NASA Technical Reports Server (NTRS)
Callender, E. David; Steinbacher, Jody
1989-01-01
This is the fifth of five volumes on Information System Life-Cycle and Documentation Standards. This volume provides a well organized, easily used standard for management control and status reports used in monitoring and controlling the management, development, and assurance of informations systems and software, hardware, and operational procedures components, and related processes.
Aircraft Electrical Systems Specialist (AFSC 42350), Volumes 1-3, and Change Supplement, Volume 3.
ERIC Educational Resources Information Center
Savage, Leslie R.
This three-volume student text is designed for use by Air Force personnel enrolled in a self-study extension course for aircraft electrical systems specialists. Covered in the individual volumes are career field fundamentals, electrical systems and test equipment, and aircraft control and warning systems. Each volume in the set contains a series…
INTEGRATED AIR POLLUTION CONTROL SYSTEM VERSION 5.0 - VOLUME 2: TECHNICAL DOCUMENTATION
The three volume report and two diskettes document the Integrated Air Pollution Control System (IAPCS), developed for the U.S. EPA to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, an eq...
INTEGRATED AIR POLLUTION CONTROL SYSTEM VERSION 5.0 - VOLUME 3: PROGRAMMER'S MAINTENANCE MANUAL
The three volume report and two diskettes document the Integrated Air Pollution Control System (IAPCS), developed for the U.S. EPA to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, an eq...
INTEGRATED AIR POLLUTION CONTROL SYSTEM VERSION 5.0 - VOLUME 1: USER'S GUIDE
The three volume report and two diskettes document the Integrated Air Pollution Control System (IAPCS), developed for the U.S. EPA to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, an eq...
Technology Transfer Program (TTP). Quality Assurance System. Volume 2. Appendices
1980-03-03
LSCo Report No. - 2X23-5.1-4-I TECHNOLOGY TRANSFER PROGRAM (TTP) FINAL REPORT QUALITY ASSURANCE SYSTEM Appendix A Accuracy Control System QUALITY...4-1 TECHNOLOGY TRANSFER PROGRAM (TTP) FINAL REPORT QUALITY ASSURANCE SYSTEM Appendix A Accuracy Control System QUALITY ASSURANCE VOLUME 2 APPENDICES...prepared by: Livingston Shipbuilding Company Orange, Texas March 3, 1980 APPENDIX A ACCURACY CONTROL SYSTEM . IIII MARINE TECHNOLOGY. INC. HP-121
DOT National Transportation Integrated Search
1974-08-01
Volume 4 describes the automation requirements. A presentation of automation requirements is made for an advanced air traffic management system in terms of controller work force, computer resources, controller productivity, system manning, failure ef...
Railroad Classification Yard Technology Manual: Volume II : Yard Computer Systems
DOT National Transportation Integrated Search
1981-08-01
This volume (Volume II) of the Railroad Classification Yard Technology Manual documents the railroad classification yard computer systems methodology. The subjects covered are: functional description of process control and inventory computer systems,...
DOT National Transportation Integrated Search
1974-08-01
Volume 4 describes the automation requirements. A presentation of automation requirements is made for an advanced air traffic management system in terms of controller work for-e, computer resources, controller productivity, system manning, failure ef...
Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results
NASA Technical Reports Server (NTRS)
Glass, B. J. (Editor)
1992-01-01
The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.
Thermal Expert System (TEXSYS): Systems automony demonstration project, volume 1. Overview
NASA Technical Reports Server (NTRS)
Glass, B. J. (Editor)
1992-01-01
The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS test bed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.
Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results
NASA Astrophysics Data System (ADS)
Glass, B. J.
1992-10-01
The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.
DOT National Transportation Integrated Search
1974-08-01
Volume 4 describes the automation requirements. A presentation of automation requirements is made for an advanced air traffic management system in terms of controller work for-e, computer resources, controller productivity, system manning, failure ef...
Systems and methods for the detection of low-level harmful substances in a large volume of fluid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carpenter, Michael V.; Roybal, Lyle G.; Lindquist, Alan
A method and device for the detection of low-level harmful substances in a large volume of fluid comprising using a concentrator system to produce a retentate and analyzing the retentate for the presence of at least one harmful substance. The concentrator system performs a method comprising pumping at least 10 liters of fluid from a sample source through a filter. While pumping, the concentrator system diverts retentate from the filter into a container. The concentrator system also recirculates at least part of the retentate in the container again through the filter. The concentrator system controls the speed of the pumpmore » with a control system thereby maintaining a fluid pressure less than 25 psi during the pumping of the fluid; monitors the quantity of retentate within the container with a control system, and maintains a reduced volume level of retentate and a target volume of retentate.« less
NASA Technical Reports Server (NTRS)
Bodley, C. S.; Devers, D. A.; Park, C. A.
1975-01-01
A theoretical development and associated digital computer program system is presented. The dynamic system (spacecraft) is modeled as an assembly of rigid and/or flexible bodies not necessarily in a topological tree configuration. The computer program system may be used to investigate total system dynamic characteristics including interaction effects between rigid and/or flexible bodies, control systems, and a wide range of environmental loadings. Additionally, the program system may be used for design of attitude control systems and for evaluation of total dynamic system performance including time domain response and frequency domain stability analyses. Volume 1 presents the theoretical developments including a description of the physical system, the equations of dynamic equilibrium, discussion of kinematics and system topology, a complete treatment of momentum wheel coupling, and a discussion of gravity gradient and environmental effects. Volume 2, is a program users' guide and includes a description of the overall digital program code, individual subroutines and a description of required program input and generated program output. Volume 3 presents the results of selected demonstration problems that illustrate all program system capabilities.
NASA Technical Reports Server (NTRS)
Lin, Shian-Jiann; DaSilva, Arlindo; Atlas, Robert (Technical Monitor)
2001-01-01
Toward the development of a finite-volume Data Assimilation System (fvDAS), a consistent finite-volume methodology is developed for interfacing the NASA/DAO's Physical Space Statistical Analysis System (PSAS) to the joint NASA/NCAR finite volume CCM3 (fvCCM3). To take advantage of the Lagrangian control-volume vertical coordinate of the fvCCM3, a novel "shaving" method is applied to the lowest few model layers to reflect the surface pressure changes as implied by the final analysis. Analysis increments (from PSAS) to the upper air variables are then consistently put onto the Lagrangian layers as adjustments to the volume-mean quantities during the analysis cycle. This approach is demonstrated to be superior to the conventional method of using independently computed "tendency terms" for surface pressure and upper air prognostic variables.
Code of Federal Regulations, 2012 CFR
2012-07-01
... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...
Code of Federal Regulations, 2013 CFR
2013-07-01
... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...
Code of Federal Regulations, 2011 CFR
2011-07-01
... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...
Code of Federal Regulations, 2010 CFR
2010-07-01
... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...
Petruck, A; Holtmeier, E; Redder, A; Teichgräber, B
2003-01-01
Emschergenossenschaft and Lippeverband have developed a method to use radar-measured precipitation as an input for a real-time control of a combined sewer system containing several overflow structures. Two real-time control strategies have been developed and tested, one is solely volume-based, the other is volume and pollution-based. The system has been implemented in a pilot study in Gelsenkirchen, Germany. During the project the system was optimised and is now in constant operation. It was found, that the volume of combined sewage overflow could be reduced by 5 per cent per year. This was also found in simulations carried out in similar catchment areas. Most of the potential of improvement can already be achieved by local pollution-based control strategies.
NASA Technical Reports Server (NTRS)
1972-01-01
Major study areas treated in this volume are: 1) operations and control and 2) the telecommunication service system. The TDRS orbit selection, orbital deployment, ground station visibility, sequence of events from launch to final orbit position, and TDRS control center functions required for stationkeeping, repositioning, attitude control, and antenna pointing are briefly treated as part of the operations and control section. The last topic of this section concerns the operations required for efficiently providing the TDRSS user telecommunication services. The discussion treats functions of the GSFC control and data processing facility, ground station, and TDRS control center. The second major portion of this volume deals with the Telecommunication Service System (TSS) which consists of the ground station, TDRS communication equipment and the user transceiver. A summary of the requirements and objectives for the telecommunication services and a brief summary of the TSS capabilities is followed by communication system analysis, signal design, and equipment design. Finally, descriptions of the three TSS elements are presented.
1977-04-01
U* AFFDL-TR-77-7 0 VOLUME III " VALIDATION OF MIL-F-9490D - GENERAL SPECIFICATION FOR FLIGHT CONTROL SYSTEM "FOR PILOTED MILITARY AIRCRAFT VOLUME...ý A1O 1 C I\\.FFBL Ti(-77-7. Vol. III f Validatio~n of UL-P-9-490D#,*. General Spacificatior "~inal 1’l -_t e for Flight ContrsA Zyn’om for Piloted...cation MIL-F-9490D (USAF), "Flight Control Systems - Design, Installation and Test of Piloted Aircraft, General Specifications for," dated 6 June 1975, by
Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup
2013-06-01
This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E.; Gonzalez, Manuel E.; Llewellyn, Brian C.; Bloys, James B.
2008-10-28
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Gonzalez, Manuel E [Kingwood, TX; Llewellyn, Brian C [Kingwood, TX; Bloys, James B [Katy, TX; Coates, Don M [Santa Fe, NM
2011-05-31
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Gonzalez, Manuel E [Kingwood, TX; Llewellyn, Brian C [Kingwood, TX; Bloys, James B [Katy, TX
2011-01-18
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E.; Gonzalez, Manuel E.; Llewellyn, Brian C.; Bloys, James B.
2010-06-29
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Controlling the pressure within an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Gonzalez, Manuel E [Kingwood, NM; Llewellyn, Brian C [Kingwood, TX; Bloys, James B [Katy, TX; Coates, Don M [Santa Fe, NM
2011-06-21
A process is described for replacing at least a portion of the liquid within the annular volume of a casing system within a wellbore with a second liquid. The second liquid is preselected to provide a measure of control of the pressure within the annular volume as the fluid within the volume is being heated.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 1
NASA Astrophysics Data System (ADS)
1984-08-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 4 contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the first of five books of volume four. It contains structural design criteria, generator step-up transformer specs, specs for design, fabrication and testing of the system, specs for the ground control enclosure, systems specs, slip ring specs, and control system specs.
Mod-5A Wind Turbine Generator Program Design Report. Volume 4: Drawings and Specifications, Book 1
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 4 contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the first of five books of volume four. It contains structural design criteria, generator step-up transformer specs, specs for design, fabrication and testing of the system, specs for the ground control enclosure, systems specs, slip ring specs, and control system specs.
NASA Technical Reports Server (NTRS)
Taylor, B.; Brissette, R.; Humphrey, A.; Morris, J.; Luger, J.; Swift, W.
1978-01-01
The HEAO-B Gas Control System consists of a high pressure gas storage supply together with distribution and regulation assemblies and their associated electronics for management of gas required for HEAO-B X-ray counter experiments. The Gas Control System replenishes a gas mixture (82 percent argon, 12.3 percent carbon dioxide, 5.7 percent xenon) in the counter volumes which is lost by: diffusion through controlled leakage plugs, diffusion through counter windows, and consumption resulting from periodic purges. The gas density in each counter volume is maintained constant to within 0.25 percent by comparison with a sealed reference volume. The system is fully redundant, capable of operating at atmospheric pressure as well as in a vacuum, contains interlocks which shut down gas flow in the event of either leakage or excessive pressure, and is able to shut down counter high voltage if counter pressure is abnormally low. The system is electronically controlled by ground command and self-sustaining in orbit for a period of at least one year.
First CLIPS Conference Proceedings, volume 2
NASA Technical Reports Server (NTRS)
1990-01-01
The topics of volume 2 of First CLIPS Conference are associated with following applications: quality control; intelligent data bases and networks; Space Station Freedom; Space Shuttle and satellite; user interface; artificial neural systems and fuzzy logic; parallel and distributed processing; enchancements to CLIPS; aerospace; simulation and defense; advisory systems and tutors; and intelligent control.
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's Office of Aeronautics and Space Technology conducted a workshop on technology for space station evolution 16-19 Jan. 1990. The purpose of the workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 2 consists of the technology discipline sections for the Data Management System and the Environmental Control and Life Support Systems. For each technology discipline, there is a Level 3 subsystem description, along with the invited papers.
Programmable temperature control system for biological materials
NASA Technical Reports Server (NTRS)
Anselmo, V. J.; Harrison, R. G.; Rinfret, A. P.
1982-01-01
A system was constructed which allows programmable temperature-time control for a 5 cu cm sample volume of arbitrary biological material. The system also measures the parameters necessary for the determination of the sample volume specific heat and thermal conductivity as a function of temperature, and provides a detailed measurement of the temperature during phase change and a means of calculating the heat of the phase change. Steady-state and dynamic temperature control is obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container is totally immersed into a cold heat sink. Using a mixture of dry ice and alcohol at 79 C, the sample volume can be controlled from +40 to -60 C at rates from steady state to + or - 65 C/min. Steady-state temperature precision is better than 0.2 C, while the dynamic capability depends on the temperature rate of change as well as the mass of both the sample and the container.
ERIC Educational Resources Information Center
Weisburd, Melvin I.
The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…
Fuld, Matthew K.; Grout, Randall; Guo, Junfeng; Morgan, John H.; Hoffman, Eric A.
2013-01-01
Rationale and Objectives Multidetector-row Computed Tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics) and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breath-hold at a standardized volume. Materials and Methods A computer monitored turbine-based flow meter system was developed to control patient breath-holds and facilitate static imaging at fixed percentages of the vital capacity. Due to calibration challenges with gas density changes during multi-breath xenon-CT an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. Results The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was −9 ml (−169, 151); for TLC alone 6 ml (−164, 177); for FRC alone, −23 ml (−172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject non-compliance with verbal instruction and gas leaks around the mouthpiece. Conclusion We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon-CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multi-breath wash-in xenon-CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon-CT method for assessing regional lung function, while not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon-CT measures can be validated. PMID:22555001
Fuld, Matthew K; Grout, Randall W; Guo, Junfeng; Morgan, John H; Hoffman, Eric A
2012-08-01
Multidetector-row computed tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics), and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breathhold at a standardized volume. A computer monitored turbine-based flow meter system was developed to control patient breathholds and facilitate static imaging at fixed percentages of the vital capacity. Because of calibration challenges with gas density changes during multibreath xenon CT, an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was -9 mL (-169, 151); for total lung capacity alone 6 mL (-164, 177); for functional residual capacity alone, -23 mL (-172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject noncompliance with verbal instruction and gas leaks around the mouthpiece. We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multibreath wash-in xenon CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon CT method for assessing regional lung function, although not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon CT measures can be validated. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Karl, D. R.
1972-01-01
An evaluation was made of the feasibility of utilizing a simplified man machine interface concept to manage and control a complex space system involving multiple redundant computers that control multiple redundant subsystems. The concept involves the use of a CRT for display and a simple keyboard for control, with a tree-type control logic for accessing and controlling mission, systems, and subsystem elements. The concept was evaluated in terms of the Phase B space shuttle orbiter, to utilize the wide scope of data management and subsystem control inherent in the central data management subsystem provided by the Phase B design philosophy. Results of these investigations are reported in four volumes.
Flight control systems properties and problems, volume 1
NASA Technical Reports Server (NTRS)
Mcruer, D. T.; Johnston, D. E.
1975-01-01
This volume contains a delineation of fundamental and mechanization-specific flight control characteristics and problems gleaned from many sources and spanning a period of over two decades. It is organized to present and discuss first some fundamental, generic problems of closed-loop flight control systems involving numerator characteristics (quadratic dipoles, non-minimum phase roots, and intentionally introduced zeros). Next the principal elements of the largely mechanical primary flight control system are reviewed with particular emphasis on the influence of nonlinearities. The characteristics and problems of augmentation (damping, stability, and feel) system mechanizations are then dealt with. The particular idiosyncracies of automatic control actuation and command augmentation schemes are stressed, because they constitute the major interfaces with the primary flight control system and an often highly variable vehicle response.
NASA Technical Reports Server (NTRS)
Hynes, Charles S.; Hardy, Gordon H.; Sherry, Lance
2007-01-01
Volume I of this report presents a new method for synthesizing hybrid systems directly from design requirements, and applies the method to design of a hybrid system for longitudinal control of transport aircraft. The resulting system satisfies general requirement for safety and effectiveness specified a priori, enabling formal validation to be achieved. Volume II contains seven appendices intended to make the report accessible to readers with backgrounds in human factors, fli ght dynamics and control. and formal logic. Major design goals are (1) system desi g n integrity based on proof of correctness at the design level, (2), significant simplification and cost reduction in system development and certification, and (3) improved operational efficiency, with significant alleviation of human-factors problems encountered by pilots in current transport aircraft. This report provides for the first time a firm technical basis for criteria governing design and certification of avionic systems for transport aircraft. It should be of primary interest to designers of next-generation avionic systems.
NASA Technical Reports Server (NTRS)
Hynes, Charles S.; Hardy, Gordon H.; Sherry, Lance
2007-01-01
Volume I of this report presents a new method for synthesizing hybrid systems directly from desi gn requirements, and applies the method to design of a hybrid system for longitudinal control of transport aircraft. The resulting system satisfies general requirement for safety and effectiveness specified a priori, enabling formal validation to be achieved. Volume II contains seven appendices intended to make the report accessible to readers with backgrounds in human factors, flight dynamics and control, and formal logic. Major design goals are (1) system design integrity based on proof of correctness at the design level, (2) significant simplification and cost reduction in system development and certification, and (3) improved operational efficiency, with significant alleviation of human-factors problems encountered by pilots in current transport aircraft. This report provides for the first time a firm technical basis for criteria governing design and certification of avionic systems for transport aircraft. It should be of primary interest to designers of next-generation avionic systems.
A controlled rate freeze/thaw system for cryopreservation of biological materials
NASA Technical Reports Server (NTRS)
Anselmo, V. J.; Harrison, R. G.
1979-01-01
A system which allows programmable temperature-time control for a 5 cc sample volume of an arbitrary biological material was constructed. Steady state and dynamic temperature control was obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container was totally immersed into a cold heat sink. Sample volume thermodynamic property data were obtained by measurements of heater power and heat flux through the container walls. Using a mixture of dry ice and alcohol at -79 C, sample volume was controlled from +40 C to -60 C at rates from steady state to + or - 65 C/min. Steady state temperature precision was better than 0.2 C while the dynamic capability depends on the temperature rate of change as well as the thermal mass of the sample and the container.
Mod-2 wind turbine system development. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1982-01-01
The development of the MOD-2 wind turbine through acceptance testing and initial operational evaluation is documented. Pitch control hydraulic system, yaw control system, drive train, electrical power station, control system, operations and maintenance experience, and availability are discussed.
Traffic flow forecasting for intelligent transportation systems.
DOT National Transportation Integrated Search
1995-01-01
The capability to forecast traffic volume in an operational setting has been identified as a critical need for intelligent transportation systems (ITS). In particular, traffic volume forecasts will directly support proactive traffic control and accur...
NASA Technical Reports Server (NTRS)
Taube, L. J.
1972-01-01
This volume contains cost, schedule, and technical information on the following B-70 aircraft subsystems: air induction system, flight control, personnel accommodation and escape, alighting and arresting, mission and traffic control, flight indication, test instrumentation, and installation, checkout, and pre-flight.
Bernard, D J; Casto, J M; Ball, G F
1993-08-22
Previous studies have found that the volume of several song control nuclei is larger in male songbirds than in female songbirds. The degree of this volumetric sex difference within a given species appears to be systematically related to the degree of the behavioral sex difference. The largest volumetric differences have been reported in species in which the male sings and the female sings little, if at all, and the smallest sex differences in volume have been reported in species in which males and females both sing in nearly equal amounts. We compared the volume of three song control nuclei in male and female European starlings (Sturnus vulgaris), a species in which females are known to sing, though at a much lower rate than males. We investigated the volume of hyperstriatum ventrale, pars caudale, nucleus robustus archistriatalis, and area X of the lobus parolfactorius as defined with the use of a Nissl stain. In addition, we measured the volume of area X as defined by the density of muscarinic cholinergic receptors visualized by in vitro receptor autoradiographic methods. The volumes of all three of the song nuclei, as defined by Nissl staining, are significantly larger in males than in females. For area X, Nissl staining and receptor autoradiography indicate the same significant volumetric sex difference. The three nuclei are approximately one and one half to two times larger in males than in females, a degree of dimorphism that is intermediate to those reported for other species. Previous investigations of sex differences in the avian vocal control system have used only Nissl stains to define nuclear volumes. We demonstrate in this paper that receptor autoradiography can be used to assess dimorphisms in nuclear volume. Broad application of this approach to a number of neurotransmitter receptor systems will better characterize the dimorphisms in the song system, and therefore will provide greater insight into the neuroanatomical and neurochemical control of birdsong.
NASA Technical Reports Server (NTRS)
1988-01-01
The Conference Proceedings is a compilation of over 30 technical papers presented which report on the advances in rotorcraft technical knowledge resulting from NASA, Army, and industry research programs over the last 5 to 10 years. Topics addressed in this volume include: materials and structures; propulsion and drive systems; flight dynamics and control; and acoustics.
Contained radiological analytical chemistry module
Barney, David M.
1989-01-01
A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.
Contained radiological analytical chemistry module
Barney, David M.
1990-01-01
A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.
Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 3
NASA Technical Reports Server (NTRS)
Prust, Chet D.; Hartman, Dan W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 3 continues the presentation of IOA worksheets.
Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 2
NASA Technical Reports Server (NTRS)
Prust, Chet D.; Hartman, Dan W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 2 continues the presentation of IOA worksheets.
Circuit compliance compensation in lung protective ventilation.
Masselli, Grazia Maria Pia; Silvestri, Sergio; Sciuto, Salvatore Andrea; Cappa, Paolo
2006-01-01
Lung protective ventilation utilizes low tidal volumes to ventilate patients with severe lung pathologies. The compensation of breathing circuit effects, i.e. those induced by compressible volume of the circuit, results particularly critical in the calculation of the actual tidal volume delivered to patient's respiratory system which in turns is responsible of the level of permissive hypercapnia. The present work analyzes the applicability of the equation for circuit compressible volume compensation in the case of pressure and volume controlled lung protective ventilation. Experimental tests conducted in-vitro show that the actual tidal volume can be reliably estimated if the compliance of the breathing circuit is measured with the same parameters and ventilation technique that will be utilized in lung protective ventilation. Differences between volume and pressure controlled ventilation are also quantitatively assessed showing that pressure controlled ventilation allows a more reliable compensation of breathing circuit compressible volume.
Chamber for the optical manipulation of microscopic particles
Buican, Tudor N.; Upham, Bryan D.
1992-01-01
A particle control chamber enables experiments to be carried out on biological cells and the like using a laser system to trap and manipulate the particles. A manipulation chamber provides a plurality of inlet and outlet ports for the particles and for fluids used to control or to contact the particles. A central manipulation area is optically accessible by the laser and includes first enlarged volumes for containing a selected number of particles for experimentation. A number of first enlarged volumes are connected by flow channels through second enlarged volumes. The second enlarged volumes act as bubble valves for controlling the interconnections between the first enlarged volumes. Electrode surfaces may be applied above the first enlarged volumes to enable experimentation using the application of electric fields within the first enlarged volumes. A variety of chemical and environmental conditions may be established within individual first enlarged volumes to enable experimental conditions for small scale cellular interactions.
The effect of closed system suction on airway pressures when using the Servo 300 ventilator.
Frengley, R W; Closey, D N; Sleigh, J W; Torrance, J M
2001-12-01
To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically ventilated with a Servo 300 ventilator set to one of three ventilation modes: volume-control, pressure-control or CPAP/pressure support. Airway pressures were measured via a 4 French electronic pressure transducer in both proximal and distal airways. Following insertion of the suction catheter, end-expiratory pressure increased significantly (p < 0.001) in both pressure-control and volume-control ventilation. This increase was greatest (p = 0.018) in volume-control mode (2.7 +/- 1.7 cmH2O). On performing a five second suction, airway pressure decreased in all modes, however the lowest airway pressure in volume-control mode (-4.9 +/- 4.0 cmH2O) was significantly (p = 0.001) less than the lowest airway pressure recorded in either pressure-control (0.8 +/- 1.9 cmH2O) or CPAP/pressure support (0.4 +/- 2.8 cmH2O) modes. In CPAP/pressure support mode, 13 of the 16 patients experienced a positive pressure 'breath' at the end of suctioning with airway pressures rising to 21 +/- 1.6 cmH2O. Closed system suctioning in volume control ventilation may result in elevations of end-expiratory pressure following catheter insertion and subatmospheric airway pressures during suctioning. Pressure control ventilation produces less elevation of end-expiratory pressure following catheter insertion and is less likely to be associated with subatmospheric airway pressures during suctioning. CPAP/pressure support has no effect on end-expiratory pressure following catheter insertion and subatmospheric airway pressures are largely avoided during suctioning.
Numerical Modeling of Cavitating Venturi: A Flow Control Element of Propulsion System
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Saxon, Jeff (Technical Monitor)
2002-01-01
In a propulsion system, the propellant flow and mixture ratio could be controlled either by variable area flow control valves or by passive flow control elements such as cavitating venturies. Cavitating venturies maintain constant propellant flowrate for fixed inlet conditions (pressure and temperature) and wide range of outlet pressures, thereby maintain constant, engine thrust and mixture ratio. The flowrate through the venturi reaches a constant value and becomes independent of outlet pressure when the pressure at throat becomes equal to vapor pressure. In order to develop a numerical model of propulsion system, it is necessary to model cavitating venturies in propellant feed systems. This paper presents a finite volume model of flow network of a cavitating venturi. The venturi was discretized into a number of control volumes and mass, momentum and energy conservation equations in each control volume are simultaneously solved to calculate one-dimensional pressure, density, and flowrate and temperature distribution. The numerical model predicts cavitations at the throat when outlet pressure was gradually reduced. Once cavitation starts, with further reduction of downstream pressure, no change in flowrate is found. The numerical predictions have been compared with test data and empirical equation based on Bernoulli's equation.
Control Systems for Information Systems Development Projects (Part I)
ERIC Educational Resources Information Center
Dickson, Gary W.
1970-01-01
Discusses control of management information systems and finds a similarity in management of research and development activity. Part II will appear in AEDS Journal, Volume 4, number 2, December 1970. (JF)
Technology for Space Station Evolution. Volume 5: Structures and Materials/Thermal Control System
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution on 16-19 Jan. 1990. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 5 consists of the technology discipline sections for Structures/Materials and the Thermal Control System. For each technology discipline, there is a level 3 subsystem description, along with papers.
Theoretical Evaluation of Electroactive Polymer Based Micropump Diaphragm for Air Flow Control
NASA Technical Reports Server (NTRS)
Xu, Tian-Bing; Su, Ji; Zhang, Qiming
2004-01-01
An electroactive polymer (EAP), high energy electron irradiated poly(vinylidene fluoride-trifluoroethylene) [P(VDFTrFE)] copolymer, based actuation micropump diaphragm (PAMPD) have been developed for air flow control. The displacement strokes and profiles as a function of amplifier and frequency of electric field have been characterized. The volume stroke rates (volume rate) as function of electric field, driving frequency have been theoretically evaluated, too. The PAMPD exhibits high volume rate. It is easily tuned with varying of either amplitude or frequency of the applied electric field. In addition, the performance of the diaphragms were modeled and the agreement between the modeling results and experimental data confirms that the response of the diaphragms follow the design parameters. The results demonstrated that the diaphragm can fit some future aerospace applications to replace the traditional complex mechanical systems, increase the control capability and reduce the weight of the future air dynamic control systems. KEYWORDS: Electroactive polymer (EAP), micropump, diaphragm, actuation, displacement, volume rate, pumping speed, clamping ratio.
High volume data storage architecture analysis
NASA Technical Reports Server (NTRS)
Malik, James M.
1990-01-01
A High Volume Data Storage Architecture Analysis was conducted. The results, presented in this report, will be applied to problems of high volume data requirements such as those anticipated for the Space Station Control Center. High volume data storage systems at several different sites were analyzed for archive capacity, storage hierarchy and migration philosophy, and retrieval capabilities. Proposed architectures were solicited from the sites selected for in-depth analysis. Model architectures for a hypothetical data archiving system, for a high speed file server, and for high volume data storage are attached.
A computer system for analysis and transmission of spirometry waveforms using volume sampling.
Ostler, D V; Gardner, R M; Crapo, R O
1984-06-01
A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This military-developed text consists of four volumes of materials for use by those studying to become apprentice heating system specialists. Covered in the individual volumes are the following topics: related subjects (basic electricity, electrical controls, pipe and copper tubing, the principles of heating, fuels, and fuel systems); heating…
DOT National Transportation Integrated Search
1975-07-01
The volume presents the results of the quantitative analyses of the O'Hare ASTC System operations. The operations environments for the periods selected for detailed analysis of the ASDE films and controller communications recording are described. Fol...
Jenke, Christoph; Pallejà Rubio, Jaume; Kibler, Sebastian; Häfner, Johannes; Richter, Martin; Kutter, Christoph
2017-01-01
With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout—differential pressure based flow sensors and thermal calorimetric flow sensors—are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved. PMID:28368344
Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM
2012-06-19
A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
Thornberg, Steven M; Brown, Jason
2015-02-17
A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
International training course on nuclear materials accountability for safeguards purposes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-12-01
The two volumes of this report incorporate all lectures and presentations at the International Training Course on Nuclear Materials Accountability and Control for Safeguards Purposes, held May 27-June 6, 1980, at the Bishop's Lodge near Santa Fe, New Mexico. The course, authorized by the US Nuclear Non-Proliferation Act and sponsored by the US Department of Energy in cooperation with the International Atomic Energy Agency, was developed to provide practical training in the design, implementation, and operation of a National system of nuclear materials accountability and control that satisfies both National and IAEA International safeguards objectives. Volume I, covering the firstmore » week of the course, presents the background, requirements, and general features of material accounting and control in modern safeguard systems. Volume II, covering the second week of the course, provides more detailed information on measurement methods and instruments, practical experience at power reactor and research reactor facilities, and examples of operating state systems of accountability and control.« less
Bohachevsky, I.O.; Torrey, M.D.
1986-06-10
An underwater pulsed hydrojet propulsion system is provided for accelerating and propelling a projectile or other vessel. A reactant, such as lithium, is fluidized and injected into a water volume. The resulting reaction produces an energy density in a time effective to form a steam pocket. Thrust flaps or baffles direct the pressure from the steam pocket toward an exit nozzle for accelerating a water volume to create thrust. A control system regulates the dispersion of reactant to control thrust characteristics.
1977-09-01
vdI1 SCCLRITY CLASSIFICATIOlN OF THIS PAGE(When DMae ffnifod) Block 20 (Cont): ------ AFCS control laws are examined. Associated documents are: Volume I...both the HII gain and LO gain outputs. Both were traced to defective components. In the former, the HII gain output amplifier AR4 was replaced and in...the latter, a relay in the relay module was defective . 613 S. . ......-. . . 6.2.2.4 ExcessivC Time Lag During the BARO altitude hold evaluation, the
Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 4
NASA Technical Reports Server (NTRS)
Prust, Chet D.; Hartman, Dan W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 4 continues the presentation of IOA worksheets and contains the potential critical items list.
INTEGRATED AIR POLLUTION CONTROL SYSTEM, VERSION 4.0 - VOLUME 1: USER'S GUIDE
The Integrated Air Pollution Control System (IAPCS) was developed for the U.S. EPA's Air and Energy Engineering Research Laboratory to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, and ...
Engineering data compendium. Human perception and performance, volume 3
NASA Technical Reports Server (NTRS)
Boff, Kenneth R. (Editor); Lincoln, Janet E. (Editor)
1988-01-01
The concept underlying the Engineering Data Compendium was the product of a research and development program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design of military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by system designers. The present four volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is Volume 3, containing sections on Human Language Processing, Operator Motion Control, Effects of Environmental Stressors, Display Interfaces, and Control Interfaces (Real/Virtual).
NASA Technical Reports Server (NTRS)
Mckee, James W.
1990-01-01
This volume (2 of 4) contains the specification, structured flow charts, and code listing for the protocol. The purpose of an autonomous power system on a spacecraft is to relieve humans from having to continuously monitor and control the generation, storage, and distribution of power in the craft. This implies that algorithms will have been developed to monitor and control the power system. The power system will contain computers on which the algorithms run. There should be one control computer system that makes the high level decisions and sends commands to and receive data from the other distributed computers. This will require a communications network and an efficient protocol by which the computers will communicate. One of the major requirements on the protocol is that it be real time because of the need to control the power elements.
NASA Technical Reports Server (NTRS)
1981-01-01
The software developed to simulate the ground control point navigation system is described. The Ground Control Point Simulation Program (GCPSIM) is designed as an analysis tool to predict the performance of the navigation system. The system consists of two star trackers, a global positioning system receiver, a gyro package, and a landmark tracker.
Control of volume resistivity in inorganic organic separators
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Manzo, M. A.
1979-01-01
Control of resistivity in NASA inorganic-organic separators is achieved by incorporating small percentages of high surface area, fine particle silica with other ingredients in the separator coating. The volume resistivity is predictable from the surface area of filler particles in the coating. The approach is applied to two polymer- plasticizer -filler coating systems, where the filler content of each is below the generally acknowledged critical pigment volume concentration of the coating. Application of these coating systems to 0.0254 cm thick (10-mil) fuel cell grade asbestos sheet produces inexpensive, flexible, microporous separators that perform as well as the original inorganic-organic concept, the Astropower separator.
Cardiovascular simulator improvement: pressure versus volume loop assessment.
Fonseca, Jeison; Andrade, Aron; Nicolosi, Denys E C; Biscegli, José F; Leme, Juliana; Legendre, Daniel; Bock, Eduardo; Lucchi, Julio Cesar
2011-05-01
This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Proctor, B. W.; Reysa, R. P.; Russell, D. J.
1975-01-01
A review of crew appliance related literature was made to provide background engineering information for development of conceptual appliance systems for the shuttle orbiter and the modular space station. From this review, a file containing abstracts of 299 appliance-related documents coded according to subject was developed along with a computerized bibliography of 682 references. Trade studies were conducted using information from these references to determine the optimum concepts to satisfy the shuttle and space station mission requirements. An appliance system was devised for each vehicle which has minimum impact to the respective environmental control system with the smallest possible weight, volume, and electrical penalty. Engineering parameters for each appliance concept considered are presented along with the total thermal and electrical loads and weight and volume penalties for each of the optimized appliance systems.
INTEGRATED AIR POLLUTION CONTROL SYSTEM, VERSION 4.0 - VOLUME 3: PROGRAMMER'S MAINTENACE MANUAL
The Integrated Air Pollution Control System (IAPCS) was developed for the U.S. EPA's Air and Energy Engineering Research Laboratory to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, and ...
INTEGRATED AIR POLLUTION CONTROL SYSTEM, VERSION 4.0 - VOLUME 2: TECHNICAL DOCUMENTATION MANUAL
The Integrated Air Pollution Control System (IAPCS) was developed for the U.S. EPA's Air and Energy Engineering Research Laboratory to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, and ...
Apollo experience report: Crew station integration. Volume 2: Crew station displays and controls
NASA Technical Reports Server (NTRS)
Langdoc, W. A.; Nassman, D. A.
1975-01-01
The functional requirements for the Apollo displays and controls system are presented. The configuration of the displays, controls, and panels for both the command module and the lunar module are described, and the design development and operational experience of the displays and controls system are discussed. Pertinent recommendations for future displays and controls system design efforts are made.
Meinhardt, J P; Ashton, B A; Annich, G M; Quintel, M; Hirschl, R B
2003-05-30
To evaluate the influence of pump system and flow pattern on expiratory airway collapse (EAC) in total perfluorocarbon ventilation. - Prospective, controlled, randomized animal trial for determination of (1) post-mortem changes by repeated expiration procedures (EP) with a constant flow piston pump (PP) before and after sacrifice (n = 8 rabbits), (2) differences between pump systems by subjecting animals to both PP and roller pump (RP) circuits for expiration (n = 16 rabbits). EP were performed using a servo-controlled shut-off at airway pressures < 25 cm H subset 2O randomly with either pump at different flows. - Expired volumes before and after sacrifice were not significantly different. PP and RP revealed identical mean flows, while significantly more liquid was drained using PP (p<0.05). Increasing differences towards higher flow rates indicated profound flow pulsatility in RP. - (1) post-mortem changes in expired volumes are not significant, (2) EAC is related to flow rate and pump system; (3) relationship between expiratory flow rate and drainable liquid volume is linear inverse; (4) PP provides higher drainage than RP. - Expiratory airway collapse is related to flow rate and pump system, post mortem changes in expirable volumes are not significant. Relationship between expiratory flow rate and drainable liquid volume is linear inverse, piston pump expiration provides higher drainage volumes than roller pump expiration.
NASA Technical Reports Server (NTRS)
1974-01-01
The design and development of the Skylab Orbital Workshop are discussed. The subjects considered are: (1) thrust attitude control system, (2) solar array system, (3) electrical power distribution system, (4) communication and data acquisition system, (5) illumination system, and (6) caution and warning system.
Testing and Evaluating C3I Systems That Employ AI. Volume 1. Handbook for Testing Expert Systems
1991-01-31
Designs ....... ............. .. 6-29 Nonequivalent Control Group Design ...does not receive the system; and (c) nonequivalent (and nonrandomized) control group designs that rely on statistical techniques like analysis of...implementation); (b) multiple time-series designs using a control group ; and (c) nonequivalent control group designs that obtain pretest and
Direct discretization of planar div-curl problems
NASA Technical Reports Server (NTRS)
Nicolaides, R. A.
1989-01-01
A control volume method is proposed for planar div-curl systems. The method is independent of potential and least squares formulations, and works directly with the div-curl system. The novelty of the technique lies in its use of a single local vector field component and two control volumes rather than the other way around. A discrete vector field theory comes quite naturally from this idea and is developed. Error estimates are proved for the method, and other ramifications investigated.
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... storm; (2) A run-off control system from the active portion of the landfill to collect and control at least the water volume resulting from a 24-hour, 25-year storm. (b) Run-off from the active portion of...
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... storm; (2) A run-off control system from the active portion of the landfill to collect and control at least the water volume resulting from a 24-hour, 25-year storm. (b) Run-off from the active portion of...
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... storm; (2) A run-off control system from the active portion of the landfill to collect and control at least the water volume resulting from a 24-hour, 25-year storm. (b) Run-off from the active portion of...
Investigating parameters participating in the infant respiratory control system attractor.
Terrill, Philip I; Wilson, Stephen J; Suresh, Sadasivam; Cooper, David M; Dakin, Carolyn
2008-01-01
Theoretically, any participating parameter in a non-linear system represents the dynamics of the whole system. Taken's time delay embedding theory provides the fundamental basis for allowing non-linear analysis to be performed on physiological, time-series data. In practice, only one measurable parameter is required to be measured to convey an accurate representation of the system dynamics. In this paper, the infant respiratory control system is represented using three variables-a digitally sampled respiratory inductive plethysmography waveform, and the derived parameters tidal volume and inter-breath interval time series data. For 14 healthy infants, these data streams were analysed using recurrence plot analysis across one night of sleep. The measured attractor size of these variables followed the same qualitative trends across the nights study. Results suggest that the attractor size measures of the derived IBI and tidal volume are representative surrogates for the raw respiratory waveform. The extent to which the relative attractor sizes of IBI and tidal volume remain constant through changing sleep state could potentially be used to quantify pathology, or maturation of breathing control.
Multi-processing control system for the SEL 840MP (MPCS/1) users guide. Volume 2: Operations guide
NASA Technical Reports Server (NTRS)
1972-01-01
The generation and operational use of the SEL 840MP multiprocessing control system (MPCS) are considered. System initialization, job task table generation, the MPCS command language, display library generation, and system error summary are reviewed.
Satellite Power Systems (SPS) concept definition study. Volume 4: SPS point design definition
NASA Technical Reports Server (NTRS)
Hanley, G.
1978-01-01
The satellite power systems point design concept is described. The concept definition includes satellite, ground and space systems, and their relationships. Emphasis is placed on the definition of the GaAlAs photovoltaic satellite system. The major subsystems of the satellite system including power conversion, power distribution and control, microwave, attitude control and stationkeeping, thermal control, structures, and information management and control are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, T; Kang, S; Kim, D
Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure levelmore » of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.« less
The RAAF Logistics Study. Volume 4,
1986-10-01
Use of Issue-Based Root Definitions Application of Soft Systems Methodology to 27 Information Systems Analysis Conclusion 30 LIST OF ABBREVIATIONS 58 k...Management Control Systems’, Journal of Applied Systems Analysis, Volume 6, 1979, pages 51 to 67. 5. The soft systems methodology was developed to tackle...the soft systems methodology has many advantages whi-h recmmenrl it to this type of study area, it does not mcklel the timo ev, lut i, n :-f a system
Analysis of Radio Frequency Surveillance Systems for Air Traffic Control : Volume 1. Text.
DOT National Transportation Integrated Search
1976-02-01
Performance criteria that afford quantitative evaluation of a variety of current and proposed configurations of the Air Traffic Control Radar Beacon System (ATCRBS) are described in detail. Two analytic system models are developed to allow applicatio...
DOT National Transportation Integrated Search
1996-08-01
KEYWORDS: : TRAFFIC SIGNAL CONTROL/REAL-TIME ADAPTIVE CONTROL, ADVANCED TRAFFIC MANAGEMENT SYSTEMS OR ATMS : THIS DOCUMENT PRESENTS THE METHODS, ASSUMPTIONS AND PROCEDURES USED TO COLLECT THE BASELINE INFORMATION. THE DOCUMENTATION OF SYSTEMS ...
NASA Technical Reports Server (NTRS)
Landis, Kenneth H.; Glusman, Steven I.
1985-01-01
The Advanced Cockpit Controls/Advanced Flight Control System (ACC/AFCS) study was conducted by the Boeing Vertol Company as part of the Army's Advanced Digital/Optical Control System (ADOCS) program. Specifically, the ACC/AFCS investigation was aimed at developing the flight control laws for the ADOCS demonstrator aircraft which will provide satisfactory handling qualities for an attack helicopter mission. The three major elements of design considered are as follows: Pilot's integrated Side-Stick Controller (SSC) -- Number of axes controlled; force/displacement characteristics; ergonomic design. Stability and Control Augmentation System (SCAS)--Digital flight control laws for the various mission phases; SCAS mode switching logic. Pilot's Displays--For night/adverse weather conditions, the dynamics of the superimposed symbology presented to the pilot in a format similar to the Advanced Attack Helicopter (AAH) Pilot Night Vision System (PNVS) for each mission phase as a function of ACAS characteristics; display mode switching logic. Findings from the literature review and the analysis and synthesis of desired control laws are reported in Volume 2. Conclusions drawn from pilot rating data and commentary were used to formulate recommendations for the ADOCS demonstrator flight control system design. The ACC/AFCS simulation data also provide an extensive data base to aid the development of advanced flight control system design for future V/STOL aircraft.
FAA Rotorcraft Research, Engineering, and Development Bibliography 1962-1989
1990-05-01
Albert G. Delucien) (NTIS: ADA 102 521) FAA/CT-88/10 Digital Systems Validation Handbook - Volume II (R.L. McDowall, Hardy P. Curd, Lloyd N. Popish... Digital Systems in Avionics and Flight Control Applications, Handbook - Volume I, (Ellis F. Hilt, Donald Eldredge, Jeff Webb, Charles Lucius, Michael S...Structure Statistics of Helicopter GPS Navigation with the Magnavox Z-Set (Robert D. Till) FAA/CT-82/115 Handbook - Volume I, Validation of Digital
Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 5
NASA Technical Reports Server (NTRS)
Prust, Chet D.; Hartman, Dan W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 5 contains detailed analysis and superseded analysis worksheets and the NASA FMEA to IOA worksheet cross reference and recommendations.
Control apparatus for hot gas engine
Stotts, Robert E.
