns, Jeffrey J.; Rotello, Caren M.; Hautus, Michael J.
2014-01-01
We tested the dual process and unequal variance signal detection models by jointly modeling recognition and source confidence ratings. The 2 approaches make unique predictions for the slope of the recognition memory zROC function for items with correct versus incorrect source decisions. The standard bivariate Gaussian version of the unequal…
Stephens, Shannon W.; Williams, Carolyn; Gray, Randal; Kerby, Jeffrey D.; Wang, Henry E.; Bosarge, Patrick L.
2016-01-01
Background The U.S. Food and Drug Administration and Department of Health and Human Services outline regulations allowing an Exception From Informed Consent (EFIC) for research conducted in an emergency settings. Acute care clinical trials utilizing EFIC must include community consultation and public disclosure (CC/PD) activities. We describe our experience using social media to facilitate the CC/PD process in two trauma resuscitation clinical trials. Methods We conducted local CC/PD activities for two multicenter trauma clinical trials, Pragmatic, Randomized Optimal Platelet and Plasma Ratios (PROPPR) and Prehospital Tranexamic Acid Use for Traumatic Brain Injury (ROC TXA). As part of the CC/PD process, we developed research study advertisements using the social media website Facebook. The Facebook advertisements directed users to a regional study website that contained trial information. We targeted the advertisements to specific demographic users, in specific geographic areas. We analyzed the data using descriptive statistics. Results During the study periods, the PROPPR Facebook advertisement was displayed 5,001,520 times, (12 displays per target population) with 374 individuals selected the advertisement. The ROC-TXA Facebook advertisement was displayed 3,806,448 times (8 per target population) with 790 individuals selecting the advertisement. Respondents to both Facebook advertisements were mostly male (52.6%), with the highest proportion between the ages 15-24 (28.2%). Collectively, 26.9% of individuals that clicked on the Facebook advertisement, spent > 3 minutes on the study website [3min – 49 min]. Commonly accessed webpages were “Contact Us” (PROPPR 5.5%, TXA 7.7%), “Study-specific FAQs” (PROPPR 2.4%), ROC-TXA 6.7%) and “Opt-Out of Research” (PROPPR 2.5%, ROC-TXA 3.8%). Of 51 total individuals viewing the opt-out of research information (PROPPR 19, ROC-TXA 32), Time spent on that specific page was modest (PROPPR 62 seconds, ROC-TXA 55 seconds), with no individuals requesting to opt-out of either study participation. Conclusion In clinical trauma trials, using EFIC, social media may provide a viable option for facilitating the CC/PD process. Level Of Evidence Descriptive Study, Level IV. PMID:26998781
Balasch, J; Vidal, E; Peñarrubia, J; Casamitjana, R; Carmona, F; Creus, M; Fábregues, F; Vanrell, J A
2001-08-01
It has been recently suggested that gonadotrophin-releasing hormone agonist down-regulation in some normogonadotrophic women may result in profound suppression of LH concentrations, impairing adequate oestradiol synthesis and IVF and pregnancy outcome. The aims of this study, where receiver-operating characteristic (ROC) analysis was used, were: (i) to assess the usefulness of serum LH measurement on stimulation day 7 (S7) as a predictor of ovarian response, IVF outcome, implantation, and the outcome of pregnancy in patients treated with recombinant FSH under pituitary suppression; and (ii) to define the best threshold value, if any, to discriminate between women with 'low' or 'normal' LH concentrations. A total of 144 infertile women undergoing IVF/intracytoplasmic sperm injection (ICSI) treatment were included. Seventy-two consecutive patients having a positive pregnancy test (including 58 ongoing pregnancies and 14 early pregnancy losses) were initially selected. As a control non-pregnant group, the next non-conception IVF/ICSI cycle after each conceptual cycle in our assisted reproduction programme was used. The median and range of LH values in non-conception cycles, conception cycles, ongoing pregnancies, and early pregnancy losses, clearly overlapped. ROC analysis showed that serum LH concentration on S7 was unable to discriminate between conception and non-conception cycles (AUC(ROC) = 0.52; 95% CI: 0.44 to 0.61) or ongoing pregnancy versus early pregnancy loss groups (AUC(ROC) = 0.59; 95% CI: 0.46 to 0.70). To assess further the potential impact of suppressed concentrations of circulating LH during ovarian stimulation on the outcome of IVF/ICSI treatment, the three threshold values of mid-follicular serum LH proposed in the literature (<1, < or =0.7, <0.5 IU/l) to discriminate between women with 'low' or 'normal' LH were applied to our study population. No significant differences were found with respect to ovarian response, IVF/ICSI outcome, implantation, and the outcome of pregnancy between 'low' and 'normal' S7 LH women as defined by those threshold values. Our results do not support the need for additional exogenous LH supplementation in down-regulated women receiving a recombinant FSH-only preparation.
Chu, Kuo-Chung; Huang, Yu-Shu; Tseng, Chien-Fu; Huang, Hsin-Jou; Wang, Chih-Huan; Tai, Hsin-Yi
2017-03-01
The purpose of this study is to examine the reliability of the clinical use of the self-built decision support system, diagnosis-supported attention deficit hyperactivity disorder (DS-ADHD), in an effort to develop the DS-ADHD system, by probing into the development of indicating patterns of past screening support systems for ADHD. The study collected data based on 107 subjects, who were divided into two groups, non-ADHD and ADHD, based on the doctor's determination, using the DSM-IV diagnostic standards. The two groups then underwent Test of Variables of Attention (TOVA) and DS-ADHD testing. The survey and testing results underwent one-way ANOVA and split-half method statistical analysis, in order to further understand whether there were any differences between the DS-ADHD and the identification tools used in today's clinical trials. The results of the study are as follows: 1) The ROC area between the TOVA and the clinical identification rate is 0.787 (95% confidence interval: 0.701-0.872); 2) The ROC area between the DS-ADHD and the clinical identification rate is 0.867 (95% confidence interval: 0.801-0.933). The study results show that DS-ADHD has the characteristics of screening for ADHD, based on its reliability and validity. It does not display any statistical differences when compared with TOVA systems that are currently on the market. However, the system is more effective and the accuracy rate is better than TOVA. It is a good tool to screen ADHD not only in Chinese children, but also in western country. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Alvarez-Twose, I; González-de-Olano, D; Sánchez-Muñoz, L; Matito, A; Jara-Acevedo, M; Teodosio, C; García-Montero, A; Morgado, J M; Orfao, A; Escribano, L
2012-01-01
A variable percentage of patients with systemic mast cell (MC) activation symptoms meet criteria for systemic mastocytosis (SM). We prospectively evaluated the clinical utility of the REMA score versus serum baseline tryptase (sBt) levels for predicting MC clonality and SM in 158 patients with systemic MC activation symptoms in the absence of mastocytosis in the skin (MIS). World Health Organization criteria for SM were applied in all cases. MC clonality was defined as the presence of KIT-mutated MC or by a clonal HUMARA test. The REMA score consisted of the assignment of positive or negative points as follows: male (+1), female (-1), sBt <15 μg/l (-1) or >25 μg/l (+2), presence (-2) or absence (+1) of pruritus, hives or angioedema and presence (+3) of presyncope or syncope. Efficiency of the REMA score for predicting MC clonality and SM was assessed by receiver operating characteristic (ROC) curve analyses and compared to those obtained by means of sBt levels alone. Molecular studies revealed the presence of clonal MC in 68/80 SM cases and in 11/78 patients who did not meet the criteria for SM. ROC curve analyses confirmed the greater sensitivity and a similar specificity of the REMA score versus sBt levels (84 vs. 59% and 74 vs. 70% for MC clonality and 87 vs. 62% and 73 vs. 71% for SM, respectively). Our results confirm the clinical utility of the REMA score to predict MC clonality and SM in patients suffering from systemic MC activation symptoms without MIS. Copyright © 2011 S. Karger AG, Basel.
