Sample records for control urine samples

  1. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: application for transrenal Mycobacterium tuberculosis DNA detection

    PubMed Central

    Bordelon, Hali; Ricks, Keersten M.; Pask, Megan E.; Russ, Patricia K.; Solinas, Francesca; Baglia, Mark L.; Short, Philip A.; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W.; Haselton, Frederick R.; Pettit, April C.

    2017-01-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1 milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5 mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found a increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. PMID:28285168

  2. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: Application for transrenal Mycobacterium tuberculosis DNA detection.

    PubMed

    Bordelon, Hali; Ricks, Keersten M; Pask, Megan E; Russ, Patricia K; Solinas, Francesca; Baglia, Mark L; Short, Philip A; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W; Haselton, Frederick R; Pettit, April C

    2017-05-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found an increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    PubMed

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  4. The resident microflora of voided midstream urine of healthy controls: standard versus expanded urine culture protocols.

    PubMed

    Coorevits, L; Heytens, S; Boelens, J; Claeys, G

    2017-04-01

    The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3  colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4  CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.

  5. Measurement of Phenolic Environmental Estrogens in Women with Uterine Leiomyoma

    PubMed Central

    Shen, Yang; Xu, Qian; Ren, Mulan; Feng, Xu; Cai, Yunlang; Gao, Yongxing

    2013-01-01

    Objectives To investigate the effect of phenolic environmental estrogens on uterine leiomyoma from the perspective of clinical epidemiology. Methods Urine and blood samples were collected from Han women with uterine leiomyoma and women without uterine leiomyoma, living in Nanjing, China, between September 2011 and February 2013. A total of 156 urine samples and 214 blood samples were collected from the uterine leiomyoma group and 106 urine samples and 126 blood plasma samples from the control group. Bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP) concentrations were determined by solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Results Phenolic environmental estrogens in the uterine leiomyoma and control groups were compared based on: gravida>3 and gravida ≤ 3. In participants with gravida>3, urine OP concentration was significantly (P<0.05) higher in the uterine leiomyoma group than in the control group. In participants with gravida ≤ 3, urine NP concentration was significantly (P<0.05) higher in the uterine leiomyoma group compared to controls. Despite obstetric history, urine BPA mean exposure concentration was significantly (P<0.05) different between uterine leiomyoma group and control group. The urine BPA concentration was not significantly (P>0.05) different between gravida>3 and gravida ≤ 3 patients. There was no significant (P>0.05) difference in plasma concentrations of BPA, OP and NP between the leiomyoma group and control group. Mean exposure concentration and range of distribution of BPA, OP and NP plasma concentration differed between the uterine leiomyoma and control group. Conclusion Exposure level of phenolic environmental estrogens in human was related with leiomyoma tumorigenesis. PMID:24255718

  6. DNA typing for personal identification of urine after long-term preservation for testing in doping control.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto

    2017-08-01

    When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Doping control study of AICAR in post-race urine and plasma samples from horses.

    PubMed

    Wong, Jenny K Y; Kwok, Wai Him; Chan, George H M; Choi, Timmy L S; Ho, Emmie N M; Jaubert, Murielle; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Cawley, Adam; Ming Williams, H; Keledjian, John; Brooks, Lydia; Chambers, Adam; Lin, Yuanyuan; Wan, Terence S M

    2017-09-01

    Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  9. [An investigation of lanthanum and other metals levels in blood, urine and hair among residents in the rare earth mining area of a city in China].

    PubMed

    Bao, T M; Tian, Y; Wang, L X; Wu, T; Lu, L N; Ma, H Y; Wang, L

    2018-02-20

    Objective: To investigate the levels of lanthanum, cerium, praseodymium, and neodymium in the blood, urine, and hair samples from residents in the rare earth mining area of a city in China, and to provide a scientific basis for the control of rare earth pollution and the protection of population health. Methods: A total of 147 residents who had lived in the rare earth mining area of a city for a long time were selected as the exposure group, and 108 residents in Guyang County of this city who lived 91 km away from the rare earth mining area were selected as the control group. Blood, urine, and hair samples were collected from the residents in both groups. Inductively coupled plasma mass spectrometry was used to determine the content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair samples. Results: In the exposure group, the median levels of lanthanum, cerium, praseodymium, and neodymium were 0.854, 1.724, 0.132, and 0.839 μg/L, respectively, in blood samples, 0.420, 0.920, 0.055, and 0.337 μg/L, respectively, in urine samples, and 0.052, 0.106, 0.012, and 0.045 μg/g, respectively, in hair samples. The exposure group had significantly higher levels of the four rare earth elements in blood, urine, and hair samples than the control group ( P <0.01) . Conclusion: The residents in the rare earth mining area of this city have higher content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair than those in the non-mining area; the content of cerium is highest, followed by lanthanum, neodymium, and praseodymium.

  10. Measurements of C-reactive protein (CRP) and nerve-growth-factor (NGF) concentrations in serum and urine samples of dogs with neurologic disorders.

    PubMed

    Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea

    2016-01-08

    The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.

  11. Gene expression signature in urine for diagnosing and assessing aggressiveness of bladder urothelial carcinoma.

    PubMed

    Mengual, Lourdes; Burset, Moisès; Ribal, María José; Ars, Elisabet; Marín-Aguilera, Mercedes; Fernández, Manuel; Ingelmo-Torres, Mercedes; Villavicencio, Humberto; Alcaraz, Antonio

    2010-05-01

    To develop an accurate and noninvasive method for bladder cancer diagnosis and prediction of disease aggressiveness based on the gene expression patterns of urine samples. Gene expression patterns of 341 urine samples from bladder urothelial cell carcinoma (UCC) patients and 235 controls were analyzed via TaqMan Arrays. In a first phase of the study, three consecutive gene selection steps were done to identify a gene set expression signature to detect and stratify UCC in urine. Subsequently, those genes more informative for UCC diagnosis and prediction of tumor aggressiveness were combined to obtain a classification system of bladder cancer samples. In a second phase, the obtained gene set signature was evaluated in a routine clinical scenario analyzing only voided urine samples. We have identified a 12+2 gene expression signature for UCC diagnosis and prediction of tumor aggressiveness on urine samples. Overall, this gene set panel had 98% sensitivity (SN) and 99% specificity (SP) in discriminating between UCC and control samples and 79% SN and 92% SP in predicting tumor aggressiveness. The translation of the model to the clinically applicable format corroborates that the 12+2 gene set panel described maintains a high accuracy for UCC diagnosis (SN = 89% and SP = 95%) and tumor aggressiveness prediction (SN = 79% and SP = 91%) in voided urine samples. The 12+2 gene expression signature described in urine is able to identify patients suffering from UCC and predict tumor aggressiveness. We show that a panel of molecular markers may improve the schedule for diagnosis and follow-up in UCC patients. Copyright 2010 AACR.

  12. SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.

    PubMed

    Liu, Zhenjiang; Yuan, Zhengwei; Zhao, Qun

    2014-01-01

    Neural tube defects (NTDs) are common birth defects, whose specific biomarkers are needed. The purpose of this pilot study is to determine whether protein profiling in NTD-mothers differ from normal controls using SELDI-TOF-MS. ProteinChip Biomarker System was used to evaluate 82 maternal serum samples, 78 urine samples and 76 amniotic fluid samples. The validity of classification tree was then challenged with a blind test set including another 20 NTD-mothers and 18 controls in serum samples, and another 19 NTD-mothers and 17 controls in urine samples, and another 20 NTD-mothers and 17 controls in amniotic fluid samples. Eight proteins detected in serum samples were up-regulated and four proteins were down-regulated in the NTD group. Four proteins detected in urine samples were up-regulated and one protein was down-regulated in the NTD group. Six proteins detected in amniotic fluid samples were up-regulated and one protein was down-regulated in the NTD group. The classification tree for serum samples separated NTDs from healthy individuals, achieving a sensitivity of 91% and a specificity of 97% in the training set, and achieving a sensitivity of 90% and a specificity of 97% and a positive predictive value of 95% in the test set. The classification tree for urine samples separated NTDs from controls, achieving a sensitivity of 95% and a specificity of 94% in the training set, and achieving a sensitivity of 89% and a specificity of 82% and a positive predictive value of 85% in the test set. The classification tree for amniotic fluid samples separated NTDs from controls, achieving a sensitivity of 93% and a specificity of 89% in the training set, and achieving a sensitivity of 90% and a specificity of 88% and a positive predictive value of 90% in the test set. These suggest that SELDI-TOF-MS is an additional method for NTDs pregnancies detection.

  13. ECLSS Sustaining Compatibility Testing on Urine Processor Assembly Nonmetallic Materials for Reformulation of Pretreated Urine Solution

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2015-01-01

    On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.

  14. Genital region cleansing wipes: Effects on urine culture contamination.

    PubMed

    Selek, Mehmet Burak; Bektöre, Bayhan; Sezer, Ogün; Kula Atik, Tuğba; Baylan, Orhan; Özyurt, Mustafa

    2017-01-30

    Urine culture is the gold standard test for revealing the microbial agent causing urinary tract infection (UTI). Culture results are affected by sampling techniques; improper sampling leads to contamination of urine and thus contamination of the culture with urogenital flora. We aimed to evaluate the effect of urogenital cleansing, performed with chlorhexidine-containing genital region cleansing wipes (GRCW) on contamination rates. A total of 2,665 patients with UTI-related complaints and with urine culture requests from various outpatient clinics were enrolled in the study. Of the patients, 1,609 in the experimental group used GRCW before sampling, while 1,046 in the control group did not use any wipes. The contamination rate in the experimental group patients was 7.7%, while it was 15.8% in the control group. Contamination rates were significantly higher in the control group than in the experimental group for both women and men. Contamination rates for children and adults were also significantly lower in the experimental group than in the control group. Our study, conducted in a large population, showed that the use of chlorhexidine-containing cleansing wipes significantly reduced urine culture contamination rates in both genders, in both child and adult age groups. Using GRCW, collection of urine after urogenital area cleansing will decrease the contamination problem.

  15. Urine analysis concerning xenon for doping control purposes.

    PubMed

    Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm

    2015-01-15

    On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    PubMed

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  17. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  18. The simultaneous detection of trivalent & hexavalent chromium in exhaled breath condensate: A feasibility study comparing workers and controls.

    PubMed

    Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A

    2017-04-01

    The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.

  19. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  20. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    PubMed

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Midstream clean-catch urine collection in newborns: a randomized controlled study.

    PubMed

    Altuntas, Nilgun; Tayfur, Asli Celebi; Kocak, Mesut; Razi, Hasan Cem; Akkurt, Serpil

    2015-05-01

    We aimed to evaluate a recently defined technique based on bladder stimulation and paravertebral lumbar massage maneuvers in collecting a midstream clean-catch urine sample in newborns. A total of 127 term newborns were randomly assigned either to the experimental group or the control group. Twenty-five minutes after feeding, the genital and perineal areas of the babies were cleaned. The babies were held under the armpits with legs dangling. Bladder stimulation and lumbar paravertebral massage maneuvers were only applied to the babies in the experimental group. Success was defined as collection of a urine sample within 5 min of starting the stimulation maneuvers in the experimental group and of holding under the armpits in the control group. The success rate of urine collection was significantly higher in the experimental group (78%) than in the control group (33%; p < 0.001). The median time (interquartile range) for sample collection was 60 s (64.5 s) in the experimental group and 300 s (95 s) in the control group (p < 0.0001). Contamination rates were similar in both groups (p = 0.770). We suggest that bladder stimulation and lumbar paravertebral massage is a safe, quick, and effective way of collecting midstream clean-catch urine in newborns.

  2. Diagnosis and effects of urine contamination in cooled-extended stallion semen.

    PubMed

    Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K

    2016-04-15

    Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Detection of Circulating Paracoccidioides brasiliensis Antigen in Urine of Paracoccidioidomycosis Patients before and during Treatment

    PubMed Central

    Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares

    1998-01-01

    For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407

  4. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study

    PubMed Central

    Almaani, Salem; Hebert, Lee A.; Rovin, Brad H.

    2017-01-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β-2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid–mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. PMID:28104821

  5. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study.

    PubMed

    Almaani, Salem; Hebert, Lee A; Rovin, Brad H; Birmingham, Daniel J

    2017-05-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β -2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid-mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. Copyright © 2017 by the American Society of Nephrology.

  6. Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.

    PubMed

    Shelver, Weilin L; Smith, David J

    2018-06-06

    Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.

  7. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  8. Evaluation of the BinaxNOW® Streptococcus pneumoniae antigen test on fresh, frozen and concentrated urine samples in elderly patients with and without community-acquired pneumonia.

    PubMed

    Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A

    2016-02-01

    We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Detection and genotyping of HPV in urine samples from Chilean women attending primary health care centers.

    PubMed

    Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio

    2018-04-01

    Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.

  10. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    PubMed

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for the stabilization of EtG in urine samples.

  11. Natural calcium isotonic composition of urine as a marker of bone mineral balance

    USGS Publications Warehouse

    Skulan, J.; Bullen, T.; Anbar, A.D.; Puzas, J.E.; Shackelford, L.; LeBlanc, A.; Smith, S.M.

    2007-01-01

    Background: We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Methods: Calcium isotopic compositions are expressed as ??44Ca, or the difference in parts per thousand between the 44Ca/40Ca of a sample and the 44Ca/ 40Ca of a standard reference material. ??44Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Results: Urine ??44Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, Mest). Results were consistent with the model and with biochemical and bone mineral density data. Conclusion: Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool. ?? 2007 American Association for Clinical Chemistry.

  12. Natural calcium isotopic composition of urine as a marker of bone mineral balance.

    PubMed

    Skulan, Joseph; Bullen, Thomas; Anbar, Ariel D; Puzas, J Edward; Shackelford, Linda; LeBlanc, Adrian; Smith, Scott M

    2007-06-01

    We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Calcium isotopic compositions are expressed as delta(44)Ca, or the difference in parts per thousand between the (44)Ca/(40)Ca of a sample and the (44)Ca/(40)Ca of a standard reference material. delta(44)Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Urine delta(44)Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, t-test). Results were consistent with the model and with biochemical and bone mineral density data. Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool.

  13. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.

    PubMed

    Holm, Anne; Aabenhus, Rune

    2016-06-08

    Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.

  14. Measurement of urinary 11-dehydro-thromboxane B2 excretion in dogs with gastric dilatation-volvulus.

    PubMed

    Baltzer, Wendy I; McMichael, Maureen A; Ruaux, Craig G; Noaker, Laura; Steiner, Jörg M; Williams, David A

    2006-01-01

    To measure 11-dehydro-thromboxane B2 (11-dTXB2) in urine of healthy control dogs, dogs undergoing ovariohysterectomy, and dogs with gastric dilatation-volvulus (GDV) and assess the relationship between urinary 11-dTXB2 concentrations in dogs with GDV and postoperative outcomes. Urine samples from 15 nonsurgical control dogs, 12 surgical control dogs, and 32 dogs with GVD. Urine samples were obtained from healthy pet dogs (ie, nonsurgical control dogs), dogs undergoing ovariohysterectomy at anesthetic induction and 1 hour following surgery (ie, surgical control dogs), and dogs with GDV at hospital admission and 1 hour following surgical derotation of the stomach (ie, GDV dogs). Urinary 11-dTXB2 concentrations were determined with an ELISA and normalized to urinary creatinine (Cr) concentrations by calculation of the 11-dTXB2 -to-Cr ratio. Differences in median 11-dTXB2 -to-Cr ratios among dogs and before and after surgery were analyzed. Urinary 11-dTXB2-to-Cr ratios did not differ between nonsurgical control dogs and surgical control dogs before or after surgery. Urinary 11-dTXB2-to-Cr ratios were significantly higher in GDV dogs at the time of hospital admission and 1 hour after surgery, compared with those of nonsurgical control dogs. Postoperative urine samples from GDV dogs had significantly higher 11-dTXB2-to-Cr ratios than postoperative urine samples from surgical control dogs. Median urinary 11-dTXB2-to-Cr ratios increased significantly in GDV dogs that developed postoperative complications. Urinary 11-dTXB2 concentration is increased in GDV dogs at the time of hospital admission and after surgical derotation of the stomach, compared with that of healthy dogs. An increased urinary 11-dTXB2-to-Cr ratio following surgery is associated with an increased incidence of postoperative complications in dogs with GDV.

  15. Evaluation of commercial boric acid containing vials for urine culture: low risk of contamination and cost effectiveness considerations.

    PubMed

    Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam

    2013-01-01

    Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.

  16. [The role of telomerase activity in non-invasive diagnostics of bladder cancer].

    PubMed

    Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A

    2016-08-01

    To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.

  17. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  18. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    PubMed

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.

  19. Prevalence of caffeine use in elite athletes following its removal from the World Anti-Doping Agency list of banned substances.

    PubMed

    Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús

    2011-08-01

    The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.

  20. Hormonal responses of pilots flying high-performance aircraft during seven repetitive flight missions.

    PubMed

    Tarui, H; Nakamura, A

    1991-12-01

    Hormonal responses during seven repetitive flight missions (7RFM) were evaluated on F-4EJ fighter pilots. The following biochemical constituents were measured: 1) cortisol in saliva; 2) 17-OHCS; 3) unbound cortisol; 4) catecholamines in urine; and 5) electrolytes in urine. Samples were collected at about 30 min before the mission, 20 min after each flight, and in a nonflight day for control. The levels of saliva and urine corticosteroids slightly increased during 7RFM when compared with controls. The concentrations of urine catecholamines during 7RFM were significantly higher than those of preflight and control. These data suggest that flight stresses were moderate for the pilots flying 7RFM.

  1. Pure human urine is a good fertiliser for cucumbers.

    PubMed

    Heinonen-Tanski, Helvi; Sjöblom, Annalena; Fabritius, Helena; Karinen, Päivi

    2007-01-01

    Human urine obtained from separating toilets was tested as a fertiliser for cultivation of outdoor cucumber (Cucumis sativus L.) in a Nordic climate. The urine used contained high amounts of nitrogen with some phosphorus and potassium, but numbers of enteric microorganisms were low even though urine had not been preserved before sampling. The cucumber yield after urine fertilisation was similar or slightly better than the yield obtained from control rows fertilised with commercial mineral fertiliser. None of the cucumbers contained any enteric microorganisms (coliforms, enterococci, coliphages and clostridia). In the taste assessment, 11 out of 20 persons could recognise which cucumber of three cucumbers was different but they did not prefer one over the other cucumber samples, since all of them were assessed as equally good.

  2. Practical and quality-control aspects of multi-element analysis with quadrupole ICP-MS with special attention to urine and whole blood.

    PubMed

    De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert

    2004-07-01

    Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.

  3. Prostate cancer antigen 3 gene expression in peripheral blood and urine sediments from prostate cancer and benign prostatic hyperplasia patients versus healthy individuals.

    PubMed

    Moradi Sardareh, Hemen; Goodarzi, Mohammad Taghi; Yadegar-Azari, Reza; Poorolajal, Jalal; Mousavi-Bahar, Seyed Habibollah; Saidijam, Massoud

    2014-11-30

    To determine the expression of prostate cancer antigen 3 (PCA3) gene in peripheral blood and urine sediments from patients with prostate cancer (PCa) and benign prostatic hyperplasia (BPH) and normal subjects. A total number of 48 patients [24 with biopsy proven prostate cancer (PCa) and 24 with benign prostate hyperplasia (BPH)] were studied. Twenty-four healthy individuals were also recruited as control group. After blood and urine sampling, total RNA was extracted and cDNA was synthesized. Expression of PCA3 gene was assessed by quantitative reverse transcription polymerase chain reaction. Comparison of PCA3 gene expression between control and BPH groups indicated no statistically significant differences in both urine and blood samples. Patients with PCa demonstrated an increased PCA3 gene expression rate compared to control and BPH groups (10.64 and 7.17 folds, respectively). The rate of fold increased PCA3 gene expression in urine was 20.90, 20.90, and 20.35 in patients with PCa, BPH and normal subjects, respectively. Evaluation of PCA3 gene expression can be considered as a reliable marker for detection of PCa. Increased level of this marker in urine sediments is more sensitive than blood for distinguishing between cancerous and non-cancerous groups. 

  4. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong

    2014-11-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.

  5. Volatile organic compounds as biomarkers of bladder cancer: Sensitivity and specificity using trained sniffer dogs.

    PubMed

    Willis, Carolyn M; Britton, Lezlie E; Harris, Rob; Wallace, Joshua; Guest, Claire M

    In a previous canine study, we demonstrated that volatile organic compounds specific to bladder cancer are present in urine headspace, subsequently showing that up to 70% of tumours can be correctly classified using an electronic nose. This study aimed to evaluate the sensitivity and specificity which can be achieved by a group of four trained dogs. In a series of 30 double-blind test runs, each consisting of one bladder cancer urine sample placed alongside six controls, the highest sensitivity achieved by the best performing dog was 73% (95% CI 55-86%), with the group as a whole correctly identifying the cancer samples 64% (95% CI 55-73%) of the time. Specificity of the dogs individually ranged from 92% (95% CI 82-97%) for urine samples obtained from healthy, young volunteers down to 56% (95% CI 42-68%) for those taken from older patients with non-cancerous urological disease. Odds ratio comparisons confirmed a significant decrease in performance as the extent of urine dipstick abnormality and/or pathology amongst the control population increased. Importantly, however, statistical analysis indicated that covariates such as smoking, gender and age, as well as blood, protein and /or leucocytes in the urine did not significantly alter the odds of response to the cancer samples. Our results provide further evidence that volatile biomarkers for bladder cancer exist in urine headspace, and that these have the potential to be exploited for diagnosis.

  6. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  7. The effect of diet enriched with rapeseed meal on endogenous thiouracil contents in urine and milk of cattle.

    PubMed

    Wozniak, Barbara; Matraszek-Zuchowska, Iwona; Witek, Sebastian; Zmudzki, Jan; Posyniak, Andrzej

    2018-01-15

    Thyreostatic compounds, such as thiouracil, are orally active drugs that can be used to increase the weight of cattle before slaughter. Due to potentially teratogenic and carcinogenic effects of their residues on public health, the use of thyreostats in animal production has been banned in the European Union since 1981. Systematic detection of low concentrations of thiouracil in the urine of livestock in many countries is believed to be of endogenous origin due to the use of Brassicaceae plants in the animal diet. Therefore, the purpose of the study was to determine the effects of diets rich in rapeseed meal on formation of thiouracil in urine and milk of dairy cows. For two weeks three cows were subjected to a diet supplemented with rapeseed at 30%, compared to the control cattle diet which contained up to 11% rapeseed. During the experiment, samples of urine and milk were collected and analysed by LC-MS/MS. The increase and decrease of thiouracil concentration in urine samples in different animals was individual and cyclic. The highest concentration of natural thiouracil determined in urine was 3.61 μg l -1 . It has been found that endogenous thiouracil exists in two tautomeric forms. A few days of storage of frozen urine samples affected the stability of natural thiouracil, whereas an acidic medium improved the stability of the compound and its isomer, which remained stable even after two months of storage at temperatures below -18°C. Due to the instability of thiouracil, urine samples upon sampling should be delivered to the laboratory as soon as possible or properly preserved. In milk samples, thiouracil was not found above the decision limit of the applied method of 0.63 μg l -1 . Preliminary studies have shown that faecal examination for banned thiouracil can be a complementary test for urine samples, and may be helpful in determining the origin of the compound present in urine.

  8. Comparative analysis of detection methods for congenital cytomegalovirus infection in a Guinea pig model.

    PubMed

    Park, Albert H; Mann, David; Error, Marc E; Miller, Matthew; Firpo, Matthew A; Wang, Yong; Alder, Stephen C; Schleiss, Mark R

    2013-01-01

    To assess the validity of the guinea pig as a model for congenital cytomegalovirus (CMV) infection by comparing the effectiveness of detecting the virus by real-time polymerase chain reaction (PCR) in blood, urine, and saliva. Case-control study. Academic research. Eleven pregnant Hartley guinea pigs. Blood, urine, and saliva samples were collected from guinea pig pups delivered from pregnant dams inoculated with guinea pig CMV. These samples were then evaluated for the presence of guinea pig CMV by real-time PCR assuming 100% transmission. Thirty-one pups delivered from 9 inoculated pregnant dams and 8 uninfected control pups underwent testing for guinea pig CMV and for auditory brainstem response hearing loss. Repeated-measures analysis of variance demonstrated no statistically significantly lower weight for the infected pups compared with the noninfected control pups. Six infected pups demonstrated auditory brainstem response hearing loss. The sensitivity and specificity of the real-time PCR assay on saliva samples were 74.2% and 100.0%, respectively. The sensitivity of the real-time PCR on blood and urine samples was significantly lower than that on saliva samples. Real-time PCR assays of blood, urine, and saliva revealed that saliva samples show high sensitivity and specificity for detecting congenital CMV infection in guinea pigs. This finding is consistent with recent screening studies in human newborns. The guinea pig may be a good animal model in which to compare different diagnostic assays for congenital CMV infection.

  9. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.; Dietz, M.; Kaminski, M.

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less

  10. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  11. Urinary Virome Perturbations in Kidney Transplantation.

    PubMed

    Sigdel, Tara K; Mercer, Neil; Nandoe, Sharvin; Nicora, Carrie D; Burnum-Johnson, Kristin; Qian, Wei-Jun; Sarwal, Minnie M

    2018-01-01

    The human microbiome is important for health and plays a role in essential metabolic functions and protection from certain pathogens. Conversely, dysbiosis of the microbiome is seen in the context of various diseases. Recent studies have highlighted that a complex microbial community containing hundreds of bacteria colonizes the healthy urinary tract, but little is known about the human urinary viruses in health and disease. To evaluate the human urinary virome in the context of kidney transplantation (tx), variations in the composition of the urinary virome were evaluated in urine samples from normal healthy volunteers as well as patients with kidney disease after they had undergone kidney tx. Liquid chromatography-mass spectrometry/mass spectrometry analysis was undertaken on a selected cohort of 142 kidney tx patients and normal healthy controls, from a larger biobank of 770 kidney biopsy matched urine samples. In addition to analysis of normal healthy control urine, the cohort of kidney tx patients had biopsy confirmed phenotype classification, coincident with the urine sample analyzed, of stable grafts (STA), acute rejection, BK virus nephritis, and chronic allograft nephropathy. We identified 37 unique viruses, 29 of which are being identified for the first time in human urine samples. The composition of the human urinary virome differs in health and kidney injury, and the distribution of viral proteins in the urinary tract may be further impacted by IS exposure, diet and environmental, dietary, or cutaneous exposure to various insecticides and pesticides.

  12. Determining the authenticity of athlete urine in doping control by DNA analysis.

    PubMed

    Devesse, Laurence; Syndercombe Court, Denise; Cowan, David

    2015-10-01

    The integrity of urine samples collected from athletes for doping control is essential. The authenticity of samples may be contested, leading to the need for a robust sample identification method. DNA typing using short tandem repeats (STR) can be used for identification purposes, but its application to cellular DNA in urine has so far been limited. Here, a reliable and accurate method is reported for the successful identification of urine samples, using reduced final extraction volumes and the STR multiplex kit, Promega® PowerPlex ESI 17, with capillary electrophoretic characterisation of the alleles. Full DNA profiles were obtained for all samples (n = 20) stored for less than 2 days at 4 °C. The effect of different storage conditions on yield of cellular DNA and probability of obtaining a full profile were also investigated. Storage for 21 days at 4 °C resulted in allelic drop-out in some samples, but the random match probabilities obtained demonstrate the high power of discrimination achieved through targeting a large number of STRs. The best solution for long-term storage was centrifugation and removal of supernatant prior to freezing at -20 °C. The method is robust enough for incorporation into current anti-doping protocols, and was successfully applied to 44 athlete samples for anti-doping testing with 100% concordant typing. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Proximal tubule proteins are significantly elevated in bladder urine of patients with ureteropelvic junction obstruction and may represent novel biomarkers: A pilot study.

    PubMed

    Gerber, Claire; Harel, Miriam; Lynch, Miranda L; Herbst, Katherine W; Ferrer, Fernando A; Shapiro, Linda H

    2016-04-01

    Ureteropelvic junction obstruction (UPJO) is the major cause of hydronephrosis in children and may lead to renal injury and early renal dysfunction. However, diagnosis of the degree of obstruction and severity of renal injury relies on invasive and often inconclusive renal scans. Biomarkers from voided urine that detect early renal injury are highly desirable because of their noninvasive collection and their potential to assist in earlier and more reliable diagnosis of the severity of obstruction. Early in response to UPJO, increased intrarenal pressure directly impacts the proximal tubule brush border. We hypothesize that single-pass, apically expressed proximal tubule brush border proteins will be shed into the urine early and rapidly and will be reliable noninvasive urinary biomarkers, providing the tools for a more reliable stratification of UPJO patients. We performed a prospective cohort study at Connecticut Children's Medical Center. Bladder urine samples from 12 UPJO patients were obtained prior to surgical intervention. Control urine samples were collected from healthy pediatric patients presenting with primary nocturnal enuresis. We determined levels of NGAL, KIM-1 (previously identified biomarkers), CD10, CD13, and CD26 (potentially novel biomarkers) by ELISA in control and experimental urine samples. Urinary creatinine levels were used to normalize the urinary protein levels measured by ELISA. Each of the proximal tubule proteins outperformed the previously published biomarkers. No differences in urinary NGAL and KIM-1 levels were observed between control and obstructed patients (p = 0.932 and p = 0.799, respectively). However, levels of CD10, CD13, and CD26 were significantly higher in the voided urine of obstructed individuals when compared with controls (p = 0.002, p = 0.024, and p = 0.007, respectively) (Figure). Targeted identification of reliable, noninvasive biomarkers of renal injury is critical to aid in diagnosing patients at risk, guiding therapeutic decisions and monitoring treatment efficacy. Proximal tubule brush border proteins are reliably detected in the urine of obstructed patients and may be more effective at predicting UPJO. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  14. Urinary Volatile Organic Compounds for the Detection of Prostate Cancer

    PubMed Central

    Khalid, Tanzeela; Aggio, Raphael; White, Paul; De Lacy Costello, Ben; Persad, Raj; Al-Kateb, Huda; Jones, Peter; Probert, Chris S.; Ratcliffe, Norman

    2015-01-01

    The aim of this work was to investigate volatile organic compounds (VOCs) emanating from urine samples to determine whether they can be used to classify samples into those from prostate cancer and non-cancer groups. Participants were men referred for a trans-rectal ultrasound-guided prostate biopsy because of an elevated prostate specific antigen (PSA) level or abnormal findings on digital rectal examination. Urine samples were collected from patients with prostate cancer (n = 59) and cancer-free controls (n = 43), on the day of their biopsy, prior to their procedure. VOCs from the headspace of basified urine samples were extracted using solid-phase micro-extraction and analysed by gas chromatography/mass spectrometry. Classifiers were developed using Random Forest (RF) and Linear Discriminant Analysis (LDA) classification techniques. PSA alone had an accuracy of 62–64% in these samples. A model based on 4 VOCs, 2,6-dimethyl-7-octen-2-ol, pentanal, 3-octanone, and 2-octanone, was marginally more accurate 63–65%. When combined, PSA level and these four VOCs had mean accuracies of 74% and 65%, using RF and LDA, respectively. With repeated double cross-validation, the mean accuracies fell to 71% and 65%, using RF and LDA, respectively. Results from VOC profiling of urine headspace are encouraging and suggest that there are other metabolomic avenues worth exploring which could help improve the stratification of men at risk of prostate cancer. This study also adds to our knowledge on the profile of compounds found in basified urine, from controls and cancer patients, which is useful information for future studies comparing the urine from patients with other disease states. PMID:26599280

  15. Effects of Agitation and Storage Temperature on Measurements of Hydration Status.

    PubMed

    Adams, Heather M; Eberman, Lindsey E; Yeargin, Susan W; Niemann, Andrew J; Mata, Heather L; Dziedzicki, David J

    2015-12-01

    Hypohydration can have significant implications on normal physiological functions of the body. This study aimed to determine the impact of agitation, storage temperature, and storage time on urine osmolality compared to the criterion control. We used a descriptive diagnostic validity test design. To investigate agitation, we recruited 75 healthy individuals (males = 41, females = 34; mean age = 22 ± 5 years; mean self-reported height = 172 ± 23 cm and mass = 77 ± 17 kg) who provided one or more samples (total = 81). The independent variables were agitation (vortex, hand shaken, no agitation) and temperature (room temperature, freezer, and refrigerator) type. Participants completed informed consent, a health questionnaire and were asked to provide a urine sample, which was split and labeled according to agitation type or storage temperature. Urine osmolality was used to determine hydration status at two time points (within 2 hours [control], 48 hours). We used t-tests to determine the difference between each condition and the control and calculated percent error for each condition. No significant differences for no agitation (t79 = -0.079, P = 0.937), hand shaken (t79 = 1.395, P = 0.167) or vortex mixed (t79 = -0.753, P = 0.453) were identified when compared to the criterion control. No significant differences for room temperature (t82 = -0.720, P = 0.474), refrigerator (t82 = -2.697, P = 0.008) or freezer (t82 = 2.576, P = 0.012) were identified when compared to the criterion control. Our findings suggest agitation of urine specimen is not necessary and samples do not require refrigeration or freezing if assessed within 48 hours. Analysis within two hours of collection is not necessary and samples can be stored for up to 48 hours without impacting the hydration status of the sample.

  16. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  17. Bladder cancer biomarker discovery using global metabolomic profiling of urine.

    PubMed

    Wittmann, Bryan M; Stirdivant, Steven M; Mitchell, Matthew W; Wulff, Jacob E; McDunn, Jonathan E; Li, Zhen; Dennis-Barrie, Aphrihl; Neri, Bruce P; Milburn, Michael V; Lotan, Yair; Wolfert, Robert L

    2014-01-01

    Bladder cancer (BCa) is a common malignancy worldwide and has a high probability of recurrence after initial diagnosis and treatment. As a result, recurrent surveillance, primarily involving repeated cystoscopies, is a critical component of post diagnosis patient management. Since cystoscopy is invasive, expensive and a possible deterrent to patient compliance with regular follow-up screening, new non-invasive technologies to aid in the detection of recurrent and/or primary bladder cancer are strongly needed. In this study, mass spectrometry based metabolomics was employed to identify biochemical signatures in human urine that differentiate bladder cancer from non-cancer controls. Over 1000 distinct compounds were measured including 587 named compounds of known chemical identity. Initial biomarker identification was conducted using a 332 subject sample set of retrospective urine samples (cohort 1), which included 66 BCa positive samples. A set of 25 candidate biomarkers was selected based on statistical significance, fold difference and metabolic pathway coverage. The 25 candidate biomarkers were tested against an independent urine sample set (cohort 2) using random forest analysis, with palmitoyl sphingomyelin, lactate, adenosine and succinate providing the strongest predictive power for differentiating cohort 2 cancer from non-cancer urines. Cohort 2 metabolite profiling revealed additional metabolites, including arachidonate, that were higher in cohort 2 cancer vs. non-cancer controls, but were below quantitation limits in the cohort 1 profiling. Metabolites related to lipid metabolism may be especially interesting biomarkers. The results suggest that urine metabolites may provide a much needed non-invasive adjunct diagnostic to cystoscopy for detection of bladder cancer and recurrent disease management.

  18. A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.

    PubMed

    Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera

    2015-10-01

    The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.

  19. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. The use of laser-induced fluorescence or ultraviolet detectors for sensitive and selective analysis of tobramycin or erythropoietin in complex samples

    NASA Astrophysics Data System (ADS)

    Ahmed, Hytham M.; Ebeid, Wael B.

    2015-05-01

    Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.

  1. Evaluation of biomarkers in plasma, blood, and urine samples from coke oven workers: significance of exposure to polycyclic aromatic hydrocarbons.

