Sample records for control unit scu

  1. Small scale homelike special care units and traditional special care units: effects on cognition in dementia; a longitudinal controlled intervention study.

    PubMed

    Kok, Jeroen S; van Heuvelen, Marieke J G; Berg, Ina J; Scherder, Erik J A

    2016-02-16

    Evidence shows that living in small scale homelike Special Care Units (SCU) has positive effects on behavioural and psychological symptoms of patients with dementia. Effects on cognitive functioning in relation to care facilities, however, are scarcely investigated. The purpose of this study is to gain more insight into the effects of living in small scale homelike Special Care Units, compared to regular SCU's, on the course of cognitive functioning in dementia. A group of 67 patients with dementia who moved from a regular SCU to a small scale homelike SCU and a group of 48 patients with dementia who stayed in a regular SCU participated in the study. Cognitive and behavioural functioning was assessed by means of a neuropsychological test battery and observation scales one month before (baseline), as well as 3 (post) and 6 months (follow-up) after relocation. Comparing the post and follow-up measurement with the baseline measurement, no significant differences on separate measures of cognitive functioning between both groups were found. Additional analyses, however, on 'domain clusters' revealed that global cognitive functioning of the small scale homelike SCU group showed significantly less cognitive decline three months after the transfer (p < 0.05). Effect sizes (95% CI) show a tendency for better aspects of cognition in favour of the homelike small scaled SCU group, i.e., visual memory, picture recognition, cognitive decline as observed by representatives and the clustered domains episodic memory and global cognitive functioning. While there is no significant longitudinal effect on the progression of cognitive decline comparing small scaled homelike SCU's with regular SCU's for patients with dementia, analyses on the domain clusters and effect sizes cautiously suggest differences in favour of the small scaled homelike SCU for different aspects of cognition.

  2. New York City Police Department Street Crime Unit: An Exemplary Project.

    ERIC Educational Resources Information Center

    Halper, Andrew; Ku, Richard

    The document presents a description of the policies and procedures of the New York City Street Crime Unit (SCU) which conducts street surveillance and decoy activities. The organization and administrative structure of the SCU is studied according to the size of a unit and the chain of command requirements. The SCU's methods for selecting and…

  3. Water Quality Monitor

    NASA Technical Reports Server (NTRS)

    1982-01-01

    An automated water quality monitoring system was developed by Langley Research Center to meet a need of the Environmental Protection Agency (EPA). Designed for unattended operation in water depths up to 100 feet, the system consists of a subsurface buoy anchored in the water, a surface control unit (SCU) and a hydrophone link for acoustic communication between buoy and SCU. Primary functional unit is the subsurface buoy. It incorporates 16 cells for water sampling, plus sensors for eight water quality measurements. Buoy contains all the electronic equipment needed for collecting and storing sensor data, including a microcomputer and a memory unit. Power for the electronics is supplied by a rechargeable nickel cadmium battery that is designed to operate for about two weeks. Through hydrophone link the subsurface buoy reports its data to the SCU, which relays it to land stations. Link allows two-way communications. If system encounters a problem, it automatically shuts down and sends alert signal. Sequence of commands sent via hydrophone link causes buoy to release from anchor and float to the surface for recovery.

  4. Patient outcomes for the chronically critically ill: special care unit versus intensive care unit.

    PubMed

    Rudy, E B; Daly, B J; Douglas, S; Montenegro, H D; Song, R; Dyer, M A

    1995-01-01

    The purpose of this study was to compare the effects of a low-technology environment of care and a nurse case management case delivery system (special care unit, SCU) with the traditional high-technology environment (ICU) and primary nursing care delivery system on the patient outcomes of length of stay, mortality, readmission, complications, satisfaction, and cost. A sample of 220 chronically critically ill patients were randomly assigned to either the SCU (n = 145) or the ICU (n = 75). Few significant differences were found between the two groups in length of stay, mortality, or complications. However, the findings showed significant cost savings in the SCU group in the charges accrued during the study period and in the charges and costs to produce a survivor. The average total cost of delivering care was $5,000 less per patient in the SCU than in the traditional ICU. In addition, the cost to produce a survivor was $19,000 less in the SCU. Results from this 4-year clinical trial demonstrate that nurse case managers in a SCU setting can produce patient outcomes equal to or better than those in the traditional ICU care environment for long-term critically ill patients.

  5. Protective Effects of Scutellarin on Human Cardiac Microvascular Endothelial Cells against Hypoxia-Reoxygenation Injury and Its Possible Target-Related Proteins

    PubMed Central

    Shi, Meina; Liu, Yingting; Feng, Lixing; Cui, Yingbo; Chen, Yajuan; Wang, Peng; Wu, Wenjuan; Chen, Chen; Liu, Xuan; Yang, Weimin

    2015-01-01

    Scutellarin (SCU) is one of the main components of traditional Chinese medicine plant Erigeron breviscapus (Vant.) Hand.-Mazz. In this paper, we studied the protective effects of SCU on human cardiac microvascular endothelial cells (HCMECs) against hypoxia-reoxygenation (HR) injury and its possible target-related proteins. Results of MTT assay showed that pretreatment of SCU at doses of 1, 5, and 10 μM for 2 h could significantly inhibit the decrease in cell viability of HCMECs induced by HR injury. Subcellular fractions of cells treated with vehicle control, 1 μM SCU, HR injury, or 1 μM SCU + HR injury were separated by ultracentrifugation. The protein expression profiles of cytoplasm and membrane/nuclei fractions were checked using protein two-dimensional electrophoresis (2-DE). Proteins differentially expressed between control and SCU-treated group, control and HR group, or HR and SCU + HR group were identified using mass spectrometry (MS/MS). Possible interaction network of these target-related proteins was predicted using bioinformatic analysis. The influence of SCU on the expression levels of these proteins was confirmed using Western blotting assay. The results indicated that proteins such as p27BBP protein (EIF6), heat shock 60 kDa protein 1 (HSPD1), and chaperonin containing TCP1 subunit 6A isoform (CCT6A) might play important roles in the effects of SCU. PMID:26557144

  6. Protective Effects of Scutellarin on Human Cardiac Microvascular Endothelial Cells against Hypoxia-Reoxygenation Injury and Its Possible Target-Related Proteins.

    PubMed

    Shi, Meina; Liu, Yingting; Feng, Lixing; Cui, Yingbo; Chen, Yajuan; Wang, Peng; Wu, Wenjuan; Chen, Chen; Liu, Xuan; Yang, Weimin

    2015-01-01

    Scutellarin (SCU) is one of the main components of traditional Chinese medicine plant Erigeron breviscapus (Vant.) Hand.-Mazz. In this paper, we studied the protective effects of SCU on human cardiac microvascular endothelial cells (HCMECs) against hypoxia-reoxygenation (HR) injury and its possible target-related proteins. Results of MTT assay showed that pretreatment of SCU at doses of 1, 5, and 10 μM for 2 h could significantly inhibit the decrease in cell viability of HCMECs induced by HR injury. Subcellular fractions of cells treated with vehicle control, 1 μM SCU, HR injury, or 1 μM SCU + HR injury were separated by ultracentrifugation. The protein expression profiles of cytoplasm and membrane/nuclei fractions were checked using protein two-dimensional electrophoresis (2-DE). Proteins differentially expressed between control and SCU-treated group, control and HR group, or HR and SCU + HR group were identified using mass spectrometry (MS/MS). Possible interaction network of these target-related proteins was predicted using bioinformatic analysis. The influence of SCU on the expression levels of these proteins was confirmed using Western blotting assay. The results indicated that proteins such as p27BBP protein (EIF6), heat shock 60 kDa protein 1 (HSPD1), and chaperonin containing TCP1 subunit 6A isoform (CCT6A) might play important roles in the effects of SCU.

  7. Scutellarin-graft cationic β-cyclodextrin-polyrotaxane: Synthesis, characterization and DNA condensation.

    PubMed

    Qin, Qi; Ma, Xue; Liao, Xiali; Yang, Bo

    2017-02-01

    As a prerequisite of gene delivery in living cells, DNA condensation has attracted more and more attention. In order to improve the efficiencies of polyamine-β-cyclodextrin-based cationic polyrotaxanes (PR-EDA and PR-DETA) as DNA condensation materials, we have designed and prepared two novel scutellarin-grafted cationic polyrotaxanes (PR-EDA-SCU and PR-DETA-SCU), in which scutellarins (SCU), the planar molecules, were conjugated on the cyclodextrin molecules of PR-EDA and PR-DETA. These materials were characterized by 1D and 2D NMR, XRD, TG and DSC. The electrophoresis assays showed that pDNA condensation efficiencies of PR-EDA and PR-DETA were better than that of PR-EDA and PR-DETA. The complexes of PR-EDA, PR-DETA, PR-EDA-SCU and PR-DETA-SCU with pDNA were further investigated by zeta potential and atomic force microscopy analysis. The results indicated that the planar structure of SCU played an important role in improvement of pDNA condensation efficiencies of PR-EDA-SCU and PR-DETA-SCU. The satisfactory pDNA condensation abilities of PR-EDA-SCU and PR-DETA-SCU could be helpful in designing non-viral gene delivery vectors to control gene expression and delivery. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. First Cationic Uranyl-Organic Framework with Anion-Exchange Capabilities.

    PubMed

    Bai, Zhuanling; Wang, Yanlong; Li, Yuxiang; Liu, Wei; Chen, Lanhua; Sheng, Daopeng; Diwu, Juan; Chai, Zhifang; Albrecht-Schmitt, Thomas E; Wang, Shuao

    2016-07-05

    By controlling the extent of hydrolysis during the self-assembly process of a zwitterionic-based ligand with uranyl cations, we observed a structural evolution from the neutral uranyl-organic framework [(UO2)2(TTTPC)(OH)O(COOH)]·1.5DMF·7H2O (SCU-6) to the first cationic uranyl-organic framework with the formula of [(UO2)(HTTTPC)(OH)]Br·1.5DMF·4H2O (SCU-7). The crystal structures of SCU-6 and SCU-7 are layers built with tetranuclear and dinuclear uranyl clusters, respectively. Exchangeable halide anions are present in the interlaminar spaces balancing the positive charge of layers in SCU-7. Therefore, SCU-7 is able to effectively remove perrhenate anions from aqueous solution. Meanwhile, the H2PO4(-)-exchanged SCU-7 material exhibits a moderate proton conductivity of 8.70 × 10(-5) S cm(-1) at 50 °C and 90% relative humidity, representing nearly 80 times enhancement compared to the original material.

  9. Scutellarin protects against Aβ-induced learning and memory deficits in rats: involvement of nicotinic acetylcholine receptors and cholinesterase

    PubMed Central

    Guo, Li-li; Guan, Zhi-zhong; Wang, Yong-lin

    2011-01-01

    Aim: To examine the protective effects of scutellarin (Scu) on rats with learning and memory deficit induced by β-amyloid peptide (Aβ). Methods: Fifty male Wistar rats were randomly divided into 5 groups: control, sham operation, Aβ, Aβ+Scu, and Aβ+piracetam groups. Aβ25–35 was injected into the lateral ventricle (10 μg each side). Scu (10 mg/2 mL) or piracetam (10 mg/2 mL was intragastrically administered per day for 20 consecutive days following Aβ treatment. Learning and memory was assessed with Morris water maze test. The protein and mRNA levels of nicotinic acetylcholine receptor (nAChR) α4, α7, and β2 subunits in the brain were examined using Western blotting and real-time PCR, respectively. The activities of acetylcholinesterase (AChE) and butyrylcholinesterase (BuChE) in the brain and plasma were measured using Ellman's colorimetric method. Results: In Aβ group, the escape latency period and first platform cross was significantly increased, and the total number of platform crossings was significantly decreased, as compared with the control and the sham operation groups. Both Scu and piracetam treatment significantly reduced the escape latency period and time to cross platform, and increased the number of platform crosses, but there were no significant differences between Aβ+Scu and Aβ+piracetam groups. In Aβ group, the protein levels of nAChR α4 and α7 subunits in the cerebral cortex were significantly decreased by 42%–47% and 58%–61%, respectively, as compared to the control and the sham operation groups. Scu treatment caused upregulation of α4 and α7 subunit proteins by around 24% and 30%, respectively, as compared to Aβ group, but there were no significant differences between Aβ+Scu and Aβ+piracetam groups. The protein level of nAChR β2 subunit had no significant difference among different groups. The mRNA levels of nAChR α4, α7, and β2 subunits were not significantly changed. In Aβ group, the activities of AChE and BuChE in the brain were significantly increased, but were significantly decreased in the plasma, as compared to the control and the sham operation groups. Scu or piracetam treatment restored the activities in brain and plasma nearly to the levels in the control group. Conclusion: The results suggest that Scu may rescue some of the deleterious effects of Aβ, possibly by stimulating nAChR protein translation and regulating cholinesterase activity. PMID:21986571

  10. Effect of coated urea on cadmium accumulation in Oryza sativa L. grown in contaminated soil.

    PubMed

    Xu, Chao; Wu, Zisong; Zhu, Qihong; Zhu, Hanhua; Zhang, Yangzhu; Huang, Daoyou

    2015-11-01

    Experiments were conducted to determine the effects of three types of coated urea on the accumulation of cadmium (Cd) in rice (Oryza sativa L.) grown in contaminated soil. Pot-culture experiments were conducted in a greenhouse from July to November 2012 on the rice cultivar "Hua Hang Si Miao" in Guangzhou (China). The experimental design was completely randomized with four treatments and three replications. The treatments were control (CK) (N 0 mg/kg), prilled urea (PU) (N 200 mg/kg), polymer-coated urea (PCU) (N 200 mg/kg), and sulfur-coated urea (SCU) (N 200 mg/kg). Our results indicated that applications of PCU and SCU slightly increased the dry weight of rice grains. The application of SCU significantly decreased the CaCl2 and toxicity characteristic leaching procedure (TCLP)-extractable Cd concentrations by 15.4 and 56.1%, respectively. Sequential extractions showed that PCU and SCU applications led to a significant decrease in Cd in the exchangeable fraction and an increase in the bound iron (Fe) and manganese (Mn) oxides fractions. Cd concentrations in grains treated with PCU were reduced by 11.7%, whereas SCU significantly reduced Cd concentrations by 29.1%. SCU reduced Cd transfer from the straws to the grain. Our results demonstrated that PCU and SCU may be effective in mitigating Cd accumulation in rice grown in acidic Cd-contaminated soil, especially in plants receiving SCU.

  11. Bolus dose response characteristics of single chain urokinase plasminogen activator and tissue plasminogen activator in a dog model of arterial thrombosis.

    PubMed

    Badylak, S F; Voytik, S; Klabunde, R E; Henkin, J; Leski, M

    1988-11-15

    Tissue plasminogen activator (t-PA) and single chain urokinase-plasminogen activator (scu-PA) are relatively "fibrin-specific" thrombolytic drugs with short plasma half lives of 6-8 minutes. Most treatment regimens with these agents utilize a bolus injection followed by continuous drug infusion, usually combined with anticoagulant therapy. The purpose of this study was to establish the dose-response characteristics for scu-PA and t-PA, when given as a single intravenous bolus injection, in a dog model of arterial thrombosis. Eight groups of 6 dogs each were given one of the following doses of scu-PA (mg/kg): 0.20, 0.50, 1.00, 2.00; or t-PA: 0.05, 0.10, 0.20; or an equivalent amount of saline (control group). All doses were given as a single bolus injection 60 minutes after formation of a totally occlusive femoral artery thrombus. Thrombolysis was measured by monitoring the continuous decrement of 125I activity from a radiolabelled thrombus. Ninety minutes after drug injection, all scu-PA treated dogs showed greater thrombolysis (30%, 45%, 56%, and 67%, respectively) than the control group (15%, p less than 0.01). The 0.10 and 0.20 mg/kg t-PA treated dogs showed greater thrombolysis (35% and 49%, respectively) than the control group (15%, p less than 0.01). Both scu-PA and t-PA caused a partial and dose-dependent decrease in alpha 2-antiplasmin activity but scu-PA caused a greater depletion (72% vs. 18%, respectively, p less than 0.05) at 60 minutes after the highest dose of drug administration. Both drugs showed a longer than expected thrombolytic effect based upon the known half lives. Neither drug caused significant changes in the prothrombin time, activated partial thromboplastin time, thrombin time, hematocrit, platelet count, or fibrin degradation product concentration. Single bolus injections of scu-PA and t-PA produce safe and effective thrombolysis in this dog model of arterial thrombosis.

  12. Dimensions of care for dementia sufferers in long-term care institutions: are they related to outcomes?

    PubMed

    Chappell, N L; Reid, R C

    2000-07-01

    This study empirically examined whether dimensions of care cluster in special care units (SCUs) compared with non-SCUs. The relationship between SCU status plus separate measures of the dimensions of care and outcomes for dementia sufferers was then investigated. Data were drawn from the Intermediate Care Facility Project. The sample (N = 510) included residents with dementia, aged 65 and older, in intermediate care facilities throughout the province of British Columbia. Canada. Longitudinal data included 6 outcomes: cognitive function, behavioral problems of agitation and social skills, physical functioning, and quality of life measured through affect and expressive language skills. Separate multiple linear regression equations were estimated, relating each of these outcomes to 5 dimensions of care: preadmission and admission procedures. staff training and education, nonuse of physical and chemical restraints, flexible care routines and resident-relevant activities, and the environment. The results showed there is virtually no clustering of dimensions along SCU/non-SCU lines. Neither SCU status nor the individual dimensions were highly predictive of outcomes. Residents' affect at t1 emerged as a characteristic that was significantly correlated with other outcomes. This Canadian research can be added to the few but growing number of rigorous studies that suggest SCUs are not homogeneous and do not necessarily provide better care than non-SCUs. Moreover, it raises questions about the benefits of "best practice" dimensions of care, regardless of SCU status.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanyushenkov, Y.; Doose, C.; Fuerst, J.

    Development of superconducting undulator (SCU) technology continues at the Advanced Photon Source (APS). The experience of building and successful operating the first short-length, 16-mm period length superconducting undulator SCU0 paved the way for a 1-m long, 18-mm period device— SCU18-1— which has been in operation since May 2015. The APS SCU team has also built and tested a 1.5-m long, 21-mm period length undulator as a part of the LCLS SCU R&D program, aimed at demonstration of SCU technology availability for free electron lasers. This undulator successfully achieved all the requirements including a phase error of 5° RMS. Our teammore » has recently completed one more 1-m long, 18-mm period length undulator— SCU18-2— that is replacing the SCU0. We are also working on a helical SCU for the APS. The status of these projects will be presented.« less

  14. The BepiColombo/SERENA package: Serena Integrated Test campaign

    NASA Astrophysics Data System (ADS)

    Orsini, S.; De Angelis, E.; Livi, S.; Lichtenegger, H.; Barabash, S.; Milillo, A.; Wurz, P.; Olivieir, A.; D'Arcio, L.; Philips, M.; Laky, G.; Wieser, M.; Camozzi, F.; Di Lellis, A. M.; Rispoli, R.; Jeszenesky, H.; Mura, A.; Aronica, A.; Lazzarotto, F.; Vertolli, N.

    2017-09-01

    The activities related to the BepiColombo/ MPO/SERENA Integrated Test (SIT, held in February-March 2017 inside the thermal vacuum facility at the University of Bern, Phys. Inst.) are presented. This campaign has been a unique opportunity to test the experiment performances, with all the four flight-spare instruments of SERENA (ELENA, STROFIO, PICAM, and MIPA, simultaneously operated by the System Control Unit (SCU), in a fully operational configuration.

  15. Health outcomes and quality of life of residents of shared-housing arrangements compared to residents of special care units - results of the Berlin DeWeGE-study.

    PubMed

    Wolf-Ostermann, Karin; Worch, Andreas; Fischer, Thomas; Wulff, Ines; Gräske, Johannes

    2012-11-01

    To compare different health outcomes as well as quality of life (QoL) between people with dementia living in shared-housing arrangements (SHA) and special care units (SCU) in nursing homes. Often situated in large apartments in mostly urban settings, SHA are a specific German kind of small-scale living facilities for older care-dependent persons, predominantly suffering from dementia. SHA are completely disconnected from traditional nursing homes. In a longitudinal design, all new residents of SHA and SCU suffering with dementia in Berlin were surveyed for one year. They were assessed when they moved into the SHA or SCU and again 6 and 12 months later. We surveyed physical and psychological health outcomes including ADL-functioning (Barthel), neuropsychiatric symptoms of dementia (NPI) and challenging behaviour (Cohen-Mansfield agitation inventory) as well as QoL (Qualidem). Fifty-six persons (43 women, 13 men) were recruited into the longitudinal study. The average age was 82·5 years at admission, participants mostly had a moderate level of cognitive impairment (mean Mini Mental State Examination = 13·3), prevalence of neuropsychiatric symptoms was high. During the one-year follow-up, analyses show a significant decrease in cognitive abilities but also of neuropsychiatric symptoms in both groups. In SHA, QoL increases on average during the one-year study period. Both types of facilities attract slightly different populations according to our data. Comparison of SHA residents to SCU residents documented no significant beneficial effects of settings in terms of health outcomes. As no clear advantage of either SHA or SCU in nursing homes can be demonstrated for residents with dementia who move in newly, it is impossible to give a clear evidence-based recommendation and the decision for one setting or the other can be made according solely to personal preference of the resident. © 2012 Blackwell Publishing Ltd.

  16. In-Flight Validation of a Pilot Rating Scale for Evaluating Failure Transients in Electronic Flight Control Systems

    NASA Technical Reports Server (NTRS)

    Kalinowski, Kevin F.; Tucker, George E.; Moralez, Ernesto, III

    2006-01-01

    Engineering development and qualification of a Research Flight Control System (RFCS) for the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-60A has motivated the development of a pilot rating scale for evaluating failure transients in fly-by-wire flight control systems. The RASCAL RFCS includes a highly-reliable, dual-channel Servo Control Unit (SCU) to command and monitor the performance of the fly-by-wire actuators and protect against the effects of erroneous commands from the flexible, but single-thread Flight Control Computer. During the design phase of the RFCS, two piloted simulations were conducted on the Ames Research Center Vertical Motion Simulator (VMS) to help define the required performance characteristics of the safety monitoring algorithms in the SCU. Simulated failures, including hard-over and slow-over commands, were injected into the command path, and the aircraft response and safety monitor performance were evaluated. A subjective Failure/Recovery Rating (F/RR) scale was developed as a means of quantifying the effects of the injected failures on the aircraft state and the degree of pilot effort required to safely recover the aircraft. A brief evaluation of the rating scale was also conducted on the Army/NASA CH-47B variable stability helicopter to confirm that the rating scale was likely to be equally applicable to in-flight evaluations. Following the initial research flight qualification of the RFCS in 2002, a flight test effort was begun to validate the performance of the safety monitors and to validate their design for the safe conduct of research flight testing. Simulated failures were injected into the SCU, and the F/RR scale was applied to assess the results. The results validate the performance of the monitors, and indicate that the Failure/Recovery Rating scale is a very useful tool for evaluating failure transients in fly-by-wire flight control systems.

  17. Active α-macroglobulin is a reservoir for urokinase after fibrinolytic therapy in rabbits with tetracycline-induced pleural injury and in human pleural fluids

    PubMed Central

    Florova, Galina; Azghani, Ali; Karandashova, Sophia; Kurdowska, Anna K.; Idell, Steven

    2013-01-01

    Intrapleural processing of prourokinase (scuPA) in tetracycline (TCN)-induced pleural injury in rabbits was evaluated to better understand the mechanisms governing successful scuPA-based intrapleural fibrinolytic therapy (IPFT), capable of clearing pleural adhesions in this model. Pleural fluid (PF) was withdrawn 0–80 min and 24 h after IPFT with scuPA (0–0.5 mg/kg), and activities of free urokinase (uPA), plasminogen activator inhibitor-1 (PAI-1), and uPA complexed with α-macroglobulin (αM) were assessed. Similar analyses were performed using PFs from patients with empyema, parapneumonic, and malignant pleural effusions. The peak of uPA activity (5–40 min) reciprocally correlated with the dose of intrapleural scuPA. Endogenous active PAI-1 (10–20 nM) decreased the rate of intrapleural scuPA activation. The slow step of intrapleural inactivation of free uPA (t1/2β = 40 ± 10 min) was dose independent and 6.7-fold slower than in blood. Up to 260 ± 70 nM of αM/uPA formed in vivo [second order association rate (kass) = 580 ± 60 M−1·s−1]. αM/uPA and products of its degradation contributed to durable intrapleural plasminogen activation up to 24 h after IPFT. Active PAI-1, active α2M, and α2M/uPA found in empyema, pneumonia, and malignant PFs demonstrate the capacity to support similar mechanisms in humans. Intrapleural scuPA processing differs from that in the bloodstream and includes 1) dose-dependent control of scuPA activation by endogenous active PAI-1; 2) two-step inactivation of free uPA with simultaneous formation of αM/uPA; and 3) slow intrapleural degradation of αM/uPA releasing active free uPA. This mechanism offers potential clinically relevant advantages that may enhance the bioavailability of intrapleural scuPA and may mitigate the risk of bleeding complications. PMID:23997178

  18. Calibration of Fast Fiber-Optic Beam Loss Monitors for the Advanced Photon Source Storage Ring Superconducting Undulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooling, J.; Harkay, K.; Ivanyushenkov, Y.

    2015-01-01

    We report on the calibration and use of fast fiber-optic (FO) beam loss monitors (BLMs) in the Advanced Photon Source storage ring (SR). A superconducting undulator prototype (SCU0) has been operating in SR Sector 6 (“ID6”) since the beginning of CY2013, and another undulator SCU1 (a 1.1-m length undulator that is three times the length of SCU0) is scheduled for installation in Sector 1 (“ID1”) in 2015. The SCU0 main coil often quenches during beam dumps. MARS simulations have shown that relatively small beam loss (<1 nC) can lead to temperature excursions sufficient to cause quenchingwhen the SCU0windings are nearmore » critical current. To characterize local beam losses, high-purity fused-silica FO cables were installed in ID6 on the SCU0 chamber transitions and in ID1 where SCU1 will be installed. These BLMs aid in the search for operating modes that protect the SCU structures from beam-loss-induced quenching. In this paper, we describe the BLM calibration process that included deliberate beam dumps at locations of BLMs. We also compare beam dump events where SCU0 did and did not quench.« less

  19. Is our medical school socially accountable? The case of Faculty of Medicine, Suez Canal University.

    PubMed

    Hosny, Somaya; Ghaly, Mona; Boelen, Charles

    2015-04-01

    Faculty of Medicine, Suez Canal University (FOM/SCU) was established as community oriented school with innovative educational strategies. Social accountability represents the commitment of the medical school towards the community it serves. To assess FOM/SCU compliance to social accountability using the "Conceptualization, Production, Usability" (CPU) model. FOM/SCU's practice was reviewed against CPU model parameters. CPU consists of three domains, 11 sections and 31 parameters. Data were collected through unstructured interviews with the main stakeholders and documents review since 2005 to 2013. FOM/SCU shows general compliance to the three domains of the CPU. Very good compliance was shown to the "P" domain of the model through FOM/SCU's innovative educational system, students and faculty members. More work is needed on the "C" and "U" domains. FOM/SCU complies with many parameters of the CPU model; however, more work should be accomplished to comply with some items in the C and U domains so that FOM/SCU can be recognized as a proactive socially accountable school.

  20. A Survey of the Pain Management of Acute Painful Crisis among Patients with Sickle Cell Disease at Two Centres in Jamaica.

    PubMed

    Augier, R; Jenkins, S; Bortolusso Ali, S; Tennant, I; Williams-Johnson, J; Reid, M

    2014-06-01

    The aim of this survey was to establish the pain management approaches to acute painful crisis (APC) in sickle cell patients at two healthcare facilities and to compare with available guidelines. A multi-centre observational survey of the management of APC in sickle cell patients was conducted. Data were collected at the Sickle Cell Unit (SCU), Tropical Medicine Research Institute (TMRI) and Accident and Emergency Department (A&E), University Hospital of the West Indies. One hundred episodes of uncomplicated APC involving 81 patients managed at the SCU clinic and 64 episodes at the A&E in a total of 28 patients were included in the data set. Drugs used at the SCU included oral morphine, codeine and paracetamol and intramuscular diclofenac. At the A&E, parenteral morphine and pethidine were most commonly used. At the SCU, the mean time to initiation of analgesics was 38 minutes (IQR 25 to 50 minutes); at the A&E, this was 111 minutes (IQR 50 to 150 minutes). At the SCU, the mean duration of stay (DOS) was 2.9 hours (IQR 1.9 to 3.8 hours) with 94% of the patients being discharged home. At the A&E, the mean DOS was 13.0 hours (IQR 8.3 to 16.9 hours) with 93% of the patients being discharged home. The A&E patient group contained multiple high frequency presenters. Documentation of pain severity scores was inconsistent. The findings of the survey indicate that the management of APC at the two centres is substantially different. Further study is required to investigate patient satisfaction, centre preference and analgesic therapy efficacy.

  1. SHARP Demonstration Flight: Video Broadcast System for Research in Intelligent Flight Characterization and Control

    NASA Technical Reports Server (NTRS)

    Kitts, Christopher

    2001-01-01

    The NASA Ames Research Center (Thermal Protection Materials and Systems Branch) is investigating new ceramic materials for the thermal protection of atmospheric entry vehicles. An incremental approach to proving the capabilities of these materials calls for a lifting entry flight test of a sharp leading edge component on the proposed SHARP (Slender Hypervelocity Aerothermodynamic Research Probe) vehicle. This flight test will establish the aerothermal performance constraint under real lifting entry conditions. NASA Ames has been developing the SHARP test flight with SSDL (responsible for the SHARP S I vehicle avionics), Montana State University (responsible for the SHARP S I vehicle airframe), the Wickman Spacecraft and Propulsion Company (responsible for the sounding rocket and launch operations), and with the SCU Intelligent Robotics Program, The SCU team was added well after the rest of the development team had formed. The SCU role was to assist with the development of a real-time video broadcast system which would relay onboard flight video to a communication groundstation. The SCU team would also assist with general vehicle preparation as well as flight operations. At the time of the submission of the original SCU proposal, a test flight in Wyoming was originally targeted for September 2000. This date was moved several times into the Fall of 2000. It was then postponed until the Spring of 2001, and later pushed into late Summer 2001. To date, the flight has still not taken place. These project delays resulted in SCU requesting several no-cost extensions to the project. Based on the most recent conversations with the project technical lead, Paul Kolodjiez, the current plan is for the overall SHARP team to assemble what exists of the vehicle, to document the system, and to 'mothball' the vehicle in anticipation of future flight and funding opportunities.

  2. Improvement of the control of a gas metal arc welding process

    NASA Astrophysics Data System (ADS)

    Gött, Gregor; Schöpp, Heinz; Hofmann, Frank; Heinz, Gerd

    2010-02-01

    Up to now, the use of the electrical characteristics for process control is state of the art in gas metal arc welding (GMAW). The aim of the work is the improvement of GMAW processes by using additional information from the arc. Therefore, the emitted light of the arc is analysed spectroscopically and compared with high-speed camera images. With this information, a conclusion about the plasma arc and the droplet formation is reasonable. With the correlation of the spectral and local information of the plasma, a specific control of the power supply can be applied. A corresponding spectral control unit (SCU) is introduced.

  3. Intelligent surgical laser system configuration and software implementation

    NASA Astrophysics Data System (ADS)

    Hsueh, Chi-Fu T.; Bille, Josef F.

    1992-06-01

    An intelligent surgical laser system, which can help the ophthalmologist to achieve higher precision and control during their procedures, has been developed by ISL as model CLS 4001. In addition to the laser and laser delivery system, the system is also equipped with a vision system (IPU), robotics motion control (MCU), and a tracking closed loop system (ETS) that tracks the eye in three dimensions (X, Y and Z). The initial patient setup is computer controlled with guidance from the vision system. The tracking system is automatically engaged when the target is in position. A multi-level tracking system is developed by integrating our vision and tracking systems which have been able to maintain our laser beam precisely on target. The capabilities of the automatic eye setup and the tracking in three dimensions provides for improved accuracy and measurement repeatability. The system is operated through the Surgical Control Unit (SCU). The SCU communicates with the IPU and the MCU through both ethernet and RS232. Various scanning pattern (i.e., line, curve, circle, spiral, etc.) can be selected with given parameters. When a warning is activated, a voice message is played that will normally require a panel touch acknowledgement. The reliability of the system is ensured in three levels: (1) hardware, (2) software real time monitoring, and (3) user. The system is currently under clinical validation.

  4. Associations of Special Care Units and Outcomes of Residents with Dementia: 2004 National Nursing Home Survey

    ERIC Educational Resources Information Center

    Luo, Huabin; Fang, Xiangming; Liao, Youlian; Elliott, Amanda; Zhang, Xinzhi

    2010-01-01

    Purpose: We compared the rates of specialized care for residents with Alzheimer's disease or dementia in special care units (SCUs) and other nursing home (NH) units and examined the associations of SCU residence with process of care and resident outcomes. Design and Methods: Data came from the 2004 National Nursing Home Survey. The indicators of…

  5. Scutellarin’s Cardiovascular Endothelium Protective Mechanism: Important Role of PKG-Iα

    PubMed Central

    Chen, Chen; Yang, Jian; Li, Jiaxun; Hu, Na; Li, Yang; Zhang, Dongmei; Guo, Tao; Liu, Xuan; Yang, Weimin

    2015-01-01

    Scutellarin (SCU), a flavonoid glycoside compound, has been successfully used in clinic for treatment of ischemic diseases in China. In this report, we checked the effects of SCU on endothelium dysfunction (ED) of coronary artery (CA) against myocardial ischemia reperfusion (MIR) injury in vivo. The involvement of PKG-Iα was further studied using cultured endothelial cells subjected to hypoxia reoxygenation (HR) injury in vitro. In rat MIR model, SCU (45 and 90 mg/kg, iv) significantly reduced ischemic size and restored the endothelium-dependent vasodilation of isolated CA rings. PKG inhibitor Rp-8-Br-cGMP (50 μg/kg, iv) could ameliorate the protective effects of SCU. Increase in phosphorylation of vasodilator-stimulated phosphoprotein (VASP), a main substrate of PKG, at Ser 239 was observed in both heart tissue and serum of SCU-treated animals. In cultured human cardiac microvascular endothelial cells (HCMECs), SCU (1 and 10 μM) dose-dependently protected cell viability and increased the mRNA and protein level of PKG-Iα against HR injury. The activity of PKG was also increased by SCU treatment. The activation of PKG–1α was then studied using targeted proteomic analysis (MRM-MS) checking the phosphorylation state of the autophosphorylation domain (aa42-94). Significant decrease in phosphorylation of PKG-Iα at Ser50, Ser72, Ser89 was induced by HR injury while SCU treatment significantly increased the phosphorylation of PKG-Iα, not only at Ser50, Ser72 and Ser89, but also at Ser44 and Thr58 (two novel phosphorylation domains). Our results demonstrate PKG-Iα might play an important role in the protective effects of SCU on ED against MIR injury. PMID:26440524

  6. Regulation of intrapleural fibrinolysis by urokinase-α-macroglobulin complexes in tetracycline-induced pleural injury in rabbits

    PubMed Central

    Mazar, Andrew P.; Koenig, Kathy; Kurdowska, Anna K.; Idell, Steven

    2009-01-01

    The proenzyme single-chain urokinase plasminogen activator (scuPA) more effectively resolved intrapleural loculations in rabbits with tetracycline (TCN)-induced loculation than a range of clinical doses of two-chain uPA (Abbokinase) and demonstrated a trend toward greater efficacy than single-chain tPA (Activase) (Idell S et al., Exp Lung Res 33: 419, 2007.). scuPA more slowly generates durable intrapleural fibrinolytic activity than Abbokinase or Activase, but the interactions of these agents with inhibitors in pleural fluids (PFs) have been poorly understood. PFs from rabbits with TCN-induced pleural injury treated with intrapleural scuPA, its inactive Ser195Ala mutant, Abbokinase, Activase, or vehicle, were analyzed to define the mechanism by which scuPA induces durable fibrinolysis. uPA activity was elevated in PFs of animals treated with scuPA, correlated with the ability to clear pleural loculations, and resisted (70–80%) inhibition by PAI-1. α-macroglobulin (αM) but not urokinase receptor complexes immunoprecipitated from PFs of scuPA-treated rabbits retained uPA activity that resists PAI-1 and activates plasminogen. Conversely, little plasminogen activating or enzymatic activity resistant to PAI-1 was detectable in PFs of rabbits treated with Abbokinase or Activase. Consistent with these findings, PAI-1 interacts with scuPA much slower than with Activase or Abbokinase in vitro. An equilibrium between active and inactive scuPA (kon = 4.3 h−1) limits the rate of its inactivation by PAI-1, favoring formation of complexes with αM. These observations define a newly recognized mechanism that promotes durable intrapleural fibrinolysis via formation of αM/uPA complexes. These complexes promote uPA-mediated plasminogen activation in scuPA-treated rabbits with TCN-induced pleural injury. PMID:19666776

  7. Development of Southern Cross University College

    ERIC Educational Resources Information Center

    MacGillivray, W. R.

    2013-01-01

    Southern Cross University (SCU) has established a pathways college to increase access to and widen participation in higher education for people in regional areas of Australia. While many Australian universities have preparatory colleges associated with them, SCU College has been designed to make it unique in the sector. SCU College will operate…

  8. Serial network simplifies the design of multiple microcomputer systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Folkes, D.

    1981-01-01

    Recently there has been a lot of interest in developing network communication schemes for carrying digital data between locally distributed computing stations. Many of these schemes have focused on distributed networking techniques for data processing applications. These applications suggest the use of a serial, multipoint bus, where a number of remote intelligent units act as slaves to a central or host computer. Each slave would be serially addressable from the host and would perform required operations upon being addressed by the host. Based on an MK3873 single-chip microcomputer, the SCU 20 is designed to be such a remote slave device.more » The capabilities of the SCU 20 and its use in systems applications are examined.« less

  9. Novel cationic lipid nanoparticles as an ophthalmic delivery system for multicomponent drugs: development, characterization, in vitro permeation, in vivo pharmacokinetic, and molecular dynamics studies.

    PubMed

    Wang, Jialu; Zhao, Fang; Liu, Rui; Chen, Jingjing; Zhang, Qinghua; Lao, Ruijuan; Wang, Ze; Jin, Xin; Liu, Changxiao

    2017-01-01

    The purpose of this study was to prepare, optimize, and characterize a cationic lipid nanoparticle (CLN) system containing multicomponent drugs using a molecular dynamics model as a novel method of evaluating formulations. Puerarin (PUE) and scutellarin (SCU) were used as model drugs. CLNs were successfully prepared using melt-emulsion ultrasonication and low temperature-solidification technique. The properties of CLNs such as morphology, particle size, zeta potential, entrapment efficiency (EE), drug loading (DL), and drug release behavior were investigated. The CLNs were evaluated by corneal permeation, preocular retention time, and pharmacokinetics in the aqueous humor. Additionally, a molecular dynamics model was used to evaluate the formulation. Electron microscopy results showed that the nanoparticles were approximately spherical in shape. The EE (%) and DL (%) values of PUE and SCU in the optimal formulation were 56.60±3.73, 72.31±1.96 and 1.68±0.17, 2.44±1.14, respectively. The pharmacokinetic study in the aqueous humor showed that compared with the PUE and SCU solution, the area under the concentration-time curve (AUC) value of PUE was enhanced by 2.33-fold for PUE-SCU CLNs ( p <0.01), and the SCU AUC was enhanced by 2.32-fold ( p <0.01). In the molecular dynamics model, PUE and SCU passed through the POPC bilayer, with an obvious difference in the free energy well depth. It was found that the maximum free energy required for PUE and SCU transmembrane movement was ~15 and 88 kJ·mol -1 , respectively. These findings indicated that compared with SCU, PUE easily passed through the membrane. The diffusion coefficient for PUE and SCU were 4.1×10 -3 ±0.0027 and 1.0×10 -3 ±0.0006 e -5 cm 2 ·s -1 , respectively. Data from the molecular dynamics model were consistent with the experimental data. All data indicated that CLNs have a great potential for ocular administration and can be used as an ocular delivery system for multicomponent drugs. Moreover, the molecular dynamics model can also be used as a novel method for evaluating formulations.

  10. Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Ivanyushenkov, Y.; Harkay, K.; Borland, M.; Dejus, R.; Dooling, J.; Doose, C.; Emery, L.; Fuerst, J.; Gagliano, J.; Hasse, Q.; Kasa, M.; Kenesei, P.; Sajaev, V.; Schroeder, K.; Sereno, N.; Shastri, S.; Shiroyanagi, Y.; Skiadopoulos, D.; Smith, M.; Sun, X.; Trakhtenberg, E.; Xiao, A.; Zholents, A.; Gluskin, E.

    2017-10-01

    Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator "SCU0" in Sector 6 of the APS storage ring, the second 1.1-m-long superconducting undulator "SCU1" was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1's magnetic and cryogenic performance as well as its operating experience in the APS storage ring are also presented.

  11. Protective effect of scutellarin on myocardial infarction induced by isoprenaline in rats

    PubMed Central

    Huang, Haibo; Geng, Qianqian; Yao, Hong; Shen, Zhenhuang; Wu, Zhenhong; Miao, Xiaoqing; Shi, Peiying

    2018-01-01

    Objective(s): Scutellarin (Scu) is the main effective constituent of Erigeron breviscapus which has anti-oxidant, anti-apoptotic, anti-inflammatory and other therapeutic properties. The purpose of this study was to investigate the protective effect of Scu on myocardial infarction (MI) induced by isoprenaline (ISO). Materials and Methods: The rats were subcutaneously injected with ISO (45 mg/kg) on the first day, then single tail-intravenously injected with different doses of Scu (10 mg/kg, 20 mg/kg, 40 mg/kg) for 7 consecutive days. The protective effect of Scu on ISO-induced MI was evaluated by measuring markers of heart injury in serum, levels of lipid peroxidation, and antioxidants in heart tissue, observing pathological changes of tissue, and detecting quantified expression of apoptotic-related family members and inflammation. Results: Compared with the model group, the concentration of troponin T (CTn-T) and troponin I (CTn-I), aspartate aminotransferase (AST), and lactate dehydrogenase (LDH) in the serum all decreased in the Scu high dose group. The activities of superoxide dismutase (SOD), catalase (CAT), and the content of reduced glutathione (GSH) in heart increased, and the content of malondialdehyde (MDA) and inducible nitric oxide synthase (iNOS) decreased. In addition, the histopathologic aspects showed that pathological heart change was found in the model group, and was reduced to varying degrees in the Scu group. Moreover, the expression of Bax, P53, Caspase3, Caspase9, cytochrome C, NGAL, NFκB, IL-1β and IL-6 in the heart decreased, while the expression of Bcl2 increased. Conclusion: Scu could reduce the degree of MI induced by ISO by improving the antioxidant, anti-apoptotic, and anti-inflammatory capacities of the body. PMID:29511493

  12. Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon Source

    DOE PAGES

    Ivanyushenkov, Y.; Harkay, K.; Borland, M.; ...

    2017-10-03

    Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator “SCU0” in Sector 6 of the APS storage ring, the second 1.1-m long superconducting undulator “SCU1” was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1’s magnetic and cryogenic performance as well as its operating experience in the APS storage ring are alsomore » presented.« less

  13. Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanyushenkov, Y.; Harkay, K.; Borland, M.

    Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator “SCU0” in Sector 6 of the APS storage ring, the second 1.1-m long superconducting undulator “SCU1” was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1’s magnetic and cryogenic performance as well as its operating experience in the APS storage ring are alsomore » presented.« less

  14. Does Cognitive Impairment Influence Quality of Life among Nursing Home Residents?

    ERIC Educational Resources Information Center

    Abrahamson, Kathleen; Clark, Daniel; Perkins, Anthony; Arling, Greg

    2012-01-01

    Purpose: We investigated the relationship between cognitive status and quality of life (QOL) of Minnesota nursing home (NH) residents and the relationship between conventional or Alzheimer's special care unit (SCU) placement and QOL. The study may inform development of dementia-specific quality measures. Design and Methods: Data for analyses came…

  15. Towards personalized care for persons with spinal cord injury: a study on patients' perceptions

    PubMed Central

    Garrino, Lorenza; Curto, Natascia; Decorte, Rita; Felisi, Nadia; Matta, Ebe; Gregorino, Silvano; Actis, M. Vittoria; Marchisio, Cecilia; Carone, Roberto

    2011-01-01

    Objective/background A newly designed Spinal Cord Unit (SCU) was set up at the Orthopedic Traumatology Center (OTC), Turin, Italy, in July 2007. With the relocation of the SCU came the need to reorganize and improve the delivery of its services. The study reported here is a preliminary part of a project entitled ‘Experimentation and evaluation of personalized healthcare for patients with spinal cord injury’, which is a component of an overarching program of targeted research into healthcare funded by the Piedmont Region in 2006. The aim of this study was to assess the perception of care by patients with spinal cord injury (SCI) by collecting important data in order to determine whether an integrated and personalized care pathway could be effective both in hospital and in a rehabilitation setting. Design Qualitative research study. The interview format was based on a narrative approach. Methods Qualitative in-depth semi-structured interviews were conducted with 21 patients with SCI. Qualitative content analysis was used to identify categories and themes arising from the data. Results Six main categories emerged from the perspectives of patients: expectations of rehabilitation care, impact and welcome, relationship with nurses and their involvement in treatment, relationship with physical therapists and participation in rehabilitation programs, relationship with physicians and their availability and attendance, and imparting of information on injury and rehabilitation outcomes. Care was the aspect new patients admitted to the SCU found most important. When closer relationships with staff formed, the healthcare professionals became an essential support. Patients with SCI commonly stated that receiving explicit information was necessary for accepting their condition. Conclusions Analysis of the patients' perceptions revealed a wealth of details on their experience in the SCU and the need for flexible planning of care time in particular. Incorporating the patients' perceptions into a new care model could increase professionals' awareness of patients' needs and provide a useful basis for constructing a personalized care plan. PMID:21528629

  16. Enhancement of scutellarin oral delivery efficacy by vitamin B12-modified amphiphilic chitosan derivatives to treat type II diabetes induced-retinopathy.

    PubMed

    Wang, Jingnan; Tan, Jiayun; Luo, Jiahao; Huang, Peilin; Zhou, Wuyi; Chen, Luming; Long, Lingli; Zhang, Li-Ming; Zhu, Banghao; Yang, Liqun; Deng, David Y B

    2017-03-01

    Diabetic retinopathy is the most common complication in diabetic patients relates to high expression of VEGF and microaneurysms. Scutellarin (Scu) turned out to be effective against diabetes related vascular endothelial cell dysfunction. However, its clinical applications have been limited by its low bioavailability. In this study, we formulated and characterized a novel intestinal target nanoparticle carrier based on amphiphilic chitosan derivatives (Chit-DC-VB12) loaded with scutellarin to enhance its bioavailability and then evaluated its therapeutic effect in experimental diabetic retinopathy model. Chit-DC-VB12 nanoparticles showed low toxicity toward the human colon adenocarcinoma (Caco-2) cells and zebra fish within concentration of 250 μg/ml, owing to good biocompatibility of chitosan. The scutellarin-loaded Chit-DC-VB12 nanoparticles (Chit-DC-VB12-Scu) were then prepared by self-assembly in aqueous solution. Scanning electron microscopy and dynamic light scattering analysis indicated that the Chit-DC-VB12-Scu nanoparticles were spherical particles in the sizes ranging from 150 to 250 nm. The Chit-DC-VB12-Scu nanoparticles exhibited high permeation in Caco-2 cell, indicated it could be beneficial to be absorbed in humans. We also found that Chit-DC-VB12 nanoparticles had a high cellular uptake. Bioavailability studies were performed in Sprague-Dawley rats, which present the area under the curve of scutellarin of Chit-DC-VB12-Scu was two to threefolds greater than that of free scutellarin alone. Further to assess the therapeutic efficacy of diabetic retinopathy, we showed Chit-DC-VB12-Scu down-regulated central retinal artery resistivity index and the expression of angiogenesis proteins (VEGF, VEGFR2, and vWF) of retinas in type II diabetic rats. Chit-DC-VB12 nanoparticles loaded with scutellarin have better bioavailability and cellular uptake efficiency than Scu, while Chit-DC-VB12-Scu nanoparticles alleviated the structural disorder of intraretinal neovessels in the retina induced by diabetes, and it also inhibited the retinal neovascularization via down-regulated the expression of angiogenesis proteins. In conclusion, the Chit-DC-VB12 nanoparticles enhanced scutellarin oral delivery efficacy and exhibited potential as small intestinal target promising nano-carriers for treatment of type II diabetes induced-retinopathy.