The Reliability of a Standardized Reporting System for the Diagnosis of Appendicitis.
Simianu, Vlad V; Shamitoff, Anna; Hippe, Daniel S; Godwin, Benjamin D; Shriki, Jabi E; Drake, Frederick T; O'Malley, Ryan B; Maximin, Suresh; Bastawrous, Sarah; Moshiri, Mariam; Lee, Jean H; Cuevas, Carlos; Dighe, Manjiri; Flum, David; Bhargava, Puneet
Computed tomography (CT) is a fast and ubiquitous tool to evaluate intra-abdominal organs and diagnose appendicitis. However, traditional CT reporting does not necessarily capture the degree of uncertainty and indeterminate findings are still common. The purpose of this study was to evaluate the reproducibility of a standardized CT reporting system for appendicitis across a large population and the system's impact on radiologists' certainty in diagnosing appendicitis. Using a previously described standardized reporting system, eight radiologists retrospectively evaluated CT scans, blinded to all clinical information, in a stratified random sample of 237 patients from a larger cohort of patients imaged for possible appendicitis (2010-2014). Receiver operating characteristic (ROC) curves and the area under the ROC curve (AUC) were used to evaluate the diagnostic performance of readers for identifying appendicitis. Two-thirds of these scans were randomly selected to be independently read by a second reader, using the original CT reports to balance the number of positive, negative and indeterminate exams across all readers. Inter-reader agreement was evaluated. There were 113 patients with appendicitis (mean age 38, 67% male). Using the standardized report, radiologists were highly accurate at identifying appendicitis (AUC=0.968, 95%CI confidence interval: 0.95, 0.99. Inter-reader agreement was >80% for most objective findings, and certainty in diagnosing appendicitis was high and reproducible (AUC=0.955 and AUC=0.936 for the first and second readers, respectively). Using a standardized reporting system resulted in high reproducibility of objective CT findings for appendicitis and achieved high diagnostic accuracy in an at-risk population. Predictive tools based on this reporting system may further improve communication about certainty in diagnosis and guide patient management, especially when CT findings are indeterminate. Copyright © 2017 Elsevier Inc. All rights reserved.
Wunderlich, Adam; Abbey, Craig K
2013-11-01
Studies of lesion detectability are often carried out to evaluate medical imaging technology. For such studies, several approaches have been proposed to measure observer performance, such as the receiver operating characteristic (ROC), the localization ROC (LROC), the free-response ROC (FROC), the alternative free-response ROC (AFROC), and the exponentially transformed FROC (EFROC) paradigms. Therefore, an experimenter seeking to carry out such a study is confronted with an array of choices. Traditionally, arguments for different approaches have been made on the basis of practical considerations (statistical power, etc.) or the gross level of analysis (case-level or lesion-level). This article contends that a careful consideration of utility should form the rationale for matching the assessment paradigm to the clinical task of interest. In utility theory, task performance is commonly evaluated with total expected utility, which integrates the various event utilities against the probability of each event. To formalize the relationship between expected utility and the summary curve associated with each assessment paradigm, the concept of a "natural" utility structure is proposed. A natural utility structure is defined for a summary curve when the variables associated with the summary curve axes are sufficient for computing total expected utility, assuming that the disease prevalence is known. Natural utility structures for ROC, LROC, FROC, AFROC, and EFROC curves are introduced, clarifying how the utilities of correct and incorrect decisions are aggregated by summary curves. Further, conditions are given under which general utility structures for localization-based methodologies reduce to case-based assessment. Overall, the findings reveal how summary curves correspond to natural utility structures of diagnostic tasks, suggesting utility as a motivating principle for choosing an assessment paradigm.