    PubMed Central

    Ovrebø, S; Haugen, A; Farmer, P B; Anderson, D

    1995-01-01

    OBJECTIVE--The aim was to assess the significance of two biomarkers; antibody to benzo(a)pyrene DNA adducts and concentration of hydroxyethylvaline haemoglobin adducts in samples from a well studied group of coke oven workers. As a measure of exposure we have used 1-hydroxypyrene in urine. METHODS--Urine and blood samples were collected from coke oven workers and a control group. Samples from coke oven plant workers were collected in January and June. 1-Hydroxypyrene was measured in urine by high performance liquid chromatography (HPLC), antibodies to benzo(a)pyrene DNA adducts were measured by ELISA and hydroxyethylvaline haemoglobin adducts were measured by gas chromatography-mass spectrometry (GC-MS). RESULTS--Mean urinary 1-hydroxypyrene in samples from coke oven workers varied from 1.11 to 5.53 umol/mol creatinine and 0.14 umol/mol creatinine in the control group. Workers at the top side had the highest values of urinary 1-hydroxypyrene. Antibody to benzo(a)pyrene DNA adducts did not correlate with either 1-hydroxypyrene nor length of work at the coke oven plant. But antibody concentration in samples collected in January was predictive of the concentration in samples collected in June. A small non-significant increase in hydroxyethylvaline haemoglobin adducts was found in samples from coke oven workers relative to the control group when comparing smokers and nonsmokers separately. CONCLUSION--1-Hydroxypyrene correlates well with exposure groups based on job description. Antibodies to benzo(a)-pyrene DNA adducts was related to people and not exposure. Work at a coke oven plant might lead to increased hydroxyethylvaline haemoglobin adducts. PMID:8535495

  2. Vasopressin, cortisol, and catecholamine concentrations in dogs with dilated cardiomyopathy.

    PubMed

    Tidholm, Anna; Häggström, Jens; Hansson, Kerstin

    2005-10-01

    To evaluate plasma concentrations and urinary excretion of vasopressin and cortisol and urinary excretion of catecholamines in dogs with dilated cardiomyopathy (DCM). 15 dogs with clinical signs of DCM, 15 dogs with preclinical DCM, and 15 control dogs. Physical examinations, thoracic radiography, ECG, and echocardiography were performed on all dogs. Blood and urine samples were collected. Plasma concentration of vasopressin and the urine cortisol-to-urine creatinine ratio were significantly increased in dogs with clinical signs of DCM and dogs with preclinical DCM, compared with control dogs. Plasma vasopressin concentration was significantly higher in dogs with clinical signs of DCM, compared with dogs with preclinical DCM. Urine vasopressin-to-urine creatinine ratio was significantly increased in dogs with clinical signs of DCM, compared with dogs with preclinical DCM and control dogs. Urine epinephrine-to-urine creatinine ratio and urine norepinephrine-to-urine creatinine ratio were significantly increased in dogs with clinical signs of DCM, compared with control dogs. Plasma concentration of cortisol and urine dopamine-to-urine creatinine ratio did not differ significantly among groups. According to this study, the neuroendocrine pattern is changed in dogs with preclinical DCM. These changes are even more pronounced in dogs with clinical signs of DCM. Analysis of concentrations of vasopressin, cortisol, and catecholamines may aid in identification of the clinical stages of DCM. These findings may also provide a basis for additional studies of the possible beneficial effects of vasopressin antagonists and beta-adrenergic receptor antagonists in the treatment of dogs with congestive heart failure and DCM.

  3. Evaluation of the results of Mycobacterium tuberculosis direct test (MTD) and Mycobacterial culture in urine samples

    PubMed Central

    Sener, Asli Gamze; Kurultay, Nukhet; Afsar, Ilhan

    2008-01-01

    Tuberculosis remains a public health problem in Turkey. Rapid detection of Mycobacterium tuberculosis plays a key role in control of infection. In this article, the Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test (MTD) was evaluated for detection of M. tuberculosis in urine samples. The performance of the MTD was very good and appropriate for routine laboratory diagnosis. PMID:24031287

  4. Stamping SERS for creatinine sensing

    NASA Astrophysics Data System (ADS)

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan

    2015-03-01

    Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.

  5. Neonicotinoid concentrations in urine from chronic kidney disease patients in the North Central Region of Sri Lanka.

    PubMed

    Kabata, Risako; Nanayakkara, Shanika; Senevirathna, Stmld; Harada, Kouji H; Chandrajith, Rohana; Hitomi, Toshiaki; Abeysekera, Tilak; Takasuga, Takumi; Koizumi, Akio

    2016-01-01

    Neonicotinoid insecticides have been widely used around the world since the 1990s. Reports have been made since the 1990s of rice paddy farmers in the North Central Region (NCR) of Sri Lanka suffering from chronic kidney disease with unknown etiology (CKDu). A preliminary evaluation of the exposure of local farmers in the NCR of Sri Lanka to neonicotinoids was performed. We analyzed neonicotinoid and neonicotinoid metabolite concentrations in spot urine samples. We selected 40 samples, 10 from farmers with CKDu and 10 from controls from each of two areas, Medawachchiya and Girandurukotte. Imidacloprid and desmethyl-acetamiprid were found at significantly higher concentrations in the control samples (with medians of 51 ng/l and 340 ng/l, respectively) than in the CKDu samples (medians of 15 ng/l and 150 ng/l, respectively) when the results were not adjusted for the creatinine contents. None of the six compounds that were measured in the urine samples were found at significantly higher concentrations in the CKDu samples than in the control samples. None of the neonicotinoid concentrations in the samples analyzed in this study exceeded the concentrations that have been found in samples from the general population of Japan. Farmers (both with and without CKDu) living in CKDu-endemic areas in the NCR of Sri Lanka are exposed to lower neonicotinoid concentrations than non-occupationally exposed residents of Japan.

  6. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    PubMed

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  7. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HANDLING QUALITY CONTROL SAMPLES IN THE FIELD (RTI/ACS-AP-209-090)

    EPA Science Inventory

    This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...

  8. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    PubMed

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  9. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases

    PubMed Central

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-01

    AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869

  10. Elevated Urine Levels of Macrophage Migration Inhibitory Factor in Inflammatory Bladder Conditions: A Potential Biomarker for a Subgroup of Interstitial Cystitis/Bladder Pain Syndrome Patients.

    PubMed

    Vera, Pedro L; Preston, David M; Moldwin, Robert M; Erickson, Deborah R; Mowlazadeh, Behzad; Ma, Fei; Kouzoukas, Dimitrios E; Meyer-Siegler, Katherine L; Fall, Magnus

    2018-06-01

    To investigate whether urinary levels of macrophage migration inhibitory factor (MIF) are elevated in interstitial cystitis/bladder pain syndrome (IC/BPS) patients with Hunner lesions and also whether urine MIF is elevated in other forms of inflammatory cystitis. Urine samples were assayed for MIF by enzyme-linked immunosorbent assay. Urine samples from 3 female groups were examined: IC/BPS patients without (N = 55) and with Hunner lesions (N = 43), and non-IC/BPS patients (N = 100; control group; no history of IC/BPS; cancer or recent bacterial cystitis). Urine samples from 3 male groups were examined: patients with bacterial cystitis (N = 50), radiation cystitis (N = 18) and noncystitis patients (N = 119; control group; negative for bacterial cystitis). Urine MIF (mean MIF pg/mL ±  standard error of the mean) was increased in female IC/BPS patients with Hunner lesions (2159 ± 435.3) compared with IC/BPS patients without Hunner lesions (460 ± 114.5) or non-IC/BPS patients (414 ± 47.6). Receiver operating curve analyses showed that urine MIF levels discriminated between the 2 IC groups (area under the curve = 72%; confidence interval 61%-82%). Male patients with bacterial and radiation cystitis had elevated urine MIF levels (2839 ± 757.1 and 4404 ± 1548.1, respectively) compared with noncystitis patients (681 ± 75.2). Urine MIF is elevated in IC/BPS patients with Hunner lesions and also in patients with other bladder inflammatory and painful conditions. MIF may also serve as a noninvasive biomarker to select IC/BPS patients more accurately for endoscopic evaluation and possible anti-inflammatory treatment. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Use of immunoblotting to detect Aspergillus fumigatus antigen in sera and urines of rats with experimental invasive aspergillosis.

    PubMed Central

    Yu, B; Niki, Y; Armstrong, D

    1990-01-01

    Immunoblotting was used to detect Aspergillus fumigatus antigen in sera and urines of immunosuppressed rats experimentally infected with A. fumigatus. Organisms were administered by both intravenous and intratracheal injections. Intravenously infected rats developed disseminated aspergillosis, but intratracheally infected rats developed pulmonary disease only. Fungal cultures of blood and urine samples from infected rats were negative. In the urines of intravenously infected rats, antigen was detected 24 to 48 h after infection; in the urines of intratracheally infected animals, antigen was detected on days 4 to 5 after infection. Antigen in serum was detected later than antigen in urine was. Following sodium dodecyl sulfate-polyacrylamide gel electrophoresis and immunoblotting of serum and urine samples, the most strongly reacting antigenic materials were found in the 88-, 40-, 27-, and 20-kilodalton regions. These dominant antigens appeared to be the same as those of control antigens prepared from A. fumigatus grown in vitro. Rabbit antiserum to Aspergillus filtrate antigen was found to be more immunoreactive than antiserum to mycelial or conidial antigen. No mycelium-specific antigens were detected. Images PMID:2199519

  12. Preliminary study on application of urine amino acids profiling for monitoring of renal tubular injury using GLC-MS.

    PubMed

    Kazubek-Zemke, Maja; Rybka, Jacek; Marchewka, Zofia; Rybka, Wojciech; Pawlik, Krzysztof; Długosz, Anna

    2014-11-14

    The early diagnosis of the nephrotoxic effect of xenobiotics and drugs is still an unsolved problem. Recent studies suggest a correlation between the nephrotoxic activity of xenobiotics and increased concentration of amino acids in urine. The presented study was focused on the application of GLC-MS method for amino acids profiling in human urine as a noninvasive method for monitoring of kidney condition and tubular injury level. The analytic method is based on the conversion of the amino acids present in the sample to tert-butyldimethylsilyl (TBDMS) derivatives and their analysis by gas-liquid chromatography-mass spectrometry (GLC-MS). The procedure of urine sample preparation for chromatographic analysis was optimized. The presence of 12 amino acids in most of the tested healthy human urine samples was detected. The significant differences in the levels of particular amino acids between patients with tubular injury and healthy controls were found, especially for lysine, valine, serine, alanine and leucine (on average 30.0, 7.5, 3.6, 2.9 and 0.5 fold respectively). We found that this approach based on GLC-MS detection can be used in nephrotoxicity studies for urine amino acids monitoring in exposure to xenobiotics and drugs.

  13. Detection and quantification of rituximab in the human urine.

    PubMed

    Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario

    2017-12-01

    B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Prednisolone and prednisone neo-formation in bovine urine after sampling.

    PubMed

    Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G

    2012-06-01

    The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.

  15. Albumin testing in urine using a smart-phone

    PubMed Central

    Coskun, Ahmet F.; Nagi, Richie; Sadeghi, Kayvon; Phillips, Stephen; Ozcan, Aydogan

    2013-01-01

    We demonstrate a digital sensing platform, termed Albumin Tester, running on a smart-phone that images and automatically analyses fluorescent assays confined within disposable test tubes for sensitive and specific detection of albumin in urine. This light-weight and compact Albumin Tester attachment, weighing approximately 148 grams, is mechanically installed on the existing camera unit of a smart-phone, where test and control tubes are inserted from the side and are excited by a battery powered laser diode. This excitation beam, after probing the sample of interest located within the test tube, interacts with the control tube, and the resulting fluorescent emission is collected perpendicular to the direction of the excitation, where the cellphone camera captures the images of the fluorescent tubes through the use of an external plastic lens that is inserted between the sample and the camera lens. The acquired fluorescent images of the sample and control tubes are digitally processed within one second through an Android application running on the same cellphone for quantification of albumin concentration in urine specimen of interest. Using a simple sample preparation approach which takes ~ 5 minutes per test (including the incubation time), we experimentally confirmed the detection limit of our sensing platform as 5–10 μg/mL (which is more than 3 times lower than clinically accepted normal range) in buffer as well as urine samples. This automated albumin testing tool running on a smart-phone could be useful for early diagnosis of kidney disease or for monitoring of chronic patients, especially those suffering from diabetes, hypertension, and/or cardiovascular diseases. PMID:23995895

  16. The use of laser-induced fluorescence or ultraviolet detectors for sensitive and selective analysis of tobramycin or erythropoietin in complex samples.

    PubMed

    Ahmed, Hytham M; Ebeid, Wael B

    2015-05-15

    Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200ng/ml respectively and recovery was >98% (n=5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Influence of respiratory tract disease and mode of inhalation on detectability of budesonide in equine urine and plasma.

    PubMed

    Barton, Ann Kristin; Heinemann, Henrike; Schenk, Ina; Machnik, Marc; Gehlen, Heidrun

    2017-02-01

    OBJECTIVE To evaluate the influence of respiratory tract disease (ie, recurrent airway obstruction [RAO]) and mode of inhalation on detectability of inhaled budesonide in equine plasma and urine samples. ANIMALS 16 horses (8 healthy control horses and 8 horses affected by RAO, as determined by results of clinical examination, blood gas analysis, bronchoscopy, and cytologic examination of bronchoalveolar lavage fluid). PROCEDURES 4 horses of each group inhaled budesonide (3 μg/kg) twice daily for 10 days while at rest, and the remaining 4 horses of each group inhaled budesonide during lunging exercise. Plasma and urine samples were obtained 4 to 96 hours after inhalation and evaluated for budesonide and, in urine samples, the metabolites 6β-hydroxybudesonide and 16α-hydroxyprednisolone. RESULTS Detected concentrations of budesonide were significantly higher at all time points for RAO-affected horses, compared with concentrations for the control horses. All samples of RAO-affected horses contained budesonide concentrations above the limit of detection at 96 hours after inhalation, whereas this was found for only 2 control horses. Detected concentrations of budesonide were higher, but not significantly so, at all time points in horses that inhaled budesonide during exercise, compared with concentrations for inhalation at rest. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that the time interval between inhalation of a glucocorticoid and participation in sporting events should be increased when inhalation treatment is administered during exercise to horses affected by respiratory tract disease.

  18. A pilot study of urinary microRNA as a biomarker for urothelial cancer

    PubMed Central

    Snowdon, Jaime; Boag, Sandy; Feilotter, Harriet; Izard, Jason; Siemens, D. Robert

    2013-01-01

    Objective: MicroRNAs (miRNAs) are part of a class of small ribonucleic acid (RNAs). They are important regulatory molecules, involved in several cell processes, such as developmental timing, stem cell division and apoptosis. Dysregulated miRNAs have been identified in several human malignancies, including bladder cancer tissue samples, and may confer a “tumour signature” that can be exploited for diagnostic purposes. We report on a prospective pilot study investigating the diagnostic capability of miRNAs in the urine of patients with urothelial cancer. Methods: Voided urine samples were collected from patients with urothelial carcinoma just prior to bladder tumour resection, as well as age-matched healthy control patients. Pathology demonstrated both low- and high-grade cancer. Total RNA was isolated and quantitative reverse transcriptase-polymerase chain reaction was performed on the RNA extracts using primers for 4 miRNAs shown previously to be dysregulated in solid urothelial carcinomas with RNU6B as the endogenous control. Standard urine cytology was performed on all samples in a blinded fashion. Results: Two miRNAs of interest were dysregulated in the urine from cancer patients with miR-125b showing an average 10.42-fold decrease (p < 0.01) and miR-126 showing an average 2.70-fold increase (p = 0.30) in the cancer samples compared to the normal controls. The sensitivity and specificity of the cytology on the same urine samples were 50% and 80%, respectively. Using these 2 miRNAs only, a decision-tree prediction model was generated for a validation cohort of patients yielding a specificity of 100% and a sensitivity of 80%. Discussion: This preliminary study of candidate urinary miRNA in patients with low- and high-grade urothelial cancer demonstrated a significantly improved diagnostic accuracy over cytology. These results provide rationale for further studies on discovery and validation of candidate miRNAs in voided urine and may potentially lead to the development of a non-invasive and sensitive test for bladder cancer diagnosis and prognosis. PMID:22630336

  19. Pethidinic acid: corroboration of a doctor's denial of pethidine re-use.

    PubMed

    Lewis, John; Shimmon, Ronald; Fu, Shanlin

    2013-04-01

    Pethidine (meperidine), a synthetic opiate, formally used as an analgesic in surgery and obstetrics, has been an abused drug of choice for some doctors. A case is presented in which a doctor, who previously admitted to using pethidine, was suspected of re-using, following a second positive urine test. A laboratory had reported the presence of pethidine in the doctor's urine; however, the doctor denied re-use. The norpethidine (normeperidine) metabolite, normally found in urine, had not been detected, raising concern over the laboratory's conclusion and necessitating an independent investigation. Because the major metabolite of pethidine is pethidinic acid (meperidinic acid), accounting for approximately 40% of the excreted dose, its presence or absence were deemed to be important criteria in interpreting the laboratory result. Pethidinic acid was synthesized by alkaline hydrolysis of pethidine and used as a control. Urine samples from a patient receiving pethidine for pain, from the previous pethidine use of the doctor, and the urine under question plus the control were analyzed for the presence of pethidinic acid using electrospray mass spectrometry. Pethidinic acid was found in all samples except the one under dispute. The absence of pethidinic acid appeared to corroborate the doctor's denial of re-use.

  20. Mutagenicity of urine from individuals exposed to LPG combustion products.

    PubMed

    Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X

    1998-09-01

    The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.

  1. Results of the Excreta Bioassay Quality Control Program for April 1, 2009 through March 31, 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonio, Cheryl L.

    2012-07-19

    A total of 58 urine samples and 10 fecal samples were submitted during the report period (April 1, 2009 through March 31, 2010) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year as well as four tissue samples for 238Pu, 239Pu, 241Am and 241Pu. The number of QC urine samples submitted during the report period represented 1.3% of the total samplesmore » submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 33% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4).« less

  2. Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonio, Cheryl L.

    2012-07-19

    A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238Pu, 239Pu, 241Am, 243Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted. In addition to the samples provided by IDP,more » GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 31% of the analyses processed by GEL during the first year of contract 112512 were quality control samples. GEL tested the performance of 23 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty except the slightly elevated relative bias for 243,244Cm (Table 4).« less

  3. Antibiotic use in heavy pigs: Comparison between urine and muscle samples from food chain animals analysed by HPLC-MS/MS.

    PubMed

    Chiesa, Luca Maria; Nobile, Maria; Panseri, Sara; Arioli, Francesco

    2017-11-15

    The antibiotic overuse in zoothechnics, due to prophylactic and therapeutic treatments, or to their growth-promoting activity, is a major cause for the onset of widespread antibiotic resistance. Of particular relevance to this study, is the antibiotic abuse in pig breeding. Despite the comprehensive literature on residue controls in pig muscle, data on pig urine, a non-invasive, on-farm collectable matrix, are lacking. Therefore, we validated an HPLC-MS/MS method to detect 29 antimicrobials from eight classes and applied it to 43 anonymous pig urine and muscle paired samples and fulfilled the parameters in agreement with the Commission Decision 2002/657/UE. The analytical limits were moreover much lower than the maximum residue limits (MRLs) required by the Commission Regulation 37/2010/UE. In the samples, antibiotics were usually detected at higher frequencies and concentrations in urine than muscle. Urine proved a useful tool to detect antibiotic administration and their excessive use in pig farming is depicted. Copyright © 2017. Published by Elsevier Ltd.

  4. Evaluation of open versus closed urine collection systems and development of nosocomial bacteriuria in dogs.

    PubMed

    Sullivan, Lauren A; Campbell, Vicki L; Onuma, Serene C

    2010-07-15

    To determine whether use of a closed urine collection system would decrease the incidence of nosocomial bacteriuria in hospitalized dogs, compared with use of an open urine collection system (used, sterile IV bags). Randomized controlled trial. 51 hospitalized dogs requiring indwelling urinary catheterization for >or= 24 hours. Dogs were randomly assigned to an open or closed urine collection system group. A standardized protocol for catheter placement and maintenance was followed for all dogs. A baseline urine sample was collected via cystocentesis for aerobic bacterial culture, with additional urine samples obtained daily from the urine collection reservoir. 27 dogs were assigned to the open urine collection system group, and 24 were assigned to the closed urine collection system group. The incidence of nosocomial bacteriuria in dogs with open urine collection systems (3/27 [11.1%]) was not significantly different from incidence in dogs with closed urine collection systems (2/24 [8.3%]). Median duration of catheterization was 2 days for dogs in both groups; the range was 1 to 7 days for dogs in the open group and 1 to 5 days for dogs in the closed group. Results suggested that for dogs requiring short-term indwelling urinary catheterization, the type of urine collection system (open vs closed) was not associated with likelihood of developing nosocomial bacteriuria. Use of a strict protocol for urinary catheter placement and maintenance was likely key in the low incidence of nosocomial bacteriuria in the present study.

  5. Correlation of the levels of glycosaminoglycans between urine and dried urine in filter paper samples and their stability over time under different storage temperatures.

    PubMed

    Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro

    2014-06-10

    Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Early Detection of Pressure Ulcer Development Following Traumatic Spinal Cord Injury Using Inflammatory Mediators.

    PubMed

    Krishnan, Shilpa; Karg, Patricia E; Boninger, Michael L; Vodovotz, Yoram; Constantine, Greg; Sowa, Gwendolyn A; Brienza, David M

    2016-10-01

    To identify changes in concentrations of inflammatory mediators in plasma and urine after traumatic spinal cord injury (SCI) and before the occurrence of a first pressure ulcer. Retrospective; secondary analysis of existing data. Acute hospitalization and inpatient rehabilitation sites at a university medical center. Individuals with a pressure ulcer and plasma samples (n=17) and individuals with a pressure ulcer and urine samples (n=15) were matched by age and plasma/urine sample days to individuals with SCI and no pressure ulcer (N=35). Not applicable. Plasma and urine samples were assayed in patients with SCI, capturing samples within 4 days after the SCI to a week before the formation of the first pressure ulcer. The Wilcoxon signed-rank test was performed to identify changes in the inflammatory mediators between the 2 time points. An increase in concentration of the chemokine interferon-γ-induced protein of 10kd/CXCL10 in plasma (P<.01) and a decrease in concentration of the cytokine interferon-α in urine (P=.01) were observed before occurrence of a first pressure ulcer (∼4d) compared with matched controls. Altered levels of inflammatory mediators in plasma and urine may be associated with pressure ulcer development after traumatic SCI. These inflammatory mediators should be explored as possible biomarkers for identifying individuals at risk for pressure ulcer formation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Determination of modafinil in plasma and urine by reversed phase high-performance liquid-chromatography.

    PubMed

    Schwertner, Harvey A; Kong, Suk Bin

    2005-03-09

    Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.

  8. Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection.

    PubMed

    Hughes, D L; Ritter, D J; Wilson, R D

    2001-11-01

    Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.

  9. Development of a method which discriminates between endogenous and exogenous beta-boldenone.

    PubMed

    Blokland, M H; van Rossum, H J; Sterk, S S; van Ginkel, L A; Stephany, R W

    2007-03-14

    One potential explanation for the presence of beta-boldenone in calf urine is contamination of the sample with feces containing beta-boldenone. It has been demonstrated that after oral and intramuscular administration of beta-boldenone esters, several metabolites are formed and excreted in urine. One of the (minor) metabolites is 6beta-hydroxy-17alpha-boldenone. This paper describes an analytical method that can discriminate between unconjugated boldenone, its glucuronide- and sulphate-conjugates, 6beta-hydroxy-17alpha/beta-boldenone and coprostanol, a marker for fecal contamination. The method was applied to all samples suspected to contain boldenone within the Dutch National Residue Control Plan. Approximately 10,000 samples of urine were screened (LC-MS) in 2004-2005 by VWA-East, one of the official Dutch control laboratories, from which 261 samples were suspected to contain boldenone. These samples were all analyzed for their conjugation state, 6beta-hydroxy-17alpha/beta-boldenone and for the presence of coprostanol. Alfa-boldenone, the major metabolite in bovine urine after boldenone-ester administration, was found in a large number of these samples. The presence of alpha-boldenone was proven also to be a result of fecal contamination. None of the samples tested contained residues of the metabolite 6beta-hydroxy-17alpha/beta-boldenone. Not finding this metabolite indicates that the origin of alpha-boldenone-conjugates is endogenous. The results confirm that the presence of unconjugated beta-boldenone and alpha-boldenone conjugates next to alpha-boldenone are no indicators for illegal administration of boldenone-esters. No indications were obtained that conjugated beta-boldenone can be of endogenous origin.

  10. Stone former urine proteome demonstrates a cationic shift in protein distribution compared to normal.

    PubMed

    Kolbach-Mandel, Ann M; Mandel, Neil S; Hoffmann, Brian R; Kleinman, Jack G; Wesson, Jeffrey A

    2017-08-01

    Many urine proteins are found in calcium oxalate stones, yet decades of research have failed to define the role of urine proteins in stone formation. This urine proteomic study compares the relative amounts of abundant urine proteins between idiopathic calcium oxalate stone forming and non-stone forming (normal) cohorts to identify differences that might correlate with disease. Random mid-morning urine samples were collected following informed consent from 25 stone formers and 14 normal individuals. Proteins were isolated from urine using ultrafiltration. Urine proteomes for each sample were characterized using label-free spectral counting mass spectrometry, so that urine protein relative abundances could be compared between the two populations. A total of 407 unique proteins were identified with the 38 predominant proteins accounting for >82% of all sample spectral counts. The most highly abundant proteins were equivalent in stone formers and normals, though significant differences were observed in a few moderate abundance proteins (immunoglobulins, transferrin, and epidermal growth factor), accounting for 13 and 10% of the spectral counts, respectively. These proteins contributed to a cationic shift in protein distribution in stone formers compared to normals (22% vs. 18%, p = 0.04). Our data showing only small differences in moderate abundance proteins suggest that no single protein controls stone formation. Observed increases in immunoglobulins and transferrin suggest increased inflammatory activity in stone formers, but cannot distinguish cause from effect in stone formation. The observed cationic shift in protein distribution would diminish protein charge stabilization, which could lead to protein aggregation and increased risk for crystal aggregation.

  11. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

    PubMed

    Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas

    2007-01-01

    Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.

  12. High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry.

    PubMed

    Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert

    2009-01-01

    An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.

  13. Monitoring 2-phenylethanamine and 2-(3-hydroxyphenyl)acetamide sulfate in doping controls.

    PubMed

    Sigmund, Gerd; Dib, Josef; Tretzel, Laura; Piper, Thomas; Bosse, Christina; Schänzer, Wilhelm; Thevis, Mario

    2015-01-01

    2-Phenylethanamine (phenethylamine, PEA) represents the core structure of numerous drugs with stimulant-like properties and is explicitly featured as so-called specified substance on the World Anti-Doping Agency (WADA) Prohibited List. Due to its natural occurrence in humans as well as its presence in dietary products, studies concerning the ability of test methods to differentiate between an illicit intake and the renal elimination of endogenously produced PEA were indicated. Following the addition of PEA to the Prohibited List in January 2015, retrospective evaluation of routine doping control data of 10 190 urine samples generated by combined gas chromatography-mass spectrometry and nitrogen phosphorus-specific detection (GC-MS/NPD) was performed. Signals for PEA at approximate concentrations > 500 ng/mL were observed in 31 cases (0.3%), which were subjected to a validated isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) test method for accurate quantification of the target analyte. Further, using elimination study urine samples collected after a single oral administration of 250 mg of PEA hydrochloride to two healthy male volunteers, two tentatively identified metabolites of PEA were observed and evaluated concerning their utility as discriminative markers for PEA intake. The ID-LC-MS/MS approach was extended to allow for the simultaneous detection of PEA and 2-(3-hydroxyphenyl)acetamide sulfate (M1), and concentration ratios of M1 and PEA were calculated for elimination study urine samples and a total of 205 doping control urine samples that returned findings for PEA at estimated concentrations of 50-2500 ng/mL. Urine samples of the elimination study with PEA yielded concentration ratios of M1/PEA up to values of 9.4. Notably, the urinary concentration of PEA did increase with the intake of PEA only to a modest extent, suggesting a comprehensive metabolism of the orally administered substance. Conversely, doping control urine samples with elevated (>50 ng/mL) amounts of PEA returned quantifiable concentrations of M1 only in 3 cases, which yielded maximum ratios of M1/PEA of 0.9, indicating an origin of PEA other than an orally ingested drug formulation. Consequently, the consideration of analyte abundance ratios (e.g. M1/PEA) is suggested as a means to identify the use of PEA by athletes, but further studies to support potential decisive criteria are warranted. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  15. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  16. Effects of incentives for naltrexone adherence on opiate abstinence in heroin-dependent adults

    PubMed Central

    Jarvis, Brantley P.; Holtyn, August F.; DeFulio, Anthony; Dunn, Kelly E.; Everly, Jeffrey J.; Leoutsakos, Jeannie-Marie S.; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Silverman, Kenneth

    2017-01-01

    Aim To test whether an incentive-based intervention that increased adherence to naltrexone also increased opiate abstinence. Design Post-hoc combined analysis of three earlier randomized controlled trials that individually showed that incentives for adherence to oral and to extended-release injection naltrexone dosing schedules increased naltrexone adherence but not opiate abstinence. Setting Outpatient therapeutic workplace in Baltimore, MD, USA. Participants 140 unemployed heroin-dependent adults participating from 2006–2010. Interventions Participants were hired in a model workplace for 26 weeks and randomized to a Contingency (n=72) or Prescription (n=68) group. Both groups were offered naltrexone. Contingency participants were required to take scheduled doses of naltrexone in order to work and earn wages. Prescription participants could earn wages independent of naltrexone adherence. Measures Thrice-weekly and monthly urine samples tested for opiates and cocaine and measures of naltrexone adherence (percentage of monthly urine samples positive for naltrexone or percentage of scheduled injections received). All analyses included prerandomization attendance, opiate use, and cocaine use as covariates. Additional analyses controlled for cocaine use and naltrexone adherence during the intervention. Findings Contingency participants had more opiate abstinence than Prescription participants (68.1% vs. 52.9% opiate-negative thrice-weekly urine samples, respectively; and 71.9% vs. 61.7% opiate-negative monthly urine samples, respectively) based on initial analyses (thrice-weekly samples, OR = 3.3, 95% CI = 1.7–6.5, p < .01; monthly samples, OR = 2.6, 95% CI = 1.0–7.1, p = .06) and on analyses that controlled for cocaine use (thrice-weekly samples, OR = 3.9, 95% CI = 3.3–4.5, p < .01; monthly samples, OR = 3.4, 95% CI = 1.1–11.1, p =.04), which was high and associated with opiate use. The difference in opiate abstinence rates between Contingency participants and Prescription participants was reduced when controlling for naltrexone adherence (monthly samples, OR = 1.1, 95% CI = 0.7–1.7, p = .84). Conclusions Incentives for naltrexone adherence increase opiate abstinence in heroin-dependent adults, an effect that appears to be due to increased naltrexone adherence produced by the incentives. PMID:27936293

  17. Black market products confiscated in Norway 2011-2014 compared to analytical findings in urine samples.

    PubMed

    Hullstein, Ingunn R; Malerod-Fjeld, Helle; Dehnes, Yvette; Hemmersbach, Peter

    2015-01-01

    Doping agents are widely and illicitly distributed through the Internet. Analysis of these preparations is useful in order to monitor the availability of prohibited substances on the market, and more importantly to predict which substances are expected to be found in urine samples collected from athletes and to aid clinical and forensic investigations. Based on a close collaboration with the Norwegian police and the Norwegian custom authorities, the Norwegian Doping Control Laboratory has performed analyses of confiscated material suspected of containing doping agents. The analyses were performed using gas chromatography (GC) and liquid chromatography (LC) combined with mass spectrometry (MS). The majority (67%) of the analyzed black market products contained anabolic- androgenic steroids (AAS) as expected, whereas peptide- and protein-based doping substances were identified in 28% of the preparations. The Norwegian Doping Control Laboratory receives samples collected from recreational and elite athletes in addition to samples collected in clinical and forensic investigations. The findings in the seized material reflected the findings in the urine samples analyzed regarding the anabolic steroids. Thus, analyzing material seized in Norway may give a good indication of doping agents available on the local market. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.

    PubMed

    Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A

    2018-02-01

    This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-hr urine samples for 50 adults in North Carolina

    EPA Science Inventory

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study ...

  20. Suitability of bovine bile compared to urine for detection of free, sulfate and glucuronate boldenone, androstadienedione, cortisol, cortisone, prednisolone, prednisone and dexamethasone by LC-MS/MS.

    PubMed

    Chiesa, Luca; Nobile, Maria; Panseri, Sara; Vigo, Daniele; Pavlovic, Radmila; Arioli, Francesco

    2015-12-01

    The administration of boldenone and androstadienedione to cattle is forbidden in the European Union, while prednisolone is permitted for therapeutic purposes. They are pseudoendogenous substances (endogenously produced under certain circumstances). The commonly used matrices in control analyses are urine or liver. With the aim of improving the residue controls, we previously validated a method for steroid analysis in bile. We now compare urine (a 'classic' matrix) to bile, both collected at the slaughterhouse, to understand whether the detection of steroids in the latter is easier. With the aim of having clearer results, we tested the presence of the synthetic corticosteroid dexamethasone. The results show that bile does not substantially improve the detection of boldenone, or its conjugates, prednisolone and prednisone. Dexamethasone, instead, was found in 10 out of 53 bovine bile samples, but only in one urine sample from the same animals. Bile could constitute a novel matrix for the analysis of residues in food-producing animals, and possibly not only of synthetic corticosteroids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less

  2. Hypoglycin A Content in Blood and Urine Discriminates Horses with Atypical Myopathy from Clinically Normal Horses Grazing on the Same Pasture

    PubMed Central

    Bochnia, M.; Ziegler, J.; Sander, J.; Uhlig, A.; Schaefer, S.; Vollstedt, S.; Glatter, M.; Abel, S.; Recknagel, S.; Schusser, G. F.; Wensch-Dorendorf, M.; Zeyner, A.

    2015-01-01

    Hypoglycin A (HGA) in seeds of Acer spp. is suspected to cause seasonal pasture myopathy in North America and equine atypical myopathy (AM) in Europe, fatal diseases in horses on pasture. In previous studies, this suspicion was substantiated by the correlation of seed HGA content with the concentrations of toxic metabolites in urine and serum (MCPA-conjugates) of affected horses. However, seed sampling was conducted after rather than during an outbreak of the disease. The aim of this study was to further confirm the causality between HGA occurrence and disease outbreak by seed sampling during an outbreak and the determination of i) HGA in seeds and of ii) HGA and MCPA-conjugates in urine and serum of diseased horses. Furthermore, cograzing healthy horses, which were present on AM affected pastures, were also investigated. AM-pastures in Germany were visited to identify seeds of Acer pseudoplatanus and serum (n = 8) as well as urine (n = 6) from a total of 16 diseased horses were analyzed for amino acid composition by LC-ESI-MS/MS, with a special focus on the content of HGA. Additionally, the content of its toxic metabolite was measured in its conjugated form in body fluids (UPLC-MS/MS). The seeds contained 1.7–319.8 μg HGA/g seed. The content of HGA in serum of affected horses ranged from 387.8–8493.8 μg/L (controls < 10 μg/L), and in urine from 143.8–926.4 μg/L (controls < 10 μg/L), respectively. Healthy cograzing horses on AM-pastures showed higher serum (108.8 ± 83.76 μg/L) and urine concentrations (26.9 ± 7.39 μg/L) compared to control horses, but lower concentrations compared to diseased horses. The range of MCPA-carnitine and creatinine concentrations found in diseased horses in serum and urine were 0.17–0.65 mmol/L (controls < 0.01), and 0.34–2.05 μmol/mmoL (controls < 0.001), respectively. MCPA-glycine levels in urine of cograzing horses were higher compared to controls. Thus, the causal link between HGA intoxication and disease outbreak could be further substantiated, and the early detection of HGA in cograzing horses, which are clinically normal, might be a promising step in prophylaxis. PMID:26378918

  3. Solid-phase microextraction and chiral HPLC analysis of ibuprofen in urine.

    PubMed

    de Oliveira, Anderson Rodrigo Moraes; Cesarino, Evandro José; Bonato, Pierina Sueli

    2005-04-25

    A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.