1986-01-01
A mean pressure power control system for a hot gas (Stirling) engine utilizing a plurality of supply tanks for storing a working gas at different pressures. During pump down operations gas is bled from the engine by a compressor having a plurality of independent pumping volumes. In one embodiment of the invention, a bypass control valve system allows one or more of the compressor volumes to be connected to the storage tanks. By selectively sequencing the bypass valves, a capacity range can be developed over the compressor that allows for lower engine idle pressures and more rapid pump down rates.
Program Manual for Producing Weight Scaling Conversion Tables
Gary L. Tyre; Clyde A. Fasick; Frank M. Riley; Frank O. Lege
1973-01-01
Three computer programs are presented which can be applied by individual firms to establish a weight-scaling information system, The first generates volume estimates from truckload weights for any combination of veneer, sawmill, and pulpwood volumes. The second provides quality-control information by tabulating differences between estimated volumes and observed check-...
Development of ADOCS controllers and control laws. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Landis, Kenneth H.; Glusman, Steven I.
1985-01-01
The Advanced Cockpit Controls/Advanced Flight Control System (ACC/AFCS) study was conducted by the Boeing Vertol Company as part of the Army's Advanced Digital/Optical Control System (ADOCS) program. Specifically, the ACC/AFCS investigation was aimed at developing the flight control laws for the ADOCS demonstrator aircraft that will provide satisfactory handling qualities for an attack helicopter mission. The three major elements of design considered during the study are as follows: Pilot's integrated Side-Stick Controller (SSC) -- Number of axes controlled; force/displacement characteristics; ergonomic design. Stability and Control Augmentation System (SCAS)--Digital flight control laws for the various mission phases; SCAS mode switching logic. Pilot's Displays--For night/adverse weather conditions, the dynamics of the superimposed symbology presented to the pilot in a format similar to the Advanced Attack Helicopter (AAH) Pilot Night Vision System (PNVS) for each mission phase as a function of SCAS characteristics; display mode switching logic. Volume 1 is an Executive Summary of the study. Conclusions drawn from analysis of pilot rating data and commentary were used to formulate recommendations for the ADOCS demonstrator flight control system design. The ACC/AFCS simulation data also provide an extensive data base to aid the development of advanced flight control system design for future V/STOL aircraft.
Optimal strategy analysis based on robust predictive control for inventory system with random demand
NASA Astrophysics Data System (ADS)
Saputra, Aditya; Widowati, Sutrisno
2017-12-01
In this paper, the optimal strategy for a single product single supplier inventory system with random demand is analyzed by using robust predictive control with additive random parameter. We formulate the dynamical system of this system as a linear state space with additive random parameter. To determine and analyze the optimal strategy for the given inventory system, we use robust predictive control approach which gives the optimal strategy i.e. the optimal product volume that should be purchased from the supplier for each time period so that the expected cost is minimal. A numerical simulation is performed with some generated random inventory data. We simulate in MATLAB software where the inventory level must be controlled as close as possible to a set point decided by us. From the results, robust predictive control model provides the optimal strategy i.e. the optimal product volume that should be purchased and the inventory level was followed the given set point.
Flight control systems properties and problems. Volume 2: Block diagram compendium
NASA Technical Reports Server (NTRS)
Johnston, D. E.
1975-01-01
A compendium of stability augmentation system and autopilot block diagrams is presented. Descriptive materials for 48 different types of aircraft systems are provided. A broad representation of the many mechanical approaches which have been used for aircraft control is developed.
An analysis of radio frequency surveillance systems for air traffic control volume II: appendixes
DOT National Transportation Integrated Search
1976-02-01
Performance criteria that afford quantitative evaluation of a variety of current and proposed configurations of the Air Traffic Control Radar Beacon System (ATCRBS) are described in detail. Two analytic system models are developed to allow applicatio...
Treit, Sarah; Zhou, Dongming; Chudley, Albert E.; Andrew, Gail; Rasmussen, Carmen; Nikkel, Sarah M.; Samdup, Dawa; Hanlon-Dearman, Ana; Loock, Christine; Beaulieu, Christian
2016-01-01
Head circumference is used together with other measures as a proxy for central nervous system damage in the diagnosis of fetal alcohol spectrum disorders, yet the relationship between head circumference and brain volume has not been investigated in this population. The objective of this study is to characterize the relationship between head circumference, brain volume and cognitive performance in a large sample of children with prenatal alcohol exposure (n = 144) and healthy controls (n = 145), aged 5–19 years. All participants underwent magnetic resonance imaging to yield brain volumes and head circumference, normalized to control for age and sex. Mean head circumference, brain volume, and cognitive scores were significantly reduced in the prenatal alcohol exposure group relative to controls, albeit with considerable overlap between groups. Males with prenatal alcohol exposure had reductions in all three measures, whereas females with prenatal alcohol exposure had reduced brain volumes and cognitive scores, but no difference in head circumference relative to controls. Microcephaly (defined here as head circumference ≤ 3rd percentile) occurred more often in prenatal alcohol exposed participants than controls, but 90% of the exposed sample had head circumferences above this clinical cutoff indicating that head circumference is not a sensitive marker of prenatal alcohol exposure. Normalized head circumference and brain volume were positively correlated in both groups, and subjects with very low head circumference typically had below-average brain volumes. Conversely, over half of the subjects with very low brain volumes had normal head circumferences, which may stem from differential effects of alcohol on the skeletal and nervous systems. There were no significant correlations between head circumference and any cognitive score. These findings confirm group-level reductions in head circumference and increased rates of microcephaly in children with prenatal alcohol exposure, but raise concerns about the predictive value of this metric at an individual-subject level. PMID:26928125
Treit, Sarah; Zhou, Dongming; Chudley, Albert E; Andrew, Gail; Rasmussen, Carmen; Nikkel, Sarah M; Samdup, Dawa; Hanlon-Dearman, Ana; Loock, Christine; Beaulieu, Christian
2016-01-01
Head circumference is used together with other measures as a proxy for central nervous system damage in the diagnosis of fetal alcohol spectrum disorders, yet the relationship between head circumference and brain volume has not been investigated in this population. The objective of this study is to characterize the relationship between head circumference, brain volume and cognitive performance in a large sample of children with prenatal alcohol exposure (n = 144) and healthy controls (n = 145), aged 5-19 years. All participants underwent magnetic resonance imaging to yield brain volumes and head circumference, normalized to control for age and sex. Mean head circumference, brain volume, and cognitive scores were significantly reduced in the prenatal alcohol exposure group relative to controls, albeit with considerable overlap between groups. Males with prenatal alcohol exposure had reductions in all three measures, whereas females with prenatal alcohol exposure had reduced brain volumes and cognitive scores, but no difference in head circumference relative to controls. Microcephaly (defined here as head circumference ≤ 3rd percentile) occurred more often in prenatal alcohol exposed participants than controls, but 90% of the exposed sample had head circumferences above this clinical cutoff indicating that head circumference is not a sensitive marker of prenatal alcohol exposure. Normalized head circumference and brain volume were positively correlated in both groups, and subjects with very low head circumference typically had below-average brain volumes. Conversely, over half of the subjects with very low brain volumes had normal head circumferences, which may stem from differential effects of alcohol on the skeletal and nervous systems. There were no significant correlations between head circumference and any cognitive score. These findings confirm group-level reductions in head circumference and increased rates of microcephaly in children with prenatal alcohol exposure, but raise concerns about the predictive value of this metric at an individual-subject level.
Space vehicle electrical power processing distribution and control study. Volume 1: Summary
NASA Technical Reports Server (NTRS)
Krausz, A.
1972-01-01
A concept for the processing, distribution, and control of electric power for manned space vehicles and future aircraft is presented. Emphasis is placed on the requirements of the space station and space shuttle configurations. The systems involved are referred to as the processing distribution and control system (PDCS), electrical power system (EPS), and electric power generation system (EPGS).
DOT National Transportation Integrated Search
2009-05-01
In an effort to control reflective cracking in hot-mix asphalt (HMA) overlays placed over Portland Cement : Concrete (PCC) pavements, several reflective crack control (RCC) systems, including interlayer systems, : have been used. However, the cost-ef...
DOT National Transportation Integrated Search
1975-04-01
The report describes a computer simulation of the Air Traffic Control Radar Beacon System (ATCRBS). Operating on real air traffic data and actual characteristics of the relevant ground interrogators, the FORTRAN program re-enacts system operation in ...
Large space telescope, phase A. Volume 5: Support systems module
NASA Technical Reports Server (NTRS)
1972-01-01
The development and characteristics of the support systems module for the Large Space Telescope are discussed. The following systems and described: (1) thermal control, (2) electrical, (3) communication and data landing, (4) attitude control system, and (5) structural features. Analyses of maintainability and reliability considerations are included.
DOT National Transportation Integrated Search
1975-04-01
The report describes a computer simulation of the Air Traffic Control Radar Beacon System (ATCRBS). Operating on real air traffic data and actual characteristics of the relevant ground interrogators, the FORTRAN program re-enacts system operation in ...
NASA Technical Reports Server (NTRS)
Agnew, Donald L.; Jones, Peter A.
1989-01-01
A study was conducted to define reasonable and representative large deployable reflector (LDR) system concepts for the purpose of defining a technology development program aimed at providing the requisite technological capability necessary to start LDR development by the end of 1991. This volume includes the executive summary for the total study, a report of thirteen system analysis and trades tasks (optical configuration, aperture size, reflector material, segmented mirror, optical subsystem, thermal, pointing and control, transportation to orbit, structures, contamination control, orbital parameters, orbital environment, and spacecraft functions), and descriptions of three selected LDR system concepts. Supporting information is contained in appendices.
NASA Technical Reports Server (NTRS)
Hanks, G. W.; Shomber, H. A.; Dethman, H. A.; Gratzer, L. B.; Maeshiro, A.; Gangsaas, D.; Blight, J. D.; Buchan, S. M.; Crumb, C. B.; Dorwart, R. J.
1981-01-01
The current status of the Active Controls Technology (ACT) for the advanced subsonic transport project is investigated through analysis of the systems technical data. Control systems technologies under examination include computerized reliability analysis, pitch axis fly by wire actuator, flaperon actuation system design trade study, control law synthesis and analysis, flutter mode control and gust load alleviation analysis, and implementation of alternative ACT systems. Extensive analysis of the computer techniques involved in each system is included.
High salt intake reprioritizes osmolyte and energy metabolism for body fluid conservation.
Kitada, Kento; Daub, Steffen; Zhang, Yahua; Klein, Janet D; Nakano, Daisuke; Pedchenko, Tetyana; Lantier, Louise; LaRocque, Lauren M; Marton, Adriana; Neubert, Patrick; Schröder, Agnes; Rakova, Natalia; Jantsch, Jonathan; Dikalova, Anna E; Dikalov, Sergey I; Harrison, David G; Müller, Dominik N; Nishiyama, Akira; Rauh, Manfred; Harris, Raymond C; Luft, Friedrich C; Wassermann, David H; Sands, Jeff M; Titze, Jens
2017-05-01
Natriuretic regulation of extracellular fluid volume homeostasis includes suppression of the renin-angiotensin-aldosterone system, pressure natriuresis, and reduced renal nerve activity, actions that concomitantly increase urinary Na+ excretion and lead to increased urine volume. The resulting natriuresis-driven diuretic water loss is assumed to control the extracellular volume. Here, we have demonstrated that urine concentration, and therefore regulation of water conservation, is an important control system for urine formation and extracellular volume homeostasis in mice and humans across various levels of salt intake. We observed that the renal concentration mechanism couples natriuresis with correspondent renal water reabsorption, limits natriuretic osmotic diuresis, and results in concurrent extracellular volume conservation and concentration of salt excreted into urine. This water-conserving mechanism of dietary salt excretion relies on urea transporter-driven urea recycling by the kidneys and on urea production by liver and skeletal muscle. The energy-intense nature of hepatic and extrahepatic urea osmolyte production for renal water conservation requires reprioritization of energy and substrate metabolism in liver and skeletal muscle, resulting in hepatic ketogenesis and glucocorticoid-driven muscle catabolism, which are prevented by increasing food intake. This natriuretic-ureotelic, water-conserving principle relies on metabolism-driven extracellular volume control and is regulated by concerted liver, muscle, and renal actions.
High salt intake reprioritizes osmolyte and energy metabolism for body fluid conservation
Kitada, Kento; Daub, Steffen; Zhang, Yahua; Klein, Janet D.; Nakano, Daisuke; Pedchenko, Tetyana; Lantier, Louise; LaRocque, Lauren M.; Marton, Adriana; Neubert, Patrick; Schröder, Agnes; Rakova, Natalia; Jantsch, Jonathan; Dikalova, Anna E.; Dikalov, Sergey I.; Harrison, David G.; Müller, Dominik N.; Nishiyama, Akira; Rauh, Manfred; Harris, Raymond C.; Luft, Friedrich C.; Wasserman, David H.; Sands, Jeff M.
2017-01-01
Natriuretic regulation of extracellular fluid volume homeostasis includes suppression of the renin-angiotensin-aldosterone system, pressure natriuresis, and reduced renal nerve activity, actions that concomitantly increase urinary Na+ excretion and lead to increased urine volume. The resulting natriuresis-driven diuretic water loss is assumed to control the extracellular volume. Here, we have demonstrated that urine concentration, and therefore regulation of water conservation, is an important control system for urine formation and extracellular volume homeostasis in mice and humans across various levels of salt intake. We observed that the renal concentration mechanism couples natriuresis with correspondent renal water reabsorption, limits natriuretic osmotic diuresis, and results in concurrent extracellular volume conservation and concentration of salt excreted into urine. This water-conserving mechanism of dietary salt excretion relies on urea transporter–driven urea recycling by the kidneys and on urea production by liver and skeletal muscle. The energy-intense nature of hepatic and extrahepatic urea osmolyte production for renal water conservation requires reprioritization of energy and substrate metabolism in liver and skeletal muscle, resulting in hepatic ketogenesis and glucocorticoid-driven muscle catabolism, which are prevented by increasing food intake. This natriuretic-ureotelic, water-conserving principle relies on metabolism-driven extracellular volume control and is regulated by concerted liver, muscle, and renal actions. PMID:28414295
An integrated compact airborne multispectral imaging system using embedded computer
NASA Astrophysics Data System (ADS)
Zhang, Yuedong; Wang, Li; Zhang, Xuguo
2015-08-01
An integrated compact airborne multispectral imaging system using embedded computer based control system was developed for small aircraft multispectral imaging application. The multispectral imaging system integrates CMOS camera, filter wheel with eight filters, two-axis stabilized platform, miniature POS (position and orientation system) and embedded computer. The embedded computer has excellent universality and expansibility, and has advantages in volume and weight for airborne platform, so it can meet the requirements of control system of the integrated airborne multispectral imaging system. The embedded computer controls the camera parameters setting, filter wheel and stabilized platform working, image and POS data acquisition, and stores the image and data. The airborne multispectral imaging system can connect peripheral device use the ports of the embedded computer, so the system operation and the stored image data management are easy. This airborne multispectral imaging system has advantages of small volume, multi-function, and good expansibility. The imaging experiment results show that this system has potential for multispectral remote sensing in applications such as resource investigation and environmental monitoring.
Effects of VR system fidelity on analyzing isosurface visualization of volume datasets.
Laha, Bireswar; Bowman, Doug A; Socha, John J
2014-04-01
Volume visualization is an important technique for analyzing datasets from a variety of different scientific domains. Volume data analysis is inherently difficult because volumes are three-dimensional, dense, and unfamiliar, requiring scientists to precisely control the viewpoint and to make precise spatial judgments. Researchers have proposed that more immersive (higher fidelity) VR systems might improve task performance with volume datasets, and significant results tied to different components of display fidelity have been reported. However, more information is needed to generalize these results to different task types, domains, and rendering styles. We visualized isosurfaces extracted from synchrotron microscopic computed tomography (SR-μCT) scans of beetles, in a CAVE-like display. We ran a controlled experiment evaluating the effects of three components of system fidelity (field of regard, stereoscopy, and head tracking) on a variety of abstract task categories that are applicable to various scientific domains, and also compared our results with those from our prior experiment using 3D texture-based rendering. We report many significant findings. For example, for search and spatial judgment tasks with isosurface visualization, a stereoscopic display provides better performance, but for tasks with 3D texture-based rendering, displays with higher field of regard were more effective, independent of the levels of the other display components. We also found that systems with high field of regard and head tracking improve performance in spatial judgment tasks. Our results extend existing knowledge and produce new guidelines for designing VR systems to improve the effectiveness of volume data analysis.
NASA Technical Reports Server (NTRS)
1973-01-01
The objectives, functions, and organization of the Deep Space Network are summarized. The Deep Space Instrumentation Facility, the Ground Communications Facility, and the Network Control System are described.
A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.
Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H
2000-01-01
Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.
Thosar, Archana; Patra, Amit; Bhattacharyya, Souvik
2008-07-01
Design of a nonlinear control system for a Variable Air Volume Air Conditioning (VAVAC) plant through feedback linearization is presented in this article. VAVAC systems attempt to reduce building energy consumption while maintaining the primary role of air conditioning. The temperature of the space is maintained at a constant level by establishing a balance between the cooling load generated in the space and the air supply delivered to meet the load. The dynamic model of a VAVAC plant is derived and formulated as a MIMO bilinear system. Feedback linearization is applied for decoupling and linearization of the nonlinear model. Simulation results for a laboratory scale plant are presented to demonstrate the potential of keeping comfort and maintaining energy optimal performance by this methodology. Results obtained with a conventional PI controller and a feedback linearizing controller are compared and the superiority of the proposed approach is clearly established.
System for detecting operating errors in a variable valve timing engine using pressure sensors
Wiles, Matthew A.; Marriot, Craig D
2013-07-02
A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.
Cerebral control of the bladder in normal and urge-incontinent women
Griffiths, Derek; Tadic, Stasa D.; Schaefer, Werner; Resnick, Neil M.
2007-01-01
Aim: To identify age-related changes in the normal brain/bladder control system, and differences between urge incontinence in younger and older women, as shown by brain responses to bladder filling; and to use age, bladder volume, urge incontinence and detrusor overactivity (DO) as probes to reveal control-system function. Functional MRI was used to examine regional brain responses to bladder infusion in 21 females (26 – 85 years): 11 “cases” with urge incontinence and DO (proven previously) and 10 normal “controls”. Responses and their age dependence were determined at small and large bladder volumes, in whole brain and in regions of interest representing right insula and anterior cingulate (ACG). In “controls”, increasing bladder volume/sensation led to increasing insular responses; with increasing age, insular responses became weaker. In younger “cases”, ACG responded abnormally strongly at large bladder volumes/strong sensation. Elderly “cases” showed strong ACG responses even at small bladder volume, but more moderate responses at larger volumes; if DO occurred, pontine micturition center (PMC) activation did not increase. Conclusion: Among normal “controls”, increasing age leads to decreased responses in brain regions involved in bladder control, including right insula, consistent with its role in mapping normal bladder sensations. Strong ACG activation occurs in urge-incontinent “cases” and may be a sign of urgency, indicating recruitment of alternative pathways when loss of bladder control is feared. Easier ACG provocation in older “cases” reflects lack of physiological reserve or different etiology. ACG responses seem associated with PMC inhibition: reduced ACG activity accompanies failure of inhibition (DO). PMID:17574871
Wisconsin Elementary Teacher Education Project. Volumes I-IV.
ERIC Educational Resources Information Center
Kean, John M., Ed.
This four-volume report includes position papers and specifications for the elementary teacher education program of the University of Wisconsin in the year 1975 and beyond. Volume 1 includes a series of 12 position papers which cover topics ranging from teacher roles and systems approaches to instruction to control and management procedures for…
NASA Astrophysics Data System (ADS)
Cheng, Xiaolong; Liu, Jinxiang; Wang, Yu; Yuan, Xiaolei; Jin, Hui
2018-05-01
The fresh air volume in Temperature and Humidity Independent Control of Air-conditioning System(THIC) of a typical office was comfirmed, under the premise of adopting the refrigeration dehumidifying fresh air unit(7°C/12°C). By detailed calculating the space moisture load and the fresh air volume required for dehumidification in 120 selected major cities in China, it can be inferred that the minimum fresh air volume required for dehumidification in THIC is mainly determined by the local outdoor air moisture and the outdoor wind speed; Then the mathematical fitting software Matlab was used to fit the three parameters, and a simplified formula for calculating the minimum per capita fresh air volume required for dehumidification was obtained; And the indoor relative humidity was simulated by the numerical software Airpak and the results by using the formula data and the data for hygiene were compared to verify the relibility of the simplified formula.
A Second Law Based Unstructured Finite Volume Procedure for Generalized Flow Simulation
NASA Technical Reports Server (NTRS)
Majumdar, Alok
1998-01-01
An unstructured finite volume procedure has been developed for steady and transient thermo-fluid dynamic analysis of fluid systems and components. The procedure is applicable for a flow network consisting of pipes and various fittings where flow is assumed to be one dimensional. It can also be used to simulate flow in a component by modeling a multi-dimensional flow using the same numerical scheme. The flow domain is discretized into a number of interconnected control volumes located arbitrarily in space. The conservation equations for each control volume account for the transport of mass, momentum and entropy from the neighboring control volumes. In addition, they also include the sources of each conserved variable and time dependent terms. The source term of entropy equation contains entropy generation due to heat transfer and fluid friction. Thermodynamic properties are computed from the equation of state of a real fluid. The system of equations is solved by a hybrid numerical method which is a combination of simultaneous Newton-Raphson and successive substitution schemes. The paper also describes the application and verification of the procedure by comparing its predictions with the analytical and numerical solution of several benchmark problems.
Moving Stormwater Infrastructure from Real-time Control to Smart Systems
NASA Astrophysics Data System (ADS)
Wadzuk, B.; Bryant, S.; Lewellyn, C.; Zaremba, G.; Traver, R.
2017-12-01
Urban areas, especially combined sewer communities, are using green infrastructure (GI) systems (e.g. rain gardens, green roofs) to mitigate stormwater runoff volume, rate, and quality issues. Most municipal guidance and regulation limits these systems to static, passive designs that neither fully utilize the active hydrology of a GI system during and after a rainfall event, nor enable dynamic operational control. Real-time control (RTC) applied to GI is emerging, and under ideal model conditions has shown improved performance (i.e., greater volumes managed while minimizing downstream impact). There are a few RTC pilot field projects with promising results, such as on a cistern - green roof system there were only 30 overflow events out of 126 rain events and at a rain garden - cistern system only 1 of 81 events resulted in overflow. However, RTC does not get to a fully dynamic system as the initiation and consequent action is preset and static. In stormwater RTC systems, the initiation is typically a rain forecast or a sensor reading. At a rain garden - cistern system, a cistern that fills when raining is hard set to pump water to the rain garden 24 hours after the predicted rain ends. There have been instances where there is rain occurring or only a minimal amount of dry time for the rain garden to reestablish capacity for the pumped stored water. There is also no mechanism to automatically change the pump initiation time based on season or ambient conditions. A cistern - green roof system that uses stored water in an upstream cistern for green roof irrigation is initiated on a set soil moisture reading or a set irrigation volume daily. The soil moisture reading was rarely reached, so irrigation was often not initiated and the set daily irrigation volume did not vary over season. Moving from RTC to a smart system uses longer term and/or historical data to inform decisions beyond what a short-term forecast or real-time sensor can provide to give more context and flexibility in the initiation - consequent action logic. The use of the Standardized Precipitation Evapotranspiration Index as a back-cast and forecast tool to calculate an appropriate irrigation volume based on what rainfall is pending and whether the system is in drought state is used and discussed to move the GI systems into smart control.
Demand-type gas supply system for rocket borne thin-window proportional counters
NASA Technical Reports Server (NTRS)
Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.
1977-01-01
A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.
Aerospace Vehicle Design, Spacecraft Section. Volume 3
NASA Technical Reports Server (NTRS)
1988-01-01
Research results are presented for the following groups: Project Mars Airplane Vehicle and Reconnaissance Instrument Carrier (MAVRIC), ACME, ARES, Project ACRONYM, Mars Aircraft Recepticle with Technical Instruments, Aerobraking, and Navigation (MARTIAN), and NOMADS. Each project is described by the following areas of focus: mission planning and costs; aerobraking systems; structures and thermal control systems; attitude and articulation control systems; comman and data control systems; science instrumentation; and power and propulsion systems.
Annual Review of Research under the Joint Services Electronics Program. Volume 1.
1982-12-01
time varying nonlinear system be transformable to a controllable time -invariant linear system have been presented. * If a...Conference Papers and Abstracts 1. Hunt, L.R., and R. Su, " Control of Nonlinear Time -Varying Systems ," 20th IEEE Conf. on Decision and Control , pp. 558...being C= vector fields on I,. We give necessary and sufficient conditions for this system to be transformable to a time -invariant controllable
Defining Human-Centered System Issues for Verifying and Validating Air Traffic Control Systems
DOT National Transportation Integrated Search
1993-01-01
Over the past 40 years, the application of automation to the U.S. air traffic : control (ATC) system has grown enormously to meet significant increases in air : traffic volume. The next ten years will witness a dramatic overhaul of computer : hardwar...
Shigemi, Kenji
2016-05-01
To maintain proper cardiac preload is one of the most effective procedures for the systemic circulation remaining stable. In particular, the balance between vascular capacity and total blood volume must be maintained within appropriate range by the administration of fluids, blood and/or vasoactive drugs with mean circulatory filling pressure (Pmcf), central venous pressure (CVP) or stroke volume variation (SVV). End-diastolic left ventricular volume (Ved) is theoretically the best index of cardiac preload; however, without transesophageal echocardbalanceiogram we cannot directly monitor Ved during anesthesia. The infused fluid volume remaining in intravascular space, the vascular capacity controlled by autonomic nervous system and/or vasoactive agents, and the unstressed blood volume properly mobilized to excess blood volume are the crucial factors to maintain cardiac output The knowledge of vascular physiology contribute the decision making to manipulate such factors to control blood circulation during general anesthesia. For example, CVP is usually maintained in the narrow range and seems to be stable; however, it must be changed just after the circulatory disturbances, such as acute bleeding, blood transfusion, and fluid infusion, and followed by gradual returning to initial value, because of the solid mechanism to preserve cardiac output
YF-12 cooperative airframe/propulsion control system program, volume 1
NASA Technical Reports Server (NTRS)
Anderson, D. L.; Connolly, G. F.; Mauro, F. M.; Reukauf, P. J.; Marks, R. (Editor)
1980-01-01
Several YF-12C airplane analog control systems were converted to a digital system. Included were the air data computer, autopilot, inlet control system, and autothrottle systems. This conversion was performed to allow assessment of digital technology applications to supersonic cruise aircraft. The digital system was composed of a digital computer and specialized interface unit. A large scale mathematical simulation of the airplane was used for integration testing and software checkout.
Evaluation of the intelligent cruise control system. Volume 2, Appendices
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was sponsored by the National Highway Traffic Safety Administration (NHTSA) and based on an ICC Field Operational Test (FOT) conducted under a cooperative agreement between the NHTSA and the Univ...
DOT National Transportation Integrated Search
1995-08-01
KEYWORDS : RESEARCH AND DEVELOPMENT OR R&D, CRASH REDUCTION, FATALITIES REDUCTION, LATERAL GUIDANCE, LONGITUDINAL GUIDANCE, ADVANCED VEHICLE CONTROL & SAFETY SYSTEMS OR AVCSS, ADVANCED VEHICLE CONTROL SYSTEM OR AVCS, INTELLIGENT VEHICLE INITIATIV...
40 CFR 86.1868-12 - CO2 credits for improving the efficiency of air conditioning systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., engine displacement, transmission class and configuration, interior volume, climate control system type... Creditvalue (g/mi) Reduced reheat, with externally-controlled, variable-displacement compressor (e.g. a compressor that controls displacement based on temperature setpoint and/or cooling demand of the air...
40 CFR 1060.525 - How do I test fuel systems for diurnal emissions?
Code of Federal Regulations, 2010 CFR
2010-07-01
... fuel tanks, and volume-compensating air bags. (b) You may subtract your fuel tank's permeation...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... diurnal emission standard. (8) For emission control technologies that rely on a sealed fuel system, you...
40 CFR 1060.525 - How do I test fuel systems for diurnal emissions?
Code of Federal Regulations, 2011 CFR
2011-07-01
... fuel tanks, and volume-compensating air bags. (b) You may subtract your fuel tank's permeation...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... diurnal emission standard. (8) For emission control technologies that rely on a sealed fuel system, you...
DOT National Transportation Integrated Search
1972-03-24
This report summarizes the need for an Integrated Marine Traffic Informaiton and Control System (IMTIC) in the St. Lawrence Seaway. The analytic emphasis is on the Welland Canal to Gulf of St. Lawrence portion of the Seaway system. The Upper Great La...
Tokamak experimental power reactor conceptual design. Volume II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1976-08-01
Volume II contains the following appendices: (1) summary of EPR design parameters, (2) impurity control, (3) plasma computational models, (4) structural support system, (5) materials considerations for the primary energy conversion system, (6) magnetics, (7) neutronics penetration analysis, (8) first wall stress analysis, (9) enrichment of isotopes of hydrogen by cryogenic distillation, and (10) noncircular plasma considerations. (MOW)
Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.
Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi
2011-01-01
Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 2
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. There are four volumes. This volume contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the second book of volume four. Some of the items it contains are specs for the emergency shutdown panel, specs for the simulator software, simulator hardware specs, site operator terminal requirements, control data system requirements, software project management plan, elastomeric teeter bearing requirement specs, specs for the controls electronic cabinet, and specs for bolt pretensioning.
NASA Technical Reports Server (NTRS)
Notti, J. E.; Cormack, A., III; Schmill, W. C.
1974-01-01
An Integrated Power/Attitude Control System (IPACS) concept consisting of an array of spinning flywheels, with or without gimbals, capable of performing the dual function of power storage and generation, as well as attitude control has been investigated. This system provides attitude control through momentum storage, and replaces the storage batteries onboard the spacecraft. The results of the investigation are presented in two volumes. The trade-off studies performed to establish the feasibility, cost effectiveness, required level of development, and boundaries of application of IPACS to a wide variety of spacecraft are discussed. The conceptual designs for a free-flying research application module (RAM), and for a tracking and data relay satellite (TDRS) are presented. Results from dynamic analyses and simulations of the IPACS conceptual designs are included.
[Compatible biomass models of natural spruce (Picea asperata)].
Wang, Jin Chi; Deng, Hua Feng; Huang, Guo Sheng; Wang, Xue Jun; Zhang, Lu
2017-10-01
By using nonlinear measurement error method, the compatible tree volume and above ground biomass equations were established based on the volume and biomass data of 150 sampling trees of natural spruce (Picea asperata). Two approaches, controlling directly under total aboveground biomass and controlling jointly from level to level, were used to design the compatible system for the total aboveground biomass and the biomass of four components (stem, bark, branch and foliage), and the total ground biomass could be estimated independently or estimated simultaneously in the system. The results showed that the R 2 of the one variable and bivariate compatible tree volume and aboveground biomass equations were all above 0.85, and the maximum value reached 0.99. The prediction effect of the volume equations could be improved significantly when tree height was included as predictor, while it was not significant in biomass estimation. For the compatible biomass systems, the one variable model based on controlling jointly from level to level was better than the model using controlling directly under total above ground biomass, but the bivariate models of the two methods were similar. Comparing the imitative effects of the one variable and bivariate compatible biomass models, the results showed that the increase of explainable variables could significantly improve the fitness of branch and foliage biomass, but had little effect on other components. Besides, there was almost no difference between the two methods of estimation based on the comparison.
Control of volume resistivity in inorganic-organic separators. [for alkaline batteries
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Manzo, M. A.
1980-01-01
Control of resistivity in NASA inorganic-organic separators is achieved by incorporating small percentages of high surface area, fine-particle silica with other ingredients in the separator coating. The volume resistivity appears to be predictable from coating composition, that is, from the surface area of filler particles in the coating. The approach has been applied to two polymer-'plasticizer'-filler coating systems, where the filler content of each is below the generally acknowledged critical pigment volume concentration of the coating. Application of these coating systems to 0.0254 cm thick (10 mil) fuel-cell grade asbestos sheet produces inexpensive, flexible, microporous separators that perform at least as well as the original inorganic-organic concept, the Astropower separator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Di; Jin, Chunlian; Balducci, Patrick J.
2013-12-01
This volume presents the battery storage evaluation tool developed at Pacific Northwest National Laboratory (PNNL), which is used to evaluate benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. This tool is based on the optimal control strategies to capture multiple services from a single energy storage device. In this control strategy, at each hour, a look-ahead optimization is first formulated and solved to determine battery base operating point. The minute by minute simulation is then performed to simulate the actual battery operation. This volume provide backgroundmore » and manual for this evaluation tool.« less
Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian
2015-02-09
A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible.
Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian
2015-01-01
A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible. PMID:25836207
NASA Technical Reports Server (NTRS)
Chie, C. M.
1980-01-01
The Solar Power Satellite (SPS) concept and the reference phase control system investigated in earlier efforts are reviewed. A summary overview of the analysis and selection of the pilot signal and power transponder design is presented along with the SOLARSIM program development and the simulated SPS phase control performance. Evaluations of the ground based phase control system as an alternate phase control concept are summarized.
Development of ADOCS controllers and control laws. Volume 3: Simulation results and recommendations
NASA Technical Reports Server (NTRS)
Landis, Kenneth H.; Glusman, Steven I.
1985-01-01
The Advanced Cockpit Controls/Advanced Flight Control System (ACC/AFCS) study was conducted by the Boeing Vertol Company as part of the Army's Advanced Digital/Optical Control System (ADOCS) program. Specifically, the ACC/AFCS investigation was aimed at developing the flight control laws for the ADOCS demonstator aircraft which will provide satisfactory handling qualities for an attack helicopter mission. The three major elements of design considered are as follows: Pilot's integrated Side-Stick Controller (SSC) -- Number of axes controlled; force/displacement characteristics; ergonomic design. Stability and Control Augmentation System (SCAS)--Digital flight control laws for the various mission phases; SCAS mode switching logic. Pilot's Displays--For night/adverse weather conditions, the dynamics of the superimposed symbology presented to the pilot in a format similar to the Advanced Attack Helicopter (AAH) Pilot Night Vision System (PNVS) for each mission phase is a function of SCAS characteristics; display mode switching logic. Results of the five piloted simulations conducted at the Boeing Vertol and NASA-Ames simulation facilities are presented in Volume 3. Conclusions drawn from analysis of pilot rating data and commentary were used to formulate recommendations for the ADOCS demonstrator flight control system design. The ACC/AFCS simulation data also provide an extensive data base to aid the development of advanced flight control system design for future V/STOL aircraft.
RoMPS concept review automatic control of space robot, volume 2
NASA Technical Reports Server (NTRS)
Dobbs, M. E.
1991-01-01
Topics related to robot operated materials processing in space (RoMPS) are presented in view graph form and include: (1) system concept; (2) Hitchhiker Interface Requirements; (3) robot axis control concepts; (4) Autonomous Experiment Management System; (5) Zymate Robot Controller; (6) Southwest SC-4 Computer; (7) oven control housekeeping data; and (8) power distribution.
DOT National Transportation Integrated Search
1988-01-01
The development of a prototype knowledge-based expert system (KBES) for selecting appropriate traffic control strategies and management techniques around highway work zones was initiated. This process was encompassed by the steps that formulate the p...
Thompson, B G
1989-03-01
Lemna minor (common duckweed) and a Wolffia sp. were grown in submerged growth systems. Submerged growth increased the productivity unit volume (P/UV) of the organisms and may allow these plants to be used in a controlled ecological life support system (CELSS).
NASA Astrophysics Data System (ADS)
Thompson, B. G.
Lemna minor (common duckweed) and a Wolffia sp. were grown in submerged growth systems. Submerged growth increased the productivity/unit volume (P/UV) of the organisms and may allow these plants to be used in a controlled ecological life support system (CELSS).
A microprocessor-controlled tracheal insufflation-assisted total liquid ventilation system.
Parker, James Courtney; Sakla, Adel; Donovan, Francis M; Beam, David; Chekuri, Annu; Al-Khatib, Mohammad; Hamm, Charles R; Eyal, Fabien G
2009-09-01
A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.
Validation of Digital Systems in Avionics and Flight Control Applications Handbook. Volume 1.
1983-07-01
will also be available to Airways Facilities, Systems Research and Development Service, Air Traffic Control Service, and Flight Standards elements...2114, March 12-14, 1979. 3. Validation Methods Research for Fault-Tolerant Avionics and Control Systems-- *r Working Group Meeting II, NASA...command generation with the multiple methods becoming avail- able for closure of the outer control loop necessitates research on alternative integration
Evaluation of the intelligent cruise control system : volume 1 : study results
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was based on an ICC Field Operational Test (FOT) performed in Michigan. The FOT involved 108 volunteers recruited to drive ten ICC-equipped Chrysler Concordes. Testing was initiated in July 1996 ...
Intelligent control system based on ARM for lithography tool
NASA Astrophysics Data System (ADS)
Chen, Changlong; Tang, Xiaoping; Hu, Song; Wang, Nan
2014-08-01
The control system of traditional lithography tool is based on PC and MCU. The PC handles the complex algorithm, human-computer interaction, and communicates with MCU via serial port; The MCU controls motors and electromagnetic valves, etc. This mode has shortcomings like big volume, high power consumption, and wasting of PC resource. In this paper, an embedded intelligent control system of lithography tool, based on ARM, is provided. The control system used S5PV210 as processor, completing the functions of PC in traditional lithography tool, and provided a good human-computer interaction by using LCD and capacitive touch screen. Using Android4.0.3 as operating system, the equipment provided a cool and easy UI which made the control more user-friendly, and implemented remote control and debug, pushing video information of product by network programming. As a result, it's convenient for equipment vendor to provide technical support for users. Finally, compared with traditional lithography tool, this design reduced the PC part, making the hardware resources efficiently used and reducing the cost and volume. Introducing embedded OS and the concepts in "The Internet of things" into the design of lithography tool can be a development trend.
Positional calibration of an ultrasound image-guided robotic breast biopsy system.
Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob
2012-03-01
Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.
[Appropriate dust control measures for jade carving operations].
Liu, Jiang; Wang, Qiushui; Liu, Guangquan
2002-12-01
To provide the appropriate dust control measures for jade carving operations. Dust concentrations in the workplace were measured according to GB/T 5748-85. Ventilation system of dust control were measured according to GB/T 16157-1996. Dust particle size distributions for different sources and particle size fraction collecting efficiencies of the dust collectors were measured with WY-1 in-stack 7 stage cascade impactors. On the basis of adopting wet process in the carving operations, local exhaust ventilation system for dust control was installed, which included: the special designed slot exhaust hoods with hood face velocity of 2.5 m/s and exhaust volume of 600 m3/h. The pipe sizes were determined according to the air volume passing through the pipe and the reasonable air velocities. Impinging scrubber or bag filter dust collector were selected to treat the dust laden air from the local exhaust ventilation system, which gave a total collecting efficiency of 97% for impinging scrubber and 98% for bag filter; The type of fan and its size were selected according to the total air volume of the ventilation system and maximum total pressure needed for the longest pipe line plus the pressure drop of the dust collector. Practical application showed that, after installation and use of the appropriate dust control measures, the dust concentrations in the workplaces could meet or nearly meet the national hygienic standard and the dust laden air at the local exhaust ventilation system could meet the national emission standard.
Thornberg, Steven M [Peralta, NM
2012-07-31
A system is provided for testing the hermeticity of a package, such as a microelectromechanical systems package containing a sealed gas volume, with a sampling device that has the capability to isolate the package and breach the gas seal connected to a pulse valve that can controllably transmit small volumes down to 2 nanoliters to a gas chamber for analysis using gas chromatography/mass spectroscopy diagnostics.
Dual Tasking and Working Memory in Alcoholism: Relation to Frontocerebellar Circuitry
Chanraud, Sandra; Pitel, Anne-Lise; Rohlfing, Torsten; Pfefferbaum, Adolf; Sullivan, Edith V
2010-01-01
Controversy exists regarding the role of cerebellar systems in cognition and whether working memory compromise commonly marking alcoholism can be explained by compromise of nodes of corticocerebellar circuitry. We tested 17 alcoholics and 31 age-matched controls with dual-task, working memory paradigms. Interference tasks competed with verbal and spatial working memory tasks using low (three item) or high (six item) memory loads. Participants also underwent structural MRI to obtain volumes of nodes of the frontocerebellar system. On the verbal working memory task, both groups performed equally. On the spatial working memory with the high-load task, the alcoholic group was disproportionately more affected by the arithmetic distractor than were controls. In alcoholics, volumes of the left thalamus and left cerebellar Crus I volumes were more robust predictors of performance in the spatial working memory task with the arithmetic distractor than the left frontal superior cortex. In controls, volumes of the right middle frontal gyrus and right cerebellar Crus I were independent predictors over the left cerebellar Crus I, left thalamus, right superior parietal cortex, or left middle frontal gyrus of spatial working memory performance with tracking interference. The brain–behavior correlations suggest that alcoholics and controls relied on the integrity of certain nodes of corticocerebellar systems to perform these verbal and spatial working memory tasks, but that the specific pattern of relationships differed by group. The resulting brain structure–function patterns provide correlational support that components of this corticocerebellar system not typically related to normal performance in dual-task conditions may be available to augment otherwise dampened performance by alcoholics. PMID:20410871
1984-08-01
and FPS-60 -’ vacuum-tube radars. There will be remote control interface units ( RCIU ) for tube-type radars, and an ARSR-3 relocation and RIH package...Facility RCE Remote Control Equipment; Radio Control Equipment RCIU Remote Control Interface Units RCO Remote Communications Outlet RDCC Research
1986-12-01
graphics : The package allows a character set which can be defined by users giving the picture for a character by designating its pixels. Such characters...type lonts and gsei-oriented "help" messages tailored to the operations being performed and user expertise In general, critical design issues...other volumes include command language, software design , description and analysis tools, database management system operating systems; planning and
Outer planet entry probe system study. Volume 4: Common Saturn/Uranus probe studies
NASA Technical Reports Server (NTRS)
1973-01-01
Results are summarized of a common scientific probe study to explore the atmospheres of Saturn and Uranus. This was a three-month follow-on effort to the Outer Planet Entry Probe System study. The report presents: (1) a summary, conclusions and recommendations of this study, (2) parametric analysis conducted to support the two system definitions, (3) common Saturn/Uranus probe system definition using the Science Advisory Group's exploratory payload and, (4) common Saturn/Uranus probe system definition using an expanded science complement. Each of the probe system definitions consists of detailed discussions of the mission, science, system and subsystems including telecommunications, data handling, power, pyrotechnics, attitude control, structures, propulsion, thermal control and probe-to-spacecraft integration. References are made to the contents of the first three volumes where it is feasible to do so.
NASA Technical Reports Server (NTRS)
1980-01-01
Project planning data for a rotor and control system procurement and testing program for modifications to the XV-15 tilt-rotor research demonstrator aircraft is presented. The design, fabrication, and installation of advanced composite blades compatible with the existing hub, an advanced composite hub, and a nonmechanical control system are required.
Waterflood control system for maximizing total oil recovery
Patzek, Tadeusz Wiktor; Silin, Dimitriy Borisovic; De, Asoke Kumar
2005-06-07
A control system and method for determining optimal fluid injection pressure is based upon a model of a growing hydrofracture due to waterflood injection pressure. This model is used to develop a control system optimizing the injection pressure by using a prescribed injection goal coupled with the historical times, pressures, and volume of injected fluid at a single well. In this control method, the historical data is used to derive two major flow components: the transitional component, where cumulative injection volume is scaled as the square root of time, and a steady-state breakthrough component, which scales linearly with respect to time. These components provide diagnostic information and allow for the prevention of rapid fracture growth and associated massive water break through that is an important part of a successful waterflood, thereby extending the life of both injection and associated production wells in waterflood secondary oil recovery operations.