Schut, Henk; Stroebe, Margaret S.; Wilson, Stewart; Birrell, John
2016-01-01
Objective This study assessed the validity of the Indicator of Bereavement Adaptation Cruse Scotland (IBACS). Designed for use in clinical and non-clinical settings, the IBACS measures severity of grief symptoms and risk of developing complications. Method N = 196 (44 male, 152 female) help-seeking, bereaved Scottish adults participated at two timepoints: T1 (baseline) and T2 (after 18 months). Four validated assessment instruments were administered: CORE-R, ICG-R, IES-R, SCL-90-R. Discriminative ability was assessed using ROC curve analysis. Concurrent validity was tested through correlation analysis at T1. Predictive validity was assessed using correlation analyses and ROC curve analysis. Optimal IBACS cutoff values were obtained by calculating a maximal Youden index J in ROC curve analysis. Clinical implications were compared across instruments. Results ROC curve analysis results (AUC = .84, p < .01, 95% CI between .77 and .90) indicated the IBACS is a good diagnostic instrument for assessing complicated grief. Positive correlations (p < .01, 2-tailed) with all four instruments at T1 demonstrated the IBACS' concurrent validity, strongest with complicated grief measures (r = .82). Predictive validity was shown to be fair in T2 ROC curve analysis results (n = 67, AUC = .78, 95% CI between .65 and .92; p < .01). Predictive validity was also supported by stable positive correlations between IBACS and other instruments at T2. Clinical indications were found not to differ across instruments. Conclusions The IBACS offers effective grief symptom and risk assessment for use by non-clinicians. Indications are sufficient to support intake assessment for a stepped model of bereavement intervention. PMID:27741246
Freitas, F G R; Bafi, A T; Nascente, A P M; Assunção, M; Mazza, B; Azevedo, L C P; Machado, F R
2013-03-01
The applicability of pulse pressure variation (ΔPP) to predict fluid responsiveness using lung-protective ventilation strategies is uncertain in clinical practice. We designed this study to evaluate the accuracy of this parameter in predicting the fluid responsiveness of septic patients ventilated with low tidal volumes (TV) (6 ml kg(-1)). Forty patients after the resuscitation phase of severe sepsis and septic shock who were mechanically ventilated with 6 ml kg(-1) were included. The ΔPP was obtained automatically at baseline and after a standardized fluid challenge (7 ml kg(-1)). Patients whose cardiac output increased by more than 15% were considered fluid responders. The predictive values of ΔPP and static variables [right atrial pressure (RAP) and pulmonary artery occlusion pressure (PAOP)] were evaluated through a receiver operating characteristic (ROC) curve analysis. Thirty-four patients had characteristics consistent with acute lung injury or acute respiratory distress syndrome and were ventilated with high levels of PEEP [median (inter-quartile range) 10.0 (10.0-13.5)]. Nineteen patients were considered fluid responders. The RAP and PAOP significantly increased, and ΔPP significantly decreased after volume expansion. The ΔPP performance [ROC curve area: 0.91 (0.82-1.0)] was better than that of the RAP [ROC curve area: 0.73 (0.59-0.90)] and pulmonary artery occlusion pressure [ROC curve area: 0.58 (0.40-0.76)]. The ROC curve analysis revealed that the best cut-off for ΔPP was 6.5%, with a sensitivity of 0.89, specificity of 0.90, positive predictive value of 0.89, and negative predictive value of 0.90. Automatized ΔPP accurately predicted fluid responsiveness in septic patients ventilated with low TV.
Fluorescence spectroscopy for diagnosis of squamous intraepithelial lesions of the cervix.
Mitchell, M F; Cantor, S B; Ramanujam, N; Tortolero-Luna, G; Richards-Kortum, R
1999-03-01
To calculate receiver operating characteristic (ROC) curves for fluorescence spectroscopy in order to measure its performance in the diagnosis of squamous intraepithelial lesions (SILs) and to compare these curves with those for other diagnostic methods: colposcopy, cervicography, speculoscopy, Papanicolaou smear screening, and human papillomavirus (HPV) testing. Data from our previous clinical study were used to calculate ROC curves for fluorescence spectroscopy. Curves for other techniques were calculated from other investigators' reports. To identify these, a MEDLINE search for articles published from 1966 to 1996 was carried out, using the search terms "colposcopy," "cervicoscopy," "cervicography," "speculoscopy," "Papanicolaou smear," "HPV testing," "fluorescence spectroscopy," and "polar probe" in conjunction with the terms "diagnosis," "positive predictive value," "negative predictive value," and "receiver operating characteristic curve." We found 270 articles, from which articles were selected if they reported results of studies involving high-disease-prevalence populations, reported findings of studies in which colposcopically directed biopsy was the criterion standard, and included sufficient data for recalculation of the reported sensitivities and specificities. We calculated ROC curves for fluorescence spectroscopy using Bayesian and neural net algorithms. A meta-analytic approach was used to calculate ROC curves for the other techniques. Areas under the curves were calculated. Fluorescence spectroscopy using the neural net algorithm had the highest area under the ROC curve, followed by fluorescence spectroscopy using the Bayesian algorithm, followed by colposcopy, the standard diagnostic technique. Cervicography, Papanicolaou smear screening, and HPV testing performed comparably with each other but not as well as fluorescence spectroscopy and colposcopy. Fluorescence spectroscopy performs better than colposcopy and other techniques in the diagnosis of SILs. Because it also permits real-time diagnosis and has the potential of being used by inexperienced health care personnel, this technology holds bright promise.
Hasegawa, Kunihiro; Takata, Ryo; Nishikawa, Hiroki; Enomoto, Hirayuki; Ishii, Akio; Iwata, Yoshinori; Miyamoto, Yuho; Ishii, Noriko; Yuri, Yukihisa; Nakano, Chikage; Nishimura, Takashi; Yoh, Kazunori; Aizawa, Nobuhiro; Sakai, Yoshiyuki; Ikeda, Naoto; Takashima, Tomoyuki; Iijima, Hiroko; Nishiguchi, Shuhei
2016-09-12
We aimed to examine the effect of Wisteria floribunda agglutinin-positive Mac-2-binding protein (WFA⁺-M2BP) level on survival comparing with other laboratory liver fibrosis markers in hepatitis C virus (HCV)-related compensated liver cirrhosis (LC) (n = 165). For assessing prognostic performance of continuous fibrosis markers, we adapted time-dependent receiver operating characteristics (ROC) curves for clinical outcome. In time-dependent ROC analysis, annual area under the ROCs (AUROCs) were plotted. We also calculated the total sum of AUROCs in all time-points (TAAT score) in each fibrosis marker. WFA⁺-M2BP value ranged from 0.66 cutoff index (COI) to 19.95 COI (median value, 5.29 COI). Using ROC analysis for survival, the optimal cutoff point for WFA⁺-M2BP was 6.15 COI (AUROC = 0.79348, sensitivity = 80.0%, specificity = 74.78%). The cumulative five-year survival rate in patients with WFA⁺-M2BP ≥ 6.15 COI (n = 69) was 43.99%, while that in patients with WFA⁺-M2BP < 6.15 COI (n = 96) was 88.40% (p < 0.0001). In the multivariate analysis, absence of hepatocellular carcinoma (p = 0.0008), WFA⁺-M2BP < 6.15 COI (p = 0.0132), achievement of sustained virological response (p < 0.0001) and des-γ-carboxy prothrombin < 41 mAU/mL (p = 0.0018) were significant favorable predictors linked to survival. In time-dependent ROC analysis in all cases, WFA⁺-M2BP had the highest TAAT score among liver fibrosis markers. In conclusion, WFA⁺-M2BP can be a useful predictor in HCV-related compensated LC.