  4. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKES

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 49 field control samples (spikes). Measurements were made for up to 11 metals in samples of water, blood, and urine. Field controls were used to assess recovery of target analytes from a sample media during s...

  5. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES

    EPA Science Inventory

    The Metals in Spikes data set contains the analytical results of measurements of up to 4 metals in 71 control samples (spikes) from 47 households. Measurements were made in samples of indoor and outdoor air, blood, and urine. Controls were used to assess recovery of target anal...

  6. Mutagenic activity and metabolites in the urine of workers exposed to trinitrotoluene (TNT).

    PubMed Central

    Ahlborg, G; Einistö, P; Sorsa, M

    1988-01-01

    Urine samples taken after work and after a free weekend from 50 workers employed in various activities in a chemical plant manufacturing explosives were analysed. On the basis of hygienic surveys, the subjects were divided into three categories of exposure to trinitrotoluene (TNT). The urine analyses consisted of gas chromatographic identification of TNT and its two metabolites, 4-ADNT and 2-ADNT, and a determination of the mutagenic activity. Two frame shift detector strains of Salmonella typhimurium were used, TA 98 and TA 98 NR, the latter being deficient in endogenous nitroreductase activity. On the basis of previous results on TNT mutagenicity, no exogeneous metabolic system was used to test the urine concentrates. Both tester strains showed that the mean urinary mutagenic activity was higher in the after work samples than in post weekend samples from the same subjects, showing that bacterial nitroreductase activity was not significantly responsible for the mutagenicity, although the response was higher with strain TA 98 than with TA 98 NR. The interindividual variation in urine mutagenicity was high, however, and the difference between the two sampling times was statistically significant (p less than 0.05) only for the high exposed group (workers in trotyl foundry and sieve house). Correlation between urinary mutagenicity and concentration of TNT in urine was poor; correlation was significant only with the urinary concentration of 4-ADNT. The correlation between urinary TNT and both metabolites was good (p less than 0.001). These results suggest that analysis of 4-ADNT in urine would be a sufficient biological measure for controlling exposure to TNT. PMID:3378017

  7. Epidemiological investigation of the UGT2B17 polymorphism in doping control urine samples and its correlation to T/E ratios.

    PubMed

    Anielski, Patricia; Simmchen, Juliane; Wassill, Lars; Ganghofner, Dirk; Thieme, Detlef

    2011-10-01

    The deletion polymorphism of the enzyme UGT2B17 is known to correlate with the level of the testosterone to epitestosterone (T/E) ratio in urine specimen. Due to the importance of the T/E ratio to detect testosterone abuse in doping analysis, a PCR-ELISA system (Genotype® UGT test, AmplexDiagnostics) was established to identify the UGT2B17 phenotype in urine samples. Epidemiological investigations in a set of 674 routine doping controls (in- and out-of-competition) resulted in 22.8% homozygote gene-deleted and 74.5% UGT2B17-positive athletes. The validated test system has shown to be robust and sensitive: in only 18 cases (2.7%) isolation of cell material from urine failed. Following hydrolysis of glucuronidated conjugates, steroids were analyzed as bis-TMS derivatives by gas chromatography-mass spectrometry (GC-MS), for example, testosterone (T) and epitestosterone (E). Additionally, isotope ration mass spectrometry (IRMS) analysis and luteinizing hormone (LH) measurement were applied. Mean T/E ratios significantly correlated with the UGT2B17 phenotype (del: T/E 0.9; pos: 1.7), however the values did not differ as distinctive as reported in previous studies. Additionally, the T/E ratios in the gene-deleted group did not show a normal curve of distribution (median of T/E 0.5). Obviously, beside the UGT2B17 deletion further influences have to be taken into account, for example, polymorphisms or induction of other metabolizing enzymes. Our results indicate that the UGT2B17 polymorphism might be insufficient when utilized solely as a crucial parameter for individual interpretation of T/E in urine. Nevertheless, the detection of the UGT2B17-gene deletion in urine samples would provide additional information important for gathering evidence in analysis of steroids in doping control. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Screening for the synthetic cannabinoid JWH-018 and its major metabolites in human doping controls.

    PubMed

    Möller, Ines; Wintermeyer, Annette; Bender, Katja; Jübner, Martin; Thomas, Andreas; Krug, Oliver; Schänzer, Wilhelm; Thevis, Mario

    2011-09-01

    Referred to as 'spice', several new drugs, advertised as herbal blends, have appeared on the market in the last few years, in which the synthetic cannabinoids JWH-018 and a C(8) homologue of CP 47,497 were identified as major active ingredients. Due to their reported cannabis-like effects, many European countries have banned these substances. The World Anti-Doping Agency has also explicitly prohibited synthetic cannabinoids in elite sport in-competition. Since urine specimens have been the preferred doping control samples, the elucidation of the metabolic pathways of these substances is of particular importance to implement them in sports drug testing programmes. In a recent report, an in vitro phase-I metabolism study of JWH-018 was presented yielding mainly hydroxylated and N-dealkylated metabolites. Due to these findings, a urine sample of a healthy man declaring to have smoked a 'spice' product was screened for potential phase-I and -II metabolites by high-resolution/high-accuracy mass spectrometry in the present report. The majority of the phase-I metabolites observed in earlier in vitro studies of JWH-018 were detected in this urine specimen and furthermore most of their respective monoglucuronides. As no intact JWH-018 was detectable, the monohydroxylated metabolite being the most abundant one was chosen as a target analyte for sports drug testing purposes; a detection method was subsequently developed and validated in accordance to conventional screening protocols based on enzymatic hydrolysis, liquid-liquid extraction, and liquid chromatography/electrospray tandem mass spectrometry analysis. The method was applied to approximately 7500 urine doping control samples yielding two JWH-018 findings and demonstrated its capability for a sensitive and selective identification of JWH-018 and its metabolites in human urine. Copyright © 2010 John Wiley & Sons, Ltd.

  9. Doping control analysis of 46 polar drugs in horse plasma and urine using a 'dilute-and-shoot' ultra high performance liquid chromatography-high resolution mass spectrometry approach.

    PubMed

    Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M

    2016-06-17

    The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies.

    PubMed

    Gagnebin, Yoric; Tonoli, David; Lescuyer, Pierre; Ponte, Belen; de Seigneux, Sophie; Martin, Pierre-Yves; Schappler, Julie; Boccard, Julien; Rudaz, Serge

    2017-02-22

    Among the various biological matrices used in metabolomics, urine is a biofluid of major interest because of its non-invasive collection and its availability in large quantities. However, significant sources of variability in urine metabolomics based on UHPLC-MS are related to the analytical drift and variation of the sample concentration, thus requiring normalization. A sequential normalization strategy was developed to remove these detrimental effects, including: (i) pre-acquisition sample normalization by individual dilution factors to narrow the concentration range and to standardize the analytical conditions, (ii) post-acquisition data normalization by quality control-based robust LOESS signal correction (QC-RLSC) to correct for potential analytical drift, and (iii) post-acquisition data normalization by MS total useful signal (MSTUS) or probabilistic quotient normalization (PQN) to prevent the impact of concentration variability. This generic strategy was performed with urine samples from healthy individuals and was further implemented in the context of a clinical study to detect alterations in urine metabolomic profiles due to kidney failure. In the case of kidney failure, the relation between creatinine/osmolality and the sample concentration is modified, and relying only on these measurements for normalization could be highly detrimental. The sequential normalization strategy was demonstrated to significantly improve patient stratification by decreasing the unwanted variability and thus enhancing data quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. UPT scenarios: Implications for system reliability

    NASA Technical Reports Server (NTRS)

    Walsh, Daniel W.

    1992-01-01

    The objective of this project was to examine the corrosion resistance of 316L stainless steel in several urine pre-treat solutions. Four solutions were examined: untreated urine (control); urine pretreated with oxone (potassium peroxymonosulfate sulfate); urine pretreated with sodium hypochlorite (NaOCl); and urine pretreated with ozone (O3). In accordance with current procedures, all solutions but the control were acidified to a pH of 2.5 using sulfuric acid--this suppresses the generation of ammonia in the solutions and is intended to limit microbial growth. Welded and unwelded coupons were exposed to each solution. In addition, Titanium coupons (welded and unwelded) were exposed to biologically active environmental control and life support system (ECLSS) water. Microbial attachment and biofilm growth were monitored. Ozone was examined as a biocide/oxidizer/corrosion preventative (simultaneous addition) and as a remediation method (added one week after exposure). In an unrelated effort, HP 9-4-30 coupons were exposed to biologically active solutions. Corrosion rates for welded and unwelded samples were determined--results were correlated to the ongoing HP 9-4-30 weldment stress corrosion study.

  12. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  13. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  14. Monitoring Body Water Balance in Pregnant and Nursing Women: The Validity of Urine Color.

    PubMed

    McKenzie, Amy L; Armstrong, Lawrence E

    2017-01-01

    Urine osmolality (UOSM) reflects the renal regulation of excess fluid or deficit fluid, and therefore, serves as a marker of hydration status. Little is known about monitoring hydration in pregnant and lactating women despite significant physiological challenges to body water balance during that time. Therefore, we designed a study to assess if urine color (UCOL), an inexpensive and practical method, was a valid means of assessing urine concentration. Twenty-four hour UCOL was significantly correlated with 24 h UOSM in all women: pregnant, lactating, and control (r = 0.61-0.84, all p < 0.001). Utilizing a receiver operating characteristic statistical analysis, we found that 24 h and single sample UCOL had excellent diagnostic accuracy for identifying UOSM ≥500 mOsm·kg-1 in all women (area under the curve = 0.68-0.95, p < 0.001-0.46), and the UCOL that reflected this cut off was ≥4 on the UCOL chart. Therefore, UCOL is a valid marker of urine concentration and ultimately hydration status in pregnant, lactating, and non-pregnant, non-lactating women. For pregnant, lactating, and control women, the UCOL chart is a valid tool that can be used to monitor urine concentration in a single sample or over the course of the day via a 24 h sample. Key Message: Women who present with a UCOL of 4 or more likely have a UOSM ≥500 mOsm·kg-1. Given the positive health benefits associated with UOSM <500 mOsm·kg-1, women should aim for a 1, 2, or 3 on the UCOL chart. If a UCOL of ≥4 is observed, women should consider increasing fluid consumption to improve hydration status. © 2017 The Author(s) Published by S. Karger AG, Basel.

  15. The ultimate veal calf reference experiment: hormone residue analysis data obtained by gas and liquid chromatography tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Lasaroms, Johan J P; Essers, Martien L; Sanders, Marieke B; Heskamp, Henri H; Bovee, Toine F H; van Rhijn, J Hans; Groot, Maria J

    2007-03-14

    A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.

  16. A method for the simultaneous quantification of eight metabolites of synthetic pyrethroids in urine of the general population using gas chromatography-tandem mass spectrometry.

    PubMed

    Schettgen, Thomas; Dewes, Petra; Kraus, Thomas

    2016-08-01

    Synthetic pyrethroids are highly effective, widespread insecticides applied worldwide for different purposes. Among the possible sources of exposure for the general population, pyrethroid residues in food and their prominent use for the conservation of wool carpets or in indoor pest control might play a major role. On the basis of previous works, we have developed and validated a highly sensitive and specific GC/MS/MS-method to simultaneously quantify the metabolites of the most common synthetic pyrethroids in urine, namely cis- and trans-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylic acid (DCCA), cis-(2,2-dibromovinyl)-2,2-dimethylcyclopropanecarboxylic acid (DBCA), 4-fluoro-3-phenoxybenzoic acid (F-PBA), 3-phenoxybenzoic acid (3-PBA) as well as the metabolites cis-3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethyl-cyclopropanecarboxylic acid (ClF3CA, λ-cyhalothrin/bifenthrin), 4-chloro-α-isopropylbenzene acetic acid (CPBA, esfenvalerate), and 2-methyl-3-phenylbenzoic acid (MPB, bifenthrin). After acidic hydrolysis to cleave conjugates in urine, the analytes are subjected to a pH-controlled extraction into n-hexane. After concentration, the analytes are derivatised using MTBSTFA and finally quantified by GC/MS/MS in EI-mode using d6-trans-DCCA and (13)C6-3-PBA as internal standards. The limit of quantification for these metabolites was 0.01 μg/L urine. Precision within and between series was determined to range between 1.6 and 10.7 % using a native quality control sample as well as a urine sample spiked with 0.3 μg/L of the analytes. To investigate possible background excretions, we analysed spot urine samples of 38 persons of the general population in a pilot study. cis- and trans-DCCA as well as 3-PBA could be quantified in every urine sample investigated, while MPB and F-PBA could only be detected in two samples. The median levels for excretion of cis-DCCA, trans-DCCA, 3-PBA, ClF3CA, DBCA, CPBA, F-PBA and MPA were 0.08, 0.17, 0.22, 0.04, 0.04, <0.01, <0.01 and < 0.01 μg/L urine, respectively. The excretion of metabolites revealed excellent correlations between cyclopropane carboxylic acids and 3-PBA. Our method is highly suitable for human biomonitoring of exposures to synthetic pyrethroids in environmental medicine. Remarkable are the high detection rates for the metabolites ClF3CA (90 %) and CPBA (40 %), proving that their parent pyrethroids have entered the market in Germany.

  17. Validation of a multi-analyte HPLC-DAD method for determination of uric acid, creatinine, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid and 2-methylhippuric acid in human urine.

    PubMed

    Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K

    2015-08-15

    During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  19. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  20. Detox agents do not affect the pharmacokinetics of methamphetamine in the rat.

    PubMed

    Lee, Sang Kyu; Kim, Yoon; Suh, Sungill; Suh, Yong Jun; In, Moon Kyo; Kim, Dong-Hyun; Jin, Changbae; Yoo, Hye Hyun

    2009-04-15

    Recently, 'detox' agents have been popularly used as forms of diets or nutritional supplements. Especially, several cases have been reported that these detox agents have been used to mask drug tests among drug abusers. In the present study, capsule and drink types of detox agents were evaluated for their ability to alter the elimination of methamphetamine (MA) in rats. For this study, MA and its major metabolite, amphetamine (AP) in urine samples were determined using LC-tandem mass spectrometry after administration of the detox agents to MA-treated rats. As a result, significant differences were not shown between control and detox-dosed groups in the amounts of MA and AP excreted into urine as well as the volume of excreted urine. This result suggests that the detox agents tested may not affect the metabolism or elimination of MA and further might have minimal effect on narcotics detection in the urine samples of drug abusers.

  1. Chemical composition of rainbow trout urine following acute hypoxic stress

    USGS Publications Warehouse

    Hunn, Joseph B.

    1969-01-01

    Rainbow trout (Salmo gairdnerii) were anesthetized with MS-222, catheterized, and introduced into urine collecting chambers. Twenty-four hours after introduction, a 4-hour accumulation of urine was collected to serve as the control. Water flow to the chambers was then discontinued for 30 minutes during which the oxygen content of the water exiting in the chamber dropped from 4.9 to 2.8 mg/l. Following this hypoxic stress fresh water was restored and accumulated urine samples were taken for analysis at 1, 4, and 20 hours post-hypoxic stress. Rainbow trout excrete abnormally high concentrations of Na, K, Mg, Cl, and inorganic PO4 following hypoxia.

  2. The method of urine sampling is not a valid predictor for vesicoureteral reflux in children after febrile urinary tract infections.

    PubMed

    Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef

    2017-10-01

    The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  3. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-h urine samples for 50 adults in North Carolina.

    PubMed

    Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S

    2016-01-01

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.

  4. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  5. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES

    EPA Science Inventory

    The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 38 control samples (spikes) from 18 households. Measurements were made in spiked samples of dust, food, beverages, blood, urine, and dermal wipe residue. Spiked samples we...

  7. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN SPIKE SAMPLES

    EPA Science Inventory

    The Pesticide Metabolites in Spike Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 control samples (spikes) from 3 households. Measurements were made in spiked samples of urine. Spiked samples were used to assess recovery o...

  8. Determination of designer doping agent--2-ethylamino-1-phenylbutane--in dietary supplements and excretion study following single oral supplement dose.

    PubMed

    Wójtowicz, Marzena; Jarek, Anna; Chajewska, Katarzyna; Turek-Lepa, Ewa; Kwiatkowska, Dorota

    2015-11-10

    The quantitative analysis of a new designer doping agent, 2-ethylamino-1-phenylbutane (EAPB) and its metabolite, 2-amino-1-phenylbutane (APB) in urine samples, and the determination of EAPB in dietary supplement samples, have been presented. The main purpose of the present study was to develop simple and reliable gas chromatography-mass spectrometry method (GC-MS) for excretion study following a single oral administration of dietary supplements containing EAPB. Three analytical methods for the determination of EAPB in urine and supplement samples, and APB in urine samples using the GC-MS system, have been validated. The method of the determination of EAPB in supplement samples was applied to analyze seventeen dietary supplements, CRAZE and DETONATE. Two other methods were used to determine the urinary excretion profile of EAPB and APB in the case of three healthy volunteers and, on further investigation, it was applied to the anti-doping control in sport. Quantification was obtained on the basis of the ions at m/z 86, 58 and 169, monitored for EAPB, APB and diphenylamine (used as an internal standard), respectively. The limits of detection and quantification were 2.4 and 7.3μg/g for EAPB in the case of supplement analysis, 2.9 and 8.8ng/mL for EAPB in the case of urine analysis, and 3.2 and 9.7ng/mL for APB. The other validation parameters as linearity, precision and trueness have been also investigated with the acceptable results. The extraction yield of all presented methods was above 69%. EAPB was detected in fourteen analyzed supplements (not included EAPB in their labels) and its content varied between 1.8 and 16.1mg/g. Following oral administration of three supplements with EAPB to one male and two female volunteers, the parent compound of EAPB and its metabolite were monitored and the excretion parameters as the maximum concentration of the analyte in urine (2.2-4.2μg/mL for EAPB; 1.1-5.1μg/mL for APB) and the time for the maximum height of the excretion peak (2-8h and 22h in one case for EAPB; 20-22h and 4h in one case for APB) have been indicated. EAPB and APB were detected at the level above 50ng/mL (50% of the minimum required performance level for stimulants in the anti-doping control in-competition in sport) in the urine up to 46-106h and 58-120h, respectively. Additionally, the result of the anti-doping control during swimming competition of one athlete, whose urine sample was analyzed for stimulants and narcotics, has been presented. The qualitative and quantitative analyses of new designer agents in urine samples and the excretion studies of these substances are of a great importance in the anti-doping control in sport. Moreover, the presentation of detection examples of these agents in supplements that haven't got included an information about them in the labeling, make athletes (and other supplement customers) more and more aware of the risk of the supplement use and possible health and doping consequences. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Detection of anabolic androgenic steroid abuse in doping control using mammalian reporter gene bioassays.

    PubMed

    Houtman, Corine J; Sterk, Saskia S; van de Heijning, Monique P M; Brouwer, Abraham; Stephany, Rainer W; van der Burg, Bart; Sonneveld, Edwin

    2009-04-01

    Anabolic androgenic steroids (AAS) are a class of steroid hormones related to the male hormone testosterone. They are frequently detected as drugs in sport doping control. Being similar to or derived from natural male hormones, AAS share the activation of the androgen receptor (AR) as common mechanism of action. The mammalian androgen responsive reporter gene assay (AR CALUX bioassay), measuring compounds interacting with the AR can be used for the analysis of AAS without the necessity of knowing their chemical structure beforehand, whereas current chemical-analytical approaches may have difficulty in detecting compounds with unknown structures, such as designer steroids. This study demonstrated that AAS prohibited in sports and potential designer AAS can be detected with this AR reporter gene assay, but that also additional steroid activities of AAS could be found using additional mammalian bioassays for other types of steroid hormones. Mixtures of AAS were found to behave additively in the AR reporter gene assay showing that it is possible to use this method for complex mixtures as are found in doping control samples, including mixtures that are a result of multi drug use. To test if mammalian reporter gene assays could be used for the detection of AAS in urine samples, background steroidal activities were measured. AAS-spiked urine samples, mimicking doping positive samples, showed significantly higher androgenic activities than unspiked samples. GC-MS analysis of endogenous androgens and AR reporter gene assay analysis of urine samples showed how a combined chemical-analytical and bioassay approach can be used to identify samples containing AAS. The results indicate that the AR reporter gene assay, in addition to chemical-analytical methods, can be a valuable tool for the analysis of AAS for doping control purposes.

  10. Urine sample (image)

    MedlinePlus

    A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...

  11. Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.

    PubMed

    Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S

    2013-01-01

    To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.

  12. Development of isotope labeling liquid chromatography mass spectrometry for mouse urine metabolomics: quantitative metabolomic study of transgenic mice related to Alzheimer's disease.

    PubMed

    Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang

    2014-10-03

    Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous metabolomics studies in human cerebrospinal fluid or blood samples. This work illustrates the utility of this isotope labeling LC-MS method for biomarker discovery using mouse urine metabolomics.

  13. Detection of Ciprofloxacin in Urine through Sensitized Lanthanide Luminescence

    PubMed Central

    Singha, Subhankar; Ahn, Kyo Han

    2016-01-01

    Ciprofloxacin, a fluoroquinolone antibiotic, is widely used for the treatment of bacterial infection in humans due to its broad antibacterial spectrum. An excessive use or overdose of ciprofloxacin on the other hand can cause several adverse effects not only to humans but also to microorganisms. Unabsorbed ciprofloxacin in the body is mostly excreted through urine and finally goes to the environment, providing a drug resistance pressure on bacteria. Hence a simple and efficient detection method of ciprofloxacin is necessary, which, for example, can be used to analyze ciprofloxacin content in urine. Although ciprofloxacin itself shows inherent fluorescence, direct fluorescent detection of ciprofloxacin in raw urine sample is difficult due to autofluorescence of urine by other components. Herein we report that a Tb(III) complex of DO3A (1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid) can be efficiently sensitized by ciprofloxacin to emit luminescence separately from the urine autofluorescence wavelength region. Tb-DO3A shows excellent sensitivity with a detection limit of three parts per billion in aqueous buffer solution. Further, Tb-DO3A is used to detect ciprofloxacin with high sensitivity and selectivity in a raw urine sample without any purification or separation procedures in the concentrations ranging from 1 µg·mL−1 to 50 µg·mL−1. The direct measurement of ciprofloxacin excreted in urine may be used to control overdose of the drug. PMID:27929396

  14. Development and validation of an ultra-performance liquid chromatography quadrupole time of flight mass spectrometry method for rapid quantification of free amino acids in human urine.

    PubMed

    Joyce, Richard; Kuziene, Viktorija; Zou, Xin; Wang, Xueting; Pullen, Frank; Loo, Ruey Leng

    2016-01-01

    An ultra-performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-qTOF-MS) method using hydrophilic interaction liquid chromatography was developed and validated for simultaneous quantification of 18 free amino acids in urine with a total acquisition time including the column re-equilibration of less than 18 min per sample. This method involves simple sample preparation steps which consisted of 15 times dilution with acetonitrile to give a final composition of 25 % aqueous and 75 % acetonitrile without the need of any derivatization. The dynamic range for our calibration curve is approximately two orders of magnitude (120-fold from the lowest calibration curve point) with good linearity (r (2) ≥ 0.995 for all amino acids). Good separation of all amino acids as well as good intra- and inter-day accuracy (<15 %) and precision (<15 %) were observed using three quality control samples at a concentration of low, medium and high range of the calibration curve. The limits of detection (LOD) and lower limit of quantification of our method were ranging from approximately 1-300 nM and 0.01-0.5 µM, respectively. The stability of amino acids in the prepared urine samples was found to be stable for 72 h at 4 °C, after one freeze thaw cycle and for up to 4 weeks at -80 °C. We have applied this method to quantify the content of 18 free amino acids in 646 urine samples from a dietary intervention study. We were able to quantify all 18 free amino acids in these urine samples, if they were present at a level above the LOD. We found our method to be reproducible (accuracy and precision were typically <10 % for QCL, QCM and QCH) and the relatively high sample throughput nature of this method potentially makes it a suitable alternative for the analysis of urine samples in clinical setting.

  15. A random urine test can identify patients at risk of mesalamine non-adherence: a prospective study.

    PubMed

    Gifford, Anne E; Berg, Anders H; Lahiff, Conor; Cheifetz, Adam S; Horowitz, Gary; Moss, Alan C

    2013-02-01

    Mesalamine non-adherence is common among patients with ulcerative colitis (UC), and can be difficult to identify in practice. We sought to determine whether a random urine test for salicylates could be used as a marker of 5-aminosalicylic acid (5-ASA) ingestion and identify patients at risk of non-adherence. Our aim is to determine whether measurement of salicylates in a random urine sample correlates with 5-ASA levels, and predicts an individual's risk of mesalamine non-adherence. Prospective observational study. Urinary salicylates (by colorimetry) and 5-ASA (by liquid chromatography and tandem-mass spectrometry) were measured in a random urine sample at baseline in patients and controls. Mesalamine adherence was quantified by patient self-reports at enrollment and pharmacy refills of mesalamine over 6 months. A total of 93 patients with UC taking mesalamine maintenance therapy were prospectively enrolled from the clinic. Random urine salicylate levels (by colorimetry) were highly correlated with urine 5-ASA metabolite levels (by mass spectrometry; R2=0.9). A random urine salicylate level above 15 mg/dl distinguished patients who had recently taken mesalamine from controls (area under the curve value 0.9, sensitivity 95%, specificity 77%). A significant proportion of patients (27%) who self-identified as "high adherers" by an adherence questionnaire (Morisky Medication Adherence Scale-8) had random levels of urine salicylate below this threshold. These patients were at higher risk of objectively measured non-adherence to mesalamine over the subsequent 6 months (RR: 2.7, 95% CI: 1.1-7.0). A random urine salicylate level measured in the clinic can identify patients who have not recently taken mesalamine, and who are at higher risk of longitudinal non-adherence. This test could be used to screen patients who may warrant interventions to improve adherence and prevent disease relapse.

  16. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  17. Construction and Evaluation of Internal Control DNA for PCR Amplification of Chlamydia trachomatis DNA from Urine Samples

    PubMed Central

    Betsou, Fotini; Beaumont, Katy; Sueur, Jean Marie; Orfila, Jeanne

    2003-01-01

    An internal control DNA (ICD) with the same primer binding sequences as the target Chlamydia trachomatis DNA was constructed and evaluated in a PCR assay with immunoenzymatic detection. One hundred urine specimens were tested, and 23 were found to contain inhibitors of the PCR, if not subjected to DNA extraction prior to amplification. Coamplification and detection of the ICD appeared to be a useful method for estimating the effects of inhibitors on C. trachomatis DNA amplification. PMID:12624066

  18. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    PubMed

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  19. Detection of Bacteriuria by Canine Olfaction

    PubMed Central

    Maurer, Maureen; McCulloch, Michael; Willey, Angel M.; Hirsch, Wendi; Dewey, Danielle

    2016-01-01

    Background. Urinary tract infections (UTIs) are a significant medical problem , particularly for patients with neurological conditions and the elderly. Detection is often difficult in these patients, resulting in delayed diagnoses and more serious infections such as pyelonephritis and life-threatening sepsis. Many patients have a higher risk of UTIs because of impaired bladder function, catheterization, and lack of symptoms. Urinary tract infections are the most common nosocomial infection; however, better strategies are needed to improve early detection of the disease. Methods. In this double-blinded, case-control, validation study, we obtained fresh urine samples daily in a consecutive case series over a period of 16 weeks. Dogs were trained to distinguish urine samples that were culture-positive for bacteriuria from those of culture-negative controls, using reward-based clicker and treat methods. Results. Samples were obtained from 687 individuals (from 3 months to 92 years of age; 86% female and 14% male; 34% culture-positive and 66% culture-negative controls). Dogs detected urine samples positive for 100 000 colony-forming units/mL Escherichia coli (N = 250 trials; sensitivity 99.6%, specificity 91.5%). Dilution of E coli urine with distilled water did not affect accuracy at 1% (sensitivity 100%, specificity 91.1%) or 0.1% (sensitivity 100%, specificity 93.6%) concentration. Diagnostic accuracy was similar to Enterococcus (n = 50; sensitivity 100%, specificity 93.9%), Klebsiella (n = 50; sensitivity 100%, specificity 95.1%), and Staphylococcus aureus (n = 50; sensitivity 100%, specificity 96.3%). All dogs performed with similarly high accuracy: overall sensitivity was at or near 100%, and specificity was above 90%. Conclusions. Canine scent detection is an accurate and feasible method for detection of bacteriuria. PMID:27186578

  20. Stability of cannabinoids in urine in three storage temperatures.

    PubMed

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  1. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  2. Cancer sniffer dogs: how can we translate this peculiarity in laboratory medicine? Results of a pilot study on gastrointestinal cancers.

    PubMed

    Panebianco, Concetta; Kelman, Edgar; Vene, Kristel; Gioffreda, Domenica; Tavano, Francesca; Vilu, Raivo; Terracciano, Fulvia; Pata, Illar; Adamberg, Kaarel; Andriulli, Angelo; Pazienza, Valerio

    2017-11-27

    Identification of cancer biomarkers to allow early diagnosis is an urgent need for many types of tumors, whose prognosis strongly depends on the stage of the disease. Canine olfactory testing for detecting cancer is an emerging field of investigation. As an alternative, here we propose to use GC-Olfactometry (GC/O), which enables the speeding up of targeted biomarker identification and analysis. A pilot study was conducted in order to determine odor-active compounds in urine that discriminate patients with gastrointestinal cancers from control samples (healthy people). Headspace solid phase microextraction (HS-SPME)-GC/MS and GC-olfactometry (GC/O) analysis were performed on urine samples obtained from gastrointestinal cancer patients and healthy controls. In total, 91 key odor-active compounds were found in the urine samples. Although no odor-active biomarkers present were found in cancer carrier's urine, significant differences were discovered in the odor activities of 11 compounds in the urine of healthy and diseased people. Seven of above mentioned compounds were identified: thiophene, 2-methoxythiophene, dimethyl disulphide, 3-methyl-2-pentanone, 4-(or 5-)methyl-3-hexanone, 4-ethyl guaiacol and phenylacetic acid. The other four compounds remained unknown. GC/O has a big potential to identify compounds not detectable using untargeted GC/MS approach. This paves the way for further research aimed at improving and validating the performance of this technique so that the identified cancer-associated compounds may be introduced as biomarkers in clinical practice to support early cancer diagnosis.

  3. Clenbuterol storage stability in the bovine urine and liver samples used for European official control in the azores islands (portugal).

    PubMed

    Pinheiro, Isabel; Jesuino, Bruno; Barbosa, Jorge; Ferreira, Humberto; Ramos, Fernando; Matos, José; da Silveira, Maria Irene Noronha

    2009-02-11

    Clenbuterol is a well-known growth promoter, illegally used in farm animals, especially in cattle. Samples collected for the screening of beta(2)-agonist residues in Portuguese Azores Islands must travel through all the nine islands until they reach Azores Central Laboratory. If any suspicious sample is detected, it must be further transported to the National Reference Laboratory in Lisbon for confirmation. As a consequence of these circumstances, samples are submitted to different transport and storage times, as well as different temperature conditions and in some cases successive freezing and thawing cycles. As clenbuterol is the most detected beta(2)-agonist growth promoter in the Portuguese Residue Monitoring Plan, studies were conducted on the stability of this compound in incurred samples (bovine liver and urine) at +4, -20 and -60 degrees C over time. Samples kept at -20 degrees C were also analyzed over time after successive freezing and thawing cycles. The analyses of clenbuterol over time were performed by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). Clenbuterol in incurred urine and liver samples was significantly stable up to 20 weeks at -20 and -60 degrees C and after, at least, six consecutive freezings and thawings. At +4 degrees C, clenbuterol remained stable, at least until 12 weeks in urine and up to 20 weeks in liver.

  4. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  5. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS AND VOCS IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It provide...

  6. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOCS IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOC IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...

  8. Assessment of potential damage to DNA in urine of coke oven workers: an assay of unscheduled DNA synthesis.

    PubMed Central

    Roos, F; Renier, A; Ettlinger, J; Iwatsubo, Y; Letourneux, M; Haguenoer, J M; Jaurand, M C; Pairon, J C

    1997-01-01

    OBJECTIVES: A study was conducted in coke oven workers to evaluate the biological consequences of the exposure of these workers, particularly production of potential genotoxic factors. METHODS: 60 coke oven workers and 40 controls were recruited in the same iron and steel works. Exposure to polycyclic aromatic hydrocarbons (PAHs) was assessed by job and measurement of 1-hydroxypyrene (1OHP) in urine samples. An unscheduled DNA synthesis assay was performed on rat pleural mesothelial cells used as a test system to evaluate the effect of the workers' filtered urine on the DNA repair capacity of rat cells to determine whether DNA damaging agents are present in the urine of these workers. RESULTS: Urinary concentrations of 1OHP ranged from 0.06 to 24.2 (mean (SD) 2.1 (3.6)) mumol/mol creatinine in exposed coke oven workers, and from 0.01 to 0.9 in controls (0.12 (0.15)). These high concentrations in coke oven workers reflected recent exposure to PAHs and were in agreement with the assessment of exposure by job. No significant difference was found between coke oven workers and controls in the DNA repair level of rat cells treated with urine samples. However, the rat cell repair capacity decreased with increasing 1OHP concentrations in the exposed population (r = -0.28, P < 0.05). CONCLUSIONS: As high concentrations of 1OHP were found in the urine of some workers, a more stringent control of exposures to PAHs in the workplace is required. Exposure to PAHs was not associated with a clear cut modification of the urinary excretion of DNA damaging factors in this test, as shown by the absence of increased unscheduled DNA synthesis in rat cells. However, impairment of some repair mechanisms by urinary constituents is suspected. PMID:9470892

  9. Adulteration of urine by "Urine Luck".

    PubMed

    Wu, A H; Bristol, B; Sexton, K; Cassella-McLane, G; Holtman, V; Hill, D W

    1999-07-01

    In vitro adulterants are used to invalidate assays for urine drugs of abuse. The present study examined the effect of pyridinium chlorochromate (PCC) found in the product "Urine Luck". PCC was prepared and added to positive urine controls at concentrations of 0, 10, 50, and 100 g/L. The controls were assayed for methamphetamine, benzoylecgonine (BE), codeine and morphine, tetrahydrocannabinol (THC), and phencyclidine (PCP) with the Emit II (Syva) and Abuscreen Online (Roche) immunoassays, and by gas chromatography/mass spectrometry (GC/MS). Two tests were also developed to detect PCC in urine: a spot test to detect chromate ions using 10 g/L 1,5-diphenylcarbazide as the indicator, and a GC/MS assay for pyridine. We tested 150 samples submitted for routine urinalysis, compliance, and workplace drug testing for PCC, using these assays. Response rates decreased at 100 g/L PCC for all Emit II drug assays and for the Abuscreen morphine and THC assays. In contrast, the Abuscreen amphetamine assay produced apparently higher results, and no effect was seen on the results for BE or PCP. The PCC did not affect the GC/MS recovery of methamphetamine, BE, PCP, or their deuterated internal standards, but decreased GC/MS recovery of the opiates at both intermediate (50 g/L) and high (100 g/L) PCC concentrations and apparent concentrations of THC and THC-d3 at all PCC concentrations. Two of 50 samples submitted for workplace drug testing under chain-of-custody conditions were positive for PCC, whereas none of the remaining 100 specimens submitted for routine urinalysis or compliance drug testing were positive. PCC is an effective adulterant for urine drug testing of THC and opiates. Identification of PCC use can be accomplished with use of a spot test for the oxidant.