Waterflood control system for maximizing total oil recovery
Patzek, Tadeusz Wiktor [Oakland, CA; Silin, Dimitriy Borisovich [Pleasant Hill, CA; De, Asoke Kumar [San Jose, CA
2007-07-24
A control system and method for determining optimal fluid injection pressure is based upon a model of a growing hydrofracture due to waterflood injection pressure. This model is used to develop a control system optimizing the injection pressure by using a prescribed injection goal coupled with the historical times, pressures, and volume of injected fluid at a single well. In this control method, the historical data is used to derive two major flow components: the transitional component, where cumulative injection volume is scaled as the square root of time, and a steady-state breakthrough component, which scales linearly with respect to time. These components provide diagnostic information and allow for the prevention of rapid fracture growth and associated massive water break through that is an important part of a successful waterflood, thereby extending the life of both injection and associated production wells in waterflood secondary oil recovery operations.
A ground based phase control system for the solar power satellite, volume 4
NASA Technical Reports Server (NTRS)
Chie, C. M.
1980-01-01
A ground phase control system is studied as an alternative approach to the current reference retrodirective phase control system in order to simplify the spaceborne hardware requirement. Based on waveform selections, functional subsystems to implement the ground-based phase control concept are identified and functionally represented. It was concluded that the feasibility of the concept becomes unclear if the conditions of the ionosphere and satellite motion are not met.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greene, N.M.; Petrie, L.M.; Westfall, R.M.
SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system hasmore » been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation; Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries.« less
Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas
2017-09-01
Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
1972-01-01
The overall program background, the various system concepts considered, and the rationale for the selected design are described. The concepts for each subsystem are also described and compared. Details are given for the requirements, boom configuration and dynamics, actuators, man/machine interface and control, visual system, control system, environmental control and life support, data processing, and materials.
Optimum aerobic volume control based on continuous in-line oxygen uptake monitoring.
Svardal, K; Lindtner, S; Winkler, S
2003-01-01
Dynamic adaptation of the aerated volume to changing load conditions is essential to maximise the nitrogen removal performance and to minimise energy consumption. A control strategy is presented which provides optimum aerobic volume control (OAV-control concept) based on continuous in-line oxygen uptake monitoring. For ammonium concentrations below 1 mg/l the oxygen uptake rate shows a strong and almost linear dependency on the ammonium concentration. Therefore, the oxygen uptake rate is an ideal indicator for the nitrification performance in activated sludge systems. The OAV-control concept provides dynamic variation of the minimum aerobic volume required for complete nitrification and therefore maximises the denitrification performance. In-line oxygen uptake monitoring is carried out by controlling the oxygen concentration in a continuous aerated zone of the aeration tank and measuring the total air flow to the aeration tank. The total air flow to the aeration tank is directly proportional to the current oxygen uptake rate and can therefore be used as an indicator for the required aerobic volume. The instrumentation requirements for installation of the OAV-control are relatively low, oxygen sensors in the aeration tank and an on-line air flow measurement are needed. This enables individual control of aeration tanks operated in parallel at low investment costs. The OAV-control concept is installed at the WWTP Linz-Asten (1 Mio PE) and shows very good results. Full scale results are presented.
Geostationary Operational Environmental Satellite (GOES-N report). Volume 1: Technical
NASA Technical Reports Server (NTRS)
1991-01-01
The GOES-N study consisted of five distinct tasks including: determining replication costs of GOES I-M and GOES-7 in the GOES-N time frame; defining and evaluating modifications to GOES I-M to improve efficiency or reduce costs; and defining evolutionary changes to the GOES I-M design to satisfy National Weather Service (NWS) 1983 and NOAA 1989 requirements. The categorization and disposition of NOAA requirements is reported in volume 1 section 4. Results of the GOES I-M efficiency/cost improvement modifications study are described in Section 7.1. The system concept options 1, 2, and 3 that generally represent the results of the Task 2, 3A, and 3B studies are summarized in Section 7.2. Another result of the GOES-N study, the determination of which NWS 1983 and NOAA 1989 requirements can be met with the three options, is contained in volume 1 section 7. Conclusions and recommendations are covered in volume 1 section 8. Imager, sounder, control system, space environment monitor, search and rescue, weather facsimile, data collection system, and products/process/communications recommendations were extracted from sections 9, 10, and 11. Section 8 also contains conclusions pertaining to programmatic operational satellite issues (prerequisite development strategies, the direct procurement of instruments by the government, protoflight mission, etc.). Sections 9, 10, and 11 address instrument, control system, image/navigation/registration, and other system design considerations and surveys. These sections are supported by the appendices in volume 2.
Geostationary Operational Environmental Satellite (GOES-N report). Volume 1: Technical
NASA Astrophysics Data System (ADS)
1991-12-01
The GOES-N study consisted of five distinct tasks including: determining replication costs of GOES I-M and GOES-7 in the GOES-N time frame; defining and evaluating modifications to GOES I-M to improve efficiency or reduce costs; and defining evolutionary changes to the GOES I-M design to satisfy National Weather Service (NWS) 1983 and NOAA 1989 requirements. The categorization and disposition of NOAA requirements is reported in volume 1 section 4. Results of the GOES I-M efficiency/cost improvement modifications study are described in Section 7.1. The system concept options 1, 2, and 3 that generally represent the results of the Task 2, 3A, and 3B studies are summarized in Section 7.2. Another result of the GOES-N study, the determination of which NWS 1983 and NOAA 1989 requirements can be met with the three options, is contained in volume 1 section 7. Conclusions and recommendations are covered in volume 1 section 8. Imager, sounder, control system, space environment monitor, search and rescue, weather facsimile, data collection system, and products/process/communications recommendations were extracted from sections 9, 10, and 11. Section 8 also contains conclusions pertaining to programmatic operational satellite issues (prerequisite development strategies, the direct procurement of instruments by the government, protoflight mission, etc.). Sections 9, 10, and 11 address instrument, control system, image/navigation/registration, and other system design considerations and surveys. These sections are supported by the appendices in volume 2.
Individual Global Navigation Satellite Systems in the Space Service Volume
NASA Technical Reports Server (NTRS)
Force, Dale A.
2015-01-01
Besides providing position, navigation, and timing (PNT) to terrestrial users, GPS is currently used to provide for precision orbit determination, precise time synchronization, real-time spacecraft navigation, and three-axis control of Earth orbiting satellites. With additional Global Navigation Satellite Systems (GNSS) coming into service (GLONASS, Beidou, and Galileo), it will be possible to provide these services by using other GNSS constellations. The paper, "GPS in the Space Service Volume," presented at the ION GNSS 19th International Technical Meeting in 2006 (Ref. 1), defined the Space Service Volume, and analyzed the performance of GPS out to 70,000 km. This paper will report a similar analysis of the performance of each of the additional GNSS and compare them with GPS alone. The Space Service Volume, defined as the volume between 3,000 km altitude and geosynchronous altitude, as compared with the Terrestrial Service Volume between the surface and 3,000 km. In the Terrestrial Service Volume, GNSS performance will be similar to performance on the Earth's surface. The GPS system has established signal requirements for the Space Service Volume. A separate paper presented at the conference covers the use of multiple GNSS in the Space Service Volume.
Ubiquitous Wireless Smart Sensing and Control
NASA Technical Reports Server (NTRS)
Wagner, Raymond
2013-01-01
Need new technologies to reliably and safely have humans interact within sensored environments (integrated user interfaces, physical and cognitive augmentation, training, and human-systems integration tools). Areas of focus include: radio frequency identification (RFID), motion tracking, wireless communication, wearable computing, adaptive training and decision support systems, and tele-operations. The challenge is developing effective, low cost/mass/volume/power integrated monitoring systems to assess and control system, environmental, and operator health; and accurately determining and controlling the physical, chemical, and biological environments of the areas and associated environmental control systems.
Ubiquitous Wireless Smart Sensing and Control. Pumps and Pipes JSC: Uniquely Houston
NASA Technical Reports Server (NTRS)
Wagner, Raymond
2013-01-01
Need new technologies to reliably and safely have humans interact within sensored environments (integrated user interfaces, physical and cognitive augmentation, training, and human-systems integration tools).Areas of focus include: radio frequency identification (RFID), motion tracking, wireless communication, wearable computing, adaptive training and decision support systems, and tele-operations. The challenge is developing effective, low cost/mass/volume/power integrated monitoring systems to assess and control system, environmental, and operator health; and accurately determining and controlling the physical, chemical, and biological environments of the areas and associated environmental control systems.
Proceedings of the NASA Conference on Space Telerobotics, volume 4
NASA Technical Reports Server (NTRS)
Rodriguez, Guillermo (Editor); Seraji, Homayoun (Editor)
1989-01-01
Papers presented at the NASA Conference on Space Telerobotics are compiled. The theme of the conference was man-machine collaboration in space. The conference provided a forum for researchers and engineers to exchange ideas on the research and development required for the application of telerobotic technology to the space systems planned for the 1990's and beyond. Volume 4 contains papers related to the following subject areas: manipulator control; telemanipulation; flight experiments (systems and simulators); sensor-based planning; robot kinematics, dynamics, and control; robot task planning and assembly; and research activities at the NASA Langley Research Center.
Proceedings of the NASA Conference on Space Telerobotics, volume 5
NASA Technical Reports Server (NTRS)
Rodriguez, Guillermo (Editor); Seraji, Homayoun (Editor)
1989-01-01
Papers presented at the NASA Conference on Space Telerobotics are compiled. The theme of the conference was man-machine collaboration in space. The conference provided a forum for researchers and engineers to exchange ideas on the research and development required for the application of telerobotics technology to the space systems planned for the 1990's and beyond. Volume 5 contains papers related to the following subject areas: robot arm modeling and control, special topics in telerobotics, telerobotic space operations, manipulator control, flight experiment concepts, manipulator coordination, issues in artificial intelligence systems, and research activities at the Johnson Space Center.
ERIC Educational Resources Information Center
Smith, Ernest K.; And Others
The system control facilities in broadband communication systems are discussed in this report. These facilities consist of head-ends and central processors. The first section summarizes technical problems and needs, and the second offers a cursory overview of systems, along with an incidental mention of processors. Section 3 looks at the question…
Erratum: Erratum to Central European Journal of Engineering, Volume 4, Issue 1
NASA Astrophysics Data System (ADS)
Kumar, M. Ajay; Srikanth, N. V.
2014-06-01
Paper by M. Ajay Kumar, N. V. Srikanth, et al. "An adaptive neuro fuzzy inference system controlled space cector pulse width modulation based HVDC light transmission system under AC fault conditions" in Volume 4, Issue 1, 27-38/March 2014 doi: 10.2478/s13531-013-0143-4 contains an error in the title. The correct title is presented below
Packaged peristaltic micropump for controlled drug delivery application
NASA Astrophysics Data System (ADS)
Vinayakumar, K. B.; Nadiger, Girish; R. Shetty, Vikas; Dinesh, N. S.; Nayak, M. M.; Rajanna, K.
2017-01-01
Micropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from μTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application. All the micropump components were fabricated using the conventional fabrication technique. The volume flow variation of the pump has been characterized for different viscous fluids. The change in volume flow due to change in back pressure has been presented in detail. The fail-safe mode operation of the pump has been tested and leak rate was measured (˜0.14% leak for an inlet pressure of 140 kPa) for different inlet pressures. The precision volume flow of the pump has been achieved by measuring the pinch cam position and load current. The accuracy in the volume flow has been measured after 300 rotations. Finally, the complete system has been integrated with the necessary electronics and an android application has been developed for the self-administration of bolus and basal delivery of insulin.
1988-07-29
VOLff2) 6 July 19837 A-74 A1.5.6 MONITORING NON-CONTROLLED OBJECTS AIM, 7 OIHERS REPORT AIRSPACEJ FIRST 10 DETECT INTRUSION IradR’SIoN BY NON-CON’TROLLED 1...1988 Volume II: ACF/ACCC Terminal and En Route Controllers (ClIG 1) 6 . Porliming Organization Code 7 . Author(s) 8. Performing Organization Report No...MANEUVER SYSTEM GENERATES ABSORPT ION PREVIOUSLY PREPARED RECEIVED MANEUVER FOR A FLIGHT CLEAPANCEI D0T/FAA/AP-47-01 (VOLt2) 6 July 1987 A- 7 A,1.O
NASA Technical Reports Server (NTRS)
Birr, Richard B.; Spencer, Roy; Murray, Jennifer; Lash, Andrew
2013-01-01
This report describes the analysis of communications between the Control Station and an Unmanned Aircraft (UA) flying in the National Airspace System (NAS). This work is based on the RTCA SC-203 Operational Services and Environment Description (OSED). The OSED document seeks to characterize the highly different attributes of all UAs navigating the airspace and define their relationship to airspace users, air traffic services, and operating environments of the NAS. One goal of this report is to lead to the development of Minimum Aviation System Performance Standards for Control and Communications. This report takes the nine scenarios found in the OSED and analyzes the communication links.
Franzoso, Francesca D; Wohlmuth, Christoph; Greutmann, Matthias; Kellenberger, Christian J; Oxenius, Angela; Voser, Eva M; Valsangiacomo Buechel, Emanuela R
2016-09-01
The atria serve as reservoir, conduit, and active pump for ventricular filling. The performance of the atrial baffles after atrial switch repair for transposition of the great arteries may be abnormal and impact the function of the systemic right ventricle. We sought to assess atrial function in patients after atrial repair in comparison to patients after arterial switch repair (ASO) and to controls. Using magnetic resonance imaging, atrial volumes and functional parameters were measured in 17 patients after atrial switch repair, 9 patients after ASO and 10 healthy subjects. After the atrial switch operation, the maximum volume of the pulmonary venous atrium was significantly enlarged, but not of the systemic venous atrium. In both patients groups, independently from the surgical technique used, the minimum atrial volumes were elevated, which resulted in a decreased total empting fraction compared with controls (P < .01). The passive empting volume was diminished for right atrium, but elevated for left atrium after atrial switch and normal for left atrium after ASO; however, the passive empting fraction was diminished for both right atrium and left atrium after both operations (P < .01). The active empting volume was the most affected parameter in both atria and both groups and active empting fractions were highly significantly reduced compared with controls. Atrial function is abnormal in all patients, after atrial switch and ASO repair. The cyclic volume changes, that is, atrial filling and empting, are reduced when compared with normal subjects. Thus, the atria have lost part of their capacity to convert continuous venous flow into a pulsatile ventricular filling. The function of the pulmonary venous atrium, acting as preload for the systemic right ventricle, after atrial switch is altered the most. © 2015 Wiley Periodicals, Inc.
Optimal ventilation of the anesthetized pediatric patient.
Feldman, Jeffrey M
2015-01-01
Mechanical ventilation of the pediatric patient is challenging because small changes in delivered volume can be a significant fraction of the intended tidal volume. Anesthesia ventilators have traditionally been poorly suited to delivering small tidal volumes accurately, and pressure-controlled ventilation has become used commonly when caring for pediatric patients. Modern anesthesia ventilators are designed to deliver small volumes accurately to the patient's airway by compensating for the compliance of the breathing system and delivering tidal volume independent of fresh gas flow. These technology advances provide the opportunity to implement a lung-protective ventilation strategy in the operating room based upon control of tidal volume. This review will describe the capabilities of the modern anesthesia ventilator and the current understanding of lung-protective ventilation. An optimal approach to mechanical ventilation for the pediatric patient is described, emphasizing the importance of using bedside monitors to optimize the ventilation strategy for the individual patient.
Flexible Manufacturing System Handbook. Volume II. Description of the Technology
1983-02-01
hubs, or wheels with considerable 4 FM5 Handbook, Volume II milling, drilling and/or tapping, are usually candidates for inclusion in a prismatic...0.06 inch) to transfer pallets to a machine or unload station. Wheel encoders can be used as less precise feedback for the drive system and its...must be used to control pallet transfer. The Cincinnati Milacron Variable Mission System uses this type of MHS, specifically the Eaton-Kenway Robo
NASA Technical Reports Server (NTRS)
Osder, S.; Keller, R.
1971-01-01
Guidance and control design studies that were performed for three specific space shuttle candidate vehicles are described. Three types of simulation were considered. The manual control investigations and pilot evaluations of the automatic system performance is presented. Recommendations for systems and equipment, both airborne and ground-based, necessary to flight test the guidance and control concepts for shuttlecraft terminal approach and landing are reported.
NASA Technical Reports Server (NTRS)
1983-01-01
Mission scenarios and space station architectures are discussed. Electrical power subsystems (EPS), environmental control and life support, subsystems (ECLSS), and reaction control subsystem (RCS) architectures are addressed. Thermal control subsystems, (TCS), guidance/navigation and control (GN and C), information management systems IMS), communications and tracking (C and T), and propellant transfer and storage systems architectures are discussed.
NASA Technical Reports Server (NTRS)
1975-01-01
A shuttle EVLSS Thermal Control System (TCS) is defined. Thirteen heat rejection subsystems, thirteen water management subsystems, nine humidity control subsystems, three pressure control schemes and five temperature control schemes are evaluated. Sixteen integrated TCS systems are studied, and an optimum system is selected based on quantitative weighting of weight, volume, cost, complexity and other factors. The selected sybsystem contains a sublimator for heat rejection, a bubble expansion tank for water management, and a slurper and rotary separator for humidity control. Design of the selected subsystem prototype hardware is presented.
A Vertically Lagrangian Finite-Volume Dynamical Core for Global Models
NASA Technical Reports Server (NTRS)
Lin, Shian-Jiann
2003-01-01
A finite-volume dynamical core with a terrain-following Lagrangian control-volume discretization is described. The vertically Lagrangian discretization reduces the dimensionality of the physical problem from three to two with the resulting dynamical system closely resembling that of the shallow water dynamical system. The 2D horizontal-to-Lagrangian-surface transport and dynamical processes are then discretized using the genuinely conservative flux-form semi-Lagrangian algorithm. Time marching is split- explicit, with large-time-step for scalar transport, and small fractional time step for the Lagrangian dynamics, which permits the accurate propagation of fast waves. A mass, momentum, and total energy conserving algorithm is developed for mapping the state variables periodically from the floating Lagrangian control-volume to an Eulerian terrain-following coordinate for dealing with physical parameterizations and to prevent severe distortion of the Lagrangian surfaces. Deterministic baroclinic wave growth tests and long-term integrations using the Held-Suarez forcing are presented. Impact of the monotonicity constraint is discussed.
Advanced Extravehicular Protective Systems (AEPS) study
NASA Technical Reports Server (NTRS)
Williams, J. L.; Copeland, R. J.; Webbon, B. W.
1971-01-01
A description is given of life support subsystem concepts for advanced extravehicular protective systems (AEPS) intended for use on future orbital, lunar surface, and Mars surface missions in the late 1970's and 1980's. Primary interest was centered around the thermal control and carbon dioxide control subsystems because they offer the greatest potential for total weight savings. Emphasis was placed on the generation of regenerable subsystem concepts; however, partially regenerable and expendable concepts were also considered. Previously conceived and developed subsystem concepts were included in the study. Concepts were evaluated on the basis of subsystem weight and volume, and subsystem contribution to parent vehicle weight and volume, which included spares, regeneration equipment, expendables, expandables storage penalty, power penalty, and process heating or cooling penalty. Results are presented showing total weight and volume penalty as a function of total mission extravehicular activity (EVA) hours, and showing EVA weight and volume as a function of EVA duration. Subsystem concepts are recommended for each life support function, and secondary concepts which should be developed are also identified.
NASA Technical Reports Server (NTRS)
1979-01-01
An array deployment assembly, power regulation and control assembly, the necessary interface, and display and control equipment comprise the power extension package (PEP) which is designed to provide increased power and duration, as well as reduce fuel cell cryogen consumption during Spacelab missions. Compatible with all currently defined missions and payloads, PEP imposes minimal weight and volume penalties on sortie missions, and can be installed and removed as needed at the launch site within the normal Orbiter turnaround cycle. The technology on which it is based consists of a modified solar electric propulsion array, standard design regulator and control equipment, and a minimally modified Orbiter design. The requirements from which PEP was derived, and the system and its performance capabilities are described. Features of the recommended project are presented.
Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto
2002-09-01
Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore PMM. V(te), as measured by the VIP Bird and Drager paired with the Ventrak PMM, had a tendency to underestimate V(t) by up to 25% at the smallest V(te). However, when paired with the Bicore PMM, these same two ventilators read over target by up to 18%. Under controlled laboratory conditions, we demonstrated that true delivered V(te), as measured by the three ventilators and two freestanding PMM, differed markedly. In general, decreasing dynamic compliance of the tubing was not associated with greater inaccuracy in V(te) measurements. Copyright 2002 Wiley-Liss, Inc.
NASA Technical Reports Server (NTRS)
Amar, Adam J.; Blackwell, Ben F.; Edwards, Jack R.
2007-01-01
The development and verification of a one-dimensional material thermal response code with ablation is presented. The implicit time integrator, control volume finite element spatial discretization, and Newton's method for nonlinear iteration on the entire system of residual equations have been implemented and verified for the thermochemical ablation of internally decomposing materials. This study is a continuation of the work presented in "One-Dimensional Ablation with Pyrolysis Gas Flow Using a Full Newton's Method and Finite Control Volume Procedure" (AIAA-2006-2910), which described the derivation, implementation, and verification of the constant density solid energy equation terms and boundary conditions. The present study extends the model to decomposing materials including decomposition kinetics, pyrolysis gas flow through the porous char layer, and a mixture (solid and gas) energy equation. Verification results are presented for the thermochemical ablation of a carbon-phenolic ablator which involves the solution of the entire system of governing equations.
Manor, Brad; Newton, Elizabeth; Abduljalil, Amir; Novak, Vera
2012-09-01
Diabetic peripheral neuropathy (DPN) alters walking. Yet, the compensatory role of central locomotor circuits remains unclear. We hypothesized that walking outcomes would be more closely related to regional gray matter volumes in older adults with DPN as compared with nonneuropathic diabetic patients and nondiabetic control subjects. Clinically important outcomes of walking (i.e., speed, stride duration variability, and double support time) were measured in 29 patients with DPN (type 2 diabetes with foot-sole somatosensory impairment), 68 diabetic (DM) patients (type 2 diabetes with intact foot-sole sensation), and 89 control subjects. Global and regional gray matter volumes were calculated from 3 Tesla magnetic resonance imaging. DPN subjects walked more slowly (P = 0.005) with greater stride duration variability (P < 0.001) and longer double support (P < 0.001) as compared with DM and control subjects. Diabetes was associated with less cerebellar gray matter volume (P < 0.001), but global gray matter volume was similar between groups. DPN subjects with lower gray matter volume globally (P < 0.004) and regionally (i.e., cerebellum, right-hemisphere dorsolateral prefrontal cortex, basal ganglia, P < 0.005) walked more slowly with greater stride duration variability and/or longer double support. Each relationship was stronger in DPN than DM subjects. In control subjects, brain volumes did not relate to walking patterns. Strong relationships between brain volumes and walking outcomes were observed in the DPN group and to a lesser extent the DM group, but not in control subjects. Individuals with DPN may be more dependent upon supraspinal elements of the motor control system to regulate several walking outcomes linked to poor health in elderly adults.
Manor, Brad; Newton, Elizabeth; Abduljalil, Amir; Novak, Vera
2012-01-01
OBJECTIVE Diabetic peripheral neuropathy (DPN) alters walking. Yet, the compensatory role of central locomotor circuits remains unclear. We hypothesized that walking outcomes would be more closely related to regional gray matter volumes in older adults with DPN as compared with nonneuropathic diabetic patients and nondiabetic control subjects. RESEARCH DESIGN AND METHODS Clinically important outcomes of walking (i.e., speed, stride duration variability, and double support time) were measured in 29 patients with DPN (type 2 diabetes with foot-sole somatosensory impairment), 68 diabetic (DM) patients (type 2 diabetes with intact foot-sole sensation), and 89 control subjects. Global and regional gray matter volumes were calculated from 3 Tesla magnetic resonance imaging. RESULTS DPN subjects walked more slowly (P = 0.005) with greater stride duration variability (P < 0.001) and longer double support (P < 0.001) as compared with DM and control subjects. Diabetes was associated with less cerebellar gray matter volume (P < 0.001), but global gray matter volume was similar between groups. DPN subjects with lower gray matter volume globally (P < 0.004) and regionally (i.e., cerebellum, right-hemisphere dorsolateral prefrontal cortex, basal ganglia, P < 0.005) walked more slowly with greater stride duration variability and/or longer double support. Each relationship was stronger in DPN than DM subjects. In control subjects, brain volumes did not relate to walking patterns. CONCLUSIONS Strong relationships between brain volumes and walking outcomes were observed in the DPN group and to a lesser extent the DM group, but not in control subjects. Individuals with DPN may be more dependent upon supraspinal elements of the motor control system to regulate several walking outcomes linked to poor health in elderly adults. PMID:22665216
NASA Astrophysics Data System (ADS)
Li, Yi; Ye, Quanliang; Liu, An; Meng, Fangang; Zhang, Wenlong; Xiong, Wei; Wang, Peifang; Wang, Chao
2017-07-01
Urban rainwater management need to achieve an optimal compromise among water resource augmentation, water loggings alleviation, economic investment and pollutants reduction. Rainwater harvesting (RWH) systems, such as green rooftops, porous pavements, and green lands, have been successfully implemented as viable approaches to alleviate water-logging disasters and water scarcity problems caused by rapid urbanization. However, there is limited guidance to determine the construction areas of RWH systems, especially for stormwater runoff control due to increasing extreme precipitation. This study firstly developed a multi-objective model to optimize the construction areas of green rooftops, porous pavements and green lands, considering the trade-offs among 24 h-interval RWH volume, stormwater runoff volume control ratio (R), economic cost, and rainfall runoff pollutant reduction. Pareto fronts of RWH system areas for 31 provinces of China were obtained through nondominated sorting genetic algorithm. On the national level, the control strategies for the construction rate (the ratio between the area of single RWH system and the total areas of RWH systems) of green rooftops (ηGR), porous pavements (ηPP) and green lands (ηGL) were 12%, 26% and 62%, and the corresponding RWH volume and total suspended solids reduction was 14.84 billion m3 and 228.19 kilotons, respectively. Optimal ηGR , ηPP and ηGL in different regions varied from 1 to 33%, 6 to 54%, and 30 to 89%, respectively. Particularly, green lands were the most important RWH system in 25 provinces with ηGL more than 50%, ηGR mainly less than 15%, and ηPP mainly between 10 and 30%. Results also indicated whether considering the objective MaxR made a non-significant difference for RWH system areas whereas exerted a great influence on the result of stormwater runoff control. Maximum daily rainfall under control increased, exceeding 200% after the construction of the optimal RWH system compared with that before construction. Optimal RWH system areas presented a general picture for urban development policy makers in China.
Drijkoningen, David; Leunissen, Inge; Caeyenberghs, Karen; Hoogkamer, Wouter; Sunaert, Stefan; Duysens, Jacques; Swinnen, Stephan P
2015-12-01
Many patients with traumatic brain injury (TBI) suffer from postural control impairments that can profoundly affect daily life. The cerebellum and brain stem are crucial for the neural control of posture and have been shown to be vulnerable to primary and secondary structural consequences of TBI. The aim of this study was to investigate whether morphometric differences in the brain stem and cerebellum can account for impairments in static and dynamic postural control in TBI. TBI patients (n = 18) and healthy controls (n = 30) completed three challenging postural control tasks on the EquiTest® system (Neurocom). Infratentorial grey matter (GM) and white matter (WM) volumes were analyzed with cerebellum-optimized voxel-based morphometry using the spatially unbiased infratentorial toolbox. Volume loss in TBI patients was revealed in global cerebellar GM, global infratentorial WM, middle cerebellar peduncles, pons and midbrain. In the TBI group and across both groups, lower postural control performance was associated with reduced GM volume in the vermal/paravermal regions of lobules I-IV, V and VI. Moreover, across all participants, worse postural control performance was associated with lower WM volume in the pons, medulla, midbrain, superior and middle cerebellar peduncles and cerebellum. This is the first study in TBI patients to demonstrate an association between postural impairments and reduced volume in specific infratentorial brain areas. Volumetric measures of the brain stem and cerebellum may be valuable prognostic markers of the chronic neural pathology, which complicates rehabilitation of postural control in TBI. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Hymer, R. L.
1970-01-01
System provides automatic volume control for an audio amplifier or a voice communication system without introducing noise surges during pauses in the input, and without losing the initial signal when the input resumes.
NASA Technical Reports Server (NTRS)
Bartlett, R. G., Jr.
1973-01-01
The general anatomy and function of the human respiratory system is summarized. Breathing movements, control of breathing, lung volumes and capacities, mechanical relations, and factors relevant to respiratory support and equipment design are discussed.
Multi-purpose wind tunnel reaction control model block
NASA Technical Reports Server (NTRS)
Dresser, H. S.; Daileda, J. J. (Inventor)
1978-01-01
A reaction control system nozzle block is provided for testing the response characteristics of space vehicles to a variety of reaction control thruster configurations. A pressurized air system is connected with the supply lines which lead to the individual jet nozzles. Each supply line terminates in a compact cylindrical plenum volume, axially perpendicular and adjacent to the throat of the jet nozzle. The volume of the cylindrical plenum is sized to provide uniform thrust characteristics from each jet nozzle irrespective of the angle of approach of the supply line to the plenum. Each supply line may be plugged or capped to stop the air supply to selected jet nozzles, thereby enabling a variety of nozzle configurations to be obtained from a single model nozzle block.
ROMPS critical design review. Volume 1: Hardware
NASA Technical Reports Server (NTRS)
Dobbs, M. E.
1992-01-01
Topics concerning the Robot-Operated Material Processing in Space (ROMPS) Program are presented in viewgraph form and include the following: a systems overview; servocontrol and servomechanisms; testbed and simulation results; system V controller; robot module; furnace module; SCL experiment supervisor; SCL script sample processing control; SCL experiment supervisor fault handling; block diagrams; hitchhiker interfaces; battery systems; watchdog timers; mechanical/thermal systems; and fault conditions and recovery.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...
The C3-System User. Volume II. Workshop Notes
1977-02-01
system that provides the means for operational direction and technical administrative support involved in the function of command and control of U.S...information systems of the Headquarters of the Military Depart- ments; the command and control systems of the Headquarters of the Service Component Commands...the Service Component Commands - Military Airlift Command - Military Sealift Command - Military Traffic Management Command - 3.2.5 Command and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
Volume IV contains the following attachments for Module IV: VOC monitoring plan for bin-room tests (Appendix D12); bin emission control and VOC monitoring system drawings; bin scale test room ventilation drawings; WIPP supplementary roof support system, underground storage area, room 1, panel 1, DOE/WIPP 91-057; and WIPP supplementary roof support system, room 1, panel 1, geotechnical field data analysis bi-annual report, DOE/WIPP 92-024.
Dual-Use Space Technology Transfer Conference and Exhibition. Volume 2
NASA Technical Reports Server (NTRS)
Krishen, Kumar (Compiler)
1994-01-01
This is the second volume of papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools; systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development; perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; and robotics technologies.
The report gives results of an emission test of a new municipal solid waste combustor, in Biddeford, ME, that burns refuse-derived fuel and is equipped with a lime spray dryer fabric filter (SD/FF) emission control system. Control efficiency of the SD/FF emission control system ...
The report gives results of an emission test of a new municipal solid waste combustor, in Biddeford, ME, that burns refuse-derived fuel and is equipped with a lime spray dryer fabric filter (SD/FF) emission control system. Control efficiency of the SD/FF emission control system ...
NASA Technical Reports Server (NTRS)
Aucoin, P. J.; Stewart, J.; Mckay, M. F. (Principal Investigator)
1980-01-01
This document presents instructions for analysts who use the EOD-LARSYS as programmed on the Purdue University IBM 370/148 (recently replaced by the IBM 3031) computer. It presents sample applications, control cards, and error messages for all processors in the system and gives detailed descriptions of the mathematical procedures and information needed to execute the system and obtain the desired output. EOD-LARSYS is the JSC version of an integrated batch system for analysis of multispectral scanner imagery data. The data included is designed for use with the as built documentation (volume 3) and the program listings (volume 4). The system is operational from remote terminals at Johnson Space Center under the virtual machine/conversational monitor system environment.
Design requirements for SRB production control system. Volume 1: Study background and overview
NASA Technical Reports Server (NTRS)
1981-01-01
The solid rocket boosters assembly environment is described in terms of the contraints it places upon an automated production control system. The business system generated for the SRB assembly and the computer system which meets the business system requirements are described. The selection software process and modifications required to the recommended software are addressed as well as the hardware and configuration requirements necessary to support the system.
Collision avoidance system cost-benefit analysis : volume I - technical manual
DOT National Transportation Integrated Search
1981-09-01
Collision-avoidance systems under development in the U.S.A., Japan and Germany were evaluated. The performance evaluation showed that the signal processing and the control law of a system were the key parameters that decided the system's capability, ...
Smart Adaptive Socket to Improve Fit and Relieve Pain in Wounded Warriors
2016-10-01
applications were developed for wireless interaction with the socket system firmware. A control algorithm was designed and tested. Clinical trial...interface, Dynamic segmental volume control, Wireless connection, Pressure control system. 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18...charging jack, and power button are included in the design. A Bluetooth 4 radio is also included to allow for advanced user control via smartphone. The
Brazeau, Randi H.; Edwards, Marc A.
2013-01-01
Abstract Residential water heating is linked to growth of pathogens in premise plumbing, which is the primary source of waterborne disease in the United States. Temperature and disinfectant residual are critical factors controlling increased concentration of pathogens, but understanding of how each factor varies in different water heater configurations is lacking. A direct comparative study of electric water heater systems was conducted to evaluate temporal variations in temperature and water quality parameters including dissolved oxygen levels, hydrogen evolution, total and soluble metal concentrations, and disinfectant decay. Recirculation tanks had much greater volumes of water at temperature ranges with potential for increased pathogen growth when set at 49°C compared with standard tank systems without recirculation. In contrast, when set at the higher end of acceptable ranges (i.e., 60°C), this relationship was reversed and recirculation systems had less volume of water at risk for pathogen growth compared with conventional systems. Recirculation tanks also tended to have much lower levels of disinfectant residual (standard systems had 40–600% higher residual), 4–6 times as much hydrogen, and 3–20 times more sediment compared with standard tanks without recirculation. On demand tankless systems had very small volumes of water at risk and relatively high levels of disinfectant residual. Recirculation systems may have distinct advantages in controlling pathogens via thermal disinfection if set at 60°C, but these systems have lower levels of disinfectant residual and greater volumes at risk if set at lower temperatures. PMID:24170969
Cardiovascular and fluid volume control in humans in space.
Norsk, Peter
2005-08-01
The human cardiovascular system and regulation of fluid volume are heavily influenced by gravity. When decreasing the effects of gravity in humans such as by anti-orthostatic posture changes or immersion into water, venous return is increased by some 25%. This leads to central blood volume expansion, which is accompanied by an increase in renal excretion rates of water and sodium. The mechanisms for the changes in renal excretory rates include a complex interaction of cardiovascular reflexes, neuroendocrine variables, and physical factors. Weightlessness is unique to obtain more information on this complex interaction, because it is the only way to completely abolish the effects of gravity over longer periods. Results from space have been unexpected, because astronauts exhibit a fluid and sodium retaining state with activation of the sympathetic nervous system, which subjects during simulations by head-down bed rest do not. Therefore, the concept as to how weightlessness affects the cardiovascular system and modulates regulation of body fluids should be revised and new simulation models developed. Knowledge as to how gravity and weightlessness modulate integrated fluid volume control is of importance for understanding pathophysiology of heart failure, where gravity plays a strong role in fluid and sodium retention.
Techniques for optimal crop selection in a controlled ecological life support system
NASA Technical Reports Server (NTRS)
Mccormack, Ann; Finn, Cory; Dunsky, Betsy
1993-01-01
A Controlled Ecological Life Support System (CELSS) utilizes a plant's natural ability to regenerate air and water while being grown as a food source in a closed life support system. Current plant research is directed toward obtaining quantitative empirical data on the regenerative ability of each species of plant and the system volume and power requirements. Two techniques were adapted to optimize crop species selection while at the same time minimizing the system volume and power requirements. Each allows the level of life support supplied by the plants to be selected, as well as other system parameters. The first technique uses decision analysis in the form of a spreadsheet. The second method, which is used as a comparison with and validation of the first, utilizes standard design optimization techniques. Simple models of plant processes are used in the development of these methods.
Techniques for optimal crop selection in a controlled ecological life support system
NASA Technical Reports Server (NTRS)
Mccormack, Ann; Finn, Cory; Dunsky, Betsy
1992-01-01
A Controlled Ecological Life Support System (CELSS) utilizes a plant's natural ability to regenerate air and water while being grown as a food source in a closed life support system. Current plant research is directed toward obtaining quantitative empirical data on the regenerative ability of each species of plant and the system volume and power requirements. Two techniques were adapted to optimize crop species selection while at the same time minimizing the system volume and power requirements. Each allows the level of life support supplied by the plants to be selected, as well as other system parameters. The first technique uses decision analysis in the form of a spreadsheet. The second method, which is used as a comparison with and validation of the first, utilizes standard design optimization techniques. Simple models of plant processes are used in the development of these methods.
Control volume based hydrocephalus research; a phantom study
NASA Astrophysics Data System (ADS)
Cohen, Benjamin; Voorhees, Abram; Madsen, Joseph; Wei, Timothy
2009-11-01
Hydrocephalus is a complex spectrum of neurophysiological disorders involving perturbation of the intracranial contents; primarily increased intraventricular cerebrospinal fluid (CSF) volume and intracranial pressure are observed. CSF dynamics are highly coupled to the cerebral blood flows and pressures as well as the mechanical properties of the brain. Hydrocephalus, as such, is a very complex biological problem. We propose integral control volume analysis as a method of tracking these important interactions using mass and momentum conservation principles. As a first step in applying this methodology in humans, an in vitro phantom is used as a simplified model of the intracranial space. The phantom's design consists of a rigid container filled with a compressible gel. Within the gel a hollow spherical cavity represents the ventricular system and a cylindrical passage represents the spinal canal. A computer controlled piston pump supplies sinusoidal volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity and volume change as functions of time. Independent pressure measurements and momentum flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients and normal individuals. Flow and pressure measurements on the flow phantom will be presented through the control volume framework.
Precise nanoliter fluid handling system with integrated high-speed flow sensor.
Haber, Carsten; Boillat, Marc; van der Schoot, Bart
2005-04-01
A system for accurate low-volume delivery of liquids in the micro- to nanoliter range makes use of an integrated miniature flow sensor as part of an intelligent feedback control loop driving a micro-solenoid valve. The flow sensor is hydraulically connected with the pressurized system liquid in the dispensing channel and located downstream from the pressure source, above the solenoid valve. The sensor operates in a differential mode and responds in real-time to the internal flow-pulse resulting from the brief opening interval of the solenoid valve leading to a rapid ejection of a fluid droplet. The integral of the flow-pulse delivered by the sensor is directly proportional to the volume of the ejected droplet from the nozzle. The quantitative information is utilized to provide active control of the effectively dispensed or aspirated volume by adjusting the solenoid valve accordingly. This process significantly enhances the precision of the fluid delivery. The system furthermore compensates automatically for any changes in the viscosity of the dispensed liquid. The data delivered by the flow sensor can be saved and backtracked in order to confirm and validate the aspiration and dispensing process in its entirety. The collected dispense information can be used for quality control assessments and automatically be made part of an electronic record.
Space station systems technology study (add-on task). Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1985-01-01
System concepts were characterized in order to define cost versus benefits for autonomous functional control and for controls and displays for OMV, OTV, and spacecraft servicing and operation. The attitude control topic focused on characterizing the Space Station attitude control problem through simulation of control system responses to structural disturbances. The first two topics, mentioned above, focused on specific technology items that require advancement in order to support an early 1990s initial launch of a Space Station, while the attitude control study was an exploration of the capability of conventional controller techniques.
A 3D Freehand Ultrasound System for Multi-view Reconstructions from Sparse 2D Scanning Planes
2011-01-01
Background A significant limitation of existing 3D ultrasound systems comes from the fact that the majority of them work with fixed acquisition geometries. As a result, the users have very limited control over the geometry of the 2D scanning planes. Methods We present a low-cost and flexible ultrasound imaging system that integrates several image processing components to allow for 3D reconstructions from limited numbers of 2D image planes and multiple acoustic views. Our approach is based on a 3D freehand ultrasound system that allows users to control the 2D acquisition imaging using conventional 2D probes. For reliable performance, we develop new methods for image segmentation and robust multi-view registration. We first present a new hybrid geometric level-set approach that provides reliable segmentation performance with relatively simple initializations and minimum edge leakage. Optimization of the segmentation model parameters and its effect on performance is carefully discussed. Second, using the segmented images, a new coarse to fine automatic multi-view registration method is introduced. The approach uses a 3D Hotelling transform to initialize an optimization search. Then, the fine scale feature-based registration is performed using a robust, non-linear least squares algorithm. The robustness of the multi-view registration system allows for accurate 3D reconstructions from sparse 2D image planes. Results Volume measurements from multi-view 3D reconstructions are found to be consistently and significantly more accurate than measurements from single view reconstructions. The volume error of multi-view reconstruction is measured to be less than 5% of the true volume. We show that volume reconstruction accuracy is a function of the total number of 2D image planes and the number of views for calibrated phantom. In clinical in-vivo cardiac experiments, we show that volume estimates of the left ventricle from multi-view reconstructions are found to be in better agreement with clinical measures than measures from single view reconstructions. Conclusions Multi-view 3D reconstruction from sparse 2D freehand B-mode images leads to more accurate volume quantification compared to single view systems. The flexibility and low-cost of the proposed system allow for fine control of the image acquisition planes for optimal 3D reconstructions from multiple views. PMID:21251284
A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes.
Yu, Honggang; Pattichis, Marios S; Agurto, Carla; Beth Goens, M
2011-01-20
A significant limitation of existing 3D ultrasound systems comes from the fact that the majority of them work with fixed acquisition geometries. As a result, the users have very limited control over the geometry of the 2D scanning planes. We present a low-cost and flexible ultrasound imaging system that integrates several image processing components to allow for 3D reconstructions from limited numbers of 2D image planes and multiple acoustic views. Our approach is based on a 3D freehand ultrasound system that allows users to control the 2D acquisition imaging using conventional 2D probes.For reliable performance, we develop new methods for image segmentation and robust multi-view registration. We first present a new hybrid geometric level-set approach that provides reliable segmentation performance with relatively simple initializations and minimum edge leakage. Optimization of the segmentation model parameters and its effect on performance is carefully discussed. Second, using the segmented images, a new coarse to fine automatic multi-view registration method is introduced. The approach uses a 3D Hotelling transform to initialize an optimization search. Then, the fine scale feature-based registration is performed using a robust, non-linear least squares algorithm. The robustness of the multi-view registration system allows for accurate 3D reconstructions from sparse 2D image planes. Volume measurements from multi-view 3D reconstructions are found to be consistently and significantly more accurate than measurements from single view reconstructions. The volume error of multi-view reconstruction is measured to be less than 5% of the true volume. We show that volume reconstruction accuracy is a function of the total number of 2D image planes and the number of views for calibrated phantom. In clinical in-vivo cardiac experiments, we show that volume estimates of the left ventricle from multi-view reconstructions are found to be in better agreement with clinical measures than measures from single view reconstructions. Multi-view 3D reconstruction from sparse 2D freehand B-mode images leads to more accurate volume quantification compared to single view systems. The flexibility and low-cost of the proposed system allow for fine control of the image acquisition planes for optimal 3D reconstructions from multiple views.
System Design Verification for Closed Loop Control of Oxygenation With Concentrator Integration.