Gomes, Ana Luísa; Ramos, João Carlos; Santos-del Riego, Sérgio; Montero, Javier; Albaladejo, Alberto
2015-02-01
The purpose of this study is to evaluate the thermocycling effect on the microshear bond strength (μSBS) of different self-adhesive resin cements to zirconia using tribochemical silica coating Rocatec™ (ROC) and Er:YAG as surface conditioners. Two hundred forty square-like zirconia samples were polished and randomly assigned in four groups according surface treatment applied as follows: (1) no treatment (NT), (2) silica coating with ROC, 3) Er:YAG laser irradiation (LAS: 2.940 nm, 200 mJ; 10 Hz), and (4) laser followed by Rocatec™ (LAROC). Each group was divided into two subgroups according the resin tested as follows: (A) BiFix SE (BIF) and (B) Clearfil SA (CLE). After 24 h, half of the specimens from each subgroup were tested. The other half was stored and thermocycled (5-55 °C/5,000 cycles). A μSBS test was performed using a universal testing machine (cross head speed = 0.5 mm/min). Failure modes were recorded and observed by scanning electronic microscopy. Data was analyzed with ANOVA, Student's t test, and chi-square tests, and linear regression was performed (p < 0.05). Before thermocycling, both cements showed higher μSBS results with ROC and LAROC. After aging, (1) all BIF specimens evidenced severely decreased adhesion with mostly adhesive failures and (2) CLE maintained the initial results in ROC and LAROC groups, performing better with ROC. Thermocycling did not negatively influence the resin-zirconia μSBS results in the self-adhesive resin cement containing 10-MDP when used on zirconia surface coated with silica, independently of previous Er:YAG surface treatment.
NASA Astrophysics Data System (ADS)
He, Xin; Frey, Eric C.
2007-03-01
Binary ROC analysis has solid decision-theoretic foundations and a close relationship to linear discriminant analysis (LDA). In particular, for the case of Gaussian equal covariance input data, the area under the ROC curve (AUC) value has a direct relationship to the Hotelling trace. Many attempts have been made to extend binary classification methods to multi-class. For example, Fukunaga extended binary LDA to obtain multi-class LDA, which uses the multi-class Hotelling trace as a figure-of-merit, and we have previously developed a three-class ROC analysis method. This work explores the relationship between conventional multi-class LDA and three-class ROC analysis. First, we developed a linear observer, the three-class Hotelling observer (3-HO). For Gaussian equal covariance data, the 3- HO provides equivalent performance to the three-class ideal observer and, under less strict conditions, maximizes the signal to noise ratio for classification of all pairs of the three classes simultaneously. The 3-HO templates are not the eigenvectors obtained from multi-class LDA. Second, we show that the three-class Hotelling trace, which is the figureof- merit in the conventional three-class extension of LDA, has significant limitations. Third, we demonstrate that, under certain conditions, there is a linear relationship between the eigenvectors obtained from multi-class LDA and 3-HO templates. We conclude that the 3-HO based on decision theory has advantages both in its decision theoretic background and in the usefulness of its figure-of-merit. Additionally, there exists the possibility of interpreting the two linear features extracted by the conventional extension of LDA from a decision theoretic point of view.
Xia, Jiaohui; Zhang, Hui; Ding, Shaoxuan; Li, Changyu; Ding, Jincheng; Lu, Jie
2017-07-12
The primary pollutants in reverse-osmosis concentrates (ROC) are the substances with the UV absorbance at 254 nm (UV 254 ), which is closely related to humic substances that can be degraded by humus-reducing bacteria. This work studied the degradation characteristics of humus-reducing bacteria in ROC treatment. The physiological and biochemical characteristics of humus-reducing bacteria were investigated, and the effects of pH values and electron donors on the reduction of humic analog, antraquinone-2, 6-disulfonate were explored to optimize the degradation. Furthermore, the O 3 -assisted UV-Fenton method was applied for the pretreatment of ROC, and the degradation of UV 254 absorbance was apparently promoted with their removal rate, reaching 84.2% after 10 days of degradation by humus-reducing bacteria.
Short Personality and Life Event scale for detection of suicide attempters.
Artieda-Urrutia, Paula; Delgado-Gómez, David; Ruiz-Hernández, Diego; García-Vega, Juan Manuel; Berenguer, Nuria; Oquendo, Maria A; Blasco-Fontecilla, Hilario
2015-01-01
To develop a brief and reliable psychometric scale to identify individuals at risk for suicidal behaviour. Case-control study. 182 individuals (61 suicide attempters, 57 psychiatric controls, and 64 psychiatrically healthy controls) aged 18 or older, admitted to the Emergency Department at Puerta de Hierro University Hospital in Madrid, Spain. All participants completed a form including their socio-demographic and clinical characteristics, and the Personality and Life Events scale (27 items). To assess Axis I diagnoses, all psychiatric patients (including suicide attempters) were administered the Mini International Neuropsychiatric Interview. Descriptive statistics were computed for the socio-demographic factors. Additionally, χ(2) independence tests were applied to evaluate differences in socio-demographic and clinical variables, and the Personality and Life Events scale between groups. A stepwise linear regression with backward variable selection was conducted to build the Short Personality Life Event (S-PLE) scale. In order to evaluate the accuracy, a ROC analysis was conducted. The internal reliability was assessed using Cronbach's α, and the external reliability was evaluated using a test-retest procedure. The S-PLE scale, composed of just 6 items, showed good performance in discriminating between medical controls, psychiatric controls and suicide attempters in an independent sample. For instance, the S-PLE scale discriminated between past suicide and past non-suicide attempters with sensitivity of 80% and specificity of 75%. The area under the ROC curve was 88%. A factor analysis extracted only one factor, revealing a single dimension of the S-PLE scale. Furthermore, the S-PLE scale provides values of internal and external reliability between poor (test-retest: 0.55) and acceptable (Cronbach's α: 0.65) ranges. Administration time is about one minute. The S-PLE scale is a useful and accurate instrument for estimating the risk of suicidal behaviour in settings where the time is scarce. Copyright © 2015 SEP y SEPB. Published by Elsevier España. All rights reserved.