  10. Reliable determination of new lipid peroxidation compounds as potential early Alzheimer Disease biomarkers.

    PubMed

    García-Blanco, Ana; Peña-Bautista, Carmen; Oger, Camille; Vigor, Claire; Galano, Jean-Marie; Durand, Thierry; Martín-Ibáñez, Nuria; Baquero, Miguel; Vento, Máximo; Cháfer-Pericás, Consuelo

    2018-07-01

    Lipid peroxidation plays an important role in Alzheimer Disease, so corresponding metabolites found in urine samples could be potential biomarkers. The aim of this work is to develop a reliable ultra-performance liquid chromatography-tandem mass spectrometry analytical method to determine a new set of lipid peroxidation compounds in urine samples. Excellent sensitivity was achieved with limits of detection between 0.08 and 17 nmol L -1 , which renders this method suitable to monitor analytes concentrations in real samples. The method's precision was satisfactory with coefficients of variation around 5-17% (intra-day) and 8-19% (inter-day). The accuracy of the method was assessed by analysis of spiked urine samples obtaining recoveries between 70% and 120% for most of the analytes. The utility of the described method was tested by analyzing urine samples from patients early diagnosed with mild cognitive impairment or mild dementia Alzheimer Disease following the clinical standard criteria. As preliminary results, some analytes (17(RS)-10-epi-SC-Δ 15 -11-dihomo-IsoF, PGE 2 ) and total parameters (Neuroprostanes, Isoprostanes, Isofurans) show differences between the control and the clinical groups. So, these analytes could be potential early Alzheimer Disease biomarkers assessing the patients' pro-oxidant condition. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Pharmacokinetics, excretion of 8-cetylberberine and its main metabolites in rat urine.

    PubMed

    Hu, Yuli; Fan, Shoujun; Liao, Xiaobing; Chen, Chao; Su, Liang; Li, Xuegang

    2017-01-05

    Berberine (BBR) is a bioactive plant ingredient derived from the roots and bark of Berberis aristata and Coptis chinensis and has a wide variety of pharmacological effects. 8-cetylberberine (8-BBR-C16) is the berberine (BBR) derivative reconstructed from adding octadecyl at C-8 of BBR to enhance its activity. This study presents a reliable method for the determination of BBR and 8-BBR-C16 in rat plasma, urine and feces. BBR and 8-BBR-C16 were determined by HPLC-UV after liquid-liquid extraction for plasma samples, and solid-phase extraction for urinary and fecal samples. The method was linear over the concentration range of 10-300 ng·ml -1 for the plasma samples, 25-2000 ng·ml -1 for the urinary samples, and 100-2000 ng·g -1 for the fecal samples. Furthermore, a metabolic investigation on urine was performed by LC/MS/MS analysis to identify the structures of 8-BBR-C16 metabolites by full scan and product ion scan. Adult Sprague-Dawley rats were divided into two groups. In the control group, rats received 80 mg·kg -1 BBR, and in the drug-treated group, rats received 80 mg·kg -1 8-BBR-C16. The results indicate that there were significant differences in the pharmacokinetic parameters and in the accumulated excretion levels between the control group and the drug-treated group. The C max and AUC 0-t of 8-BBR-C16 were 2.8 and 12.9 times higher than those of BBR, and the relative bioavailability of BBR to 8-BBR-C16 was 7.7%. The total excretion amount through the urine and feces of 8-BBR-C16 was 76.9%, but that of BBR was only 20.5%. Additionally, 8-BBR-C16 was metabolized in rat urine with phase I demethylation and phase II glucuronidation or sulfation. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Biomonitoring of exposure to N-methyl-2-pyrrolidone in workers of the automobile industry.

    PubMed

    Meier, Swetlana; Schindler, Birgit K; Koslitz, Stephan; Koch, Holger M; Weiss, Tobias; Käfferlein, Heiko U; Brüning, Thomas

    2013-07-01

    N-methyl-2-pyrrolidone (NMP) is an important organic solvent for varnishes in industry. NMP has been previously shown to be a developmental toxicant in rodents. This study reports current exposures to NMP in the spraying department of an automobile plant using biological monitoring. Two specific metabolites, 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methyl-succinimide (2-HMSI), were analyzed in 69 urine samples of 14 workers exposed to NMP and 9 nonexposed controls. Three different working tasks ('loading' and 'cleaning' of the sprayer system and 'wiping/packing' of the sprayed materials) and three sampling times (preshift, postshift, and preshift of the following day) were studied in exposed workers. Median exposures of 5-HNMP and 2-HMSI in postshift urine of exposed workers were 0.91 and 0.52mg g(-1) creatinine, respectively, whereas median levels in controls were below the limit of detection. Decreased levels of 5-HNMP were observed in preshift urine samples on the following day (0.39mg g(-1) creatinine) in exposed workers, while the concentration of 2-HMSI did not change (0.49mg g(-1) creatinine). Highest exposures occurred during sprayer cleaning with a maximum level of 8.31mg g(-1) creatinine of 5-HNMP in postshift urine. In contrast to 'wipers/packers', no decrease in 5-HNMP could be observed in preshift urine samples on day 2 of the 'loaders' and 'cleaners'. Overall, exposure in terms of 5-HNMP postshift and 2-HMSI preshift of the following day were well below the current biological limit values of the European Union (70 and 20mg g(-1) creatinine). Our results provide initial data on NMP exposure in the automobile industry and suggest that the analysis of 5-HNMP in preshift samples also provides essential information, particularly in situations involving direct handling of liquid NMP-containing formulations.

  13. Proteases in doping control analysis.

    PubMed

    Thevis, M; Maurer, J; Kohler, M; Geyer, H; Schänzer, W

    2007-07-01

    Urine manipulation in sports drug testing has become a serious problem for doping control laboratories, and recent scandals in elite endurance sports have revealed the problem of urine manipulation presumably using proteases, which will impede the detection of drugs such as erythropoietin (EPO) or other peptide hormones. Using commonly accepted analytical strategies, a protocol was developed enabling the determination of elevated protease activities in doping control specimens followed by the visualization of protein degradation and identification of proteases such as chymotrypsin, trypsin and papain. Therefore, protease detection kits based on fluorescein isothiocyanate-labeled casein were employed, and protease concentrations greater than 15 microg/mL of urine entailed subsequent 1-dimensional gel electrophoretic visualization of urinary proteins. The presence of 20 microg of proteases per mL of urine caused a complete degradation of proteins usually observed in urinary matrices ("trace of burning"), while respective proteases were still detected in spiked urine samples after 10 days of storage at + 4 and - 20 degrees C. Identification of target proteases at respective molecular weights was accomplished using bottom-up sequencing approaches based on in-gel digestion of separated enzymes followed by capillary liquid chromatography--Orbitrap tandem mass spectrometry.

  14. Diagnostic value of JC/BK virus antibody immunohistochemistry staining in urine samples from posttransplant immunosuppressed patients in relation to polyomavirus reactivation.

    PubMed

    Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen

    2008-01-01

    To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.

  15. The endothelial lipase protein is promising urinary biomarker for diagnosis of gastric cancer.

    PubMed

    Dong, Xueyan; Wang, Guoqing; Zhang, Guoqing; Ni, Zhaohui; Suo, Jian; Cui, Juan; Cui, Ai; Yang, Qing; Xu, Ying; Li, Fan

    2013-03-19

    Gastric cancer is one of the most common malignant tumors in the world. Finding effective diagnostic biomarkers in urine or serum would represent the most ideal solution to detecting gastric cancer during annual physical examination. This study was to evaluate the potential of endothelial lipase (EL) as a urinary biomarker for diagnosis of gastric cancer. The expression levels of EL was measured using Western blotting and immunohistochemical staining experiments on (tissue, serum, and urine) samples of gastric cancer patients versus healthy people. We also checked the EL levels in the urine samples of other cancer types (lung, colon and rectum cancers) and benign lesions (gastritis and gastric leiomyoma) to check if EL was specific to gastric cancer. We observed a clear separation between the EL expression levels in the urine samples of 90 gastric cancer patients and of 57 healthy volunteers. It was approximately 9.9 fold average decrease of the EL expression levels in the urine samples of gastric cancer compared to the healthy controls (P <0.0001), achieving a 0.967 AUC value for the ROC (receiver operating characteristic) curve, demonstrating it's highly accurate as a diagnostic marker for gastric cancer. Interestingly, the expression levels of EL in tissue and serum samples were not nearly as discriminative as in urine samples (P = 0.90 and P = 0.79). In immunohistochemical experiments, positive expression of the EL protein was found in 67% (8/12) of gastric adjacent noncancerous and in 58% (7/12) of gastric cancer samples. There was no significant statistical in the expression levels of this protein between the gastric cancer and the matching noncancerous tissues (P =0.67). The urinary EL as a highly accurate gastric cancer biomarker that is potentially applicable to the general screening with high sensitivity and specificity. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/4527331618757552.

  16. The endothelial lipase protein is promising urinary biomarker for diagnosis of gastric cancer

    PubMed Central

    2013-01-01

    Background Gastric cancer is one of the most common malignant tumors in the world. Finding effective diagnostic biomarkers in urine or serum would represent the most ideal solution to detecting gastric cancer during annual physical examination. This study was to evaluate the potential of endothelial lipase (EL) as a urinary biomarker for diagnosis of gastric cancer. Methods The expression levels of EL was measured using Western blotting and immunohistochemical staining experiments on (tissue, serum, and urine) samples of gastric cancer patients versus healthy people. We also checked the EL levels in the urine samples of other cancer types (lung, colon and rectum cancers) and benign lesions (gastritis and gastric leiomyoma) to check if EL was specific to gastric cancer. Result We observed a clear separation between the EL expression levels in the urine samples of 90 gastric cancer patients and of 57 healthy volunteers. It was approximately 9.9 fold average decrease of the EL expression levels in the urine samples of gastric cancer compared to the healthy controls (P <0.0001), achieving a 0.967 AUC value for the ROC (receiver operating characteristic) curve, demonstrating it’s highly accurate as a diagnostic marker for gastric cancer. Interestingly, the expression levels of EL in tissue and serum samples were not nearly as discriminative as in urine samples (P = 0.90 and P = 0.79). In immunohistochemical experiments, positive expression of the EL protein was found in 67% (8/12) of gastric adjacent noncancerous and in 58% (7/12) of gastric cancer samples. There was no significant statistical in the expression levels of this protein between the gastric cancer and the matching noncancerous tissues (P =0.67). Conclusions The urinary EL as a highly accurate gastric cancer biomarker that is potentially applicable to the general screening with high sensitivity and specificity. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/4527331618757552 PMID:23510199

  17. Associations between Bisphenol A Exposure and Reproductive Hormones among Female Workers

    PubMed Central

    Miao, Maohua; Yuan, Wei; Yang, Fen; Liang, Hong; Zhou, Zhijun; Li, Runsheng; Gao, Ersheng; Li, De-Kun

    2015-01-01

    The associations between Bisphenol-A (BPA) exposure and reproductive hormone levels among women are unclear. A cross-sectional study was conducted among female workers from BPA-exposed and unexposed factories in China. Women’s blood samples were collected for assay of follicle-stimulating hormone (FSH), luteinizing hormone (LH), 17β-Estradiol (E2), prolactin (PRL), and progesterone (PROG). Their urine samples were collected for BPA measurement. In the exposed group, time weighted average exposure to BPA for an 8-h shift (TWA8), a measure incorporating historic exposure level, was generated based on personal air sampling. Multiple linear regression analyses were used to examine linear associations between urine BPA concentration and reproductive hormones after controlling for potential confounders. A total of 106 exposed and 250 unexposed female workers were included in this study. A significant positive association between increased urine BPA concentration and higher PRL and PROG levels were observed. Similar associations were observed after the analysis was carried out separately among the exposed and unexposed workers. In addition, a positive association between urine BPA and E2 was observed among exposed workers with borderline significance, while a statistically significant inverse association between urine BPA and FSH was observed among unexposed group. The results suggest that BPA exposure may lead to alterations in female reproductive hormone levels. PMID:26506366

  18. Associations between Bisphenol A Exposure and Reproductive Hormones among Female Workers.

    PubMed

    Miao, Maohua; Yuan, Wei; Yang, Fen; Liang, Hong; Zhou, Zhijun; Li, Runsheng; Gao, Ersheng; Li, De-Kun

    2015-10-22

    The associations between Bisphenol-A (BPA) exposure and reproductive hormone levels among women are unclear. A cross-sectional study was conducted among female workers from BPA-exposed and unexposed factories in China. Women's blood samples were collected for assay of follicle-stimulating hormone (FSH), luteinizing hormone (LH), 17β-Estradiol (E2), prolactin (PRL), and progesterone (PROG). Their urine samples were collected for BPA measurement. In the exposed group, time weighted average exposure to BPA for an 8-h shift (TWA8), a measure incorporating historic exposure level, was generated based on personal air sampling. Multiple linear regression analyses were used to examine linear associations between urine BPA concentration and reproductive hormones after controlling for potential confounders. A total of 106 exposed and 250 unexposed female workers were included in this study. A significant positive association between increased urine BPA concentration and higher PRL and PROG levels were observed. Similar associations were observed after the analysis was carried out separately among the exposed and unexposed workers. In addition, a positive association between urine BPA and E2 was observed among exposed workers with borderline significance, while a statistically significant inverse association between urine BPA and FSH was observed among unexposed group. The results suggest that BPA exposure may lead to alterations in female reproductive hormone levels.

  19. Development of a nanogold-based immunochromatographic assay for detection of morphine in urine using the Amor-HK16 monoclonal antibody.

    PubMed

    Dehghannezhad, Ardeshir; Paknejad, Maliheh; Rasaee, Mohammad Javad; Omidfar, Kobra; Seyyed Ebrahimi, Shadi Sadat; Ghahremani, Hossein

    2012-12-01

    A simple, rapid competitive immunochromatography (ICG) strip test was developed to detect morphine in urine samples using a monoclonal antibody produced in-house and conjugated to gold nanoparticles. Hybridoma cells were cultured and the Amor-HK16 monoclonal antibody against morphine was obtained from the supernatant after purification by salting out and passing through a Protein G-Agarose affinity column. Morphine was obtained from morphine sulfate and a C6-hemisuccinate derivative of morphine was prepared, conjugated to bovine serum albumin, and immobilized to a nitrocellulose membrane as the test line. Goat anti-mouse antibody was used as a binder in the control line in the detection zone of the strip. Colloidal gold particles of diameter approximately 20 nm were prepared and conjugated to the monoclonal antibody. The detection limit of the test strip was found to be 2000 ng/mL of morphine in urine samples. Reliability was determined by performing the ICG test on 103 urine samples and comparing the results with those obtained by thin-layer chromatography. The sensitivity of the test was 100%, and the analysis time for the assay was approximately 5 min. The new ICG method was adequately sensitive and accurate for the rapid screening of morphine in urine.

  20. Diagnosis, medical treatment, and prognosis of feline urolithiasis.

    PubMed

    Osborne, C A; Lulich, J P; Thumchai, R; Bartges, J W; Sanderson, S L; Ulrich, L K; Koehler, L A; Bird, K A; Swanson, L L

    1996-05-01

    Radiographic or ultrasonographic evaluation of the urinary tract is required to consistently detect feline uroliths. Evaluation of clinical, laboratory, and radiographic findings facilitate "guesstimation" of the mineral composition of uroliths. Therapy should not be initiated before appropriate samples have been collected for diagnosis. The objectives of medical management of uroliths are to arrest further growth and to promote urolith dissolution by correcting or controlling underlying abnormalities. For therapy to be effective, it must induce undersaturation of urine with calculogenic crystalloids by (1) increasing the solubility of crystalloids in urine, (2) increasing the volume of urine in which crystalloids are dissolved or suspended, and (3) reducing the quantity of calculogenic crystalloids in urine.

  1. Mass spectrometric characterisation of a condensation product between porphobilinogen and indolyl-3-acryloylglycine in urine of patients with acute intermittent porphyria.

    PubMed

    Marcos, Josep; Ibañez, Maria; Ventura, Rosa; Segura, Jordi; To-Figueras, Jordi; Pozo, Oscar J

    2015-07-01

    We document the presence of a previously unknown species in the urine of patients with acute intermittent porphyria (AIP). The compound was fully characterised by liquid chromatography tandem mass spectrometry. Interpretation of both full spectrum acquisition and product ion spectra acquired in positive and negative ionisation modes by quadrupole time of flight MS allowed for the identification of a condensation product arising from porphobilinogen (PBG, increased in the urine of AIP patients) and indolyl-3-acryloylglycine (IAG, derived from indolylacrylic acid and present in human urine). The structure was unequivocally confirmed through comparison between the selected reaction monitoring chromatograms obtained from the urinary species and the condensation product qualitatively synthesised in the laboratory. Owing to the large amounts of both PBG and IAG in urine of AIP patients, the possible ex vivo formation of PBG-IAG in urine samples was evaluated. The product was spontaneously formed at room temperature, at 4 °C and even during storage at -20 °C when spiking a control sample with PBG. A positive correlation was found between PBG and PBG-IAG in samples collected from AIP patients. However, no correlation was found between PBG-IAG and IAG. Purified PBG-IAG did not form the characteristic chromogen after application of p-dimethylaminobenzaldehyde in HCl, thus suggesting that the current techniques used to measure PBG in urine of AIP patients based on Ehlrich's reaction do not detect this newly characterised PBG-IAG fraction. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Basic or extended urine sampling to analyse urine production?

    PubMed

    Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel

    2017-09-01

    Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.

  3. Injectable, sustained-release naltrexone for the treatment of opioid dependence: a randomized, placebo-controlled trial

    PubMed Central

    Comer, Sandra D.; Sullivan, Maria A.; Yu, Elmer; Rothenberg, Jami L.; Kleber, Herbert D.; Kampman, Kyle; Dackis, Charles; O'Brien, Charles P.; Chiang, C. Nora; Hawks, Richard L.

    2013-01-01

    Context Naltrexone is a medication available in oral form that can completely block the effects produced by opioid agonists, such as heroin. However, poor medication compliance with naltrexone has been a major obstacle to the effective treatment of opioid dependence. Objective To evaluate the safety and efficacy of a sustained-release depot formulation of naltrexone in treating opioid dependence. Design, Setting, and Participants Randomized, double-blind, placebo-controlled, 8-week multi-center trial of male and female heroin-dependent patients who participated in the study between September 2000 and November 2003. Participants were stratified by years of heroin use (≥5, <4.9) and gender, and then randomized to receive one of three doses: placebo, 192 mg, or 384 mg depot naltrexone. Doses were administered at the beginning of Week 1 and then again four weeks later at the beginning of Week 5. All participants received twice-weekly relapse prevention therapy, provided observed urine samples, and completed other assessments at each visit. Main Outcome Measures Primary outcome measures were retention in treatment and percentage of opioid-negative urine samples. Results A total of 60 patients were randomized at two centers. Retention in treatment was dose related with 39%, 60%, and 68% of the patients in the placebo, naltrexone 192 mg, and naltrexone 384 mg groups, respectively, remaining in treatment at the end of the two-month treatment period. Analysis of the time to dropout revealed a significant main effect of dose with mean time to dropout of 27, 36, and 48 days, respectively, for the placebo, naltrexone 192 mg, and naltrexone 384 mg groups. The percentage of urine samples negative for opioids varied significantly as a function of dose, as did the percentage of urine samples negative for methadone, cocaine, benzodiazepines, and amphetamine. The percentage of urine samples negative for cannabinoids was not significantly different across groups. When the data were recalculated without the assumption that missing urine samples were positive, however, a main effect of group was not found for any of the drugs tested with the exception of cocaine, where the percentage of cocaine-negative urines was lower in the placebo group. Adverse events were minimal and generally mild in severity. This sustained-release formulation of naltrexone was well tolerated and produced a robust and dose-related increase in treatment retention. Conclusion The present data provide exciting new evidence for the feasibility, efficacy, and tolerability of long-lasting antagonist treatments for opioid dependence. PMID:16461865

  4. Search for Microorganisms in Men with Urologic Chronic Pelvic Pain Syndrome: A Culture-Independent Analysis in the MAPP Research Network.

    PubMed

    Nickel, J Curtis; Stephens, Alisa; Landis, J Richard; Chen, Jun; Mullins, Chris; van Bokhoven, Adrie; Lucia, M Scott; Melton-Kreft, Rachael; Ehrlich, Garth D

    2015-07-01

    We used next-generation, state-of-the-art, culture independent methodology to survey urine microbiota of males with urologic chronic pelvic pain syndrome and control participants enrolled in the MAPP Network to investigate a possible microbial etiology. Male patients with urologic chronic pelvic pain syndrome and matched controls were asked to provide initial, midstream and post-prostatic massage urine specimens. Specimens were analyzed with Ibis T-5000 Universal Biosensor technology to provide comprehensive identification of bacterial and select fungal species. Differences between urologic chronic pelvic pain syndrome and control study participants for the presence of species or species variation in a higher taxonomic grouping (genus) were evaluated using permutational multivariate analysis of variance and logistic regression. Initial and midstream urine specimens were obtained from 110 (post-prostatic massage urine in 67) participants with urologic chronic pelvic pain syndrome and 115 (post-prostatic massage urine in 62) controls. Overall 78, 73 and 54 species (42, 39 and 27 genera) were detected in initial, midstream and post-prostatic massage urine specimens, respectively. Mean (SD) initial, midstream and post-prostatic massage urine species count per person was 1.62 (1.28), 1.38 (1.36) and 1.33 (1.24) for cases, and 1.75 (1.32), 1.23 (1.15) and 1.56 (0.97) for controls, respectively. Overall species and genus composition differed significantly between participants with urologic chronic pelvic pain syndrome and controls in initial stream urine (p=0.002 species level, p=0.004 genus level), with Burkholderia cenocepacia overrepresented in urologic chronic pelvic pain syndrome. No significant differences were observed at any level in midstream or post-prostatic massage urine samples. Assessment of baseline culture-independent microbiological data from male subjects enrolled in the MAPP Network has identified overrepresentation of B. cenocepacia in urologic chronic pelvic pain syndrome. Future studies are planned to further evaluate microbiota associations with variable and changing urologic chronic pelvic pain syndrome symptom patterns. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Urine ethanol concentration and alcohol hangover severity.

    PubMed

    Van de Loo, Aurora; Mackus, Marlou; Korte-Bouws, Gerdien; Brookhuis, Karel; Garssen, Johan; Verster, Joris

    2017-01-01

    The aim of this study was to examine the relationship between urine ethanol concentration and alcohol hangover severity. N = 36 healthy social drinkers participated in a naturalistic study, comprising a hangover day and a control day. N = 18 of them have regular hangovers (the hangover group), while the other N = 18 claim to be hangover immune (hangover-immune group). On each test day at 9.30 am, urine samples were collected. Participants rated their overall hangover severity on a scale from 0 (absent) to 10 (extreme), as well as 18 individual hangover symptoms. Urine ethanol concentration was significantly higher on the hangover day when compared to the control day (p = 0.006). On the hangover day, urine ethanol concentration was significantly lower in the hangover-immune group when compared to the hangover group (p = 0.027). In the hangover-immune group, none of the correlations of urine ethanol concentration with individual hangover symptoms was significant. In contrast, in the hangover group, significant correlations were found with a variety of hangover symptoms, including nausea, concentration problems, sleepiness, weakness, apathy, sweating, stomach pain, thirst, heart racing, anxiety, and sleep problems. Urine ethanol levels are significantly associated with the presence and severity of several hangover symptoms.

  6. A survey of occupational exposure to 4,4'-methylene-bis (2-chloroaniline) (MbOCA) in the UK.

    PubMed

    Cocker, J; Cain, J R; Baldwin, P; McNally, K; Jones, K

    2009-07-01

    The main objective of the study was to gather information about the current controls and levels of exposure to 4,4'-methylene-bis (2-chloroaniline) (MbOCA) in a representative cross section of workplaces that use it to manufacture polyurethane elastomers. The study also aimed to investigate whether controls and guidance could be improved and to investigate exposure to isocyanates in these workplaces using biological monitoring. An occupational hygienist and a field scientist visited the two UK suppliers and 20 out of the 25 workplaces known to be using MbOCA in the UK during 2005 and 2006. They collected air samples, surface wipes, gloves, and urine samples and made observations to assess exposure and the adequacy of controls. All samples were analysed for MbOCA and urine samples were additionally analysed for isocyanate metabolites. A statistical analysis was made of the results. Only 2.5% of the 80 personal inhalation exposures to MbOCA exceeded the workplace exposure limit of 5 microg m(-3) 8-h time-weighted average and 84% were below the limit of detection (LOD). Surface samples (n = 334) were collected from MbOCA users and suppliers and 60% had detectable levels of MbOCA ranging from 0.019 to 400 microg cm(-2). The highest levels were around a hopper, ovens, and the weighing and pouring areas. MbOCA was also detected in 8 of the 75 samples collected from areas not likely to be in contact with MbOCA. At the two suppliers, samples (n = 28) were collected from the outside surfaces of recently imported kegs, pallets, and the floor around kegs. Six samples had detectable levels and four of these (0.2, 0.8, 1, and 6 microg cm(-2)) were from the floor and pallets in both suppliers. The other two positive results were found on the outside rim (18 microg cm(-2)) and side (23 microg cm(-2)) of a keg at one supplier indicating contamination by the manufacturer. Urine samples (n = 79) were collected and 49% were below the LOD for MbOCA and only three samples had levels of MbOCA that exceeded the biological monitoring guidance value (BMGV) of 15 micromol mol(-1) creatinine. The highest urinary MbOCA concentrations were in samples from workers casting and moulding. The 90th percentile of the urine MbOCA results was 8.6 micromol MbOCA per mol creatinine. Urine samples were also analysed for the diamine metabolites of toluene diisocyanate and hexamethylene diisocyanate and 33% had detectable levels with 22 and 13% of results, respectively, above the BMGV for isocyanates (1 micromol isocyanate-derived diamine per mol creatinine). The maximum urinary concentration of toluene diamine and hexane diamine were 15.6 and 10.1 micromol mol(-1) creatinine, respectively. The survey found that the measures used to control exposure to MbOCA could be improved. Although air levels of MbOCA were generally low, there was evidence of spread of surface contamination and poor maintenance of controls such as local exhaust ventilation. A BMGV based on the 90th percentile of data from workplaces with good control would be less than the 90% value of 8.6 micromol mol(-1) creatinine found in this study and suggests that the current BMGV of 15 micromol mol(-1) creatinine is no longer acting as a stimulus to reduce exposure. The metabolites of isocyanates found in urine samples in this study could arise from inhalation exposure to isocyanates or from dermal exposure to either isocyanates or their diamine breakdown product and need further investigation.

  7. Effects of diet composition on mutagenic activity in urine.

    PubMed

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  8. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Usage of a selective media (EMJH-STAFF) in primary culturing of pathogenic leptospires from bovine clinical samples.

    PubMed

    Loureiro, A P; Martins, G; Pinto, P; Narduche, L; Teixeira, R C; Lilenbaum, W

    2015-12-01

    Isolation of local strains is mandatory for the success of control programs. However, clinical samples are typically contaminated by other bacteria, which impair leptospires growth. The purpose of this study was to evaluate the use of a previously reported EMJH-STAFF media in the recovery of pathogenic leptospires from bovine clinical samples, namely urine (n = 123) and vaginal fluid-VF (n = 102). EMJH-STAFF presented less contamination than EMJH (<0·005), which was more evident in VF culture tubes. Nine pure leptospires cultures were obtained, six from urine (4·9%) and three from VF (2·9%). From those, seven grew on EMJH-STAFF, one on EMJH and one in both media. All the isolates were confirmed as pathogenic leptospires by lipL32-PCR, and sequencing of partial rrs showed them to belong to Leptospira noguchii, Leptospira santarosai and Leptospira interrogans species. EMJH-STAFF media was an important tool in the recovery of leptospires from bovine clinical samples. The slow growth of leptospires and overgrowth of co-existing micro-organisms from environmental and microbiota are the major difficult to recovery Leptospira from animal clinical samples. Implementing an efficient control programme is essential to determine circulating leptospires in the region and their reservoirs. This study evaluated the relationship of a selective media (EMJH-STAFF) on the recovery of pathogenic leptospires (Leptospira noguchii, Leptospira santarosai and Leptospira interrogans), from bovine clinical samples (urine and vaginal fluid). EMJH-STAFF seems to be an important tool in obtaining local strains for epidemiological and control purposes. © 2015 The Society for Applied Microbiology.

  10. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  11. Mean population salt intake estimated from 24-h urine samples and spot urine samples: a systematic review and meta-analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce

    2016-02-01

    Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOC IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). The pr...

  13. Novel liquid chromatography-electrospray ionization mass spectrometry method for the quantification in human urine of microbial aromatic acid metabolites derived from dietary polyphenols.

    PubMed

    Gonthier, Marie-Paule; Rios, Laurent Y; Verny, Marie- Anne; Rémésy, Christian; Scalbert, Augustin

    2003-06-15

    An HPLC-ESI-MS-MS method was developed to quantify in human urine fourteen aromatic acids known as metabolites of dietary polyphenols. These metabolites were determined simultaneously in a single 20-min chromatographic analysis with multiple reaction monitoring detection. The inter- and intra-day precisions, calculated from quality control samples were 8.8 and 5.3%, respectively, and the mean accuracy was 2.3%. The method was tested on urine samples collected from one healthy volunteer who consumed a polyphenol-rich diet for 3 days. Increased levels of several aromatic acid metabolites were observed, demonstrating that the method can be used to detect changes in the excretion of microbial metabolites induced by the consumption of polyphenol-containing foods in humans.

  14. Microextraction by Packed Sorbent (MEPS) and Solid-Phase Microextraction (SPME) as Sample Preparation Procedures for the Metabolomic Profiling of Urine

    PubMed Central

    Silva, Catarina; Cavaco, Carina; Perestrelo, Rosa; Pereira, Jorge; Câmara, José S.

    2014-01-01

    For a long time, sample preparation was unrecognized as a critical issue in the analytical methodology, thus limiting the performance that could be achieved. However, the improvement of microextraction techniques, particularly microextraction by packed sorbent (MEPS) and solid-phase microextraction (SPME), completely modified this scenario by introducing unprecedented control over this process. Urine is a biological fluid that is very interesting for metabolomics studies, allowing human health and disease characterization in a minimally invasive form. In this manuscript, we will critically review the most relevant and promising works in this field, highlighting how the metabolomic profiling of urine can be an extremely valuable tool for the early diagnosis of highly prevalent diseases, such as cardiovascular, oncologic and neurodegenerative ones. PMID:24958388

  15. Estimating mean change in population salt intake using spot urine samples.

    PubMed

    Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce

    2017-10-01

    Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P < 0.001). The corresponding result estimated from the spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P < 0.001) using the INTERSALT equation with potassium. There was no evidence that the changes detected by the 24-h collections and estimating equations were different (all P > 0.058). Separate analysis of the unpaired and paired data showed that detection of change by the estimating equations was observed only in the paired data. All the estimating equations based upon spot urine samples identified a similar change in daily salt intake to that detected by the 24-h urine samples. Methods based upon spot urine samples may provide an approach to measuring change in mean population salt intake, although further investigation in larger and more diverse population groups is required. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association

  16. The potential of at-home prediction of the formation of urolithiasis by simple multi-frequency electrical conductivity of the urine and the comparison of its performance with urine ion-related indices, color and specific gravity.

    PubMed

    Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S

    2016-04-01

    It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.

  17. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  18. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  19. Discordant genotyping results using DNA isolated from anti-doping control urine samples.

    PubMed

    Choong, Eva; Schulze, Jenny J; Ericsson, Magnus; Rane, Anders; Ekström, Lena

    2017-07-01

    The UGT2B17 gene deletion polymorphism is known to correlate to urinary concentration of testosterone-glucuronide and hence this genotype exerts a large impact on the testosterone/epitestosterone (T/E) ratio, a biomarker for testosterone doping. The objective of this study was to assess if DNA isolated from athletes' urine samples (n = 713) obtained in routine doping controls could be targeted for genotyping analysis for future integration in the athlete's passport. A control population (n = 21) including both urine and blood DNA was used for genotyping concordance test. Another aim was to study a large group (n = 596) of authentic elite athletes in respect of urinary steroid profile in relation to genetic variation. First we found that the genotype results when using urine-derived DNA did not correlate sufficiently with the genotype obtained from whole blood DNA. Secondly we found males with one or two UGT2B17 alleles had higher T/E (mean 1.63 ± 0.93) than females (mean 1.28 ± 1.08), p˂0.001. Unexpectedly, we found that several male del/del athletes in power sports had a T/E ˃1. If men in power sport exert a different urinary steroid profile needs to be further investigated. The other polymorphisms investigated in the CYP17A1, UGT2B7 and UGT2B15 genes did not show any associations with testosterone and epitestosterone concentrations. Our results show that genotyping using urine samples according to our method is not useful in an anti-doping setting. Instead, it is of importance for the anti-doping test programs to include baseline values in the ABP to minimize any putative impact of genotype. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. High Prolactin Excretion in Patients with Diabetes Mellitus and Impaired Renal Function.

    PubMed

    Triebel, Jakob; Moreno-Vega, Aura Ileana; Vázquez-Membrillo, Miguel; Nava, Gabriel; García-Franco, Renata; López-Star, Ellery; Baldivieso-Hurtado, Olivia; Ochoa, Daniel; Macotela, Yazmín; Bertsch, Thomas; Martinez de la Escalera, Gonzalo; Clapp, Carmen

    2015-01-01

    The metabolic clearance of prolactin (PRL) is partially executed by the kidney. Here, we investigate the urine excretion of PRL in patients with Diabetes Mellitus and renal impairment. Serum and urine samples were collected from male, mestizo patients in central Mexico employing a cross-sectional study design. Ninety-eight individuals had either no diabetes and normal renal function (control), diabetes and normal renal function, or diabetes with impaired renal function. PRL was determined by a chemiluminescent immunometric assay; protein, albumin, and creatinine were evaluated using quantitative colorimetric assays. The results were analyzed using ANOVA-testing. Patients with Diabetes Mellitus and renal impairment had significantly higher urine PRL levels than patients with Diabetes Mellitus and normal renal function and control patients. Higher urine PRL levels were associated with lower glomerular filtration rates, higher serum creatinine, and higher urinary albumin-to-creatinine ratios (UACR). Urine PRL levels correlated positively with UACR. Serum PRL levels were similar among groups. Patients with Diabetes Mellitus and impaired renal function demonstrate a high urinary PRL excretion. Urinary PRL excretion in the context of proteinuria could contribute to PRL dysregulation in renal impairment.

  1. Comparison of Human Papillomavirus Detections in Urine, Vulvar, and Cervical Samples from Women Attending a Colposcopy Clinic

    PubMed Central

    Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas

    2014-01-01

    While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879

  2. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Mass spectrometric characterization of the hypoxia-inducible factor (HIF) stabilizer drug candidate BAY 85-3934 (molidustat) and its glucuronidated metabolite BAY-348, and their implementation into routine doping controls.