Gangidine, Matthew M; Blakeman, Thomas C; Branson, Richard D; Johannigman, Jay A
2016-05-01
Addition of an oxygen concentrator into a control loop furthers previous work in autonomous control of oxygenation. Software integrates concentrator and ventilator function from a single control point, ensuring maximum efficiency by placing a pulse of oxygen at the beginning of the breath. We sought to verify this system. In a test lung, fraction of inspired oxygen (FIO2) levels and additional data were monitored. Tests were run across a range of clinically relevant ventilator settings in volume control mode, for both continuous flow and pulse dose flow oxygenation. Results showed the oxygen concentrator could maintain maximum pulse output (192 mL) up to 16 breaths per minute. Functionality was verified across ranges of tidal volumes and respiratory rates, with and without positive end-expiratory pressure, in continuous flow and pulse dose modes. For a representative test at respiratory rate 16 breaths per minute, tidal volume 550 mL, without positive end-expiratory pressure, pulse dose oxygenation delivered peak FIO2 of 76.83 ± 1.41%, and continuous flow 47.81 ± 0.08%; pulse dose flow provided a higher FIO2 at all tested setting combinations compared to continuous flow (p < 0.001). These tests verify a system that provides closed loop control of oxygenation while integrating time-coordinated pulse-doses from an oxygen concentrator. This allows the most efficient use of resources in austere environments. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Volume Sensor Development Test. Series 5 - Multi-Compartment System
2005-12-30
while concurrently rejecting nuisance sources. The VSP system was also successfully integrated with the DD(X) Autonomic Fire Suppression System ( AFSS ...represents a functional prototype of the device-level layer of the envisioned DD(X) Flight I AFSS control system [24]. The system’s automated response to...present in the DD(X) Flight I design [24]. The VSP system was incorporated into the AFSS control system , replacing the fire and smoke detectors that were
NASA Technical Reports Server (NTRS)
Saveker, D. R. (Editor)
1973-01-01
The preliminary design of a satellite plus computer earth resources information system is proposed for potential uses in fire prevention and control in the wildland fire community. Suggested are satellite characteristics, sensor characteristics, discrimination algorithms, data communication techniques, data processing requirements, display characteristics, and costs in achieving the integrated wildland fire information system.
Advanced thermal control for spacecraft applications
NASA Astrophysics Data System (ADS)
Hardesty, Robert; Parker, Kelsey
2015-09-01
In optical systems just like any other space borne system, thermal control plays an important role. In fact, most advanced designs are plagued with volume constraints that further complicate the thermal control challenges for even the most experienced systems engineers. Peregrine will present advances in satellite thermal control based upon passive heat transfer technologies to dissipate large thermal loads. This will address the use of 700 W/m K and higher conducting products that are five times better than aluminum on a specific basis providing enabling thermal control while maintaining structural support.
Nimigan, André S; Gan, Bing Siang
2011-01-01
Purpose. Little attention has been given to syringe design and local anaesthetic administration methods. A microprocessor-controlled anaesthetic delivery device has become available that may minimize discomfort during injection. The purpose of this study was to document the pain experience associated with the use of this system and to compare it with use of a conventional syringe. Methods. A prospective, randomized clinical trial was designed. 40 patients undergoing carpal tunnel release were block randomized according to sex into a two groups: a traditional syringe group and a microprocessor-controlled device group. The primary outcome measure was surgical pain and local anaesthetic administration pain. Secondary outcomes included volume of anaesthetic used and injection time. Results. Analysis showed that equivalent anaesthesia was achieved in the microprocessor-controlled group despite using a significantly lower volume of local anaesthetic (P = .0002). This same group, however, has significantly longer injection times (P < .0001). Pain during the injection process or during surgery was not different between the two groups. Conclusions. This RCT comparing traditional and microprocessor controlled methods of administering local anaesthetic showed similar levels of discomfort in both groups. While the microprocessor-controlled group used less volume, the total time for the administration was significantly greater.
This report describes the technologies likely to be used for development of coal, oil shale, uranium, oil, natural gas, and geothermal resources in eight western states (Arizona, Colorado, Montana, New Mexico, North Dakota, South Dakota, Utah, and Wyoming). Volume 1 describes the...
Distributed Control Architecture for Gas Turbine Engine. Chapter 4
NASA Technical Reports Server (NTRS)
Culley, Dennis; Garg, Sanjay
2009-01-01
The transformation of engine control systems from centralized to distributed architecture is both necessary and enabling for future aeropropulsion applications. The continued growth of adaptive control applications and the trend to smaller, light weight cores is a counter influence on the weight and volume of control system hardware. A distributed engine control system using high temperature electronics and open systems communications will reverse the growing trend of control system weight ratio to total engine weight and also be a major factor in decreasing overall cost of ownership for aeropropulsion systems. The implementation of distributed engine control is not without significant challenges. There are the needs for high temperature electronics, development of simple, robust communications, and power supply for the on-board electronics.
Fuentes, Paola; Barrós-Loscertales, Alfonso; Bustamante, Juan Carlos; Rosell, Patricia; Costumero, Víctor; Ávila, César
2012-09-01
The Behavioral Inhibition System (BIS) is described in Gray's Reinforcement Sensitivity Theory as a hypothetical construct that mediates anxiety in animals and humans. The neuroanatomical correlates of this system are not fully clear, although they are known to involve the amygdala, the septohippocampal system, and the prefrontal cortex. Previous neuroimaging research has related individual differences in BIS with regional volume and functional variations in the prefrontal cortex, amygdala, and hippocampal formation. The aim of the present work was to study BIS-related individual differences and their relationship with brain regional volume. BIS sensitivity was assessed through the BIS/BAS questionnaire in a sample of male participants (N = 114), and the scores were correlated with brain regional volume in a voxel-based morphometry analysis. The results show a negative correlation between the BIS and the volume of the right and medial orbitofrontal cortices and the precuneus. Our results and previous findings suggest that individual differences in anxiety-related personality traits and their related psychopathology may be associated with reduced brain volume in certain structures relating to emotional control (i.e., the orbitofrontal cortex) and self-consciousness (i.e., the precuneus), as shown by our results.
Collision avoidance system cost-benefit analysis : volume III - appendices F-M
DOT National Transportation Integrated Search
1981-09-01
Collision-avoidance systems under development in the U.S.A., Japan and Germany were evaluated. The performance evaluation showed that the signal processing and the control law of a system were the key parameters that decided the system's capability, ...
Collision avoidance system cost-benefit analysis : volume II - appendices A-E
DOT National Transportation Integrated Search
1981-09-01
Collision-avoidance systems under development in the U.S.A., Japan and Germany were evaluated. The performance evaluation showed that the signal processing and the control law of a system were the key parameters that decided the system's capability, ...
Conceptual design and evaluation of selected Space Station concepts, volume 2
NASA Technical Reports Server (NTRS)
1983-01-01
The partially closed cycle environmental control and Life Support Subsystems is examined. Components of the system include air pressure control, heat control, water management, air and water quality monitors, fire detection and suppression, personnel escape, and EVA support subsystems.
METHODS FOR OPTIMIZING URBAN WET-WEATHER CONTROL SYSTEM
To minimize impacts of urban nonpoint source pollution and associated costs of control (storage and treatment) associated with wet-weather flows (WWFs), stormwater runoff volumes and pollutant loads must be reduced. A number of control strategies, so-called “best management pract...
NASA Technical Reports Server (NTRS)
Kawamura, K.; Beale, G. O.; Schaffer, J. D.; Hsieh, B. J.; Padalkar, S.; Rodriguez-Moscoso, J. J.
1985-01-01
A reference manual is provided for NESS, a simulation expert system. This manual gives user information regarding starting and operating NASA expert simulation system (NESS). This expert system provides an intelligent interface to a generic simulation program for spacecraft attitude control problems. A menu of the functions the system can perform is provided. Control repeated returns to this menu after executing each user request.
NASA Astrophysics Data System (ADS)
Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.
2015-11-01
This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.
Tick control: trapping, biocontrol, host management and other alternative strategies
Ginsberg, Howard S.; Edited by Sonenshine, Daniel E.; Roe, R. Michael
2014-01-01
Biology of Ticks is the most comprehensive work on tick biology and tick-borne diseases. This second edition is a multi-authored work, featuring the research and analyses of renowned experts across the globe. Spanning two volumes, the book examines the systematics, biology, structure, ecological adaptations, evolution, genomics and the molecular processes that underpin the growth, development and survival of these important disease-transmitting parasites. Also discussed is the remarkable array of diseases transmitted (or caused) by ticks, as well as modern methods for their control. This book should serve as a modern reference for students, scientists, physicians, veterinarians and other specialists. Volume I covers the biology of the tick and features chapters on tick systematics, tick life cycles, external and internal anatomy, and others dedicated to specific organ systems, specifically, the tick integument, mouthparts and digestive system, salivary glands, waste removal, salivary glands, respiratory system, circulatory system and hemolymph, fat body, the nervous and sensory systems and reproductive systems. Volume II includes chapters on the ecology of non-nidicolous and nidicolous ticks, genetics and genomics (including the genome of the Lyme disease vector Ixodes scapularis) and immunity, including host immune responses to tick feeding and tick-host interactions, as well as the tick's innate immune system that prevents and/or controls microbial infections. Six chapters cover in depth the many diseases caused by the major tick-borne pathogens, including tick-borne protozoa, viruses, rickettsiae of all types, other types of bacteria (e.g., the Lyme disease agent) and diseases related to tick paralytic agents and toxins. The remaining chapters are devoted to tick control using vaccines, acaricides, repellents, biocontrol, and, finally, techniques for breeding ticks in order to develop tick colonies for scientific study.
Limbic system structure volumes and associated neurocognitive functioning in former NFL players.
Lepage, Christian; Muehlmann, Marc; Tripodis, Yorghos; Hufschmidt, Jakob; Stamm, Julie; Green, Katie; Wrobel, Pawel; Schultz, Vivian; Weir, Isabelle; Alosco, Michael L; Baugh, Christine M; Fritts, Nathan G; Martin, Brett M; Chaisson, Christine; Coleman, Michael J; Lin, Alexander P; Pasternak, Ofer; Makris, Nikos; Stern, Robert A; Shenton, Martha E; Koerte, Inga K
2018-05-19
Chronic traumatic encephalopathy (CTE) is a neurodegenerative disease associated with exposure to repetitive head impacts. CTE has been linked to disruptions in cognition, mood, and behavior. Unfortunately, the diagnosis of CTE can only be made post-mortem. Neuropathological evidence suggests limbic structures may provide an opportunity to characterize CTE in the living. Using 3 T magnetic resonance imaging, we compared select limbic brain regional volumes - the amygdala, hippocampus, and cingulate gyrus - between symptomatic former National Football League (NFL) players (n = 86) and controls (n = 22). Moreover, within the group of former NFL players, we examined the relationship between those limbic structures and neurobehavioral functioning (n = 75). The former NFL group comprised eighty-six men (mean age = 55.2 ± 8.0 years) with at least 12 years of organized football experience, at least 2 years of active participation in the NFL, and self-reported declines in cognition, mood, and behavior within the last 6 months. The control group consisted of men (mean age = 57.0 ± 6.6 years) with no history of contact-sport involvement or traumatic brain injury. All control participants provided neurobehavioral data. Compared to controls, former NFL players exhibited reduced volumes of the amygdala, hippocampus, and cingulate gyrus. Within the NFL group, reduced bilateral cingulate gyrus volume was associated with worse attention and psychomotor speed (r = 0.4 (right), r = 0.42 (left); both p < 0.001), while decreased right hippocampal volume was associated with worse visual memory (r = 0.25, p = 0.027). Reduced volumes of limbic system structures in former NFL players are associated with neurocognitive features of CTE. Volume reductions in the amygdala, hippocampus, and cingulate gyrus may be potential biomarkers of neurodegeneration in those at risk for CTE.
The DTIC Review. Hybrid and Electronic Vehicles. Volume 4. Number 1, June 1998.
1998-06-01
ARGONNE NATIONAL LAB KIRTLAND AFB, NM IL (U) Constant-Thrust Orbit-Raising Transfer Charts. • (U) Dynamics and Controls in Maglev Systems DESCRIPTIVE...method to levitated ( MAGLEV ) ground transportation systems has generate minimum-fuel trajectories between coplanar important consequences for safety...satellite designers to control systems must be considered if MAGLEV systems assess preliminary fuel requirements for constant-thrust are to be economically
Intrinsic controls on the range of volumes, morphologies, and dimensions of submarine lobes
NASA Astrophysics Data System (ADS)
Prélat, A.; Covault, J. A.; Hodgson, D. M.; Fildani, A.; Flint, S. S.
2010-12-01
Submarine lobe dimensions from six different systems are compared: 1) the exhumed Permian Fan 3 lobe complex of the Tanqua Karoo, South Africa; 2) the modern Amazon fan channel-mouth lobe complex, offshore Brazil; 3) a portion of the modern distal Zaïre fan, offshore Angola/Congo; 4) a Pleistocene fan of the Kutai basin, subsurface offshore Indonesia; 5) the modern Golo system, offshore east Corsica, France; and 6) a shallow subsurface lobe complex , offshore Nigeria. These six systems have significantly different source-to-sink configurations (shelf dimension and slope topography), sediment supply characteristics (available grain size range and supply rate), tectonic settings, (palaeo) latitude, and delivery systems. Despite these differences, lobe deposits share similar geometric and dimensional characteristics. Lobes are grouped into two distinct populations of geometries that can be related to basin floor topography. The first population corresponds to areally extensive but thin lobes (average width 14 km × length 35 km × thickness 12 m) that were deposited onto low relief basin floor areas. Examples of such systems include the Tanqua Karoo, the Amazon, and the Zaïre systems. The second population corresponds to areally smaller but thicker lobes (average width 5 km × length 8 km × thickness 30 m) that were deposited into settings with higher amplitude of relief, like in the Corsican trough, the Kutai basin, and offshore Nigeria. The two populations of lobe types, however, share similar volumes (a narrow range around 1 or 2 km 3), which suggests that there is a control to the total volume of sediment that individual lobes can reach before they shift to a new locus of deposition. This indicates that the extrinsic processes control the number of lobes deposited per unit time rather than their dimensions. Two alternative hypotheses are presented to explain the similarities in lobe volumes calculated from the six very different systems. The first states that the wide range of starting flow volume and grain size across all systems enters the basin floor as a narrow range due to slope 'filtering' via more overspill and intra-channel deposition in larger systems. The second hypothesis is a result of the gradual decrease in downstream gradient from the distributive channel base to the lobe top during lobe growth. This is not sustainable as the channel will start to aggrade, and when a steeper lateral gradient is present, an avulsion will occur to an adjacent depositional low, which will be used for flows to fill and build a new lobe. This analysis of submarine lobe volumes indicates that the basin floor topography influences lobe geometry, but the fact that lobe volumes have a narrow range indicates a strong influence of intrinsic processes.
Intrinsic controls on the range of volumes, morphologies, and dimensions of submarine lobes
Prelat, A.; Covault, J.A.; Hodgson, D.M.; Fildani, A.; Flint, S.S.
2010-01-01
Submarine lobe dimensions from six different systems are compared: 1) the exhumed Permian Fan 3 lobe complex of the Tanqua Karoo, South Africa; 2) the modern Amazon fan channel-mouth lobe complex, offshore Brazil; 3) a portion of the modern distal Za??re fan, offshore Angola/Congo; 4) a Pleistocene fan of the Kutai basin, subsurface offshore Indonesia; 5) the modern Golo system, offshore east Corsica, France; and 6) a shallow subsurface lobe complex , offshore Nigeria. These six systems have significantly different source-to-sink configurations (shelf dimension and slope topography), sediment supply characteristics (available grain size range and supply rate), tectonic settings, (palaeo) latitude, and delivery systems. Despite these differences, lobe deposits share similar geometric and dimensional characteristics. Lobes are grouped into two distinct populations of geometries that can be related to basin floor topography. The first population corresponds to areally extensive but thin lobes (average width 14km??length 35km??thickness 12m) that were deposited onto low relief basin floor areas. Examples of such systems include the Tanqua Karoo, the Amazon, and the Za??re systems. The second population corresponds to areally smaller but thicker lobes (average width 5km??length 8km??thickness 30m) that were deposited into settings with higher amplitude of relief, like in the Corsican trough, the Kutai basin, and offshore Nigeria. The two populations of lobe types, however, share similar volumes (a narrow range around 1 or 2km3), which suggests that there is a control to the total volume of sediment that individual lobes can reach before they shift to a new locus of deposition. This indicates that the extrinsic processes control the number of lobes deposited per unit time rather than their dimensions. Two alternative hypotheses are presented to explain the similarities in lobe volumes calculated from the six very different systems. The first states that the wide range of starting flow volume and grain size across all systems enters the basin floor as a narrow range due to slope 'filtering' via more overspill and intra-channel deposition in larger systems. The second hypothesis is a result of the gradual decrease in downstream gradient from the distributive channel base to the lobe top during lobe growth. This is not sustainable as the channel will start to aggrade, and when a steeper lateral gradient is present, an avulsion will occur to an adjacent depositional low, which will be used for flows to fill and build a new lobe. This analysis of submarine lobe volumes indicates that the basin floor topography influences lobe geometry, but the fact that lobe volumes have a narrow range indicates a strong influence of intrinsic processes. ?? 2010 Elsevier B.V.
NASA Astrophysics Data System (ADS)
Jiang, Yu; Fletcher, John; Burr, Patrick; Hall, Charles; Zheng, Bowen; Wang, Da-Wei; Ouyang, Zi; Lennon, Alison
2018-04-01
Photovoltaic (PV) systems can exhibit rapid variances in their power output due to irradiance changes which can destabilise an electricity grid. This paper presents a quantitative comparison of the suitability of different electrochemical energy storage system (ESS) technologies to provide ramp-rate control of power in PV systems. Our investigations show that, for PV systems ranging from residential rooftop systems to megawatt power systems, lithium-ion batteries with high energy densities (up to 600 Wh L-1) require the smallest power-normalised volumes to achieve the ramp rate limit of 10% min-1 with 100% compliance. As the system size increases, the ESS power-normalised volume requirements are significantly reduced due to aggregated power smoothing, with high power lithium-ion batteries becoming increasingly more favourable with increased PV system size. The possibility of module-level ramp-rate control is also introduced, and results show that achievement of a ramp rate of 10% min-1 with 100% compliance with typical junction box sizes will require ESS energy and power densities of 400 Wh L-1 and 2300 W L-1, respectively. While module-level ramp-rate control can reduce the impact of solar intermittence, the requirement is challenging, especially given the need for low cost and long cycle life.
NASA Technical Reports Server (NTRS)
Hill, T. E.
1972-01-01
The design and development of the Tracking and Data Relay satellite are discussed. The subjects covered are: (1) spacecraft mechanical and structural design, (2) attitude stabilization and control subsystem, (3) propulsion system, (4) electrical power subsystem, (5) thermal control, and (6) reliability engineering.
A bioreactor system for the nitrogen loop in a Controlled Ecological Life Support System
NASA Technical Reports Server (NTRS)
Saulmon, M. M.; Reardon, K. F.; Sadeh, W. Z.
1996-01-01
As space missions become longer in duration, the need to recycle waste into useful compounds rises dramatically. This problem can be addressed by the development of Controlled Ecological Life Support Systems (CELSS) (i.e., Engineered Closed/Controlled Eco-Systems (ECCES)), consisting of human and plant modules. One of the waste streams leaving the human module is urine. In addition to the reclamation of water from urine, recovery of the nitrogen is important because it is an essential nutrient for the plant module. A 3-step biological process for the recycling of nitrogenous waste (urea) is proposed. A packed-bed bioreactor system for this purpose was modeled, and the issues of reaction step segregation, reactor type and volume, support particle size, and pressure drop were addressed. Based on minimization of volume, a bioreactor system consisting of a plug flow immobilized urease reactor, a completely mixed flow immobilized cell reactor to convert ammonia to nitrite, and a plug flow immobilized cell reactor to produce nitrate from nitrite is recommended. It is apparent that this 3-step bioprocess meets the requirements for space applications.
Volume of a laser-induced microjet
NASA Astrophysics Data System (ADS)
Kawamoto, Sennosuke; Hayasaka, Keisuke; Noguchi, Yuto; Tagawa, Yoshiyuki
2015-11-01
Needle-free injection systems are of great importance for medical treatments. In spite of their great potential, these systems are not commonly used. One of the common problems is strong pain caused by diffusion shape of the jet. To solve this problem, the usage of a high-speed highly-focused microjet as needle-free injection system is expected. It is thus crucial to control important indicators such as ejected volume of the jet for its safe application. We conduct experiments to reveal which parameter influences mostly the ejected volume. In the experiments, we use a glass tube of an inner diameter of 500 micro-meter, which is filled with the liquid. One end is connected to a syringe and the other end is opened. Radiating the pulse laser instantaneously vapors the liquid, followed by the generation of a shockwave. We find that the maximum volume of a laser-induced bubble is approximately proportional to the ejected volume. It is also found that the occurrence of cavitation does not affect the ejected volume while it changes the jet velocity.
Solar power satellite system definition study. Volume 7, phase 1: SPS and rectenna systems analyses
NASA Technical Reports Server (NTRS)
1979-01-01
A systems definition study of the solar power satellite systems is presented. The design and power distribution of the rectenna system is discussed. The communication subsystem and thermal control characteristics are described and a failure analysis performed on the systems is reported.
Heat recovery system employing a temperature controlled variable speed fan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, W.T.
1986-05-20
A heat recovery system is described for use in recovering heat from an industrial process producing a heated fluid comprising: a source of inlet air; a housing coupled to the source and including a heat exchanger; means for passing the heated fluid through the heat exchanger; the housing including means for moving a variable volume of air adjustable over a continuous range from the source through the heat exchanger; air discharge means communicating with the housing for discharging air which has passed through the heat exchanger; a control system including first temperature sensing means for sensing the discharge temperature ofmore » the discharge air moving through the discharge means and a control circuit coupled to the first temperature sensing means and to the moving means for varying the volume of air moved in response to the sensed discharge temperature to control the temperature of discharge air passing through the discharge means at a first predetermined value; and the control system including second temperature sensing means for sensing the temperature of the source of inlet air and valve means coupled to and controlled by the control circuit to cause liquid to bypass the heat exchanger when the inlet air temperature rises above a second predetermined value.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busch, J.F.; Warren, M.L.
1988-09-01
This paper describes an analysis of air conditioning performance under hot and humid tropical climate conditions appropriate to the Association of South East Asian Nations (ASEAN) countries. This region, with over 280 million people, has one of the fastest economic and energy consumption growth rates in the world. The work reported here is aimed at estimating the conservation potential derived from good design and control of air conditioning systems in commercial buildings. To test the performance of different air conditioning system types and control options, whole building energy performance was simulated using DOE-2. The 5100 m/sup 2/ (50,000 ft/sup 2/)more » prototype office building module was previously used in earlier commercial building energy standards analysis for Malaysia and Singapore. In general, the weather pattern for ASEAN countries is uniform, with hot and humid air masses known as ''monsoons'' dictating the weather patterns. Since a concentration of cities occurs near the tip of the Malay peninsula, hourly temperature, humidity, and wind speed data for Kuala Lumpur was used for the analysis. Because of the absence of heating loads in ASEAN regions, we have limited air conditioning configurations to two pipe fan coil, constant volume, variable air volume, powered induction, and ceiling bypass configurations. Control strategies were varied to determine the conservation potential in both energy use and peak electric power demands. Sensitivities including fan control, pre-cooling and night ventilation, supply air temperature control, zone temperature set point, ventilation and infiltration, daylighting and internal gains, and system sizing were examined and compared with a base case which was a variable air volume system with no reheat or economizer. Comfort issues, such as over-cooling and space humidity, were also examined.« less
NASA Technical Reports Server (NTRS)
Knox, J.
1986-01-01
A higher plant growth system for Controlled Ecological Life Support System (CELSS) applications is described. The system permits independent movement of individual plants during growth. Enclosed within variable geometry growth chambers, the system allocates only the volume required by the growing plants. This variable spacing system maintains isolation between root and shoot environments, providing individual control for optimal growth. The advantages of the system for hydroponic and aeroponic growth chambers are discussed. Two applications are presented: (1) the growth of soybeans in a space station common module, and (2) in a terrestrial city greenhouse.
Long Range Plan for Embedded Computer Systems Support. Volume II
1981-10-01
interface (pilot displays and controls plus visual system), and data collection (CMAC data, bus data and simulation data). Non-real time functions include...unless adequate upfront planning is implemented, the command will be controlled by the dynamics rather than controll - ing them. The upfront planning should...or should they be called manually? What amount and type of data should the various tools pass between each other? Under what conditions and controls
Military Operations Research. Winter 1996. Volume 1, Number 4
1996-01-01
ANALYSIS DISTURBANCE INPUT OUTPUT PLANT SEMANTIC CONTROL SYSTEM CONTROL DESIGNER CONTROL I i LAW SYSTEM GOAL CONTROL IIDENTIFIER SELECTOR ADAPTER CONTRO...analysts for many years. It is designed to provide a quick reference for models that represent the effects of a conventional attack against ground...satellites offer this capability. This poses the additional challenge as to how many highways one can "see" per unit time. He did, however, design a
Werner, Herbert; Fabian, Peter
2002-01-01
A novel system for continuous and controlled free-air fumigation of mature tree canopies with ozone is described. Ozone generated from oxygen is diluted with air in a pressurized tank and conducted into the canopies by a system of 100 PTFE tubes hanging down from a grid fixed above the crowns. With 45 calibrated outlets per tube providing a constant flow of 0.3 l/min each, a total volume of about 10*10*15 m3 comprising 5 beech and 5 spruce canopies is fumigated. The spatial ozone distribution in the fumigated volume as well as surrounding reference tree canopies is controlled by continuous measuring instruments installed at 4 levels and a dense array of passive samplers. The system will later be used for CO2 fumigation as well. Results of the first year of continuous operation, with 2 * ambient ozone levels having been achieved, are reported.
Construction and Start-up of a Large-Volume Thermostat for Dielectric-Constant Gas Thermometry
NASA Astrophysics Data System (ADS)
Merlone, A.; Moro, F.; Zandt, T.; Gaiser, C.; Fellmuth, B.
2010-07-01
A liquid-bath thermostat with a volume of about 800 L was designed to provide a suitable thermal environment for a dielectric-constant gas thermometer (DCGT) in the range from the triple point of mercury to the melting point of gallium. In the article, results obtained with the unique, huge thermostat without the DCGT measuring chamber are reported to demonstrate the capability of controlling the temperature of very large systems at a metrological level. First tests showed that the bath together with its temperature controller provide a temperature variation of less than ±0.5mK peak-to-peak. This temperature instability could be maintained over a period of several days. In the central working volume (diameter—500mm, height—650mm), in which the vacuum chamber containing the measuring system of the DCGT will be placed later, the temperature inhomogeneity has been demonstrated to be also well below 1mK.
Magmatic densities control erupted volumes in Icelandic volcanic systems
NASA Astrophysics Data System (ADS)
Hartley, Margaret; Maclennan, John
2018-04-01
Magmatic density and viscosity exert fundamental controls on the eruptibility of magmas. In this study, we investigate the extent to which magmatic physical properties control the eruptibility of magmas from Iceland's Northern Volcanic Zone (NVZ). By studying subaerial flows of known age and volume, we are able to directly relate erupted volumes to magmatic physical properties, a task that has been near-impossible when dealing with submarine samples dredged from mid-ocean ridges. We find a strong correlation between magmatic density and observed erupted volumes on the NVZ. Over 85% of the total volume of erupted material lies close to a density and viscosity minimum that corresponds to the composition of basalts at the arrival of plagioclase on the liquidus. These magmas are buoyant with respect to the Icelandic upper crust. However, a number of small-volume eruptions with densities greater than typical Icelandic upper crust are also found in Iceland's neovolcanic zones. We use a simple numerical model to demonstrate that the eruption of magmas with higher densities and viscosities is facilitated by the generation of overpressure in magma chambers in the lower crust and uppermost mantle. This conclusion is in agreement with petrological constraints on the depths of crystallisation under Iceland.
Dalwani, Manish S; McMahon, Mary Agnes; Mikulich-Gilbertson, Susan K; Young, Susan E; Regner, Michael F; Raymond, Kristen M; McWilliams, Shannon K; Banich, Marie T; Tanabe, Jody L; Crowley, Thomas J; Sakai, Joseph T
2015-01-01
Structural neuroimaging studies have demonstrated lower regional gray matter volume in adolescents with severe substance and conduct problems. These research studies, including ours, have generally focused on male-only or mixed-sex samples of adolescents with conduct and/or substance problems. Here we compare gray matter volume between female adolescents with severe substance and conduct problems and female healthy controls of similar ages. Female adolescents with severe substance and conduct problems will show significantly less gray matter volume in frontal regions critical to inhibition (i.e. dorsolateral prefrontal cortex and ventrolateral prefrontal cortex), conflict processing (i.e., anterior cingulate), valuation of expected outcomes (i.e., medial orbitofrontal cortex) and the dopamine reward system (i.e. striatum). We conducted whole-brain voxel-based morphometric comparison of structural MR images of 22 patients (14-18 years) with severe substance and conduct problems and 21 controls of similar age using statistical parametric mapping (SPM) and voxel-based morphometric (VBM8) toolbox. We tested group differences in regional gray matter volume with analyses of covariance, adjusting for age and IQ at p<0.05, corrected for multiple comparisons at whole-brain cluster-level threshold. Female adolescents with severe substance and conduct problems compared to controls showed significantly less gray matter volume in right dorsolateral prefrontal cortex, left ventrolateral prefrontal cortex, medial orbitofrontal cortex, anterior cingulate, bilateral somatosensory cortex, left supramarginal gyrus, and bilateral angular gyrus. Considering the entire brain, patients had 9.5% less overall gray matter volume compared to controls. Female adolescents with severe substance and conduct problems in comparison to similarly aged female healthy controls showed substantially lower gray matter volume in brain regions involved in inhibition, conflict processing, valuation of outcomes, decision-making, reward, risk-taking, and rule-breaking antisocial behavior.
The study on servo-control system in the large aperture telescope
NASA Astrophysics Data System (ADS)
Hu, Wei; Zhenchao, Zhang; Daxing, Wang
2008-08-01
Large astronomical telescope or extremely enormous astronomical telescope servo tracking technique will be one of crucial technology that must be solved in researching and manufacturing. To control technique feature of large astronomical telescope or extremely enormous astronomical telescope, this paper design a sort of large astronomical telescope servo tracking control system. This system composes a principal and subordinate distributed control system, host computer sends steering instruction and receive slave computer functional mode, slave computer accomplish control algorithm and execute real-time control. Large astronomical telescope servo control use direct drive machine, and adopt DSP technology to complete direct torque control algorithm, Such design can not only increase control system performance, but also greatly reduced volume and costs of control system, which has a significant occurrence. The system design scheme can be proved reasonably by calculating and simulating. This system can be applied to large astronomical telescope.
Soviet Cybernetics Review. Volume 2, Number 5,
prize; Aeroflot’s sirena system turned on; Computer system controls 2500 construction sites; Automation of aircraft languages; Diagnosis by teletype; ALGEM-1 and ALGEM-2 languages; Nuclear institute’s computer facilities.
NASA Technical Reports Server (NTRS)
Bodley, C. S.; Devers, A. D.; Park, A. C.; Frisch, H. P.
1978-01-01
A theoretical development and associated digital computer program system for the dynamic simulation and stability analysis of passive and actively controlled spacecraft are presented. The dynamic system (spacecraft) is modeled as an assembly of rigid and/or flexible bodies not necessarily in a topological tree configuration. The computer program system is used to investigate total system dynamic characteristics, including interaction effects between rigid and/or flexible bodies, control systems, and a wide range of environmental loadings. In addition, the program system is used for designing attitude control systems and for evaluating total dynamic system performance, including time domain response and frequency domain stability analyses.
Concept for a Satellite-Based Advanced Air Traffic Management System : Volume 1. Summary.
DOT National Transportation Integrated Search
1974-02-01
The report contains the results of studies and analyses directed toward the definition of a Satellite-Based Advanced Air Traffic Management System (SAATMS). This system is an advanced, integrated air traffic control system which is based on the use o...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-01-01
Literature summarizing a study on the Saudi Arabian solar controlled environment agriculture system is presented. Specifications and performance requirements for the system components are revealed. Detailed performance and cost analyses are used to determine the optimum design. A preliminary design of an engineering field test is included. Some weather data are provided for Riyadh, Saudi Arabia. (BCS)
Thermal Battery Operating Gas Atmosphere Control and Heat Transfer Optimization
2012-09-01
volume of water vapor present at 21.8 C in sample bottles std atm cc 1.533645 Maximum volume of water vapor present at 21.8 C in gas handling system and...sample bottles std atm cc Comparison of gas volumes measured at 838.197 and 1682.297 seconds shows that no water vapor was present and that the gas reacted...temperature of 22.0 ºC torr 0.241556 Maximum volume of water vapor present in one sample bottle std atm cc 0.000194 Maximum weight of water vapor present
Display And Analysis Of Tomographic Volumetric Images Utilizing A Vari-Focal Mirror
NASA Astrophysics Data System (ADS)
Harris, L. D.; Camp, J. J.
1984-10-01
A system for the three-dimensional (3-D) display and analysis of stacks of tomographic images is described. The device utilizes the principle of a variable focal (vari-focal) length optical element in the form of an aluminized membrane stretched over a loudspeaker to generate a virtual 3-D image which is a visible representation of a 3-D array of image elements (voxels). The system displays 500,000 voxels per mirror cycle in a 3-D raster which appears continuous and demonstrates no distracting artifacts. The display is bright enough so that portions of the image can be dimmed without compromising the number of shades of gray. For x-ray CT, a displayed volume image looks like a 3-D radiograph which appears to be in the space directly behind the mirror. The viewer sees new views by moving his/her head from side to side or up and down. The system facilitates a variety of operator interactive functions which allow the user to point at objects within the image, control the orientation and location of brightened oblique planes within the volume, numerically dissect away selected image regions, and control intensity window levels. Photographs of example volume images displayed on the system illustrate, to the degree possible in a flat picture, the nature of displayed images and the capabilities of the system. Preliminary application of the display device to the analysis of volume reconstructions obtained from the Dynamic Spatial Reconstructor indicates significant utility of the system in selecting oblique sections and gaining an appreciation of the shape and dimensions of complex organ systems.
High-throughput controllable generation of droplet arrays with low consumption
NASA Astrophysics Data System (ADS)
Lin, Yinyin; Wu, Zhongsheng; Gao, Yibo; Wu, Jinbo; Wen, Weijia
2018-06-01
We describe a controllable sliding method for fabricating millions of isolated femto- to nanoliter-sized droplets with defined volume, geometry and position and a speed of up to 375 kHz. In this work, without using a superhydrophobic or superoleophobic surface, arrays of droplets are instantly formed on the patterned substrate by sliding a strip of liquid, including water, low-surface-tension organic solvents and solution, along the substrate. To precisely control the volume of the droplets, we systemically investigate the effects of the size of the wettable pattern, the viscosity of the liquid and sliding speed, which were found to vary independently to tune the height and volume of the droplets. Through this method, we successfully fabricated an oriented single metal-organic framework crystal array with control over their XY positioning on the surface, as characterized by microscopy and X-ray diffraction (XRD) techniques.
Friedman, Avner; Lachowicz, Mirosław; Ledzewicz, Urszula; Piotrowska, Monika Joanna; Szymanska, Zuzanna
2017-02-01
This volume was inspired by the topics presented at the international conference "Micro and Macro Systems in Life Sciences" which was held on Jun 8-12, 2015 in Będlewo, Poland. System biology is an approach which tries to understand how micro systems, at the molecular and cellular levels, affect macro systems such as organs, tissue and populations. Thus it is not surprising that a major theme of this volume evolves around cancer and its treatment. Articles on this topic include models for tumor induced angiogenesis, without and with delays, metastatic niche of the bone marrow, drug resistance and metronomic chemotherapy, and virotherapy of glioma. Methods range from dynamical systems to optimal control. Another well represented topic of this volume is mathematical modeling in epidemiology. Mathematical approaches to modeling and control of more specific diseases like malaria, Ebola or human papillomavirus are discussed as well as a more general approaches to the SEIR, and even more general class of models in epidemiology, by using the tools of optimal control and optimization. The volume also brings up challenges in mathematical modeling of other diseases such as tuberculosis. Partial differential equations combined with numerical approaches are becoming important tools in modeling not only tumor growth and treatment, but also other diseases, such as fibrosis of the liver, and atherosclerosis and its associated blood flow dynamics, and our volume presents a state of the art approach on these topics. Understanding mathematics behind the cell motion, appearance of the special patterns in various cell populations, and age structured mutations are among topics addressed inour volume. A spatio-temporal models of synthetic genetic oscillators brings the analysis to the gene level which is the focus of much of current biological research. Mathematics can help biologists to explain the collective behavior of bacterial, a topic that is also presented here. Finally some more across the discipline topics are being addresses, which can appear as a challenge in studying problems in systems biology on all, macro, meso and micro levels. They include numerical approaches to stochastic wave equation arising in modeling Brownian motion, discrete velocity models, many particle approximations as well as very important aspect on the connection between discrete measurement and the construction of the models for various phenomena, particularly the one involving delays. With the variety of biological topics and their mathematical approaches we very much hope that the reader of the Mathematical Biosciences and Engineering will find this volume interesting and inspirational for their own research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, E.R.
1983-09-01
This volume on specifications for the Saguaro Power Plant includes the following: subsystem interface definition document; solar collector subsystem specification; receiver specification; thermal energy storage specification; solar steam generator specification; and master control system specification.
Respiratory system loop gain in normal men and women measured with proportional-assist ventilation.
Wellman, Andrew; Malhotra, Atul; Fogel, Robert B; Edwards, Jill K; Schory, Karen; White, David P
2003-01-01
We hypothesized that increased chemical control instability (CCI) in men could partially explain the male predominance in obstructive sleep apnea (OSA). CCI was assessed by sequentially increasing respiratory control system loop gain (LG) with proportional-assist ventilation (PAV) in 10 men (age 24-48 yr) and 9 women (age 22-36 yr) until periodic breathing or awakening occurred. Women were studied in both the follicular and luteal phases of the menstrual cycle. The amount by which PAV amplified LG was quantified from the tidal volume amplification factor [(VtAF) assisted tidal volume/unassisted tidal volume]. LG was calculated as the inverse of the VtAF occurring at the assist level immediately preceding the emergence of periodic breathing (when LG x VtAF = 1). Only 1 of 10 men and 2 of 9 women developed periodic breathing with PAV. The rest were resistant to periodic breathing despite moderately high levels of PAV amplification. We conclude that LG is low in the majority of normal men and women and that higher volume amplification factors are needed to determine whether gender differences exist in this low range.
Fundamentals of SCADA and automated meter reading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwok, A.
1992-02-01
This paper discusses SCADA systems allow users to control and acquire data from remote facilities such as compressors, pressure-regulating stations, control valves and measurement stations. In general, a SCADA system performs functions in sequential control, continuous control, supervisory setpoint control and data acquisitions. AMR systems allow users to obtain up-to-date information on their gas demand. When AMR was in its infancy, equipment was designed only to read and record gas consumption values. The basic function of an early AMR system was to read gas volume at a fixed interval and record the data in its memory until it communicated withmore » a central receiving facility.« less
1978-04-15
analyst who is concerned with preparing the data base for a war game, selecting optional features of QUICK, designating control parameters, submitting...i/.,-j-t r? 70 ~ CoMPUIfE YsTIEM MANUAL CSM UM 9-77 VOLUME IIIC15 APRIL 1978 Lod COMMAND 9 \\.., & CONTROL 09 TECHNICAL . CENTER CCTC QUICK-REACTING...RECALC Mode ............................... 31 3.1.1.2 Non -RECALC Mode ........................... 31 3.1.1.3 Mode Selecti-n and JCL Consideration
The Aerothermodynamics of Aircraft Gas Turbine Engines
1978-07-01
engine will deteriorate. 1.6.2 Experimental Testing It is easy to fall int9 the organiza- tional trap of four isolated groups . One group does the... Quasi -Dne-Dimensional Fluid Flows The First Law for a F1mdng System-- The Control Volume • . • The Channel Flow Equations Stagnation Properties...exit to control volume (Eq • 2. 14 . 2) CHAPTER TWO THERMODYNAMICS AND QUASI -ONE-DUlENSIONAL FLUID FLO’’{S 2.0 INTRODUCTION This chapter "ill be
1991-07-31
INTELLIGENT SCSI DMV-719 MAS MIL CONTROLLER DY-4 SYSTEMS BYTE-WIDE MEMORY CARD DMV-536 MEM MIL DY-4 SYSTEMS POWER SUPPLY UNIT DMV-870 PWR MIL P age No. 5 06/10...FORCE COMPUTERS PROCESSOR CPU-386 SERIES SBC COM FORCE COMPUTERS ADVANCED SYSTEM CONTROL ASCU -1/2 SBC COM UNITI FORCE COMPUTERS GRAPHICS CONTROLLER AGC...RECORD VENDOR: JANZ COMPUTER AG DIVISION: VENDOR ADDRESS: Im Doerener Feld 3 D-4790 Paderborn Germany MARKETING: Johannes Kunz TECHNICAL: Arnulf
1983-06-01
LOSARDO Project Engineer APPROVED: .MARMCINIhI, Colonel. USAF Chief, Coaud and Control Division FOR THE CCOaIDKR: Acting Chief, Plea Off ice * **711...WORK UNIT NUMBERS General Dynamics Corporation 62702F Data Systems Division P 0 Box 748, Fort Worth TX 76101 55811829 I1. CONTROLLING OFFICE NAME AND...Processing System for 29 the Operation/Direction Center(s) 4-3 Distribution of Processing Control 30 for the Operation/Direction Center(s) 4-4 Generalized
Total Quality Management Guide. Volume 2. A Guide to Implementation
1990-02-15
Kaoru . Guide to Quality Control. Asian Productivity Organization. 1984. Ishikawa , Kaoru . What is Total Quality Control? The Japanese Way. Englewood...of the new Systems Age. The theories of Deming, Juran, Ishikawa , and other management methods that still predominate are pioneers of Systems Age...Feigenbaum, Armand V. Total Quality Control. New York: McGraw-Hill Book Company. 1983. bnai, Masaaki. Kaizen. New York: Random House. 1986. Ishikawa
Shuttle mission simulator requirements report, volume 1, revision A
NASA Technical Reports Server (NTRS)
Burke, J. F.
1973-01-01
The tasks are defined required to design, develop produce, and field support a shuttle mission simulator for training crew members and ground support personnel. The requirements for program management, control, systems engineering, design and development are discussed along with the design and construction standards, software design, control and display, communication and tracking, and systems integration.
1978-06-01
and Sound Levels. Tank sound characteris- tics can be categorized by four areas of tank operation. These are: engine starting and running, mobility or...the use of the ballistic computer system. The indirect sighting and fire control system consists of the elevation quadrant M13A3, a control light source...in low ambient 2-22 temperatures. No controls or indicators are provided for the engine air intake system. The exhaust system has four engine
NASA Technical Reports Server (NTRS)
1982-01-01
The integrated application of active controls (IAAC) technology to an advanced subsonic transport is reported. Supplementary technical data on the following topics are included: (1) 1990's avionics technology assessment; (2) function criticality assessment; (3) flight deck system for total control and functional features list; (4) criticality and reliability assessment of units; (5) crew procedural function task analysis; and (6) recommendations for simulation mechanization.
Sniffin' Sticks and olfactory system imaging in patients with Kallmann syndrome.
Ottaviano, Giancarlo; Cantone, Elena; D'Errico, Arianna; Salvalaggio, Alessandro; Citton, Valentina; Scarpa, Bruno; Favaro, Angela; Sinisi, Antonio Agostino; Liuzzi, Raffaele; Bonanni, Guglielmo; Di Salle, Francesco; Elefante, Andrea; Manara, Renzo; Staffieri, Alberto; Martini, Alessandro; Brunetti, Arturo
2015-09-01
The relationship between olfactory function, rhinencephalon and forebrain changes in Kallmann syndrome (KS) have not been adequately investigated. We evaluated a large cohort of male KS patients using Sniffin' Sticks and MRI in order to study olfactory bulb (OB) volume, olfactory sulcus (OS) depth, cortical thickness close to the OS, and olfactory phenotype. Olfaction was assessed administering Sniffin' Sticks®, in 38 KS patients and 17 controls (by means of Screening 12 test®). All subjects underwent magnetic resonance imaging (MRI) to study OB volume, sulcus depth, and cortical thickness. Compared to controls, KS patients showed smaller OB volume (p<0.0001), reduced sulcus depth (p<0.0001), and thicker cortex in the region close to the OS (p<0.0001). Anosmic KS patients had smaller OB than controls and hyposmic KS patients; there was no difference between hyposmic KS patients and controls. OB volume correlated with Sniffin' Sticks score (r = 0.64; p < 0.001), OS depth (p<0.0001) and, inversely, with cortical thickness changes (p<0.0001). Sniffin' Sticks showed an inverse correlation with cortical thickness (r = -0.5; p<0.0001) and a trend toward a statistically significant correlation with OS depth. The present study provides further evidence of the strict relationship between olfaction and OB volume. The strong correlation between OB volume and the overlying cortical changes highlights the key role of rhinencephalon in forebrain embryogenesis. © 2015 ARS-AAOA, LLC.