  17. Erwinia teleogrylli sp. nov., a Bacterial Isolate Associated with a Chinese Cricket

    PubMed Central

    Liu, Bo; Luo, Jin; Li, Wei; Long, Xiu-Feng; Zhang, Yu-Qin; Zeng, Zhi-Gang; Tian, Yong-Qiang

    2016-01-01

    A bacterial isolate (SCU-B244T) was obtained in China from crickets (Teleogryllus occipitalis) living in cropland deserted for approximately 10 years. The isolated bacteria were Gram-negative, facultatively anaerobic, oxidase-negative rods. A preliminary analysis of the 16S rRNA gene sequence indicated that the strain belongs to either the genus Erwinia or Pantoea. Analysis of multilocus sequence typing based on concatenated partial atpD, gyrB and infB gene sequences and physiological and biochemical characteristics indicated that the strain belonged to the genus Erwinia, as member of a new species as it was distinct from other known Erwinia species. Further analysis of the 16S rRNA gene showed SCU-B244T to have 94.71% identity to the closest species of that genus, Erwinia oleae (DSM 23398T), which is below the threshold of 97% used to discriminate bacterial species. DNA-DNA hybridization results (5.78±2.52%) between SCU-B244T and Erwinia oleae (DSM 23398T) confirmed that SCU-B244T and Erwinia oleae (DSM 23398T) represent different species combined with average nucleotide identity values which range from 72.42% to 74.41. The DNA G+C content of SCU-B244T was 55.32 mol%, which also differs from that of Erwinia oleae (54.7 to 54.9 mol%). The polyphasic taxonomic approach used here confirmed that the strain belongs to the Erwinia group and represents a novel species. The name Erwinia teleogrylli sp. nov. is proposed for this novel taxon, for which the type strain is SCU-B244T (= CGMCC 1.12772T = DSM 28222T = KCTC 42022T). PMID:26800121

  18. Long Duration Exposure Facility (LDEF) experiment M0003 meteoroid and debris survey

    NASA Technical Reports Server (NTRS)

    Meshishnek, M. J.; Gyetvay, S. R.; Paschen, K. W.; Coggi, J. M.

    1993-01-01

    A survey of the meteoroid and space debris impacts on LDEF experiment M0003 was performed. The purpose of this survey was to document significant impact phenomenology and to obtain impact crater data for comparison to current space debris and micrometeoroid models. The survey consists of the following: photomicrographs of significant impacts in a variety of material types; accurate measurements of impact crater coordinates and dimensions for selected experiment surfaces; and databasing of the crater data for reduction, manipulation, and comparison to models. Large area surfaces that were studied include the experiment power and data system (EPDS) sunshields, environment exposure control canister (EECC) sunshields, and the M0003 signal conditioning unit (SCU) covers. Crater diameters down to 25 microns were measured and cataloged. Both leading (D8) and trailing (D4) edge surfaces were studied and compared. The EPDS sunshields are aluminum panels painted with Chemglaze A-276 white thermal control paint, the EECC sunshields are chromic acid-anodized aluminum, and the SCU covers are aluminum painted with S13GLO white thermal control paint. Typical materials that have documented impacts are metals, glasses and ceramics, composites, polymers, electronic materials, and paints. The results of this survey demonstrate the different response of materials to hypervelocity impacts. Comparison of the survey data to curves derived from the Kessler debris model and the Cour-Palais micrometeoroid model indicates that these models overpredict small impacts (less than 100 micron) and may underpredict large impacts (greater than 1000 micron) while having fair to good agreement for the intermediate impacts. Comparison of the impact distributions among the various surfaces indicates significant variations, which may be a function of material response effects, or in some cases surface roughness. Representative photographs and summary graphs of the impact data are presented.

  19. Development and operating experience of a short-period superconducting undulator at the Advanced Photon Source

    DOE PAGES

    Ivanyushenkov, Y.; Harkay, K.; Abliz, M.; ...

    2015-04-01

    In this study, a decade-long effort at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL) on development of superconducting undulators culminated in December 2012 with the installation of the first superconducting undulator “SCU0” into Sector 6 of the APS storage ring. The device was commissioned in January 2013 and has been in user operation since. This paper presents the magnetic and cryogenic design of the SCU0 together with the results of stand-alone cold tests. The initial commissioning and characterization of SCU0 as well as its operating experience in the APS storage ring are described.

  20. Effect of water storage on ultimate tensile strength and mass changes of universal adhesives.

    PubMed

    Bahrololumi, Nazanin; Beglou, Amirreza; Najafi-Abrandabadi, Ahmad; Sadr, Alireza; Sheikh-Al-Eslamian, Seyedeh-Mahsa; Ghasemi, Amir

    2017-01-01

    The aim of the present study was to evaluate the influence of water storage on micro tensile strength (µTS) and mass changes (MC) of two universal adhesives. 10 disk-shaped specimens were prepared for each adhesive; Scotchbond Universal (SCU) All-Bond Universal (ABU) and Adper Single Bond 2 (SB2). At the baseline and after 1 day and 28 days of water storage, their mass were measured and compared to estimate water sorption and solubility. For µTS test, 20 dumbbell shaped specimens were also prepared for each adhesive in two subgroups of 1 day and 28 days water storage. MC was significantly lower for SCU and ABU than SB2 ( P < 0.05) at both time intervals. In all three adhesives, the MC was significantly lower at 28 days compared to that at 1 day ( P < 0.05). Similarly, µTS was significantly higher for SCU and ABU than SB2 at both storage intervals ( P < 0.05). After 28 days, µTS increased significantly for universal adhesives ( P < 0.05). MC and µTS of adhesives were both material and time dependent when stored in water; both universal adhesives showed less water sorption and higher values of µTS than the control group. Key words: Absorption, dental adhesives, dentin-bonding agents, solubility, tensile strength.

  1. Fabrication and assembly of a superconducting undulator for the advanced photon source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasse, Quentin; Fuerst, J. D.; Ivanyushenkov, Y.

    2014-01-29

    A prototype superconducting undulator magnet (SCU0) has been built at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL) and has successfully completed both cryogenic performance and magnetic measurement test programs. The SCU0 closed loop, zero-boil-off cryogenic system incorporates high temperature superconducting (HTS) current leads, cryocoolers, a LHe reservoir supplying dual magnetic cores, and an integrated cooled beam chamber. This system presented numerous challenges in the design, fabrication, and assembly of the device. Aspects of this R and D relating to both the cryogenic and overall assembly of the device are presented here. The SCU0 magnet has been installedmore » in the APS storage ring.« less

  2. The BepiColombo/SERENA Integrated Test Campaign

    NASA Astrophysics Data System (ADS)

    Orsini, Stefano; De Angelis, Elisabetta; Livi, Stefano; Lichtenegger, Herbert; Barabash, Stas; Milillo, Anna; Wurz, Peter; Olivieri, Angelo; D'Arcio, Luigi; Phillips, Mark; Laky, Gunter; Wieser, Martin; Camozzi, Fabio; Di Lellis, Andrea M.; Mura, Alessandro; Lazzarotto, Francesco; Aronica, Alessandro; Rispoli, Rosanna; Verolli, Nello; Piazza, Daniele

    2017-04-01

    The activities related to the BepiColombo/MPO/SERENA Integrated Test (SIT, held in February 2017 by the vacuum facility at the University of Bern, CH) are presented. This campaign is a unique opportunity to test the experiment performances, with all the four flight-spare instruments of SERENA (ELENA, STROFIO, PICAM, AND MIPA, simultaneously operated by the System Control Unit (SCU), in a fully operational configuration. The test is focused on the On-Board Commanding Procedure and on the Science Operation Basic Procedure, with the goal of providing a comprehensive picture of the on-board S/W facility both in nominal and more resource demanding conditions. Such a test is a powerful tool for allowing SERENA to perform the best possible observation of the particle populations surrounding Mercury.

  3. Fully EMU suited MS Peterson and MS Musgrave in airlock

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Fully extravehicular mobility unit (EMU) suited Mission Specialist (MS) Peterson (wearing glasses) and MS Musgrave with service and cooling umbilical (SCU) connected to their displays and control modules (DCMs) participate in airlock prebreathe procedures. Three-fourths of the STS-6 astronaut crew appear in this unusual 35mm frame exposed in the airlock of the Earth-orbiting Challenger, Orbiter Vehicle (OV) 099. Musgrave's helmet visor encompasses all the action in the frame. Peterson is reflected on the right side of Musgrave's visor with Pilot Bobko, wearing conventional onboard clothing and photographing, the activity appearing at the center of the frame. The reversed numbers (1 and 2) in the mirrored image represents the extravehicular activity (EVA) designations for the two mission specialists.

  4. Two Axis Pointing System (TAPS) attitude acquisition, determination, and control

    NASA Technical Reports Server (NTRS)

    Azzolini, John D.; Mcglew, David E.

    1990-01-01

    The Two Axis Pointing System (TAPS) is a 2 axis gimbal system designed to provide fine pointing of Space Transportation System (STS) borne instruments. It features center-of-mass instrument mounting and will accommodate instruments of up to 1134 kg (2500 pounds) which fit within a 1.0 by 1.0 by 4.2 meter (40 by 40 by 166 inch) envelope. The TAPS system is controlled by a microcomputer based Control Electronics Assembly (CEA), a Power Distribution Unit (PDU), and a Servo Control Unit (SCU). A DRIRU-II inertial reference unit is used to provide incremental angles for attitude propagation. A Ball Brothers STRAP star tracker is used for attitude acquisition and update. The theory of the TAPS attitude determination and error computation for the Broad Band X-ray Telescope (BBXRT) are described. The attitude acquisition is based upon a 2 star geometric solution. The acquisition theory and quaternion algebra are presented. The attitude control combines classical position, integral and derivative (PID) control with techniques to compensate for coulomb friction (bias torque) and the cable harness crossing the gimbals (spring torque). Also presented is a technique for an adaptive bias torque compensation which adjusts to an ever changing frictional torque environment. The control stability margins are detailed, with the predicted pointing performance, based upon simulation studies. The TAPS user interface, which provides high level operations commands to facilitate science observations, is outlined.

  5. Tyrosine requirement during the rapid catch-up growth phase of recovery from severe childhood undernutrition

    USDA-ARS?s Scientific Manuscript database

    The requirement for aromatic amino acids, during the rapid catch-up in weight phase of recovery from severe childhood under nutrition (SCU) is not clearly established. As a first step, the present study aimed to estimate the tyrosine requirement of children with SCU during the catch-up growth phase ...

  6. [Characteristics of ammonia volatilization and nitrous oxide emission from a paddy soil under continuous application of different slow/controlled release urea.

    PubMed

    Sun, Xiang Xin; Li, Dong Po; Wu, Zhi Jie; Cui, Ya Lan; Han, Mei; Li, Yong Hua; Yang, De Fu; Cui, Yong Kun

    2016-06-01

    The characteristics of ammonia volatilization and nitrous oxide emission from a paddy soil were examined under 9-year application of different slow/controlled release urea with the common large granule urea (U) as the control. The results showed that compared with the control, all slow/controlled release urea treatments, except 25.8% increase of ammonia volatilization under 1% 3,4-dimethylpyrazole phosphate (DMPP)+U, could decrease the ammonia volatilization. Polymer coated urea (PCU) dominated the highest reduction of 73.4% compared to U, followed by sulfur coated urea (SCU) (72.2%), 0.5% N-(N-butyl) thiophosphoric triamide (NBPT)+1% DMPP+U (71.9%), 1% hydroquinone (HQ)+3% dicyandiamide (DCD)+U (46.9%), 0.5% NBPT+U (43.2%), 1% HQ +U (40.2%), 3% DCD+U (25.5%), and the ammonia volatilization under different slow/controlled release urea treatments were statistically lower than that of U (P<0.05). 1% DMPP+U caused the lowest emission of N 2 O under different slow/controlled release urea treatments. The slow/controlled release urea also had a significant potential of N 2 O emission reduction: 1% DMPP+U showed the highest reduction of 74.9% compared to U, followed by PCU (62.1%), 1% HQ+3% DCD+U (54.7%), 0.5% NBPT+1% DMPP+U (42.2%), 3% DCD+U (35.9%), 1% HQ +U (28.9%), 0.5% NBPT+U (17.7%), SCU (14.5%), and N 2 O emissions under different slow/controlled release urea treatments were statistically lower than that of U (P<0.05). The comprehensive analysis showed that 0.5% NBPT+1% DMPP+U, SCU and PCU had similar effects on decreasing the ammonia volatilization and N 2 O emission and were remarkably better than the other treatments. The slow release urea with the combination of urease and nitrification inhibitors should be the first choice for reducing N loss and environmental pollution in paddy field, in view of the higher costs of coated urea fertilizers.

  7. Effect of water storage on ultimate tensile strength and mass changes of universal adhesives

    PubMed Central

    Bahrololumi, Nazanin; Najafi-Abrandabadi, Ahmad; Sadr, Alireza; Sheikh-Al-Eslamian, Seyedeh-Mahsa; Ghasemi, Amir

    2017-01-01

    Background The aim of the present study was to evaluate the influence of water storage on micro tensile strength (µTS) and mass changes (MC) of two universal adhesives. Material and Methods 10 disk-shaped specimens were prepared for each adhesive; Scotchbond Universal (SCU) All-Bond Universal (ABU) and Adper Single Bond 2 (SB2). At the baseline and after 1 day and 28 days of water storage, their mass were measured and compared to estimate water sorption and solubility. For µTS test, 20 dumbbell shaped specimens were also prepared for each adhesive in two subgroups of 1 day and 28 days water storage. Results MC was significantly lower for SCU and ABU than SB2 (P < 0.05) at both time intervals. In all three adhesives, the MC was significantly lower at 28 days compared to that at 1 day (P < 0.05). Similarly, µTS was significantly higher for SCU and ABU than SB2 at both storage intervals (P < 0.05). After 28 days, µTS increased significantly for universal adhesives (P < 0.05). Conclusions MC and µTS of adhesives were both material and time dependent when stored in water; both universal adhesives showed less water sorption and higher values of µTS than the control group. Key words:Absorption, dental adhesives, dentin-bonding agents, solubility, tensile strength. PMID:28149468

  8. Shallow cumulus rooted in photosynthesis

    NASA Astrophysics Data System (ADS)

    Vila-Guerau Arellano, J.; Ouwersloot, H.; Horn, G.; Sikma, M.; Jacobs, C. M.; Baldocchi, D.

    2014-12-01

    We investigate the interaction between plant evapotranspiration, controlled by photosynthesis (for a low vegetation cover by C3 and C4 grasses), and the moist thermals that are responsible for the formation and development of shallow cumulus clouds (SCu). We perform systematic numerical experiments at fine spatial scales using large-eddy simulations explicitly coupled to a plant-physiology model. To break down the complexity of the vegetation-atmospheric system at the diurnal scales, we design the following experiments with increasing complexity: (a) clouds that are transparent to radiation, (b) clouds that shade the surface from the incoming shortwave radiation and (c) plant stomata whose apertures react with an adjustment in time to cloud perturbations. The shading by SCu leads to a strong spatial variability in photosynthesis and the surface energy balance. As a result, experiment (b) simulates SCu that are characterized by less extreme and less skewed values of the liquid water path and cloud-base height. These findings are corroborated by the calculation of characteristics lengths scales of the thermals and clouds using autocorrelation and spectral analysis methods. We find that experiments (a) and (b) are characterized by similar cloud cover evolution, but different cloud population characteristics. Experiment (b), including cloud shading, is characterized by smaller clouds, but closer to each other. By performing a sensitivity analysis on the exchange of water vapor and carbon dioxide at the canopy level, we show that the larger water-use efficiency of C4 grass leads to two opposing effects that directly influence boundary-layer clouds: the thermals below the clouds are more vigorous and deeper driven by a larger buoyancy surface flux (positive effect), but are characterized by less moisture content (negative effect). We conclude that under the investigated mid-latitude atmospheric and well-watered soil conditions, SCu over C4 grass fields is characterized by larger cloud cover and an enhanced liquid water path compared to C3 grass fields.

  9. Antibodies Against Three Forms of Urokinase

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R.; Atassi, M. Zouhair

    2007-01-01

    Antibodies that bind to preselected regions of the urokinase molecule have been developed. These antibodies can be used to measure small quantities of each of three molecular forms of urokinase that could be contained in microsamples or conditioned media harvested from cultures of mammalian cells. Previously available antibodies and assay techniques do not yield both clear distinctions among, and measurements of, all three forms. Urokinase is a zymogen that is synthesized in a single-chain form, called ScuPA, which is composed of 411 amino acid residues (see figure). ScuPA has very little enzyme activity, but it can be activated in two ways: (1) by cleavage of the peptide bond lysine 158/isoleucine 159 and the loss of lysine 158 to obtain the high molecular-weight (HMW) form of the enzyme or (2) by cleavage of the bond lysine 135/lysine 136 to obtain the low-molecular-weight (LMW) form of the enzyme. The antibodies in question were produced in mice and rabbits by use of peptides as immunogens. The peptides were selected to obtain antibodies that bind to regions of ScuPA that include the lysine 158/isoleucine 159 and the lysine 135/lysine 136 bonds. The antibodies include monoclonal and polyclonal ones that yield indications as to whether either of these bonds is intact. The polyclonal antibodies include ones that preferentially bind to the HMW or LMW forms of the urokinase molecule. The monoclonal antibodies include ones that discriminate between the ScuPA and the HMW form. A combination of these molecular-specific antibodies will enable simultaneous assays of the ScuPA, HMW, and LMW forms in the same specimen of culture medium.

  10. Undergraduate Research Program Between SCU and SOFIA

    NASA Astrophysics Data System (ADS)

    Kulas, Kristin Rose; Andersson, B.-G.

    2018-06-01

    We present results on an undergraduate research program run in collaboration between Santa Clara University (SCU), a predominately undergraduate liberal arts college and the SOFIA Science Center/USRA. We have started a synergistic program between SCU and SOFIA (located at NASA Ames) where the students are able to be fully immersed in astronomical research; from helping to write telescope observing proposal; to observing at a world-class telescope; to reducing and analyzing the data that they acquired and ultimately to presenting/publishing their findings. A recently awarded NSF collaborative grant will allow us to execute and expand this program over the next several years. In this poster we present some of our students research and their success after the program. In addition, we discuss how a small university can actively collaborate with a large government-funded program like SOFIA, funded by NASA.

  11. Are mutagenic non D-loop direct repeat motifs in mitochondrial DNA under a negative selection pressure?

    PubMed Central

    Lakshmanan, Lakshmi Narayanan; Gruber, Jan; Halliwell, Barry; Gunawan, Rudiyanto

    2015-01-01

    Non D-loop direct repeats (DRs) in mitochondrial DNA (mtDNA) have been commonly implicated in the mutagenesis of mtDNA deletions associated with neuromuscular disease and ageing. Further, these DRs have been hypothesized to put a constraint on the lifespan of mammals and are under a negative selection pressure. Using a compendium of 294 mammalian mtDNA, we re-examined the relationship between species lifespan and the mutagenicity of such DRs. Contradicting the prevailing hypotheses, we found no significant evidence that long-lived mammals possess fewer mutagenic DRs than short-lived mammals. By comparing DR counts in human mtDNA with those in selectively randomized sequences, we also showed that the number of DRs in human mtDNA is primarily determined by global mtDNA properties, such as the bias in synonymous codon usage (SCU) and nucleotide composition. We found that SCU bias in mtDNA positively correlates with DR counts, where repeated usage of a subset of codons leads to more frequent DR occurrences. While bias in SCU and nucleotide composition has been attributed to nucleotide mutational bias, mammalian mtDNA still exhibit higher SCU bias and DR counts than expected from such mutational bias, suggesting a lack of negative selection against non D-loop DRs. PMID:25855815

  12. OPERATIONAL EXPERIENCE WITH FAST FIBER-OPTIC BEAM LOSS MONITORS FOR THE ADVANCED PHOTON SOURCE STORAGE RING SUPERCONDUCTING UNDULATORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooling, J.; Harkay, K.; Sajaev, V.

    Fast fiber-optic (FFO) beam loss monitors (BLMs) installed with the first two superconducting undulators (SCUs) in the Advanced Photon Source storage ring have proven to be a useful diagnostic for measuring deposited charge (energy) during rapid beam loss events. The first set of FFOBLMs were installed outside the cryostat of the short SCU, a 0.33-m long device, above and below the beam centerline. The second set are mounted with the first 1.1-mlong SCU within the cryostat, on the outboard and inboard sides of the vacuum chamber. The next 1.1-m-long SCU is scheduled to replace the short SCU later in 2016more » and will be fitted with FFOBLMs in a manner similar to original 1.1-m device. The FFOBLMs were employed to set timing and voltage for the abort kicker (AK) system. The AK helps to prevent quenching of the SCUs during beam dumps [1] by directing the beam away from the SC magnet windings. The AK is triggered by the Machine Protection System (MPS). In cases when the AK fails to prevent quenching, the FFOBLMs show that losses often begin before detection by the MPS.« less

  13. Innovative dementia care: functional status over time of persons with Alzheimer disease in a residential care centre compared to special care units.

    PubMed

    Warren, S; Janzen, W; Andiel-Hett, C; Liu, L; McKim, H R; Schalm, C

    2001-01-01

    Residential care centres (RCCs) for persons with Alzheimer disease are increasing worldwide, but there are few studies that compare the functional outcomes of RCC residents to residents of other types of continuing care settings. This study compared residents of the first Canadian RCC on physical, cognitive, behavioural and emotional functioning 6, 12 and 18 months after admission to residents of special care units (SCUs) operated by the same continuing care provider. SCU residents were initially functioning lower than RCC residents on most outcome measures and these differences persisted over time. Resident functioning declined over time regardless of care setting and, when the initial status was controlled for, the rates of decline were similar. However, RCC residents experienced greater independence/freedom of choice, fewer physical or psychotropic medication restraints and were more active, which may have enhanced their quality of life. Copyright 2001 S. Karger AG, Basel

  14. ARPEFS as an analytic technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schach von Wittenau, A.E.

    1991-04-01

    Two modifications to the ARPEFS technique are introduced. These are studied using p(2 {times} 2)S/Cu(001) as a model system. The first modification is the obtaining of ARPEFS {chi}(k) curves at temperatures as low as our equipment will permit. While adding to the difficulty of the experiment, this modification is shown to almost double the signal-to-noise ratio of normal emission p(2 {times} 2)S/Cu(001) {chi}(k) curves. This is shown by visual comparison of the raw data and by the improved precision of the extracted structural parameters. The second change is the replacement of manual fitting of the Fourier filtered {chi}(k) curves bymore » the use of the simplex algorithm for parameter determination. Again using p(2 {times} 2)S/Cu(001) data, this is shown to result in better agreement between experimental {chi}(k) curves and curves calculated based on model structures. The improved ARPEFS is then applied to p(2 {times} 2)S/Ni(111) and ({radical}3 {times} {radical}3) R30{degree}S/Ni(111). For p(2 {times} 2)S/Cu(001) we find a S-Cu bond length of 2.26 {Angstrom}, with the S adatom 1.31 {Angstrom} above the fourfold hollow site. The second Cu layer appears to be corrugated. Analysis of the p(2 {times} 2)S/Ni(111) data indicates that the S adatom adatom adsorbs onto the FCC threefold hollow site 1.53 {Angstrom} above the Ni surface. The S-Ni bond length is determined to be 2.13 {Angstrom}, indicating an outwards shift of the first layer Ni atoms. We are unable to assign a unique structure to ({radical}3 {times} {radical}3)R30{degree}S/Ni(111). An analysis of the strengths and weaknesses of ARPEFS as an experimental and analytic technique is presented, along with a summary of problems still to be addressed.« less

  15. Family caregiver satisfaction with the nursing home after placement of a relative with dementia.

    PubMed

    Tornatore, Jane B; Grant, Leslie A

    2004-03-01

    This article examines family caregiver satisfaction after nursing home placement of a relative with Alzheimer disease or a related dementia. Determining what contributes to family caregiver satisfaction is a critical step toward implementing effective quality improvement strategies. A stress process model is used to study caregiver satisfaction among 285 family caregivers in relation to primary objective stressors (stage of dementia, length of stay, length of time in caregiving role, visitation frequency, involvement in nursing home, and involvement in hands-on care), subjective stressors (expectations for care), caregiver characteristics (education, marital status, familial relationship, workforce participation, distance from nursing home, and age), and organizational resources (rural/urban location, profit/nonprofit ownership, special care unit [SCU] designation, and custodial unit designation). SAS PROC MIXED is used in a multilevel analysis. Higher satisfaction is associated with earlier stage of dementia, greater length of time involved in caregiving prior to institutionalization, higher visitation frequency, less involvement in hands-on care, greater expectations for care, and less workforce participation. Multilevel analysis showed that primary stressors are the strongest predictors of satisfaction. Only one caregiver characteristic (work participation) and one organizational resource (rural/urban location) predict satisfaction. SCU designation was unrelated to satisfaction, perhaps because SCUs have less to offer residents in more advanced as opposed to earlier stages of Alzheimer disease. If family satisfaction is to be achieved, family presence in a nursing home needs to give caregivers a sense of positive involvement and influence over the care of their relative.

  16. Characterization and long term operation of a novel superconducting undulator with 15 mm period length in a synchrotron light source

    NASA Astrophysics Data System (ADS)

    Casalbuoni, S.; Cecilia, A.; Gerstl, S.; Glamann, N.; Grau, A. W.; Holubek, T.; Meuter, C.; de Jauregui, D. Saez; Voutta, R.; Boffo, C.; Gerhard, Th.; Turenne, M.; Walter, W.

    2016-11-01

    A new cryogen-free full scale (1.5 m long) superconducting undulator with a period length of 15 mm (SCU15) has been successfully tested in the ANKA storage ring. This represents a very important milestone in the development of superconducting undulators for third and fourth generation light sources carried on by the collaboration between the Karlsruhe Institute of Technology and the industrial partner Babcock Noell GmbH. SCU15 is the first full length device worldwide that with beam reaches a higher peak field than what expected with the same geometry (vacuum gap and period length) with an ideal cryogenic permanent magnet undulator built with the best material available PrFeB. After a summary on the design and main parameters of the device, we present here the characterization in terms of spectral properties and the long term operation of the SCU15 in the ANKA storage ring.

  17. Supercritical Water Mixture (SCWM) Experiment in the High Temperature Insert-Reflight (HTI-R)

    NASA Technical Reports Server (NTRS)

    Hicks, Michael C.; Hegde, Uday G.; Garrabos, Yves; Lecoutre, Carole; Zappoli, Bernard

    2013-01-01

    Current research on supercritical water processes on board the International Space Station (ISS) focuses on salt precipitation and transport in a test cell designed for supercritical water. This study, known as the Supercritical Water Mixture Experiment (SCWM) serves as a precursor experiment for developing a better understanding of inorganic salt precipitation and transport during supercritical water oxidation (SCWO) processes for the eventual application of this technology for waste management and resource reclamation in microgravity conditions. During typical SCWO reactions any inorganic salts present in the reactant stream will precipitate and begin to coat reactor surfaces and control mechanisms (e.g., valves) often severely impacting the systems performance. The SCWM experiment employs a Sample Cell Unit (SCU) filled with an aqueous solution of Na2SO4 0.5-w at the critical density and uses a refurbished High Temperature Insert, which was used in an earlier ISS experiment designed to study pure water at near-critical conditions. The insert, designated as the HTI-Reflight (HTI-R) will be deployed in the DECLIC (Device for the Study of Critical Liquids and Crystallization) Facility on the International Space Station (ISS). Objectives of the study include measurement of the shift in critical temperature due to the presence of the inorganic salt, assessment of the predominant mode of precipitation (i.e., heterogeneously on SCU surfaces or homogeneously in the bulk fluid), determination of the salt morphology including size and shapes of particulate clusters, and the determination of the dominant mode of transport of salt particles in the presence of an imposed temperature gradient. Initial results from the ISS experiments will be presented and compared to findings from laboratory experiments on the ground.

  18. Losses of surface runoff, total solids, and nitrogen during bermudagrass establishment on levee embankments.

    PubMed

    Burwell, Robert W; Beasley, Jeffrey S; Gaston, Lewis A; Borst, Steven M; Sheffield, Ron E; Strahan, Ron E; Munshaw, Gregg C

    2011-01-01

    Nutrient and sediment runoff from newly constructed levee embankments pose a threat to water quality during soft armor vegetation establishment. Research was initiated in 2008 and 2009 to evaluate the effect of bermudagrass ( L.) coverage and N source on nutrient and sediment runoff from levee embankments during establishment. Bermudagrass plots were seeded at 195.3 kg pure live seed ha and fertilized at 50 kg N ha using a water-soluble N source, urea or NH-NO, or slow-release N source, S-coated urea (SCU) or urea formaldehyde (UF), with controls unfertilized. Vegetative cover percentage, time until the onset of runoff, runoff volume, and total solids (TS), NO-N, and NH-N concentrations were measured from simulated and natural rainfall events for 70 d in 2008 and 56 d in 2009. Bermudagrass at 90% grass cover delayed the onset of runoff an additional 441 to 538 s and reduced runoff volumes 74 to 84% of that exhibited at 10% grass cover. Nitrogen fertilizers did not accelerate bermudagrass growth sufficiently, however, to reduce TS loading compared with unfertilized bermudagrass in either year of the study. The application of urea and SCU resulted in cumulative N losses of 2.45 and 3.13 kg ha compared with 1.59 kg ha from the unfertilized bermudagrass in 2008, and 1.73 kg ha from NH-NO vs. 0.24 kg ha from controls in 2009. Only UF increased bermudagrass establishment without increasing cumulative N losses compared with unfertilized bermudagrass. Therefore, the benefit of greater erosion and runoff resistance expected from N-accelerated vegetative growth did not occur but had the unintended consequence of higher N losses when water-soluble N and SCU fertilizers were applied. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  19. Emergence of Uranium as a Distinct Metal Center for Building Intrinsic X-ray Scintillators.

    PubMed

    Wang, Yaxing; Yin, Xuemiao; Liu, Wei; Xie, Jian; Chen, Junfeng; Silver, Mark A; Sheng, Daopeng; Chen, Lanhua; Diwu, Juan; Liu, Ning; Chai, Zhifang; Albrecht-Schmitt, Thomas E; Wang, Shuao

    2018-06-25

    The combination of high atomic number and high oxidation state in U VI materials gives rise to both high X-ray attenuation efficiency and intense green luminescence originating from ligand-to-metal charge transfer. These two features suggest that U VI materials might act as superior X-ray scintillators, but this postulate has remained substantially untested. Now the first observation of intense X-ray scintillation in a uranyl-organic framework (SCU-9) that is observable by the naked eye is reported. Combining the advantage in minimizing the non-radiative relaxation during the X-ray excitation process over those of inorganic salts of uranium, SCU-9 exhibits a very efficient X-ray to green light luminescence conversion. The luminescence intensity shows an essentially linear correlation with the received X-ray intensity, and is comparable with that of commercially available CsI:Tl. SCU-9 possesses an improved X-ray attenuation efficiency (E>20 keV) as well as enhanced radiation resistance and decreased hygroscopy compared to CsI:Tl. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A second-generation superconducting undulator cryostat for the APS

    NASA Astrophysics Data System (ADS)

    Fuerst, J.; Hasse, Q.; Ivanyushenkov, Y.; Kasa, M.; Shiroyanagi, Y.

    2017-12-01

    A second-generation cryocooler-based cryostat has been designed and built to support a new helically wound superconducting undulator (SCU) magnet for the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The design represents an evolution of existing SCU cryostats currently in operation in the APS storage ring. Value engineering and lessons learned have resulted in a smaller, cheaper, and simpler cryostat design compatible with existing planar magnets as well as the new helically wound device. We describe heat load and quench response results, design and operational details, and the “build-to-spec” procurement strategy.

  1. Dose dependency of outcomes of intrapleural fibrinolytic therapy in new rabbit empyema models

    PubMed Central

    Florova, Galina; Azghani, Ali O.; Buchanan, Ann; Boren, Jake; Allen, Timothy; Rahman, Najib M.; Koenig, Kathleen; Chamiso, Mignote; Karandashova, Sophia; Henry, James; Idell, Steven

    2016-01-01

    The incidence of empyema (EMP) is increasing worldwide; EMP generally occurs with pleural loculation and impaired drainage is often treated with intrapleural fibrinolytic therapy (IPFT) or surgery. A number of IPFT options are used clinically with empiric dosing and variable outcomes in adults. To evaluate mechanisms governing intrapleural fibrinolysis and disease outcomes, models of Pasteurella multocida and Streptococcus pneumoniae were generated in rabbits and the animals were treated with either human tissue (tPA) plasminogen activator or prourokinase (scuPA). Rabbit EMP was characterized by the development of pleural adhesions detectable by chest ultrasonography and fibrinous coating of the pleura. Similar to human EMP, rabbits with EMP accumulated sizable, 20- to 40-ml fibrinopurulent pleural effusions associated with extensive intrapleural organization, significantly increased pleural thickness, suppression of fibrinolytic and plasminogen-activating activities, and accumulation of high levels of plasminogen activator inhibitor 1, plasminogen, and extracellular DNA. IPFT with tPA (0.145 mg/kg) or scuPA (0.5 mg/kg) was ineffective in rabbit EMP (n = 9 and 3 for P. multocida and S. pneumoniae, respectively); 2 mg/kg tPA or scuPA IPFT (n = 5) effectively cleared S. pneumoniae-induced EMP collections in 24 h with no bleeding observed. Although intrapleural fibrinolytic activity for up to 40 min after IPFT was similar for effective and ineffective doses of fibrinolysin, it was lower for tPA than for scuPA treatments. These results demonstrate similarities between rabbit and human EMP, the importance of pleural fluid PAI-1 activity, and levels of plasminogen in the regulation of intrapleural fibrinolysis and illustrate the dose dependency of IPFT outcomes in EMP. PMID:27343192

  2. Dose dependency of outcomes of intrapleural fibrinolytic therapy in new rabbit empyema models.

    PubMed

    Komissarov, Andrey A; Florova, Galina; Azghani, Ali O; Buchanan, Ann; Boren, Jake; Allen, Timothy; Rahman, Najib M; Koenig, Kathleen; Chamiso, Mignote; Karandashova, Sophia; Henry, James; Idell, Steven

    2016-08-01

    The incidence of empyema (EMP) is increasing worldwide; EMP generally occurs with pleural loculation and impaired drainage is often treated with intrapleural fibrinolytic therapy (IPFT) or surgery. A number of IPFT options are used clinically with empiric dosing and variable outcomes in adults. To evaluate mechanisms governing intrapleural fibrinolysis and disease outcomes, models of Pasteurella multocida and Streptococcus pneumoniae were generated in rabbits and the animals were treated with either human tissue (tPA) plasminogen activator or prourokinase (scuPA). Rabbit EMP was characterized by the development of pleural adhesions detectable by chest ultrasonography and fibrinous coating of the pleura. Similar to human EMP, rabbits with EMP accumulated sizable, 20- to 40-ml fibrinopurulent pleural effusions associated with extensive intrapleural organization, significantly increased pleural thickness, suppression of fibrinolytic and plasminogen-activating activities, and accumulation of high levels of plasminogen activator inhibitor 1, plasminogen, and extracellular DNA. IPFT with tPA (0.145 mg/kg) or scuPA (0.5 mg/kg) was ineffective in rabbit EMP (n = 9 and 3 for P. multocida and S. pneumoniae, respectively); 2 mg/kg tPA or scuPA IPFT (n = 5) effectively cleared S. pneumoniae-induced EMP collections in 24 h with no bleeding observed. Although intrapleural fibrinolytic activity for up to 40 min after IPFT was similar for effective and ineffective doses of fibrinolysin, it was lower for tPA than for scuPA treatments. These results demonstrate similarities between rabbit and human EMP, the importance of pleural fluid PAI-1 activity, and levels of plasminogen in the regulation of intrapleural fibrinolysis and illustrate the dose dependency of IPFT outcomes in EMP. Copyright © 2016 the American Physiological Society.

  3. Dual-stroke heat pump field performance

    NASA Astrophysics Data System (ADS)

    Veyo, S. E.

    1984-11-01

    Two nearly identical proprototype systems, each employing a unique dual-stroke compressor, were built and tested. One was installed in an occupied residence in Jeannette, Pa. It has provided the heating and cooling required from that time to the present. The system has functioned without failure of any prototypical advanced components, although early field experience did suffer from deficiencies in the software for the breadboard micro processor control system. Analysis of field performance data indicates a heating performance factor (HSPF) of 8.13 Stu/Wa, and a cooling energy efficiency (SEER) of 8.35 Scu/Wh. Data indicate that the beat pump is oversized for the test house since the observed lower balance point is 3 F whereas 17 F La optimum. Oversizing coupled with the use of resistance heat ot maintain delivered air temperature warmer than 90 F results in the consumption of more resistance heat than expected, more unit cycling, and therefore lower than expected energy efficiency. Our analysis indicates that with optimal mixing the dual stroke heat pump will yield as HSFF 30% better than a single capacity heat pump representative of high efficiency units in the market place today for the observed weather profile.

  4. Impact of S fertilizers on pore-water Cu dynamics and transformation in a contaminated paddy soil with various flooding periods.

    PubMed

    Yang, Jianjun; Zhu, Shenhai; Zheng, Cuiqing; Sun, Lijuan; Liu, Jin; Shi, Jiyan

    2015-04-09

    Impact of S fertilization on Cu mobility and transformation in contaminated paddy soils has been little reported. In this study, we investigated the dynamics and transformation of dissolved and colloidal Cu in the pore water of a contaminated paddy soil after applying ammonium sulphate (AS) and sulfur coated urea (SCU) with various flooding periods (1, 7 and 60 days). Compared to the control soil, the AS-treated soil released more colloidal and dissolved Cu over the entire flooding period, while the SCU-treated soil had lower colloidal Cu after 7-day flooding but higher colloidal and dissolved Cu after 60-day flooding. Microscopic X-ray fluorescence (μ-XRF) analysis found a close relationship between Fe and Cu distribution on soil colloids after 60-day flooding, implying the formation of colloidal Fe/Cu sulphide coprecipitates. Cu K-edge X-ray absorption near-edge structure (XANES) spectroscopy directly revealed the transformation of outer-sphere complexed Cu(II) species to Cu(II) sulphide and reduced Cu2O in the colloids of S-treated soils after 60-day flooding. These results demonstrated the great influence of S fertilization on pore-water Cu mobility by forming Cu sulphide under flooding conditions, which facilitated our understanding and control of Cu loss in contaminated paddy soils under S fertilization. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Twenty years of oxygenated treatment on Russian supercritical plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shitsman, M.E.

    1995-01-01

    The oxygenated treatment (OT) in Russia was first (1973-74) introduced at the 300 MWe Konakovo Supercritical units (SCU). The advantage of OT over AVT especially in rising the reliability of low-radiation boiler section (LRS) promoted to conversion the working units on OT and putting into operation the new SCUs directly with OT. All Russian supercritical plants, besides two of them, operate currently with OT. The conversion of units on OT doesn`t demand much expenditures. OT is simple and reliable. The OT introduction makes the main difficulty connected with the existance of stable stereotype for ammonia feed and supporting the oxygenmore » concentration in feedwater less than 5 ppb. The staff of two mentioned plants gave proof of devotion to AVT by its wide application in the USA and Japan. Now the units with once through boilers at these countries are intensively conversed on OT. It is possible to hope that this circumstance will dismiss at last the stereotype of oxygen fear.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broadbridge, Christine C.

    DOE grant used for partial fulfillment of necessary laboratory equipment for course enrichment and new graduate programs in nanotechnology at the four institutions of the Connecticut State University System (CSUS). Equipment in this initial phase included variable pressure scanning electron microscope with energy dispersive x-ray spectroscopy elemental analysis capability [at Southern Connecticut State University]; power x-ray diffractometer [at Central Connecticut State University]; a spectrophotometer and spectrofluorimeter [at Eastern Connecticut State University; and a Raman Spectrometer [at Western Connecticut State University]. DOE's funding was allocated for purchase and installation of this scientific equipment and instrumentation. Subsequently, DOE funding was allocated tomore » fund the curriculum, faculty development and travel necessary to continue development and implementation of the System's Graduate Certificate in Nanotechnology (GCNT) program and the ConnSCU Nanotechnology Center (ConnSCU-NC) at Southern Connecticut State University. All of the established outcomes have been successfully achieved. The courses and structure of the GCNT program have been determined and the program will be completely implemented in the fall of 2013. The instrumentation has been purchased, installed and has been utilized at each campus for the implementation of the nanotechnology courses, CSUS GCNT and the ConnSCU-NC. Additional outcomes for this grant include curriculum development for non-majors as well as faculty and student research.« less

  7. Characterization of high flux magnetized helium plasma in SCU-PSI linear device

    NASA Astrophysics Data System (ADS)

    Xiaochun, MA; Xiaogang, CAO; Lei, HAN; Zhiyan, ZHANG; Jianjun, WEI; Fujun, GOU

    2018-02-01

    A high-flux linear plasma device in Sichuan University plasma-surface interaction (SCU-PSI) based on a cascaded arc source has been established to simulate the interactions between helium and hydrogen plasma with the plasma-facing components in fusion reactors. In this paper, the helium plasma has been characterized by a double-pin Langmuir probe. The results show that the stable helium plasma beam with a diameter of 26 mm was constrained very well at a magnetic field strength of 0.3 T. The core density and ion flux of helium plasma have a strong dependence on the applied current, magnetic field strength and gas flow rate. It could reach an electron density of 1.2 × 1019 m-3 and helium ion flux of 3.2 × 1022 m-2 s-1, with a gas flow rate of 4 standard liter per minute, magnetic field strength of 0.2 T and input power of 11 kW. With the addition of -80 V applied to the target to increase the helium ion energy and the exposure time of 2 h, the flat top temperature reached about 530 °C. The different sizes of nanostructured fuzz on irradiated tungsten and molybdenum samples surfaces under the bombardment of helium ions were observed by scanning electron microscopy. These results measured in the SCU-PSI linear device provide a reference for International Thermonuclear Experimental Reactor related PSI research.

  8. Thermal Modeling and Cryogenic Design of a Helical Superconducting Undulator Cryostat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiroyanagi, Y.; Fuerst, J.; Hasse, Q.

    A conceptual design for a helical superconducting undulator (HSCU) for the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) has been completed. The device differs sufficiently from the existing APS planar superconducting undulator (SCU) design to warrant development of a new cryostat based on value engineering and lessons learned from the existing planar SCU. Changes include optimization of the existing cryocooler-based refrigeration system and thermal shield as well as cost reduction through the use of standard vacuum hardware. The end result is a design that provides significantly larger 4.2 K refrigeration margin in a smaller package for greater installationmore » flexibility in the APS storage ring. This paper presents ANSYS-based thermal analysis of the cryostat, including estimated static and dynamic« less

  9. Effects of decreased availability of sulfur amino acids in severe childhood undernutrition

    USDA-ARS?s Scientific Manuscript database

    In studies of glutathione (GSH) metabolism in children with severe childhood undernutrition (SCU), slower erythrocyte GSH synthesis in children with edema was associated with lower concentrations of cysteine, the rate-limiting precursor of GSH synthesis. This finding suggested a shortage of cysteine...

  10. Ereaders in Academic Libraries--A Literature Review

    ERIC Educational Resources Information Center

    Tees, Tracy

    2010-01-01

    This literature review describes the experiences of universities in their use of ereaders as textbook replacements and of academic libraries and their lending of ereaders. Information gained from this review will inform Southern Cross University (SCU) Library's forthcoming Ereader Project, which will trial the lending of ereaders as leisure…

  11. Resident-Assisted Montessori Programming (RAMP): use of a small group reading activity run by persons with dementia in adult day health care and long-term care settings.

    PubMed

    Skrajner, Michael J; Camp, Cameron J

    2007-01-01

    Six persons in the early to middle stages of dementia ("leaders") were trained in Resident-Assisted Montessori Programming (RAMP) to lead a reading activity for 22 persons with more advanced dementia ("participants") in an adult day health center (ADHC) and a special care unit (SCU) in a skilled nursing facility. Researchers assessed the leaders' abilities to learn and follow the procedures of leading a group, as well as their satisfaction with their roles. In addition, participants' engagement and affect were measured, both during standard activities programming and during client-led activities. Results of this study suggest that persons with dementia can indeed successfully lead small group activities, if several important prerequisites are met. Furthermore, the engagement and affect of participants was more positive in client-led activities than in standard activities programming.

  12. A Statewide Approach to Creating Veteran-Friendly Campuses

    ERIC Educational Resources Information Center

    Lokken, Jayne M.; Pfeffer, Donald S.; McAuley, James; Strong, Christopher

    2009-01-01

    One of the most consistent messages one hears from veterans on campus is the need for a strong sense of community and belonging. St. Cloud State University (SCSU), part of the Minnesota State Colleges and Universities system (MnSCU), is collaborating with the Minnesota Department of Veterans Affairs (MDVA) and the SCSU Student Veterans…

  13. 28 CFR 16.34 - Procedure to obtain change, correction or updating of identification records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION Production of FBI Identification Records in Response to... any entry on his/her record to the FBI, Criminal Justice Information Services (CJIS) Division, ATTN: SCU, Mod. D-2, 1000 Custer Hollow Road, Clarksburg, WV 26306. The FBI will then forward the challenge...

  14. 28 CFR 16.34 - Procedure to obtain change, correction or updating of identification records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION Production of FBI Identification Records in Response to... any entry on his/her record to the FBI, Criminal Justice Information Services (CJIS) Division, ATTN: SCU, Mod. D-2, 1000 Custer Hollow Road, Clarksburg, WV 26306. The FBI will then forward the challenge...

  15. 28 CFR 16.34 - Procedure to obtain change, correction or updating of identification records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION Production of FBI Identification Records in Response to... any entry on his/her record to the FBI, Criminal Justice Information Services (CJIS) Division, ATTN: SCU, Mod. D-2, 1000 Custer Hollow Road, Clarksburg, WV 26306. The FBI will then forward the challenge...

  16. 28 CFR 16.34 - Procedure to obtain change, correction or updating of identification records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION Production of FBI Identification Records in Response to... any entry on his/her record to the FBI, Criminal Justice Information Services (CJIS) Division, ATTN: SCU, Mod. D-2, 1000 Custer Hollow Road, Clarksburg, WV 26306. The FBI will then forward the challenge...

  17. 28 CFR 16.34 - Procedure to obtain change, correction or updating of identification records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION Production of FBI Identification Records in Response to... any entry on his/her record to the FBI, Criminal Justice Information Services (CJIS) Division, ATTN: SCU, Mod. D-2, 1000 Custer Hollow Road, Clarksburg, WV 26306. The FBI will then forward the challenge...

  18. Dental laboratory technology education in China: current situation and challenges.

    PubMed

    Zheng, Liwei; Yue, Li; Zhou, Min; Yu, Haiyang

    2013-03-01

    Modern dentistry and dental education in China were first introduced from abroad by Dr. Lindsay in 1907. However, advancements in the field of dental laboratory technology did not occur to the same degree in specialties such as prosthodontics and orthodontics. Since the 1990s, orders from abroad demanding dental appliances surged as the image of China as the "world's factory" strengthened. The assembly line model, in which technicians work like simple procedure workers, was rapidly applied to denture production, while the traditional education system and apprenticeship systems demonstrated little progress in these years. The lack of advancement in dental laboratory technology education caused insufficient development in China's dental technology industry. In order to alter the situation, a four-year dental laboratory technology undergraduate educational program was established in 2005 by West China School of Stomatology, Sichuan University (WCSS, SCU). This program was based on SCU's undergraduate education and WCSS's junior college education systems. The program introduced scientific methods in relevant subjects into laboratory technicians' training and made many improvements in the availability of trained faculty, textbooks, laboratory facilities, and curriculum.

  19. Higher Education in Times of Financial Distress: The Minnesota Experience

    ERIC Educational Resources Information Center

    Severns, Roger

    2012-01-01

    Like many states, Minnesota has incurred large budget deficits during the past two years. Those deficits have, in turn, led to changes in a number of areas of state government, particularly higher education. Faculty have incurred pay freezes and layoffs, programs have closed, and tuition increased. Campuses within the MnSCU system have been…

  20. The Impact of Gender on Decision Making among Customized Training Administrators within the Minnesota State Colleges and Universities System (MnSCU).

    ERIC Educational Resources Information Center

    Lane, Barry L.

    This paper presents a qualitative investigation of the impact of gender on administrator decision-making within the college environment. The research compared 5 male and 5 female college administrators from 10 different metropolitan campuses in the Minnesota State Colleges and Universities System. All were directors of customized training…

  1. Integrating interprofessional education in community-based learning activities: case study.

    PubMed

    Hosny, Somaya; Kamel, Mohamed H; El-Wazir, Yasser; Gilbert, John

    2013-01-01

    Faculty of Medicine/Suez Canal University (FOM/SCU) students are exposed to clinical practice in primary care settings within the community, in which they encounter patients and begin to work within interprofessional health teams. However, there is no planned curricular interaction with learners from other professions at the learning sites. As in other schools, FOM/SCU faces major challenges with the coordination of community-based education (CBE) program, which include the complexity of the design required for Interprofessional Education (IPE) as well as the attitudinal barriers between professions. The aim of the present review is to: (i) describe how far CBE activities match the requirements of IPE, (ii) explore opinions of graduates about the effectiveness of IPE activities, and (iii) present recommendations for improvement. Graduates find the overall outcome of their IPE satisfactory and believe that it produces physicians who are familiar with the roles of other professions and can work in synergy for the sake of better patient care. However, either a specific IPE complete module needs to be developed or more IPE specific objectives need to be added to current modules. Moreover, coordination with stakeholders from other health profession education institutes needs to be maximized to achieve more effective IPE.

