Substantiation of Structure of Adaptive Control Systems for Motor Units
NASA Astrophysics Data System (ADS)
Ovsyannikov, S. I.
2018-05-01
The article describes the development of new electronic control systems, in particular motor units, for small-sized agricultural equipment. Based on the analysis of traffic control systems, the main course of development of the conceptual designs of motor units has been defined. The systems aimed to control the course motion of the motor unit in automatic mode using the adaptive systems have been developed. The article presents structural models of the conceptual motor units based on electrically controlled systems by the operation of drive motors and adaptive systems that make the motor units completely automated.
Wireless power charging using point of load controlled high frequency power converters
Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.
2015-10-13
An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.
Personal customizing exercise with a wearable measurement and control unit.
Wang, Zhihui; Kiryu, Tohru; Tamura, Naoki
2005-06-28
Recently, wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of customizing machine-based exercise on an individual basis by relying on biosignal-based controls. We propose a new wearable unit design equipped with measurement and control functions to support the customization process. The wearable unit can measure the heart rate and electromyogram signals during exercise performance and output workload control commands to the exercise machines. The workload is continuously tracked with exercise programs set according to personally customized workload patterns and estimation results from the measured biosignals by a fuzzy control method. Exercise programs are adapted by relying on a computer workstation, which communicates with the wearable unit via wireless connections. A prototype of the wearable unit was tested together with an Internet-based cycle ergometer system to demonstrate that it is possible to customize exercise on an individual basis. We tested the wearable unit in nine people to assess its suitability to control cycle ergometer exercise. The results confirmed that the unit could successfully control the ergometer workload and continuously support gradual changes in physical activities. The design of wearable units equipped with measurement and control functions is an important step towards establishing a convenient and continuously supported wellness environment.
A miniaturized digital telemetry system for physiological data transmission
NASA Technical Reports Server (NTRS)
Portnoy, W. M.; Stotts, L. J.
1978-01-01
A physiological date telemetry system, consisting basically of a portable unit and a ground base station was designed, built, and tested. The portable unit to be worn by the subject is composed of a single crystal controlled transmitter with AM transmission of digital data and narrowband FM transmission of voice; a crystal controlled FM receiver; thirteen input channels follwed by a PCM encoder (three of these channels are designed for ECG data); a calibration unit; and a transponder control system. The ground base station consists of a standard telemetry reciever, a decoder, and an FM transmitter for transmission of voice and transponder signals to the portable unit. The ground base station has complete control of power to all subsystems in the portable unit. The phase-locked loop circuit which is used to decode the data, remains in operation even when the signal from the portable unit is interrupted.
Personal customizing exercise with a wearable measurement and control unit
Wang, Zhihui; Kiryu, Tohru; Tamura, Naoki
2005-01-01
Background Recently, wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of customizing machine-based exercise on an individual basis by relying on biosignal-based controls. We propose a new wearable unit design equipped with measurement and control functions to support the customization process. Methods The wearable unit can measure the heart rate and electromyogram signals during exercise performance and output workload control commands to the exercise machines. The workload is continuously tracked with exercise programs set according to personally customized workload patterns and estimation results from the measured biosignals by a fuzzy control method. Exercise programs are adapted by relying on a computer workstation, which communicates with the wearable unit via wireless connections. A prototype of the wearable unit was tested together with an Internet-based cycle ergometer system to demonstrate that it is possible to customize exercise on an individual basis. Results We tested the wearable unit in nine people to assess its suitability to control cycle ergometer exercise. The results confirmed that the unit could successfully control the ergometer workload and continuously support gradual changes in physical activities. Conclusion The design of wearable units equipped with measurement and control functions is an important step towards establishing a convenient and continuously supported wellness environment. PMID:15982425
Wang, Zhihui; Tamura, Naoki; Kiryu, Tohru
2005-01-01
Wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of personal customizing machine-supported exercise that have biosignal-based controls. In this paper, we propose a new wearable unit design equipped with measurement and control functions to support the personal customization process. The wearable unit can measure the heart rate and electromyogram signals during exercise and output workload control commands to the exercise machines. We then applied a prototype of the wearable unit to an Internet-based cycle ergometer system. The wearable unit was examined using twelve young people to check its feasibility. The results verified that the unit could successfully adapt to the control of the workload and was effective for continuously supporting gradual changes in physical activities.
Drive Control System for Pipeline Crawl Robot Based on CAN Bus
NASA Astrophysics Data System (ADS)
Chen, H. J.; Gao, B. T.; Zhang, X. H.; Deng2, Z. Q.
2006-10-01
Drive control system plays important roles in pipeline robot. In order to inspect the flaw and corrosion of seabed crude oil pipeline, an original mobile pipeline robot with crawler drive unit, power and monitor unit, central control unit, and ultrasonic wave inspection device is developed. The CAN bus connects these different function units and presents a reliable information channel. Considering the limited space, a compact hardware system is designed based on an ARM processor with two CAN controllers. With made-to-order CAN protocol for the crawl robot, an intelligent drive control system is developed. The implementation of the crawl robot demonstrates that the presented drive control scheme can meet the motion control requirements of the underwater pipeline crawl robot.
Multichannel optical sensing device
Selkowitz, S.E.
1985-08-16
A multichannel optical sensing device is disclosed, for measuring the outdoor sky luminance or illuminance or the luminance or illuminance distribution in a room, comprising a plurality of light receptors, an optical shutter matrix including a plurality of liquid crystal optical shutter elements operable by electrical control signals between light transmitting and light stopping conditions, fiber optical elements connected between the receptors and the shutter elements, a microprocessor based programmable control unit for selectively supplying control signals to the optical shutter elements in a programmable sequence, a photodetector including an optical integrating spherical chamber having an input port for receiving the light from the shutter matrix and at least one detector element in the spherical chamber for producing output signals corresponding to the light, and output units for utilizing the output signals including a storage unit having a control connection to the microprocessor based programmable control unit for storing the output signals under the sequence control of the programmable control unit.
Multichannel optical sensing device
Selkowitz, Stephen E.
1990-01-01
A multichannel optical sensing device is disclosed, for measuring the outr sky luminance or illuminance or the luminance or illuminance distribution in a room, comprising a plurality of light receptors, an optical shutter matrix including a plurality of liquid crystal optical shutter elements operable by electrical control signals between light transmitting and light stopping conditions, fiber optic elements connected between the receptors and the shutter elements, a microprocessor based programmable control unit for selectively supplying control signals to the optical shutter elements in a programmable sequence, a photodetector including an optical integrating spherical chamber having an input port for receiving the light from the shutter matrix and at least one detector element in the spherical chamber for producing output signals corresponding to the light, and output units for utilizing the output signals including a storage unit having a control connection to the microprocessor based programmable control unit for storing the output signals under the sequence control of the programmable control unit.
An investigation of collisions between fiber positioning units in LAMOST
NASA Astrophysics Data System (ADS)
Liu, Xiao-Jie; Wang, Gang
2016-04-01
The arrangement of fiber positioning units in the LAMOST focal plane may lead to collisions during the fiber allocation process. To avoid these collisions, a software-based protection system has to abandon some targets located in the overlapping field of adjacent fiber units. In this paper, we first analyze the probability of collisions between fibers and infer their possible reasons. It is useful to solve the problem of collisions among fiber positioning units so as to improve the efficiency of LAMOST. Based on this, a collision handling system is designed by using a master-slave control structure between the micro control unit and microcomputer. Simulated experiments validate that the system can provide real-time inspection and swap information between the fiber unit controllers and the main controller.
Interface For Fault-Tolerant Control System
NASA Technical Reports Server (NTRS)
Shaver, Charles; Williamson, Michael
1989-01-01
Interface unit and controller emulator developed for research on electronic helicopter-flight-control systems equipped with artificial intelligence. Interface unit interrupt-driven system designed to link microprocessor-based, quadruply-redundant, asynchronous, ultra-reliable, fault-tolerant control system (controller) with electronic servocontrol unit that controls set of hydraulic actuators. Receives digital feedforward messages from, and transmits digital feedback messages to, controller through differential signal lines or fiber-optic cables (thus far only differential signal lines have been used). Analog signals transmitted to and from servocontrol unit via coaxial cables.
Linear control of a boiler-turbine unit: analysis and design.
Tan, Wen; Fang, Fang; Tian, Liang; Fu, Caifen; Liu, Jizhen
2008-04-01
Linear control of a boiler-turbine unit is discussed in this paper. Based on the nonlinear model of the unit, this paper analyzes the nonlinearity of the unit, and selects the appropriate operating points so that the linear controller can achieve wide-range performance. Simulation and experimental results at the No. 4 Unit at the Dalate Power Plant show that the linear controller can achieve the desired performance under a specific range of load variations.
Real-time performance assessment and adaptive control for a water chiller unit in an HVAC system
NASA Astrophysics Data System (ADS)
Bai, Jianbo; Li, Yang; Chen, Jianhao
2018-02-01
The paper proposes an adaptive control method for a water chiller unit in a HVAC system. Based on the minimum variance evaluation, the adaptive control method was used to realize better control of the water chiller unit. To verify the performance of the adaptive control method, the proposed method was compared with an a conventional PID controller, the simulation results showed that adaptive control method had superior control performance to that of the conventional PID controller.
NASA Technical Reports Server (NTRS)
Delaat, J. C.; Soeder, J. F.
1983-01-01
High speed minicomputers were used in the past to implement advanced digital control algorithms for turbine engines. These minicomputers are typically large and expensive. It is desirable for a number of reasons to use microprocessor-based systems for future controls research. They are relatively compact, inexpensive, and are representative of the hardware that would be used for actual engine-mounted controls. The Control, Interface, and Monitoring Unit (CIM) contains a microprocessor-based controls computer, necessary interface hardware and a system to monitor while it is running an engine. It is presently being used to evaluate an advanced turbofan engine control algorithm.
Model of Rescue Units Control in Event of Potential Emergency
NASA Astrophysics Data System (ADS)
Kalach, A. V.; Kravchenko, A. S.; Soloviev, A. S.; Nesterov, A. A.
2018-05-01
A problem of organization and efficiency improvement of the system controlling the rescue units of the Ministry of Civil Defense and Emergency Response of the Russian Federation considered using the example of potential hydrological emergency, a model of a system for controlling rescue units in the event of potential hydrological emergency. The problem solution is based on mathematical models of operational control of rescue units and assessment of a hydrological situation of area flooding.
Antenna unit and radio base station therewith
Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru
2007-04-10
Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.
Experience with ethylene plant computer control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nasi, M.; Darby, M.L.; Sourander, M.
This article discusses the control strategies, results and opinions of management and operations of a computer based ethylene plant control system. The ethylene unit contains 9 cracking heaters, and its nameplate capacity is 200,000 tpa ethylene. Reports on control performance during different unit loading and using different feedstock types. By converting the yield and utility consumption benefits due to computer control into monetary units, the payback time of the system is less than 2 yrs.
Roadside-based communication system and method
NASA Technical Reports Server (NTRS)
Bachelder, Aaron D. (Inventor)
2007-01-01
A roadside-based communication system providing backup communication between emergency mobile units and emergency command centers. In the event of failure of a primary communication, the mobile units transmit wireless messages to nearby roadside controllers that may take the form of intersection controllers. The intersection controllers receive the wireless messages, convert the messages into standard digital streams, and transmit the digital streams along a citywide network to a destination intersection or command center.
Tuning of PID controllers for boiler-turbine units.
Tan, Wen; Liu, Jizhen; Fang, Fang; Chen, Yanqiao
2004-10-01
A simple two-by-two model for a boiler-turbine unit is demonstrated in this paper. The model can capture the essential dynamics of a unit. The design of a coordinated controller is discussed based on this model. A PID control structure is derived, and a tuning procedure is proposed. The examples show that the method is easy to apply and can achieve acceptable performance.
142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN ...
142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN IN SOUTHWEST PORTION OF CONTROL ROOM (214), LSB (BLDG. 751), FACING WEST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Breen, P P; O'Keeffe, D T; Conway, R; Lyons, G M
2006-03-01
We describe the design of an intelligent drop foot stimulator unit for use in conjunction with a commercial neuromuscular electrical nerve stimulation (NMES) unit, the NT2000. The developed micro-controller unit interfaces to a personal computer (PC) and a graphical user interface (GUI) allows the clinician to graphically specify the shape of the stimulation intensity envelope required for a subject undergoing drop foot correction. The developed unit is based on the ADuC812S micro-controller evaluation board from Analog Devices and uses two force sensitive resistor (FSR) based foot-switches to control application of stimulus. The unit has the ability to display to the clinician how the stimulus intensity envelope is being delivered during walking using a data capture capability. The developed system has a built-in algorithm to dynamically adjust the delivery of stimulus to reflect changes both within the gait cycle and from cycle to cycle. Thus, adaptive control of stimulus intensity is achieved.
Adaptive control system having hedge unit and related apparatus and methods
NASA Technical Reports Server (NTRS)
Johnson, Eric Norman (Inventor); Calise, Anthony J. (Inventor)
2003-01-01
The invention includes an adaptive control system used to control a plant. The adaptive control system includes a hedge unit that receives at least one control signal and a plant state signal. The hedge unit generates a hedge signal based on the control signal, the plant state signal, and a hedge model including a first model having one or more characteristics to which the adaptive control system is not to adapt, and a second model not having the characteristic(s) to which the adaptive control system is not to adapt. The hedge signal is used in the adaptive control system to remove the effect of the characteristic from a signal supplied to an adaptation law unit of the adaptive control system so that the adaptive control system does not adapt to the characteristic in controlling the plant.
HEMP (high-altitude electromagnetic pulse) test and analysis of selected recloser-control units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, T.K.; Sands, S.H.; Tesche, F.M.
A simulated HEMP test was performed on power line recloser-control units in the ARES facility during the month of October 1988. Two types of recloser-control units were tested: an electronic control unit presently in wide use in electric power distribution systems and a new microprocessor based unit presently being introduced to electric utilities. It was found that the ARES fields did not cause reproducible disruptive failure of the equipment. Minor upsets, which were considered to be non-disruptive to the recloser operation, were observed. The test results were compared to the results of an analysis from a previous study and itmore » is concluded that the probability of disruptive failure of field operating recloser-control units subjected to a nominal unclassified HEMP environment is small. 3 refs., 30 figs., 1 tab.« less
MAS2-8 radar and digital control unit
NASA Technical Reports Server (NTRS)
Oberg, J. M.; Ulaby, F. T.
1974-01-01
The design of the MAS 2-8 (2 to 8 GHz microwave-active spectrometer), a ground-based sensor system, is presented. A major modification in 1974 to the MAS 2-8, that of a control subsystem to automate the data-taking operation, is the prime focus. The digital control unit automatically changes all system parameters except FM rate and records the return signal on paper tape. The overall system operation and a detailed discussion of the design and operation of the digital control unit are presented.
56. VIEW OF LAUNCHER FROM SOUTHWEST. NITROGEN CONTROL UNIT ON ...
56. VIEW OF LAUNCHER FROM SOUTHWEST. NITROGEN CONTROL UNIT ON RIGHT; UMBILICAL MAST ON LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
40 CFR 76.10 - Alternative emission limitations.
Code of Federal Regulations, 2013 CFR
2013-07-01
...; and (ii) The installed NOX emission control system has been designed to meet the applicable emission... that the unit and NOX emission control system were operated in accordance with the bid and design specifications on which the design of the NOX emission control system was based; and (C) Unit operating data as...
40 CFR 76.10 - Alternative emission limitations.
Code of Federal Regulations, 2010 CFR
2010-07-01
...; and (ii) The installed NOX emission control system has been designed to meet the applicable emission... that the unit and NOX emission control system were operated in accordance with the bid and design specifications on which the design of the NOX emission control system was based; and (C) Unit operating data as...
NASA Technical Reports Server (NTRS)
Stewart, E. C.; Cannaday, R. L.
1973-01-01
A comparison of the results from a fixed-base, six-degree-of -freedom simulator and a moving-base, three-degree-of-freedom simulator was made for a close-in, EVA-type maneuvering task in which visual cues of a target spacecraft were used for guidance. The maneuvering unit (the foot-controlled maneuvering unit of Skylab Experiment T020) employed an on-off acceleration command control system operated entirely by the feet. Maneuvers by two test subjects were made for the fixed-base simulator in six and three degrees of freedom and for the moving-base simulator in uncontrolled and controlled, EVA-type visual cue conditions. Comparisons of pilot ratings and 13 different quantitative parameters from the two simulators are made. Different results were obtained from the two simulators, and the effects of limited degrees of freedom and uncontrolled visual cues are discussed.
Transmission control unit drive based on the AUTOSAR standard
NASA Astrophysics Data System (ADS)
Guo, Xiucai; Qin, Zhen
2018-03-01
It is a trend of automotive electronics industry in the future that automotive electronics embedded system development based on the AUTOSAR standard. AUTOSAR automotive architecture standard has proposed the transmission control unit (TCU) development architecture and designed its interfaces and configurations in detail. This essay has discussed that how to drive the TCU based on AUTOSAR standard architecture. The results show that driving the TCU with the AUTOSAR system improves reliability and shortens development cycles.
NASA Technical Reports Server (NTRS)
Baez, A. N.
1985-01-01
Research programs have demonstrated that digital electronic controls are more suitable for advanced aircraft/rotorcraft turbine engine systems than hydromechanical controls. Commercially available microprocessors are believed to have the speed and computational capability required for implementing advanced digital control algorithms. Thus, it is desirable to demonstrate that off-the-shelf microprocessors are indeed capable of performing real time control of advanced gas turbine engines. The engine monitoring and control (EMAC) unit was designed and fabricated specifically to meet the requirements of an advanced gas turbine engine control system. The EMAC unit is fully operational in the Army/NASA small turboshaft engine digital research program.
A Short Guide to U.S. Arms Control Policy.
ERIC Educational Resources Information Center
Howard, Norman, Ed.; Sussman, Colleen, Ed.
Steps the United States is taking to lessen the danger of war while building international confidence and security are described. The commitment of the United States to arms control is based on the conviction that the United States and the Soviet Union have a common interest in the avoidance of nuclear war and the survival of the human race. A…
NASA Astrophysics Data System (ADS)
Howlader, Harun Or Rashid; Matayoshi, Hidehito; Noorzad, Ahmad Samim; Muarapaz, Cirio Celestino; Senjyu, Tomonobu
2018-05-01
This paper presents a smart house-based power system for thermal unit commitment programme. The proposed power system consists of smart houses, renewable energy plants and conventional thermal units. The transmission constraints are considered for the proposed system. The generated power of the large capacity renewable energy plant leads to the violated transmission constraints in the thermal unit commitment programme, therefore, the transmission constraint should be considered. This paper focuses on the optimal operation of the thermal units incorporated with controllable loads such as Electrical Vehicle and Heat Pump water heater of the smart houses. The proposed method is compared with the power flow in thermal units operation without controllable loads and the optimal operation without the transmission constraints. Simulation results show the validation of the proposed method.
Dynamically limiting energy consumed by cooling apparatus
Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.
2015-05-26
Cooling apparatuses and methods are provided which include one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is coupled to the N controllable components, and dynamically adjusts operation of the N controllable components, based on Z input parameters and one or more specified constraints, to provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.
Preventing patient-to-worker violence in hospitals: outcome of a randomized controlled intervention
Arnetz, Judith E.; Hamblin, Lydia; Russell, Jim; Upfal, Mark J.; Luborsky, Mark; Janisse, James; Essenmacher, Lynnette
2016-01-01
Objective To evaluate the effects of a randomized controlled intervention on the incidence of patient-to-worker (Type II) violence and related injury in hospitals. Methods Forty-one units across 7 hospitals were randomized into intervention (n=21) and control (n=20) groups. Intervention units received unit-level violence data to facilitate development of an action plan for violence prevention; no data were presented to control units. Main outcomes were rates of violent events and injuries across study groups over time. Results Six months post-intervention, incident rate ratios of violent events were significantly lower on intervention units compared to controls (IRR 0.48, 95% CI 0.29-0.80). At 24 months, the risk for violence-related injury was lower on intervention units, compared to controls (IRR 0.37, 95% CI 0.17-0.83). Conclusion This data-driven, worksite-based intervention was effective in decreasing risks of patient-to-worker violence and related injury. PMID:28045793
47 CFR 90.305 - Location of stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... stations. (a) The transmitter site(s) for base station(s), including mobile relay stations, shall be.... (b) Mobile units shall be operated within 48 km. (30 mi.) of their associated base station or...). (c) Control stations must be located within the area of operation of the mobile units. (d) Base and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
REN, GANG; LIU, JINXIN; LI, HONGCHANG
A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the resultsmore » to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.« less
Jordan, A; Chen, D; Yi, Q-L; Kanias, T; Gladwin, M T; Acker, J P
2016-07-01
Quality control (QC) data collected by blood services are used to monitor production and to ensure compliance with regulatory standards. We demonstrate how analysis of quality control data can be used to highlight the sources of variability within red cell concentrates (RCCs). We merged Canadian Blood Services QC data with manufacturing and donor records for 28 227 RCC between June 2011 and October 2014. Units were categorized based on processing method, bag manufacturer, donor age and donor sex, then assessed based on product characteristics: haemolysis and haemoglobin levels, unit volume, leucocyte count and haematocrit. Buffy-coat method (top/bottom)-processed units exhibited lower haemolysis than units processed using the whole-blood filtration method (top/top). Units from female donors exhibited lower haemolysis than male donations. Processing method influenced unit volume and the ratio of additive solution to residual plasma. Stored red blood cell characteristics are influenced by prestorage processing and donor factors. Understanding the relationship between processing, donors and RCC quality will help blood services to ensure the safety of transfused products. © 2016 International Society of Blood Transfusion.
Dynamically limiting energy consumed by cooling apparatus
Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.
2015-06-09
Cooling methods are provided which include providing: one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is also provided to dynamically adjust operation of the N controllable components, based on Z input parameters and one or more specified constraints, and provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.
HydroUnits: A Python-based Physical Units Management Tool in Hydrologic Computing Systems
NASA Astrophysics Data System (ADS)
Celicourt, P.; Piasecki, M.
2015-12-01
While one objective of data management systems is to provide the units when annotating the collected data, another is that the units must be correctly manipulated during conversion steps. This is not a trivial task however and the units conversion time and errors for large datasets can be quite expensive. To date, more than a dozen Python modules have been developed to deal with units attached to quantities. However, they fall short in many ways and also suffer from not integrating with a units controlled vocabulary. Moreover, none of them permits the encoding of some complex units defined in the Consortium of Universities for the Advancement of Hydrologic Sciences, Inc.'s Observations Data Model (CUAHSI ODM) as a vectorial representation for storage demand reduction and does not incorporate provision to accommodate unforeseen standards-based units. We developed HydroUnits, a Python-based units management tool for three specific purposes: encoding of physical units in the Transducer Electronic Data Sheet (TEDS) as defined in the IEEE 1451.0 standard, performing dimensional analysis and on-the-fly conversion of time series allowing users to retrieve data from a data source in a desired equivalent unit while accommodating unforeseen and user-defined units. HydroUnits differentiates itself to existing tools by a number of factors including the implementation approach adopted, the adoption of standard-based units naming conventions and more importantly the emphasis on units controlled vocabularies which are a critical aspect of units treatment. Additionally, HydroUnits supports unit conversion for quantities with additive scaling factor, and natively supports time series conversion and takes leap years into consideration for units consisting of the time dimension (e.g., month, minute). Due to its overall implementation approach, HydroUnits exhibits a high level of versatility that no other tool we are aware of has achieved.
Design of BLDCM emulator for transmission control units
NASA Astrophysics Data System (ADS)
Liu, Chang; He, Yongyi; Zhang, Bodong
2018-04-01
According to the testing requirements of the transmission control unit, a brushless DC motor emulating system is designed based on motor simulation and power hardware-in-the-loop. The discrete motor model is established and a real-time numerical method is designed to solve the motor states. The motor emulator directly interacts with power stage of the transmission control unit using a power-efficient circuit topology and is compatible with sensor-less control. Experiments on a laboratory prototype help to verify that the system can emulate the real motor currents and voltages whenever the motor is starting up or suddenly loaded.
Feed-forward control of a solid oxide fuel cell system with anode offgas recycle
NASA Astrophysics Data System (ADS)
Carré, Maxime; Brandenburger, Ralf; Friede, Wolfgang; Lapicque, François; Limbeck, Uwe; da Silva, Pedro
2015-05-01
In this work a combined heat and power unit (CHP unit) based on the solid oxide fuel cell (SOFC) technology is analysed. This unit has a special feature: the anode offgas is partially recycled to the anode inlet. Thus it is possible to increase the electrical efficiency and the system can be operated without external water feeding. A feed-forward control concept which allows secure operating conditions of the CHP unit as well as a maximization of its electrical efficiency is introduced and validated experimentally. The control algorithm requires a limited number of measurement values and few deterministic relations for its description.
Development of Protection and Control Unit for Distribution Substation
NASA Astrophysics Data System (ADS)
Iguchi, Fumiaki; Hayashi, Hideyuki; Takeuchi, Motohiro; Kido, Mitsuyasu; Kobayashi, Takashi; Yanaoka, Atsushi
The Recently, electronics and IT technologies have been rapidly innovated and have been introduced to power system protection & control system to achieve high reliability, maintainability and more functionality. Concerning the distribution substation application, digital relays have been applied for more than 10 years. Because of a number of electronic devices used for it, product cost becomes higher. Also, products installed during the past high-growth period will be at the end of lifetime and will be replaced. Therefore, replacing market is expected to grow and the reduction of cost is demanded. Considering above mentioned background, second generation digital protection and control unit as a successor is designed to have following concepts. Functional integration based on advanced digital technologies, Ethernet LAN based indoor communication network, cost reduction and downsizing. Pondering above concepts, integration of protection and control function is adopted in contrary to the functional segregation applied to the previous system in order to achieve one-unit concept. Also the adoption of Ethernet LAN for inter-unit communication is objective. This report shows the development of second-generation digital relay for distribution substation, which is equipped with control function and Ethernet LAN by reducing the size of auxiliary transformer unit and the same size as previous product is realized.
Zhao, Hong-Quan; Kasai, Seiya; Shiratori, Yuta; Hashizume, Tamotsu
2009-06-17
A two-bit arithmetic logic unit (ALU) was successfully fabricated on a GaAs-based regular nanowire network with hexagonal topology. This fundamental building block of central processing units can be implemented on a regular nanowire network structure with simple circuit architecture based on graphical representation of logic functions using a binary decision diagram and topology control of the graph. The four-instruction ALU was designed by integrating subgraphs representing each instruction, and the circuitry was implemented by transferring the logical graph structure to a GaAs-based nanowire network formed by electron beam lithography and wet chemical etching. A path switching function was implemented in nodes by Schottky wrap gate control of nanowires. The fabricated circuit integrating 32 node devices exhibits the correct output waveforms at room temperature allowing for threshold voltage variation.
Advances in Enterprise Control. AEC Proceedings, November 15-16, 1999/San Diego, California
1999-11-16
structure of tropical termite mounds. 2.3. Mechanisms that each agent deposits one unit of pheromone per unit time and that a proportion 0 < E < 1 of the...Stubberud 137 Section 4: Distributed and Agent-Based Strategies 149 Synthetic Pheromones for Distributed Motion Control by H. Van Dyke Parunak and...Computer Engineering, June, 1994. 147 148 Section 4 Distributed and Agent-Based Strategies 149 150 Synthetic Pheromones for Distributed Motion
The effect of inquiry based science instruction on student understanding
NASA Astrophysics Data System (ADS)
Nail, Jessica Lynette
According to the TIMSS Study (2007), the United States is falling behind in the subjects of math and science. In order for the students in the United States to develop scientific literacy and remain competitive globally, inquiry must be the priority when teaching science (NRC, 1996; AAAS, 1990). The main purpose of this research was to see if inquiry-based instruction in the science classroom had a significant effect on student understanding and retention of information in a rural school in Virginia. The effect of inquiry-based science instruction on gender was also examined. The researcher implemented a four-week, inquiry-based unit on Virginia Sol 6.7, written in the 5 E learning style to 358 sixth-grade students and compared their posttest gains and delayed posttest scores to a control group consisting of 268 students. The control group received traditional teaching methods. The results for the posttest gains produced a p = 0.01. Therefore, there was a significant difference in the experimental group, which received the treatment, when compared to the control group, which did not receive treatment. A t test was also used to compare the delayed test scores of the experimental group to the control group. The results showed a p < 0.0001 when comparing the experimental group, which received the four-week inquiry-based science instruction treatment, to the control, which did not receive the treatment. This t test showed a very highly significant difference between the experimental group and the control group. Based on these results, it is imperative that Virginia begin implementing inquiry-based instruction in the science classroom.
NASA Astrophysics Data System (ADS)
Zulai, Luis G. T.; Durand, Fábio R.; Abrão, Taufik
2015-05-01
In this article, an energy-efficiency mechanism for next-generation passive optical networks is investigated through heuristic particle swarm optimization. Ten-gigabit Ethernet-wavelength division multiplexing optical code division multiplexing-passive optical network next-generation passive optical networks are based on the use of a legacy 10-gigabit Ethernet-passive optical network with the advantage of using only an en/decoder pair of optical code division multiplexing technology, thus eliminating the en/decoder at each optical network unit. The proposed joint mechanism is based on the sleep-mode power-saving scheme for a 10-gigabit Ethernet-passive optical network, combined with a power control procedure aiming to adjust the transmitted power of the active optical network units while maximizing the overall energy-efficiency network. The particle swarm optimization based power control algorithm establishes the optimal transmitted power in each optical network unit according to the network pre-defined quality of service requirements. The objective is controlling the power consumption of the optical network unit according to the traffic demand by adjusting its transmitter power in an attempt to maximize the number of transmitted bits with minimum energy consumption, achieving maximal system energy efficiency. Numerical results have revealed that it is possible to save 75% of energy consumption with the proposed particle swarm optimization based sleep-mode energy-efficiency mechanism compared to 55% energy savings when just a sleeping-mode-based mechanism is deployed.
Nakarmi, Bikash; Hoai, Tran Quoc; Won, Yong-Hyub; Zhang, Xuping
2014-06-30
We propose and demonstrate a novel scheme for short pulse controlled all-optical switch using external cavity based single mode Fabry- Pérot laser diode (SMFP-LD). The proposed scheme consists of control unit and switching unit as two essential blocks. The basic principle of the proposed scheme is the optical bistability property of SMFP-LD for the control unit and the suppression of the dominant beam of SMFP-LD with injection locking for the switching unit. We also present the analysis of hysteresis width and rising/falling time with change in wavelength detuning which helps to find the optimum wavelength detuning value and power of light beams at different stages of the proposed scheme that gives wide input dynamic power range, high ON/OFF contrast ratio, and low rising/falling time. Input data of 10 Gb/s Non Return to Zero (NRZ) signal is switched at output ports depending upon the control signal generated by the control unit, which comprises of optical SR latch. Output waveforms, clear eye diagrams with extinction ratio of about 11 dB, rising/falling time of about 30 ps and 40 ps, and bit error rate (BER) are measured to validate proposed scheme. No noise floor is observed at output ports up to BER of 10-(12) and the maximum power penalty recorded is about 1.7 dB at a BER of 10-(9) which shows good performance of the proposed short pulse controlled optical switch using SMFP-LDs.
Design and Evaluation of a Fully Implantable Control Unit for Blood Pumps
Unthan, Kristin; Gräf, Felix; Laumen, Marco; Finocchiaro, Thomas; Sommer, Christoph; Lanmüller, Hermann; Steinseifer, Ulrich
2015-01-01
As the number of donor hearts is limited while more and more patients suffer from end stage biventricular heart failure, Total Artificial Hearts become a promising alternative to conventional treatment. While pneumatic devices sufficiently supply the patients with blood flow, the patient's quality of life is limited by the percutaneous pressure lines and the size of the external control unit. This paper describes the development of the control unit of the ReinHeart, a fully implantable Total Artificial Heart. General requirements for any implantable control unit are defined from a technical and medical point of view: necessity of a Transcutaneous Energy Transmission, autonomous operation, safety, geometry, and efficiency. Based on the requirements, a prototype is designed; it incorporates a LiFePo4 battery pack with charger, a rectifier for transcutaneous energy transmission, the motor's driver electronics, and a microcontroller which monitors and controls all functions. In validation tests, the control unit demonstrated a stable operation on TET and battery supply and a safe switching from one supply to the other. The overall mean efficiency is 14% on TET and 22% on battery supply. The control unit is suitable for chronic animal trials of the ReinHeart. PMID:26583095
Mathematical modeling of control system for the experimental steam generator
NASA Astrophysics Data System (ADS)
Podlasek, Szymon; Lalik, Krzysztof; Filipowicz, Mariusz; Sornek, Krzysztof; Kupski, Robert; Raś, Anita
2016-03-01
A steam generator is an essential unit of each cogeneration system using steam machines. Currently one of the cheapest ways of the steam generation can be application of old steam generators came from army surplus store. They have relatively simple construction and in case of not so exploited units - quite good general conditions, and functionality of mechanical components. By contrast, electrical components and control systems (mostly based on relay automatics) are definitely obsolete. It is not possible to use such units with cooperation of steam bus or with steam engines. In particular, there is no possibility for automatically adjustment of the pressure and the temperature of the generated steam supplying steam engines. Such adjustment is necessary in case of variation of a generator load. The paper is devoted to description of improvement of an exemplary unit together with construction of the measurement-control system based on a PLC. The aim was to enable for communication between the steam generator and controllers of the steam bus and steam engines in order to construction of a complete, fully autonomic and maintenance-free microcogeneration system.
An Unconventional Inchworm Actuator Based on PZT/ERFs Control Technology
Liu, Guojun; Zhang, Yanyan; Liu, Jianfang; Li, Jianqiao; Tang, Chunxiu; Wang, Tengfei; Yang, Xuhao
2016-01-01
An unconventional inchworm actuator for precision positioning based on piezoelectric (PZT) actuation and electrorheological fluids (ERFs) control technology is presented. The actuator consists of actuation unit (PZT stack pump), fluid control unit (ERFs valve), and execution unit (hydraulic actuator). In view of smaller deformation of PZT stack, a new structure is designed for actuation unit, which integrates the advantages of two modes (namely, diaphragm type and piston type) of the volume changing of pump chamber. In order to improve the static shear yield strength of ERFs, a composite ERFs valve is designed, which adopts the series-parallel plate compound structure. The prototype of the inchworm actuator has been designed and manufactured in the lab. Systematic test results indicate that the displacement resolution of the unconventional inchworm actuator reaches 0.038 μm, and the maximum driving force and velocity are 42 N, 14.8 mm/s, respectively. The optimal working frequency for the maximum driving velocity is 120 Hz. The complete research and development processes further confirm the feasibility of developing a new type of inchworm actuator with high performance based on PZT actuation and ERFs control technology, which provides a reference for the future development of a new type of actuator. PMID:27022234
An Unconventional Inchworm Actuator Based on PZT/ERFs Control Technology.
Liu, Guojun; Zhang, Yanyan; Liu, Jianfang; Li, Jianqiao; Tang, Chunxiu; Wang, Tengfei; Yang, Xuhao
2016-01-01
An unconventional inchworm actuator for precision positioning based on piezoelectric (PZT) actuation and electrorheological fluids (ERFs) control technology is presented. The actuator consists of actuation unit (PZT stack pump), fluid control unit (ERFs valve), and execution unit (hydraulic actuator). In view of smaller deformation of PZT stack, a new structure is designed for actuation unit, which integrates the advantages of two modes (namely, diaphragm type and piston type) of the volume changing of pump chamber. In order to improve the static shear yield strength of ERFs, a composite ERFs valve is designed, which adopts the series-parallel plate compound structure. The prototype of the inchworm actuator has been designed and manufactured in the lab. Systematic test results indicate that the displacement resolution of the unconventional inchworm actuator reaches 0.038 μm, and the maximum driving force and velocity are 42 N, 14.8 mm/s, respectively. The optimal working frequency for the maximum driving velocity is 120 Hz. The complete research and development processes further confirm the feasibility of developing a new type of inchworm actuator with high performance based on PZT actuation and ERFs control technology, which provides a reference for the future development of a new type of actuator.
Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan
2017-08-01
In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.
The Control Unit of KM3NeT data acquisition
NASA Astrophysics Data System (ADS)
Bozza, Cristiano
2016-04-01
The KM3NeT Collaboration is building a new generation of neutrino telescopes in the Mediterranean Sea. With the telescopes, scientists will search for cosmic neutrinos to study highly energetic objects in the Universe, while one neutrino detector will be dedicated to measure the properties of the high-energy neutrino particles themselves. Control of the KM3NeT data acquisition processes is handled by the KM3NeT Control Unit, which has been designed to maximise the detector live time. The Control Unit features software programs with different roles, following the philosophy of having no single point of failure. While all programs are interconnected, each one can also work alone for most of the time in case other services are unavailable. All services run on the Common Language Runtime, which ensures portability, flexibility and automatic memory management. Each service has an embedded Web server, providing a user interface as well as programmatic access to data and functions. Data to and from detector components for monitoring and management purposes are transmitted using a custom designed protocol. The Control Unit is interfaced to one or more Message Dispatchers to control the data acquisition chain. A Data Base Interface provides fast and fault-tolerant connection to a remote Data Base.
He, Feng Jie; Liu, Hui Long; Chen, Long Cong; Xiong, Xing Liang
2018-03-01
Liquid crystal (LC)-based sensors have the advantageous properties of being fast, sensitive, and label-free, the results of which can be accessed directly only through the naked eye. However, the inherent disadvantages possessed by LC sensors, such as relying heavily on polarizing microscopes and the difficulty to quantify, have limited the possibility of field applications. Herein, we have addressed these issues by constructing a portable polarized detection system with constant temperature control. This system is mainly composed of four parts: the LC cell, the optics unit, the automatic temperature control unit, and the image processing unit. The LC cell was based on the ordering transitions of LCs in the presence of analytes. The optics unit based on the imaging principle of LCs was designed to substitute the polarizing microscope for the real-time observation. The image processing unit is expected to quantify the concentration of analytes. The results have shown that the presented system can detect dimethyl methyl phosphonate (a stimulant for organophosphorus nerve gas) within 25 s, and the limit of detection is about 10 ppb. In all, our portable system has potential in field applications.
NASA Astrophysics Data System (ADS)
He, Feng Jie; Liu, Hui Long; Chen, Long Cong; Xiong, Xing Liang
2018-03-01
Liquid crystal (LC)-based sensors have the advantageous properties of being fast, sensitive, and label-free, the results of which can be accessed directly only through the naked eye. However, the inherent disadvantages possessed by LC sensors, such as relying heavily on polarizing microscopes and the difficulty to quantify, have limited the possibility of field applications. Herein, we have addressed these issues by constructing a portable polarized detection system with constant temperature control. This system is mainly composed of four parts: the LC cell, the optics unit, the automatic temperature control unit, and the image processing unit. The LC cell was based on the ordering transitions of LCs in the presence of analytes. The optics unit based on the imaging principle of LCs was designed to substitute the polarizing microscope for the real-time observation. The image processing unit is expected to quantify the concentration of analytes. The results have shown that the presented system can detect dimethyl methyl phosphonate (a stimulant for organophosphorus nerve gas) within 25 s, and the limit of detection is about 10 ppb. In all, our portable system has potential in field applications.
C2 of C3: Command and Control of Command, Control, Communication Systems.
1988-04-22
capabilities the Army has not yet realized the full benefit of the new technology--largely because of deficiencies in the operational management of these newly...managers frequently constructed CEOI’s by drawing available frequencies or letter/number combinations (for unit callsigns) from a Bingo creel--which was...rapidly occurring changes, with subordinate units. At last, units were beginning to see the benefits of operating from a commonly shared data base. Up to
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-17
... Reconfiguration and Base Perimeter Fence Relocation in area A Wright-Patterson AF Base, Ohio, Final Environmental..., 2012, the United States Air Force signed the ROD for the Entry Control Reconfiguration and Base Perimeter Fence Relocation in Area A Wright-Patterson Air Force Base (WPAFB), Ohio Final Environmental...
NASA Technical Reports Server (NTRS)
Shaver, Charles; Williamson, Michael
1986-01-01
The NASA Ames Research Center sponsors a research program for the investigation of Intelligent Flight Control Actuation systems. The use of artificial intelligence techniques in conjunction with algorithmic techniques for autonomous, decentralized fault management of flight-control actuation systems is explored under this program. The design, development, and operation of the interface for laboratory investigation of this program is documented. The interface, architecturally based on the Intel 8751 microcontroller, is an interrupt-driven system designed to receive a digital message from an ultrareliable fault-tolerant control system (UFTCS). The interface links the UFTCS to an electronic servo-control unit, which controls a set of hydraulic actuators. It was necessary to build a UFTCS emulator (also based on the Intel 8751) to provide signal sources for testing the equipment.
Information management system breadboard data acquisition and control system.
NASA Technical Reports Server (NTRS)
Mallary, W. E.
1972-01-01
Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.
Integrated optics reflectometer
Couch, Philip R; Murphy, Kent A.; Gunther, Michael F; Gause, Charles B
2017-01-31
An apparatus includes a laser source configured to output laser light at a target frequency, and a measurement unit configured to measure a deviation between an actual frequency outputted by the laser source at a current period of time and the target frequency of the laser source. The apparatus includes a feedback control unit configured to, based on the measured deviation between the actual and target frequencies, control the laser source to maintain a constant frequency of laser output from the laser source so that the frequency of laser light transmitted from the laser source is adjusted to the target frequency. The feedback control unit can control the laser source to maintain a linear rate of change in the frequency of its laser light output, and compensate for characteristics of the measurement unit utilized for frequency measurement. A method is provided for performing the feedback control of the laser source.
1998-05-01
ROG reactive organic compound RONA Record of Non -applicability RTV rational threshold value RWQCB Regional Water Quality Control Board SARA...over water. The ranges are either scheduled via a designated military or civilian controlling agency (for restricted or warning areas) or are used...operations areas (MOAs), and air traffic control authorized airspace (ATCAA). Airspace designations throughout the United States are controlled by the Federal
FLUX-BASED METHODS FOR DNAPL REMEDIATION DESIGN AND ASSESSMENT
One tool that has been investigated for use in DNAPL site characterization and remediation is mass flux (mass per unit area per unit time) and mass discharge (mass per unit time) measurements. These measurements, when collected across one or more control planes located down grad...
How reliable are odour assessments?
Bokowa, A; Beukes, J A
2012-01-01
This paper will demonstrate the differences found in odour test results, when odour sampling is performed at the same sources by two different consultants. By examining two case studies, this paper will highlight that the difference between the results can be significant. Both studies are based on odour sampling programs determining the odour removal efficiency of odour control units installed at two different facilities: a pet food facility and an oil/grease recycling facility. The first study is based on odour measurements at the inlet and outlet of the unit installed by Applied Plasma Physics AS at the pet food facility. Odour assessments were performed by two separate consultants at the same time. The second study is based on testing of the odour removal effectiveness of two units: a scrubber and a biofilter at an oil/grease recycling facility. During this study two odour sampling programs were performed by two consultants at different times, but under the same process conditions. This paper will show how varying results can play a role in choosing the adequate odour control technologies. The final results suggest that although, an odour control unit may appear to be insufficient, it actually is successful at removing the odours.
A coordinated MIMO control design for a power plant using improved sliding mode controller.
Ataei, Mohammad; Hooshmand, Rahmat-Allah; Samani, Siavash Golmohammadi
2014-03-01
For the participation of the steam power plants in regulating the network frequency, boilers and turbines should be co-ordinately controlled in addition to the base load productions. Lack of coordinated control over boiler-turbine may lead to instability; oscillation in producing power and boiler parameters; reduction in the reliability of the unit; and inflicting thermodynamic tension on devices. This paper proposes a boiler-turbine coordinated multivariable control system based on improved sliding mode controller (ISMC). The system controls two main boiler-turbine parameters i.e., the turbine revolution and superheated steam pressure of the boiler output. For this purpose, a comprehensive model of the system including complete and exact description of the subsystems is extracted. The parameters of this model are determined according to our case study that is the 320MW unit of Islam-Abad power plant in Isfahan/Iran. The ISMC method is simulated on the power plant and its performance is compared with the related real PI (proportional-integral) controllers which have been used in this unit. The simulation results show the capability of the proposed controller system in controlling local network frequency and superheated steam pressure in the presence of load variations and disturbances of boiler. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Bricklaying Curriculum: Advanced Bricklaying Techniques. Instructional Materials. Revised.
ERIC Educational Resources Information Center
Turcotte, Raymond J.; Hendrix, Laborn J.
This curriculum guide is designed to assist bricklaying instructors in providing performance-based instruction in advanced bricklaying. Included in the first section of the guide are units on customized or architectural masonry units; glass block; sills, lintels, and copings; and control (expansion) joints. The next two units deal with cut,…
Matching of energetic, mechanic and control characteristics of positioning actuator
NASA Astrophysics Data System (ADS)
Y Nosova, N.; Misyurin, S. Yu; Kreinin, G. V.
2017-12-01
The problem of preliminary choice of parameters of the automated drive power channel is discussed. The drive of the mechatronic complex divides into two main units - power and control. The first determines the energy capabilities and, as a rule, the overall dimensions of the complex. The sufficient capacity of the power unit is a necessary condition for successful solution of control tasks without excessive complication of the control system structure. Preliminary selection of parameters is carried out based on the condition of providing the necessary drive power. The proposed approach is based on: a research of a sufficiently developed but not excessive dynamic model of the power block with the help of a conditional test control system; a transition to a normalized model with the formation of similarity criteria; constructing the synthesis procedure.
Rail inspection system based on iGPS
NASA Astrophysics Data System (ADS)
Fu, Xiaoyan; Wang, Mulan; Wen, Xiuping
2018-05-01
Track parameters include gauge, super elevation, cross level and so on, which could be calculated through the three-dimensional coordinates of the track. The rail inspection system based on iGPS (indoor/infrared GPS) was composed of base station, receiver, rail inspection frame, wireless communication unit, display and control unit and data processing unit. With the continuous movement of the inspection frame, the system could accurately inspect the coordinates of rail; realize the intelligent detection and precision measurement. According to principle of angle intersection measurement, the inspection model was structured, and detection process was given.
Wu, Dan; Xu, Yuan; Zhang, Shiqiu
2015-02-01
By following an empirical approach, this study proves that joint regional air pollution control (JRAPC) in the Beijing-Tianjin-Hebei region will save the expense on air pollution control compared with a locally-based pollution control strategy. The evidences below were found. (A) Local pollutant concentration in some of the cities is significantly affected by emissions from their surrounding areas. (B) There is heterogeneity in the marginal pollutant concentration reduction cost among various districts as a result of the cities' varying contribution of unit emission reduction to the pollutant concentration reduction, and their diverse unit cost of emission reduction brought about by their different industry composition. The results imply that the cost-efficiency of air pollution control will be improved in China if the conventional locally based regime of air pollution control can shift to a regionally based one. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Two Axis Pointing System (TAPS) attitude acquisition, determination, and control
NASA Technical Reports Server (NTRS)
Azzolini, John D.; Mcglew, David E.
1990-01-01
The Two Axis Pointing System (TAPS) is a 2 axis gimbal system designed to provide fine pointing of Space Transportation System (STS) borne instruments. It features center-of-mass instrument mounting and will accommodate instruments of up to 1134 kg (2500 pounds) which fit within a 1.0 by 1.0 by 4.2 meter (40 by 40 by 166 inch) envelope. The TAPS system is controlled by a microcomputer based Control Electronics Assembly (CEA), a Power Distribution Unit (PDU), and a Servo Control Unit (SCU). A DRIRU-II inertial reference unit is used to provide incremental angles for attitude propagation. A Ball Brothers STRAP star tracker is used for attitude acquisition and update. The theory of the TAPS attitude determination and error computation for the Broad Band X-ray Telescope (BBXRT) are described. The attitude acquisition is based upon a 2 star geometric solution. The acquisition theory and quaternion algebra are presented. The attitude control combines classical position, integral and derivative (PID) control with techniques to compensate for coulomb friction (bias torque) and the cable harness crossing the gimbals (spring torque). Also presented is a technique for an adaptive bias torque compensation which adjusts to an ever changing frictional torque environment. The control stability margins are detailed, with the predicted pointing performance, based upon simulation studies. The TAPS user interface, which provides high level operations commands to facilitate science observations, is outlined.
Academic Quality Control: The Case of College Programs on Military Bases.
ERIC Educational Resources Information Center
Bailey, Stephen K.
The quality of college programs at 13 U.S. military bases and the activities of various agencies for maintaining quality control were evaluated. Based on site visits to military bases in the continental United States and Hawaii in 1978, some academic programs appeared to have few standards and practices that promote quality. It is claimed that…
Nutaro, James J.; Fugate, David L.; Kuruganti, Teja; ...
2015-05-27
We describe a cost-effective retrofit technology that uses collective control of multiple rooftop air conditioning units to reduce the peak power consumption of small and medium commercial buildings. The proposed control uses a model of the building and air conditioning units to select an operating schedule for the air conditioning units that maintains a temperature set point subject to a constraint on the number of units that may operate simultaneously. A prototype of this new control system was built and deployed in a large gymnasium to coordinate four rooftop air conditioning units. Based on data collected while operating this prototype,more » we estimate that the cost savings achieved by reducing peak power consumption is sufficient to repay the cost of the prototype within a year.« less
Advanced Electric Distribution, Switching, and Conversion Technology for Power Control
NASA Technical Reports Server (NTRS)
Soltis, James V.
1998-01-01
The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.
Ezra, Elishai; Maor, Idan; Bavli, Danny; Shalom, Itai; Levy, Gahl; Prill, Sebastian; Jaeger, Magnus S; Nahmias, Yaakov
2015-08-01
Microfluidic applications range from combinatorial synthesis to high throughput screening, with platforms integrating analog perfusion components, digitally controlled micro-valves and a range of sensors that demand a variety of communication protocols. Currently, discrete control units are used to regulate and monitor each component, resulting in scattered control interfaces that limit data integration and synchronization. Here, we present a microprocessor-based control unit, utilizing the MS Gadgeteer open framework that integrates all aspects of microfluidics through a high-current electronic circuit that supports and synchronizes digital and analog signals for perfusion components, pressure elements, and arbitrary sensor communication protocols using a plug-and-play interface. The control unit supports an integrated touch screen and TCP/IP interface that provides local and remote control of flow and data acquisition. To establish the ability of our control unit to integrate and synchronize complex microfluidic circuits we developed an equi-pressure combinatorial mixer. We demonstrate the generation of complex perfusion sequences, allowing the automated sampling, washing, and calibrating of an electrochemical lactate sensor continuously monitoring hepatocyte viability following exposure to the pesticide rotenone. Importantly, integration of an optical sensor allowed us to implement automated optimization protocols that require different computational challenges including: prioritized data structures in a genetic algorithm, distributed computational efforts in multiple-hill climbing searches and real-time realization of probabilistic models in simulated annealing. Our system offers a comprehensive solution for establishing optimization protocols and perfusion sequences in complex microfluidic circuits.
Leccese, Fabio; Cagnetti, Marco; Trinca, Daniele
2014-01-01
A smart city application has been realized and tested. It is a fully remote controlled isle of lamp posts based on new technologies. It has been designed and organized in different hierarchical layers, which perform local activities to physically control the lamp posts and transmit information with another for remote control. Locally, each lamp post uses an electronic card for management and a ZigBee tlc network transmits data to a central control unit, which manages the whole isle. The central unit is realized with a Raspberry-Pi control card due to its good computing performance at very low price. Finally, a WiMAX connection was tested and used to remotely control the smart grid, thus overcoming the distance limitations of commercial Wi-Fi networks. The isle has been realized and tested for some months in the field. PMID:25529206
Leccese, Fabio; Cagnetti, Marco; Trinca, Daniele
2014-12-18
A smart city application has been realized and tested. It is a fully remote controlled isle of lamp posts based on new technologies. It has been designed and organized in different hierarchical layers, which perform local activities to physically control the lamp posts and transmit information with another for remote control. Locally, each lamp post uses an electronic card for management and a ZigBee tlc network transmits data to a central control unit, which manages the whole isle. The central unit is realized with a Raspberry-Pi control card due to its good computing performance at very low price. Finally, a WiMAX connection was tested and used to remotely control the smart grid, thus overcoming the distance limitations of commercial Wi-Fi networks. The isle has been realized and tested for some months in the field.
Collective actors and corporate targets in tobacco control: a cross-national comparison.
Nathanson, Constance A
2005-06-01
Cross-national comparative analysis of tobacco control strategies can alert health advocates to how opportunities for public health action, types of action, and probabilities for success are shaped by political systems and cultures. This article is based on case studies of tobacco control in the United States, Canada, Britain, and France. Two questions are addressed: (a) To whom were the dangers of smoking attributed? and (b) What was the role of collective action--grassroots level organization--in combating these dangers? Activists in Canada, Britain, and France moved earlier than the United States did to target the tobacco industry and the state. Locally based advocacy centered on passive smoking has been far more important in the United States. The author concludes that U.S.-style advocacy has played a major role in this country's smoking decline but is insufficient in and of itself to change the corporate practices of a wealthy and politically powerful industry.