Decision support system in an international-voice-services business company
NASA Astrophysics Data System (ADS)
Hadianti, R.; Uttunggadewa, S.; Syamsuddin, M.; Soewono, E.
2017-01-01
We consider a problem facing by an international telecommunication services company in maximizing its profit. From voice services by controlling cost and business partnership. The competitiveness in this industry is very high, so that any efficiency from controlling cost and business partnership can help the company to survive in the very high competitiveness situation. The company trades voice traffic with a large number of business partners. There are four trading schemes that can be chosen by this company, namely, flat rate, class tiering, volume commitment, and revenue capped. Each scheme has a specific characteristic on the rate and volume deal, where the last three schemes are regarded as strategic schemes to be offered to business partner to ensure incoming traffic volume for both parties. This company and each business partner need to choose an optimal agreement in a certain period of time that can maximize the company’s profit. In this agreement, both parties agree to use a certain trading scheme, rate and rate/volume/revenue deal. A decision support system is then needed in order to give a comprehensive information to the sales officers to deal with the business partners. This paper discusses the mathematical model of the optimal decision for incoming traffic volume control, which is a part of the analysis needed to build the decision support system. The mathematical model is built by first performing data analysis to see how elastic the incoming traffic volume is. As the level of elasticity is obtained, we then derive a mathematical modelling that can simulate the impact of any decision on trading to the revenue of the company. The optimal decision can be obtained from these simulations results. To evaluate the performance of the proposed method we implement our decision model to the historical data. A software tool incorporating our methodology is currently in construction.
Volumetric calculation using low cost unmanned aerial vehicle (UAV) approach
NASA Astrophysics Data System (ADS)
Rahman, A. A. Ab; Maulud, K. N. Abdul; Mohd, F. A.; Jaafar, O.; Tahar, K. N.
2017-12-01
Unmanned Aerial Vehicles (UAV) technology has evolved dramatically in the 21st century. It is used by both military and general public for recreational purposes and mapping work. Operating cost for UAV is much cheaper compared to that of normal aircraft and it does not require a large work space. The UAV systems have similar functions with the LIDAR and satellite images technologies. These systems require a huge cost, labour and time consumption to produce elevation and dimension data. Measurement of difficult objects such as water tank can also be done by using UAV. The purpose of this paper is to show the capability of UAV to compute the volume of water tank based on a different number of images and control points. The results were compared with the actual volume of the tank to validate the measurement. In this study, the image acquisition was done using Phantom 3 Professional, which is a low cost UAV. The analysis in this study is based on different volume computations using two and four control points with variety set of UAV images. The results show that more images will provide a better quality measurement. With 95 images and four GCP, the error percentage to the actual volume is about 5%. Four controls are enough to get good results but more images are needed, estimated about 115 until 220 images. All in all, it can be concluded that the low cost UAV has a potential to be used for volume of water and dimension measurement.
Fourth Coast-Seaway Systems Requirements Analysis : Volume II
DOT National Transportation Integrated Search
1972-03-01
This report summarizes the need for an Integrated Marine Traffic Information and Control System (IMTIC) in the St. Lawrence Seaway. The analytic emphasis is on the Welland Canal to Gulf of St. Lawrence portion of the Seaway system. The Upper Great La...
Modeling the Hydrologic Processes of a Permeable Pavement System
A permeable pavement system can capture stormwater to reduce runoff volume and flow rate, improve onsite groundwater recharge, and enhance pollutant controls within the site. A new unit process model for evaluating the hydrologic performance of a permeable pavement system has be...
NASA Technical Reports Server (NTRS)
Heidergott, K. W.
1979-01-01
The computer program known as QR is described. Classical control systems analysis and synthesis (root locus, time response, and frequency response) can be performed using this program. Programming details of the QR program are presented.
Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display.
Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi
2016-08-16
This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human-computer interactions, advertising, and entertainment.
Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display
NASA Astrophysics Data System (ADS)
Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi
2016-08-01
This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human-computer interactions, advertising, and entertainment.
Collision Avoidance, Driver Support and Safety Intervention Systems
NASA Astrophysics Data System (ADS)
Gilling, Simon P.
Autonomous Intelligent Cruise Control (AICC) will be marketed by a number of vehicle manufacturers before the end of the decade. This paper will describe AICC and the next generation systems currently being developed and validated within the EC Fourth Framework project, Anti-Collision Autonomous Support and Safety Intervention SysTem (AC ASSIST).The currently available cruise control systems which maintain a fixed speed are a well-known form of longitudinal driver support. The fixed speed cruise control becomes less useful with increased traffic volumes, as the driver must disable the system when a slower preceding vehicle is encountered.
Some Applications of Piece-Wise Smooth Dynamical Systems
NASA Astrophysics Data System (ADS)
Janovská, Drahoslava; Hanus, Tomáš; Biák, Martin
2010-09-01
The Filippov systems theory is applied to selected problems from biology and chemical engineering, namely we explore and simulate Bazykin's ecological model, an ideal closed gas-liquid system including its dimensionless formulation. The last investigated system is a CSTR with an outfall and the CSTR with a reactor volume control.
DOT National Transportation Integrated Search
1979-11-01
The questions of expandability and modifiability of a 1990-era Air Traffic Control (ATC) system are addressed. Two strawman systems are described at the functional level: a Baseline System, which represents the ATC system as it might be just after th...
Transaction-based building controls framework, Volume 2: Platform descriptive model and requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akyol, Bora A.; Haack, Jereme N.; Carpenter, Brandon J.
Transaction-based Building Controls (TBC) offer a control systems platform that provides an agent execution environment that meets the growing requirements for security, resource utilization, and reliability. This report outlines the requirements for a platform to meet these needs and describes an illustrative/exemplary implementation.
Shuttle mission simulator requirement report, volume 2, revision A
NASA Technical Reports Server (NTRS)
Burke, J. F.
1973-01-01
The training requirements of all mission phases for crews and ground support personnel are presented. The specifications are given for the design and development of the simulator, data processing systems, engine control, software, and systems integration.
Liquid and gaseous oxygen safety review, volume 1
NASA Technical Reports Server (NTRS)
Lapin, A.
1972-01-01
Materials used or contained in liquid and gaseous oxygen systems are analyzed for their compatibility; and areas of possible concern in oxygen systems are outlined. Design criteria, cleaning procedures, and quality control methods are covered in detail.
Inductive Interference in Rapid Transit Signaling Systems. Volume 3. Data and Test Results.
DOT National Transportation Integrated Search
1986-11-01
This report presents comparative inductive interference data obtained from four U.S. rapid transit systems employing chopper propulsion control, as part of the Rail Transit Electromagnetic Interference/Electromagnetic Compatibility program conducted ...
Winter Simulation Conference, Miami Beach, Fla., December 4-6, 1978, Proceedings. Volumes 1 & 2
NASA Technical Reports Server (NTRS)
Highland, H. J. (Editor); Nielsen, N. R.; Hull, L. G.
1978-01-01
The papers report on the various aspects of simulation such as random variate generation, simulation optimization, ranking and selection of alternatives, model management, documentation, data bases, and instructional methods. Simulation studies in a wide variety of fields are described, including system design and scheduling, government and social systems, agriculture, computer systems, the military, transportation, corporate planning, ecosystems, health care, manufacturing and industrial systems, computer networks, education, energy, production planning and control, financial models, behavioral models, information systems, and inventory control.
NASA Astrophysics Data System (ADS)
Pavlov, S. S.; Dmitriev, A. Yu.; Chepurchenko, I. A.; Frontasyeva, M. V.
2014-11-01
The automation system for measurement of induced activity of gamma-ray spectra for multi-element high volume neutron activation analysis (NAA) was designed, developed and implemented at the reactor IBR-2 at the Frank Laboratory of Neutron Physics. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis of linear positioning module M202A by DriveSet company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database.
Sharifi, N; Ozgoli, S; Ramezani, A
2017-06-01
Mixed immunotherapy and chemotherapy of tumours is one of the most efficient ways to improve cancer treatment strategies. However, it is important to 'design' an effective treatment programme which can optimize the ways of combining immunotherapy and chemotherapy to diminish their imminent side effects. Control engineering techniques could be used for this. The method of multiple model predictive controller (MMPC) is applied to the modified Stepanova model to induce the best combination of drugs scheduling under a better health criteria profile. The proposed MMPC is a feedback scheme that can perform global optimization for both tumour volume and immune competent cell density by performing multiple constraints. Although current studies usually assume that immunotherapy has no side effect, this paper presents a new method of mixed drug administration by employing MMPC, which implements several constraints for chemotherapy and immunotherapy by considering both drug toxicity and autoimmune. With designed controller we need maximum 57% and 28% of full dosage of drugs for chemotherapy and immunotherapy in some instances, respectively. Therefore, through the proposed controller less dosage of drugs are needed, which contribute to suitable results with a perceptible reduction in medicine side effects. It is observed that in the presence of MMPC, the amount of required drugs is minimized, while the tumour volume is reduced. The efficiency of the presented method has been illustrated through simulations, as the system from an initial condition in the malignant region of the state space (macroscopic tumour volume) transfers into the benign region (microscopic tumour volume) in which the immune system can control tumour growth. Copyright © 2017 Elsevier B.V. All rights reserved.
Interactive simulation system for artificial ventilation on the internet: virtual ventilator.
Takeuchi, Akihiro; Abe, Tadashi; Hirose, Minoru; Kamioka, Koichi; Hamada, Atsushi; Ikeda, Noriaki
2004-12-01
To develop an interactive simulation system "virtual ventilator" that demonstrates the dynamics of pressure and flow in the respiratory system under the combination of spontaneous breathing, ventilation modes, and ventilator options. The simulation system was designed to be used by unexperienced health care professionals as a self-training tool. The system consists of a simulation controller and three modules: respiratory, spontaneous breath, and ventilator. The respiratory module models the respiratory system by three resistances representing the main airway, the right and left lungs, and two compliances also representing the right and left lungs. The spontaneous breath module generates inspiratory negative pressure produced by a patient. The ventilator module generates driving force of pressure or flow according to the combination of the ventilation mode and options. These forces are given to the respiratory module through the simulation controller. The simulation system was developed using HTML, VBScript (3000 lines, 100 kB) and ActiveX control (120 kB), and runs on Internet Explorer (5.5 or higher). The spontaneous breath is defined by a frequency, amplitude and inspiratory patterns in the spontaneous breath module. The user can construct a ventilation mode by setting a control variable, phase variables (trigger, limit, and cycle), and options. Available ventilation modes are: controlled mechanical ventilation (CMV), continuous positive airway pressure, synchronized intermittent mandatory ventilation (SIMV), pressure support ventilation (PSV), SIMV + PSV, pressure-controlled ventilation (PCV), pressure-regulated volume control (PRVC), proportional assisted ventilation, mandatory minute ventilation (MMV), bilevel positive airway pressure (BiPAP). The simulation system demonstrates in a graph and animation the airway pressure, flow, and volume of the respiratory system during mechanical ventilation both with and without spontaneous breathing. We developed a web application that demonstrated the respiratory mechanics and the basic theory of ventilation mode.
The plant cytoskeleton controls regulatory volume increase.
Liu, Qiong; Qiao, Fei; Ismail, Ahmed; Chang, Xiaoli; Nick, Peter
2013-09-01
The ability to adjust cell volume is required for the adaptation to osmotic stress. Plant protoplasts can swell within seconds in response to hypoosmotic shock suggesting that membrane material is released from internal stores. Since the stability of plant membranes depends on submembraneous actin, we asked, whether this regulatory volume control depends on the cytoskeleton. As system we used two cell lines from grapevine which differ in their osmotic tolerance and observed that the cytoskeleton responded differently in these two cell lines. To quantify the ability for regulatory volume control, we used hydraulic conductivity (Lp) as readout and demonstrated a role of the cytoskeleton in protoplast swelling. Chelation of calcium, inhibition of calcium channels, or manipulation of membrane fluidity, did not significantly alter Lp, whereas direct manipulation of the cytoskeleton via specific chemical reagents, or indirectly, through the bacterial elicitor Harpin or activation of phospholipase D, was effective. By optochemical engineering of actin using a caged form of the phytohormone auxin we can break the symmetry of actin organisation resulting in a localised deformation of cell shape indicative of a locally increased Lp. We interpret our findings in terms of a model, where the submembraneous cytoskeleton controls the release of intracellular membrane stores during regulatory volume change. Copyright © 2013 Elsevier B.V. All rights reserved.
Pressurized reactor system and a method of operating the same
Isaksson, J.M.
1996-06-18
A method and apparatus are provided for operating a pressurized reactor system in order to precisely control the temperature within a pressure vessel in order to minimize condensation of corrosive materials from gases on the surfaces of the pressure vessel or contained circulating fluidized bed reactor, and to prevent the temperature of the components from reaching a detrimentally high level, while at the same time allowing quick heating of the pressure vessel interior volume during start-up. Super-atmospheric pressure gas is introduced from the first conduit into the fluidized bed reactor and heat derived reactions such as combustion and gasification are maintained in the reactor. Gas is exhausted from the reactor and pressure vessel through a second conduit. Gas is circulated from one part of the inside volume to another to control the temperature of the inside volume, such as by passing the gas through an exterior conduit which has a heat exchanger, control valve, blower and compressor associated therewith, or by causing natural convection flow of circulating gas within one or more generally vertically extending gas passages entirely within the pressure vessel (and containing heat exchangers, flow rate control valves, or the like therein). Preferably, inert gas is provided as a circulating gas, and the inert gas may also be used in emergency shut-down situations. In emergency shut-down reaction gas being supplied to the reactor is cut off, while inert gas from the interior gas volume of the pressure vessel is introduced into the reactor. 2 figs.
Pressurized reactor system and a method of operating the same
Isaksson, Juhani M.
1996-01-01
A method and apparatus are provided for operating a pressurized reactor system in order to precisely control the temperature within a pressure vessel in order to minimize condensation of corrosive materials from gases on the surfaces of the pressure vessel or contained circulating fluidized bed reactor, and to prevent the temperature of the components from reaching a detrimentally high level, while at the same time allowing quick heating of the pressure vessel interior volume during start-up. Superatmospheric pressure gas is introduced from the first conduit into the fluidized bed reactor and heat derived reactions such as combustion and gassification are maintained in the reactor. Gas is exhausted from the reactor and pressure vessel through a second conduit. Gas is circulated from one part of the inside volume to another to control the temperature of the inside volume, such as by passing the gas through an exterior conduit which has a heat exchanger, control valve, blower and compressor associated therewith, or by causing natural convection flow of circulating gas within one or more generally vertically extending gas passages entirely within the pressure vessel (and containing heat exchangers, flow rate control valves, or the like therein). Preferably, inert gas is provided as a circulating gas, and the inert gas may also be used in emergency shut-down situations. In emergency shut-down reaction gas being supplied to the reactor is cut off, while inert gas from the interior gas volume of the pressure vessel is introduced into the reactor.
Thermal control extravehicular life support system
NASA Technical Reports Server (NTRS)
1975-01-01
The results of a comprehensive study which defined an Extravehicular Life Support System Thermal Control System (TCS) are presented. The design of the prototype hardware and a detail summary of the prototype TCS fabrication and test effort are given. Several heat rejection subsystems, water management subsystems, humidity control subsystems, pressure control schemes and temperature control schemes were evaluated. Alternative integrated TCS systems were studied, and an optimum system was selected based on quantitative weighing of weight, volume, cost, complexity and other factors. The selected subsystem contains a sublimator for heat rejection, bubble expansion tank for water management, a slurper and rotary separator for humidity control, and a pump, a temperature control valve, a gas separator and a vehicle umbilical connector for water transport. The prototype hardware complied with program objectives.
Independent Orbiter Assessment (IOA): Analysis of the reaction control system, volume 3
NASA Technical Reports Server (NTRS)
Burkemper, V. J.; Haufler, W. A.; Odonnell, R. A.; Paul, D. J.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Reaction Control System (RCS). The RCS is situated in three independent modules, one forward in the orbiter nose and one in each OMS/RCS pod. Each RCS module consists of the following subsystems: Helium Pressurization Subsystem; Propellant Storage and Distribution Subsystem; Thruster Subsystem; and Electrical Power Distribution and Control Subsystem. Volume 3 continues the presentation of IOA analysis worksheets and the potential critical items list.
NASA Technical Reports Server (NTRS)
1972-01-01
Laboratory simulations of three concepts, based on maximum use of available off-the-shelf hardware elements, are described. The concepts are a stereo-foveal-peripheral TV system with symmetric steroscopic split-image registration and 90 deg counter rotation; a computer assisted model control system termed the trajectory following control system; and active manipulator damping. It is concluded that the feasibility of these concepts is established.
2017-06-05
DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response...control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) 4. TITLE AND...THIS PAGE 19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 Cost & Performance Report June 2017
Reflective echo tomographic imaging using acoustic beams
Kisner, Roger; Santos-Villalobos, Hector J
2014-11-25
An inspection system includes a plurality of acoustic beamformers, where each of the plurality of acoustic beamformers including a plurality of acoustic transmitter elements. The system also includes at least one controller configured for causing each of the plurality of acoustic beamformers to generate an acoustic beam directed to a point in a volume of interest during a first time. Based on a reflected wave intensity detected at a plurality of acoustic receiver elements, an image of the volume of interest can be generated.
Optimization of the central automatic control of a small Dutch sewer system
NASA Astrophysics Data System (ADS)
Kolechkina, A. G.; Hoes, O. A. C.
2012-04-01
A sewer control system was developed in the context of a subsidized project aiming at improvement of surface water quality by control of sewer systems and surface water systems. The project was coordinated by the local water board, "Waterschap Hollandse Delta". Other participants were Delft University of Technology, Deltares and the municipalities Strijen, Cromstrijen, Westmaas, Oud Beijerland and Piershil. As part of the project there were two pilot implementations where a central automatic controller was coupled to the existing SCADA system. For these two pilots the system is now operational. A Dutch urban area in the western part of the Netherlands is usually part of a polder, which is effectively an artificially drained catchment. The urban area itself is split into small subcatchments that manage runoff in different ways. In all cases a large fraction goes into the natural hydrological cycle, but, depending on the design of the local sewer system, a larger or smaller part finds its way into the sewer system. Proper control of this flow is necessary to control surface water quality and to avoid health risks from flow from the sewer into the streets. At each time step the controller switches pumps to distribute the remaining water in the system at the end of the time step over the different subcatchments. The distribution is created based on expert judgment of the relative vulnerability and subcatchment sewer system water quality. It is implemented in terms curves of total system stored volume versus subcatchment stored volume. We describe the process of the adaptation of a controller to two different sewer systems and the understanding of the artificial part of the catchment we gained during this process. In the process of adaptation the type of sewer system (combined foul water and storm water transport or separate foul water and storm water transport) played a major role.
V/STOL tilt rotor aircraft study. Volume 7: Tilt rotor flight control program feedback studies
NASA Technical Reports Server (NTRS)
Alexander, H. R.; Eason, W.; Gillmore, K.; Morris, J.; Spittle, R.
1973-01-01
An exploratory study has been made of the use of feedback control in tilt rotor aircraft. This has included the use of swashplate cyclic and collective controls and direct lift control. Various sensor and feedback systems are evaluated in relation to blade loads alleviation, improvement in flying qualities, and modal suppression. Recommendations are made regarding additional analytical and wind tunnel investigations and development of feedback systems in the full scale flight vehicle. Estimated costs and schedules are given.
Attitude Control Propulsion Components, Volume 1
NASA Technical Reports Server (NTRS)
1974-01-01
Effort was made to include as much engineering information on each component as possible, consistent with usefulness and catalog size limitations. The contents of this catalog contain components which were qualified for use with spacecraft monopropellant hydrazine and inert gas attitude control systems. Thrust ranges up to 44.5 N (10.0 lbf) for hydrazine and inert gas sytems were considered. Additionally, some components qualified for uses other than spacecraft attitude control are included because they are suitable for use in attitude controls systems.
Electric Drive Study. Volume 1
1987-12-21
CONDITIONER HIGH VOLTAGE DC ICONDITIONER 3 ,300-50 VOLT5), dCONTROL! Figure 5-4. Typical AC Drive System 20 system usable with an induction motor. The...controlling component in an AC drive is the motor power conditioner . This component changes the high voltage DC power to controlled AC power of...selected voltage and frequency which is applied to the drive motors. Since the vehicle gains stored energy as it is accelerated, the motor power conditioner
1981-09-01
centers (OACCs), while units serving oceanic and domestic CTAs are area control centers ( ACCa ). Flight information centers (FICs) provide the non-ATC...Shanwick OACC, and also might be applied by the Santa Maria and Reykjavik ACCa . An alternative procedure permits the inclusion of altitude or time...OACCs), while units serving oceanic and domestic CTAs are area control centers ( ACCa ). Although control centers generally have responsibility for total
Chen, Li; Luo, Tianyou; Lv, Fajin; Shi, Dandan; Qiu, Jiang; Li, Qi; Fang, Weidong; Peng, Juan; Li, Yongmei; Zhang, Zhiwei; Li, Yang
2016-09-01
Clinical studies have shown that thalamus infarction (TI) affects memory function. The thalamic nucleus is directly or indirectly connected to the hippocampal system in animal models. However, this connection has not been investigated using structural magnetic resonance imaging (MRI) in humans. From the pathological perspective, TI patients may serve as valid models for revealing the interaction between the thalamus and hippocampus in memory function. In this study, we aim to assess different hippocampal subfield volumes in TI patients and control subjects using MRI and test their associations with memory function. A total of 37 TI patients (TI group), 38 matched healthy control subjects (HC group), and 22 control patients with other stroke location (SC group) underwent 3.0-T MRI scans and clinical memory examinations. Hippocampal subfield volumes were measured and compared by using FreeSurfer software. We examined the correlation between hippocampal subfield volumes and memory scores. Smaller ipsilesional presubiculum and subiculum volumes were observed, and former was related to graphics recall in both left and right TI patients. The left subiculum volume was correlated with short-delayed recall in left TI patients. The right presubiculum volume was correlated with short- and long-delayed recall in right TI patients. TI was found to result in hippocampal abnormality and memory deficits, and its neural mechanisms might be related with and interaction between the thalamus and hippocampus.
NASA Technical Reports Server (NTRS)
1980-01-01
Helicopter user needs, technology requirements and status, and proposed research and development action are summarized. It is divided into three sections: flight dynamics and control; all weather operations; and human factors.
DOT National Transportation Integrated Search
2017-04-01
Field evaluation of adaptive signal control technologies (ASCT) is very important in understanding the systems contribution to safety : and operational efficiency. Data were collected at six intersections along the Neil Street corridor in Champaig...
Space station systems technology study (add-on task). Volume 3: Technology advancement program plan
NASA Technical Reports Server (NTRS)
1985-01-01
Program plans are given for an integrating controller for space station autonomy as well as for controls and displays. The technical approach, facility requirements and candidate facilities, development schedules, and resource requirements estimates are given.
UMCS feasibility study for Fort George G. Meade. Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-01
Fort George G. Meade selected eighty-three (83) buildings, from the approximately 1,500 buildings on the base to be included in the UMCS Feasibility Study. The purpose of the study is to evaluate the feasibility of replacing the existing analog based Energy Monitoring and Control System (EMCS) with a new distributed process Monitoring and Control System (UMCS).
UMCS feasibility study for Fort George G. Meade volume 1. Feasibility study
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-01
Fort George G. Meade selected 83 buildings, from the approximately 1,500 buildings on the base to be included in the UMCS Feasibility Study. The purpose of the study is to evaluate the feasibility of replacing the existing analog based Energy Monitoring and Control System (EMCS) with a new distributed process Monitoring and Control System (UMCS).
NASA Technical Reports Server (NTRS)
1979-01-01
The functional, performance, design, and test requirements for the Orbiter power extension package and its associated ground support equipment are defined. Both government and nongovernment standards and specifications are cited for the following subsystems: electrical power, structural/mechanical, avionics, and thermal control. Quality control assurance provisions and preparation for delivery are also discussed.
1976-03-01
DB DC DCT DDB DET DF DFS DML DMS DMSP DOD DS DSARC DT EDB EDS EG ESSA ETAC EWO Control and Reporting Post Cathode Ray Tube...National and Aviation Meteorological Facsimile Network NC - Network Control NCA - National Command Authority NCAR - National Center for Atmospheric
Inductive Interference in Rapid Transit Signaling Systems. Volume 1. Theory and Background.
DOT National Transportation Integrated Search
1986-05-01
This report describes the mechanism of inductive interference to audio frequency (AF) signaling systems used in rail transit operations, caused by rail transit vehicles with chopper propulsion control. Choppers are switching circuits composed of high...
Analysis of Hydraulic Servo Equations for WRDRF Prototype Control System : Volume I
DOT National Transportation Integrated Search
1971-10-01
A set of dynamic performance equations derived by Wylie Labs., Huntsville, Alabama, were independently rederived and checked. These equations describe the perfromance of the prototype electro hydraulic servo actuator system selected by Wylie as repre...
NASA Technical Reports Server (NTRS)
1982-01-01
The active control technology (ACT) control/guidance system task of the integrated application of active controls (IAAC) technology project within the NASA energy efficient transport program was documented. The air traffic environment of navigation and air traffic control systems and procedures were extrapolated. An approach to listing flight functions which will be performed by systems and crew of an ACT configured airplane of the 1990s, and a determination of function criticalities to safety of flight, are the basis of candidate integrated ACT/Control/Guidance System architecture. The system mechanizes five active control functions: pitch augmented stability, angle of attack limiting, lateral/directional augmented stability, gust load alleviation, and maneuver load control. The scope and requirements of a program for simulating the integrated ACT avionics and flight deck system, with pilot in the loop, are defined, system and crew interface elements are simulated, and mechanization is recommended. Relationships between system design and crew roles and procedures are evaluated.
Quantitative evaluation of the voice range profile in patients with voice disorder.
Ikeda, Y; Masuda, T; Manako, H; Yamashita, H; Yamamoto, T; Komiyama, S
1999-01-01
In 1953, Calvet first displayed the fundamental frequency (pitch) and sound pressure level (intensity) of a voice on a two-dimensional plane and created a voice range profile. This profile has been used to evaluate clinically various vocal disorders, although such evaluations to date have been subjective without quantitative assessment. In the present study, a quantitative system was developed to evaluate the voice range profile utilizing a personal computer. The area of the voice range profile was defined as the voice volume. This volume was analyzed in 137 males and 175 females who were treated for various dysphonias at Kyushu University between 1984 and 1990. Ten normal subjects served as controls. The voice volume in cases with voice disorders significantly decreased irrespective of the disease and sex. Furthermore, cases having better improvement after treatment showed a tendency for the voice volume to increase. These findings illustrated the voice volume as a useful clinical test for evaluating voice control in cases with vocal disorders.
DOT National Transportation Integrated Search
1976-03-01
The spectral characteristics of the urban center -- at the level of the family, the functional organized units of society, and the essential compartment balances of the urban center -- are spelled out in greater detail. These compartments are food, m...
Hippocampus shape analysis and late-life depression.
Zhao, Zheen; Taylor, Warren D; Styner, Martin; Steffens, David C; Krishnan, K Ranga R; MacFall, James R
2008-03-19
Major depression in the elderly is associated with brain structural changes and vascular lesions. Changes in the subcortical regions of the limbic system have also been noted. Studies examining hippocampus volumetric differences in depression have shown variable results, possibly due to any volume differences being secondary to local shape changes rather than differences in the overall volume. Shape analysis offers the potential to detect such changes. The present study applied spherical harmonic (SPHARM) shape analysis to the left and right hippocampi of 61 elderly subjects with major depression and 43 non-depressed elderly subjects. Statistical models controlling for age, sex, and total cerebral volume showed a significant reduction in depressed compared with control subjects in the left hippocampus (F(1,103) = 5.26; p = 0.0240) but not right hippocampus volume (F(1,103) = 0.41; p = 0.5213). Shape analysis showed significant differences in the mid-body of the left (but not the right) hippocampus between depressed and controls. When the depressed group was dichotomized into those whose depression was remitted at time of imaging and those who were unremitted, the shape comparison showed remitted subjects to be indistinguishable from controls (both sides) while the unremitted subjects differed in the midbody and the lateral side near the head. Hippocampal volume showed no difference between controls and remitted subjects but nonremitted subjects had significantly smaller left hippocampal volumes with no significant group differences in the right hippocampus. These findings may provide support to other reports of neurogenic effects of antidepressants and their relation to successful treatment for depressive symptoms.
Sample preparation system for microfluidic applications
Mosier, Bruce P [San Francisco, CA; Crocker, Robert W [Fremont, CA; Patel, Kamlesh D [Dublin, CA; Harnett, Cindy K [Livermore, CA
2007-05-08
An apparatus that couples automated injection with flow feedback to provide nanoliter accuracy in controlling microliter volumes. The apparatus comprises generally a source of hydraulic fluid pressure, a fluid isolator joined to the outlet of the hydraulic pressure source and a flow sensor to provide pressure-driven analyte metering. For operation generally and particularly in microfluidic systems the hydraulic pressure source is typically an electrokinetic (EK) pump that incorporates gasless electrodes. The apparatus is capable of metering sub-microliter volumes at flowrates of 1 100 .mu.L/min into microsystem load pressures of up to 1000 50 psi, respectively. Flowrates can be specified within 0.5 .mu.L/min and volumes as small as 80 nL can be metered.
Active Control of pH in the Bioculture System Through Carbon Dioxide Control
NASA Technical Reports Server (NTRS)
Monhollon, Luke; Pletcher, David; Hauss, Jessica
2016-01-01
For successful cell research, the growth culture environment must be tightly controlled. Deviance from the optimal conditions will mask the desired variable being analyzed or lead to inconstancies in the results. In standard laboratories, technology and procedures are readily available for the reliable control of variables such as temperature, pH, nutrient loading, and dissolved gases. Due to the nature of spaceflight, and the inherent constraints to engineering designs, these same elements become a challenge to maintain at stable values by both automated and manual approaches. Launch mass, volume, and power usage create significant constraints to cell culture systems; nonetheless, innovative solutions for active environmental controls are available. The acidity of the growth media cannot be measured through standard probes due to the degradation of electrodes and reliance on indicators for chromatography. Alternatively, carbon dioxide sensors are capable of monitoring the pH by leveraging the relationship between the partial pressure of carbon dioxide and carbonic acid in solution across a membrane. In microgravity cell growth systems, the gas delivery system can be used to actively maintain the media at the proper acidity by maintaining a suitable gas mixture around permeable tubing. Through this method, launch mass and volume are significantly reduced through the efficient use of the limited gas supply in orbit.
A novel pressure-driven piezodispenser for nanoliter volumes.
McGuire, Shawn; Fisher, Charles; Holl, Mark; Meldrum, Deirdre
2008-08-01
A successful dispensing device has been built for use in biotechnology applications requiring nanoliter volume liquid transfer. Air pressure is used as the primary driving force and is controlled via a high speed miniature solenoid valve as opposed to many existing systems that use a valve in line with constantly pressurized fluid to start and stop the dispensing action. This automated pressure-driven system is used to improve a typical piezodriven microdispenser. The resulting system is much less prone to failures resulting from air entrainment and can dispense much higher viscosity fluids than the microdispenser alone.
Small Aircraft Transportation System Higher Volume Operations Concept
NASA Technical Reports Server (NTRS)
Abbott, Terence S.; Consiglio, Maria C.; Baxley, Brian T.; Williams, Daniel M.; Jones, Kenneth M.; Adams, Catherine A.
2006-01-01
This document defines the Small Aircraft Transportation System (SATS) Higher Volume Operations concept. The general philosophy underlying this concept is the establishment of a newly defined area of flight operations called a Self-Controlled Area (SCA). Within the SCA, pilots would take responsibility for separation assurance between their aircraft and other similarly equipped aircraft. This document also provides details for a number of off-nominal and emergency procedures which address situations that could be expected to occur in a future SCA. The details for this operational concept along with a description of candidate aircraft systems to support this concept are provided.
High call volume at poison control centers: identification and implications for communication
CARAVATI, E. M.; LATIMER, S.; REBLIN, M.; BENNETT, H. K. W.; CUMMINS, M. R.; CROUCH, B. I.; ELLINGTON, L.
2016-01-01
Context High volume surges in health care are uncommon and unpredictable events. Their impact on health system performance and capacity is difficult to study. Objectives To identify time periods that exhibited very busy conditions at a poison control center and to determine whether cases and communication during high volume call periods are different from cases during low volume periods. Methods Call data from a US poison control center over twelve consecutive months was collected via a call logger and an electronic case database (Toxicall®). Variables evaluated for high call volume conditions were: (1) call duration; (2) number of cases; and (3) number of calls per staff member per 30 minute period. Statistical analyses identified peak periods as busier than 99% of all other 30 minute time periods and low volume periods as slower than 70% of all other 30 minute periods. Case and communication characteristics of high volume and low volume calls were compared using logistic regression. Results A total of 65,364 incoming calls occurred over 12 months. One hundred high call volume and 4885 low call volume 30 minute periods were identified. High volume periods were more common between 1500 and 2300 hours and during the winter months. Coded verbal communication data were evaluated for 42 high volume and 296 low volume calls. The mean (standard deviation) call length of these calls during high volume and low volume periods was 3 minutes 27 seconds (1 minute 46 seconds) and 3 minutes 57 seconds (2 minutes 11 seconds), respectively. Regression analyses revealed a trend for fewer overall verbal statements and fewer staff questions during peak periods, but no other significant differences for staff-caller communication behaviors were found. Conclusion Peak activity for poison center call volume can be identified by statistical modeling. Calls during high volume periods were similar to low volume calls. Communication was more concise yet staff was able to maintain a good rapport with callers during busy call periods. This approach allows evaluation of poison exposure call characteristics and communication during high volume periods. PMID:22889059
High call volume at poison control centers: identification and implications for communication.
Caravati, E M; Latimer, S; Reblin, M; Bennett, H K W; Cummins, M R; Crouch, B I; Ellington, L
2012-09-01
High volume surges in health care are uncommon and unpredictable events. Their impact on health system performance and capacity is difficult to study. To identify time periods that exhibited very busy conditions at a poison control center and to determine whether cases and communication during high volume call periods are different from cases during low volume periods. Call data from a US poison control center over twelve consecutive months was collected via a call logger and an electronic case database (Toxicall®).Variables evaluated for high call volume conditions were: (1) call duration; (2) number of cases; and (3) number of calls per staff member per 30 minute period. Statistical analyses identified peak periods as busier than 99% of all other 30 minute time periods and low volume periods as slower than 70% of all other 30 minute periods. Case and communication characteristics of high volume and low volume calls were compared using logistic regression. A total of 65,364 incoming calls occurred over 12 months. One hundred high call volume and 4885 low call volume 30 minute periods were identified. High volume periods were more common between 1500 and 2300 hours and during the winter months. Coded verbal communication data were evaluated for 42 high volume and 296 low volume calls. The mean (standard deviation) call length of these calls during high volume and low volume periods was 3 minutes 27 seconds (1 minute 46 seconds) and 3 minutes 57 seconds (2 minutes 11 seconds), respectively. Regression analyses revealed a trend for fewer overall verbal statements and fewer staff questions during peak periods, but no other significant differences for staff-caller communication behaviors were found. Peak activity for poison center call volume can be identified by statistical modeling. Calls during high volume periods were similar to low volume calls. Communication was more concise yet staff was able to maintain a good rapport with callers during busy call periods. This approach allows evaluation of poison exposure call characteristics and communication during high volume periods.
Space Station Systems Analysis Study. Volume 2: Program review report
NASA Technical Reports Server (NTRS)
1977-01-01
Major growth options for tended and manned space stations in LEO and GEO are examined including increased orbiter augmentation and habitation requirements. Approaches for providing power supplies, construction aids needed to assemble support platforms, transportation system constraints, and the hardware required for various missions categories are defined. Subsystem requirements are analyzed for structure; flight control; power generation and storage; avionic; life support systems; personnel provisions; and environmental control. Tradeoffs are considered.
Development of a miniaturized deformable mirror controller
NASA Astrophysics Data System (ADS)
Bendek, Eduardo; Lynch, Dana; Pluzhnik, Eugene; Belikov, Ruslan; Klamm, Benjamin; Hyde, Elizabeth; Mumm, Katherine
2016-07-01
High-Performance Adaptive Optics systems are rapidly spreading as useful applications in the fields of astronomy, ophthalmology, and telecommunications. This technology is critical to enable coronagraphic direct imaging of exoplanets utilized in ground-based telescopes and future space missions such as WFIRST, EXO-C, HabEx, and LUVOIR. We have developed a miniaturized Deformable Mirror controller to enable active optics on small space imaging mission. The system is based on the Boston Micromachines Corporation Kilo-DM, which is one of the most widespread DMs on the market. The system has three main components: The Deformable Mirror, the Driving Electronics, and the Mechanical and Heat management. The system is designed to be extremely compact and have lowpower consumption to enable its use not only on exoplanet missions, but also in a wide-range of applications that require precision optical systems, such as direct line-of-sight laser communications, and guidance systems. The controller is capable of handling 1,024 actuators with 220V maximum dynamic range, 16bit resolution, and 14bit accuracy, and operating at up to 1kHz frequency. The system fits in a 10x10x5cm volume, weighs less than 0.5kg, and consumes less than 8W. We have developed a turnkey solution reducing the risk for currently planned as well as future missions, lowering their cost by significantly reducing volume, weight and power consumption of the wavefront control hardware.
Epstein, R H; Dexter, F
2000-08-01
Operating room (OR) scheduling information systems can decrease perioperative labor costs. Material management information systems can decrease perioperative inventory costs. We used computer simulation to investigate whether using the OR schedule to trigger purchasing of perioperative supplies is likely to further decrease perioperative inventory costs, as compared with using sophisticated, stand-alone material management inventory control. Although we designed the simulations to favor financially linking the information systems, we found that this strategy would be expected to decrease inventory costs substantively only for items of high price ($1000 each) and volume (>1000 used each year). Because expensive items typically have different models and sizes, each of which is used by a hospital less often than this, for almost all items there will be no benefit to making daily adjustments to the order volume based on booked cases. We conclude that, in a hospital with a sophisticated material management information system, OR managers will probably achieve greater cost reductions from focusing on negotiating less expensive purchase prices for items than on trying to link the OR information system with the hospital's material management information system to achieve just-in-time inventory control. In a hospital with a sophisticated material management information system, operating room managers will probably achieve greater cost reductions from focusing on negotiating less expensive purchase prices for items than on trying to link the operating room information system with the hospital's material management information system to achieve just-in-time inventory control.
Fölsch, Christian; Goost, Hans; Figiel, Jens; Paletta, Jürgen R J; Schultz, Wolfgang; Lakemeier, Stefan
2012-12-01
Cement augmentation of pedicle screws increases fixation strength in an osteoporotic spine. This study was designed to determine the cement distribution and the correlation between the pull-out strength of the augmented screw and the cement volume within polyurethane (PU) foam. Twenty-eight cannulated pedicle screws (6×45 mm) (Peter Brehm, Erlangen, Germany) with four holes at the distal end of the screw were augmented with the acrylic Stabilit ER Bone Cement Vertebral Augmentation System (DFine Inc., San Jose, CA, USA) and implanted into open-cell rigid PU foam (Pacific Research Laboratories, Vashon Island, WA, USA) with a density of 0.12 g/cm3, resembling severe osteoporosis. Volumetric measurement of the cement with consideration of the distribution around the screws was done with multislice computed tomography scan (Somatom Definition, Siemens, Erlangen, Germany). Pull-out strength was tested with a servohydraulic system (MTS System Corporation, Eden Prairie, MN, USA), and nonaugmented screws served as control. Pearson's correlation coefficient with significance level α=0.05 and one-way analysis of variance test were used. We found a high (r=0.88) and significant (p<0.01) correlation between the cement volume and the pull-out strength, which increased by more than 5-fold with a volume of 3 ml. The correlation appeared linear at least up to 4 ml cement volume and failure always occurred at the cement-bone interface. The cement distribution was symmetric and circular around the most proximal hole, with a distance of 14 mm from the tip, and nearly 90% of the cement was found 6 mm distal and cranial to it. The 95% confidence interval for the relative amount of cement was 37%-41% within 2 mm of the most proximal hole. Compared with the control, a cement volume between 2.0 and 3.0 ml increased the pull-out strength significantly and is relevant for clinical purposes, whereas a volume of 0.5 ml did not. A cement volume beyond 3.0 ml should further increase the pull-out strength because the correlation was linear at least up to 4.0 ml, but the possibility of in vivo cement leakage with increasing volume has to be considered. Pressure-controlled cement application might be a tool to avoid this complication. The cement almost completely penetrated the most proximal perforation.
A low power, microvalve regulated architecture for drug delivery systems.
Evans, Allan Thomas; Park, Jong M; Chiravuri, Srinivas; Gianchandani, Yogesh B
2010-02-01
This paper describes an actively-controlled architecture for drug delivery systems that offers high performance and volume efficiency through the use of micromachined components. The system uses a controlled valve to regulate dosing by throttling flow from a mechanically pressurized reservoir, thereby eliminating the need for a pump. To this end, the valve is fabricated from a glass wafer and silicon-on-insulator wafer for sensor integration. The valve draws a maximum power of 1.68 μW| (averaged over time); with the existing packaging scheme, it has a volume of 2.475 cm3. The reservoirs are assembled by compressing polyethylene terephthalate polymer balloons with metal springs. The metal springs are fabricated from Elgiloy® using photochemical etching. The springs pressurize the contents of 37 mLchambers up to 15 kPa. The system is integrated with batteries and a control circuit board within a 113 cm3 metal casing. This system has been evaluated in different control modes to mimic clinical applications. Bolus deliveries of1.5 mL have been regulated as well as continuous flows of 0.15 mL/day with accuracies of 3.22%. The results suggest that this device can be used in an implant to regulate intrathecal drug delivery
In-space propellant systems safety. Volume 3: System safety analysis
NASA Technical Reports Server (NTRS)
1972-01-01
The primary objective was to examine from a system safety viewpoint in-space propellant logistic elements and operations to define the potential hazards and to recommend means to reduce, eliminate or control them. A secondary objective was to conduct trade studies of specific systems or operations to determine the safest of alternate approaches.
NASA Technical Reports Server (NTRS)
1983-01-01
Various parameters of the orbital space station are discussed. The space station environment, data management system, communication and tracking, environmental control, and life support system are considered. Specific topics reviewed include crew work stations, restraint systems, stowage, computer hardware, and expert systems.
Niimi, Yoshinari; Murata, Seiichiro; Mitou, Yumi; Ohno, Yusuke
2018-03-01
We developed a novel open cardiopulmonary bypass (CPB) system, a drainage flow servo-controlled CPB system (DS-CPB), in which rotational speed of the main roller pump is servo-controlled to generate the same amount of flow as the systemic venous drainage. It was designed to safely decrease the priming volume while maintaining a constant reservoir level, even during fluctuations of the drainage flow. We report a successful use of a novel DS-CPB system in an elderly Jehovah's Witness patient with dehydration who underwent mitral valve replacement.
1983-08-01
for the level of manage- 5AR ment reviewing it ., (40) The Cost Schedule Control Systems PROD R&D Criteria are not a...evolution and development of the Cost/Schedule Control Vice President, Contracts and Pricing Systems Criteria (C/SCSC), then analyze its cost impact...don’t come and ask for what we are going to war with-not He is taking the tough position to en- funding to cover it -find out what the new system
NASA Technical Reports Server (NTRS)
1973-01-01
An analysis of cryogenic fluid cooling in the environmental control system of the space shuttle was conducted. The technique for treating the cryogenic fluid storage and supply tanks and subsystems as integrated systems was developed. It was concluded that a basic incompatibility exists between the heat generated and the cryogen usage rate and cryogens cannot be used to absorb the generated heat. The use of radiators and accumulators to provide additional cooling capability is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, E.R.