  2. Molecular Simulations of Dynamic Processes of Solid Explosives

    DTIC Science & Technology

    2004-12-01

    compression. Therefore, we analyzed the dynamics of the energetic crystals RDX , HMX , HNIW and PETN under hydrostatic compression conditions using...for the RDX , HMX and HNIW crystals were found in good agreement with experimental values over the entire range of pressures investigated...Theoretical studies of the hydrostatic compression of RDX , HMX , HNIW, and PETN crystals, J. Phys. Chem. B 103, 6783. scu, D. C.; Rice, B. M. and

  3. Estimating Carbon Flux Phenology with Satellite-Derived Land Surface Phenology and Climate Drivers for Different Biomes: A Synthesis of AmeriFlux Observations

    PubMed Central

    Zhu, Wenquan; Chen, Guangsheng; Jiang, Nan; Liu, Jianhong; Mou, Minjie

    2013-01-01

    Carbon Flux Phenology (CFP) can affect the interannual variation in Net Ecosystem Exchange (NEE) of carbon between terrestrial ecosystems and the atmosphere. In this study, we proposed a methodology to estimate CFP metrics with satellite-derived Land Surface Phenology (LSP) metrics and climate drivers for 4 biomes (i.e., deciduous broadleaf forest, evergreen needleleaf forest, grasslands and croplands), using 159 site-years of NEE and climate data from 32 AmeriFlux sites and MODIS vegetation index time-series data. LSP metrics combined with optimal climate drivers can explain the variability in Start of Carbon Uptake (SCU) by more than 70% and End of Carbon Uptake (ECU) by more than 60%. The Root Mean Square Error (RMSE) of the estimations was within 8.5 days for both SCU and ECU. The estimation performance for this methodology was primarily dependent on the optimal combination of the LSP retrieval methods, the explanatory climate drivers, the biome types, and the specific CFP metric. This methodology has a potential for allowing extrapolation of CFP metrics for biomes with a distinct and detectable seasonal cycle over large areas, based on synoptic multi-temporal optical satellite data and climate data. PMID:24386441

  4. Removal of copper (II) from aqueous solutions by flotation using polyaluminum chloride silicate (PAX-XL60 S) as coagulant and carbonate ion as activator.

    PubMed

    Ghazy, S E; Mahmoud, I A; Ragab, A H

    2006-01-01

    Flotation is a separation technology for removing toxic heavy metal ions from aqueous solutions. Here a simple and rapid flotation procedure is presented for the removal of copper(II) from aqueous solutions. It is based on the use of polyaluminum chloride silicate (PAX-XL60 S) as coagulant and flocculent, carbonate ion as activator and oleic acid (HOL) as surfactant. Both ion and precipitate flotation are included depending on the solution pH. Ion and precipitate flotation in the aqueous HOL-PAX-XL60 S-Cu2+-CO3(2-) system gave powerful preferential removal of Cu2+ (F -100%) over the HOL-PAX-XL60 S-Cu2+ system containing no CO3(2+) ion (F approximately 86%). The role of CO3(2-) ion is also evident from decreasing the dose of PAX-XL60 S from 700 mg l(-1) to 200 mg l(-1). The other parameters, influencing the flotation process, namely: metal ion, surfactant and PAX-XL60 S concentrations, ionic strength, temperature and foreign ions were examined. Moreover, the procedure was successfully applied to recover Cu2+ ions from different volumes up to 11 and from natural water samples.

  5. Loss of EGFR-ASAP1 signaling in metastatic and unresectable hepatoblastoma.

    PubMed

    Ranganathan, Sarangarajan; Ningappa, Mylarappa; Ashokkumar, Chethan; Higgs, Brandon W; Min, Jun; Sun, Qing; Schmitt, Lori; Subramaniam, Shankar; Hakonarson, Hakon; Sindhi, Rakesh

    2016-12-02

    Hepatoblastoma (HBL), the most common childhood liver cancer is cured with surgical resection after chemotherapy or with liver transplantation if local invasion and multifocality preclude resection. However, variable survival rates of 60-80% and debilitating chemotherapy sequelae argue for more informed treatment selection, which is not possible by grading the Wnt-β-catenin over activity present in most HBL tumors. A hypothesis-generating whole transcriptome analysis shows that HBL tumors removed at transplantation are enriched most for cancer signaling pathways which depend predominantly on epidermal growth factor (EGF) signaling, and to a lesser extent, on aberrant Wnt-β-catenin signaling. We therefore evaluated whether EGFR, ASAP1, ERBB2 and ERBB4, which signal downstream after ligation of EGF, and which show aberrant expression in several other invasive cancers, would also predict HBL tumor invasiveness. Immunohistochemistry of HBL tumors (n = 60), which are histologically heterogeneous, shows that compared with well-differentiated fetal cells, less differentiated embryonal and undifferentiated small cells (SCU) progressively lose EGFR and ASAP1 expression. This trend is exaggerated in unresectable, locally invasive or metastatic tumors, in which embryonal tumor cells are EGFR-negative, while SCU cells are EGFR-negative and ASAP1-negative. Loss of EGFR-ASAP1 signaling characterizes undifferentiated and invasive HBL. EGFR-expressing HBL tumors present novel therapeutic targeting opportunities.

  6. Estimating Carbon Flux Phenology with Satellite-Derived Land Surface Phenology and Climate Drivers for Different Biomes: A Synthesis of AmeriFlux Observations

    DOE PAGES

    Zhu, Wenquan; Chen, Guangsheng; Jiang, Nan; ...

    2013-12-27

    Carbon Flux Phenology (CFP) can affect the interannual variation in Net Ecosystem Exchange (NEE) of carbon between terrestrial ecosystems and the atmosphere. In this paper, we proposed a methodology to estimate CFP metrics with satellite-derived Land Surface Phenology (LSP) metrics and climate drivers for 4 biomes (i.e., deciduous broadleaf forest, evergreen needleleaf forest, grasslands and croplands), using 159 site-years of NEE and climate data from 32 AmeriFlux sites and MODIS vegetation index time-series data. LSP metrics combined with optimal climate drivers can explain the variability in Start of Carbon Uptake (SCU) by more than 70% and End of Carbon Uptakemore » (ECU) by more than 60%. The Root Mean Square Error (RMSE) of the estimations was within 8.5 days for both SCU and ECU. The estimation performance for this methodology was primarily dependent on the optimal combination of the LSP retrieval methods, the explanatory climate drivers, the biome types, and the specific CFP metric. In conclusion, this methodology has a potential for allowing extrapolation of CFP metrics for biomes with a distinct and detectable seasonal cycle over large areas, based on synoptic multi-temporal optical satellite data and climate data.« less

  7. Neutron powder diffraction and high-pressure synchrotron x-ray diffraction study of tantalum nitrides

    NASA Astrophysics Data System (ADS)

    Feng, Lei-hao; Hu, Qi-wei; Lei, Li; Fang, Lei-ming; Qi, Lei; Zhang, Lei-lei; Pu, Mei-fang; Kou, Zi-li; Peng, Fang; Chen, Xi-ping; Xia, Yuan-hua; Kojima, Yohei; Ohfuji, Hiroaki; He, Duan-wei; Chen, Bo; Irifune, Tetsuo

    2018-02-01

    Not Available Project supported by the Research Foundation of Key Laboratory of Neutron Physics (Grant No. 2015BB03), the National Natural Science Foundation of China (Grant Nos. 11774247), the Science Foundation for Excellent Youth Scholars of Sichuan University (Grant No. 2015SCU04A04), and the Joint Usage/Research Center PRIUS (Ehime University, Japan) and Chinese Academy of Sciences (Grant No. 2017-BEPC-PT-000568).

  8. Se substitution and micro-nano-scale porosity enhancing thermoelectric Cu2Te

    NASA Astrophysics Data System (ADS)

    Shi, Xiaoman; Wang, Guoyu; Wang, Ruifeng; Zhou, Xiaoyuan; Xu, Jingtao; Tang, Jun; Ang, Ran

    2018-04-01

    Not Available Project supported by the National Natural Science Foundation of China (Grant Nos. 51771126 and 11774247), the Youth Foundation of Science and Technology Department of Sichuan Province, China (Grant No. 2016JQ0051), Sichuan University Outstanding Young Scholars Research Funding (Grant No. 2015SCU04A20), the World First-Class University Construction Funding, and the Fundamental and Frontier Research Project in Chongqing (Grant No. CSTC2015JCYJBX0026).

  9. TCAD Analysis of Heating and Maximum Current Density in Carbon Nanofiber Interconnects

    DTIC Science & Technology

    2011-09-01

    a metallic MWCNT interconnect. From [20]. ....20  Figure 11.  Simple equivalent circuit model of a metallic MWCNT interconnect. From [20...Carbon Nanotube MWCNT Multi-Walled Carbon Nanotube SCU Santa Clara University Si Silicon SiO2 Silicon Dioxide SiC Silicon Carbide Au Gold...proven, multi-walled carbon nanotube ( MWCNT ) [2]. He later discovered single-walled carbon nanotubes (SWCNT) in 1993 [13]. Since Iijima’s discovery

  10. Adaptive Machine Vision

    DTIC Science & Technology

    1992-11-03

    by the Neocognitron of Fukushima . DD ,JAN1, 1473 EON OF INO,,S OBSO.ETC Unclassified SCU0RITY CLASSIrICATION OF THIS PAGE (If%*n Paee F-e*et,’ I . 1.0...neural network developed by Fukushima and his colleagues (K. Fukushima , "Neocognitron: A self-organizing neural network model for a mechanism of...network architecture is the Neocognitron of Fukushima , we originally copied the feature detectors used in some of Fukushima’s papers for El/November 3

  11. Moscow’s Lessons from the 1982 Lebanon Air War

    DTIC Science & Technology

    1984-09-01

    or else failed to comprehend the tactical lessons suggested by Israeli combat perfbrmance. \\• O UL~Y~ aSCU @ hS~G1~ t,? - IT I , PREFACE The Rand...results of the Lebanese wnr anrd drawi- ag appropriate technical conclusions. They, like ourselves, are awarv~ th.-at thle AlM.VL was a star performer (not...it should be required." Air Power in the Nuclear Age (Chicago: University of Illinois Press, 1983). p 176. 12Maj. Gen. Jasper A. Welch, Jr., USAF

  12. Piercing the Fog: Intelligence and Army Air Forces Operations in World War 2

    DTIC Science & Technology

    1996-01-01

    prewar air warfare thinking was the ACTS at Maxwell Field. Most of the AAF’s World War I1 combat leaders spent one or more assignments at ACTS, and...Scanlon, Air Corps, spent most of the 1930s in London. His personal diaries were replete with an active social life, and his dispatches revealed...these periods, some SSOs spent up to nine hours daily traveling between headquarters and the SCU. Not surprisingly, service during these periods

  13. Band engineering and precipitation enhance thermoelectric performance of SnTe with Zn-doping

    NASA Astrophysics Data System (ADS)

    Chen, Zhiyu; Wang, Ruifeng; Wang, Guoyu; Zhou, Xiaoyuan; Wang, Zhengshang; Yin, Cong; Hu, Qing; Zhou, Binqiang; Tang, Jun; Ang, Ran

    2018-04-01

    Not Available Project supported by the National Natural Science Foundation of China (Grant No. 51771126), the Youth Foundation of Science & Technology Department of Sichuan Province, China (Grant No. 2016JQ0051), the Sichuan University Talent Introduction Research Funding (Grand No. YJ201537), the Sichuan University Outstanding Young Scholars Research Funding (Grant No. 2015SCU04A20), the World First-Class University Construction Funding, and the Fundamental and Frontier Research in Chongqing (Grant No. CSTC2015JCYJBX0026).

  14. Oligo-m-phenyleneoxalamide copper(II) mesocates as electro-switchable ferromagnetic metal-organic wires.

    PubMed

    Pardo, Emilio; Ferrando-Soria, Jesús; Dul, Marie-Claire; Lescouëzec, Rodrigue; Journaux, Yves; Ruiz-García, Rafael; Cano, Joan; Julve, Miguel; Lloret, Francesc; Cañadillas-Delgado, Laura; Pasán, Jorge; Ruiz-Pérez, Catalina

    2010-11-15

    Double-stranded copper(II) string complexes of varying nuclearity, from di- to tetranuclear species, have been prepared by the Cu(II)-mediated self-assembly of a novel family of linear homo- and heteropolytopic ligands that contain two outer oxamato and either zero (1 b), one (2 b), or two (3 b) inner oxamidato donor groups separated by rigid 2-methyl-1,3-phenylene spacers. The X-ray crystal structures of these Cu(II) (n) complexes (n=2 (1 d), 3 (2 d), and 4 (3 d)) show a linear array of metal atoms with an overall twisted coordination geometry for both the outer CuN(2)O(2) and inner CuN(4) chromophores. Two such nonplanar all-syn bridging ligands 1 b-3 b in an anti arrangement clamp around the metal centers with alternating M and P helical chiralities to afford an overall double meso-helicate-type architecture for 1 d-3 d. Variable-temperature (2.0-300 K) magnetic susceptibility and variable-field (0-5.0 T) magnetization measurements for 1 d-3 d show the occurrence of S=nS(Cu) (n=2-4) high-spin ground states that arise from the moderate ferromagnetic coupling between the unpaired electrons of the linearly disposed Cu(II) ions (S(Cu)=1/2) through the two anti m-phenylenediamidate-type bridges (J values in the range of +15.0 to 16.8 cm(-1)). Density functional theory (DFT) calculations for 1 d-3 d evidence a sign alternation of the spin density in the meta-substituted phenylene spacers in agreement with a spin polarization exchange mechanism along the linear metal array with overall intermetallic distances between terminal metal centers in the range of 0.7-2.2 nm. Cyclic voltammetry (CV) and rotating-disk electrode (RDE) electrochemical measurements for 1 d-3 d show several reversible or quasireversible one- or two-electron steps that involve the consecutive metal-centered oxidation of the inner and outer Cu(II) ions (S(Cu)=1/2) to diamagnetic Cu(III) ones (S(Cu)=0) at relatively low formal potentials (E values in the range of +0.14 to 0.25 V and of +0.43 to 0.67 V vs. SCE, respectively). Further developments may be envisaged for this family of oligo-m-phenyleneoxalamide copper(II) double mesocates as electroswitchable ferromagnetic 'metal-organic wires' (MOWs) on the basis of their unique ferromagnetic and multicenter redox behaviors.

  15. Improving Air Force Depot Programming by Linking Resources to Capabilities

    DTIC Science & Technology

    2012-01-01

    thank Rick Grisenthwaite at Warner Robins Air Logistics Center, Jamie Jeter at Okla- homa City Air Logistics Center, and Glen Brown at Ogden Air...consistency, we use the term block cycle instead of SCU in our F-16 discussions. 4 8 Im p ro vin g A ir Fo rce D ep o t Pro g ram m in g b y Lin kin...Requirements RAND TR905-B.8 Figure B.9 Depot Purchased Equipment Maintenance Model Output: Projected Aircraft Availability RAND TR905-B.9 A ir cr af t av

  16. Final report of PVM-6 and PVM-7 Weather Documentation, AFCRL/Minuteman Report Number 6

    DTIC Science & Technology

    1975-09-11

    Research Laboratories, Hanscon AFB, MA 01731. USAFGL ltr, 1 Aug 1983 TH!3 R~PORT HAS BEEN DELIMI~ED AND CLtARED FOR PUBLIC REL~5E UNDER DOP DiRECTIVE...5200.20 AND NO RESTniCTIONS ARE IMPDSED UPON r rs usE P.ND n 1 scu1sURI:. DISTRIBUTION STATE~ENT A APPROVED FQR PUBLIC RELEASE; DISTRIBUTION...NO AFCRL -TR-75 -04817^ F C ^ I - 1 ^T" 1 . » " 3^ 3 / *■ TlTUSfltf fidUtUlt- JINAL REPORT OFPyM-6 AND PVM-7 WEATHER DOCUMENTATION^ | AFCRl

  17. Exploring the prevalence and variance of cognitive impairment, pain, neuropsychiatric symptoms and ADL dependency among persons living in nursing homes; a cross-sectional study.

    PubMed

    Björk, Sabine; Juthberg, Christina; Lindkvist, Marie; Wimo, Anders; Sandman, Per-Olof; Winblad, Bengt; Edvardsson, David

    2016-08-22

    Earlier studies in nursing homes show a high prevalence of cognitive impairment, dependency in activities of daily living (ADL), pain, and neuropsychiatric symptoms among residents. The aim of this study was to explore the prevalence of the above among residents in a nationally representative sample of Swedish nursing homes, and to investigate whether pain and neuropsychiatric symptoms differ in relation to gender, cognitive function, ADL-capacity, type of nursing-home unit and length of stay. Cross-sectional data from 188 randomly selected nursing homes were collected. A total of 4831 residents were assessed for cognitive and ADL function, pain and neuropsychiatric symptoms. Data were analysed using descriptive statistics and the chi-square test. The results show the following: the prevalence of cognitive impairment was 67 %, 56 % of residents were ADL-dependent, 48 % exhibited pain and 92 % exhibited neuropsychiatric symptoms. The prevalence of pain did not differ significantly between male and female residents, but pain was more prevalent among cognitively impaired and ADL-dependent residents. Pain prevalence was not significantly different between residents in special care units for people with dementia (SCU) and general units, or between shorter-and longer-stay residents. Furthermore, the prevalence of neuropsychiatric symptoms did not differ significantly between male and female residents, between ADL capacities or in relation to length of stay. However, residents with cognitive impairment and residents in SCUs had a significantly higher prevalence of neuropsychiatric symptoms than residents without cognitive impairment and residents in general units. The prevalence rates ascertained in this study could contribute to a greater understanding of the needs of nursing-home residents, and may provide nursing home staff and managers with trustworthy assessment scales and benchmark values for further quality assessment purposes, clinical development work and initiating future nursing assessments.

  18. Supercritical Water Mixture (SCWM) Experiment

    NASA Technical Reports Server (NTRS)

    Hicks, Michael C.; Hegde, Uday G.

    2012-01-01

    The subject presentation, entitled, Supercritical Water Mixture (SCWM) Experiment, was presented at the International Space Station (ISS) Increment 33/34 Science Symposium. This presentation provides an overview of an international collaboration between NASA and CNES to study the behavior of a dilute aqueous solution of Na2SO4 (5% w) at near-critical conditions. The Supercritical Water Mixture (SCWM) investigation, serves as important precursor work for subsequent Supercritical Water Oxidation (SCWO) experiments. The SCWM investigation will be performed in DECLICs High Temperature Insert (HTI) for the purpose of studying critical fluid phenomena at high temperatures and pressures. The HTI includes a completely sealed and integrated test cell (i.e., Sample Cell Unit SCU) that will contain approximately 0.3 ml of the aqueous test solution. During the sequence of tests, scheduled to be performed in FY13, temperatures and pressures will be elevated to critical conditions (i.e., Tc = 374C and Pc = 22 MPa) in order to observe salt precipitation, precipitate agglomeration and precipitate transport in the presence of a temperature gradient without the influences of gravitational forces. This presentation provides an overview of the motivation for this work, a description of the DECLIC HTI hardware, the proposed test sequences, and a brief discussion of the scientific research objectives.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hallenbeck, L.D.; Harpole, K.J.; Gerard, M.G.

    The work reported here covers Budget Phase I of the project. The principal tasks in Budget Phase I are the Reservoir Analysis and Characterization Task and the Advanced Technology Definition Task. Completion of these tasks have enabled an optimum carbon dioxide (CO{sub 2}) flood project to be designed and evaluated from an economic and risk analysis standpoint. Field implementation of the project has been recommended to the working interest owner of the South Cowden Unit (SCU) and approval has been obtained. The current project has focused on reducing initial investment cost by utilizing horizontal injection wells and concentrating the projectmore » in the best productivity area of the field. An innovative CO{sub 2} purchase agreement (no take or pay requirements, CO{sub 2} purchase price tied to West Texas Intermediate crude oil price) and gas recycle agreements (expensing cost as opposed to large capital investments for compression) were negotiated to further improve project economics. A detailed reservoir characterization study was completed by an integrated team of geoscientists and engineers. The study consisted of detailed core description, integration of log response to core descriptions, mapping of the major flow units, evaluation of porosity and permeability relationships, geostatistical analysis of permeability trends, and direct integration of reservoir performance with the geological interpretation. The study methodology fostered iterative bidirectional feedback between the reservoir characterization team and the reservoir engineering/simulation team to allow simultaneous refinement and convergence of the geological interpretation with the reservoir model. The fundamental conclusion from the study is that South Cowden exhibits favorable enhanced oil recovery characteristics, particularly reservoir quality and continuity.« less

  20. Alterations in antioxidant defense system of workers chronically exposed to arsenic, cadmium and mercury from coal flying ash.

    PubMed

    Zeneli, Lulzim; Sekovanić, Ankica; Ajvazi, Majlinda; Kurti, Leonard; Daci, Nexhat

    2016-02-01

    Humans are exposed to different stress factors that are responsible for over-production of reactive oxygen species. Exposure to heavy metals is one of these factors. The aim of the study was to analyze the effect of chronic exposure to heavy metals through coal flying ash on the efficiency of antioxidative defensive mechanisms, represented by the activity of superoxide dismutase, glutathione peroxidase and ascorbic acid. Nonessential elements such as arsenic and mercury levels showed a significant increase (p > 0.001) in the power plant workers rather than in the control subjects. There were no significant differences of blood cadmium between power plant workers and control subjects. We found a significant positive correlation (p < 0.05) between BAs/SZn (r = 0.211), BAs/BSe (r = 0.287), BCd/SCu (r = 0.32) and BHg/BSe (r = 0.263) in the plant workers. Red blood cell antioxidant enzymes and plasma ascorbic acid were significantly lower in power plants workers than in the control group (p < 0.002). We can conclude that levels of mercury, arsenic and cadmium in blood, despite their concentration within the reference values, significantly affect plasma ascorbic acid concentration, superoxide dismutase and glutathione peroxidase activity, which are able to increase the risk of oxidative stress.

  1. A simulation study to improve the efficiency of ZnO1-xSx/Cu2ZnSn (Sy, Se1-y)4 solar cells by composition-ratio control

    NASA Astrophysics Data System (ADS)

    Sharbati, S.; Norouzzadeh, E.; Mohammadi, S.

    2018-04-01

    This work investigates the impact of the conduction-band offset (CBO) and valence band offset (VBO) on the performance of Zn (O, S)/Cu2ZnSn (S, Se)4 solar cells by numerical simulations. The band gap alignment at the buffer-CZTS layer interface are controlled by the sulfur-to-oxygen and sulfur-to-selenium ratios. The simulation results show that the high sulfur content in the Zn (O, S) layer makes a big offset in the conduction band and high oxygen content in the in the Zn (O, S) layer eventuates in large valence band offset, that descends Cu2ZnSn (S, Se)4 solar cell performance. We established an initial device model based on an experimental device with world record efficiencies of 12.6%. This study shows that most suitable heterojunction for ZnO1-xSx/Cu2ZnSn (Sy, Se1-y)4 solar cells is when sulfur content ranging 19%-50% in the Zn (O, S) and 30%-50% in the CZTSSe. The efficiency of Cu2ZnSn (S, Se)4 solar cells will be achieved to 14.3%.

  2. Interactions of Nitrogen Source and Rate and Weed Removal Timing Relative to Nitrogen Content in Corn and Weeds and Corn Grain Yield.

    PubMed

    Knight, Alexandra M; Everman, Wesley J; Jordan, David L; Heiniger, Ronnie W; Smyth, T Jot

    2017-01-01

    Adequate fertility combined with effective weed management is important in maximizing corn ( Zea mays L.) grain yield. Corn uptake of nitrogen (N) is dependent upon many factors including weed species and density and the rate and formulation of applied N fertilizer. Understanding interactions among corn, applied N, and weeds is important in developing management strategies. Field studies were conducted in North Carolina to compare corn and weed responses to urea ammonium nitrate (UAN), sulfur-coated urea (SCU), and composted poultry litter (CPL) when a mixture of Palmer amaranth ( Amaranthus palmeri S. Wats.) and large crabgrass ( Digitaria sanguinalis L.) was removed with herbicides at heights of 8 or 16 cm. These respective removal timings corresponded with 22 and 28 days after corn planting or V2 and V3 stages of growth, respectively. Differences in N content in above-ground biomass of corn were noted early in the season due to weed interference but did not translate into differences in corn grain yield. Interactions of N source and N rate were noted for corn grain yield but these factors did not interact with timing of weed control. These results underscore that timely implementation of control tactics regardless of N fertility management is important to protect corn grain yield.

  3. Full Food Service Contract for Army Dining Facilities

    DTIC Science & Technology

    1982-01-01

    I LB - — —- COP’JE *">ältfO tlA INSTANT VA 0/ 1.** ." CN I» ’v — —. 1 »M 1 it IB 5r ».!•. 4<j l.?n I.Ti .6) • e...1 i f*»n*j MfDI»"* T#BTAC SA’lCF tO-| 1| AFAISEC MM AND NOODLES II-1TI AA«FD •’’TATTf S (Q-441 SCuA f»FA« H-T *MCf O...degree F preheated oven for about 15 minutes or until cheese is melted. 8 Beef Noodle Soup (Dehydrated) Prepare in accordance with directions

  4. Youngstown MAP, Ohio. Revised Uniform Summary of Surface Weather Observations (RUSSWO). Parts A-F.

    DTIC Science & Technology

    1982-05-10

    Air Weather Service ( MAC ) SCuOL2., IL 6222 R- UmmRm m "PJ M MOP Fr 4 JUN SURFACE WEATHER OSVAIWJ YOUNGSTOWN MAP OH MC #725250 N 41 16 W 080 40 ELD...percentage frequency of distribution tables OHIO YOUNGSTIOWN M "P, OHIO 20. and dew point temperatures and relative humidity); and (F) Pressure Summnary...p.ouIwuIis P i o m Qm 1 ---- .0 YN - :, 7 -AL CLIMATOLO’Y RA"CH 7 .I*.T 7C WEATHER CONDITIONS .ATH’p SEPVICE/mAC CNIIN -, JN,.S7 %N MAP OH 73-81 A U G

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casalbuoni, S., E-mail: sara.casalbuoni@kit.edu; Cecilia, A.; Gerstl, S.

    Superconducting undulators (SCUs) have the potential to reach higher brilliance and flux with respect to the state of the art permanent magnet insertion devices. ANKA is collaborating with the industrial partner Babcock Noell GmbH (BNG) to realize NbTi conduction cooled planar devices for low emittance light sources, and is developing the instrumentation to characterize the magnetic field properties and to measure the beam heat load to a cold bore needed for the cryogenic design of SCUs. We present here: the most recent results obtained within the ANKA-BNG collaboration, the progress achieved in the development of the instrumentation, and the inmore » house studies on the application of high temperature superconducting (HTS) tape to the SCU technology.« less

  6. Chromothripsis Detection and Characterization Using the CTLPScanner Web Server.

    PubMed

    Yang, Jian; Liu, Bo; Cai, Haoyang

    2018-01-01

    Accurate detection of chromothripsis event is important to study the mechanisms underlying this phenomenon. CTLPScanner ( http://cgma.scu.edu.cn/CTLPScanner/ ) is a web-based tool for identification and annotation of chromothripsis-like pattern (CTLP) in genomic array data. In this chapter, we illustrate the utility of CTLPScanner for screening chromosome pulverization regions and give interpretation of the results. The web interface offers a set of parameters and thresholds for customized screening. We also provide practical recommendations for effective chromothripsis detection. In addition to the user data processing module, CTLPScanner contains more than 50,000 preprocessed oncogenomic arrays, which allow users to explore the presence of chromothripsis signatures from public data resources.

  7. Cerebrospinal fluid rhinorrhea: An institutional perspective from Pakistan.

    PubMed

    Tahir, Muhammad Zubair; Khan, Muhammad Babar; Bashir, Muhammad Umair; Akhtar, Shabbir; Bari, Ehsan

    2011-01-01

    The management of cerebrospinal fluid (CSF) rhinorrhea has evolved over the last two decades. We present here a review of our 11-year data on CSF rhinorrhea and its management at a tertiary care hospital in a developing country, with particular reference to the diagnosis, surgical management and outcome of the disease. The medical charts of all patients with a diagnosis of CSF rhinorrhea over an 11-year period were reviewed. The etiology of CSF rhinorrhea was classified into three categories: spontaneous, iatrogenic and traumatic. All the patients were divided into three categories based on the type of management as conservative, intracranial and transnasal endoscopic groups. A total of 43 patients fulfilled our inclusion criteria and were included in the final analysis. Eleven of the 43 patients were managed conservatively, while 22 underwent intracranial repairs; 10 patients had transnasal endoscopic repairs. The primary success rate for the transnasal approach was 70% compared to 86% for the intracranial repair. Blood loss, special care unit (SCU) stay and total cost were found to be significantly less in the transnasal endoscopic group. Computed tomography (CT) cisternography was found to have the highest sensitivity and specificity. Further, no postoperative complications were found in the transnasal endoscopic group, while five patients from the intracranial group developed various complications. We conclude that the transnasal endoscopic approach has comparable success rates with the intracranial approach and significantly lower morbidity.

  8. Nanoscale patterning of a self-assembled monolayer by modification of the molecule-substrate bond.

    PubMed

    Shen, Cai; Buck, Manfred

    2014-01-01

    The intercalation of Cu at the interface of a self-assembled monolayer (SAM) and a Au(111)/mica substrate by underpotential deposition (UPD) is studied as a means of high resolution patterning. A SAM of 2-(4'-methylbiphenyl-4-yl)ethanethiol (BP2) prepared in a structural phase that renders the Au substrate completely passive against Cu-UPD, is patterned by modification with the tip of a scanning tunneling microscope. The tip-induced defects act as nucleation sites for Cu-UPD. The lateral diffusion of the metal at the SAM-substrate interface and, thus, the pattern dimensions are controlled by the deposition time. Patterning down to the sub-20 nm range is demonstrated. The difference in strength between the S-Au and S-Cu bond is harnessed to develop the latent Cu-UPD image into a patterned binary SAM. Demonstrated by the exchange of BP2 by adamantanethiol (AdSH) this is accomplished by a sequence of reductive desorption of BP2 in Cu free areas followed by adsorption of AdSH. The appearance of Au adatom islands upon the thiol exchange suggests that the interfacial structures of BP2 and AdSH SAMs are different.

  9. Interactions of Nitrogen Source and Rate and Weed Removal Timing Relative to Nitrogen Content in Corn and Weeds and Corn Grain Yield

    PubMed Central

    Knight, Alexandra M.; Heiniger, Ronnie W.; Smyth, T. Jot

    2017-01-01

    Adequate fertility combined with effective weed management is important in maximizing corn (Zea mays L.) grain yield. Corn uptake of nitrogen (N) is dependent upon many factors including weed species and density and the rate and formulation of applied N fertilizer. Understanding interactions among corn, applied N, and weeds is important in developing management strategies. Field studies were conducted in North Carolina to compare corn and weed responses to urea ammonium nitrate (UAN), sulfur-coated urea (SCU), and composted poultry litter (CPL) when a mixture of Palmer amaranth (Amaranthus palmeri S. Wats.) and large crabgrass (Digitaria sanguinalis L.) was removed with herbicides at heights of 8 or 16 cm. These respective removal timings corresponded with 22 and 28 days after corn planting or V2 and V3 stages of growth, respectively. Differences in N content in above-ground biomass of corn were noted early in the season due to weed interference but did not translate into differences in corn grain yield. Interactions of N source and N rate were noted for corn grain yield but these factors did not interact with timing of weed control. These results underscore that timely implementation of control tactics regardless of N fertility management is important to protect corn grain yield. PMID:28487878

  10. Influence of certain forces on evolution of synonymous codon usage bias in certain species of three basal orders of aquatic insects.

    PubMed

    Selva Kumar, C; Nair, Rahul R; Sivaramakrishnan, K G; Ganesh, D; Janarthanan, S; Arunachalam, M; Sivaruban, T

    2012-12-01

    Forces that influence the evolution of synonymous codon usage bias are analyzed in six species of three basal orders of aquatic insects. The rationale behind choosing six species of aquatic insects (three from Ephemeroptera, one from Plecoptera, and two from Odonata) for the present analysis is based on phylogenetic position at the basal clades of the Order Insecta facilitating the understanding of the evolution of codon bias and of factors shaping codon usage patterns in primitive clades of insect lineages and their subtle differences in some of their ecological and environmental requirements in terms of habitat-microhabitat requirements, altitudinal preferences, temperature tolerance ranges, and consequent responses to climate change impacts. The present analysis focuses on open reading frames of the 13 protein-coding genes in the mitochondrial genome of six carefully chosen insect species to get a comprehensive picture of the evolutionary intricacies of codon bias. In all the six species, A and T contents are observed to be significantly higher than G and C, and are used roughly equally. Since transcription hypothesis on codon usage demands A richness and T poorness, it is quite likely that mutation pressure may be the key factor associated with synonymous codon usage (SCU) variations in these species because the mutation hypothesis predicts AT richness and GC poorness in the mitochondrial DNA. Thus, AT-biased mutation pressure seems to be an important factor in framing the SCU variation in all the selected species of aquatic insects, which in turn explains the predominance of A and T ending codons in these species. This study does not find any association between microhabitats and codon usage variations in the mitochondria of selected aquatic insects. However, this study has identified major forces, such as compositional constraints and mutation pressure, which shape patterns of codon usage in mitochondrial genes in the primitive clades of insect lineages.

  11. pySCu: A new python code for analyzing remagnetizations directions by means of small circle utilities

    NASA Astrophysics Data System (ADS)

    Calvín, Pablo; Villalaín, Juan J.; Casas-Sainz, Antonio M.; Tauxe, Lisa; Torres-López, Sara

    2017-12-01

    The Small Circle (SC) methods are founded upon two main starting hypotheses: (i) the analyzed sites were remagnetized contemporarily, acquiring the same paleomagnetic direction. (ii) The deviation of the acquired paleomagnetic signal from its original direction is only due to tilting around the bedding strike and therefore the remagnetization direction must be located on a small circle (SC) whose axis is the strike of bedding and contains the in situ paleomagnetic direction. Therefore, if we analyze several sites (with different bedding strikes) their SCs will intersect in the remagnetization direction. The SC methods have two applications: (1) the Small Circle Intersection (SCI) method is capable of providing adequate approximations to the expected paleomagnetic direction when dealing with synfolding remagnetizations. By comparing the SCI direction with that predicted from an apparent polar wander path, the (re)magnetization can be dated. (2) Once the remagnetization direction is known, the attitude of the beds (at each site) can be restored to the moment of the acquisition of the remagnetization, showing a palinspastic reconstructuion of the structure. Some caveats are necessary under more complex tectonic scenarios, in which SC-based methods can lead to erroneous interpretations. However, the graphical output of the methods tries to avoid 'black-box' effects and can minimize misleading interpretations or even help, for example, to identify local or regional vertical axis rotations. In any case, the methods must be used with caution and always considering the knowledge of the tectonic frame. In this paper, some utilities for SCs analysis are automatized by means of a new Python code and a new technique for defining the uncertainty of the solution is proposed. With pySCu the SCs methods can be easily and quickly applied, obtaining firstly a set of text files containing all calculated information and subsequently generating a graphical output on the fly.

  12. Development of Navy Methodologies for Relating Logistics Resources to Materiel Readiness.

    DTIC Science & Technology

    1984-04-08

    Delete Page: Not Cleared For Open Publicat- ion. The page was put in document by error per Mr. James Willoughby, OASD/MR L .L .fI TABLE OF CONTENTS Page...cu cu r r’- Cuj Scu cu CU C Cu 1 cu- Cui CL - Cu U a cu z.n I - u cuI ir* 00 D 0 coh4~ I Cu I .~ u 0 0.- 1 - j . L j U I ~ M =- 12* S L":~ MI. I L...9561 C8IITIII C C PRINT III GREATEST THIEVES C C SNAP FILES TO USE 10 INITIAL. INVERIORY FOR MEX YEAR’S PROCESSING 91 IF(E1IFLC)GO TO9 RENIN 11 RuMin

  13. Review of computational fluid dynamics (CFD) researches on nano fluid flow through micro channel

    NASA Astrophysics Data System (ADS)

    Dewangan, Satish Kumar

    2018-05-01

    Nanofluid is becoming a promising heat transfer fluids due to its improved thermo-physical properties and heat transfer performance. Micro channel heat transfer has potential application in the cooling high power density microchips in CPU system, micro power systems and many such miniature thermal systems which need advanced cooling capacity. Use of nanofluids enhances the effectiveness of t=scu systems. Computational Fluid Dynamics (CFD) is a very powerful tool in computational analysis of the various physical processes. It application to the situations of flow and heat transfer analysis of the nano fluids is catching up very fast. Present research paper gives a brief account of the methodology of the CFD and also summarizes its application on nano fluid and heat transfer for microchannel cases.

  14. Molecular-specific urokinase antibodies

    NASA Technical Reports Server (NTRS)

    Atassi, M. Zouhair (Inventor); Morrison, Dennis R. (Inventor)

    2009-01-01

    Antibodies have been developed against the different molecular forms of urokinase using synthetic peptides as immunogens. The peptides were synthesized specifically to represent those regions of the urokinase molecules which are exposed in the three-dimensional configuration of the molecule and are uniquely homologous to urokinase. Antibodies are directed against the lysine 158-isoleucine 159 peptide bond which is cleaved during activation from the single-chain (ScuPA) form to the bioactive double chain (54 KDa and 33 KDa) forms of urokinase and against the lysine 135 lysine 136 bond that is cleaved in the process of removing the alpha-chain from the 54 KDa form to produce the 33 KDa form of urokinase. These antibodies enable the direct measurement of the different molecular forms of urokinase from small samples of conditioned medium harvested from cell cultures.

  15. Tetranuclear cluster-based Pb(II)-MOF: Synthesis, crystal structure and luminescence sensing for CS2

    NASA Astrophysics Data System (ADS)

    Dong, Yanli

    2018-05-01

    A new Pb(II) coordination polymer, namely [Pb2(bptc)(DMA)]n (1, H4bptc = biphenyl-3,3‧,5,5‧-tetracarboxylic acid, DMA = N, N‧- dimethylacetamide), has been synthesized by the combination of H4bptc with Pb(NO3)2 under solvothermal conditions. Single crystal X-ray diffraction analysis revealed that compound 1 features a 3D framework based on tetranuclear [Pb4(COO)6] subunits, and topological analysis revealed that compound represents a binodal (4, 8)-connected scu-type topological network with the point symbol of {416,612}{44,62}2. Luminescence studies indicated that 1 and 1' (1‧ represents the desolvated samples) showed intense yellow emissions. Significantly, 1‧ exhibited sensitive luminescence sensing for CS2 solvent molecules at a low concentration.

  16. VMD-SS: A graphical user interface plug-in to calculate the protein secondary structure in VMD program.

    PubMed

    Yahyavi, Masoumeh; Falsafi-Zadeh, Sajad; Karimi, Zahra; Kalatarian, Giti; Galehdari, Hamid

    2014-01-01

    The investigation on the types of secondary structure (SS) of a protein is important. The evolution of secondary structures during molecular dynamics simulations is a useful parameter to analyze protein structures. Therefore, it is of interest to describe VMD-SS (a software program) for the identification of secondary structure elements and its trajectories during simulation for known structures available at the Protein Data Bank (PDB). The program helps to calculate (1) percentage SS, (2) SS occurrence in each residue, (3) percentage SS during simulation, and (4) percentage residues in all SS types during simulation. The VMD-SS plug-in was designed using TCL script and stride to calculate secondary structure features. The database is available for free at http://science.scu.ac.ir/HomePage.aspx?TabID=13755.

  17. Ammonia volatilization from a Chinese cabbage field under different nitrogen treatments in the Taihu Lake Basin, China.

    PubMed

    Shan, Linan; He, Yunfeng; Chen, Jie; Huang, Qian; Wang, Hongcai

    2015-12-01

    Ammonia (NH3) volatilization is a major pathway of nitrogen (N) loss from soil-crop systems. As vegetable cultivation is one of the most important agricultural land uses worldwide, a deeper understanding of NH3 volatilization is necessary in vegetable production systems. We therefore conducted a 3-year (2010-2012) field experiment to characterize NH3 volatilization and evaluate the effect of different N fertilizer treatments on this process during the growth period of Chinese cabbage. Ammonia volatilization rate, rainfall, soil water content, pH, and soil NH4(+) were measured during the growth period. The results showed that NH3 volatilization was significantly and positively correlated to topsoil pH and NH4(+) concentration. Climate factors and fertilization method also significantly affected NH3 volatilization. Specifically, organic fertilizer (OF) increased NH3 volatilization by 11.77%-18.46%, compared to conventional fertilizer (CF, urea), while organic-inorganic compound fertilizer (OIF) reduced NH3 volatilization by 8.82%-12.67% compared to CF. Furthermore, slow-release fertilizers had significantly positive effects on controlling NH3 volatilization, with a 60.73%-68.80% reduction for sulfur-coated urea (SCU), a 71.85%-78.97% reduction for biological Carbon Power® urea (BCU), and a 77.66%-83.12% reduction for bulk-blend controlled-release fertilizer (BBCRF) relative to CF. This study provides much needed baseline information, which will help in fertilizer choice and management practices to reduce NH3 volatilization and encourage the development of new strategies for vegetable planting. Copyright © 2015. Published by Elsevier B.V.

  18. [Argentine guidelines for urticaria and angioedema].

    PubMed

    Máspero, Jorge; Cabrera, Hugo; Ardusso, Ledit; De Gennaro, Mónica; Fernández Bussy, Ramón; Galimany, José; Galimberti, Daniel; Label, Marcelo; La Forgia, Marta; Medina, Iris; Neffen, Hugo; Troielli, Patricia

    2014-01-01

    This interdisciplinary paper summarizes the news in the diagnosis and treatment of chronic urticaria (CU), and provides concepts, definitions and evidence-based suggestions for its management. Urticaria occurs in at least 20% of the population at some point in their lives. Acute urticaria (less than 6 weeks' duration), differs from CU in its etiology, but the onset of this disease is always acute. CU may occur as spontaneous (SCU) or induced (ICU). The diagnosis is simple, although a careful evaluation is necessary for differential diagnosis. ICU's diagnosis is mainly clinical, even if provocation tests can be useful. Supplementary studies should be limited and based on the clinical suspicion. Treatment may be divided into three approaches: avoidance, elimination or treatment of the cause, and pharmacological treatment. Recently treatment has been modified with the use of second-generation antihistamines as first-line and increased doses of nonsedating H1 antihistamines, up to 4 times, as second line. Antihistamines are essential to treat CU; however, 40% of patients do not achieve good control despite increased doses and require additional treatment. The most recent evidence indicates a group of drugs to be used as third line in these cases, to improve quality of life and to limit toxicity from frequent or chronic use of systemic steroids. Only 3 drugs are recommended as third line: omalizumab, cyclosporin A or anti-leukotrienes.

  19. National Dam Inspection Program. Bear Gulch Pond Dam (NY 01089), Mohawk River Basin, Town of Summit, Schoharie County, New York. Phase I Inspection Report,

    DTIC Science & Technology

    1981-08-18

    experienced minor rockfalls . c. Appurtenant Structures 1) Intake Structure and Gate House The intake structure is reportedly a vertical 3-foot-diameter...EDWIN COVA t iRONC_ V. t>U - CF 4I: t I- AL-L. ?PFfONM’j1.L WSMT o W 5//8 wsrc-r-iwj ONLY,’ VoP e’_L4K leN ’.-/2 /S C % V41 G: (oCjf -- K /A4A’Ar Gi QF...kTM WV= SCALE S e o. AIS M 4_ --- I svWlk W/ -. JET SCU~,p, cLz’j Gi - t- ’I L j~ F I I ~O$ de.~P,~T T ~v ~tTM’,MTiQ F---- ~~flLJJ-m𔃾 IlET TL -7e IT

  20. Copper(II) complexes of tridentate N, N, N', N″, N″-pentamethyldiethylenetriamine: Superoxide dismutase and inhibitory activity against bacteria and fungi

    NASA Astrophysics Data System (ADS)

    Patel, R. N.; Singh, Nripendra; Gundla, V. L. N.; Chauhan, U. K.

    2007-03-01

    A series of ternary copper(II) complexes containing same coordination sphere but difference in the counter ions, viz., [Cu(PMDT)(OAc)]PF 6(1); [Cu(PMDT)(OAc)]ClO 4(2); [Cu(PMDT)(OAc)]BF 4(3) and [Cu(PMDT)(OAc)]BPh 4(4) where PMDT = N, N, N', N″, N″-pentamethyldiethylenetriamine, OAc = Acetate ion were synthesized and characterized by means of spectroscopic, magnetic and cyclic voltammetric measurements. In frozen solution e.p.r. spectra, an interesting relation g|| > g⊥ has been observed which is a typical of the axially symmetric d 9 Cu II ( SCu = 1/2) having an unpaired electron in a d orbital. Single crystal X-ray analysis of (1) has revealed the presence of distorted square planar geometry. The influence of the counter ion on the complexes has been examined by performing some biological experiments like superoxide dismutase and anti-microbial activity.

  1. On the nature of the Cu-rich aggregates in brain astrocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Brendan; Robison, Gregory; Osborn, Jenna

    Fulfilling a bevy of biological roles, copper is an essential metal for healthy brain function. Cu dyshomeostasis has been demonstrated to be involved in some neurological conditions including Menkes and Alzheimer’s diseases. We have previously reported localized Cu-rich aggregates in astrocytes of the subventricular zone (SVZ) in rodent brains with Cu concentrations in the hundreds of millimolar. Metallothionein, a cysteine-rich protein critical to metal homeostasis and known to participate in a variety of neuroprotective and neuroregenerative processes, was proposed as a binding protein. Here, we present an analysis of metallothionein(1,2) knockout (MTKO) mice and age-matched controls using X-ray fluorescence microscopy.more » In large structures such as the corpus callosum, cortex, and striatum, there is no significant difference in Cu, Fe, or Zn concentrations in MTKO mice compared to age-matched controls. In the astrocyte-rich subventricular zone where Cu-rich aggregates reside, approximately 1/3 as many Cu-rich aggregates persist in MTKO mice resulting in a decrease in periventricular Cu concentration. Aggregates in both wild-type and MTKO mice show XANES spectra characteristic of CuxSy multimetallic clusters and have similar [S]/[Cu] ratios. Consistent with assignment as a CuxSy multimetallic cluster, the astrocyte-rich SVZ of both MTKO and wild-type mice exhibit autofluorescent bodies, though MTKO mice exhibit fewer. Furthermore, XRF imaging of Au-labeled lysosomes and ubiquitin demonstrates a lack of co-localization with Cu-rich aggregates suggesting they are not involved in a degradation pathway. Overall, these data suggest that Cu in aggregates is bound by either metallothionein-3 or a yet unknown protein similar to metallothionein.« less

  2. Bioinorganic modeling chemistry of carbon monoxide dehydrogenases: description of model complexes, current status and possible future scopes.

    PubMed

    Majumdar, Amit

    2014-08-28

    Carbon monoxide dehydrogenases (CODHs) use CO as their sole source of carbon and energy and are found in both aerobic and anaerobic carboxidotrophic bacteria. Reversible transformation of CO to CO2 is catalyzed by a bimetallic [Mo-(μ2-S)-Cu] system in aerobic and by a highly asymmetric [Ni-Fe-S] cluster in anaerobic CODH active sites. The CODH activity in the microorganisms effects the removal of almost 10(8) tons of CO annually from the lower atmosphere and earth and thus help to maintain a sub-toxic concentration of CO. Despite an appreciable amount of work, the mechanism of CODH activity is not clearly understood yet. Moreover, biomimetic chemistry directed towards the active sites of CODHs faces several synthetic challenges. The synthetic problems associated with the modeling chemistry and strategies adopted to overcome those problems are discussed along with their limitations. A critical analysis of the exciting results delineating the present status of CODH modeling chemistry and its future prospects are presented.

  3. Implementing the recommended curriculum in biochemistry and molecular biology at a regional comprehensive university through a biology/chemistry double major: The minnesota state university moorhead experience*.

    PubMed

    Wallert, Mark; Brisch, Ellen; Chastain, Chris; Malott, Michelle; Provost, Joseph

    2004-05-01

    Minnesota State University Moorhead (MSUM) is a regional comprehensive university that is part of the Minnesota State Colleges and Universities (MnSCU) system. The current student population consists of ∼7,600 full- and part-time students who are enrolled in one of 135 majors that lead to baccalaureate degrees. MSUM is committed to excellence in science teaching and research for undergraduates. It is an institutional member of the Council on Undergraduate Research and has three faculty members participating in Project Kaleidoscope (PKAL) Faculty for the 21st Century. Fourteen years ago, MSUM renewed its effort to have faculty participate in active research. All science faculty members hired since that time have been required to establish research programs. The primary purpose for the faculty engaging in ongoing research projects is to involve undergraduates in a meaningful research experience, thus training these students to become scientists. Copyright © 2004 International Union of Biochemistry and Molecular Biology, Inc.

  4. Spin filter perfusion system for high density cell culture: production of recombinant urinary type plasminogen activator in CHO cells.