    PubMed

    Dib, Josef; Mongongu, Cynthia; Buisson, Corinne; Molina, Adeline; Schänzer, Wilhelm; Thuss, Uwe; Thevis, Mario

    2017-01-01

    The development of new therapeutics potentially exhibiting performance-enhancing properties implicates the risk of their misuse by athletes in amateur and elite sports. Such drugs necessitate preventive anti-doping research for consideration in sports drug testing programmes. Hypoxia-inducible factor (HIF) stabilizers represent an emerging class of therapeutics that allows for increasing erythropoiesis in patients. BAY 85-3934 is a novel HIF stabilizer, which is currently undergoing phase-2 clinical trials. Consequently, the comprehensive characterization of BAY 85-3934 and human urinary metabolites as well as the implementation of these analytes into routine doping controls is of great importance. The mass spectrometric behaviour of the HIF stabilizer drug candidate BAY 85-3934 and a glucuronidated metabolite (BAY-348) were characterized by electrospray ionization-(tandem) mass spectrometry (ESI-MS(/MS)) and multiple-stage mass spectrometry (MS n ). Subsequently, two different laboratories established different analytical approaches (one each) enabling urine sample analyses by employing either direct urine injection or solid-phase extraction. The methods were cross-validated for the metabolite BAY-348 that is expected to represent an appropriate target analyte for human urine analysis. Two test methods allowing for the detection of BAY-348 in human urine were applied and cross-validated concerning the validation parameters specificity, linearity, lower limit of detection (LLOD; 1-5 ng/mL), ion suppression/enhancement (up to 78%), intra- and inter-day precision (3-21%), recovery (29-48%), and carryover. By means of ten spiked test urine samples sent blinded to one of the participating laboratories, the fitness-for-purpose of both assays was provided as all specimens were correctly identified applying both testing methods. As no post-administration study samples were available, analyses of authentic urine specimens remain desirable. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. LC-ESI-MS/MS on an ion trap for the determination of LSD, iso-LSD, nor-LSD and 2-oxo-3-hydroxy-LSD in blood, urine and vitreous humor.

    PubMed

    Favretto, Donata; Frison, Giampietro; Maietti, Sergio; Ferrara, Santo Davide

    2007-07-01

    A method has been developed for the simultaneous determination of lysergic acid diethylamide (LSD), its epimer iso-LSD, and its main metabolites nor-LSD and 2-oxo-3-hydroxy LSD in blood, urine, and, for the first time, vitreous humor samples. The method is based on liquid/liquid extraction and liquid chromatography-multiple mass spectrometry detection in an ion trap mass spectrometer, in positive ion electrospray ionization conditions. Five microliter of sample are injected and analysis time is 12 min. The method is specific, selective and sensitive, and achieves limits of quantification of 20 pg/ml for both LSD and nor-LSD in blood, urine, and vitreous humor. No significant interfering substance or ion suppression was identified for LSD, iso-LSD, and nor-LSD. The interassay reproducibilities for LSD at 20 pg/ml and 2 ng/ml in urine were 8.3 and 5.6%, respectively. Within-run precision using control samples at 20 pg/ml and 2 ng/ml was 6.9 and 3.9%. Mean recoveries of two concentrations spiked into drug free samples were in the range 60-107% in blood, 50-105% in urine, and 65-105% in vitreous humor. The method was successfully applied to the forensic determination of postmortem LSD levels in the biological fluids of a multi drug abuser; for the first time, LSD could be detected in vitreous humor.

  5. Occupational exposure to bisphenol A (BPA) in a plastic injection molding factory in Malaysia.

    PubMed

    Kouidhi, Wided; Thannimalay, Letchumi; Soon, Chen Sau; Ali Mohd, Mustafa

    2017-07-14

    The purpose of this study has been to assess ambient bisphenol A (BPA) levels in workplaces and urine levels of workers and to establish a BPA database for different populations in Malaysia. Urine samples were collected from plastic factory workers and from control subjects after their shift. Air samples were collected using gas analyzers from 5 sampling positions in the injection molding unit work area and from ambient air. The level of BPA in airborne and urine samples was quantified by the gas chromatography mass spectrometry - selected ion monitoring (GCMS-SIM) analysis. Bisphenol A was detected in the median range of 8-28.3 ng/m³ and 2.4-3.59 ng/m³ for the 5 sampling points in the plastic molding factory and in the ambient air respectively. The median urinary BPA concentration was significantly higher in the workers (3.81 ng/ml) than in control subjects (0.73 ng/ml). The urinary BPA concentration was significantly associated with airborne BPA levels (ρ = 0.55, p < 0.01). Our findings provide the first evidence that workers in a molding factory in Malaysia are occupationally exposed to BPA. Int J Occup Med Environ Health 2017;30(5):743-750. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  6. Total morphine stability in urine specimens stored under various conditions.

    PubMed

    Chang, B L; Huang, M K; Tsai, Y Y

    2000-09-01

    The stability of total morphine in urine stored under various conditions was studied using control and experimental specimens. Samples in the control group were prepared using drug-free urine spiked with morphine at three concentration levels (300, 1000, and 2500 ng/mL), each with the pH adjusted to 5.5, 6.5, and 7.5. Samples in the experimental group came from 20 alleged heroin addicts (provided by Taipei Municipal Psychiatric Hospital). Samples in both groups were divided into two categories--one with and one without the precipitate (formed at 0 degrees C) removed. Samples in each of these two categories were further divided into two sub-groups--one with and one without sodium azide (0.05%) added. Total morphine contents in these samples were first determined by gas chromatography-mass spectrometry prior to storage and at 6, 12, 18, and 24 months following storage at -20, 4, 25, and 35 degrees C. Effects of sample treatment (azide addition and precipitate removal), pH, and storage temperature and length were evaluated by examining the percentage of total morphine remaining at the four time intervals following the initial determination. Major findings were as follows: (1) total morphine decomposition was minimal when stored for 12 months at -20 degrees C, which is a common current practice; (2) samples with lower initial sample pH had slower total morphine decomposition rates; and (3) azide addition appeared to have no detectable effect, whereas precipitate removal appeared to marginally reduce the decomposition rate, especially for samples with lower pH.

  7. DMSO Assisted Electrospray Ionization for the Detection of Small Peptide Hormones in Urine by Dilute-and-Shoot-Liquid-Chromatography-High Resolution Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Judák, Péter; Grainger, Janelle; Goebel, Catrin; Van Eenoo, Peter; Deventer, Koen

    2017-08-01

    The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed.

  8. Six-month trial of bupropion with contingency management for cocaine dependence in a methadone-maintained population.

    PubMed

    Poling, James; Oliveto, Alison; Petry, Nancy; Sofuoglu, Mehmet; Gonsai, Kishorchandra; Gonzalez, Gerardo; Martell, Bridget; Kosten, Thomas R

    2006-02-01

    No effective pharmacotherapies exist for cocaine dependence, although contingency management (CM) has demonstrated efficacy. To compare the efficacy of bupropion hydrochloride and CM for reducing cocaine use in methadone hydrochloride-maintained individuals. This 25-week, placebo-controlled, double-blind trial randomly assigned participants to 1 of 4 treatment conditions: CM and placebo (CMP), CM and 300 mg/d of bupropion hydrochloride (CMB), voucher control and placebo (VCP), or voucher control and bupropion (VCB). Outpatient clinic at the Veterans Affairs Connecticut Healthcare System. A total of 106 opiate-dependent, cocaine-abusing individuals. All study participants received methadone hydrochloride (range, 60-120 mg). Participants receiving bupropion hydrochloride were given 300 mg/d beginning at week 3. In the CM conditions, each urine sample negative for both opioids and cocaine resulted in a monetary-based voucher that increased for consecutively drug-free urine samples during weeks 1 to 13. Completion of abstinence-related activities also resulted in a voucher. During weeks 14 to 25, only completion of activities was reinforced in the CM group, regardless of sample results. The voucher control groups received vouchers for submitting urine samples, regardless of results, throughout the study. Thrice-weekly urine toxicologic test results for cocaine and heroin. Groups did not differ in baseline characteristics or retention rates. Opiate use decreased significantly, with all treatment groups attaining equivalent amounts of opiate use at the end of the study. In the CMB group, the proportion of cocaine-positive samples significantly decreased during weeks 3 to 13 (P<.001) relative to week 3 and remained low during weeks 14 to 25. In the CMP group, cocaine use significantly increased during weeks 3 to 13 (P<.001) relative to week 3, but then cocaine use significantly decreased relative to the initial slope during weeks 14 to 25 (P<.001). In contrast, by treatment end, the VCB and VCP groups showed no significant improvement in cocaine use. These findings suggest that combining CM with bupropion for the treatment of cocaine addiction may significantly improve outcomes relative to bupropion alone.

  9. Quantification of vosaroxin and its metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nijenhuis, C M; Lucas, L; Rosing, H; Jamieson, G; Fox, J A; Schellens, J H M; Beijnen, J H

    2016-08-01

    Vosaroxin is a first-in-class anticancer quinolone derivative topoisomerase II inhibitor that is currently in development in combination with cytarabine for the treatment of acute myeloid leukemia (AML). To investigate vosaroxin pharmacokinetics (PK) in patients, liquid chromatography tandem mass spectrometry (LC-MS/MS) assays to quantify vosaroxin and the two metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine were developed and validated. Immediately after collection the samples were stored at -80°C. Prior to analysis, the plasma samples were subjected to protein precipitation and the urine samples were diluted. For both assays the reconstituted extracts were injected on a Symmetry Shield RP8 column and gradient elution was applied using 0.1% formic acid in water and acetonitrile-methanol (50:50, v/v). Analyses were performed with a triple quadruple mass spectrometer in positive-ion mode. A deuterated isotope of vosaroxin was used as internal standard for the quantification. The validated assays quantify vosaroxin and N-desmethylvosaroxin in the concentration range of 2-500ng/mL in plasma and urine. For O-desmethylvosaroxin the concentration range of 4-500ng/mL in plasma and urine was validated. Dilution integrity experiments show that samples can be diluted 25 fold in control matrix prior to analysis. The expanded concentration range for plasma and urine for vosaroxin and N-desmethylvosaroxin is therefore from 2 to 15,000ng/mL and in plasma for O-desmethylvosaroxin from 4 to 15,000ng/mL. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Mutagenicity studies of urine and faecal samples from rats treated orally with the food colourings Brown FK and Red 2G.

    PubMed

    Edwards, C N; Combes, R D

    1984-08-01

    Urine and faecal extracts from rats given Brown FK or Red 2G orally (800 mg/kg body weight) were investigated for mutagenicity. Extracts were subjected to liquid fluctuation and plate incorporation assays with Salmonella typhimurium strains TA98 and TA100 in the presence and absence of liver microsomes and/or a beta-glucuronidase-sulphatase preparation. Urine from Red 2G-treated rats only exhibited direct activity when coloured fractions from polyamide-column concentrates were tested with TA100. All other urines, as well as aqueous and ether faecal extracts from animals receiving either colouring, were no more mutagenic than the respective control extracts obtained from the same animals prior to dosing.

  11. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  12. Efficacy of new low-cost filtration device for recovering Schistosoma haematobium eggs from urine.

    PubMed

    Gyorkos, T W; Ramsan, M; Foum, A; Khamis, I S

    2001-07-01

    A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs.

  13. Mass spectral analysis of urine proteomic profiles of dairy cows suffering from clinical ketosis.

    PubMed

    Xu, Chuang; Shu, Shi; Xia, Cheng; Wang, Pengxian; Sun, Yuhang; Xu, Chuchu; Li, Changsheng

    2015-01-01

    Ketosis is an important metabolic disorder in dairy cows during the transition period. The urine proteomics of ketosis has not been investigated using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). The aim is to determine differences between urine proteomic profiles of healthy cows and those with clinical ketosis, and facilitate studies of the underlying physiological and biochemical mechanisms that lead to liver pathology in ketosis. We analyzed the urine samples of 20 cows with clinical ketosis (group 1) and 20 control cows (group 2) using SELDI-TOF-MS. Thirty-nine peptide peaks differed between both groups. Polypeptides corresponding to 26 of these differential peptide peaks were identified using the SWISS-PROT protein database. We found that the peaks of 11 distinct polypeptides from the urine samples of the ketosis group were significantly reduced, compared with those of the control group as based on the Wilcoxon rank sum test. Among these were VGF (non-acronymic) protein, amyloid precursor protein, serum amyloid A (SAA), fibrinogen, C1INH, apolipoprotein C-III, cystatin C, transthyretin, hepcidin, human neutrophil peptides, and osteopontin. These proteins may represent novel biomarkers of the metabolic changes that occur in dairy cows with ketosis. Our results will help to better understand the physiological changes and pathogenesis observed in cows with ketosis. The SELDI-TOF-MS can be used to understand the physiological and biochemical mechanisms of ketosis and identify biomarkers of the disease.

  14. Comparing metabolite profiles of habitual diet in serum and urine123

    PubMed Central

    Playdon, Mary C; Sampson, Joshua N; Cross, Amanda J; Sinha, Rashmi; Guertin, Kristin A; Moy, Kristin A; Rothman, Nathaniel; Irwin, Melinda L; Mayne, Susan T; Stolzenberg-Solomon, Rachael; Moore, Steven C

    2016-01-01

    Background: Diet plays an important role in chronic disease etiology, but some diet-disease associations remain inconclusive because of methodologic limitations in dietary assessment. Metabolomics is a novel method for identifying objective dietary biomarkers, although it is unclear what dietary information is captured from metabolites found in serum compared with urine. Objective: We compared metabolite profiles of habitual diet measured from serum with those measured from urine. Design: We first estimated correlations between consumption of 56 foods, beverages, and supplements assessed by a food-frequency questionnaire, with 676 serum and 848 urine metabolites identified by untargeted liquid chromatography mass spectrometry, ultra-high performance liquid chromatography tandem mass spectrometry, and gas chromatography mass spectrometry in a colon adenoma case–control study (n = 125 cases and 128 controls) while adjusting for age, sex, smoking, fasting, case-control status, body mass index, physical activity, education, and caloric intake. We controlled for multiple comparisons with the use of a false discovery rate of <0.1. Next, we created serum and urine multiple-metabolite models to predict food intake with the use of 10-fold crossvalidation least absolute shrinkage and selection operator regression for 80% of the data; predicted values were created in the remaining 20%. Finally, we compared predicted values with estimates obtained from self-reported intake for metabolites measured in serum and urine. Results: We identified metabolites associated with 46 of 56 dietary items; 417 urine and 105 serum metabolites were correlated with ≥1 food, beverage, or supplement. More metabolites in urine (n = 154) than in serum (n = 39) were associated uniquely with one food. We found previously unreported metabolite associations with leafy green vegetables, sugar-sweetened beverages, citrus, added sugar, red meat, shellfish, desserts, and wine. Prediction of dietary intake from multiple-metabolite profiles was similar between biofluids. Conclusions: Candidate metabolite biomarkers of habitual diet are identifiable in both serum and urine. Urine samples offer a valid alternative or complement to serum for metabolite biomarkers of diet in large-scale clinical or epidemiologic studies. PMID:27510537

  15. [Measurement of bronchoconstrictive eicosanoids in chronic obstructive pulmonary disease].

    PubMed

    Gross-Sondej, Iwona; Soja, Jerzy; Sładek, Krzysztof; Pulka, Grażyna; Skucha, Wojciech; Niżankowska-Mogilnicka, Ewa

    2012-01-01

    The aim of the study was the evaluation of the concentration of 9α11β prostaglandin F(2) - a stable metabolite of prostaglandin D(2) (PGD(2)) and leukotriene E(4) (LTE(4)) in stable and exacerbated COPD patients. 29 COPD patients aged 73 ± 8.34, mean FEV1 = 48.64 ± 15.75% of predictive value and 29 healthy controls aged 57.48 ± 10.86, mean FEV1 = 97.17 ± 13.81% of predictive value participated in this study. Samples of urine and blood were taken from COPD patients during exacerbation and in stable state of the disease; LTE(4) was determined in urine using commercial enzyme immunoassay (EIA) and 9α11β prostaglandin F(2) (9α11βPGF(2)) - stable metabolite of PGD(2) was evaluated in blood and urine using GC/MS. LTE(4) concentration in urine (677.15 vs. 436.4 pg/mg of creatinine; p = 0.035) and 9α11βPGF(2) in blood serum (5.35 vs. 3.07 pg/ml; p = 0.007) were significantly higher in exacerbated COPD patients than in control group. There was no difference in LTE(4) level in urine and 9α11βPGF2 in blood serum between exacerbated and stable COPD. The urinary 9α11βPGF(2) concentration did not differ between all studied groups. We found a positive correlation between smoking history and the urine LTE(4) level (r = 0.395; p = 0.002) as well as blood 9α11βPGF(2) concentration (r = 0.603; p = 0.001) in COPD patients. 9α11βPGF(2) and LTE(4) level in urine did not differ between the stable COPD group and the control group. We also did not find any difference between LTE4 level in urine and 9α11βPGF(2) in blood and urine between exacerbated and stable COPD. Finally, LTE(4) concentration in urine and 9α11βPGF(2) in blood occurred to be significantly higher in exacerbated COPD patients than in control group.

  16. Biological monitoring of workers exposed to 4,4'-methylenediphenyl diisocyanate (MDI) in 19 French polyurethane industries.

    PubMed

    Robert, A; Ducos, P; Francin, J M; Marsan, P

    2007-04-01

    To study the range of urinary levels of 4,4'-methylenedianiline (MDA), a metabolite of methylenediphenyl diisocyanate (MDI), across factories in the polyurethane industries and to evaluate the validity of this biomarker to assess MDI occupational exposure. Workers exposed to MDI, as well as non-occupationally exposed subjects, were studied and pre- and post-shift urine samples were collected from 169 workers of 19 French factories and 120 controls. Details on work activities and practices were collected by a questionnaire and workers were classified into three job categories. The identification and quantification of the total urinary MDA were performed by high-performance liquid chromatography with electrochemical detection (HPLC/EC). For all the factories, MDA was detectable in 73% of the post-shift urine samples. These post-shift values, in the range of <0.10 (detection limit)-23.60 microg/l, were significantly higher than those of the pre-shift samples. Urinary MDA levels in the control group were in the range of < 0.10-0.80 microg/l. The degree of automation of the mixing operation (polyols and MDI) appears as a determinant in the extent of exposure levels. The highest amounts of MDA in urine were found in the spraying or hot processes. The excretion levels of the workers directly exposed to the hardener containing the MDI monomer were significantly higher than those of the other workers. In addition, skin exposure to MDI monomer or to polyurethane resin during the curing step were always associated with significant MDA levels in urine. Total MDA in post-shift urine samples is a reliable biomarker to assess occupational exposure to MDI in various industrial applications and to help factories to improve their manufacturing processes and working practices. A biological guiding value not exceeding 7 microg/l (5 microg/g creatinine) could be proposed in France.

  17. A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry☆

    PubMed Central

    Rota, Cristina; Cristoni, Simone; Trenti, Tommaso; Cariani, Elisabetta

    2013-01-01

    Oxidative attack to DNA is of particular interest since DNA modifications can lead to heritable mutations. The most studied product of DNA oxidation is 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG). While 8-oxodG determination in blood and tissue cells is prone to artifacts, its measurement in urine employing liquid chromatography tandem mass spectrometry (LC-MS/MS) has gained more and more interest for increased reliability. LC-MS/MS can be affected by matrix effects and this is particularly true when ion trap is used as MS analyzer, due to ion accumulation in the trap and related space charge effect. In the present work, we have developed a LC-MS/MS method where the combination of cation exchange and reverse phase solid phases resulted in LC separation optimization. This together with the employment of an isotopically labeled internal standard, allowed the usage of ion trap LC-MS/MS, typically not employed for quantitative measurement in biological samples, for the measurement of 8-oxodG in urine samples from control populations. Four different urine matrices were employed for method validation. Limit of quantitation was set at least at 0.5 ng/ml. While analyzing urine samples from healthy volunteers, 8-oxodG levels reported as ng/ml were statistically different comparing males with females (p<0.05, Mann Whitney test); while comparing results normalized for creatinine no statistical significant difference was found. Mean urinary 8-oxodG level found in healthy volunteers was 1.16±0.46 nmol/mmol creatinine. The present method by enhancing at best the chromatographic performances allows the usage of ion trap LC-MS/MS for the measurement of 8-oxodG in urine samples from control populations. PMID:24251117

  18. Urine testing for designer steroids by liquid chromatography with androgen bioassay detection and electrospray quadrupole time-of-flight mass spectrometry identification.

    PubMed

    Nielen, Michel W F; Bovee, Toine F H; van Engelen, Marcel C; Rutgers, Paula; Hamers, Astrid R M; van Rhijn, J Hans A; Hoogenboom, L Ron A P

    2006-01-15

    New anabolic steroids show up occasionally in sports doping and in veterinary control. The discovery of these designer steroids is facilitated by findings of illicit preparations, thus allowing bioactivity testing, structure elucidation using NMR and mass spectrometry, and final incorporation in urine testing. However, as long as these preparations remain undiscovered, new designer steroids are not screened for in routine sports doping or veterinary control urine tests since the established GC/MS and LC/MS/MS methods are set up for the monitoring of a few selected ions or MS/MS transitions of known substances only. In this study, the feasibility of androgen bioactivity testing and mass spectrometric identification is being investigated for trace analysis of designer steroids in urine. Following enzymatic deconjugation and a generic solid-phase extraction, the samples are analyzed by gradient LC with effluent splitting toward two identical 96-well fraction collectors. One well plate is used for androgen bioactivity detection using a novel robust yeast reporter gene bioassay yielding a biogram featuring a 20-s time resolution. The bioactive wells direct the identification efforts to the corresponding well numbers in the duplicate plate. These are subjected to high-resolution LC using a short column packed with 1.7-microm C18 material and coupled with electrospray quadrupole time-of-flight mass spectrometry (LC/QTOFMS) with accurate mass measurement. Element compositions are calculated and used to interrogate electronic substance databases. The feasibility of this approach for doping control is demonstrated via the screening of human urine samples spiked with the designer anabolic steroid tetrahydrogestrinone. Application of the proposed methodology, complementary to the established targeted urine screening for known anabolics, will increase the chance of finding unknown emerging designer steroids, rather then being solely dependent on findings of the illicit preparations themselves.

  19. Identification of urine protein biomarkers with the potential for early detection of lung cancer.

    PubMed

    Zhang, Hongjuan; Cao, Jing; Li, Lin; Liu, Yanbin; Zhao, Hong; Li, Nan; Li, Bo; Zhang, Aiqun; Huang, Huanwei; Chen, She; Dong, Mengqiu; Yu, Lei; Zhang, Jian; Chen, Liang

    2015-07-02

    Lung cancer is the leading cause of cancer-related deaths and has an overall 5-year survival rate lower than 15%. Large-scale clinical trials have demonstrated a significant relative reduction in mortality in high-risk individuals with low-dose computed tomography screening. However, biomarkers capable of identifying the most at-risk population and detecting lung cancer before it becomes clinically apparent are urgently needed in the clinic. Here, we report the identification of urine biomarkers capable of detecting lung cancer. Using the well-characterized inducible Kras (G12D) mouse model of lung cancer, we identified alterations in the urine proteome in tumor-bearing mice compared with sibling controls. Marked differences at the proteomic level were also detected between the urine of patients and that of healthy population controls. Importantly, we identified 7 proteins commonly found to be significantly up-regulated in both tumor-bearing mice and patients. In an independent cohort, we showed that 2 of the 7 proteins were up-regulated in urine samples from lung cancer patients but not in those from controls. The kinetics of these proteins correlated with the disease state in the mouse model. These tumor biomarkers could potentially aid in the early detection of lung cancer.

  20. Development of a universal metabolome-standard method for long-term LC-MS metabolome profiling and its application for bladder cancer urine-metabolite-biomarker discovery.

    PubMed

    Peng, Jun; Chen, Yi-Ting; Chen, Chien-Lun; Li, Liang

    2014-07-01

    Large-scale metabolomics study requires a quantitative method to generate metabolome data over an extended period with high technical reproducibility. We report a universal metabolome-standard (UMS) method, in conjunction with chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS), to provide long-term analytical reproducibility and facilitate metabolome comparison among different data sets. In this method, UMS of a specific type of sample labeled by an isotope reagent is prepared a priori. The UMS is spiked into any individual samples labeled by another form of the isotope reagent in a metabolomics study. The resultant mixture is analyzed by LC-MS to provide relative quantification of the individual sample metabolome to UMS. UMS is independent of a study undertaking as well as the time of analysis and useful for profiling the same type of samples in multiple studies. In this work, the UMS method was developed and applied for a urine metabolomics study of bladder cancer. UMS of human urine was prepared by (13)C2-dansyl labeling of a pooled sample from 20 healthy individuals. This method was first used to profile the discovery samples to generate a list of putative biomarkers potentially useful for bladder cancer detection and then used to analyze the verification samples about one year later. Within the discovery sample set, three-month technical reproducibility was examined using a quality control sample and found a mean CV of 13.9% and median CV of 9.4% for all the quantified metabolites. Statistical analysis of the urine metabolome data showed a clear separation between the bladder cancer group and the control group from the discovery samples, which was confirmed by the verification samples. Receiver operating characteristic (ROC) test showed that the area under the curve (AUC) was 0.956 in the discovery data set and 0.935 in the verification data set. These results demonstrated the utility of the UMS method for long-term metabolomics and discovering potential metabolite biomarkers for diagnosis of bladder cancer.

  1. Should acidification of urine be performed before the analysis of calcium, phosphate and magnesium in the presence of crystals?

    PubMed

    Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol

    2013-11-15

    Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.

  2. Incontinence medication response relates to the female urinary microbiota.

    PubMed

    Thomas-White, Krystal J; Hilt, Evann E; Fok, Cynthia; Pearce, Meghan M; Mueller, Elizabeth R; Kliethermes, Stephanie; Jacobs, Kristin; Zilliox, Michael J; Brincat, Cynthia; Price, Travis K; Kuffel, Gina; Schreckenberger, Paul; Gai, Xiaowu; Brubaker, Linda; Wolfe, Alan J

    2016-05-01

    Many adult women have resident urinary bacteria (urinary microbiome/microbiota). In adult women affected by urinary urgency incontinence (UUI), the etiologic and/or therapeutic role of the urinary microbiome/microbiota remains unknown. We hypothesized that microbiome/microbiota characteristics would relate to clinically relevant treatment response to UUI medication per os. Adult women initiating medication treatment orally for UUI and a comparator group of unaffected women were recruited in a tertiary care health-care system. All participants provided baseline clinical data and urine samples. Women with UUI were given 5 mg solifenacin, with potential dose escalation to 10 mg for inadequate UUI symptom control at 4 weeks. Additional data and urine samples were collected from women with UUI at 4 and 12 weeks. The samples were assessed using 16S ribosomal RNA (rRNA) gene sequencing and enhanced quantitative urine culturing. The primary outcome was treatment response as measured by the validated Patient Global Symptom Control (PGSC) questionnaire. Clinically relevant UUI symptom control was defined as a 4 or 5 score on the PGSC. Diversity and composition of the urinary microbiome/microbiota of women with and without UUI differed at baseline. Women with UUI had more bacteria and a more diverse microbiome/microbiota. The clinical response to solifenacin in UUI participants was related to baseline microbiome/microbiota, with responders more likely to have fewer bacteria and a less diverse community at baseline. Nonresponders had a more diverse community that often included bacteria not typically found in responders. Knowledge of an individual's urinary microbiome/microbiota may help refine UUI treatment. Complementary tools, DNA sequencing, and expanded urine culture provide information about bacteria that appear to be related to UUI incontinence status and treatment response in this population of adult women.

  3. A randomized controlled trial of ethyl glucuronide-based contingency management for outpatients with co-occurring alcohol use disorders and serious mental illness

    PubMed Central

    McDonell, Michael G.; Leickly, Emily; McPherson, Sterling; Skalisky, Jordan; Srebnik, Debra; Angelo, Frank; Vilardaga, Roger; Nepom, Jenny R.; Roll, John M.; Ries, Richard K.

    2017-01-01

    Objective To determine if a contingency management intervention using the ethyl glucuronide (EtG) alcohol biomarker resulted in increased alcohol abstinence in outpatients with co-occurring serious mental illnesses. Secondary objectives were to determine if contingency management was associated with changes in heavy drinking, treatment attendance, drug use, cigarette smoking, psychiatric symptoms, and HIV-risk behavior. Method Seventy-nine (37% female, 44% non-white) outpatients with serious mental illness and alcohol dependence receiving treatment as usual completed a 4-week observation period and were randomized to 12-weeks of contingency management for EtG-negative urine samples and addiction treatment attendance, or reinforcement only for study participation. Contingency management included the variable magnitude of reinforcement “prize draw” procedure contingent on EtG-negative samples (<150 ng/mL) three times a week and weekly gift cards for outpatient treatment attendance. Urine EtG, drug test, and self-report outcomes were assessed during the 12-week intervention and 3-month follow-up periods. Results Contingency management participants were 3.1 times (95% CI: 2.2, 4.5) more likely to submit an EtG-negative urine test during the 12-week intervention period, attaining nearly 1.5 weeks of additional abstinence relative to controls. Contingency management participants had significantly lower mean EtG levels, reported less drinking and fewer heavy drinking episodes, and were more likely to submit stimulant-negative urine and smoking-negative breath samples, relative to controls. Differences in self-reported alcohol use were maintained at the 3-month follow-up. Conclusions This is the first randomized trial utilizing an accurate and validated biomarker (EtG) to demonstrate the efficacy of contingency management for alcohol dependence in outpatients with serious mental illness. PMID:28135843

  4. A Randomized Controlled Trial of Ethyl Glucuronide-Based Contingency Management for Outpatients With Co-Occurring Alcohol Use Disorders and Serious Mental Illness.

    PubMed

    McDonell, Michael G; Leickly, Emily; McPherson, Sterling; Skalisky, Jordan; Srebnik, Debra; Angelo, Frank; Vilardaga, Roger; Nepom, Jenny R; Roll, John M; Ries, Richard K

    2017-04-01

    The authors examined whether a contingency management intervention using the ethyl glucuronide (EtG) alcohol biomarker resulted in increased alcohol abstinence in outpatients with co-occurring serious mental illnesses. Secondary objectives were to determine whether contingency management was associated with changes in heavy drinking, treatment attendance, drug use, cigarette smoking, psychiatric symptoms, and HIV-risk behavior. Seventy-nine (37% female, 44% nonwhite) outpatients with serious mental illness and alcohol dependence receiving treatment as usual completed a 4-week observation period and were randomly assigned to 12 weeks of contingency management for EtG-negative urine samples and addiction treatment attendance, or reinforcement only for study participation. Contingency management included the variable magnitude of reinforcement "prize draw" procedure contingent on EtG-negative samples (<150 ng/mL) three times a week and weekly gift cards for outpatient treatment attendance. Urine EtG, drug test, and self-report outcomes were assessed during the 12-week intervention and 3-month follow-up periods. Contingency management participants were 3.1 times (95% CI=2.2-4.5) more likely to submit an EtG-negative urine test during the 12-week intervention period, attaining nearly 1.5 weeks of additional alcohol abstinence compared with controls. Contingency management participants had significantly lower mean EtG levels, reported less drinking and fewer heavy drinking episodes, and were more likely to submit stimulant-negative urine and smoking-negative breath samples, compared with controls. Differences in self-reported alcohol use were maintained at the 3-month follow-up. This is the first randomized trial utilizing an accurate and validated biomarker (EtG) to demonstrate the efficacy of contingency management for alcohol dependence in outpatients with serious mental illness.

  5. Urine osmolality in the US population: Implications for environmental biomonitoring

    PubMed Central

    Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana

    2018-01-01

    Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670

  6. Differentiating Medicated Patients Suffering from Major Depressive Disorder from Healthy Controls by Spot Urine Measurement of Monoamines and Steroid Hormones

    PubMed Central

    Wijaya, Chandra S.; Lee, Jovia J. Z.; Husain, Syeda F.; Ho, Cyrus S. H.; McIntyre, Roger S.; Tam, Wilson W.

    2018-01-01

    Introduction: Major Depressive Disorder (MDD) is a common psychiatric disorder. Currently, there is no objective, cost-effective and non-invasive method to measure biological markers related to the pathogenesis of MDD. Previous studies primarily focused on urinary metabolite markers which are not proximal to the pathogenesis of MDD. Herein, we compare urinary monoamines, steroid hormones and the derived ratios amongst MDD when compared to healthy controls. Methods: Morning urine samples of medicated patients suffering from MDD (n = 47) and healthy controls (n = 41) were collected. Enzyme-linked immunosorbent assay (ELISA) was performed to measure five biomarkers: cortisol, dopamine, noradrenaline, serotonin and sulphate derivative of dehydroepiandrosterone (DHEAS). The mean urinary levels and derived ratios of monoamines and steroid hormones were compared between patients and controls to identify potential biomarkers. The receiver operative characteristic curve (ROC) analysis was conducted to evaluate the diagnostic performance of potential biomarkers. Results: Medicated patients with MDD showed significantly higher spot urine ratio of DHEAS/serotonin (1.56 vs. 1.19, p = 0.004) and lower ratio of serotonin/dopamine (599.71 vs. 888.60, p = 0.008) than healthy controls. A spot urine serotonin/dopamine ratio cut-off of >667.38 had a sensitivity of 73.2% and specificity of 51.1%. Conclusions: Our results suggest that spot urine serotonin/dopamine ratio can be used as an objective diagnostic method for adults with MDD. PMID:29701669

  7. Doping control container for urine stabilization: a pilot study.

    PubMed

    Tsivou, Maria; Giannadaki, Evangelia; Hooghe, Fiona; Roels, Kris; Van Gansbeke, Wim; Garribba, Flaminia; Lyris, Emmanouil; Deventer, Koen; Mazzarino, Monica; Donati, Francesco; Georgakopoulos, Dimitrios G; Van Eenoo, Peter; Georgakopoulos, Costas G; de la Torre, Xavier; Botrè, Francesco

    2017-05-01

    Urine collection containers used in the doping control collection procedure do not provide a protective environment for urine, against degradation by microorganisms and proteolytic enzymes. An in-house chemical stabilization mixture was developed to tackle urine degradation problems encountered in human sport samples, in cases of microbial contamination or proteolytic activity. The mixture consists of antimicrobial substances and protease inhibitors for the simultaneous inactivation of a wide range of proteolytic enzymes. It has already been tested in lab-scale, as part of World Anti-Doping Agency's (WADA) funded research project, in terms of efficiency against microbial and proteolytic activity. The present work, funded also by WADA, is a follow-up study on the improvement of chemical stabilization mixture composition, application mode and limitation of interferences, using pilot urine collection containers, spray-coated in their internal surface with the chemical stabilization mixture. Urine in plastic stabilized collection containers have been gone through various incubation cycles to test for stabilization efficiency and analytical matrix interferences by three WADA accredited Laboratories (Athens, Ghent, and Rome). The spray-coated chemical stabilization mixture was tested against microorganism elimination and steroid glucuronide degradation, as well as enzymatic breakdown of proteins, such as intact hCG, recombinant erythropoietin and small peptides (GHRPs, ipamorelin), induced by proteolytic enzymes. Potential analytical interferences, observed in the presence of spray-coated chemical stabilization mixture, were recorded using routine screening procedures. The results of the current study support the application of the spray-coated plastic urine container, in the doping control collection procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Preventive doping control screening analysis of prohibited substances in human urine using rapid-resolution liquid chromatography/high-resolution time-of-flight mass spectrometry.