1983-09-01
The appendixes for the Saguaro Power Plant includes the following: receiver configuration selection report; cooperating modes and transitions; failure modes analysis; control system analysis; computer codes and simulation models; procurement package scope descriptions; responsibility matrix; solar system flow diagram component purpose list; thermal storage component and system test plans; solar steam generator tube-to-tubesheet weld analysis; pipeline listing; management control schedule; and system list and definitions.
Experimental teaching and training system based on volume holographic storage
NASA Astrophysics Data System (ADS)
Jiang, Zhuqing; Wang, Zhe; Sun, Chan; Cui, Yutong; Wan, Yuhong; Zou, Rufei
2017-08-01
The experiment of volume holographic storage for teaching and training the practical ability of senior students in Applied Physics is introduced. The students can learn to use advanced optoelectronic devices and the automatic control means via this experiment, and further understand the theoretical knowledge of optical information processing and photonics disciplines that have been studied in some courses. In the experiment, multiplexing holographic recording and readout is based on Bragg selectivity of volume holographic grating, in which Bragg diffraction angle is dependent on grating-recording angel. By using different interference angle between reference and object beams, the holograms can be recorded into photorefractive crystal, and then the object images can be read out from these holograms via angular addressing by using the original reference beam. In this system, the experimental data acquisition and the control of the optoelectronic devices, such as the shutter on-off, image loaded in SLM and image acquisition of a CCD sensor, are automatically realized by using LabVIEW programming.
Reliability of Vibrating Mesh Technology.
Gowda, Ashwin A; Cuccia, Ann D; Smaldone, Gerald C
2017-01-01
For delivery of inhaled aerosols, vibrating mesh systems are more efficient than jet nebulizers are and do not require added gas flow. We assessed the reliability of a vibrating mesh nebulizer (Aerogen Solo, Aerogen Ltd, Galway Ireland) suitable for use in mechanical ventilation. An initial observational study was performed with 6 nebulizers to determine run time and efficiency using normal saline and distilled water. Nebulizers were run until cessation of aerosol production was noted, with residual volume and run time recorded. Three controllers were used to assess the impact of the controller on nebulizer function. Following the observational study, a more detailed experimental protocol was performed using 20 nebulizers. For this analysis, 2 controllers were used, and time to cessation of aerosol production was noted. Gravimetric techniques were used to measure residual volume. Total nebulization time and residual volume were recorded. Failure was defined as premature cessation of aerosol production represented by residual volume of > 10% of the nebulizer charge. In the initial observational protocol, an unexpected sporadic failure rate was noted of 25% in 55 experimental runs. In the experimental protocol, a failure rate was noted of 30% in 40 experimental runs. Failed runs in the experimental protocol exhibited a wide range of retained volume averaging ± SD 36 ± 21.3% compared with 3.2 ± 1.5% (P = .001) in successful runs. Small but significant differences existed in nebulization time between controllers. Aerogen Solo nebulization was often randomly interrupted with a wide range of retained volumes. Copyright © 2017 by Daedalus Enterprises.
NASA Technical Reports Server (NTRS)
Larson, V. R.; Gunn, S. V.; Lee, J. C.
1975-01-01
The paper describes a helium heater to be used to conduct non-nuclear demonstration tests of the complete power conversion loop for a direct-cycle gas-cooled nuclear reactor power plant. Requirements for the heater include: heating the helium to a 1500 F temperature, operating at a 1000 psia helium pressure, providing a thermal response capability and helium volume similar to that of the nuclear reactor, and a total heater system helium pressure drop of not more than 15 psi. The unique compact heater system design proposed consists of 18 heater modules; air preheaters, compressors, and compressor drive systems; an integral control system; piping; and auxiliary equipment. The heater modules incorporate the dual-concentric-tube 'Variflux' heat exchanger design which provides a controlled heat flux along the entire length of the tube element. The heater design as proposed will meet all system requirements. The heater uses pressurized combustion (50 psia) to provide intensive heat transfer, and to minimize furnace volume and heat storage mass.
Focus control system for stretched-membrane mirror module
Butler, B.L.; Beninga, K.J.
1991-05-21
A focus control system dynamically sets and controls the focal length of a reflective membrane supported between a perimeter frame. A rear membrane is also supported between the perimeter frame rearward and spaced apart from a back side of the reflective membrane. The space between the membranes defines a plenum space into which a mass of gas at a first pressure is inserted. The pressure differential between the first pressure and an external pressure, such as the atmospheric pressure, causes the reflective membrane to assume a first curvature relative to a reference plane associated with the perimeter frame. This curvature defines the focal length of the reflective membrane. The focal length is dynamically controlled by changing the volume of the plenum space, thereby changing the first pressure. The system can be used to change or maintain the pressure differential and hence the front membrane curvature. The plenum volume is changed by pushing or pulling on a central section of the rear membrane using a suitable actuator. Sensing means continuously sense the location of the reflective membrane relative to the reference plane. This sensed position is compared to a reference position, and a resulting error signal, comprising the difference between the sensed position and reference position, drives the actuator in a direction to minimize the difference. A vent value compensates for temperature changes or leaks in the closed volume by allowing the pressure differential to be adjusted as required to center the working range of the actuator about the desired focal length. 13 figures.
Focus control system for stretched-membrane mirror module
Butler, Barry L.; Beninga, Kelly J.
1991-01-01
A focus control system dynamically sets and controls the focal length of a reflective membrane supported between a perimeter frame. A rear membrane is also supported between the perimeter frame rearward and spaced apart from a back side of the reflective membrane. The space between the membranes defines a plenum space into which a mass of gas at a first pressure is inserted. The pressure differential between the first pressure and an external pressure, such as the atmospheric pressure, causes the reflective membrane to assume a first curvature relative to a reference plane associated with the perimeter frame. This curvature defines the focal length of the reflective membrane. The focal length is dynamically controlled by changing the volume of the plenum space, thereby changing the first pressure. The system can be used to change or maintain the pressure differential and hence the front membrane curvature. The plenum volume is changed by pushing or pulling on a central section of the rear membrane using a suitable actuator. Sensing means continuously sense the location of the reflective membrane relative to the reference plane. This sensed position is compared to a reference position, and a resulting error signal, comprising the difference between the sensed position and reference position, drives the actuator in a direction to minimize the difference. A vent value compensates for temperature changes or leaks in the closed volume by allowing the pressure differential to be adjusted as required to center the working range of the actuator about the desired focal length.
Korucu, M Kemal; Gedik, Kadir; Weber, Roland; Karademir, Aykan; Kurt-Karakus, Perihan Binnur
2015-10-01
Perfluorooctane sulfonic acid (PFOS) and related substances have been listed as persistent organic pollutants (POPs) in the Stockholm Convention. Countries which have ratified the Convention need to take appropriate actions to control PFOS use and release. This study compiles and enhances the findings of the first inventory of PFOS and related substances use in Turkey conducted within the frame of the Stockholm Convention National Implementation Plan (NIP) update. The specific Harmonized Commodity Description and Coding System (Harmonized System (HS)) codes of imported and exported goods that possibly contain PFOS and 165 of Chemical Abstracts Service (CAS) numbers of PFOS-related substances were assessed for acquiring information from customs and other authorities. However, with the current approaches available, no useful information could be compiled since HS codes are not specific enough and CAS numbers are not used by customs. Furthermore, the cut-off volume in chemical databases in Turkey and the reporting limit in the HS system (0.1 %) are too high for controlling PFOS. The attempt of modeling imported volumes by a Monte Carlo simulation did not also result in a satisfactory estimate, giving an upper-bound estimate above the global production volumes. The replies to questionnaires were not satisfactory, highlighting that an elaborated approach is needed in the communication with potentially PFOS-using stakeholders. The experience of the challenges of gathering information on PFOS in articles and products revealed the gaps of controlling highly hazardous substances in products and articles and the need of improvements.
Solar power satellite system definition study, phase 2. Volume 2: Reference system description
NASA Technical Reports Server (NTRS)
1979-01-01
System descriptions and cost estimates for the reference system of the solar power satellite program are presented. The reference system is divided into five principal elements: the solar power satellites; space construction and support; space and ground transportation; ground receiving stations; and operations control. The program scenario and non-recurring costs are briefly described.
Using Agent-Based Modeling to Enhance System-Level Real-time Control of Urban Stormwater Systems
NASA Astrophysics Data System (ADS)
Rimer, S.; Mullapudi, A. M.; Kerkez, B.
2017-12-01
The ability to reduce combined-sewer overflow (CSO) events is an issue that challenges over 800 U.S. municipalities. When the volume of a combined sewer system or wastewater treatment plant is exceeded, untreated wastewater then overflows (a CSO event) into nearby streams, rivers, or other water bodies causing localized urban flooding and pollution. The likelihood and impact of CSO events has only exacerbated due to urbanization, population growth, climate change, aging infrastructure, and system complexity. Thus, there is an urgent need for urban areas to manage CSO events. Traditionally, mitigating CSO events has been carried out via time-intensive and expensive structural interventions such as retention basins or sewer separation, which are able to reduce CSO events, but are costly, arduous, and only provide a fixed solution to a dynamic problem. Real-time control (RTC) of urban drainage systems using sensor and actuator networks has served as an inexpensive and versatile alternative to traditional CSO intervention. In particular, retrofitting individual stormwater elements for sensing and automated active distributed control has been shown to significantly reduce the volume of discharge during CSO events, with some RTC models demonstrating a reduction upwards of 90% when compared to traditional passive systems. As more stormwater elements become retrofitted for RTC, system-level RTC across complete watersheds is an attainable possibility. However, when considering the diverse set of control needs of each of these individual stormwater elements, such system-level RTC becomes a far more complex problem. To address such diverse control needs, agent-based modeling is employed such that each individual stormwater element is treated as an autonomous agent with a diverse decision making capabilities. We present preliminary results and limitations of utilizing the agent-based modeling computational framework for the system-level control of diverse, interacting stormwater elements.
Funakoshi, Kouta; Hosokawa, Kazuya; Kishi, Takuya; Ide, Tomomi; Sunagawa, Kenji
2014-01-01
Patients with heart failure and preserved ejection fraction (HFpEF) are supersensitive to volume overload, and a striking increase in left atrial pressure (LAP) often occurs transiently and is rapidly resolved by intravascular volume reduction. The arterial baroreflex is a powerful regulator of intravascular stressed blood volume. We examined whether arterial baroreflex failure (FAIL) mimicked by constant carotid sinus pressure (CSP) causes a striking increase in LAP and systemic arterial pressure (AP) by volume loading in rats with normal left ventricular (LV) function. In anesthetized Sprague-Dawley rats, we isolated bilateral carotid sinuses and controlled CSP by a servo-controlled piston pump. We mimicked the normal arterial baroreflex by matching CSP to instantaneous AP and FAIL by maintaining CSP at a constant value regardless of AP. We infused dextran stepwise (infused volume [Vi]) until LAP reached 15 mm Hg and obtained the LAP-Vi relationship. We estimated the critical Vi as the Vi at which LAP reached 20 mm Hg. In FAIL, critical Vi decreased markedly from 19.4 ± 1.6 mL/kg to 15.6 ± 1.6 mL/kg (P < .01), whereas AP at the critical Vi increased (194 ± 6 mm Hg vs 163 ± 6 mm Hg; P < .01). We demonstrated that an artificial arterial baroreflex system we recently developed could fully restore the physiologic volume intolerance in the absence of native arterial baroreflex. Arterial baroreflex failure induces striking volume intolerance in the absence of LV dysfunction and may play an important role in the pathogenesis of acute heart failure, especially in states of HFpEF. Copyright © 2014 Elsevier Inc. All rights reserved.
Combined Global Navigation Satellite Systems in the Space Service Volume
NASA Technical Reports Server (NTRS)
Force, Dale A.; Miller, James J.
2015-01-01
Besides providing position, navigation, and timing (PNT) services to traditional terrestrial and airborne users, GPS is also being increasingly used as a tool to enable precision orbit determination, precise time synchronization, real-time spacecraft navigation, and three-axis attitude control of Earth orbiting satellites. With additional Global Navigation Satellite System (GNSS) constellations being replenished and coming into service (GLONASS, Beidou, and Galileo), it will become possible to benefit from greater signal availability and robustness by using evolving multi-constellation receivers. The paper, "GPS in the Space Service Volume," presented at the ION GNSS 19th International Technical Meeting in 2006 (Ref. 1), defined the Space Service Volume, and analyzed the performance of GPS out to seventy thousand kilometers. This paper will report a similar analysis of the signal coverage of GPS in the space domain; however, the analyses will also consider signal coverage from each of the additional GNSS constellations noted earlier to specifically demonstrate the expected benefits to be derived from using GPS in conjunction with other foreign systems. The Space Service Volume is formally defined as the volume of space between three thousand kilometers altitude and geosynchronous altitude circa 36,000 km, as compared with the Terrestrial Service Volume between 3,000 km and the surface of the Earth. In the Terrestrial Service Volume, GNSS performance is the same as on or near the Earth's surface due to satellite vehicle availability and geometry similarities. The core GPS system has thereby established signal requirements for the Space Service Volume as part of technical Capability Development Documentation (CDD) that specifies system performance. Besides the technical discussion, we also present diplomatic efforts to extend the GPS Space Service Volume concept to other PNT service providers in an effort to assure that all space users will benefit from the enhanced interoperability of GNSS services in the space domain. A separate paper presented at the conference covers the individual GNSS performance parameters for respective Space Service Volumes.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... Classification System. \\2\\ Maximum Achievable Control Technology. Table 2 is not intended to be exhaustive, but..., methods, systems, or techniques that reduce the volume of or eliminate HAP emissions through process changes, substitution of materials, or other modifications; enclose systems or processes to eliminate...
DOT National Transportation Integrated Search
1990-01-01
The validation and evaluation of an expert system for traffic control in highway work zones (TRANZ) is described. The stages in the evaluation process consisted of the following: revisit the experts, selectively distribute copies of TRANZ with docume...
DOT National Transportation Integrated Search
1975-10-01
This report details the result of an experiment performed by the Transportation Systems Center of the Department of Transportation to evaluate candidate voice and data modulation systems for use in an L-Band Air Traffic Control System. The experiment...
NASA Technical Reports Server (NTRS)
Anderson, W. F.; Conway, J. R.; Keller, L. C.
1972-01-01
The characteristics of the application program were developed to verify and demonstrate the SEL 840MP Multi-Processing Control System - Version I (MPCS/1). The application program emphasizes the display support and task control capabilities. The application program is further intended to be used as an aid to familization with MPCS/1. It complements the information provided in the MPCS/1 Users Guide, Volume I and II.
Brisch, Ralf; Bernstein, Hans-Gert; Dobrowolny, Henrik; Krzyżanowska, Marta; Jankowski, Zbigniew; Bogerts, Bernhard; Gos, Tomasz
2016-05-01
The human diagonal band of Broca is connected to other parts of the limbic system, such as the hippocampus, that are involved in the pathology of schizophrenia. This study aimed to characterize the volume and anterior-to-posterior distance of the human diagonal band of Broca (vertical limb) from post-mortem brains obtained from three groups: healthy control subjects (N = 17), patients with schizophrenia (N = 26), and patients with affective disorders (N = 12). There were no significant differences in the volume or anterior-to-posterior distance in the patients with schizophrenia or affective disorders compared with the healthy control subjects. To date, this is the first post-mortem investigation measuring the volume and the anterior-to-posterior distance of the diagonal band of Broca (vertical limb) in patients with schizophrenia or affective disorders compared with healthy control subjects. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
1974-01-01
The functional, performance, and design requirements for the Operations Control Center (OCC) of the Earth Observatory Satellite (EOS) system are presented. The OCC controls the operations of the EOS satellite to acquire mission data consisting of: (1) thematic mapper data, (2) multispectral scanner data on EOS-A, or High Resolution Pointable Imager data on EOS-B, and (3) data collection system (DCS) data. The various inputs to the OCC are identified. The functional requirements of the OCC are defined. The specific systems and subsystems of the OCC are described and block diagrams are provided.
NASA Technical Reports Server (NTRS)
1973-01-01
The evaluation of candidate cryogenic fuel systems for space shuttle vehicles is discussed. A set of guidelines was used to establish a matrix of possible combinations for the integration of potential cryogenic systems. The various concepts and combinations which resulted from the integration efforts are described. The parameters which were considered in developing the matrix are: (1) storage of cryogenic materials, (2) fuel lines, (3) tank pressure control, (4) thermal control, (5) fluid control, and (6) fluid conditioning. Block diagrams and drawings of the candidate systems are provided. Performance predictions for the systems are outlined in tables of data.
Neural Control of the Cardiovascular System in Space
NASA Technical Reports Server (NTRS)
Levine, Benjamin D.; Pawelczyk, James A.; Zuckerman, Julie; Zhang, Rong; Fu, Qi; Iwasaki, Kenichi; Ray, Chet; Blomqvist, C. Gunnar; Lane, Lynda D.; Giller, Cole A.
2003-01-01
During the acute transition from lying supine to standing upright, a large volume of blood suddenly moves from the chest into the legs. To prevent fainting, the blood pressure control system senses this change immediately, and rapidly adjusts flow (by increasing heart rate) and resistance to flow (by constricting the blood vessels) to restore blood pressure and maintain brain blood flow. If this system is inadequate, the brain has a backup plan. Blood vessels in the brain can adjust their diameter to keep blood flow constant. If blood pressure drops, the brain blood vessels dilate; if blood pressure increases, the brain blood vessels constrict. This process, which is called autoregulation, allows the brain to maintain a steady stream of oxygen, even when blood pressure changes. We examined what changes in the blood pressure control system or cerebral autoregulation contribute to the blood pressure control problems seen after spaceflight. We asked: (1) does the adaptation to spaceflight cause an adaptation in the blood pressure control system that impairs the ability of the system to constrict blood vessels on return to Earth?; (2) if such a defect exists, could we pinpoint the neural pathways involved?; and (3) does cerebral autoregulation become abnormal during spaceflight, impairing the body s ability to maintain constant brain blood flow when standing upright on Earth? We stressed the blood pressure control system using lower body negative pressure, upright tilt, handgrip exercise, and cold stimulation of the hand. Standard cardiovascular parameters were measured along with sympathetic nerve activity (the nerve activity causing blood vessels to constrict) and brain blood flow. We confirmed that the primary cardiovascular effect of spaceflight was a postflight reduction in upright stroke volume (the amount of blood the heart pumps per beat). Heart rate increased appropriately for the reduction in stroke volume, thereby showing that changes in heart rate regulation alone cannot be responsible for orthostatic hypotension after spaceflight. All of the astronauts in our study had an increase in sympathetic nerve activity during upright tilting on Earth postflight. This increase was well calibrated for the reduction in stroke volume induced by the upright posture. The results obtained from stimulating the sympathetic nervous system using handgrip exercise or cold stress were also entirely normal during and after spaceflight. No astronaut had reduced cerebral blood flow during upright tilt, and cerebral autoregulation was normal or even enhanced inflight. These experiments show that the cardiovascular adaptation to spaceflight does not lead to a defect in the regulation of blood vessel constriction via sympathetic nerve activity. In addition, cerebral autoregulation is well-maintained. It is possible that despite the increased sympathetic nerve activity, blood vessels did not respond with a greater degree of constriction than occurred preflight, possibly uncovering a limit of vasoconstrictor reserve.
Design of H2-O2 space shuttle APU. Volume 1: APU design
NASA Technical Reports Server (NTRS)
Harris, E.
1974-01-01
The H2-O2 space shuttle auxiliary power unit (APU) program is a NASA-Lewis effort aimed at hardware demonstration of the technology required for potential use on the space shuttle. It has been shown that a hydrogen-oxygen power unit (APU) system is an attractive alternate to the space shuttle baseline hydrazine APU system for minimum weight. It has the capability for meeting many of the heat sink requirements for the space shuttle vehicle, thereby reducing the amount of expendable evaporants required for cooling in the baseline APU. Volume 1 of this report covers preliminary design and analysis of the current reference system and detail design of the test version of this reference system. Combustor test results are also included. Volume 2 contains the results of the analysis of an initial version of the reference system and the computer printouts of system performance. The APU consists of subsystems for propellant feed and conditioning, turbopower, and control. Propellant feed and conditioning contains all heat exchangers, valves, and the combustor. The turbopower subsystem contains a two-stage partial-admission pressure-modulated, 400-hp, 63,000-rpm turbine, a 0-to 4-g lubrication system, and a gearbox with output pads for two hydraulic pumps and an alternator (alternator not included on test unit). The electronic control functions include regulation of speed and system temperatures; and start-and-stop sequences, overspeed (rpm) and temperature limits, failsafe provisions, and automatic shutdown provisions.
Practical optimal flight control system design for helicopter aircraft. Volume 1: Technical Report
NASA Technical Reports Server (NTRS)
Hofmann, L. G.; Riedel, S. A.; Mcruer, D.
1980-01-01
A method by which modern and classical theory techniques may be integrated in a synergistic fashion and used in the design of practical flight control systems is presented. A general procedure is developed, and several illustrative examples are included. Emphasis is placed not only on the synthesis of the design, but on the assessment of the results as well.
The report gives results of an emission test of a new municipal solid waste combustor, in Biddeford, ME, that burns refuse-derived fuel and is equipped with a lime spray dryer fabric filter (SD/FF) emission control system. ontrol efficiency of the SD/FF emission control system wa...
NASA Technical Reports Server (NTRS)
Wales, R. O. (Editor)
1981-01-01
The overall mission and spacecraft systems, testing, and operations are summarized. The mechanical subsystems are reviewed, encompassing mechanical design requirements; separation and deployment mechanisms; design and performance evaluation; and the television camera reflector monitor. Thermal control and contamination are discussed in terms of thermal control subsystems, design validation, subsystems performance, the advanced flight experiment, and the quartz-crystal microbalance contamination monitor.
Ates, Selma; Oksuz, Hafıze; Dogu, Bırsen; Bozkus, Fulsen; Ucmak, Hasan; Yanıt, Fadime
2015-01-01
Objectives: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). Methods: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treated in the years 2012-2013 were reviewed, and both the MPV and MPV/PLT rates were evaluated in all groups at Kahramanmaras Sutcu Imam University Intensive Care Unit, Kahramanmaras, Turkey. Results: Statistically significant difference was found between sepsis, SIRS, and control groups when comparing the MPV and MPV/PLT ratio (p<0.05), and no significant difference was found between sepsis and SIRS groups in terms of MPV and MPV/PLT ratio (p>0.05). Mean platelet volume values for sepsis and control groups was 10.07/8.731 femtoliter (fL) (p=0.000), and 9.45/8.731 fL (p=0.000) for SIRS and control groups. In the group of sepsis patients, the MPV was found to be at cut-off 8.915, sensitivity 71%, and specificity 63.9%. In the group of patients with SIRS, MPV was found to be at cut-off 8.85, sensitivity 69.6%, and specificity 62.5%. For the MPV/PLT values, the specificity and sensitivity were found to be insignificant. Conclusion: This study shows that although there was no significant reduction in the PLT values between the sepsis and SIRS patients, the MPV and MPV/PLT ratio values were found to have significant differences. However, the specificity and sensitivity of the values were not reliable standard to be used as a test. PMID:26446329
The 1980 Large space systems technology. Volume 2: Base technology
NASA Technical Reports Server (NTRS)
Kopriver, F., III (Compiler)
1981-01-01
Technology pertinent to large antenna systems, technology related to large space platform systems, and base technology applicable to both antenna and platform systems are discussed. Design studies, structural testing results, and theoretical applications are presented with accompanying validation data. A total systems approach including controls, platforms, and antennas is presented as a cohesive, programmatic plan for large space systems.
Expression of LRRC8/VRAC Currents in Xenopus Oocytes: Advantages and Caveats.
Gaitán-Peñas, Héctor; Pusch, Michael; Estévez, Raúl
2018-03-02
Volume-regulated anion channels (VRACs) play a role in controlling cell volume by opening upon cell swelling. Apart from controlling cell volume, their function is important in many other physiological processes, such as transport of metabolites or drugs, and extracellular signal transduction. VRACs are formed by heteromers of the pannexin homologous protein LRRC8A (also named Swell1) with other LRRC8 members (B, C, D, and E). LRRC8 proteins are difficult to study, since they are expressed in all cells of our body, and the channel stoichiometry can be changed by overexpression, resulting in non-functional heteromers. Two different strategies have been developed to overcome this issue: complementation by transient transfection of LRRC8 genome-edited cell lines, and reconstitution in lipid bilayers. Alternatively, we have used Xenopus oocytes as a simple system to study LRRC8 proteins. Here, we have reviewed all previous experiments that have been performed with VRAC and LRRC8 proteins in Xenopus oocytes. We also discuss future strategies that may be used to perform structure-function analysis of the VRAC in oocytes and other systems, in order to understand its role in controlling multiple physiological functions.
NASA Astrophysics Data System (ADS)
1981-03-01
Support documentation for a second generation heliostat project is presented. Flowcharts of control software are included. Numerical and graphic test results are provided. Project management information is also provided.
The deep space network, volume 16
NASA Technical Reports Server (NTRS)
1973-01-01
The objectives, functions, and organization of the DSN are summarized, and the instrumentation facility, ground communication facility, and the network control system are described. The requirements for supporting planetary flight projects are discussed along with the research and technology for tracking, navigation, network control, and data processing.
DOT National Transportation Integrated Search
2018-05-01
Field evaluation of adaptive signal control technologies (ASCT) is very important in understanding the systems contribution to safety and operational efficiency. Data were collected at six intersections along the Neil Street corridor in Champaign,...
NASA Goddard Space Flight Center Robotic Processing System Program Automation Systems, volume 2
NASA Technical Reports Server (NTRS)
Dobbs, M. E.
1991-01-01
Topics related to robot operated materials processing in space (RoMPS) are presented in view graph form. Some of the areas covered include: (1) mission requirements; (2) automation management system; (3) Space Transportation System (STS) Hitchhicker Payload; (4) Spacecraft Command Language (SCL) scripts; (5) SCL software components; (6) RoMPS EasyLab Command & Variable summary for rack stations and annealer module; (7) support electronics assembly; (8) SCL uplink packet definition; (9) SC-4 EasyLab System Memory Map; (10) Servo Axis Control Logic Suppliers; and (11) annealing oven control subsystem.
1981-10-01
NUMBER(e) Ronald Josephson and Bonnie Sattler 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PRGRAM ELEMENT. PROJECT. TASK San Diego State University... substances ; (2) determining sources and specific points of contamination, survival and growth of pathogens during food service operations; and (3...Control in Atlanta, has recommended (1981) the HACCP system as the best available insurance policy for prevention of foodborne illness in foodservice
Design requirements for SRB production control system. Volume 4: Implementation
NASA Technical Reports Server (NTRS)
1981-01-01
The implementation plan which is presented was developed to provide the means for the successful implementation of the automated production control system. There are three factors which the implementation plan encompasses: detailed planning; phased implementation; and user involvement. The plan is detailed to the task level in terms of necessary activities as the system is developed, refined, installed, and tested. These tasks are scheduled, on a preliminary basis, over a two-and-one-half-year time frame.
The Deep Space Network, volume 17
NASA Technical Reports Server (NTRS)
1973-01-01
The objectives, functions, and organization of the Deep Space Network are summarized. The Deep Space Instrumentation Facility, the Ground Communications Facility, and the Network Control System are described.
40 CFR 51.363 - Quality assurance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test, the evaporative system tests, and emission control component checks (as applicable); (vi...) A check of the Constant Volume Sampler flow calibration; (5) A check for the optimization of the... selection, and power absorption; (9) A check of the system's ability to accurately detect background...
Automation Applications in an Advanced Air Traffic Management System : Volume 1. Summary.
DOT National Transportation Integrated Search
1974-08-01
The Advanced Air Traffic Management System (AATMS) program is a long-range investigation of new concepts and techniques for controlling air traffic and providing services to the growing number of commercial, military, and general aviation users of th...
Tepas, Joseph J; Kerwin, Andrew J; Ra, Jin Hee
2014-03-01
We evaluated the impact on coverage and regional cost of trauma care produced by the activation of a Level II center with no preceding needs analysis in an established trauma region with a Level I center. Patient deidentified trauma registry data for years 2010, 2011, and 2012 were analyzed to assess the effect on trauma service volume during a period at the midpoint of which the Level II center was activated. Trends for each year were evaluated by patient volume, mechanism, resource use as reflected in a transfer to the intensive care unit (ICU) and ICU stay, patient severity as defined by Injury Severity Score (ISS), and patient injury profile determined by mean body region Abbreviated Injury Scale (AIS) score. Between 2010 and 2011, during which the Level II opened, overall volume at the Level I center dropped by 3.7%, and blunt volume remained unchanged. From 2011 to 2012, overall Level I volume dropped by 9.4%, and blunt injury fell by 14%. Proportions requiring immediate operating room or ICU care did not change. ISS distribution at the Level I center across the years was similar. Head, chest, and abdominal injuries, as assessed by AIS body region, increased slightly in severity and decreased in volume by 25%, 17%, and 18%, respectively. For 2012, the new center publically reported treating 1,100 patients, which, in concert with the Level I decrease, translates to increasing regional trauma center access by 25% while increasing expense of necessary core personnel by 217%. Addition of a second trauma center in a stable region, in which injury incidence was actually decreasing, doubled the cost of personnel, one of the most expensive components of the trauma system and decreased the volume of injuries necessary for training and education. Trauma system expansion must be based on needs assessment, which assures system survival and controls societal cost. Economic & value-based evaluation, level III.
Control, communication and monitoring of intravaginal drug delivery in dairy cows.
Cross, Peter S; Künnemeyer, Rainer; Bunt, Craig R; Carnegie, Dale A; Rathbone, Michael J
2004-09-10
We present the design of an electronically controlled drug delivery system. The intravaginally located device is a low-invasive platform that can measure and react inside the cow vagina while providing external control and monitoring ability. The electronics manufactured from off the shelf components occupies 16 mL of a Theratron syringe. A microcontroller reads and logs sensor data and controls a gascell. The generated gas pressure propels the syringe piston and releases the formulation. A two way radio link allows communication between other devices or a base station. Proof of principle experiments confirm variable-rate, arbitrary profile drug delivery qualified by internal sensors. A total volume of 30 mL was dispensed over a 7-day-period with a volume error of +/- 1 mL or +/- 7% for larger volumes. Delivery was controlled or overridden via the wireless link, and proximity to other devices was detected and recorded. The results suggest that temperature and activity sensing or social grouping determined via proximity can be used to detect oestrus and trigger appropriate responses.
NASA Astrophysics Data System (ADS)
Culp, Robert D.; Zietz, Richard P.
The present volume on guidance and control discusses advances in guidance, navigation, and control, guidance and control storyboard displays, space robotic control, spacecraft control and flexible body interaction, and the Mission to Planet Earth. Attention is given to applications of Newton's method to attitude determination, a new family of low-cost momentum/reaction wheels, stellar attitude data handling, and satellite life prediction using propellant quantity measurements. Topics addressed include robust manipulator controller specification and design, implementations and applications of a manipulator control testbed, optimizing transparency in teleoperator architectures, and MIMO system identification using frequency response data. Also discussed are instrument configurations for the restructured Earth Observing System, the HIRIS instrument, clouds and the earth's radiant energy system, and large space-based systems for dealing with global change.
Kramer, H J; Heer, M; Cirillo, M; De Santo, N G
2001-09-01
Renal excretory function and hemodynamics are determined by the effective circulating plasma volume as well as by the interplay of systemic and local vasoconstrictors and vasodilators. Microgravity results in a headward shift of body fluid. Because the control conditions of astronauts were poorly defined in many studies, controversial results have been obtained regarding diuresis and natriuresis as well as renal hemodynamic changes in response to increased central blood volume, especially during the initial phase of space flight. Renal excretory function and renal hemodynamics in microgravity are affected in a complex fashion, because during the initial phase of space flight, variable mechanisms become operative to modulate the effects of increased central blood volume. They include interactions between vasodilators (dopamine, atrial natriuretic peptide, and prostaglandins) and vasoconstrictors (sympathetic nervous system and the renin-angiotensin system). The available data suggest a moderate rise in glomerular filtration rate during the first 2 days after launch without a significant increase in effective renal plasma flow. In contrast, too few data regarding the effects of space flight on renal function during the first 12 hours after launch are available and are, in addition, partly contradictory. Thus, detailed and well-controlled studies are required to shed more light on the role of the various factors besides microgravity that determine systemic and renal hemodynamics and renal excretory function during the different stages of space flight.
Reduction of neuromelanin-positive nigral volume in patients with MSA, PSP and CBD.
Kashihara, Kenichi; Shinya, Takayoshi; Higaki, Fumiyo
2011-01-01
Diseases presenting extrapyramidal symptoms are accompanied by nigral cell loss. In the previous study, we demonstrated the reduction of the neuromelanin-positive volume of substantia nigra (SN) pars compacta (SNc) in patients with Parkinson's disease (PD) using 3-Tesla MRI. In the present study we investigated the neuromelanin-positive SNc volume in patients with the other parkinsonian disorders including multiple system atrophy (MSA), progressive supranuclear palsy (PSP) and corticobasal degeneration (CBD) and compared the results with those with PD, spinocerebellar ataxia (SCA) and controls. Axial T1-weighted (T1W) images were obtained with a 3-Tesla MRI scanner. The border of the neuromelanin-positive region of the SNc was traced manually on these images with a pentablet pointing device and the SNc volume was calculated. The SNc volumes of 28 patients with MSA, 11 patients with PSP and 10 patients with CBD were compared with those of 80 patients with PD, 9 patients with SCA and 54 patients who had suffered mild acute ischemic stroke as controls. The mean volumes for the left and right SN were used for statistical analyses. The volumes of the neuromelanin-positive SNc region in patients with MSA, PSP and CBD, but not SCA were reduced to the same extent as PD patients compared with controls. Reduced volume of the neuromelanin-positive SNc region of patients with MSA, PSP and CBD was detected by neuromelanin MR imaging. Volumetric evaluation of neuromelanin MR imaging may provide a biomarker of nigral degeneration in patients with MSA, PSP and CBD as in patients with PD.
Blumenschein, Nicholas A; Han, Daewoo; Caggioni, Marco; Steckl, Andrew J
2014-06-11
Magnetic beads (MBs) with ∼1.9 μm average diameter were used to transport specific microliter-scale volumes of liquids between adjacent reservoirs within a closed tube under the influence of a magnetic field. The tube's inner surface is coated with a hydrophobic layer, enabling the formation of a surface tension valve by inserting an air gap between reservoirs. This transfer process was implemented by keeping the MBs stationary with a fixed external magnet while the liquid reservoirs were translated by a computer-controlled syringe pump system. The magnet induces the aggregation of MBs in a loosely packed cluster (void volume ∼90-95%) against the tube's inner wall. The liquid trapped in the MB cluster is transported across the air gap between reservoirs. Fluorescence intensity from a dye placed in one reservoir is used to measure the volume of liquid transferred between reservoirs. The carry-over liquid volume is controlled by the mass of the MBs within the device. The typical volume of liquid carried by the MB cluster is ∼2 to 3 μL/mg of beads, allowing the use of small samples. This technique can be used to study the effect of small compositional variation on the properties of fluid mixtures. The feasibility of this "lab-in-tube" approach for binary phase diagram determination in a water-surfactant (C12E5) system was demonstrated.
MSFC Skylab airlock module, volume 1. [systems design and performance
NASA Technical Reports Server (NTRS)
1974-01-01
The history and development of the Skylab Airlock Module and Payload Shroud is presented from initial concept through final design. A summary is given of the Airlock features and systems. System design and performance are presented for the Spent Stage Experiment Support Module, structure and mechanical systems, mass properties, thermal and environmental control systems, EVA/IVA suite system, electrical power system, sequential system, sequential system, and instrumentation system.
Computer Sciences and Data Systems, volume 2
NASA Technical Reports Server (NTRS)
1987-01-01
Topics addressed include: data storage; information network architecture; VHSIC technology; fiber optics; laser applications; distributed processing; spaceborne optical disk controller; massively parallel processors; and advanced digital SAR processors.
NASA Technical Reports Server (NTRS)
Wieland, P. O.
1998-01-01
The International Space Station (ISS) incorporates elements designed and developed by an international consortium led by the United States (U.S.), and by Russia. For this cooperative effort to succeed, it is crucial that the designs and methods of design of the other partners are understood sufficiently to ensure compatibility. Environmental Control and Life Support (ECLS) is one system in which functions are performed independently on the Russian Segment (RS) and on the U.S./international segments. This document describes, in two volumes, the design and operation of the ECLS Systems (ECLSS) on board the ISS. This current volume, Volume 1, is divided into three chapters. Chapter 1 is a general overview of the ISS, describing the configuration, general requirements, and distribution of systems as related to the ECLSS, and includes discussion of the design philosophies of the partners and methods of verification of equipment. Chapter 2 describes the U.S. ECLSS and technologies in greater detail. Chapter 3 describes the ECLSS in the European Attached Pressurized Module (APM), Japanese Experiment Module (JEM), and Italian Mini-Pressurized Logistics Module (MPLM). Volume II describes the Russian ECLSS and technologies in greater detail. These documents present thorough, yet concise, descriptions of the ISS ECLSS.
Reduced limbic and hypothalamic volumes correlate with bone density in early Alzheimer's disease.
Loskutova, Natalia; Honea, Robyn A; Brooks, William M; Burns, Jeffrey M
2010-01-01
Accelerated bone loss is associated with Alzheimer's disease (AD). Although the central nervous system plays a direct role in regulating bone mass, primarily through the actions of the hypothalamus, there is little work investigating the possible role of neurodegeneration in bone loss. In this cross-sectional study, we examined the association between bone mineral density (BMD) and neuroimaging markers of neurodegeneration (i.e., global and regional measures of brain volume) in early AD and non-demented aging. Fifty-five non-demented and 63 early AD participants underwent standard neurological and neuropsychological assessment, structural MRI scanning, and dual energy x-ray absorptiometry. In early AD, voxel-based morphometry analyses demonstrated that low BMD was associated with low volume in limbic grey matter (GM) including the hypothalamus, cingulate, and parahippocampal gyri and in the left superior temporal gyrus and left inferior parietal cortex. No relationship between BMD and regional GM volume was found in non-demented controls. The hypothesis-driven region of interest analysis further isolating the hypothalamus demonstrated a positive relationship between BMD and hypothalamic volume after controlling for age and gender in the early AD group but not in non-demented controls. These results demonstrate that lower BMD is associated with lower hypothalamic volume in early AD, suggesting that central mechanisms of bone remodeling may be disrupted by neurodegeneration.
NASA Technical Reports Server (NTRS)
Jones, A. L.
1972-01-01
Requirements and concepts and the tradeoff analysis leading to the preferred concept are presented. Integrated analyses are given for subsystems and thermal control. Specific tradeoffs and analyses are also given for water management, atmosphere control, energy storage, radiators, navigation, control moment gyros, and system maintenance. The analyses of manipulator concepts and requirements, and supplemental analyses of information management issues are summarized. Subsystem reliability analyses include a detailed discussion of the critical failure analysis.
Integrated orbital servicing study follow-on. Volume 3: Engineering test unit and controls
NASA Technical Reports Server (NTRS)
1978-01-01
A one-g servicing demonstration system which can be used to investigate and develop, in a real time hands-on situation, a wide variety of the mechanism and control system aspects of orbital servicing in the form of module exchange is described including the engineering test unit and the servicer servo drive console. A series of recommendations for future work is given concerning the control problem and more efficient module exchanges, mechanical elements, and electronics.
NASA Technical Reports Server (NTRS)
1981-01-01
The software package evaluation was designed to analyze commercially available, field-proven, production control or manufacturing resource planning management technology and software package. The analysis was conducted by comparing SRB production control software requirements and conceptual system design to software package capabilities. The methodology of evaluation and the findings at each stage of evaluation are described. Topics covered include: vendor listing; request for information (RFI) document; RFI response rate and quality; RFI evaluation process; and capabilities versus requirements.
29 CFR 1910.1029 - Coke oven emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., including at least one sample during each shift for each battery and each job classification within the... controls to control coke oven emissions during charging operations: (a) One of the following methods of...) Aspiration systems designed and operated to provide sufficient negative pressure and flow volume to...
29 CFR 1910.1029 - Coke oven emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., including at least one sample during each shift for each battery and each job classification within the... controls to control coke oven emissions during charging operations: (a) One of the following methods of...) Aspiration systems designed and operated to provide sufficient negative pressure and flow volume to...
29 CFR 1910.1029 - Coke oven emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., including at least one sample during each shift for each battery and each job classification within the... controls to control coke oven emissions during charging operations: (a) One of the following methods of...) Aspiration systems designed and operated to provide sufficient negative pressure and flow volume to...
Satellite Power Systems (SPS) Concept Definition Study. Volume 3: SPS Concept Evolution
NASA Technical Reports Server (NTRS)
Hanley, G.
1978-01-01
A solar photovoltaic satellite based upon the utilization of a GaAlAs solar cell is defined. Topics covered include silicon-based photovoltaics, solar thermal power conversion, microwave energy transmission, power distribution, structures, attitude control and stationkeeping, thermal, and information management and control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wichner, R.P.; Weber, C.F.; Wright, A.L.
1983-09-01
This is the second volume of a two-part study regarding the response of Browns Ferry Unit 1 to a postulated break in the scram discharge volume of the control rod drive hydraulic system immediately following a scram. The material in this second volume pertains to the second aspect of the study, the resultant transport of fission products from their original locations in the fuel to a series of repositories within the primary system, the primary and secondary containment structures, and ultimately the release of a small portion to the environment. Transport models are developed for the noble gases krypton andmore » xenon and for iodine and cesium to describe the release of these fission products from the overheated fuel and their subsequent movement under the conditions predicted to exist in the various repositories during the course of the accident.« less
Reduced Cortical Gray Matter Volume In Male Adolescents With Substance And Conduct Problems
Dalwani, Manish; Sakai, Joseph T.; Mikulich-Gilbertson, Susan K.; Tanabe, Jody; Raymond, Kristen; McWilliams, Shannon K.; Thompson, Laetitia L.; Banich, Marie T.; Crowley, Thomas J.
2011-01-01
Boys with serious conduct and substance problems (“Antisocial Substance Dependence” (ASD)) repeatedly make impulsive and risky decisions in spite of possible negative consequences. Because prefrontal cortex (PFC) is involved in planning behavior in accord with prior rewards and punishments, structural abnormalities in PFC could contribute to a person's propensity to make risky decisions. Methods We acquired high-resolution structural images of 25 male ASD patients (ages 14–18 years) and 19 controls of similar ages using a 3T MR system. We conducted whole-brain voxel-based morphometric analysis (p<0.05, corrected for multiple comparisons at whole-brain cluster-level) using Statistical Parametric Mapping version-5 and tested group differences in regional gray matter (GM) volume with analyses of covariance, adjusting for total GM volume, age, and IQ; we further adjusted between-group analyses for ADHD and depression. As secondary analyses, we tested for negative associations between GM volume and impulsivity within groups and separately, GM volume and symptom severity within patients using whole-brain regression analyses. Results ASD boys had significantly lower GM volume than controls in left dorsolateral PFC (DLPFC), right lingual gyrus and bilateral cerebellum, and significantly higher GM volume in right precuneus. Left DLPFC GM volume showed negative association with impulsivity within controls and negative association with substance dependence severity within patients. Conclusions ASD boys show reduced GM volumes in several regions including DLPFC, a region highly relevant to impulsivity, disinhibition, and decision-making, and cerebellum, a region important for behavioral regulation, while they showed increased GM in precuneus, a region associated with self-referential and self-centered thinking. PMID:21592680
A spacecraft integrated power/attitude control system
NASA Technical Reports Server (NTRS)
Keckler, C. R.; Jacobs, K. L.