Mandal, Santosh Kumar; Sandhya, Pulukool; Kabeerdoss, Jayakanthan; Ramya, Janardana; Mahasampath, Gowri; Danda, Debashish
2018-05-01
Human and animal model studies suggest CXCL13 is a potential biomarker in primary Sjögren's syndrome (pSS). CXCL13 has not been studied in Indian patients with pSS. pSS cases classified by American European Consensus Group (AECG) or American college of Rheumatology(ACR) 2012 criteria, attending rheumatology clinic between July 2014 and July 2015 were included. Hospital staff and healthy, non-blood related family members of patients constituted the control group. pSS cases underwent clinical evaluation, laboratory investigations, ESSDAI and ESSPRI scoring. Unstimulated saliva was collected by the spitting method. Salivary and serum CXCL13 were quantified by indirect ELISA. CXCL13 positivity was determined using Receiver Operator Characteristic (ROC) curve. STATA13.1 (StataCorpLP,Texas,USA) software was used for statistical analysis. In this study, 45 pSS cases and 42 healthy controls were recruited. In pSS, median levels of serum CXCL13, but not salivary CXCL13 was significantly higher as compared to the corresponding levels in healthy controls (p < 0.001). Using cutoff of 43.03 pg/ml obtained by ROC, serum CXCL13 positivity was seen in 31/43(72.1%) cases and 10/34 (29.4%) controls, respectively. Serum CXCL13 levels among pSS patients on treatment, treatment naïve patients and healthy controls were statistically different. Serum CXCL13 positivity was associated with oral symptoms (p = 0.02), ocular signs (p = 0.03) and hyperglobulinemia (p = 0.01). There was no association of salivary CXCL13 level with any of the clinical variables. While serum CXCL13 was elevated in pSS, salivary CXCL13 was not. In conclusion, serum CXCL13 positivity was found to be associated with oral symptoms, ocular signs and hyperglobulinemia in pSS.
Gai, Chiara; Camussi, Francesco; Broccoletti, Roberto; Gambino, Alessio; Cabras, Marco; Molinaro, Luca; Carossa, Stefano; Camussi, Giovanni; Arduino, Paolo G
2018-04-18
Several studies in the past have investigated the expression of micro RNAs (miRNAs) in saliva as potential biomarkers. Since miRNAs associated with extracellular vesicles (EVs) are known to be protected from enzymatic degradation, we evaluated whether salivary EVs from patients with oral squamous cell carcinoma (OSCC) were enriched with specific subsets of miRNAs. OSCC patients and controls were matched with regards to age, gender and risk factors. Total RNA was extracted from salivary EVs and the differential expression of miRNAs was evaluated by qRT-PCR array and qRT-PCR. The discrimination power of up-regulated miRNAs as biomarkers in OSCC patients versus controls was evaluated by the Receiver Operating Characteristic (ROC) curves. A preliminary qRT-PCR array was performed on samples from 5 OSCC patients and 5 healthy controls whereby a subset of miRNAs were identified that were differentially expressed. On the basis of these results, a cohort of additional 16 patients and 6 controls were analyzed to further confirm the miRNAs that were up-regulated or selectively expressed in the previous pilot study. The following miRNAs: miR-302b-3p and miR-517b-3p were expressed only in EVs from OSCC patients and miR-512-3p and miR-412-3p were up-regulated in salivary EVs from OSCC patients compared to controls with the ROC curve showing a good discrimination power for OSCC diagnosis. The Kyoto Encyclopedia of Gene and Genomes (KEGG) pathway analysis suggested the possible involvement of the miRNAs identified in pathways activated in OSCC. In this work, we suggest that salivary EVs isolated by a simple charge-based precipitation technique can be exploited as a non-invasive source of miRNAs for OSCC diagnosis. Moreover, we have identified a subset of miRNAs selectively enriched in EVs of OSCC patients that could be potential biomarkers.
Aortic elongation and the risk for dissection: the Tübingen Aortic Pathoanatomy (TAIPAN) project†.
Krüger, Tobias; Oikonomou, Alexandre; Schibilsky, David; Lescan, Mario; Bregel, Katharina; Vöhringer, Luise; Schneider, Wilke; Lausberg, Henning; Blumenstock, Gunnar; Bamberg, Fabian; Schlensak, Christian
2017-06-01
We measured aortic dimensions, particularly length parameters, using 3D imaging with the aim of refining the risk-morphology for Stanford type A aortic dissection (TAD). Computer tomography angiography studies were analysed using the curved multiplanar reformats. At defined landmarks, the diameters and lengths of aortic segments were recorded. Three groups were compared retrospectively: patients actually suffering from a TAD (TAD-group; n = 150), patients before suffering a TAD (preTAD-group n = 15) and a healthy control group ( n = 215). Receiver operating characteristic curves (ROCs) were analysed (control versus preTAD) to study the diagnostic value of the individual variables. Median diameters of preTAD (43 mm) and TAD (50 mm) aortas were significantly ( P < 0.001) larger than those of the control group (35 mm). Ninety-three percent of preTAD and 68% of TAD aortas were less than 55 mm in the mid-ascending aorta. The ascending aorta and the aortic arch were significantly longer in both preTAD and TAD aortas compared to control aortas ( P < 0.001); in the control aortas the central line distance from the aortic valve to the brachiocephalic trunk was 93 mm. In preTAD aortas, it was 111 mm, and it was 117 mm in TAD aortas ( P < 0.001). In ROC analysis, the area under the curve was 0.912 for the ascending diameter and 0.787 for the ascending and arch lengths. TAD-prediction based on the aortic diameter is ineffective. Besides circumferential dilatation, ascending aorta elongation precedes TAD and appears to be a useful additional parameter for prognostication. We propose a diagnostic score involving ascending aorta diameter and length. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Exploring Polypharmacology Using a ROCS-Based Target Fishing Approach
2012-01-01
target representatives. Target profiles were then generated for a given query molecule by computing maximal shape/ chemistry overlap between the query...molecule and the drug sets assigned to each protein target. The overlap was computed using the program ROCS (Rapid Overlay of Chemical Structures ). We...approaches in off-target prediction has been reviewed.9,10 Many structure -based target fishing (SBTF) approaches, such as INVDOCK11 and Target Fishing Dock
Target Detection and Identification Using Canonical Correlations Analysis and Subspace Partitioning
2008-04-01
Fig. 2. ROCs for DCC, DCC-P, NNLS, and NNLSP (Present chemical=t1, background= t56 , SNR= 5 dB) alarm, or 1−specificity, and PD is the probability of...discrimination values are given in each ROC plot. In Fig. 2, we use t56 as the background, and t1 as the target chemical. The SNR is 5 dB. For each
ERIC Educational Resources Information Center
Bowers, Alex J.; Sprott, Ryan; Taff, Sherry A.