Service equipment for use in hostile environments
NASA Technical Reports Server (NTRS)
Dolce, James L. (Inventor); Gordon, Andrew L. (Inventor)
1994-01-01
Service equipment for use in hostile environments includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit and stationary unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.
An extensible, low-cost drifter control unit
NASA Astrophysics Data System (ADS)
Giudici, Andrea; Torsvik, Tomas; Soomere, Tarmo
2017-04-01
We introduce an extensible, low-cost drifter control unit, which is developed for use with surface drifters that are deployed in inland water bodies or near-coast regions. The control unit is custom-built on top of a small footprint micro controller. It makes use of a GPS receiver for position tracking, a GSM radio for data transmission, and two sensor buses to handle analog and digital data measured by an array of external sensors. A cloud-based data collection platform receives and stores the data transmitted over GPRS from the drifter. The control unit was found to perform satisfactorily in operational testing, providing data at sub-Hz frequency for position and temperature during extended time. Test deployments revealed some issues related to power consumption spikes. Even though the unit is fully functional in the present form and shows, on average, low energy consumption , battery packs with relatively large maximum output power are required to ensure its operation within prolonged periods of time. We expect that a further development of the power supply unit together with a careful de-synchronization scheme of sensors' operation would smooth those peaks without any loss of the quality of recorded information.
DeJournett, Leon; DeJournett, Jeremy
2016-01-01
Background: Effective glucose control in the intensive care unit (ICU) setting has the potential to decrease morbidity and mortality rates which should in turn lead to decreased health care expenditures. Current ICU-based glucose controllers are mathematically derived, and tend to be based on proportional integral derivative (PID) or model predictive control (MPC). Artificial intelligence (AI)–based closed loop glucose controllers may have the ability to achieve control that improves on the results achieved by either PID or MPC controllers. Method: We conducted an in silico analysis of an AI-based glucose controller designed for use in the ICU setting. This controller was tested using a mathematical model of the ICU patient’s glucose-insulin system. A total of 126 000 unique 5-day simulations were carried out, resulting in 107 million glucose values for analysis. Results: For the 7 control ranges tested, with a sensor error of ±10%, the following average results were achieved: (1) time in control range, 94.2%, (2) time in range 70-140 mg/dl, 97.8%, (3) time in hyperglycemic range (>140 mg/dl), 2.1%, and (4) time in hypoglycemic range (<70 mg/dl), 0.09%. In addition, the average coefficient of variation (CV) was 11.1%. Conclusions: This in silico study of an AI-based closed loop glucose controller shows that it may be able to improve on the results achieved by currently existing ICU-based PID/MPC controllers. If these results are confirmed in clinical testing, this AI-based controller could be used to create an artificial pancreas system for use in the ICU setting. PMID:27301982
DeJournett, Leon; DeJournett, Jeremy
2016-11-01
Effective glucose control in the intensive care unit (ICU) setting has the potential to decrease morbidity and mortality rates which should in turn lead to decreased health care expenditures. Current ICU-based glucose controllers are mathematically derived, and tend to be based on proportional integral derivative (PID) or model predictive control (MPC). Artificial intelligence (AI)-based closed loop glucose controllers may have the ability to achieve control that improves on the results achieved by either PID or MPC controllers. We conducted an in silico analysis of an AI-based glucose controller designed for use in the ICU setting. This controller was tested using a mathematical model of the ICU patient's glucose-insulin system. A total of 126 000 unique 5-day simulations were carried out, resulting in 107 million glucose values for analysis. For the 7 control ranges tested, with a sensor error of ±10%, the following average results were achieved: (1) time in control range, 94.2%, (2) time in range 70-140 mg/dl, 97.8%, (3) time in hyperglycemic range (>140 mg/dl), 2.1%, and (4) time in hypoglycemic range (<70 mg/dl), 0.09%. In addition, the average coefficient of variation (CV) was 11.1%. This in silico study of an AI-based closed loop glucose controller shows that it may be able to improve on the results achieved by currently existing ICU-based PID/MPC controllers. If these results are confirmed in clinical testing, this AI-based controller could be used to create an artificial pancreas system for use in the ICU setting. © 2016 Diabetes Technology Society.
Development of a Power Electronics Unit for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Hamley, John A.; Hill, Gerald M.; Patterson, Michael J.; Saggio, Joseph, Jr.; Terdan, Fred; Mansell, Justin D.
1994-01-01
A hollow cathode plasma contactor has been baselined as a charge control device for the Space Station (SS) to prevent deleterious interactions of coated structural components with the ambient plasma. NASA LeRC Work Package 4 initiated the development of a plasma contactor system comprised of a Power Electronics Unit (PEU), an Expellant Management Unit (EMU), a command and data interface, and a Plasma Contactor Unit (PCU). A breadboard PEU was designed and fabricated. The breadboard PEU contains a cathode heater and discharge power supply, which were required to operate the PCU, a control and auxiliary power converter, an EMU interface, a command and telemetry interface, and a controller. The cathode heater and discharge supplies utilized a push-pull topology with a switching frequency of 20 kHz and pulse-width-modulated (PWM) control. A pulse ignition circuit derived from that used in arcjet power processors was incorporated in the discharge supply for discharge ignition. An 8088 based microcontroller was utilized in the breadboard model to provide a flexible platform for controller development with a simple command/data interface incorporating a direct connection to SS Mulitplexer/Demultiplexer (MDM) analog and digital I/O cards. Incorporating this in the flight model would eliminate the hardware and software overhead associated with a 1553 serial interface. The PEU autonomously operated the plasma contactor based on command inputs and was successfully integrated with a prototype plasma contactor unit demonstrating reliable ignition of the discharge and steady-state operation.
Wireless Control of Miniaturized Mobile Vehicle for Indoor Surveillance
NASA Astrophysics Data System (ADS)
Taha Saquib, Syed M.; Hameed, Sarmad; Usman Ali, Syed M.; Jafri, Raza; Amin, Imran
2013-12-01
This work is based upon electronic automation and Smart Control techniques, which constitute the basis of Control Area Network (CAN) and Personal Area Network (PAN). Bluetooth technology has been interfaced with a programmable controller to provide multi-dimensional vehicle control. A network is proposed which contains a remote, mobile host controller and an android operating system based mobile set (Client). The client communicates with a host controller through a Bluetooth device. The system incorporates duplex communication after successful confirmation between the host and the client; the android based mobile unit controls the vehicle through the Bluetooth module.
In Search of Effective Solutions to Curb Workplace Violence.
Arnetz, Judith; Lipscomb, Jane; Ogaitis, Joanne
2017-04-01
Investigators have applied epidemiological principles to the study of workplace violence, producing results that offer intriguing information to hospitals struggling for a way forward on this issue. In a randomized, to hospitals struggling for a wary forward on this issue. In a randomized, controlled trial, the researchers found that a one-time, unit-based intervention can reduce the incidence of violent events, and that the approach offers some lasting effect over time. The intervention consisted of a 45-minute discussion with unit supervisors in which unit-specific data regarding violent incidents in their workplace were shared along with an array of improvement strategies. Unit supervisors then were directed to work with their teams to develop action plans to address violence, although they were free to adopt whatever solutions they deemed best. At six moths post-intervention, there was a clear reduction in the incident rate ratios of violent events on the intervention units as compared with control units that did not conduct an intervention. Experts note that the study demonstrates that an effective workplace violence intervention or program must be data-driven and based on principles of continuous quality improvement.
NASA Technical Reports Server (NTRS)
Rickard, D. A.; Bodenheimer, R. E.
1976-01-01
Digital computer components which perform two dimensional array logic operations (Tse logic) on binary data arrays are described. The properties of Golay transforms which make them useful in image processing are reviewed, and several architectures for Golay transform processors are presented with emphasis on the skeletonizing algorithm. Conventional logic control units developed for the Golay transform processors are described. One is a unique microprogrammable control unit that uses a microprocessor to control the Tse computer. The remaining control units are based on programmable logic arrays. Performance criteria are established and utilized to compare the various Golay transform machines developed. A critique of Tse logic is presented, and recommendations for additional research are included.
RF control hardware design for CYCIAE-100 cyclotron
NASA Astrophysics Data System (ADS)
Yin, Zhiguo; Fu, Xiaoliang; Ji, Bin; Zhao, Zhenlu; Zhang, Tianjue; Li, Pengzhan; Wei, Junyi; Xing, Jiansheng; Wang, Chuan
2015-11-01
The Beijing Radioactive Ion-beam Facility project is being constructed by BRIF division of China Institute of Atomic Energy. In this project, a 100 MeV high intensity compact proton cyclotron is built for multiple applications. The first successful beam extraction of CYCIAE-100 cyclotron was done in the middle of 2014. The extracted proton beam energy is 100 MeV and the beam current is more than 20 μA. The RF system of the CYCIAE-100 cyclotron includes two half-wavelength cavities, two 100 kW tetrode amplifiers and power transmission line systems (all above are independent from each other) and two sets of Low Level RF control crates. Each set of LLRF control includes an amplitude control unit, a tuning control unit, a phase control unit, a local Digital Signal Process control unit and an Advanced RISC Machines based EPICS IOC unit. These two identical LLRF control crates share one common reference clock and take advantages of modern digital technologies (e.g. DSP and Direct Digital Synthesizer) to achieve closed loop voltage and phase regulations of the dee-voltage. In the beam commission, the measured dee-voltage stability of RF system is better than 0.1% and phase stability is better than 0.03°. The hardware design of the LLRF system will be reviewed in this paper.
NASA Astrophysics Data System (ADS)
Kumar, T. S.
2016-08-01
In this paper, we describe the details of control unit and GUI software for positioning two filter wheels, a slit wheel and a grism wheel in the ADFOSC instrument. This is a first generation instrument being built for the 3.6 m Devasthal optical telescope. The control hardware consists of five electronic boards based on low cost 8-bit PIC microcontrollers and are distributed over I2C bus. The four wheels are controlled by four identical boards which are configured in I2C slave mode while the fifth board acts as an I2C master for sending commands to and receiving status from the slave boards. The master also communicates with the interfacing PC over TCP/IP protocol using simple ASCII commands. For moving the wheels stepper motors along with suitable amplifiers have been employed. Homing after powering ON is achieved using hall effect sensors. By implementing distributed control units having identical design modularity is achieved enabling easier maintenance and upgradation. A GUI based software for commanding the instrument is developed in Microsoft Visual C++. For operating the system during observations the user selects normal mode while the engineering mode is available for offering additional flexibility and low level control during maintenance and testing. A detailed time-stamped log of commands, status and errors are continuously generated. Both the control unit and the software have been successfully tested and integrated with the ADFOSC instrument.
NASA Astrophysics Data System (ADS)
Huang, Lei; Zhou, Chenlu; Zhao, Wenchuan; Choi, Heejoo; Graves, Logan; Kim, Daewook
2017-06-01
We present a high precision deflectometry system (DS) controlled deformable mirror (DM) solution for optical system. Different from wavefront and non-wavefront system, the DS and the DM are set to be an individual integrated DCDM unit and can be installed in one base plate. In the DCDM unit, the DS can directly provide the influence functions and surface shape of the DM to the industrial computer in any adaptive optics system. As an integrated adaptive unit, the DCDM unit could be put into various optical systems to realize aberration compensation. In this paper, the configuration and principle of the DCDM unit is introduced first. Theoretical simulation on the close-loop performance of the DCDM unit is carried out. Finally, a verification experiment is proposed to verify the compensation capability of the DCDM unit.
47 CFR 90.475 - Operation of internal transmitter control systems in specially equipped systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... systems involving fixed systems whose base stations are controlled by such systems may automatically access these base stations through the microwave or operational fixed systems from positions in the PSTN, so long as the base stations and mobile units meet the requirements of § 90.483 and if a separate...
Liu, Yecai; Posey, Drew L; Cetron, Martin S; Painter, John A
2015-03-17
Before 2007, immigrants and refugees bound for the United States were screened for tuberculosis (TB) by a smear-based algorithm that could not diagnose smear-negative/culture-positive TB. In 2007, the Centers for Disease Control and Prevention implemented a culture-based algorithm. To evaluate the effect of the culture-based algorithm on preventing the importation of TB to the United States by immigrants and refugees from foreign countries. Population-based, cross-sectional study. Panel physician sites for overseas medical examination. Immigrants and refugees with TB. Comparison of the increase of smear-negative/culture-positive TB cases diagnosed overseas among immigrants and refugees by the culture-based algorithm with the decline of reported cases among foreign-born persons within 1 year after arrival in the United States from 2007 to 2012. Of the 3 212 421 arrivals of immigrants and refugees from 2007 to 2012, a total of 1 650 961 (51.4%) were screened by the smear-based algorithm and 1 561 460 (48.6%) were screened by the culture-based algorithm. Among the 4032 TB cases diagnosed by the culture-based algorithm, 2195 (54.4%) were smear-negative/culture-positive. Before implementation (2002 to 2006), the annual number of reported cases among foreign-born persons within 1 year after arrival was relatively constant (range, 1424 to 1626 cases; mean, 1504 cases) but decreased from 1511 to 940 cases during implementation (2007 to 2012). During the same period, the annual number of smear-negative/culture-positive TB cases diagnosed overseas among immigrants and refugees bound for the United States by the culture-based algorithm increased from 4 to 629. This analysis did not control for the decline in new arrivals of nonimmigrant visitors to the United States and the decrease of incidence of TB in their countries of origin. Implementation of the culture-based algorithm may have substantially reduced the incidence of TB among newly arrived, foreign-born persons in the United States. None.
McKinney, P A; Feltbower, R G; Stephenson, C R; Reynolds, C
2008-11-01
To provide a population-based clinical audit of children and young people with diabetes, reporting outcomes, including glycaemic control, for named individual units. Clinical audit data on care processes and glycated haemoglobin (HbA(1c)) were collected for 1742 children and young people treated in 16 paediatric units in Yorkshire, from January 2005 to March 2006. The Yorkshire Register of Diabetes in Children and Young People provided information technology support and validation that enhanced data quality. Multi-level linear regression modelling investigated factors affecting glycaemic control. An HbA(1c) measure was recorded for 91.6% of patients. The National Institute for Clinical Excellence-recommended target level for HbA(1c) of < 7.5% was achieved for 14.7% of patients. HbA(1c) was positively associated with duration of diabetes and later age at diagnosis. Patients living in deprived areas had significantly poorer control compared with those from affluent areas. Significant between-unit variation in HbA(1c) was not reflected by any association with unit size. Our population-based clinical audit of children with diabetes is the product of an effective collaboration between those who deliver care and health services researchers. High levels of recording the key care process measuring diabetes control, compared with national figures, suggests collaboration has translated into improved services. The interesting association between poor diabetes control and higher deprivation is noteworthy and requires further investigation. Future audits require recording of clinical management and clinic structures, in addition to resources to record, assemble and analyse data.
Designing the next generation of robotic controllers
NASA Technical Reports Server (NTRS)
Goldstein, David G.
1994-01-01
The use of scenario-based, object-oriented software engineering methodologies in the next generation of robotic controllers is discussed. The controllers are intended to supplant the decades old technology currently embraced by the manufacturing industry of the United States.
Romanò, Carlo L; Monti, Lorenzo; Logoluso, Nicola; Romanò, Delia; Drago, Lorenzo
2015-11-01
The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. II.
NASA Astrophysics Data System (ADS)
Leung, Nelson; Abdelhafez, Mohamed; Koch, Jens; Schuster, David
2017-04-01
We implement a quantum optimal control algorithm based on automatic differentiation and harness the acceleration afforded by graphics processing units (GPUs). Automatic differentiation allows us to specify advanced optimization criteria and incorporate them in the optimization process with ease. We show that the use of GPUs can speedup calculations by more than an order of magnitude. Our strategy facilitates efficient numerical simulations on affordable desktop computers and exploration of a host of optimization constraints and system parameters relevant to real-life experiments. We demonstrate optimization of quantum evolution based on fine-grained evaluation of performance at each intermediate time step, thus enabling more intricate control on the evolution path, suppression of departures from the truncated model subspace, as well as minimization of the physical time needed to perform high-fidelity state preparation and unitary gates.
PID Controller Settings Based on a Transient Response Experiment
ERIC Educational Resources Information Center
Silva, Carlos M.; Lito, Patricia F.; Neves, Patricia S.; Da Silva, Francisco A.
2008-01-01
An experimental work on controller tuning for chemical engineering undergraduate students is proposed using a small heat exchange unit. Based upon process reaction curves in open-loop configuration, system gain and time constant are determined for first order model with time delay with excellent accuracy. Afterwards students calculate PID…
School-Based Management and Arts Education: Lessons from Chicago
ERIC Educational Resources Information Center
Fitzpatrick, Kate R.
2012-01-01
School-based management, or local school control, is an organizational school reform effort aimed at decentralizing school decision-making that has become prevalent in districts throughout the United States. Using the groundbreaking Chicago system of local school control as an exemplar, this article outlines the implications of such reform efforts…
Hierarchical control of motor units in voluntary contractions.
De Luca, Carlo J; Contessa, Paola
2012-01-01
For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The "firing rate spectrum" presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units-both characteristics being well suited for generating and sustaining force during the fight-or-flight response.
Laser-assisted chemical vapor deposition setup for fast synthesis of graphene patterns
NASA Astrophysics Data System (ADS)
Zhang, Chentao; Zhang, Jianhuan; Lin, Kun; Huang, Yuanqing
2017-05-01
An automatic setup based on the laser-assisted chemical vapor deposition method has been developed for the rapid synthesis of graphene patterns. The key components of this setup include a laser beam control and focusing unit, a laser spot monitoring unit, and a vacuum and flow control unit. A laser beam with precision control of laser power is focused on the surface of a nickel foil substrate by the laser beam control and focusing unit for localized heating. A rapid heating and cooling process at the localized region is induced by the relative movement between the focalized laser spot and the nickel foil substrate, which causes the decomposing of gaseous hydrocarbon and the out-diffusing of excess carbon atoms to form graphene patterns on the laser scanning path. All the fabrication parameters that affect the quality and number of graphene layers, such as laser power, laser spot size, laser scanning speed, pressure of vacuum chamber, and flow rates of gases, can be precisely controlled and monitored during the preparation of graphene patterns. A simulation of temperature distribution was carried out via the finite element method, providing a scientific guidance for the regulation of temperature distribution during experiments. A multi-layer graphene ribbon with few defects was synthesized to verify its performance of the rapid growth of high-quality graphene patterns. Furthermore, this setup has potential applications in other laser-based graphene synthesis and processing.
The Green Tool represents infiltration-based stormwater control practices. It allows modelers to select a BMP type, channel shape and BMP unit dimensions, outflow control devices, and infiltration method. The program generates an HSPF-formatted FTABLE.
A novel body frame based approach to aerospacecraft attitude tracking.
Ma, Carlos; Chen, Michael Z Q; Lam, James; Cheung, Kie Chung
2017-09-01
In the common practice of designing an attitude tracker for an aerospacecraft, one transforms the Newton-Euler rotation equations to obtain the dynamic equations of some chosen inertial frame based attitude metrics, such as Euler angles and unit quaternions. A Lyapunov approach is then used to design a controller which ensures asymptotic convergence of the attitude to the desired orientation. Although this design methodology is pretty standard, it usually involves singularity-prone coordinate transformations which complicates the analysis process and controller design. A new, singularity free error feedback method is proposed in the paper to provide simple and intuitive stability analysis and controller synthesis. This new body frame based method utilizes the concept of Euleraxis and angles to generate the smallest error angles from a body frame perspective, without coordinate transformations. Global tracking convergence is illustrated with the use of a feedback linearizing PD tracker, a sliding mode controller, and a model reference adaptive controller. Experimental results are also obtained on a quadrotor platform with unknown system parameters and disturbances, using a boundary layer approximated sliding mode controller, a PIDD controller, and a unit sliding mode controller. Significant tracking quality is attained. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Cisneros, Carolina; Díaz-Campos, Rocío Magdalena; Marina, Núria; Melero, Carlos; Padilla, Alicia; Pascual, Silvia; Pinedo, Celia; Trisán, Andrea
2017-01-01
This paper, developed by consensus of staff physicians of accredited asthma units for the management of severe asthma, presents information on the process and requirements for already-existing asthma units to achieve official accreditation by the Spanish Society of Pneumology and Thoracic Surgery (SEPAR). Three levels of specialized asthma care have been established based on available resources, which include specialized units for highly complex asthma, specialized asthma units, and basic asthma units. Regardless of the level of accreditation obtained, the distinction of “excellence” could be granted when more requirements in the areas of provision of care, technical and human resources, training in asthma, and teaching and research activities were met at each level. The Spanish experience in the process of accreditation of specialized asthma units, particularly for the care of patients with difficult-to-control asthma, may be applicable to other health care settings. PMID:28533690
Improving Legacy Aircraft Systems Through Condition-Based Maintenance: An H-60 Case Study
2014-09-01
level functions. These decompositions are equivalent to a detailed design effort in systems engineering. NAMPSOPs have a common architectural structure...Assembly Power Available Spindle Cables No.1 Engine Load Demand Spindle Control Cables Engine Pneumatic Starters Auxiliary Power Unit IRCM FLIR Mission...Analysis Fuel System Main Rotor Head Main Module Main Gear Box Radiator Engine Output Shaft Auxiliary Power Unit Flight Control Cables Tail Landing
Li, Na; Yang, Qiao; Liu, Xing; Huang, Xuankai; Zhang, Haiyan; Wang, Chengxin
2017-12-06
Three-dimensional (3D) microstructured building units have replaced layer-to-layer stacked designs in transparent graphene films to fully exploit the advantages of two-dimensional graphene. However, it is still challenging to precisely control the size and microstructures of these building blocks to develop multifunctional graphene-based materials that satisfy the performance requirements of diverse applications. In this study, we propose a controllable method to regulate the microstructures of building units to form structures ranging from opened bubbles and cubes, while the size decreased from 20 to 3 μm, via an in situ template-modulating technology. NaCl was used as either a liquid or solid template by changing the dc bias. The reduced size and dense arrangement of the building units not only provide an improved mass loading for the transparent films but also build multiple pathways for fast ion/electron transmission, enhancing their promise for various practical applications. Generally, we provide a convenient protocol for finely regulating the microstructure and size of these building units, resulting in multifunctional films with a controllable transmittance, which enables the use of these graphene-based architectures as transparent electrodes in various applications and extends the family of multifunctional materials that will present new possibilities for electronics and other devices.
Microprocessor-based interface for oceanography
NASA Technical Reports Server (NTRS)
Hansen, G. R.
1979-01-01
Ocean floor imaging system incorporates five identical microprocessor-based interface units each assigned to specific sonar instrument to simplify system. Central control module based on same microprocessor eliminates need for custom tailoring hardware interfaces for each instrument.
Low-reflection beam refractions by ultrathin Huygens metasurface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jia, Sheng Li; State Key Laboratory of Millimeter Waves, School of Information Science and Engineering, Southeast University, Nanjing 210096; Synergetic Innovation Center of Wireless Communication Technology, Southeast University, Nanjing 210096
2015-06-15
We propose a Huygens source unit cell to develop an ultrathin low-reflection metasurface, which could provide extreme controls of phases of the transmitted waves. Both electric and magnetic currents are supported by the proposed unit cell, thus leading to highly efficient and full controls of phases. The coupling between electric and magnetic responses is negligible, which will significantly reduce the difficulty of design. Since the unit cell of metasurface is printed on two bonded boards, the fabrication process is simplified and the thickness of metasurface is reduced. Based on the proposed unit cell, a beam-refracting metasurface with low-reflection is designedmore » and manufactured. Both near-field and far-field characteristics of the beam-refracting metasurface are investigated by simulations and measurements, which indicate that the proposed Huygens metasurface performs well in controlling electromagnetic waves.« less
System for fracturing an underground geologic formation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, Jonathan L.; Tappan, Bryce C.; Seitz, Gerald J.
2017-03-14
An explosive system for fracturing an underground geologic formation adjacent to a wellbore can comprise a plurality of explosive units comprising an explosive material contained within the casing, and detonation control modules electrically coupled to the plurality of explosive units and configured to cause a power pulse to be transmitted to at least one detonator of at least one of the plurality of explosive units for detonation of the explosive material. The explosive units are configured to be positioned within a wellbore in spaced apart positions relative to one another along a string with the detonation control modules positioned adjacentmore » to the plurality of explosive units in the wellbore, such that the axial positions of the explosive units relative to the wellbore are at least partially based on geologic properties of the geologic formation adjacent the wellbore.« less
Retrofit concept for small safety related stationary machines
NASA Astrophysics Data System (ADS)
Epple, S.; Jalba, C. K.; Muminovic, A.; Jung, R.
2017-05-01
More and more old machines have the problem that their control electronics’ lifecycle comes to its intended end of life, whilst the mechanics itself and process capability is still in very good condition. This article shows an example of a reactive ion etcher originally built in 1988, which was refitted with a new control concept. The original control unit was repaired several times based on manufacturer’s obsolescence management. At start of the retrofit project the integrated circuits were no longer available for further repair of the original control unit. Safety, repeatability and stability of the process were greatly improved.
Tian, Zhen; Yuan, Jingqi; Xu, Liang; Zhang, Xiang; Wang, Jingcheng
2018-05-25
As higher requirements are proposed for the load regulation and efficiency enhancement, the control performance of boiler-turbine systems has become much more important. In this paper, a novel robust control approach is proposed to improve the coordinated control performance for subcritical boiler-turbine units. To capture the key features of the boiler-turbine system, a nonlinear control-oriented model is established and validated with the history operation data of a 300 MW unit. To achieve system linearization and decoupling, an adaptive feedback linearization strategy is proposed, which could asymptotically eliminate the linearization error caused by the model uncertainties. Based on the linearized boiler-turbine system, a second-order sliding mode controller is designed with the super-twisting algorithm. Moreover, the closed-loop system is proved robustly stable with respect to uncertainties and disturbances. Simulation results are presented to illustrate the effectiveness of the proposed control scheme, which achieves excellent tracking performance, strong robustness and chattering reduction. Copyright © 2018. Published by Elsevier Ltd.
Ba, Hengxing; Wu, Lang; Liu, Zongyue; Li, Chunyi
2016-01-01
Tandem repeat units are only detected in the left domain of the mitochondrial DNA control region in sika deer. Previous studies showed that Japanese sika deer have more tandem repeat units than its cousins from the Asian continent and Taiwan, which often have only three repeat units. To determine the origin and evolution of these additional repeat units in Japanese sika deer, we obtained the sequence of repeat units from an expanded dataset of the control region from all sika deer lineages. The functional constraint is inferred to act on the first repeat unit because this repeat has the least sequence divergence in comparison to the other units. Based on slipped-strand mispairing mechanisms, the illegitimate elongation model could account for the addition or deletion of these additional repeat units in the Japanese sika deer population. We also report that these additional repeat units could be occurring in the internal positions of tandem repeat regions, possibly via coupling with a homogenization mechanism within and among these lineages. Moreover, the increased number of repeat units in the Japanese sika deer population could reflect a balance between mutation and selection, as well as genetic drift.
A high-speed, large-capacity, 'jukebox' optical disk system
NASA Technical Reports Server (NTRS)
Ammon, G. J.; Calabria, J. A.; Thomas, D. T.
1985-01-01
Two optical disk 'jukebox' mass storage systems which provide access to any data in a store of 10 to the 13th bits (1250G bytes) within six seconds have been developed. The optical disk jukebox system is divided into two units, including a hardware/software controller and a disk drive. The controller provides flexibility and adaptability, through a ROM-based microcode-driven data processor and a ROM-based software-driven control processor. The cartridge storage module contains 125 optical disks housed in protective cartridges. Attention is given to a conceptual view of the disk drive unit, the NASA optical disk system, the NASA database management system configuration, the NASA optical disk system interface, and an open systems interconnect reference model.
Performance-based maintenance of gas turbines for reliable control of degraded power systems
NASA Astrophysics Data System (ADS)
Mo, Huadong; Sansavini, Giovanni; Xie, Min
2018-03-01
Maintenance actions are necessary for ensuring proper operations of control systems under component degradation. However, current condition-based maintenance (CBM) models based on component health indices are not suitable for degraded control systems. Indeed, failures of control systems are only determined by the controller outputs, and the feedback mechanism compensates the control performance loss caused by the component deterioration. Thus, control systems may still operate normally even if the component health indices exceed failure thresholds. This work investigates the CBM model of control systems and employs the reduced control performance as a direct degradation measure for deciding maintenance activities. The reduced control performance depends on the underlying component degradation modelled as a Wiener process and the feedback mechanism. To this aim, the controller features are quantified by developing a dynamic and stochastic control block diagram-based simulation model, consisting of the degraded components and the control mechanism. At each inspection, the system receives a maintenance action if the control performance deterioration exceeds its preventive-maintenance or failure thresholds. Inspired by realistic cases, the component degradation model considers random start time and unit-to-unit variability. The cost analysis of maintenance model is conducted via Monte Carlo simulation. Optimal maintenance strategies are investigated to minimize the expected maintenance costs, which is a direct consequence of the control performance. The proposed framework is able to design preventive maintenance actions on a gas power plant, to ensuring required load frequency control performance against a sudden load increase. The optimization results identify the trade-off between system downtime and maintenance costs as a function of preventive maintenance thresholds and inspection frequency. Finally, the control performance-based maintenance model can reduce maintenance costs as compared to CBM and pre-scheduled maintenance.
Device and method to enhance availability of cluster-based processing systems
NASA Technical Reports Server (NTRS)
Lupia, David J. (Inventor); Ramos, Jeremy (Inventor); Samson, Jr., John R. (Inventor)
2010-01-01
An electronic computing device including at least one processing unit that implements a specific fault signal upon experiencing an associated fault, a control unit that generates a specific recovery signal upon receiving the fault signal from the at least one processing unit, and at least one input memory unit. The recovery signal initiates specific recovery processes in the at least one processing unit. The input memory buffers input data signals input to the at least one processing unit that experienced the fault during the recovery period.
UNIX helps integrate control packages for combined cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forbes, H.W.
1994-05-01
This article describes the use of integrated UNIX based control systems in a combined-cycle power plant. The topics of the article include equipment configuration, control domains and functions for the gas turbine, steam turbine, balance of plant, unit-coordination, and plant master control, device gateway functions, and data-acquisition environment.
A Wireless Platform for Energy Efficient Building Control Retrofits
2012-08-01
University of Illinois at Urbana Champaign UTRC United Technologies Research Center VFD variable frequency drive WSN wireless sensor network ...demonstration area. .............................................................. 16 Table 4. Cost model for wireless sensor network ...buildings with MPC-based whole-building optimal control and (2) reduction in first costs achievable with a wireless sensor network (WSN)-based
Hierarchical control of motor units in voluntary contractions
Contessa, Paola
2012-01-01
For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The “firing rate spectrum” presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units—both characteristics being well suited for generating and sustaining force during the fight-or-flight response. PMID:21975447
[An automatic system controlled by microcontroller for carotid sinus perfusion].
Yi, X L; Wang, M Y; Fan, Z Z; He, R R
2001-08-01
To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block.
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-11-08
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.
Economic Evidence for U.S. Asthma Self-Management Education and Home-Based Interventions
Hsu, Joy; Wilhelm, Natalie; Lewis, Lillianne; Herman, Elizabeth
2016-01-01
The health and economic burden of asthma in the United States is substantial. Asthma self-management education (AS-ME) and home-based interventions for asthma can improve asthma control and prevent asthma exacerbations, and interest in health care-public health collaboration regarding asthma is increasing. However, outpatient AS-ME and home-based asthma intervention programs are not widely available; economic sustainability is a common concern. Thus, we conducted a narrative review of existing literature regarding economic outcomes of outpatient AS-ME and home-based intervention programs for asthma in the United States. We identified 9 outpatient AS-ME programs and 17 home-based intervention programs with return on investment (ROI) data. Most programs were associated with a positive ROI; a few programs observed positive ROIs only among selected populations (e.g., higher health care utilization). Interpretation of existing data is limited by heterogeneous ROI calculations. Nevertheless, the literature suggests promise for sustainable opportunities to expand access to outpatient AS-ME and home-based asthma intervention programs in the United States. More definitive knowledge about how to maximize program benefit and sustainability could be gained through more controlled studies of specific populations and increased uniformity in economic assessments. PMID:27658535
GPU-based optimal control for RWM feedback in tokamaks
Clement, Mitchell; Hanson, Jeremy; Bialek, Jim; ...
2017-08-23
The design and implementation of a Graphics Processing Unit (GPU) based Resistive Wall Mode (RWM) controller to perform feedback control on the RWM using Linear Quadratic Gaussian (LQG) control is reported herein. Also, the control algorithm is based on a simplified DIII-D VALEN model. By using NVIDIA’s GPUDirect RDMA framework, the digitizer and output module are able to write and read directly to and from GPU memory, eliminating memory transfers between host and GPU. In conclusion, the system and algorithm was able to reduce plasma response excited by externally applied fields by 32% during development experiments.
GPU-based optimal control for RWM feedback in tokamaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clement, Mitchell; Hanson, Jeremy; Bialek, Jim
The design and implementation of a Graphics Processing Unit (GPU) based Resistive Wall Mode (RWM) controller to perform feedback control on the RWM using Linear Quadratic Gaussian (LQG) control is reported herein. Also, the control algorithm is based on a simplified DIII-D VALEN model. By using NVIDIA’s GPUDirect RDMA framework, the digitizer and output module are able to write and read directly to and from GPU memory, eliminating memory transfers between host and GPU. In conclusion, the system and algorithm was able to reduce plasma response excited by externally applied fields by 32% during development experiments.
Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment
Mantilla, Carlos B.; Seven, Yasin B.; Sieck, Gary C.
2014-01-01
Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation, but are also active in other non-ventilatory behaviors, including coughing, sneezing, vomiting, defecation and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely-distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. PMID:24746055
Nurse- vs nomogram-directed glucose control in a cardiovascular intensive care unit.
Chant, Clarence; Mustard, Mary; Thorpe, Kevin E; Friedrich, Jan O
2012-07-01
Paper-based nomograms are reasonably effective for achieving glycemic control but have low adherence and are less adaptive than nurses' judgment. To compare efficacy (glucose control) and safety (hypoglycemia) achieved by use of a paper nomogram versus nurses' judgment. Prospective, randomized, open-label, crossover trial in an intensive care unit in postoperative patients with glucose concentrations greater than 8 mmol/L. Consenting nurses with at least 1 year of experience were randomized to use either their judgment or a validated paper-based nomogram for glucose control. After completion of 2 study shifts, the nurses used the alternative method for the next 2 study shifts. Glucose target level and safety and efficacy boundaries were the same for both methods. The primary end point was area under glucose time curve per hour. Thirty-four nurses contributed 95 shifts of data (44 nomogram-directed, 51 nurse-directed). Adherence to the nomogram was higher in the nomogram group than hypothetical adherence in the nurse-directed group for correct adjustments in insulin infusion (70% vs 37%; P < .001) and glucose checks (58% vs 43%; P = .008). The primary end point did not differ between the 2 groups (mean, 9.0 mmol/L; SD, 3.5 vs mean, 8.3 mmol/L; SD, 2.1; P = .08). Glucose variability, amount of time patients were hypoglycemic or hyperglycemic, and number of glucose checks performed were similar in the 2 groups. In an intensive care unit where nurses generally accepted the need for tight glucose control, nurse-directed control was as effective and as safe as nomogram-based control.
Mjåland, Kristian
2015-08-01
Opiate maintenance treatment (OMT) is increasingly being offered in prisons throughout Europe. The benefits of OMT in prison have been found to be similar to those produced by OMT in community settings. However, prison-based OMT has been a controversial issue because of fear of the diversion of OMT medications and the development of black markets for prescription drugs such as buprenorphine and methadone. Prison-based OMT thus involves a delicate balance between the considerations of control and treatment. This article reports on an ethnographic study of a prison-based OMT programme in a closed Norwegian prison. The data include field notes from eight months of participant observation in the prison as well as qualitative interviews with 23 prisoners and 12 prison staff. Midway through the fieldwork, the prison authorities established a separate unit for OMT-enrolled prisoners to reduce the widespread diversion of buprenorphine. This "natural experiment" is explored in the analysis. The prison-based OMT programme was characterised by strict and repressive control to prevent the diversion of buprenorphine, and the control became even stricter after the establishment of the OMT unit. However, the diversion of buprenorphine increased rather than decreased after the establishment of the OMT unit. To understand this "paradox of control", the article engages with theories of legitimacy, power and resistance. The excessive and repressive control was perceived as illegitimate and unfair by the majority of study participants. In various ways, many prisoners protested, confronted and subverted the OMT programme. The increase in buprenorphine diversion is interpreted as a form of collective resistance towards the perceived unfairness of the OMT programme. The article demonstrates that an unbalanced and control-dominated approach to prison-based OMT may have the opposite effect of what is intended. Copyright © 2015 The Author. Published by Elsevier B.V. All rights reserved.
Secure, Autonomous, Intelligent Controller for Integrating Distributed Sensor Webs
NASA Technical Reports Server (NTRS)
Ivancic, William D.
2007-01-01
This paper describes the infrastructure and protocols necessary to enable near-real-time commanding, access to space-based assets, and the secure interoperation between sensor webs owned and controlled by various entities. Select terrestrial and aeronautics-base sensor webs will be used to demonstrate time-critical interoperability between integrated, intelligent sensor webs both terrestrial and between terrestrial and space-based assets. For this work, a Secure, Autonomous, Intelligent Controller and knowledge generation unit is implemented using Virtual Mission Operation Center technology.
1976-11-01
Box 209, St. Louis, Missouri 63166. UNITED STATES ARMY AVIATION ENGINEERING FLIGHT ACTIVITY EDWARDS AIR FORCE BASE, CALIFORNIA 93523 81 9 18 0 8,L...ELEMENT. PROJECT. TASKAR EA A WORK UNIT "UMBERS US ARMY AVIATION ENGINEERING FLIGHT ACTIV IU EDWARDS AIR FORCE BASE. CALIFORNIA 93523 68-T-UA022-0-68-EC...It. CONTROLLI~NG OFFICE NAME AND ADDRESS 12. REPORT DATE US ARMY AVIATION ENGINEERING FLIGHT ACTIVITY NOVEMBER 1976 EDWARDS AIR FORCE BASE
Motor Controller System For Large Dynamic Range of Motor Operation
NASA Technical Reports Server (NTRS)
Howard, David E. (Inventor); Alhorn, Dean C. (Inventor); Smith, Dennis A. (Inventor); Dutton, Kenneth R. (Inventor); Paulson, Mitchell Scott (Inventor)
2006-01-01
A motor controller system uses a rotary sensor with a plurality of signal conditioning units, coupled to the rotary sensor. Each of these units, which is associated with a particular range of motor output shaft rotation rates, generate a feedback signal indicative of the position of the motor s output shaft. A controller (i) converts a selected motor output shaft rotation rate to a corresponding incremental amount of rotational movement for a selected fixed time period, (ii) selects, at periodic completions of the selected fixed time period, the feedback signal from one of the signal conditioning units for which the particular range of motor output shaft rotation rates associated therewith encompasses the selected motor output shaft rotation rate, and (iii) generates a motor drive signal based on a difference between the incremental amount of rotational movement and the feedback signal from the selected one of the signal conditioning Units.
NASA Astrophysics Data System (ADS)
Terrazas-Arellanes, Fatima E.; Gallard M., Alejandro J.; Strycker, Lisa A.; Walden, Emily D.
2018-03-01
The purpose of this study was to document the design, classroom implementation, and effectiveness of interactive online units to enhance science learning over 3 years among students with learning disabilities, English learners, and general education students. Results of a randomised controlled trial with 2,303 middle school students and 71 teachers across 13 schools in two states indicated that online units effectively deepened science knowledge across all three student groups. Comparing all treatment and control students on pretest-to-posttest improvement on standards-based content-specific assessments, there were statistically significant mean differences (17% improvement treatment vs. 6% control; p < .001); no significant interactions were found between treatment condition and learning disability or English learner status, indicating that these two groups performed similarly to their peers; students with learning disabilities had significantly lower assessment scores overall. Teachers and students were moderately satisfied with the units.
Reliability modelling and analysis of a multi-state element based on a dynamic Bayesian network
NASA Astrophysics Data System (ADS)
Li, Zhiqiang; Xu, Tingxue; Gu, Junyuan; Dong, Qi; Fu, Linyu
2018-04-01
This paper presents a quantitative reliability modelling and analysis method for multi-state elements based on a combination of the Markov process and a dynamic Bayesian network (DBN), taking perfect repair, imperfect repair and condition-based maintenance (CBM) into consideration. The Markov models of elements without repair and under CBM are established, and an absorbing set is introduced to determine the reliability of the repairable element. According to the state-transition relations between the states determined by the Markov process, a DBN model is built. In addition, its parameters for series and parallel systems, namely, conditional probability tables, can be calculated by referring to the conditional degradation probabilities. Finally, the power of a control unit in a failure model is used as an example. A dynamic fault tree (DFT) is translated into a Bayesian network model, and subsequently extended to a DBN. The results show the state probabilities of an element and the system without repair, with perfect and imperfect repair, and under CBM, with an absorbing set plotted by differential equations and verified. Through referring forward, the reliability value of the control unit is determined in different kinds of modes. Finally, weak nodes are noted in the control unit.
Flight Model of the `Flying Laptop' OBC and Reconfiguration Unit
NASA Astrophysics Data System (ADS)
Eickhoff, Jens; Stratton, Sam; Butz, Pius; Cook, Barry; Walker, Paul; Uryu, Alexander; Lengowski, Michael; Roser, Hans-Peter
2012-08-01
As already published in papers at the DASIA conferences 2010 in Budapest [1] and 2011 in Malta [2], the University of Stuttgart, Germany, is developing an advanced 3-axis stabilized small satellite applying industry standards for command/control techniques, onboard software design and onboard computer components. The satellite has a launch mass of approx. 120kg. One of the main challenges was the development of an ultra compact and performing onboard computer (OBC), which was intended to support an RTEMS operating system, a PUS standard based onboard software (OBSW) and CCSDS standard based ground/space communication. The developed architecture is based on 4 main elements (see [1, 2] and Figure 3) which are developed in cooperation with industrial partners:• the OBC core board based on the LEON3 FT architecture,• an I/O Board for all OBC digital interfaces to S/C equipment,• a CCSDS TC/TM decoder/encoder board,• reconfiguration unit being embedded in the satellite power control and distribution unit PCDU.In the meantime the EM / Breadboard units of the computer have been tested intensively including first HW/SW integration tests in a Satellite Testbench (see Figure 2). The FM HW elements from the co-authoring suppliers are under assembly in Stuttgart.
NASA Astrophysics Data System (ADS)
Melinda, Intan Dewi; Jauhari, Wakhid Ahmad
2018-02-01
Spare part procurement is a complex issue and requires an accurate analysis. Stock outs of spare part can leads a great impact on production. Therefore, it is necessary to design the inventory control of spare parts that guarantee the availability of spare parts needed for supporting the maintenance activity. This paper studies the inventory policy for sewing machine spare part using hazard function to approximate the demand. Hazard function is the indicator of the effect of ageing on the reliability of the system. It quantifies the risk of failure as the age of the system increases. We use a continuous review policy based on Hadley Within Approach to calculate the optimum inventory level for critical spare parts. There are four spare parts categorized as critical spare parts, which are needle plate, feed dog, rotary and binder attachment. The optimal ordering quantity for needle plate, feed, rotary and binder attachment are 5 units, 17 units, 5 units, and 9 units, respectively and the reorder point are 2 units, 1 unit, 2 units and 1 unit, respectively. Finally, the service level achieved by the proposed policy is in a range of 95.91%-97.93%, which indicates that the inventory level of spare parts can be used to support the required parts in the maintenance activity.
Odeen, Magnus; Ihlebæk, Camilla; Indahl, Aage; Wormgoor, Marjon E A; Lie, Stein A; Eriksen, Hege R
2013-06-01
To evaluate whether information and reassurance about low back pain (LBP) given to employees at the workplace could reduce sick leave. A Cluster randomized controlled trial with 135 work units of about 3,500 public sector employees in two Norwegian municipalities, randomized into two intervention groups; Education and peer support (EPS) (n = 45 units), education and "peer support and access to an outpatient clinic" (EPSOC) (n = 48 units), and a control group (n = 42 units). Both interventions consisted of educational meetings based on a "non-injury model" and a "peer adviser" appointed by colleagues. Employees in the EPSOC group had access to an outpatient clinic for medical examination and further education. The control group received no intervention. The main outcome was sick leave based on municipal records. Secondary outcomes were self-reported pain, pain related fear of movement, coping, and beliefs about LBP from survey data of 1,746 employees (response rate about 50 %). EPS reduced sick leave by 7 % and EPSOC reduced sick leave by 4 % during the intervention year, while sick leave in the control group was increased by 7 % during the same period. Overall, Rate Ratios (RR) were statistically significant for EPSOC (RR = .84 (C.I = 0.71-.99) but not EPS (RR = .92 (C.I = 0.78-1.09)) in a mixed Poisson regression analysis. Faulty beliefs about LBP were reduced in both intervention groups. Educational meetings, combined with peer support and access to an outpatient clinic, were effective in reducing sick leave in public sector employees.
Schnipper, Jeffrey Lawrence; Messler, Jordan; Ramos, Pedro; Kulasa, Kristen; Nolan, Ann; Rogers, Kendall
2014-01-01
Background: Insulin is a top source of adverse drug events in the hospital, and glycemic control is a focus of improvement efforts across the country. Yet, the majority of hospitals have no data to gauge their performance on glycemic control, hypoglycemia rates, or hypoglycemic management. Current tools to outsource glucometrics reports are limited in availability or function. Methods: Society of Hospital Medicine (SHM) faculty designed and implemented a web-based data and reporting center that calculates glucometrics on blood glucose data files securely uploaded by users. Unit labels, care type (critical care, non–critical care), and unit type (eg, medical, surgical, mixed, pediatrics) are defined on upload allowing for robust, flexible reporting. Reports for any date range, care type, unit type, or any combination of units are available on demand for review or downloading into a variety of file formats. Four reports with supporting graphics depict glycemic control, hypoglycemia, and hypoglycemia management by patient day or patient stay. Benchmarking and performance ranking reports are generated periodically for all hospitals in the database. Results: In all, 76 hospitals have uploaded at least 12 months of data for non–critical care areas and 67 sites have uploaded critical care data. Critical care benchmarking reveals wide variability in performance. Some hospitals achieve top quartile performance in both glycemic control and hypoglycemia parameters. Conclusions: This new web-based glucometrics data and reporting tool allows hospitals to track their performance with a flexible reporting system, and provides them with external benchmarking. Tools like this help to establish standardized glucometrics and performance standards. PMID:24876426
Maynard, Greg; Schnipper, Jeffrey Lawrence; Messler, Jordan; Ramos, Pedro; Kulasa, Kristen; Nolan, Ann; Rogers, Kendall
2014-07-01
Insulin is a top source of adverse drug events in the hospital, and glycemic control is a focus of improvement efforts across the country. Yet, the majority of hospitals have no data to gauge their performance on glycemic control, hypoglycemia rates, or hypoglycemic management. Current tools to outsource glucometrics reports are limited in availability or function. Society of Hospital Medicine (SHM) faculty designed and implemented a web-based data and reporting center that calculates glucometrics on blood glucose data files securely uploaded by users. Unit labels, care type (critical care, non-critical care), and unit type (eg, medical, surgical, mixed, pediatrics) are defined on upload allowing for robust, flexible reporting. Reports for any date range, care type, unit type, or any combination of units are available on demand for review or downloading into a variety of file formats. Four reports with supporting graphics depict glycemic control, hypoglycemia, and hypoglycemia management by patient day or patient stay. Benchmarking and performance ranking reports are generated periodically for all hospitals in the database. In all, 76 hospitals have uploaded at least 12 months of data for non-critical care areas and 67 sites have uploaded critical care data. Critical care benchmarking reveals wide variability in performance. Some hospitals achieve top quartile performance in both glycemic control and hypoglycemia parameters. This new web-based glucometrics data and reporting tool allows hospitals to track their performance with a flexible reporting system, and provides them with external benchmarking. Tools like this help to establish standardized glucometrics and performance standards. © 2014 Diabetes Technology Society.
A Study on Aircraft Engine Control Systems for Integrated Flight and Propulsion Control
NASA Astrophysics Data System (ADS)
Yamane, Hideaki; Matsunaga, Yasushi; Kusakawa, Takeshi; Yasui, Hisako
The Integrated Flight and Propulsion Control (IFPC) for a highly maneuverable aircraft and a fighter-class engine with pitch/yaw thrust vectoring is described. Of the two IFPC functions the aircraft maneuver control utilizes the thrust vectoring based on aerodynamic control surfaces/thrust vectoring control allocation specified by the Integrated Control Unit (ICU) of a FADEC (Full Authority Digital Electronic Control) system. On the other hand in the Performance Seeking Control (PSC) the ICU identifies engine's various characteristic changes, optimizes manipulated variables and finally adjusts engine control parameters in cooperation with the Engine Control Unit (ECU). It is shown by hardware-in-the-loop simulation that the thrust vectoring can enhance aircraft maneuverability/agility and that the PSC can improve engine performance parameters such as SFC (specific fuel consumption), thrust and gas temperature.
Nonlinear adaptive control of grid-connected three-phase inverters for renewable energy applications
NASA Astrophysics Data System (ADS)
Mahdian-Dehkordi, N.; Namvar, M.; Karimi, H.; Piya, P.; Karimi-Ghartemani, M.
2017-01-01
Distributed generation (DG) units are often interfaced to the main grid using power electronic converters including voltage-source converters (VSCs). A VSC offers dc/ac power conversion, high controllability, and fast dynamic response. Because of nonlinearities, uncertainties, and system parameters' changes involved in the nature of a grid-connected renewable DG system, conventional linear control methods cannot completely and efficiently address all control objectives. In this paper, a nonlinear adaptive control scheme based on adaptive backstepping strategy is presented to control the operation of a grid-connected renewable DG unit. As compared to the popular vector control technique, the proposed controller offers smoother transient responses, and lower level of current distortions. The Lyapunov approach is used to establish global asymptotic stability of the proposed control system. Linearisation technique is employed to develop guidelines for parameters tuning of the controller. Extensive time-domain digital simulations are performed and presented to verify the performance of the proposed controller when employed in a VSC to control the operation of a two-stage DG unit and also that of a single-stage solar photovoltaic system. Desirable and superior performance of the proposed controller is observed.
Plant growth chamber based on space proven controlled environment technology
NASA Astrophysics Data System (ADS)
Ignatius, Ronald W.; Ignatius, Matt H.; Imberti, Henry J.
1997-01-01
Quantum Devices, Inc., in conjunction with Percival Scientific, Inc., and the Wisconsin Center for Space Automation and Robotics (WCSAR) have developed a controlled environment plant growth chamber for terrestrial agricultural and scientific applications. This chamber incorporates controlled environment technology used in the WCSAR ASTROCULTURE™ flight unit for conducting plant research on the Space Shuttle. The new chamber, termed CERES 2010, features air humidity, temperature, and carbon dioxide control, an atmospheric contaminant removal unit, an LED lighting system, and a water and nutrient delivery system. The advanced environment control technology used in this chamber will increase the reliability and repeatability of environmental physiology data derived from plant experiments conducted in this chamber.
73. View of launch control center towards the blast door ...
73. View of launch control center towards the blast door and west, deputy commander standing in front of modular bed storage unit - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
Ławryńczuk, Maciej
2017-03-01
This paper details development of a Model Predictive Control (MPC) algorithm for a boiler-turbine unit, which is a nonlinear multiple-input multiple-output process. The control objective is to follow set-point changes imposed on two state (output) variables and to satisfy constraints imposed on three inputs and one output. In order to obtain a computationally efficient control scheme, the state-space model is successively linearised on-line for the current operating point and used for prediction. In consequence, the future control policy is easily calculated from a quadratic optimisation problem. For state estimation the extended Kalman filter is used. It is demonstrated that the MPC strategy based on constant linear models does not work satisfactorily for the boiler-turbine unit whereas the discussed algorithm with on-line successive model linearisation gives practically the same trajectories as the truly nonlinear MPC controller with nonlinear optimisation repeated at each sampling instant. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-05-01
This operable unit consists of Sites 41 and 74. The remedial actions are designed to prevent future potential exposure by implementing institutional controls. These controls include: (1) designate the sites as `restricted` or `limited use` areas, within the base master plan; (2) prohibit the installation of potable water supply wells within the vicinity of the sites: and (3) implement a groundwater, surface water and sediment monitoring program.