1974-01-01
A study to determine the viability and application of a system capable of performing the dual function of power storage/generation and attitude control has been conducted. Results from the study indicate that an integrated power/attitude control system (IPACS) can satisfy future mission requirements while providing significant savings in weight, volume, and cost over conventional systems. A failure-mode configuration of an IPACS was applied to a shuttle-launched RAM free-flyer and simulated using make-do hardware linked to a hybrid computer. Data from the simulation runs indicate that control interactions resulting from heavy power demands have minimal effect on system control effectiveness. The system was shown to be capable of meeting the stringent pointing requirements of 1 arc-second while operating under the influence of an orbital disturbance environment and during periods of momentum variations imposed by energy transfer requirements.
Automotive Stirling Engine Mod 1 Design Review, volume 2
NASA Technical Reports Server (NTRS)
1982-01-01
The auxiliaries and the control system for the ASE MOD I: (1) provide the required fuel and air flows for a well controlled combustion process, generating heat to the Stirling cycle; (2) provide a driver acceptable method for controlling the power output of the engine; (3) provide adequate lubrication and cooling water circulation; (4) generate the electric energy required for engine and vehicle operation; (5) provide a driver acceptable method for starting, stopping and monitoring the engine; and (6) provide a guard system, that protects the engine at component or system malfunction. The control principles and the way the different components and sub-systems interact are described as well as the different auxiliaries, the air fuel system, the power control systems and the electronics. The arrangement and location of auxiliaries and other major components are also examined.
ERIC Educational Resources Information Center
Logistics Management Inst., Washington, DC.
The Federal Aviation Administration of the Department of Transportation controls civilian pilot training. Through its regulations and testing and licensing procedures, the FAA sets minimum criteria for course content and knowledge and skill acquisition. Since few training organizations have the economic resources required to do original research…
1976-06-01
rotating stall control system which was tested both on a low speed rig and a J-85-S engine. The second objective was to perform fundamental studies of the...Stator Stage 89 6 Annular Cascade Configuration Used for Rotating Stall Studies on Rotoi-Stator Stage ..... .............. ... 90 7 Static Pressure Rise...ground tests on a J-8S-S turbojet engine. The work i3 reported in three separate volumes. Volume I entitled, "Basic Studies of Rotating Stall", covers
Effect of prolonged bed rest on lung volume in normal individuals
NASA Technical Reports Server (NTRS)
Beckett, W. S.; Vroman, N. B.; Nigro, D.; Thompson-Gorman, S.; Wilkerson, J. E.
1986-01-01
The effect of prolonged bed rest on the lung function was studied by measuring forced vital capacity (FVC) and total lung capacity (TLC) in normal subjects before, during, and after 11- to 12-day rest periods. It was found that both FVC and TLC increased during bed rest (compared with the ambulatory controls), while residual volume and functional residual capacity of the respiratory system did not change. It is concluded that the increase in TLC by prolonged bed rest is not dependent on alterations in plasma volume.
Research on Volume Measurement System of Weights with Hydrostatic Technique
NASA Astrophysics Data System (ADS)
Wang, Jian; Ren, Xiaoping; Yao, Hong; Cai, Changqing; Zhang, Yue; Zhong, Ruilin; Ding, Jing'an
According to Annex B.7.4 of OIML R111-1, equipment for measuring volume of weights mass ranging from 1 kg to 20 kg including three methods of hydrostatic comparison is described. The equipment consists of a robot arm for transferring weights, a liquid bath, a mass comparator with 26.1 kg of maximum capacity and 1 mg of readability, glass housing, two weight exchangers including in air and in liquid, two weight holders including in air and in liquid, and a controller. The equipment will enable to perform automatically volume measurements.
Urban development control based on transportation carrying capacity
NASA Astrophysics Data System (ADS)
Miharja, M.; Sjafruddin, A. H.
2017-06-01
Severe transportation problems in Indonesian urban areas are stimulated by one fundamental factor, namely lack of awareness on transportation carrying capacity in these areas development control. Urban land use development towards more physical coverage is typically not related with the capability of transportation system to accommodate additional trips volume. Lack of clear connection between development permit with its implication on the transportation side has led to a phenomenon of exceeding transport demand over supply capacity. This paper discusses the concept of urban land use development control which will be related with transport carrying capacity. The discussion would cover both supply and demand sides of transportation. From supply side, the analysis regarding the capacity of transport system would take both existing as well as potential road network capacity could be developed. From demand side, the analysis would be through the control of a maximum floor area and public transport provision. Allowed maximum floor area for development would be at the level of generating traffic at reasonable volume. Ultimately, the objective of this paper is to introduce model to incorporate transport carrying capacity in Indonesian urban land use development control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, B.; Robinson, B.; Mosher, T.
From 1982 through 1986, Philadelphia Electric Company (PECo) hosted the test of a communication system proposed for distribution automation and load management. The system included a utility control center (UCC), a broadcast interface unit in the AM station transmitter, and receiving units. To implement two-way communications, transmitters operating in the VHF spectrum at 154.463750 MHz were coupled with AM receivers. The VHF signal was received by four central receivers installed in the PECo service territory, and communicated to the UCC by either microwave or telephone links. The AM carrier signal provided communications and a synchronous time reference for the communicationmore » system. Station WCAU, 1210 kHz, was the broadcaster for the test. The test results confirmed the effectiveness of the AM broadcast link. However, in this particular implementation, the VHF link fell short of both expectation and acceptablity for return-path communications. The data is summarized and discussed in Volume I, and presented with additional detail in Volume II. A communications system consultant developed analytical models for the AM and VHF signal paths, and analyzed the data with respect to the models. Volume I of the two-volume report describes the communications system in general, presents the major data interpretations and conclusions, and describes the chronology and background for the project. It must be read and understood as a prerequisite for studying the information in Volume II. 14 figs., 1 tab.« less
NASA Astrophysics Data System (ADS)
Fontana, Cristiano Lino; Carnera, Alberto; Lunardon, Marcello; Pino, Felix; Sada, Cinzia; Soramel, Francesca; Stevanato, Luca; Nebbia, Giancarlo; Carasco, Cédric; Perot, Bertrand; Sardet, Alix; Sannie, Guillaume; Iovene, Alessandro; Tintori, Carlo; Grodzicki, Krystian; Moszyński, Marek; Sibczyński, Paweł; Swiderski, Lukasz; Moretto, Sandra
The European project entitled ;effective Container inspection at BORDer control points; (C-BORD) focuses on the development and in-situ tests of a comprehensive cost-effective solution for the generalized Non-Intrusive Inspection (NII) of containers and large-volume freight at the European Union (EU) border. It copes with a large range of targets, including explosives, chemical warfare agents, illicit drugs, tobacco and Special Nuclear Materials. Within the C-BORD project, a new generation of Tagged Neutron Inspection System (TNIS) for cargo containers is foreseen. Unlike its predecessors, this system would be the first Rapidly Relocatable TNIS (RRTNIS). It will be a second-line defense system, to be used on sealed containers in order to detect explosives, illicit drugs and chemical agents in a suspect voxel (elementary volume unit). We report on the status of the RRTNIS system, in particular the overall design, the characterization of the large-volume NaI(Tl) gamma detectors, the digital analysis of the time measurements and the Data Acquisition System (DAQ).
Study of aerodynamic surface control of space shuttle boost and reentry, volume 1
NASA Technical Reports Server (NTRS)
Chang, C. J.; Connor, C. L.; Gill, G. P.
1972-01-01
The optimization technique is described which was used in the study for applying modern optimal control technology to the design of shuttle booster engine reaction control systems and aerodynamic control systems. Complete formulations are presented for both the ascent and reentry portions of the study. These formulations include derivations of the 6D perturbation equations of motion and the process followed in the control and blending law selections. A total hybrid software concept applied to the study is described in detail. Conclusions and recommendations based on the results of the study are included.
NASA Technical Reports Server (NTRS)
1980-01-01
Detailed software and hardware documentation for the Cardiopulmonary Data Acquisition System is presented. General wiring and timing diagrams are given including those for the LSI-11 computer control panel and interface cables. Flowcharts and complete listings of system programs are provided along with the format of the floppy disk file.
Shuttle cryogenic supply system optimization study. Volume 6: Appendixes
NASA Technical Reports Server (NTRS)
1973-01-01
The optimization of the cryogenic supply system for space shuttles is discussed. The subjects considered are: (1) auxiliary power unit parametric data, (2) propellant acquisition, (3) thermal protection and thermodynamic properties, (4) instrumentation and controls, and (5) initial component redundancy evaluations. Diagrams of the systems are provided. Graphs of the performance capabilities are included.
49 CFR 236.1005 - Requirements for Positive Train Control systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be equipped with a PTC system shall be determined and reported as follows: (i) The traffic density... installed, based upon changes in rail traffic such as reductions in total traffic volume or cessation of... review of the requirement to install PTC on a low density track segment where a PTC system is otherwise...
Renal and Cardio-Endocrine Responses in Humans to Simulated Microgravity
NASA Technical Reports Server (NTRS)
Williams, Gordon H.
1999-01-01
The volume regulating systems are integrated to produce an appropriate response to both acute and chronic volume changes. Their responses include changing the levels of the hormones and neural inputs of the involved systems and/or changing the responsiveness of their target tissues. Weightlessness during space travel produces a volume challenge that is unfamiliar to the organism. Thus, it is likely that these volume regulatory mechanisms may respond inappropriately, e.g., a decrease in total body volume in space and abnormal responses to upright posture and stress on return to Earth. A similar "inappropriateness" also can occur in disease states, e.g., congestive heart failure. While it is clear that weightlessness produces profound changes in sodium and volume homeostasis, the mechanisms responsible for these changes are incompletely understood. Confounding this analysis is sleep deprivation, common in space travel, which can also modify volume homeostatic mechanisms. The purpose of this project is to provide the required understanding and then to design appropriate countermeasures to reduce or eliminate the adverse effects of microgravity. To accomplish this we are addressing five Specific Aims: (1) To test the hypothesis that microgravity modifies the acute responsiveness of the renin-angiotensin-aldosterone system (RAAS) and renal blood flow; (2) Does simulated microgravity change the circadian rhythm of the volume- regulating hormones?; (3) Does simulated microgravity change the target tissue responsiveness to angiotensin 11 (AngII)?; (4) Does chronic sleep deprivation modify the circadian rhythm of the RAAS and change the acute responsiveness of this system to posture beyond what a microgravity environment alone does? and (5) What effect does salt restriction have on the volume homeostatic and neurohumoral responses to a microgravity environment? Because the RAAS plays a pivotal role in blood pressure control and volume homeostasis, it likely is a major mediator of the adaptive cardio-renal responses observed during space missions and is a special focus of this project. Thus, the overall goal of this project is to assess the impact of microgravity and sleep deprivation in humans on volume-regulating systems. To achieve this overall objective, we are evaluating renal blood flow and the status and responsiveness of the volume- regulating systems (RAAS, atrial natriuretic peptide and vasopressin), and the adrenergic system (plasma and urine catecholamines) in both simulated microgravity and normal gravity with and -Without sleep deprivation. Furthermore, the responses of the volume homeostatic mechanisms to acute stimulation by upright tilt testing, standing and exercise are being evaluated before and after achieving equilibrium with these interventions.
Long-range interacting systems in the unconstrained ensemble.
Latella, Ivan; Pérez-Madrid, Agustín; Campa, Alessandro; Casetti, Lapo; Ruffo, Stefano
2017-01-01
Completely open systems can exchange heat, work, and matter with the environment. While energy, volume, and number of particles fluctuate under completely open conditions, the equilibrium states of the system, if they exist, can be specified using the temperature, pressure, and chemical potential as control parameters. The unconstrained ensemble is the statistical ensemble describing completely open systems and the replica energy is the appropriate free energy for these control parameters from which the thermodynamics must be derived. It turns out that macroscopic systems with short-range interactions cannot attain equilibrium configurations in the unconstrained ensemble, since temperature, pressure, and chemical potential cannot be taken as a set of independent variables in this case. In contrast, we show that systems with long-range interactions can reach states of thermodynamic equilibrium in the unconstrained ensemble. To illustrate this fact, we consider a modification of the Thirring model and compare the unconstrained ensemble with the canonical and grand-canonical ones: The more the ensemble is constrained by fixing the volume or number of particles, the larger the space of parameters defining the equilibrium configurations.
NASA Technical Reports Server (NTRS)
Agnew, Donald L.; Jones, Peter A.
1989-01-01
A study was conducted to define reasonable and representative LDR system concepts for the purpose of defining a technology development program aimed at providing the requisite technological capability necessary to start LDR development by the end of 1991. This volume presents thirteen technology assessments and technology development plans, as well as an overview and summary of the LDR concepts. Twenty-two proposed augmentation projects are described (selected from more than 30 candidates). The five LDR technology areas most in need of supplementary support are: cryogenic cooling; astronaut assembly of the optically precise LDR in space; active segmented primary mirror; dynamic structural control; and primary mirror contamination control. Three broad, time-phased, five-year programs were synthesized from the 22 projects, scheduled, and funding requirements estimated.
Modeling of energy release systems from OTEC plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denno, K.
1983-12-01
This paper presents analytical scope for the controlling functions of OTEC operation for the ultimate production of sizable bulk ..delta..T as well as H/sub 2/, N/sub 2/ and NH/sub 3/. The controlling parametric functions include the oceanic and ammonia Reynolds numbers which depend implicitly and explicitly on the ocean water velocity, mass-volume, duration of ..delta..T extraction, and the inlet and outlet water temperatures internally and externally. Solutions for the oceanic and amonia Reynolds numbers have been established setting the deciding constraints on water velocity, boundary temperatures, mass-volume as well as other plant parameters. Linkage between OTEC plant and other conventionalmore » as well as advanced energy systems has been expressed in terms of a set of balance and coordinating energy equations.« less
NASA Technical Reports Server (NTRS)
1979-01-01
Contents: project plan summary; project and mission objectives; related studies and technology support activities; technical summary; management; procurement approach; project definition items and schedule; resources; management review; controlled items; and safety, reliability, and quality assurance.
Quiet Clean Short-Haul Experimental Engine (QCSEE). Preliminary analyses and design report, volume 2
NASA Technical Reports Server (NTRS)
1974-01-01
The experimental and flight propulsion systems are presented. The following areas are discussed: engine core and low pressure turbine design; bearings and seals design; controls and accessories design; nacelle aerodynamic design; nacelle mechanical design; weight; and aircraft systems design.
49 CFR 238.403 - Crash energy management.
Code of Federal Regulations, 2010 CFR
2010-10-01
... crash energy management system to dissipate kinetic energy during a collision. The crash energy management system shall provide a controlled deformation and collapse of designated sections within the... resulting from dynamic forces transmitted to occupied volumes. (b) The design of each unit shall consist of...
Klepiszewski, K; Schmitt, T G
2002-01-01
While conventional rule based, real time flow control of sewer systems is in common use, control systems based on fuzzy logic have been used only rarely, but successfully. The intention of this study is to compare a conventional rule based control of a combined sewer system with a fuzzy logic control by using hydrodynamic simulation. The objective of both control strategies is to reduce the combined sewer overflow volume by an optimization of the utilized storage capacities of four combined sewer overflow tanks. The control systems affect the outflow of four combined sewer overflow tanks depending on the water levels inside the structures. Both systems use an identical rule base. The developed control systems are tested and optimized for a single storm event which affects heterogeneously hydraulic load conditions and local discharge. Finally the efficiencies of the two different control systems are compared for two more storm events. The results indicate that the conventional rule based control and the fuzzy control similarly reach the objective of the control strategy. In spite of the higher expense to design the fuzzy control system its use provides no advantages in this case.
1975-11-17
and control (subsystem) COMM., comm AEC Atomic Energy Commission comsat AFB Air Force Base COMSTAR ACE A-hr aerospace ground equipment ampere...array TDA Satellite Assembly Building TDAL Space and Missile Systems Organization (U.S. Air Force) TDM THIR satellite communications system TI...Satellite Control Facility (U.S. Air Force) TIROS selective chopper radiometer TLM, T/M surface composition mapping radiometer TOS TRUST
Orbiter subsystem hardware/software interaction analysis. Volume 8: Forward reaction control system
NASA Technical Reports Server (NTRS)
Becker, D. D.
1980-01-01
The results of the orbiter hardware/software interaction analysis for the AFT reaction control system are presented. The interaction between hardware failure modes and software are examined in order to identify associated issues and risks. All orbiter subsystems and interfacing program elements which interact with the orbiter computer flight software are analyzed. The failure modes identified in the subsystem/element failure mode and effects analysis are discussed.
1990-09-14
expectations tend to follow a set pattern as he sets out an the learning curve for the aplication of distributed processor systems, 3.149 those "new" systems...do the job more efficiently. Another example is the use of aplication software to replace the perfectly adequate Wilt-in logic involved with...combat system survivability. The probability of kill, Pk, of the combat system is shown decreasing from current firepower kill levels to that of mobility
Eicken, Andreas; Michel, Julia; Hager, Alfred; Tanase, Daniel; Kaemmerer, Harald; Cleuziou, Julie; Hess, John; Ewert, Peter
2017-02-01
The atrial baffle repair (ABR) significantly improved the fate of patients with transposition of the great arteries (TGA). However, these patients show impaired exercise tolerance and some present severe decline of systemic ventricular function. Intrinsic myocardial weakness, low heart rate response to exercise and diastolic filling impairment are discussed to be causative. Forty-nine long-term survivors with TGA (median age 23.7 year) after ABR were catheterized with measured oxygen consumption in four conditions (baseline, volume, atrial pacing, dobutamine) and the results were compared to 10 normal controls. Median cardiac output was significantly lower in the ABR group (2.2 vs. 2.6 l/min/m 2 ; p = 0.015), and systemic resistance was significantly elevated (28.9 vs. 22.2 U m 2 ; p = 0.04) in comparison with normals. While stroke volume rose by 27% in the control group, it dropped by 7% in patients after ABR at atrial pacing (80/min). Stroke volume increase after dobutamine was significantly lower after ABR in comparison with normal controls (34 vs. 106%; p = 0.001). Higher NYHA class (p = 0.043), degree of tricuspid regurgitation (p = 0.009) and ventricular function (p = 0.028) were associated with lower stroke volume increase. Limited exercise capability of patients after ABR for TGA is primarily due to limited diastolic filling of the ventricles due to stiff non-compliant atrial pathways. Elevated systemic resistance may lead to severe myocardial hypertrophy with possible ischemia and contribute to the multifactorial decline of ventricular function in some patients.
NASA Technical Reports Server (NTRS)
1973-01-01
A computer programmer's manual for a digital computer which will permit rapid and accurate parametric analysis of current and advanced attitude control propulsion systems is presented. The concept is for a cold helium pressurized, subcritical cryogen fluid supplied, bipropellant gas-fed attitude control propulsion system. The cryogen fluids are stored as liquids under low pressure and temperature conditions. The mathematical model provides a generalized form for the procedural technique employed in setting up the analysis program.
Microwave Power Transmission System Studies. Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
Maynard, O. E.; Brown, W. C.; Edwards, A.; Meltz, G.; Haley, J. T.; Howell, J. M.; Nathan, A.
1975-01-01
A study of microwave power generation, transmission, reception and control was conducted as a part of a program to demonstrate the feasibility of power transmission from geosynchronous orbit. A summary is presented of results concerning design approaches, estimated costs (ROM), critical technology, associated ground and orbital test programs with emphasis on dc to rf conversion, transmitting antenna, phase control, mechanical systems, flight operations, ground power receiving-rectifying antenna with systems analysis, and evaluation. Recommendations for early further in-depth studies complementing the technology program are included.
1984-12-01
3Com Corporation ....... A-18 Ethernet Controller Support . . . . . . A-19 Host Systems Support . . . . . . . . . A-20 Personal Computers Support...A-23 VAX EtherSeries Software 0 * A-23 Network Research Corporation . o o o . o A-24 File Transfer Service . . . . o A-25 Virtual Terminal Service 0...Control office is planning to acquire a Digital Equipment Corporation VAX 11/780 mainframe computer with the Unix Berkeley 4.2BSD operating system. They
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3MW MOD-5A wind turbine generator is documented. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 3, book 2 describes the performance and characteristics of the MOD-5A wind turbine generator in its final configuration. The subsystem for power generation, control, and instrumentation subsystems is described in detail. The manufacturing and construction plans, and the preparation of a potential site on Oahu, Hawaii, are documented. The quality assurance and safety plan, and analyses of failure modes and effects, and reliability, availability and maintainability are presented.
1990-09-14
transmission of detected variations through sound lines of communication to centrally located standard Navy computers . These computers would be programmed to...have been programmed in C language. The program runs under the operating system ,OS9 on a VME-bus computer with a 68000 microprocessor. A number of full...present practice of"add-on" supervisory controls during ship design and construction,and "fix-it" R&D programs implemented after the ship isoperational
Space shuttle main engine definition (phase B). Volume 2: Avionics. [for space shuttle
NASA Technical Reports Server (NTRS)
1971-01-01
The advent of the space shuttle engine with its requirements for high specific impulse, long life, and low cost have dictated a combustion cycle and a closed loop control system to allow the engine components to run close to operating limits. These performance requirements, combined with the necessity for low operational costs, have placed new demands on rocket engine control, system checkout, and diagnosis technology. Based on considerations of precision environment, and compatibility with vehicle interface commands, an electronic control, makes available many functions that logically provide the information required for engine system checkout and diagnosis.
Gong, Jian; Kim, Chang-Jin “CJ”
2009-01-01
Electrowetting-on-dielectric (EWOD) actuation enables digital (or droplet) microfluidics where small packets of liquids are manipulated on a two-dimensional surface. Due to its mechanical simplicity and low energy consumption, EWOD holds particular promise for portable systems. To improve volume precision of the droplets, which is desired for quantitative applications such as biochemical assays, existing practices would require near-perfect device fabricaion and operation conditions unless the droplets are generated under feedback control by an extra pump setup off of the chip. In this paper, we develop an all-electronic (i.e., no ancillary pumping) real-time feedback control of on-chip droplet generation. A fast voltage modulation, capacitance sensing, and discrete-time PID feedback controller are integrated on the operating electronic board. A significant improvement is obtained in the droplet volume uniformity, compared with an open loop control as well as the previous feedback control employing an external pump. Furthermore, this new capability empowers users to prescribe the droplet volume even below the previously considered minimum, allowing, for example, 1:x (x < 1) mixing, in comparison to the previously considered n:m mixing (i.e., n and m unit droplets). PMID:18497909
Gong, Jian; Kim, Chang-Jin C J
2008-06-01
Electrowetting-on-dielectric (EWOD) actuation enables digital (or droplet) microfluidics where small packets of liquids are manipulated on a two-dimensional surface. Due to its mechanical simplicity and low energy consumption, EWOD holds particular promise for portable systems. To improve volume precision of the droplets, which is desired for quantitative applications such as biochemical assays, existing practices would require near-perfect device fabrication and operation conditions unless the droplets are generated under feedback control by an extra pump setup off of the chip. In this paper, we develop an all-electronic (i.e., no ancillary pumping) real-time feedback control of on-chip droplet generation. A fast voltage modulation, capacitance sensing, and discrete-time PID feedback controller are integrated on the operating electronic board. A significant improvement is obtained in the droplet volume uniformity, compared with an open loop control as well as the previous feedback control employing an external pump. Furthermore, this new capability empowers users to prescribe the droplet volume even below the previously considered minimum, allowing, for example, 1 : x (x < 1) mixing, in comparison to the previously considered n : m mixing (i.e., n and m unit droplets).
Condensate Recycling in Closed Plant Growth Chambers
NASA Technical Reports Server (NTRS)
Bledsoe, J. O.; Sager, J. C.; Fortson, R. E.
1994-01-01
Water used in the the Controlled Ecological Life Support System (CELSS) Breadboard Project at the Kennedy Space Center is being recycled. Condensation is collected in the air ducts, filtered and deionized, and resupplied to the system for nutrient solutions, supplemental humidification, solvents and diluents. While the system functions well from a process control standpoint, precise and accurate tracking of water movement through the system to answer plant physiological questions is not consistent. Possible causes include hardware errors, undetected vapor loss from chamber leakage, and unmeasured changes in water volume in the plant growth trays.
DOT National Transportation Integrated Search
1974-08-01
The technical report presents a detailed description of the strategic control functional objectives, followed by a presentation of the basic strategic control algorithm and how it evolved. Contained in this discussion are the results of analyses that...
DOT National Transportation Integrated Search
1995-01-01
Given the 1988 directive, the OPS conducted a study on the potential for EFRDs : to minimize the volume of pipeline spills. They concluded that Remote Controlled Valves : (RCVs) and check valves are the only EFRDs that are effective on hazardous liqu...
Orbital construction demonstration study. Volume 2: Technical
NASA Technical Reports Server (NTRS)
1977-01-01
The following items are discussed in reference to OCDA requirements; (1) flight mechanics and control, (2) effects of sun angle, (3) disturbance torques, (4) control system requirements, (5) OCDA orbit decay profile, and (6) aerodynamic drag forces. Structural design requirements are also given as well as basic design definition.
DOT National Transportation Integrated Search
1977-12-01
Consideration is given to the properties of solid-state circuits, miniature relays and large gravity-operated relays when applied to control systems for grade crossings equipped with train-activated motorist warnings. Factors discussed include origin...
NASA Technical Reports Server (NTRS)
1973-01-01
The probe bus and orbiter subsystems are defined, and tradeoffs analyzed. Subsystems discussed include: communications, electric power, data handling, attitude determination and control, propulsion, thermal control, structure and mechanisms, NASA/ESRO orbiter interface, mission operation, and flight support.
System decontamination as a tool to control radiation fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riess, R.; Bertholdt, H.O.
1995-03-01
Since chemical decontamination of the Reactor Coolant Systems (RCS) and subsystems has the highest potential to reduce radiation fields in a short term this technology has gained an increasing importance. The available decontamination process at Siemens, i.e., the CORD processes, will be described. It is characterized by using permanganic acid for preoxidation and diluted organic acid for the decontamination step. It is a regenerative process resulting in very low waste volumes. This technology has been used frequently in Europe and Japan in both RCS and subsystems. An overview will be given i.e. on the 1993 applications. This overview will includemore » plant, scope, date of performance, system volume specal features of the process removed activities, decon factor time, waste volumes, and personnel dose during decontamination. This overview will be followed by an outlook on future developments in this area.« less
Crustal deformation and source models of the Yellowstone volcanicfield from geodetic data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasco, D.W.; Puskas, C.M.; Smith, R.B.
2006-07-05
Geodetic observations, comprised of InterferometricSynthetic Aperture Radar (InSAR), Global Positioning System (GPS). andleveling measurements, are used to infer volume change in the subsurfaceassociated with the Yellowstone volcanic system. We find that existingfaults play a significant role in controlling subsurface volume increasesand decreases due to fluid migration within the volcanic system. Forexample, subsidence from 1992 to 1995 appears to be associated withvolume changes below the Elephant Back fault zone and a north-southtrending fault which cuts across the caldera. Furthermore, we are able toimage an episode of magma intrusion near the northern edge of the calderawhich parallels and is adjacent to themore » north trending volume decrease.The primary intrusion occurred between 1996 and 2000, though theintrusion appears to have continnued, shallowed, and changed shapebetween 2000 and 2001. There is evidence that the intrusive activityaffected extensional fauts to the north of the caldera.« less
Control of a HexaPOD treatment couch for robot-assisted radiotherapy.
Hermann, Christian; Ma, Lei; Wilbert, Jürgen; Baier, Kurt; Schilling, Klaus
2012-10-01
Moving tumors, for example in the vicinity of the lungs, pose a challenging problem in radiotherapy, as healthy tissue should not be irradiated. Apart from gating approaches, one standard method is to irradiate the complete volume within which a tumor moves plus a safety margin containing a considerable volume of healthy tissue. This work deals with a system for tumor motion compensation using the HexaPOD® robotic treatment couch (Medical Intelligence GmbH, Schwabmünchen, Germany). The HexaPOD, carrying the patient during treatment, is instructed to perform translational movements such that the tumor motion, from the beams-eye view of the linear accelerator, is eliminated. The dynamics of the HexaPOD are characterized by time delays, saturations, and other non-linearities that make the design of control a challenging task. The focus of this work lies on two control methods for the HexaPOD that can be used for reference tracking. The first method uses a model predictive controller based on a model gained through system identification methods, and the second method uses a position control scheme useful for reference tracking. We compared the tracking performance of both methods in various experiments with real hardware using ideal reference trajectories, prerecorded patient trajectories, and human volunteers whose breathing motion was compensated by the system.
Spieth, Peter M; Güldner, Andreas; Uhlig, Christopher; Bluth, Thomas; Kiss, Thomas; Schultz, Marcus J; Pelosi, Paolo; Koch, Thea; Gama de Abreu, Marcelo
2014-05-02
General anesthesia usually requires mechanical ventilation, which is traditionally accomplished with constant tidal volumes in volume- or pressure-controlled modes. Experimental studies suggest that the use of variable tidal volumes (variable ventilation) recruits lung tissue, improves pulmonary function and reduces systemic inflammatory response. However, it is currently not known whether patients undergoing open abdominal surgery might benefit from intraoperative variable ventilation. The PROtective VARiable ventilation trial ('PROVAR') is a single center, randomized controlled trial enrolling 50 patients who are planning for open abdominal surgery expected to last longer than 3 hours. PROVAR compares conventional (non-variable) lung protective ventilation (CV) with variable lung protective ventilation (VV) regarding pulmonary function and inflammatory response. The primary endpoint of the study is the forced vital capacity on the first postoperative day. Secondary endpoints include further lung function tests, plasma cytokine levels, spatial distribution of ventilation assessed by means of electrical impedance tomography and postoperative pulmonary complications. We hypothesize that VV improves lung function and reduces systemic inflammatory response compared to CV in patients receiving mechanical ventilation during general anesthesia for open abdominal surgery longer than 3 hours. PROVAR is the first randomized controlled trial aiming at intra- and postoperative effects of VV on lung function. This study may help to define the role of VV during general anesthesia requiring mechanical ventilation. Clinicaltrials.gov NCT01683578 (registered on September 3 3012).
Impact of Volume Management on Volume Overload and Rehospitalization in CAPD Patients.
Xu, Yi; Yang, Shen-Min; Wang, Xiao-Hua; Wang, Hai-Fang; Niu, Mei-E; Yang, Yi-Qun; Lu, Guo-Yuan; Pang, Jian-Hong; Wang, Fei; Li, Lin
2018-05-01
Heart failure due to volume overload is a major reason for rehospitalization in continuous ambulatory peritoneal dialysis patients. Strict volume control provides better cardiac functions and blood pressure in this population. Volume management, which is a volume control strategy, may decrease volume overload and related complications. Using a quasi-experimental design, 66 continuous ambulatory peritoneal dialysis patients were randomly assigned to the intervention group ( n = 34) and control group ( n = 32). The patients were followed up for 6 months with scheduled clinic and/or telephone visits; the intervention group adopted volume management strategy, while the control group adopted conventional care. Volume overload and cardiac function were compared between the two groups at the baseline and at 6 months. At Month 6, the intervention group resulted in significant improvement in volume overloaded status, cardiac function, and volume-overload-related rehospitalization. Volume management strategy allows for better control of volume overload and is associated with fewer volume-related readmissions.
Lee, Kevin S; Boccazzi, Paolo; Sinskey, Anthony J; Ram, Rajeev J
2011-05-21
This work reports on an instrument capable of supporting automated microscale continuous culture experiments. The instrument consists of a plastic-PDMS device capable of continuous flow without volume drift or evaporation. We apply direct computer controlled machining and chemical bonding fabrication for production of fluidic devices with a 1 mL working volume, high oxygen transfer rate (k(L)a≈0.025 s(-1)), fast mixing (2 s), accurate flow control (±18 nL), and closed loop control over temperature, cell density, dissolved oxygen, and pH. Integrated peristaltic pumps and valves provide control over input concentrations and allow the system to perform different types of cell culture on a single device, such as batch, chemostat, and turbidostat continuous cultures. Continuous cultures are demonstrated without contamination for 3 weeks in a single device and both steady state and dynamically controlled conditions are possible. © The Royal Society of Chemistry 2011
Marusich, Laura R; Bakdash, Jonathan Z; Onal, Emrah; Yu, Michael S; Schaffer, James; O'Donovan, John; Höllerer, Tobias; Buchler, Norbou; Gonzalez, Cleotilde
2016-03-01
We investigated how increases in task-relevant information affect human decision-making performance, situation awareness (SA), and trust in a simulated command-and-control (C2) environment. Increased information is often associated with an improvement of SA and decision-making performance in networked organizations. However, previous research suggests that increasing information without considering the task relevance and the presentation can impair performance. We used a simulated C2 task across two experiments. Experiment 1 varied the information volume provided to individual participants and measured the speed and accuracy of decision making for task performance. Experiment 2 varied information volume and information reliability provided to two participants acting in different roles and assessed decision-making performance, SA, and trust between the paired participants. In both experiments, increased task-relevant information volume did not improve task performance. In Experiment 2, increased task-relevant information volume reduced self-reported SA and trust, and incorrect source reliability information led to poorer task performance and SA. These results indicate that increasing the volume of information, even when it is accurate and task relevant, is not necessarily beneficial to decision-making performance. Moreover, it may even be detrimental to SA and trust among team members. Given the high volume of available and shared information and the safety-critical and time-sensitive nature of many decisions, these results have implications for training and system design in C2 domains. To avoid decrements to SA, interpersonal trust, and decision-making performance, information presentation within C2 systems must reflect human cognitive processing limits and capabilities. © 2016, Human Factors and Ergonomics Society.
Zheng, Yefeng; Barbu, Adrian; Georgescu, Bogdan; Scheuering, Michael; Comaniciu, Dorin
2008-11-01
We propose an automatic four-chamber heart segmentation system for the quantitative functional analysis of the heart from cardiac computed tomography (CT) volumes. Two topics are discussed: heart modeling and automatic model fitting to an unseen volume. Heart modeling is a nontrivial task since the heart is a complex nonrigid organ. The model must be anatomically accurate, allow manual editing, and provide sufficient information to guide automatic detection and segmentation. Unlike previous work, we explicitly represent important landmarks (such as the valves and the ventricular septum cusps) among the control points of the model. The control points can be detected reliably to guide the automatic model fitting process. Using this model, we develop an efficient and robust approach for automatic heart chamber segmentation in 3-D CT volumes. We formulate the segmentation as a two-step learning problem: anatomical structure localization and boundary delineation. In both steps, we exploit the recent advances in learning discriminative models. A novel algorithm, marginal space learning (MSL), is introduced to solve the 9-D similarity transformation search problem for localizing the heart chambers. After determining the pose of the heart chambers, we estimate the 3-D shape through learning-based boundary delineation. The proposed method has been extensively tested on the largest dataset (with 323 volumes from 137 patients) ever reported in the literature. To the best of our knowledge, our system is the fastest with a speed of 4.0 s per volume (on a dual-core 3.2-GHz processor) for the automatic segmentation of all four chambers.
NASA Technical Reports Server (NTRS)
1974-01-01
The technical aspects of the Skylab-Orbital Workshop are discussed. Original concepts, goals, design philosophy, hardware, and testing are reported. The final flight configuration, overall test program, and mission performance are analyzed. The systems which are examined are: (1) the structural system, (2) the meteoroid shield systems, and (3) the environmental/thermal control subsystem.
Sex differences in the correlation of emotional control and amygdala volumes in adolescents.
Blanton, Rebecca E; Chaplin, Tara M; Sinha, Rajita
2010-10-06
We examined male and female adolescents (8-18 years of age) that were scanned with structural brain MRI and looked for a correlation between volume of the right or the left amygdala and parent-reported ability of emotional control. A sex difference was found in the correlation between emotional control and the corrected volume of the left amygdala (that is the amygdala volume adjusted for total cranial volume). In girls, smaller left amygdala volumes were associated with better emotional control. In boys, larger left amygdala volumes were associated with better emotional control. These findings suggest that healthy girls and boys show a difference in the correlation between parental reports of emotional control and the left amygdala volume.
NASA Tech Briefs, August 2002. Volume 26, No. 8
NASA Technical Reports Server (NTRS)
2002-01-01
Topics include: a technology focus on computers, electronic components and systems, software, materials, mechanics, machinery/automation, manufacturing, physical sciences, information sciences, book and reports, and Motion control Tech Briefs.
Huang, Man-li; Wei, Ning; Hu, Jian-bo; Xu, Yi
2008-09-01
To investigate the effects of androgen on sexually dimorphism nucleus in preoptic area (SDN-POA) and anteroventral periventricular nucleus (AVPV) before sexual differentiation of the brain in female rats. Neonatal female SD rats (n=12) were randomly divided into two groups: androgen group and control group. Twenty-four hours after birth animals were subjected to intraperitoneal injection of 50 microl of testosterone propionate (TP,10.0 g/L) or aseptic oil as control. The rats were sacrificed 60 days after the injection and the brains were collected for crystal violet staining. LEICA Q Win system was applied in detecting the boundaries of SDN-POA and AVPV, then the volumes of SDN-POA and AVPV were calculated. The volumes of SDN-POA in androgen group were significantly larger than those in control group [(16.77+/-2.68) vs (8.99+/-1.42)mm(3)x10(-3), P<0.01], while the volumes of AVPV in androgen group were significantly smaller than those in control group [(9.14+/-1.16) vs (14.62+/-2.80)mm(3)x10(-3), P<0.01]. Exogenous androgen rendered before sexual differentiation in female rats results in enlargement of SDN-POA volumes and reduction of AVPV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loong, H.; Liang, C.C.; Tseng, K.T.
1988-01-01
The use of microcomputer control system to gas-fired kiln not only enhanced the porcelain kiln's productivity from 75% to 95% but also saved its operation cost around US$ 200,000 per year. The self-designed microcomputer control system can simultaneous set and control the firing conditions of the period kiln which was built up in our laboratory. Our period kiln having volume of 4 M/sup 3/ was insulated by ceramic fiber which is different from use of refractory in traditional kilns. At the bottom of the kiln is an off-gas tunnel connected with a chimney. Besides the auto start-up and continuous operationmore » of kiln, the main functions of this microcomputer control system are summarized.« less
Orthostatic stress is necessary to maintain the dynamic range of cardiovascular control in space
NASA Technical Reports Server (NTRS)
Baisch, J. F.; Wolfram, G.; Beck, L.; Drummer, C.; Stormer, I.; Buckey, J.; Blomqvist, G.
2000-01-01
In the upright position, gravity fills the low-pressure systems of human circulation with blood and interstitial fluid in the sections below the diaphragm. Without gravity one pressure component in the vessels disappears and the relationship between hydrostatic pressure and oncotic pressure, which regulates fluid passage across the capillary endothelium in the terminal vascular bed, shifts constantly. The visible consequences of this are a puffy face and "bird" legs. The plasma volume shrinks in space and the range of cardiovascular control is reduced. When they stand up for the first time after landing, 30-50% of astronauts suffer from orthostatic intolerance. It remains unclear whether microgravity impairs cardiovascular reflexes, or whether it is the altered volume status that causes the cardiovascular instability following space flight. Lower body negative pressure was used in several space missions to stimulate the cardiovascular reflexes before, during and after a space flight. The results show that cardiovascular reflexes are maintained in microgravity. However, the astronauts' volume status changed in space, towards a volume-retracted state, as measurements of fluid-regulating hormones have shown. It can be hypothesized that the control of circulation and body fluid homeostasis in humans is adapted to their upright posture in the Earth's gravitational field. Autonomic control regulates fluid distribution to maintain the blood pressure in that posture, which most of us have to cope with for two-thirds of the day. A determined amount of interstitial volume is necessary to maintain the dynamic range of cardiovascular control in the upright posture; otherwise orthostatic intolerance may occur more often.
Noise in Nonlinear Dynamical Systems 3 Volume Paperback Set
NASA Astrophysics Data System (ADS)
Moss, Frank; McClintock, P. V. E.
2011-11-01
Volume 1: List of contributors; Preface; Introduction to volume one; 1. Noise-activated escape from metastable states: an historical view Rolf Landauer; 2. Some Markov methods in the theory of stochastic processes in non-linear dynamical systems R. L. Stratonovich; 3. Langevin equations with coloured noise J. M. Sancho and M. San Miguel; 4. First passage time problems for non-Markovian processes Katja Lindenberg, Bruce J. West and Jaume Masoliver; 5. The projection approach to the Fokker-Planck equation: applications to phenomenological stochastic equations with coloured noises Paolo Grigolini; 6. Methods for solving Fokker-Planck equations with applications to bistable and periodic potentials H. Risken and H. D. Vollmer; 7. Macroscopic potentials, bifurcations and noise in dissipative systems Robert Graham; 8. Transition phenomena in multidimensional systems - models of evolution W. Ebeling and L. Schimansky-Geier; 9. Coloured noise in continuous dynamical systems: a functional calculus approach Peter Hanggi; Appendix. On the statistical treatment of dynamical systems L. Pontryagin, A. Andronov and A. Vitt; Index. Volume 2: List of contributors; Preface; Introduction to volume two; 1. Stochastic processes in quantum mechanical settings Ronald F. Fox; 2. Self-diffusion in non-Markovian condensed-matter systems Toyonori Munakata; 3. Escape from the underdamped potential well M. Buttiker; 4. Effect of noise on discrete dynamical systems with multiple attractors Edgar Knobloch and Jeffrey B. Weiss; 5. Discrete dynamics perturbed by weak noise Peter Talkner and Peter Hanggi; 6. Bifurcation behaviour under modulated control parameters M. Lucke; 7. Period doubling bifurcations: what good are they? Kurt Wiesenfeld; 8. Noise-induced transitions Werner Horsthemke and Rene Lefever; 9. Mechanisms for noise-induced transitions in chemical systems Raymond Kapral and Edward Celarier; 10. State selection dynamics in symmetry-breaking transitions Dilip K. Kondepudi; 11. Noise in a ring-laser gyroscope K. Vogel, H. Risken and W. Schleich; 12. Control of noise and applications to optical systems L. A. Lugiato, G. Broggi, M. Merri and M. A. Pernigo; 13. Transition probabilities and spectral density of fluctuations of noise driven bistable systems M. I. Dykman, M. A. Krivoglaz and S. M. Soskin; Index. Volume 3: List of contributors; Preface; Introduction to volume three; 1. The effects of coloured quadratic noise on a turbulent transition in liquid He II J. T. Tough; 2. Electrohydrodynamic instability of nematic liquid crystals: growth process and influence of noise S. Kai; 3. Suppression of electrohydrodynamic instabilities by external noise Helmut R. Brand; 4. Coloured noise in dye laser fluctuations R. Roy, A. W. Yu and S. Zhu; 5. Noisy dynamics in optically bistable systems E. Arimondo, D. Hennequin and P. Glorieux; 6. Use of an electronic model as a guideline in experiments on transient optical bistability W. Lange; 7. Computer experiments in nonlinear stochastic physics Riccardo Mannella; 8. Analogue simulations of stochastic processes by means of minimum component electronic devices Leone Fronzoni; 9. Analogue techniques for the study of problems in stochastic nonlinear dynamics P. V. E. McClintock and Frank Moss; Index.
Controlled differential pressure system for an enhanced fluid blending apparatus
Hallman, Jr., Russell Louis
2009-02-24
A system and method for producing a controlled blend of two or more fluids. Thermally-induced permeation through a permeable tube is used to mix a first fluid from outside the tube with a second fluid flowing through the tube. Mixture ratios may be controlled by adjusting the temperature of the first fluid or by adjusting the pressure drop through the permeable tube. The combination of a back pressure control valve and a differential regulator is used to control the output pressure of the blended fluid. The combination of the back pressure control valve and differential regulator provides superior flow control of the second dry gas. A valve manifold system may be used to mix multiple fluids, and to adjust the volume of blended fluid produced, and to further modify the mixture ratio.