    PubMed

    Avgerinos, G C; Drapeau, D; Socolow, J S; Mao, J I; Hsiao, K; Broeze, R J

    1990-01-01

    We have used a 20 liter stirred tank fermentor, equipped with a 127 mesh ethylene-tetrafluoroethylene rotating screen for cell recycle, for the continuous production of recombinant single chain urokinase-type plasminogen activator (rscu-PA) from Chinese hamster ovary (CHO) cells. Viable cell densities between 60 and 74 million per ml were maintained at medium perfusion rates of 3.0 to 4.0 fermentor volumes per day. Cells were retained by the 120 micron nominal opening filter through the formation of "clumped" cell aggregates of 200 to 600 microns in size, which did not foul the filter. In 31 days of culture, a total of 51 grams of rscu-PA were produced in 1,000 liters of medium. The rscu-PA produced over the course of this continuous culture was purified and characterized both in vitro and in vivo and shown to be comparable to natural scu-PA produced from the transformed human kidney cell line, TCL-598.

  5. Highly efficient SO₂ absorption and its subsequent utilization by weak base/polyethylene glycol binary system.

    PubMed

    Yang, Zhen-Zhen; He, Liang-Nian; Zhao, Ya-Nan; Yu, Bing

    2013-02-05

    A binary system consisting of polyethylene glycol (PEG, proton donor)/PEG-functionalized base with suitable basicity was developed for efficient gas desulfurization (GDS) and can be regarded as an alternative approach to circumvent the energy penalty problem in the GDS process. High capacity for SO(2) capture up to 4.88 mol of SO(2)/mol of base was achieved even under low partial pressure of SO(2). Furthermore, SO(2) desorption runs smoothly under mild conditions (N(2), 25 °C) and no significant drop in SO(2) absorption was observed after five-successive absorption-desorption cycles. On the other hand, the absorbed SO(2) by PEG(150)MeIm/PEG(150), being considered as the activated form of SO(2), can be directly transformed into value-added chemicals under mild conditions, thus eliminating the energy penalty for SO(2) desorption and simultaneously realizing recycle of the absorbents. Thus, this SO(2) capture and utilization (SCU) process offers an alternative way for GDS and potentially enables the SO(2) conversion from flue gas to useful chemicals as a value-added process.

  6. Structural and magnetic characterization of three tetranuclear Cu(II) complexes with face-sharing-dicubane/double-open-cubane like core framework

    NASA Astrophysics Data System (ADS)

    Paul, Aparup; Bertolasi, Valerio; Figuerola, Albert; Manna, Subal Chandra

    2017-05-01

    Three novel tetranuclear copper(II) complexes namely [Cu4(L1)4]•2(dmf) (1), [Cu4(L1)4] (2) and [Cu4(L2)2(HL2)2(H2O)2]•2(ClO4)·6(H2O) (3) (H2L1, (E)-2-((1-hydroxybutan-2-ylimino)methyl)phenol; H2L2, (E)-2-((1-hydroxybutan-2-ylimino)methyl)-6-methoxyphenol)) were synthesized from the self-assembly of copper(II) perchlorate and the tridentate Schiff base ligands. The structural determination reveals that complex 1 crystallizes in the monoclinic system with space group C2/c, whereas both the complexes 2 and 3 crystallize in the triclinic system with space group P-1. Complexes 1 and 2 possess face-sharing dicubane core, on the other hand complex 3 has double open cubane core structure. The copper(II) ions in the cubane core are in distorted square planar geometries, and weak π…π and C-H…π interactions lead to formation of a 2D supramolecular architecture for complexes 1 and 2. At room temperature complexes 1, 2 and 3, exhibit fluorescence with a quantum yield (Φs) of 0.47, 0.49 and 0.38, respectively. Variable temperature magnetic susceptibility measurements in the range 2-300 K indicate an overall weak antiferromagnetic exchange coupling in all complexes. The PHI program was used to study their magnetic behaviour. In agreement with their face-sharing dicubane structure, a Hamiltonian of the type H =- J1(S1S2+S1S2'+S1'S2+S1'S2') - J2S1S1', where S1 = S1' = S2 = S2' = SCu =1/2, was used for studying complexes 1 and 2. Simulations performed suggest magnetic exchange constants with values close to J1 =-20 cm-1 and J2 =0 cm-1 for these complexes. On the other hand, the spin Hamiltonian H =- J1(S1S4+S2S3) - J2(S1S3+S2S4) - J3S1S2, where S1 = S2 = S3 = S4 = SCu =1/2, was used to study the magnetic behaviour of the double open cubane core of complex 3 and a good agreement between the experimental and simulated results was found by using the parameters g1 = g2 =2.20, g3 = g4 =2.18, J1 =-36 cm-1, J2 =-44 cm-1 and J3 =0 cm-1.

  7. Is it possible to encourage hope in non-advanced cancer patients? We must try.

    PubMed

    Ripamonti, C I; Miccinesi, G; Pessi, M A; Di Pede, P; Ferrari, M

    2016-03-01

    Data are lacking on the relationship between hope and other variables in non-advanced cancer patients. The study explored the relationship between hope, symptoms, needs, and spirituality/religiosity in patients treated in a supportive care unit (SCU). From September 2013 to March 2014, the consecutive patients who accepted to complete: (i) Needs Evaluation Questionnaire (NEQ), (ii) the Edmonton Symptom Assessment System (ESAS), (iii) Hope Herth Index (HHI), and (iv) the System of Belief Inventory (SBI) were enrolled. Moreover, clinical/demographic data were collected and the findings were analyzed. A total of 276 patients who completed the HHI questionnaire (participation rate 276/300 = 92%) were included; 131 reported HHI total score >37 (median value). The majority of patients had a Karnofsky performance status >80; 71% were on cancer therapies, and only 29 patients had metastases or relapse. Patients with higher HHI scores were less educated (P = 0.012), reported lower ESAS total score (15.4 versus 22.6, P < 0.001), and had less often been referred to a psychologist previously to the study (P = 0.002); patients with a higher HHI score also reported higher spirituality (P < 0.001). Some NEQ items resulted significantly associated with HHI score after adjustment for other variables: the need to have sincere clinicians (β = -2.7), better dialogue (β = -2.1), and more reassurance from the clinicians (β = -2.5); better attention (β = -4.4) and respect for intimacy (β = -3.3) from nurses; to speak with people who have the same illness experience (β = -2.5), to be more reassured by relatives (β = -3.3) and to feel less abandoned (β = -4.3). Higher SBI scores were independently associated with higher HHI scores (β = 1.7 for 10 points increase). In cancer patients, hope can be encouraged by clinicians through dialogue, sincerity, and reassurance, as well as assessing and considering the patients' needs (above all the psycho-emotional), symptoms, psychological frailty, and their spiritual/religious resources. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Reaction Mechanisms of Metals with Hydrogen Sulfide and Thiols in Model Wine. Part 1: Copper-Catalyzed Oxidation.

    PubMed

    Kreitman, Gal Y; Danilewicz, John C; Jeffery, David W; Elias, Ryan J

    2016-05-25

    Sulfidic off-odors as a result of hydrogen sulfide (H2S) and low-molecular-weight thiols are commonly encountered in wine production. These odors are usually removed by the process of Cu(II) fining, a process that remains poorly understood. The present study aims to elucidate the underlying mechanisms by which Cu(II) interacts with H2S and thiol compounds (RSH) under wine-like conditions. Copper complex formation was monitored along with H2S, thiol, oxygen, and acetaldehyde concentrations after the addition of Cu(II) (50 or 100 μM) to air-saturated model wine solutions containing H2S, cysteine, 6-sulfanylhexan-1-ol, or 3-sulfanylhexan-1-ol (300 μM each). The presence of H2S and thiols in excess to Cu(II) led to the rapid formation of ∼1.4:1 H2S/Cu and ∼2:1 thiol/Cu complexes, resulting in the oxidation of H2S and thiols and reduction of Cu(II) to Cu(I), which reacted with oxygen. H2S was observed to initially oxidize rather than form insoluble copper sulfide. The proposed reaction mechanisms provide insight into the extent to which H2S can be selectively removed in the presence of thiols in wine.

  9. Internally consistent database for sulfides and sulfosalts in the system Ag 2S-Cu 2S-ZnS-Sb 2S 3-As 2S 3

    NASA Astrophysics Data System (ADS)

    Sack, Richard O.

    2000-11-01

    An updated thermodynamic database for Ag 2S-Cu 2S-ZnS-Sb 2S 3-As 2S 3 sulfides and sulfosalts applicable to temperatures above 119°C is developed to calculate phase relations for polybasite-pearceite- and fahlore-bearing assemblages. It is based on pre-existing and new constraints on activity-composition, Ag-Cu and As-Sb partitioning, and other relations, and on experiments (200-300°C, evacuated silica tubes) conducted to define the stability of the polybasite-pearceite [(Ag 1- x,Cu x) 16(Sb 1- y,As y) 2S 11] + ZnS sphalerite assemblage with respect to assemblages containing (Ag,Cu) 2S sulfides coexisting with (Cu, Ag) 10Zn 2(Sb,As) 4S 13 fahlore sulfosalts. It was found that the thermodynamics of mixing of bcc- and hcp-(Ag,Cu) 2S solutions, which are fast-ion conductors, may be described by using site multiplicities of metals α Ag,Cu > 2 and temperature-dependent regular solution parameters. We obtained estimates for the Gibbs energies of formation for Ag 16Sb 2S 11 and Cu 16Sb 2S 11 polybasite endmembers from the simple sulfides (Ag 2S, Cu 2S, and Sb 2S 3) of -30.79 and -4.07 kJ/gfw at 200°C, and -32.04 and -0.59 kJ/gfw at 400°C, respectively, that are about one half kJ/gfw more positive and about 6 kJ/gfw more negative than those estimated by Harlov and Sack (1995b). The corresponding estimates for formation energies of Ag 10Zn 2Sb 4S 13 and Cu 10Zn 2Sb 4S 13 fahlores (-20.29 and -105.29 kJ/gfw at 200°C and -23.72 and -105.76 kJ/gfw at 400°C) are comparable to, and roughly 110 kJ/gfw more positive than, the corresponding estimates of Ebel and Sack (1994). We also determined that the Gibbs energies of the As-Sb exchange reactions: 1/4Ag 10Zn2Sb4S13+1/2Ag 16As2S11=1/2Ag 16Sb2S11+1/4Ag 10Zn2As4S13Sb-fahlorepearceitepolybasiteAs-fahlore and Ag3SbS3+1/2Ag 16As2S11=1/2Ag 16Sb2S11+Ag3AsS3pyrargyritepearceitepolybasiteproustite are, respectively, 8.75 and 0.40 kJ/gfw in the range 150-350°C, and these predictions are consistent with As-Sb partitioning relations observed in nature and produced in laboratory studies. Finally, we obtain estimates for the Gibbs energies of formation of Cu 10Fe 2Sb 4S 13 and Ag 10Fe 2Sb 4S 13 fahlores (-63.92 and +11.46 kJ/gfw at 200°C and -75.73 and -3.31 kJ/gfw at 400°C).

  10. Distributed and recoverable digital control system

    NASA Technical Reports Server (NTRS)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A real-time multi-tasking digital control system with rapid recovery capability is disclosed. The control system includes a plurality of computing units comprising a plurality of redundant processing units, with each of the processing units configured to generate one or more redundant control commands. One or more internal monitors are employed for detecting data errors in the control commands. One or more recovery triggers are provided for initiating rapid recovery of a processing unit if data errors are detected. The control system also includes a plurality of actuator control units each in operative communication with the computing units. The actuator control units are configured to initiate a rapid recovery if data errors are detected in one or more of the processing units. A plurality of smart actuators communicates with the actuator control units, and a plurality of redundant sensors communicates with the computing units.

  11. 28 CFR 541.50 - Release from a control unit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...

  12. 28 CFR 541.50 - Release from a control unit.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...

  13. 28 CFR 541.50 - Release from a control unit.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...

  14. 28 CFR 541.50 - Release from a control unit.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...

  15. 28 CFR 541.50 - Release from a control unit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...

  16. The instrument control unit of SPICA SAFARI: a macro-unit to host all the digital control functionalities of the spectrometer

    NASA Astrophysics Data System (ADS)

    Di Giorgio, Anna Maria; Biondi, David; Saggin, Bortolino; Shatalina, Irina; Viterbini, Maurizio; Giusi, Giovanni; Liu, Scige J.; Cerulli-Irelli, Paquale; Van Loon, Dennis; Cara, Christophe

    2012-09-01

    We present the preliminary design of the Instrument Control Unit (ICU) of the SpicA FAR infrared Instrument (SAFARI), an imaging Fourier Transform Spectrometer (FTS) designed to give continuous wavelength coverage in both photometric and spectroscopic modes from around 34 to 210 µm. Due to the stringent requirements in terms of mass and volume, the overall SAFARI warm electronics will be composed by only two main units: Detector Control Unit and ICU. ICU is therefore a macro-unit incorporating the four digital sub-units dedicated to the control of the overall instrument functionalities: the Cooler Control Unit, the Mechanism Control Unit, the Digital processing Unit and the Power Supply Unit. Both the mechanical solution adopted to host the four sub-units and the internal electrical architecture are presented as well as the adopted redundancy approach.

  17. Reactor vessel annealing system

    DOEpatents

    Miller, Phillip E.; Katz, Leonoard R.; Nath, Raymond J.; Blaushild, Ronald M.; Tatch, Michael D.; Kordalski, Frank J.; Wykstra, Donald T.; Kavalkovich, William M.

    1991-01-01

    A system for annealing a vessel (14) in situ by heating the vessel (14) to a defined temperature, composed of: an electrically operated heater assembly (10) insertable into the vessel (14) for heating the vessel (14) to the defined temperature; temperature monitoring components positioned relative to the heater assembly (10) for monitoring the temperature of the vessel (14); a controllable electric power supply unit (32-60) for supplying electric power required by the heater assembly (10); a control unit (80-86) for controlling the power supplied by the power supply unit (32-60); a first vehicle (2) containing the power supply unit (32-60); a second vehicle (4) containing the control unit (80-86); power conductors (18,22) connectable between the power supply unit (32-60) and the heater unit (10) for delivering the power supplied by the power supply unit (32-60) to the heater assembly (10); signal conductors (20,24) connectable between the temperature monitoring components and the control unit (80-86) for delivering temperature indicating signals from the temperature monitoring components to the control unit (80-86); and control conductors (8) connectable between the control unit (80-86) and the power supply unit (32-60) for delivering to the power supply unit (32-60) control signals for controlling the level of power supplied by the power supply unit (32-60) to the heater assembly (10).

  18. 28 CFR 541.49 - Review of control unit placement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Once every 30 days, the control unit team, comprised of the control unit manager and other members... required to attend the team meeting in order to be eligible for the previous month's stay in the control unit to be credited towards the projected duration of confinement in that unit. The unit team shall...

  19. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  20. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  1. Method and system for redundancy management of distributed and recoverable digital control system

    NASA Technical Reports Server (NTRS)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2012-01-01

    A method and system for redundancy management is provided for a distributed and recoverable digital control system. The method uses unique redundancy management techniques to achieve recovery and restoration of redundant elements to full operation in an asynchronous environment. The system includes a first computing unit comprising a pair of redundant computational lanes for generating redundant control commands. One or more internal monitors detect data errors in the control commands, and provide a recovery trigger to the first computing unit. A second redundant computing unit provides the same features as the first computing unit. A first actuator control unit is configured to provide blending and monitoring of the control commands from the first and second computing units, and to provide a recovery trigger to each of the first and second computing units. A second actuator control unit provides the same features as the first actuator control unit.

  2. Development, implementation, and evaluation of an integrated multidisciplinary Objective Structured Clinical Examination (OSCE) in primary health care settings within limited resources.

    PubMed

    Abdelaziz, Adel; Hany, Mohamed; Atwa, Hani; Talaat, Wagdy; Hosny, Somaya

    2016-01-01

    In ordinary circumstances, objective structured clinical examination (OSCE) is a resource-intensive assessment method. In case of developing and implementing multidisciplinary OSCE, there is no doubt that the cost will be greater. Through this study a research project was conducted to develop, implement and evaluate a multidisciplinary OSCE model within limited resources. This research project went through the steps of blueprinting, station writing, resources reallocation, implementation and finally evaluation. The developed model was implemented in the Primary Health Care (PHC) program which is one of the pillars of the Community-Based undergraduate curriculum of the Faculty of Medicine, Suez Canal University (FOM-SCU). Data for evaluation of the implemented OSCE model were derived from two resources. First, feedback of the students and assessors through self-administered questionnaires was obtained. Second, evaluation of the OSCE psychometrics was done. The deliverables of this research project included a set of validated integrated multi-disciplinary and low cost OSCE stations with an estimated reliability index of 0.6. After having this experience, we have a critical mass of faculty members trained on blueprinting and station writing and a group of trained assessors, facilitators and role players. Also there is a state of awareness among students on how to proceed in this type of OSCE which renders future implementation more feasible.

  3. Engine speed control apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishii, M.; Miyazaki, M.; Nakamura, N.

    1986-11-04

    This patent describes an engine speed control apparatus. The system comprises an actuator for adjusting an engine speed, a first unit for computing a desired engine speed, a second unit for detecting the actual engine speed, and a third unit for detecting the difference between the outputs of the first and second units. The system also includes a fourth unit for computing a control pulse width for the actuator in accordance with the output of the third unit, a fifth unit for generating a control signal, a sixth unit for driving the actuator in response to the output of themore » fifth unit, and a seventh unit for computing an optimal halt time to interrupt the driving of the actuator. The actuator is driven intermittently in conformity in the control pulse width and the halt time.« less

  4. Storage characteristics of multiple-donor pooled red blood cells compared to single-donor red blood cell units.

    PubMed

    Mathur, Aabhas; Chowdhury, Raquibul; Hillyer, Christopher D; Mitchell, W Beau; Shaz, Beth H

    2016-12-01

    Each unit of blood donated is processed and stored individually resulting in variability in the amount of red blood cells (RBCs) collected, RBC properties, and the 24-hour posttransfusion RBC survivability. As a result, each unit differs in its ability to deliver oxygen and potentially its effects on the recipient. The goal of this study was to investigate the storage of pooled RBCs from multiple donors in comparison to control standard RBC units. Two units of irradiated, leukoreduced RBCs of same ABO, D, E, C, and K antigen phenotype were collected from each of five donors using apheresis. One unit from each donor was pooled in a 2-L bag and remaining units were used as controls. After being pooled, RBCs were separated in five bags and stored at 4°C along with the controls. Quality indexes were measured on Days 2, 14, and 28 for all the units. Adenosine triphosphate assays for both pooled and controls showed a slight decrease from Day 2 to Day 28 (pooled/control from 5.22/5.24 to 4.35/4.33 µmol/g hemoglobin [Hb]). 2,3-Diphosphoglycerate was successfully rejuvenated for all RBC units on Day 28 (pooled 11.46 µmol/g Hb; control 11.86 µmol/g Hb). The results showed a nonsignificant difference between pooled and control units, with a general trend of lower standard deviation for pooled units when compared to controls. Pooled units have reduced unit-to-unit variability. Future exploration of their immunogenicity is required before using pooled units for transfusion. © 2016 AABB.

  5. 21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...

  6. 21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...

  7. Substantiation of Structure of Adaptive Control Systems for Motor Units

    NASA Astrophysics Data System (ADS)

    Ovsyannikov, S. I.

    2018-05-01

    The article describes the development of new electronic control systems, in particular motor units, for small-sized agricultural equipment. Based on the analysis of traffic control systems, the main course of development of the conceptual designs of motor units has been defined. The systems aimed to control the course motion of the motor unit in automatic mode using the adaptive systems have been developed. The article presents structural models of the conceptual motor units based on electrically controlled systems by the operation of drive motors and adaptive systems that make the motor units completely automated.

  8. Deflate decompressor

    DOEpatents

    Hamlet, Jason R [Albuquerque, NM; Robertson, Perry J [Albuquerque, NM; Pierson, Lyndon G [Albuquerque, NM; Olsberg, Ronald R [Albuquerque, NM

    2012-02-28

    A deflate decompressor includes at least one decompressor unit, a memory access controller, a feedback path, and an output buffer unit. The memory access controller is coupled to the decompressor unit via a data path and includes a data buffer to receive the data stream and temporarily buffer a first portion the data stream. The memory access controller transfers fixed length data units of the data stream from the data buffer to the decompressor unit with reference to a memory pointer pointing into the memory buffer. The feedback path couples the decompressor unit to the memory access controller to feed back decrement values to the memory access controller for updating the memory pointer. The decrement values each indicate a number of bits unused by the decompressor unit when decoding the fixed length data units. The output buffer unit buffers a second portion of the data stream after decompression.

  9. NIC atomic operation unit with caching and bandwidth mitigation

    DOEpatents

    Hemmert, Karl Scott; Underwood, Keith D.; Levenhagen, Michael J.

    2016-03-01

    A network interface controller atomic operation unit and a network interface control method comprising, in an atomic operation unit of a network interface controller, using a write-through cache and employing a rate-limiting functional unit.

  10. Highly parallel reconfigurable computer architecture for robotic computation having plural processor cells each having right and left ensembles of plural processors

    NASA Technical Reports Server (NTRS)

    Fijany, Amir (Inventor); Bejczy, Antal K. (Inventor)

    1994-01-01

    In a computer having a large number of single-instruction multiple data (SIMD) processors, each of the SIMD processors has two sets of three individual processor elements controlled by a master control unit and interconnected among a plurality of register file units where data is stored. The register files input and output data in synchronism with a minor cycle clock under control of two slave control units controlling the register file units connected to respective ones of the two sets of processor elements. Depending upon which ones of the register file units are enabled to store or transmit data during a particular minor clock cycle, the processor elements within an SIMD processor are connected in rings or in pipeline arrays, and may exchange data with the internal bus or with neighboring SIMD processors through interface units controlled by respective ones of the two slave control units.

  11. Daylight control system device and method

    DOEpatents

    Paton, John Douglas

    2007-03-13

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  12. Daylight control system, device and method

    DOEpatents

    Paton, John Douglas

    2012-08-28

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  13. Daylight control system device and method

    DOEpatents

    Paton, John Douglas

    2009-12-01

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  14. Interface For Fault-Tolerant Control System

    NASA Technical Reports Server (NTRS)

    Shaver, Charles; Williamson, Michael

    1989-01-01

    Interface unit and controller emulator developed for research on electronic helicopter-flight-control systems equipped with artificial intelligence. Interface unit interrupt-driven system designed to link microprocessor-based, quadruply-redundant, asynchronous, ultra-reliable, fault-tolerant control system (controller) with electronic servocontrol unit that controls set of hydraulic actuators. Receives digital feedforward messages from, and transmits digital feedback messages to, controller through differential signal lines or fiber-optic cables (thus far only differential signal lines have been used). Analog signals transmitted to and from servocontrol unit via coaxial cables.

  15. [Portable multi-purpose device for monitoring of physiological informations].

    PubMed

    Tamura, T; Togawa, T

    1983-05-01

    Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.

  16. Method and Apparatus for Improved Spatial Light Modulation

    NASA Technical Reports Server (NTRS)

    Soutar, Colin (Inventor); Juday, Richard D. (Inventor)

    2000-01-01

    A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain the optical processing objective.

  17. Method and Apparatus for Improved Spatial Light Modulation

    NASA Technical Reports Server (NTRS)

    Colin, Soutar (Inventor); Juday, Richard D. (Inventor)

    1999-01-01

    A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain die optical processing objective.

  18. Maximizing the Functional Status of Geriatric Patients in an Acute Community Hospital Setting.

    ERIC Educational Resources Information Center

    Meissner, Paul; And Others

    1989-01-01

    Compared patients (N=103) admitted to inpatient geriatric care unit focusing on restoration of functional status to control-unit patients (N=75). Found greater improvement in basic functional capabilities of study-unit than control-unit patients. Found mixed picture when length of stay and total charges of study- and control-unit patients were…

  19. Linear control of a boiler-turbine unit: analysis and design.

    PubMed

    Tan, Wen; Fang, Fang; Tian, Liang; Fu, Caifen; Liu, Jizhen

    2008-04-01

    Linear control of a boiler-turbine unit is discussed in this paper. Based on the nonlinear model of the unit, this paper analyzes the nonlinearity of the unit, and selects the appropriate operating points so that the linear controller can achieve wide-range performance. Simulation and experimental results at the No. 4 Unit at the Dalate Power Plant show that the linear controller can achieve the desired performance under a specific range of load variations.

  20. A Closed-Loop Proportional-Integral (PI) Control Software for Fully Mechanically Controlled Automated Electron Microscopic Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    REN, GANG; LIU, JINXIN; LI, HONGCHANG

    A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the resultsmore » to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.« less

  1. 28 CFR 541.41 - Institutional referral.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.41 Institutional referral. (a) The Warden shall submit a recommendation for referral of an inmate for placement in a control unit to... following factors in a recommendation for control unit placement. (1) Any incident during confinement in...

  2. Comparison of Achievable Magnetic Fields with Superconducting and Cryogenic Permanent Magnet Undulators – A Comprehensive Study of Computed and Measured Values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moog, E. R.; Dejus, R. J.; Sasaki, S.

    2017-01-01

    Magnetic modeling was performed to estimate achievable magnetic field strengths of superconducting undulators (SCUs) and to compare them with those of cryogenically cooled permanent magnet undulators (CPMUs). Starting with vacuum (beam stay-clear) gaps of 4.0 and 6.0 mm, realistic allowances for beam chambers (in the SCU case) and beam liners (in the CPMU case) were added. (A 6.0-mm vacuum gap is planned for the upgraded APS). The CPMU magnetic models consider both CPMUs that use NdFeB magnets at ~150 K and PrFeB magnets at 77 K. Parameters of the magnetic models are presented along with fitted coefficients of a Halbach-typemore » expression for the field dependence on the gap-to-period ratio. Field strengths for SCUs are estimated using a scaling law for planar SCUs; an equation for that is given. The SCUs provide higher magnetic fields than the highest-field CPMUs – those using PrFeB at 77 K – for period lengths longer than ~14 mm for NbTi-based SCUs and ~10 mm for Nb3Sn-based SCUs. To show that the model calculations and scaling law results are realistic, they are compared to CPMUs that have been built and NbTi-based SCUs that have been built. Brightness tuning curves of CPMUs (PrFeB) and SCUs (NbTi) for the upgraded APS lattice are also provided for realistic period lengths.« less

  3. Personal customizing exercise with a wearable measurement and control unit.

    PubMed

    Wang, Zhihui; Kiryu, Tohru; Tamura, Naoki

    2005-06-28

    Recently, wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of customizing machine-based exercise on an individual basis by relying on biosignal-based controls. We propose a new wearable unit design equipped with measurement and control functions to support the customization process. The wearable unit can measure the heart rate and electromyogram signals during exercise performance and output workload control commands to the exercise machines. The workload is continuously tracked with exercise programs set according to personally customized workload patterns and estimation results from the measured biosignals by a fuzzy control method. Exercise programs are adapted by relying on a computer workstation, which communicates with the wearable unit via wireless connections. A prototype of the wearable unit was tested together with an Internet-based cycle ergometer system to demonstrate that it is possible to customize exercise on an individual basis. We tested the wearable unit in nine people to assess its suitability to control cycle ergometer exercise. The results confirmed that the unit could successfully control the ergometer workload and continuously support gradual changes in physical activities. The design of wearable units equipped with measurement and control functions is an important step towards establishing a convenient and continuously supported wellness environment.

  4. Real-time performance assessment and adaptive control for a water chiller unit in an HVAC system

    NASA Astrophysics Data System (ADS)

    Bai, Jianbo; Li, Yang; Chen, Jianhao

    2018-02-01

    The paper proposes an adaptive control method for a water chiller unit in a HVAC system. Based on the minimum variance evaluation, the adaptive control method was used to realize better control of the water chiller unit. To verify the performance of the adaptive control method, the proposed method was compared with an a conventional PID controller, the simulation results showed that adaptive control method had superior control performance to that of the conventional PID controller.

  5. 78 FR 29055 - State Medicaid Fraud Control Units; Data Mining

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-17

    ...] State Medicaid Fraud Control Units; Data Mining AGENCY: Office of Inspector General (OIG), HHS. ACTION... Fraud Control Units (MFCU) from using Federal matching funds to identify fraud through screening and... Control Number (OCN) 0990-0162. Table 2 indicates the paperwork burden associated with the requirements of...

  6. Effect of accuracy of wind power prediction on power system operator

    NASA Technical Reports Server (NTRS)

    Schlueter, R. A.; Sigari, G.; Costi, T.

    1985-01-01

    This research project proposed a modified unit commitment that schedules connection and disconnection of generating units in response to load. A modified generation control is also proposed that controls steam units under automatic generation control, fast responding diesels, gas turbines and hydro units under a feedforward control, and wind turbine array output under a closed loop array control. This modified generation control and unit commitment require prediction of trend wind power variation one hour ahead and the prediction of error in this trend wind power prediction one half hour ahead. An improved meter for predicting trend wind speed variation is developed. Methods for accurately simulating the wind array power from a limited number of wind speed prediction records was developed. Finally, two methods for predicting the error in the trend wind power prediction were developed. This research provides a foundation for testing and evaluating the modified unit commitment and generation control that was developed to maintain operating reliability at a greatly reduced overall production cost for utilities with wind generation capacity.

  7. Adaptive control system having hedge unit and related apparatus and methods

    NASA Technical Reports Server (NTRS)

    Johnson, Eric Norman (Inventor); Calise, Anthony J. (Inventor)

    2003-01-01

    The invention includes an adaptive control system used to control a plant. The adaptive control system includes a hedge unit that receives at least one control signal and a plant state signal. The hedge unit generates a hedge signal based on the control signal, the plant state signal, and a hedge model including a first model having one or more characteristics to which the adaptive control system is not to adapt, and a second model not having the characteristic(s) to which the adaptive control system is not to adapt. The hedge signal is used in the adaptive control system to remove the effect of the characteristic from a signal supplied to an adaptation law unit of the adaptive control system so that the adaptive control system does not adapt to the characteristic in controlling the plant.

  8. Hydraulic actuator mechanism to control aircraft spoiler movements through dual input commands

    NASA Technical Reports Server (NTRS)

    Irick, S. C. (Inventor)

    1981-01-01

    An aircraft flight spoiler control mechanism is described. The invention enables the conventional, primary spoiler control system to retain its operational characteristics while accommodating a secondary input controlled by a conventional computer system to supplement the settings made by the primary input. This is achieved by interposing springs between the primary input and the spoiler control unit. The springs are selected to have a stiffness intermediate to the greater force applied by the primary control linkage and the lesser resistance offered by the spoiler control unit. Thus, operation of the primary input causes the control unit to yield before the springs, yet, operation of the secondary input, acting directly on the control unit, causes the springs to yield and absorb adjustments before they are transmitted into the primary control system.

  9. Model of Rescue Units Control in Event of Potential Emergency

    NASA Astrophysics Data System (ADS)

    Kalach, A. V.; Kravchenko, A. S.; Soloviev, A. S.; Nesterov, A. A.

    2018-05-01

    A problem of organization and efficiency improvement of the system controlling the rescue units of the Ministry of Civil Defense and Emergency Response of the Russian Federation considered using the example of potential hydrological emergency, a model of a system for controlling rescue units in the event of potential hydrological emergency. The problem solution is based on mathematical models of operational control of rescue units and assessment of a hydrological situation of area flooding.

  10. Personal customizing exercise with a wearable measurement and control unit

    PubMed Central

    Wang, Zhihui; Kiryu, Tohru; Tamura, Naoki

    2005-01-01

    Background Recently, wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of customizing machine-based exercise on an individual basis by relying on biosignal-based controls. We propose a new wearable unit design equipped with measurement and control functions to support the customization process. Methods The wearable unit can measure the heart rate and electromyogram signals during exercise performance and output workload control commands to the exercise machines. The workload is continuously tracked with exercise programs set according to personally customized workload patterns and estimation results from the measured biosignals by a fuzzy control method. Exercise programs are adapted by relying on a computer workstation, which communicates with the wearable unit via wireless connections. A prototype of the wearable unit was tested together with an Internet-based cycle ergometer system to demonstrate that it is possible to customize exercise on an individual basis. Results We tested the wearable unit in nine people to assess its suitability to control cycle ergometer exercise. The results confirmed that the unit could successfully control the ergometer workload and continuously support gradual changes in physical activities. Conclusion The design of wearable units equipped with measurement and control functions is an important step towards establishing a convenient and continuously supported wellness environment. PMID:15982425

  11. Unit area control in California forests

    Treesearch

    William E. Hallin

    1951-01-01

    There is a definite distinction between the basic concept of unit area control and the specific techniques or treatments used for specific units. Unit area control as a term was first used in connection with a cutting trial in the sugar pine-fir type; consequently, many foresters think the term refers merely to the technique used in sugar pine management, This is not...

  12. Development of a wearable measurement and control unit for personal customizing machine-supported exercise.

    PubMed

    Wang, Zhihui; Tamura, Naoki; Kiryu, Tohru

    2005-01-01

    Wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of personal customizing machine-supported exercise that have biosignal-based controls. In this paper, we propose a new wearable unit design equipped with measurement and control functions to support the personal customization process. The wearable unit can measure the heart rate and electromyogram signals during exercise and output workload control commands to the exercise machines. We then applied a prototype of the wearable unit to an Internet-based cycle ergometer system. The wearable unit was examined using twelve young people to check its feasibility. The results verified that the unit could successfully adapt to the control of the workload and was effective for continuously supporting gradual changes in physical activities.

  13. HEMP (high-altitude electromagnetic pulse) test and analysis of selected recloser-control units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, T.K.; Sands, S.H.; Tesche, F.M.

    A simulated HEMP test was performed on power line recloser-control units in the ARES facility during the month of October 1988. Two types of recloser-control units were tested: an electronic control unit presently in wide use in electric power distribution systems and a new microprocessor based unit presently being introduced to electric utilities. It was found that the ARES fields did not cause reproducible disruptive failure of the equipment. Minor upsets, which were considered to be non-disruptive to the recloser operation, were observed. The test results were compared to the results of an analysis from a previous study and itmore » is concluded that the probability of disruptive failure of field operating recloser-control units subjected to a nominal unclassified HEMP environment is small. 3 refs., 30 figs., 1 tab.« less

  14. Control system for several rotating mirror camera synchronization operation

    NASA Astrophysics Data System (ADS)

    Liu, Ningwen; Wu, Yunfeng; Tan, Xianxiang; Lai, Guoji

    1997-05-01

    This paper introduces a single chip microcomputer control system for synchronization operation of several rotating mirror high-speed cameras. The system consists of four parts: the microcomputer control unit (including the synchronization part and precise measurement part and the time delay part), the shutter control unit, the motor driving unit and the high voltage pulse generator unit. The control system has been used to control the synchronization working process of the GSI cameras (driven by a motor) and FJZ-250 rotating mirror cameras (driven by a gas driven turbine). We have obtained the films of the same objective from different directions in different speed or in same speed.

  15. NASA three-laser airborne differential absorption lidar system electronics

    NASA Technical Reports Server (NTRS)

    Allen, R. J.; Copeland, G. D.

    1984-01-01

    The system control and signal conditioning electronics of the NASA three laser airborne differential absorption lidar (DIAL) system are described. The multipurpose DIAL system was developed for the remote measurement of gas and aerosol profiles in the troposphere and lower stratosphere. A brief description and photographs of the majority of electronics units developed under this contract are presented. The precision control system; which includes a master control unit, three combined NASA laser control interface/quantel control units, and three noise pulse discriminator/pockels cell pulser units; is described in detail. The need and design considerations for precision timing and control are discussed. Calibration procedures are included.

  16. Operating manual for the miniservo-control tester

    USGS Publications Warehouse

    Rapp, W.L.

    1986-01-01

    Ever since the implementation of servo-control units (regular and minimodels) with manometers at U. S. Geological Survey streamflow stations, the need for an effective and efficient servo-control unit tester has been paramount among field personnel. In numerous cases, servo-control unit failures were blamed on battery failures and vice versa. There was no valid instrument to definitively identify cause of failure, let alone properly diagnose the servo-control/manometer system. In 1983, two servo-control unit testers were developed and fabricated. One was mechanical in fabrication, operation, and serviceability; the other was electronic. The testers were extensively used and evaluated in Maine, Ohio, Kansas, and Louisiana under a wide range of environmental conditions. The consensus to integrate the best aspects of both testers into one instrument allowed the Survey to finally solve its long-time need for an effective, efficient servo-control unit tester. (USGS)

  17. Multichannel optical sensing device

    DOEpatents

    Selkowitz, S.E.

    1985-08-16

    A multichannel optical sensing device is disclosed, for measuring the outdoor sky luminance or illuminance or the luminance or illuminance distribution in a room, comprising a plurality of light receptors, an optical shutter matrix including a plurality of liquid crystal optical shutter elements operable by electrical control signals between light transmitting and light stopping conditions, fiber optical elements connected between the receptors and the shutter elements, a microprocessor based programmable control unit for selectively supplying control signals to the optical shutter elements in a programmable sequence, a photodetector including an optical integrating spherical chamber having an input port for receiving the light from the shutter matrix and at least one detector element in the spherical chamber for producing output signals corresponding to the light, and output units for utilizing the output signals including a storage unit having a control connection to the microprocessor based programmable control unit for storing the output signals under the sequence control of the programmable control unit.

  18. Multichannel optical sensing device

    DOEpatents

    Selkowitz, Stephen E.

    1990-01-01

    A multichannel optical sensing device is disclosed, for measuring the outr sky luminance or illuminance or the luminance or illuminance distribution in a room, comprising a plurality of light receptors, an optical shutter matrix including a plurality of liquid crystal optical shutter elements operable by electrical control signals between light transmitting and light stopping conditions, fiber optic elements connected between the receptors and the shutter elements, a microprocessor based programmable control unit for selectively supplying control signals to the optical shutter elements in a programmable sequence, a photodetector including an optical integrating spherical chamber having an input port for receiving the light from the shutter matrix and at least one detector element in the spherical chamber for producing output signals corresponding to the light, and output units for utilizing the output signals including a storage unit having a control connection to the microprocessor based programmable control unit for storing the output signals under the sequence control of the programmable control unit.

  19. Neuronal codes for the inhibitory control of impulsive actions in the rat infralimbic cortex.

    PubMed

    Tsutsui-Kimura, Iku; Ohmura, Yu; Izumi, Takeshi; Matsushima, Toshiya; Amita, Hidetoshi; Yamaguchi, Taku; Yoshida, Takayuki; Yoshioka, Mitsuhiro

    2016-01-01

    Poor impulse control is a debilitating condition observed in various psychiatric disorders and could be a risk factor for drug addiction, criminal involvement, and suicide. The rat infralimbic cortex (IL), located in the ventral portion of the medial prefrontal cortex, has been implicated in impulse control. To elucidate the neurophysiological basis of impulse control, we recorded single unit activity in the IL of a rat performing a 3-choiceserial reaction time task (3-CSRTT) and 2-choice task (2-CT), which are animal models for impulsivity. The inactivation of IL neuronal activity with an injection of muscimol (0.1 μg /side) disrupted impulse control in the 3-CSRTT. More than 60% (38/56) of isolated IL units were linked to impulse control, while approximately 30% of all units were linked to attentional function in the 3-CSRTT. To avoid confounding motor-related units with the impulse control-related units, we further conducted the 2-CT in which the animals' motor activities were restricted during recording window. More than 30% (14/44) of recorded IL units were linked to impulse control in the 2-CT. Several types of impulse control-related units were identified. Only 16% of all units were compatible with the results of the muscimol experiment, which showed a transient decline in the firing rate immediately before the release of behavioral inhibition. This is the first study to elucidate the neurophysiological basis of impulse control in the IL and to propose that IL neurons control impulsive actions in a more complex manner than previously considered. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. 46 CFR 161.002-10 - Automatic fire detecting system control unit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...

  1. 46 CFR 161.002-10 - Automatic fire detecting system control unit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...

  2. 46 CFR 161.002-10 - Automatic fire detecting system control unit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...

  3. 46 CFR 161.002-10 - Automatic fire detecting system control unit.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... inches) or other audible alarm that has an equivalent sound level and that is mounted at the control unit... section. (4) Non-interference. The control unit shall be so arranged as to permit one or any number of... the visible alarm to remain until the trouble has been corrected. (3) Non-interference. The control...

  4. Flow-Control Unit For Nitrogen And Hydrogen Gases

    NASA Technical Reports Server (NTRS)

    Chang, B. J.; Novak, D. W.

    1990-01-01

    Gas-flow-control unit installed and removed as one piece replaces system that included nine separately serviced components. Unit controls and monitors flows of nitrogen and hydrogen gases. Designed for connection via fluid-interface manifold plate, reducing number of mechanical fluid-interface connections from 18 to 1. Unit provides increasing reliability, safety, and ease of maintenance, and for reducing weight, volume, and power consumption.

  5. 40 CFR 75.19 - Optional SO2, NOX, and CO2 emissions calculation for low mass emissions (LME) units.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (or group of identical units) equipped with SCR (or SNCR) and uses dry low-NOX technology to control... with add-on NOX emission controls, and for units that use dry low-NOX technology, the owner or operator... mass emissions unit that uses dry low-NOX premix technology to control NOX emissions, proper operation...

  6. 40 CFR 63.1281 - Control equipment requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... requirements for sources except small glycol dehydration units. Owners and operators of small glycol dehydration units shall comply with the control requirements in paragraph (f) of this section. (1) The control... or operator shall determine glycol dehydration unit baseline operations (as defined in § 63.1271...

  7. 40 CFR 63.1281 - Control equipment requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... requirements for sources except small glycol dehydration units. Owners and operators of small glycol dehydration units shall comply with the control requirements in paragraph (f) of this section. (1) The control... or operator shall determine glycol dehydration unit baseline operations (as defined in § 63.1271...

  8. Preventing patient-to-worker violence in hospitals: outcome of a randomized controlled intervention

    PubMed Central

    Arnetz, Judith E.; Hamblin, Lydia; Russell, Jim; Upfal, Mark J.; Luborsky, Mark; Janisse, James; Essenmacher, Lynnette

    2016-01-01

    Objective To evaluate the effects of a randomized controlled intervention on the incidence of patient-to-worker (Type II) violence and related injury in hospitals. Methods Forty-one units across 7 hospitals were randomized into intervention (n=21) and control (n=20) groups. Intervention units received unit-level violence data to facilitate development of an action plan for violence prevention; no data were presented to control units. Main outcomes were rates of violent events and injuries across study groups over time. Results Six months post-intervention, incident rate ratios of violent events were significantly lower on intervention units compared to controls (IRR 0.48, 95% CI 0.29-0.80). At 24 months, the risk for violence-related injury was lower on intervention units, compared to controls (IRR 0.37, 95% CI 0.17-0.83). Conclusion This data-driven, worksite-based intervention was effective in decreasing risks of patient-to-worker violence and related injury. PMID:28045793

  9. Drive Control System for Pipeline Crawl Robot Based on CAN Bus

    NASA Astrophysics Data System (ADS)

    Chen, H. J.; Gao, B. T.; Zhang, X. H.; Deng2, Z. Q.

    2006-10-01

    Drive control system plays important roles in pipeline robot. In order to inspect the flaw and corrosion of seabed crude oil pipeline, an original mobile pipeline robot with crawler drive unit, power and monitor unit, central control unit, and ultrasonic wave inspection device is developed. The CAN bus connects these different function units and presents a reliable information channel. Considering the limited space, a compact hardware system is designed based on an ARM processor with two CAN controllers. With made-to-order CAN protocol for the crawl robot, an intelligent drive control system is developed. The implementation of the crawl robot demonstrates that the presented drive control scheme can meet the motion control requirements of the underwater pipeline crawl robot.

  10. Wireless power charging using point of load controlled high frequency power converters

    DOEpatents

    Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.

    2015-10-13

    An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.

  11. 22 CFR 46.2 - Authority of departure-control officer to prevent alien's departure from the United States.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Authority of departure-control officer to prevent alien's departure from the United States. 46.2 Section 46.2 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.2 Authority of departure-control officer...

  12. 22 CFR 46.2 - Authority of departure-control officer to prevent alien's departure from the United States.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Authority of departure-control officer to prevent alien's departure from the United States. 46.2 Section 46.2 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.2 Authority of departure-control officer...

  13. 22 CFR 46.2 - Authority of departure-control officer to prevent alien's departure from the United States.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Authority of departure-control officer to prevent alien's departure from the United States. 46.2 Section 46.2 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.2 Authority of departure-control officer...

  14. 22 CFR 46.2 - Authority of departure-control officer to prevent alien's departure from the United States.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Authority of departure-control officer to prevent alien's departure from the United States. 46.2 Section 46.2 Foreign Relations DEPARTMENT OF STATE VISAS CONTROL OF ALIENS DEPARTING FROM THE UNITED STATES § 46.2 Authority of departure-control officer...

  15. Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

    NASA Technical Reports Server (NTRS)

    Soltis, James V.

    1998-01-01

    The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

  16. Cu(II) and Cu(I) complexes with 1,2-dithiosquarate as a ligand; from molecular compounds to supramolecular network structures

    NASA Astrophysics Data System (ADS)

    Calatayud, M. Luisa; Castro, Isabel; Julve, Miguel; Sletten, Jorunn

    2008-03-01

    Four new complexes of copper(II) and/or copper(I) with 1,2-dtsq as a ligand have been synthesized and characterized by single crystal X-ray diffraction methods, [Cu II(terpy)(1,2-dtsq)] ( 1), [Cu II(dmen)(1,2-dtsq)] n ( 2), {[Cu II(dmen) 2][Cu I(1,2-dtsq)] 2} n·2nH 2O( 3) and {[Cu II(men) 2][Cu I (1,2-dtsq)] 2} n·nH 2O ( 4) (1,2-dtsq = 1,2-dithiosquarate, dianion of 3,4-dimercapto-1-cyclobutene-1,2-dione; dmen = N, N-dimethylethylenediamine; men = N-methylethylenediamine, terpy = 2,2':6,2″-terpyridine). Compound 1 consists of neutral [Cu II(terpy)(1,2-dtsq)] mononuclear units which are held together by O⋯H-C and van der Waals interactions. Compound 2 is built of neutral [Cu II(dmen)(1,2-dtsq)] entities which are connected through weak Cu-S (pairs) and Cu-O (single) interactions into a layer structure. The structures of 3 and 4 feature polynuclear [Cu(1,2-dtsq)]nn- chains, in which dtsq groups are linking copper(I) ions in the μ-1,1, μ-1,1,1 and μ-1,2 bridging modes. The dtsq groups in these chains connect to the copper(II) ions of the [Cu IIL 2] 2+ cations [L being the bidentate dmen ( 3) and men ( 4) ligands], but in different manners in the two structures. The connections in compound 3 are unsymmetrical, so that columns of {[Cu II(dmen) 2][Cu I(1,2-dtsq)] 2} n where the copper(II) ions bind to 1,2-dtsq oxygen atoms with relatively strong axial bonds may be identified. These columns are further connected to each other through weak axial Cu II⋯S interactions, creating a three-dimensional (3D) network with channels containing the solvent water. In compound 4, on the other hand, the two crystallographically independent cations each forms a symmetrical link between the anionic chains through, respectively, O-Cu II-O and S-Cu II-S axial bonds, again creating a 3D structure with channels running parallel to the chain axis. The reduction of copper(II) to copper(I) by 1,2-dtsq is precluded when the coordination sphere of the copper(II) ion is partially blocked with the tridentate terpy ligand whereas this process occurs when the blocking ligands are the bidentate dmen and men groups.

  17. Photovoltaic Powering And Control System For Electrochromic Windows

    DOEpatents

    Schulz, Stephen C.; Michalski, Lech A.; Volltrauer, Hermann N.; Van Dine, John E.

    2000-04-25

    A sealed insulated glass unit is provided with an electrochromic device for modulating light passing through the unit. The electrochromic device is controlled from outside the unit by a remote control electrically unconnected to the device. Circuitry within the unit may be magnetically controlled from outside. The electrochromic device is powered by a photovoltaic cells. The photovoltaic cells may be positioned so that at least a part of the light incident on the cell passes through the electrochromic device, providing a form of feedback control. A variable resistance placed in parallel with the electrochromic element is used to control the response of the electrochromic element to changes in output of the photovoltaic cell.

  18. Experience with ethylene plant computer control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nasi, M.; Darby, M.L.; Sourander, M.

    This article discusses the control strategies, results and opinions of management and operations of a computer based ethylene plant control system. The ethylene unit contains 9 cracking heaters, and its nameplate capacity is 200,000 tpa ethylene. Reports on control performance during different unit loading and using different feedstock types. By converting the yield and utility consumption benefits due to computer control into monetary units, the payback time of the system is less than 2 yrs.

  19. An investigation of collisions between fiber positioning units in LAMOST

    NASA Astrophysics Data System (ADS)

    Liu, Xiao-Jie; Wang, Gang

    2016-04-01

    The arrangement of fiber positioning units in the LAMOST focal plane may lead to collisions during the fiber allocation process. To avoid these collisions, a software-based protection system has to abandon some targets located in the overlapping field of adjacent fiber units. In this paper, we first analyze the probability of collisions between fibers and infer their possible reasons. It is useful to solve the problem of collisions among fiber positioning units so as to improve the efficiency of LAMOST. Based on this, a collision handling system is designed by using a master-slave control structure between the micro control unit and microcomputer. Simulated experiments validate that the system can provide real-time inspection and swap information between the fiber unit controllers and the main controller.