Thomas, Bruce W; Berg-Copas, Gina M; Vasquez, Donald G; Jackson, Brandy L; Wetta-Hall, Ruth
2009-05-01
Hand washing is considered the single most important nosocomial infection-control strategy, yet compliance rarely meets levels recommended by infection control authorities. To determine whether placement of hand hygiene foam dispensers in more conspicuous positions and closer proximity to patients would increase use of infection control agents as measured by volume of product used. Further, to ascertain the influence of dispenser placement vs the number of dispensers available on usage by volume. This prospective, observational study conducted in an intensive care unit was composed of three observation periods. A control period with standard agent dispenser location (8 dispensers) was followed by two experimental periods: (1) "conspicuous and immediate proximity to patient" placement (16 dispensers) and (2) standard locations with a dramatic increase in the number of dispensers (36 dispensers). Volume of use for alcohol-based hand hygiene agent during the three observation periods revealed a statistically significant increase in daily consumption after conspicuous and proximate positioning of dispensers (P<.001). However, increasing the number of dispensers did not increase agent use (P=.196). More conspicuous placement of dispensers containing alcohol-based hand hygiene agent (ie, immediate proximity to patients) resulted in statistically and clinically significant increases in product usage. An increase in the number of dispensers did not increase usage. The impact of dispenser positioning on usage by volume for these highly effective products should be considered when planning and implementing intensive care unit infection-control policies.
2009-02-27
exchanged by means of line-of-sight sensors that experience periodic communication dropouts due to agent motion. Variation in network topology in...respiratory, and cardiovascular function by man- ual control based on the clinician’s experience and intuition. Open-loop control by clinical personnel can be...to ap- pear. [29] W. M. Haddad and J. M. Bailey, "Closed-Loop Control for Intensive Care Unit Seda- tion," Best Prac. Res. Clinical Anaesthesiology
24 CFR 960.707 - Pet ownership.
Code of Federal Regulations, 2010 CFR
2010-04-01
... maintains each pet: (1) Responsibly; (2) In accordance with applicable State and local public health, animal control, and animal anti-cruelty laws and regulations; and (3) In accordance with the policies established... covered, or both; (2) Limitations on the number of animals in a unit, based on unit size; (3) Prohibitions...
76 FR 76151 - Notice of Submission for OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-06
... Evaluation Systems in the United States will contribute to the Department's work by providing research-based information to aid state and local efforts to plan and implement comprehensive teacher evaluation systems. The... United States. OMB Control Number: Pending. Agency Form Number(s): N/A. Frequency of Responses: Annually...
Wireless Augmented Reality Prototype (WARP)
NASA Technical Reports Server (NTRS)
Devereaux, A. S.
1999-01-01
Initiated in January, 1997, under NASA's Office of Life and Microgravity Sciences and Applications, the Wireless Augmented Reality Prototype (WARP) is a means to leverage recent advances in communications, displays, imaging sensors, biosensors, voice recognition and microelectronics to develop a hands-free, tetherless system capable of real-time personal display and control of computer system resources. Using WARP, an astronaut may efficiently operate and monitor any computer-controllable activity inside or outside the vehicle or station. The WARP concept is a lightweight, unobtrusive heads-up display with a wireless wearable control unit. Connectivity to the external system is achieved through a high-rate radio link from the WARP personal unit to a base station unit installed into any system PC. The radio link has been specially engineered to operate within the high- interference, high-multipath environment of a space shuttle or space station module. Through this virtual terminal, the astronaut will be able to view and manipulate imagery, text or video, using voice commands to control the terminal operations. WARP's hands-free access to computer-based instruction texts, diagrams and checklists replaces juggling manuals and clipboards, and tetherless computer system access allows free motion throughout a cabin while monitoring and operating equipment.
Conceptual design of the X-IFU Instrument Control Unit on board the ESA Athena mission
NASA Astrophysics Data System (ADS)
Corcione, L.; Ligori, S.; Capobianco, V.; Bonino, D.; Valenziano, L.; Guizzo, G. P.
2016-07-01
Athena is one of L-class missions selected in the ESA Cosmic Vision 2015-2025 program for the science theme of the Hot and Energetic Universe. The Athena model payload includes the X-ray Integral Field Unit (X-IFU), an advanced actively shielded X-ray microcalorimeter spectrometer for high spectral resolution imaging, utilizing cooled Transition Edge Sensors. This paper describes the preliminary architecture of Instrument Control Unit (ICU), which is aimed at operating all XIFU's subsystems, as well as at implementing the main functional interfaces of the instrument with the S/C control unit. The ICU functions include the TC/TM management with S/C, science data formatting and transmission to S/C Mass Memory, housekeeping data handling, time distribution for synchronous operations and the management of the X-IFU components (i.e. CryoCoolers, Filter Wheel, Detector Readout Electronics Event Processor, Power Distribution Unit). ICU functions baseline implementation for the phase-A study foresees the usage of standard and Space-qualified components from the heritage of past and current space missions (e.g. Gaia, Euclid), which currently encompasses Leon2/Leon3 based CPU board and standard Space-qualified interfaces for the exchange commands and data between ICU and X-IFU subsystems. Alternative architecture, arranged around a powerful PowerPC-based CPU, is also briefly presented, with the aim of endowing the system with enhanced hardware resources and processing power capability, for the handling of control and science data processing tasks not defined yet at this stage of the mission study.
Chai, Shua J; Mattingly, Daniel C; Varma, Jay K
2013-01-01
Tuberculosis causes >1.7 million deaths worldwide each year and is frequently transmitted in hospitals. Outbreaks of multidrug-resistant tuberculosis have led to illness and death among health care workers (HCWs) in many countries. Some countries, such as the United States, implemented occupational health policies that substantially reduced tuberculosis rates among HCWs. Inadequate tuberculosis infection control in China may contribute to its high burden of tuberculosis and multidrug-resistant tuberculosis, which are both the second highest worldwide. Occupational health policies in China for tuberculosis control can be strengthened. We reviewed the development and content of tuberculosis infection control policies in the United States and China. Sources included published academic literature, Chinese Ministry of Health policies, US government agency reports, legal databases, personal observations of hospitals, review of internet discussion sites, and discussions with HCWs and health care and law experts. In the United States, slow acceptance of the tuberculosis problem in HCWs resulted in decades of inaction. Tuberculosis infection control policies, based mostly on expert opinion, were implemented only after tuberculosis resurged in the 1980s. Effective evidence-based policies were developed only after multiple cycles of policy implementation, evaluation and revision. These policies have now substantially reduced occupational tuberculosis. In China, tuberculosis has not been formally recognized as an occupational disease, and data regarding the burden in HCWs are sparse. Vagueness of current labour laws and suboptimal alignment of infection control authority and expertise result in varied and sometimes absent protection of HCWs against tuberculosis. Formal evaluations of occupational tuberculosis policies have not been reported. By collecting data on its current HCW tuberculosis burden and infection control practices, refining policies, continually evaluating its policies based on accumulated evidence and rapidly identifying unsuspected tuberculosis cases, China can develop a more comprehensive strategy to ensure the health of HCWs and reduce transmission of tuberculosis and multidrug-resistant tuberculosis.
Modeling and control of fuel cell based distributed generation systems
NASA Astrophysics Data System (ADS)
Jung, Jin Woo
This dissertation presents circuit models and control algorithms of fuel cell based distributed generation systems (DGS) for two DGS topologies. In the first topology, each DGS unit utilizes a battery in parallel to the fuel cell in a standalone AC power plant and a grid-interconnection. In the second topology, a Z-source converter, which employs both the L and C passive components and shoot-through zero vectors instead of the conventional DC/DC boost power converter in order to step up the DC-link voltage, is adopted for a standalone AC power supply. In Topology 1, two applications are studied: a standalone power generation (Single DGS Unit and Two DGS Units) and a grid-interconnection. First, dynamic model of the fuel cell is given based on electrochemical process. Second, two full-bridge DC to DC converters are adopted and their controllers are designed: an unidirectional full-bridge DC to DC boost converter for the fuel cell and a bidirectional full-bridge DC to DC buck/boost converter for the battery. Third, for a three-phase DC to AC inverter without or with a Delta/Y transformer, a discrete-time state space circuit model is given and two discrete-time feedback controllers are designed: voltage controller in the outer loop and current controller in the inner loop. And last, for load sharing of two DGS units and power flow control of two DGS units or the DGS connected to the grid, real and reactive power controllers are proposed. Particularly, for the grid-connected DGS application, a synchronization issue between an islanding mode and a paralleling mode to the grid is investigated, and two case studies are performed. To demonstrate the proposed circuit models and control strategies, simulation test-beds using Matlab/Simulink are constructed for each configuration of the fuel cell based DGS with a three-phase AC 120 V (L-N)/60 Hz/50 kVA and various simulation results are presented. In Topology 2, this dissertation presents system modeling, modified space vector PWM implementation (MSVPWM) and design of a closed-loop controller of the Z-source converter which utilizes L and C components and shoot-through zero vectors for the standalone AC power generation. The fuel cell system is modeled by an electrical R-C circuit in order to include slow dynamics of the fuel cells and a voltage-current characteristic of a cell is also considered. A discrete-time state space model is derived to implement digital control and a space vector pulse-width modulation (SVPWM) technique is modified to realize the shoot-through zero vectors that boost the DC-link voltage. Also, three discrete-time feedback controllers are designed: a discrete-time optimal voltage controller, a discrete-time sliding mode current controller, and a discrete-time PI DC-link voltage controller. Furthermore, an asymptotic observer is used to reduce the number of sensors and enhance the reliability of the system. To demonstrate the analyzed circuit model and proposed control strategy, various simulation results using Matlab/Simulink are presented under both light/heavy loads and linear/nonlinear loads for a three-phase AC 208 V (L-L)/60 Hz/10 kVA.
Valve Health Monitoring System Utilizing Smart Instrumentation
NASA Technical Reports Server (NTRS)
Jensen, Scott L.; Drouant, George J.
2006-01-01
The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station
Valve health monitoring system utilizing smart instrumentation
NASA Astrophysics Data System (ADS)
Jensen, Scott L.; Drouant, George J.
2006-05-01
The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are: cryogenic cycles, total cycles, inlet temperature, outlet temperature, body temperature, torsional strain, linear bonnet strain, preload position, total travel, and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commissions requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates related data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 Enclosures are used to house the base-station.
75 FR 76935 - Revisions to the United States Munitions List
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-10
... USML. Separately, the use of ``specially designed'' as a control criterion for the other ``parts... significantly different. Many of the ITAR's USML controls are based on subjective or design- intent criteria... categories contain a non-specific catch-all control over every ``part'' or ``component'' that was...
Perceptions of Control Facilitate Reading Engagement
ERIC Educational Resources Information Center
Vieira, Edward T., Jr.; Grantham, Susan
2011-01-01
This study examined how global locus of control influences children's reading engagement or reading involvement and interest in stories. It is based on locus of control, interest, and dual information processing theories. One hundred and seventy students from schools in the northeastern United States, ages 9 to 12, participated. They completed a…
Electromechanical Devices and Controllers. Electronics Module 10. Instructor's Guide.
ERIC Educational Resources Information Center
Carter, Ed
This module is the tenth of 10 modules in the competency-based electronics series. Introductory materials include a listing of competencies addressed in the module, a parts/equipment list, and a cross-reference table of instructional materials. Six instructional units cover: electromechanical control devices; programmable logic controllers (PLC);…
78 FR 62500 - Schedules of Controlled Substances: Placement of Perampanel into Schedule III
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... of the Controlled Substances Act (CSA). This proposed action is based on a recommendation from the... (manufacture, distribute, dispense, import, export, engage in research, conduct instructional activities, and..., scientific, research, and industrial needs of the United States. Controlled substances have the potential for...
Public Health Control Measures in Response to Global Pandemics and Drug Resistance.
Price, Polly J
2015-01-01
These teaching materials provide problem-based exercises exploring the specific powers of governments to implement control measures in response to communicable disease. Topics include global pandemic disease and, in the United States, legal issues in tuberculosis control. © 2015 American Society of Law, Medicine & Ethics, Inc.
Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment.
Mantilla, Carlos B; Seven, Yasin B; Sieck, Gary C
2014-01-01
Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation but are also active in other nonventilatory behaviors, including coughing, sneezing, vomiting, defecation, and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly, properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors, whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing, or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. © 2014 Elsevier B.V. All rights reserved.
Evaluation of Volatilization Potential for Legacy Chlordane in Military Housing Area Soils
2011-10-01
chlordane, to control termites around base housing until it was banned in 1988. As bases are closed, contracted, or realigned, soil issues associated...for termite control around or under building foundations. This pesticide was used to treat many U.S. military housing units either before or after...to 1988, chlordane’s only approved use was for underground application to control termites in buildings. In 1988, all uses of chlordane in the
Pupil Control Ideology: Comparative Perspectives--United States and Canada.
ERIC Educational Resources Information Center
Hamalian, A.
1979-01-01
This study explores the relationship between the Pupil Control Ideology Scale (PCI) and the sex of the teacher, level of teaching (preschool, elementary, secondary), as well as level of school bureaucracy based on the Moeller scale. (Author/RTS)
NASA Astrophysics Data System (ADS)
Zhao, Yan; Yang, Zijiang; Gao, Song; Liu, Jinbiao
2018-02-01
Automatic generation control(AGC) is a key technology to maintain real time power generation and load balance, and to ensure the quality of power supply. Power grids require each power generation unit to have a satisfactory AGC performance, being specified in two detailed rules. The two rules provide a set of indices to measure the AGC performance of power generation unit. However, the commonly-used method to calculate these indices is based on particular data samples from AGC responses and will lead to incorrect results in practice. This paper proposes a new method to estimate the AGC performance indices via system identification techniques. In addition, a nonlinear regression model between performance indices and load command is built in order to predict the AGC performance indices. The effectiveness of the proposed method is validated through industrial case studies.
MSuPDA: A memory efficient algorithm for sequence alignment.
Khan, Mohammad Ibrahim; Kamal, Md Sarwar; Chowdhury, Linkon
2015-01-16
Space complexity is a million dollar question in DNA sequence alignments. In this regards, MSuPDA (Memory Saving under Pushdown Automata) can help to reduce the occupied spaces in computer memory. Our proposed process is that Anchor Seed (AS) will be selected from given data set of Nucleotides base pairs for local sequence alignment. Quick Splitting (QS) techniques will separate the Anchor Seed from all the DNA genome segments. Selected Anchor Seed will be placed to pushdown Automata's (PDA) input unit. Whole DNA genome segments will be placed into PDA's stack. Anchor Seed from input unit will be matched with the DNA genome segments from stack of PDA. Whatever matches, mismatches or Indel, of Nucleotides will be POP from the stack under the control of control unit of Pushdown Automata. During the POP operation on stack it will free the memory cell occupied by the Nucleotide base pair.
Design of a fault-tolerant reversible control unit in molecular quantum-dot cellular automata
NASA Astrophysics Data System (ADS)
Bahadori, Golnaz; Houshmand, Monireh; Zomorodi-Moghadam, Mariam
Quantum-dot cellular automata (QCA) is a promising emerging nanotechnology that has been attracting considerable attention due to its small feature size, ultra-low power consuming, and high clock frequency. Therefore, there have been many efforts to design computational units based on this technology. Despite these advantages of the QCA-based nanotechnologies, their implementation is susceptible to a high error rate. On the other hand, using the reversible computing leads to zero bit erasures and no energy dissipation. As the reversible computation does not lose information, the fault detection happens with a high probability. In this paper, first we propose a fault-tolerant control unit using reversible gates which improves on the previous design. The proposed design is then synthesized to the QCA technology and is simulated by the QCADesigner tool. Evaluation results indicate the performance of the proposed approach.
Childs, J E; Kaufmann, A F; Peters, C J; Ehrenberg, R L
1993-07-30
This report provides interim recommendations for prevention and control of hantavirus infections associated with rodents in the southwestern United States. It is based on principles of rodent and infection control and contains specific recommendations for reducing rodent shelter and food sources in and around the home, recommendations for eliminating rodents inside the home and preventing them from entering the home, precautions for preventing hantavirus infection while rodent-contaminated areas are being cleaned up, prevention measures for persons who have occupational exposure to wild rodents, and precautions for campers and hikers.
Strain-based control of crystal anisotropy for perovskite oxides on semiconductor-based material
McKee, Rodney Allen; Walker, Frederick Joseph
2000-01-01
A crystalline structure and a semiconductor device includes a substrate of a semiconductor-based material and a thin film of an anisotropic crystalline material epitaxially arranged upon the surface of the substrate so that the thin film couples to the underlying substrate and so that the geometries of substantially all of the unit cells of the thin film are arranged in a predisposed orientation relative to the substrate surface. The predisposition of the geometries of the unit cells of the thin film is responsible for a predisposed orientation of a directional-dependent quality, such as the dipole moment, of the unit cells. The predisposed orientation of the unit cell geometries are influenced by either a stressed or strained condition of the lattice at the interface between the thin film material and the substrate surface.
Multi-Wavelength Based Optical Density Sensor for Autonomous Monitoring of Microalgae
Jia, Fei; Kacira, Murat; Ogden, Kimberly L.
2015-01-01
A multi-wavelength based optical density sensor unit was designed, developed, and evaluated to monitor microalgae growth in real time. The system consisted of five main components including: (1) laser diode modules as light sources; (2) photodiodes as detectors; (3) driver circuit; (4) flow cell; and (5) sensor housing temperature controller. The sensor unit was designed to be integrated into any microalgae culture system for both real time and non-real time optical density measurements and algae growth monitoring applications. It was shown that the sensor unit was capable of monitoring the dynamics and physiological changes of the microalgae culture in real-time. Algae biomass concentration was accurately estimated with optical density measurements at 650, 685 and 780 nm wavelengths used by the sensor unit. The sensor unit was able to monitor cell concentration as high as 1.05 g·L−1 (1.51 × 108 cells·mL−1) during the culture growth without any sample preparation for the measurements. Since high cell concentrations do not need to be diluted using the sensor unit, the system has the potential to be used in industrial microalgae cultivation systems for real time monitoring and control applications that can lead to improved resource use efficiency. PMID:26364640
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-06
... controls, even if those parts or components are ``specially designed'' for a defense article on the USML or... using broad, design-intent based catch- all controls over generic types of items such as ``parts'' and... that multilateral regimes do not require that the United States control non-significant parts and the...
Johnson, L; Kwok, M; Marks, D C
2015-02-01
The ErySep system represents an alternative to centrifuge-based whole blood (WB) separation, using gravity and filtration through hollow-fibres (0·2 µm pore size) to produce red blood cell (RBC) and plasma components. The aim of this study was to characterise the quality of ErySep RBC and plasma units compared with standard products from WB held overnight. Two ABO-compatible WB units (n = 24) were pooled and split to produce matched products. One of the WB units was separated into components using the ErySep system (ErySep; n = 12), whereas the other units were separated by centrifugation (control; n = 12). RBC units were stored at 2-6 °C and assessed for in vitro quality over 42 days of storage. Plasma was frozen at -30 °C and tested upon thawing. Processing WB with the ErySep system took longer than controls. The ErySep RBC units were of an appropriate volume (307 ± 17 mL) and contained sufficient Hb (50 ± 2 g unit(-1) ). ErySep RBC components contained more microparticles relative to controls at expiry. The plasma volume, total protein, coagulation factor activity (fibrinogen, FV, FVIII) and number of microparticles was lower in the ErySep units compared with controls. Following overnight hold of WB, the ErySep system was capable of producing RBC components that met specifications. However, the ErySep plasma components did not meet quality specifications. © 2015 British Blood Transfusion Society.
1992-08-01
Executive Magdalen House Stanley Precinct, Bootle Merseyside L20 3QZ United Kingdom P. A. MORETON SRD of AEA Technology Wigshaw Lane Culcheth...Cheshire WA3 4NE United Kingdom INTRODUCTION The system of control imposed on explosives movements through ports in Great Britain is based on...regulations). Regulation 7 of CIMAH requires a person in control of a ’top-tier’ industrial activity to submit to the HSE a written safety report. Such a
Specifications Physiological Monitoring System
NASA Technical Reports Server (NTRS)
1985-01-01
The operation of a physiological monitoring system (PMS) is described. Specifications were established for performance, design, interface, and test requirements. The PMS is a compact, microprocessor-based system, which can be worn in a pack on the body or may be mounted on a Spacelab rack or other appropriate structure. It consists of two modules, the Data Control Unit (DCU) and the Remote Control/Display Unit (RCDU). Its purpose is to collect and distribute data from physiological experiments in the Spacelab and in the Orbiter.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-01-01
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments. PMID:27834839
ERIC Educational Resources Information Center
Tobacyk, Jerome J.; Tobacyk, Zofia Socha
1992-01-01
Uses Social Learning Theory to compare 149 university students from Poland with 136 university students from the southern United States for belief-based personality constructs and personality correlates of paranormal beliefs. As hypothesized, Poles reported a more external locus of control and significantly greater endorsement of irrational…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
Wireless Headset Communication System
NASA Technical Reports Server (NTRS)
Lau, Wilfred K.; Swanson, Richard; Christensen, Kurt K.
1995-01-01
System combines features of pagers, walkie-talkies, and cordless telephones. Wireless headset communication system uses digital modulation on spread spectrum to avoid interference among units. Consists of base station, 4 radio/antenna modules, and as many as 16 remote units with headsets. Base station serves as network controller, audio-mixing network, and interface to such outside services as computers, telephone networks, and other base stations. Developed for use at Kennedy Space Center, system also useful in industrial maintenance, emergency operations, construction, and airport operations. Also, digital capabilities exploited; by adding bar-code readers for use in taking inventories.
Wu, Xiao; Shen, Jiong; Li, Yiguo; Lee, Kwang Y
2014-05-01
This paper develops a novel data-driven fuzzy modeling strategy and predictive controller for boiler-turbine unit using fuzzy clustering and subspace identification (SID) methods. To deal with the nonlinear behavior of boiler-turbine unit, fuzzy clustering is used to provide an appropriate division of the operation region and develop the structure of the fuzzy model. Then by combining the input data with the corresponding fuzzy membership functions, the SID method is extended to extract the local state-space model parameters. Owing to the advantages of the both methods, the resulting fuzzy model can represent the boiler-turbine unit very closely, and a fuzzy model predictive controller is designed based on this model. As an alternative approach, a direct data-driven fuzzy predictive control is also developed following the same clustering and subspace methods, where intermediate subspace matrices developed during the identification procedure are utilized directly as the predictor. Simulation results show the advantages and effectiveness of the proposed approach. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Variations in incubator temperature and humidity management: a survey of current practice.
Deguines, C; Décima, P; Pelletier, A; Dégrugilliers, L; Ghyselen, L; Tourneux, P
2012-03-01
To describe and assess routine procedures and practices for incubator temperature and humidity management in France in 2009. A questionnaire was sent to all the 186 neonatal care units in France. The questionnaire return rate was 86%. Seventy-five per cent of the units preferred skin servo-control to air temperature control in routine practice. Air temperature control was mainly used for infants with a gestational age of more than 28 weeks and aged over 7 days of life. In general, thermal management decisions did not depend on the infant's age but were based on a protocol applied specifically by each unit. All units humidified the incubator air, but there was a large difference between the lowest and highest reported humidity values (45% and 100% assumed to be a maximal value, respectively). More than 65% of the units used a fixed humidity value, rather than a variable, protocol-derived value. We observed large variations in incubator temperature and humidity management approaches from one neonatal care unit to another. There is a need for more evidence to better inform practice. A task force should be formed to guide clinical practice. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.
Moy, Marilyn L.; Collins, Riley J.; Martinez, Carlos H.; Kadri, Reema; Roman, Pia; Holleman, Robert G.; Kim, Hyungjin Myra; Nguyen, Huong Q.; Cohen, Miriam D.; Goodrich, David E.; Giardino, Nicholas D.
2015-01-01
BACKGROUND: Low levels of physical activity (PA) are associated with poor outcomes in people with COPD. Interventions to increase PA could improve outcomes. METHODS: We tested the efficacy of a novel Internet-mediated, pedometer-based exercise intervention. Veterans with COPD (N = 239) were randomized in a 2:1 ratio to the (1) intervention group (Omron HJ-720 ITC pedometer and Internet-mediated program) or (2) wait-list control group (pedometer). The primary outcome was health-related quality of life (HRQL), assessed by the St. George’s Respiratory Questionnaire (SGRQ), at 4 months. We examined the SGRQ total score (SGRQ-TS) and three domain scores: Symptoms, Activities, and Impact. The secondary outcome was daily step counts. Linear regression models assessed the effect of intervention on outcomes. RESULTS: Participants had a mean age of 67 ± 9 years, and 94% were men. There was no significant between-group difference in mean 4-month SGRQ-TS (2.3 units, P = .14). Nevertheless, a significantly greater proportion of intervention participants than control subjects had at least a 4-unit improvement in SGRQ-TS, the minimum clinically important difference (53% vs 39%, respectively, P = .05). For domain scores, the intervention group had a lower (reflecting better HRQL) mean than the control group by 4.6 units for Symptoms (P = .046) and by 3.3 units for Impact (P = .049). There was no significant difference in Activities score between the two groups. Compared with the control subjects, intervention participants walked 779 more steps per day at 4 months (P = .005). CONCLUSIONS: An Internet-mediated, pedometer-based walking program can improve domains of HRQL and daily step counts at 4 months in people with COPD. TRIAL REGISTRY: Clinical Trials.gov; No.: NCT01102777; URL: www.clinicaltrials.gov PMID:25811395
Coordinated control system modelling of ultra-supercritical unit based on a new T-S fuzzy structure.
Hou, Guolian; Du, Huan; Yang, Yu; Huang, Congzhi; Zhang, Jianhua
2018-03-01
The thermal power plant, especially the ultra-supercritical unit is featured with severe nonlinearity, strong multivariable coupling. In order to deal with these difficulties, it is of great importance to build an accurate and simple model of the coordinated control system (CCS) in the ultra-supercritical unit. In this paper, an improved T-S fuzzy model identification approach is proposed. First of all, the k-means++ algorithm is employed to identify the premise parameters so as to guarantee the number of fuzzy rules. Then, the local linearized models are determined by using the incremental historical data around the cluster centers, which are obtained via the stochastic gradient descent algorithm with momentum and variable learning rate. Finally, with the proposed method, the CCS model of a 1000 MW USC unit in Tai Zhou power plant is developed. The effectiveness of the proposed approach is validated by the given extensive simulation results, and it can be further employed to design the overall advanced controllers for the CCS in an USC unit. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sedov, A. V.; Kalinchuk, V. V.; Bocharova, O. V.
2018-01-01
The evaluation of static stresses and strength of units and components is a crucial task for increasing reliability in the operation of vehicles and equipment, to prevent emergencies, especially in structures made of metal and composite materials. At the stage of creation and commissioning of structures to control the quality of manufacturing of individual elements and components, diagnostic control methods are widely used. They are acoustic, ultrasonic, X-ray, radiation methods and others. The using of these methods to control the residual life and the degree of static stresses of units and parts during operation is fraught with great difficulties both in methodology and in instrumentation. In this paper, the authors propose an effective approach of operative control of the degree of static stresses of units and parts of mechanical structures which are in working condition, based on recording the changing in the surface wave properties of a system consisting of a sensor and a controlled environment (unit, part). The proposed approach of low-frequency diagnostics of static stresses presupposes a new adaptive-spectral analysis of a surface wave created by external action (impact). It is possible to estimate implicit stresses of structures in the experiment due to this approach.
Barrett, Damon
2010-03-01
This commentary addresses some of the challenges posed by the broader normative, legal and policy framework of the United Nations for the international drug control system. The 'purposes and principles' of the United Nations are presented and set against the threat based rhetoric of the drug control system and the negative consequences of that system. Some of the challenges posed by human rights law and norms to the international drug control system are also described, and the need for an impact assessment of the current system alongside alternative policy options is highlighted as a necessary consequence of these analyses. Copyright (c) 2010 Elsevier B.V. All rights reserved.
1988-11-01
Manufacturing System 22 4. Similar Parts Based Shape or Manufactuting Process 24 5. Projected Annual Unit Robot Sales and Installed Base Through 1992 30 6. U.S...effort needed to perform personnel, product design, marketing , and advertising, and finance tasks of the firm. Level III controls the resource...planning and accounting functions of the firm. Systems at this level support purchasing, accounts payable, accounts receivable, master scheduling and sales
Reliability modelling and analysis of a multi-state element based on a dynamic Bayesian network
Xu, Tingxue; Gu, Junyuan; Dong, Qi; Fu, Linyu
2018-01-01
This paper presents a quantitative reliability modelling and analysis method for multi-state elements based on a combination of the Markov process and a dynamic Bayesian network (DBN), taking perfect repair, imperfect repair and condition-based maintenance (CBM) into consideration. The Markov models of elements without repair and under CBM are established, and an absorbing set is introduced to determine the reliability of the repairable element. According to the state-transition relations between the states determined by the Markov process, a DBN model is built. In addition, its parameters for series and parallel systems, namely, conditional probability tables, can be calculated by referring to the conditional degradation probabilities. Finally, the power of a control unit in a failure model is used as an example. A dynamic fault tree (DFT) is translated into a Bayesian network model, and subsequently extended to a DBN. The results show the state probabilities of an element and the system without repair, with perfect and imperfect repair, and under CBM, with an absorbing set plotted by differential equations and verified. Through referring forward, the reliability value of the control unit is determined in different kinds of modes. Finally, weak nodes are noted in the control unit. PMID:29765629
Hane, Amie A; Myers, Michael M; Hofer, Myron A; Ludwig, Robert J; Halperin, Meeka S; Austin, Judy; Glickstein, Sara B; Welch, Martha G
2015-04-01
This study assessed the impact of Family Nurture Intervention (FNI) on the quality of maternal caregiving behavior (MCB) while in the neonatal intensive care unit (NICU). FNI is a randomized controlled trial conducted in a high-acuity NICU to facilitate an emotional connection between mothers and their premature infants. FNI begins shortly after birth, continues until discharge, and involves mother/infant calming sessions that include scent cloth exchange, vocal soothing and emotion expression, eye contact, skin-to-skin and clothed holding, and family-based support sessions. Maternal caregiving behavior was coded during a single holding and feeding session (∼30 min) in the NICU before discharge at approximately 36 weeks gestational age (GA). Sixty-five mothers and their premature infants (34 male, 31 female; 26-34 wk GA) were included in these analyses (FNI, n = 35; standard care [SC], n = 30). Relative to mothers in the SC condition, those in the FNI group showed significantly higher quality MCB, which remained significant when controlling for birth order, twin status, maternal depression, and maternal anxiety. This is the first study to demonstrate that in-unit MCB can be enhanced by a hospital-based intervention. FNI provides a new rationale for integrating nurture-based interventions into standard NICU care.
Research and application of thermal power unit’s load dynamic adjustment based on extraction steam
NASA Astrophysics Data System (ADS)
Li, Jun; Li, Huicong; Li, Weiwei
2018-02-01
The rapid development of heat and power generation in large power plant has caused tremendous constraints on the load adjustment of power grids and power plants. By introducing the thermodynamic system of thermal power unit, the relationship between thermal power extraction steam and unit’s load has analyzed and calculated. The practical application results show that power capability of the unit affected by extraction and it is not conducive to adjust the grid frequency. By monitoring the load adjustment capacity of thermal power units, especially the combined heat and power generating units, the upper and lower limits of the unit load can be dynamically adjusted by the operator on the grid side. The grid regulation and control departments can effectively control the load adjustable intervals of the operating units and provide reliable for the cooperative action of the power grid and power plants, to ensure the safety and stability of the power grid.
Decentralized control of sound radiation using iterative loop recovery.
Schiller, Noah H; Cabell, Randolph H; Fuller, Chris R
2010-10-01
A decentralized model-based control strategy is designed to reduce low-frequency sound radiation from periodically stiffened panels. While decentralized control systems tend to be scalable, performance can be limited due to modeling error introduced by the unmodeled interaction between neighboring control units. Since bounds on modeling error are not known in advance, it is difficult to ensure the decentralized control system will be robust without making the controller overly conservative. Therefore an iterative approach is suggested, which utilizes frequency-shaped loop recovery. The approach accounts for modeling error introduced by neighboring control loops, requires no communication between subsystems, and is relatively simple. The control strategy is evaluated numerically using a model of a stiffened aluminum panel that is representative of the sidewall of an aircraft. Simulations demonstrate that the iterative approach can achieve significant reductions in radiated sound power from the stiffened panel without destabilizing neighboring control units.
Decentralized Control of Sound Radiation Using Iterative Loop Recovery
NASA Technical Reports Server (NTRS)
Schiller, Noah H.; Cabell, Randolph H.; Fuller, Chris R.
2009-01-01
A decentralized model-based control strategy is designed to reduce low-frequency sound radiation from periodically stiffened panels. While decentralized control systems tend to be scalable, performance can be limited due to modeling error introduced by the unmodeled interaction between neighboring control units. Since bounds on modeling error are not known in advance, it is difficult to ensure the decentralized control system will be robust without making the controller overly conservative. Therefore an iterative approach is suggested, which utilizes frequency-shaped loop recovery. The approach accounts for modeling error introduced by neighboring control loops, requires no communication between subsystems, and is relatively simple. The control strategy is evaluated numerically using a model of a stiffened aluminum panel that is representative of the sidewall of an aircraft. Simulations demonstrate that the iterative approach can achieve significant reductions in radiated sound power from the stiffened panel without destabilizing neighboring control units.
NASA Astrophysics Data System (ADS)
Ligori, S.; Corcione, L.; Capobianco, V.; Bonino, D.; Sirri, G.; Fornari, F.; Giacomini, F.; Patrizii, L.; Valenziano, L.; Travaglini, R.; Colodro, C.; Bortoletto, F.; Bonoli, C.; Chiarusi, T.; Margiotta, A.; Mauri, N.; Pasqualini, L.; Spurio, M.; Tenti, M.; Dal Corso, F.; Dusini, S.; Laudisio, F.; Sirignano, C.; Stanco, L.; Ventura, S.; Auricchio, N.; Balestra, A.; Franceschi, E.; Morgante, G.; Trifoglio, M.; Medinaceli, E.; Guizzo, G. P.; Debei, S.; Stephen, J. B.
2016-07-01
In this paper we describe the detailed design of the application software (ASW) of the instrument control unit (ICU) of NISP, the Near-Infrared Spectro-Photometer of the Euclid mission. This software is based on a real-time operating system (RTEMS) and will interface with all the subunits of NISP, as well as the command and data management unit (CDMU) of the spacecraft for telecommand and housekeeping management. We briefly review the main requirements driving the design and the architecture of the software that is approaching the Critical Design Review level. The interaction with the data processing unit (DPU), which is the intelligent subunit controlling the detector system, is described in detail, as well as the concept for the implementation of the failure detection, isolation and recovery (FDIR) algorithms. The first version of the software is under development on a Breadboard model produced by AIRBUS/CRISA. We describe the results of the tests and the main performances and budgets.
Lintilhac, Phillip M.; Vesecky, Thompson B.
1995-01-01
Apparatus and methods are disclosed facilitating the application of forces and measurement of dimensions of a test subject. In one arrangement the test subject is coupled to a forcing frame and controlled forces applied thereto. Force applied to the test subject is measured and controlled. A dimensional characteristic of the test subject, such as growth, is measured by a linear variable differential transformer. The growth measurement data can be used to control the force applied. The transducer module receives force and dimensional data from the forcing frame. The transducer module is a separate, microprocessor-based unit that communicates the test data to a controller unit that controls the application of force to the test subject and receives the test data from the transducer module for force control, storage, and/or communication to the user.
Lintilhac, P.M.; Vesecky, T.B.
1995-09-19
An apparatus and methods are disclosed facilitating the application of forces and measurement of dimensions of a test subject. In one arrangement the test subject is coupled to a forcing frame and controlled forces applied thereto. Force applied to the test subject is measured and controlled. A dimensional characteristic of the test subject, such as growth, is measured by a linear variable differential transformer. The growth measurement data can be used to control the force applied. The transducer module receives force and dimensional data from the forcing frame. The transducer module is a separate, microprocessor-based unit that communicates the test data to a controller unit that controls the application of force to the test subject and receives the test data from the transducer module for force control, storage, and/or communication to the user. 8 figs.
A configurable electronics system for the ESS-Bilbao beam position monitors
NASA Astrophysics Data System (ADS)
Muguira, L.; Belver, D.; Etxebarria, V.; Varnasseri, S.; Arredondo, I.; del Campo, M.; Echevarria, P.; Garmendia, N.; Feuchtwanger, J.; Jugo, J.; Portilla, J.
2013-09-01
A versatile and configurable system has been developed in order to monitorize the beam position and to meet all the requirements of the future ESS-Bilbao Linac. At the same time the design has been conceived to be open and configurable so that it could eventually be used in different kinds of accelerators, independent of the charged particle, with minimal change. The design of the Beam Position Monitors (BPMs) system includes a test bench both for button-type pick-ups (PU) and striplines (SL), the electronic units and the control system. The electronic units consist of two main parts. The first part is an Analog Front-End (AFE) unit where the RF signals are filtered, conditioned and converted to base-band. The second part is a Digital Front-End (DFE) unit which is based on an FPGA board where the base-band signals are sampled in order to calculate the beam position, the amplitude and the phase. To manage the system a Multipurpose Controller (MC) developed at ESSB has been used. It includes the FPGA management, the EPICS integration and Archiver Instances. A description of the system and a comparison between the performance of both PU and SL BPM designs measured with this electronics system are fully described and discussed.
TELICS—A Telescope Instrument Control System for Small/Medium Sized Astronomical Observatories
NASA Astrophysics Data System (ADS)
Srivastava, Mudit K.; Ramaprakash, A. N.; Burse, Mahesh P.; Chordia, Pravin A.; Chillal, Kalpesh S.; Mestry, Vilas B.; Das, Hillol K.; Kohok, Abhay A.
2009-10-01
For any modern astronomical observatory, it is essential to have an efficient interface between the telescope and its back-end instruments. However, for small and medium-sized observatories, this requirement is often limited by tight financial constraints. Therefore a simple yet versatile and low-cost control system is required for such observatories to minimize cost and effort. Here we report the development of a modern, multipurpose instrument control system TELICS (Telescope Instrument Control System) to integrate the controls of various instruments and devices mounted on the telescope. TELICS consists of an embedded hardware unit known as a common control unit (CCU) in combination with Linux-based data acquisition and user interface. The hardware of the CCU is built around the ATmega 128 microcontroller (Atmel Corp.) and is designed with a backplane, master-slave architecture. A Qt-based graphical user interface (GUI) has been developed and the back-end application software is based on C/C++. TELICS provides feedback mechanisms that give the operator good visibility and a quick-look display of the status and modes of instruments as well as data. TELICS has been used for regular science observations since 2008 March on the 2 m, f/10 IUCAA Telescope located at Girawali in Pune, India.
A knowledge based application of the extended aircraft interrogation and display system
NASA Technical Reports Server (NTRS)
Glover, Richard D.; Larson, Richard R.
1991-01-01
A family of multiple-processor ground support test equipment was used to test digital flight-control systems on high-performance research aircraft. A unit recently built for the F-18 high alpha research vehicle project is the latest model in a series called the extended aircraft interrogation and display system. The primary feature emphasized monitors the aircraft MIL-STD-1553B data buses and provides real-time engineering units displays of flight-control parameters. A customized software package was developed to provide real-time data interpretation based on rules embodied in a highly structured knowledge database. The configuration of this extended aircraft interrogation and display system is briefly described, and the evolution of the rule based package and its application to failure modes and effects testing on the F-18 high alpha research vehicle is discussed.
Research on optimization of combustion efficiency of thermal power unit based on genetic algorithm
NASA Astrophysics Data System (ADS)
Zhou, Qiongyang
2018-04-01
In order to improve the economic performance and reduce pollutant emissions of thermal power units, the characteristics of neural network in establishing boiler combustion model are analyzed based on the analysis of the main factors affecting boiler efficiency by using orthogonal method. In addition, on the basis of this model, the genetic algorithm is used to find the best control amount of the furnace combustion in a certain working condition. Through the genetic algorithm based on real number encoding and roulette selection is concluded: the best control quantity at a condition of furnace combustion can be combined with the boiler combustion system model for neural network training. The precision of the neural network model is further improved, and the basic work is laid for the research of the whole boiler combustion optimization system.
NASA Technical Reports Server (NTRS)
Hewes, D. E.; Glover, K. E.
1975-01-01
A Skylab experiment was conducted to study the maneuvering capabilities of astronauts using a relatively simple self-locomotive device, referred to as the foot-controlled maneuvering unit, and to evaluate the effectiveness of ground-based facilities simulating the operation of this device in weightless conditions of space. Some of the special considerations given in the definition and development of the experiment as related to the two ground-based simulators are reviewed. These simulators were used to train the test subjects and to obtain baseline data which could be used for comparison with the in-flight tests that were performed inside the Skylab orbital workshop. The results of both premission and postmission tests are discussed, and subjective comparisons of the in-flight and ground-based test conditions are presented.
The afocal telescope of the ESA ARIEL mission: analysis of the layout
NASA Astrophysics Data System (ADS)
Da Deppo, Vania; Middleton, Kevin; Focardi, Mauro; Morgante, Gianluca; Corso, Alain Jody; Pace, Emanuele; Claudi, Riccardo; Micela, Giuseppina
2017-09-01
ARIEL (Atmospheric Remote-sensing Infrared Exoplanet Large-survey) is one of the three present candidates as an M4 ESA mission to be launched in 2026. During its foreseen 3.5 years operation, it will observe spectroscopically in the infrared a large population of known transiting planets in the neighborhood of the Solar System. The aim is to enable a deep understanding of the physics and chemistry of these exoplanets. ARIEL is based on a 1-m class telescope ahead of a suite of instruments: two spectrometer channels covering the band 1.95 to 7.8 μm and four photometric channels (two wide and two narrow band) in the range 0.5 to 1.9 μm. The ARIEL optical design is conceived as a fore-module common afocal telescope that will feed the spectrometer and photometric channels. The telescope optical design is based on an eccentric pupil two-mirror classic Cassegrain configuration coupled to a tertiary paraboloidal mirror. The temperature of the primary mirror (M1) will be monitored and finely tuned by means of an active thermal control system based on thermistors and heaters. They will be switched on and off to maintain the M1 temperature within ±1 K thanks to a proportional-integral-derivative (PID) controller implemented within the Telescope Control Unit (TCU), a Payload electronics subsystem mainly in charge of the active thermal control of the two detectors owning to the spectrometer. TCU will collect the housekeeping data of the controlled subsystems and will forward them to the spacecraft (S/C) by means of the Instrument Control Unit (ICU), the main Payload's electronic Unit linked to the S/C On Board Computer (OBC).
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
2016-01-01
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program
NASA Technical Reports Server (NTRS)
Hansen, Patricia A.; Townsend, Jacqueline A.; Hedgeland, Randy J.
2004-01-01
Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST &om contamination and the instruments from self-contamination.
Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program
NASA Technical Reports Server (NTRS)
Hansen, Patricia A.; Townsend, Jacqueline A.; Hedgeland, Randy J.
2004-01-01
Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST from contamination and the instruments from self-contamination.
CSI computer system/remote interface unit acceptance test results
NASA Technical Reports Server (NTRS)
Sparks, Dean W., Jr.
1992-01-01
The validation tests conducted on the Control/Structures Interaction (CSI) Computer System (CCS)/Remote Interface Unit (RIU) is discussed. The CCS/RIU consists of a commercially available, Langley Research Center (LaRC) programmed, space flight qualified computer and a flight data acquisition and filtering computer, developed at LaRC. The tests were performed in the Space Structures Research Laboratory (SSRL) and included open loop excitation, closed loop control, safing, RIU digital filtering, and RIU stand alone testing with the CSI Evolutionary Model (CEM) Phase-0 testbed. The test results indicated that the CCS/RIU system is comparable to ground based systems in performing real-time control-structure experiments.
Decentralized control of units in smart grids for the support of renewable energy supply
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonnenschein, Michael, E-mail: Michael.Sonnenschein@Uni-Oldenburg.DE; Lünsdorf, Ontje, E-mail: Ontje.Luensdorf@OFFIS.DE; Bremer, Jörg, E-mail: Joerg.Bremer@Uni-Oldenburg.DE
Due to the significant environmental impact of power production from fossil fuels and nuclear fission, future energy systems will increasingly rely on distributed and renewable energy sources (RES). The electrical feed-in from photovoltaic (PV) systems and wind energy converters (WEC) varies greatly both over short and long time periods (from minutes to seasons), and (not only) by this effect the supply of electrical power from RES and the demand for electrical power are not per se matching. In addition, with a growing share of generation capacity especially in distribution grids, the top-down paradigm of electricity distribution is gradually replaced bymore » a bottom-up power supply. This altogether leads to new problems regarding the safe and reliable operation of power grids. In order to address these challenges, the notion of Smart Grids has been introduced. The inherent flexibilities, i.e. the set of feasible power schedules, of distributed power units have to be controlled in order to support demand–supply matching as well as stable grid operation. Controllable power units are e.g. combined heat and power plants, power storage systems such as batteries, and flexible power consumers such as heat pumps. By controlling the flexibilities of these units we are particularly able to optimize the local utilization of RES feed-in in a given power grid by integrating both supply and demand management measures with special respect to the electrical infrastructure. In this context, decentralized systems, autonomous agents and the concept of self-organizing systems will become key elements of the ICT based control of power units. In this contribution, we first show how a decentralized load management system for battery charging/discharging of electrical vehicles (EVs) can increase the locally used share of supply from PV systems in a low voltage grid. For a reliable demand side management of large sets of appliances, dynamic clustering of these appliances into uniformly controlled appliance sets is necessary. We introduce a method for self-organized clustering for this purpose and show how control of such clusters can affect load peaks in distribution grids. Subsequently, we give a short overview on how we are going to expand the idea of self-organized clusters of units into creating a virtual control center for dynamic virtual power plants (DVPP) offering products at a power market. For an efficient organization of DVPPs, the flexibilities of units have to be represented in a compact and easy to use manner. We give an introduction how the problem of representing a set of possibly 10{sup 100} feasible schedules can be solved by a machine-learning approach. In summary, this article provides an overall impression how we use agent based control techniques and methods of self-organization to support the further integration of distributed and renewable energy sources into power grids and energy markets. - Highlights: • Distributed load management for electrical vehicles supports local supply from PV. • Appliances can self-organize into so called virtual appliances for load control. • Dynamic VPPs can be controlled by extensively decentralized control centers. • Flexibilities of units can efficiently be represented by support-vector descriptions.« less
Automated Cryocooler Monitor and Control System Software
NASA Technical Reports Server (NTRS)
Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad
2011-01-01
This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.
1983-09-01
which were based on off-season, summer prices and demand C4 143-8], and placed mandatory controls on all petroleum product prices s6:136]. These...Service, September 1982. Hausman , J. A., and P. L. Joskow. "Evaluating the Costs and Benefits of Appliance Efficiency Standards," American Economic...Department of Agriculture, Washington: United States Government Printing Office, March 4, 1989. Zoch, Lawrence L., Jr., Jack J. Rusch, and Edward L. Springer
Siegel, Michael; DeJong, William; Albers, Alison B; Naimi, Timothy S; Jernigan, David H
2013-02-01
This study aims to compare the average price of liquor in the United States between retail alcohol outlets in states that have a monopoly ('control' states) with those that do not ('licence' states). A cross-sectional study of brand-specific alcohol prices in the United States. We determined the average prices in February 2012 of 74 brands of liquor among the 13 control states that maintain a monopoly on liquor sales at the retail level and among a sample of 50 license-state liquor stores, using their online-available prices. We calculated average prices for 74 brands of liquor by control versus license state. We used a random-effects regression model to estimate differences between control and license state prices-overall and by alcoholic beverage type. We also compared prices between the 13 control states. The overall mean price for the 74 brands was $27.79 in the license states [95% confidence interval (CI): $25.26-30.32] and $29.82 in the control states (95% CI: $26.98-32.66). Based on the random-effects linear regression model, the average liquor price was approximately $2 lower (6.9% lower) in license states. In the United States monopoly of alcohol retail outlets appears to be associated with slightly higher liquor prices. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.
Characterization of the Advanced Stirling Radioisotope Generator Engineering Unit 2
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Oriti, Salvatore M.; Schifer, Niholas A.
2016-01-01
Significant progress was made developing the Advanced Stirling Radioisotope Generator (ASRG) 140-W radioisotope power system. While the ASRG flight development project has ended, the hardware that was designed and built under the project is continuing to be tested to support future Stirling-based power system development. NASA Glenn Research Center recently completed the assembly of the ASRG Engineering Unit 2 (EU2). The ASRG EU2 consists of the first pair of Sunpower's Advanced Stirling Convertor E3 (ASC-E3) Stirling convertors mounted in an aluminum housing, and Lockheed Martin's Engineering Development Unit (EDU) 4 controller (a fourth-generation controller). The ASC-E3 convertors and Generator Housing Assembly (GHA) closely match the intended ASRG Qualification Unit flight design. A series of tests were conducted to characterize the EU2, its controller, and the convertors in the flight-like GHA. The GHA contained an argon cover gas for these tests. The tests included measurement of convertor, controller, and generator performance and efficiency; quantification of control authority of the controller; disturbance force measurement with varying piston phase and piston amplitude; and measurement of the effect of spacecraft direct current (DC) bus voltage on EU2 performance. The results of these tests are discussed and summarized, providing a basic understanding of EU2 characteristics and the performance and capability of the EDU 4 controller.
Meller, Michael; Chipka, Jordan; Volkov, Alexander; Bryant, Matthew; Garcia, Ephrahim
2016-11-03
Hydraulic control systems have become increasingly popular as the means of actuation for human-scale legged robots and assistive devices. One of the biggest limitations to these systems is their run time untethered from a power source. One way to increase endurance is by improving actuation efficiency. We investigate reducing servovalve throttling losses by using a selective recruitment artificial muscle bundle comprised of three motor units. Each motor unit is made up of a pair of hydraulic McKibben muscles connected to one servovalve. The pressure and recruitment state of the artificial muscle bundle can be adjusted to match the load in an efficient manner, much like the firing rate and total number of recruited motor units is adjusted in skeletal muscle. A volume-based effective initial braid angle is used in the model of each recruitment level. This semi-empirical model is utilized to predict the efficiency gains of the proposed variable recruitment actuation scheme versus a throttling-only approach. A real-time orderly recruitment controller with pressure-based thresholds is developed. This controller is used to experimentally validate the model-predicted efficiency gains of recruitment on a robot arm. The results show that utilizing variable recruitment allows for much higher efficiencies over a broader operating envelope.
High-authority smart material integrated electric actuator
NASA Astrophysics Data System (ADS)
Weisensel, G. N.; Pierce, Thomas D.; Zunkel, Gary
1997-05-01
For many current applications, hydraulic power is still the preferred method of gaining mechanical advantage. However, in many of these applications, this power comes with the penalties of high weight, size, cost, and maintenance due to the system's distributed nature and redundancy requirements. A high authority smart material Integrated Electric Actuator (IEA) is a modular, self-contained linear motion device that is capable of producing dynamic output strokes similar to those of hydraulic actuators yet at significantly reduced weight and volume. It provides system simplification and miniaturization. This actuator concept has many innovative features, including a TERFENOL-D-based pump, TERFENOL-D- based active valves, control algorithms, a displacement amplification unit and integrated, unitized packaging. The IEA needs only electrical power and a control command signal as inputs to provide high authority, high response rate actuation. This approach is directly compatible with distributed control strategies. Aircraft control, automotive brakes and fuel injection, and fluid power delivery are just some examples of the IEA's pervasive applications in aerospace, defense and commercial systems.
Adherence to infection control guidelines in surgery on MRSA positive patients : A cost analysis.
Saegeman, V; Schuermans, A
2016-09-01
In surgical units, similar to other healthcare departments, guidelines are used to curb transmission of methicillin resistant Staphylococcus aureus (MRSA). The aim of this study was to calculate the extra costs for material and extra working hours for compliance to MRSA infection control guidelines in the operating rooms of a University Hospital. The study was based on observations of surgeries on MRSA positive patients. The average cost per surgery was calculated utilizing local information on unit costs. Robustness of the calculations was evaluated with a sensitivity analysis. The total extra costs of adherence to MRSA infection control guidelines averaged € 340.46 per surgical procedure (range € 207.76- € 473.15). A sensitivity analysis based on a standardized operating room hourly rate reached a cost of € 366.22. The extra costs of adherence to infection control guidelines are considerable. To reduce costs, the logistical planning of surgeries could be improved by for instance a dedicated room.