2013-01-01
The purpose of this study is to review the literature on the most accurate indicators of students at risk of dropping out of high school. We used Relative Operating Characteristic (ROC) analysis to compare the sensitivity and specificity of 110 dropout flags across 36 studies. Our results indicate that 1) ROC analysis provides a means to compare…
Enhancement of the Daytime MODIS Based Aircraft Icing Potential Algorithm Using Mesoscale Model Data
2006-03-01
January, 15, 2006 ...... 37 x Figure 25. ROC curves using 3 hour PIREPs and Alexander Tmap with symbols plotted at the 0.5 threshold values...42 Figure 26. ROC curves using 3 hour PIREPs and Alexander Tmap with symbols plotted at the 0.5 threshold values...Table 4. Results using T icing potential values from the Alexander Tmap , and 3 Hour PIREPs
ERIC Educational Resources Information Center
Starns, Jeffrey J.; Rotello, Caren M.; Ratcliff, Roger
2012-01-01
Koen and Yonelinas (2010; K&Y) reported that mixing classes of targets that had short (weak) or long (strong) study times had no impact on zROC slope, contradicting the predictions of the encoding variability hypothesis. We show that they actually derived their predictions from a mixture unequal-variance signal detection (UVSD) model, which…
De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte
2017-01-01
We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Zhang, Ying; Alonzo, Todd A
2016-11-01
In diagnostic medicine, the volume under the receiver operating characteristic (ROC) surface (VUS) is a commonly used index to quantify the ability of a continuous diagnostic test to discriminate between three disease states. In practice, verification of the true disease status may be performed only for a subset of subjects under study since the verification procedure is invasive, risky, or expensive. The selection for disease examination might depend on the results of the diagnostic test and other clinical characteristics of the patients, which in turn can cause bias in estimates of the VUS. This bias is referred to as verification bias. Existing verification bias correction in three-way ROC analysis focuses on ordinal tests. We propose verification bias-correction methods to construct ROC surface and estimate the VUS for a continuous diagnostic test, based on inverse probability weighting. By applying U-statistics theory, we develop asymptotic properties for the estimator. A Jackknife estimator of variance is also derived. Extensive simulation studies are performed to evaluate the performance of the new estimators in terms of bias correction and variance. The proposed methods are used to assess the ability of a biomarker to accurately identify stages of Alzheimer's disease. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Kim, M. S.; Onda, Y.; Kim, J. K.
2015-01-01
SHALSTAB model applied to shallow landslides induced by rainfall to evaluate soil properties related with the effect of soil depth for a granite area in Jinbu region, Republic of Korea. Soil depth measured by a knocking pole test and two soil parameters from direct shear test (a and b) as well as one soil parameters from a triaxial compression test (c) were collected to determine the input parameters for the model. Experimental soil data were used for the first simulation (Case I) and, soil data represented the effect of measured soil depth and average soil depth from soil data of Case I were used in the second (Case II) and third simulations (Case III), respectively. All simulations were analysed using receiver operating characteristic (ROC) analysis to determine the accuracy of prediction. ROC analysis results for first simulation showed the low ROC values under 0.75 may be due to the internal friction angle and particularly the cohesion value. Soil parameters calculated from a stochastic hydro-geomorphological model were applied to the SHALSTAB model. The accuracy of Case II and Case III using ROC analysis showed higher accuracy values rather than first simulation. Our results clearly demonstrate that the accuracy of shallow landslide prediction can be improved when soil parameters represented the effect of soil thickness.
Irwin, R John; Irwin, Timothy C
2011-06-01
Making clinical decisions on the basis of diagnostic tests is an essential feature of medical practice and the choice of the decision threshold is therefore crucial. A test's optimal diagnostic threshold is the threshold that maximizes expected utility. It is given by the product of the prior odds of a disease and a measure of the importance of the diagnostic test's sensitivity relative to its specificity. Choosing this threshold is the same as choosing the point on the Receiver Operating Characteristic (ROC) curve whose slope equals this product. We contend that a test's likelihood ratio is the canonical decision variable and contrast diagnostic thresholds based on likelihood ratio with two popular rules of thumb for choosing a threshold. The two rules are appealing because they have clear graphical interpretations, but they yield optimal thresholds only in special cases. The optimal rule can be given similar appeal by presenting indifference curves, each of which shows a set of equally good combinations of sensitivity and specificity. The indifference curve is tangent to the ROC curve at the optimal threshold. Whereas ROC curves show what is feasible, indifference curves show what is desirable. Together they show what should be chosen. Copyright © 2010 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
2014-01-01
Spatial heterogeneity in the incidence of visceral leishmaniasis (VL) is an important aspect to be considered in planning control actions for the disease. The objective of this study was to predict areas at high risk for visceral leishmaniasis (VL) based on socioeconomic indicators and remote sensing data. We applied classification and regression trees to develop and validate prediction models. Performance of the models was assessed by means of sensitivity, specificity and area under the ROC curve. The model developed was able to discriminate 15 subsets of census tracts (CT) with different probabilities of containing CT with high risk of VL occurrence. The model presented, respectively, in the validation and learning samples, sensitivity of 79% and 52%, specificity of 75% and 66%, and area under the ROC curve of 83% and 66%. Considering the complex network of factors involved in the occurrence of VL in urban areas, the results of this study showed that the development of a predictive model for VL might be feasible and useful for guiding interventions against the disease, but it is still a challenge as demonstrated by the unsatisfactory predictive performance of the model developed. PMID:24885128
Bago, Alberto; Cano, Custodia; Toussaint, Jean-Patrick; Smith, Sally; Dickson, Sandy
2006-09-01
Monoxenic symbioses between the arbuscular mycorrhizal (AM) fungus Glomus intraradices and two nontransformed tomato root organ cultures (ROCs) were established. Wild-type tomato ROC from cultivar "RioGrande 76R" was employed as a control for mycorrhizal colonization and compared with its mutant line (rmc), which exhibits a highly reduced mycorrhizal colonization (rmc) phenotype. Structural features of the two root lines were similar when grown either in soil or under in vitro conditions, indicating that neither monoxenic culturing nor the rmc mutation affected root development or behavior. Colonization by G. intraradices in monoxenic culture of the wild-type line was low (<10%) but supported extensive development of extraradical mycelium, branched absorbing structures, and spores. The reduced colonization of rmc under monoxenic conditions (0.6%) was similar to that observed previously in soil. Extraradical development of runner hyphae was low and proportional to internal colonization. Few spores were produced. These results might suggest that carbon transfer may be modified in the rmc mutant. Our results support the usefulness of monoxenically obtained mycorrhizas for investigation of AM colonization and intraradical symbiotic functioning.