  20. Near-memory data reorganization engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gokhale, Maya; Lloyd, G. Scott

    A memory subsystem package is provided that has processing logic for data reorganization within the memory subsystem package. The processing logic is adapted to reorganize data stored within the memory subsystem package. In some embodiments, the memory subsystem package includes memory units, a memory interconnect, and a data reorganization engine ("DRE"). The data reorganization engine includes a stream interconnect and DRE units including a control processor and a load-store unit. The control processor is adapted to execute instructions to control a data reorganization. The load-store unit is adapted to process data move commands received from the control processor via themore » stream interconnect for loading data from a load memory address of a memory unit and storing data to a store memory address of a memory unit.« less

  1. Unit Testing for Command and Control Systems

    NASA Technical Reports Server (NTRS)

    Alexander, Joshua

    2018-01-01

    Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.

  2. Dynamically limiting energy consumed by cooling apparatus

    DOEpatents

    Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.

    2015-05-26

    Cooling apparatuses and methods are provided which include one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is coupled to the N controllable components, and dynamically adjusts operation of the N controllable components, based on Z input parameters and one or more specified constraints, to provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.

  3. Improved control system power unit for large parachutes

    NASA Technical Reports Server (NTRS)

    Chandler, J. A.; Grubbs, T. M.

    1968-01-01

    Improved control system power unit drives the control surfaces of very large controllable parachutes. The design features subassemblies for determining control surface position and cable loading, and protection of the load sensor against the possibility of damage during manipulation.

  4. A Network Thermodynamic Framework for the Analysis and Control Design of Large-Scale Dynamical Systems

    DTIC Science & Technology

    2006-03-31

    Nonnegative Dynamical Sys- tems................................................. 18 2.10. Adaptive Control for General Anesthesia and Intensive Care...Unit Sedation 20 2.11. Neural Network Adaptive Control for Intensive Care Unit Sedation and In- traoperative Anesthesia ...control for operating room hypnosis and intefisive care unit sedation. 1.3. Goals of this Report The main goal of this report is to summarize the

  5. Strap-Down Inertial Systems

    DTIC Science & Technology

    1978-05-01

    navigation computer (SNC), sepa- rate alterable memory units for the computer, a control /display unit (CDU), a computer control unit (CCU), and a non ...AND SYSTEM Advisory Group for Aerospace Research and Development, Paris (France). Presented at the 15th Meeting of the Guidance and Control Panel of... Group , Redondo Beach, Calif.) American Institute of Aeronautics and Astronautics, Guidance and Control Conference, Key Biscayne, Fla., August 20-22

  6. 78 FR 721 - California State Nonroad Engine Pollution Control Standards; Transport Refrigeration Units...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-04

    ...; Transport Refrigeration Units; Request for Authorization; Opportunity for Public Hearing and Comment AGENCY... Diesel-Fueled Transport Refrigeration Units (TRU) and TRU Generator Sets and Facilities Where TRUs...''), regarding its ``Airborne Toxic Control Measure for In-Use Diesel-Fueled Transport Refrigeration Units (TRU...

  7. Spool-type control valve assembly with reduced spool stroke for hydraulic belt-and-pulley type continuously variable transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Itoh, H.; Akashi, T.; Takada, M.

    1987-03-31

    This patent describes a hydraulic control system for controlling a speed ratio of a hydraulically-operated continuously variable transmission of belt-and-pulley type having a variable-diameter pulley and a hydraulic cylinder for changing an effective diameter of the variable diameter-pulley of the transmission. The hydraulic control system includes a speed-ratio control valve assembly for controlling the supply and discharge of a pressurized fluid to and from the hydraulic cylinder to thereby change the speed ratio of the transmission. The speed-ratio control valve assembly comprises: a shift-direction switching valve unit disposed in fluid supply and discharge conduits communicating with the hydraulic cylinder, formore » controlling a direction in which the speed ratio of the transmission is varied; a shift-speed control valve unit of spool-valve type connected to the shift-direction switching valve unit. The shift-speed control valve unit is selectively placed in a first state in which the fluid supply and discharge flows to and from the hydraulic cylinder through the conduits are permitted, or in a second state in which the fluid supply flow is restricted while the fluid discharge flow is inhibited; an actuator means for placing the shift speed control valve unit alternately in the first and second states to control a rate of variation in the speed ratio of the transmission in the direction established by the shift-direction switching valve unit.« less

  8. A liquid-delivery device that provides precise reward control for neurophysiological and behavioral experiments.

    PubMed

    Mitz, Andrew R

    2005-10-15

    Behavioral neurophysiology and other kinds of behavioral research often involve the delivery of liquid rewards to experimental subjects performing some kind of operant task. Available systems use gravity or pumps to deliver these fluids, but such methods are poorly suited to moment-to-moment control of the volume, timing, and type of fluid delivered. The design described here overcomes these limitations using an electronic control unit, a pressurized reservoir unit, and an electronically controlled solenoid. The control unit monitors reservoir pressure and provides precisely timed solenoid activation signals. It also stores calibration tables and does on-the-fly interpolation to support computer-controlled delivery calibrated directly in milliliters. The reservoir provides pressurized liquid to a solenoid mounted near the subject. Multiple solenoids, each supplied by a separate reservoir unit and control unit, can be stacked in close proximity to allow instantaneous selection of which liquid reward is delivered. The precision of droplet delivery was verified by weighing discharged droplets on a commercial analytical balance.

  9. 78 FR 38970 - California State Nonroad Engine Pollution Control Standards; Within-the-Scope Determination for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-28

    ... Control Measure for In-Use Diesel-Fueled Transport Refrigeration Units (TRU) and TRU Generator Sets and... Control Measure for In-Use Diesel-Fueled Transport Refrigeration Units (TRU) and TRU Generator Sets and...-Fueled Transport Refrigeration Units (TRU) and TRU Generator Sets and Facilities Where TRUs Operate Be...

  10. 46 CFR 161.002-8 - Automatic fire detecting systems, general requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detecting system shall consist of a power supply; a control unit on which are located visible and audible... control unit. Power failure alarm devices may be separately housed from the control unit and may be combined with other power failure alarm systems when specifically approved. (b) [Reserved] [21 FR 9032, Nov...

  11. 46 CFR 161.002-8 - Automatic fire detecting systems, general requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... detecting system shall consist of a power supply; a control unit on which are located visible and audible... control unit. Power failure alarm devices may be separately housed from the control unit and may be combined with other power failure alarm systems when specifically approved. (b) [Reserved] [21 FR 9032, Nov...

  12. Quality Control Technician.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This document contains 18 units to consider for use in a tech prep competency profile for the occupation of quality control technician. All the units listed will not necessarily apply to every situation or tech prep consortium, nor will all the competencies within each unit be appropriate. Several units appear within each specific occupation and…

  13. Instrumentation Control Technician.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This document contains 22 units to consider for use in a tech prep competency profile for the occupation of instrumentation control technician. All the units listed will not necessarily apply to every situation or tech prep consortium, nor will all the competencies within each unit be appropriate. Several units appear within each specific…

  14. Design and Evaluation of a Fully Implantable Control Unit for Blood Pumps

    PubMed Central

    Unthan, Kristin; Gräf, Felix; Laumen, Marco; Finocchiaro, Thomas; Sommer, Christoph; Lanmüller, Hermann; Steinseifer, Ulrich

    2015-01-01

    As the number of donor hearts is limited while more and more patients suffer from end stage biventricular heart failure, Total Artificial Hearts become a promising alternative to conventional treatment. While pneumatic devices sufficiently supply the patients with blood flow, the patient's quality of life is limited by the percutaneous pressure lines and the size of the external control unit. This paper describes the development of the control unit of the ReinHeart, a fully implantable Total Artificial Heart. General requirements for any implantable control unit are defined from a technical and medical point of view: necessity of a Transcutaneous Energy Transmission, autonomous operation, safety, geometry, and efficiency. Based on the requirements, a prototype is designed; it incorporates a LiFePo4 battery pack with charger, a rectifier for transcutaneous energy transmission, the motor's driver electronics, and a microcontroller which monitors and controls all functions. In validation tests, the control unit demonstrated a stable operation on TET and battery supply and a safe switching from one supply to the other. The overall mean efficiency is 14% on TET and 22% on battery supply. The control unit is suitable for chronic animal trials of the ReinHeart. PMID:26583095

  15. Ferromagnetic coupling by spin polarization in a trinuclear copper(II) metallacyclophane with a triangular cage-like structure.

    PubMed

    Dul, Marie-Claire; Ottenwaelder, Xavier; Pardo, Emilio; Lescouëzec, Rodrigue; Journaux, Yves; Chamoreau, Lise-Marie; Ruiz-García, Rafael; Cano, Joan; Julve, Miguel; Lloret, Francesc

    2009-06-15

    A series of trinuclear copper(II) complexes of general formula A(6)[Cu(3)L(2)] x nH(2)O [L = benzene-1,3,5-tris(oxamate); A = Li(+) (n = 8), 1a; Na(+) (n = 11.5), 1b; and K(+) (n = 8.5), 1c] have been synthesized, and they have been structurally and magnetically characterized. X-ray diffraction on single crystals of 1c shows the presence of three square-planar copper(II)-bis(oxamato) moieties which are connected by a double benzene-1,3,5-triyl skeleton to give a unique metallacyclophane-type triangular cage. The copper basal planes are virtually orthogonal to the two benzene rings, which adopt an almost perfect face-to-face alignment. Complexes 1a-c exhibit a quartet (S = 3/2) ground spin state resulting from the moderate ferromagnetic coupling (J values in the range of +7.3 to +16.5 cm(-1)) between the three Cu(II) ions across the two benzene-1,3,5-tris(amidate) bridges [H = -J(S(1) x S(2) + S(2) x S(3) + S(3) x S(1)) with S(1) = S(2) = S(3) = S(Cu) = 1/2]. Density functional theory calculations on the S = 3/2 Cu(II)(3) ground spin state of 1c support the occurrence of a spin polarization mechanism for the propagation of the exchange interaction, as evidenced by the sign alternation of the spin density in the 1,3,5-substituted benzene spacers.

  16. Experience in connecting the power generating units of thermal power plants to automatic secondary frequency regulation within the united power system of Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhukov, A. V.; Komarov, A. N.; Safronov, A. N.

    The principles of central control of the power generating units of thermal power plants by automatic secondary frequency and active power overcurrent regulation systems, and the algorithms for interactions between automatic power control systems for the power production units in thermal power plants and centralized systems for automatic frequency and power regulation, are discussed. The order of switching the power generating units of thermal power plants over to control by a centralized system for automatic frequency and power regulation and by the Central Coordinating System for automatic frequency and power regulation is presented. The results of full-scale system tests ofmore » the control of power generating units of the Kirishskaya, Stavropol, and Perm GRES (State Regional Electric Power Plants) by the Central Coordinating System for automatic frequency and power regulation at the United Power System of Russia on September 23-25, 2008, are reported.« less

  17. Decisive Action Training Environment at the Joint Readiness Training Center, Vol.14: Company-Level Combined Arms Maneuver

    DTIC Science & Technology

    2016-12-01

    isolate the breach. “At the company level, direct fire control measures are effective only if the entire unit has a common understanding of what they mean... units must have the same control measures , and these measures must be shared with 66 CENTER FOR ARMY LESSONS LEARNED adjacent units for them to be...Graphic control measures • Adjacent unit coordination • CCIRs • Command and signal • Rules of engagement (ROE) Mission Orders in Practice During

  18. A miniaturized digital telemetry system for physiological data transmission

    NASA Technical Reports Server (NTRS)

    Portnoy, W. M.; Stotts, L. J.

    1978-01-01

    A physiological date telemetry system, consisting basically of a portable unit and a ground base station was designed, built, and tested. The portable unit to be worn by the subject is composed of a single crystal controlled transmitter with AM transmission of digital data and narrowband FM transmission of voice; a crystal controlled FM receiver; thirteen input channels follwed by a PCM encoder (three of these channels are designed for ECG data); a calibration unit; and a transponder control system. The ground base station consists of a standard telemetry reciever, a decoder, and an FM transmitter for transmission of voice and transponder signals to the portable unit. The ground base station has complete control of power to all subsystems in the portable unit. The phase-locked loop circuit which is used to decode the data, remains in operation even when the signal from the portable unit is interrupted.

  19. Dynamically limiting energy consumed by cooling apparatus

    DOEpatents

    Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.

    2015-06-09

    Cooling methods are provided which include providing: one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is also provided to dynamically adjust operation of the N controllable components, based on Z input parameters and one or more specified constraints, and provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.

  20. Effects of Hydrogen Peroxide on Dental Unit Biofilms and Treatment Water Contamination

    PubMed Central

    Lin, Shih-Ming; Svoboda, Kathy K.H.; Giletto, Anthony; Seibert, Jeff; Puttaiah, Raghunath

    2011-01-01

    Objectives: To study effects of various concentrations of hydrogen peroxide on mature waterline biofilms and in controlling planktonic (free-floating) organisms in simulated dental treatment water systems; and to study in vitro the effects of 2%, 3%, and 7% hydrogen peroxide on the removal of mature biofilms and inorganic compounds in dental waterlines. Methods: Four units of an automated dental unit water system simulation device was used for 12 weeks. All units were initially cleaned to control biofilms and inorganic deposits. H2O2 at concentrations of 1%, 2%, 3% was used weekly for periodic cleaning in three treatment group units (units 1, 2 & 3), with 0.05%, 0.15% and 0.25% H2O2 in municipal water used as irrigant respectively. The control unit (unit 4) did not have weekly cleanings and used municipal water as irrigant. Laser Scanning Confocal Microscopy and Scanning Electron Microscopy were used to study deposits on lines, and weekly heterotrophic plate counts done to study effluent water contamination. A 24 hour in vitro challenge test with 7%, 3% and 2% H2O2 on mature biofilms was conducted using harvested waterlines to study biofilm and inorganic deposit removal. Results: Heterotrophic plate counts of effluent water showed that the control unit reached contamination levels in excess of 400,000 CFU/mL while all treatment units showed contamination levels <500 CFU/mL through most of the 12 weeks. All treatment units showed varying levels of biofilm and inorganic deposit control in this short 12 week study. The in vitro challenge test showed although there was biofilm control, there was no eradication even when 7% H2O2 was used for 24 hours. Conclusions: 2% H2O2 used as a periodic cleaner, and diluted to 0.05% in municipal water for irrigation was beneficial in controlling biofilm and planktonic contamination in dental unit water systems. However, to remove well established biofilms, it may take more than 2 months when initial and multiple periodic cleanings are performed using H2O2. PMID:21228956

  1. Wireless, relative-motion computer input device

    DOEpatents

    Holzrichter, John F.; Rosenbury, Erwin T.

    2004-05-18

    The present invention provides a system for controlling a computer display in a workspace using an input unit/output unit. A train of EM waves are sent out to flood the workspace. EM waves are reflected from the input unit/output unit. A relative distance moved information signal is created using the EM waves that are reflected from the input unit/output unit. Algorithms are used to convert the relative distance moved information signal to a display signal. The computer display is controlled in response to the display signal.

  2. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  3. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  4. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  5. 40 CFR 1042.125 - Maintenance instructions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES AND VESSELS Emission... converters, electronic control units, particulate traps, trap oxidizers, components related to particulate..., electronic control units, particulate traps, trap oxidizers, components related to particulate traps and trap...

  6. Design description of a microprocessor based Engine Monitoring and Control unit (EMAC) for small turboshaft

    NASA Technical Reports Server (NTRS)

    Baez, A. N.

    1985-01-01

    Research programs have demonstrated that digital electronic controls are more suitable for advanced aircraft/rotorcraft turbine engine systems than hydromechanical controls. Commercially available microprocessors are believed to have the speed and computational capability required for implementing advanced digital control algorithms. Thus, it is desirable to demonstrate that off-the-shelf microprocessors are indeed capable of performing real time control of advanced gas turbine engines. The engine monitoring and control (EMAC) unit was designed and fabricated specifically to meet the requirements of an advanced gas turbine engine control system. The EMAC unit is fully operational in the Army/NASA small turboshaft engine digital research program.

  7. 26 CFR 1.957-2 - Controlled foreign corporation deriving income from insurance of United States risks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... from insurance of United States risks. 1.957-2 Section 1.957-2 Internal Revenue INTERNAL REVENUE... Corporations § 1.957-2 Controlled foreign corporation deriving income from insurance of United States risks. (a... States risks under § 1.953-1, the term “controlled foreign corporation” means any foreign corporation of...

  8. Engine Tune-up Service. Unit 6: Emission Control Systems. Student Guide. Automotive Mechanics Curriculum.

    ERIC Educational Resources Information Center

    Bacon, E. Miles

    This student guide is for Unit 6, Emission Control Systems, in the Engine Tune-Up Service portion of the Automotive Mechanics Curriculum. It deals with inspecting, testing, and servicing an emission control system. A companion review exercise book and posttests are available separately as CE 031 221-222. An introduction tells how this unit fits…

  9. Unit undergoes controls upgrade to meet cycling needs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weston, B.; Tinkham, R.; Chloupek, J.

    1994-04-01

    New England Electric System's Brayton Point Unit 3, Somerset, Mass, along with many other units in the US, has been forced into cycling operation on a much more frequent basis than was intended when the original controls were installed. Low-load operation and lengthy startup times also had to be addressed. An integrated control and monitoring system installed at Unit 3 to handle the boiler/turbine controls, burner management, and equipment monitoring functions. New strategies, particularly with the startup valves, were implemented to provide faster, safer, and more economical startups. The retrofit has been a success, with marked improvement in both startupmore » and operation.« less

  10. The control unit of the near infrared spectrograph of the Euclid space mission: detailed design

    NASA Astrophysics Data System (ADS)

    Toledo-Moreo, Rafael; Colodro-Conde, Carlos; Gómez-Sáenz-de-Tejada, Jaime; Pérez-Lizán, David; Díaz-García, José Javier; Tubío-Araujo, Óscar; Raichs, Cayetano; Catalán, Jordi; Rebolo-López, Rafael

    2016-07-01

    The Near Infrared Spectrograph and Photometer (NISP) is one of the instruments on board the ESA EUCLID mission. The Universidad Politécnica de Cartagena and Instituto de Astrofísica de Canarias are responsible of the Instrument Control Unit of the NISP (NI-ICU) in the Euclid Consortium. The NI-ICU hardware is developed by CRISA (Airbus Defence and Space), and its main functions are: communication with the S/C and the Data Processing Unit, control of the Filter and Grism Wheels, control of the Calibration Unit and thermal control of the instrument. This paper presents the NI-ICU status of definition and design at the end of the detailed design phase.

  11. 75 FR 52948 - Agency Information Collection Request; 60-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-30

    .... Proposed Project: State Medicaid Fraud Control Units' Reports--OMB No. 0990-0162-Extension--Office of the... requirements in Title 19 of the Social Security Act at 1903 (q) and 42 CFR1007.15 and 1007.17, in accordance... Medicaid Fraud Control Units (Units). OIG uses the information received to assess and determine the Units...

  12. 75 FR 52948 - Agency Information Collection Request; 60-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-30

    .... Proposed Project: State Medicaid Fraud Control Units' Reports--OMB No. 0990-0162-Extension--Office of the... requirements in Title 19 of the Social Security Act at 1903(q) and 42 CFR 1007.15 and 1007.17, in accordance... Medicaid Fraud Control Units (Units). OIG uses the information received to assess and determine the Units...

  13. Relations between Municipal Water Use and Selected Meteorological Parameters and Drought Indices, East-Central and Northeast Florida

    USGS Publications Warehouse

    Murray, Louis C.

    2009-01-01

    Water-use data collected between 1992 and 2006 at eight municipal water-supply utilities in east-central and northeast Florida were analyzed to identify seasonal trends in use and to quantify monthly variations. Regression analyses were applied to identify significant correlations between water use and selected meteorological parameters and drought indices. Selected parameters and indices include precipitation (P), air temperature (T), potential evapotranspiration (PET), available water (P-PET), monthly changes in these parameters (Delta P, Delta T, Delta PET, Delta(P-PET), the Palmer Drought Severity Index (PDSI), and the Standardized Precipitation Index (SPI). Selected utilities include the City of Daytona Beach (Daytona), the City of Eustis (Eustis), Gainesville Regional Utilities (GRU), Jacksonville Electric Authority (JEA), Orange County Utilities (OCU), Orlando Utilities Commission (OUC), Seminole County Utilities (SCU), and the City of St. Augustine (St. Augustine). Water-use rates at these utilities in 2006 ranged from about 3.2 million gallons per day at Eustis to about 131 million gallons per day at JEA. Total water-use rates increased at all utilities throughout the 15-year period of record, ranging from about 4 percent at Daytona to greater than 200 percent at OCU and SCU. Metered rates, however, decreased at six of the eight utilities, ranging from about 2 percent at OCU and OUC to about 17 percent at Eustis. Decreases in metered rates occurred because the number of metered connections increased at a greater rate than did total water use, suggesting that factors other than just population growth may play important roles in water-use dynamics. Given the absence of a concurrent trend in precipitation, these decreases can likely be attributed to changes in non-climatic factors such as water-use type, usage of reclaimed water, water-use restrictions, demographics, and so forth. When averaged for the eight utilities, metered water-use rates depict a clear seasonal pattern in which rates were lowest in the winter and greatest in the late spring. Averaged water-use rates ranged from about 9 percent below the 15-year daily mean in January to about 11 percent above the daily mean in May. Water-use rates were found to be statistically correlated to meteorological parameters and drought indices, and to be influenced by system memory. Metered rates (in gallons per day per active metered connection) were consistently found to be influenced by P, T, PET, and P-PET and changes in these parameters that occurred in prior months. In the single-variant analyses, best correlations were obtained by fitting polynomial functions to plots of metered rates versus moving-averaged values of selected parameters (R2 values greater than 0.50 at three of eight sites). Overall, metered water-use rates were best correlated with the 3- to 4-month moving average of Delta T or Delta PET (R2 values up to 0.66), whereas the full suite of meteorological parameters was best correlated with metered rates at Daytona and least correlated with rates at St. Augustine. Similarly, metered rates were substantially better correlated with moving-averaged values of precipitation (significant at all eight sites) than with single (current) monthly values (significant at only three sites). Total and metered water-use rates were positively correlated with T, PET, Delta P, Delta T, and Delta PET, and negatively correlated with P, P-PET, Delta (P-PET), PDSI, and SPI. The drought indices were better correlated with total water-use rates than with metered rates, whereas metered rates were better correlated with meteorological parameters. Multivariant analyses produced fits of the data that explained a greater degree of the variance in metered rates than did the single-variant analyses. Adjusted R2 values for the 'best' models ranged from 0.79 at JEA to 0.29 at St. Augustine and exceeded 0.60 at five of eight sites. The amount of available water (P-PET) was the si

  14. Salinity Trends in the Upper Colorado River Basin Upstream From the Grand Valley Salinity Control Unit, Colorado, 1986-2003

    USGS Publications Warehouse

    Leib, Kenneth J.; Bauch, Nancy J.

    2008-01-01

    In 1974, the Colorado River Basin Salinity Control Act was passed into law. This law was enacted to address concerns regarding the salinity content of the Colorado River. The law authorized various construction projects in selected areas or 'units' of the Colorado River Basin intended to reduce the salinity load in the Colorado River. One such area was the Grand Valley Salinity Control Unit in western Colorado. The U. S. Geological Survey has done extensive studies and research in the Grand Valley Salinity Control Unit that provide information to aid the U.S. Bureau of Reclamation and the Natural Resources Conservation Service in determining where salinity-control work may provide the best results, and to what extent salinity-control work was effective in reducing salinity concentrations and loads in the Colorado River. Previous studies have indicated that salinity concentrations and loads have been decreasing downstream from the Grand Valley Salinity Control Unit, and that the decreases are likely the result of salinity control work in these areas. Several of these reports; however, also document decreasing salinity loads upstream from the Grand Valley Salinity Control Unit. This finding was important because only a small amount of salinity-control work was being done in areas upstream from the Grand Valley Salinity Control Unit at the time the findings were reported (late 1990?s). As a result of those previous findings, the U.S. Bureau of Reclamation entered into a cooperative agreement with the U.S. Geological Survey to investigate salinity trends in selected areas bracketing the Grand Valley Salinity Control Unit and regions upstream from the Grand Valley Salinity Control Unit. The results of the study indicate that salinity loads were decreasing upstream from the Grand Valley Salinity Control Unit from 1986 through 2003, but the rates of decrease have slowed during the last 10 years. The average rate of decrease in salinity load upstream from the Grand Valley Salinity Control Unit was 10,700 tons/year. This accounts for approximately 27 percent of the decrease observed downstream from the Grand Valley Salinity Control Unit. Salinity loads were decreasing at the fastest rate (6,950 tons/year) in Region 4, which drains an area between the Colorado River at Cameo, Colorado (station CAMEO) and Colorado River above Glenwood Springs, Colorado (station GLEN) streamflow-gaging stations. Trends in salinity concentration and streamflow were tested at station CAMEO to determine if salinity concentration, streamflow, or both are controlling salinity loads upstream from the Grand Valley Salinity Control Unit. Trend tests of individual ion concentrations were included as potential indicators of what sources (based on mineral composition) may be controlling trends in the upper Colorado. No significant trend was detected for streamflow from 1986 to 2003 at station CAMEO; however, a significant downward trend was detected for salinity concentration. The trend slope indicates that salinity concentration is decreasing at a median rate of about 3.54 milligrams per liter per year. Five major ions (calcium, magnesium, sodium, sulfate, and chloride) were tested for trends. The results indicate that processes within source areas with rock and soil types (or other unidentified sources) bearing calcium, sodium, and sulfate had the largest effect on the downward trend in salinity load upstream from station CAMEO. Downward trends in salinity load resulting from ground-water sources and/or land-use change were thought to be possible reasons for the observed decreases in salinity loads; however, the cause or causes of the decreasing salinity loads are not fully understood. A reduction in the amount of ground-water percolation from Region 4 (resulting from work done through Federal irrigation system improvement programs as well as privately funded irrigation system improvements) has helped reduce annual salinity load from Region 4 by approxima

  15. Tuning of PID controllers for boiler-turbine units.

    PubMed

    Tan, Wen; Liu, Jizhen; Fang, Fang; Chen, Yanqiao

    2004-10-01

    A simple two-by-two model for a boiler-turbine unit is demonstrated in this paper. The model can capture the essential dynamics of a unit. The design of a coordinated controller is discussed based on this model. A PID control structure is derived, and a tuning procedure is proposed. The examples show that the method is easy to apply and can achieve acceptable performance.

  16. 40 CFR 75.19 - Optional SO2, NOX, and CO2 emissions calculation for low mass emissions (LME) units.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...), manufacturer and model, and must have the same history of modifications (e.g., have the same controls installed... (or group of identical units) equipped with SCR (or SNCR) and uses dry low-NOX technology to control... with add-on NOX emission controls, and for units that use dry low-NOX technology, the owner or operator...

  17. MAS2-8 radar and digital control unit

    NASA Technical Reports Server (NTRS)

    Oberg, J. M.; Ulaby, F. T.

    1974-01-01

    The design of the MAS 2-8 (2 to 8 GHz microwave-active spectrometer), a ground-based sensor system, is presented. A major modification in 1974 to the MAS 2-8, that of a control subsystem to automate the data-taking operation, is the prime focus. The digital control unit automatically changes all system parameters except FM rate and records the return signal on paper tape. The overall system operation and a detailed discussion of the design and operation of the digital control unit are presented.

  18. Variable-Displacement Hydraulic Drive Unit

    NASA Technical Reports Server (NTRS)

    Lang, D. J.; Linton, D. J.; Markunas, A.

    1986-01-01

    Hydraulic power controlled through multiple feedback loops. In hydraulic drive unit, power closely matched to demand, thereby saving energy. Hydraulic flow to and from motor adjusted by motor-control valve connected to wobbler. Wobbler angle determines motor-control-valve position, which in turn determines motor displacement. Concept applicable to machine tools, aircraft controls, and marine controls.

  19. 22 CFR 120.29 - Missile Technology Control Regime.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Missile Technology Control Regime. 120.29... DEFINITIONS § 120.29 Missile Technology Control Regime. (a) For purposes of this subchapter, Missile Technology Control Regime (MTCR) means the policy statement between the United States, the United Kingdom...

  20. 40 CFR 1033.510 - Auxiliary power units.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...

  1. 40 CFR 1033.510 - Auxiliary power units.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...

  2. 40 CFR 1033.510 - Auxiliary power units.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...

  3. 40 CFR 1033.510 - Auxiliary power units.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...

  4. 40 CFR 1033.510 - Auxiliary power units.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...

  5. Oximeter reliability in a subzero environment.

    PubMed

    Macnab, A J; Smith, M; Phillips, N; Smart, P

    1996-11-01

    Pulse oximeters optimize care in the pre-hospital setting. As British Columbia ambulance teams often provide care in subzero temperatures, we conducted a study to determine the reliability of 3 commercially-available portable oximeters in a subzero environment. We hypothesized that there is no significant difference between SaO2 readings obtained using a pulse oximeter at room temperature and a pulse oximeter operating at sub-zero temperatures. Subjects were stable normothermic children in intensive care on Hewlett Packard monitors (control unit) at room temperature. The test units were packed in dry ice in an insulated bin (temperature - 15 degrees C to -30 degrees C) and their sensors placed on the subjects, contralateral to the control sensors. Data were collected simultaneously from test and control units immediately following validation of control unit values by co-oximetry (blood gas). No data were unacceptable. Two units (Propaq 106EC and Nonin 8500N) functioned well to < -15 degrees C, providing data comparable to those obtained from the control unit (p < 0.001). The Siemens Micro O2 did not function at the temperatures tested. Monitor users who require equipment to function in subzero environments (military, Coast Guard, Mountain Rescue) should ensure that function is reliable, and could test units using this method.

  6. 75 FR 17839 - National Cancer Control Month, 2010

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... Cancer Control Month, 2010 By the President of the United States of America A Proclamation Cancer is.... During National Cancer Control Month, let us renew our commitment to combat this disease by raising... as ``Cancer Control Month.'' NOW, THEREFORE, I, BARACK OBAMA, President of the United States of...

  7. 12 CFR 243.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the United States; (ii) Controls a bank in the United States; or (iii) Controls an Edge corporation... Board and for which such determination is still in effect. (o) Rapid and orderly resolution means a... failure of the covered company would have serious adverse effects on financial stability in the United...

  8. 12 CFR 243.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the United States; (ii) Controls a bank in the United States; or (iii) Controls an Edge corporation... Board and for which such determination is still in effect. (o) Rapid and orderly resolution means a... failure of the covered company would have serious adverse effects on financial stability in the United...

  9. 12 CFR 243.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the United States; (ii) Controls a bank in the United States; or (iii) Controls an Edge corporation... Board and for which such determination is still in effect. (o) Rapid and orderly resolution means a... failure of the covered company would have serious adverse effects on financial stability in the United...

  10. 12 CFR 381.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the United States; (ii) Controls a bank in the United States; or (iii) Controls an Edge corporation... Board and for which such determination is still in effect. (o) Rapid and orderly resolution means a... failure of the covered company would have serious adverse effects on financial stability in the United...

  11. 12 CFR 381.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the United States; (ii) Controls a bank in the United States; or (iii) Controls an Edge corporation... Board and for which such determination is still in effect. (o) Rapid and orderly resolution means a... failure of the covered company would have serious adverse effects on financial stability in the United...

  12. RF control hardware design for CYCIAE-100 cyclotron

    NASA Astrophysics Data System (ADS)

    Yin, Zhiguo; Fu, Xiaoliang; Ji, Bin; Zhao, Zhenlu; Zhang, Tianjue; Li, Pengzhan; Wei, Junyi; Xing, Jiansheng; Wang, Chuan

    2015-11-01

    The Beijing Radioactive Ion-beam Facility project is being constructed by BRIF division of China Institute of Atomic Energy. In this project, a 100 MeV high intensity compact proton cyclotron is built for multiple applications. The first successful beam extraction of CYCIAE-100 cyclotron was done in the middle of 2014. The extracted proton beam energy is 100 MeV and the beam current is more than 20 μA. The RF system of the CYCIAE-100 cyclotron includes two half-wavelength cavities, two 100 kW tetrode amplifiers and power transmission line systems (all above are independent from each other) and two sets of Low Level RF control crates. Each set of LLRF control includes an amplitude control unit, a tuning control unit, a phase control unit, a local Digital Signal Process control unit and an Advanced RISC Machines based EPICS IOC unit. These two identical LLRF control crates share one common reference clock and take advantages of modern digital technologies (e.g. DSP and Direct Digital Synthesizer) to achieve closed loop voltage and phase regulations of the dee-voltage. In the beam commission, the measured dee-voltage stability of RF system is better than 0.1% and phase stability is better than 0.03°. The hardware design of the LLRF system will be reviewed in this paper.

  13. Design of a Microprogram Control Unit with Concurrent Error Detection.

    DTIC Science & Technology

    1984-08-01

    I fxoot Office of Naval Research N/A N00039-80-C-0556 ta. ADDRESS (City. St.. and ZIP Cod 10. SOURCE OF FUNOING N0. -PROGRAM PROJECT TASK WORK UNIT...However, the CED concept is mainly applied to various codes data transmission, and simple functional units, such as arithmetic units. Little work has...been done in the control unit area. Previous work is primarily in the use of clanical self-checking circuits, using bit slicin& parity, and m-out-of-n

  14. Information management system breadboard data acquisition and control system.

    NASA Technical Reports Server (NTRS)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  15. The trend of digital control system design for nuclear power plants in Korea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, S. H.; Jung, H. Y.; Yang, C. Y.

    2006-07-01

    Currently there are 20 nuclear power plants (NPPs) in operation, and 6 more units are under construction in Korea. The control systems of those NPPs have also been developed together with the technology advancement. Control systems started with On-Off control using the relay logic, had been evolved into Solid-State logic using TTL ICs, and applied with the micro-processors since the Yonggwang NPP Units 3 and 4 which started its construction in 1989. Multiplexers are also installed at the local plant areas to collect field input and to send output signals while communicating with the controllers located in the system cabinetsmore » near the main control room in order to reduce the field wiring cables. The design of the digital control system technology for the NPPs in Korea has been optimized to maximize the operability as well as the safety through the design, construction, start-up and operation experiences. Both Shin-Kori Units 1 and 2 and Shin-Wolsong Units 1 and 2 NPP projects under construction are being progressed at the same time. Digital Plant Control Systems of these projects have adopted multi-loop controllers, redundant loop configuration, and soft control system for the radwaste system. Programmable Logic Controller (PLC) and Distributed Control System (DCS) are applied with soft control system in Shin-Kori Units 3 and 4. This paper describes the evolvement of control system at the NPPs in Korea and the experience and design improvement through the observation of the latest failure of the digital control system. In addition, design concept and its trend of the digital control system being applied to the NPP in Korea are introduced. (authors)« less

  16. Solar heating system final design package

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The system is composed of a warm air collector, a logic control unit and a universal switching and transport unit. The collector was originally conceived and designed as an integrated roof/wall system and therefore provides a dual function in the structure. The collector serves both as a solar energy conversion system and as a structural weather resistant skin. The control unit provides totally automatic control over the operation of the system. It receives input data from sensor probes in collectors, storage and living space. The logic was designed so as to make maximum use of solar energy and minimize use of conventional energy. The transport and switching unit is a high-efficiency air-handling system equipped with gear motor valves that respond to outputs from the control system. The fan unit was designed for maximum durability and efficiency in operation, and has permanently lubricated ball bearings and excellent air-handling efficiency.

  17. System for loading executable code into volatile memory in a downhole tool

    DOEpatents

    Hall, David R.; Bartholomew, David B.; Johnson, Monte L.

    2007-09-25

    A system for loading an executable code into volatile memory in a downhole tool string component comprises a surface control unit comprising executable code. An integrated downhole network comprises data transmission elements in communication with the surface control unit and the volatile memory. The executable code, stored in the surface control unit, is not permanently stored in the downhole tool string component. In a preferred embodiment of the present invention, the downhole tool string component comprises boot memory. In another embodiment, the executable code is an operating system executable code. Preferably, the volatile memory comprises random access memory (RAM). A method for loading executable code to volatile memory in a downhole tool string component comprises sending the code from the surface control unit to a processor in the downhole tool string component over the network. A central processing unit writes the executable code in the volatile memory.

  18. Orderly recruitment of motor units under optical control in vivo.

    PubMed

    Llewellyn, Michael E; Thompson, Kimberly R; Deisseroth, Karl; Delp, Scott L

    2010-10-01

    A drawback of electrical stimulation for muscle control is that large, fatigable motor units are preferentially recruited before smaller motor units by the lowest-intensity electrical cuff stimulation. This phenomenon limits therapeutic applications because it is precisely the opposite of the normal physiological (orderly) recruitment pattern; therefore, a mechanism to achieve orderly recruitment has been a long-sought goal in physiology, medicine and engineering. Here we demonstrate a technology for reliable orderly recruitment in vivo. We find that under optical control with microbial opsins, recruitment of motor units proceeds in the physiological recruitment sequence, as indicated by multiple independent measures of motor unit recruitment including conduction latency, contraction and relaxation times, stimulation threshold and fatigue. As a result, we observed enhanced performance and reduced fatigue in vivo. These findings point to an unanticipated new modality of neural control with broad implications for nervous system and neuromuscular physiology, disease research and therapeutic innovation.

  19. An extensible, low-cost drifter control unit

    NASA Astrophysics Data System (ADS)

    Giudici, Andrea; Torsvik, Tomas; Soomere, Tarmo

    2017-04-01

    We introduce an extensible, low-cost drifter control unit, which is developed for use with surface drifters that are deployed in inland water bodies or near-coast regions. The control unit is custom-built on top of a small footprint micro controller. It makes use of a GPS receiver for position tracking, a GSM radio for data transmission, and two sensor buses to handle analog and digital data measured by an array of external sensors. A cloud-based data collection platform receives and stores the data transmitted over GPRS from the drifter. The control unit was found to perform satisfactorily in operational testing, providing data at sub-Hz frequency for position and temperature during extended time. Test deployments revealed some issues related to power consumption spikes. Even though the unit is fully functional in the present form and shows, on average, low energy consumption , battery packs with relatively large maximum output power are required to ensure its operation within prolonged periods of time. We expect that a further development of the power supply unit together with a careful de-synchronization scheme of sensors' operation would smooth those peaks without any loss of the quality of recorded information.

  20. Communicating with residential electrical devices via a vehicle telematics unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roth, Rebecca C.; Pebbles, Paul H.

    A method of communicating with residential electrical devices using a vehicle telematics unit includes receiving information identifying a residential electrical device to control; displaying in a vehicle one or more controlled features of the identified residential electrical device; receiving from a vehicle occupant a selection of the displayed controlled features of the residential electrical device; sending an instruction from the vehicle telematics unit to the residential electrical device via a wireless carrier system in response to the received selection; and controlling the residential electrical device using the sent instruction.

  1. 17. ROSS POWERHOUSE: BUTTERFLY VALVE CONTROLS FOR UNIT 43. THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. ROSS POWERHOUSE: BUTTERFLY VALVE CONTROLS FOR UNIT 43. THE BUTTERFLY VALVE LOCK INDICATES THE BUTTERFLY VALVE IS CLOSED AS UNIT 43 WAS SHUT DOWN FOR REPAIRS, 1989. - Skagit Power Development, Ross Powerhouse, On Skagit River, 10.7 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  2. Hardware math for the 6502 microprocessor

    NASA Technical Reports Server (NTRS)

    Kissel, R.; Currie, J.

    1985-01-01

    A floating-point arithmetic unit is described which is being used in the Ground Facility of Large Space Structures Control Verification (GF/LSSCV). The experiment uses two complete inertial measurement units and a set of three gimbal torquers in a closed loop to control the structural vibrations in a flexible test article (beam). A 6502 (8-bit) microprocessor controls four AMD 9511A floating-point arithmetic units to do all the computation in 20 milliseconds.

  3. System and Method for High-Speed Data Recording

    NASA Technical Reports Server (NTRS)

    Taveniku, Mikael B. (Inventor)

    2017-01-01

    A system and method for high speed data recording includes a control computer and a disk pack unit. The disk pack is provided within a shell that provides handling and protection for the disk packs. The disk pack unit provides cooling of the disks and connection for power and disk signaling. A standard connection is provided between the control computer and the disk pack unit. The disk pack units are self sufficient and able to connect to any computer. Multiple disk packs are connected simultaneously to the system, so that one disk pack can be active while one or more disk packs are inactive. To control for power surges, the power to each disk pack is controlled programmatically for the group of disks in a disk pack.

  4. Hierarchical control of motor units in voluntary contractions.

    PubMed

    De Luca, Carlo J; Contessa, Paola

    2012-01-01

    For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The "firing rate spectrum" presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units-both characteristics being well suited for generating and sustaining force during the fight-or-flight response.

  5. OCDR guided laser ablation device

    DOEpatents

    Dasilva, Luiz B.; Colston, Jr., Bill W.; James, Dale L.

    2002-01-01

    A guided laser ablation device. The device includes a mulitmode laser ablation fiber that is surrounded by one or more single mode optical fibers that are used to image in the vicinity of the laser ablation area to prevent tissue damage. The laser ablation device is combined with an optical coherence domain reflectometry (OCDR) unit and with a control unit which initializes the OCDR unit and a high power laser of the ablation device. Data from the OCDR unit is analyzed by the control unit and used to control the high power laser. The OCDR images up to about 3 mm ahead of the ablation surface to enable a user to see sensitive tissue such as a nerve or artery before damaging it by the laser.

  6. Contribution from motor unit firing adaptations and muscle co-activation during fatigue.

    PubMed

    Contessa, Paola; Letizi, John; De Luca, Gianluca; Kline, Joshua C

    2018-03-14

    The control of motor unit firing behavior during fatigue is still debated in the literature. Most studies agree that the central nervous system increases the excitation to the motoneuron pool to compensate for decreased force contributions of individual motor units and sustain muscle force output during fatigue. However, some studies claim that motor units may decrease their firing rates despite increased excitation, contradicting the direct relationship between firing rates and excitation that governs the voluntary control of motor units. To investigate whether the control of motor units in fact changes with fatigue, we measured motor unit firing behavior during repeated contractions of the first dorsal interosseous (FDI) muscle while concurrently monitoring the activation of surrounding muscles - including the flexor carpi radialis, extensor carpi radialis, and pronator teres. Across all subjects, we observed an overall increase in FDI activation and motor unit firing rates by the end of the fatigue task. However, in some subjects we observed increases in FDI activation and motor unit firing rates only during the initial phase of the fatigue task, followed by subsequent decreases during the late phase of the fatigue task while the co-activation of surrounding muscles increased. These findings indicate that the strategy for sustaining force output may occasionally change leading to increases in the relative activation of surrounding muscles while the excitation to the fatiguing muscle decreases. Importantly, irrespective of changes in the strategy for sustaining force output, the control properties regulating motor unit firing behavior remain unchanged during fatigue.

  7. Knowledge Gaps Impacting the Development of Bovine Viral Diarrhea Virus Control Programs in the United States

    USDA-ARS?s Scientific Manuscript database

    This paper identifies knowledge gaps that impact on the design of programs to control and or eradicate bovine viral diarrhea viruses (BVDV) in the United States. Currently there are several voluntary regional BVDV control programs in place. These control programs are aimed at the removal of animals ...

  8. Development of a Practical Broadband Active Vibration Control System

    NASA Technical Reports Server (NTRS)

    Schiller, Noah H.; Perey, Daniel F.; Cabell, Randolph H.

    2011-01-01

    The goal of this work is to develop robust, lightweight, and low-power control units that can be used to suppress structural vibration in flexible aerospace structures. In particular, this paper focuses on active damping, which is implemented using compact decentralized control units distributed over the structure. Each control unit consists of a diamond-shaped piezoelectric patch actuator, three miniature accelerometers, and analog electronics. The responses from the accelerometers are added together and then integrated to give a signal proportional to velocity. The signal is then inverted, amplified, and applied to the actuator, which generates a control force that is out of phase with the measured velocity. This paper describes the development of the control system, including a detailed description of the control and power electronics. The paper also presents experimental results acquired on a Plexiglas window blank. Five identical control units installed around the perimeter of the window achieved 10 dB peak reductions and a 2.4 dB integrated reduction of the spatially averaged velocity of the window between 500 and 3000 Hz.

  9. Controlling Energy Radiations of Electromagnetic Waves via Frequency Coding Metamaterials.

    PubMed

    Wu, Haotian; Liu, Shuo; Wan, Xiang; Zhang, Lei; Wang, Dan; Li, Lianlin; Cui, Tie Jun

    2017-09-01

    Metamaterials are artificial structures composed of subwavelength unit cells to control electromagnetic (EM) waves. The spatial coding representation of metamaterial has the ability to describe the material in a digital way. The spatial coding metamaterials are typically constructed by unit cells that have similar shapes with fixed functionality. Here, the concept of frequency coding metamaterial is proposed, which achieves different controls of EM energy radiations with a fixed spatial coding pattern when the frequency changes. In this case, not only different phase responses of the unit cells are considered, but also different phase sensitivities are also required. Due to different frequency sensitivities of unit cells, two units with the same phase response at the initial frequency may have different phase responses at higher frequency. To describe the frequency coding property of unit cell, digitalized frequency sensitivity is proposed, in which the units are encoded with digits "0" and "1" to represent the low and high phase sensitivities, respectively. By this merit, two degrees of freedom, spatial coding and frequency coding, are obtained to control the EM energy radiations by a new class of frequency-spatial coding metamaterials. The above concepts and physical phenomena are confirmed by numerical simulations and experiments.

  10. 21 CFR 211.160 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... drafted by the appropriate organizational unit and reviewed and approved by the quality control unit. The...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Laboratory Controls § 211.160... procedures, or other laboratory control mechanisms required by this subpart, including any change in such...

  11. 31 CFR 545.527 - Diplomatic pouches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TALIBAN (AFGHANISTAN) SANCTIONS REGULATIONS Licenses... with the importation into the United States from the territory of Afghanistan controlled by the Taliban, or the exportation from the United States to the territory of Afghanistan controlled by the Taliban...

  12. 40 CFR 1039.125 - What maintenance instructions must I give to buyers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... maintaining and using the engine, including the emission-control system. The maintenance instructions also...,000 hours: Fuel injectors, turbochargers, catalytic converters, electronic control units, EGR systems..., catalytic converters, electronic control units, EGR systems (including related components, but excluding...

  13. 40 CFR 1039.125 - What maintenance instructions must I give to buyers?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... maintaining and using the engine, including the emission-control system. The maintenance instructions also...,000 hours: Fuel injectors, turbochargers, catalytic converters, electronic control units, EGR systems..., catalytic converters, electronic control units, EGR systems (including related components, but excluding...

  14. 40 CFR 1039.125 - What maintenance instructions must I give to buyers?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... maintaining and using the engine, including the emission-control system. The maintenance instructions also...,000 hours: Fuel injectors, turbochargers, catalytic converters, electronic control units, EGR systems..., catalytic converters, electronic control units, EGR systems (including related components, but excluding...

  15. 40 CFR 1039.125 - What maintenance instructions must I give to buyers?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... maintaining and using the engine, including the emission-control system. The maintenance instructions also...,000 hours: Fuel injectors, turbochargers, catalytic converters, electronic control units, EGR systems..., catalytic converters, electronic control units, EGR systems (including related components, but excluding...

  16. Maintenance of Occupational Control: The Case of Professions.

    ERIC Educational Resources Information Center

    Child, John; Fulk, Janet

    1982-01-01

    Contemporary conditions relevant to the maintenance of occupational control are examined for five professions (accounting, architecture, civil engineering, law, and medicine) in the United Kingdom and the United States as an impetus for the analysis of control by occupations in general. (Author/CT)

  17. Treatment of severe insulin resistance in pregnancy with 500 units per milliliter of concentrated insulin.

    PubMed

    Mendez-Figueroa, Hector; Maggio, Lindsay; Dahlke, Joshua D; Daley, Julie; Lopes, Vrishali V; Coustan, Donald R; Rouse, Dwight J

    2013-07-01

    To evaluate glycemic control and pregnancy outcomes among pregnant women with severe insulin resistance treated with 500 units/mL concentrated insulin. Retrospective analysis of gravid women with severe insulin resistance (need for greater than 100 units of insulin per injection or greater than 200 units/d) treated with either 500 units/mL concentrated insulin or conventional insulin therapy. We performed a two-part analysis: 1) between gravid women treated with and without 500 units/mL concentrated insulin; and 2) among gravid women treated with 500 units/mL concentrated insulin, comparing glycemic control before and after its initiation. Seventy-three pregnant women with severe insulin resistance were treated with 500 units/mL concentrated insulin and 78 with conventional insulin regimens. Patients treated with 500 units/mL concentrated insulin were older and more likely to have type 2 diabetes mellitus. Average body mass index was comparable between both groups (38.6 compared with 40.4, P=.11) as were obstetric and perinatal outcomes and glycemic control during the last week of gestation. Within the 500 units/mL concentrated insulin cohort, after initiation of this medication, fasting and postprandial blood glucose concentrations improved. However, the rates of blood glucose values less than 60 mg/dL and less than 50 mg/dL were higher in the 500 units/mL concentrated insulin group after initiation than before, 4.8% compared with 2.0% (P<.01) and 2.0% compared with 0.7% (P<.01), respectively. The use of 500 units/mL concentrated insulin in severely obese insulin-resistant pregnant women confers similar glycemic control compared with traditional insulin regimens but may increase the risk of hypoglycemia. II.