Freitas, Ângela M; Portuguez, Mirna Wetters; Russomano, Thaís; Freitas, Marcos de; Silvello, Silvio Luis da Silva; Costa, Jaderson Costa da
2017-10-01
To evaluate symptoms of stress and excessive daytime sleepiness (EDS) in air traffic control (ATC) officers in Brazil. Fifty-two ATC officers participated, based at three air traffic control units, identified as A, B and C. Stress symptoms were assessed using the Lipp Inventory of Stress Symptoms for Adults, and EDS by the Epworth Sleepiness Scale. The sample mean age was 37 years, 76.9% of whom were male. Excessive daytime sleepiness was identified in 25% of the ATC officers, with 84.6% of these based at air traffic control unit A, which has greater air traffic flow, operating a 24-hour alternating work shift schedule. A total of 16% of the ATC officers had stress symptoms, and of these, 62% showed a predominance of physical symptoms. The high percentage of ATC officers with EDS identified in group A may be related to chronodisruption due to night work and alternating shifts.
119. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), ...
119. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751). POWER DISTRIBUTION UNITS AND CABLE DISTRIBUTION UNITS ON RIGHT SIDE OF PHOTO; LOGIC CONTROL AND MONITOR UNITS FOR BOOSTER AND FUEL SYSTEMS LEFT OF AND PARALLEL TO EAST ROW OF CABINETS; SIGNAL CONDITIONERS AT NORTH END OF ROOM PERPENDICULAR TO OTHER CABINETS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Saulnier, George E; Castro, Janna C; Cook, Curtiss B
2014-05-01
Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box-Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. © 2014 Diabetes Technology Society.
Saulnier, George E.; Castro, Janna C.
2014-01-01
Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box–Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. PMID:24876620
ERIC Educational Resources Information Center
Rains, Larry
This engine performance (emission control systems) module is one of a series of competency-based modules in the Missouri Auto Mechanics Curriculum Guide. Topics of this module's five units are: positive crankcase ventilation (PCV) and evaporative emission control systems; exhaust gas recirculation (EGR); air injection and catalytic converters;…
Collective Actors and Corporate Targets in Tobacco Control: A Cross-National Comparison
ERIC Educational Resources Information Center
Nathanson, Constance A.
2005-01-01
Cross-national comparative analysis of tobacco control strategies can alert health advocates to how opportunities for public health action, types of action, and probabilities for success are shaped by political systems and cultures. This article is based on case studies of tobacco control in the United States, Canada, Britain, and France. Two…
Expert Panel Consensus for and Analysis of Key Attributes on Websites Devoted to Weight Control
ERIC Educational Resources Information Center
Brown, Stephen L.; Land, Diane; Johnson, Chandrika; Miller, Kim
2014-01-01
Background: Obesity presents major challenges to public health in the United States. Trials of web-based interventions for weight control suggest that the Internet is a promising option for program delivery. Purpose: This study sought consensus among experts regarding critical components of successful weight control and to systematically examine…
Evolution of the VLT instrument control system toward industry standards
NASA Astrophysics Data System (ADS)
Kiekebusch, Mario J.; Chiozzi, Gianluca; Knudstrup, Jens; Popovic, Dan; Zins, Gerard
2010-07-01
The VLT control system is a large distributed system consisting of Linux Workstations providing the high level coordination and interfaces to the users, and VME-based Local Control Units (LCU's) running the VxWorks real-time operating system with commercial and proprietary boards acting as the interface to the instrument functions. After more than 10 years of VLT operations, some of the applied technologies used by the astronomical instruments are being discontinued making it difficult to find adequate hardware for future projects. In order to deal with this obsolescence, the VLT Instrumentation Framework is being extended to adopt well established Commercial Off The Shelf (COTS) components connected through industry standard fieldbuses. This ensures a flexible state of the art hardware configuration for the next generation VLT instruments allowing the access to instrument devices via more compact and simpler control units like PC-based Programmable Logical Controllers (PLC's). It also makes it possible to control devices directly from the Instrument Workstation through a normal Ethernet connection. This paper outlines the requirements that motivated this work, as well as the architecture and the design of the framework extension. In addition, it describes the preliminary results on a use case which is a VLTI visitor instrument used as a pilot project to validate the concepts and the suitability of some COTS products like a PC-based PLCs, EtherCAT8 and OPC UA6 as solutions for instrument control.
Electrical Prototype Power Processor for the 30-cm Mercury electric propulsion engine
NASA Technical Reports Server (NTRS)
Biess, J. J.; Frye, R. J.
1978-01-01
An Electrical Prototpye Power Processor has been designed to the latest electrical and performance requirements for a flight-type 30-cm ion engine and includes all the necessary power, command, telemetry and control interfaces for a typical electric propulsion subsystem. The power processor was configured into seven separate mechanical modules that would allow subassembly fabrication, test and integration into a complete power processor unit assembly. The conceptual mechanical packaging of the electrical prototype power processor unit demonstrated the relative location of power, high voltage and control electronic components to minimize electrical interactions and to provide adequate thermal control in a vacuum environment. Thermal control was accomplished with a heat pipe simulator attached to the base of the modules.
[Integrated Development of Full-automatic Fluorescence Analyzer].
Zhang, Mei; Lin, Zhibo; Yuan, Peng; Yao, Zhifeng; Hu, Yueming
2015-10-01
In view of the fact that medical inspection equipment sold in the domestic market is mainly imported from abroad and very expensive, we developed a full-automatic fluorescence analyzer in our center, presented in this paper. The present paper introduces the hardware architecture design of FPGA/DSP motion controlling card+PC+ STM32 embedded micro processing unit, software system based on C# multi thread, design and implementation of double-unit communication in detail. By simplifying the hardware structure, selecting hardware legitimately and adopting control system software to object-oriented technology, we have improved the precision and velocity of the control system significantly. Finally, the performance test showed that the control system could meet the needs of automated fluorescence analyzer on the functionality, performance and cost.
NASA Astrophysics Data System (ADS)
Lazzari, R.; Parma, C.; De Marco, A.; Bittanti, S.
2015-07-01
In this paper, we describe a control strategy for a photovoltaic (PV) power plant equipped with an energy storage system (ESS), based on lithium-ion battery. The plant consists of the following units: the PV generator, the energy storage system, the DC-bus and the inverter. The control, organised in a hierarchical manner, maximises the self-consumption of the local load unit. In particular, the ESS action performs power balance in case of low solar radiation or surplus of PV generation, thus managing the power exchange variability at the plant with the grid. The implemented control strategy is under testing in RSE pilot test facility in Milan, Italy.
Enhanced Motor Imagery-Based BCI Performance via Tactile Stimulation on Unilateral Hand.
Shu, Xiaokang; Yao, Lin; Sheng, Xinjun; Zhang, Dingguo; Zhu, Xiangyang
2017-01-01
Brain-computer interface (BCI) has attracted great interests for its effectiveness in assisting disabled people. However, due to the poor BCI performance, this technique is still far from daily-life applications. One of critical issues confronting BCI research is how to enhance BCI performance. This study aimed at improving the motor imagery (MI) based BCI accuracy by integrating MI tasks with unilateral tactile stimulation (Uni-TS). The effects were tested on both healthy subjects and stroke patients in a controlled study. Twenty-two healthy subjects and four stroke patients were recruited and randomly divided into a control-group and an enhanced-group. In the control-group, subjects performed two blocks of conventional MI tasks (left hand vs. right hand), with 80 trials in each block. In the enhanced-group, subjects also performed two blocks of MI tasks, but constant tactile stimulation was applied on the non-dominant/paretic hand during MI tasks in the second block. We found the Uni-TS significantly enhanced the contralateral cortical activations during MI of the stimulated hand, whereas it had no influence on activation patterns during MI of the non-stimulated hand. The two-class BCI decoding accuracy was significantly increased from 72.5% (MI without Uni-TS) to 84.7% (MI with Uni-TS) in the enhanced-group ( p < 0.001, paired t -test). Moreover, stroke patients in the enhanced-group achieved an accuracy >80% during MI with Uni-TS. This novel approach complements the conventional methods for BCI enhancement without increasing source information or complexity of signal processing. This enhancement via Uni-TS may facilitate clinical applications of MI-BCI.
NASA Astrophysics Data System (ADS)
Roy, M.; Sengupta, M.
2012-09-01
Induction heating is a non-contact heating process which became popular due to its energy efficiency. Current source inverter (CSI) based induction heating units are commonly used in the industry. Most of these CSIs are thyristor based, since thyristors of higher ratings are easily available. These being load commutated apparatus a start-up circuit is needed to initiate commutation. In this paper the design and fabrication of two laboratory prototypes have been presented. The first one, a SCR-based CSI fed controlled induction heating unit (IHU), has been tested with two different types of start-up procedures. Thereafter the fabrication and performance of another IGBT-based CSI is compared with the thyristor-based CSI for a 2 kW, 10 kHz application. These two types of CSIs are fully fabricated in laboratory along with the IHU. Performance analysis and simulation of two different CSIs has been done by using SequelGUI2. The triggering pulses for the inverter devices (for both CSI devices as well as auxilliary thyristor of start-up circuit) have been generated and closed-loop control has been done in FPGA platform built around an Altera make cyclone EPIC12Q240C processor which can be programmed using Quartus II software. Close agreement between simulated and experimental results highlight the accuracy of the experimental work.
The manned maneuvering unit flight controller arm
NASA Astrophysics Data System (ADS)
Falkner, K. E.
1983-05-01
The Manned Maneuvering Unit (MMU) and its support equipment provide an extravehicular astronaut mobility, and the ability to work outside the confines of the Shuttle Orbiter payload bay. The MMU design requirements are based on the highly successful Skylab M-509 maneuvering unit. Design of the MMU was started as an R&D effort in April 1975 and Flight Hardware design was started in August 1979 to support a possible requirement for in-space inspection and repair of Orbiter thermal protection tiles. Subsequently, the qualification test and production activities were slowed, and the current projected earliest first flight is now STS-11 in January, 1984. The MMU propulsion subsystem provides complete redundancy with two identical "system". Each system contains a high pressure gaseous nitrogen tank, an isolation valve, a regulator, and twelve 1.7 lbf (7.5 N) thrusters. The thrusters are packaged to provide the crew member six-degree-of-freedom control in response to commands from translational and rotational hand controllers. This paper discusses the MMU control arm requirements, design, and developmental history.
HESP: Instrument control, calibration and pipeline development
NASA Astrophysics Data System (ADS)
Anantha, Ch.; Roy, Jayashree; Mahesh, P. K.; Parihar, P. S.; Sangal, A. K.; Sriram, S.; Anand, M. N.; Anupama, G. C.; Giridhar, S.; Prabhu, T. P.; Sivarani, T.; Sundararajan, M. S.
Hanle Echelle SPectrograph (HESP) is a fibre-fed, high resolution (R = 30,000 and 60,000) spectrograph being developed for the 2m HCT telescope at IAO, Hanle. The major components of the instrument are a) Cassegrain unit b) Spectrometer instrument. An instrument control system interacting with a guiding unit at Cassegrain interface as well as handling spectrograph functions is being developed. An on-axis auto-guiding using the spill-over angular ring around the input pinhole is also being developed. The stellar light from the Cassegrain unit is taken to the spectrograph using an optical fiber which is being characterized for spectral transmission, focal ratio degradation and scrambling properties. The design of the thermal enclosure and thermal control for the spectrograph housing is presented. A data pipeline for the entire Echelle spectral reduction is being developed. We also plan to implement an instrument physical model based calibration into the main data pipeline and in the maintenance and quality control operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alvarez-Ramirez, J.; Aguilar, R.; Lopez-Isunza, F.
FCC processes involve complex interactive dynamics which are difficult to operate and control as well as poorly known reaction kinetics. This work concerns the synthesis of temperature controllers for FCC units. The problem is addressed first for the case where perfect knowledge of the reaction kinetics is assumed, leading to an input-output linearizing state feedback. However, in most industrial FCC units, perfect knowledge of reaction kinetics and composition measurements is not available. To address the problem of robustness against uncertainties in the reaction kinetics, an adaptive model-based nonlinear controller with simplified reaction models is presented. The adaptive strategy makes usemore » of estimates of uncertainties derived from calorimetric (energy) balances. The resulting controller is similar in form to standard input-output linearizing controllers and can be tuned analogously. Alternatively, the controller can be tuned using a single gain parameter and is computationally efficient. The performance of the closed-loop system and the controller design procedure are shown with simulations.« less
The conundrum of chemical boll weevil control in subtropical regions
USDA-ARS?s Scientific Manuscript database
The boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), is a tropical Mesoamerican insect that invaded the United States in 1893, spreading across the Cotton Belt as the key pest of cotton and causing billions of dollars in yield losses and insecticide-based control efforts;...
DeJournett, Jeremy; DeJournett, Leon
2017-11-01
Effective glucose control in the intensive care unit (ICU) setting has the potential to decrease morbidity and mortality rates and thereby decrease health care expenditures. To evaluate what constitutes effective glucose control, typically several metrics are reported, including time in range, time in mild and severe hypoglycemia, coefficient of variation, and others. To date, there is no one metric that combines all of these individual metrics to give a number indicative of overall performance. We proposed a composite metric that combines 5 commonly reported metrics, and we used this composite metric to compare 6 glucose controllers. We evaluated the following controllers: Ideal Medical Technologies (IMT) artificial-intelligence-based controller, Yale protocol, Glucommander, Wintergerst et al PID controller, GRIP, and NICE-SUGAR. We evaluated each controller across 80 simulated patients, 4 clinically relevant exogenous dextrose infusions, and one nonclinical infusion as a test of the controller's ability to handle difficult situations. This gave a total of 2400 5-day simulations, and 585 604 individual glucose values for analysis. We used a random walk sensor error model that gave a 10% MARD. For each controller, we calculated severe hypoglycemia (<40 mg/dL), mild hypoglycemia (40-69 mg/dL), normoglycemia (70-140 mg/dL), hyperglycemia (>140 mg/dL), and coefficient of variation (CV), as well as our novel controller metric. For the controllers tested, we achieved the following median values for our novel controller scoring metric: IMT: 88.1, YALE: 46.7, GLUC: 47.2, PID: 50, GRIP: 48.2, NICE: 46.4. The novel scoring metric employed in this study shows promise as a means for evaluating new and existing ICU-based glucose controllers, and it could be used in the future to compare results of glucose control studies in critical care. The IMT AI-based glucose controller demonstrated the most consistent performance results based on this new metric.
Dual-use micromechanical inertial sensors
NASA Astrophysics Data System (ADS)
Elwell, John M., Jr.
1995-03-01
A new industry, which will provide low-cost silicon-based inertial sensors to the commercial and military markets. is being created. Inertial measurement units are used extensively in military systems, and new versions are expected to find their way into commercial products, such as automobiles, as production costs fall as technology advances. An automotive inertial measurement unit can be expected to perform a complete range of control, diagnostic, and navigation functions. These functions are expected to provide significant active safety, performance, comfort, convenience, and fuel economy advantages to the automotive consumer. An inertial measurement unit applicable to the automobile industry would meet many of the performance requirements for the military in important areas, such as antenna and image stabilization, autopilot control, and the guidance of smart weapons. Such a new industrial base will significantly reduce the acquisition cost of many future tactical weapons systems. An alliance, consisting of the Charles Stark Draper Laboratory and Rockwell International, has been created to develop inertial products for this new industry.
78 FR 19416 - Revisions to Patent Term Adjustment
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-01
... designed to promote innovation; (8) considered approaches that reduce burdens and maintain flexibility and..., innovation, or the ability of United States-based enterprises to compete with foreign- based enterprises in... collection requirements associated with the information collections approved under OMB control number 0651...
Alternator control for battery charging
Brunstetter, Craig A.; Jaye, John R.; Tallarek, Glen E.; Adams, Joseph B.
2015-07-14
In accordance with an aspect of the present disclosure, an electrical system for an automotive vehicle has an electrical generating machine and a battery. A set point voltage, which sets an output voltage of the electrical generating machine, is set by an electronic control unit (ECU). The ECU selects one of a plurality of control modes for controlling the alternator based on an operating state of the vehicle as determined from vehicle operating parameters. The ECU selects a range for the set point voltage based on the selected control mode and then sets the set point voltage within the range based on feedback parameters for that control mode. In an aspect, the control modes include a trickle charge mode and battery charge current is the feedback parameter and the ECU controls the set point voltage within the range to maintain a predetermined battery charge current.
NASA Astrophysics Data System (ADS)
Wang, Xiaoliang; Chen, Daru; Li, Haitao; Wu, Qiong
2018-04-01
A novel method to artificially control the backscattering of the single-mode fiber (SMF) is proposed and investigated for the first time. This method can help to fabricate a high backscattering fiber (HBSF), such as by fabricating reflectors in every one meter interval of an SMF based on the exposure of the femtosecond laser beam. The artificially controlled backscattering (ACBS) can be much higher than the natural Rayleigh backscattering (RB) of the SMF. The RB power and ACBS power in the unit length fiber are derived according to the theory of the RBS. The total relative power and the relative back power reflected in the unit length of the HBSF have been simulated and presented. The simulated results show that the HBSF has the characteristics of both low optical attenuation and high backscattering. The relative back power reflected in the unit length of the HBSF is 25dB larger than the RB power of the SMF when the refractive index modulation quantity of the reflectors is 0.009. Some preliminary experiments also indicate that the method fabricating reflectors to increase the backscattering power of the SMF is practical and promising.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Gorman, T.; Gibson, K. J.; Snape, J. A.
2012-10-15
A real-time system has been developed to trigger both the MAST Thomson scattering (TS) system and the plasma control system on the phase and amplitude of neoclassical tearing modes (NTMs), extending the capabilities of the original system. This triggering system determines the phase and amplitude of a given NTM using magnetic coils at different toroidal locations. Real-time processing of the raw magnetic data occurs on a low cost field programmable gate array (FPGA) based unit which permits triggering of the TS lasers on specific amplitudes and phases of NTM evolution. The MAST plasma control system can receive a separate triggermore » from the FPGA unit that initiates a vertical shift of the MAST magnetic axis. Such shifts have fully removed m/n= 2/1 NTMs instabilities on a number of MAST discharges.« less
Design and optimize of 3-axis filament winding machine
NASA Astrophysics Data System (ADS)
Quanjin, Ma; Rejab, M. R. M.; Idris, M. S.; Bachtiar, B.; Siregar, J. P.; Harith, M. N.
2017-10-01
Filament winding technique is developed as the primary process for composite cylindrical structures fabrication at low cost. Fibres are wound on a rotating mandrel by a filament winding machine where resin impregnated fibres pass through a pay-out eye. This paper aims to develop and optimize a 3-axis, lightweight, practical, efficient, portable filament winding machine to satisfy the customer demand, which can fabricate pipes and round shape cylinders with resins. There are 3 main units on the 3-axis filament winding machine, which are the rotary unit, the delivery unit and control system unit. Comparison with previous existing filament winding machines in the factory, it has 3 degrees of freedom and can fabricate more complex shape specimens based on the mandrel shape and particular control system. The machine has been designed and fabricated on 3 axes movements with control system. The x-axis is for movement of the carriage, the y-axis is the rotation of mandrel and the z-axis is the movement of the pay-out eye. Cylindrical specimens with different dimensions and winding angles were produced. 3-axis automated filament winding machine has been successfully designed with simple control system.
Snaring to control feral pigs sus scrofa in a remote Hawaiian rain forest
Anderson, Stephen J.; Stone, Charles P.
1993-01-01
Feral pig Sus scrofa control in Kipahulu Valley, a remote rain forest in Haleakala National Park, Maui, Hawaiian Islands, has been achieved with snares over a 45-month period. Initial pig densities in fenced management units of 6·2 km2 and 7·8 km2were estimated at 6 animals/km2 and 14·3 animals/km2 for the two units, based on population reconstruction from animals killed and aged. During the 45 months of the study, 1978 snares were set, and 1·6 million snare nights were logged. Snare density reached 96/km2 and 200/km2 for the two management units by the end of the study. A mean effort of 43 worker hours/pig was used to remove 53 pigs from the upper management unit, and a mean of 7 worker hours/pig to remove 175 animals from the more densely populated lower unit. Pig activity monitoring along transects provided a good measure of control effectiveness until densities of about 1 pig/km2 were achieved, after which transects became less useful than scouting for determining pig activity.
NASA Astrophysics Data System (ADS)
Venkataramanan, Arjun; Rios Perez, Carlos A.; Hidrovo, Carlos H.
2016-11-01
Electric vehicles (EVs) are the future of clean transportation and driving range is one of the important parameters which dictates its marketability. In order to increase driving range, electrical battery energy consumption should be minimized. Vapor-compression refrigeration systems currently employed in EVs for climate control consume a significant fraction of the battery charge. Thus, by replacing this traditional heating ventilation and air-conditioning system with an adsorption based climate control system one can have the capability of increasing the drive range of EVs.The Advanced Thermo-adsorptive Battery (ATB) for climate control is a water-based adsorption type refrigeration cycle. An essential component of the ATB is a low pressure evaporator/condenser unit (ECU) which facilitates both the evaporation and condensation processes. The thermal design of the ECU relies predominantly on the accurate prediction of evaporation/boiling heat transfer coefficients since the standard correlations for predicting boiling heat transfer coefficients have large uncertainty at the low operating pressures of the ATB. This work describes the design and development of a low pressure ECU as well as the thermal performance of the actual ECU prototype.
A wall-free climate unit for acoustic levitators.
Schlegel, M C; Wenzel, K-J; Sarfraz, A; Panne, U; Emmerling, F
2012-05-01
Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses.
A wall-free climate unit for acoustic levitators
NASA Astrophysics Data System (ADS)
Schlegel, M. C.; Wenzel, K.-J.; Sarfraz, A.; Panne, U.; Emmerling, F.
2012-05-01
Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses.
98. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), ...
98. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770). POWER DISTRIBUTION UNITS AND CABLE DISTRIBUTION UNITS IN EAST ROW OF CABINETS; LOGIC CONTROL AND MONITOR UNITS FOR BOOSTER AND FUEL SYSTEMS, AND SIGNAL CONDITIONERS IN WEST ROW OF CABINETS. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT THE SOUTH END OF LANDLINE INSTRUMENTATION ROOM (106). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Are Droughts in the United States Great Plains Predictable on Seasonal and Longer Time Scales?
NASA Technical Reports Server (NTRS)
Schubert, Siegfried D.; Suarez, M.; Pegion, P.; Kistler, M.; Einaudi, Franco (Technical Monitor)
2001-01-01
The United States Great Plains has experienced numerous episodes of unusually dry conditions lasting anywhere from months to several years, In this presentation, we will examine the predictability of such episodes and the physical mechanisms controlling the variability of the summer climate of the continental United States. The analysis is based on ensembles of multi-year simulations and seasonal hindcasts generated with the NASA Seasonal to-Interannual Prediction Project (NSIPP-1) General Circulation Model.
Petersen, Mark D.; Zeng, Yuehua; Haller, Kathleen M.; McCaffrey, Robert; Hammond, William C.; Bird, Peter; Moschetti, Morgan; Shen, Zhengkang; Bormann, Jayne; Thatcher, Wayne
2014-01-01
The 2014 National Seismic Hazard Maps for the conterminous United States incorporate additional uncertainty in fault slip-rate parameter that controls the earthquake-activity rates than was applied in previous versions of the hazard maps. This additional uncertainty is accounted for by new geodesy- and geology-based slip-rate models for the Western United States. Models that were considered include an updated geologic model based on expert opinion and four combined inversion models informed by both geologic and geodetic input. The two block models considered indicate significantly higher slip rates than the expert opinion and the two fault-based combined inversion models. For the hazard maps, we apply 20 percent weight with equal weighting for the two fault-based models. Off-fault geodetic-based models were not considered in this version of the maps. Resulting changes to the hazard maps are generally less than 0.05 g (acceleration of gravity). Future research will improve the maps and interpret differences between the new models.
Leib, Kenneth J.; Bauch, Nancy J.
2008-01-01
In 1974, the Colorado River Basin Salinity Control Act was passed into law. This law was enacted to address concerns regarding the salinity content of the Colorado River. The law authorized various construction projects in selected areas or 'units' of the Colorado River Basin intended to reduce the salinity load in the Colorado River. One such area was the Grand Valley Salinity Control Unit in western Colorado. The U. S. Geological Survey has done extensive studies and research in the Grand Valley Salinity Control Unit that provide information to aid the U.S. Bureau of Reclamation and the Natural Resources Conservation Service in determining where salinity-control work may provide the best results, and to what extent salinity-control work was effective in reducing salinity concentrations and loads in the Colorado River. Previous studies have indicated that salinity concentrations and loads have been decreasing downstream from the Grand Valley Salinity Control Unit, and that the decreases are likely the result of salinity control work in these areas. Several of these reports; however, also document decreasing salinity loads upstream from the Grand Valley Salinity Control Unit. This finding was important because only a small amount of salinity-control work was being done in areas upstream from the Grand Valley Salinity Control Unit at the time the findings were reported (late 1990?s). As a result of those previous findings, the U.S. Bureau of Reclamation entered into a cooperative agreement with the U.S. Geological Survey to investigate salinity trends in selected areas bracketing the Grand Valley Salinity Control Unit and regions upstream from the Grand Valley Salinity Control Unit. The results of the study indicate that salinity loads were decreasing upstream from the Grand Valley Salinity Control Unit from 1986 through 2003, but the rates of decrease have slowed during the last 10 years. The average rate of decrease in salinity load upstream from the Grand Valley Salinity Control Unit was 10,700 tons/year. This accounts for approximately 27 percent of the decrease observed downstream from the Grand Valley Salinity Control Unit. Salinity loads were decreasing at the fastest rate (6,950 tons/year) in Region 4, which drains an area between the Colorado River at Cameo, Colorado (station CAMEO) and Colorado River above Glenwood Springs, Colorado (station GLEN) streamflow-gaging stations. Trends in salinity concentration and streamflow were tested at station CAMEO to determine if salinity concentration, streamflow, or both are controlling salinity loads upstream from the Grand Valley Salinity Control Unit. Trend tests of individual ion concentrations were included as potential indicators of what sources (based on mineral composition) may be controlling trends in the upper Colorado. No significant trend was detected for streamflow from 1986 to 2003 at station CAMEO; however, a significant downward trend was detected for salinity concentration. The trend slope indicates that salinity concentration is decreasing at a median rate of about 3.54 milligrams per liter per year. Five major ions (calcium, magnesium, sodium, sulfate, and chloride) were tested for trends. The results indicate that processes within source areas with rock and soil types (or other unidentified sources) bearing calcium, sodium, and sulfate had the largest effect on the downward trend in salinity load upstream from station CAMEO. Downward trends in salinity load resulting from ground-water sources and/or land-use change were thought to be possible reasons for the observed decreases in salinity loads; however, the cause or causes of the decreasing salinity loads are not fully understood. A reduction in the amount of ground-water percolation from Region 4 (resulting from work done through Federal irrigation system improvement programs as well as privately funded irrigation system improvements) has helped reduce annual salinity load from Region 4 by approxima
Applying the Theory of Constraints to a Base Civil Engineering Operations Branch
1991-09-01
Figure Page 1. Typical Work Order Processing . .......... 7 2. Typical Job Order Processing . .......... 8 3. Typical Simplified In-Service Work Plan for...Customers’ Customer Request Service Planning Unit Production] Control Center Material Control Scheduling CE Shops Figure 1.. Typical Work Order Processing 7
77 FR 19015 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-29
... Disease Control and Prevention (CDC). Background and Brief Description Colorectal Cancer (CRC) is the second leading cause of cancer- related deaths in the United States, following lung cancer. Based on... days of this notice. Proposed Project Colorectal Cancer Control Program Indirect/Non-Medical Cost Study...
1991-01-01
vrify tht noise levels and pemitted hours of (Control of PoIlution Act opeation specified in notice me being comlied with (if aplicable ). 1974, Part IIJ...cover - -poperi . - condition of cdin -- toilet - health and amfe - mobile Plant - -delm a ge - -tow chaii - tip records - leacliate control (1) Base
ERIC Educational Resources Information Center
Henderson, William Edward, Jr., Ed.
This articulation guide contains 17 units of instruction for the first year of a two-year vocational program designed to prepare the high school graduate to install, maintain, and repair various types of residential and commercial heating, air conditioning, and refrigeration equipment. The units are to introduce the student to fundamental theories…
Distributed and recoverable digital control system
NASA Technical Reports Server (NTRS)
Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)
2010-01-01
A real-time multi-tasking digital control system with rapid recovery capability is disclosed. The control system includes a plurality of computing units comprising a plurality of redundant processing units, with each of the processing units configured to generate one or more redundant control commands. One or more internal monitors are employed for detecting data errors in the control commands. One or more recovery triggers are provided for initiating rapid recovery of a processing unit if data errors are detected. The control system also includes a plurality of actuator control units each in operative communication with the computing units. The actuator control units are configured to initiate a rapid recovery if data errors are detected in one or more of the processing units. A plurality of smart actuators communicates with the actuator control units, and a plurality of redundant sensors communicates with the computing units.
NASA Astrophysics Data System (ADS)
Figl, Michael; Birkfellner, Wolfgang; Watzinger, Franz; Wanschitz, Felix; Hummel, Johann; Hanel, Rudolf A.; Ewers, Rolf; Bergmann, Helmar
2002-05-01
Two main concepts of Head Mounted Displays (HMD) for augmented reality (AR) visualization exist, the optical and video-see through type. Several research groups have pursued both approaches for utilizing HMDs for computer aided surgery. While the hardware requirements for a video see through HMD to achieve acceptable time delay and frame rate seem to be enormous the clinical acceptance of such a device is doubtful from a practical point of view. Starting from previous work in displaying additional computer-generated graphics in operating microscopes, we have adapted a miniature head mounted operating microscope for AR by integrating two very small computer displays. To calibrate the projection parameters of this so called Varioscope AR we have used Tsai's Algorithm for camera calibration. Connection to a surgical navigation system was performed by defining an open interface to the control unit of the Varioscope AR. The control unit consists of a standard PC with a dual head graphics adapter to render and display the desired augmentation of the scene. We connected this control unit to a computer aided surgery (CAS) system by the TCP/IP interface. In this paper we present the control unit for the HMD and its software design. We tested two different optical tracking systems, the Flashpoint (Image Guided Technologies, Boulder, CO), which provided about 10 frames per second, and the Polaris (Northern Digital, Ontario, Canada) which provided at least 30 frames per second, both with a time delay of one frame.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouaichaoui, Youcef; Berrahal, Abderezak; Halbaoui, Khaled
This paper describes the design of data acquisition system (DAQ) that is connected to a PC and development of a feedback control system that maintains the coolant temperature of the process at a desired set point using a digital controller system based on the graphical programming language. The paper will provide details about the data acquisition unit, shows the implementation of the controller, and present test results. (authors)
A.S. Ward; M. Fitzgerald; M.N. Gooseff; A.M. Binley; K. Singha
2012-01-01
Hyporheic hydrodynamics are a control on stream ecosystems, yet we lack a thorough understanding of catchment controls on these flow paths, including valley constraint and hydraulic gradients in the valley bottom. We performed four whole-stream solute tracer injections under steady state flow conditions at the H. J. Andrews Experimental Forest (Oregon, United States)...
A COTS-Based Replacement Strategy for Aging Avionics Computers
2001-12-01
Communication Control Unit. A COTS-Based Replacement Strategy for Aging Avionics Computers COTS Microprocessor Real Time Operating System New Native Code...Native Code Objec ts Native Code Thread Real - Time Operating System Legacy Function x Virtual Component Environment Context Switch Thunk Add-in Replace
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This decision document presents the amended remedial action for Operable Units 3, 4, and 5 (OUs 3, 4, and 5) at Eielson Air Force Base (AFB). This decision is based on the Administrative Record for OU 3, 4, and 5, updated in July 1998, to include new information generated since the original Record of Decision was signed on 30 September 1995 (PB95-964618). This amendment applies to OU3 site DP44 (Battery Shop Leach Field Building), OU4 sites SS35 (Asphalt Mixing Area) and ST58 (Old Quartermaster Service Station), and OU5 sites LF03/FT09 (Current Inactive Base Landfill/Fire Training Area). Through new information, contaminantmore » levels than interpreted prior to signing the original ROD document. Proper enforcement of Institutional Controls (IC`s) at all sites will be effective in controlling and restricting access to contaminated media at the sites remediation goals are achieved.« less
Joint Forward Operating Base Elements of Command and Control
NASA Astrophysics Data System (ADS)
Summers, William C.
2002-01-01
Since the 1986 Goldwater-Nichols Act directed the Chairman of the Joint Chiefs of Staff to develop doctrine for the joint employment of the armed forces, tactics, techniques, and procedures have evolved at different rates depending on the competency. Whereas the command of joint air forces is well prescribed within the structure of the air operations center and its associated leadership, command of air assets at a joint forward operating base lacks guidance. Today, the United States prosecutes an air war over Afghanistan from bases in Uzbekistan, Pakistan, and Afghanistan. Elements of the United States Army, Air Force, and Marines combine at these geographically minute locations, each bringing a certain complement of support and command and control. Evidence from operations during the 1999 air war for Kosovo at Tirana Rinas Airport in Albania suggests that when these service elements meet at the airfield for the first time, there are problems associated with local procedure. At best, time is wasted creating local joint systems to overcome the difficulties. At worst, safety and mission accomplishment are jeopardized. This thesis will address the need to develop doctrine and a jointly integrated organization to support the command and control function at a forward operating base.
Kerr, Robert R; Grayden, David B; Thomas, Doreen A; Gilson, Matthieu; Burkitt, Anthony N
2014-01-01
The brain is able to flexibly select behaviors that adapt to both its environment and its present goals. This cognitive control is understood to occur within the hierarchy of the cortex and relies strongly on the prefrontal and premotor cortices, which sit at the top of this hierarchy. Pyramidal neurons, the principal neurons in the cortex, have been observed to exhibit much stronger responses when they receive inputs at their soma/basal dendrites that are coincident with inputs at their apical dendrites. This corresponds to inputs from both lower-order regions (feedforward) and higher-order regions (feedback), respectively. In addition to this, coherence between oscillations, such as gamma oscillations, in different neuronal groups has been proposed to modulate and route communication in the brain. In this paper, we develop a simple, but novel, neural mass model in which cortical units (or ensembles) exhibit gamma oscillations when they receive coherent oscillatory inputs from both feedforward and feedback connections. By forming these units into circuits that can perform logic operations, we identify the different ways in which operations can be initiated and manipulated by top-down feedback. We demonstrate that more sophisticated and flexible top-down control is possible when the gain of units is modulated by not only top-down feedback but by coherence between the activities of the oscillating units. With these types of units, it is possible to not only add units to, or remove units from, a higher-level unit's logic operation using top-down feedback, but also to modify the type of role that a unit plays in the operation. Finally, we explore how different network properties affect top-down control and processing in large networks. Based on this, we make predictions about the likely connectivities between certain brain regions that have been experimentally observed to be involved in goal-directed behavior and top-down attention.
Kerr, Robert R.; Grayden, David B.; Thomas, Doreen A.; Gilson, Matthieu; Burkitt, Anthony N.
2014-01-01
The brain is able to flexibly select behaviors that adapt to both its environment and its present goals. This cognitive control is understood to occur within the hierarchy of the cortex and relies strongly on the prefrontal and premotor cortices, which sit at the top of this hierarchy. Pyramidal neurons, the principal neurons in the cortex, have been observed to exhibit much stronger responses when they receive inputs at their soma/basal dendrites that are coincident with inputs at their apical dendrites. This corresponds to inputs from both lower-order regions (feedforward) and higher-order regions (feedback), respectively. In addition to this, coherence between oscillations, such as gamma oscillations, in different neuronal groups has been proposed to modulate and route communication in the brain. In this paper, we develop a simple, but novel, neural mass model in which cortical units (or ensembles) exhibit gamma oscillations when they receive coherent oscillatory inputs from both feedforward and feedback connections. By forming these units into circuits that can perform logic operations, we identify the different ways in which operations can be initiated and manipulated by top-down feedback. We demonstrate that more sophisticated and flexible top-down control is possible when the gain of units is modulated by not only top-down feedback but by coherence between the activities of the oscillating units. With these types of units, it is possible to not only add units to, or remove units from, a higher-level unit's logic operation using top-down feedback, but also to modify the type of role that a unit plays in the operation. Finally, we explore how different network properties affect top-down control and processing in large networks. Based on this, we make predictions about the likely connectivities between certain brain regions that have been experimentally observed to be involved in goal-directed behavior and top-down attention. PMID:25152715
O'Shea, Eamon; Devane, Declan; Murphy, Kathy; Cooney, Adeline; Casey, Dympna; Jordan, Fionnuala; Hunter, Andrew; Murphy, Edel
2011-02-14
Current projections indicate that there will be a significant increase in the number of people with dementia in Ireland, from approximately 40,000 at present to 100,000 by 2036. Psychosocial interventions, such as reminiscence, have the potential to improve the quality of life of people with dementia. However, while reminiscence is used widely in dementia care, its impact on the quality of life of people with dementia remains largely undocumented and there is a need for a robust and fair assessment of its overall effectiveness. The DementiA education programme incorporating REminiscence for Staff study will evaluate the effectiveness of a structured reminiscence-based education programme for care staff on the quality of life of residents with dementia in long-stay units. The study is a two-group, single-blind cluster randomised trial conducted in public and private long-stay residential settings in Ireland. Randomisation to control and intervention is at the level of the long-stay residential unit. Sample size calculations suggest that 18 residential units each containing 17 people with dementia are required for randomisation to control and intervention groups to achieve power of at least 80% with alpha levels of 0.05. Each resident in the intervention group is linked with a nurse and care assistant who have taken the structured reminiscence-based education programme. Participants in the control group will receive usual care. The primary outcome is quality of life of residents as measured by the Quality of Life-AD instrument. Secondary outcomes include agitation, depression and carer burden. Blinded outcome assessment is undertaken at baseline and at 18-22 weeks post-randomisation. Trials on reminiscence-based interventions for people with dementia have been scarce and the quality of the information arising from those that have been done has been undermined by methodological problems, particularly in relation to scale and scope. This trial is powered to deliver more credible and durable results. The trial may also convey process utility to a long-stay system in Ireland that has not been geared for education and training, especially in relation to dementia. The results of this trial are applicable to long-stay residential units in Ireland and internationally. Current Controlled Trials ISRCTN99651465.
Development of a front end controller/heap manager for PHENIX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ericson, M.N.; Allen, M.D.; Musrock, M.S.
1996-12-31
A controller/heap manager has been designed for applicability to all detector subsystem types of PHENIX. the heap manager performs all functions associated with front end electronics control including ADC and analog memory control, data collection, command interpretation and execution, and data packet forming and communication. Interfaces to the unit consist of a timing and control bus, a serial bus, a parallel data bus, and a trigger interface. The topology developed is modular so that many functional blocks are identical for a number of subsystem types. Programmability is maximized through the use of flexible modular functions and implementation using field programmablemore » gate arrays (FPGAs). Details of unit design and functionality will be discussed with particular detail given to subsystems having analog memory-based front end electronics. In addition, mode control, serial functions, and FPGA implementation details will be presented.« less
Test Program of the "Combined Data and Power Management Infrastructure"
NASA Astrophysics Data System (ADS)
Eickhoff, Jens; Fritz, Michael; Witt, Rouven; Bucher, Nico; Roser, Hans-Peter
2013-08-01
As already published in previous DASIA papers, the University of Stuttgart, Germany, is developing an advanced 3-axis stabilized small satellite applying industry standards for command/control techniques and Onboard Software design. This satellite furthermore features an innovative hybrid architecture of Onboard Computer and Power Control and Distribution Unit. One of the main challenges was the development of an ultra-compact and performing Onboard Computer (OBC), which was intended to support an RTEMS operating system, a PUS standard based Onboard Software (OBSW) and CCSDS standard based ground/space communication. The developed architecture (see [1, 2, 3]) is called a “Combined Onboard Data and Power Management Infrastructure” - CDPI. It features: The OBC processor boards based on a LEON3FT architecture - from Aeroflex Inc., USA The I/O Boards for all OBC digital interfaces to S/C equipment (digital RIU) - from 4Links Ltd. UK CCSDS TC/TM decoder/encoder boards - with same HW design as I/O boards - just with limited number of interfaces. HW from 4Links Ltd, UK, driver SW and IP-Core from Aeroflex Gaisler, SE Analog RIU functions via enhanced PCDU from Vectronic Aerospace, D OBC reconfiguration unit functions via Common Controller - here in PCDU [4] The CDPI overall assembly is meanwhile complete and a exhaustive description can be found in [5]. The EM test campaign including the HW/SW compatibility testing is finalized. This comprises all OBC EM units, OBC EM assembly and the EM PCDU. The unit test program for the FM Processor-Boards and Power-Boards of the OBC are completed and the unit tests of FM I/O-Boards and CCSDS-Boards have been completed by 4Links at the assembly house. The subsystem tests of the assembled OBC also are completed and the overall System tests of the CDPI with system reconfiguration in diverse possible FDIR cases also reach the last steps. Still ongoing is the subsequent integration of the CDPI with the satellite's avionics components encompassing TTC, AOCS, Power and Payload Control. This paper provides a full picture of the test campaign. Further details can be taken from
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2013 CFR
2013-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2012 CFR
2012-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2011 CFR
2011-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2014 CFR
2014-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
RTU Comparison Calculator Enhancement Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, James D.; Wang, Weimin; Katipamula, Srinivas
Over the past two years, Department of Energy’s Building Technologies Office (BTO) has been investigating ways to increase the operating efficiency of the packaged rooftop units (RTUs) in the field. First, by issuing a challenge to the RTU manufactures to increase the integrated energy efficiency ratio (IEER) by 60% over the existing ASHRAE 90.1-2010 standard. Second, by evaluating the performance of an advanced RTU controller that reduces the energy consumption by over 40%. BTO has previously also funded development of a RTU comparison calculator (RTUCC). RTUCC is a web-based tool that provides the user a way to compare energy andmore » cost savings for two units with different efficiencies. However, the RTUCC currently cannot compare savings associated with either the RTU Challenge unit or the advanced RTU controls retrofit. Therefore, BTO has asked PNNL to enhance the tool so building owners can compare energy and savings associated with this new class of products. This document provides the details of the enhancements that are required to support estimating energy savings from use of RTU challenge units or advanced controls on existing RTUs.« less
Initial closed operation of the CELSS Test Facility Engineering Development Unit
NASA Technical Reports Server (NTRS)
Kliss, M.; Blackwell, C.; Zografos, A.; Drews, M.; MacElroy, R.; McKenna, R.; Heyenga, A. G.
2003-01-01
As part of the NASA Advanced Life Support Flight Program, a Controlled Ecological Life Support System (CELSS) Test Facility Engineering Development Unit has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The Engineering Development Unit (EDU) is a tightly closed, stringently controlled, ground-based testbed which provides a broad range of environmental conditions under which a variety of CELSS higher plant crops can be grown. Although the EDU was developed primarily to provide near-term engineering data and a realistic determination of the subsystem and system requirements necessary for the fabrication of a comparable flight unit, the EDU has also provided a means to evaluate plant crop productivity and physiology under controlled conditions. This paper describes the initial closed operational testing of the EDU, with emphasis on the hardware performance capabilities. Measured performance data during a 28-day closed operation period are compared with the specified functional requirements, and an example of inferring crop growth parameters from the test data is presented. Plans for future science and technology testing are also discussed. Published by Elsevier Science Ltd on behalf of COSPAR.
Challenges for the Baltic Sea Regional Stability
2013-03-01
statements show that Russia still has ambitions to expand her influence and control over the Baltic Sea region. Reduction of U.S. military presence in Europe...combat support units during 2013-2015, such as A-10 squadron at Spangdahlem Air Base in Germany, the 603rd Air Control Squadron at Aviano Air Base in ...other hand, such continued cooperation in the period of defense austerity would be the main option for sharing and reaching cost effectiveness
NASA Astrophysics Data System (ADS)
Abou-Elnour, Ali; Thabt, A.; Helmy, S.; Kashf, Y.; Hadad, Y.; Tarique, M.; Abo-Elnor, Ossama
2014-04-01
In the present work, wireless sensor network and smart real-time controlling and monitoring system are integrated for efficient energy management of standalone photovoltaic system. The proposed system has two main components namely the monitoring and controlling system and the wireless communication system. LabView software has been used in the implementation of the monitoring and controlling system. On the other hand, ZigBee wireless modules have been used to implement the wireless system. The main functions of monitoring and controlling unit is to efficiently control the energy consumption form the photovoltaic system based on accurate determination of the periods of times at which the loads are required to be operated. The wireless communication system send the data from the monitoring and controlling unit to the loads at which desired switching operations are performed. The wireless communication system also continuously feeds the monitoring and controlling unit with updated input data from the sensors and from the photovoltaic module send to calculate and record the generated, the consumed, and the stored energy to apply load switching saving schemes if necessary. It has to be mentioned that our proposed system is a low cost and low power system because and it is flexible to be upgraded to fulfill additional users' requirements.
Design of MPPT Controller Monitoring Software Based on QT Framework
NASA Astrophysics Data System (ADS)
Meng, X. Z.; Lu, P. G.
2017-10-01
The MPPT controller was a hardware device for tracking the maximum power point of solar photovoltaic array. Multiple controllers could be working as networking mode by specific communicating protocol. In this article, based on C++ GUI programming with Qt frame, we designed one sort of desktop application for monitoring and analyzing operational parameter of MPPT controller. The type of communicating protocol for building network was Modbus protocol which using Remote Terminal Unit mode and The desktop application of host computer was connected with all the controllers in the network through RS485 communication or ZigBee wireless communication. Using this application, user could monitor the parameter of controller wherever they were by internet.
Kang, Junsu; Lee, Donghyeon; Heo, Young Jin; Chung, Wan Kyun
2017-11-07
For highly-integrated microfluidic systems, an actuation system is necessary to control the flow; however, the bulk of actuation devices including pumps or valves has impeded the broad application of integrated microfluidic systems. Here, we suggest a microfluidic process control method based on built-in microfluidic circuits. The circuit is composed of a fluidic timer circuit and a pneumatic logic circuit. The fluidic timer circuit is a serial connection of modularized timer units, which sequentially pass high pressure to the pneumatic logic circuit. The pneumatic logic circuit is a NOR gate array designed to control the liquid-controlling process. By using the timer circuit as a built-in signal generator, multi-step processes could be done totally inside the microchip without any external controller. The timer circuit uses only two valves per unit, and the number of process steps can be extended without limitation by adding timer units. As a demonstration, an automation chip has been designed for a six-step droplet treatment, which entails 1) loading, 2) separation, 3) reagent injection, 4) incubation, 5) clearing and 6) unloading. Each process was successfully performed for a pre-defined step-time without any external control device.
Silva, A F; Sarraguça, M C; Fonteyne, M; Vercruysse, J; De Leersnyder, F; Vanhoorne, V; Bostijn, N; Verstraeten, M; Vervaet, C; Remon, J P; De Beer, T; Lopes, J A
2017-08-07
A multivariate statistical process control (MSPC) strategy was developed for the monitoring of the ConsiGma™-25 continuous tablet manufacturing line. Thirty-five logged variables encompassing three major units, being a twin screw high shear granulator, a fluid bed dryer and a product control unit, were used to monitor the process. The MSPC strategy was based on principal component analysis of data acquired under normal operating conditions using a series of four process runs. Runs with imposed disturbances in the dryer air flow and temperature, in the granulator barrel temperature, speed and liquid mass flow and in the powder dosing unit mass flow were utilized to evaluate the model's monitoring performance. The impact of the imposed deviations to the process continuity was also evaluated using Hotelling's T 2 and Q residuals statistics control charts. The influence of the individual process variables was assessed by analyzing contribution plots at specific time points. Results show that the imposed disturbances were all detected in both control charts. Overall, the MSPC strategy was successfully developed and applied. Additionally, deviations not associated with the imposed changes were detected, mainly in the granulator barrel temperature control. Copyright © 2017 Elsevier B.V. All rights reserved.
A monitoring system based on electric vehicle three-stage wireless charging
NASA Astrophysics Data System (ADS)
Hei, T.; Liu, Z. Z.; Yang, Y.; Hongxing, CHEN; Zhou, B.; Zeng, H.
2016-08-01
An monitoring system for three-stage wireless charging was designed. The vehicle terminal contained the core board which was used for battery information collection and charging control and the power measurement and charging control core board was provided at the transmitting terminal which communicated with receiver by Bluetooth. A touch-screen display unit was designed based on MCGS (Monitor and Control Generated System) to simulate charging behavior and to debug the system conveniently. The practical application shown that the system could be stable and reliable, and had a favorable application foreground.
Zarb, P; Coignard, B; Griskeviciene, J; Muller, A; Vankerckhoven, V; Weist, K; Goossens, Mm; Vaerenberg, S; Hopkins, S; Catry, B; Monnet, Dl; Goossens, H; Suetens, C
2012-11-15
A standardised methodology for a combined point prevalence survey (PPS) on healthcare-associated infections (HAIs) and antimicrobial use in European acute care hospitals developed by the European Centre for Disease Prevention and Control was piloted across Europe. Variables were collected at national, hospital and patient level in 66 hospitals from 23 countries. A patient-based and a unit-based protocol were available. Feasibility was assessed via national and hospital questionnaires. Of 19,888 surveyed patients, 7.1% had an HAI and 34.6% were receiving at least one antimicrobial agent. Prevalence results were highest in intensive care units, with 28.1% patients with HAI, and 61.4% patients with antimicrobial use. Pneumonia and other lower respiratory tract infections (2.0% of patients; 95% confidence interval (CI): 1.8–2.2%) represented the most common type (25.7%) of HAI. Surgical prophylaxis was the indication for 17.3% of used antimicrobials and exceeded one day in 60.7% of cases. Risk factors in the patient-based protocol were provided for 98% or more of the included patients and all were independently associated with both presence of HAI and receiving an antimicrobial agent. The patient-based protocol required more work than the unit-based protocol, but allowed collecting detailed data and analysis of risk factors for HAI and antimicrobial use.
Anthropometric considerations for a 4-axis side-arm flight controller
NASA Technical Reports Server (NTRS)
Debellis, W. B.
1986-01-01
A data base on multiaxis side-arm flight controls was generated. The rapid advances in fly-by-light technology, automatic stability systems, and onboard computers have combined to create flexible flight control systems which could reduce the workload imposed on the operator by complex new equipment. This side-arm flight controller combines four controls into one unit and should simplify the pilot's task. However, the use of a multiaxis side-arm flight controller without complete cockpit integration may tend to increase the pilot's workload.
NASA Astrophysics Data System (ADS)
Di Giorgio, Anna Maria; Biondi, David; Saggin, Bortolino; Shatalina, Irina; Viterbini, Maurizio; Giusi, Giovanni; Liu, Scige J.; Cerulli-Irelli, Paquale; Van Loon, Dennis; Cara, Christophe
2012-09-01
We present the preliminary design of the Instrument Control Unit (ICU) of the SpicA FAR infrared Instrument (SAFARI), an imaging Fourier Transform Spectrometer (FTS) designed to give continuous wavelength coverage in both photometric and spectroscopic modes from around 34 to 210 µm. Due to the stringent requirements in terms of mass and volume, the overall SAFARI warm electronics will be composed by only two main units: Detector Control Unit and ICU. ICU is therefore a macro-unit incorporating the four digital sub-units dedicated to the control of the overall instrument functionalities: the Cooler Control Unit, the Mechanism Control Unit, the Digital processing Unit and the Power Supply Unit. Both the mechanical solution adopted to host the four sub-units and the internal electrical architecture are presented as well as the adopted redundancy approach.
Application of a microcomputer-based system to control and monitor bacterial growth.
Titus, J A; Luli, G W; Dekleva, M L; Strohl, W R
1984-02-01
A modular microcomputer-based system was developed to control and monitor various modes of bacterial growth. The control system was composed of an Apple II Plus microcomputer with 64-kilobyte random-access memory; a Cyborg ISAAC model 91A multichannel analog-to-digital and digital-to-analog converter; paired MRR-1 pH, pO(2), and foam control units; and in-house-designed relay, servo control, and turbidimetry systems. To demonstrate the flexibility of the system, we grew bacteria under various computer-controlled and monitored modes of growth, including batch, turbidostat, and chemostat systems. The Apple-ISAAC system was programmed in Labsoft BASIC (extended Applesoft) with an average control program using ca. 6 to 8 kilobytes of memory and up to 30 kilobytes for datum arrays. This modular microcomputer-based control system was easily coupled to laboratory scale fermentors for a variety of fermentations.
Application of a Microcomputer-Based System to Control and Monitor Bacterial Growth
Titus, Jeffrey A.; Luli, Gregory W.; Dekleva, Michael L.; Strohl, William R.