Literature Review of Low Impact Development for Stormwater Control
2015-05-30
appropriate LID technology can be selected to capture the targeted vi metal pollutant. Little information exists on the effects of field variables such as...loading rates and volume, temperature , climate, pH, sediments, organics, and maintenance cycles on systems in the field. 4. The amount of research...maximum extent technically feasible, the pre-development hydrology of the property with regard to the temperature , rate, volume, and duration of flow
Apparatus Tests Peeling Of Bonded Rubbery Material
NASA Technical Reports Server (NTRS)
Crook, Russell A.; Graham, Robert
1996-01-01
Instrumented hydraulic constrained blister-peel apparatus obtains data on degree of bonding between specimen of rubbery material and rigid plate. Growth of blister tracked by video camera, digital clock, pressure transducer, and piston-displacement sensor. Cylinder pressure controlled by hydraulic actuator system. Linear variable-differential transformer (LVDT) and float provide second, independent measure of change in blister volume used as more precise volume feedback in low-growth-rate test.
Bone Balance within a Cortical BMU: Local Controls of Bone Resorption and Formation
Smith, David W.; Gardiner, Bruce S.; Dunstan, Colin
2012-01-01
Maintaining bone volume during bone turnover by a BMU is known as bone balance. Balance is required to maintain structural integrity of the bone and is often dysregulated in disease. Consequently, understanding how a BMU controls bone balance is of considerable interest. This paper develops a methodology for identifying potential balance controls within a single cortical BMU. The theoretical framework developed offers the possibility of a directed search for biological processes compatible with the constraints of balance control. We first derive general control constraint equations and then introduce constitutive equations to identify potential control processes that link key variables that describe the state of the BMU. The paper describes specific local bone volume balance controls that may be associated with bone resorption and bone formation. Because bone resorption and formation both involve averaging over time, short-term fluctuations in the environment are removed, leaving the control systems to manage deviations in longer-term trends back towards their desired values. The length of time for averaging is much greater for bone formation than for bone resorption, which enables more filtering of variability in the bone formation environment. Remarkably, the duration for averaging of bone formation may also grow to control deviations in long-term trends of bone formation. Providing there is sufficient bone formation capacity by osteoblasts, this leads to an extraordinarily robust control mechanism that is independent of either osteoblast number or the cellular osteoid formation rate. A complex picture begins to emerge for the control of bone volume. Different control relationships may achieve the same objective, and the ‘integration of information’ occurring within a BMU may be interpreted as different sets of BMU control systems coming to the fore as different information is supplied to the BMU, which in turn leads to different observable BMU behaviors. PMID:22844401
NASA Astrophysics Data System (ADS)
Chang, C. L.; Chen, C. Y.; Sung, C. C.; Liou, D. H.
This study presents a novel fuel sensor-less control scheme for a liquid feed fuel cell system that does not rely on a fuel concentration sensor. The proposed approach simplifies the design and reduces the cost and complexity of a liquid feed fuel cell system, and is especially suited to portable power sources, of which the volume and weight are important. During the reaction of a fuel cell, the cell's operating characteristics, such as potential, current and power are measured to control the supply of fuel and regulate its concentration to optimize performance. Experiments were conducted to verify that the fuel sensor-less control algorithm is effective in the liquid feed fuel cell system.
Integrated air revitalization system for Space Station
NASA Technical Reports Server (NTRS)
Boyda, R. B.; Miller, C. W.; Schwartz, M. R.
1986-01-01
Fifty-one distinct functions are encompassed by the Space Station's Environmental Control and Life Support System; one exception to this noninteractivity of functions is the regenerative air revitalization system that removes and reduces CO2 and generates O2. The integration of these interdependent functions, and of humidity control, into a single system furnishes opportunities for process simplification as well as for power, weight and volume requirement reductions by comparison with discrete subsystems. Attention is presently given to a system which quantifies these integration-related savings and identifies additional advantages that accrue to this integrating design method.
Pistón, Mariela; Dol, Isabel
2006-01-01
A multiparametric flow system based on multicommutation and binary sampling has been designed for the automated determination of sodium, potassium, calcium, and magnesium in large-volume parenteral solutions and hemodialysis concentrated solutions. The goal was to obtain a computer-controlled system capable of determining the four metals without extensive modifications. The system involved the use of five solenoid valves under software control, allowing the establishment of the appropriate flow conditions for each analyte, that is, sample size, dilution, reagent addition, and so forth. Detection was carried out by either flame atomic emission spectrometry (sodium, potassium) or flame atomic absorption spectrometry (calcium, magnesium). The influence of several operating parameters was studied. Validation was carried out by analyzing artificial samples. Figures of merit obtained include linearity, accuracy, precision, and sampling frequency. Linearity was satisfactory: sodium, r 2 >0.999 ( 0.5 – 3.5 g/L), potassium, r 2 >0.996 (50–150 mg/L), calcium, r 2 >0.999 (30–120 mg/L), and magnesium, r 2 >0.999 (20–40 mg/L). Precision ( s r , %, n=5 ) was better than 2.1 %, and accuracy (evaluated through recovery assays) was in the range of 99.8 %– 101.0 % (sodium), 100.8 – 102.5 % (potassium), 97.3 %– 101.3 % (calcium), and 97.1 %– 99.8 % (magnesium). Sampling frequencies ( h −1 ) were 70 (sodium), 75 (potassium), 70 (calcium), and 58 (magnesium). According to the results obtained, the use of an automated multiparametric system based on multicommutation offers several advantages for the quality control of large-volume parenteral solutions and hemodialysis concentrated solutions. PMID:17671619
Image-guided positioning and tracking.
Ruan, Dan; Kupelian, Patrick; Low, Daniel A
2011-01-01
Radiation therapy aims at maximizing tumor control while minimizing normal tissue complication. The introduction of stereotactic treatment explores the volume effect and achieves dose escalation to tumor target with small margins. The use of ablative irradiation dose and sharp dose gradients requires accurate tumor definition and alignment between patient and treatment geometry. Patient geometry variation during treatment may significantly compromise the conformality of delivered dose and must be managed properly. Setup error and interfraction/intrafraction motion are incorporated in the target definition process by expanding the clinical target volume to planning target volume, whereas the alignment between patient and treatment geometry is obtained with an adaptive control process, by taking immediate actions in response to closely monitored patient geometry. This article focuses on the monitoring and adaptive response aspect of the problem. The term "image" in "image guidance" will be used in a most general sense, to be inclusive of some important point-based monitoring systems that can be considered as degenerate cases of imaging. Image-guided motion adaptive control, as a comprehensive system, involves a hierarchy of decisions, each of which balances simplicity versus flexibility and accuracy versus robustness. Patient specifics and machine specifics at the treatment facility also need to be incorporated into the decision-making process. Identifying operation bottlenecks from a system perspective and making informed compromises are crucial in the proper selection of image-guidance modality, the motion management mechanism, and the respective operation modes. Not intended as an exhaustive exposition, this article focuses on discussing the major issues and development principles for image-guided motion management systems. We hope these information and methodologies will facilitate conscientious practitioners to adopt image-guided motion management systems accounting for patient and institute specifics and to embrace advances in knowledge and new technologies subsequent to the publication of this article.
NASA Technical Reports Server (NTRS)
Montoya, R. J.; Jai, A. R.; Parker, C. D.
1979-01-01
A ground based, general purpose, real time, digital control system simulator (CSS) is specified, developed, and integrated with the existing instrumentation van of the testing facility. This CSS is built around a PDP-11/55, and its operational software was developed to meet the dual goal of providing the immediate capability to represent the F-18 drop model control laws and the flexibility for expansion to represent more complex control laws typical of control configured vehicles. Overviews of the two CSS's developed are reviewed as well as the overall system after their integration with the existing facility. Also the latest version of the F-18 drop model control laws (REV D) is described and the changes needed for its incorporation in the digital and analog CSS's are discussed.
A grid generation system for multi-disciplinary design optimization
NASA Technical Reports Server (NTRS)
Jones, William T.; Samareh-Abolhassani, Jamshid
1995-01-01
A general multi-block three-dimensional volume grid generator is presented which is suitable for Multi-Disciplinary Design Optimization. The code is timely, robust, highly automated, and written in ANSI 'C' for platform independence. Algebraic techniques are used to generate and/or modify block face and volume grids to reflect geometric changes resulting from design optimization. Volume grids are generated/modified in a batch environment and controlled via an ASCII user input deck. This allows the code to be incorporated directly into the design loop. Generated volume grids are presented for a High Speed Civil Transport (HSCT) Wing/Body geometry as well a complex HSCT configuration including horizontal and vertical tails, engine nacelles and pylons, and canard surfaces.
NASA Technical Reports Server (NTRS)
1980-01-01
Twenty-four functional requirements were prepared under six categories and serve to indicate how to integrate dispersed storage generation (DSG) systems with the distribution and other portions of the electric utility system. Results indicate that there are no fundamental technical obstacles to prevent the connection of dispersed storage and generation to the distribution system. However, a communication system of some sophistication is required to integrate the distribution system and the dispersed generation sources for effective control. The large-size span of generators from 10 KW to 30 MW means that a variety of remote monitoring and control may be required. Increased effort is required to develop demonstration equipment to perform the DSG monitoring and control functions and to acquire experience with this equipment in the utility distribution environment.
As-Sanie, Sawsan; Harris, Richard; Napadow, Vitaly; Kim, Jieun; Neshewat, Gina; Kairys, Anson; Williams, David; Clauw, Daniel; Schmidt-Wilcke, Tobias
2012-01-01
Chronic pelvic pain (CPP) is a highly prevalent pain condition, estimated to affect 15-20% of women in the United States. Endometriosis is often associated with CPP, however other factors, such as pre-existing or concomitant changes of the central pain system, might contribute to the development of chronic pain. We applied voxel-based morphometry to determine whether women with CPP with and without endometriosis display changes in brain morphology in regions known to be involved in pain processing.Four subgroups of women participated: 17 with endometriosis and CPP, 15 with endometriosis without CPP, 6 with CPP without endometriosis, as well as 23 healthy controls. All patients with endometriosis and/or CPP were surgically-confirmed. Relative to controls, women with endometriosis-associated CPP displayed decreased gray matter volume in brain regions involved in pain perception including the left thalamus, left cingulategyrus, right putamen, and right insula. Women with CPP without endometriosis also showed decreases in gray matter volume in the left thalamus. Such decreases were not observed in patients with endometriosis that had no CPP. We conclude thatCPP is associated with changes in regional gray matter volume within the central pain system. Although endometriosis may be an important risk factor for the development of CPP, acting as a cyclic source of peripheral nociceptive input, our data support the notion that changes in the central pain system also play an important role in the development of chronic pain, regardless of the presence of endometriosis. PMID:22387096
Witkowski, Maria Carolina; de Moraes, Maria Antonieta P.; Firpo, Cora Maria F.
2013-01-01
OBJECTIVE: To compare two systems of arterial catheters maintenance in postoperative pediatric surgery using intermittent or continuous infusion of heparin solution and to analyze adverse events related to the site of catheter insertion and the volume of infused heparin solution. METHODS: Randomized control trial with 140 patients selected for continuous infusion group (CIG) and intermittent infusion group (IIG). The variables analyzed were: type of heart disease, permanence time and size of the catheter, insertion site, technique used, volume of heparin solution and adverse events. The descriptive variables were analyzed by Student's t-test and the categorical variables, by chi-square test, being significant p<0.05. RESULTS: The median age was 11 (0-22) months, and 77 (55%) were females. No significant differences between studied variables were found, except for the volume used in CIG (12.0±1.2mL/24 hours) when compared to IIG (5.3±3.5mL/24 hours) with p<0.0003. CONCLUSIONS: The continuous infusion system and the intermittent infusion of heparin solution can be used for intra-arterial catheters maintenance in postoperative pediatric surgery, regardless of patient's clinical and demographic characteristics. Adverse events up to the third postoperative day occurred similarly in both groups. However, the intermittent infusion system usage in underweight children should be considered, due to the lower volume of infused heparin solution [ClinicalTrials.gov Identifier: NCT01097031]. PMID:24473958
Machine intelligence and autonomy for aerospace systems
NASA Technical Reports Server (NTRS)
Heer, Ewald (Editor); Lum, Henry (Editor)
1988-01-01
The present volume discusses progress toward intelligent robot systems in aerospace applications, NASA Space Program automation and robotics efforts, the supervisory control of telerobotics in space, machine intelligence and crew/vehicle interfaces, expert-system terms and building tools, and knowledge-acquisition for autonomous systems. Also discussed are methods for validation of knowledge-based systems, a design methodology for knowledge-based management systems, knowledge-based simulation for aerospace systems, knowledge-based diagnosis, planning and scheduling methods in AI, the treatment of uncertainty in AI, vision-sensing techniques in aerospace applications, image-understanding techniques, tactile sensing for robots, distributed sensor integration, and the control of articulated and deformable space structures.
Development of control systems for space shuttle vehicles. Volume 2: Appendixes
NASA Technical Reports Server (NTRS)
Stone, C. R.; Chase, T. W.; Kiziloz, B. M.; Ward, M. D.
1971-01-01
A launch phase random normal wind model is presented for delta wing, two-stage, space shuttle control system studies. Equations, data, and simulations for conventional launch studies are given as well as pitch and lateral equations and data for covariance analyses of the launch phase of MSFC vehicle B. Lateral equations and data for North American 130G and 134D are also included along with a high-altitude abort simulation.
NASA Technical Reports Server (NTRS)
1973-01-01
A study was conducted to determine the configuration and performance of a space tug. Details of the space tug systems are presented to include: (1) propulsion systems, (2) avionics, (3) thermal control, and (4) electric power subsystems. The data generated include engineering drawings, schematics, subsystem operation, and component description. Various options investigated and the rational for the point design selection are analyzed.
Satellite power systems (SPS) concept definition study. Volume 2, part 1: System engineering
NASA Technical Reports Server (NTRS)
Hanley, G. M.
1980-01-01
Top level trade studies are presented, including comparison of solid state and klystron concepts, higher concentration on the solar cells, composite and aluminum structure, and several variations to the reference concept. Detailed trade studies are presented in each of the subsystem areas (solar array, power distribution, structures, thermal control, attitude control and stationkeeping, microwave transmission, and ground receiving station). A description of the selected point design is also presented.
1990-09-14
and can be fused separately. The RTU’s low-power consumption makes them ideally suited for battery and solar powered applications. 3.5 Redundant...dei movimenti e delle sollecitazioni di una nave in mare tempestoso per mezzo del metodo dello spettro di energia e della teoria della
Electromechanical flight control actuator, volume 2
NASA Technical Reports Server (NTRS)
1978-01-01
Schematic diagrams are given for both the four-channel electromechanical actuator and the single-channel power electronics breadboard. Detailed design data is also given on the gears used in the differential gearbox and a copy of the operations manual for the system is included. Performance test results are given for the EMA motor and its current source indicator, the drive control electronics, and the overall system. The power converter waveform test results are also summarized.
Solar power satellite system definition study. Volume 3: Reference system description, phase 1
NASA Technical Reports Server (NTRS)
1979-01-01
An analysis of the solar power satellite system is presented. The satellite solar energy conversion and microwave power transmission systems are discussed including the structure, power distribution, thermal control, and energy storage. Space construction and support systems are described including the work support facilities and construction equipment. An assessment of the space transportation system for the satellite and the ground receiving station is presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... to systems operated by NASDAQ, including the Nasdaq Market Center, the FINRA/NASDAQ Trade Reporting... front-end system for low volume users. NASDAQ proposes to increase the monthly fee assessed for greater... using any facility or system that NASDAQ operates or controls, and it does not unfairly discriminate...
Effect of alcohol exposure on fetal brain development
NASA Astrophysics Data System (ADS)
Sudheendran, Narendran; Bake, Shameena; Miranda, Rajesh C.; Larin, Kirill V.
2013-02-01
Alcohol consumption during pregnancy can be severely damage to the brain development in fetuses. This study investigates the effects of maternal ethanol consumption on brain development in mice embryos. Pregnant mice at gestational day 12.5 were intragastrically gavaged with ethanol (3g/Kg bwt) twice daily for three consecutive days. On gestational day 14.5, fetuses were collected and fixed in 4% paraformaldehyde and imaged using a swept-source optical coherence tomography (SSOCT) system. 3D images of the mice embryo brain were obtained and the volumes of the left and right ventricles of the brain were measured. The average volumes of the left and the right volumes of 5 embryos each alcohol-exposed and control embryos were measured to be 0.35 and 0.15 mm3, respectively. The results suggest that the left and right ventricle volumes of brain are much larger in the alcohol-exposed embryos as compared to control embryos indicating alcohol-induced developmental delay.
Hao, Tian
2017-02-22
The Hall effects, especially the integer, fractional and anomalous quantum Hall effects, have been addressed using Eyring's rate process theory and free volume concept. The basic assumptions are that the conduction process is a common rate controlled "reaction" process that can be described with Eyring's absolute rate process theory; the mobility of electrons should be dependent on the free volume available for conduction electrons. The obtained Hall conductivity is clearly quantized as with prefactors related to both the magnetic flux quantum number and the magnetic quantum number via the azimuthal quantum number, with and without an externally applied magnetic field. This article focuses on two dimensional (2D) systems, but the approaches developed in this article can be extended to 3D systems.
The computational structural mechanics testbed architecture. Volume 2: The interface
NASA Technical Reports Server (NTRS)
Felippa, Carlos A.
1988-01-01
This is the third set of five volumes which describe the software architecture for the Computational Structural Mechanics Testbed. Derived from NICE, an integrated software system developed at Lockheed Palo Alto Research Laboratory, the architecture is composed of the command language CLAMP, the command language interpreter CLIP, and the data manager GAL. Volumes 1, 2, and 3 (NASA CR's 178384, 178385, and 178386, respectively) describe CLAMP and CLIP and the CLIP-processor interface. Volumes 4 and 5 (NASA CR's 178387 and 178388, respectively) describe GAL and its low-level I/O. CLAMP, an acronym for Command Language for Applied Mechanics Processors, is designed to control the flow of execution of processors written for NICE. Volume 3 describes the CLIP-Processor interface and related topics. It is intended only for processor developers.
The computational structural mechanics testbed architecture. Volume 1: The language
NASA Technical Reports Server (NTRS)
Felippa, Carlos A.
1988-01-01
This is the first set of five volumes which describe the software architecture for the Computational Structural Mechanics Testbed. Derived from NICE, an integrated software system developed at Lockheed Palo Alto Research Laboratory, the architecture is composed of the command language CLAMP, the command language interpreter CLIP, and the data manager GAL. Volumes 1, 2, and 3 (NASA CR's 178384, 178385, and 178386, respectively) describe CLAMP and CLIP, and the CLIP-processor interface. Volumes 4 and 5 (NASA CR's 178387 and 178388, respectively) describe GAL and its low-level I/O. CLAMP, an acronym for Command Language for Applied Mechanics Processors, is designed to control the flow of execution of processors written for NICE. Volume 1 presents the basic elements of the CLAMP language and is intended for all users.
The computational structural mechanics testbed architecture. Volume 2: Directives
NASA Technical Reports Server (NTRS)
Felippa, Carlos A.
1989-01-01
This is the second of a set of five volumes which describe the software architecture for the Computational Structural Mechanics Testbed. Derived from NICE, an integrated software system developed at Lockheed Palo Alto Research Laboratory, the architecture is composed of the command language (CLAMP), the command language interpreter (CLIP), and the data manager (GAL). Volumes 1, 2, and 3 (NASA CR's 178384, 178385, and 178386, respectively) describe CLAMP and CLIP and the CLIP-processor interface. Volumes 4 and 5 (NASA CR's 178387 and 178388, respectively) describe GAL and its low-level I/O. CLAMP, an acronym for Command Language for Applied Mechanics Processors, is designed to control the flow of execution of processors written for NICE. Volume 2 describes the CLIP directives in detail. It is intended for intermediate and advanced users.
Monitoring and controlling ATLAS data management: The Rucio web user interface
NASA Astrophysics Data System (ADS)
Lassnig, M.; Beermann, T.; Vigne, R.; Barisits, M.; Garonne, V.; Serfon, C.
2015-12-01
The monitoring and controlling interfaces of the previous data management system DQ2 followed the evolutionary requirements and needs of the ATLAS collaboration. The new data management system, Rucio, has put in place a redesigned web-based interface based upon the lessons learnt from DQ2, and the increased volume of managed information. This interface encompasses both a monitoring and controlling component, and allows easy integration for usergenerated views. The interface follows three design principles. First, the collection and storage of data from internal and external systems is asynchronous to reduce latency. This includes the use of technologies like ActiveMQ or Nagios. Second, analysis of the data into information is done massively parallel due to its volume, using a combined approach with an Oracle database and Hadoop MapReduce. Third, sharing of the information does not distinguish between human or programmatic access, making it easy to access selective parts of the information both in constrained frontends like web-browsers as well as remote services. This contribution will detail the reasons for these principles and the design choices taken. Additionally, the implementation, the interactions with external systems, and an evaluation of the system in production, both from a technological and user perspective, conclude this contribution.
How to Recharge a Confined Aquifer: An Exploration of Geologic Controls on Groundwater Storage.
NASA Astrophysics Data System (ADS)
Maples, S.; Fogg, G. E.; Maxwell, R. M.; Liu, Y.
2017-12-01
Decreased snowpack storage and groundwater overdraft in California has increased interest in managed aquifer recharge (MAR) of excess winter runoff to the Central Valley aquifer system, which has unused storage capacity that far exceeds the state's surface reservoirs. Recharge to the productive, confined aquifer system remains a challenge due to the presence of nearly-ubiquitous, multiple silt and clay confining units that limit recharge pathways. However, previous studies have identified interconnected networks of sand and gravel deposits that bypass the confining units and accommodate rapid, high-volume recharge to the confined aquifer system in select locations. We use the variably-saturated, fully-integrated groundwater/surface-water flow code, ParFlow, in combination with a high-resolution, transition probability Markov-chain geostatistical model of the subsurface geologic heterogeneity of the east side of the Sacramento Valley, CA, to characterize recharge potential across a landscape that includes these geologic features. Multiple 180-day MAR simulations show that recharge potential is highly dependent on subsurface geologic structure, with a several order-of-magnitude range of recharge rates and volumes across the landscape. Where there are recharge pathways to the productive confined-aquifer system, pressure propagation in the confined system is widespread and rapid, with multi-kilometer lateral pressure propagation. Although widespread pressure propagation occurs in the confined system, only a small fraction of recharge volume is accommodated there. Instead, the majority of recharge occurs by filling unsaturated pore spaces. Where they outcrop at land surface, high-K recharge pathways fill rapidly, accommodating the majority of recharge during early time. However, these features become saturated quickly, and somewhat counterintuitively, the low-K silt and clay facies accommodate the majority of recharge volume during most of the simulation. These findings (1) highlight the large variability of MAR potential across the landscape, wherein the recharge capacity in select areas far exceeds recharge potential over most of the landscape, and (2) elucidate important physical processes that control MAR potential in alluvial aquifer systems.
Respiratory muscles stretching acutely increases expansion in hemiparetic chest wall.
Rattes, Catarina; Campos, Shirley Lima; Morais, Caio; Gonçalves, Thiago; Sayão, Larissa Bouwman; Galindo-Filho, Valdecir Castor; Parreira, Verônica; Aliverti, Andrea; Dornelas de Andrade, Armèle
2018-08-01
Individuals post-stroke may present restrictive ventilatory pattern generated from changes in the functionality of respiratory system due to muscle spasticity and contractures. Objective was to assess the acute effects after respiratory muscle stretching on the ventilatory pattern and volume distribution of the chest wall in stroke subjects. Ten volunteers with right hemiparesis after stroke and a mean age of 60 ± 5.7 years were randomised into the following interventions: respiratory muscle stretching and at rest (control). The ventilatory pattern and chest wall volume distribution were evaluated through optoelectronic plethysmography before and immediately after each intervention. Respiratory muscle stretching promoted a significant acute increase of 120 mL in tidal volume, with an increase in minute ventilation, mean inspiratory flow and mean expiratory flow compared with the control group. Pulmonary ribcage increased 50 mL after stretching, with 30 mL of contribution to the right pulmonary rib cage (hemiparetic side) in comparison to the control group. Respiratory muscle stretching in patients with right hemiparesis post-stroke demonstrated that acute effects improve the expansion of the respiratory system during tidal breathing. NCT02416349 (URL: https://clinicaltrials.gov/ct2/show/ NCT02416349). Copyright © 2018 Elsevier B.V. All rights reserved.
Proceedings of the Workshop on Identification and Control of Flexible Space Structures, Volume 2
NASA Technical Reports Server (NTRS)
Rodriguez, G. (Editor)
1985-01-01
The results of a workshop on identification and control of flexible space structures held in San Diego, CA, July 4 to 6, 1984 are discussed. The main objectives of the workshop were to provide a forum to exchange ideas in exploring the most advanced modeling, estimation, identification and control methodologies to flexible space structures. The workshop responded to the rapidly growing interest within NASA in large space systems (space station, platforms, antennas, flight experiments) currently under design. Dynamic structural analysis, control theory, structural vibration and stability, and distributed parameter systems are discussed.
Energy Management System Successful in Indiana Elementary School.
ERIC Educational Resources Information Center
School Business Affairs, 1984
1984-01-01
The new Oregon-Davis Elementary School in rural Indiana embodies state-of-the-art energy management. Its environmental systems include thorough insulation, dual heating and cooling equipment for flexible loads, and decentralized computer controls. A heat recovery unit and variable-air-volume discharge ducts also contribute to conservation. (MCG)
The Renal Renin-Angiotensin System
ERIC Educational Resources Information Center
Harrison-Bernard, Lisa M.
2009-01-01
The renin-angiotensin system (RAS) is a critical regulator of sodium balance, extracellular fluid volume, vascular resistance, and, ultimately, arterial blood pressure. In the kidney, angiotensin II exerts its effects to conserve salt and water through a combination of the hemodynamic control of renal blood flow and glomerular filtration rate and…
Metropolitan School Organization: Basic Problems and Patterns. Volume 1.
ERIC Educational Resources Information Center
McKelvey, Troy V., Ed.
This anthology describes and discusses the study and development of metropolitan educational delivery systems--the process of bringing education under the control of one system spanning the city and its suburbs. Substantive works focus on the forces presently surrounding the problem of metropolitan educational reform and the present state of…
Laser program annual report, 1977. Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bender, C.F.; Jarman, B.D.
1978-07-01
An overview is given of the laser fusion program. The solid-state program covers the Shiva and Nova projects. Laser components, control systems, alignment systems, laser beam diagnostics, power conditioning, and optical components are described. The fusion experimental program concerns the diagnostics and data acquisition associated with Argus and Shiva. (MOW)
NASA Astrophysics Data System (ADS)
Graham, Thomas; Wheeler, Raymond
2016-06-01
The objective of this study was to evaluate root restriction as a tool to increase volume utilization efficiency in spaceflight crop production systems. Bell pepper plants (Capsicum annuum cv. California Wonder) were grown under restricted rooting volume conditions in controlled environment chambers. The rooting volume was restricted to 500 ml and 60 ml in a preliminary trial, and 1500 ml (large), 500 ml (medium), and 250 ml (small) for a full fruiting trial. To reduce the possible confounding effects of water and nutrient restrictions, care was taken to ensure an even and consistent soil moisture throughout the study, with plants being watered/fertilized several times daily with a low concentration soluble fertilizer solution. Root restriction resulted in a general reduction in biomass production, height, leaf area, and transpiration rate; however, the fruit production was not significantly reduced in the root restricted plants under the employed environmental and horticultural conditions. There was a 21% reduction in total height and a 23% reduction in overall crown diameter between the large and small pot size in the fruiting study. Data from the fruiting trial were used to estimate potential volume utilization efficiency improvements for edible biomass in a fixed production volume. For fixed lighting and rooting hardware situations, the majority of improvement from root restriction was in the reduction of canopy area per plant, while height reductions could also improve volume utilization efficiency in high stacked or vertical agricultural systems.
Graham, Thomas; Wheeler, Raymond
2016-06-01
The objective of this study was to evaluate root restriction as a tool to increase volume utilization efficiency in spaceflight crop production systems. Bell pepper plants (Capsicum annuum cv. California Wonder) were grown under restricted rooting volume conditions in controlled environment chambers. The rooting volume was restricted to 500ml and 60ml in a preliminary trial, and 1500ml (large), 500ml (medium), and 250ml (small) for a full fruiting trial. To reduce the possible confounding effects of water and nutrient restrictions, care was taken to ensure an even and consistent soil moisture throughout the study, with plants being watered/fertilized several times daily with a low concentration soluble fertilizer solution. Root restriction resulted in a general reduction in biomass production, height, leaf area, and transpiration rate; however, the fruit production was not significantly reduced in the root restricted plants under the employed environmental and horticultural conditions. There was a 21% reduction in total height and a 23% reduction in overall crown diameter between the large and small pot size in the fruiting study. Data from the fruiting trial were used to estimate potential volume utilization efficiency improvements for edible biomass in a fixed production volume. For fixed lighting and rooting hardware situations, the majority of improvement from root restriction was in the reduction of canopy area per plant, while height reductions could also improve volume utilization efficiency in high stacked or vertical agricultural systems. Copyright © 2016 The Committee on Space Research (COSPAR). All rights reserved.
Rapid Cycling CO2 and H2O Removal System for EMU
NASA Technical Reports Server (NTRS)
Alptekin, Gokhan; Cates, Matthew; Dubovik, Margarita; Gershanovich, Yevgenia; Paul, Heather; Thomas, Gretchen
2006-01-01
NASA's planned future missions set stringent demands on the design of the Portable Life Support Systems (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the EMU is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The CO2 and humidity control unit in the existing PLSS design is relatively large, since it has to remove 8 hours worth of CO2. If the sorbent regeneration can be carried out during the extravehicular activity (EVA) with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced. TDA Research, Inc. (TDA) is developing a compact, regenerable sorbent-based system to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all duration-limiting elements in the life support system. This paper summarizes the results of the sorbent development and testing, and evaluation efforts. The results of a preliminary system analysis are also included, showing the size and volume reductions provided by the new system.
Advanced Three-Dimensional Display System
NASA Technical Reports Server (NTRS)
Geng, Jason
2005-01-01
A desktop-scale, computer-controlled display system, initially developed for NASA and now known as the VolumeViewer(TradeMark), generates three-dimensional (3D) images of 3D objects in a display volume. This system differs fundamentally from stereoscopic and holographic display systems: The images generated by this system are truly 3D in that they can be viewed from almost any angle, without the aid of special eyeglasses. It is possible to walk around the system while gazing at its display volume to see a displayed object from a changing perspective, and multiple observers standing at different positions around the display can view the object simultaneously from their individual perspectives, as though the displayed object were a real 3D object. At the time of writing this article, only partial information on the design and principle of operation of the system was available. It is known that the system includes a high-speed, silicon-backplane, ferroelectric-liquid-crystal spatial light modulator (SLM), multiple high-power lasers for projecting images in multiple colors, a rotating helix that serves as a moving screen for displaying voxels [volume cells or volume elements, in analogy to pixels (picture cells or picture elements) in two-dimensional (2D) images], and a host computer. The rotating helix and its motor drive are the only moving parts. Under control by the host computer, a stream of 2D image patterns is generated on the SLM and projected through optics onto the surface of the rotating helix. The system utilizes a parallel pixel/voxel-addressing scheme: All the pixels of the 2D pattern on the SLM are addressed simultaneously by laser beams. This parallel addressing scheme overcomes the difficulty of achieving both high resolution and a high frame rate in a raster scanning or serial addressing scheme. It has been reported that the structure of the system is simple and easy to build, that the optical design and alignment are not difficult, and that the system can be built by use of commercial off-the-shelf products. A prototype of the system displays an image of 1,024 by 768 by 170 (=133,693,440) voxels. In future designs, the resolution could be increased. The maximum number of voxels that can be generated depends upon the spatial resolution of SLM and the speed of rotation of the helix. For example, one could use an available SLM that has 1,024 by 1,024 pixels. Incidentally, this SLM is capable of operation at a switching speed of 300,000 frames per second. Implementation of full-color displays in future versions of the system would be straightforward: One could use three SLMs for red, green, and blue, respectively, and the colors of the voxels could be automatically controlled. An optically simpler alternative would be to use a single red/green/ blue light projector and synchronize the projection of each color with the generation of patterns for that color on a single SLM.
Tang, X; Liu, H; Chen, L; Wang, Q; Luo, B; Xiang, N; He, Y; Zhu, W; Zhang, J
2018-05-24
To investigate the accuracy of two semi-automatic segmentation measurements based on magnetic resonance imaging (MRI) three-dimensional (3D) Cube fast spin echo (FSE)-flex sequence in phantoms, and to evaluate the feasibility of determining the volumetric alterations of orbital fat (OF) and total extraocular muscles (TEM) in patients with thyroid-associated ophthalmopathy (TAO) by semi-automatic segmentation. Forty-four fatty (n=22) and lean (n=22) phantoms were scanned by using Cube FSE-flex sequence with a 3 T MRI system. Their volumes were measured by manual segmentation (MS) and two semi-automatic segmentation algorithms (regional growing [RG], multi-dimensional threshold [MDT]). Pearson correlation and Bland-Altman analysis were used to evaluate the measuring accuracy of MS, RG, and MDT in phantoms as compared with the true volume. Then, OF and TEM volumes of 15 TAO patients and 15 normal controls were measured using MDT. Paired-sample t-tests were used to compare the volumes and volume ratios of different orbital tissues between TAO patients and controls. Each segmentation (MS RG, MDT) has a significant correlation (p<0.01) with true volume. There was a minimal bias for MS, and a stronger agreement between MDT and the true volume than RG and the true volume both in fatty and lean phantoms. The reproducibility of Cube FSE-flex determined MDT was adequate. The volumetric ratios of OF/globe (p<0.01), TEM/globe (p<0.01), whole orbit/globe (p<0.01) and bone orbit/globe (p<0.01) were significantly greater in TAO patients than those in healthy controls. MRI Cube FSE-flex determined MDT is a relatively accurate semi-automatic segmentation that can be used to evaluate OF and TEM volumes in clinic. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Laforge, François O; Carpino, James; Rotenberg, Susan A; Mirkin, Michael V
2007-07-17
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10(-18) to 10(-12) liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.
Laforge, François O.; Carpino, James; Rotenberg, Susan A.; Mirkin, Michael V.
2007-01-01
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10−18 to 10−12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems. PMID:17620612
The in vivo wear resistance of 12 composite resins.
Lang, B R; Bloem, T J; Powers, J M; Wang, R F
1992-09-01
The in vivo wear resistance of 12 composite resins were compared with an amalgam control using the Latin Square experimental design. Sixteen edentulous patients wearing specially designed complete dentures formed the experimental population. The Michigan Computer Graphics Measurement System was used to digitize the surface of the control and composite resin samples before and after 3-month test periods to obtain wear data. The 12 composite resins selected for this investigation based on their published composite classification types were seven fine particle composites, three blends, and two microfilled composite resins. The Latin Square experimental design was found to be valid with the factor of material being statistically different at the 5% level of significance. Wear was computed as volume loss (mm3/mm2), and all of the composites studied had more wear than the amalgam control (P = .001). After 3 months, the mean (error) of wear of the amalgam was 0.028 (0.006). Means (error) of wear for the 12 composites were ranked from most to least wear by mean wear volume loss. The absence of any relationship between mean wear volume loss and the volume percentage filler was confirmed by the correlation coefficient r = -0.158.
Froum, Stuart J; Wallace, Stephen; Cho, Sang-Choon; Khouly, Ismael; Rosenberg, Edwin; Corby, Patricia; Froum, Scott; Mascarenhas, Patrick; Tarnow, Dennis P
2014-01-01
The purpose of this study was to radiographically evaluate, then analyze, bone height, volume, and density with reference to percentage of vital bone after maxillary sinuses were grafted using two different doses of recombinant human bone morphogenetic protein 2/acellular collagen sponge (rhBMP-2/ACS) combined with mineralized cancellous bone allograft (MCBA) and a control sinus grafted with MCBA only. A total of 18 patients (36 sinuses) were used for analysis of height and volume measurements, having two of three graft combinations (one in each sinus): (1) control, MCBA only; (2) test 1, MCBA + 5.6 mL of rhBMP-2/ACS (containing 8.4 mg of rhBMP-2); and (3) test 2, MCBA + 2.8 mL of rhBMP-2/ACS (containing 4.2 mg of rhBMP-2). The study was completed with 16 patients who also had bilateral cores removed 6 to 9 months following sinus augmentation. A computer software system was used to evaluate 36 computed tomography scans. Two time points where selected for measurements of height: The results indicated that height of the grafted sinus was significantly greater in the treatment groups compared with the control. However, by the second time point, there were no statistically significant differences. Three weeks post-surgery bone volume measurements showed similar statistically significant differences between test and controls. However, prior to core removal, test group 1 with the greater dose of rhBMP-2 showed a statistically significant greater increase compared with test group 2 and the control. There was no statistically significant difference between the latter two groups. All three groups had similar volume and shrinkage. Density measurements varied from the above results, with the control showing statistically significant greater density at both time points. By contrast, the density increase over time in both rhBMP groups was similar and statistically higher than in the control group. There were strong associations between height and volume in all groups and between volume and new vital bone only in the control group. There were no statistically significant relationships observed between height and bone density or between volume and bone density for any parameter measured. More cases and monitoring of the future survival of implants placed in these augmented sinuses are needed to verify these results.
NASA Tech Briefs, June 2002. Volume 26, No. 6
NASA Technical Reports Server (NTRS)
2002-01-01
Topics include: a technology focus on data acquisition, electronic components and systems, software, materials, mechanics, machinery/automation, physical sciences, book and reports, motion control, and a special section of Photonics Tech Briefs.
Small Aircraft Transportation System, Higher Volume Operations Concept: Off-Nominal Operations
NASA Technical Reports Server (NTRS)
Abbott, Terence S.; Consiglio, Maria C.; Baxley, Brian T.; Williams, Daniel M.; Conway, Sheila R.
2005-01-01
This document expands the Small Aircraft Transportation System, (SATS) Higher Volume Operations (HVO) concept to include off-nominal conditions. The general philosophy underlying the HVO concept is the establishment of a newly defined area of flight operations called a Self-Controlled Area (SCA). During periods of poor weather, a block of airspace would be established around designated non-towered, non-radar airports. Aircraft flying enroute to a SATS airport would be on a standard instrument flight rules flight clearance with Air Traffic Control providing separation services. Within the SCA, pilots would take responsibility for separation assurance between their aircraft and other similarly equipped aircraft. Previous work developed the procedures for normal HVO operations. This document provides details for off-nominal and emergency procedures for situations that could be expected to occur in a future SCA.
Water-vapor pressure control in a volume
NASA Technical Reports Server (NTRS)
Scialdone, J. J.
1978-01-01
The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.
Within-band spray distribution of nozzles used for herbaceous plant control
James H. Miller
1994-01-01
Abstract. Described are the spray patterns of nozzles setup for banded herbaceous plant control treatments. Spraying Systems Company nozzles. were tested, but similar nozzles are available from other manufacturers. Desirable traits were considered to be as follows: an even distribution pattern, low volume, low height, large droplets, and a single...
1990-04-01
SURVEILLANCE & WARNING SYTEMS A2C COMMAND & CONTROL ACTIVITIES A2D SPACE ACTIVITIES (STRATEGIC CONTROL & SURV) A2E STRAT CONTROL & SURV: COMMUNICATIONS A2F...STRATEGIC AIR DEFENSE 0501802A NIKE-AJAX (ARNS) (H) AID STRATEGIC AIR DEFENSE AIC SPACE DEFENSE OI02115N F-6 Squadrons (H) AIC SPACE DEFENSE 0102215N ABM ...WARNING SYTEMS 0102310F NCHC - TW/AA Systems A2B SURVEILLANCE & WARNIIIG SYTEMS 0102311F NCMC - Space Defense Systems A21 SURVEILLANCE & WARNING SYTEMS
1993-07-09
real-time simulation capabilities, highly non -linear control devices, work space path planing, active control of machine flexibilities and reliability...P.M., "The Information Capacity of the Human Motor System in Controlling the Amplitude of Movement," Journal of Experimental Psychology, Vol 47, No...driven many research groups in the challenging problem of flexible sy,;tems with an increasing interaction with finite element methodologies. Basic
NASA Technical Reports Server (NTRS)
Alexander, H. R.; Smith, K. E.; Mcveigh, M. A.; Dixon, P. G.; Mcmanus, B. L.
1979-01-01
Composite structures technology is applied in a preliminary design study of advanced technology blades and hubs for the XV-15 tilt rotor research demonstrator aircraft. Significant improvements in XV-15 hover and cruise performance are available using blades designed for compatibility with the existing aircraft, i.e., blade installation would not require modification of the airframe, hub or upper controls. Provision of a low risk nonmechanical control system was also studied, and a development specification is given.
Cerebrospinal fluid volume measurements in hydrocephalic rats.
Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas
2012-10-01
Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic (long-term) volume monitoring system.
Navigation Performance of Global Navigation Satellite Systems in the Space Service Volume
NASA Technical Reports Server (NTRS)
Force, Dale A.
2013-01-01
This paper extends the results I reported at this year's ION International Technical Meeting on multi-constellation GNSS coverage by showing how the use of multi-constellation GNSS improves Geometric Dilution of Precision (GDOP). Originally developed to provide position, navigation, and timing for terrestrial users, GPS has found increasing use for in space for precision orbit determination, precise time synchronization, real-time spacecraft navigation, and three-axis attitude control of Earth orbiting satellites. With additional Global Navigation Satellite Systems (GNSS) coming into service (GLONASS, Galileo, and Beidou) and the development of Satellite Based Augmentation Services, it is possible to obtain improved precision by using evolving multi-constellation receiver. The Space Service Volume formally defined as the volume of space between three thousand kilometers altitude and geosynchronous altitude ((is) approximately 36,500 km), with the volume below three thousand kilometers defined as the Terrestrial Service Volume (TSV). The USA has established signal requirements for the Space Service Volume (SSV) as part of the GPS Capability Development Documentation (CDD). Diplomatic efforts are underway to extend Space service Volume commitments to the other Position, Navigation, and Timing (PNT) service providers in an effort to assure that all space users will benefit from the enhanced capabilities of interoperating GNSS services in the space domain.
NASA Technical Reports Server (NTRS)
Dreisbach, R. L. (Editor)
1979-01-01
The input data and execution control statements for the ATLAS integrated structural analysis and design system are described. It is operational on the Control Data Corporation (CDC) 6600/CYBER computers in a batch mode or in a time-shared mode via interactive graphic or text terminals. ATLAS is a modular system of computer codes with common executive and data base management components. The system provides an extensive set of general-purpose technical programs with analytical capabilities including stiffness, stress, loads, mass, substructuring, strength design, unsteady aerodynamics, vibration, and flutter analyses. The sequence and mode of execution of selected program modules are controlled via a common user-oriented language.
Optically controlled phased-array antenna technology for space communication systems
NASA Technical Reports Server (NTRS)
Kunath, Richard R.; Bhasin, Kul B.
1988-01-01
Using MMICs in phased-array applications above 20 GHz requires complex RF and control signal distribution systems. Conventional waveguide, coaxial cable, and microstrip methods are undesirable due to their high weight, high loss, limited mechanical flexibility and large volume. An attractive alternative to these transmission media, for RF and control signal distribution in MMIC phased-array antennas, is optical fiber. Presented are potential system architectures and their associated characteristics. The status of high frequency opto-electronic components needed to realize the potential system architectures is also discussed. It is concluded that an optical fiber network will reduce weight and complexity, and increase reliability and performance, but may require higher power.
Space station automation of common module power management and distribution, volume 2
NASA Technical Reports Server (NTRS)
Ashworth, B.; Riedesel, J.; Myers, C.; Jakstas, L.; Smith, D.
1990-01-01
The new Space Station Module Power Management and Distribution System (SSM/PMAD) testbed automation system is described. The subjects discussed include testbed 120 volt dc star bus configuration and operation, SSM/PMAD automation system architecture, fault recovery and management expert system (FRAMES) rules english representation, the SSM/PMAD user interface, and the SSM/PMAD future direction. Several appendices are presented and include the following: SSM/PMAD interface user manual version 1.0, SSM/PMAD lowest level processor (LLP) reference, SSM/PMAD technical reference version 1.0, SSM/PMAD LLP visual control logic representation's (VCLR's), SSM/PMAD LLP/FRAMES interface control document (ICD) , and SSM/PMAD LLP switchgear interface controller (SIC) ICD.