  18. Supervisory Control Information Management Research (SCIMR) Studies: Determination of Efficiency for a Variety of Input Control Equipment (DEVICE)

    DTIC Science & Technology

    2010-08-01

    Belkin n52te, the Saitek Cyborg Command Unit, the Wacom Bamboo Fun with stylus, the Wacom Bamboo Fun with touch, and the Xbox 360 controller...4 4 Saitek Cyborg Command Unit function mapping ....................................... 4 iv 5 Wacom Bamboo Fun with stylus and touch...versus Belkin n52te by task . 30 B-2 Participants’ preferences for standard mouse versus Saitek Cyborg Command Unit by task

  19. Comparison of JP-8 Sprays from a Hydraulically Actuated Electronically Controlled Unit Injector and a Common Rail Injector

    DTIC Science & Technology

    2015-10-01

    acquired of a calibration plate to provide scaling for the injector orifices. The determined scaling factor for the images was 0.3 µm/pixel. A circle...Controlled Unit Injector and a Common Rail Injector by Matthew Kurman, Michael Tess, Luis Bravo, Chol-Bum Kweon, and Craig Hershey Reprinted...Comparison of JP-8 Sprays from a Hydraulically Actuated Electronically Controlled Unit Injector and a Common Rail Injector by Matthew Kurman

  20. 40 CFR 97.621 - Recordation of TR SO2 Group 1 allowance allocations and auction results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... allocated to the TR SO2 Group 1 units at the source in accordance with § 97.611(a) for the control period in... allocated to the TR SO2 Group 1 units at the source in accordance with § 97.611(a) for the control period in... SO2 Group 1 units at the source in accordance with § 97.611(a) for the control period in 2013. (c) By...

  1. 40 CFR 97.721 - Recordation of TR SO2 Group 2 allowance allocations and auction results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... allocated to the TR SO2 Group 2 units at the source in accordance with § 97.711(a) for the control period in... allocated to the TR SO2 Group 2 units at the source in accordance with § 97.711(a) for the control period in... SO2 Group 2 units at the source in accordance with § 97.711(a) for the control period in 2013. (c) By...

  2. 42 CFR 455.21 - Cooperation with State Medicaid fraud control units.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... subchapter. In using this information, the unit must protect the privacy rights of beneficiaries; and (3) On... 42 Public Health 4 2014-10-01 2014-10-01 false Cooperation with State Medicaid fraud control units. 455.21 Section 455.21 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND...

  3. 75 FR 66101 - Agency Information Collection Request. 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-27

    ... Medicaid Fraud Control Units' Reports--OMB No. 0990-0162-Extension--Office of Inspector General (OIG... collection of information to specifically comply with the requirements in Title 19 of the Social Security Act... Inspector General (OIG) by the fifty established State Medicaid Fraud Control Units (Units). OIG uses the...

  4. 77 FR 4588 - Incapital LLC and Incapital Unit Trust; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ... sales charge. If such a market is not maintained at any time for any Series, holders of the Units... future unit investment trusts (collectively, with the Incapital Trust, the ``Trusts'') and series of the Trusts (``Series'') that are sponsored by Incapital or any entity controlling, controlled by or under...

  5. Modification and testing of an engine and fuel control system for a hydrogen fuelled gas turbine

    NASA Astrophysics Data System (ADS)

    Funke, H. H.-W.; Börner, S.; Hendrick, P.; Recker, E.

    2011-10-01

    The control of pollutant emissions has become more and more important by the development of new gas turbines. The use of hydrogen produced by renewable energy sources could be an alternative. Besides the reduction of NOx emissions emerged during the combustion process, another major question is how a hydrogen fuelled gas turbine including the metering unit can be controlled and operated. This paper presents a first insight in modifications on an Auxiliary Power Unit (APU) GTCP 36300 for using gaseous hydrogen as a gas turbine fuel. For safe operation with hydrogen, the metering of hydrogen has to be fast, precise, and secure. So, the quality of the metering unit's control loop has an important influence on this topic. The paper documents the empiric determination of the proportional integral derivative (PID) control parameters for the metering unit.

  6. Integrated optics reflectometer

    DOEpatents

    Couch, Philip R; Murphy, Kent A.; Gunther, Michael F; Gause, Charles B

    2017-01-31

    An apparatus includes a laser source configured to output laser light at a target frequency, and a measurement unit configured to measure a deviation between an actual frequency outputted by the laser source at a current period of time and the target frequency of the laser source. The apparatus includes a feedback control unit configured to, based on the measured deviation between the actual and target frequencies, control the laser source to maintain a constant frequency of laser output from the laser source so that the frequency of laser light transmitted from the laser source is adjusted to the target frequency. The feedback control unit can control the laser source to maintain a linear rate of change in the frequency of its laser light output, and compensate for characteristics of the measurement unit utilized for frequency measurement. A method is provided for performing the feedback control of the laser source.

  7. Effects of iodine in microbial control of dental treatment water.

    PubMed

    Puttaiah, Raghunath; Seibert, Jeff; Spears, Robert

    2011-05-01

    To determine the effects of low levels of iodine constantly present in the dental unit water system on microbial control of dental treatment water and biofilm control. This study used a dental unit water system simulator with eight dental unit waterline systems built to scale and function, each controlled via computer. Each of the eight units was operated independently, four units supplied with self-contained water reservoirs and four units supplied with municipal water. Four units were precleaned to remove biofilm buildup. The study had a well-balanced design with equal representation (variables) of presence/absence of biofilms, selfcontained reservoirs for introduction of treatment water, source water directly connected to municipal water source and iodinated cartridges within the self-contained reservoirs and between municipal water and dental unit. Point-of-use iodinated resin cartridges (IRC) were retrofitted proximal to handpiece and air/ water syringe tip lines in four units, and iodinated resin water cartridges (IRSWC) were fitted to the other four units at the source water output. Heterotrophic plate counts were performed at baseline and twice weekly for a period of 6 weeks. One representative waterline sample was taken from each group at baseline and end-of-study to analyze changes in biofilm status using scanning electron microscopy. Waterlines not previously contaminated with biofilms did not show organization of biofilm matrix in units equipped with IRSWC. Constantly present low levels of iodine, demonstrated some disruption of biofilms in waterlines already contaminated with mature biofilms. All groups showed contamination levels < 500 cfu/ml (colony forming units per milliliter) consistent with the CDC and ADA guidelines. In this 6 weeks study, IRSWC equipped waterlines showed disruption of established biofilms, controlled formation of new biofilms in clean lines and rendered the dental treatment water < 500 cfu/ml. Point-of-use iodinated resin cartridges were also effective in controlling contamination in the dental treatment water. Dental unit water systems that are in use get contaminated with microbes and biofilms in weeks of being put into use. These biofilms contaminate the treatment water thereby putting patients and staff at risk of infection by predominantly gram-negative microbes. Biofilms in the water systems must be cleaned periodically with a strong decontaminant and the dental treatment source water needs to be modified with a low-grade antimicrobial that can preserve the water quality yet safe to humans. In this translational research study, we evaluate the effects of elemental iodine dissolved in water flowing through an iodine containing cartridge in controlling biofilm and dental treatment water contamination using a dental unit water system simulator, prior to clinical utilization.

  8. Hard X-ray Sources for the Mexican Synchrotron Project

    NASA Astrophysics Data System (ADS)

    Reyes-Herrera, Juan

    2016-10-01

    One of the principal tasks for the design of the Mexican synchrotron was to define the storage ring energy. The main criteria for choosing the energy come from studying the electromagnetic spectrum that can be obtained from the synchrotron, because the energy range of the spectrum that can be obtained will determine the applications available to the users of the future light source. Since there is a public demand of hard X-rays for the experiments in the synchrotron community users from Mexico, in this work we studied the emission spectra from some hard X-ray sources which could be the best options for the parameters of the present Mexican synchrotron design. The calculations of the flux and the brightness for one Bending Magnet and four Insertion Devices are presented; specifically, for a Superconducting Bending Magnet (SBM), a Superconducting Wiggler (SCW), an In Vacuum Short Period Undulator (IV-SPU), a Superconducting Undulator (SCU) and for a Cryogenic Permanent Magnet Undulator (CPMU). Two commonly available synchrotron radiation programs were used for the computation (XOP and SRW). From the results, it can be concluded that the particle beam energy from the current design is enough to have one or more sources of hard X-rays. Furthermore, a wide range of hard X-ray region can be covered by the analyzed sources, and the choice of each type should be based on the specific characteristics of the X-ray beam to perform the experiments at the involved beamline. This work was done within the project Fomix Conacyt-Morelos ”Plan Estrategico para la construccion y operación de un Sincrotron en Morelos” (224392).

  9. Reactions of monodithiolene tungsten(VI) sulfido complexes with copper(I) in relation to the structure of the active site of carbon monoxide dehydrogenase.

    PubMed

    Groysman, Stanislav; Majumdar, Amit; Zheng, Shao-Liang; Holm, R H

    2010-02-01

    Reactions directed at the synthesis of structural analogues of the active site of molybdenum-containing carbon monoxide dehydrogenase have been investigated utilizing [WO(2)S(bdt)](2-) (1) and [WOS(2)(bdt)](2-) (2) and sterically hindered [Cu(R)L] or [Cu(SSiR'(3))(2)](-) as reactants. All successful reactions of 2 afford the binuclear W(VI)/Cu(I) products [WO(bdt)(mu(2)-S)(2)Cu(L)](2-/-) with L = carbene (3), Ar*S (4), Ar* (7), SSiR(3) (R = Ph (5), Pr(i) (6)). Similarly, [W(bdt)(OSiPh(3))S(2)](-) leads to [W(bdt)(OSiPh(3))(mu(2)-S)(2)Cu(SAr*)](-) (8). These complexes, with apical oxo and basal dithiolato and sulfido coordination (excluding 8), terminal thiolate ligation at Cu(I) (4-6, 8), and W-(mu(2)-S)-Cu bridging, bear a structural resemblance to the enzyme site. Differences include two bridges instead of one and the absence of basal oxo/hydroxo ligation. Complex 8 differs from the others by utilizing apical and basal sulfido ligands in bridge formation. Related reaction systems based on 1 gave 4 in small yield or product mixtures in which the desired monobridged complex [WO(2)(bdt)(mu(2)-S)Cu(R)](2-) was not detected. Mass spectrometric analysis of the reaction system with L = carbene suggests that any monobridged species forms may converted to the dibridged form by disproportionation. In these experiments, the use of W(VI) preserves the structural integrity of Mo(VI), whose analogues of 1 and 2 have not been isolated. (Ar* = 2,6-bis(2,4,6-triisopropylphenyl)phenyl, bdt = benzene-1,2-dithiolate(2-)).

  10. Biochemical and Parasitological Studies on the Effect of hUCB-Selected CD34+ Progenitor/Stem Cells in Mice Infected with Schistosoma mansoni

    PubMed Central

    Abou-Zied, Akram M.; Soliman, Rasha H.; Hefila, Shorouk M.; Imam, Samir A.

    2014-01-01

    Background and Objectives: Placenta and blood that remained in the umbilical cord is routinely available as a discarded tissue after deliveries and it is free of any legal, moral, ethical or religious objections, providing a high number of multipotent CD34+ progenitor and stem cells. Using ex vivo isolated CD34+ cells from human umbilical cord blood (hUCB) have emerged as promising candidates to treat various diseases, including exogenous pathogenic infections. We have expanded to build a rational approach to study the effect of CD34+ cells after damaged liver tissues by the devastating human parasitic flatworm Schistosoma mansoni. Methods and Results: Experimental studies were conducted in the Department of Zoology, Faculty of Science and Departments of Parasitology and Physiology, Faculty of Medicine, SCU, Egypt. We have studied the impact of ex vivo preparation of CD34+ cells from hUCB on S. mansoni-induced liver fibrosis de novo, and treated for shorter and longer periods in vivo. Ova count, ALT and albumin were measured at specific time interval and histopathological examination of liver was conducted to confirm the biochemical results. The data obtained were statistically analyzed by ANOVA between groups. It was found that the administration of CD34+ cells have modestly reduced liver damage; reduced the S. mansoni infection associated elevation in serum levels of ALT; significantly improved serum levels of albumin and reduced egg granuloma diameter in the livers. Conclusions: We demonstrated that CD34+ cells can markedly ameliorated liver fibrosis in vivo and may be beneficial for therapy to recover organ structure and/or function of S. mansoni-infected mice. PMID:25473447

  11. 40 CFR 63.864 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that uses an air pollution control system other than an ESP, wet scrubber, RTO, or fabric filter must... unit equipped with an alternative air pollution control system and monitoring operating parameters... affected source or process unit equipped with an alternative air pollution control system and monitoring...

  12. 40 CFR 63.864 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that uses an air pollution control system other than an ESP, wet scrubber, RTO, or fabric filter must... unit equipped with an alternative air pollution control system and monitoring operating parameters... affected source or process unit equipped with an alternative air pollution control system and monitoring...

  13. 40 CFR 63.864 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that uses an air pollution control system other than an ESP, wet scrubber, RTO, or fabric filter must... unit equipped with an alternative air pollution control system and monitoring operating parameters... affected source or process unit equipped with an alternative air pollution control system and monitoring...

  14. 142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN IN SOUTHWEST PORTION OF CONTROL ROOM (214), LSB (BLDG. 751), FACING WEST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  15. Feed-forward control of a solid oxide fuel cell system with anode offgas recycle

    NASA Astrophysics Data System (ADS)

    Carré, Maxime; Brandenburger, Ralf; Friede, Wolfgang; Lapicque, François; Limbeck, Uwe; da Silva, Pedro

    2015-05-01

    In this work a combined heat and power unit (CHP unit) based on the solid oxide fuel cell (SOFC) technology is analysed. This unit has a special feature: the anode offgas is partially recycled to the anode inlet. Thus it is possible to increase the electrical efficiency and the system can be operated without external water feeding. A feed-forward control concept which allows secure operating conditions of the CHP unit as well as a maximization of its electrical efficiency is introduced and validated experimentally. The control algorithm requires a limited number of measurement values and few deterministic relations for its description.

  16. Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment

    PubMed Central

    Mantilla, Carlos B.; Seven, Yasin B.; Sieck, Gary C.

    2014-01-01

    Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation, but are also active in other non-ventilatory behaviors, including coughing, sneezing, vomiting, defecation and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely-distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. PMID:24746055

  17. 26 CFR 1.956-1 - Shareholder's pro rata share of a controlled foreign corporation's increase in earnings invested...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... controlled foreign corporation's investment of earnings in United States property—(1) Dividend limitation... foreign corporation's increase in earnings invested in United States property. 1.956-1 Section 1.956-1...) INCOME TAXES Controlled Foreign Corporations § 1.956-1 Shareholder's pro rata share of a controlled...

  18. 77 FR 46373 - Field Release of Aphelinus glycinis for the Biological Control of the Soybean Aphid in the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-03

    ... Inspection Service [Docket No APHIS-2012-0061] Field Release of Aphelinus glycinis for the Biological Control... for the biological control of the soybean aphid, Aphis glycines, in the continental United States. We... glycinis for the Biological Control of the Soybean Aphid in the Continental United States'' (March 2012...

  19. Design of BLDCM emulator for transmission control units

    NASA Astrophysics Data System (ADS)

    Liu, Chang; He, Yongyi; Zhang, Bodong

    2018-04-01

    According to the testing requirements of the transmission control unit, a brushless DC motor emulating system is designed based on motor simulation and power hardware-in-the-loop. The discrete motor model is established and a real-time numerical method is designed to solve the motor states. The motor emulator directly interacts with power stage of the transmission control unit using a power-efficient circuit topology and is compatible with sensor-less control. Experiments on a laboratory prototype help to verify that the system can emulate the real motor currents and voltages whenever the motor is starting up or suddenly loaded.

  20. System and method for identifying, reporting, and evaluating presence of substance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Maurice; Lusby, Michael; Van Hook, Arthur

    A system and method for identifying, reporting, and evaluating a presence of a solid, liquid, gas, or other substance of interest, particularly a dangerous, hazardous, or otherwise threatening chemical, biological, or radioactive substance. The system comprises one or more substantially automated, location self-aware remote sensing units; a control unit; and one or more data processing and storage servers. Data is collected by the remote sensing units and transmitted to the control unit; the control unit generates and uploads a report incorporating the data to the servers; and thereafter the report is available for review by a hierarchy of responsive andmore » evaluative authorities via a wide area network. The evaluative authorities include a group of relevant experts who may be widely or even globally distributed.« less

  1. System and method for identifying, reporting, and evaluating presence of substance

    DOEpatents

    Smith, Maurice [Kansas City, MO; Lusby, Michael [Kansas City, MO; Van Hook, Arthur [Lotawana, MO; Cook, Charles J [Raytown, MO; Wenski, Edward G [Lenexa, KS; Solyom, David [Overland Park, KS

    2012-02-14

    A system and method for identifying, reporting, and evaluating a presence of a solid, liquid, gas, or other substance of interest, particularly a dangerous, hazardous, or otherwise threatening chemical, biological, or radioactive substance. The system comprises one or more substantially automated, location self-aware remote sensing units; a control unit; and one or more data processing and storage servers. Data is collected by the remote sensing units and transmitted to the control unit; the control unit generates and uploads a report incorporating the data to the servers; and thereafter the report is available for review by a hierarchy of responsive and evaluative authorities via a wide area network. The evaluative authorities include a group of relevant experts who may be widely or even globally distributed.

  2. System And Method For Identifying, Reporting, And Evaluating Presence Of Substance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Maurice; Lusby, Michael; Hook, Arthur Van

    A system and method for identifying, reporting, and evaluating a presence of a solid, liquid, gas, or other substance of interest, particularly a dangerous, hazardous, or otherwise threatening chemical, biological, or radioactive substance. The system comprises one or more substantially automated, location self-aware remote sensing units; a control unit; and one or more data processing and storage servers. Data is collected by the remote sensing units and transmitted to the control unit; the control unit generates and uploads a report incorporating the data to the servers; and thereafter the report is available for review by a hierarchy of responsive andmore » evaluative authorities via a wide area network. The evaluative authorities include a group of relevant experts who may be widely or even globally distributed.« less

  3. 40 CFR 52.1488 - Visibility protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... substituting equivalent or superior control technology, provided such technology meets applicable emission... operator shall meet the following deadlines for design and construction of the emission control equipment... binding contract to design the SO2, opacity and NOX control systems for Unit 1 and Unit 2 by March 1, 2003...

  4. 40 CFR 52.1488 - Visibility protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... substituting equivalent or superior control technology, provided such technology meets applicable emission... operator shall meet the following deadlines for design and construction of the emission control equipment... binding contract to design the SO2, opacity and NOX control systems for Unit 1 and Unit 2 by March 1, 2003...

  5. 40 CFR 52.1488 - Visibility protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... substituting equivalent or superior control technology, provided such technology meets applicable emission... operator shall meet the following deadlines for design and construction of the emission control equipment... binding contract to design the SO2, opacity and NOX control systems for Unit 1 and Unit 2 by March 1, 2003...

  6. 40 CFR 52.1488 - Visibility protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... substituting equivalent or superior control technology, provided such technology meets applicable emission... operator shall meet the following deadlines for design and construction of the emission control equipment... binding contract to design the SO2, opacity and NOX control systems for Unit 1 and Unit 2 by March 1, 2003...

  7. 21 CFR 211.100 - Written procedures; deviations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...

  8. 21 CFR 211.100 - Written procedures; deviations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...

  9. 21 CFR 211.100 - Written procedures; deviations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...

  10. 21 CFR 211.100 - Written procedures; deviations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...

  11. 21 CFR 211.100 - Written procedures; deviations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Process Controls § 211.100 Written procedures; deviations. (a) There shall be written procedures for production and process control designed to assure that the drug products have the identity, strength, quality... approved by the appropriate organizational units and reviewed and approved by the quality control unit. (b...

  12. Software Development for EECU Platform of Turbofan Engine

    NASA Astrophysics Data System (ADS)

    Kim, Bo Gyoung; Kwak, Dohyup; Kim, Byunghyun; Choi, Hee ju; Kong, Changduk

    2017-04-01

    The turbofan engine operation consists of a number of hardware and software. The engine is controlled by Electronic Engine Control Unit (EECU). In order to control the engine, EECU communicates with an aircraft system, Actuator Drive Unit (ADU), Engine Power Unit (EPU) and sensors on the engine. This paper tried to investigate the process form starting to taking-off and aims to design the EECU software mode and defined communication data format. The software is implemented according to the designed software mode.

  13. 8. SHEET 2, CONTROL HOUSE FOR DRY DOCK. United Engineering ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. SHEET 2, CONTROL HOUSE FOR DRY DOCK. United Engineering Company Ltd., Alameda Shipyard, Ship Repair Facilities, Office Building. John Hudspeth, Architect, at foot of Main Street, Alameda, Calif. Sheet no. 2 of 2 sheets, Plan no. 10,507. Various scales. January 4, 1943, last revised 1/19/43. U.S. Navy, Bureau of Yards & Docks, Contract no. bs 76. Approved for construction October 9, 1943. blueprint - United Engineering Company Shipyard, Control House for Dry Dock, 2900 Main Street, Alameda, Alameda County, CA

  14. Command, Control, Communications, Computers and Intelligence Electronic Warfare (C4IEW) Project Book, Fiscal Year 1994. (Non-FOUO Version)

    DTIC Science & Technology

    1994-04-01

    TSW-7A, AIR TRAFFIC CONTROL CENTRAL (ATCC) 32- 8 AN/TTC-41(V), CENTRAL OFFICE, TELEPHONE, AUTOMATIC 32- 9 MISSILE COUNTERMEASURE DEVICE (MCD) .- 0 MK...a Handheld Terminal Unit (HTU), Portable Computer Unit (PCU), Transportable Computer Unit (TCU), and compatible NOI peripheral devices . All but the...CLASSIFICATION: ASARC-III, Jun 80, Standard. I I I AN/TIC-39 IS A MOBILE , AUTOMATIC , MODULAR ELECTRONIC CIRCUIT SWITCH UNDER PROCESSOR CONTROL WITH INTEGRAL

  15. Direct cortical control of 3D neuroprosthetic devices.

    PubMed

    Taylor, Dawn M; Tillery, Stephen I Helms; Schwartz, Andrew B

    2002-06-07

    Three-dimensional (3D) movement of neuroprosthetic devices can be controlled by the activity of cortical neurons when appropriate algorithms are used to decode intended movement in real time. Previous studies assumed that neurons maintain fixed tuning properties, and the studies used subjects who were unaware of the movements predicted by their recorded units. In this study, subjects had real-time visual feedback of their brain-controlled trajectories. Cell tuning properties changed when used for brain-controlled movements. By using control algorithms that track these changes, subjects made long sequences of 3D movements using far fewer cortical units than expected. Daily practice improved movement accuracy and the directional tuning of these units.

  16. Facility versus unit level reporting of quality indicators in nursing homes when performance monitoring is the goal

    PubMed Central

    Norton, Peter G; Murray, Michael; Doupe, Malcolm B; Cummings, Greta G; Poss, Jeff W; Squires, Janet E; Teare, Gary F; Estabrooks, Carole A

    2014-01-01

    Objectives To demonstrate the benefit of defining operational management units in nursing homes and computing quality indicators on these units as well as on the whole facility. Design Calculation of adjusted Resident Assessment Instrument – Minimum Data Set 2.0 (RAI–MDS 2.0) quality indicators for: PRU05 (prevalence of residents with a stage 2–4 pressure ulcer), PAI0X (prevalence of residents with pain) and DRG01 (prevalence of residents receiving an antipsychotic with no diagnosis of psychosis), for quarterly assessments between 2007 and 2011 at unit and facility levels. Comparisons of these risk-adjusted quality indicators using statistical process control (control charts). Setting A representative sample of 30 urban nursing homes in the three Canadian Prairie Provinces. Measurements Explicit decision rules were developed and tested to determine whether the control charts demonstrated improving, worsening, unchanging or unclassifiable trends over the time period. Unit and facility performance were compared. Results In 48.9% of the units studied, unit control chart performance indicated different changes in quality over the reporting period than did the facility chart. Examples are provided to illustrate that these differences lead to quite different quality interventions. Conclusions Our results demonstrate the necessity of considering facility-level and unit-level measurement when calculating quality indicators derived from the RAI–MDS 2.0 data, and quite probably from any RAI measures. PMID:24523428

  17. Hierarchical control of motor units in voluntary contractions

    PubMed Central

    Contessa, Paola

    2012-01-01

    For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The “firing rate spectrum” presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units—both characteristics being well suited for generating and sustaining force during the fight-or-flight response. PMID:21975447

  18. Service equipment for use in hostile environments

    NASA Technical Reports Server (NTRS)

    Dolce, James L. (Inventor); Gordon, Andrew L. (Inventor)

    1994-01-01

    Service equipment for use in hostile environments includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit and stationary unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.

  19. An examination of the origin and evolution of additional tandem repeats in the mitochondrial DNA control region of Japanese sika deer (Cervus Nippon).

    PubMed

    Ba, Hengxing; Wu, Lang; Liu, Zongyue; Li, Chunyi

    2016-01-01

    Tandem repeat units are only detected in the left domain of the mitochondrial DNA control region in sika deer. Previous studies showed that Japanese sika deer have more tandem repeat units than its cousins from the Asian continent and Taiwan, which often have only three repeat units. To determine the origin and evolution of these additional repeat units in Japanese sika deer, we obtained the sequence of repeat units from an expanded dataset of the control region from all sika deer lineages. The functional constraint is inferred to act on the first repeat unit because this repeat has the least sequence divergence in comparison to the other units. Based on slipped-strand mispairing mechanisms, the illegitimate elongation model could account for the addition or deletion of these additional repeat units in the Japanese sika deer population. We also report that these additional repeat units could be occurring in the internal positions of tandem repeat regions, possibly via coupling with a homogenization mechanism within and among these lineages. Moreover, the increased number of repeat units in the Japanese sika deer population could reflect a balance between mutation and selection, as well as genetic drift.

  20. Development of a reference Phasor Measurement Unit (PMU) for the monitoring and control of grid stability and quality

    NASA Astrophysics Data System (ADS)

    Ndilimabaka, Hervé; Blanc, Isabelle

    2014-08-01

    This paper discusses the details of the development of a Phasor Measurement Unit regarding the requirements of the IEEE C37.118-2005 synchrophasor standard relative to steady-state conditions on grid monitoring and control. This phasor measurement unit is intended to be used for field tests sooner.

  1. 78 FR 73900 - Self-Regulatory Organizations; Financial Industry Regulatory Authority, Inc.; Notice of Filing of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-09

    ... discrete unit of an effective system of internal controls at a member firm are presumed to be related, and provided the following examples of the ``most discrete unit of an effective system of internal controls... that there should not be a presumption that algorithms within the most discrete trading units are...

  2. Pre-release assessment of Gadirtha inexacta a proposed biological control agent of Chinese tallow (Triadica sebifera) in the United States

    USDA-ARS?s Scientific Manuscript database

    Native to China, Chinese tallow, Triadica sebifera (Euphorbiaceae) is an aggressive woody invader in the southeastern United States. The noctuid, Gadirtha inexacta, is a multivoltine herbivore attacking this plant in China. To evaluate its potential as a biological control agent in the United States...

  3. 47 CFR 90.421 - Operation of mobile station units not under the control of the licensee.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Operating Requirements § 90... unauthorized operation of such units not under its control. (a) Public Safety Pool. (1) Mobile units licensed in the Public Safety Pool may be installed in any vehicle which in an emergency would require...

  4. A system for the delivery of programmable, adaptive stimulation intensity envelopes for drop foot correction applications.

    PubMed

    Breen, P P; O'Keeffe, D T; Conway, R; Lyons, G M

    2006-03-01

    We describe the design of an intelligent drop foot stimulator unit for use in conjunction with a commercial neuromuscular electrical nerve stimulation (NMES) unit, the NT2000. The developed micro-controller unit interfaces to a personal computer (PC) and a graphical user interface (GUI) allows the clinician to graphically specify the shape of the stimulation intensity envelope required for a subject undergoing drop foot correction. The developed unit is based on the ADuC812S micro-controller evaluation board from Analog Devices and uses two force sensitive resistor (FSR) based foot-switches to control application of stimulus. The unit has the ability to display to the clinician how the stimulus intensity envelope is being delivered during walking using a data capture capability. The developed system has a built-in algorithm to dynamically adjust the delivery of stimulus to reflect changes both within the gait cycle and from cycle to cycle. Thus, adaptive control of stimulus intensity is achieved.

  5. A containerless levitation setup for liquid processing in a superconducting magnet.

    PubMed

    Lu, Hui-Meng; Yin, Da-Chuan; Li, Hai-Sheng; Geng, Li-Qiang; Zhang, Chen-Yan; Lu, Qin-Qin; Guo, Yun-Zhu; Guo, Wei-Hong; Shang, Peng; Wakayama, Nobuko I

    2008-09-01

    Containerless processing of materials is considered beneficial for obtaining high quality products due to the elimination of the detrimental effects coming from the contact with container walls. Many containerless processing methods are realized by levitation techniques. This paper describes a containerless levitation setup that utilized the magnetization force generated in a gradient magnetic field. It comprises a levitation unit, a temperature control unit, and a real-time observation unit. Known volume of liquid diamagnetic samples can be levitated in the levitation chamber, the temperature of which is controlled using the temperature control unit. The evolution of the levitated sample is observed in real time using the observation unit. With this setup, containerless processing of liquid such as crystal growth from solution can be realized in a well-controlled manner. Since the levitation is achieved using a superconducting magnet, experiments requiring long duration time such as protein crystallization and simulation of space environment for living system can be easily succeeded.

  6. A Transformation Approach to Optimal Control Problems with Bounded State Variables

    NASA Technical Reports Server (NTRS)

    Hanafy, Lawrence Hanafy

    1971-01-01

    A technique is described and utilized in the study of the solutions to various general problems in optimal control theory, which are converted in to Lagrange problems in the calculus of variations. This is accomplished by mapping certain properties in Euclidean space onto closed control and state regions. Nonlinear control problems with a unit m cube as control region and unit n cube as state region are considered.

  7. Reduced Order Adaptive Controllers for Distributed Parameter Systems

    DTIC Science & Technology

    2005-09-01

    pitch moment [J313. Neural Network adaptive output feedback control for intensive care unit sedation and intraop- erative anesthesia . Neural network...depth of anesthesia for noncardiac surgery [C3, J15]. These results present an extension of [C8, J9, J10]. Modelling and vibration control of...for Intensive Care Unit Sedation and Operating Room Hypnosis , Submitted to 6 Special Issue of SIAM Journal of Control and Optimization on Control

  8. Examining the relationships between span of control and manager job and unit performance outcomes.

    PubMed

    Wong, Carol A; Elliott-Miller, Pat; Laschinger, Heather; Cuddihy, Michael; Meyer, Raquel M; Keatings, Margaret; Burnett, Camille; Szudy, Natalie

    2015-03-01

    Our aim was to examine the combination of frontline manager (FLM) personal characteristics and span of control (SOC) on their job and unit performance outcomes. Healthcare downsizing and reform have contributed to larger spans for FLMs in Canadian hospitals and increased concerns about manager workload. Despite a heightened awareness of SOC issues among decision makers, there is limited empirical evidence related to the effects of SOC on outcomes. A non-experimental predictive survey design was used to examine FLM SOC in 14 Canadian academic hospitals. Managers (n = 121) completed an online survey of work characteristics and The Ottawa Hospital (TOH) SOC tool. Unit turnover data were collected from organisational databases. The combination of SOC and core self-evaluation significantly predicted role overload, work control and job satisfaction, but only SOC predicted unit adverse outcomes and neither significantly predicted unit turnover. The findings contribute to an understanding of connections between the combination of SOC and core self-evaluation and manager job and unit performance outcomes. Organisational strategies to create manageable FLM SOC are essential to ensure exemplary job and unit outcomes. Core self-evaluation is a personality characteristic that may enhance manager performance in the face of high spans of control. © 2013 John Wiley & Sons Ltd.

  9. Controlling Energy Radiations of Electromagnetic Waves via Frequency Coding Metamaterials

    PubMed Central

    Wu, Haotian; Liu, Shuo; Wan, Xiang; Zhang, Lei; Wang, Dan; Li, Lianlin

    2017-01-01

    Metamaterials are artificial structures composed of subwavelength unit cells to control electromagnetic (EM) waves. The spatial coding representation of metamaterial has the ability to describe the material in a digital way. The spatial coding metamaterials are typically constructed by unit cells that have similar shapes with fixed functionality. Here, the concept of frequency coding metamaterial is proposed, which achieves different controls of EM energy radiations with a fixed spatial coding pattern when the frequency changes. In this case, not only different phase responses of the unit cells are considered, but also different phase sensitivities are also required. Due to different frequency sensitivities of unit cells, two units with the same phase response at the initial frequency may have different phase responses at higher frequency. To describe the frequency coding property of unit cell, digitalized frequency sensitivity is proposed, in which the units are encoded with digits “0” and “1” to represent the low and high phase sensitivities, respectively. By this merit, two degrees of freedom, spatial coding and frequency coding, are obtained to control the EM energy radiations by a new class of frequency‐spatial coding metamaterials. The above concepts and physical phenomena are confirmed by numerical simulations and experiments. PMID:28932671

  10. Asthma in Adults Fact Sheet

    MedlinePlus

    ... American Lung Association Epidemiology and Statistics Unit using SPSS software. Center for Disease Control and Prevention. Behavioral ... American Lung Association Epidemiology and Statistics Unit using SPSS software. Centers for Disease Control and Prevention. National ...

  11. Crash problem definition and safety benefits methodology for stability control for single-unit medium and heavy trucks and large-platform buses

    DOT National Transportation Integrated Search

    2009-10-01

    This report presents the findings of a comprehensive engineering analysis of electronic stability control (ESC) and roll stability control (RSC) systems for single-unit medium and heavy trucks and large-platform buses. This report details the applica...

  12. Programmable Logic Controllers. Teacher Edition.

    ERIC Educational Resources Information Center

    Rauh, Bob; Kaltwasser, Stan

    These materials were developed for a seven-unit secondary or postsecondary education course on programmable logic controllers (PLCs) that treats most of the skills needed to work effectively with PLCs as programming skills. The seven units of the course cover the following topics: fundamentals of programmable logic controllers; contracts, timers,…

  13. 40 CFR 76.10 - Alternative emission limitations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...; and (ii) The installed NOX emission control system has been designed to meet the applicable emission... that the unit and NOX emission control system were operated in accordance with the bid and design specifications on which the design of the NOX emission control system was based; and (C) Unit operating data as...

  14. 40 CFR 76.10 - Alternative emission limitations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...; and (ii) The installed NOX emission control system has been designed to meet the applicable emission... that the unit and NOX emission control system were operated in accordance with the bid and design specifications on which the design of the NOX emission control system was based; and (C) Unit operating data as...

  15. 50 CFR 35.10 - Controlled burning.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Controlled burning. 35.10 Section 35.10 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... burning. Controlled burning will be permitted on wilderness units when such burning will contribute to the...

  16. 50 CFR 35.10 - Controlled burning.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Controlled burning. 35.10 Section 35.10 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... burning. Controlled burning will be permitted on wilderness units when such burning will contribute to the...

  17. 50 CFR 35.10 - Controlled burning.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Controlled burning. 35.10 Section 35.10 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... burning. Controlled burning will be permitted on wilderness units when such burning will contribute to the...

  18. 50 CFR 35.10 - Controlled burning.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Controlled burning. 35.10 Section 35.10 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... burning. Controlled burning will be permitted on wilderness units when such burning will contribute to the...

  19. 50 CFR 35.10 - Controlled burning.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Controlled burning. 35.10 Section 35.10 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... burning. Controlled burning will be permitted on wilderness units when such burning will contribute to the...

  20. System Engineering and Integration Contract for Implementation of the National Airspace System Plan. Volume 2. Section 5.0 NAS Plan Project Findings.

    DTIC Science & Technology

    1984-08-01

    and FPS-60 -’ vacuum-tube radars. There will be remote control interface units ( RCIU ) for tube-type radars, and an ARSR-3 relocation and RIH package...Facility RCE Remote Control Equipment; Radio Control Equipment RCIU Remote Control Interface Units RCO Remote Communications Outlet RDCC Research

  1. Development of a simple MR-compatible vibrotactile stimulator using a planar-coil-type actuator.

    PubMed

    Kim, Hyung-Sik; Choi, Mi-Hyun; Chung, Yoon-Gi; Kim, Sung-Phil; Jun, Jae-Hoon; Park, Jang-Yeon; Yi, Jeong-Han; Park, Jong-Rak; Lim, Dae-Woon; Chung, Soon-Cheol

    2013-06-01

    For this study, we developed a magnetic resonance (MR)-compatible vibrotactile stimulator using a planar-coil-type actuator. The newly developed vibrotactile stimulator consists of three units: control unit, drive unit, and planar-coil-type actuator. The control unit controls frequency, intensity, time, and channel, and transfers the stimulation signals to the drive unit. The drive unit operates the planar-coil-type actuator in response to commands from the control unit. The planar-coil-type actuator, which uses a planar coil instead of conventional electric wire, generates vibrating stimulation through interaction of the current of the planar coil with the static magnetic field of the MR scanner. Even though the developed tactile stimulating system is small, simple, and inexpensive, it has a wide range of stimulation frequencies (20 ~ 400 Hz, at 40 levels) and stimulation intensities (0 ~ 7 V, at 256 levels). The stimulation intensity does not change due to frequency changes. Since the transient response time is a few microseconds, the stimulation time can be controlled on a scale of microseconds. In addition, this actuator has the advantages of providing highly repeatable stimulation, being durable, being able to assume various shapes, and having an adjustable contact area with the skin. The new stimulator operated stably in an MR environment without affecting the MR images. Using functional magnetic resonance imaging, we observed the brain activation changes resulting from stimulation frequency and intensity changes.

  2. Autofocus system and autofocus method for focusing on a surface

    DOEpatents

    O'Neill, Mary Morabito

    2017-05-23

    An autofocus system includes an imaging device, a lens system and a focus control actuator that is configured to change a focus position of the imaging device in relation to a stage. The electronic control unit is configured to control the focus control actuator to a plurality of predetermined focus positions, and activate the imaging device to obtain an image at predetermined positions and then apply a spatial filter to the obtained images. This generates a filtered image for the obtained images. The control unit determines a focus score for the filtered images such that the focus score corresponds to a degree of focus in the obtained images. The control unit identifies a best focus position by comparing the focus score of the filtered images, and controls the focus control actuator to the best focus position corresponding to the highest focus score.

  3. Digital communication system

    NASA Technical Reports Server (NTRS)

    Monford, L. G., Jr. (Inventor)

    1974-01-01

    A digital communication system is reported for parallel operation of 16 or more transceiver units with the use of only four interconnecting wires. A remote synchronization circuit produces unit address control words sequentially in data frames of 16 words. Means are provided in each transceiver unit to decode calling signals and to transmit calling and data signals. The transceivers communicate with each other over one data line. The synchronization unit communicates the address control information to the transceiver units over an address line and further provides the timing information over a clock line. A reference voltage level or ground line completes the interconnecting four wire hookup.

  4. 40 CFR 1033.650 - Incidental use exemption for Canadian and Mexican locomotives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Special Compliance... the United States and that enter the United States temporarily from Canada or Mexico. We will approve...

  5. 40 CFR 1033.650 - Incidental use exemption for Canadian and Mexican locomotives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Special Compliance... the United States and that enter the United States temporarily from Canada or Mexico. We will approve...

  6. 40 CFR 1033.650 - Incidental use exemption for Canadian and Mexican locomotives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Special Compliance... the United States and that enter the United States temporarily from Canada or Mexico. We will approve...

  7. 40 CFR 1033.650 - Incidental use exemption for Canadian and Mexican locomotives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Special Compliance... the United States and that enter the United States temporarily from Canada or Mexico. We will approve...

  8. 40 CFR 1033.650 - Incidental use exemption for Canadian and Mexican locomotives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Special Compliance... the United States and that enter the United States temporarily from Canada or Mexico. We will approve...

  9. Fluidic Emergency Thruster for Aircraft

    NASA Technical Reports Server (NTRS)

    Honda, T. S.

    1972-01-01

    The design, development, fabrication and test evaluation of two prototype fluidic emergency thrusters (FET) for aircraft stabilization are discussed. The fluidic control units were designed to provide, between two diametrically opposed nozzles, a thrust differential proportional to an input voltage signal. The emergency roll control requirements of the X-14 VTOL research aircraft were defined as typical design goals. Two control units, one on each wing tip, are intended to provide a maximum thrust of 224 pounds per unit. The units are designed to operate with 2500 psig, 2000 F gas from a solid propellant gas generator. The emergency system including the gas generator was designed to add less than 11 pounds per wing tip. The operating time under emergency conditions was specified as five seconds. The fluidic emergency thruster is similar in concept to a JATO system but has the added feature of controllable thrust.

  10. Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment.

    PubMed

    Mantilla, Carlos B; Seven, Yasin B; Sieck, Gary C

    2014-01-01

    Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation but are also active in other nonventilatory behaviors, including coughing, sneezing, vomiting, defecation, and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly, properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors, whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing, or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. © 2014 Elsevier B.V. All rights reserved.

  11. Cost-effective retrofit technology for reducing peak power demand in small and medium commercial buildings

    DOE PAGES

    Nutaro, James J.; Fugate, David L.; Kuruganti, Teja; ...

    2015-05-27

    We describe a cost-effective retrofit technology that uses collective control of multiple rooftop air conditioning units to reduce the peak power consumption of small and medium commercial buildings. The proposed control uses a model of the building and air conditioning units to select an operating schedule for the air conditioning units that maintains a temperature set point subject to a constraint on the number of units that may operate simultaneously. A prototype of this new control system was built and deployed in a large gymnasium to coordinate four rooftop air conditioning units. Based on data collected while operating this prototype,more » we estimate that the cost savings achieved by reducing peak power consumption is sufficient to repay the cost of the prototype within a year.« less

  12. Computer Vision for Artificially Intelligent Robotic Systems

    NASA Astrophysics Data System (ADS)

    Ma, Chialo; Ma, Yung-Lung

    1987-04-01

    In this paper An Acoustic Imaging Recognition System (AIRS) will be introduced which is installed on an Intelligent Robotic System and can recognize different type of Hand tools' by Dynamic pattern recognition. The dynamic pattern recognition is approached by look up table method in this case, the method can save a lot of calculation time and it is practicable. The Acoustic Imaging Recognition System (AIRS) is consist of four parts -- position control unit, pulse-echo signal processing unit, pattern recognition unit and main control unit. The position control of AIRS can rotate an angle of ±5 degree Horizental and Vertical seperately, the purpose of rotation is to find the maximum reflection intensity area, from the distance, angles and intensity of the target we can decide the characteristic of this target, of course all the decision is target, of course all the decision is processed bye the main control unit. In Pulse-Echo Signal Process Unit, we ultilize the correlation method, to overcome the limitation of short burst of ultrasonic, because the Correlation system can transmit large time bandwidth signals and obtain their resolution and increased intensity through pulse compression in the correlation receiver. The output of correlator is sampled and transfer into digital data by u law coding method, and this data together with delay time T, angle information OH, eV will be sent into main control unit for further analysis. The recognition process in this paper, we use dynamic look up table method, in this method at first we shall set up serval recognition pattern table and then the new pattern scanned by Transducer array will be devided into serval stages and compare with the sampling table. The comparison is implemented by dynamic programing and Markovian process. All the hardware control signals, such as optimum delay time for correlator receiver, horizental and vertical rotation angle for transducer plate, are controlled by the Main Control Unit, the Main Control Unit also handles the pattern recognition process. The distance from the target to the transducer plate is limitted by the power and beam angle of transducer elements, in this AIRS Model, we use a narrow beam transducer and it's input voltage is 50V p-p. A RobOt equipped with AIRS can not only measure the distance from the target but also recognize a three dimensional image of target from the image lab of Robot memory. Indexitems, Accoustic System, Supersonic transducer, Dynamic programming, Look-up-table, Image process, pattern Recognition, Quad Tree, Quadappoach.

  13. Improved Performance Characteristics For Indium Antimonide Photovoltaic Detector Arrays Using A FET-Switched Multiplexing Technique

    NASA Astrophysics Data System (ADS)

    Ma, Yung-Lung; Ma, Chialo

    1987-03-01

    In this paper An Acoustic Imaging Recognition System (AIRS) will be introduced which is installed on an Intelligent Robotic System and can recognize different type of Hand tools' by Dynamic pattern recognition. The dynamic pattern recognition is approached by look up table method in this case, the method can save a lot of calculation time and it is practicable. The Acoustic Imaging Recognition System (AIRS) is consist of four parts _ position control unit, pulse-echo signal processing unit, pattern recognition unit and main control unit. The position control of AIRS can rotate an angle of ±5 degree Horizental and Vertical seperately, the purpose of rotation is to find the maximum reflection intensity area, from the distance, angles and intensity of the target we can decide the characteristic of this target, of course all the decision is target, of course all the decision is processed by the main control unit. In Pulse-Echo Signal Process Unit, we utilize the correlation method, to overcome the limitation of short burst of ultrasonic, because the Correlation system can transmit large time bandwidth signals and obtain their resolution and increased intensity through pulse compression in the correlation receiver. The output of correlator is sampled and transfer into digital data by p law coding method, and this data together with delay time T, angle information eH, eV will be sent into main control unit for further analysis. The recognition process in this paper, we use dynamic look up table method, in this method at first we shall set up serval recognition pattern table and then the new pattern scanned by Transducer array will be devided into serval stages and compare with the sampling table. The comparison is implemented by dynamic programing and Markovian process. All the hardware control signals, such as optimum delay time for correlator receiver, horizental and vertical rotation angle for transducer plate, are controlled by the Main Control Unit, the Main Control Unit also handles the pattern recognition process. The distance from the target to the transducer plate is limitted by the power and beam angle of transducer elements, in this AIRS Models, we use a narrow beam transducer and it's input voltage is 50V p-p. A Robot equipped with AIRS can not only measure the distance from the target but also recognize a three dimensional image of target from the image lab of Robot memory. Indexitems, Accoustic System, Supersonic transducer, Dynamic programming, Look-up-table, Image process, pattern Recognition, Quad Tree, Quadappoach.

  14. A Short Guide to U.S. Arms Control Policy.

    ERIC Educational Resources Information Center

    Howard, Norman, Ed.; Sussman, Colleen, Ed.

    Steps the United States is taking to lessen the danger of war while building international confidence and security are described. The commitment of the United States to arms control is based on the conviction that the United States and the Soviet Union have a common interest in the avoidance of nuclear war and the survival of the human race. A…

  15. A re-evaluation of a case-control model with contaminated controls for resource selection studies

    Treesearch

    Christopher T. Rota; Joshua J. Millspaugh; Dylan C. Kesler; Chad P. Lehman; Mark A. Rumble; Catherine M. B. Jachowski

    2013-01-01

    A common sampling design in resource selection studies involves measuring resource attributes at sample units used by an animal and at sample units considered available for use. Few models can estimate the absolute probability of using a sample unit from such data, but such approaches are generally preferred over statistical methods that estimate a relative probability...

  16. State Budgets, Unit Allocations, and Unit Emissions Rates

    EPA Pesticide Factsheets

    This Technical Support Document (TSD) provides information that supports EPA’s determination of state emissions budgets, unit-level allocations, direct control rate limits, and new unit set-asides for the Transport Rule proposal.

  17. The Radio Frequency Health Node Wireless Sensor System

    NASA Technical Reports Server (NTRS)

    Valencia, J. Emilio; Stanley, Priscilla C.; Mackey, Paul J.

    2009-01-01

    The Radio Frequency Health Node (RFHN) wireless sensor system differs from other wireless sensor systems in ways originally intended to enhance utility as an instrumentation system for a spacecraft. The RFHN can also be adapted to use in terrestrial applications in which there are requirements for operational flexibility and integrability into higher-level instrumentation and data acquisition systems. As shown in the figure, the heart of the system is the RFHN, which is a unit that passes commands and data between (1) one or more commercially available wireless sensor units (optionally, also including wired sensor units) and (2) command and data interfaces with a local control computer that may be part of the spacecraft or other engineering system in which the wireless sensor system is installed. In turn, the local control computer can be in radio or wire communication with a remote control computer that may be part of a higher-level system. The remote control computer, acting via the local control computer and the RFHN, cannot only monitor readout data from the sensor units but can also remotely configure (program or reprogram) the RFHN and the sensor units during operation. In a spacecraft application, the RFHN and the sensor units can also be configured more nearly directly, prior to launch, via a serial interface that includes an umbilical cable between the spacecraft and ground support equipment. In either case, the RFHN wireless sensor system has the flexibility to be configured, as required, with different numbers and types of sensors for different applications. The RFHN can be used to effect realtime transfer of data from, and commands to, the wireless sensor units. It can also store data for later retrieval by an external computer. The RFHN communicates with the wireless sensor units via a radio transceiver module. The modular design of the RFHN makes it possible to add radio transceiver modules as needed to accommodate additional sets of wireless sensor units. The RFHN includes a core module that performs generic computer functions, including management of power and input, output, processing, and storage of data. In a typical application, the processing capabilities in the RFHN are utilized to perform preprocessing, trending, and fusion of sensor data. The core module also serves as the unit through which the remote control computer configures the sensor units and the rest of the RFHN.