    PubMed

    Vonaparti, A; Lyris, E; Angelis, Y S; Panderi, I; Koupparis, M; Tsantili-Kakoulidou, A; Peters, R J B; Nielen, M W F; Georgakopoulos, C

    2010-06-15

    Unification of the screening protocols for a wide range of doping agents has become an important issue for doping control laboratories. This study presents the development and validation of a generic liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) screening method of 241 small molecule analytes from various categories of prohibited substances (stimulants, narcotics, diuretics, beta(2)-agonists, beta-blockers, hormone antagonists and modulators, glucocorticosteroids and anabolic agents). It is based on a single-step liquid-liquid extraction of hydrolyzed urine and the use of a rapid-resolution liquid chromatography/high-resolution time-of-flight mass spectrometric system acquiring continuous full scan data. Electrospray ionization in the positive mode was used. Validation parameters consisted of identification capability, limit of detection, specificity, ion suppression, extraction recovery, repeatability and mass accuracy. Detection criteria were established on the basis of retention time reproducibility and mass accuracy. The suitability of the methodology for doping control was demonstrated with positive urine samples. The preventive role of the method was proved by the case where full scan acquisition with accurate mass measurement allowed the retrospective reprocessing of acquired data from past doping control samples for the detection of a designer drug, the stimulant 4-methyl-2-hexanamine, which resulted in re-reporting a number of stored samples as positives for this particular substance, when, initially, they had been reported as negatives. Copyright (c) 2010 John Wiley & Sons, Ltd.

  9. Reliable Quantification of the Potential for Equations Based on Spot Urine Samples to Estimate Population Salt Intake: Protocol for a Systematic Review and Meta-Analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S

    2016-09-21

    Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.

  10. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Agreement between 24-hour salt ingestion and sodium excretion in a controlled environment.

    PubMed

    Lerchl, Kathrin; Rakova, Natalia; Dahlmann, Anke; Rauh, Manfred; Goller, Ulrike; Basner, Mathias; Dinges, David F; Beck, Luis; Agureev, Alexander; Larina, Irina; Baranov, Victor; Morukov, Boris; Eckardt, Kai-Uwe; Vassilieva, Galina; Wabel, Peter; Vienken, Jörg; Kirsch, Karl; Johannes, Bernd; Krannich, Alexander; Luft, Friedrich C; Titze, Jens

    2015-10-01

    Accurately collected 24-hour urine collections are presumed to be valid for estimating salt intake in individuals. We performed 2 independent ultralong-term salt balance studies lasting 105 (4 men) and 205 (6 men) days in 10 men simulating a flight to Mars. We controlled dietary intake of all constituents for months at salt intakes of 12, 9, and 6 g/d and collected all urine. The subjects' daily menus consisted of 27 279 individual servings, of which 83.0% were completely consumed, 16.5% completely rejected, and 0.5% incompletely consumed. Urinary recovery of dietary salt was 92% of recorded intake, indicating long-term steady-state sodium balance in both studies. Even at fixed salt intake, 24-hour urine collection for sodium excretion (UNaV) showed infradian rhythmicity. We defined a ±25 mmol deviation from the average difference between recorded sodium intake and UNaV as the prediction interval to accurately classify a 3-g difference in salt intake. Because of the biological variability in UNaV, only every other daily urine sample correctly classified a 3-g difference in salt intake (49%). By increasing the observations to 3 consecutive 24-hour collections and sodium intakes, classification accuracy improved to 75%. Collecting seven 24-hour urines and sodium intake samples improved classification accuracy to 92%. We conclude that single 24-hour urine collections at intakes ranging from 6 to 12 g salt per day were not suitable to detect a 3-g difference in individual salt intake. Repeated measurements of 24-hour UNaV improve precision. This knowledge could be relevant to patient care and the conduct of intervention trials. © 2015 American Heart Association, Inc.

  12. Mass spectrometric detection of peginesatide in human urine in doping control analysis.

    PubMed

    Möller, Ines; Thomas, Andreas; Delahaut, Philippe; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario

    2012-11-01

    Erythropoiesis-stimulating agents (ESAs) have frequently been confessed to be illicitly used in elite sports due to their endurance enhancing effects. Recently, peginesatide, the first representative of a new generation of ESAs, referred to as Erythropoietin (EPO)-mimetic peptides, obtained approval in the USA under the trade name Omontys(®) for the treatment of anaemic patients. Lacking sequence homology with EPO, it consists of a pegylated homodimeric peptide of approximately 45 kDa, and thus, specific approaches for the determination of peginesatide in blood were developed as conventional detection assays for EPO do not allow for the analysis of the EPO-mimetic peptides. However, as urine specimens are the most frequently provided doping control samples and pharmacokinetic studies conducted in rats and monkeys revealed the excretion of the pegylated peptide into urine, a detection method for peginesatide in urine would be desirable. A mass spectrometric assay in human urine was developed consisting of protein precipitation with acetonitrile followed by proteolytic digestion after the removal of the acetonitrile fraction under reduced pressure. Purification and concentration of the resulting proteotypic target peptide was accomplished by means of solid-phase extraction on strong cation-exchange resin prior to liquid chromatographic-tandem mass spectrometric analysis. Method validation was performed for qualitative purposes and demonstrated specificity, precision, linearity as well as sufficient sensitivity (limit of detection: 0.5 ng/ml) while proof-of-concept for the applicability of the assay for the determination of peginesatide in authentic urine samples was obtained by analyzing animal in vivo specimens collected after a single i.v. administration of peginesatide over a period of 4 days. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Neutrophil Gelatinase-Associated Lipocalin Biomarker and Urinary Tract Infections: A Diagnostic Case-Control Study (NUTI Study).

    PubMed

    Price, Jameca Renee; Guran, Larissa; Lim, Jeong Youn; Megli, Christina J; Clark, Amanda L; Edwards, Sharon Renee; Denman, Mary Anna; Gregory, W Thomas

    Acute uncomplicated urinary tract infection (UTI) in women is often treated based on symptoms alone. Urinary tract infection symptoms are highly sensitive but lack specificity and result in overuse of antibiotics. We sought to determine if urine neutrophil gelatinase-associated lipocalin (uNGAL) levels in urine can accurately discriminate between UTI and healthy women. We recruited adult women aged 18 to 85 years presenting in the ambulatory setting from November 2014 to January 2016. Cases were defined as women with Centers for Disease Control and Prevention-defined UTI symptoms and a positive urine culture of more than 10 organisms/mL on a midstream clean-catch specimen. Women without UTI symptoms were matched by age and menopausal status as control subjects. Exclusion criteria were no UTIs within 8 weeks, urinary tract anomalies, renal disease, pregnancy, or diabetes. Clean-catch urine samples were obtained for measuring uNGAL, prior to antibiotic treatment of cases. We used Mann-Whitney U test to compare the 2 groups. Receiver operating characteristic curves were plotted to compare the performance of uNGAL to established urinary markers. We enrolled 50 UTI cases and 50 control subjects. Urine NGAL levels were higher in the UTI group than in the control subjects (P < 0.0001). Using a cutoff of 23.9 ng/mL, NGAL achieved 98% sensitivity and 100% specificity. The receiver operating characteristic curve had an area under the curve of 0.97 (95% confidence interval, 0.93-1.00), which was significantly high and showed that uNGAL can identify UTI. Urine NGAL has the potential as a biomarker for diagnosing UTIs in adult women.

  14. Comparison between Indirect Immunofluorescence Assay and Shell Vial Culture for Detection of Mumps Virus from Clinical Samples

    PubMed Central

    Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita

    2003-01-01

    We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158

  15. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  16. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  17. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    PubMed

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  18. Primary health care providers surveyed commonly misinterpret 'first void urine' for chlamydia screening.

    PubMed

    Lusk, M Josephine; Uddin, Ruby; Ferson, Mark; Rawlinson, William; Konecny, Pam

    2009-03-01

    An open question survey of general practitioners (GP) and hospital emergency department (ED) doctors revealed that the term 'FVU' (first void urine) used for urine chlamydia testing, is ambiguous, potentially leading to incorrect urine sample collection and barriers to effective screening. The results of this survey indicate that only 4.3% (95% confidence interval [CI] 0.5-14.5%) of GP and 6.9% (95% CI 0.9-22.8%) of ED doctors respectively, correctly interpreted the meaning of FVU. The majority of clinicians surveyed misunderstood 'FVU' to require the first urine void of the day, accounting for 68.1% (95% CI 52.9-80.9%) of GP responses and 37.9% (95% CI 20.7-57.7%) of ED doctors responses. This highlights the need for clarification and standardisation of terminology used in urine chlamydia screening for health care providers, in order to optimise strategies for diagnosis and control of the ongoing chlamydia epidemic.

  19. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  20. Detection of the diuretic hydrochlorothiazide in a doping control urine sample as the result of a non-steroidal anti-inflammatory drug (NSAID) tablet contamination.

    PubMed

    Helmlin, Hans-Jörg; Mürner, André; Steiner, Samuel; Kamber, Matthias; Weber, Christina; Geyer, Hans; Guddat, Sven; Schänzer, Wilhelm; Thevis, Mario

    2016-10-01

    Hydrochlorothiazide (HCTZ, 6-chloro-3,4-dihydro-2H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide) belongs to the class of diuretic agents that represent one of today's cornerstones of the treatment of hypertensive patients. In addition to its clinical relevance, HCTZ is prohibited in sports according to the regulations of the World Anti-Doping Agency (WADA) at all times and has frequently been detected in sports drug testing urine samples worldwide since its ban was introduced in 1988. Despite these facts, the adverse analytical finding concerning HCTZ in an in-competition routine doping control sample collected in December 2014 was further investigated, particularly motivated by the comparably low urinary concentration of the drug accounting for approximately 5ng/mL. The athlete in question did not declare the use of any nutritional supplement or medication other than the ingestion of a non-steroidal anti-inflammatory drug (NSAID) prior to competition. Hence, the drug (formulated as coated tablet) provided by the athlete as well as the corresponding retention sample of the manufacturer were analyzed. Noteworthy, both samples confirmed the presence of about 2μg of HCTZ per tablet. In order to further probe for the plausibility of the observed urinary HCTZ concentrations with the scenario of drug ingestion and subsequent doping control sample collection, administration studies with produced HCTZ-spiked placebo-tablets (2.5μg of HCTZ/tablet) were conducted. Urine specimens were collected prior to and after ingestion of the drug and subjected to routine doping control analytical procedures employing liquid chromatography/tandem mass spectrometry. While blank urine samples returned negative test results, post-administration specimens were found to contain HCTZ at concentrations of approximately 1-16ng/mL, which supported the athlete's inadvertent intake of HCTZ via contaminated NSAID tablets. Due to the substantial sensitivity of test methods employed today by doping control laboratories, even drug contaminations ranging within the good manufacturing practice (GMP) limit of 10ppm overall carry-over can evidently lead to adverse analytical findings. This calls into question whether selected (classes of) substances such as diuretics should be reported only when exceeding a defined reporting level and/or whether adverse analytical findings of non-threshold substances should be reported with an estimated semi-quantitative concentration of the identified substance to facilitate the result management by anti-doping organizations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Normalization to specific gravity prior to analysis improves information recovery from high resolution mass spectrometry metabolomic profiles of human urine.

    PubMed

    Edmands, William M B; Ferrari, Pietro; Scalbert, Augustin

    2014-11-04

    Extraction of meaningful biological information from urinary metabolomic profiles obtained by liquid-chromatography coupled to mass spectrometry (MS) necessitates the control of unwanted sources of variability associated with large differences in urine sample concentrations. Different methods of normalization either before analysis (preacquisition normalization) through dilution of urine samples to the lowest specific gravity measured by refractometry, or after analysis (postacquisition normalization) to urine volume, specific gravity and median fold change are compared for their capacity to recover lead metabolites for a potential future use as dietary biomarkers. Twenty-four urine samples of 19 subjects from the European Prospective Investigation into Cancer and nutrition (EPIC) cohort were selected based on their high and low/nonconsumption of six polyphenol-rich foods as assessed with a 24 h dietary recall. MS features selected on the basis of minimum discriminant selection criteria were related to each dietary item by means of orthogonal partial least-squares discriminant analysis models. Normalization methods ranked in the following decreasing order when comparing the number of total discriminant MS features recovered to that obtained in the absence of normalization: preacquisition normalization to specific gravity (4.2-fold), postacquisition normalization to specific gravity (2.3-fold), postacquisition median fold change normalization (1.8-fold increase), postacquisition normalization to urinary volume (0.79-fold). A preventative preacquisition normalization based on urine specific gravity was found to be superior to all curative postacquisition normalization methods tested for discovery of MS features discriminant of dietary intake in these urinary metabolomic datasets.

  2. Identification of Potential Biomarkers for Urine Metabolomics of Polycystic Ovary Syndrome Based on Gas Chromatography-Mass Spectrometry.

    PubMed

    Zou, Ying; Zhu, Fu-Fan; Fang, Chao-Ying; Xiong, Xi-Yue; Li, Hong-Yun

    2018-04-20

    Polycystic ovary syndrome (PCOS) is a complex endocrine and metabolic disorder, and it's diagnosis is difficult. The aim of this study was to investigate the metabolic profiles of PCOS patients by analyzing urine samples and identify useful biomarkers for diagnosis of PCOS. This study was carried out in the Department of Obstetrics and Gynecology of the Maternal and Child Health Hospital of Hunan Province from December 2014 to July 2016. In this study, the urine samples of 21 women with PCOS and 16 healthy controls were assessed through gas chromatography-mass spectrometry to investigate the urine metabolite characteristics of PCOS and identify useful biomarkers for the diagnosis of this disorder. The Student's t-test and rank sum test were applied to validate the statistical significance of the between the two groups. In total, 35 urine metabolites were found to be significantly different between the PCOS patients and the controls. In particular, a significant increase in the levels of lactose (10.01 [0,13.99] mmol/mol creatinine vs. 2.35 [0.16, 3.26] mmol/mol creatinine, P = 0.042), stearic acid (2.35 [1.47, 3.14] mmol/mol creatinine vs. 0.05 [0, 0.14] mmol/mol creatinine, P < 0.001), and palmitic acid (2.13 [1.07, 2.79] mmol/mol creatinine vs. 0 [0, 0] mmol/mol creatinine, P < 0.001) and a decrease in the levels of succinic acid (0 [0, 0] mmol/mol creatinine vs. 38.94 [4.16, 51.30] mmol/mol creatinine, P < 0.001) were found in the PCOS patients compared with the controls. It was possible to cluster the PCOS patients and the healthy controls into two distinct regions based on a principal component analysis model. Of the differentially expressed metabolites, four compounds, including stearic acid, palmitic acid, benzoylglycine, and threonine, were selected as potential biomarkers. This study offers new insight into the pathogenesis of PCOS, and the discriminating urine metabolites may provide a prospect for the diagnosis of PCOS.

  3. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  4. Urine stability and steroid profile: towards a screening index of urine sample degradation for anti-doping purpose.

    PubMed

    Mazzarino, Monica; Abate, Maria Gabriella; Alocci, Roberto; Rossi, Francesca; Stinchelli, Raffaella; Molaioni, Francesco; de la Torre, Xavier; Botrè, Francesco

    2011-01-10

    The presence of microorganisms in urine samples, under favourable conditions of storage and transportation, may alter the concentration of steroid hormones, thus altering the correct evaluation of the urinary steroid profile in doping control analysis. According to the rules of the World Anti-Doping Agency (WADA technical document TD2004 EAAS), a testosterone deconjugation higher than 5% and the presence of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the deconjugated fraction, are reliable indicators of urine degradation. The determination of these markers would require an additional quantitative analysis since the steroids screening analysis, in anti-doping laboratories, is performed in the total (free+conjugated) fraction. The aim of this work is therefore to establish reliable threshold values for some representative compounds (namely 5α-androstane-3,17-dione and 5β-androstane-3,17-dione) in the total fraction in order to predict directly at the screening stage the potential microbial degradation of the urine samples. Preliminary evidence on the most suitable degradation indexes has been obtained by measuring the urinary concentration of testosterone, epitestosterone, 5α-androstane-3,17-dione and 5β-androstane-3,17-dione by gas chromatography-mass spectrometric every day for 15 days in the deconjugated, glucuronide and total fraction of 10 pools of urines from 60 healthy subjects, stored under different pH and temperature conditions, and isolating the samples with one or more markers of degradation according to the WADA technical document TD2004EAAS. The threshold values for 5α-androstane-3,17-dione and 5β-androstane-3,17-dione were therefore obtained correlating the testosterone deconjugation rate with the urinary concentrations of 5α-androstane-3,17-dione and 5β-androstane-3,17-dione in the total fraction. The threshold values suggested as indexes of urine degradation in the total fraction were: 10 ng mL(-1) for 5α-androstane-3,17-dione and 20 ng mL(-1) for 5β-androstane-3,17-dione. The validity of this approach was confirmed by the analysis of routine samples for more than five months (i.e. on a total of more than 4000 urine samples): samples with a concentration of total 5α-androstane-3,17-dione and 5β-androstane-3,17-dione higher than the threshold values showed a percentage of free testosterone higher than 5 of its total amount; whereas free testosterone in a percentage higher than 5 of its total amount was not detected in urines with a concentration of total 5α-androstane-3,17-dione and 5β-androstane-3,17-dione lower than the threshold values. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. A reinforcement-based therapeutic workplace for the treatment of drug abuse: three-year abstinence outcomes.

    PubMed

    Silverman, Kenneth; Svikis, Dace; Wong, Conrad J; Hampton, Jacqueline; Stitzer, Maxine L; Bigelow, George E

    2002-08-01

    Long-term Therapeutic Workplace effects were evaluated in heroin- and cocaine-dependent, unemployed, treatment-resistant young mothers. Participants were paid to work or to train in the Therapeutic Workplace but had to provide drug-free urine samples to gain daily access. Participants (N = 40) were randomly assigned to a Therapeutic Workplace or usual care control group. Therapeutic Workplace participants could work for 3 years. Relative to controls, Therapeutic Workplace participants increased cocaine (28% vs. 54% negative; p = .04) and opiate (37% vs. 60% negative; p = .05) abstinence on the basis of monthly urine samples collected until 3 years after intake. The Therapeutic Workplace can be an effective long-term treatment of cocaine and heroin addiction in poor and chronically unemployed young mothers.

  6. Prevalence of urinary tract infection (UTI) in sequential acutely unwell children presenting in primary care: exploratory study.

    PubMed

    O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2011-03-01

    Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.

  7. Critical study of common conditions of storage of glucocorticoids and catecholamines in 24-h urine collected during resting and exercising conditions.

    PubMed

    Gouarne, C; Foury, A; Duclos, M

    2004-10-01

    Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.

  8. Identification of a three-biomarker panel in urine for early detection of pancreatic adenocarcinoma

    PubMed Central

    Radon, Tomasz P; Massat, Nathalie J; Jones, Richard; Alrawashdeh, Wasfi; Dumartin, Laurent; Ennis, Darren; Duffy, Stephen W; Kocher, Hemant M; Pereira, Stephen P; Nascimento, Cristiane M; Real, Francisco X; Malats, Núria; Neoptolemos, John; Costello, Eithne; Greenhalf, William; Lemoine, Nick R; Crnogorac-Jurcevic, Tatjana

    2015-01-01

    Purpose Non-invasive biomarkers for early detection of pancreatic ductal adenocarcinoma (PDAC) are currently not available. Here, we aimed to identify a set of urine proteins able to distinguish patients with early stage PDAC from healthy individuals (H). Experimental design Proteomes of 18 urine samples from healthy controls, chronic pancreatitis and PDAC patients (six/group) were assayed using GeLC/MS/MS analysis. The selected biomarkers were subsequently validated using ELISA assays using multiple logistic regression applied to a training dataset in a multicentre cohort comprising 488 urine samples. Results LYVE-1, REG1A and TFF1 were selected as candidate biomarkers. When comparing PDAC (n=192) to healthy (n=87) urines, the resulting areas under the receiver operating characteristic curves (AUCs) of the panel were 0.89 (95%CI 0.84-0.94) in the training (70% of the data), and 0.92 (95%CI 0.86-0.98) in the validation (30% of the data) datasets. When comparing PDAC stage I-II (n=71) to healthy urines, the panel achieved AUCs of 0.90 (95%CI 0.84-0.96) and 0.93 (95%CI 0.84-1.00) in the training and validation datasets, respectively. In PDAC stage I-II and healthy samples with matching plasma CA19.9 the panel achieved a higher AUC of 0.97 (95%CI 0.94-0.99) than CA19.9 (AUC=0.88, 95%CI 0.81-0.95, p=0.005). Adding plasma CA19.9 to the panel increased the AUC from 0.97 (95%CI 0.94-0.99) to 0.99 (95%CI 0.97-1.00, p=0.04) but did not improve the comparison of stage I-IIA PDAC (n=17) to healthy urine. Conclusion We have established a novel, three-protein biomarker panel that is able to detect patients with early stage pancreatic cancer in urine specimens. PMID:26240291

  9. Acute, Five- and Ten-Day Inhalation Study of Hydroprocessed Esters and Fatty Acids-Mixed Fats (HEFA-F) Jet Fuel

    DTIC Science & Technology

    2012-09-01

    Groups ...................18 Table 6. Urine Specific Gravity in the Ten-Day Duration Groups ...............................................19 Table 7...exposed rats were not consistently significant compared to control groups and were considered random due to small group sizes. In urine samples...sources. Alternative fuels may be developed by synthesis from simpler molecules (e.g., natural gas) or by refining from non-petroleum sources (e.g

  10. Efficacy of New Low-Cost Filtration Device for Recovering Schistosoma haematobium Eggs from Urine

    PubMed Central

    Gyorkos, Theresa W.; Ramsan, Mahdi; Foum, Ali; Khamis, Iddi Simba

    2001-01-01

    A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs. PMID:11427595

  11. Long-Term Frozen Storage of Urine Samples: A Trouble to Get PCR Results in Schistosoma spp. DNA Detection?

    PubMed Central

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Background Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods. Methodology/Principal Findings We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Conclusions/Significance Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used. PMID:23613907

  12. Investigations of the microbial transformation of cortisol to prednisolone in urine samples.

    PubMed

    Bredehöft, Michael; Baginski, Rainer; Parr, Maria-Kristina; Thevis, Mario; Schänzer, Wilhelm

    2012-03-01

    Doping control samples are normally collected under non-sterile conditions and sometimes, storage and transportation are influenced by parameters such as the temperature. Therefore, microbial contamination and subsequent alteration of a sample's composition are possible. Studies regarding sample collection in cattle breeding have already shown enzymatic transformation of endogenous testosterone to boldenone causing false-positive findings. The aim of the present study was to investigate whether positive doping cases with the synthetic corticosteroids prednisolone and prednisone may result from microbial transformation of the endogenous corticosteroids cortisol and cortisone, respectively. A method comprising parameters such as pH values and screening results for synthetic glucocorticosteroids as well as incubation experiments followed by liquid chromatographic and mass spectrometric analysis was employed to test for contaminating germs with Δ(1)-dehydrogenase activity. Over 700 urine samples comprising inpatient and doping control specimens were investigated. In none of them, 1,2-dehydrogenating activity was confirmed. These findings are in accordance with other studies. However, the problem of microbial alteration of doping control specimens with special respect to 1,2-dehydrogenation must not be underestimated. Article from a special issue on steroids and microorganisms. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection.

    PubMed

    Rosales-Conrado, N; León-González, M E; Pérez-Arribas, L V; Polo-Díez, L M

    2008-01-01

    Chlorophenoxy acid herbicides are intensively applied to get rid of unwanted plants because of their low cost and selectivity. Due to their toxicity, which depends on their chemical form, the European Community has established legal directives to restrict their use and to control their maximum residue levels in several matrices. Determination of chlorophenoxy acids-2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy)propanoic acid (2,4-DP), 2-(4-chloro-2-methylphenoxy)propanoic acid (MCPP), 4-(4-chloro-2-methylphenoxy)butanoic acid (MCPB) and 2-(2,4,5-trichlorophenoxy)propanoic acid (2,4,5-TP) in spiked human urine samples has been carried out by capillary LC, after solid-phase extraction on a column packed with silica C18 restricted-access material. Chromatographic analysis was performed in gradient-elution mode at 25 degrees C, with injection of 20 microL low-organic-solvent composition herbicide solutions for focusing purposes on the head of the capillary column, and diode array detection at 232 nm. Urine samples collected during 24 h from healthy and unexposed volunteers were spiked in the concentration range 25-150 microg L(-1); recoveries obtained were between 66 and 100% (n = 6 for each spiked level) and RSDs (relative standard deviations) were between 1 and 5%. Detection limits in the urine samples from volunteers were between 3.5 and 6.0 microg L(-1). The developed methodology has allowed the clean-up and preconcentration of low volumes of untreated human urine without previous treatment, showing the effectiveness of the employed SPE sorbent for extracting the target analytes and ultimately resulting in the reduction of the sample-preparation time.

  14. Use of ferric chloride to identify salicylate-containing poisons.

    PubMed

    Hoffman, Robert J; Nelson, Lewis S; Hoffman, Robert S

    2002-01-01

    Ferric chloride (FeCl3) is used to qualitatively test the urine of patients with presumed salicylate exposure. FeCl3 testing of an unidentified poison might provide evidence of salicylate exposure in situations where FeCl3 urine testing cannot be used. Such situations include the absence of a urine sample, immediately after ingestion before urine contains a detectable quantity of salicylate, or for patients chronically using salicylatesfor which FeCl3 testing is unhelpful. This study seeks to determine if FeCl3 can be used to identify salicylate-containing products. We assessed the reactivity of FeCl3 with commercially available salicylate-containing products. We applied 0.1 mL of 10% FeCl3 solution to each of 15 various salicylate-containing products including: regular and buffered acetylsalicylic acid, bismuth subsalicylate, methylsalicylate, physostigmine salicylate, salicylic acid, trolamine salicylate, and herbal tablets with salicin-containing white willow bark (Salix sp.). These products tested were: regular and enteric-coatedpills (n = 4), powder (n = 1), topical creams (n = 5), topical liquids (n = 4), and intravenous solution (n = 1). FeCl3 was applied to crushed tablets and added directly to liquids and creams. Fifteen salicylate-free controls including liquids, pills, and creams similar in appearance to experimental samples were also tested. Three blinded physiciansfamiliar with FeCl3 testing independently observed the addition of FeCl3 to each sample and rated a positive or negative result. All salicylate-containing products were interpreted to be clearly FeCl3 positive and all control samples were interpreted to be clearly FeCl3 negative. Salicylate-containing products may be identified using FeCl33. When using FeCl3

  15. URINARY MUTAGENICITY AND COLORECTAL ADENOMA RISK

    EPA Science Inventory

    Abstract

    We investigated urinary mutagenicity and colorectal adenoma risk in a clinic-based, case-control study of currently nonsmoking cases (n = 143) and controls (n = 156). Urinary organics were extracted by C18/methanol from 12-h overnight urine samples, and mutagenici...

  16. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  17. The effect of substrate composition and storage time on urine specific gravity in dogs.

    PubMed

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  18. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...

  19. Consideration of the degree of increase in urine metadrenalines provides superior specificity in the diagnosis of phaeochromocytoma than additional urine catecholamine measurement.

    PubMed

    Scargill, J J; Reed, P; Kane, J

    2013-01-01

    Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.

  20. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    PubMed

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  1. Total Extracellular Small RNA Profiles from Plasma, Saliva, and Urine of Healthy Subjects

    PubMed Central

    Yeri, Ashish; Courtright, Amanda; Reiman, Rebecca; Carlson, Elizabeth; Beecroft, Taylor; Janss, Alex; Siniard, Ashley; Richholt, Ryan; Balak, Chris; Rozowsky, Joel; Kitchen, Robert; Hutchins, Elizabeth; Winarta, Joseph; McCoy, Roger; Anastasi, Matthew; Kim, Seungchan; Huentelman, Matthew; Van Keuren-Jensen, Kendall

    2017-01-01

    Interest in circulating RNAs for monitoring and diagnosing human health has grown significantly. There are few datasets describing baseline expression levels for total cell-free circulating RNA from healthy control subjects. In this study, total extracellular RNA (exRNA) was isolated and sequenced from 183 plasma samples, 204 urine samples and 46 saliva samples from 55 male college athletes ages 18–25 years. Many participants provided more than one sample, allowing us to investigate variability in an individual’s exRNA expression levels over time. Here we provide a systematic analysis of small exRNAs present in each biofluid, as well as an analysis of exogenous RNAs. The small RNA profile of each biofluid is distinct. We find that a large number of RNA fragments in plasma (63%) and urine (54%) have sequences that are assigned to YRNA and tRNA fragments respectively. Surprisingly, while many miRNAs can be detected, there are few miRNAs that are consistently detected in all samples from a single biofluid, and profiles of miRNA are different for each biofluid. Not unexpectedly, saliva samples have high levels of exogenous sequence that can be traced to bacteria. These data significantly contribute to the current number of sequenced exRNA samples from normal healthy individuals. PMID:28303895

  2. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  3. [Collective scombroid fish poisoning following tuna consumption in Castellon].

    PubMed

    Arnedo Pena, A; Bellido Blasco, J B; Pac Sa, M R; González Morán, F; Criado Juárez, J; Mesanza del Notario, I; Rodríguez Merquero, N; Balagué López, A

    1996-11-16

    To investigate and control of a collective scombroid-fish poisoning (SFP) outbreak, that took place in Castellón, Spain. Description of the outbreak and case-control study in order to identify risk factors. Active surveillance of SFP cases, and inspection of implicated markets. Histamine determination in urine of cases and foods. During June 1994, 15 cases of SFP were found out, with 12 cases occurred on June, 28 and 29. Five families were affected (attack rate 68.2%). The median incubation period was 45 minutes. Disease symptoms included facial or general flushing, headache, diarrhea, nausea, abdominal pain, and peppery taste. Implicated food was fresh tuna, bought in a hypermarket of Castellón (odds ratio = 26.4, 95% confidence intervals: 1.05-666.8), adjusted by age and sex using logistic regression analysis. Four samples of urine from cases presented histamine concentration above 35 micrograms/l. Three samples of tuna consumed by cases and one sample of tuna from the hypermarket had histamine concentration above a 200 ppm. Considering the situation of risk, remaining suspected tuna was confiscated from the hypermarket. Rest unknown if the descompositions of tuna occurred in the hypermarket or during capture and distribution. SFP was caused by fresh tuna ingestion with epidemiologic and analytic confirmation. Determination of histamine in urine of patients could permit to confirm SFP.

  4. Validation of a sensitive LC-MS assay for quantification of glyburide and its metabolite 4-transhydroxy glyburide in plasma and urine: an OPRU Network study

    PubMed Central

    Naraharisetti, Suresh Babu; Kirby, Brian J.; Hebert, Mary F.; Easterling, Thomas R.; Unadkat, Jashvant D.

    2009-01-01

    Glyburide (glibenclamide, INN), a second generation sulfonylurea is widely used in the treatment of gestational diabetes mellitus (GDM). None of the previously reported analytical methods provide adequate sensitivity for the expected sub-nanogram/mL maternal and umbilical cord plasma concentrations of glyburide during pregnancy. We developed and validated a sensitive and low sample volume liquid chromatographic-mass spectrometric (LC-MS) method for simultaneous determination of glyburide (GLY) and its metabolite, 4-transhydroxy glyburide (M1) in human plasma (0.5 ml) or urine (0.1 ml). The limits of quantitation (LOQ) for GLY and M1 in plasma were 0.25 and 0.40 ng/mL, respectively whereas it was 1.06 ng/mL for M1 in urine. As measured by quality control samples, precision (% coefficient of variation) of the assay was < 15% whereas the accuracy (% deviation from expected) ranged from −10.1–14.3%. We found that the GLY metabolite, M1 is excreted in the urine as the glucuronide-conjugate. PMID:17980680

  5. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study

    PubMed Central

    Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard

    2018-01-01

    Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136

  6. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study.

    PubMed

    Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard

    2018-01-01

    To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.

  7. Trace Chemical Analysis Methodology

    DTIC Science & Technology

    1980-04-01

    oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine

  8. In vitro synthesis and characterisation of three fenoterol sulfoconjugates detected in fenoterol post-administration urine samples.

    PubMed

    Orlovius, A K; Guddat, S; Gütschow, M; Thevis, M; Schänzer, W

    2013-11-01

    Fenoterol, a fast-acting β2-adrenergic agonist, is used in the therapy of obstructive pulmonary diseases and for the inhibition of premature labour obstetrics. Doping control for β2-agonists, which are prohibited in sports by the World Anti-Doping Agency, is commonly performed by liquid chromatography/mass spectrometry after hydrolysis of phase II metabolites. The continuing development of analytical procedures has led to direct injection of urine samples without sample preparation becoming a viable tool. For the detection of substances without sample preparation, including hydrolysis, detailed information of the phase II metabolism of the substances is essential. In this study, human S9 fractions of different tissues and two recombinant sulfotransferases were investigated for their potential to form fenoterol sulfoconjugates, which were characterised in detail. Two mono-sulfoconjugates and one bis-sulfoconjugate were synthesised and their structures confirmed by liquid chromatography–high-resolution/high-accuracy mass spectrometry. All of the metabolites were identified as esterified phenolic compounds. Excretion studies with orally and inhalatively administered fenoterol proved the occurrence of the sulfoconjugates in vivo. Inhalatively administered fenoterol resulted in the detection of the two monosulfoconjugates in low amounts in urine due to the lower inhalation dose of fenoterol compared to the oral dose. After oral uptake of fenoterol, the two mono-sulfoconjugates and a fenoterol bis-sulfoconjugate were detected in urine. This is the first report of the bis-sulfoconjugate.

  9. [Decreased beta-phenylethylamine in urine of children with attention deficit hyperactivity disorder and autistic disorder].

    PubMed

    Kusaga, Akira

    2002-05-01

    beta-phenylethylamine (PEA), a biogenic trace amine, acts as a neuromodulator in the nigrostriatal dopaminergic pathway and stimulates the release of dopamine. To clarify the mechanism of neurochemical metabolism in attention deficit hyperactivity disorder (ADHD), we measured the urine levels of PEA using gas chromatography-chemical ionization-mass spectrometry. The urinary levels of 3-methoxy-4-hydroxyphenyl glycol (MHPG), homovanillic acid (HVA), and 5-hydroxy-indoleacetic acid (5-HIAA) were determined by high performance liquid chromatography. Urine samples were collected in a 24 hour period. Findings were compared with those obtained from controls (N = 15), children with ADHD (N = 15), and children with autistic disorder (AD) (N = 5). The mean urinary levels of MHPG, HVA, and 5-HIAA in the children with ADHD were not significantly different from those of the controls or those with AD, whereas PEA levels were significantly lower in children with ADHD (11.23 +/- 13.40 micrograms/g creatinine) compared with controls (56.01 +/- 52.18 micrograms/g creatinine). PEA and MHPG levels in children with AD (14.75 +/- 14.37 micrograms/g creatine, 1.10 +/- 0.61 micrograms/mg creatine, respectively) were significantly decreased compared to controls (MHPG, 2.2 +/- 0.9 micrograms/mg creatine). The decreased urine PEA in children with ADHD and AD may suggest a common underlying pathophysiology. The decreased urine MHPG in children with AD might indicate the existence of an alteration in central and peripheral noradrenergic function.

  10. Effects of processing delay, temperature, and transport tube type on results of quantitative bacterial culture of canine urine.

    PubMed

    Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D

    2016-01-15

    To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.

  11. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.

    PubMed

    García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime

    2017-06-01

    Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.

  12. Determination of Vasopressin and Desmopressin in urine by means of liquid chromatography coupled to quadrupole time-of-flight mass spectrometry for doping control purposes.