Machine learning study for the prediction of transdermal peptide
NASA Astrophysics Data System (ADS)
Jung, Eunkyoung; Choi, Seung-Hoon; Lee, Nam Kyung; Kang, Sang-Kee; Choi, Yun-Jaie; Shin, Jae-Min; Choi, Kihang; Jung, Dong Hyun
2011-04-01
In order to develop a computational method to rapidly evaluate transdermal peptides, we report approaches for predicting the transdermal activity of peptides on the basis of peptide sequence information using Artificial Neural Network (ANN), Partial Least Squares (PLS) and Support Vector Machine (SVM). We identified 269 transdermal peptides by the phage display technique and use them as the positive controls to develop and test machine learning models. Combinations of three descriptors with neural network architectures, the number of latent variables and the kernel functions are tried in training to make appropriate predictions. The capacity of models is evaluated by means of statistical indicators including sensitivity, specificity, and the area under the receiver operating characteristic curve (ROC score). In the ROC score-based comparison, three methods proved capable of providing a reasonable prediction of transdermal peptide. The best result is obtained by SVM model with a radial basis function and VHSE descriptors. The results indicate that it is possible to discriminate between transdermal peptides and random sequences using our models. We anticipate that our models will be applicable to prediction of transdermal peptide for large peptide database for facilitating efficient transdermal drug delivery through intact skin.
Recognition errors suggest fast familiarity and slow recollection in rhesus monkeys
Basile, Benjamin M.; Hampton, Robert R.
2013-01-01
One influential model of recognition posits two underlying memory processes: recollection, which is detailed but relatively slow, and familiarity, which is quick but lacks detail. Most of the evidence for this dual-process model in nonhumans has come from analyses of receiver operating characteristic (ROC) curves in rats, but whether ROC analyses can demonstrate dual processes has been repeatedly challenged. Here, we present independent converging evidence for the dual-process model from analyses of recognition errors made by rhesus monkeys. Recognition choices were made in three different ways depending on processing duration. Short-latency errors were disproportionately false alarms to familiar lures, suggesting control by familiarity. Medium-latency responses were less likely to be false alarms and were more accurate, suggesting onset of a recollective process that could correctly reject familiar lures. Long-latency responses were guesses. A response deadline increased false alarms, suggesting that limiting processing time weakened the contribution of recollection and strengthened the contribution of familiarity. Together, these findings suggest fast familiarity and slow recollection in monkeys, that monkeys use a “recollect to reject” strategy to countermand false familiarity, and that primate recognition performance is well-characterized by a dual-process model consisting of recollection and familiarity. PMID:23864646
Objective Assessment of Image Quality VI: Imaging in Radiation Therapy
Barrett, Harrison H.; Kupinski, Matthew A.; Müeller, Stefan; Halpern, Howard J.; Morris, John C.; Dwyer, Roisin
2015-01-01
Earlier work on Objective Assessment of Image Quality (OAIQ) focused largely on estimation or classification tasks in which the desired outcome of imaging is accurate diagnosis. This paper develops a general framework for assessing imaging quality on the basis of therapeutic outcomes rather than diagnostic performance. By analogy to Receiver Operating Characteristic (ROC) curves and their variants as used in diagnostic OAIQ, the method proposed here utilizes the Therapy Operating Characteristic or TOC curves, which are plots of the probability of tumor control vs. the probability of normal-tissue complications as the overall dose level of a radiotherapy treatment is varied. The proposed figure of merit is the area under the TOC curve, denoted AUTOC. This paper reviews an earlier exposition of the theory of TOC and AUTOC, which was specific to the assessment of image-segmentation algorithms, and extends it to other applications of imaging in external-beam radiation treatment as well as in treatment with internal radioactive sources. For each application, a methodology for computing the TOC is presented. A key difference between ROC and TOC is that the latter can be defined for a single patient rather than a population of patients. PMID:24200954
Kido, Jun-Ichi; Murakami, Shinya; Kitamura, Masahiro; Yanagita, Manabu; Tabeta, Koichi; Yamazaki, Kazuhisa; Yoshie, Hiromasa; Watanabe, Hisashi; Izumi, Yuichi; Suda, Reiko; Yamamoto, Matsuo; Shiba, Hideki; Fujita, Tsuyoshi; Kurihara, Hidemi; Mizuno, Mitsuharu; Mishima, Akihiro; Kawahara, Nobumasa; Hashimoto, Kazuhiro; Naruishi, Koji; Nagata, Toshihiko
2017-09-06
Calprotectin, an inflammation-related protein, is present in gingival crevicular fluid (GCF) and the determination of calprotectin is useful for diagnosing periodontal diseases. We have recently developed a novel immunochromatographic (IC) chip system (SI-101402) to determine calprotectin levels in GCF. In the present study, the usefulness of this diagnostic system was investigated in patients with periodontal diseases. Thirty-six patients with periodontal diseases participated in this clinical test at multiple centers. Periodontitis sites (n=118) and non-periodontitis (healthy) sites (n=120) were selected after periodontal examination. GCF collection and periodontal examination were performed at baseline, after supragingival and subgingival scaling and root planing. Calprotectin amount in GCF was determined using a novel IC chip system and evaluated as a visual score and an IC reader value. The correlation between GCF calprotectin levels, clinical indicators and changes in calprotectin levels by periodontal treatments were investigated. Receiver operating characteristic (ROC) analysis of IC reader value for GCF calprotectin was performed to predict periodontal diseases. The visual score of GCF calprotectin was highly correlated the IC reader value. IC reader values of GCF calprotectin in periodontitis group were higher than those of healthy group at three dental examination stages and they significantly decreased with periodontal treatments. Visual scores and IC reader values of GCF calprotectin were correlated to the levels of clinical indicators. ROC analysis for GCF calprotectin showed an optimal cutoff value to predict periodontal diseases. Determination of GCF calprotectin using a novel IC chip system is useful for diagnosis of periodontal diseases.