  18. Army Officer Duty Module Manual.

    DTIC Science & Technology

    1975-10-01

    14l 3( RELATIVE CRITICALITY OF THIS Not Least (2) (3) The most PART (MOOULE) TO ENTIRE JOB aplicable critical Average Critical critical a. In actual...3 Directs and controls operations of mobile communications O- support unit -36- I. - O-G-5 Establishes and controls mobile area signal center 0-6-6...ENGINEERING O-EE-1 Directs .and controls combat engineer unit O-EE-2 Directs and controls portable bridging O-EE-3 Directs and controls mobile water

  19. Biorational control programme for the German cockroach (Blattaria: Blattellidae) in selected urban communities.

    PubMed

    Shahraki, GholamHossein; Bin Ibrahim, Yusof; Noor, Hafidzi Mohd; Rafinejad, Javad; Shahar, Mohd Khadri

    2010-08-01

    This study assessed the effectiveness of a biorational control approach using 2% hydramethylnon gel bait on German cockroaches, Blattella germanica (L.) in some residential and hospital buildings in South Western Iran. In total, three buildings consisting of 150 apartment units and 101 hospital units were monitored weekly via sticky trap for German cockroach infestations over a period of eight months. These infested units were randomly subjected to intervention and control treatments. Pamphlets and posters were provided and lectures were given to support the educational programmes as a tactic of the biorational system. Survey on cockroach index for intervention units showed 67-94% recovery to achieve clean level of infestation for intervention units of the residential buildings and 83% for the hospital. Mean percentage reductions for treatment groups throughout the 15-week treatment period were 76.8% for the residential buildings and 88.1% for the hospital, showing significant differences compared to the control groups. Linear regression of infestation rates were recorded weekly after treatment and their negative slope for treatment groups substantiated significant reductions for interventions. The results of this study showed that biorational control method, using gel bait, educational programmes and sanitation, is an effective way to manage German cockroach infestation.

  20. Greenridge Multi-Pollutant Control Project Preliminary Public Design Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connell, Daniel P

    2009-01-12

    The Greenidge Multi-Pollutant Control Project is being conducted as part of the U.S. Department of Energy's Power Plant Improvement Initiative to demonstrate an innovative combination of air pollution control technologies that can cost-effectively reduce emissions of SO{sub 2}, NO{sub x}, Hg, acid gases (SO{sub 3}, HCl, and HF), and particulate matter from smaller coal-fired electrical generating units (EGUs). The multi-pollutant control system includes a hybrid selective non-catalytic reduction (SNCR)/in-duct selective catalytic reduction (SCR) system to reduce NOx emissions by {ge}60%, followed by a Turbosorp{reg_sign} circulating fluidized bed dry scrubber system to reduce emissions of SO{sub 2}, SO{sub 3}, HCl, andmore » HF by {ge}95%. Mercury removal of {ge}90% is also targeted via the co-benefits afforded by the in-duct SCR, dry scrubber, and baghouse and by injection of activated carbon upstream of the scrubber, as required. The technology is particularly well suited, because of its relatively low capital and maintenance costs and small space requirements, to meet the needs of coal-fired units with capacities of 50-300 MWe. There are about 440 such units in the United States that currently are not equipped with SCR, flue gas desulfurization (FGD), or mercury control systems. These smaller units are a valuable part of the nation's energy infrastructure, constituting about 60 GW of installed capacity. However, with the onset of the Clean Air Interstate Rule, Clean Air Mercury Rule, and various state environmental actions requiring deep reductions in emissions of SO{sub 2}, NO{sub x}, and mercury, the continued operation of these units increasingly depends upon the ability to identify viable air pollution control retrofit options for them. The large capital costs and sizable space requirements associated with conventional technologies such as SCR and wet FGD make these technologies unattractive for many smaller units. The Greenidge Project aims to confirm the commercial readiness of an emissions control system that is specifically designed to meet the environmental compliance requirements of these smaller coal-fired EGUs. The multi-pollutant control system is being installed and tested on the AES Greenidge Unit 4 (Boiler 6) by a team including CONSOL Energy Inc. as prime contractor, AES Greenidge LLC as host site owner, and Babcock Power Environmental Inc. as engineering, procurement, and construction contractor. All funding for the project is being provided by the U.S. Department of Energy, through its National Energy Technology Laboratory, and by AES Greenidge. AES Greenidge Unit 4 is a 107 MW{sub e} (net), 1950s vintage, tangentially-fired, reheat unit that is representative of many of the 440 smaller coal-fired units identified above. Following design and construction, the multi-pollutant control system will be demonstrated over an approximately 20-month period while the unit fires 2-4% sulfur eastern U.S. bituminous coal and co-fires up to 10% biomass. This Preliminary Public Design Report is the first in a series of two reports describing the design of the multi-pollutant control facility that is being demonstrated at AES Greenidge. Its purpose is to consolidate for public use all available nonproprietary design information on the Greenidge Multi-Pollutant Control Project. As such, the report includes a discussion of the process concept, design objectives, design considerations, and uncertainties associated with the multi-pollutant control system and also summarizes the design of major process components and balance of plant considerations for the AES Greenidge Unit 4 installation. The Final Public Design Report, the second report in the series, will update this Preliminary Public Design Report to reflect the final, as-built design of the facility and to incorporate data on capital costs and projected operating costs.« less

  1. Universal Controller for Spacecraft Mechanisms

    NASA Technical Reports Server (NTRS)

    Levanas, Greg; McCarthy, Thomas; Hunter, Don; Buchanan, Christine; Johnson, Michael; Cozy, Raymond; Morgan, Albert; Tran, Hung

    2006-01-01

    An electronic control unit has been fabricated and tested that can be replicated as a universal interface between the electronic infrastructure of a spacecraft and a brushless-motor (or other electromechanical actuator) driven mechanism that performs a specific mechanical function within the overall spacecraft system. The unit includes interfaces to a variety of spacecraft sensors, power outputs, and has selectable actuator control parameters making the assembly a mechanism controller. Several control topologies are selectable and reconfigurable at any time. This allows the same actuator to perform different functions during the mission life of the spacecraft. The unit includes complementary metal oxide/semiconductor electronic components on a circuit board of a type called rigid flex (signifying flexible printed wiring along with a rigid substrate). The rigid flex board is folded to make the unit fit into a housing on the back of a motor. The assembly has redundant critical interfaces, allowing the controller to perform time-critical operations when no human interface with the hardware is possible. The controller is designed to function over a wide temperature range without the need for thermal control, including withstanding significant thermal cycling, making it usable in nearly all environments that spacecraft or landers will endure. A prototype has withstood 1,500 thermal cycles between 120 and +85 C without significant deterioration of its packaging or electronic function. Because there is no need for thermal control and the unit is addressed through a serial bus interface, the cabling and other system hardware are substantially reduced in quantity and complexity, with corresponding reductions in overall spacecraft mass and cost.

  2. Pre-production Test Report for Transformer Abort Sensing and Control Unit.

    DTIC Science & Technology

    The purpose of the report is to describe the test equipment and procedure required for the pre-production testing of a transformer, pressure switch excitation, abort sensing and control unit. (Author)

  3. 40 CFR 63.773 - Inspection and monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... devices: (i) Except for control devices for small glycol dehydration units, a boiler or process heater in...) Except for control devices for small glycol dehydration units, a boiler or process heater with a design...

  4. 40 CFR 63.773 - Inspection and monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... devices: (i) Except for control devices for small glycol dehydration units, a boiler or process heater in...) Except for control devices for small glycol dehydration units, a boiler or process heater with a design...

  5. Poison control center - emergency number

    MedlinePlus

    For a POISON EMERGENCY call: 1-800-222-1222 ANYWHERE IN THE UNITED STATES This national hotline number will let you ... is a free and confidential service. All local poison control centers in the United States use this ...

  6. Comparison of competitive exclusion with classical cleaning and disinfection on bacterial load in pig nursery units.

    PubMed

    Luyckx, K; Millet, S; Van Weyenberg, S; Herman, L; Heyndrickx, M; Dewulf, J; De Reu, K

    2016-09-06

    Colonisation of the environment of nursery units by pathogenic micro-organisms is an important factor in the persistence and spread of endemic diseases in pigs and zoonotic pathogens. These pathogens are generally controlled by the use of antibiotics and disinfectants. Since an increasing resistance against these measures has been reported in recent years, methods such as competitive exclusion (CE) are promoted as promising alternatives. This study showed that the infection pressure in CE units after microbial cleaning was not reduced to the same degree as in control units. Despite sufficient administration of probiotic-type spores, the analysed bacteria did not decrease in number after 3 production rounds in CE units, indicating no competitive exclusion. In addition, no differences in feed conversion were found between piglets raised in CE and control units in our study. Also, no differences in faecal consistency (indicator for enteric diseases) was noticed. These results indicate that the CE protocol is not a valuable alternative for classical C&D.

  7. Transfusion of irradiated red blood cell units with a potassium adsorption filter: A randomized controlled trial.

    PubMed

    Cid, Joan; Villegas, Vanessa; Carbassé, Gloria; Alba, Cristina; Perea, Dolores; Lozano, Miguel

    2016-05-01

    The irradiation of red blood cells (RBCs) causes damage of the RBC membrane with increased potassium (K) leak during storage compared with nonirradiated RBC units of similar age. A previous in vitro study showed a mean reduction of K of 94 ± 5% with a potassium adsorption filter (PAF). A prospective, single-center, nonblinded, randomized controlled trial (RCT) was designed to evaluate the safety and efficacy of transfusing irradiated RBC units with the PAF. Patients 18 years of age or older who received irradiated RBC units due to chemotherapy-induced anemia were randomly assigned to receive irradiated RBC units with the PAF (PAF group) or with the standard blood infusion set (control group). Primary outcome measures were safety and efficacy of the PAF (absolute change in hemoglobin [Hb] and K, respectively, in patient's blood values after transfusing the irradiated RBC units with or without the PAF). A total of 63 irradiated RBC units were transfused to 17 patients in the control group, and a total of 56 irradiated RBC units were transfused to 13 patients in the PAF group. The absolute change of Hb (9.3 ± 6.3 g/L vs. 8.1 ± 5.8 g/L; p = 0.3) and the absolute change of K (-0.01 ± 0.4 mmol/L vs. -0.01 ± 0.3 mmol/L; p = 0.2) were comparable between the two groups of the trial. The transfusion of 1 irradiated RBC unit with the PAF was as safe and efficacious as the transfusion of 1 irradiated RBC unit with the standard blood infusion set in patients with chemotherapy-induced anemia. © 2016 AABB.

  8. Inferential control -- Part 1: Crude unit advanced controls pass accuracy and repeatability tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    San, Y.P.; Landells, K.C.; Mackay, D.C.

    1994-11-28

    An inferential model is one that provides a quality for which an analyzer is not available. This type of model uses readily available physical measurements -- such as temperatures, pressures, and flow rates -- to infer a quality such as kerosine flash point. The No. 2 crude distillation unit (CDU-2) at Singapore Refining Co. Pte. Ltd.'s Pulau Merlimau refinery has a nominal 130,000 b/d capacity. It produces naphtha, kerosine, diesel, and residue products from a wide range of crude blends. Over the past 12 months, extensive advanced control applications have been implemented on the unit. This first of two articlesmore » will describe the control system and its implementation. The second will outline the project's achievements, including reduced quality giveaway and increased profits. The paper describes background of the company and unit, the process, project implementation, the Infer model, model tuning, closed-loop control, feed rate maximization, and economic monitoring.« less

  9. 40 CFR 76.14 - Monitoring, recordkeeping, and reporting.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NOX emission control system to the owner or operator showing that such system was designed to meet the... emission control system that were not included in the design specifications and performance guarantee, but... regard to the following types of Group 1, Phase I units: (i) Units employing no new NOX emission control...

  10. 40 CFR 76.14 - Monitoring, recordkeeping, and reporting.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... NOX emission control system to the owner or operator showing that such system was designed to meet the... emission control system that were not included in the design specifications and performance guarantee, but... regard to the following types of Group 1, Phase I units: (i) Units employing no new NOX emission control...

  11. 40 CFR 76.14 - Monitoring, recordkeeping, and reporting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NOX emission control system to the owner or operator showing that such system was designed to meet the... emission control system that were not included in the design specifications and performance guarantee, but... regard to the following types of Group 1, Phase I units: (i) Units employing no new NOX emission control...

  12. 76 FR 37253 - Airworthiness Directives; Bombardier, Inc. Model DHC-8-400 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-27

    ... reports have been received on the elevator power control units (PCUs) where the shaft (tailstock) swaged... power control units (PCUs) where the shaft (tailstock) swaged bearing liners had shown a higher than... and difficulties in aircraft pitch control. This directive mandates a free-play check of the shaft...

  13. 76 FR 71470 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-18

    ... brackets that attach the power control unit (PCU) to the airframe could result in a loss of the rudder actuating system. The loss of both rudder PCU actuators could result in free play of the rudder control... failure of the mounting brackets that attach the power control unit (PCU) to the airframe could result in...

  14. 26 CFR 509.106 - Control of a United States enterprise by a Swiss enterprise.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Control of a United States enterprise by a Swiss enterprise. 509.106 Section 509.106 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS SWITZERLAND General Income Tax § 509.106 Control of...

  15. Recruitment of motor units in the medial gastrocnemius muscle during human quiet standing: is recruitment intermittent? What triggers recruitment?

    PubMed Central

    Loram, Ian D.; Muceli, Silvia; Merletti, Roberto; Farina, Dario

    2012-01-01

    The recruitment and the rate of discharge of motor units are determinants of muscle force. Within a motoneuron pool, recruitment and rate coding of individual motor units might be controlled independently, depending on the circumstances. In this study, we tested whether, during human quiet standing, the force of the medial gastrocnemius (MG) muscle is predominantly controlled by recruitment or rate coding. If MG control during standing was mainly due to recruitment, then we further asked what the trigger mechanism is. Is it determined internally, or is it related to body kinematics? While seven healthy subjects stood quietly, intramuscular electromyograms were recorded from the MG muscle with three pairs of wire electrodes. The number of active motor units and their mean discharge rate were compared for different sway velocities and positions. Motor unit discharges occurred more frequently when the body swayed faster and forward (Pearson R = 0.63; P < 0.0001). This higher likelihood of observing motor unit potentials was explained chiefly by the recruitment of additional units. During forward body shifts, the median number of units detected increased from 3 to 11 (P < 0.0001), whereas the discharge rate changed from 8 ± 1.1 (mean ± SD) to 10 ± 0.9 pulses/s (P = 0.001). Strikingly, motor units did not discharge continuously throughout standing. They were recruited within individual, forward sways and intermittently, with a modal rate of two recruitments per second. This modal rate is consistent with previous circumstantial evidence relating the control of standing to an intrinsic, higher level planning process. PMID:21994258

  16. Preparation of red blood cell concentrates and plasma units from whole blood held overnight using a hollow-fibre separation system.

    PubMed

    Johnson, L; Kwok, M; Marks, D C

    2015-02-01

    The ErySep system represents an alternative to centrifuge-based whole blood (WB) separation, using gravity and filtration through hollow-fibres (0·2 µm pore size) to produce red blood cell (RBC) and plasma components. The aim of this study was to characterise the quality of ErySep RBC and plasma units compared with standard products from WB held overnight. Two ABO-compatible WB units (n = 24) were pooled and split to produce matched products. One of the WB units was separated into components using the ErySep system (ErySep; n = 12), whereas the other units were separated by centrifugation (control; n = 12). RBC units were stored at 2-6 °C and assessed for in vitro quality over 42 days of storage. Plasma was frozen at -30 °C and tested upon thawing. Processing WB with the ErySep system took longer than controls. The ErySep RBC units were of an appropriate volume (307 ± 17 mL) and contained sufficient Hb (50 ± 2 g unit(-1) ). ErySep RBC components contained more microparticles relative to controls at expiry. The plasma volume, total protein, coagulation factor activity (fibrinogen, FV, FVIII) and number of microparticles was lower in the ErySep units compared with controls. Following overnight hold of WB, the ErySep system was capable of producing RBC components that met specifications. However, the ErySep plasma components did not meet quality specifications. © 2015 British Blood Transfusion Society.

  17. Recruitment of motor units in the medial gastrocnemius muscle during human quiet standing: is recruitment intermittent? What triggers recruitment?

    PubMed

    Vieira, Taian M M; Loram, Ian D; Muceli, Silvia; Merletti, Roberto; Farina, Dario

    2012-01-01

    The recruitment and the rate of discharge of motor units are determinants of muscle force. Within a motoneuron pool, recruitment and rate coding of individual motor units might be controlled independently, depending on the circumstances. In this study, we tested whether, during human quiet standing, the force of the medial gastrocnemius (MG) muscle is predominantly controlled by recruitment or rate coding. If MG control during standing was mainly due to recruitment, then we further asked what the trigger mechanism is. Is it determined internally, or is it related to body kinematics? While seven healthy subjects stood quietly, intramuscular electromyograms were recorded from the MG muscle with three pairs of wire electrodes. The number of active motor units and their mean discharge rate were compared for different sway velocities and positions. Motor unit discharges occurred more frequently when the body swayed faster and forward (Pearson R = 0.63; P < 0.0001). This higher likelihood of observing motor unit potentials was explained chiefly by the recruitment of additional units. During forward body shifts, the median number of units detected increased from 3 to 11 (P < 0.0001), whereas the discharge rate changed from 8 ± 1.1 (mean ± SD) to 10 ± 0.9 pulses/s (P = 0.001). Strikingly, motor units did not discharge continuously throughout standing. They were recruited within individual, forward sways and intermittently, with a modal rate of two recruitments per second. This modal rate is consistent with previous circumstantial evidence relating the control of standing to an intrinsic, higher level planning process.

  18. 7. SHEET 1, CONTROL HOUSE FOR DRY DOCK. United Engineering ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. SHEET 1, CONTROL HOUSE FOR DRY DOCK. United Engineering Company Ltd., Alameda Shipyard, Ship Repair Facilities, Office Building. Plans, elevations, sections, details. John Hudspeth, Architect, at foot of Main Street, Alameda, Calif. Sheet no. 1 of 2 sheets, Plan no. 10,507. Various scales. January 4, 1943, last revised 1/28/43. U.S. Navy, Bureau of Yards & Docks, Contract no. bs 76. Approved for construction October 9, 1943. blueprint - United Engineering Company Shipyard, Control House for Dry Dock, 2900 Main Street, Alameda, Alameda County, CA

  19. Hardware interface unit for control of shuttle RMS vibrations

    NASA Technical Reports Server (NTRS)

    Lindsay, Thomas S.; Hansen, Joseph M.; Manouchehri, Davoud; Forouhar, Kamran

    1994-01-01

    Vibration of the Shuttle Remote Manipulator System (RMS) increases the time for task completion and reduces task safety for manipulator-assisted operations. If the dynamics of the manipulator and the payload can be physically isolated, performance should improve. Rockwell has developed a self contained hardware unit which interfaces between a manipulator arm and payload. The End Point Control Unit (EPCU) is built and is being tested at Rockwell and at the Langley/Marshall Coupled, Multibody Spacecraft Control Research Facility in NASA's Marshall Space Flight Center in Huntsville, Alabama.

  20. 56. VIEW OF LAUNCHER FROM SOUTHWEST. NITROGEN CONTROL UNIT ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    56. VIEW OF LAUNCHER FROM SOUTHWEST. NITROGEN CONTROL UNIT ON RIGHT; UMBILICAL MAST ON LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. Infection control for SARS in a tertiary neonatal centre.

    PubMed

    Ng, P C; So, K W; Leung, T F; Cheng, F W T; Lyon, D J; Wong, W; Cheung, K L; Fung, K S C; Lee, C H; Li, A M; Hon, K L E; Li, C K; Fok, T F

    2003-09-01

    The Severe Acute Respiratory Syndrome (SARS) is a newly discovered infectious disease caused by a novel coronavirus, which can readily spread in the healthcare setting. A recent community outbreak in Hong Kong infected a significant number of pregnant women who subsequently required emergency caesarean section for deteriorating maternal condition and respiratory failure. As no neonatal clinician has any experience in looking after these high risk infants, stringent infection control measures for prevention of cross infection between patients and staff are important to safeguard the wellbeing of the work force and to avoid nosocomial spread of SARS within the neonatal unit. This article describes the infection control and patient triage policy of the neonatal unit at the Prince of Wales Hospital, Hong Kong. We hope this information is useful in helping other units to formulate their own infection control plans according to their own unit configuration and clinical needs.

  2. Locomotion of Amorphous Surface Robots

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T. (Inventor)

    2018-01-01

    An amorphous robot includes a compartmented bladder containing fluid, a valve assembly, and an outer layer encapsulating the bladder and valve assembly. The valve assembly draws fluid from a compartment(s) and discharges the drawn fluid into a designated compartment to displace the designated compartment with respect to the surface. Another embodiment includes elements each having a variable property, an outer layer that encapsulates the elements, and a control unit. The control unit energizes a designated element to change its variable property, thereby moving the designated element. The elements may be electromagnetic spheres with a variable polarity or shape memory polymers with changing shape and/or size. Yet another embodiment includes an elongated flexible tube filled with ferrofluid, a moveable electromagnet, an actuator, and a control unit. The control unit energizes the electromagnet and moves the electromagnet via the actuator to magnetize the ferrofluid and lengthen the flexible tube.

  3. Locomotion of Amorphous Surface Robots

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T. (Inventor)

    2016-01-01

    An amorphous robot includes a compartmented bladder containing fluid, a valve assembly, and an outer layer encapsulating the bladder and valve assembly. The valve assembly draws fluid from a compartment(s) and discharges the drawn fluid into a designated compartment to displace the designated compartment with respect to the surface. Another embodiment includes elements each having a variable property, an outer layer that encapsulates the elements, and a control unit. The control unit energizes a designated element to change its variable property, thereby moving the designated element. The elements may be electromagnetic spheres with a variable polarity or shape memory polymers with changing shape and/or size. Yet another embodiment includes an elongated flexible tube filled with ferrofluid, a moveable electromagnet, an actuator, and a control unit. The control unit energizes the electromagnet and moves the electromagnet via the actuator to magnetize the ferrofluid and lengthen the flexible tube.

  4. Locomotion of Amorphous Surface Robots

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T. (Inventor)

    2014-01-01

    An amorphous robot includes a compartmented bladder containing fluid, a valve assembly, and an outer layer encapsulating the bladder and valve assembly. The valve assembly draws fluid from a compartment(s) and discharges the drawn fluid into a designated compartment to displace the designated compartment with respect to the surface. Another embodiment includes elements each having a variable property, an outer layer that encapsulates the elements, and a control unit. The control unit energizes a designated element to change its variable property, thereby moving the designated element. The elements may be electromagnetic spheres with a variable polarity or shape memory polymers with changing shape and/or size. Yet another embodiment includes an elongated flexible tube filled with ferrofluid, a moveable electromagnet, an actuator, and a control unit. The control unit energizes the electromagnet and moves the electromagnet via the actuator to magnetize the ferrofluid and lengthen the flexible tube.

  5. Loss of control air at Browns Ferry Unit One: accident sequence analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrington, R.M.; Hodge, S.A.

    1986-04-01

    This study describes the predicted response of the Browns Ferry Nuclear Plant to a postulated complete failure of plant control air. The failure of plant control air cascades to include the loss of drywell control air at Units 1 and 2. Nevertheless, this is a benign accident unless compounded by simultaneous failures in the turbine-driven high pressure injection systems. Accident sequence calculations are presented for Loss of Control Air sequences with assumed failure upon demand of the Reactor Core Isolation Cooling (RCIC) and the High Pressure Coolant Injection (HPCI) at Unit 1. Sequences with and without operator action are considered.more » Results show that the operators can prevent core uncovery if they take action to utilize the Control Rod Drive Hydraulic System as a backup high pressure injection system.« less

  6. Research and development of the laser tracker measurement system

    NASA Astrophysics Data System (ADS)

    Zhang, Z. L.; Zhou, W. H.; Lao, D. B.; Yuan, J.; Dong, D. F. F.; Ji, R. Y. Y.

    2013-01-01

    The working principle and system design of the laser tracker measurement system are introduced, as well as the key technologies and solutions in the implementation of the system. The design and implementation of the hardware and configuration of the software are mainly researched. The components of the hardware include distance measuring unit, angle measuring unit, tracking and servo control unit and electronic control unit. The distance measuring devices include the relative distance measuring device (IFM) and the absolute distance measuring device (ADM). The main component of the angle measuring device, the precision rotating stage, is mainly comprised of the precision axis and the encoders which are both set in the tracking head. The data processing unit, tracking and control unit and power supply unit are all set in the control box. The software module is comprised of the communication module, calibration and error compensation module, data analysis module, database management module, 3D display module and the man-machine interface module. The prototype of the laser tracker system has been accomplished and experiments have been carried out to verify the proposed strategies of the hardware and software modules. The experiments showed that the IFM distance measuring error is within 0.15mm, the ADM distance measuring error is within 3.5mm and the angle measuring error is within 3" which demonstrates that the preliminary prototype can realize fundamental measurement tasks.

  7. Close-loop performance of a high precision deflectometry controlled deformable mirror (DCDM) unit for wavefront correction in adaptive optics system

    NASA Astrophysics Data System (ADS)

    Huang, Lei; Zhou, Chenlu; Zhao, Wenchuan; Choi, Heejoo; Graves, Logan; Kim, Daewook

    2017-06-01

    We present a high precision deflectometry system (DS) controlled deformable mirror (DM) solution for optical system. Different from wavefront and non-wavefront system, the DS and the DM are set to be an individual integrated DCDM unit and can be installed in one base plate. In the DCDM unit, the DS can directly provide the influence functions and surface shape of the DM to the industrial computer in any adaptive optics system. As an integrated adaptive unit, the DCDM unit could be put into various optical systems to realize aberration compensation. In this paper, the configuration and principle of the DCDM unit is introduced first. Theoretical simulation on the close-loop performance of the DCDM unit is carried out. Finally, a verification experiment is proposed to verify the compensation capability of the DCDM unit.

  8. 31 CFR 596.313 - United States person.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States person. 596.313 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TERRORISM LIST GOVERNMENTS SANCTIONS REGULATIONS General Definitions § 596.313 United States person. The term United States person means any United States...

  9. Short-pulse controlled optical switch using external cavity based single mode Fabry-Pérot laser diode.

    PubMed

    Nakarmi, Bikash; Hoai, Tran Quoc; Won, Yong-Hyub; Zhang, Xuping

    2014-06-30

    We propose and demonstrate a novel scheme for short pulse controlled all-optical switch using external cavity based single mode Fabry- Pérot laser diode (SMFP-LD). The proposed scheme consists of control unit and switching unit as two essential blocks. The basic principle of the proposed scheme is the optical bistability property of SMFP-LD for the control unit and the suppression of the dominant beam of SMFP-LD with injection locking for the switching unit. We also present the analysis of hysteresis width and rising/falling time with change in wavelength detuning which helps to find the optimum wavelength detuning value and power of light beams at different stages of the proposed scheme that gives wide input dynamic power range, high ON/OFF contrast ratio, and low rising/falling time. Input data of 10 Gb/s Non Return to Zero (NRZ) signal is switched at output ports depending upon the control signal generated by the control unit, which comprises of optical SR latch. Output waveforms, clear eye diagrams with extinction ratio of about 11 dB, rising/falling time of about 30 ps and 40 ps, and bit error rate (BER) are measured to validate proposed scheme. No noise floor is observed at output ports up to BER of 10-(12) and the maximum power penalty recorded is about 1.7 dB at a BER of 10-(9) which shows good performance of the proposed short pulse controlled optical switch using SMFP-LDs.

  10. Prosthetic urinary sphincter

    NASA Technical Reports Server (NTRS)

    Helms, C. R.; Smyly, H. M. (Inventor)

    1981-01-01

    A pump/valve unit for controlling the inflation and deflation of a urethral collar in a prosthetic urinary sphincter device is described. A compressible bulb pump defining a reservoir was integrated with a valve unit for implantation. The valve unit includes a movable valve member operable by depression of a flexible portion of the valve unit housing for controlling fluid flow between the reservoir and collar; and a pressure sensing means which operates the valve member to relieve an excess pressure in the collar should too much pressure be applied by the patient.

  11. 21 CFR 203.38 - Sample lot or control numbers; labeling of sample units.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sample lot or control numbers; labeling of sample units. 203.38 Section 203.38 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL PRESCRIPTION DRUG MARKETING Samples § 203.38 Sample lot or control...

  12. Engine Tune-up Service. Unit 6: Emission Control Systems. Posttests. Automotive Mechanics Curriculum.

    ERIC Educational Resources Information Center

    Morse, David T.; May, Theodore R.

    This book of posttests is designed to accompany the Engine Tune-Up Service Student Guide for Unit 6, Emission Control Systems, available separately as CE 031 220. Focus of the posttests is inspecting, testing, and servicing emission control systems. One multiple choice posttest is provided that covers the seven performance objectives contained in…

  13. Troubleshooting of an Electromechanical System (Westinghouse PLC Controlling a Pneumatic Robot). High-Technology Training Module.

    ERIC Educational Resources Information Center

    Tucker, James D.

    This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…

  14. 78 FR 42491 - Aluminum Extrusions from the People's Republic of China: Notice of Court Decision Not in Harmony...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-16

    ...'') imported by Valeo, Inc., Valeo Engine Cooling Inc., and Valeo Climate Control Corp. (collectively, ``Valeo..., Inc., and Valeo Climate Control Corp. v. United States, Court No. 12-00381 (CIT February 13, 2013).\\2... Remand, Valeo, Inc., Valeo Engine Cooling, Inc., and Valeo Climate Control Corp. v. United States, Court...

  15. 40 CFR 63.1575 - What reports must I submit and when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... cracking units that are served by a single wet scrubber emission control device (e.g., a Venturi scrubber... requirements applicable to the unit that is operating and the wet scrubber emission control device do not apply...

  16. 28. Credit JTL. Overview of unit 5 (installed 1908) showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. Credit JTL. Overview of unit 5 (installed 1908) showing exciter, generator, deflector motor, needle valve control, impulse wheel housing, and gate valve controls. - Battle Creek Hydroelectric System, Battle Creek & Tributaries, Red Bluff, Tehama County, CA

  17. Computer Controlled Microwave Oven System for Rapid Water Content Determination

    DTIC Science & Technology

    1988-11-01

    Codes - .d/or CONTENTS Page PREFACE .................................................................... 1 CONVERSION FACTORS, NON- SI TO SI (METRIC...CONVERSION FACTORS, NON- SI TO SI (METRIC) UNITS OF MEASUREMENT Non- SI units of measurement used in this report can be converted to SI (metric) units as...formula: C = (5/9)(F - 32) . To obtain Kelvin ( K ) readings, use: K = (5/9)(F - 32) + 273.15 3 COMPUTER CONTROLLED MICROWAVE OVEN SYSTEM FOR RAPID WATER

  18. Antenna unit and radio base station therewith

    DOEpatents

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  19. Advanced I&C for Fault-Tolerant Supervisory Control of Small Modular Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Daniel G.

    In this research, we have developed a supervisory control approach to enable automated control of SMRs. By design the supervisory control system has an hierarchical, interconnected, adaptive control architecture. A considerable advantage to this architecture is that it allows subsystems to communicate at different/finer granularity, facilitates monitoring of process at the modular and plant levels, and enables supervisory control. We have investigated the deployment of automation, monitoring, and data collection technologies to enable operation of multiple SMRs. Each unit's controller collects and transfers information from local loops and optimize that unit’s parameters. Information is passed from the each SMR unitmore » controller to the supervisory controller, which supervises the actions of SMR units and manage plant processes. The information processed at the supervisory level will provide operators the necessary information needed for reactor, unit, and plant operation. In conjunction with the supervisory effort, we have investigated techniques for fault-tolerant networks, over which information is transmitted between local loops and the supervisory controller to maintain a safe level of operational normalcy in the presence of anomalies. The fault-tolerance of the supervisory control architecture, the network that supports it, and the impact of fault-tolerance on multi-unit SMR plant control has been a second focus of this research. To this end, we have investigated the deployment of advanced automation, monitoring, and data collection and communications technologies to enable operation of multiple SMRs. We have created a fault-tolerant multi-unit SMR supervisory controller that collects and transfers information from local loops, supervise their actions, and adaptively optimize the controller parameters. The goal of this research has been to develop the methodologies and procedures for fault-tolerant supervisory control of small modular reactors. To achieve this goal, we have identified the following objectives. These objective are an ordered approach to the research: I) Development of a supervisory digital I&C system II) Fault-tolerance of the supervisory control architecture III) Automated decision making and online monitoring.« less

  20. 40 CFR 62.14575 - What must I do if I close my CISWI unit and then restart it?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... retrofit construction of control devices so that when the affected CISWI unit is brought online, all necessary process changes and air pollution control devices operate as designed. Waste Management Plan ...

  1. C-A4-01: Computerized Clinical Decision Support During Drug Ordering for Long-term Care Residents With Renal Insufficiency

    PubMed Central

    Field, Terry S; Rochon, Paula; Lee, Monica; Gavendo, Linda; Baril, Joann L; Gurwitz, Jerry H

    2010-01-01

    Objective: To determine whether a computerized clinical decision support system (CDSS) providing patient specific recommendations in real- time improves the quality of prescribing for long-term care residents with renal insufficiency. Design: A randomized trial within the long-stay units of a large long-term care facility. Randomization was within blocks by unit type. Alerts related to medication prescribing for residents with renal insufficiency were displayed to prescribers in the intervention units and hidden but tracked in control units. Measurement: The proportions of final drug orders that were appropriate were compared between intervention and control units within alert categories: recommended medication doses; recommended administration frequencies; recommendations to avoid the drug; 4) warnings of missing information. Results: The rates of alerts were nearly equal in the intervention and control units: 2.5 per 1000 resident days in the intervention units and 2.4 in the control units. The proportions of dose alerts for which the final drug orders were appropriate were similar between the intervention and control units (relative risk 0.95, 95% confidence interval 0.83, 1.1). For the remaining alert categories significantly higher proportions of final drug orders were appropriate in the intervention units: relative risk 2.4 for maximum frequency (1.4, 4.4); 2.6 for drugs that should be avoided (1.4, 5.0); and 1.8 for alerts to acquire missing information (1.1, 3.4). Overall, final drug orders were appropriate significantly more often than a relative risk 1.2 (1.0, 1.4). By tracking personnel time and expenditures, we estimated the cost of developing the CDSS as $48,668.57. Drug costs saved during the 12 months of the trial are estimated at $2,137. Conclusion: Clinical decision support for physicians prescribing medications for long-term care residents with renal insufficiency can improve the quality of prescribing decisions. However, patient well-being and quality of care rather than the business case related to cost savings are likely to be the key drivers for adoption of this HIT application.

  2. Actuator digital interface unit (AIU). [control units for space shuttle data system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Alternate versions of the actuator interface unit are presented. One alternate is a dual-failure immune configuration which feeds a look-and-switch dual-failure immune hydraulic system. The other alternate is a single-failure immune configuration which feeds a majority voting hydraulic system. Both systems communicate with the data bus through data terminals dedicated to each user subsystem. Both operational control data and configuration control information are processed in and out of the subsystem via the data terminal which yields the actuator interface subsystem, self-managing within its failure immunity capability.

  3. Development of Protection and Control Unit for Distribution Substation

    NASA Astrophysics Data System (ADS)

    Iguchi, Fumiaki; Hayashi, Hideyuki; Takeuchi, Motohiro; Kido, Mitsuyasu; Kobayashi, Takashi; Yanaoka, Atsushi

    The Recently, electronics and IT technologies have been rapidly innovated and have been introduced to power system protection & control system to achieve high reliability, maintainability and more functionality. Concerning the distribution substation application, digital relays have been applied for more than 10 years. Because of a number of electronic devices used for it, product cost becomes higher. Also, products installed during the past high-growth period will be at the end of lifetime and will be replaced. Therefore, replacing market is expected to grow and the reduction of cost is demanded. Considering above mentioned background, second generation digital protection and control unit as a successor is designed to have following concepts. Functional integration based on advanced digital technologies, Ethernet LAN based indoor communication network, cost reduction and downsizing. Pondering above concepts, integration of protection and control function is adopted in contrary to the functional segregation applied to the previous system in order to achieve one-unit concept. Also the adoption of Ethernet LAN for inter-unit communication is objective. This report shows the development of second-generation digital relay for distribution substation, which is equipped with control function and Ethernet LAN by reducing the size of auxiliary transformer unit and the same size as previous product is realized.

  4. A randomized controlled trial oftransfusion-related acute lung injury: is plasma from multiparous blood donors dangerous?

    PubMed

    Palfi, M; Berg, S; Ernerudh, J; Berlin, G

    2001-03-01

    Transfusion-related acute lung injury (TRALI) and other posttransfusion reactions may be caused by granulocyte and/or HLA antibodies, which are often present in blood from multiparous donors. The purpose of this study was to compare the effects of plasma from multiparous donors with those of plasma from donors with no history of transfusion or pregnancy (control plasma) in a prospective, randomized, double-blind, crossover study. Intensive care patients, judged to need at least 2 units of plasma, were randomly assigned to receive a unit of control plasma and, 4 hours later, a plasma unit from a multiparous donor (> or = 3 live births) or to receive the plasma units in opposite order. The patients were closely monitored, and body temperature, blood pressure, and heart rate were recorded. Blood samples for analysis of blood gases, TNFalpha, IL-1 receptor antagonist, soluble E selectin, and C3d complement factor were collected at least on four occasions (before and after the transfusion of each unit). Transfusion of plasma from multiparous donors was associated with significantly lower oxygen saturation and higher TNFalpha concentrations than transfusion of control plasma. The mean arterial pressure increased significantly after the transfusion of control plasma, whereas plasma from multiparous donors had no effect on it. Five posttransfusion reactions were observed in 100 patients, in four cases after the transfusion of plasma from multiparous donors. Plasma from multiparous blood donors may impair pulmonary function in intensive care unit patients.

  5. Nonlinear adaptive control of grid-connected three-phase inverters for renewable energy applications

    NASA Astrophysics Data System (ADS)

    Mahdian-Dehkordi, N.; Namvar, M.; Karimi, H.; Piya, P.; Karimi-Ghartemani, M.

    2017-01-01

    Distributed generation (DG) units are often interfaced to the main grid using power electronic converters including voltage-source converters (VSCs). A VSC offers dc/ac power conversion, high controllability, and fast dynamic response. Because of nonlinearities, uncertainties, and system parameters' changes involved in the nature of a grid-connected renewable DG system, conventional linear control methods cannot completely and efficiently address all control objectives. In this paper, a nonlinear adaptive control scheme based on adaptive backstepping strategy is presented to control the operation of a grid-connected renewable DG unit. As compared to the popular vector control technique, the proposed controller offers smoother transient responses, and lower level of current distortions. The Lyapunov approach is used to establish global asymptotic stability of the proposed control system. Linearisation technique is employed to develop guidelines for parameters tuning of the controller. Extensive time-domain digital simulations are performed and presented to verify the performance of the proposed controller when employed in a VSC to control the operation of a two-stage DG unit and also that of a single-stage solar photovoltaic system. Desirable and superior performance of the proposed controller is observed.

  6. Engine Tune-up Service. Unit 6: Emission Control Systems. Review Exercise Book. Automotive Mechanics Curriculum.

    ERIC Educational Resources Information Center

    Bacon, E. Miles

    This book of pretests and review exercises is designed to accompany the Engine Tune-Up Service Student Guide for Unit 6, Emission Control Systems, available separately as CE 031 220. Focus of the exercises and pretests is inspecting, testing, and servicing emission control systems. Pretests and performance checklists are provided for each of the…

  7. The Role of Parents' Control in Early Adolescents' Psychological Functioning: A Longitudinal Investigation in the United States and China

    ERIC Educational Resources Information Center

    Wang, Qian; Pomerantz, Eva M.; Chen, Huichang

    2007-01-01

    This research compared the effects over time of parents' control and autonomy support on children's functioning in the United States and China. American and Chinese (N = 806) seventh graders (mean age = 12.73 years) participated in a 6-month longitudinal study. Children reported on their parents' psychological control, psychological autonomy…

  8. 40 CFR 96.387 - Change in regulatory status.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Season unit) under § 96.342 for the control period multiplied by; (B) The ratio of the number of days, in... the same or a prior control period as: (A) Any CAIR NOX Ozone Season allowances allocated to the CAIR NOX Ozone Season opt-in unit under § 96.388 for any control period after the date on which the CAIR...

  9. Assessing the influence of component processing and donor characteristics on quality of red cell concentrates using quality control data.

    PubMed

    Jordan, A; Chen, D; Yi, Q-L; Kanias, T; Gladwin, M T; Acker, J P

    2016-07-01

    Quality control (QC) data collected by blood services are used to monitor production and to ensure compliance with regulatory standards. We demonstrate how analysis of quality control data can be used to highlight the sources of variability within red cell concentrates (RCCs). We merged Canadian Blood Services QC data with manufacturing and donor records for 28 227 RCC between June 2011 and October 2014. Units were categorized based on processing method, bag manufacturer, donor age and donor sex, then assessed based on product characteristics: haemolysis and haemoglobin levels, unit volume, leucocyte count and haematocrit. Buffy-coat method (top/bottom)-processed units exhibited lower haemolysis than units processed using the whole-blood filtration method (top/top). Units from female donors exhibited lower haemolysis than male donations. Processing method influenced unit volume and the ratio of additive solution to residual plasma. Stored red blood cell characteristics are influenced by prestorage processing and donor factors. Understanding the relationship between processing, donors and RCC quality will help blood services to ensure the safety of transfused products. © 2016 International Society of Blood Transfusion.

  10. Statistical transformation and the interpretation of inpatient glucose control data from the intensive care unit.

    PubMed

    Saulnier, George E; Castro, Janna C; Cook, Curtiss B

    2014-05-01

    Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box-Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. © 2014 Diabetes Technology Society.

  11. Statistical Transformation and the Interpretation of Inpatient Glucose Control Data From the Intensive Care Unit

    PubMed Central

    Saulnier, George E.; Castro, Janna C.

    2014-01-01

    Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box–Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. PMID:24876620

  12. Charge-Control Unit for Testing Lithium-Ion Cells

    NASA Technical Reports Server (NTRS)

    Reid, Concha M.; Mazo, Michelle A.; Button, Robert M.

    2008-01-01

    A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.

  13. Effect of pain on the modulation in discharge rate of sternocleidomastoid motor units with force direction.

    PubMed

    Falla, Deborah; Lindstrøm, Rene; Rechter, Lotte; Farina, Dario

    2010-05-01

    To compare the behavior of sternocleidomastoid motor units of patients with chronic neck pain and healthy controls. Nine women (age, 40.4+/-3.5 yr) with chronic neck pain and nine age- and gender-matched healthy controls participated. Surface and intramuscular EMG were recorded from the sternocleidomastoid muscle bilaterally as subjects performed isometric contractions of 10-s duration in the horizontal plane at a force of 15 N in eight directions (0-360 degrees ; 45 degrees intervals) and isometric contractions at 15 and 30 N force with continuous change in force direction in the range 0-360 degrees . Motor unit behavior was monitored during the 10-s contractions and the subsequent resting periods. The mean motor unit discharge rate depended on the direction of force in the control subjects (P<0.05) but not in the patients. Moreover, in three of the nine patients, but in none of the controls, single motor unit activity continued for 8.1+/-6.1s upon completion of the contraction. The surface EMG amplitude during the circular contraction at 15N was greater for the patients (43.5+/-54.2 microV) compared to controls (16.9+/-14.9 microV; P<0.05). The modulation in discharge rate of individual motor units with force direction is reduced in the sternocleidomastoid muscle in patients with neck pain, with some patients showing prolonged motor unit activity when they were instructed to rest. These observations suggest that chronic neck pain affects the change in neural drive to muscles with force direction. Copyright 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Turbine Powered Simulator Calibration and Testing for Hybrid Wing Body Powered Airframe Integration

    NASA Technical Reports Server (NTRS)

    Shea, Patrick R.; Flamm, Jeffrey D.; Long, Kurtis R.; James, Kevin D.; Tompkins, Daniel M.; Beyar, Michael D.

    2016-01-01

    Propulsion airframe integration testing on a 5.75% scale hybrid wing body model us- ing turbine powered simulators was completed at the National Full-Scale Aerodynamics Complex 40- by 80-foot test section. Four rear control surface con gurations including a no control surface de ection con guration were tested with the turbine powered simulator units to investigate how the jet exhaust in uenced the control surface performance as re- lated to the resultant forces and moments on the model. Compared to ow-through nacelle testing on the same hybrid wing body model, the control surface e ectiveness was found to increase with the turbine powered simulator units operating. This was true for pitching moment, lift, and drag although pitching moment was the parameter of greatest interest for this project. With the turbine powered simulator units operating, the model pitching moment was seen to increase when compared to the ow-through nacelle con guration indicating that the center elevon and vertical tail control authority increased with the jet exhaust from the turbine powered simulator units.

  15. 78 FR 45842 - Airworthiness Directives; CFM International, S. A. Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-30

    ... of the delta-P valve in the hydro-mechanical unit (HMU) fuel control caused by exposure to type TS-1... hydro- mechanical unit (HMU) fuel control part numbers (P/Ns) in paragraphs (c)(1) and (c)(2) of this AD...

  16. MANIPULATOR FOR SLAVE ROBOT

    DOEpatents

    Goertz, R.C.; Grimson, J.H.; Kohut, F.A.

    1961-04-01

    A remote-control manipulator comprising two stationary master units, two slave units on a movable vehicle, and electrical connections between the master and slave units is reported. The slave units are side by side with a minimum over-all width, which is made feasible by an arrangement of transducers producing most movements of each slave unit to one side of the support of said slave unit.

  17. Design of a microprocessor-based Control, Interface and Monitoring (CIM unit for turbine engine controls research

    NASA Technical Reports Server (NTRS)

    Delaat, J. C.; Soeder, J. F.

    1983-01-01

    High speed minicomputers were used in the past to implement advanced digital control algorithms for turbine engines. These minicomputers are typically large and expensive. It is desirable for a number of reasons to use microprocessor-based systems for future controls research. They are relatively compact, inexpensive, and are representative of the hardware that would be used for actual engine-mounted controls. The Control, Interface, and Monitoring Unit (CIM) contains a microprocessor-based controls computer, necessary interface hardware and a system to monitor while it is running an engine. It is presently being used to evaluate an advanced turbofan engine control algorithm.

  18. Unit bias. A new heuristic that helps explain the effect of portion size on food intake.

    PubMed

    Geier, Andrew B; Rozin, Paul; Doros, Gheorghe

    2006-06-01

    People seem to think that a unit of some entity (with certain constraints) is the appropriate and optimal amount. We refer to this heuristic as unit bias. We illustrate unit bias by demonstrating large effects of unit segmentation, a form of portion control, on food intake. Thus, people choose, and presumably eat, much greater weights of Tootsie Rolls and pretzels when offered a large as opposed to a small unit size (and given the option of taking as many units as they choose at no monetary cost). Additionally, they consume substantially more M&M's when the candies are offered with a large as opposed to a small spoon (again with no limits as to the number of spoonfuls to be taken). We propose that unit bias explains why small portion sizes are effective in controlling consumption; in some cases, people served small portions would simply eat additional portions if it were not for unit bias. We argue that unit bias is a general feature in human choice and discuss possible origins of this bias, including consumption norms.

  19. 40 CFR 63.1281 - Control equipment requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dehydration unit baseline operations (as defined in § 63.1271). Records of glycol dehydration unit baseline... the Administrator's satisfaction, the conditions for which glycol dehydration unit baseline operations... emission reduction of 95.0 percent for the glycol dehydration unit process vent. Only modifications in...

  20. 40 CFR 63.1281 - Control equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dehydration unit baseline operations (as defined in § 63.1271). Records of glycol dehydration unit baseline... the Administrator's satisfaction, the conditions for which glycol dehydration unit baseline operations... emission reduction of 95.0 percent for the glycol dehydration unit process vent. Only modifications in...

  1. Decentralizing Centralized Control: Reorienting a Fundamental Tenet for Resilient Air Operation

    DTIC Science & Technology

    2008-05-22

    Forward Air Controller FBIS Foreign Broadcast Information Service FCC Functional Component Commander FM Field Manual GBU - 39 Guided Bomb Unit - 39...Diameter Bomb ( GBU - 39 ) TEG Test and Evaluation Group TST Time Sensitive Target UAV Unmanned Aerial Vehicle USAF United States Air Force USAFWS United...www.afmc.af.mil/news/story.asp?id=123017916 (accessed November 11, 2007). Recent fielding of the GBU - 39 , Small Diameter Bomb (SDB), enables a

  2. Automatic insulation resistance testing apparatus

    DOEpatents

    Wyant, Francis J.; Nowlen, Steven P.; Luker, Spencer M.

    2005-06-14

    An apparatus and method for automatic measurement of insulation resistances of a multi-conductor cable. In one embodiment of the invention, the apparatus comprises a power supply source, an input measuring means, an output measuring means, a plurality of input relay controlled contacts, a plurality of output relay controlled contacts, a relay controller and a computer. In another embodiment of the invention the apparatus comprises a power supply source, an input measuring means, an output measuring means, an input switching unit, an output switching unit and a control unit/data logger. Embodiments of the apparatus of the invention may also incorporate cable fire testing means. The apparatus and methods of the present invention use either voltage or current for input and output measured variables.