1984-01-01
A modular microcomputer-based system was developed to control and monitor various modes of bacterial growth. The control system was composed of an Apple II Plus microcomputer with 64-kilobyte random-access memory; a Cyborg ISAAC model 91A multichannel analog-to-digital and digital-to-analog converter; paired MRR-1 pH, pO2, and foam control units; and in-house-designed relay, servo control, and turbidimetry systems. To demonstrate the flexibility of the system, we grew bacteria under various computer-controlled and monitored modes of growth, including batch, turbidostat, and chemostat systems. The Apple-ISAAC system was programmed in Labsoft BASIC (extended Applesoft) with an average control program using ca. 6 to 8 kilobytes of memory and up to 30 kilobytes for datum arrays. This modular microcomputer-based control system was easily coupled to laboratory scale fermentors for a variety of fermentations. PMID:16346462
[Design of the image browser for PACS image workstation].
Li, Feng; Zhou, He-Qin
2006-09-01
The design of PACS image workstation based on DICOM3.0 is introduced in the paper, then the designing method of the PACS image browser based on the control system theory is presented,focusing on two main units:DICOM analyzer and the information mapping transformer.
NASA Technical Reports Server (NTRS)
Clinedinst, Winston C.; Debure, Kelly R.; Dickson, Richard W.; Heaphy, William J.; Parks, Mark A.; Slominski, Christopher J.; Wolverton, David A.
1988-01-01
The Flight Management/Flight Controls (FM/FC) software for the Norden 2 (PDP-11/70M) computer installed on the NASA 737 aircraft is described. The software computes the navigation position estimates, guidance commands, those commands to be issued to the control surfaces to direct the aircraft in flight based on the modes selected on the Advanced Guidance Control System (AGSC) mode panel, and the flight path selected via the Navigation Control/Display Unit (NCDU).
Sampling and Control Circuit Board for an Inertial Measurement Unit
NASA Technical Reports Server (NTRS)
Chelmins, David T (Inventor); Sands, Obed (Inventor); Powis, Richard T., Jr. (Inventor)
2016-01-01
A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.
Abdelwahab, Hisham; Shigidi, Mazin; El-Tohami, Alyaa; Ibrahim, Lamees
2013-05-01
Hemodialysis (HD) is a complex procedure with many specifications and requires adherence to a set of particular clinical practice guidelines. These guidelines had already been established by globally acclaimed renal authorities and their implementation was shown to correlate with patients' morbidity and mortality. This study was conducted to evaluate the adherence of healthcare professionals to the evidence-based clinical practice patterns in Khartoum State HD units. A cross-sectional study was conducted in Khartoum State HD units during the period from September 2010 to January of 2011. Data was collected from the healthcare professionals using a specially designed checklist. The checklist included the evidence-based clinical practice guidelines for the HD vascular access, HD adequacy, anemia of chronic kidney disease (CKD), nutrition, cardiovascular risk assessment, and hepatitis B and C virus infection control. Implementation of these guidelines was evaluated, and further graded using a Likert-type scale. Four randomly selected HD units were included in the study. The rate of implementation of the HD vascular access guidelines was 54.8%, adequacy guidelines 57%, anemia of CKD 68.8%, nutrition 58.4%, cardiovascular risk assessment 57%, and hepatitis B and C infection control guidelines was 79.2%. Overall, the four HD units assessed showed moderate deviations from the practice guidelines of anemia of CKD and hepatitis B and C infection control. Extreme deviations from the clinical practice guidelines were seen in HD vascular access practices, adequacy assessments, nutrition and cardiovascular risk assessment. Hemodialysis services in Khartoum State are in need of great improvements regarding adherence to protocols and the standards of care.
116. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), ...
116. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751), WITH CABINETS ON EAST SIDE OF ROOM FACING WEST. THE ROW OF CABINETS ON EAST SIDE OF ROOM INCLUDES LEFT TO RIGHT: CABLE DISTRIBUTION UNITS, AUTOPILOT CONTROLS, AND POWER DISTRIBUTION UNITS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Swivel arm perimeter for visual field testing in different body positions.
Flammer, J; Hendrickson, P; Lietz, A; Stümpfig, D
1993-01-01
To investigate the influence of body position on visual field results, a 'swivel arm perimeter' was built, based on a modified Octopus 1-2-3. Here, the measuring unit was detected from the control unit and mounted on a swivel arm, allowing its movement in all directions. The first results obtained with this device have indicated that its development was worthwhile.
NASA Astrophysics Data System (ADS)
Frey, Elaine F.
Even though environmental policy can greatly affect the path of technology diffusion, the economics literature contains limited empirical evidence of this relationship. My research will contribute to the available evidence by providing insight into the technology adoption decisions of electric generating firms. Since policies are often evaluated based on the incentives they provide to promote adoption of new technologies, it is important that policy makers understand the relationship between technological diffusion and regulation structure to make informed decisions. Lessons learned from this study can be used to guide future policies such as those directed to mitigate climate change. I first explore the diffusion of scrubbers, a sulfur dioxide (SO 2) abatement technology, in response to federal market-based regulations and state command-and-control regulations. I develop a simple theoretical model to describe the adoption decisions of scrubbers and use a survival model to empirically test the theoretical model. I find that power plants with strict command-and-control regulations have a high probability of installing a scrubber. These findings suggest that although market-based regulations have encouraged diffusion, many scrubbers have been installed because of state regulatory pressure. Although tradable permit systems are thought to give firms more flexibility in choosing abatement technologies, I show that interactions between a permit system and pre-existing command-and-control regulations can limit that flexibility. In a separate analysis, I explore the diffusion of combined cycle (CC) generating units, which are natural gas-fired generating units that are cleaner and more efficient than alternative generating units. I model the decision to consider adoption of a CC generating unit and the extent to which the technology is adopted in response to environmental regulations imposed on new sources of pollutants. To accomplish this, I use a zero-inflated Poisson model and focus on both the decision to adopt a CC unit at an existing power plant as well as the firm-level decision to adopt a CC unit in either a new or an existing power plant. Evidence from this empirical investigation shows that environmental regulation has a significant effect on both the decision to consider adoption as well as the extent of adoption.
Distributed Autonomous Control Action Based on Sensor and Mission Fusion
2005-09-01
programmable control algorithm driven by the readings of two pressure switch sensors located on either side of the valve unit. Thus, a micro-controller...and Characterization The process of leak detection and characterization must be accomplished with a set of pressure switch sensors. This sensor...economically supplementing existing widely used pressure switch type sensors which are characterized by prohibitively long inertial lag responses
A microprocessor-based real-time simulator of a turbofan engine
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Delaat, John C.; Merrill, Walter C.
1988-01-01
A real-time digital simulator of a Pratt and Whitney F 100 engine is discussed. This self-contained unit can operate in an open-loop stand-alone mode or as part of a closed-loop control system. It can also be used in control system design and development. It accepts five analog control inputs and its sixteen outputs are returned as analog signals.
Lakhani, Naheed; Brown, Phaeydra M.; Larkin, O. Ann; Moore, Angela R.; Hayes, Nikki S.
2013-01-01
Abstract Gynecologic cancer confers a large burden among women in the United States. Several evidence-based interventions are available to reduce the incidence, morbidity, and mortality from these cancers. The National Comprehensive Cancer Control Program (NCCCP) is uniquely positioned to implement these interventions in the US population. This review discusses progress and future directions for the NCCCP in preventing and controlling gynecologic cancer. PMID:23865787
Oxy-fired boiler unit and method of operating the same
Lou, Xinsheng; Zhang, Jundong; Joshi, Abhinaya; McCombe, James A.; Levasseur, Armand A.
2016-12-06
An oxy-combustion boiler unit is disclosed which includes a furnace for combusting fuel and for emitting flue gas resulting from combustion. The furnace has first, second and third combustion zones, and an air separation unit for separating oxygen gas from air and providing a first portion of the separated oxygen to a first oxidant flow, a second portion to a second oxidant flow, and a third portion of the separated oxygen gas to the first, second, and third zones of the furnace. A controller can cause the separated oxygen gas to be distributed so that the first and second oxygen flows have a desired oxygen content, and so that the first, second, and third zones of the furnace receive a desired amount of oxygen based on a combustion zone stoichiometry control.
Public policies on healthcare-associated infections: a Brazil and UK case study.
Padoveze, Maria Clara; Melo, Sara; Bishop, Simon; Poveda, Vanessa de Brito; Fortaleza, Carlos Magno Castelo Branco
2017-12-11
To summarize the historical events and drivers underlying public policy for the prevention and control of healthcare-associated infections in Brazil and in the United Kingdom. In doing so, the article aims to identify lessons and recommendations for future development of public policy. The analysis is based on a historical overview of national healthcare-associated infections programs taken from previously published sources. Findings highlight how the development of healthcare-associated infections prevention and control policies followed similar trajectories in Brazil and the United Kingdom. This can be conceptualized around four sequential phases: Formation, Consolidation, Standardization, and Monitoring and Evaluation. However, while we identified similar phases of development in Brazil and the United Kingdom, it can be seen that the former entered each stage around 20 years after the latter.
Technology review of flight crucial flight controls
NASA Technical Reports Server (NTRS)
Rediess, H. A.; Buckley, E. C.
1984-01-01
The results of a technology survey in flight crucial flight controls conducted as a data base for planning future research and technology programs are provided. Free world countries were surveyed with primary emphasis on the United States and Western Europe because that is where the most advanced technology resides. The survey includes major contemporary systems on operational aircraft, R&D flight programs, advanced aircraft developments, and major research and technology programs. The survey was not intended to be an in-depth treatment of the technology elements, but rather a study of major trends in systems level technology. The information was collected from open literature, personal communications and a tour of several companies, government organizations and research laboratories in the United States, United Kingdom, France, and the Federal Republic of Germany.
Selection and parameterization of cortical neurons for neuroprosthetic control.
Wahnoun, Remy; He, Jiping; Helms Tillery, Stephen I
2006-06-01
When designing neuroprosthetic interfaces for motor function, it is crucial to have a system that can extract reliable information from available neural signals and produce an output suitable for real life applications. Systems designed to date have relied on establishing a relationship between neural discharge patterns in motor cortical areas and limb movement, an approach not suitable for patients who require such implants but who are unable to provide proper motor behavior to initially tune the system. We describe here a method that allows rapid tuning of a population vector-based system for neural control without arm movements. We trained highly motivated primates to observe a 3D center-out task as the computer played it very slowly. Based on only 10-12 s of neuronal activity observed in M1 and PMd, we generated an initial mapping between neural activity and device motion that the animal could successfully use for neuroprosthetic control. Subsequent tunings of the parameters led to improvements in control, but the initial selection of neurons and estimated preferred direction for those cells remained stable throughout the remainder of the day. Using this system, we have observed that the contribution of individual neurons to the overall control of the system is very heterogeneous. We thus derived a novel measure of unit quality and an indexing scheme that allowed us to rate each neuron's contribution to the overall control. In offline tests, we found that fewer than half of the units made positive contributions to the performance. We tested this experimentally by having the animals control the neuroprosthetic system using only the 20 best neurons. We found that performance in this case was better than when the entire set of available neurons was used. Based on these results, we believe that, with careful task design, it is feasible to parameterize control systems without any overt behaviors and that subsequent control system design will be enhanced with cautious unit selection. These improvements can lead to systems demanding lower bandwidth and computational power, and will pave the way for more feasible clinical systems.
Credit PSR. This interior view of the building equipment room ...
Credit PSR. This interior view of the building equipment room displays heat exchangers and fan units with insulated piping for hot and cold water at left. Environmental controls and fire fighting system controls appear at right - Jet Propulsion Laboratory Edwards Facility, Propellant Curing Building, Edwards Air Force Base, Boron, Kern County, CA
75 FR 31763 - Enhanced Examination Timing Control Initiative; Notice of Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-04
...] Enhanced Examination Timing Control Initiative; Notice of Public Meeting AGENCY: United States Patent and...: This notice announces a public meeting to solicit public opinions on an initiative being considered by.... Under the initiative, for applications filed in the USPTO that are not based on a prior foreign- filed...
61. Upper panel in cornerpower panel lcpa lower panel in ...
61. Upper panel in corner-power panel lcpa lower panel in corner-oxygen regeneration unit, at right-air conditioner control panel, on floor-bio-pack 45 for emergency breathing, looking northwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
Decentralized Control of a Large Space Structure as Applied to the CSDL 2 Model.
1982-12-01
and are arranged by their respective controller assignments. The individual modes may be identified by the imaginary parts of the eigen- values, as...August 1958 to Phillip Z. and Hanako Y. Aldridge in Johnson Air Force Base, Japan. After a childhood in the United States, he returned to Japan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marc Cremer; Kirsi St. Marie; Dave Wang
2003-04-30
This is the first Semiannual Technical Report for DOE Cooperative Agreement No: DE-FC26-02NT41580. The goal of this project is to systematically assess the sensitivity of furnace operational conditions to burner air and fuel flows in coal fired utility boilers. Our approach is to utilize existing baseline furnace models that have been constructed using Reaction Engineering International's (REI) computational fluid dynamics (CFD) software. Using CFD analyses provides the ability to carry out a carefully controlled virtual experiment to characterize the sensitivity of NOx emissions, unburned carbon (UBC), furnace exit CO (FECO), furnace exit temperature (FEGT), and waterwall deposition to burner flowmore » controls. The Electric Power Research Institute (EPRI) is providing co-funding for this program, and instrument and controls experts from EPRI's Instrument and Controls (I&C) Center are active participants in this project. This program contains multiple tasks and good progress is being made on all fronts. A project kickoff meeting was held in conjunction with NETL's 2002 Sensors and Control Program Portfolio Review and Roadmapping Workshop, in Pittsburgh, PA during October 15-16, 2002. Dr. Marc Cremer, REI, and Dr. Paul Wolff, EPRI I&C, both attended and met with the project COR, Susan Maley. Following the review of REI's database of wall-fired coal units, the project team selected a front wall fired 150 MW unit with a Riley Low NOx firing system including overfire air for evaluation. In addition, a test matrix outlining approximately 25 simulations involving variations in burner secondary air flows, and coal and primary air flows was constructed. During the reporting period, twenty-two simulations have been completed, summarized, and tabulated for sensitivity analysis. Based on these results, the team is developing a suitable approach for quantifying the sensitivity coefficients associated with the parametric tests. Some of the results of the CFD simulations of the single wall fired unit were presented in a technical paper entitled, ''CFD Investigation of the Sensitivity of Furnace Operational Conditions to Burner Flow Controls,'' presented at the 28th International Technical Conference on Coal Utilization and Fuel Systems in Clearwater, FL March 9-14, 2003. In addition to the work completed on the single wall fired unit, the project team made the selection of a 580 MW opposed wall fired unit to be the subject of evaluation in this program. Work is in progress to update the baseline model of this unit so that the parametric simulations can be initiated.« less
Feedforward hysteresis compensation in trajectory control of piezoelectrically-driven nanostagers
NASA Astrophysics Data System (ADS)
Bashash, Saeid; Jalili, Nader
2006-03-01
Complex structural nonlinearities of piezoelectric materials drastically degrade their performance in variety of micro- and nano-positioning applications. From the precision positioning and control perspective, the multi-path time-history dependent hysteresis phenomenon is the most concerned nonlinearity in piezoelectric actuators to be analyzed. To realize the underlying physics of this phenomenon and to develop an efficient compensation strategy, the intelligent properties of hysteresis with the effects of non-local memories are discussed. Through performing a set of experiments on a piezoelectrically-driven nanostager with high resolution capacitive position sensor, it is shown that for the precise prediction of hysteresis path, certain memory units are required to store the previous hysteresis trajectory data. Based on the experimental observations, a constitutive memory-based mathematical modeling framework is developed and trained for the precise prediction of hysteresis path for arbitrarily assigned input profiles. Using the inverse hysteresis model, a feedforward control strategy is then developed and implemented on the nanostager to compensate for the system everpresent nonlinearity. Experimental results demonstrate that the controller remarkably eliminates the nonlinear effect if memory units are sufficiently chosen for the inverse model.
Establishment of local diagnostic reference levels for quality control in intraoral radiography.
Izawa, Maki; Harata, Yasuo; Shiba, Noriyoshi; Koizumi, Nobuhide; Ozawa, Tomonori; Takahashi, Nobutoshi; Okumura, Yasuhiko
2017-01-01
To investigate the dosage and imaging conditions for patients undergoing intraoral radiography at Meikai University Hospital and establish assurance and quality control data. Tube voltage, exposure time, and air kinetic energy released per unit mass (air kerma) of three intraoral radiography units were measured. To calculate the patient entrance dose (PED) for each radiograph using Insight film, we extracted data for 1063 patients from their exposure records. The PED was compared with the diagnostic reference level (DRL) from the European Commission and the UK. The tube voltage of the three units was maintained at 60 ± 2 kV. Differences in exposure time were less than 1.7 % for all units. The air kerma rates were well maintained within a 4.2 % error. Based on the patient data, there were no significant differences in the mean exposure times for males and females for all anatomical sites. The mean PED ranged from 1.09 ± 0.31 mGy for the mandibular incisors to 2.42 ± 0.33 mGy for the maxillary molars. The mean PED at the mandibular molars using InSight film was 1.59 ± 0.20 mGy, being less than the recommended value based on the DRL for intraoral radiography in the UK. We concluded that radiographic conditions at the hospital have been properly maintained. This basic quality control data may assist other dental radiation facilities to reduce patient dosage.
Le Dantec, Nicolas; Hogarth, Leah J.; Driscoll, Neal W.; Babcock, Jeffrey M.; Barnhardt, Walter A.; Schwab, William C.
2010-01-01
CHIRP seismic and swath bathymetry data acquired offshore La Jolla, California provide an unprecedented three-dimensional view of the La Jolla and Scripps submarine canyons. Shore-parallel patterns of tectonic deformation appear to control nearshore sediment thickness and distribution around the canyons. These shore-parallel patterns allow the impact of local tectonic deformation to be separated from the influence of eustatic sea-level fluctuations. Based on stratal geometry and acoustic character, we identify a prominent angular unconformity inferred to be the transgressive surface and three sedimentary sequences: an acoustically laminated estuarine unit deposited during early transgression, an infilling or “healing-phase” unit formed during the transgression, and an upper transparent unit. Beneath the transgressive surface, steeply dipping reflectors with several dip reversals record faulting and folding along the La Jolla margin. Scripps Canyon is located at the crest of an antiform, where the rocks are fractured and more susceptible to erosion. La Jolla Canyon is located along the northern strand of the Rose Canyon Fault Zone, which separates Cretaceous lithified rocks to the south from poorly cemented Eocene sands and gravels to the north. Isopach and structure contour maps of the three sedimentary units reveal how their thicknesses and spatial distributions relate to regional tectonic deformation. For example, the estuarine unit is predominantly deposited along the edges of the canyons in paleotopographic lows that may have been inlets along barrier beaches during the Holocene sea-level rise. The distribution of the infilling unit is controlled by pre-existing relief that records tectonic deformation and erosional processes. The thickness and distribution of the upper transparent unit are controlled by long-wavelength, tectonically induced relief on the transgressive surface and hydrodynamics.
Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo
2014-01-01
Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266
Characterization of the Advanced Stirling Radioisotope Generator EU2
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Oriti, Salvatore M.; Schifer, Nicholas A.
2015-01-01
Significant progress was made developing the Advanced Stirling Radioisotope Generator (ASRG), a 140-watt radioisotope power system. While the ASRG flight development project has ended, the hardware that was designed and built under the project is continuing to be tested to support future Stirling-based power system development. NASA GRC recently completed the assembly of the ASRG Engineering Unit 2 (EU2). The ASRG EU2 consists of the first pair of Sunpower's ASC-E3 Stirling convertors mounted in an aluminum housing, and Lockheed Martin's Engineering Development Unit (EDU) 4 controller (a fourth generation controller). The ASC-E3 convertors and Generator Housing Assembly (GHA) closely match the intended ASRG Qualification Unit flight design. A series of tests were conducted to characterize the EU2, its controller, and the convertors in the flight-like GHA. The GHA contained an argon cover gas for these tests. The tests included: measurement of convertor, controller, and generator performance and efficiency, quantification of control authority of the controller, disturbance force measurement with varying piston phase and piston amplitude, and measurement of the effect of spacecraft DC bus voltage on EU2 performance. The results of these tests are discussed and summarized, providing a basic understanding of EU2 characteristics and the performance and capability of the EDU 4 controller.
Spiegelman, Ronnie; Zhao, Vivian; Smiley, Dawn D.; Pinzon, Ingrid; Griffith, Daniel P.; Peng, Limin; Morris, Timothy; Luo, Menghua; Garcia, Hermes; Thomas, Christopher; Newton, Christopher A.; Ziegler, Thomas R.
2013-01-01
Objective Parenteral nutrition has been associated with metabolic and infectious complications in intensive care unit patients. The underlying mechanism for the high risk of complications is not known but may relate to the proinflammatory effects of soybean oil–based lipid emulsions, the only Food and Drug Administration–approved lipid formulation for clinical use. Design Prospective, double-blind, randomized, controlled trial. Setting Medical–surgical intensive care units from a major urban teaching hospital and a tertiary referral university hospital. Patients Adult medical–surgical intensive care unit patients. Intervention Parenteral nutrition containing soybean oil–based (Intralipid) or olive oil–based (ClinOleic) lipid emulsions. Measurements Differences in hospital clinical outcomes (nosocomial infections and noninfectious complications), hospital length of stay, glycemic control, inflammatory and oxidative stress markers, and granulocyte and monocyte functions between study groups. Results A total of 100 patients were randomized to either soybean oil–based parenteral nutrition or olive oil–based parenteral nutrition for up to 28 days. A total of 49 patients received soybean oil–based parenteral nutrition (age 51 ± 15 yrs, body mass index 27 ± 6 kg/m2, and Acute Physiology and Chronic Health Evaluation II score 15.5 ± 7 [±SD]), and a total of 51 patients received olive oil–based lipid emulsion in parenteral nutrition (age 46 ± 19 yrs, body mass index 27 ± 8 kg/m2, and Acute Physiology and Chronic Health Evaluation II score 15.1 ± 6 [±SD]) for a mean duration of 12.9 ± 8 days. The mean hospital blood glucose concentration during parenteral nutrition was 129 ± 14 mg/dL, without differences between groups. Patients treated with soybean oil–based and olive oil–based parenteral nutrition had a similar length of stay (47 ± 47 days and 41 ± 36 days, p = .49), mortality (16.3% and 9.8%, p = .38), nosocomial infections (43% vs. 57%, p = .16), and acute renal failure (26% vs. 18%, p = .34). In addition, there were no differences in inflammatory and oxidative stress markers or in granulocyte and monocyte functions between groups. Conclusion The administration of parenteral nutrition containing soybean oil–based and olive oil–based lipid emulsion resulted in similar rates of infectious and noninfectious complications and no differences in glycemic control, inflammatory and oxidative stress markers, and immune function in critically ill adults. PMID:22488002
Optimizing Web-Based Instruction: A Case Study Using Poultry Processing Unit Operations
ERIC Educational Resources Information Center
O' Bryan, Corliss A.; Crandall, Philip G.; Shores-Ellis, Katrina; Johnson, Donald M.; Ricke, Steven C.; Marcy, John
2009-01-01
Food companies and supporting industries need inexpensive, revisable training methods for large numbers of hourly employees due to continuing improvements in Hazard Analysis Critical Control Point (HACCP) programs, new processing equipment, and high employee turnover. HACCP-based food safety programs have demonstrated their value by reducing the…
Code of Federal Regulations, 2011 CFR
2011-01-01
..., proper nutrition, appropriate exercise, mental health, behavioral health, substance-use disorder, and... United States; (d) contains specific science-based initiatives to achieve the measurable goals of the... coordinated with science-based prevention recommendations by the Director of the Centers for Disease Control...
Based on the National Academy of Science’s 2004 report, “Air Quality Management in the United States”, the National Research Council (NRC) recommended to the US Environmental Protection Agency (EPA) that standard setting, planning, and control strategy development should be based...
Hospital cost control in Norway: a decade's experience with prospective payment.
Crane, T S
1985-01-01
Under Norway's prospective payment system, which was in existence from 1972 to 1980, hospital costs increased 15.8 percent annually, compared with 15.3 percent in the United States. In 1980 the Norwegian national government started paying for all institutional services according to a population-based, morbidity-adjusted formula. Norway's prospective payment system provides important insights into problems of controlling hospital costs despite significant differences, including ownership of medical facilities and payment and spending as a percent of GNP. Yet striking similarities exist. Annual real growth in health expenditures from 1972 to 1980 in Norway was 2.2 percent, compared with 2.4 percent in the United States. In both countries, public demands for cost control were accompanied by demands for more services. And problems of geographic dispersion of new technology and distribution of resources were similar. Norway's experience in the 1970s demonstrates that prospective payment is no panacea. The annual budget process created disincentives to hospitals to control costs. But Norway's changes in 1980 to a population-based methodology suggest a useful approach to achieve a more equitable distribution of resources. This method of payment provides incentives to control variations in both admissions and cost per case. In contrast, the Medicare approach based on Diagnostic Related Groups (DRGs) is limited, and it does not affect variations in admissions and capital costs. Population-based methodologies can be used in adjusting DRG rates to control both problems. In addition, the DRG system only applies to Medicare payments; the Norwegian experience demonstrates that this system may result in significant shifting of costs onto other payors. PMID:3927385
Coughlin, Mary; Gibbins, Sharyn; Hoath, Steven
2009-01-01
Title Core measures for developmentally supportive care in neonatal intensive care units: theory, precedence and practice. Aim This paper is a discussion of evidence-based core measures for developmental care in neonatal intensive care units. Background Inconsistent definition, application and evaluation of developmental care have resulted in criticism of its scientific merit. The key concept guiding data organization in this paper is the United States of America’s Joint Commission’s concept of ‘core measures’ for evaluating and accrediting healthcare organizations. This concept is applied to five disease- and procedure-independent measures based on the Universe of Developmental Care model. Data sources Electronically accessible, peer reviewed studies on developmental care published in English were culled for data supporting the selected objective core measures between 1978 and 2008. The quality of evidence was based on a structured predetermined format that included three independent reviewers. Systematic reviews and randomized control trials were considered the strongest level of evidence. When unavailable, cohort, case control, consensus statements and qualitative methods were considered the strongest level of evidence for a particular clinical issue. Discussion Five core measure sets for evidence-based developmental care were evaluated: (1) protected sleep, (2) pain and stress assessment and management, (3) developmental activities of daily living, (4) family-centred care, and (5) the healing environment. These five categories reflect recurring themes that emerged from the literature review regarding developmentally supportive care and quality caring practices in neonatal populations. This practice model provides clear metrics for nursing actions having an impact on the hospital experience of infant-family dyads. Conclusion Standardized disease-independent core measures for developmental care establish minimum evidence-based practice expectations and offer an objective basis for cross-institutional comparison of developmental care programmes. PMID:19686402
Fransen, A F; van de Ven, J; Schuit, E; van Tetering, Aac; Mol, B W; Oei, S G
2017-03-01
To investigate whether simulation-based obstetric team training in a simulation centre improves patient outcome. Multicentre, open, cluster randomised controlled trial. Obstetric units in the Netherlands. Women with a singleton pregnancy beyond 24 weeks of gestation. Random allocation of obstetric units to a 1-day, multi-professional, simulation-based team training focusing on crew resource management (CRM) in a simulation centre or to no such team training. Intention-to-treat analyses were performed at the cluster level, including a measurement 1 year prior to the intervention. Primary outcome was a composite outcome of obstetric complications during the first year post-intervention, including low Apgar score, severe postpartum haemorrhage, trauma due to shoulder dystocia, eclampsia and hypoxic-ischaemic encephalopathy. Maternal and perinatal mortality were also registered. Each study group included 12 units with a median unit size of 1224 women, combining for a total of 28 657 women. In total, 471 medical professionals received the training course. The composite outcome of obstetric complications did not differ between study groups [odds ratio (OR) 1.0, 95% confidence interval (CI) 0.80-1.3]. Team training reduced trauma due to shoulder dystocia (OR 0.50, 95% CI 0.25-0.99) and increased invasive treatment for severe postpartum haemorrhage (OR 2.2, 95% CI 1.2-3.9) compared with no intervention. Other outcomes did not differ between study groups. A 1-day, off-site, simulation-based team training, focusing on teamwork skills, did not reduce a composite of obstetric complications. 1-day, off-site, simulation-based team training did not reduce a composite of obstetric complications. © 2016 Royal College of Obstetricians and Gynaecologists.
1988-08-01
control data (lat tarK., lab spikes, and lab duplicates) in the report , as well as field quality control data. j. For those metiods which employ gas ...FORCE BASE, TEXAS 78235-5501 NOTICE This report has been prepared for the United States Air Force by Environmental Science and Engineering , Inc. (ESE...testing, field sampling, contamination assessment report preparation, and recommendations for remedial actions. U.S. Army Toxic and Hazardous Materials
Reactor vessel annealing system
Miller, Phillip E.; Katz, Leonoard R.; Nath, Raymond J.; Blaushild, Ronald M.; Tatch, Michael D.; Kordalski, Frank J.; Wykstra, Donald T.; Kavalkovich, William M.
1991-01-01
A system for annealing a vessel (14) in situ by heating the vessel (14) to a defined temperature, composed of: an electrically operated heater assembly (10) insertable into the vessel (14) for heating the vessel (14) to the defined temperature; temperature monitoring components positioned relative to the heater assembly (10) for monitoring the temperature of the vessel (14); a controllable electric power supply unit (32-60) for supplying electric power required by the heater assembly (10); a control unit (80-86) for controlling the power supplied by the power supply unit (32-60); a first vehicle (2) containing the power supply unit (32-60); a second vehicle (4) containing the control unit (80-86); power conductors (18,22) connectable between the power supply unit (32-60) and the heater unit (10) for delivering the power supplied by the power supply unit (32-60) to the heater assembly (10); signal conductors (20,24) connectable between the temperature monitoring components and the control unit (80-86) for delivering temperature indicating signals from the temperature monitoring components to the control unit (80-86); and control conductors (8) connectable between the control unit (80-86) and the power supply unit (32-60) for delivering to the power supply unit (32-60) control signals for controlling the level of power supplied by the power supply unit (32-60) to the heater assembly (10).
EVALUATING AND USING AIR QUALITY MODELS
Grid-based models are being used to assess the magnitude of the pollution problem and to design emission control strategies to achieve compliance with the relevant air quality standards in the United States.
The Effectiveness of Gaze-Contingent Control in Computer Games.
Orlov, Paul A; Apraksin, Nikolay
2015-01-01
Eye-tracking technology and gaze-contingent control in human-computer interaction have become an objective reality. This article reports on a series of eye-tracking experiments, in which we concentrated on one aspect of gaze-contingent interaction: Its effectiveness compared with mouse-based control in a computer strategy game. We propose a measure for evaluating the effectiveness of interaction based on "the time of recognition" the game unit. In this article, we use this measure to compare gaze- and mouse-contingent systems, and we present the analysis of the differences as a function of the number of game units. Our results indicate that performance of gaze-contingent interaction is typically higher than mouse manipulation in a visual searching task. When tested on 60 subjects, the results showed that the effectiveness of gaze-contingent systems over 1.5 times higher. In addition, we obtained that eye behavior stays quite stabile with or without mouse interaction. © The Author(s) 2015.
NASA Technical Reports Server (NTRS)
Bula, R. J.
1997-01-01
The ASTROCULTURE(trademark) plant growth unit flown as part on the STS-63 mission in February 1995, represented the first time plants were flown in microgravity in a enclosed controlled environment plant growth facility. In addition to control of the major environmental parameters, nutrients were provided to the plants with the ZEOPONICS system developed by NASA Johnson Space Center scientists. Two plant species were included in this space experiment, dwarf wheat (Triticum aestivum) and a unique mustard called "Wisconsin Fast Plants" (Brassica rapa). Extensive post-flight analyses have been performed on the plant material and it has been concluded that plant growth and development was normal during the period the plants were in the microgravity environment of space. However, adequate plant growth and development control data were not available for direct comparisons of plant responses to the microgravity environment with those of plants grown at 1 g. Such data would allow for a more complete interpretation of the extent that microgravity affects plant growth and development.
28 CFR 541.49 - Review of control unit placement.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Once every 30 days, the control unit team, comprised of the control unit manager and other members... required to attend the team meeting in order to be eligible for the previous month's stay in the control unit to be credited towards the projected duration of confinement in that unit. The unit team shall...
21 CFR 211.22 - Responsibilities of quality control unit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...
21 CFR 211.22 - Responsibilities of quality control unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...
Pound, Joe Mathews; Miller, John Allen; George, John E; Fish, Durland
2009-08-01
The Northeast Area-wide Tick Control Project (NEATCP) was funded by the United States Department of Agriculture (USDA) as a large-scale cooperative demonstration project of the USDA-Agricultural Research Service (ARS)-patented 4-Poster tick control technology (Pound et al. 1994) involving the USDA-ARS and a consortium of universities, state agencies, and a consulting firm at research locations in the five states of Connecticut (CT), Maryland (MD), New Jersey (NJ), New York (NY), and Rhode Island (RI). The stated objective of the project was "A community-based field trial of ARS-patented tick control technology designed to reduce the risk of Lyme disease in northeastern states." Here we relate the rationale and history of the technology, a chronological listing of events leading to implementation of the project, the original protocol for selecting treatment, and control sites, and protocols for deployment of treatments, sampling, assays, data analyses, and estimates of efficacy.
NASA Technical Reports Server (NTRS)
Chapman, David K.; Wells, H. William
1996-01-01
The plant growth facility (PGF), currently under development as a Space Shuttle middeck facility for the support of research on higher plants in microgravity, is presented. The PGF provides controlled fluorescent lighting and the active control of temperature, relative humidity and CO2 concentration. These parameters are designed to be centrally controlled by a dedicated microprocessor. The status of the experiment can be displayed for onboard analysis, and will be automatically archived for post-flight analysis. The facility is designed to operate for 15 days and will provide air filtration to remove ethylene and trace organics with replaceable potassium permanganate filters. Similar ground units will be available for pre-flight experimentation.
Design and Theoretical Analysis of a Resonant Sensor for Liquid Density Measurement
Zheng, Dezhi; Shi, Jiying; Fan, Shangchun
2012-01-01
In order to increase the accuracy of on-line liquid density measurements, a sensor equipped with a tuning fork as the resonant sensitive component is designed in this paper. It is a quasi-digital sensor with simple structure and high precision. The sensor is based on resonance theory and composed of a sensitive unit and a closed-loop control unit, where the sensitive unit consists of the actuator, the resonant tuning fork and the detector and the closed-loop control unit comprises precondition circuit, digital signal processing and control unit, analog-to-digital converter and digital-to-analog converter. An approximate parameters model of the tuning fork is established and the impact of liquid density, position of the tuning fork, temperature and structural parameters on the natural frequency of the tuning fork are also analyzed. On this basis, a tuning fork liquid density measurement sensor is developed. In addition, experimental testing on the sensor has been carried out on standard calibration facilities under constant 20 °C, and the sensor coefficients are calibrated. The experimental results show that the repeatability error is about 0.03% and the accuracy is about 0.4 kg/m3. The results also confirm that the method to increase the accuracy of liquid density measurement is feasible. PMID:22969378
Design and theoretical analysis of a resonant sensor for liquid density measurement.
Zheng, Dezhi; Shi, Jiying; Fan, Shangchun
2012-01-01
In order to increase the accuracy of on-line liquid density measurements, a sensor equipped with a tuning fork as the resonant sensitive component is designed in this paper. It is a quasi-digital sensor with simple structure and high precision. The sensor is based on resonance theory and composed of a sensitive unit and a closed-loop control unit, where the sensitive unit consists of the actuator, the resonant tuning fork and the detector and the closed-loop control unit comprises precondition circuit, digital signal processing and control unit, analog-to-digital converter and digital-to-analog converter. An approximate parameters model of the tuning fork is established and the impact of liquid density, position of the tuning fork, temperature and structural parameters on the natural frequency of the tuning fork are also analyzed. On this basis, a tuning fork liquid density measurement sensor is developed. In addition, experimental testing on the sensor has been carried out on standard calibration facilities under constant 20 °C, and the sensor coefficients are calibrated. The experimental results show that the repeatability error is about 0.03% and the accuracy is about 0.4 kg/m(3). The results also confirm that the method to increase the accuracy of liquid density measurement is feasible.
Vibration influence on control of single motor unit activity.
Malouin, F; Simard, T
1978-03-01
Effects of vibratory stimulation and maximal isometric contraction on a fine motor control task were evaluated in 17 human subjects. Electromyographic audiovisual feedback cues derived from two fine-wire bipolar electrodes, inserted to a depth of 12 and 6 mm respectively, were used to train the subjects to isolate a motor unit in the extensor carpi radialis brevis muscle. A specially designed compressed air driven vibrator providing vibratory stimulation with an amplitude of 2 mm and a frequency range of 120-160 cycles per second was applied to the muscle tendon. A significant decrease was found in the subjects; ability to isolate the pretest motor unit during and after continuous and interrupted periods of vibration and following a maximal isometric contraction of the extensor carpi radials brevis muscle. Individual variations in the subjects' responses to the forms of application of the vibratory stimulus, electrode preference and feedback specificity were observed. Results suggest that marked spatial recruitment of motor units, brought into action by the vibration stimulus or by the maximal isometric contraction, interfered with inhibitory mechanisms necessary to achieve isolation and control of a single motor unit. A therapeutic application of vibration, based on the marked spatial recruitment observed during and after vibration, is proposed for muscle reeducation.
Spahr, N.E.; Boulger, R.W.
1997-01-01
Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.
Note: Wide-operating-range control for thermoelectric coolers.
Peronio, P; Labanca, I; Ghioni, M; Rech, I
2017-11-01
A new algorithm for controlling the temperature of a thermoelectric cooler is proposed. Unlike a classic proportional-integral-derivative (PID) control, which computes the bias voltage from the temperature error, the proposed algorithm exploits the linear relation that exists between the cold side's temperature and the amount of heat that is removed per unit time. Since this control is based on an existing linear relation, it is insensitive to changes in the operating point that are instead crucial in classic PID control of a non-linear system.
Note: Wide-operating-range control for thermoelectric coolers
NASA Astrophysics Data System (ADS)
Peronio, P.; Labanca, I.; Ghioni, M.; Rech, I.
2017-11-01
A new algorithm for controlling the temperature of a thermoelectric cooler is proposed. Unlike a classic proportional-integral-derivative (PID) control, which computes the bias voltage from the temperature error, the proposed algorithm exploits the linear relation that exists between the cold side's temperature and the amount of heat that is removed per unit time. Since this control is based on an existing linear relation, it is insensitive to changes in the operating point that are instead crucial in classic PID control of a non-linear system.
Quantum optimal control with automatic differentiation using graphics processors
NASA Astrophysics Data System (ADS)
Leung, Nelson; Abdelhafez, Mohamed; Chakram, Srivatsan; Naik, Ravi; Groszkowski, Peter; Koch, Jens; Schuster, David
We implement quantum optimal control based on automatic differentiation and harness the acceleration afforded by graphics processing units (GPUs). Automatic differentiation allows us to specify advanced optimization criteria and incorporate them into the optimization process with ease. We will describe efficient techniques to optimally control weakly anharmonic systems that are commonly encountered in circuit QED, including coupled superconducting transmon qubits and multi-cavity circuit QED systems. These systems allow for a rich variety of control schemes that quantum optimal control is well suited to explore.
A Community Intervention to Decrease Antibiotics Used for Self-Medication Among Latino Adults
Mainous, Arch G.; Diaz, Vanessa A.; Carnemolla, Mark
2009-01-01
PURPOSE Recent evidence in Latino communities indicates substantial self-medication with antibiotics obtained without a prescription (WORx). We implemented and evaluated a culturally sensitive educational intervention to decrease antibiotic self-medication. METHODS We conducted a community-based intervention with preintervention and postintervention measures in the intervention community (Charleston, South Carolina) as well as a postintervention measure in a control community (Greenville, South Carolina) 200 miles away. The 9-month culturally sensitive intervention included multiple media sources (pamphlets, radio, newspapers). We evaluated the use of antibiotics WORx in the United States, as well as the likelihood of importing antibiotics, by surveying Latino adults in the intervention (n = 250) and in the control community (n = 250). RESULTS Most adults in the intervention community (69%) and the control community (60%) reported some exposure to messages about the inappropriate use of antibiotics, and 25.9% in the intervention community and 8.6% in the control community reported seeing our patient education pamphlets. A substantial proportion of Latino adults in both the intervention (31%) and control communities (20%) have obtained antibiotics WORx in the United States. In multivariate analyses, exposure to an educational message was not a significant predictor of having acquired antibiotics WORx in the United States in past 12 months. The primary predictor of respondents’ having acquired antibiotics WORx in the United States was whether they had bought antibiotics WORx outside the United States. CONCLUSIONS Novel approaches are needed to decrease the use of antibiotics WORx in Latino communities, as focusing only on education may not be sufficient to change behaviors common in their home countries. PMID:19901311
Mechatronic design of a fully integrated camera for mini-invasive surgery.
Zazzarini, C C; Patete, P; Baroni, G; Cerveri, P
2013-06-01
This paper describes the design features of an innovative fully integrated camera candidate for mini-invasive abdominal surgery with single port or transluminal access. The apparatus includes a CMOS imaging sensor, a light-emitting diode (LED)-based unit for scene illumination, a photodiode for luminance detection, an optical system designed according to the mechanical compensation paradigm, an actuation unit for enabling autofocus and optical zoom, and a control logics based on microcontroller. The bulk of the apparatus is characterized by a tubular shape with a diameter of 10 mm and a length of 35 mm. The optical system, composed of four lens groups, of which two are mobile, has a total length of 13.46 mm and an effective focal length ranging from 1.61 to 4.44 mm with a zoom factor of 2.75×, with a corresponding angular field of view ranging from 16° to 40°. The mechatronics unit, devoted to move the zoom and the focus lens groups, is implemented adopting miniature piezoelectric motors. The control logics implements a closed-loop mechanism, between the LEDs and photodiode, to attain automatic control light. Bottlenecks of the design and some potential issues of the realization are discussed. A potential clinical scenario is introduced.
Light weight portable operator control unit using an Android-enabled mobile phone
NASA Astrophysics Data System (ADS)
Fung, Nicholas
2011-05-01
There have been large gains in the field of robotics, both in hardware sophistication and technical capabilities. However, as more capable robots have been developed and introduced to battlefield environments, the problem of interfacing with human controllers has proven to be challenging. Particularly in the field of military applications, controller requirements can be stringent and can range from size and power consumption, to durability and cost. Traditional operator control units (OCUs) tend to resemble laptop personal computers (PCs), as these devices are mobile and have ample computing power. However, laptop PCs are bulky and have greater power requirements. To approach this problem, a light weight, inexpensive controller was created based on a mobile phone running the Android operating system. It was designed to control an iRobot Packbot through the Army Research Laboratory (ARL) in-house Agile Computing Infrastructure (ACI). The hardware capabilities of the mobile phone, such as Wi- Fi communications, touch screen interface, and the flexibility of the Android operating system, made it a compelling platform. The Android based OCU offers a more portable package and can be easily carried by a soldier along with normal gear requirements. In addition, the one hand operation of the Android OCU allows for the Soldier to keep an unoccupied hand for greater flexibility. To validate the Android OCU as a capable controller, experimental data was collected evaluating use of the controller and a traditional, tablet PC based OCU. Initial analysis suggests that the Android OCU performed positively in qualitative data collected from participants.
Method and system for redundancy management of distributed and recoverable digital control system
NASA Technical Reports Server (NTRS)
Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)
2012-01-01
A method and system for redundancy management is provided for a distributed and recoverable digital control system. The method uses unique redundancy management techniques to achieve recovery and restoration of redundant elements to full operation in an asynchronous environment. The system includes a first computing unit comprising a pair of redundant computational lanes for generating redundant control commands. One or more internal monitors detect data errors in the control commands, and provide a recovery trigger to the first computing unit. A second redundant computing unit provides the same features as the first computing unit. A first actuator control unit is configured to provide blending and monitoring of the control commands from the first and second computing units, and to provide a recovery trigger to each of the first and second computing units. A second actuator control unit provides the same features as the first actuator control unit.
A programmable and portable NMES device for drop foot correction and blood flow assist applications.
Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid
2009-04-01
The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.
A programmable and portable NMES device for drop foot correction and blood flow assist applications.
Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; OLaighin, Gearoid
2007-01-01
The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor based foot switches and NMES based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.
NASA Astrophysics Data System (ADS)
Wahid, A.; Taqwallah, H. M. H.
2018-03-01
Compressors and a steam reformer are the important units in biohydrogen from biomass plant. The compressors are useful for achieving high-pressure operating conditions while the steam reformer is the main process to produce H2 gas. To control them, in this research used a model predictive control (MPC) expected to have better controller performance than conventional controllers. Because of the explicit model empowerment in MPC, obtaining a better model is the main objective before employing MPC. The common way to get the empirical model is through the identification system, so that obtained a first-order plus dead-time (FOPDT) model. This study has already improved that way since used the system re-identification (SRI) based on closed loop mode. Based on this method the results of the compressor pressure control and temperature control of steam reformer were that MPC based on system re-identification (MPC-SRI) has better performance than MPC without system re-identification (MPCWSRI) and the proportional-integral (PI) controller, by % improvement of 73% against MPCWSRI and 75% against the PI controller.
A tactile-output paging communication system for the deaf-blind
NASA Technical Reports Server (NTRS)
Baer, J. A.
1979-01-01
A radio frequency paging communication system that has coded vibrotactile outputs suitable for use by deaf-blind people was developed. In concept, the system consists of a base station transmitting and receiving unit and many on-body transmitting and receiving units. The completed system has seven operating modes: fire alarm; time signal; repeated single character Morse code; manual Morse code; emergency aid request; operational status test; and message acknowledge. The on-body units can be addressed in three ways: all units; a group of units; or an individual unit. All the functions developed were integrated into a single package that can be worn on the user's wrist. The control portion of the on-body unit is implemented by a microcomputer. The microcomputer is packaged in a custom-designed hybrid circuit to reduce its physical size.
Thermoacoustic focusing lens by symmetric Airy beams with phase manipulations
NASA Astrophysics Data System (ADS)
Liu, Chen; Xia, Jian-Ping; Sun, Hong-Xiang; Yuan, Shou-Qi
2017-12-01
We report the realization of broadband acoustic focusing lenses based on two symmetric thermoacoustic phased arrays of Airy beams, in which the units of thermoacoustic phase control are designed by employing air with different temperatures surrounded by rigid insulated boundaries and thermal insulation films. The phase delays of the transmitted and reflected units could cover a whole 2π interval, which arises from the change of the sound velocity of air induced by the variation of the temperature. Based on the units of phase control, we design the transmitted and reflected acoustic focusing lenses with two symmetric Airy beams, and verify the high self-healing focusing characteristic and the feasibility of the thermal insulation films. Besides, the influences of the bending angle of the Airy beam on the focusing performance are discussed in detail. The proposed acoustic lens has advantages of broad bandwidth (about 4.8 kHz), high focusing performance, self-healing feature, and simple structure, which enable it to provide more schemes for acoustic focusing. It has excellent potential applications in acoustic devices.
IEEE 1451.2 based Smart sensor system using ADuc847
NASA Astrophysics Data System (ADS)
Sreejithlal, A.; Ajith, Jose
IEEE 1451 standard defines a standard interface for connecting transducers to microprocessor based data acquisition systems, instrumentation systems, control and field networks. Smart transducer interface module (STIM) acts as a unit which provides signal conditioning, digitization and data packet generation functions to the transducers connected to it. This paper describes the implementation of a microcontroller based smart transducer interface module based on IEEE 1451.2 standard. The module, implemented using ADuc847 microcontroller has 2 transducer channels and is programmed using Embedded C language. The Sensor system consists of a Network Controlled Application Processor (NCAP) module which controls the Smart transducer interface module (STIM) over an IEEE1451.2-RS232 bus. The NCAP module is implemented as a software module in C# language. The hardware details, control principles involved and the software implementation for the STIM are described in detail.
Assembly of hydrogel units for 3D microenvironment in a poly(dimethylsiloxane) channel
NASA Astrophysics Data System (ADS)
Cho, Chang Hyun; Kwon, Seyong; Park, Je-Kyun
2017-12-01
Construction of three-dimensional (3D) microenvironment become an important issue in recent biological studies due to their biological relevance compared to conventional two-dimensional (2D) microenvironment. Various fabrication techniques have been employed to construct a 3D microenvironment, however, it is difficult to fully satisfy the biological and mechanical properties required for the 3D cell culture system, such as heterogeneous tissue structures generated from the functional differences or diseases. We propose here an assembly method for facile construction of 3D microenvironment in a poly(dimethylsiloxane) (PDMS) channel using hydrogel units. The high-aspect-ratio of hydrogel units was achieved by fabricating these units using a 2D mold. With this approach, 3D heterogeneous hydrogel units were produced and assembled in a PDMS channel by structural hookup. In vivo-like 3D heterogeneous microenvironment in a precisely controllable fluidic system was also demonstrated using a controlled assembly of different types of hydrogel units, which was difficult to obtain from previous methods. By regulating the flow condition, the mechanical stability of the assembled hydrogel units was verified by the flow-induced deformation of hydrogel units. In addition, in vivo-like cell culture environment was demonstrated using an assembly of cell-coated hydrogel units in the fluidic channel. Based on these features, our method expects to provide a beneficial tool for the 3D cell culture module and biomimetic engineering.
Application of Multivariable Model Predictive Advanced Control for a 2×310T/H CFB Boiler Unit
NASA Astrophysics Data System (ADS)
Weijie, Zhao; Zongllao, Dai; Rong, Gou; Wengan, Gong
When a CFB boiler is in automatic control, there are strong interactions between various process variables and inverse response characteristics of bed temperature control target. Conventional Pill control strategy cannot deliver satisfactory control demand. Kalman wave filter technology is used to establish a non-linear combustion model, based on the CFB combustion characteristics of bed fuel inventory, heating values, bed lime inventory and consumption. CFB advanced combustion control utilizes multivariable model predictive control technology to optimize primary and secondary air flow, bed temperature, air flow, fuel flow and heat flux. In addition to providing advanced combustion control to 2×310t/h CFB+1×100MW extraction condensing turbine generator unit, the control also provides load allocation optimization and advanced control for main steam pressure, combustion and temperature. After the successful implementation, under 10% load change, main steam pressure varied less than ±0.07MPa, temperature less than ±1°C, bed temperature less than ±4°C, and air flow (O2) less than ±0.4%.
Values based decision making: a tool for achieving the goals of healthcare.
Mills, Anne E; Spencer, Edward M
2005-03-01
The recognition that the success of the healthcare organization depends on its achievement of two interrelated goals is a relatively recent phenomenon. In its mid-history the healthcare organization was largely able to ignore cost issues. In its latter history, many would argue that it ignored its quality goals as it pursued its cost goals (15). Either approach, given declining revenues and a competitive landscape, is incompatible with continued responsible operation. If this is true, then tools that were appropriate when the healthcare organization was focused on the achievement of one or another of these goals are not adequate as the healthcare organization seeks to achieve both goals together. Thus, new perspectives and new tools must be found that help the organization address two intimately related but sometimes conflicting goals. Values based decision-making can be the perspective needed, and organization ethics is one tool that can be of use in supporting it within the institution. But there are caveats. In order for values based decision-making to be effective, leadership must take an active role in promoting its use. It must relinquish a degree of control and it must begin to trust its stakeholders to make decisions within the context of the organization's values and goals. This can be extremely difficult, as control by senior management is often seen as the only effective means of ensuring that correct decisions are made. There are additional difficulties in the healthcare organization. Control rests within two groups and the healthcare organization is operating in an environment in which variance elimination is emphasized as a means of controlling costs. This may be an appealing notion for revenue strapped healthcare organization leaders, but it implies greater control exerted by managers, not less. Relinquishing any degree of control is a frightening prospect, but it has been done successfully. An excellent example of leadership encouraging decisions based on values was presented by a unit administrator frustrated by the hierarchical structure and ponderous rituals of a traditional intensive care unit. Invoking a management tool called "the balanced scorecard" (which recognizes the multiplicity of goals and values in any organization) he identified the goals and values of the unit, and with the help and input of his staff he restructured it into functional multidisciplinary "teams" organized around tasks and goals which were based on values. The transformation of identities of unit members from their job description to their accomplishments improved both the efficiency of the unit and its morale--as well as resulting in cost savings. In this example teams had to learn to work together, collaborate and disregard the fear of doing things differently. Staff had to be motivated and feedback was necessary to ensure goals rather then rules were being meet. The balanced scorecard was implemented with mechanisms to support the communication and collaboration necessary to achieve the goals of the unit. The experiment was successful, but only because leadership recognized that multiple goals and multiple values were involved, that were explicitly articulated with the priority of excellent care. But once leadership was sure that "shared vision" existed leadership was able to trust staff to make appropriate decisions to realize that vision.