    PubMed

    Thomas, A; Solymos, E; Schänzer, W; Baume, N; Saugy, M; Dellanna, F; Thevis, M

    2011-11-30

    The anti-diuretic neurohypophysial hormone Vasopressin (Vp) and its synthetic analogue Desmopressin (Dp, 1-desamino-vasopressin) have received considerable attention from doping control authorities due to their impact on physiological blood parameters. Accordingly, the illicit use of Desmopressin in elite sport is sanctioned by the World Anti-Doping Agency (WADA) and the drug is classified as masking agent. Vp and Dp are small (8-9 amino acids) peptides administered orally as well as intranasally. Within the present study a method to determine Dp and Vp in urinary doping control samples by means of liquid chromatography coupled to quadrupole high resolution time-of-flight mass spectrometry was developed. After addition of Lys-Vasopressin as internal standard and efficient sample clean up with a mixed mode solid phase extraction (weak cation exchange), the samples were directly injected into the LC-MS system. The method was validated considering the parameters specificity, linearity, recovery (80-100%), accuracy, robustness, limit of detection/quantification (20/50 pg mL(-1)), precision (inter/intra-day<10%), ion suppression and stability. The analysis of administration study urine samples collected after a single intranasal or oral application of Dp yielded in detection windows for the unchanged target analyte for up to 20 h at concentrations between 50 and 600 pg mL(-1). Endogenous Vp was detected in concentrations of approximately 20-200 pg mL(-1) in spontaneous urine samples obtained from healthy volunteers. The general requirements of the developed method provide the characteristics for an easy transfer to other anti-doping laboratories and support closing another potential gap for cheating athletes. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Quantification of urinary AICAR concentrations as a matter of doping controls.

    PubMed

    Thomas, Andreas; Beuck, Simon; Eickhoff, Jens Christian; Guddat, Sven; Krug, Oliver; Kamber, Matthias; Schänzer, Wilhelm; Thevis, Mario

    2010-04-01

    Influencing the endurance in elite sports is one of the key points in modern sports science. Recently, a new class of prohibited substances reached in the focus of doping control laboratories and their misuse was classified as gene doping. The adenosine monophosphate activated protein kinase activator 5-amino-4-imidazolecarboxyamide ribonucleoside (AICAR) was found to significantly enhance the endurance even in sedentary mice after treatment. Due to endogenous production of AICAR in healthy humans, considerable amounts were present in the circulation and, thus, were excreted into urine. Considering these facts, the present study was initiated to fix reference values of renally cleared AICAR in elite athletes. Therefore a quantitative analytical method by means of isotope-dilution liquid chromatography (analytical column: C6-phenyl) coupled to tandem mass spectrometry, after a sample preparation consisting of a gentle dilution of native urine, was developed. Doping control samples of 499 athletes were analysed, and AICAR concentrations in urine were determined. The mean AICAR value for all samples was 2,186 ng/mL with a standard deviation of 1,655 ng/mL. Concentrations were found to differ depending on gender, type of sport and type of sample collection (in competition/out of competition). The method was fully validated for quantitative purposes considering the parameters linearity, inter- (12%, 7% and 10%) and intraday precision (14%, 9% and 12%) at low, mid and high concentration, robustness, accuracy (approx. 100%), limit of quantification (100 ng/mL), stability and ion suppression effects, employing an in-house synthesised (13)C(5)-labelled AICAR as internal standard.

  14. Ghrelin O-acyltransferase (GOAT) enzyme is overexpressed in prostate cancer, and its levels are associated with patient's metabolic status: Potential value as a non-invasive biomarker.

    PubMed

    Hormaechea-Agulla, Daniel; Gómez-Gómez, Enrique; Ibáñez-Costa, Alejandro; Carrasco-Valiente, Julia; Rivero-Cortés, Esther; L-López, Fernando; Pedraza-Arevalo, Sergio; Valero-Rosa, José; Sánchez-Sánchez, Rafael; Ortega-Salas, Rosa; Moreno, María M; Gahete, Manuel D; López-Miranda, José; Requena, María J; Castaño, Justo P; Luque, Raúl M

    2016-12-01

    Ghrelin-O-acyltransferase (GOAT) is the key enzyme regulating ghrelin activity, and has been proposed as a potential therapeutic target for obesity/diabetes and as a biomarker in some endocrine-related cancers. However, GOAT presence and putative role in prostate-cancer (PCa) is largely unknown. Here, we demonstrate, for the first time, that GOAT is overexpressed (mRNA/protein-level) in prostatic tissues (n = 52) and plasma/urine-samples (n = 85) of PCa-patients, compared with matched controls [healthy prostate tissues (n = 12) and plasma/urine-samples from BMI-matched controls (n = 28), respectively]. Interestingly, GOAT levels in PCa-patients correlated with aggressiveness and metabolic conditions (i.e. diabetes). Actually, GOAT expression was regulated by metabolic inputs (i.e. In1-ghrelin, insulin/IGF-I) in cultured normal prostate cells and PCa-cell lines. Importantly, ROC-curve analysis unveiled a valuable diagnostic potential for GOAT to discriminate PCa at the tissue/plasma/urine-level with high sensitivity/specificity, particularly in non-diabetic individuals. Moreover, we discovered that GOAT is secreted by PCa-cells, and that its levels are higher in urine samples from a stimulated post-massage vs. pre-massage prostate-test. In conclusion, plasmatic GOAT levels exhibit high specificity/sensitivity to predict PCa-presence compared with other PCa-biomarkers, especially in non-diabetic individuals, suggesting that GOAT holds potential as a novel non-invasive PCa-biomarker. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    PubMed

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Comprehensive solid-phase extraction of multitudinous bioactive peptides from equine plasma and urine for doping detection.

    PubMed

    Guan, Fuyu; Robinson, Mary A

    2017-09-08

    The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be retrospectively analyzed for peptides unknown at the time of sample analysis. It is the first generic analytical method for comprehensive detection of multitudinous exogenous peptides in biological samples, to the authors' knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    PubMed

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Increased intestinal macromolecular permeability and urine nitrite excretion associated with liver cirrhosis with ascites.

    PubMed

    Lee, Soong; Son, Seung-Cheol; Han, Moon-Jong; Kim, Woo-Jin; Kim, Soo-Hyun; Kim, Hye-Ran; Jeon, Woo-Kyu; Park, Ki-Hong; Shin, Myung-Geun

    2008-06-28

    To determine intestinal permeability, the serum tumor necrosis factor (TNF)-alpha level and urine nitric oxide (NO) metabolites are altered in liver cirrhosis (LC) with or without ascites. Fifty-three patients with LC and 26 healthy control subjects were enrolled in the study. The intestinal permeability value is expressed as the percentage of polyethylene glycol (PEG) 400 and 3350 retrieval in 8-h urine samples as determined by high performance liquid chromatography. Serum TNF-alpha concentrations and urine NO metabolites were determined using an enzyme-linked immunosorbent assay (ELISA) and Greiss reaction method, respectively. The intestinal permeability index was significantly higher in patients with LC with ascites than in healthy control subjects or patients with LC without ascites (0.88 +/- 0.12 vs 0.52 +/- 0.05 or 0.53 +/- 0.03, P < 0.05) and correlated with urine nitrite excretion (r = 0.98). Interestingly, the serum TNF-alpha concentration was significantly higher in LC without ascites than in control subjects or in LC with ascites (198.9 +/- 55.8 pg/mL vs 40.9 +/- 12.3 pg/mL or 32.1 +/- 13.3 pg/mL, P < 0.05). Urine nitrite excretion was significantly higher in LC with ascites than in the control subjects or in LC without ascites (1170.9 +/- 28.7 micromol/L vs 903.1 +/- 55.1 micromol/L or 956.7 +/- 47.7 micromol/L, P < 0.05). Increased intestinal macromolecular permeability and NO is probably of importance in the pathophysiology and progression of LC with ascites, but the serum TNF-alpha concentration was not related to LC with ascites.

  20. Preliminary Application of WCX Magnetic Bead-Based Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry in Analyzing the Urine of Renal Clear Cell Carcinoma.

    PubMed

    Dong, De-Xin; Ji, Zhi-Gang; Li, Han-Zhong; Yan, Wei-Gang; Zhang, Yu-Shi

    2017-12-30

    Objective To evaluate the application of weak cation exchange (WCX) magnetic bead-based Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) in detecting differentially expressed proteins in the urine of renal clear cell carcinoma (RCCC) and its value in the early diagnosis of RCCC.Methods Eleven newly diagnosed patients (10 males and 1 female, aged 46-78, mean 63 years) of renal clear cell carcinoma by biopsy and 10 healthy volunteers (all males, aged 25-32, mean 29.7 years) were enrolled in this study. Urine samples of the RCCC patients and healthy controls were collected in the morning. Weak cation exchange (WCX) bead-based MALDI-TOF MS technique was applied in detecting differential protein peaks in the urine of RCCC. ClinProTools2.2 software was utilized to determine the characteristic proteins in the urine of RCCC patients for the predictive model of RCCC. Results The technique identified 160 protein peaks in the urine that were different between RCCC patients and health controls; and among them, there was one peak (molecular weight of 2221.71 Da) with statistical significance (P=0.0304). With genetic algorithms and the support vector machine, we screened out 13 characteristic protein peaks for the predictive model. Conclusions The application of WCX magnetic bead-based MALDI-TOF MS in detecting differentially expressed proteins in urine may have potential value for the early diagnosis of RCCC.

  1. A validated solid-phase extraction HPLC method for the simultaneous determination of the citrus flavanone aglycones hesperetin and naringenin in urine.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-09-21

    A simple, specific, precise, accurate, and robust HPLC assay for the simultaneous analysis of hesperetin and naringenin in human urine was developed and validated. Urine samples were incubated with beta-glucuronidase/sulphatase and the analytes were isolated by solid-phase extraction using C18 cartridges and separated on a C8 reversed phase column using a mixture of methanol/water/acetic acid (40:58:2, v/v/v) at 45 degrees C. The method was found to be linear in the 50-1200 ng/ml concentration range for both hesperetin and naringenin (r > 0.999). The accuracy of the method was greater than 94.8%, while the intra- and inter-day precision for hesperetin was better than 4.9 and 8.2%, respectively and for naringenin was better than 5.3 and 7.8%, respectively. Recovery for hesperetin, naringenin and internal standard 7-ethoxycoumarin was greater than 70.9%. The method has been applied for the determination of hesperetin and naringenin in urine samples obtained from a male volunteer following a single 300 mg oral dose of each of the corresponding flavanone glycosides hesperidin and naringin. The intra- and inter-day reproducibility through enzyme hydrolysis was less than 3.9% for both total (free + conjugated) hesperetin and naringenin. Stability studies showed urine quality control samples to be stable for both hesperetin and naringenin through three freeze-thaw cycles and at room temperature for 24 h (error < or = 3.6%).

  2. Calcium - urine

    MedlinePlus

    Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...

  3. Evaluation of Equations for Predicting 24-Hour Urinary Sodium Excretion from Casual Urine Samples in Asian Adults.

    PubMed

    Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M

    2016-08-01

    The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.

  4. Urinary casts

    MedlinePlus

    ... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...

  5. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  6. Protoporphyrin IX induced by 5-aminolevulinic acid in bladder cancer cells in voided urine can be extracorporeally quantified using a spectrophotometer.

    PubMed

    Nakai, Yasushi; Anai, Satoshi; Onishi, Sayuri; Masaomi, Kuwada; Tatsumi, Yoshihiro; Miyake, Makito; Chihara, Yoshitomo; Tanaka, Nobumichi; Hirao, Yoshihiko; Fujimoto, Kiyohide

    2015-06-01

    We evaluated the feasibility of photodynamic diagnosis of bladder cancer by spectrophotometric analysis of voided urine samples after extracorporeal treatment with 5-aminolevulinic acid (ALA). Sixty-one patients with bladder cancer, confirmed histologically after the transurethral resection of a bladder tumor, were recruited as the bladder cancer group, and 50 outpatients without history of urothelial carcinoma or cancer-related findings were recruited as the control group. Half of the voided urine sample was incubated with ALA (ALA-treated sample), and the rest was incubated without treatment (ALA-untreated sample). For detecting cellular protoporphyrin IX levels, intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated and ALA-untreated samples at 635 nm was calculated. The differences in the bladder cancer group were significantly greater than those in the control group (p < 0.001). These differences were also significantly greater in patients with high-grade tumors than in those with low-grade tumors (p = 0.004), and also in patients with invasive bladder cancer than in those with noninvasive bladder cancer (p = 0.007). The area under the curve was 0.84. Sensitivity and specificity of the method were 82% and 80%, respectively. We demonstrated that protoporphyrin IX levels in urinary cells treated with ALA could be quantitatively detected by spectrophotometer in patients with bladder cancer. Therefore, this cancer detection system has a potential for clinical use. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Combined Metabolomic Analysis of Plasma and Urine Reveals AHBA, Tryptophan and Serotonin Metabolism as Potential Risk Factors in Gestational Diabetes Mellitus (GDM)

    PubMed Central

    Leitner, Miriam; Fragner, Lena; Danner, Sarah; Holeschofsky, Nastassja; Leitner, Karoline; Tischler, Sonja; Doerfler, Hannes; Bachmann, Gert; Sun, Xiaoliang; Jaeger, Walter; Kautzky-Willer, Alexandra; Weckwerth, Wolfram

    2017-01-01

    Gestational diabetes mellitus during pregnancy has severe implications for the health of the mother and the fetus. Therefore, early prediction and an understanding of the physiology are an important part of prenatal care. Metabolite profiling is a long established method for the analysis and prediction of metabolic diseases. Here, we applied untargeted and targeted metabolomic protocols to analyze plasma and urine samples of pregnant women with and without GDM. Univariate and multivariate statistical analyses of metabolomic profiles revealed markers such as 2-hydroxybutanoic acid (AHBA), 3-hydroxybutanoic acid (BHBA), amino acids valine and alanine, the glucose-alanine-cycle, but also plant-derived compounds like sitosterin as different between control and GDM patients. PLS-DA and VIP analysis revealed tryptophan as a strong variable separating control and GDM. As tryptophan is biotransformed to serotonin we hypothesized whether serotonin metabolism might also be altered in GDM. To test this hypothesis we applied a method for the analysis of serotonin, metabolic intermediates and dopamine in urine by stable isotope dilution direct infusion electrospray ionization mass spectrometry (SID-MS). Indeed, serotonin and related metabolites differ significantly between control and GDM patients confirming the involvement of serotonin metabolism in GDM. Clustered correlation coefficient visualization of metabolite correlation networks revealed the different metabolic signatures between control and GDM patients. Eventually, the combination of selected blood plasma and urine sample metabolites improved the AUC prediction accuracy to 0.99. The detected GDM candidate biomarkers and the related systemic metabolic signatures are discussed in their pathophysiological context. Further studies with larger cohorts are necessary to underpin these observations. PMID:29312952

  8. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    PubMed

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.

  9. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    PubMed Central

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930

  10. Parsley! Mechanism as antiurolithiasis remedy.

    PubMed

    Al-Yousofy, Fayed; Gumaih, Hussein; Ibrahim, Hassan; Alasbahy, Afrah

    2017-01-01

    Parsley is a medicinal plant used widely in urolithiasis. The present study aimed to evaluate the antiurolithiatic effect of parsley and its mechanism. 24 rats divided into four groups: group A (negative control), group B (positive control), group C (cystone ® group) and group D (parsley group). Group B were treated with EG and Ammonium chloride (AC). Group C were treated as B plus cystone ® and group D was treated as B plus parsley. The period of experiment was 15 days. Urine samples were analysis on days 0 and 15 days. Kidneys of rats from all groups were removed, and histopathologically examined. The kidnies of parsley treated group appeared mostly to be calculi-free (less CaOx) even better than the cystone treated group. CaOx crystals was significantly lower both in histological sections and in urine samples in parsley treated group. We further investigated the mechanism of parsley by adding another 6 rats. The latter treated by parsley only after adaptation period. We found significant increase in urine volume and pH in parsley treated rats compared to negative control. We concluded that parsley acts as antiurolithiatic drug through decreasing urinary calcium excretion, increasing urinary pH, dieresis, decreasing urinary protein excretion and its nephroprtective activity. We recommended to use it in pharmaceutical forms as it is safe and effective as antiurolithiasis remedy.

  11. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  12. [Effects of a supplementation on sodium chloride or ammonium chloride on urolithic potential in the rabbit].

    PubMed

    Rückert, Cornelia; Siener, Roswitha; Ganter, Martin; Coenen, Manfred; Vervuert, Ingrid

    2016-08-17

    Reduction of urolithic potential by means of increased water intake and urine dilution through supplementation of sodium chloride (NaCl) or decrease of urine pH by supplementation of ammonium chloride (NH4Cl) in rabbits. Sixteen female, 6-month-old dwarf rabbits received the following three feeding regimens in a random order: complete feed without supplements = control; complete feed + 10 g NaCl/kg feed = NaCl; complete feed + 2.5 g NH4Cl/kg feed = NH4Cl. The diets were fed ad libitum over a period of 27 days without roughage. Water was provided ad libitum by a drinker. A 14-day wash-out-period (hay feeding) was performed between the different diets. Blood, faeces, and urine were collected at the beginning of each feeding period, after 21-day adaptation to the respective diet, and after the 3-day collection period. The following parameters were analysed: water and food intake as well as acid-base balance and mineral content in blood, urine, and faeces. NaCl supplementation numerically increased the daily water intake from 40.5 ± 14.4 ml/kg body weight (BW) (control) up to 49.5 ± 14.3 ml/kg BW and significantly increased the daily urine volume from 16.9 ± 7.8 ml/kg BW (control group) to 21.1 ± 7.4 ml/kg BW. The specific gravity of urine samples from NaCl supplementation decreased from 1.060 ± 0.008 to 1.044 ± 0.008. NH4Cl supplementation did not induce significant changes in urine pH, blood acid-base parameters, or calcium retention. Relative supersaturations (RSS) for calcium oxalate and calcium phosphate showed no significant changes after treatment. RSS for struvite increased from 360 ± 735 (after hay feeding) to 3312 ± 6188 on control feeding, 2910 ± 4913 with NaCl supplementation, and 3022 ± 6635 with NH4Cl supplementation (p < 0.05). NaCl supplementation significantly increased the urine volume and decreased its specific gravity. Therefore, NaCl supplementation might be an additional dietary treatment to increase the elimination of urine crystals in rabbits. NH4Cl supplementation did not induce acidification of the urine.

  13. Determination of a flame retardant hydrolysis product in human urine by SPE and LC-MS. Comparison of molecularly imprinted solid-phase extraction with a mixed-mode anion exchanger.

    PubMed

    Möller, Kristina; Crescenzi, Carlo; Nilsson, Ulrika

    2004-01-01

    Diphenyl phosphate is a hydrolysis product and possible metabolite of the flame retardant and plasticiser additive triphenyl phosphate. A molecularly imprinted polymer solid-phase extraction (MISPE) method for extracting diphenyl phosphate from aqueous solutions has been developed and compared with SPE using a commercially available mixed-mode anion exchanger. The imprinted polymer was prepared using 2-vinylpyridine (2-Vpy) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and a structural analogue of the analyte as the template molecule. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with both aqueous standards and spiked urine samples, by comparing recovery and breakthrough data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from aqueous solutions resulted in more than 80% recovery. Adsorption by the molecularly imprinted polymer (MIP) was non-selective, but selectivity was achieved by selective desorption in the wash steps. Diphenyl phosphate could also be selectively extracted from urine samples, although the urine matrix reduced the capacity of the MISPE cartridges. Recoveries from urine extraction were higher than 70%. It was important to control pH during sample loading. The MISPE method was found to yield a less complex LC-ESI-MS chromatogram of the urine extracts compared with the mixed-mode anion-exchanger method. An LC-ESI-MS method using a Hypercarb LC column with a graphitised carbon stationary phase was also evaluated for organophosphate diesters. LC-ESI-MS using negative-ion detection in selected ion monitoring (SIM) mode was shown to be linear for diphenyl phosphate in the range 0.08-20 ng microL(-1).

  14. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  15. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

    PubMed

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

  16. Collection and storage of urine specimens for measurement of urolithiasis risk factors.

    PubMed

    Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua

    2015-02-01

    To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Effect of a commercial anion dietary supplement on acid-base balance, urine volume, and urinary ion excretion in male goats fed oat or grass hay diets.

    PubMed

    Stratton-Phelps, Meri; House, John K

    2004-10-01

    To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.

  18. Sample preparation and storage can change arsenic speciation in human urine.

    PubMed

    Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C

    1999-11-01

    Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.

  19. The protective arm of the renin-angiotensin system may counteract the intense inflammatory process in fetuses with posterior urethral valves.

    PubMed

    Rocha, Natalia P; Bastos, Fernando M; Vieira, Érica L M; Prestes, Thiago R R; Silveira, Katia D da; Teixeira, Mauro M; Simões E Silva, Ana Cristina

    2018-03-11

    Posterior urethral valve is the most common lower urinary tract obstruction in male children. A high percentage of patients with posterior urethral valve evolve to end-stage renal disease. Previous studies showed that cytokines, chemokines, and components of the renin-angiotensin system contribute to the renal damage in obstructive uropathies. The authors recently found that urine samples from fetuses with posterior urethral valve have increased levels of inflammatory molecules. The aim of this study was to measure renin-angiotensin system molecules and to investigate their correlation with previously detected inflammatory markers in the same urine samples of fetuses with posterior urethral valve. Urine samples from 24 fetuses with posterior urethral valve were collected and compared to those from 22 healthy male newborns at the same gestational age (controls). Renin-angiotensin system components levels were measured by enzyme-linked immunosorbent assay. Fetuses with posterior urethral valve presented increased urinary levels of angiotensin (Ang) I, Ang-(1-7) and angiotensin-converting enzyme 2 in comparison with controls. ACE levels were significantly reduced and Ang II levels were similar in fetuses with posterior urethral valve in comparison with controls. Increased urinary levels of angiotensin-converting enzyme 2 and of Ang-(1-7) in fetuses with posterior urethral valve could represent a regulatory response to the intense inflammatory process triggered by posterior urethral valve. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Urine cell-based DNA methylation classifier for monitoring bladder cancer.

    PubMed

    van der Heijden, Antoine G; Mengual, Lourdes; Ingelmo-Torres, Mercedes; Lozano, Juan J; van Rijt-van de Westerlo, Cindy C M; Baixauli, Montserrat; Geavlete, Bogdan; Moldoveanud, Cristian; Ene, Cosmin; Dinney, Colin P; Czerniak, Bogdan; Schalken, Jack A; Kiemeney, Lambertus A L M; Ribal, Maria J; Witjes, J Alfred; Alcaraz, Antonio

    2018-01-01

    Current standard methods used to detect and monitor bladder cancer (BC) are invasive or have low sensitivity. This study aimed to develop a urine methylation biomarker classifier for BC monitoring and validate this classifier in patients in follow-up for bladder cancer (PFBC). Voided urine samples ( N  = 725) from BC patients, controls, and PFBC were prospectively collected in four centers. Finally, 626 urine samples were available for analysis. DNA was extracted from the urinary cells and bisulfite modificated, and methylation status was analyzed using pyrosequencing. Cytology was available from a subset of patients ( N  = 399). In the discovery phase, seven selected genes from the literature ( CDH13 , CFTR , NID2 , SALL3 , TMEFF2 , TWIST1 , and VIM2 ) were studied in 111 BC and 57 control samples. This training set was used to develop a gene classifier by logistic regression and was validated in 458 PFBC samples (173 with recurrence). A three-gene methylation classifier containing CFTR , SALL3 , and TWIST1 was developed in the training set (AUC 0.874). The classifier achieved an AUC of 0.741 in the validation series. Cytology results were available for 308 samples from the validation set. Cytology achieved AUC 0.696 whereas the classifier in this subset of patients reached an AUC 0.768. Combining the methylation classifier with cytology results achieved an AUC 0.86 in the validation set, with a sensitivity of 96%, a specificity of 40%, and a positive and negative predictive value of 56 and 92%, respectively. The combination of the three-gene methylation classifier and cytology results has high sensitivity and high negative predictive value in a real clinical scenario (PFBC). The proposed classifier is a useful test for predicting BC recurrence and decrease the number of cystoscopies in the follow-up of BC patients. If only patients with a positive combined classifier result would be cystoscopied, 36% of all cystoscopies can be prevented.

  1. Monitoring the endogenous steroid profile disruption in urine and blood upon nandrolone administration: An efficient and innovative strategy to screen for nandrolone abuse in entire male horses.

    PubMed

    Kaabia, Z; Dervilly-Pinel, G; Popot, M A; Bailly-Chouriberry, L; Plou, P; Bonnaire, Y; Le Bizec, B

    2014-04-01

    Nandrolone (17β-hydroxy-4-estren-3-one) is amongst the most misused endogenous steroid hormones in entire male horses. The detection of such a substance is challenging with regard to its endogenous presence. The current international threshold level for nandrolone misuse is based on the urinary concentration ratio of 5α-estrane-3β,17α-diol (EAD) to 5(10)-estrene-3β,17α-diol (EED). This ratio, however, can be influenced by a number of factors due to existing intra- and inter-variability standing, respectively, for the variation occurring in endogenous steroids concentration levels in a single subject and the variation in those same concentration levels observed between different subjects. Targeting an efficient detection of nandrolone misuse in entire male horses, an analytical strategy was set up in order to profile a group of endogenous steroids in nandrolone-treated and non-treated equines. Experiment plasma and urine samples were steadily collected over more than three months from a stallion administered with nandrolone laurate (1 mg/kg). Control plasma and urine samples were collected monthly from seven non-treated stallions over a one-year period. A large panel of steroids of interest (n = 23) were extracted from equine urine and plasma samples using a C18 cartridge. Following a methanolysis step, liquid-liquid and solid-phase extractions purifications were performed before derivatization and analysis on gas chromatography-tandem mass spectrometry (GC-MS/MS) for quantification. Statistical processing of the collected data permitted to establish statistical models capable of discriminating control samples from those collected during the three months following administration. Furthermore, these statistical models succeeded in predicting the compliance status of additional samples collected from racing horses. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Defining the "normal" postejaculate urinalysis.

    PubMed

    Mehta, Akanksha; Jarow, Jonathan P; Maples, Pat; Sigman, Mark

    2012-01-01

    Although sperm have been shown to be present in the postejaculate urinalysis (PEU) of both fertile and infertile men, the number of sperm present in the PEU of the general population has never been well defined. The objective of this study was to describe the semen and PEU findings in both the general and infertile population, in order to develop a better appreciation for "normal." Infertile men (n = 77) and control subjects (n = 71) were prospectively recruited. Exclusion criteria included azoospermia and medications known to affect ejaculation. All men underwent a history, physical examination, semen analysis, and PEU. The urine was split into 2 containers: PEU1, the initial voided urine, and PEU2, the remaining voided urine. Parametric statistical methods were applied for data analysis to compare sperm concentrations in each sample of semen and urine between the 2 groups of men. Controls had higher average semen volume (3.3 ± 1.6 vs 2.0 ± 1.4 mL, P < .001) and sperm concentrations (112 million vs 56.2 million, P = .011), compared with infertile men. The presence of sperm in urine was common in both groups, but more prevalent among infertile men (98.7% vs 88.7%, P = .012), in whom it comprised a greater proportion of the total sperm count (46% vs 24%, P = .022). The majority of sperm present in PEU were seen in PEU1 of both controls (69%) and infertile men (88%). An association was noted between severe oligospermia (<5 million/mL) with low semen volume (<0.5 mL), and significant sperm counts in PEU (<5 million). Although infertile men tend to have a higher proportion of their total sperm in the urine compared with control, there is a large degree of overlap between the 2 populations, making it difficult to identify a specific threshold to define a positive test. Interpretation of a PEU should be directed by whether the number of sperm in the urine could affect subsequent management.

  3. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...

  5. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  6. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    PubMed

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  7. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. [Urinalysis in Italy in 2006].

    PubMed

    Gai, M; Lanfranco, G

    2007-01-01

    Urinalysis and proteinuria testing represent fundamental tests for the clinician, even though they too often lack standardization. Through the Italian Society of Nephrology Mailing List we sent a questionnaire to 282 centers, in order to assess the state of the art in Italy in the year 2006. 82% of the questionnaires were completed (nephrology laboratories: 64%, general laboratories: 36%). The questionnaire dealt with the main steps of preparation, analysis and report of urinalysis, and proteinuria / microalbuminuria measurement. 85% of the centers use first morning urine, and 7% second morning urine; only 57% of the centers supply with written instructions, 189 laboratories (82%) have only one bright field microscope, rate and time of centrifugation are very varied among centers, different units of measurement are used in reports. Few laboratories measure routinely the proteinuria / creatininuria ratio, there is no agreement on the urine sample type for microalbuminuria assay, total urinary proteins are measured through different methods. 92% of the centers is endowed with an internal quality control system, but only 47% participate in an external quality control program. These data confirm the lack of standardization for urine analysis methods and procedures.

  9. Evaluation of chromium, cobalt and manganese in biological samples (scalp hair, blood, and urine) of Pakistani viral hepatitis (A-E) patients and controls.

    PubMed

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Naeemullah; Arain, Sadaf Sadia; Brahman, Kapil Dev; Wadhwa, Sham Kumar

    2013-01-01

    The aim of the present study was to compare the level of chromium (Cr), cobalt (Co), and manganese (Mn) in biological samples (blood, urine, and scalp hair) of patients suffering from different types of viral hepatitis (A, B, C, D, and E; n = 521) of both genders, ages ranging from 31 - 45 years. For comparative study, 255 age-matched control subjects of both genders residing in the same city were selected as referents. The digests of all biological samples were analysed for Cr, Co, and Mn by electrothermal atomic absorption spectrometry (ETAAS). The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and compared with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cr, Co, and Mn were higher in blood and scalp hair samples of hepatitis patients than in age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p <0.001). These results are consistent with literature-reported data, confirming that the overload of these trace elements can directly cause lipid peroxidation and eventually hepatic damage.

  10. Novel micro-extraction by packed sorbent procedure for the liquid chromatographic analysis of antiepileptic drugs in human plasma and urine.

    PubMed

    Rani, Susheela; Malik, Ashok K; Singh, Baldev

    2012-02-01

    A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    PubMed

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  12. Is a pre-analytical process for urinalysis required?

    PubMed

    Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole

    2017-10-01

    For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.

  13. Urine metabolomics in neonates with late-onset sepsis in a case-control study

    NASA Astrophysics Data System (ADS)

    Sarafidis, Kosmas; Chatziioannou, Anastasia Chrysovalantou; Thomaidou, Agathi; Gika, Helen; Mikros, Emmanouel; Benaki, Dimitra; Diamanti, Elisavet; Agakidis, Charalampos; Raikos, Nikolaos; Drossou, Vasiliki; Theodoridis, Georgios

    2017-04-01

    Although late-onset sepsis (LOS) is a major cause of neonatal morbidity and mortality, biomarkers evaluated in LOS lack high diagnostic accuracy. In this prospective, case-control, pilot study, we aimed to determine the metabolic profile of neonates with LOS. Urine samples were collected at the day of initial LOS evaluation, the 3rd and 10th day, thereafter, from 16 septic neonates (9 confirmed and 7 possible LOS cases) and 16 non-septic ones (controls) at respective time points. Urine metabolic profiles were assessed using non-targeted nuclear magnetic resonance spectroscopy and targeted liquid chromatography-tandem mass spectrometry analysis. Multivariate statistical models with data from either analytical approach showed clear separation between the metabolic profiles of septic neonates (both possible and confirmed) and the controls. Metabolic changes appeared to be related to disease progression. Overall, neonates with confirmed or possible LOS exhibited comparable metabolic profiles indicating similar metabolic alternations upon the onset of clinical manifestations. This methodology therefore enabled the discrimination of neonates with LOS from non-septic individuals, providing potential for further research toward the discovery of LOS-related biomarkers.

  14. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  15. Comparison of urine and bladder or urethral mucosal biopsy culture obtained by transurethral cystoscopy in dogs with chronic lower urinary tract disease: 41 cases (2002 to 2011).

    PubMed

    Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R

    2014-07-01

    To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.

  16. Quantification of six herbicide metabolites in human urine.

    PubMed

    Norrgran, Jessica; Bravo, Roberto; Bishop, Amanda M; Restrepo, Paula; Whitehead, Ralph D; Needham, Larry L; Barr, Dana B

    2006-01-18

    We developed a sensitive, selective and precise method for measuring herbicide metabolites in human urine. Our method uses automated liquid delivery of internal standards and acetate buffer and a mixed polarity polymeric phase solid phase extraction of a 2 mL urine sample. The concentrated eluate is analyzed using high-performance liquid chromatography-tandem mass spectrometry. Isotope dilution calibration is used for quantification of all analytes. The limits of detection of our method range from 0.036 to 0.075 ng/mL. The within- and between-day variation in pooled quality control samples range from 2.5 to 9.0% and from 3.2 to 16%, respectively, for all analytes at concentrations ranging from 0.6 to 12 ng/mL. Precision was similar with samples fortified with 0.1 and 0.25 ng/mL that were analyzed in each run. We validated our selective method against a less selective method used previously in our laboratory by analyzing human specimens using both methods. The methods produced results that were in agreement, with no significant bias observed.

  17. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    PubMed

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  18. Detection of human papillomavirus DNA in urine. A review of the literature.

    PubMed

    Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P

    2012-05-01

    The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.

  19. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...

  1. Effects of exercise on the urinary proteome.

    PubMed

    Kohler, Maxie; Schänzer, Wilhelm; Thevis, Mario

    2015-01-01

    Exercise-induced proteinuria has been observed and studied for more than a century. It was found that different sport disciplines alter the urinary proteome in different ways. Moderate-intensity exercise results in increased glomerular filtration, meaning that medium-sized proteins are excreted in higher amounts, while high-intensity exercise of short duration also increases the excretion of low molecular weight proteins as a result of tubular dysfunction. Exhaustive exercise may lead to the excretion of hemoglobin or myoglobin, which changes the urinary proteome considerably. Studies comparing protein maps of different sport types compared to a control group showed that quality and quantity of urinary proteins are interindividually different. In addition, urine samples collected before and after exercise exhibit substantially different protein patterns even from the same person. Therefore, further studies investigating the urinary proteome are desirable. As the variation of protein content and composition in urine are generally much higher than in other matrices, respective studies need to be well controlled and homogenous groups of volunteers should be chosen. In addition to the sport-related physiological and biochemical interest, exercise-induced protein changes also need to be considered for biomarker measurements from urine samples for kidney or other diseases.