  3. Architecture and data processing alternatives for Tse computer. Volume 1: Tse logic design concepts and the development of image processing machine architectures

    NASA Technical Reports Server (NTRS)

    Rickard, D. A.; Bodenheimer, R. E.

    1976-01-01

    Digital computer components which perform two dimensional array logic operations (Tse logic) on binary data arrays are described. The properties of Golay transforms which make them useful in image processing are reviewed, and several architectures for Golay transform processors are presented with emphasis on the skeletonizing algorithm. Conventional logic control units developed for the Golay transform processors are described. One is a unique microprogrammable control unit that uses a microprocessor to control the Tse computer. The remaining control units are based on programmable logic arrays. Performance criteria are established and utilized to compare the various Golay transform machines developed. A critique of Tse logic is presented, and recommendations for additional research are included.

  4. Accreditation of specialized asthma units for adults in Spain: an applicable experience for the management of difficult-to-control asthma

    PubMed Central

    Cisneros, Carolina; Díaz-Campos, Rocío Magdalena; Marina, Núria; Melero, Carlos; Padilla, Alicia; Pascual, Silvia; Pinedo, Celia; Trisán, Andrea

    2017-01-01

    This paper, developed by consensus of staff physicians of accredited asthma units for the management of severe asthma, presents information on the process and requirements for already-existing asthma units to achieve official accreditation by the Spanish Society of Pneumology and Thoracic Surgery (SEPAR). Three levels of specialized asthma care have been established based on available resources, which include specialized units for highly complex asthma, specialized asthma units, and basic asthma units. Regardless of the level of accreditation obtained, the distinction of “excellence” could be granted when more requirements in the areas of provision of care, technical and human resources, training in asthma, and teaching and research activities were met at each level. The Spanish experience in the process of accreditation of specialized asthma units, particularly for the care of patients with difficult-to-control asthma, may be applicable to other health care settings. PMID:28533690

  5. Urine output on an intensive care unit: case-control study.

    PubMed

    Solomon, Anthony W; Kirwan, Christopher J; Alexander, Neal D E; Nimako, Kofi; Jurukov, Angela; Forth, Rebecca J; Rahman, Tony M

    2010-12-14

    To compare urine output between junior doctors in an intensive care unit and the patients for whom they are responsible. Case-control study. General intensive care unit in a tertiary referral hospital. 18 junior doctors responsible for clerking patients on weekday day shifts in the unit from 23 March to 23 April 2009 volunteered as "cases." Controls were the patients in the unit clerked by those doctors. Exclusion criteria (for both groups) were pregnancy, baseline estimated glomerular filtration rate <15 ml/min/1.73 m(2), and renal replacement therapy. Oliguria (defined as mean urine output <0.5 ml/kg/hour over six or more hours of measurement) and urine output (in ml/kg/hour) as a continuous variable. Doctors were classed as oliguric and "at risk" of acute kidney injury on 19 (22%) of 87 shifts in which urine output was measured, and oliguric to the point of being "in injury" on one (1%) further shift. Data were available for 208 of 209 controls matched to cases in the data collection period; 13 of these were excluded because the control was receiving renal replacement therapy. Doctors were more likely to be oliguric than their patients (odds ratio 1.99, 95% confidence interval 1.08 to 3.68, P=0.03). For each additional 1 ml/kg/hour mean urine output, the odds ratio for being a case rather than a control was 0.27 (0.12 to 0.58, P=0.001). Mortality among doctors was astonishingly low, at 0% (0% to 18%). Managing our own fluid balance is more difficult than managing it in our patients. We should drink more water. Modifications to the criteria for acute kidney injury could be needed for the assessment of junior doctors in an intensive care unit.

  6. Stress among nurses working in emergency, anesthesiology and intensive care units depends on qualification: a Job Demand-Control survey.

    PubMed

    Trousselard, Marion; Dutheil, Frédéric; Naughton, Geraldine; Cosserant, Sylvie; Amadon, Sylvie; Dualé, Christian; Schoeffler, Pierre

    2016-02-01

    The nurse stress literature reports an overwhelming culture of acceptance and expectation of work stressors, ironically linked to the control of the workplace to effectively and proactively manage stress. The stressors involved in delivering "stress management" have been well studied in nursing-related workplaces, especially in acute care settings in accordance with the Karasek Job Demand-Control-Support (JDCS) model. However, little is known about the effects of specificity of an acute care unit and the level of qualifications on stress experienced by nurses. A survey using the JDCS model was conducted among 385 nurses working in three different acute care units (anesthesiology, emergency and intensive care unit) from a university hospital. Specific questions explored variables such as gender, acute care units, level of qualification and working experience. Two hundred questionnaires were returned. A high level of job strain was highlighted without a gender effect and in the absence of isostrain. Nurses from acute care units were located in the high stress quadrant of the JDCS model. Conversely, other nurses were commonly located in the "active" quadrant. Independent of acute care settings, the highest level of education was associated with the highest job strain and the lowest level of control. In an acute care setting, a high level of education was a key factor for high job stress and was associated with a perception of a low control in the workplace, both of which may be predictors of adverse mental health. In particular, the lack of control has been associated with moral distress, a frequently reported characteristic of acute care settings. To enhance the personal and professional outcomes of the advanced registered nurses, strategies for supporting nurses manage daily stressors in acute care are urgently required.

  7. Global Radius of Curvature Estimation and Control System for Segmented Mirrors

    NASA Technical Reports Server (NTRS)

    Rakoczy, John M. (Inventor)

    2006-01-01

    An apparatus controls positions of plural mirror segments in a segmented mirror with an edge sensor system and a controller. Current mirror segment edge sensor measurements and edge sensor reference measurements are compared with calculated edge sensor bias measurements representing a global radius of curvature. Accumulated prior actuator commands output from an edge sensor control unit are combined with an estimator matrix to form the edge sensor bias measurements. An optimal control matrix unit then accumulates the plurality of edge sensor error signals calculated by the summation unit and outputs the corresponding plurality of actuator commands. The plural mirror actuators respond to the actuator commands by moving respective positions of the mixor segments. A predetermined number of boundary conditions, corresponding to a plurality of hexagonal mirror locations, are removed to afford mathematical matrix calculation.

  8. Electric auxiliary power unit for Shuttle evolution

    NASA Technical Reports Server (NTRS)

    Meyer, Doug; Weber, Kent; Scott, Walter

    1989-01-01

    The Space Shuttle Orbiter currently uses three hydrazine fueled auxiliary power units (APUs) to provide hydraulic power for the vehicle aerodynamic surface controls, main engine thrust vector control, landing gear, steering, and brakes. Electric auxiliary power units have been proposed as possible replacements to the hydrazine auxiliary power units. Along with the potential advantages, this paper describes an Electric APU configuration and addresses the technical issues and risks associated with the subsystem components. Additionally, characteristics of an Electric APU compared to the existing APU and the direction of future study with respect to the Electric APU is suggested.

  9. Peak expiratory flow rate of children working in lock factories.

    PubMed

    Singhal, S; Singhal, A; Singh, P N; Agarwal, D K; Gulati, R

    2006-01-01

    Peak expiratory flow rate (PEFR) of 106 children working in different units of lock factory was measured and compared with age and sex matched control group of same socio-economic status children. All the children worked for about ten hours per day. It was observed that there was a significant decrease in PEFR of children working in the different units of lock factories i.e. Hand press, Polishing, Lock fitting, Lock packing units as compared to control group (P>0.001). The reduction percentage of PEFR was maximum in children working in polishing unit (25.48%).

  10. Modified high-intensity interval training reduces liver fat and improves cardiac function in non-alcoholic fatty liver disease: a randomized controlled trial.

    PubMed

    Hallsworth, Kate; Thoma, Christian; Hollingsworth, Kieren G; Cassidy, Sophie; Anstee, Quentin M; Day, Christopher P; Trenell, Michael I

    2015-12-01

    Although lifestyle changes encompassing weight loss and exercise remain the cornerstone of non-alcoholic fatty liver disease (NAFLD) management, the effect of different types of exercise on NAFLD is unknown. This study defines the effect of modified high-intensity interval training (HIIT) on liver fat, cardiac function and metabolic control in adults with NAFLD. Twenty-three patients with NAFLD [age 54±10 years, body mass index (BMI) 31±4 kg/m(2), intra-hepatic lipid >5%) were assigned to either 12 weeks HIIT or standard care (controls). HIIT involved thrice weekly cycle ergometry for 30-40 min. MRI and spectroscopy were used to assess liver fat, abdominal fat and cardiac structure/function/energetics. Glucose control was assessed by oral glucose tolerance test and body composition by air displacement plethysmography. Relative to control, HIIT decreased liver fat (11±5% to 8±2% compared with 10±4% to 10±4% P=0.019), whole-body fat mass (35±7 kg to 33±8 kg compared with 31±9 kg to 32±9 kg, P=0.013), alanine (52±29 units/l to 42±20 units/l compared with 47±22 units/l to 51±24 units/l, P=0.016) and aspartate aminotransferase (AST; 36±18 units/l to 33±15 units/l compared with 31±8 units/l to 35±8 units/l, P=0.017) and increased early diastolic filling rate (244±84 ml/s to 302±107 ml/s compared with 255±82 ml/s to 251±82 ml/s, P=0.018). There were no between groups differences in glucose control. Modified HIIT reduces liver fat and improves body composition alongside benefits to cardiac function in patients with NAFLD and should be considered as part of the broader treatment regimen by clinical care teams. ISRCTN trial ID: ISRCTN78698481. © 2015 Authors; published by Portland Press Limited.

  11. The effect of infection-control barriers on the light intensity of light-cure units and depth of cure of composite.

    PubMed

    Hodson, Nicholas A; Dunne, Stephen M; Pankhurst, Caroline L

    2005-04-01

    Dental curing lights are vulnerable to contamination with oral fluids during routine intra-oral use. This controlled study aimed to evaluate whether or not disposable transparent barriers placed over the light-guide tip would affect light output intensity or the subsequent depth of cure of a composite restoration. The impact on light intensity emitted from high-, medium- and low-output light-cure units in the presence of two commercially available disposable infection-control barriers was evaluated against a no-barrier control. Power density measurements from the three intensity light-cure units were recorded with a radiometer, then converted to a digital image using an intra-oral camera and values determined using a commercial computer program. For each curing unit, the measurements were repeated on ten separate occasions with each barrier and the control. Depth of cure was evaluated using a scrape test in a natural tooth model. At each level of light output, the two disposable barriers produced a significant reduction in the mean power density readings compared to the no-barrier control (P<0.005). The cure sleeve inhibited light output to a greater extent than either the cling film or the control (P<0.005). Only composite restorations light-activated by the high level unit demonstrated a small but significant decrease in the depth of cure compared to the control (P<0.05). Placing disposable barriers over the light-guide tip reduced the light intensity from all three curing lights. There was no impact on depth of cure except for the high-output light, where a small decrease in cure depth was noted but this was not considered clinically significant. Disposable barriers can be recommended for use with light-cure lights.

  12. Goal-directed control with cortical units that are gated by both top-down feedback and oscillatory coherence.

    PubMed

    Kerr, Robert R; Grayden, David B; Thomas, Doreen A; Gilson, Matthieu; Burkitt, Anthony N

    2014-01-01

    The brain is able to flexibly select behaviors that adapt to both its environment and its present goals. This cognitive control is understood to occur within the hierarchy of the cortex and relies strongly on the prefrontal and premotor cortices, which sit at the top of this hierarchy. Pyramidal neurons, the principal neurons in the cortex, have been observed to exhibit much stronger responses when they receive inputs at their soma/basal dendrites that are coincident with inputs at their apical dendrites. This corresponds to inputs from both lower-order regions (feedforward) and higher-order regions (feedback), respectively. In addition to this, coherence between oscillations, such as gamma oscillations, in different neuronal groups has been proposed to modulate and route communication in the brain. In this paper, we develop a simple, but novel, neural mass model in which cortical units (or ensembles) exhibit gamma oscillations when they receive coherent oscillatory inputs from both feedforward and feedback connections. By forming these units into circuits that can perform logic operations, we identify the different ways in which operations can be initiated and manipulated by top-down feedback. We demonstrate that more sophisticated and flexible top-down control is possible when the gain of units is modulated by not only top-down feedback but by coherence between the activities of the oscillating units. With these types of units, it is possible to not only add units to, or remove units from, a higher-level unit's logic operation using top-down feedback, but also to modify the type of role that a unit plays in the operation. Finally, we explore how different network properties affect top-down control and processing in large networks. Based on this, we make predictions about the likely connectivities between certain brain regions that have been experimentally observed to be involved in goal-directed behavior and top-down attention.

  13. Goal-directed control with cortical units that are gated by both top-down feedback and oscillatory coherence

    PubMed Central

    Kerr, Robert R.; Grayden, David B.; Thomas, Doreen A.; Gilson, Matthieu; Burkitt, Anthony N.

    2014-01-01

    The brain is able to flexibly select behaviors that adapt to both its environment and its present goals. This cognitive control is understood to occur within the hierarchy of the cortex and relies strongly on the prefrontal and premotor cortices, which sit at the top of this hierarchy. Pyramidal neurons, the principal neurons in the cortex, have been observed to exhibit much stronger responses when they receive inputs at their soma/basal dendrites that are coincident with inputs at their apical dendrites. This corresponds to inputs from both lower-order regions (feedforward) and higher-order regions (feedback), respectively. In addition to this, coherence between oscillations, such as gamma oscillations, in different neuronal groups has been proposed to modulate and route communication in the brain. In this paper, we develop a simple, but novel, neural mass model in which cortical units (or ensembles) exhibit gamma oscillations when they receive coherent oscillatory inputs from both feedforward and feedback connections. By forming these units into circuits that can perform logic operations, we identify the different ways in which operations can be initiated and manipulated by top-down feedback. We demonstrate that more sophisticated and flexible top-down control is possible when the gain of units is modulated by not only top-down feedback but by coherence between the activities of the oscillating units. With these types of units, it is possible to not only add units to, or remove units from, a higher-level unit's logic operation using top-down feedback, but also to modify the type of role that a unit plays in the operation. Finally, we explore how different network properties affect top-down control and processing in large networks. Based on this, we make predictions about the likely connectivities between certain brain regions that have been experimentally observed to be involved in goal-directed behavior and top-down attention. PMID:25152715

  14. Automotive Emission Control.

    ERIC Educational Resources Information Center

    Lee, Billy D.; And Others

    This publication contains instructional materials for both teachers and students for a course in automotive emission control. Instructional materials in this publication are written in terms of student performance using measurable objectives. The course includes 16 units. Each instructional unit includes some or all of the basic components of a…

  15. Stationary Engineering, Environmental Control, Refrigeration. Science Manual I.

    ERIC Educational Resources Information Center

    Steingress, Frederick M.; And Others

    The student materials present lessons about occupations related to environmental control, stationary engineering, and refrigeration. Included are 18 units organized by objective, information, reference, procedure, and assignment. Each lesson involves concrete trade experience where science is applied. Unit titles are: safety and housekeeping,…

  16. 40 CFR 63.2250 - What are the general requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., except during periods of process unit or control device startup, shutdown, and malfunction; prior to process unit initial startup; and during the routine control device maintenance exemption specified in... practice requirements are not operating, or during periods of startup, shutdown, and malfunction. Startup...

  17. 40 CFR 63.2250 - What are the general requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., except during periods of process unit or control device startup, shutdown, and malfunction; prior to process unit initial startup; and during the routine control device maintenance exemption specified in... practice requirements are not operating, or during periods of startup, shutdown, and malfunction. Startup...

  18. 40 CFR 63.2250 - What are the general requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., except during periods of process unit or control device startup, shutdown, and malfunction; prior to process unit initial startup; and during the routine control device maintenance exemption specified in... practice requirements are not operating, or during periods of startup, shutdown, and malfunction. Startup...

  19. Automotive Emission Control.

    ERIC Educational Resources Information Center

    Lee, Billy D.; Ragazzi, Ronald

    This guide designed to assist teachers in improving instruction in the area of automotive emission control curriculum includes four areas. Each area consists of one or more units of instruction, with each instructional unit including some or all of the following basic components: Performance objectives, suggested activities for teacher and…

  20. [Improvement of controlling system by a separated medical unit of special purpose].

    PubMed

    Shelepov, A M; Savchenko, I F; Zhidik, V V; Gogolevskiĭ, A S

    2009-11-01

    The article presents a variant securing of field treatment institutes by mobile command points in combination with creation of automated system of control of a separated medical unit of special purpose and improvement of communications devices, computing and relaying of data. Such improvement of system of control permits to solve governmental tasks and make decision more effective, spending less time.

  1. The Career Locus of Control Scale for Adolescents: Further Evidence of Validity in the United States

    ERIC Educational Resources Information Center

    Perry, Justin C.; Liu, Xiongyi; Griffin, Grant C.

    2011-01-01

    This study examined the construct validity of the Career Locus of Control Scale (CLCS) among diverse urban youth within the United States (N = 308). Confirmatory factor analyses verified two of the three models as acceptable fits. Two new models were also explored. Model 5 (Internality, Luck, and Non-Control), which was one of the new models, was…

  2. Crisis-Expectant Planning for Crisis Relocation.

    DTIC Science & Technology

    1981-10-01

    WORK UNIT NUmBERS Human Sciences Research, Inc. 7710 Old Springhouse Road Work Unit 482 1G McLean, Virginia 22102 It. CONTROLLING OFFICE NAME AND... Controlling Office) UNCLASSUIFIEDS.(1 ereot I Sm. DECLASSIFICATION/DOWNGRADING SCHEDULE 16. DISTRIBUTION STATE64ENT (of &hs .1. oer) Approved for Pttblic...preattack relocation period. 4. Improved population control with respect to orchestrating or phasing the evacuation movement, the post-evacuation

  3. Emergency Warning Systems. Part 2. Warning Systems - Evaluation Guidelines.

    DTIC Science & Technology

    1983-07-01

    ELEMENT. PROJECT. TASK AREA A WORK UNIT NUMBERS PRC Voorhees Work Unit 2234G 1500 Planning Research Drive McLean, Virginia 22102 ___ 11. CONTROLLING ...different from Controlling Office) IS. SECURITY CLASS. (of this report) Unclassified 15a. DECLASSIFICATION/DOWNGRADING SCHEDULE 16. DISTRIBUTION...systems that control these warning systems are discussed. Test results of several warning systems are included along with a discussion of sound

  4. ION SWITCH

    DOEpatents

    Cook, B.

    1959-02-10

    An ion switch capable of transferring large magnitudes of power is described. An ion switch constructed in accordance with the invention includes a pair of spaced control electrodes disposed in a highly evacuated region for connection in a conventional circuit to control the passing of power therethrough. A controllable ionic conduction path is provided directiy between the control electrodes by a source unit to close the ion switch. Conventional power supply means are provided to trigger the source unit and control the magnitude, durations and pulse repetition rate of the aforementioned ionic conduction path.

  5. [Prompt control of an imported carbapenem-resistant Acinetobacter baumanii outbreak in a French intensive care unit].

    PubMed

    Guth, C; Cavalli, Z; Pernod, C; Lhopital, C; Wey, Pf; Gerome, P; Turc, J

    2016-01-01

    to describe the management and control of a limited outbreak of carbapenem-resistant Acinetobacter baumanii (CRAB) outbreak in a French intensive care unit. Careful review of the contact's and carrier's files and outbreak management procedures. An undiagnosed CRAB carrier was admitted to our intensive care unit after medical evacuation from Turkey. Despite preventive isolation and contact precautions, a secondary case was diagnosed 5 days after admission of the index case and resulted in the creation of a crisis unit. Prompt management included an epidemiologic investigation with contact screening and follow-up, environmental screening, and additional restrictive measures: isolation room, closure of adjacent rooms, patient cohorting with designated nurses, and reinforcement of contact precautions. restrictive management of CRAB outbreaks may allow prompt outbreak control and avoid prolonged room closures.

  6. Design and realization of an active SAR calibrator for TerraSAR-X

    NASA Astrophysics Data System (ADS)

    Dummer, Georg; Lenz, Rainer; Lutz, Benjamin; Kühl, Markus; Müller-Glaser, Klaus D.; Wiesbeck, Werner

    2005-10-01

    TerraSAR-X is a new earth observing satellite which will be launched in spring 2006. It carries a high resolution X-band SAR sensor. For high image data quality, accurate ground calibration targets are necessary. This paper describes a novel system concept for an active and highly integrated, digitally controlled SAR system calibrator. A total of 16 active transponder and receiver systems and 17 receiver only systems will be fabricated for a calibration campaign. The calibration units serve for absolute radiometric calibration of the SAR image data. Additionally, they are equipped with an extra receiver path for two dimensional satellite antenna pattern recognition. The calibrator is controlled by a dedicated digital Electronic Control Unit (ECU). The different voltages needed by the calibrator and the ECU are provided by the third main unit called Power Management Unit (PMU).

  7. Low-reflection beam refractions by ultrathin Huygens metasurface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jia, Sheng Li; State Key Laboratory of Millimeter Waves, School of Information Science and Engineering, Southeast University, Nanjing 210096; Synergetic Innovation Center of Wireless Communication Technology, Southeast University, Nanjing 210096

    2015-06-15

    We propose a Huygens source unit cell to develop an ultrathin low-reflection metasurface, which could provide extreme controls of phases of the transmitted waves. Both electric and magnetic currents are supported by the proposed unit cell, thus leading to highly efficient and full controls of phases. The coupling between electric and magnetic responses is negligible, which will significantly reduce the difficulty of design. Since the unit cell of metasurface is printed on two bonded boards, the fabrication process is simplified and the thickness of metasurface is reduced. Based on the proposed unit cell, a beam-refracting metasurface with low-reflection is designedmore » and manufactured. Both near-field and far-field characteristics of the beam-refracting metasurface are investigated by simulations and measurements, which indicate that the proposed Huygens metasurface performs well in controlling electromagnetic waves.« less

  8. A Study on Aircraft Engine Control Systems for Integrated Flight and Propulsion Control

    NASA Astrophysics Data System (ADS)

    Yamane, Hideaki; Matsunaga, Yasushi; Kusakawa, Takeshi

    A flyable FADEC system engineering model incorporating Integrated Flight and Propulsion Control (IFPC) concept is developed for a highly maneuverable aircraft and a fighter-class engine. An overview of the FADEC system and functional assignments for its components such as the Engine Control Unit (ECU) and the Integrated Control Unit (ICU) are described. Overall system reliability analysis, convex analysis and multivariable controller design for the engine, fault detection/redundancy management, and response characteristics of a fuel system are addressed. The engine control performance of the FADEC is demonstrated by hardware-in-the-loop simulation for fast acceleration and thrust transient characteristics.

  9. Water Ingestion into Axial Flow Compressors. Part III. Experimental Results and Discussion

    DTIC Science & Technology

    1981-10-01

    total pressure, static pressure, and temperature at both compressor inlet and outlet. A United Sensor model PDC-12-G-l0-KL pitot-static pressure probe...Test Compressor inlet and outlet temperatures during water injection tests: United Sensor and Control Corp. type TK-8-CiA-36’-F Aspirate...ured utilizing standard aspirated thermocouples, namely an United Sensor and Control Corp. type TK-8-C/A-36-F. The Test Compressor out- let

  10. C2 of C3: Command and Control of Command, Control, Communication Systems.

    DTIC Science & Technology

    1988-04-22

    capabilities the Army has not yet realized the full benefit of the new technology--largely because of deficiencies in the operational management of these newly...managers frequently constructed CEOI’s by drawing available frequencies or letter/number combinations (for unit callsigns) from a Bingo creel--which was...rapidly occurring changes, with subordinate units. At last, units were beginning to see the benefits of operating from a commonly shared data base. Up to

  11. LANDSAT-D flight segment operations manual, volume 1

    NASA Technical Reports Server (NTRS)

    Varhola, J.

    1982-01-01

    Hardware, systems, and subsystems for the multimission modular spacecraft used for LANDSAT 4 are described and depicted in block diagrams and schematics. Components discussed include the modular attitude control system; the communication and data handling subsystem; the narrowband tape recorder; the on-board computer; the propulsion module subsystem; the signal conditioning and control unit; the modular power subsystem; the solar array drive and power transmission assembly; the power distribution unit; the digital processing unit; and the wideband communication subsystem.

  12. Microgravity induced changes in the control of motor units

    NASA Astrophysics Data System (ADS)

    de Luca, C.; Roy, S.

    The goal of this project is to understand the effects of microgravity on the control of muscles. It is motivated by the notion that in order to adequately address microgravity-induced deterioration in the force generating capacity of muscles, one needs to understand the changes in the control aspects in addition to histochemical and morphological changes. The investigations into muscle control need to include the regulation of the firing activity of motor units that make up a muscle and the coordination of different muscles responsible for the control of a joint. In order to understand the effects of microgravity on these two aspects of muscle control, we will test astronauts before and after spaceflight. The investigations of the control of motor units will involve intramuscular EMG techniques developed in our laboratory. We will use a quadrifilar electrode to detect simultaneously three differential channels of EMG activity. These data will be decomposed accurately using a sophisticated set of algorithms constructed with artificial intelligence knowledge- based techniques. Particular attention will be paid to the firing rate and recruitment behavior of motor units and we will study the degree of cross-correlation of the firing rates. This approach will enable us to study the firing behavior of several (approx. 10) concurrently active motor units. This analysis will enable us to detect modifications in the control of motor units. We will perform these investigations in a hand muscle, which continues being used in prehensile tasks in space, and a leg muscle whose antigravity role is not needed in space. The comparison of the effects of weightlessness on these muscles will determine if continued use of muscles in space deters the possible deleterious effects of microgravity on the control of motor units, in addition to slowing down atrophy. We are particularly interested in comparing the results of this study to similar data already obtained from elderly subjects, because the deleterious effects of migrogravity on muscles is in many ways similar to that of aging. Additionally, we will employ surface EMG techniques to evaluate the effects of microgravity on the coordination of muscles controlling a joint. We will study if the relative contributions from the muscles around the knee joint are redistributed after exposure to microgravity. The insight to be gained from this study will be important in developing countermeasures for maintaining the force generating capacity of muscles in microgravity and rehabilitation programs for aiding in recovery upon return to earth.

  13. Smart house-based optimal operation of thermal unit commitment for a smart grid considering transmission constraints

    NASA Astrophysics Data System (ADS)

    Howlader, Harun Or Rashid; Matayoshi, Hidehito; Noorzad, Ahmad Samim; Muarapaz, Cirio Celestino; Senjyu, Tomonobu

    2018-05-01

    This paper presents a smart house-based power system for thermal unit commitment programme. The proposed power system consists of smart houses, renewable energy plants and conventional thermal units. The transmission constraints are considered for the proposed system. The generated power of the large capacity renewable energy plant leads to the violated transmission constraints in the thermal unit commitment programme, therefore, the transmission constraint should be considered. This paper focuses on the optimal operation of the thermal units incorporated with controllable loads such as Electrical Vehicle and Heat Pump water heater of the smart houses. The proposed method is compared with the power flow in thermal units operation without controllable loads and the optimal operation without the transmission constraints. Simulation results show the validation of the proposed method.

  14. System for fracturing an underground geologic formation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, Jonathan L.; Tappan, Bryce C.; Seitz, Gerald J.

    2017-03-14

    An explosive system for fracturing an underground geologic formation adjacent to a wellbore can comprise a plurality of explosive units comprising an explosive material contained within the casing, and detonation control modules electrically coupled to the plurality of explosive units and configured to cause a power pulse to be transmitted to at least one detonator of at least one of the plurality of explosive units for detonation of the explosive material. The explosive units are configured to be positioned within a wellbore in spaced apart positions relative to one another along a string with the detonation control modules positioned adjacentmore » to the plurality of explosive units in the wellbore, such that the axial positions of the explosive units relative to the wellbore are at least partially based on geologic properties of the geologic formation adjacent the wellbore.« less

  15. Sampling and Analysis for Non-Occupational Pesticide Exposure Assessments

    EPA Science Inventory

    Pesticides are used extensively in the United States to control a variety of pests. Commercial agriculture and non-agricultural industries account for about 80% of the total pesticide use in the United States, while the remaining 20% is used for pest control associated with home,...

  16. 42 CFR 1007.5 - Basic requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Basic requirement. 1007.5 Section 1007.5 Public... STATE MEDICAID FRAUD CONTROL UNITS § 1007.5 Basic requirement. A State Medicaid fraud control unit must... requirements of §§ 1007.7 through 1007.13 of this part. ...

  17. 40 CFR 63.2250 - What are the general requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... periods of process unit or control device startup, shutdown, and malfunction; prior to process unit initial startup; and during the routine control device maintenance exemption specified in § 63.2251. The... are not operating, or during periods of startup, shutdown, and malfunction. Startup and shutdown...

  18. 40 CFR 63.2250 - What are the general requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... periods of process unit or control device startup, shutdown, and malfunction; prior to process unit initial startup; and during the routine control device maintenance exemption specified in § 63.2251. The... are not operating, or during periods of startup, shutdown, and malfunction. Startup and shutdown...

  19. Effect of US health policies on health care access for Marshallese migrants.

    PubMed

    McElfish, Pearl Anna; Hallgren, Emily; Yamada, Seiji

    2015-04-01

    The Republic of the Marshall Islands is a sovereign nation previously under the administrative control of the United States. Since 1986, the Compacts of Free Association (COFA) between the Republic of the Marshall Islands and the United States allows Marshall Islands citizens to freely enter, lawfully reside, and work in the United States, and provides the United States exclusive military control of the region. When the COFA was signed, COFA migrants were eligible for Medicaid and other safety net programs. However, these migrants were excluded from benefits as a consequence of the Personal Responsibility and Work Opportunity Reconciliation Act. Currently, COFA migrants have limited access to health care benefits in the United States, which perpetuates health inequalities.

  20. Effect of US Health Policies on Health Care Access for Marshallese Migrants

    PubMed Central

    Hallgren, Emily; Yamada, Seiji

    2015-01-01

    The Republic of the Marshall Islands is a sovereign nation previously under the administrative control of the United States. Since 1986, the Compacts of Free Association (COFA) between the Republic of the Marshall Islands and the United States allows Marshall Islands citizens to freely enter, lawfully reside, and work in the United States, and provides the United States exclusive military control of the region. When the COFA was signed, COFA migrants were eligible for Medicaid and other safety net programs. However, these migrants were excluded from benefits as a consequence of the Personal Responsibility and Work Opportunity Reconciliation Act. Currently, COFA migrants have limited access to health care benefits in the United States, which perpetuates health inequalities. PMID:25713965

  1. Dynamic of small photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Mehrmann, A.; Kleinkauf, W.; Pigorsch, W.; Steeb, H.

    The results of 1.5 yr of field-testing of two photovoltaic (PV) power plants, one equipped with an electrolyzer and H2 storage, are reported. Both systems were interconnected with the grid and featured the PV module, a power conditioning unit, ac and dc load connections, and control units. The rated power of both units was 100 Wp. The system with electrolysis was governed by control laws which maximized the electrolyzer current. The tests underscored the preference for a power conditioning unit, rather than direct output to load connections. A 1 kWp system was developed in a follow-up program and will be tested in concert with electrolysis and interconnection with several grid customers. The program is geared to eventual development of larger units for utility-size applications.

  2. 45 CFR 5b.9 - Disclosure of records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... individual, organizational unit or class of individuals or organizational units to whom the record may be... individual's records to unspecified individuals or organizational units will not be honored. The subject... or to an instrumentality of any governmental jurisdiction within or under the control of the United...

  3. Final Environmental Impact Statement for Development of Facilities to Support Basing US Pacific Fleet F/A-18E/F Aircraft on the West Coast of the United States, Volume 1.

    DTIC Science & Technology

    1998-05-01

    ROG reactive organic compound RONA Record of Non -applicability RTV rational threshold value RWQCB Regional Water Quality Control Board SARA...over water. The ranges are either scheduled via a designated military or civilian controlling agency (for restricted or warning areas) or are used...operations areas (MOAs), and air traffic control authorized airspace (ATCAA). Airspace designations throughout the United States are controlled by the Federal

  4. 31 CFR 592.312 - United States person; U.S. person.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false United States person; U.S. person. 592.312 Section 592.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS General...

  5. 31 CFR 592.312 - United States person; U.S. person.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false United States person; U.S. person. 592.312 Section 592.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS General...

  6. 31 CFR 592.305 - Importation into the United States.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Importation into the United States. 592.305 Section 592.305 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS...

  7. 31 CFR 592.312 - United States person; U.S. person.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false United States person; U.S. person. 592.312 Section 592.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS General...

  8. 31 CFR 592.305 - Importation into the United States.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Importation into the United States. 592.305 Section 592.305 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS...

  9. 31 CFR 592.305 - Importation into the United States.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Importation into the United States. 592.305 Section 592.305 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY ROUGH DIAMONDS CONTROL REGULATIONS...

  10. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization and...

  11. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization and...

  12. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization and...

  13. 26 CFR 1.956-3T - Certain trade or service receivables acquired from United States persons (temporary).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... investment in United States property by the seller's controlled foreign corporation, unless it can be... SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Controlled Foreign... foreign corporation has acquired a trade or service receivable. (2) Indirect acquisitions—(i) Acquisition...

  14. 77 FR 69556 - Airworthiness Directives; Eurocopter Deutschland Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-20

    ..., 2011. (h) Subject Joint Aircraft Service Component (JASC) Code: 2436: DC Generator Control Unit. Issued... Deutschland GmbH (ECD) Model MBB-BK117 C-2 helicopters with certain Generator Control Units (GCU) installed... Ground Floor, Room W12- 140, 1200 New Jersey Avenue SE., Washington, DC 20590. FOR FURTHER INFORMATION...

  15. 42 CFR 455.21 - Cooperation with State Medicaid fraud control units.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Cooperation with State Medicaid fraud control units. 455.21 Section 455.21 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS PROGRAM INTEGRITY: MEDICAID Medicaid Agency Fraud...

  16. 15 CFR 760.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... project financing by a United States bank located in the United States to a controlled foreign subsidiary... controlled foreign subsidiary's construction project in a third country are services passed through to the... boycotting country Y for computers. A places an order with U.S. company B for some of the components; with U...

  17. 15 CFR 760.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... project financing by a United States bank located in the United States to a controlled foreign subsidiary... controlled foreign subsidiary's construction project in a third country are services passed through to the... boycotting country Y for computers. A places an order with U.S. company B for some of the components; with U...

  18. Electrical Procedures and Environmental Control Systems. Building Maintenance. Module IV. Instructor's Guide.

    ERIC Educational Resources Information Center

    Sloan, Garry

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for two units on electrical procedures and environmental control systems. Unit 1, on electrical procedures, includes the following lessons: electrical safety; troubleshooting and…

  19. 31 CFR 545.404 - Transshipment or transit through the United States prohibited.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (AFGHANISTAN) SANCTIONS REGULATIONS Interpretations § 545.404 Transshipment or transit through the United... intended or destined for the Taliban or the territory of Afghanistan controlled by the Taliban. (b) The... Afghanistan controlled by the Taliban which are intended or destined for third countries. (c) Goods, software...

  20. Impact of Shutting Down En Route Primary Radars within CONUS Interior

    DTIC Science & Technology

    1993-06-01

    Remote Control Interface Unit ( RCIU ) RMS software for the primary radar will be deleted. Any dependency of the secondary radar on the primary radar data...Generators RCIU Remote Control and Interface Unit RMM Remote Monitoring and Maintenance RMMS Remote Maintenance Monitoring System RMS Remote Maintenance

  1. Arms Control and National Security.

    ERIC Educational Resources Information Center

    Graham, Daniel O.

    1985-01-01

    From the Soviet perspective arms control agreements merely hold the United States in check while the Soviets, who don't feel bound by such agreements, obtain military advantages. The United States must move quickly to redress the strategic military balance that now favors the Soviets. We must emphasize areas like space. (RM)

  2. 76 FR 14637 - State Medicaid Fraud Control Units; Data Mining

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ...] State Medicaid Fraud Control Units; Data Mining AGENCY: Office of Inspector General (OIG), HHS. ACTION... and analyzing State Medicaid claims data, known as data mining. To support and modernize MFCU efforts... (FFP) in the costs of defined data mining activities under specified conditions. In addition, we...

  3. 15 CFR 760.1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... project financing by a United States bank located in the United States to a controlled foreign subsidiary... controlled foreign subsidiary's construction project in a third country are services passed through to the... boycotting country Y for computers. A places an order with U.S. company B for some of the components; with U...

  4. 15 CFR 760.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... project financing by a United States bank located in the United States to a controlled foreign subsidiary... controlled foreign subsidiary's construction project in a third country are services passed through to the... boycotting country Y for computers. A places an order with U.S. company B for some of the components; with U...

  5. 15 CFR 760.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... project financing by a United States bank located in the United States to a controlled foreign subsidiary... controlled foreign subsidiary's construction project in a third country are services passed through to the... boycotting country Y for computers. A places an order with U.S. company B for some of the components; with U...

  6. The Design and Analysis of Pediatric Vaccine Formularies: Theory and Practice

    DTIC Science & Technology

    2006-06-22

    Schedule—United States. Morbidity and Mortality Weekly Report; 54(52):Q1-Q4. Centers for Disease Control and Prevention. 2005. Recommended...Childhood and Adolescent Immunization Schedule—United States. Morbidity and Mortality Weekly Report; 53:Q1-Q3. Centers for Disease Control and Prevention... Mortality Weekly Report; 52(RR-1);34-36. Centers for Disease Control and Prevention. 2002. General Recommendations on Immunization. Morbidity and

  7. Roadside-based communication system and method

    NASA Technical Reports Server (NTRS)

    Bachelder, Aaron D. (Inventor)

    2007-01-01

    A roadside-based communication system providing backup communication between emergency mobile units and emergency command centers. In the event of failure of a primary communication, the mobile units transmit wireless messages to nearby roadside controllers that may take the form of intersection controllers. The intersection controllers receive the wireless messages, convert the messages into standard digital streams, and transmit the digital streams along a citywide network to a destination intersection or command center.

  8. History of Special Operations Forces in Malaysia

    DTIC Science & Technology

    2013-06-01

    Transformation,” an article for the 11th International Command and Control Research and Technology Symposium, 2006, http://www.dodccrp.org/events...the 91 Grup Operasi Perisikan (GOP). This unit is a special combat unit in the Army Intelligence Corps, placed under the operational control of the...and Control Research and Technology Symposium 2006, http://www.dodccrp.org/events/11th_ICCRTS/html/papers/061.pdf (accessed February 29, 2012

  9. Hand-Held Self-Maneuvering Unit to be used during EVA on Gemini 4

    NASA Image and Video Library

    1965-06-02

    Hand-Held Self-Maneuvering Unit to be used during extravehicular activity (EVA) on Gemini 4 flight. It is an integral unit that contains its own high pressure metering valves and nozzles required to produce controlled thrust. A camera is mounted on the front of the unit.

  10. 40 CFR 63.1275 - Glycol dehydration unit process vent standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...

  11. 40 CFR 63.1275 - Glycol dehydration unit process vent standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...

  12. 28 CFR 0.135 - Functions common to heads of organizational units.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... organizational unit authority and responsibility for the reallotment of such funds and control of obligations and... organizational units. 0.135 Section 0.135 Judicial Administration DEPARTMENT OF JUSTICE ORGANIZATION OF THE... Disqualification to Act § 0.135 Functions common to heads of organizational units. Subject to the general...

  13. The Control Unit of KM3NeT data acquisition

    NASA Astrophysics Data System (ADS)

    Bozza, Cristiano

    2016-04-01

    The KM3NeT Collaboration is building a new generation of neutrino telescopes in the Mediterranean Sea. With the telescopes, scientists will search for cosmic neutrinos to study highly energetic objects in the Universe, while one neutrino detector will be dedicated to measure the properties of the high-energy neutrino particles themselves. Control of the KM3NeT data acquisition processes is handled by the KM3NeT Control Unit, which has been designed to maximise the detector live time. The Control Unit features software programs with different roles, following the philosophy of having no single point of failure. While all programs are interconnected, each one can also work alone for most of the time in case other services are unavailable. All services run on the Common Language Runtime, which ensures portability, flexibility and automatic memory management. Each service has an embedded Web server, providing a user interface as well as programmatic access to data and functions. Data to and from detector components for monitoring and management purposes are transmitted using a custom designed protocol. The Control Unit is interfaced to one or more Message Dispatchers to control the data acquisition chain. A Data Base Interface provides fast and fault-tolerant connection to a remote Data Base.

  14. Multiple-Agent Air/Ground Autonomous Exploration Systems

    NASA Technical Reports Server (NTRS)

    Fink, Wolfgang; Chao, Tien-Hsin; Tarbell, Mark; Dohm, James M.

    2007-01-01

    Autonomous systems of multiple-agent air/ground robotic units for exploration of the surfaces of remote planets are undergoing development. Modified versions of these systems could be used on Earth to perform tasks in environments dangerous or inaccessible to humans: examples of tasks could include scientific exploration of remote regions of Antarctica, removal of land mines, cleanup of hazardous chemicals, and military reconnaissance. A basic system according to this concept (see figure) would include a unit, suspended by a balloon or a blimp, that would be in radio communication with multiple robotic ground vehicles (rovers) equipped with video cameras and possibly other sensors for scientific exploration. The airborne unit would be free-floating, controlled by thrusters, or tethered either to one of the rovers or to a stationary object in or on the ground. Each rover would contain a semi-autonomous control system for maneuvering and would function under the supervision of a control system in the airborne unit. The rover maneuvering control system would utilize imagery from the onboard camera to navigate around obstacles. Avoidance of obstacles would also be aided by readout from an onboard (e.g., ultrasonic) sensor. Together, the rover and airborne control systems would constitute an overarching closed-loop control system to coordinate scientific exploration by the rovers.

  15. Motor control differs for increasing and releasing force

    PubMed Central

    Park, Seoung Hoon; Kwon, MinHyuk; Solis, Danielle; Lodha, Neha

    2016-01-01

    Control of the motor output depends on our ability to precisely increase and release force. However, the influence of aging on force increase and release remains unknown. The purpose of this study, therefore, was to determine whether force control differs while increasing and releasing force in young and older adults. Sixteen young adults (22.5 ± 4 yr, 8 females) and 16 older adults (75.7 ± 6.4 yr, 8 females) increased and released force at a constant rate (10% maximum voluntary contraction force/s) during an ankle dorsiflexion isometric task. We recorded the force output and multiple motor unit activity from the tibialis anterior (TA) muscle and quantified the following outcomes: 1) variability of force using the SD of force; 2) mean discharge rate and variability of discharge rate of multiple motor units; and 3) power spectrum of the multiple motor units from 0–4, 4–10, 10–35, and 35–60 Hz. Participants exhibited greater force variability while releasing force, independent of age (P < 0.001). Increased force variability during force release was associated with decreased modulation of multiple motor units from 35 to 60 Hz (R2 = 0.38). Modulation of multiple motor units from 35 to 60 Hz was further correlated to the change in mean discharge rate of multiple motor units (r = 0.66) and modulation from 0 to 4 Hz (r = −0.64). In conclusion, these findings suggest that force control is altered while releasing due to an altered modulation of the motor units. PMID:26961104

  16. Improving teamwork: impact of structured interdisciplinary rounds on a hospitalist unit.

    PubMed

    O'Leary, Kevin J; Haviley, Corinne; Slade, Maureen E; Shah, Hiren M; Lee, Jungwha; Williams, Mark V

    2011-02-01

    Effective collaboration and teamwork is essential in providing safe and effective care. Research reveals deficiencies in teamwork on medical units involving hospitalists. The aim of this study was to assess the impact of an intervention, Structured Inter-Disciplinary Rounds (SIDR), on nurses' ratings of collaboration and teamwork. The study was a controlled trial involving an intervention and control hospitalist unit. The intervention, SIDR, combined a structured format for communication with a forum for regular interdisciplinary meetings. We asked nurses to rate the quality of communication and collaboration with hospitalists using a 5-point ordinal scale. We also assessed teamwork and safety climate using a validated instrument. Multivariable regression analyses were used to assess the impact on length of stay (LOS) and cost using both a concurrent and historic control. A total of 49 of 58 (84%) nurses completed surveys. A larger percentage of nurses rated the quality of communication and collaboration with hospitalists as high or very high on the intervention unit compared to the control unit (80% vs. 54%; P = 0.05). Nurses also rated the teamwork and safety climate significantly higher on the intervention unit (P = 0.008 and P = 0.03 for teamwork and safety climate, respectively). Multivariable analyses demonstrated no difference in the adjusted LOS and an inconsistent effect on cost. SIDR had a positive effect on nurses' ratings of collaboration and teamwork on a hospitalist unit, yet no impact on LOS and cost. Further study is required to assess the impact of SIDR on patient safety measures. Copyright © 2010 Society of Hospital Medicine.

  17. Differences in liquor prices between control state-operated and license-state retail outlets in the United States.

    PubMed

    Siegel, Michael; DeJong, William; Albers, Alison B; Naimi, Timothy S; Jernigan, David H

    2013-02-01

    This study aims to compare the average price of liquor in the United States between retail alcohol outlets in states that have a monopoly ('control' states) with those that do not ('licence' states). A cross-sectional study of brand-specific alcohol prices in the United States. We determined the average prices in February 2012 of 74 brands of liquor among the 13 control states that maintain a monopoly on liquor sales at the retail level and among a sample of 50 license-state liquor stores, using their online-available prices. We calculated average prices for 74 brands of liquor by control versus license state. We used a random-effects regression model to estimate differences between control and license state prices-overall and by alcoholic beverage type. We also compared prices between the 13 control states. The overall mean price for the 74 brands was $27.79 in the license states [95% confidence interval (CI): $25.26-30.32] and $29.82 in the control states (95% CI: $26.98-32.66). Based on the random-effects linear regression model, the average liquor price was approximately $2 lower (6.9% lower) in license states. In the United States monopoly of alcohol retail outlets appears to be associated with slightly higher liquor prices. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  18. Characterization of the Advanced Stirling Radioisotope Generator Engineering Unit 2

    NASA Technical Reports Server (NTRS)

    Lewandowski, Edward J.; Oriti, Salvatore M.; Schifer, Niholas A.

    2016-01-01

    Significant progress was made developing the Advanced Stirling Radioisotope Generator (ASRG) 140-W radioisotope power system. While the ASRG flight development project has ended, the hardware that was designed and built under the project is continuing to be tested to support future Stirling-based power system development. NASA Glenn Research Center recently completed the assembly of the ASRG Engineering Unit 2 (EU2). The ASRG EU2 consists of the first pair of Sunpower's Advanced Stirling Convertor E3 (ASC-E3) Stirling convertors mounted in an aluminum housing, and Lockheed Martin's Engineering Development Unit (EDU) 4 controller (a fourth-generation controller). The ASC-E3 convertors and Generator Housing Assembly (GHA) closely match the intended ASRG Qualification Unit flight design. A series of tests were conducted to characterize the EU2, its controller, and the convertors in the flight-like GHA. The GHA contained an argon cover gas for these tests. The tests included measurement of convertor, controller, and generator performance and efficiency; quantification of control authority of the controller; disturbance force measurement with varying piston phase and piston amplitude; and measurement of the effect of spacecraft direct current (DC) bus voltage on EU2 performance. The results of these tests are discussed and summarized, providing a basic understanding of EU2 characteristics and the performance and capability of the EDU 4 controller.

  19. Nonlinear predictive control of a boiler-turbine unit: A state-space approach with successive on-line model linearisation and quadratic optimisation.

    PubMed

    Ławryńczuk, Maciej

    2017-03-01

    This paper details development of a Model Predictive Control (MPC) algorithm for a boiler-turbine unit, which is a nonlinear multiple-input multiple-output process. The control objective is to follow set-point changes imposed on two state (output) variables and to satisfy constraints imposed on three inputs and one output. In order to obtain a computationally efficient control scheme, the state-space model is successively linearised on-line for the current operating point and used for prediction. In consequence, the future control policy is easily calculated from a quadratic optimisation problem. For state estimation the extended Kalman filter is used. It is demonstrated that the MPC strategy based on constant linear models does not work satisfactorily for the boiler-turbine unit whereas the discussed algorithm with on-line successive model linearisation gives practically the same trajectories as the truly nonlinear MPC controller with nonlinear optimisation repeated at each sampling instant. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Variations in incubator temperature and humidity management: a survey of current practice.

    PubMed

    Deguines, C; Décima, P; Pelletier, A; Dégrugilliers, L; Ghyselen, L; Tourneux, P

    2012-03-01

    To describe and assess routine procedures and practices for incubator temperature and humidity management in France in 2009. A questionnaire was sent to all the 186 neonatal care units in France. The questionnaire return rate was 86%. Seventy-five per cent of the units preferred skin servo-control to air temperature control in routine practice. Air temperature control was mainly used for infants with a gestational age of more than 28 weeks and aged over 7 days of life. In general, thermal management decisions did not depend on the infant's age but were based on a protocol applied specifically by each unit. All units humidified the incubator air, but there was a large difference between the lowest and highest reported humidity values (45% and 100% assumed to be a maximal value, respectively). More than 65% of the units used a fixed humidity value, rather than a variable, protocol-derived value. We observed large variations in incubator temperature and humidity management approaches from one neonatal care unit to another. There is a need for more evidence to better inform practice. A task force should be formed to guide clinical practice. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.

Top