WOLF REXUS EXPERIMENT - European Planetary Science Congress
NASA Astrophysics Data System (ADS)
Buzdugan, A.
2017-09-01
WOLF experiment is developing a reaction wheel-based control system, effectively functioning as active nutation damper. One reaction wheel is used to reduce the undesirable lateral rates of spinning cylindrically symmetric free falling units, ejected from a sounding rocket. Once validated in REXUS flight, the concept and the design developed during WOLF experiment can be used for other application which require a flat spin of the free falling units.
97. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), ...
97. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770). EAST ROW OF CABINETS INCLUDES, LEFT TO RIGHT: CABLE DISTRIBUTION UNITS, AUTOPILOT CHECKOUT CONTROLS, AND POWER DISTRIBUTION UNITS. NOTE OVERHEAD DUCTS FOR INSTRUMENT AIR CONDITIONING AND CABLE TRAYS ON EAST, WEST, AND SOUTH WALLS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
United Stirling's Solar Engine Development: the Background for the Vanguard Engine
NASA Technical Reports Server (NTRS)
Holgersson, S.
1984-01-01
The development and testing resulting in the Vanguard engine and some of the characteristics of the Stirling engine based power conversion unit are described. The major part of the solar engine development is concentrated to the three different areas, the receiver, the lubrication system and the control system. Five engines are on test within the solar project. The function of the components are validated in actual solar tests.
AFWL Standards for Scientific and Technical Reports.
1980-04-01
Air Force Weapons Laboratory , Kirtland Air Force Base, New Mexico, under...PROGRAM ELEMEN T PROJECT TASK AREA & WORK UNIT NUMBERS Air Force Weapons Laboratory (SUR) Kirtland Air Force Base, NM 87117 62601F/99930000 I. CONTROLLING...OFFICE NAME AND ADDRESS 12 REPORT DATE Air Force Weapons Laboratory (SUR) April 1980 Kirtland Air Force Base, NM 87117 13. NUMBER OF PAGES 72
Building on a Foundation of Strength: Fiscal Year 2012 United States Army Annual Financial Report
2012-01-01
competency-based training in conjunction with the Army competency management system. Â Fellowships and experience-broadening interagency, international ...operations. This section focuses on the Army’s system of internal controls to comply with such laws as the Federal Financial Management Improvement Act...accurate financial information through efficient and effective internal controls. By having effective internal controls, the Army is able to improve
Remodeling Air Force Cyber Command and Control
2017-10-10
AIR FORCE CYBERWORX REPORT: REMODELING AIR FORCE CYBER COMMAND & CONTROL COURSE DESIGN PROJECT CONDUCTED 5 Jan – 5 May 17 Produced...For the Air Force Cyber Command and Control (C2) Design Project, CyberWorx brought together 25 cadets from the United States Air Force Academy...warfighting based upon the findings of the design teams. Participants The design course was attended by a diverse group of civilians from industry
Controlled Secure Direct Communication with Seven-Qubit Entangled States
NASA Astrophysics Data System (ADS)
Wang, Shu-Kai; Zha, Xin-Wei; Wu, Hao
2018-01-01
In this paper, a new controlled secure direct communication protocol based on a maximally seven-qubit entangled state is proposed. the outcomes of measurement is performed by the sender and the controller, the receiver can obtain different secret messages in a deterministic way with unit successful probability.In this scheme,by using entanglement swapping, no qubits carrying secret messages are transmitted.Therefore, the protocol is completely secure.
Portable Dynamic Pressure Calibrator
NASA Technical Reports Server (NTRS)
Wright, Morgan S.; Maynard, Everett (Technical Monitor)
1996-01-01
A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.
USDA-ARS?s Scientific Manuscript database
The work of Stern and colleagues on integrated control has had long-lasting effects on development of IPM programs in orchard systems. Management systems based solely on pesticides have proven to be unstable, and the success of IPM systems in orchards has been driven by the conservation of natural ...
Screening tests of chemical deterrents
Arthur R. Hastings; Morton Beroza
1961-01-01
Despite intensive research and zealous control efforts, the Dutch elm disease continues to kill valuable ornamental and wild elm trees over wide areas in the United States and Canada. Control of the disease at present is based on sanitation, the removal of dead and dying ornamental trees, and use of insecticides to kill the insects that carry the disease. The primary...
Friction Stir Weld System for Welding and Weld Repair
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey (Inventor); Romine, Peter L. (Inventor); Oelgoetz, Peter A. (Inventor)
2001-01-01
A friction stir weld system for welding and weld repair has a base foundation unit connected to a hydraulically controlled elevation platform and a hydraulically adjustable pin tool. The base foundation unit may be fixably connected to a horizontal surface or may be connected to a mobile support in order to provide mobility to the friction stir welding system. The elevation platform may be utilized to raise and lower the adjustable pin tool about a particular axis. Additional components which may be necessary for the friction stir welding process include back plate tooling, fixturing and/or a roller mechanism.
Gong, Jianxiao; Steinsultz, Nat; Ouyang, Min
2016-06-08
The ability to control the interaction between nitrogen-vacancy centres in diamond and photonic and/or broadband plasmonic nanostructures is crucial for the development of solid-state quantum devices with optimum performance. However, existing methods typically employ top-down fabrication, which restrict scalable and feasible manipulation of nitrogen-vacancy centres. Here, we develop a general bottom-up approach to fabricate an emerging class of freestanding nanodiamond-based hybrid nanostructures with external functional units of either plasmonic nanoparticles or excitonic quantum dots. Precise control of the structural parameters ( including size, composition, coverage and spacing of the external functional units) is achieved, representing a pre-requisite for exploring themore » underlying physics. Fine tuning of the emission characteristics through structural regulation is demonstrated by performing single-particle optical studies. Lastly, this study opens a rich toolbox to tailor properties of quantum emitters, which can facilitate design guidelines for devices based on nitrogen vacancy centres that use these freestanding hybrid nanostructures as building blocks.« less
2017-01-01
We selected iOS in this study as the App operation system, Objective-C as the programming language, and Oracle as the database to develop an App to inspect controlled substances in patient care units. Using a web-enabled smartphone, pharmacist inspection can be performed on site and the inspection result can be directly recorded into HIS through the Internet, so human error of data translation can be minimized and the work efficiency and data processing can be improved. This system not only is fast and convenient compared to the conventional paperwork, but also provides data security and accuracy. In addition, there are several features to increase inspecting quality: (1) accuracy of drug appearance, (2) foolproof mechanism to avoid input errors or miss, (3) automatic data conversion without human judgments, (4) online alarm of expiry date, and (5) instant inspection result to show not meted items. This study has successfully turned paper-based medication inspection into inspection using a web-based mobile device. PMID:28286761
Lu, Ying-Hao; Lee, Li-Yao; Chen, Ying-Lan; Cheng, Hsing-I; Tsai, Wen-Tsung; Kuo, Chen-Chun; Chen, Chung-Yu; Huang, Yaw-Bin
2017-01-01
We selected iOS in this study as the App operation system, Objective-C as the programming language, and Oracle as the database to develop an App to inspect controlled substances in patient care units. Using a web-enabled smartphone, pharmacist inspection can be performed on site and the inspection result can be directly recorded into HIS through the Internet, so human error of data translation can be minimized and the work efficiency and data processing can be improved. This system not only is fast and convenient compared to the conventional paperwork, but also provides data security and accuracy. In addition, there are several features to increase inspecting quality: (1) accuracy of drug appearance, (2) foolproof mechanism to avoid input errors or miss, (3) automatic data conversion without human judgments, (4) online alarm of expiry date, and (5) instant inspection result to show not meted items. This study has successfully turned paper-based medication inspection into inspection using a web-based mobile device.
NASA Astrophysics Data System (ADS)
Gong, Jianxiao; Steinsultz, Nat; Ouyang, Min
2016-06-01
The ability to control the interaction between nitrogen-vacancy centres in diamond and photonic and/or broadband plasmonic nanostructures is crucial for the development of solid-state quantum devices with optimum performance. However, existing methods typically employ top-down fabrication, which restrict scalable and feasible manipulation of nitrogen-vacancy centres. Here, we develop a general bottom-up approach to fabricate an emerging class of freestanding nanodiamond-based hybrid nanostructures with external functional units of either plasmonic nanoparticles or excitonic quantum dots. Precise control of the structural parameters (including size, composition, coverage and spacing of the external functional units) is achieved, representing a pre-requisite for exploring the underlying physics. Fine tuning of the emission characteristics through structural regulation is demonstrated by performing single-particle optical studies. This study opens a rich toolbox to tailor properties of quantum emitters, which can facilitate design guidelines for devices based on nitrogen-vacancy centres that use these freestanding hybrid nanostructures as building blocks.
Odman, M Talat; Hu, Yongtao; Russell, Armistead G; Hanedar, Asude; Boylan, James W; Brewer, Patricia F
2009-07-01
A detailed sensitivity analysis was conducted to quantify the contributions of various emission sources to ozone (O3), fine particulate matter (PM2.5), and regional haze in the Southeastern United States. O3 and particulate matter (PM) levels were estimated using the Community Multiscale Air Quality (CMAQ) modeling system and light extinction values were calculated from modeled PM concentrations. First, the base case was established using the emission projections for the year 2009. Then, in each model run, SO2, primary carbon (PC), NH3, NO(x) or VOC emissions from a particular source category in a certain geographic area were reduced by 30% and the responses were determined by calculating the difference between the results of the reduced emission case and the base case. The sensitivity of summertime O3 to VOC emissions is small in the Southeast and ground-level NO(x) controls are generally more beneficial than elevated NO(x) controls (per unit mass of emissions reduced). SO2 emission reduction is the most beneficial control strategy in reducing summertime PM2.5 levels and improving visibility in the Southeast and electric generating utilities are the single largest source of SO2. Controlling PC emissions can be very effective locally, especially in winter. Reducing NH3 emissions is an effective strategy to reduce wintertime ammonium nitrate (NO3NH4) levels and improve visibility; NO(x) emissions reductions are not as effective. The results presented here will help the development of specific emission control strategies for future attainment of the National Ambient Air Quality Standards in the region.
2004-01-01
Based Research Inc . 1595 Spring Hill Road, Suite 250 Vienna, VA 22182-2216 Wheatleyg@je.jfcom.mil Mr. J. Wilder UNITED STATES US. Army Training...Sarin, 2000). Collaboration C2 Metrics The following collaboration metrics have evolved out of work done by Evidence Based Research, Inc . for the...Enemy, Troops, Terrain, Troops, Time, and Civil considerations OOTW Operations Other Than War PESTLE Political, Economic, Social, Technological
Logistic-based patient grouping for multi-disciplinary treatment.
Maruşter, Laura; Weijters, Ton; de Vries, Geerhard; van den Bosch, Antal; Daelemans, Walter
2002-01-01
Present-day healthcare witnesses a growing demand for coordination of patient care. Coordination is needed especially in those cases in which hospitals have structured healthcare into specialty-oriented units, while a substantial portion of patient care is not limited to single units. From a logistic point of view, this multi-disciplinary patient care creates a tension between controlling the hospital's units, and the need for a control of the patient flow between units. A possible solution is the creation of new units in which different specialties work together for specific groups of patients. A first step in this solution is to identify the salient patient groups in need of multi-disciplinary care. Grouping techniques seem to offer a solution. However, most grouping approaches in medicine are driven by a search for pathophysiological homogeneity. In this paper, we present an alternative logistic-driven grouping approach. The starting point of our approach is a database with medical cases for 3,603 patients with peripheral arterial vascular (PAV) diseases. For these medical cases, six basic logistic variables (such as the number of visits to different specialist) are selected. Using these logistic variables, clustering techniques are used to group the medical cases in logistically homogeneous groups. In our approach, the quality of the resulting grouping is not measured by statistical significance, but by (i) the usefulness of the grouping for the creation of new multi-disciplinary units; (ii) how well patients can be selected for treatment in the new units. Given a priori knowledge of a patient (e.g. age, diagnosis), machine learning techniques are employed to induce rules that can be used for the selection of the patients eligible for treatment in the new units. In the paper, we describe the results of the above-proposed methodology for patients with PAV diseases. Two groupings and the accompanied classification rule sets are presented. One grouping is based on all the logistic variables, and another grouping is based on two latent factors found by applying factor analysis. On the basis of the experimental results, we can conclude that it is possible to search for medical logistic homogenous groups (i) that can be characterized by rules based on the aggregated logistic variables; (ii) for which we can formulate rules to predict to which cluster new patients belong.
A new look at Togo through the eyes of a SLAR
NASA Technical Reports Server (NTRS)
Dellwig, L. F.
1980-01-01
Imaging of Togo in 1977 with SLAR provided the data required for the production of map controlled radar mosaics at a scale of 1:200,000 with 95 percent of all control points at that scale within + or - 4.0 millimeters of true positions. The moasics served as the base for the generation of a revised geologic map of Togo. Aided by two looks, numerous revisions resulted, not only with the addition of previously unknown structural features, a revision of age relationships, and the refinement of unit boundaries, but also with the repositioning of rock units and the reorientation of major faults.
Influence of organic buffers on bacteriocin production by Streptococcus thermophilus ST110.
Somkuti, George A; Gilbreth, Stefanie E
2007-08-01
The effect of the organic buffer salts MES, MOPS, and PIPES on the growth of S. thermophilus ST110, medium pH, and accumulation of the antipediococcal bacteriocin thermophilin 110 were evaluated in whey permeate media over a period of 24 h. In nonbuffered medium, thermophilin 110 production at 37 degrees C paralleled the growth of S. thermophilus ST110 and reached a maximum after 8-10 h. Addition of organic buffer salts decreased the drop in medium pH and resulted in increased biomass (dry cells; microg/mL) and higher yields of thermophilin 110 (units/microg cells). The best results were obtained by the addition of 1% (w/v) MES to the medium, which reduced the pH drop to 1.8 units after 10 h of growth (compared to 2.3 pH units in the control) and resulted in a 1.5-fold increase in cell mass (495 microg/mL) and a 7-fold increase in thermophilin 110 yield (77 units/microg dry cells) over the control. The results showed that whey permeate-based media may be suitable for producing large amounts of thermophilin 110 needed for controlling spoilage pediococci in industrial wine and beer fermentations.
NASA Astrophysics Data System (ADS)
Chow, J. M.; Bart, P. J.
2005-05-01
Ross Sea (Antarctica) Eastern Basin bathymetric ridges have been interpreted to be ice stream divides created during the Last Glacial Maximum (LGM) advance of the Antarctic Ice Sheet based on radiocarbon dating of organic matter from near-seafloor sediments recovered in piston cores (Domack et al., 1999). Detailed seismic correlations and contour mapping show that there are at least five thick units outcropping in Eastern Basin. Four of these seismically-defined units can be correlated to age control at DSDP sites 270 and 272. In contrast to the near-seafloor sampling, the interiors of these units were initially assigned a Pliocene age based on a variety of microfossil biozones (Hayes and Frakes, 1975). Savage and Ciesielski (1983) determined that the youngest unit was deposited during the Coscinodiscus lentiginosus (since renamed Thalassiosira lentiginosa) diatom biozone (i.e., the unit formed sometime between 0.65 Ma to Recent timeframe). Thus, seafloor units in the area probably are of Quaternary age, but not necessarily LGM age. More recently, diatom biozonations for the Southern Ocean have been revised to provide more detailed biochronostratigraphic resolution (Zielinski and Gersonde, 2002; Zielinski et al., 2002). We are using the most recently-revised Southern Ocean diatom-zonation schemes to systematically evaluate ages of samples taken from the base of piston cores penetrating the five individual seismically-defined units in Eastern Basin. Using this sampling strategy, we increase the chances of penetrating through the Recent hemipelagic drape to sample the underlying seismically-defined units.
Automated control and data acquisition for a tunable diode laser heterodyne spectrometer
NASA Technical Reports Server (NTRS)
Shull, T. S.; Rinsland, P. L.
1983-01-01
This paper describes the hardware and software design, development, and implementation of the control and data electronics of a laser heterodyne spectrometer instrument being built at NASA Langley Research Center for a technology demonstration. Functional partitioning, applied at all levels of hardware and software, has been found to provide expedient design, development, and testing of the instrument. The instrument is composed of distributed microprocessor-based units. A master/slave protocol is presented which can be simulated by a terminal for unit checkout. All but one of the units are implemented using a set of core boards, plus unique boards where necessary. This design has led to reduced hardware development, reduced parts inventory, and replication of software modules, while providing the flexibility needed for a development instrument. The development tools and documentation guidelines are discussed.
A Distributed Synchronization and Timing System on the EAST Tokamak
NASA Astrophysics Data System (ADS)
Luo, Jiarong; Wu, Yichun; Shu, Yantai
2008-08-01
A key requirement for the EAST distributed control system (EASTDCS) is time synchronization to an accuracy of <1 mus. In 2006 a Distributed Synchronization and Timing System (DSTS) was set up, which is based on the ATmega128 AVR microcontroller and the Nut/OS embedded Real Time Operating System (RTOS). The DSTS provides the control and the data acquisition systems with reference clocks (0.01 Hz 10 MHz) and delayed trigger times ( 1 mus 4294 s). These are produced by a Core Module Unit (CMU) connected by optical fibres to many Local Synchronized Node Units (LSNU). The fibres provide immunity from electrical noise and are of equal length to match clock and trigger delays between systems. This paper describes the architecture of the DSTS on the EAST tokamak and provides an overview of the characteristics of the main and local units.
Model based design introduction: modeling game controllers to microprocessor architectures
NASA Astrophysics Data System (ADS)
Jungwirth, Patrick; Badawy, Abdel-Hameed
2017-04-01
We present an introduction to model based design. Model based design is a visual representation, generally a block diagram, to model and incrementally develop a complex system. Model based design is a commonly used design methodology for digital signal processing, control systems, and embedded systems. Model based design's philosophy is: to solve a problem - a step at a time. The approach can be compared to a series of steps to converge to a solution. A block diagram simulation tool allows a design to be simulated with real world measurement data. For example, if an analog control system is being upgraded to a digital control system, the analog sensor input signals can be recorded. The digital control algorithm can be simulated with the real world sensor data. The output from the simulated digital control system can then be compared to the old analog based control system. Model based design can compared to Agile software develop. The Agile software development goal is to develop working software in incremental steps. Progress is measured in completed and tested code units. Progress is measured in model based design by completed and tested blocks. We present a concept for a video game controller and then use model based design to iterate the design towards a working system. We will also describe a model based design effort to develop an OS Friendly Microprocessor Architecture based on the RISC-V.
Roles of the State Asthma Program in Implementing Multicomponent, School-Based Asthma Interventions
ERIC Educational Resources Information Center
Hester, Laura L.; Wilce, Maureen A.; Gill, Sarah A.; Disler, Sheri L.; Collins, Pamela; Crawford, Gregory
2013-01-01
Background: Asthma is a leading chronic childhood disease in the United States and a major contributor to school absenteeism. Evidence suggests that multicomponent, school-based asthma interventions are a strategic way to address asthma among school-aged children. The Centers for Disease Control and Prevention (CDC) encourages the 36 health…
Neural Issues in the Control of Muscular Strength
ERIC Educational Resources Information Center
Kamen, Gary
2004-01-01
During the earliest stages of resistance exercise training, initial muscular strength gains occur too rapidly to be explained solely by muscle-based mechanisms. However, increases in surface-based EMG amplitude as well as motor unit discharge rate provide some insight to the existence of neural mechanisms in the earliest phases of resistance…
47 CFR 90.631 - Trunked systems loading, construction and authorization requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., the total number of mobile units and control stations operating in the wide-area system shall be counted with respect to the total number of base station frequencies assigned to the system. (h) Regional... fractionally over the number of base station facilities with which it communicates regularly. [47 FR 41032...
Computer Controlled Portable Greenhouse Climate Control System for Enhanced Energy Efficiency
NASA Astrophysics Data System (ADS)
Datsenko, Anthony; Myer, Steve; Petties, Albert; Hustek, Ryan; Thompson, Mark
2010-04-01
This paper discusses a student project at Kettering University focusing on the design and construction of an energy efficient greenhouse climate control system. In order to maintain acceptable temperatures and stabilize temperature fluctuations in a portable plastic greenhouse economically, a computer controlled climate control system was developed to capture and store thermal energy incident on the structure during daylight periods and release the stored thermal energy during dark periods. The thermal storage mass for the greenhouse system consisted of a water filled base unit. The heat exchanger consisted of a system of PVC tubing. The control system used a programmable LabView computer interface to meet functional specifications that minimized temperature fluctuations and recorded data during operation. The greenhouse was a portable sized unit with a 5' x 5' footprint. Control input sensors were temperature, water level, and humidity sensors and output control devices were fan actuating relays and water fill solenoid valves. A Graphical User Interface was developed to monitor the system, set control parameters, and to provide programmable data recording times and intervals.
Risk-based process safety assessment and control measures design for offshore process facilities.
Khan, Faisal I; Sadiq, Rehan; Husain, Tahir
2002-09-02
Process operation is the most hazardous activity next to the transportation and drilling operation on an offshore oil and gas (OOG) platform. Past experiences of onshore and offshore oil and gas activities have revealed that a small mis-happening in the process operation might escalate to a catastrophe. This is of especial concern in the OOG platform due to the limited space and compact geometry of the process area, less ventilation, and difficult escape routes. On an OOG platform, each extra control measure, which is implemented, not only occupies space on the platform and increases congestion but also adds extra load to the platform. Eventualities in the OOG platform process operation can be avoided through incorporating the appropriate control measures at the early design stage. In this paper, the authors describe a methodology for risk-based process safety decision making for OOG activities. The methodology is applied to various offshore process units, that is, the compressor, separators, flash drum and driers of an OOG platform. Based on the risk potential, appropriate safety measures are designed for each unit. This paper also illustrates that implementation of the designed safety measures reduces the high Fatal accident rate (FAR) values to an acceptable level.
Linn, Kristin A; Gaonkar, Bilwaj; Satterthwaite, Theodore D; Doshi, Jimit; Davatzikos, Christos; Shinohara, Russell T
2016-05-15
Normalization of feature vector values is a common practice in machine learning. Generally, each feature value is standardized to the unit hypercube or by normalizing to zero mean and unit variance. Classification decisions based on support vector machines (SVMs) or by other methods are sensitive to the specific normalization used on the features. In the context of multivariate pattern analysis using neuroimaging data, standardization effectively up- and down-weights features based on their individual variability. Since the standard approach uses the entire data set to guide the normalization, it utilizes the total variability of these features. This total variation is inevitably dependent on the amount of marginal separation between groups. Thus, such a normalization may attenuate the separability of the data in high dimensional space. In this work we propose an alternate approach that uses an estimate of the control-group standard deviation to normalize features before training. We study our proposed approach in the context of group classification using structural MRI data. We show that control-based normalization leads to better reproducibility of estimated multivariate disease patterns and improves the classifier performance in many cases. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Rice, Melissa S.; Gupta, Sanjeev; Bell, James F., III; Warner, Nicholas H.
2011-01-01
Eberswalde crater was selected as a candidate landing site for the Mars Science Laboratory (MSL) mission based on the presence of a fan-shaped sedimentary deposit interpreted as a delta. We have identified and mapped five other candidate fluvio -deltaic systems in the crater, using images and digital terrain models (DTMs) derived from the Mars Reconnaissance Orbiter (MRO) High Resolution Imaging Science Experiment (HiRISE) and Context Camera (CTX). All of these systems consist of the same three stratigraphic units: (1) an upper layered unit, conformable with (2) a subpolygonally fractured unit, unconformably overlying (3) a pitted unit. We have also mapped a system of NNE-trending scarps interpreted as dip-slip faults that pre-date the fluvial -lacustrine deposits. The post-impact regional faulting may have generated the large-scale topography within the crater, which consists of a Western Basin, an Eastern Basin, and a central high. This topography subsequently provided depositional sinks for sediment entering the crater and controlled the geomorphic pattern of delta development.
Global Thermal Power Plants Database: Unit-Based CO2, SO2, NOX and PM2.5 Emissions in 2010
NASA Astrophysics Data System (ADS)
Tong, D.; Qiang, Z.; Davis, S. J.
2016-12-01
There are more than 30,000 thermal power plants now operating worldwide, reflecting a tremendously diverse infrastructure that includes units burning oil, natural gas, coal and biomass and ranging in capacity from <1MW to >1GW. Although the electricity generated by this infrastructure is vital to economic activities across the world, it also produces more CO2 and air pollution emissions than any other industry sector. Here we present a new database of global thermal power-generating units and their emissions as of 2010, GPED (Global Power Emissions Database), including the detailed unit information of installed capacity, operation year, geographic location, fuel type and control measures for more than 70000 units. In this study, we have compiled, combined, and harmonized the available underlying data related to thermal power-generating units (e.g. eGRID of USA, CPED of China and published Indian power plants database), and then analyzed the generating capacity, capacity factor, fuel type, age, location, and installed pollution-control technology in order to determine those units with disproportionately high levels of emissions. In total, this work is of great importance for improving spatial distribution of global thermal power plants emissions and exploring their environmental impacts at global scale.
Umanodan, Rino; Shimazu, Akihito; Minami, Masahide; Kawakami, Norito
2014-01-01
This study evaluated the effectiveness of a computer-based stress management training (SMT) program in improving employees' psychological well-being and work performance. A total of 12 work units (N=263) were randomly assigned to either an intervention group (8 work units, n=142) or to a wait-list control group (4 work units, n=121). All participants were requested to answer online questionnaires assessing psychological well-being as a primary outcome, and coping style, social support, and knowledge about stress management as secondary outcomes at baseline (T0), immediately after the intervention (T1), and 2 months after the intervention (T2). The group × time interaction was tested using a mixed-model repeated measures ANOVA. Results showed a group × time interaction for "knowledge about stress management" in the entire sample. Among participants who had more than 3 d of training, a significant group × time interaction was observed for "problem-solving" and "avoidance and suppression" as well as "knowledge about stress management." Our computer-based stress management program was effective for improving knowledge about stress management. It was also effective for improving coping skills in instances where participants had enough time (at least 3 d) to complete all sessions.
Idili, Andrea
2017-01-01
Abstract DNA nanotechnology takes advantage of the predictability of DNA interactions to build complex DNA-based functional nanoscale structures. However, when DNA functional and responsive units that are based on non-canonical DNA interactions are employed it becomes quite challenging to predict, understand and control their thermodynamics. In response to this limitation, here we demonstrate the use of isothermal urea titration experiments to estimate the free energy involved in a set of DNA-based systems ranging from unimolecular DNA-based nanoswitches to more complex DNA folds (e.g. aptamers) and nanodevices. We propose here a set of fitting equations that allow to analyze the urea titration curves of these DNA responsive units based on Watson–Crick and non-canonical interactions (stem-loop, G-quadruplex, triplex structures) and to correctly estimate their relative folding and binding free energy values under different experimental conditions. The results described herein will pave the way toward the use of urea titration experiments in the field of DNA nanotechnology to achieve easier and more reliable thermodynamic characterization of DNA-based functional responsive units. More generally, our results will be of general utility to characterize other complex supramolecular systems based on different biopolymers. PMID:28605461
Microgravity induced changes in the control of motor units
NASA Astrophysics Data System (ADS)
de Luca, C.; Roy, S.
The goal of this project is to understand the effects of microgravity on the control of muscles. It is motivated by the notion that in order to adequately address microgravity-induced deterioration in the force generating capacity of muscles, one needs to understand the changes in the control aspects in addition to histochemical and morphological changes. The investigations into muscle control need to include the regulation of the firing activity of motor units that make up a muscle and the coordination of different muscles responsible for the control of a joint. In order to understand the effects of microgravity on these two aspects of muscle control, we will test astronauts before and after spaceflight. The investigations of the control of motor units will involve intramuscular EMG techniques developed in our laboratory. We will use a quadrifilar electrode to detect simultaneously three differential channels of EMG activity. These data will be decomposed accurately using a sophisticated set of algorithms constructed with artificial intelligence knowledge- based techniques. Particular attention will be paid to the firing rate and recruitment behavior of motor units and we will study the degree of cross-correlation of the firing rates. This approach will enable us to study the firing behavior of several (approx. 10) concurrently active motor units. This analysis will enable us to detect modifications in the control of motor units. We will perform these investigations in a hand muscle, which continues being used in prehensile tasks in space, and a leg muscle whose antigravity role is not needed in space. The comparison of the effects of weightlessness on these muscles will determine if continued use of muscles in space deters the possible deleterious effects of microgravity on the control of motor units, in addition to slowing down atrophy. We are particularly interested in comparing the results of this study to similar data already obtained from elderly subjects, because the deleterious effects of migrogravity on muscles is in many ways similar to that of aging. Additionally, we will employ surface EMG techniques to evaluate the effects of microgravity on the coordination of muscles controlling a joint. We will study if the relative contributions from the muscles around the knee joint are redistributed after exposure to microgravity. The insight to be gained from this study will be important in developing countermeasures for maintaining the force generating capacity of muscles in microgravity and rehabilitation programs for aiding in recovery upon return to earth.
Rasmussen, Rune Skovgaard; Østergaard, Ann; Kjær, Pia; Skerris, Anja; Skou, Christina; Christoffersen, Jane; Seest, Line Skou; Poulsen, Mai Bang; Rønholt, Finn; Overgaard, Karsten
2016-03-01
To evaluate if home-based rehabilitation of inpatients improved outcome compared to standard care. Interventional, randomised, safety/efficacy open-label trial. University hospital stroke unit in collaboration with three municipalities. Seventy-one eligible stroke patients (41 women) with focal neurological deficits hospitalised in a stroke unit for more than three days and in need of rehabilitation. Thirty-eight patients were randomised to home-based rehabilitation during hospitalization and for up to four weeks after discharge to replace part of usual treatment and rehabilitation services. Thirty-three control patients received treatment and rehabilitation following usual guidelines for the treatment of stroke patients. Ninety days post-stroke the modified Rankin Scale score was the primary endpoint. Other outcome measures were the modified Barthel-100 Index, Motor Assessment Scale, CT-50 Cognitive Test, EuroQol-5D, Body Mass Index and treatment-associated economy. Thirty-one intervention and 30 control patients completed the study. Patients in the intervention group achieved better modified Rankin Scale score (Intervention median = 2, IQR = 2-3; Control median = 3, IQR = 2-4; P=0.04). EuroQol-5D quality of life median scores were improved in intervention patients (Intervention median = 0.77, IQR = 0.66-0.79; Control median = 0.66, IQR = 0.56 - 0.72; P=0.03). The total amount of home-based training in minutes highly correlated with mRS, Barthel, Motor Assessment Scale and EuroQol-5D™ scores (P-values ranging from P<0.00001 to P=0.01). Economical estimations of intervention costs were lower than total costs of standard treatment. Early home-based rehabilitation reduced disability and increased quality of life. Compared to standard care, home-based stroke rehabilitation was more cost-effective. © The Author(s) 2015.
Intelligent fuzzy controller for event-driven real time systems
NASA Technical Reports Server (NTRS)
Grantner, Janos; Patyra, Marek; Stachowicz, Marian S.
1992-01-01
Most of the known linguistic models are essentially static, that is, time is not a parameter in describing the behavior of the object's model. In this paper we show a model for synchronous finite state machines based on fuzzy logic. Such finite state machines can be used to build both event-driven, time-varying, rule-based systems and the control unit section of a fuzzy logic computer. The architecture of a pipelined intelligent fuzzy controller is presented, and the linguistic model is represented by an overall fuzzy relation stored in a single rule memory. A VLSI integrated circuit implementation of the fuzzy controller is suggested. At a clock rate of 30 MHz, the controller can perform 3 MFLIPS on multi-dimensional fuzzy data.
Design of belt conveyor electric control device based on CC-link bus
NASA Astrophysics Data System (ADS)
Chen, Goufen; Zhan, Minhua; Li, Jiehua
2016-01-01
In view of problem of the existing coal mine belt conveyor is no field bus communication function, two levels belt conveyor electric control system design is proposed based on field bus. Two-stage belt conveyor electric control system consists of operation platform, PLC control unit, various sensors, alarm device and the water spraying device. The error protection is realized by PLC programming, made use of CC-Link bus technology, the data share and the cooperative control came true between host station and slave station. The real-time monitor was achieved by the touch screen program. Practical application shows that the system can ensure the coalmine production, and improve the automatic level of the coalmine transport equipment.
[Research of joint-robotics-based design of biomechanics testing device on human spine].
Deng, Guoyong; Tian, Lianfang; Mao, Zongyuan
2009-12-01
This paper introduces the hardware and software of a biomechanical robot-based testing device. The bottom control orders, posture and torque data transmission, and the control algorithms are integrated in a unified visual control platform by Visual C+ +, with easy control and management. By using hybrid force-displacement control method to load the human spine, we can test the organizational structure and the force state of the FSU (Functional spinal unit) well, which overcomes the shortcomings due to the separation of the force and displacement measurement, thus greatly improves the measurement accuracy. Also it is esay to identify the spinal degeneration and the load-bearing impact on the organizational structure of the FSU after various types of surgery.
The pattern of early lung parenchymal and air space injury following acute blood loss.
Younger, J G; Taqi, A S; Jost, P F; Till, G O; Johnson, K J; Stern, S A; Hirschl, R B
1998-07-01
Acute lung injury is a frequent clinical occurrence following blood loss and trauma. The nature of this injury remains poorly understood. To examine the relative parenchymal and intra-alveolar distribution of inflammation in a rat model of hemorrhage and resuscitation. Rats were anesthetized and subjected to hemorrhage followed by resuscitation with shed blood and saline. Myeloperoxidase activity of lung homogenates and cytology of bronchoalveolar lavage fluid were used to measure total lung and intra-alveolar neutrophil invasion. Extravasation of i.v.-administered [125I]-albumin was used to determine total lung and alveolar permeability. Permeability results were analyzed using their base-10 logarithmic transformations. 86 animals were studied. Whole-lung myeloperoxidase activity was increased (control = 0.34 +/- 0.16 units, injured = 0.84 +/- 0.43 units, p < 0.01), while there was no difference in intra-alveolar leukocyte counts (injured = 1.85 +/- 1.30 x 10(5)/mL, control = 2.44 +/- 1.75 x 10(5)/mL, p = 0.40), suggesting that the cellular component of the injury was more severe in the intravascular and interstitial spaces. There was a strong trend toward increased permeability in the interstitial compartment, and a significant increase in permeability in the intra-alveolar compartment (whole-lung permeability: control = -0.27 +/- 0.19 units, injured = 0.10 +/- 0.55 units, p = 0.06; alveolar permeability: control = -2.00 +/- 0.47 units, injured = -1.32 +/- 0.49 units, p < 0.01), suggesting that the loss of integrity to macromolecules was not limited to the interstitium. Hemorrhage and resuscitation resulted in an acute lung injury characterized by extravasation of intravascular protein into both the interstitium and the intra-alveolar space. Neutrophil invasion of the lung was demonstrable only in the interstitial compartment.
Bernatchez, Stéphanie F.; Ruckly, Stéphane; Timsit, Jean-François
2015-01-01
Objective To model the cost-effectiveness impact of routine use of an antimicrobial chlorhexidine gluconate-containing securement dressing compared to non-antimicrobial transparent dressings for the protection of central vascular lines in intensive care unit patients. Design This study uses a novel health economic model to estimate the cost-effectiveness of using the chlorhexidine gluconate dressing versus transparent dressings in a French intensive care unit scenario. The 30-day time non-homogeneous markovian model comprises eight health states. The probabilities of events derive from a multicentre (12 French intensive care units) randomized controlled trial. 1,000 Monte Carlo simulations of 1,000 patients per dressing strategy are used for probabilistic sensitivity analysis and 95% confidence intervals calculations. The outcome is the number of catheter-related bloodstream infections avoided. Costs of intensive care unit stay are based on a recent French multicentre study and the cost-effectiveness criterion is the cost per catheter-related bloodstream infections avoided. The incremental net monetary benefit per patient is also estimated. Patients 1000 patients per group simulated based on the source randomized controlled trial involving 1,879 adults expected to require intravascular catheterization for 48 hours. Intervention Chlorhexidine Gluconate-containing securement dressing compared to non-antimicrobial transparent dressings. Results The chlorhexidine gluconate dressing prevents 11.8 infections /1,000 patients (95% confidence interval: [3.85; 19.64]) with a number needed to treat of 85 patients. The mean cost difference per patient of €141 is not statistically significant (95% confidence interval: [€-975; €1,258]). The incremental cost-effectiveness ratio is of €12,046 per catheter-related bloodstream infection prevented, and the incremental net monetary benefit per patient is of €344.88. Conclusions According to the base case scenario, the chlorhexidine gluconate dressing is more cost-effective than the reference dressing. Trial Registration This model is based on the data from the RCT registered with www.clinicaltrials.gov (NCT01189682). PMID:26086783
ERIC Educational Resources Information Center
Shaw, Frederic E., Ed.
2008-01-01
The "Morbidity and Mortality Weekly Report" ("MMWR") Series is prepared by the Centers for Disease Control and Prevention (CDC). Data in the weekly "MMWR" are provisional, based on weekly reports to CDC by state health departments. This issue of "MMWR" contains the following studies: (1) Youth Risk Behavior…
2006-01-01
Bavari 1* 1 US Army Medical Research Institute of Infectious Diseases, Fort Detrick, Frederick, Maryland, United States of America, 2 AVI BioPharma ...used as controls in these experiments. The PMOs were synthesized by AVI BioPharma , (Corvallis, Oregon, United States), as previously described [35]. In...interests. RB, DAS, and PLI have financial interest in AVI BioPharma , the company that supplied the PMO compounds for these studies. & References 1
Siegel, Michael; DeJong, William; Albers, Alison B.; Naimi, Timothy S.; Jernigan, David H.
2012-01-01
Aims This study aims to compare the average price of liquor in the United States between retail alcohol outlets in states that have a monopoly ('control' states) with those that do not ('licence' states). Design A cross-sectional study of brand-specific alcohol prices in the United States. Setting We determined the average prices in February 2012 of 74 brands of liquor among the 13 control states that maintain a monopoly on liquor sales at the retail level and among a sample of 50 license-state liquor stores, using their online-available prices. Measurements We calculated average prices for 74 brands of liquor by control vs. license state. We used a random effects regression model to estimate differences between control and license state prices – overall and by alcoholic beverage type. We also compared prices between the 13 control states. Findings The overall mean price for the 74 brands was $27.79 in the license states (95% confidence interval [CI], $25.26–$30.32) and $29.82 in the control states (95% CI, $26.98–$32.66). Based on the random effects linear regression model, the average liquor price was approximately two dollars lower (6.9% lower) in license states. Conclusions In the United States monopoly of alcohol retail outlets appears to be associated with slightly higher liquor prices. PMID:22934914
Optimized 4-bit Quantum Reversible Arithmetic Logic Unit
NASA Astrophysics Data System (ADS)
Ayyoub, Slimani; Achour, Benslama
2017-08-01
Reversible logic has received a great attention in the recent years due to its ability to reduce the power dissipation. The main purposes of designing reversible logic are to decrease quantum cost, depth of the circuits and the number of garbage outputs. The arithmetic logic unit (ALU) is an important part of central processing unit (CPU) as the execution unit. This paper presents a complete design of a new reversible arithmetic logic unit (ALU) that can be part of a programmable reversible computing device such as a quantum computer. The proposed ALU based on a reversible low power control unit and small performance parameters full adder named double Peres gates. The presented ALU can produce the largest number (28) of arithmetic and logic functions and have the smallest number of quantum cost and delay compared with existing designs.
United States Air Force Research Initiation Program for 1988. Volume 3
1990-04-01
Assignment for Dr. Kenneth M. Sobel Flight Control Design 210-9MG-035 90 Comparative Burning Rates and Duplex Dr. Forrest Thomas (1987) Loads of Solid...Patterson Air Force Base. The test configuration has been designed for injecting fuel droplets in a well controlled laminar on well-characterized turbulent...its counter response may be significant, our system has thus achieved some measure of control over when non -critical processing is actually performed
Hao, Wei; Daniel, Janice
2014-12-01
Based on the Federal Railway Administration (FRA) database, approximately 62% of the collisions at highway-rail crossings occurred at locations with active controls (gate and flashing lights), followed by passive controls (cross bucks and stop signs) with approximately 28% of accidents. The study applied an ordered probit model to explore the determinants of driver injury severity under various control measures at highway-rail grade crossing in the United States. The analysis found that schedule factor (peak hour), visibility, motor vehicle speed, train speed, driver's age, area type, traffic volume and highway pavement impact driver injury severity at both active and passive highway-rail crossings. For both active and passive control highway-rail grade crossings, speed control for both trains and vehicles will significantly reduce driver injury severity. However, the level of influence by vehicle speed and train speed at passive control is higher compared with active control. Paving highways at highway-rail grade crossings will also help to reduce driver injury severity at highway-rail crossing accidents. Published by Elsevier Ltd.
Duchemin, Anne-Marie; Steinberg, Beth A; Marks, Donald R; Vanover, Kristin; Klatt, Maryanna
2015-04-01
To determine whether a workplace stress-reduction intervention decreases reactivity to stress among personnel exposed to a highly stressful occupational environment. Personnel from a surgical intensive care unit were randomized to a stress-reduction intervention or a waitlist control group. The 8-week group mindfulness-based intervention included mindfulness, gentle yoga, and music. Psychological and biological markers of stress were measured 1 week before and 1 week after the intervention. Levels of salivary α-amylase, an index of sympathetic activation, were significantly decreased between the first and second assessments in the intervention group with no changes in the control group. There was a positive correlation between salivary α-amylase levels and burnout scores. These data suggest that this type of intervention could decrease not only reactivity to stress but also the risk of burnout.
Wrist Camera Orientation for Effective Telerobotic Orbital Replaceable Unit (ORU) Changeout
NASA Technical Reports Server (NTRS)
Jones, Sharon Monica; Aldridge, Hal A.; Vazquez, Sixto L.
1997-01-01
The Hydraulic Manipulator Testbed (HMTB) is the kinematic replica of the Flight Telerobotic Servicer (FTS). One use of the HMTB is to evaluate advanced control techniques for accomplishing robotic maintenance tasks on board the Space Station. Most maintenance tasks involve the direct manipulation of the robot by a human operator when high-quality visual feedback is important for precise control. An experiment was conducted in the Systems Integration Branch at the Langley Research Center to compare several configurations of the manipulator wrist camera for providing visual feedback during an Orbital Replaceable Unit changeout task. Several variables were considered such as wrist camera angle, camera focal length, target location, lighting. Each study participant performed the maintenance task by using eight combinations of the variables based on a Latin square design. The results of this experiment and conclusions based on data collected are presented.
Adoption of Alcohol-Based Handrub by United States Hospitals: A National Survey
Mody, Lona; Saint, Sanjay; Kaufman, Samuel R.; Kowalski, Christine; Krein, Sarah L.
2009-01-01
The extent to which the use of alcohol-based handrub for hand hygiene has been adopted by US hospitals is unknown. A survey of infection control coordinators (response rate, 516 [72%] of 719) revealed that most hospitals (436 [84%] of 516) have adopted alcohol-based handrub. Leadership support and staff receptivity play a significant role in its adoption. PMID:18986300
The application of autostereoscopic display in smart home system based on mobile devices
NASA Astrophysics Data System (ADS)
Zhang, Yongjun; Ling, Zhi
2015-03-01
Smart home is a system to control home devices which are more and more popular in our daily life. Mobile intelligent terminals based on smart homes have been developed, make remote controlling and monitoring possible with smartphones or tablets. On the other hand, 3D stereo display technology developed rapidly in recent years. Therefore, a iPad-based smart home system adopts autostereoscopic display as the control interface is proposed to improve the userfriendliness of using experiences. In consideration of iPad's limited hardware capabilities, we introduced a 3D image synthesizing method based on parallel processing with Graphic Processing Unit (GPU) implemented it with OpenGL ES Application Programming Interface (API) library on IOS platforms for real-time autostereoscopic displaying. Compared to the traditional smart home system, the proposed system applied autostereoscopic display into smart home system's control interface enhanced the reality, user-friendliness and visual comfort of interface.
NASA Technical Reports Server (NTRS)
Fay, M.
1998-01-01
This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).
Design, construction, and testing of a five active axes magnetic bearing system
NASA Technical Reports Server (NTRS)
Delprete, Cristiana; Genta, Giancarlo; Carabelli, Stefano
1994-01-01
A high speed electric spindle based on active electromagnetic suspension technology has been designed, built, and tested. The main goal of the research work was the construction of a highly modular unit which can be used for teaching and research purposes. The design of the electromechanical components and of the control unit is described in detail, together with the characterization tests performed on the various subsystems. A description of the preliminary tests on the unit, conducted at speeds not in excess of the first deformation critical speed of the rotor, concludes the work.
NASA Technical Reports Server (NTRS)
Miller, David N.
1989-01-01
The NASA Johnson Space Center's new Multiprogram Control Center (MPCC) addresses the control requirements of complex STS payloads as well as unmanned vehicles. An account is given of the relationship of the MPCC to the STS Mission Control Center, with a view to significant difficulties that may be encountered and solutions thus far devised for generic problems. Examples of MPCC workstation applications encompass telemetry decommutation, engineering unit conversion, data-base management, trajectory processing, and flight design.
Phrenic Motor Unit Recruitment during Ventilatory and Non-Ventilatory Behaviors
Mantilla, Carlos B.; Sieck, Gary C.
2011-01-01
Phrenic motoneurons are located in the cervical spinal cord and innervate the diaphragm muscle, the main inspiratory muscle in mammals. Similar to other skeletal muscles, phrenic motoneurons and diaphragm muscle fibers form motor units which are the final element of neuromotor control. In addition to their role in sustaining ventilation, phrenic motor units are active in other non-ventilatory behaviors important for airway clearance such as coughing or sneezing. Diaphragm muscle fibers comprise all fiber types and are commonly classified based on expression of contractile proteins including myosin heavy chain isoforms. Although there are differences in contractile and fatigue properties across motor units, there is a matching of properties for the motor neuron and muscle fibers within a motor unit. Motor units are generally recruited in order such that fatigue-resistant motor units are recruited earlier and more often than more fatigable motor units. Thus, in sustaining ventilation, fatigue-resistant motor units are likely required. Based on a series of studies in cats, hamsters and rats, an orderly model of motor unit recruitment was proposed that takes into consideration the maximum forces generated by single type-identified diaphragm muscle fibers as well as the proportion of the different motor unit types. Using this model, eupnea can be accomplished by activation of only slow-twitch diaphragm motor units and only a subset of fast-twitch, fatigue-resistant units. Activation of fast-twitch fatigable motor units only becomes necessary when accomplishing tasks that require greater force generation by the diaphragm muscle, e.g., sneezing and coughing. PMID:21763470
Phrenic motor unit recruitment during ventilatory and non-ventilatory behaviors.
Mantilla, Carlos B; Sieck, Gary C
2011-10-15
Phrenic motoneurons are located in the cervical spinal cord and innervate the diaphragm muscle, the main inspiratory muscle in mammals. Similar to other skeletal muscles, phrenic motoneurons and diaphragm muscle fibers form motor units which are the final element of neuromotor control. In addition to their role in sustaining ventilation, phrenic motor units are active in other non-ventilatory behaviors important for airway clearance such as coughing or sneezing. Diaphragm muscle fibers comprise all fiber types and are commonly classified based on expression of contractile proteins including myosin heavy chain isoforms. Although there are differences in contractile and fatigue properties across motor units, there is a matching of properties for the motor neuron and muscle fibers within a motor unit. Motor units are generally recruited in order such that fatigue-resistant motor units are recruited earlier and more often than more fatigable motor units. Thus, in sustaining ventilation, fatigue-resistant motor units are likely required. Based on a series of studies in cats, hamsters and rats, an orderly model of motor unit recruitment was proposed that takes into consideration the maximum forces generated by single type-identified diaphragm muscle fibers as well as the proportion of the different motor unit types. Using this model, eupnea can be accomplished by activation of only slow-twitch diaphragm motor units and only a subset of fast-twitch, fatigue-resistant units. Activation of fast-twitch fatigable motor units only becomes necessary when accomplishing tasks that require greater force generation by the diaphragm muscle, e.g., sneezing and coughing. Copyright © 2011 Elsevier B.V. All rights reserved.
Engine speed control apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishii, M.; Miyazaki, M.; Nakamura, N.
1986-11-04
This patent describes an engine speed control apparatus. The system comprises an actuator for adjusting an engine speed, a first unit for computing a desired engine speed, a second unit for detecting the actual engine speed, and a third unit for detecting the difference between the outputs of the first and second units. The system also includes a fourth unit for computing a control pulse width for the actuator in accordance with the output of the third unit, a fifth unit for generating a control signal, a sixth unit for driving the actuator in response to the output of themore » fifth unit, and a seventh unit for computing an optimal halt time to interrupt the driving of the actuator. The actuator is driven intermittently in conformity in the control pulse width and the halt time.« less
121. VIEW OF CABINETS ON WEST SIDE OF LANDLINE INSTRUMENTATION ...
121. VIEW OF CABINETS ON WEST SIDE OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751). FEATURES LEFT TO RIGHT: FACILITY DISTRIBUTION CONSOLE FOR WATER CONTROL SYSTEMS, PROPULSION ELECTRICAL CHECKOUT SYSTEM (PECOS), LOGIC CONTROL AND MONITOR UNITS FOR BOOSTER AND FUEL SYSTEMS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Adaptive Control Responses to Behavioral Perturbation Based Upon the Insect
2006-11-01
the legs. Visual Sensors Antennal Mechanosensors Antennal Chemosensors Descending Interneurons Controlling Yaw...animals, the antenna were moved back and forth several times with servo motors to identify units that respond to antennal movement in either direction or...role of antennal postures and movements in plume tracking behavior. To date, results have shown that male moths tracking plumes in different wind
130. VIEW OF CONTROL ROOM (114), LSB (BLDG. 770), FROM ...
130. VIEW OF CONTROL ROOM (114), LSB (BLDG. 770), FROM WEST. HYDRAULIC PUMPING UNIT (HPU) IN CENTER OF PHOTO, FACING NORTH. NITROGEN SUPPLY PANEL ON SOUTH WALL (LEFT EDGE OF PHOTO); RELAY BOX FOR HPU ON SOUTH WALL BEHIND HPU. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Satisficing Decision-Making in Supervisory Control. Part 2.
1986-07-31
purpose of the United States Government. C-P Department of Mechanical Engineering Massachusetts Institute of Technology Cambridge, Massachusetts 02139...of Mechanical Engineering Massachusetts Institute of Technology Cambridge MA 02139 Satisficing Decision-Making in Supervisory Control Leonid Charny...example, that there are two attributes, speed and accuracy, and one is selecting a robot manipulator based -4n these two parameters. A set of alternatives
Dynamic Density: An Air Traffic Management Metric
NASA Technical Reports Server (NTRS)
Laudeman, I. V.; Shelden, S. G.; Branstrom, R.; Brasil, C. L.
1998-01-01
The definition of a metric of air traffic controller workload based on air traffic characteristics is essential to the development of both air traffic management automation and air traffic procedures. Dynamic density is a proposed concept for a metric that includes both traffic density (a count of aircraft in a volume of airspace) and traffic complexity (a measure of the complexity of the air traffic in a volume of airspace). It was hypothesized that a metric that includes terms that capture air traffic complexity will be a better measure of air traffic controller workload than current measures based only on traffic density. A weighted linear dynamic density function was developed and validated operationally. The proposed dynamic density function includes a traffic density term and eight traffic complexity terms. A unit-weighted dynamic density function was able to account for an average of 22% of the variance in observed controller activity not accounted for by traffic density alone. A comparative analysis of unit weights, subjective weights, and regression weights for the terms in the dynamic density equation was conducted. The best predictor of controller activity was the dynamic density equation with regression-weighted complexity terms.
Effectiveness of a community-based oral cancer awareness campaign (United States).
Papas, Rebecca K; Logan, Henrietta L; Tomar, Scott L
2004-03-01
The purpose of this study was to provide the first systematic evaluation in the United States of a community-based oral cancer awareness campaign. We used a non-equivalent control group design and random-digit-dialing methods to examine billboard effectiveness and pre- and post-billboard impact between intervention and control counties in adult probability samples in Florida, USA. Respondents in the intervention county were more likely than controls to correctly identify the billboard message to get tested for oral cancer, and less likely than controls to report ever having an oral cancer examination, or to have heard of oral cancer. Results of pre-post analyses within each county showed that oral cancer examinations were significantly more frequent in both counties after the campaign. There were no significant differences between counties on the proportion of individuals who reported having seen the campaign or on any other item measuring billboard awareness or impact. Results suggest the Florida billboard campaign had limited success in increasing public awareness. Future cancer awareness campaigns should incorporate theoretical models, target high-risk groups and the broader community and provide culturally relevant messages as part of a multi-media campaign.