Levman, Jacob E D; Gallego-Ortiz, Cristina; Warner, Ellen; Causer, Petrina; Martel, Anne L
2016-02-01
Magnetic resonance imaging (MRI)-enabled cancer screening has been shown to be a highly sensitive method for the early detection of breast cancer. Computer-aided detection systems have the potential to improve the screening process by standardizing radiologists to a high level of diagnostic accuracy. This retrospective study was approved by the institutional review board of Sunnybrook Health Sciences Centre. This study compares the performance of a proposed method for computer-aided detection (based on the second-order spatial derivative of the relative signal intensity) with the signal enhancement ratio (SER) on MRI-based breast screening examinations. Comparison is performed using receiver operating characteristic (ROC) curve analysis as well as free-response receiver operating characteristic (FROC) curve analysis. A modified computer-aided detection system combining the proposed approach with the SER method is also presented. The proposed method provides improvements in the rates of false positive markings over the SER method in the detection of breast cancer (as assessed by FROC analysis). The modified computer-aided detection system that incorporates both the proposed method and the SER method yields ROC results equal to that produced by SER while simultaneously providing improvements over the SER method in terms of false positives per noncancerous exam. The proposed method for identifying malignancies outperforms the SER method in terms of false positives on a challenging dataset containing many small lesions and may play a useful role in breast cancer screening by MRI as part of a computer-aided detection system.
Gupta, Manoj A; Chakrabarty, Anjan; Halstead, Ruth; Sahni, Mohit; Rangasami, Jayanti; Puliyel, Ashish; Sreenivas, Vishnubhatla; Green, David A; Puliyel, Jacob M
2010-04-26
To validate the SICK scoring system's ability to differentiate between individuals with higher and lower probabilities of death We performed a one year two-centre prospective evaluation of all children aged between one month and 12 years referred to the Paediatric team at St Stephens Hospital in Delhi and admitted to the Paediatric Department at West Middlesex University Hospital in London. We calculated SICK scores at presentation and correlated them with subsequent in-hospital mortality. We used discrimination by areas under receiver operating characteristic (ROC) curves to measure performance. We prospectively evaluated 3895 children in Delhi and 1473 children in London. The areas under the ROC curves were 84.8% in Delhi, 81.0% in London and 84.1% (95% CI 77.4-90.8%) for combined data. Hosmer-Lemeshow goodness of fit for the combined data was good (Hosmer-Lemeshow Chi-square=2.13 (p=0.345). We propose the SICK score as a useful triage tool at initial presentation and highlight its particular suitability for resource poor settings.
2010-01-01
Objective To validate the SICK scoring system's ability to differentiate between individuals with higher and lower probabilities of death Method We performed a one year two-centre prospective evaluation of all children aged between one month and 12 years referred to the Paediatric team at St Stephens Hospital in Delhi and admitted to the Paediatric Department at West Middlesex University Hospital in London. We calculated SICK scores at presentation and correlated them with subsequent in-hospital mortality. We used discrimination by areas under receiver operating characteristic (ROC) curves to measure performance. Results We prospectively evaluated 3895 children in Delhi and 1473 children in London. The areas under the ROC curves were 84.8% in Delhi, 81.0% in London and 84.1% (95% CI 77.4 - 90.8%) for combined data. Hosmer-Lemeshow goodness of fit for the combined data was good (Hosmer-Lemeshow Chi-square = 2.13 (p = 0.345). Conclusions We propose the SICK score as a useful triage tool at initial presentation and highlight its particular suitability for resource poor settings. PMID:20420670
Techatraisak, Kitirat; Wongmeerit, Krissanee; Dangrat, Chongdee; Wongwananuruk, Thanyarat; Indhavivadhana, Suchada
2016-01-01
To evaluate the relationship between measures of body adiposity and visceral adiposity index (VAI) and risk of metabolic syndrome (MS) and to identify the optimal cut-off points of each measurement in Thai polycystic ovary syndrome (PCOS). A cross-sectional study was completed physical examination, fasting plasma glucose, lipid profiles of 399 PCOS and 42 age-matched normal controls. Body mass index (BMI), waist-to-hip ratio (WHR), waist-to-height ratio (WHtR) and VAI were calculated. Associations between different measures and MS were evaluated and the receiver-operating characteristic (ROC) curve was performed to determine appropriate cut-off points for identifying MS. Percentage of MS in PCOS was 24.6%, whereas none MS in controls. Previously recommended cut-off values for body adiposity and VAI were significantly associated with MS. ROC curve analysis of the only PCOS showed newly obtained optimal cut-off points for BMI and VAI of ≥28 kg/m(2) (AUC = 0.90) and >5.6 (AUC = 0.94), respectively. Values found to be more accurate than the original ones. VAI was the best predictor, followed by BMI and WHtR. All body adiposity and VAI parameters can predict the risk of MS. Optimal values for Thai PCOS were ≥28 kg/m(2) for BMI, ≥0.85 for WHR, ≥0.5 for WHtR and >5.6 for VAI.
Poole, Kerry; Elms, Joanne; Mason, Howard
2006-10-01
The aim was to investigate whether the use of infra-red thermography (I-R) and measurement of temperature gradients along the finger could improve the diagnostic accuracy of cold-provocation testing (15 degrees C for 5 min) in vascular hand-arm vibration syndrome (HAVS). Twenty-one controls and 33 individuals with stages 2/3V HAVS were studied. The standard measurement of time to rewarm by 4 degrees C (T4 degrees C) and temperature gradients between the finger tip, base and middle (measured using I-R) were calculated. Receiver Operating Characteristics (ROC) analysis to distinguish between the two groups revealed that for T4 degrees C the area under the ROC curve was not statistically significantly different from 0.5 (0.64 95% confidence interval 0.49-0.76). The difference between the tip and middle portion of the finger during the sixth minute of recovery was the most promising gradient with an area of 0.76 (95% confidence interval 0.62-0.87), and sensitivity and specificity of 57.6% and 85.7% respectively. However, this was not significantly different from that for the time to rewarm by 4 degrees C. In conclusion, the cold-provocation test used in this study does not appear to discriminate between individuals with stage 2/3V HAVS and controls and this is not improved by the measurement of temperature gradients along the fingers using I-R.
Lee, Jae-Hong; Kim, Do-Hyung; Jeong, Seong-Nyum; Choi, Seong-Ho
2018-04-01
The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.