NASA Astrophysics Data System (ADS)
Hill, Marc; Rizzello, Gianluca; Seelecke, Stefan
2017-08-01
Due to their many features including lightweight and low energy consumption, dielectric elastomer (DE) membrane actuators are of interest for a number of industrial applications, such as pumping systems or valve control units. In particular, the use of DEs in valve control units offers advantages over traditional solenoid valves, including lower power requirements and relative simplicity in achieving proportional control. Additionally, DEs generate low thermal dissipation and are capable of virtually silent operation. The contribution of this work is the development of a new valve system based on a circular DE membrane pre-loaded with a linear spring. The valve is designed for pressurized air and operates by actuating a lever mechanism that opens and closes an outlet port. After presenting the operating principle and system design, several experiments are presented to compare actuator force, stroke, and dissipated energy for several pressure differentials and associated volume flows. It is observed that the DE-driven valve achieves a performance similar to a solenoid-based valve, while requiring a significantly lower amount of input energy. In addition, it is shown that DE-membrane valves can be controlled proportionally by simply adjusting the actuator voltage.
Mathur, Aabhas; Chowdhury, Raquibul; Hillyer, Christopher D; Mitchell, W Beau; Shaz, Beth H
2016-12-01
Each unit of blood donated is processed and stored individually resulting in variability in the amount of red blood cells (RBCs) collected, RBC properties, and the 24-hour posttransfusion RBC survivability. As a result, each unit differs in its ability to deliver oxygen and potentially its effects on the recipient. The goal of this study was to investigate the storage of pooled RBCs from multiple donors in comparison to control standard RBC units. Two units of irradiated, leukoreduced RBCs of same ABO, D, E, C, and K antigen phenotype were collected from each of five donors using apheresis. One unit from each donor was pooled in a 2-L bag and remaining units were used as controls. After being pooled, RBCs were separated in five bags and stored at 4°C along with the controls. Quality indexes were measured on Days 2, 14, and 28 for all the units. Adenosine triphosphate assays for both pooled and controls showed a slight decrease from Day 2 to Day 28 (pooled/control from 5.22/5.24 to 4.35/4.33 µmol/g hemoglobin [Hb]). 2,3-Diphosphoglycerate was successfully rejuvenated for all RBC units on Day 28 (pooled 11.46 µmol/g Hb; control 11.86 µmol/g Hb). The results showed a nonsignificant difference between pooled and control units, with a general trend of lower standard deviation for pooled units when compared to controls. Pooled units have reduced unit-to-unit variability. Future exploration of their immunogenicity is required before using pooled units for transfusion. © 2016 AABB.
Robust gaze-steering of an active vision system against errors in the estimated parameters
NASA Astrophysics Data System (ADS)
Han, Youngmo
2015-01-01
Gaze-steering is often used to broaden the viewing range of an active vision system. Gaze-steering procedures are usually based on estimated parameters such as image position, image velocity, depth and camera calibration parameters. However, there may be uncertainties in these estimated parameters because of measurement noise and estimation errors. In this case, robust gaze-steering cannot be guaranteed. To compensate for such problems, this paper proposes a gaze-steering method based on a linear matrix inequality (LMI). In this method, we first propose a proportional derivative (PD) control scheme on the unit sphere that does not use depth parameters. This proposed PD control scheme can avoid uncertainties in the estimated depth and camera calibration parameters, as well as inconveniences in their estimation process, including the use of auxiliary feature points and highly non-linear computation. Furthermore, the control gain of the proposed PD control scheme on the unit sphere is designed using LMI such that the designed control is robust in the presence of uncertainties in the other estimated parameters, such as image position and velocity. Simulation results demonstrate that the proposed method provides a better compensation for uncertainties in the estimated parameters than the contemporary linear method and steers the gaze of the camera more steadily over time than the contemporary non-linear method.
A robust and stable PLC based control system for 40kJ/25kV EMM system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Vijay; Saroj, P.C.; Kulkarni, M.R.
2014-07-01
This paper describes the PLC based control system developed for a 40kJ/25kV Electro-magnetic machining (EMM) system. In EMM system large capacitor banks is charged with high voltage to store large energy and the banks is made to discharge into a coil within few milli-seconds using a triggered spark gaps. During discharge of the capacitor large surges and transients are generated in the system. The control system monitors/controls and interlocks all the units of the system for proper operation. The control system is the only subsystem which is electrically connected to all the low and high voltage subsystems. Care should bemore » taken at the signal interfacing with the control system to protect the control system. (author)« less
Shelton, Ann K; Freeman, Bradley D; Fish, Anne F; Bachman, Jean A; Richardson, Lloyd I
2015-03-01
Many research studies conducted today in critical care have a genomics component. Patients' surrogates asked to authorize participation in genomics research for a loved one in the intensive care unit may not be prepared to make informed decisions about a patient's participation in the research. To examine the effectiveness of a new, computer-based education module on surrogates' understanding of the process of informed consent for genomics research. A pilot study was conducted with visitors in the waiting rooms of 2 intensive care units in a Midwestern tertiary care medical center. Visitors were randomly assigned to the experimental (education module plus a sample genomics consent form; n = 65) or the control (sample genomics consent form only; n = 69) group. Participants later completed a test on informed genomics consent. Understanding the process of informed consent was greater (P = .001) in the experimental group than in the control group. Specifically, compared with the control group, the experimental group had a greater understanding of 8 of 13 elements of informed consent: intended benefits of research (P = .02), definition of surrogate consenter (P= .001), withdrawal from the study (P = .001), explanation of risk (P = .002), purpose of the institutional review board (P = .001), definition of substituted judgment (P = .03), compensation for harm (P = .001), and alternative treatments (P = .004). Computer-based education modules may be an important addition to conventional approaches for obtaining informed consent in the intensive care unit. Preparing patients' family members who may consider serving as surrogate consenters is critical to facilitating genomics research in critical care. ©2015 American Association of Critical-Care Nurses.
ERIC Educational Resources Information Center
Lewis, Catherine; Perry, Rebecca
2017-01-01
An understanding of fractions eludes many U.S. students, and research-based knowledge about fraction, such as the utility of linear representations, has not broadly influenced instruction. This randomized trial of lesson study supported by mathematical resources assigned 39 educator teams across the United States to locally managed lesson study…
NASA Astrophysics Data System (ADS)
Marulcu, Ismail; Barnett, Michael
2016-01-01
Background: Elementary Science Education is struggling with multiple challenges. National and State test results confirm the need for deeper understanding in elementary science education. Moreover, national policy statements and researchers call for increased exposure to engineering and technology in elementary science education. The basic motivation of this study is to suggest a solution to both improving elementary science education and increasing exposure to engineering and technology in it. Purpose/Hypothesis: This mixed-method study examined the impact of an engineering design-based curriculum compared to an inquiry-based curriculum on fifth graders' content learning of simple machines. We hypothesize that the LEGO-engineering design unit is as successful as the inquiry-based unit in terms of students' science content learning of simple machines. Design/Method: We used a mixed-methods approach to investigate our research questions; we compared the control and the experimental groups' scores from the tests and interviews by using Analysis of Covariance (ANCOVA) and compared each group's pre- and post-scores by using paired t-tests. Results: Our findings from the paired t-tests show that both the experimental and comparison groups significantly improved their scores from the pre-test to post-test on the multiple-choice, open-ended, and interview items. Moreover, ANCOVA results show that students in the experimental group, who learned simple machines with the design-based unit, performed significantly better on the interview questions. Conclusions: Our analyses revealed that the design-based Design a people mover: Simple machines unit was, if not better, as successful as the inquiry-based FOSS Levers and pulleys unit in terms of students' science content learning.
Kroeger, A; Ayala, C; Medina Lara, A
2002-06-01
A study of unit costs and cost components of two malaria-control strategies (house spraying and bednet impregnation with residual insecticides) was undertaken in 11 malaria-endemic states (departamentos) of Colombia, using data provided by control staff on self-administered questionnaires. The accuracy of the data was verified by personal visits, telephone conversations and complementary information from 10 other states. Allthe financial-cost components of the malaria-control operations carried out in the previous 6 months and the results of the control operations themselves (including the numbers of houses sprayed and numbers of bednets impregnated/day) were recorded. The information was stratified according to whether the target communities were 'near' or 'far away' from an operational base, the far-away communities being those that needed overnight stays by the control staff. The main variables analysed were unit costs/house treated, and annual cost/person protected. The results show that house spraying was generally more expensive for the health services than bednet impregnation. This is particularly the case in 'nearby' communities, where most of those at-risk live. In such communities, spraying one house was 7.2 times more expensive than impregnating one bednet. Even if only those sleeping under an impregnated net were assumed to be protected, the unit costs/person protected in a 'nearby' community were twice as high for house spraying than for bednet impregnation. In 'nearby' communities, where technicians could return to the operational base each evening, insecticides made up 80% of the total spraying costs and 42% of the costs of bednet impregnation. In 'far-away' communities, however, salaries and 'per diems' were the most important cost components, representing, respectively, 23% and 22% of the costs of spraying, and 34% plus 27% of the costs of impregnation. Insecticide wastage and non-use of discounts on insecticide prices (available through the national Ministry of Health) increased the overall costs considerably. The multiple uses of these cost calculations for district health managers are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The regional suitability of underground construction as a climate control technique is discussed with reference to (1) a bioclimatic analysis of long-term weather data for 29 locations in the United States to determine appropriate above ground climate control techniques, (2) a data base of synthesized ground temperatures for the coterminous United States, and (3) monthly dew point ground temperature comparisons for identifying the relative likelihood of condensation from one region to another. It is concluded that the suitability of earth tempering as a practice and of specific earth-sheltered design stereotypes varies geographically; while the subsurface almost always provides a thermalmore » advantage on its own terms when compared to above ground climatic data, it can, nonetheless, compromise the effectiveness of other, regionally more important climate control techniques. Also contained in the report are reviews of above and below ground climate mapping schemes related to human comfort and architectural design, and detailed description of a theoretical model of ground temperature, heat flow, and heat storage in the ground. Strategies of passive climate control are presented in a discussion of the building bioclimatic analysis procedure which has been applied in a computer analysis of 30 years of weather data for each of 29 locations in the United States.« less
Fall prevention in acute care hospitals: a randomized trial.
Dykes, Patricia C; Carroll, Diane L; Hurley, Ann; Lipsitz, Stuart; Benoit, Angela; Chang, Frank; Meltzer, Seth; Tsurikova, Ruslana; Zuyov, Lyubov; Middleton, Blackford
2010-11-03
Falls cause injury and death for persons of all ages, but risk of falls increases markedly with age. Hospitalization further increases risk, yet no evidence exists to support short-stay hospital-based fall prevention strategies to reduce patient falls. To investigate whether a fall prevention tool kit (FPTK) using health information technology (HIT) decreases patient falls in hospitals. Cluster randomized study conducted January 1, 2009, through June 30, 2009, comparing patient fall rates in 4 urban US hospitals in units that received usual care (4 units and 5104 patients) or the intervention (4 units and 5160 patients). The FPTK integrated existing communication and workflow patterns into the HIT application. Based on a valid fall risk assessment scale completed by a nurse, the FPTK software tailored fall prevention interventions to address patients' specific determinants of fall risk. The FPTK produced bed posters composed of brief text with an accompanying icon, patient education handouts, and plans of care, all communicating patient-specific alerts to key stakeholders. The primary outcome was patient falls per 1000 patient-days adjusted for site and patient care unit. A secondary outcome was fall-related injuries. During the 6-month intervention period, the number of patients with falls differed between control (n = 87) and intervention (n = 67) units (P=.02). Site-adjusted fall rates were significantly higher in control units (4.18 [95% confidence interval {CI}, 3.45-5.06] per 1000 patient-days) than in intervention units (3.15 [95% CI, 2.54-3.90] per 1000 patient-days; P = .04). The FPTK was found to be particularly effective with patients aged 65 years or older (adjusted rate difference, 2.08 [95% CI, 0.61-3.56] per 1000 patient-days; P = .003). No significant effect was noted in fall-related injuries. The use of a fall prevention tool kit in hospital units compared with usual care significantly reduced rate of falls. clinicaltrials.gov Identifier: NCT00675935.
Fall Prevention in Acute Care Hospitals
Dykes, Patricia C.; Carroll, Diane L.; Hurley, Ann; Lipsitz, Stuart; Benoit, Angela; Chang, Frank; Meltzer, Seth; Tsurikova, Ruslana; Zuyov, Lyubov; Middleton, Blackford
2011-01-01
Context Falls cause injury and death for persons of all ages, but risk of falls increases markedly with age. Hospitalization further increases risk, yet no evidence exists to support short-stay hospital-based fall prevention strategies to reduce patient falls. Objective To investigate whether a fall prevention tool kit (FPTK) using health information technology (HIT) decreases patient falls in hospitals. Design, Setting, and Patients Cluster randomized study conducted January 1, 2009, through June 30, 2009, comparing patient fall rates in 4 urban US hospitals in units that received usual care (4 units and 5104 patients) or the intervention (4 units and 5160 patients). Intervention The FPTK integrated existing communication and workflow patterns into the HIT application. Based on a valid fall risk assessment scale completed by a nurse, the FPTK software tailored fall prevention interventions to address patients’ specific determinants of fall risk. The FPTK produced bed posters composed of brief text with an accompanying icon, patient education handouts, and plans of care, all communicating patient-specific alerts to key stakeholders. Main Outcome Measures The primary outcome was patient falls per 1000 patient-days adjusted for site and patient care unit. A secondary outcome was fall-related injuries. Results During the 6-month intervention period, the number of patients with falls differed between control (n=87) and intervention (n=67) units (P=.02). Site-adjusted fall rates were significantly higher in control units (4.18 [95% confidence interval {CI}, 3.45-5.06] per 1000 patient-days) than in intervention units (3.15 [95% CI, 2.54-3.90] per 1000 patient-days; P=.04). The FPTK was found to be particularly effective with patients aged 65 years or older (adjusted rate difference, 2.08 [95% CI, 0.61-3.56] per 1000 patient-days; P=.003). No significant effect was noted in fall-related injuries. Conclusion The use of a fall prevention tool kit in hospital units compared with usual care significantly reduced rate of falls. PMID:21045097
The relationship between nurse staffing and failure to rescue: where does it matter most?
Talsma, AkkeNeel; Jones, Katherine; Guo, Ying; Wilson, Deleise; Campbell, Darrell A
2014-09-01
This study further expands on the relationship between nurse staffing levels and patient outcomes, in particular, failure to rescue. Many studies are based on single-site hospitals or single-year data, thus limiting the generalizations of the findings. The purpose was to evaluate in a multisite multiyear study the relationship between unit-level nurse staffing and FTR mortality, for ICU and non-ICU patients. Using administrative and actual unit level nurse staffing data, we used AHRQ 2003 Patient Safety Indicator (2003) software and matched those with the patient's discharge month. Fixed effects multilevel logistic analyses were used to take into account the hierarchical structure of the database and patient clustering within units. We controlled for patient demographics, clinical conditions, and CCS categories. The majority (94%) of cases were discharged from general care units, ICUs reported higher nurse staffing levels based on patient complexity. Expired cases were 3 years older, male, and nonwhite. For general care discharges, the relationship between RN level HPPD approached significance (P = 0.07), suggesting increased odds of higher FTR mortality with higher staffing levels. We did not observe any of the expected associations between the nurse staffing variables and FTR for either general care unit or ICU discharges. The comprehensive risk adjustments provided adequate "leveling of the playing field" to evaluate the impact of unit-based nurse staffing levels on FTR mortality. Future studies should evaluate the influence of unit environment and patient risk.
Andersen, Charlotte; Kolmos, Anne; Andersen, Kjeld; Sippel, Volkmar; Stenager, Elsebeth
2017-10-01
Clinical training in managing conflicts and preventing violence seldom contains sensory modulation (SM) as a method to de-escalate and prevent restraint and seclusion. Sensory-based interventions promote adaptive regulation of arousal and emotion. SM is a complementary approach that is associated with reduced rates of seclusion and restraint in mental healthcare, but there is need for more research in this area. Using SM to reduce restraint and seclusion in inpatient mental health care. The study included two similar psychiatric units where one unit implemented SM and one unit served as the control group. In the very beginning of the study, a staff-training program in the use of SM including assessment tools and intervention strategies was established. Data on restraint and forced medicine were sampled post the course of the year of implementation and compared with the control group. The use of belts decreased with 38% compared to the control group. The use of forced medication decreased with 46% compared to the control group. Altogether the use of physical restraint and forced medication decreased significantly with 42% (p < .05). Implementing a SM approach in mental healthcare facilities has a significant effect on the reduction of restraint and seclusion. As a part of the implementation, staff training and education in SM are crucial.
Evaluation of the effect of an intervention on the nutritional status of hospitalized patients.
Miguel Montoya, Isabel; Ortí Lucas, Rafael; Ferrer Ferrándiz, Esperanza; Martín Baena, David; Montejano Lozoya, Raimunda
2017-04-07
To compare the nutritional status of a population of hospitalized patients, divided into 2 different groups, both at admission and hospital discharge, and to assess the influence of nutritional alteration during the hospital stay. Quasi-experimental study comprising 2 groups of patients (N=581); an intervention group (n=303), in which nurses received specific training on managing care methodology, and a control group (n=278), in which nurses continued their usual dynamics. Each group was made up of 2 care units with patients from both surgical and medical specialties. patients admitted to the selected units with a minimum stay of 5 days. The sample selection was performed prospectively and consecutively after implementing the training. Of the 581 patients studied, 49.4% were women and 50.6% were men. Mean patient age was 68.29 (SD 16.23) years. In the intervention group, the odds ratio (OR) associated with good nutritional status was multiplied by 1.7 (OR=1.67) compared to the control group in the first evaluation and by 1.4 times (OR=1.43) at hospital discharge. The average stay in days was higher in the control group (13.71, SD 10.19) than in the intervention group (10.89, SD 7.49) (P<.001). The systematic methodology-based intervention in the chosen units was positive. Patients admitted to the intervention units had a lower nutritional alteration and a shorter hospital stay than those admitted to the control units. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
1996-01-01
We developed and evaluated a total toxic units modeling approach for predicting mean toxicity as measured in laboratory tests for Great Lakes sediments containing complex mixtures of environmental contaminants (e.g., polychlorinated biphenyls, polycyclic aromatic hydrocarbons, pesticides, chlorinated dioxins, and metals). The approach incorporates equilibrium partitioning and organic carbon control of bioavailability for organic contaminants and acid volatile sulfide (AVS) control for metals, and includes toxic equivalency for planar organic chemicals. A toxic unit is defined as the ratio of the estimated pore-water concentration of a contaminant to the chronic toxicity of that contaminant, as estimated by U.S. Environmental Protection Agency Ambient Water Quality Criteria (AWQC). The toxic unit models we developed assume complete additivity of contaminant effects, are completely mechanistic in form, and were evaluated without any a posteriori modification of either the models or the data from which the models were developed and against which they were tested. A linear relationship between total toxic units, which included toxicity attributable to both iron and un-ionized ammonia, accounted for about 88% of observed variability in mean toxicity; a quadratic relationship accounted for almost 94%. Exclusion of either bioavailability components (i.e., equilibrium partitioning control of organic contaminants and AVS control of metals) or iron from the model substantially decreased its ability to predict mean toxicity. A model based solely on un-ionized ammonia accounted for about 47% of the variability in mean toxicity. We found the toxic unit approach to be a viable method for assessing and ranking the relative potential toxicity of contaminated sediments.
Predicting Envelope Leakage in Attached Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faakye, O.; Arena, L.; Griffiths, D.
2013-07-01
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, andmore » control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.« less
21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...
21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...
Research on tactical information display technology for interactive virtual cockpit
NASA Astrophysics Data System (ADS)
Sun, Zhongyun; Tian, Tao; Su, Feng
2018-04-01
Based on a fact that traditional tactical information display technology suffers from disadvantages of a large number of data to be transferred and low plotting efficiency in an interactive virtual cockpit, a GID protocol-based simulation has been designed. This method dissolves complex tactical information screens into basic plotting units. The indication of plotting units is controlled via the plotting commands, which solves the incompatibility between the tactical information display in traditional simulation and the desktop-based virtual simulation training system. Having been used in desktop systems for helicopters, fighters, and transporters, this method proves to be scientific and reasonable in design and simple and efficient in usage, which exerts a significant value in establishing aviation equipment technology support training products.
[Quality control of laser imagers].
Winkelbauer, F; Ammann, M; Gerstner, N; Imhof, H
1992-11-01
Multiformat imagers based on laser systems are used for documentation in an increasing number of investigations. The specific problems of quality control are explained and the persistence of film processing in these imager systems of different configuration with (Machine 1: 3M-Laser-Imager-Plus M952 with connected 3M Film-Processor, 3M-Film IRB, X-Rax Chemical Mixer 3M-XPM, 3M-Developer and Fixer) or without (Machine 2: 3M-Laser-Imager-Plus M952 with separate DuPont-Cronex Film-processor, Kodak IR-Film, Kodak Automixer, Kodak-Developer and Fixer) connected film processing unit are investigated. In our checking based on DIN 6868 and ONORM S 5240 we found persistence of film processing in the equipment with directly adapted film processing unit according to DIN and ONORM. The checking of film persistence as demanded by DIN 6868 in these equipment could therefore be performed in longer periods. Systems with conventional darkroom processing comparatively show plain increased fluctuation, and hence the demanded daily control is essential to guarantee appropriate reaction and constant quality of documentation.
Random noise can help to improve synchronization of excimer laser pulses.
Mingesz, Róbert; Barna, Angéla; Gingl, Zoltán; Mellár, János
2016-02-01
Recently, we have reported on a compact microcontroller-based unit developed to accurately synchronize excimer laser pulses (Mingesz et al. 2012 Fluct. Noise Lett. 11, 1240007 (doi:10.1142/S021947751240007X)). We have shown that dithering based on random jitter noise plus pseudorandom numbers can be used in the digital control system to radically reduce the long-term drift of the laser pulse from the trigger and to improve the accuracy of the synchronization. In this update paper, we present our new experimental results obtained by the use of the delay-controller unit to tune the timing of a KrF excimer laser as an addition to our previous numerical simulation results. The hardware was interfaced to the laser using optical signal paths in order to reduce sensitivity to electromagnetic interference and the control algorithm tested by simulations was applied in the experiments. We have found that the system is able to reduce the delay uncertainty very close to the theoretical limit and performs well in real applications. The simple, compact and flexible system is universal enough to also be used in various multidisciplinary applications.
Testing a dissonance body image intervention among young girls.
Halliwell, Emma; Diedrichs, Phillippa C
2014-02-01
Body image and eating disorder interventions based on cognitive dissonance have been shown to be effective among girls and women aged 14 and above. This article reports a preliminary examination of whether a dissonance intervention is also effective when delivered in a school setting to 12- and 13-year-old girls in the United Kingdom. Girls (N = 106, mean age = 12.07 years, SD = .27) were allocated to the intervention condition or a waitlist control. In contrast to the control group, girls in the intervention condition reported significant reductions in body dissatisfaction and internalization of a thin body ideal post-intervention. There was no significant change in self-reported dietary restraint for either condition. In addition, compared with the control group, girls in the intervention condition showed increased resilience to negative media effects 1-month post-intervention. Results suggests that dissonance based programs can reduce body dissatisfaction, internalization and negative media effects among a younger group of girls than previously examined and in a United Kingdom school setting. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Development of a compact laser-based single photon ionization time-of-flight mass spectrometer
NASA Astrophysics Data System (ADS)
Tonokura, Kenichi; Kanno, Nozomu; Yamamoto, Yukio; Yamada, Hiroyuki
2010-02-01
We have developed a compact, laser-based, single photon ionization time-of-flight mass spectrometer (SPI-TOF-MS) for on-line monitoring of trace organic species. To obtain the mass spectrum, we use a nearly fragmentation-free SPI technique with 10.5 eV (118 nm) vacuum ultraviolet laser pulses generated by frequency tripling of the third harmonic of an Nd:YAG laser. The instrument can be operated in a linear TOF-MS mode or a reflectron TOF-MS mode in the coaxial design. We designed ion optics to optimize detection sensitivity and mass resolution. For data acquisition, the instrument is controlled using LabVIEW control software. The total power requirement for the vacuum unit, control electronics unit, ion optics, and detection system is approximately 100 W. We achieve a detection limit of parts per billion by volume (ppbv) for on-line trace analysis of several organic compounds. A mass resolution of 800 at about 100 amu is obtained for reflectron TOF-MS mode in a 0.35 m long instrument. The application of on-line monitoring of diesel engine exhaust was demonstrated.
NASA Astrophysics Data System (ADS)
Bashash, Saeid; Jalili, Nader
2007-02-01
Piezoelectrically-driven nanostagers have limited performance in a variety of feedforward and feedback positioning applications because of their nonlinear hysteretic response to input voltage. The hysteresis phenomenon is well known for its complex and multi-path behavior. To realize the underlying physics of this phenomenon and to develop an efficient compensation strategy, the intelligence properties of hysteresis with the effects of non-local memories are discussed here. Through performing a set of experiments on a piezoelectrically-driven nanostager with a high resolution capacitive position sensor, it is shown that for the precise prediction of the hysteresis path, certain memory units are required to store the previous hysteresis trajectory data. Based on the experimental observations, a constitutive memory-based mathematical modeling framework is developed and trained for the precise prediction of the hysteresis path for arbitrarily assigned input profiles. Using the inverse hysteresis model, a feedforward control strategy is then developed and implemented on the nanostager to compensate for the ever-present nonlinearity. Experimental results demonstrate that the controller remarkably eliminates the nonlinear effect, if memory units are sufficiently chosen for the inverse model.
The MSG Central Facility - A Mission Control System for Windows NT
NASA Astrophysics Data System (ADS)
Thompson, R.
The MSG Central Facility, being developed by Science Systems for EUMETSAT1, represents the first of a new generation of satellite mission control systems, based on the Windows NT operating system. The system makes use of a range of new technologies to provide an integrated environment for the planning, scheduling, control and monitoring of the entire Meteosat Second Generation mission. It supports packetised TM/TC and uses Science System's Space UNiT product to provide automated operations support at both Schedule (Timeline) and Procedure levels. Flexible access to historical data is provided through an operations archive based on ORACLE Enterprise Server, hosted on a large RAID array and off-line tape jukebox. Event driven real-time data distribution is based on the CORBA standard. Operations preparation and configuration control tools form a fully integrated element of the system.
Harland, Mark; Cust, Anne E; Badenas, Celia; Chang, Yu-Mei; Holland, Elizabeth A; Aguilera, Paula; Aitken, Joanne F; Armstrong, Bruce K; Barrett, Jennifer H; Carrera, Cristina; Chan, May; Gascoyne, Joanne; Giles, Graham G; Agha-Hamilton, Chantelle; Hopper, John L; Jenkins, Mark A; Kanetsky, Peter A; Kefford, Richard F; Kolm, Isabel; Lowery, Johanna; Malvehy, Josep; Ogbah, Zighereda; Puig-Butille, Joan-Anton; Orihuela-Segalés, Jordi; Randerson-Moor, Juliette A; Schmid, Helen; Taylor, Claire F; Whitaker, Linda; Bishop, D Timothy; Mann, Graham J; Newton-Bishop, Julia A; Puig, Susana
2014-01-01
Mutations in the CDKN2A and CDK4 genes predispose to melanoma. From three case-control studies of cutaneous melanoma, we estimated the prevalence and predictors of these mutations for people from regions with widely differing latitudes and melanoma incidence. Population-based cases and controls from the United Kingdom (1586 cases, 499 controls) and Australia (596 early-onset cases, 476 controls), and a hospital-based series from Spain (747 cases, 109 controls), were screened for variants in all exons of CDKN2A and the p16INK4A binding domain of CDK4. The prevalence of mutations for people with melanoma was similar across regions: 2.3%, 2.5% and 2.0% for Australia, Spain and the United Kingdom respectively. The strongest predictors of carrying a mutation were having multiple primaries (odds ratio (OR) = 5.4, 95% confidence interval (CI: 2.5, 11.6) for 2 primaries and OR = 32.4 (95% CI: 14.7, 71.2) for 3 or more compared with 1 primary only); and family history (OR = 3.8; 95% CI:1.89, 7.5) for 1 affected first- or second-degree relative and OR = 23.2 (95% CI: 11.3, 47.6) for 2 or more compared with no affected relatives). Only 1.1% of melanoma cases with neither a family history nor multiple primaries had mutations. There is a low probability (<2%) of detecting a germline CDKN2A mutation in people with melanoma except for those with a strong family history of melanoma (≥2 affected relatives, 25%), three or more primary melanomas (29%), or more than one primary melanoma who also have other affected relatives (27%).
Hamlet, Jason R [Albuquerque, NM; Robertson, Perry J [Albuquerque, NM; Pierson, Lyndon G [Albuquerque, NM; Olsberg, Ronald R [Albuquerque, NM
2012-02-28
A deflate decompressor includes at least one decompressor unit, a memory access controller, a feedback path, and an output buffer unit. The memory access controller is coupled to the decompressor unit via a data path and includes a data buffer to receive the data stream and temporarily buffer a first portion the data stream. The memory access controller transfers fixed length data units of the data stream from the data buffer to the decompressor unit with reference to a memory pointer pointing into the memory buffer. The feedback path couples the decompressor unit to the memory access controller to feed back decrement values to the memory access controller for updating the memory pointer. The decrement values each indicate a number of bits unused by the decompressor unit when decoding the fixed length data units. The output buffer unit buffers a second portion of the data stream after decompression.
SPRINGER, TAMAR; LOHR, NAOMI E.; BUCHTEL, HENRY A.; SILK, KENNETH R.
1996-01-01
A randomized, controlled study evaluated the effectiveness of a cognitive-behavioral therapy group, based on Linehan’s dialectical behavior therapy, for inpatients with personality disorders. The treatment, a problem-solving skills group focused on parasuicidality, was compared with a discussion control group. Change was assessed by self-report measures and behavioral observations on the unit. Subjects in both groups improved significantly on most change measures, although no significant between-group differences were found. However, the treatment group patients viewed the intervention as more beneficial to them in their lives outside the hospital. The usefulness of this type of group on a short-term unit is discussed. PMID:22700265
A portable personal cooling system for mine rescue operations
NASA Technical Reports Server (NTRS)
Webbon, B.; Williams, B.; Kirk, P.; Elkins, W.; Stein, R.
1977-01-01
Design of a portable personal cooling system to reduce physiological stress in high-temperature, high-humidity conditions is discussed. The system, based on technology used in the thermal controls of space suits, employs a combination of head and thoracic insulation and cooling through a heat sink unit. Average metabolic rates, heart rates, rectal temperature increase and sweat loss were monitored for test subjects wearing various configurations of the cooling system, as well as for a control group. The various arrangements of the cooling garment were found to provide significant physiological benefits; however, increases in heat transfer rate of the cooling unit and more effective insulation are suggested to improve the system's function.
Sommer, A; Girnus, R; Wendt, B; Czwoydzinski, J; Wüstenbecker, C; Heindel, W; Lenzen, H
2009-05-01
German breast cancer screening is monitored by a large physical quality assurance program. This report refers to the first experiences of the Reference Center (RC) Muenster after three years of the technical quality control of digital and analog mammography units (MU). This paper also shows whether the presently used quality assurance (QA) method is able to ensure that the MUs in the screening program are functioning without any serious problems. RC Muenster supervises 95 units (May 2008). The daily, weekly and monthly quality assurance of these units is controlled by web-based QA software named "MammoConrol" and developed by RC Muenster. The annual QA for the units must be conducted in the form of an on-site inspection by medical physics experts of the RC and is scored by an objective ranking system. The results of these QA routines were evaluated and analyzed for this paper. During the period from 3/1/2006 to 5/31/2008, 8 % of the analog systems and 1 % of the digital systems exhibited problems in the daily QA. For 9 % of the analog MUs and 17 % of the digital MUs, failures appeared in the monthly QA. In the annual control, 86.7 % of the analog units exhibited slight problems and 13.3 % had serious problems. With respect to the digital units, 12 % were without any defects, 58 % had slight problems, 27 % had serious failures and 3 % had to be reported to the responsible authorities and were temporarily shut down. The special quality control requirements for German breast cancer screening, including annual on-site checks of the units, have shown in the last three years that QA with a high monitoring standard can be ensured for a large number of decentralized MUs. The currently used QA method sufficiently ensures that the screening program is technically safe. Further studies must show whether the density and focus of the QA measures must be reconfigured.
System and Mass Storage Study for Defense Mapping Agency Topographic Center (DMATC/HC)
1977-04-01
34•»-—•—■»■—- view. The assessment should be based on carefully designed control condi- tions—data volume, resolution, function, etc...egories: hardware control and library management support. This software is designed to interface with IBM 360/370 OS and OS/VS. No interface with a...laser re- cording unit includes a programmable recorder control subsystem which can be designed to provide a hardware and software interface compatible
MSuPDA: A Memory Efficient Algorithm for Sequence Alignment.
Khan, Mohammad Ibrahim; Kamal, Md Sarwar; Chowdhury, Linkon
2016-03-01
Space complexity is a million dollar question in DNA sequence alignments. In this regard, memory saving under pushdown automata can help to reduce the occupied spaces in computer memory. Our proposed process is that anchor seed (AS) will be selected from given data set of nucleotide base pairs for local sequence alignment. Quick splitting techniques will separate the AS from all the DNA genome segments. Selected AS will be placed to pushdown automata's (PDA) input unit. Whole DNA genome segments will be placed into PDA's stack. AS from input unit will be matched with the DNA genome segments from stack of PDA. Match, mismatch and indel of nucleotides will be popped from the stack under the control unit of pushdown automata. During the POP operation on stack, it will free the memory cell occupied by the nucleotide base pair.
Wyman, Peter A; Henry, David; Knoblauch, Shannon; Brown, C Hendricks
2015-10-01
The dynamic wait-listed design (DWLD) and regression point displacement design (RPDD) address several challenges in evaluating group-based interventions when there is a limited number of groups. Both DWLD and RPDD utilize efficiencies that increase statistical power and can enhance balance between community needs and research priorities. The DWLD blocks on more time units than traditional wait-listed designs, thereby increasing the proportion of a study period during which intervention and control conditions can be compared, and can also improve logistics of implementing intervention across multiple sites and strengthen fidelity. We discuss DWLDs in the larger context of roll-out randomized designs and compare it with its cousin the Stepped Wedge design. The RPDD uses archival data on the population of settings from which intervention unit(s) are selected to create expected posttest scores for units receiving intervention, to which actual posttest scores are compared. High pretest-posttest correlations give the RPDD statistical power for assessing intervention impact even when one or a few settings receive intervention. RPDD works best when archival data are available over a number of years prior to and following intervention. If intervention units were not randomly selected, propensity scores can be used to control for non-random selection factors. Examples are provided of the DWLD and RPDD used to evaluate, respectively, suicide prevention training (QPR) in 32 schools and a violence prevention program (CeaseFire) in two Chicago police districts over a 10-year period. How DWLD and RPDD address common threats to internal and external validity, as well as their limitations, are discussed.
Wyman, Peter A.; Brown, C. Hendricks
2015-01-01
The dynamic wait-listed design (DWLD) and regression point displacement design (RPDD) address several challenges in evaluating group-based interventions when there is a limited number of groups. Both DWLD and RPDD utilize efficiencies that increase statistical power and can enhance balance between community needs and research priorities. The DWLD blocks on more time units than traditional wait-listed designs, thereby increasing the proportion of a study period during which intervention and control conditions can be compared, and can also improve logistics of implementing intervention across multiple sites and strengthen fidelity. We discuss DWLDs in the larger context of roll-out randomized designs and compare it with its cousin the Stepped Wedge design. The RPDD uses archival data on the population of settings from which intervention unit(s) are selected to create expected posttest scores for units receiving intervention, to which actual posttest scores are compared. High pretest-posttest correlations give the RPDD statistical power for assessing intervention impact even when one or a few settings receive intervention. RPDD works best when archival data are available over a number of years prior to and following intervention. If intervention units were not randomly selected, propensity scores can be used to control for nonrandom selection factors. Examples are provided of the DWLD and RPDD used to evaluate, respectively, suicide prevention training (QPR) in 32 schools and a violence prevention program (CeaseFire) in 2 Chicago police districts over a 10-year period. How DWLD and RPDD address common threats to internal and external validity, as well as their limitations, are discussed. PMID:25481512
Multiplex fluorescent immunoassay device based on magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Godjevargova, T. I.; Ivanov, Y. L.; Dinev, D. D.
2017-02-01
Immunofluorescent analyzer based compact disc for simultaneous detection of 3 antibiotics in the same milk sample is consisting of two parts: CD-based immunofluorescence kit and optoelectronic fluorometer. Kit consists of 2 parts: Lyophilized immobilized antibodies on supermagnetic nanoparticles in Eppendorf tubes and CD-based microfluidic disk, in which are formed five chamber systems for simultaneous detecting of 5 separate samples. Each system consists of 2 chambers connected by a special micro channel acting as a hydrophobic valve. In the first chamber lyophilised conjugates of 3 antibiotics with accordingly 3 different fluorescent dyes are placed. The second chamber is for detection of fluorescent signal. The optoelectronic fluorometer is comprising of: integrated thermostatic block; mechanical-detecting unit (fluorometer) and block with controlling and visualizing electronics.The disc gets into a second block of the analyzer, where centrifugation is performed and also reporting of the fluorescent signals. This unit comprises a rotor on which the disc is fixed, permanent electromagnet in the form of a ring inserted under the disc and module of 3 LED diodes with emission filters for the relevant wavelengths corresponding to the used fluorescent dyes and 1 integrated photodiode, in front of which is mounted filter with 3 spectral peaks.The signal from the photodiode is detected by the electronic unit which is sensitive "lock-in" amplifier, the engine rotor management, control of thermostatic device and management of periphery of the analyzer, consisting of display and communications with computer.
Dental unit waterlines disinfection using hypochlorous acid-based disinfectant
Shajahan, Irfana Fathima; Kandaswamy, D; Srikanth, Padma; Narayana, L Lakshmi; Selvarajan, R
2016-01-01
Objective: The purpose of the study was to investigate the efficacy of a new disinfectant to disinfect the dental unit waterlines. Materials and Methods: New dental unit waterlines were installed in 13 dental chairs, and biofilm was allowed to grow for 10 days. Disinfection treatment procedure was carried out in the 12 units, and one unit was left untreated. The dental unit waterlines were removed and analyzed using the scanning electron microscope (SEM) (TESCAN VEGA3 SBU). Result: On examination, SEM images showed that there was no slime layer or bacterial cells seen in any of the 12 cut sections obtained from the treated dental waterlines which mean that there was no evident of biofilm formation. Untreated dental unit waterlines showed a microbial colonization with continuous filamentous organic matrix. There was significant biofilm formation in the control tube relative to the samples. Conclusion: The tested disinfectant was found to be effective in the removal of biofilm from the dental unit waterlines. PMID:27563184
Decentralized and Modular Electrical Architecture
NASA Astrophysics Data System (ADS)
Elisabelar, Christian; Lebaratoux, Laurence
2014-08-01
This paper presents the studies made on the definition and design of a decentralized and modular electrical architecture that can be used for power distribution, active thermal control (ATC), standard inputs-outputs electrical interfaces.Traditionally implemented inside central unit like OBC or RTU, these interfaces can be dispatched in the satellite by using MicroRTU.CNES propose a similar approach of MicroRTU. The system is based on a bus called BRIO (Bus Réparti des IO), which is composed, by a power bus and a RS485 digital bus. BRIO architecture is made with several miniature terminals called BTCU (BRIO Terminal Control Unit) distributed in the spacecraft.The challenge was to design and develop the BTCU with very little volume, low consumption and low cost. The standard BTCU models are developed and qualified with a configuration dedicated to ATC, while the first flight model will fly on MICROSCOPE for PYRO actuations and analogue acquisitions. The design of the BTCU is made in order to be easily adaptable for all type of electric interface needs.Extension of this concept is envisaged for power conditioning and distribution unit, and a Modular PCDU based on BRIO concept is proposed.
NIC atomic operation unit with caching and bandwidth mitigation
Hemmert, Karl Scott; Underwood, Keith D.; Levenhagen, Michael J.
2016-03-01
A network interface controller atomic operation unit and a network interface control method comprising, in an atomic operation unit of a network interface controller, using a write-through cache and employing a rate-limiting functional unit.
NASA Astrophysics Data System (ADS)
Wahid, A.; Prasetyo, A. P.
2018-03-01
This study describes the selection of controllers in the vacuum distillation unit (VDU) between a model predictive control (MPC) and a proportional-integral (PI) controller by comparing the integral square error (ISE) values. Design of VDU in this simulation is based on modified Metso Automation Inc. scheme. Controlled variables in this study are feed flow rate, feed temperature, top stage pressure, condenser level, bottom stage temperature, LVGO (light vacuum gas oil), MVGO (medium vacuum gas oil), and HVGO (heavy vacuum gas oil) flow rate. As a result, control performance improvements occurred as using MPC compared to PI controllers, when testing a set-point change, of feed flow rate control, feed temperature, top-stage pressure, bottom-stage temperature and flow rate of LVGO, MVGO, and HVGO, respectively, 36%, 6%, 92%, 53%, 90%, 96% and 88%. Only on condenser level control PI performs much better than the MPC. So PI controller is used for level condenser control. While for the test of disturbance rejection, by changing feed flow rate by 10%, there is improvement of control performance using MPC compared to PI controller on feed temperature control, top-stage pressure, bottom-stage temperature and flow rate LVGO, MVGO and HVGO 0.3%, 0.7%, 14%, 2.7%, 10.6% and 4.3%, respectively.
NASA Technical Reports Server (NTRS)
Fijany, Amir (Inventor); Bejczy, Antal K. (Inventor)
1994-01-01
In a computer having a large number of single-instruction multiple data (SIMD) processors, each of the SIMD processors has two sets of three individual processor elements controlled by a master control unit and interconnected among a plurality of register file units where data is stored. The register files input and output data in synchronism with a minor cycle clock under control of two slave control units controlling the register file units connected to respective ones of the two sets of processor elements. Depending upon which ones of the register file units are enabled to store or transmit data during a particular minor clock cycle, the processor elements within an SIMD processor are connected in rings or in pipeline arrays, and may exchange data with the internal bus or with neighboring SIMD processors through interface units controlled by respective ones of the two slave control units.
Implementation of a Portable Personal EKG Signal Monitoring System
NASA Astrophysics Data System (ADS)
Tan, Tan-Hsu; Chang, Ching-Su; Chen, Yung-Fu; Lee, Cheng
This research develops a portable personal EKG signal monitoring system to help patients monitor their EKG signals instantly to avoid the occurrence of tragedies. This system is built with two main units: signal pro-cessing unit and monitoring and evaluation unit. The first unit consists of EKG signal sensor, signal amplifier, digitalization circuit, and related control circuits. The second unit is a software tool developed on an embedded Linux platform (called CSA). Experimental result indicates that the proposed system has the practical potential for users in health monitoring. It is demonstrated to be more convenient and with greater portability than the conventional PC-based EKG signal monitoring systems. Furthermore, all the application units embedded in the system are built with open source codes, no licensed fee is required for operating systems and authorized applications. Thus, the building cost is much lower than the traditional systems.
Daylight control system device and method
Paton, John Douglas
2007-03-13
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system, device and method
Paton, John Douglas
2012-08-28
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system device and method
Paton, John Douglas
2009-12-01
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Ground-based assessment of JAXA mouse habitat cage unit by mouse phenotypic studies.
Shimbo, Miki; Kudo, Takashi; Hamada, Michito; Jeon, Hyojung; Imamura, Yuki; Asano, Keigo; Okada, Risa; Tsunakawa, Yuki; Mizuno, Seiya; Yagami, Ken-Ichi; Ishikawa, Chihiro; Li, Haiyan; Shiga, Takashi; Ishida, Junji; Hamada, Juri; Murata, Kazuya; Ishimaru, Tomohiro; Hashimoto, Misuzu; Fukamizu, Akiyoshi; Yamane, Mutsumi; Ikawa, Masahito; Morita, Hironobu; Shinohara, Masahiro; Asahara, Hiroshi; Akiyama, Taishin; Akiyama, Nobuko; Sasanuma, Hiroki; Yoshida, Nobuaki; Zhou, Rui; Wang, Ying-Ying; Ito, Taito; Kokubu, Yuko; Noguchi, Taka-Aki K; Ishimine, Hisako; Kurisaki, Akira; Shiba, Dai; Mizuno, Hiroyasu; Shirakawa, Masaki; Ito, Naoki; Takeda, Shin; Takahashi, Satoru
2016-05-20
The Japan Aerospace Exploration Agency developed the mouse Habitat Cage Unit (HCU) for installation in the Cell Biology Experiment Facility (CBEF) onboard the Japanese Experimental Module ("Kibo") on the International Space Station. The CBEF provides "space-based controls" by generating artificial gravity in the HCU through a centrifuge, enabling a comparison of the biological consequences of microgravity and artificial gravity of 1 g on mice housed in space. Therefore, prior to the space experiment, a ground-based study to validate the habitability of the HCU is necessary to conduct space experiments using the HCU in the CBEF. Here, we investigated the ground-based effect of a 32-day housing period in the HCU breadboard model on male mice in comparison with the control cage mice. Morphology of skeletal muscle, the thymus, heart, and kidney, and the sperm function showed no critical abnormalities between the control mice and HCU mice. Slight but significant changes caused by the HCU itself were observed, including decreased body weight, increased weights of the thymus and gastrocnemius, reduced thickness of cortical bone of the femur, and several gene expressions from 11 tissues. Results suggest that the HCU provides acceptable conditions for mouse phenotypic analysis using CBEF in space, as long as its characteristic features are considered. Thus, the HCU is a feasible device for future space experiments.
Design and initial validation of a wireless control system based on WSN
NASA Astrophysics Data System (ADS)
Yu, Yan; Li, Luyu; Li, Peng; Wang, Xu; Liu, Hang; Ou, Jinping
2013-04-01
At present, cantilever structure used widely in civil structures will generate continuous vibration by external force due to their low damping characteristic, which leads to a serious impact on the working performance and service time. Therefore, it is very important to control the vibration of these structures. The active vibration control is the primary means of controlling the vibration with high precision and strong adaptive ability. Nowadays, there are many researches using piezoelectric materials in the structural vibration control. Piezoelectric materials are cheap, reliable and they can provide braking and sensing method harmless to the structure, therefore they have broad usage. They are used for structural vibration control in a lot of civil engineering research currently. In traditional sensor applications, information exchanges with the monitoring center or a computer system through wires. If wireless sensor networks(WSN) technology is used, cabling links is not needed, thus the cost of the whole system is greatly reduced. Based on the above advantages, a wireless control system is designed and validated through preliminary tests. The system consists of a cantilever, PVDF as sensor, signal conditioning circuit(SCM), A/D acquisition board, control arithmetic unit, D/A output board, power amplifier, piezoelectric bimorph as actuator. DSP chip is used as the control arithmetic unit and PD control algorithm is embedded in it. PVDF collects the parameters of vibration, sends them to the SCM after A/D conversion. SCM passes the data to the DSP through wireless technology, and DSP calculates and outputs the control values according to the control algorithm. The output signal is amplified by the power amplifier to drive the piezoelectric bimorph for vibration control. The structural vibration duration reduces to 1/4 of the uncontrolled case, which verifies the feasibility of the system.
2011-01-01
Background Crew resource management (CRM) has the potential to enhance patient safety in intensive care units (ICU) by improving the use of non-technical skills. However, CRM evaluation studies in health care are inconclusive with regard to the effect of this training on behaviour and organizational outcomes, due to weak study designs and the scarce use of direct observations. Therefore, the aim of this study is to determine the effectiveness and cost-effectiveness of CRM training on attitude, behaviour and organization after one year, using a multi-method approach and matched control units. The purpose of the present article is to describe the study protocol and the underlying choices of this evaluation study of CRM in the ICU in detail. Methods/Design Six ICUs participated in a paired controlled trial, with one pre-test and two post test measurements (respectively three months and one year after the training). Three ICUs were trained and compared to matched control ICUs. The 2-day classroom-based training was delivered to multidisciplinary groups. Typical CRM topics on the individual, team and organizational level were discussed, such as situational awareness, leadership and communication. All levels of Kirkpatrick's evaluation framework (reaction, learning, behaviour and organisation) were assessed using questionnaires, direct observations, interviews and routine ICU administration data. Discussion It is expected that the CRM training acts as a generic intervention that stimulates specific interventions. Besides effectiveness and cost-effectiveness, the assessment of the barriers and facilitators will provide insight in the implementation process of CRM. Trial registration Netherlands Trial Register (NTR): NTR1976 PMID:22073981
Kemper, Peter F; de Bruijne, Martine; van Dyck, Cathy; Wagner, Cordula
2011-11-10
Crew resource management (CRM) has the potential to enhance patient safety in intensive care units (ICU) by improving the use of non-technical skills. However, CRM evaluation studies in health care are inconclusive with regard to the effect of this training on behaviour and organizational outcomes, due to weak study designs and the scarce use of direct observations. Therefore, the aim of this study is to determine the effectiveness and cost-effectiveness of CRM training on attitude, behaviour and organization after one year, using a multi-method approach and matched control units. The purpose of the present article is to describe the study protocol and the underlying choices of this evaluation study of CRM in the ICU in detail. Six ICUs participated in a paired controlled trial, with one pre-test and two post test measurements (respectively three months and one year after the training). Three ICUs were trained and compared to matched control ICUs. The 2-day classroom-based training was delivered to multidisciplinary groups. Typical CRM topics on the individual, team and organizational level were discussed, such as situational awareness, leadership and communication. All levels of Kirkpatrick's evaluation framework (reaction, learning, behaviour and organisation) were assessed using questionnaires, direct observations, interviews and routine ICU administration data. It is expected that the CRM training acts as a generic intervention that stimulates specific interventions. Besides effectiveness and cost-effectiveness, the assessment of the barriers and facilitators will provide insight in the implementation process of CRM. Netherlands Trial Register (NTR): NTR1976.
Aziz, Imran; Palsson, Olafur S; Whitehead, William E; Sperber, Ami D; Simrén, Magnus; Törnblom, Hans
2018-05-29
Functional nausea and vomiting disorders (FNVDs) are classified as chronic nausea and vomiting syndrome (CNVS) or cyclic vomiting syndrome (CVS) - CVS includes cannabinoid hyperemesis syndrome. We investigated the population prevalence of FNVDs, their characteristics, and associated factors. In the year 2015, an Internet cross-sectional health survey was completed by 5931 adults in the general populations of 3 English-speaking countries; 2100 participants were in the United States, Canada, or the United Kingdom. Quota-based sampling was used to generate demographically balanced and population-representative samples. The survey collected data on demographics, healthcare visits, medications, somatic symptom severity, quality of life, and symptom-based diagnostic criteria for Rome IV FNVDs as well as for irritable bowel syndrome and functional dyspepsia. Subsequent comparisons were made between Rome IV FNVD subjects and individuals without FNVDs (controls). Overall, 2.2% of the population (n=131) fulfilled symptom-based diagnostic criteria for Rome IV FNVDs - the United States (3%) had a greater prevalence than Canada (1.9%) or the United Kingdom (1.8%) (P=.02). The prevalence of CNVS was similar among the countries, ranging from 0.8% to 1.2%. However, the prevalence of CVS was higher in the United States (2%) than in Canada (0.7%) or the United Kingdom (1%) (P=.03). The proportion of subjects with CVS taking cannabis did not differ significantly among countries (P=.31), although the 7 cases of cannabinoid hyperemesis syndrome were in the United States. A significantly higher proportion of subjects with CVS reported a compulsive need for hot water bathing to alleviate emetic symptoms than subjects with CNVS (44% vs. 19%, P=.03); this behaviour was independent of cannabis but augmented by its use. Subjects with FNVDs had significantly greater health impairment and health care utilization than controls. On multivariate analysis, independent factors associated with FNVDs were younger age, increasing somatic symptom severity, lower quality of life, presence of irritable bowel syndrome, and functional dyspepsia. However, on subgroup analysis, somatic symptom severity was associated with CVS but not CNVS, whereas poor quality of life was associated with CNVS but not CVS. Based on a cross-sectional health survey of adults in the general populations of 3 English-speaking countries, approximately 2% of subjects meet symptom-based criteria for Rome IV FNVDs and have considerable health impairments. Hot water bathing to alleviate emetic symptoms is reported for all FNVDs, and is perpetuated by cannabis use. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Web-Based Honorarium Confirmation System Prototype
NASA Astrophysics Data System (ADS)
Wisswani, N. W.; Catur Bawa, I. G. N. B.
2018-01-01
Improving services in academic environment can be applied by regulating salary payment process for all employees. As a form of control to maintain financial transparency, employees should have information concerning salary payment process. Currently, notification process of committee honorarium will be accepted by the employees in a manual manner. The salary will be received by the employee bank account and to know its details, they should go to the accounting unit to find out further information. Though there are some employees entering the accounting unit, they still find difficulty to obtain information about detailed honor information that they received in their accounts. This can be caused by many data collected and to be managed. Based on this issue, this research will design a prototype of web-based system for accounting unit system in order to provide detailed financial transaction confirmation to employee bank accounts that have been informed through mobile banking system. This prototype will be developed with Waterfall method through testing on final users after it is developed through PHP program with MySQL as DBMS
Distributed Economic Dispatch in Microgrids Based on Cooperative Reinforcement Learning.
Liu, Weirong; Zhuang, Peng; Liang, Hao; Peng, Jun; Huang, Zhiwu; Weirong Liu; Peng Zhuang; Hao Liang; Jun Peng; Zhiwu Huang; Liu, Weirong; Liang, Hao; Peng, Jun; Zhuang, Peng; Huang, Zhiwu
2018-06-01
Microgrids incorporated with distributed generation (DG) units and energy storage (ES) devices are expected to play more and more important roles in the future power systems. Yet, achieving efficient distributed economic dispatch in microgrids is a challenging issue due to the randomness and nonlinear characteristics of DG units and loads. This paper proposes a cooperative reinforcement learning algorithm for distributed economic dispatch in microgrids. Utilizing the learning algorithm can avoid the difficulty of stochastic modeling and high computational complexity. In the cooperative reinforcement learning algorithm, the function approximation is leveraged to deal with the large and continuous state spaces. And a diffusion strategy is incorporated to coordinate the actions of DG units and ES devices. Based on the proposed algorithm, each node in microgrids only needs to communicate with its local neighbors, without relying on any centralized controllers. Algorithm convergence is analyzed, and simulations based on real-world meteorological and load data are conducted to validate the performance of the proposed algorithm.
ERIC Educational Resources Information Center
Addley, K.; Boyd, S.; Kerr, R.; McQuillan, P.; Houdmont, J.; McCrory, M.
2014-01-01
Health risk appraisals (HRA) are a common type of workplace health promotion programme offered by American employers. In the United Kingdom, evidence of their effectiveness for promoting health behaviour change remains inconclusive. This randomized controlled trial examined the effects of two HRA interventions on lifestyle parameters, mental…
Review and Evaluation of Internal Control in the Department of the Navy.
1984-03-01
marketing Formulating adver- Controlling placement policies tising programs of advertisements Setting research Deciding on policies research projects Choosing...proper command level. with laws, regulations, treatires, and management policy. The command, base, or unit Written defintions of authorized activities...informa- tion to the members of the operating management ... Management also has a responsibility to maintain its access to the capital market and ... to
122. VIEW OF CABINETS ON WEST SIDE OF LANDLINE INSTRUMENTATION ...
122. VIEW OF CABINETS ON WEST SIDE OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751), FACING EAST. PECOS CABINET INCLUDES CONTROLS FOR PRESSURE SWITCHES, VALVES, AND PURGE; THE LOGIC AND MONITOR UNITS FOR BOOSTER AND FUEL SYSTEMS INCLUDES CONTROLS FOR MISSILE GROUND POWER AND HYDRAULICS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
EPA perspective - exposure and effects prediction and monitoring
Risk-based decisions for environmental chemicals often rely on estimates of human exposure and biological response. Biomarkers have proven a useful empirical tool for evaluating exposure and hazard predictions. In the United States, the Centers for Disease Control and Preventio...
Geographic information systems in corn rootworm management
USDA-ARS?s Scientific Manuscript database
Corn rootworms (Diabrotica spp. Coleoptera: Chrysomelidae) are serious pests of corn (Zea mays) in the United States and Europe. Control measures for corn rootworms (CRW) were historically based upon chemical pesticides and crop rotation. Pesticide use created environmental and economic concerns. In...
Churchill, Jessica L; Puca, Kathleen E; Meyer, Elizabeth; Carleton, Matthew; Anderson, Michael J
2017-06-01
Multiple studies have shown tranexamic acid (TXA) to reduce blood loss and transfusion rates in patients undergoing total knee arthroplasty (TKA). Accordingly, TXA has become a routine blood conservation agent for TKA. In contrast, ε-aminocaproic acid (EACA), a similar acting antifibrinolytic to TXA, has been less frequently used. This study evaluated whether EACA is as efficacious as TXA in reducing postoperative blood transfusion rates and compared the cost per surgery between agents. A multicenter retrospective chart review of elective unilateral TKA from April 2012 through December 2014 was performed. Five hospitals within a health care system participated. Data collected included age, gender, severity of illness score, use of antifibrinolytic and dose, red blood cell (RBC) transfusions and the number of units, and preadmission and discharge hemoglobin (Hb). Dosing of the antifibrinolytic differed based on the agent used, 5 or 10 g (based on weight) for EACA versus 1 g for TXA. The institutional acquisition cost of each antifibrinolytic was obtained and averaged over the study period. Of 2,922 primary unilateral TKA cases, 820 patients received EACA, 610 patients received TXA, and 1,492 patients received no antifibrinolytic (control group). Compared with the control group both EACA and TXA groups had significantly fewer patients transfused (EACA 2.8% [ p < 0.0001], TXA 3.2% [ p < 0.0001] vs. control 10.8%) and lower mean RBC units transfused per patient (EACA 0.05 units/patient [pt] [ p < 0.0001], TXA 0.05 units/pt [ p < 0.0001] vs. control 0.19 units/pt]. There was no difference in mean RBC units transfused per patient, percentage of patients transfused, and discharge Hb levels between the EACA and TXA groups ( p = 0.822, 0.236, and 0.322, respectively). Medication acquisition cost for EACA averaged $2.23 per surgery compared with TXA at $39.58 per surgery. Administration of EACA or TXA significantly decreased postoperative transfusion rates compared with no antifibrinolytic therapy. Utilization of EACA for unilateral TKA proved to be comparable to TXA in all studied aspects at a lower cost. The level of evidence for the study is Level 3. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Crombie, Iain K; Irvine, Linda; Williams, Brian; Sniehotta, Falko F; Petrie, Dennis; Jones, Claire; Norrie, John; Evans, Josie M M; Emslie, Carol; Rice, Peter M; Slane, Peter W; Humphris, Gerry; Ricketts, Ian W; Melson, Ambrose J; Donnan, Peter T; Hapca, Simona M; McKenzie, Andrew; Achison, Marcus
2018-06-01
To test the effectiveness of a theoretically based text-message intervention to reduce binge drinking among socially disadvantaged men. A multi-centre parallel group, pragmatic, individually randomized controlled trial. Community-based study conducted in four regions of Scotland. A total of 825 men aged 25-44 years recruited from socially disadvantaged areas who had two or more episodes of binge drinking (> 8 UK units on a single occasion) in the preceding 28 days: 411 men were randomized to the intervention and 414 to the control. A series of 112 interactive text messages was delivered by mobile phone during a 12-week period. The intervention was structured around the Health Action Process Approach, a comprehensive model which allows integration of a range of evidence-based behaviour change techniques. The control group received 89 texts on general health, with no mention of alcohol or use of behaviour change techniques. The primary outcome measure was the proportion of men consuming > 8 units on three or more occasions (in the previous 28 days) at 12 months post-intervention. The proportion of men consuming > 8 units on three or more occasions (in the previous 28 days) was 41.5% in the intervention group and 47.8% in the control group. Formal analysis showed that there was no evidence that the intervention was effective [odds ratio (OR) = 0.79, 95% confidence interval (CI) = 0.57-1.08; absolute reduction 5.7%, 95% CI = -13.3 to 1.9]. The Bayes factor for this outcome was 1.3, confirming that the results were inconclusive. The retention was high and similar in intervention (84.9%) and control (86.5%) groups. Most men in the intervention group engaged with the text messages: almost all (92%) replied to text messages and 67% replied more than 10 times. A theoretically based text-messaging intervention aimed at reducing binge drinking in disadvantaged men was not found to reduce prevalence of binge drinking at 12-month follow-up. © 2018 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.
Remote monitoring and fault recovery for FPGA-based field controllers of telescope and instruments
NASA Astrophysics Data System (ADS)
Zhu, Yuhua; Zhu, Dan; Wang, Jianing
2012-09-01
As the increasing size and more and more functions, modern telescopes have widely used the control architecture, i.e. central control unit plus field controller. FPGA-based field controller has the advantages of field programmable, which provide a great convenience for modifying software and hardware of control system. It also gives a good platform for implementation of the new control scheme. Because of multi-controlled nodes and poor working environment in scattered locations, reliability and stability of the field controller should be fully concerned. This paper mainly describes how we use the FPGA-based field controller and Ethernet remote to construct monitoring system with multi-nodes. When failure appearing, the new FPGA chip does self-recovery first in accordance with prerecovery strategies. In case of accident, remote reconstruction for the field controller can be done through network intervention if the chip is not being restored. This paper also introduces the network remote reconstruction solutions of controller, the system structure and transport protocol as well as the implementation methods. The idea of hardware and software design is given based on the FPGA. After actual operation on the large telescopes, desired results have been achieved. The improvement increases system reliability and reduces workload of maintenance, showing good application and popularization.
NASA Astrophysics Data System (ADS)
Kikuchi, Takahiro; Kubo, Ryogo
2016-08-01
In energy-efficient passive optical network (PON) systems, the increase in the queuing delays caused by the power-saving mechanism of optical network units (ONUs) is an important issue. Some researchers have proposed quality-of-service (QoS)-aware ONU cyclic sleep controllers in PON systems. We have proposed proportional (P) and proportional-derivative (PD)-based controllers to maintain the average queuing delay at a constant level regardless of the amount of downstream traffic. However, sufficient performance has not been obtained because of the sleep period limitation. In this paper, proportional-integral (PI) and proportional-integral-derivative (PID)-based controllers considering the sleep period limitation, i.e., using an anti-windup (AW) technique, are proposed to improve both the QoS and power-saving performance. Simulations confirm that the proposed controllers provide better performance than conventional controllers in terms of the average downstream queuing delay and the time occupancy of ONU active periods.
Development and acceleration of unstructured mesh-based cfd solver
NASA Astrophysics Data System (ADS)
Emelyanov, V.; Karpenko, A.; Volkov, K.
2017-06-01
The study was undertaken as part of a larger effort to establish a common computational fluid dynamics (CFD) code for simulation of internal and external flows and involves some basic validation studies. The governing equations are solved with ¦nite volume code on unstructured meshes. The computational procedure involves reconstruction of the solution in each control volume and extrapolation of the unknowns to find the flow variables on the faces of control volume, solution of Riemann problem for each face of the control volume, and evolution of the time step. The nonlinear CFD solver works in an explicit time-marching fashion, based on a three-step Runge-Kutta stepping procedure. Convergence to a steady state is accelerated by the use of geometric technique and by the application of Jacobi preconditioning for high-speed flows, with a separate low Mach number preconditioning method for use with low-speed flows. The CFD code is implemented on graphics processing units (GPUs). Speedup of solution on GPUs with respect to solution on central processing units (CPU) is compared with the use of different meshes and different methods of distribution of input data into blocks. The results obtained provide promising perspective for designing a GPU-based software framework for applications in CFD.
[Portable multi-purpose device for monitoring of physiological informations].
Tamura, T; Togawa, T
1983-05-01
Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.
Mayr, Astrid; Hinterberger, Guido; Lorenz, Ingo H; Kreidl, Peter; Mutschlechner, Wolfgang; Lass-Flörl, Cornelia
2017-04-01
An increase of extensively drug-resistant Pseudomonas aeruginosa (XDR-PA) in various clinical specimens among intensive care unit patients (n = 7) initiated an outbreak investigation consisting of patient data analyses, control of adherence to infection control guidelines, microbiologic surveys, and molecular-based studies. XDR-PA was detected in a jointly used aroma-oil nursing bottle for aromatherapy. We implemented the restriction of oil sharing among patients. Hence, the outbreak was controlled successfully. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
GBOOST: a GPU-based tool for detecting gene-gene interactions in genome-wide case control studies.
Yung, Ling Sing; Yang, Can; Wan, Xiang; Yu, Weichuan
2011-05-01
Collecting millions of genetic variations is feasible with the advanced genotyping technology. With a huge amount of genetic variations data in hand, developing efficient algorithms to carry out the gene-gene interaction analysis in a timely manner has become one of the key problems in genome-wide association studies (GWAS). Boolean operation-based screening and testing (BOOST), a recent work in GWAS, completes gene-gene interaction analysis in 2.5 days on a desktop computer. Compared with central processing units (CPUs), graphic processing units (GPUs) are highly parallel hardware and provide massive computing resources. We are, therefore, motivated to use GPUs to further speed up the analysis of gene-gene interactions. We implement the BOOST method based on a GPU framework and name it GBOOST. GBOOST achieves a 40-fold speedup compared with BOOST. It completes the analysis of Wellcome Trust Case Control Consortium Type 2 Diabetes (WTCCC T2D) genome data within 1.34 h on a desktop computer equipped with Nvidia GeForce GTX 285 display card. GBOOST code is available at http://bioinformatics.ust.hk/BOOST.html#GBOOST.
NASA Astrophysics Data System (ADS)
Hu, C. Y.
2016-12-01
The realization of quantum computers and quantum Internet requires not only quantum gates and quantum memories, but also transistors at single-photon levels to control the flow of information encoded on single photons. Single-photon transistor (SPT) is an optical transistor in the quantum limit, which uses a single photon to open or block a photonic channel. In sharp contrast to all previous SPT proposals which are based on single-photon nonlinearities, here I present a design for a high-gain and high-speed (up to THz) SPT based on a linear optical effect: giant circular birefringence induced by a single spin in a double-sided optical microcavity. A gate photon sets the spin state via projective measurement and controls the light propagation in the optical channel. This spin-cavity transistor can be directly configured as diodes, routers, DRAM units, switches, modulators, etc. Due to the duality as quantum gate and transistor, the spin-cavity unit provides a solid-state platform ideal for future Internet: a mixture of all-optical Internet with quantum Internet.
Impact of an inquiry unit on grade 4 students' science learning
NASA Astrophysics Data System (ADS)
Di Mauro, María Florencia; Furman, Melina
2016-09-01
This paper concerns the identification of teaching strategies that enhance the development of 4th grade students' experimental design skills at a public primary school in Argentina. Students' performance in the design of relevant experiments was evaluated before and after an eight-week intervention compared to a control group, as well as the persistence of this learning after eight months. The study involved a quasi-experimental longitudinal study with pre-test/post-test/delayed post-test measures, complemented with semi-structured interviews with randomly selected students. Our findings showed improvement in the experimental design skills as well as its sustainability among students working with the inquiry-based sequence. After the intervention, students were able to establish valid comparisons, propose pertinent designs and identify variables that should remain constant. Contrarily, students in the control group showed no improvement and continued to solve the posed problems based on prior beliefs. In summary, this paper shows evidence that implementing inquiry-based units involving problems set in cross-domain everyday situations that combine independent student work with teacher guidance significantly improves the development of scientific skills in real classroom contexts.
Acolet, Dominique; Jelphs, Kim; Davidson, Deborah; Peck, Edward; Clemens, Felicity; Houston, Rosie; Weindling, Michael; Lavis, John; Elbourne, Diana
2007-10-08
Gaps between research knowledge and practice have been consistently reported. Traditional ways of communicating information have limited impact on practice changes. Strategies to disseminate information need to be more interactive and based on techniques reported in systematic reviews of implementation of changes. There is a need for clarification as to which dissemination strategies work best to translate evidence into practice in neonatal units across England. The objective of this trial is to assess whether an innovative active strategy for the dissemination of neonatal research findings, recommendations, and national neonatal guidelines is more likely to lead to changes in policy and practice than the traditional (more passive) forms of dissemination in England. Cluster randomised controlled trial of all neonatal units in England (randomised by hospital, n = 182 and stratified by neonatal regional networks and neonatal units level of care) to assess the relative effectiveness of active dissemination strategies on changes in local policies and practices. Participants will be mainly consultant lead clinicians in each unit. The intervention will be multifaceted using: audit and feedback; educational meetings for local staff (evidence-based lectures on selected topics, interactive workshop to examine current practice and draw up plans for change); and quality improvement and organisational changes methods. Policies and practice outcomes for the babies involved will be collected before and after the intervention. Outcomes will assess all premature babies born in England during a three month period for timing of surfactant administration at birth, temperature control at birth, and resuscitation team (qualification and numbers) present at birth.
Method and Apparatus for Improved Spatial Light Modulation
NASA Technical Reports Server (NTRS)
Soutar, Colin (Inventor); Juday, Richard D. (Inventor)
2000-01-01
A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain the optical processing objective.
Method and Apparatus for Improved Spatial Light Modulation
NASA Technical Reports Server (NTRS)
Colin, Soutar (Inventor); Juday, Richard D. (Inventor)
1999-01-01
A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain die optical processing objective.
NASA Astrophysics Data System (ADS)
Murthy, Ch; MIEEE; Mohanta, D. K.; SMIEE; Meher, Mahendra
2017-08-01
Continuous monitoring and control of the power system is essential for its healthy operation. This can be achieved by making the system observable as well as controllable. Many efforts have been made by several researchers to make the system observable by placing the Phasor Measurement Units (PMUs) at the optimal locations. But so far the idea of controllability with PMUs is not considered. This paper contributes how to check whether the system is controllable or not, if not then how make it controllable using a clustering approach. IEEE 14 bus system is considered to illustrate the concept of controllability.
ERIC Educational Resources Information Center
Haag, Brenda Bannan; Grabowski, Barbara L.
The purpose of this exploratory study was to examine the effectiveness of learner manipulation of visuals with and without organizing cues in computer-based instruction on adults' factual, conceptual, and problem-solving learning. An instructional unit involving the physiology and the anatomy of the heart was used. A post-test only control group…
ERIC Educational Resources Information Center
Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Colonna, Fabio; Buonocunto, Francesca; Sacco, Valentina; Megna, Marisa; Oliva, Doretta
2012-01-01
This study assessed microswitch-based technology to enable three post-coma adults, who had emerged from a minimally conscious state but presented motor and communication disabilities, to operate a radio device. The material involved a modified radio device, a microprocessor-based electronic control unit, a personal microswitch, and an amplified…
Validation of a New Conceptual Model of School Connectedness and Its Assessment Measure
ERIC Educational Resources Information Center
Hirao, Katsura
2011-01-01
A self-report assessment scale of school connectedness was validated in this study based on the data from middle-school children in a northeastern state of the United States (n = 145). The scale was based on the School Bonding Model (Morita, 1991), which was derived reductively from the social control (bond) theory (Hirschi, 1969). This validation…
The Effect of Brain Based Instruction on Student Achievement in Algebra I
ERIC Educational Resources Information Center
Vass, Melissa G.
2010-01-01
This quantitative quasi-experimental study examined the effect of brain-based instruction compared to teacher-centered instruction on student achievement in algebra I. A pre-test and post-test were given to a control group of 30 and experimental group of 42 before and after a unit if study in algebra I, which was taught using the two instructional…
Experience of Data Handling with IPPM Payload
NASA Astrophysics Data System (ADS)
Errico, Walter; Tosi, Pietro; Ilstad, Jorgen; Jameux, David; Viviani, Riccardo; Collantoni, Daniele
2010-08-01
A simplified On-Board Data Handling system has been developed by CAEN AURELIA SPACE and ABSTRAQT as PUS-over-SpaceWire demonstration platform for the Onboard Payload Data Processing laboratory at ESTEC. The system is composed of three Leon2-based IPPM (Integrated Payload Processing Module) computers that play the roles of Instrument, Payload Data Handling Unit and Satellite Management Unit. Two PCs complete the test set-up simulating an external Memory Management Unit and the Ground Control Unit. Communication among units take place primarily through SpaceWire links; RMAP[2] protocol is used for configuration and housekeeping. A limited implementation of ECSS-E-70-41B Packet Utilisation Standard (PUS)[1] over CANbus and MIL-STD-1553B has been also realized. The Open Source RTEMS is running on the IPPM AT697E CPU as real-time operating system.
Feed-forward motor control of ultrafast, ballistic movements.
Kagaya, K; Patek, S N
2016-02-01
To circumvent the limits of muscle, ultrafast movements achieve high power through the use of springs and latches. The time scale of these movements is too short for control through typical neuromuscular mechanisms, thus ultrafast movements are either invariant or controlled prior to movement. We tested whether mantis shrimp (Stomatopoda: Neogonodactylus bredini) vary their ultrafast smashing strikes and, if so, how this control is achieved prior to movement. We collected high-speed images of strike mechanics and electromyograms of the extensor and flexor muscles that control spring compression and latch release. During spring compression, lateral extensor and flexor units were co-activated. The strike initiated several milliseconds after the flexor units ceased, suggesting that flexor activity prevents spring release and determines the timing of strike initiation. We used linear mixed models and Akaike's information criterion to serially evaluate multiple hypotheses for control mechanisms. We found that variation in spring compression and strike angular velocity were statistically explained by spike activity of the extensor muscle. The results show that mantis shrimp can generate kinematically variable strikes and that their kinematics can be changed through adjustments to motor activity prior to the movement, thus supporting an upstream, central-nervous-system-based control of ultrafast movement. Based on these and other findings, we present a shishiodoshi model that illustrates alternative models of control in biological ballistic systems. The discovery of feed-forward control in mantis shrimp sets the stage for the assessment of targets, strategic variation in kinematics and the role of learning in ultrafast animals. © 2016. Published by The Company of Biologists Ltd.
Krull, Ivy; Lundgren, Lena; Beltrame, Clelia
2014-01-01
Research studies have identified addiction treatment staff who have higher levels of education as having more positive attitudes about evidence-based treatment practices, science-based training, and the usefulness of evidence-based practices. This study examined associations between addiction treatment staff level of education and their perceptions of 3 measures of organizational change: organizational stress, training resources and staffing resources in their treatment unit. The sample included 588 clinical staff from community-based substance abuse treatment organizations who received Substance Abuse and Mental Health Services Administration (SAMHSA) funding (2003-2008) to implement evidence-based practices (EBPs). Bivariate analysis and regression modeling methods examined the relationship between staff education level (no high school education, high school education, some college, associate's degree, bachelor's degree, master's degree, doctoral degree, and other type of degree such as medical assistant, registered nurse [RN], or postdoctoral) and attitudes about organizational climate (stress), training resources, and staffing resources while controlling for staff and treatment unit characteristics. Multivariable models identified staff with lower levels of education as having significantly more positive attitudes about their unit's organizational capacity. These results contradict findings that addiction treatment staff with higher levels of education work in units with greater levels of organizational readiness for change. It cannot be inferred that higher levels of education among treatment staff is necessarily associated with high levels of organizational readiness for change.
Maximizing the Functional Status of Geriatric Patients in an Acute Community Hospital Setting.
ERIC Educational Resources Information Center
Meissner, Paul; And Others
1989-01-01
Compared patients (N=103) admitted to inpatient geriatric care unit focusing on restoration of functional status to control-unit patients (N=75). Found greater improvement in basic functional capabilities of study-unit than control-unit patients. Found mixed picture when length of stay and total charges of study- and control-unit patients were…
NASA Technical Reports Server (NTRS)
Mielke, Roland V. (Inventor); Stoughton, John W. (Inventor)
1990-01-01
Computationally complex primitive operations of an algorithm are executed concurrently in a plurality of functional units under the control of an assignment manager. The algorithm is preferably defined as a computationally marked graph contianing data status edges (paths) corresponding to each of the data flow edges. The assignment manager assigns primitive operations to the functional units and monitors completion of the primitive operations to determine data availability using the computational marked graph of the algorithm. All data accessing of the primitive operations is performed by the functional units independently of the assignment manager.
Loftus, Kelli; Tilley, Terry; Hoffman, Jason; Bradburn, Eric; Harvey, Ellen
2015-01-01
The creation of a consistent culture of safety and quality in an intensive care unit is challenging. We applied the Six Sigma Define-Measure-Analyze-Improve-Control (DMAIC) model for quality improvement (QI) to develop a long-term solution to improve outcomes in a high-risk neurotrauma intensive care unit. We sought to reduce central line utilization as a cornerstone in preventing central line-associated bloodstream infections (CLABSIs). This study describes the successful application of the DMAIC model in the creation and implementation of evidence-based quality improvement designed to reduce CLABSIs to below national benchmarks.
Fitzpatrick, Christopher; Fleming, Fiona M.; Madin-Warburton, Matthew; Schneider, Timm; Meheus, Filip; Asiedu, Kingsley; Solomon, Anthony W.; Montresor, Antonio; Biswas, Gautam
2016-01-01
Background Advocacy around mass treatment for the elimination of selected Neglected Tropical Diseases (NTDs) has typically put the cost per person treated at less than US$ 0.50. Whilst useful for advocacy, the focus on a single number misrepresents the complexity of delivering “free” donated medicines to about a billion people across the world. We perform a literature review and meta-regression of the cost per person per round of mass treatment against NTDs. We develop a web-based software application (https://healthy.shinyapps.io/benchmark/) to calculate setting-specific unit costs against which programme budgets and expenditures or results-based pay-outs can be benchmarked. Methods We reviewed costing studies of mass treatment for the control, elimination or eradication of lymphatic filariasis, schistosomiasis, soil-transmitted helminthiasis, onchocerciasis, trachoma and yaws. These are the main 6 NTDs for which mass treatment is recommended. We extracted financial and economic unit costs, adjusted to a standard definition and base year. We regressed unit costs on the number of people treated and other explanatory variables. Regression results were used to “predict” country-specific unit cost benchmarks. Results We reviewed 56 costing studies and included in the meta-regression 34 studies from 23 countries and 91 sites. Unit costs were found to be very sensitive to economies of scale, and the decision of whether or not to use local volunteers. Financial unit costs are expected to be less than 2015 US$ 0.50 in most countries for programmes that treat 100 thousand people or more. However, for smaller programmes, including those in the “last mile”, or those that cannot rely on local volunteers, both economic and financial unit costs are expected to be higher. Discussion The available evidence confirms that mass treatment offers a low cost public health intervention on the path towards universal health coverage. However, more costing studies focussed on elimination are needed. Unit cost benchmarks can help in monitoring value for money in programme plans, budgets and accounts, or in setting a reasonable pay-out for results-based financing mechanisms. PMID:27918573
Fitzpatrick, Christopher; Fleming, Fiona M; Madin-Warburton, Matthew; Schneider, Timm; Meheus, Filip; Asiedu, Kingsley; Solomon, Anthony W; Montresor, Antonio; Biswas, Gautam
2016-12-01
Advocacy around mass treatment for the elimination of selected Neglected Tropical Diseases (NTDs) has typically put the cost per person treated at less than US$ 0.50. Whilst useful for advocacy, the focus on a single number misrepresents the complexity of delivering "free" donated medicines to about a billion people across the world. We perform a literature review and meta-regression of the cost per person per round of mass treatment against NTDs. We develop a web-based software application (https://healthy.shinyapps.io/benchmark/) to calculate setting-specific unit costs against which programme budgets and expenditures or results-based pay-outs can be benchmarked. We reviewed costing studies of mass treatment for the control, elimination or eradication of lymphatic filariasis, schistosomiasis, soil-transmitted helminthiasis, onchocerciasis, trachoma and yaws. These are the main 6 NTDs for which mass treatment is recommended. We extracted financial and economic unit costs, adjusted to a standard definition and base year. We regressed unit costs on the number of people treated and other explanatory variables. Regression results were used to "predict" country-specific unit cost benchmarks. We reviewed 56 costing studies and included in the meta-regression 34 studies from 23 countries and 91 sites. Unit costs were found to be very sensitive to economies of scale, and the decision of whether or not to use local volunteers. Financial unit costs are expected to be less than 2015 US$ 0.50 in most countries for programmes that treat 100 thousand people or more. However, for smaller programmes, including those in the "last mile", or those that cannot rely on local volunteers, both economic and financial unit costs are expected to be higher. The available evidence confirms that mass treatment offers a low cost public health intervention on the path towards universal health coverage. However, more costing studies focussed on elimination are needed. Unit cost benchmarks can help in monitoring value for money in programme plans, budgets and accounts, or in setting a reasonable pay-out for results-based financing mechanisms.
Tian, Zhen; Yuan, Jingqi; Zhang, Xiang; Kong, Lei; Wang, Jingcheng
2018-05-01
The coordinated control system (CCS) serves as an important role in load regulation, efficiency optimization and pollutant reduction for coal-fired power plants. The CCS faces with tough challenges, such as the wide-range load variation, various uncertainties and constraints. This paper aims to improve the load tacking ability and robustness for boiler-turbine units under wide-range operation. To capture the key dynamics of the ultra-supercritical boiler-turbine system, a nonlinear control-oriented model is developed based on mechanism analysis and model reduction techniques, which is validated with the history operation data of a real 1000 MW unit. To simultaneously address the issues of uncertainties and input constraints, a discrete-time sliding mode predictive controller (SMPC) is designed with the dual-mode control law. Moreover, the input-to-state stability and robustness of the closed-loop system are proved. Simulation results are presented to illustrate the effectiveness of the proposed control scheme, which achieves good tracking performance, disturbance rejection ability and compatibility to input constraints. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
1983-01-01
The process technology for the manufacture of semiconductor-grade silicon in a large commercial plant by 1986, at a price less than $14 per kilogram of silicon based on 1975 dollars is discussed. The engineering design, installation, checkout, and operation of an Experimental Process System Development unit was discussed. Quality control of scaling-up the process and an economic analysis of product and production costs are discussed.
Quantum memory on a charge qubit in an optical microresonator
NASA Astrophysics Data System (ADS)
Tsukanov, A. V.
2017-10-01
A quantum-memory unit scheme on the base of a semiconductor structure with quantum dots is proposed. The unit includes a microresonator with single and double quantum dots performing frequencyconverter and charge-qubit functions, respectively. The writing process is carried out in several stages and it is controlled by optical fields of the resonator and laser. It is shown that, to achieve high writing probability, it is necessary to use high-Q resonators and to be able to suppress relaxation processes in quantum dots.
Klauser, Benedikt; Rehm, Charlotte; Summerer, Daniel; Hartig, Jörg S
2015-01-01
Synthetic RNA-based switches are a growing class of genetic controllers applied in synthetic biology to engineer cellular functions. In this chapter, we detail a protocol for the selection of posttranscriptional controllers of gene expression in yeast using the Schistosoma mansoni hammerhead ribozyme as a central catalytic unit. Incorporation of a small molecule-sensing aptamer domain into the ribozyme renders its activity ligand-dependent. Aptazymes display numerous advantages over conventional protein-based transcriptional controllers, namely, the use of little genomic space for encryption, their modular architecture allowing for easy reprogramming to new inputs, the physical linkage to the message to be controlled, and the ability to function without protein cofactors. Herein, we describe the method to select ribozyme-based switches of gene expression in Saccharomyces cerevisiae that we successfully implemented to engineer neomycin- and theophylline-responsive switches. We also highlight how to adapt the protocol to screen for switches responsive to other ligands. Reprogramming of the sensor unit and incorporation into any RNA of interest enables the fulfillment of a variety of regulatory functions. However, proper functioning of the aptazyme is largely dependent on optimal connection between the aptamer and the catalytic core. We obtained functional switches from a pool of variants carrying randomized connection sequences by an in vivo selection in MaV203 yeast cells that allows screening of a large sequence space of up to 1×10(9) variants. The protocol given explains how to construct aptazyme libraries, carry out the in vivo selection and characterize novel ON- and OFF-switches. © 2015 Elsevier Inc. All rights reserved.
Enhancing Carbon Reactivity in Mercury Control in Lignite-Fired Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chad Wocken; Michael Holmes; John Pavlish
2008-06-30
This project was awarded through the U.S. Department of Energy (DOE) National Energy Technology Laboratory Program Solicitation DE-PS26-03NT41718-01. The Energy & Environmental Research Center (EERC) led a consortium-based effort to resolve mercury (Hg) control issues facing the lignite industry. The EERC team-the Electric Power Research Institute (EPRI); the URS Corporation; the Babcock & Wilcox Company; ADA-ES; Apogee; Basin Electric Power Cooperative; Otter Tail Power Company; Great River Energy; Texas Utilities; Montana-Dakota Utilities Co.; Minnkota Power Cooperative, Inc.; BNI Coal Ltd.; Dakota Westmoreland Corporation; the North American Coal Corporation; SaskPower; and the North Dakota Industrial Commission-demonstrated technologies that substantially enhanced themore » effectiveness of carbon sorbents to remove Hg from western fuel combustion gases and achieve a high level ({ge} 55% Hg removal) of cost-effective control. The results of this effort are applicable to virtually all utilities burning lignite and subbituminous coals in the United States and Canada. The enhancement processes were previously proven in pilot-scale and limited full-scale tests. Additional optimization testing continues on these enhancements. These four units included three lignite-fired units: Leland Olds Station Unit 1 (LOS1) and Stanton Station Unit 10 (SS10) near Stanton and Antelope Valley Station Unit 1 (AVS1) near Beulah and a subbituminous Powder River Basin (PRB)-fired unit: Stanton Station Unit 1 (SS1). This project was one of three conducted by the consortium under the DOE mercury program to systematically test Hg control technologies available for utilities burning lignite. The overall objective of the three projects was to field-test and verify options that may be applied cost-effectively by the lignite industry to reduce Hg emissions. The EERC, URS, and other team members tested sorbent injection technologies for plants equipped with electrostatic precipitators (ESPs) and spray dryer absorbers combined with fabric filters (SDAs-FFs). The work focused on technology commercialization by involving industry and emphasizing the communication of results to vendors and utilities throughout the project.« less
Personnel Security Research - Prescreening and Background Investigations
1986-06-01
military unit, base, station, ship, or aircraft nf a controlled substance with the intent to distribute. Hallucinogens/ Psychedelics . A group of...and psychedelic amphetamine variants (STP, MDA). Although a unique drug, for purposes of this certificate phencyclidine (PCP) will be labeled in this
The hybrid UNIX controller for real-time data acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huesman, R.H.; Klein, G.J.; Fleming, T.K.
1996-06-01
The authors describe a hybrid data acquisition architecture integrating a conventional UNIX workstation with CAMAC-based real-time hardware. The system combines the high-level programming simplicity and user interface of a UNIX workstation with the low-level timing control available from conventional real-time hardware. They detail this architecture as it has been implemented for control of the Donner 600-Crystal Positron Tomograph (PET600). Low-level data acquisition is carried out in this system using eight LeCroy 3588 histogrammers, which together after derandomization, acquire events at rates up to 4 MHz, and two dedicated Motorola 6809 microprocessors, which arbitrate fine timing control during acquisition. A SUNmore » Microsystems UNIX workstation is used for high-level control, allowing an easily extensible user interface in an X-Windows environment, as well as real-time communications to the low-level acquisition units. Communication between the high- and low-level units is carried out via a Jorway 73A SCSI-CAMAC crate controller and a serial interface. For this application, the hybrid configuration segments low from high-level control for ease of maintenance and provided a low-cost upgrade from dated high-level control hardware.« less
NASA Astrophysics Data System (ADS)
Zhang, Chongfu; Xiao, Nengwu; Chen, Chen; Yuan, Weicheng; Qiu, Kun
2016-02-01
We propose an energy-efficient orthogonal frequency division multiplexing-based passive optical network (OFDM-PON) using adaptive sleep-mode control and dynamic bandwidth allocation. In this scheme, a bidirectional-centralized algorithm named the receiver and transmitter accurate sleep control and dynamic bandwidth allocation (RTASC-DBA), which has an overall bandwidth scheduling policy, is employed to enhance the energy efficiency of the OFDM-PON. The RTASC-DBA algorithm is used in an optical line terminal (OLT) to control the sleep mode of an optical network unit (ONU) sleep and guarantee the quality of service of different services of the OFDM-PON. The obtained results show that, by using the proposed scheme, the average power consumption of the ONU is reduced by ˜40% when the normalized ONU load is less than 80%, compared with the average power consumption without using the proposed scheme.
A Glucose Biosensor Using CMOS Potentiostat and Vertically Aligned Carbon Nanofibers.
Al Mamun, Khandaker A; Islam, Syed K; Hensley, Dale K; McFarlane, Nicole
2016-08-01
This paper reports a linear, low power, and compact CMOS based potentiostat for vertically aligned carbon nanofibers (VACNF) based amperometric glucose sensors. The CMOS based potentiostat consists of a single-ended potential control unit, a low noise common gate difference-differential pair transimpedance amplifier and a low power VCO. The potentiostat current measuring unit can detect electrochemical current ranging from 500 nA to 7 [Formula: see text] from the VACNF working electrodes with high degree of linearity. This current corresponds to a range of glucose, which depends on the fiber forest density. The potentiostat consumes 71.7 [Formula: see text] of power from a 1.8 V supply and occupies 0.017 [Formula: see text] of chip area realized in a 0.18 [Formula: see text] standard CMOS process.
28 CFR 541.41 - Institutional referral.
Code of Federal Regulations, 2010 CFR
2010-07-01
... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.41 Institutional referral. (a) The Warden shall submit a recommendation for referral of an inmate for placement in a control unit to... following factors in a recommendation for control unit placement. (1) Any incident during confinement in...
NASA Technical Reports Server (NTRS)
McMillin, Summer D.; Broerman, Craig D.; Swickrath, Michael; Anderson, Molly
2011-01-01
A principal concern for extravehicular activity (EVA) spacesuits is the capability to control carbon dioxide (CO2) and humidity (H2O) for the crewmember. The release of CO2 in a confined or unventilated area is dangerous for human health and leads to asphyxiation; therefore, CO2 and H2O control become leading factors in the design and development of the spacesuit. An amine-based CO2 and H2O vapor sorbent for use in pressure-swing regenerable beds has been developed by Hamilton Sundstrand. The application of solidamine materials with vacuum swing adsorption technology has shown the capacity to concurrently manage CO2 and H2O levels through a fully regenerative cycle eliminating mission constraints imposed with nonregenerative technologies. Two prototype solid amine-based systems, known as rapid cycle amine (RCA), were designed to continuously remove CO2 and H2O vapor from a flowing ventilation stream through the use of a two-bed amine based, vacuum-swing adsorption system. The Engineering and Science Contract Group (ESCG) RCA implements radial flow paths, whereas the Hamilton Sundstrand RCA was designed with linear flow paths. Testing was performed in a sea-level pressure environment and a reduced-pressure environment with simulated human metabolic loads in a closed-loop configuration. This paper presents the experimental results of laboratory testing for a full-size and a sub-scale test article. The testing described here characterized and evaluated the performance of each RCA unit at the required Portable Life Support Subsystem (PLSS) operating conditions. The test points simulated a range of crewmember metabolic rates. The experimental results demonstrated the ability of each RCA unit to sufficiently remove CO2 and H2O from a closed loop ambient or sub-ambient atmosphere.
Attitudes towards fever amongst UK paediatric intensive care staff.
Brick, Thomas; Agbeko, Rachel S; Davies, Patrick; Davis, Peter J; Deep, Akash; Fortune, Peter-Marc; Inwald, David P; Jones, Amy; Levin, Richard; Morris, Kevin P; Pappachan, John; Ray, Samiran; Tibby, Shane M; Tume, Lyvonne N; Peters, Mark J
2017-03-01
The role played by fever in the outcome of critical illness in children is unclear. This survey of medical and nursing staff in 35 paediatric intensive care units and transport teams in the United Kingdom and Ireland established attitudes towards the management of children with fever. Four hundred sixty-two medical and nursing staff responded to a web-based survey request. Respondents answered eight questions regarding thresholds for temperature control in usual clinical practice, indications for paracetamol use, and readiness to participate in a clinical trial of permissive temperature control. The median reported threshold for treating fever in clinical practice was 38 °C (IQR 38-38.5 °C). Paracetamol was reported to be used as an analgesic and antipyretic but also for non-specific comfort indications. There was a widespread support for a clinical trial of a permissive versus a conservative approach to fever in paediatric intensive care units. Within a trial, 58% of the respondents considered a temperature of 39 °C acceptable without treatment. Staff on paediatric intensive care units in the United Kingdom and Ireland tends to treat temperatures within the febrile range. There was a willingness to conduct a randomized controlled trial of treatment of fever. What is known: • The effect of fever on the outcome in paediatric critical illness is unknown. • Paediatricians have traditionally been reluctant to allow fever in sick children. What is new: • Paediatric intensive care staff report a tendency towards treating fever, with a median reported treatment threshold of 38 °C. • There is widespread support amongst PICU staff in the UK for a randomized controlled trial of temperature in critically ill children. • Within a trial setting, PICU staff attitudes to fever are more permissive than in clinical practice.
ISO 9001 in a neonatal intensive care unit (NICU).
Vitner, Gad; Nadir, Erez; Feldman, Michael; Yurman, Shmuel
2011-01-01
The aim of this paper is to present the process for approving and certifying a neonatal intensive care unit to ISO 9001 standards. The process started with the department head's decision to improve services quality before deciding to achieve ISO 9001 certification. Department processes were mapped and quality management mechanisms were developed. Process control and performance measurements were defined and implemented to monitor the daily work. A service satisfaction review was conducted to get feedback from families. In total, 28 processes and related work instructions were defined. Process yields showed service improvements. Family satisfaction improved. The paper is based on preparing only one neonatal intensive care unit to the ISO 9001 standard. The case study should act as an incentive for hospital managers aiming to improve service quality based on the ISO 9001 standard. ISO 9001 is becoming a recommended tool to improve clinical service quality.
Metalenses based on the non-parallel double-slit arrays
NASA Astrophysics Data System (ADS)
Shao, Hongyan; Chen, Chen; Wang, Jicheng; Pan, Liang; Sang, Tian
2017-09-01
Metalenses based on surface plasmon polaritons have played an indispensable role in ultra-thin devices designing. The amplitude, phase and polarization of electromagnetic waves all can be controlled easily by modifying the metasurface structures. Here we propose and investigate a new type of structure with Babinet-inverted nano-antennas which can provide a series of unit-cells with phase-shifts covering 2π and ensure almost same transmittance simultaneously. As a result, the wavefront can be manipulated by arraying the units in course. Metalenses with the linear asymmetrical double slit unit-cell arrays are designed and the simulative results exhibit their perfect focusing characteristics, including single-focus lenses and multi-focus lenses. The small focus size and high numerical aperture make them stand out from the traditional counterparts in application of precision sensing devices. We expect our designs will provide new insights in the practical applications for metasurfaces in data storages, optical information processing and optical holography.
Design and Implementation of Multifunctional Automatic Drilling End Effector
NASA Astrophysics Data System (ADS)
Wang, Zhanxi; Qin, Xiansheng; Bai, Jing; Tan, Xiaoqun; Li, Jing
2017-03-01
In order to realize the automatic drilling in aircraft assembly, a drilling end effector is designed by integrating the pressure unit, drilling unit, measurement unit, control system and frame structure. In order to reduce the hole deviation, this paper proposes a vertical normal adjustment program based on 4 laser distance sensors. The actual normal direction of workpiece surface can be calculated through the sensors measurements, and then robot posture is adjusted to realize the hole deviation correction. A base detection method is proposed to detect and locate the hole automatically by using the camera and the reference hole. The experiment results show that the position accuracy of the system is less than 0.3mm, and the normal precision is less than 0.5°. The drilling end effector and robot can greatly improve the efficiency of the aircraft parts and assembly quality, and reduce the product development cycle.
The research of laser marking control technology
NASA Astrophysics Data System (ADS)
Zhang, Qiue; Zhang, Rong
2009-08-01
In the area of Laser marking, the general control method is insert control card to computer's mother board, it can not support hot swap, it is difficult to assemble or it. Moreover, the one marking system must to equip one computer. In the system marking, the computer can not to do the other things except to transmit marking digital information. Otherwise it can affect marking precision. Based on traditional control methods existed some problems, introduced marking graphic editing and digital processing by the computer finish, high-speed digital signal processor (DSP) control marking the whole process. The laser marking controller is mainly contain DSP2812, digital memorizer, DAC (digital analog converting) transform unit circuit, USB interface control circuit, man-machine interface circuit, and other logic control circuit. Download the marking information which is processed by computer to U disk, DSP read the information by USB interface on time, then processing it, adopt the DSP inter timer control the marking time sequence, output the scanner control signal by D/A parts. Apply the technology can realize marking offline, thereby reduce the product cost, increase the product efficiency. The system have good effect in actual unit markings, the marking speed is more quickly than PCI control card to 20 percent. It has application value in practicality.
Siddiqui, Shahla; Razzak, Junaid
2010-10-06
Severe sepsis and septic shock have recently emerged as particularly acute and lethal challenges amongst critically ill patients presenting to the emergency department (ED). There are no existing data on the current practices of management of patients with severe sepsis comparing early versus late administration of appropriate broad spectrum antibiotics as part of the early goal-directed therapy that is commenced in the first few hours of presentation. To assess the difference in outcomes with early compared to late administration of antibiotics in patients with severe sepsis in the pre-intensive care unit (ICU) admission period. We defined early as within one hour of presentation to the ED. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2009); MEDLINE (1990 to February 2010); EMBASE (1990 to February 2010); and ISI web of Science (February 2010). We also searched for relevant ongoing trials in specific websites such as www.controlled-trials.com; www.clinicalstudyresults.org; and www.update-software.com. We searched the reference lists of articles. There were no constraints based on language or publication status. We planned to include randomized controlled trials of early versus late broad spectrum antibiotics in adult patients with severe sepsis in the ED, prior to admission to the intensive care unit. Two authors independently assessed articles for inclusion. We found no studies that satisfied the inclusion criteria. Based on this review we are unable to make a recommendation on the early or late use of broad spectrum antibiotics in adult patients with severe sepsis in the ED pre-ICU admission. There is a need to do large prospective double blinded randomized controlled trials on the efficacy of early (within one hour) versus late broad spectrum antibiotics in adult severe sepsis patients. Since it makes sense to start antibiotics as soon as possible in this group of seriously ill patients, administering such antibiotics earlier as opposed to later is based on anecdotal suboptimal evidence.
ACOSS-16 (Active Control of Space Structures)
1982-10-01
RADC-TR-82-225 Final Technical Report October 1982 SACOSS- 16 (ACTIVE CONTROL OF SPACE ~ STRUCTURES) Honeywell Sponsored by Defense Advanced Research ...Defense Ad. vanced Research Projects Agency or the U.S. Government. ROME AIR DEVELOPMENT CENTER Air Force Systems Command Griffiss Air Force Base, NY 13441...ELEMENT. PROJECT, TASK lo, .’ H _onevwell Systems & Research Center AREA & WORK UNIT NUMBERS 2600 Ridgway Parkway, P0 Box 312 62301E Minneapolis MN
Chemical release module facility
NASA Technical Reports Server (NTRS)
Reasoner, D. L.
1980-01-01
The chemical release module provides the capability to conduct: (1) thermite based metal vapor releases; (2) pressurized gas releases; (3) dispersed liquid releases; (4) shaped charge releases from ejected submodules; and (5) diagnostic measurements with pi supplied instruments. It also provides a basic R-F and electrical system for: (1) receiving and executing commands; (2) telemetering housekeeping data; (3) tracking; (4) monitoring housekeeping and control units; and (5) ultrasafe disarming and control monitoring.
1997-11-01
TCL Target Compound List TCLP toxicity characteristic leachate procedure TPH Total Petroleum Hydrocarbon TRV toxicity reference value TSCA...controlled environment where temperature, nutrients, and oxygen can be controlled. Gaseous emissions and leachate can also be collected and treated...wood chip mixture was then spread over a gravel base enclosed in HDPE. The treatment beds were aerated with blowers and leachate was collected in a
Protons -- The Future of Radiation Therapy?
NASA Astrophysics Data System (ADS)
Avery, Steven
2007-03-01
Cancer is the 2^nd highest cause of death in the United States. The challenges of controlling this disease remain more difficult as the population lives longer. Proton therapy offers another choice in the management of cancer care. Proton therapy has existed since the late 1950s and the first hospital based center in the United States opened in 1990. Since that time four hospital based proton centers are treating patients with other centers either under construction or under consideration. This talk will focus on an introduction to proton therapy: it's medical advantages over current treatment modalities, accelerators and beam delivery systems, applications to clinical radiation oncology and the future outlook for proton therapy.
Long-range wireless mesh network for weather monitoring in unfriendly geographic conditions.
Toledano-Ayala, Manuel; Herrera-Ruiz, Gilberto; Soto-Zarazúa, Genaro M; Rivas-Araiza, Edgar A; Bazán Trujillo, Rey D; Porrás-Trejo, Rafael E
2011-01-01
In this paper a long-range wireless mesh network system is presented. It consists of three main parts: Remote Terminal Units (RTUs), Base Terminal Units (BTUs) and a Central Server (CS). The RTUs share a wireless network transmitting in the industrial, scientific and medical applications ISM band, which reaches up to 64 Km in a single point-to-point communication. A BTU controls the traffic within the network and has as its main task interconnecting it to a Ku-band satellite link using an embedded microcontroller-based gateway. Collected data is stored in a CS and presented to the final user in a numerical and a graphical form in a web portal.
Traffic flow collection wireless sensor network node for intersection light control
NASA Astrophysics Data System (ADS)
Li, Xu; Li, Xue
2011-10-01
Wireless sensor network (WSN) is expected to be deployed in intersection to monitor the traffic flow continuously, and the monitoring datum can be used as the foundation of traffic light control. In this paper, a WSN based on ZigBee protocol for monitoring traffic flow is proposed. Structure, hardware and work flow of WSN nodes are designed. CC2431 from Texas Instrument is chosen as the main computational and transmission unit, and CC2591 as the amplification unit. The stability experiment and the actual environment experiment are carried out in the last of the paper. The results of experiments show that WSN has the ability to collect traffic flow information quickly and transmit the datum to the processing center in real time.
Design and implementation of co-operative control strategy for hybrid AC/DC microgrids
NASA Astrophysics Data System (ADS)
Mahmud, Rasel
This thesis is mainly divided in two major sections: 1) Modeling and control of AC microgrid, DC microgrid, Hybrid AC/DC microgrid using distributed co-operative control, and 2) Development of a four bus laboratory prototype of an AC microgrid system. At first, a distributed cooperative control (DCC) for a DC microgrid considering the state-of-charge (SoC) of the batteries in a typical plug-in-electric-vehicle (PEV) is developed. In DC microgrids, this methodology is developed to assist the load sharing amongst the distributed generation units (DGs), according to their ratings with improved voltage regulation. Subsequently, a DCC based control algorithm for AC microgrid is also investigated to improve the performance of AC microgrid in terms of power sharing among the DGs, voltage regulation and frequency deviation. The results validate the advantages of the proposed methodology as compared to traditional droop control of AC microgrid. The DCC-based control methodology for AC microgrid and DC microgrid are further expanded to develop a DCC-based power management algorithm for hybrid AC/DC microgrid. The developed algorithm for hybrid microgrid controls the power flow through the interfacing converter (IC) between the AC and DC microgrids. This will facilitate the power sharing between the DGs according to their power ratings. Moreover, it enables the fixed scheduled power delivery at different operating conditions, while maintaining good voltage regulation and improved frequency profile. The second section provides a detailed explanation and step-by-step design and development of an AC/DC microgrid testbed. Controllers for the three-phase inverters are designed and tested on different generation units along with their corresponding inductor-capacitor-inductor (LCL) filters to eliminate the switching frequency harmonics. Electric power distribution line models are developed to form the microgrid network topology. Voltage and current sensors are placed in the proper positions to achieve a full visibility over the microgrid. A running average filter (RAF) based enhanced phase-locked-loop (EPLL) is designed and implemented to extract frequency and phase angle information. A PLL-based synchronizing scheme is also developed to synchronize the DGs to the microgrid. The developed laboratory prototype runs on dSpace platform for real time data acquisition, communication and controller implementation.
Mental workload measurement in operator control room using NASA-TLX
NASA Astrophysics Data System (ADS)
Sugarindra, M.; Suryoputro, M. R.; Permana, A. I.
2017-12-01
The workload, encountered a combination of physical workload and mental workload, is a consequence of the activities for workers. Central control room is one department in the oil processing company, employees tasked with monitoring the processing unit for 24 hours nonstop with a combination of 3 shifts in 8 hours. NASA-TLX (NASA Task Load Index) is one of the subjective mental workload measurement using six factors, namely the Mental demand (MD), Physical demand (PD), Temporal demand (TD), Performance (OP), Effort (EF), frustration levels (FR). Measurement of a subjective mental workload most widely used because it has a high degree of validity. Based on the calculation of the mental workload, there at 5 units (DTU, NPU, HTU, DIST and OPS) at the control chamber (94; 83.33; 94.67; 81, 33 and 94.67 respectively) that categorize as very high mental workload. The high level of mental workload on the operator in the Central Control Room is a requirement to have high accuracy, alertness and can make decisions quickly