  2. An untargeted approach for the analysis of the urine peptidome of women with preeclampsia.

    PubMed

    Kononikhin, A S; Starodubtseva, N L; Bugrova, A E; Shirokova, V A; Chagovets, V V; Indeykina, M I; Popov, I A; Kostyukevich, Y I; Vavina, O V; Muminova, K T; Khodzhaeva, Z S; Kan, N E; Frankevich, V E; Nikolaev, E N; Sukhikh, G T

    2016-10-21

    Preeclampsia (PE) is a pregnancy complication characterized by high blood pressure and proteinuria. The disorder usually occurs after the 20th week of pregnancy and gets worse over time. PE increases the risk of poor outcomes for both the mother and the baby. In the study we applied LC-MS/MS method for the analysis of the urine peptidome of women with PE. Samples were prepared using size-exclusion chromatography method which gives more than twice peptides identities if compared with solid phase extraction. Thirty urine samples from women with mild and severe preeclampsia and the control group were analyzed. In total 1786 peptides were identified using complementary search engines (Mascot, MaxQuant and PEAKS). A high level of agreement in peptide identification was observed with previously published data. Label-free data comparison resulted in 35 peptides which reliably distinguished a particular PE group (severe or mild) from controls. Our results revealed unique identifications (correlate to alpha-1-antitrypsin, collagen alpha-1(I) chain, collagen alpha-1 (III) chain, and uromodulin, for instance) that can potentially serve as early indicators of PE. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Urinary metabolomic study of non-small cell lung carcinoma based on ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    PubMed

    Wu, Qian; Wang, Yan; Gu, Xue; Zhou, Junyi; Zhang, Huiping; Lv, Wang; Chen, Zhe; Yan, Chao

    2014-07-01

    Metabolic profiles from human urine reveal the significant difference of carnitine and acylcarnitines levels between non-small cell lung carcinoma patients and healthy controls. Urine samples from cancer patients and healthy individuals were assayed in this metabolomic study using ultra high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry. The data were normalized by the sum of all intensities and creatinine calibration, respectively, before orthogonal partial least squares discriminant analysis. Twenty differential metabolites were identified based on standard compounds or tandem mass spectrometry fragments. Among them, some medium-/long-chain acylcarnitines, for example, cis-3,4-methylene heptanoylcarnitine, were found to be downregulated while carnitine was upregulated in urine samples from the cancer group compared to the control group. Receiver operating characteristic analysis of the two groups showed that the area under curve for the combination of carnitine and 11 selected acylcarnitines was 0.958. This study suggests that the developed carnitine and acylcarnitines profiling method has the potential to be used for screening non-small cell lung carcinoma. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  5. Biomonitoring of N-ethyl-2-pyrrolidone in automobile varnishers.

    PubMed

    Koslitz, Stephan; Meier, Swetlana; Schindler, Birgit Karin; Weiss, Tobias; Koch, Holger Martin; Brüning, Thomas; Käfferlein, Heiko Udo

    2014-12-01

    N-alkyl-2-pyrrolidones are important organic solvents for varnishes in industry. This study investigates exposure to N-ethyl-2-pyrrolidone (NEP) in varnishing of hard plastic components in an automobile plant. Two specific biomarkers of exposure, 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), were analyzed in urine samples of 14 workers. For this purpose, pre-shift, post-shift and next day pre-shift urine samples were collected midweek. Twelve workers performed regular work tasks (loading, wiping and packing), whereas two workers performed special work tasks including cleaning the sprayer system with organic solvents containing N-alkyl-2-pyrrolidones. Spot urine samples of nine non-exposed persons of the same plant served as controls. Median post-shift urinary levels of workers with regular work tasks (5-HNEP: 0.15 mg/L; 2-HESI: 0.19 mg/L) were ∼5-fold higher compared to the controls (0.03 mg/L each). Continuously increasing metabolite levels, from pre-shift via post-shift to pre-shift samples of the following day, were observed in particular for the two workers with the special working tasks. Maximum levels were 31.01 mg/L (5-HNEP) and 8.45 mg/L (2-HESI). No clear trend was evident for workers with regular working tasks. In summary, we were able to show that workers can be exposed to NEP during varnishing tasks in the automobile industry. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

    PubMed

    Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A

    2003-01-15

    To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

  7. Mutagenic activity of overnight urine from healthy non-smoking subjects.

    PubMed

    Pavanello, Sofia; Lupi, Silvia; Pulliero, Alessandra; Gregorio, Pasquale; Saia, Bruno Onofrio; Clonfero, Erminio

    2007-03-01

    Urinary mutagenicity was evaluated in relation to environmental mutagen exposure (i.e., diet, indoor/outdoor activities, residential area etc.) on the day prior to sample collection, and also considering factors that contribute to the variability of Salmonella mutagenicity assay results. Overnight urine samples from 283 healthy non-smoking residents of northeast Italy (46% males, 20-62 years) were analyzed for mutagenicity on sensitive Salmonella typhimurium strain YG1024 with S9 mix employing the preincubation version of the plate incorporation assay (i.e., the Salmonella reverse mutation test). Urinary mutagenicity varied between 0.02 and 9.84 rev/ equiv. ml, and 7% of samples were positive (i.e., sample elicited a two-fold increase in revertants). There was an evident increase in mutagenicity in subjects with increased intake of mutagen-rich meals (n = 80) (P < 0.01 and positive urine 13% vs. 5%, P = 0.025). Indoor-exposed subjects (n = 65) also showed a higher percentage of positive urine (14% vs. 5%, P = 0.015). In particular, those subjects exposed to cooking fumes the previous evening (n = 28) revealed higher urinary mutagenicity (P = 0.035, positive urine 25% vs. 5%, P < 0.001) than non-indoor exposed. The sources of variability of the mutagenicity assay, mainly the histidine content of the urine concentrate (z = 4.06, P < 0.0001), and to a lesser extent bacterial inoculum size (z = 2.33, P = 0.019), also significantly influenced urinary mutagenicity values. In a linear multiple regression analysis, their effects were still significant (i.e., histidine content P = 0.026 and inoculum size P = 0.021), but the effects of diet, indoor exposure, and other environmental exposures (i.e., traffic and heating system exhausts, residential area) were not. It is concluded that the previous day's exposure to mutagen-rich meals and cooking fumes may influence the presence of mutagenic activity in the overnight urine of non-smoking subjects. This mutagenic activity, which remains in contact with bladder mucosa for several hours, could be considered risk factors for colorectal adenoma and possibly other cancers (i.e., bladder) in non-smokers. Accurate control of histidine content and bacterial inoculum size is strongly recommended when investigating the mutagenic activity of urine from non-smokers. (c) 2007 Wiley-Liss, Inc.

  8. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  9. Albumin adsorption onto surfaces of urine collection and analysis containers.

    PubMed

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Manganese in exhaled breath condensate: a new marker of exposure to welding fumes.

    PubMed

    Hulo, Sébastien; Chérot-Kornobis, Nathalie; Howsam, Mike; Crucq, Sébastien; de Broucker, Virginie; Sobaszek, Annie; Edme, Jean-Louis

    2014-04-07

    To evaluate manganese in exhaled breath condensate (Mn-EBC) as an indicator of exposure to fumes from metal inert gas welding process. We collected EBC and urine from 17 welders and 16 unexposed control subjects after 5 days exposure. Concentrations of manganese (Mn), nickel (Ni), iron (Fe) and chromium (Cr) were measured in EBC and urine samples and correlated with cumulative exposure indices for the working week (CIW) and for the total welding years (WY), based on duration of welding activity and atmospheric metal measurements. Concentrations of Mn and Ni in EBC were significantly higher among welders than controls whereas this difference was not significant for Mn in urine. Levels of Mn and Ni in EBC were not correlated with their respective levels in urine. The linear regressions found significant positive coefficients between Mn-EBC, Ni-EBC, Ni-U and Cr-U concentrations and the cumulative exposure indices. Taking into account tobacco use, statistical analysis showed the same trends except for the relationship between Mn-U and CIW. This pilot study showed that Mn-EBC, as well as Ni-EBC, can serve as reliable indices of occupational exposure to welding fumes and provide complimentary toxicokinetic information to that provided by urine analyses. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Solid phase extraction of 2,4-D from human urine.

    PubMed

    Thompson, T S; Treble, R G

    1996-10-01

    A method for determining urinary concentrations of 2,4-D in samples collected from non-occupationally, environmentally exposed individuals was developed. The 2,4-D was extracted from fortified human urine samples using octadecylsilane solid phase extraction cartridges. The average percent recovery for urine samples spiked at 2 and 20 ng/mL was 100% and 93%, respectively. The method detection limit was estimated to be 0.75 ng of 2,4-D per mL of urine based on a 10 mL sample size. The potential use of 2,4-dichlorophenylacetic acid as a surrogate standard was also investigated.

  12. Direct trace-elemental analysis of urine samples by laser ablation-inductively coupled plasma mass spectrometry after sample deposition on clinical filter papers.

    PubMed

    Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín

    2012-10-16

    Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.

  13. Possible application of urinary analysis to estimate dissolution of some man-made vitreous fibers.

    PubMed Central

    Wastiaux, A; Blanchard, O; Honnons, S

    1994-01-01

    A preliminary study at the institut National de l'Environnement Industriel et des Risques (INERIS) examined the dissolution of three man-made vitreous fiber samples (glasswool, rockwool, glass microfibers: JM 100) after intraperitoneal injections in male Wistar rats. The chemical composition of the original fibers was determined by inductively coupled plasma spectrometry (ICP). The urine of the rats was collected at fixed times between day 1 and day 204, and the ICP was used to look for elements known to be present in the original fibers. At day 204, a piece of omentum was removed at autopsy, ashed and analyzed by energy dispersive X-ray analysis (EDXA) to identify the elements remaining in the fibers. Silicon and aluminium were retained in the fibers from all samples at day 204. Losses in calcium, sodium, magnesium, and sulfur were observed, but these elements were not studied in the urine samples because they are naturally present in relatively high concentrations in rat cells and biological fluids. Although there was a loss of zinc from the glass microfibers, no corresponding difference was observed between the zinc levels excreted by the treated animals and by the controls. Similarly, despite the loss of manganese from the rockwool fibers at day 204, none was detectable in the urine samples. Titanium, present at the 0.3% level in rockwool, was not detectable by EDXA at day 204, but small quantities were detected in the first 2 weeks in the urine samples of rats treated with rockwool.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7882936

  14. A randomised trial to investigate the effects of acute consumption of a blackcurrant juice drink on markers of vascular reactivity and bioavailability of anthocyanins in human subjects.

    PubMed

    Jin, Y; Alimbetov, D; George, T; Gordon, M H; Lovegrove, J A

    2011-07-01

    To study the bioavailability of anthocyanins and the effects of a 20% blackcurrant juice drink on vascular reactivity, plasma antioxidant status and other cardiovascular disease risk markers. The study was a randomised, cross-over, double-blind, placebo-controlled acute meal study. Twenty healthy volunteers (11 females and 9 males) were recruited, and all subjects completed the study. Fasted volunteers consumed a 20% blackcurrant juice drink (250 ml) or a control drink following a low-flavonoid diet for the previous 72 h. Vascular reactivity was assessed at baseline and 120 min after juice consumption by laser Doppler imaging (LDI). Plasma and urine samples were collected periodically over an 8-h period for analysis, with a final urine sample collected at 24 h. The cross-over was performed after a 4-week washout. There were no significant effects of the 20% blackcurrant juice drink on acute measures of vascular reactivity, biomarkers of endothelial function or lipid risk factors. Consumption of the test juice caused increases in plasma vitamin C (P=0.006), and urinary anthocyanins (P<0.001). Delphinidin-3-rutinoside and cyanidin-3-rutinoside were the main anthocyanins excreted in urine with delphinidin-3-glucoside also detected. The yield of anthocyanins in urine was 0.021±0.003% of the dietary intake of delphinidin glycosides and 0.009±0.002% of the dietary intake of cyanidin glycosides. The juice consumption did not have a significant effect on vascular reactivity. Anthocyanins were present at low concentrations in the urine, and microbial metabolites of flavonoids were detected in plasma after juice consumption.

  15. Agreement between twenty-four hour salt ingestion and sodium excretion in a controlled environment

    PubMed Central

    Lerchl, Kathrin; Rakova, Natalia; Dahlmann, Anke; Rauh, Manfred; Goller, Ulrike; Basner, Mathias; Dinges, David F.; Beck, Luis; Agureev, Alexander; Larina, Irina; Baranov, Victor; Morukov, Boris; Eckardt, Kai-Uwe; Vassilieva, Galina; Wabel, Peter; Vienken, Jörg; Kirsch, Karl; Johannes, Bernd; Krannich, Alexander; Luft, Friedrich C.; Titze, Jens

    2015-01-01

    Accurately collected 24-hour urine collections are presumed to be valid for estimating salt intake in individuals. We performed two independent ultra-long-term salt balance studies lasting 105 (4 men) and 205 (6 men) days in 10 men simulating a flight to Mars. We controlled dietary intake of all constituents for months at salt intakes of 12, 9, and 6 grams per day and collected all urine. The subjects’ daily menus consisted of 27,279 individual servings, out of which 83.0% were completely consumed, 16.5% completely rejected, and 0.5% incompletely consumed. Urinary recovery of dietary salt was 92% of recorded intake, indicating long-term steady state sodium balance in both studies. Even at fixed salt intake, 24-hour sodium excretion (UNaV) showed infradian rhythmicity. We defined a ±25 mmol deviation from the average difference between recorded sodium intake and UNaV as the prediction interval to accurately classify a 3-gram difference in salt intake. Due to the biological variability in UNaV, only every-other daily urine sample correctly classified a 3-gram difference in salt intake (49%). By increasing the observations to three consecutive 24-hour collections and sodium intakes, classification accuracy improved to 75%. Collecting seven 24-hour urines and sodium intake samples improved classification accuracy to 92%. We conclude that single 24-hour urine collections at intakes ranging from 6–12 grams salt per day were not suitable to detect a 3-gram difference in individual salt intake. Repeated measurements of 24-hour UNaV improve precision. This knowledge could be relevant to patient care and the conduct of intervention trials. PMID:26259596

  16. Biomonitoring of boron: Development and characterization of a simple, reliable and quality controlled biomonitoring method.

    PubMed

    Michalke, Bernhard

    2017-03-01

    Boron exposure is of interest and concern from an occupational point of view. Usual daily boron intake is related to boron blood plasma concentration <1mg/L and to <3mg/L in urine, but after exposure urine concentrations are quickly elevated. Reliable boron biomonitoring, typically in urine, thus is mandatory for occupational health control institutions. This paper reports on the development of a simple, fast and reliable boron determination procedure based on inductively coupled plasma - optical emission spectrometry (ICP-OES). Major aims for this method were simplicity in sample preparation, low risk for artifacts and interferences, high precision and accuracy, possibly low costs, including lower costs for element selective detection, short total analysis time and suitability for occupational health laboratories. Precision data (serial or day-to-day) from urine and doped urine were very good: <1.5 or <2%. Accuracy was calculated from analysis of a certified reference material (ERM-CD 281), as 99% or according to recoveries of doped concentrations ranging from 102 to 109% recovery. For cross-checking ICP-OES determinations, samples were analyzed also by quadrupole ICP-qMS and by sectorfield ICP-sf-MS at low and medium resolution. Both systems confirmed ICP-OES measurements when using 11 B for quantification. Determinations based on 10 B however showed some bias, except with ICP-sf-MS at medium resolution. The observed elevated signals are discussed with respect to the known Ne ++ interference (as an impurity in Ar), which is not separated in low resolving quadrupole ICP-MS systems or ICP-sf-MS at low resolution. Copyright © 2016 Elsevier GmbH. All rights reserved.

  17. Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption.

    PubMed

    Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S

    2010-02-15

    Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.

  18. BKV infection and hemorrhagic cystitis after allogeneic bone marrow transplant.

    PubMed

    Fioriti, D; Degener, A M; Mischitelli, M; Videtta, M; Arancio, A; Sica, S; Sora, F; Pietropaolo, V

    2005-01-01

    Hemorrhagic cystitis (HC) is a well-known complication after allogeneic bone marrow transplant (BMT) and can be related to adenovirus or human polyomavirus BK (BKV) infections. In this study a group of 20 patients after allogeneic BMT has been examined. BMT urine samples were analysed for the presence of Adenovirus and BKV DNAby means of polymerase chain reaction (PCR). 5/20 BMT patients developed HC after BMT. The presence of BKV DNA in urine samples was evident in 3/15 patients without HC and in 5/5 patients with HC. In 2/5 HC-patients the BKV DNA was not found after therapy with Cidofovir and Ribavirin. The search for adenovirus DNA in all samples was negative. The analysis of BKV non-coding control region (NCCR) isolated from urine samples revealed a structure very similar to the archetype in all samples. The RFLP (Restriction Fragment Length Polymorphism assay) showed the presence of BKV subtypes I and IV, with the prevalence of subtype I (4/5). This study supports the hypothesis that HC is mainly related to BKV rather than to adenovirus infection in BMT patients. Moreover, since BKV subtype I was predominant, it is reasonable to hypothesize that a specific BKV subtype could be associated with the development of HC.

  19. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    PubMed

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Testing for nandrolone metabolites in urine samples of professional athletes and sedentary subjects by GC/MS/MS analysis.

    PubMed

    Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero

    2002-12-01

    The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.

  1. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  3. Direct and rapid mass spectral fingerprinting of maternal urine for the detection of Down syndrome pregnancy.

    PubMed

    Iles, Ray K; Shahpari, Maryam E; Cuckle, Howard; Butler, Stephen A

    2015-01-01

    The established methods of antenatal screening for Down syndrome are based on immunoassay for a panel of maternal serum biomarkers together with ultrasound measures. Recently, genetic analysis of maternal plasma cell free (cf) DNA has begun to be used but has a number of limitations including excessive turn-around time and cost. We aimed to develop an alternative method based on urinalysis that is simple, affordable and accurate. 101 maternal urine samples sampled at 12-17 weeks gestation were taken from an archival collection of 2567 spot urines collected from women attending a prenatal screening clinic. 18 pregnancies in this set subsequently proved to be Down pregnancies. Samples were either neat urine or diluted between 10 to 1000 fold in dH2O and subjected to matrix assisted laser desorption ionization (MALDI), time of flight (ToF) mass spectrometry (MS). Data profiles were examined in the region 6,000 to 14,000 m/z. Spectral data was normalised and quantitative characteristics of the profile were compared between Down and controls. In Down cases there were additional spectral profile peaks at 11,000-12,000 m/z and a corresponding reduction in intensity at 6,000-8,000 m/z. The ratio of the normalised values at these two ranges completely separated the 8 Down syndrome from the 39 controls at 12-14 weeks. Discrimination was poorer at 15-17 weeks where 3 of the 10 Down syndrome cases had values within the normal range. Direct MALDI ToF mass spectral profiling of maternal urinary has the potential for an affordable, simple, accurate and rapid alternative to current Down syndrome screening protocols.

  4. Methodology for a vaginal and urinary microbiome study in women with mixed urinary incontinence.

    PubMed

    Komesu, Yuko M; Richter, Holly E; Dinwiddie, Darrell L; Siddiqui, Nazema Y; Sung, Vivian W; Lukacz, Emily S; Ridgeway, Beri; Arya, Lily A; Zyczynski, Halina M; Rogers, Rebecca G; Gantz, Marie

    2017-05-01

    We describe the rationale and methods of a study designed to compare vaginal and urinary microbiomes in women with mixed urinary incontinence (MUI) and similarly aged, asymptomatic controls. This paper delineates the methodology of a supplementary microbiome study nested in an ongoing randomized controlled trial comparing a standardized perioperative behavioral/pelvic floor exercise intervention plus midurethral sling versus midurethral sling alone for MUI. Women in the parent study had at least "moderate bother" from urgency and stress urinary incontinence symptoms (SUI) on validated questionnaire and confirmed MUI on bladder diary. Controls had no incontinence symptoms. All participants underwent vaginal and urine collection for DNA analysis and conventional urine culture. Standardized protocols were designed, and a central lab received samples for subsequent polymerase chain reaction (PCR) amplification and sequencing of the bacterial16S ribosomal RNA (rRNA) gene. The composition of bacterial communities will be determined by dual amplicon sequencing of variable regions 1-3 and 4-6 from vaginal and urine specimens to compare the microbiome of patients with controls. Sample-size estimates determined that 126 MUI and 84 control participants were sufficient to detect a 20 % difference in predominant urinary genera, with 80 % power and 0.05 significance level. Specimen collection commenced January 2015 and finished April 2016. DNA was extracted and stored for subsequent evaluation. Methods papers sharing information regarding development of genitourinary microbiome studies, particularly with control populations, are few. We describe the rigorous methodology developed for a novel urogenital microbiome study in women with MUI.

  5. A Therapeutic Workplace for the Long-Term Treatment of Drug Addiction and Unemployment: Eight-Year Outcomes of a Social Business Intervention

    PubMed Central

    Aklin, Will M.; Wong, Conrad J.; Hampton, Jacqueline; Svikis, Dace S.; Stitzer, Maxine L.; Bigelow, George E.; Silverman, Kenneth

    2014-01-01

    This study evaluated the long-term effects of a Therapeutic Workplace social business on drug abstinence and employment. Pregnant and postpartum women (N=40) enrolled in methadone treatment were randomly assigned to a Therapeutic Workplace or Usual Care Control group. Therapeutic Workplace participants could work weekdays in training and then as employees of a social business, but were required to provide drug-free urine samples to work and maintain maximum pay. Three-year outcomes were reported previously. This paper reports 4- to 8- year outcomes. During year 4 when the business was open, Therapeutic Workplace participants provided significantly more cocaine- and opiate-negative urine samples than controls; reported more days employed, higher employment income, and less money spent on drugs. During the 3 years after the business closed, Therapeutic Workplace participants only reported higher income than controls. A Therapeutic Workplace social business can maintain long-term abstinence and employment, but additional intervention may be required to sustain effects. PMID:25124257

  6. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

    PubMed

    Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A

    2011-03-01

    The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.

  7. Variability of Organophosphorous Pesticide Metabolite Levels in Spot and 24-hr Urine Samples Collected from Young Children during 1 Week

    PubMed Central

    Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda

    2012-01-01

    Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012

  8. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  9. Untargeted metabolomic on urine samples after α-lipoic acid and/or eicosapentaenoic acid supplementation in healthy overweight/obese women.

    PubMed

    Romo-Hualde, Ana; Huerta, Ana E; González-Navarro, Carlos J; Ramos-López, Omar; Moreno-Aliaga, María J; Martínez, J Alfredo

    2018-05-09

    Eicosapentaenoic acid (EPA) and α-lipoic acid (α-LA) have been investigated for their beneficial effects on obesity and cardiovascular risk factors. In the current research, the goal was to evaluate metabolomic changes following the dietary supplementation of these two lipids, alone or combined in healthy overweight/obese sedentary women following an energy-restricted diet. For this purpose, an untargeted metabolomics approach was conducted on urine samples using liquid chromatography coupled with time of flight mass spectrometry (HPLC-TOF-MS). This is a short-term double blind placebo-controlled study with a parallel nutritional design that lasted 10 weeks. Participants were assigned to one of the 4 experimental groups [Control, EPA (1.3 g/d), α-LA (0.3 g/d) and EPA+α-LA (1.3 g/d + 0.3 g/d)]. All intervention groups followed an energy-restricted diet of 30% less than total energy expenditure. Clinically relevant biochemical measurements were analyzed. Urine samples (24 h) were collected at baseline and after 10 weeks. Untargeted metabolomic analysis on urine samples was carried out, and principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) were performed for the pattern recognition and characteristic metabolites identification. Urine samples were scattered in the PCA scores plots in response to the supplementation with α-LA. Totally, 28 putative discriminant metabolites in positive ionization, and 6 in negative ionization were identified among groups clearly differentiated according to the α-LA administration. Remarkably is the presence of an ascorbate intermediate metabolite (one of the isomers of trihydroxy-dioxohexanoate, or dihydroxy-oxohexanedionate) in the groups supplemented with α-LA. This fact might be associated with antioxidant properties of both α-LA and ascorbic acid. Correlations between phenotypical parameters and putative metabolites of provided additional information on whether there is a direct or inverse relationship between them. Especially interesting are the negative correlation between ascorbate intermediate metabolite and asymmetric dimethylarginine (ADMA) and the positive one between superoxide dismutase (SOD) and α-LA supplementation. This metabolomic approach supports that the beneficial effects of α-LA administration on body weight reduction may be partly explained by the antioxidant properties of this organosulfur carboxylic acid mediated by isomers of trihydroxy-dioxohexanoate, or dihydroxy-oxohexanedionate. Clinicaltrials.gov NCT01138774 .

  10. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  11. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  13. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were < 6% and < 13%, respectively. This procedure has been applied to quality-control specimens and LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  14. A reinforcement-based therapeutic workplace for the treatment of drug abuse: six-month abstinence outcomes.

    PubMed

    Silverman, K; Svikis, D; Robles, E; Stitzer, M L; Bigelow, G E

    2001-02-01

    This study evaluated a novel drug abuse treatment, the Therapeutic Workplace. In this treatment, patients are paid to perform jobs or to participate in job training. Salary is linked to abstinence by requiring patients to provide drug-free urine samples to gain access to the workplace. Pregnant and postpartum drug abuse patients (N = 40) were randomly assigned to a Therapeutic Workplace or usual care control group. Therapeutic Workplace participants were invited to work 3 hr every weekday for 6 months and could earn up to $4,030 in vouchers for abstinence, workplace attendance, and performance. On average, 45% of participants attended the workplace per day. Relative to controls, the Therapeutic Workplace nearly doubled patients' abstinence from opiates and cocaine (33% vs. 59% of thrice-weekly urine samples drug negative, respectively, p < .05). The Therapeutic Workplace can effectively treat heroin and cocaine abuse in pregnant and postpartum women.

  15. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  16. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  17. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  18. Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.

    PubMed

    Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai

    2015-01-01

    The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.

  19. Assessment of 1H NMR-based metabolomics analysis for normalization of urinary metals against creatinine.

    PubMed

    Cassiède, Marc; Nair, Sindhu; Dueck, Meghan; Mino, James; McKay, Ryan; Mercier, Pascal; Quémerais, Bernadette; Lacy, Paige

    2017-01-01

    Proton nuclear magnetic resonance ( 1 H NMR, or NMR) spectroscopy and inductively coupled plasma-mass spectrometry (ICP-MS) are commonly used for metabolomics and metal analysis in urine samples. However, creatinine quantification by NMR for the purpose of normalization of urinary metals has not been validated. We assessed the validity of using NMR analysis for creatinine quantification in human urine samples in order to allow normalization of urinary metal concentrations. NMR and ICP-MS techniques were used to measure metabolite and metal concentrations in urine samples from 10 healthy subjects. For metabolite analysis, two magnetic field strengths (600 and 700MHz) were utilized. In addition, creatinine concentrations were determined by using the Jaffe method. Creatinine levels were strongly correlated (R 2 =0.99) between NMR and Jaffe methods. The NMR spectra were deconvoluted with a target database containing 151 metabolites that are present in urine. A total of 50 metabolites showed good correlation (R 2 =0.7-1.0) at 600 and 700MHz. Metal concentrations determined after NMR-measured creatinine normalization were comparable to previous reports. NMR analysis provided robust urinary creatinine quantification, and was sufficient for normalization of urinary metal concentrations. We found that NMR-measured creatinine-normalized urinary metal concentrations in our control subjects were similar to general population levels in Canada and the United Kingdom. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Estimating population salt intake in India using spot urine samples.

    PubMed

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  1. Urine metabonomic profiling of a female adolescent with PIT-1 mutation before and during growth hormone therapy: insights into the metabolic effects of growth hormone.

    PubMed

    Abd Rahman, Shaffinaz; Schirra, Horst Joachim; Lichanska, Agnieszka M; Huynh, Tony; Leong, Gary M

    2013-01-01

    Growth hormone (GH) is a protein hormone with important roles in growth and metabolism. The objective of this study was to investigate the metabolism of a human subject with severe GH deficiency (GHD) due to a PIT-1 gene mutation and the metabolic effects of GH therapy using Nuclear Magnetic Resonance (NMR)-based metabonomics. NMR-based metabonomics is a platform that allows the metabolic profile of biological fluids such as urine to be recorded, and any alterations in the profile modulated by GH can potentially be detected. Urine samples were collected from a female subject with severe GHD before, during and after GH therapy, and from healthy age- and sex-matched controls and analysed with NMR-based metabonomics. The samples were collected at a hospital and the study was performed at a research facility. We studied a 17 year old female adolescent with severe GHD secondary to PIT-1 gene mutation who had reached final adult height and who had ceased GH therapy for over 3 years. The subject was subsequently followed for 5 years with and without GH therapy. Twelve healthy age-matched female subjects acted as control subjects. The GH-deficient subject re-commenced GH therapy at a dose of 1 mg/day to normalise serum IGF-1 levels. Urine metabolic profiles were recorded using NMR spectroscopy and analysed with multivariate statistics to distinguish the profiles at different time points and identify significant metabolites affected by GH therapy. NMR-based metabonomics revealed that the metabolic profile of the GH-deficient subject altered with GH therapy and that her profile was different from healthy controls before, and during withdrawal of GH therapy. This study illustrates the potential use of NMR-based metabonomics for monitoring the effects of GH therapy on metabolism by profiling the urine of GH-deficient subjects. Further controlled studies in larger numbers of GH-deficient subjects are required to determine the clinical benefits of NMR-based metabonomics in subjects receiving GH therapy. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Correlating the amount of urea, creatinine, and glucose in urine from patients with diabetes mellitus and hypertension with the risk of developing renal lesions by means of Raman spectroscopy and principal component analysis

    NASA Astrophysics Data System (ADS)

    Bispo, Jeyse Aliana Martins; de Sousa Vieira, Elzo Everton; Silveira, Landulfo; Fernandes, Adriana Barrinha

    2013-08-01

    Patients with diabetes mellitus and hypertension (HT) diseases are predisposed to kidney diseases. The objective of this study was to identify potential biomarkers in the urine of diabetic and hypertensive patients through Raman spectroscopy in order to predict the evolution to complications and kidney failure. Urine samples were collected from control subjects (CTR) and patients with diabetes and HT with no complications (lower risk, LR), high degree of complications (higher risk, HR), and doing blood dialysis (DI). Urine samples were stored frozen (-20°C) before spectral analysis. Raman spectra were obtained using a dispersive spectrometer (830-nm, 300-mW power, and 20-s accumulation). Spectra were then submitted to principal component analysis (PCA) followed by discriminant analysis. The first PCA loading vectors revealed spectral features of urea, creatinine, and glucose. It has been found that the amounts of urea and creatinine decreased as disease evoluted from CTR to LR/HR and DI (PC1, p<0.05), and the amount of glucose increased in the urine of LR/HR compared to CTR (PC3, p<0.05). The discriminating model showed better overall classification rate of 70%. These results could lead to diagnostic information of possible complications and a better disease prognosis.

  3. Correlating the amount of urea, creatinine, and glucose in urine from patients with diabetes mellitus and hypertension with the risk of developing renal lesions by means of Raman spectroscopy and principal component analysis.

    PubMed

    Bispo, Jeyse Aliana Martins; de Sousa Vieira, Elzo Everton; Silveira, Landulfo; Fernandes, Adriana Barrinha

    2013-08-01

    Patients with diabetes mellitus and hypertension (HT) diseases are predisposed to kidney diseases. The objective of this study was to identify potential biomarkers in the urine of diabetic and hypertensive patients through Raman spectroscopy in order to predict the evolution to complications and kidney failure. Urine samples were collected from control subjects (CTR) and patients with diabetes and HT with no complications (lower risk, LR), high degree of complications (higher risk, HR), and doing blood dialysis (DI). Urine samples were stored frozen (-20°C) before spectral analysis. Raman spectra were obtained using a dispersive spectrometer (830-nm, 300-mW power, and 20-s accumulation). Spectra were then submitted to principal component analysis (PCA) followed by discriminant analysis. The first PCA loading vectors revealed spectral features of urea, creatinine, and glucose. It has been found that the amounts of urea and creatinine decreased as disease evoluted from CTR to LR/HR and DI (PC1, p<0.05), and the amount of glucose increased in the urine of LR/HR compared to CTR (PC3, p<0.05). The discriminating model showed better overall classification rate of 70%. These results could lead to diagnostic information of possible complications and a better disease prognosis.

  4. Simple DNA extraction of urine samples: Effects of storage temperature and storage time.

    PubMed

    Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong

    2018-06-01

    Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Exploring the concurrent presence of hepatitis A virus genome in serum, stool, saliva, and urine samples of hepatitis A patients.

    PubMed

    Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D

    2014-04-01

    The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Simultaneous quantitation of seven pyrethroid metabolites in human urine by capillary gas chromatography-mass spectrometry.

    PubMed

    Tao, Lin; Chen, Mei; Collins, Erin; Lu, Chensheng

    2013-02-01

    Pyrethroid insecticides are applied in the residential environment, as well as in agricultural crops, for insect control purpose. We developed and validated an accurate, sensitive, and reproducible analytical method to simultaneously detect seven pyrethroid metabolites, namely, 3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, 3-(2,2-dibromovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, 3-phenoxybenzoic acid, 4-fluoro-3-phenoxybenzoic acid, 2-methyl-3-phenylbenzoic acid, 4-chloro-α-isoproply benzeneacetic acid, and 3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, in human urine. This method employs deconjugation with enzyme, SPE using Agilent C18 cartridges on a RapidTrace SPE workstation, derivatization using hexafluoro isopropanol and N,N'-diisopropylcarbodiimide, and compounds separation and identification on GC-MS. The detection limits of seven metabolites were 0.02-0.08 ng/mL in urine. The recoveries of seven metabolites were 81-104%, 85-99%, and 83-99% in urine specimens fortified at 0.1, 0.4, and 3.2 ng/mL concentrations, respectively. The overall coefficient of variation was 4.3-10.8% in two quality control specimens which were repeatedly measured during a period of 2 months. This method was applied to urine samples collected from children living in Boston, MA. The median concentrations of six detected pyrethroid metabolites ranged from 0.06 to 0.86 ng/mL in urine. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Fluid balance, glomerular filtration rate, and urine output in dogs anesthetized for an orthopedic surgical procedure.

    PubMed

    Boscan, Pedro; Pypendop, Bruno H; Siao, Kristine T; Francey, Thierry; Dowers, Kristy; Cowgill, Larry; Ilkiw, Jan E

    2010-05-01

    To determine fluid retention, glomerular filtration rate, and urine output in dogs anesthetized for a surgical orthopedic procedure. 23 dogs treated with a tibial plateau leveling osteotomy. 12 dogs were used as a control group. Cardiac output was measured in 5 dogs, and 6 dogs received carprofen for at least 14 days. Dogs received oxymorphone, atropine, propofol, and isoflurane for anesthesia (duration, 4 hours). Urine and blood samples were obtained for analysis every 30 minutes. Lactated Ringer's solution was administered at 10 mL/kg/h. Urine output was measured and glomerular filtration rate was estimated. Fluid retention was measured by use of body weight, fluid balance, and bioimpedance spectroscopy. No difference was found among control, cardiac output, or carprofen groups, so data were combined. Median urine output and glomerular filtration rate were 0.46 mL/kg/h and 1.84 mL/kg/min. Dogs retained a large amount of fluids during anesthesia, as indicated by increased body weight, positive fluid balance, increased total body water volume, and increased extracellular fluid volume. The PCV, total protein concentration, and esophageal temperature decreased in a linear manner. Dogs anesthetized for a tibial plateau leveling osteotomy retained a large amount of fluids, had low urinary output, and had decreased PCV, total protein concentration, and esophageal temperature. Evaluation of urine output alone in anesthetized dogs may not be an adequate indicator of fluid balance.

  8. European genome-wide association study identifies SLC14A1 as a new urinary bladder cancer susceptibility gene

    PubMed Central

    Rafnar, Thorunn; Vermeulen, Sita H.; Sulem, Patrick; Thorleifsson, Gudmar; Aben, Katja K.; Witjes, J. Alfred; Grotenhuis, Anne J.; Verhaegh, Gerald W.; Hulsbergen-van de Kaa, Christina A.; Besenbacher, Soren; Gudbjartsson, Daniel; Stacey, Simon N.; Gudmundsson, Julius; Johannsdottir, Hrefna; Bjarnason, Hjordis; Zanon, Carlo; Helgadottir, Hafdis; Jonasson, Jon Gunnlaugur; Tryggvadottir, Laufey; Jonsson, Eirikur; Geirsson, Gudmundur; Nikulasson, Sigfus; Petursdottir, Vigdis; Bishop, D. Timothy; Chung-Sak, Sei; Choudhury, Ananya; Elliott, Faye; Barrett, Jennifer H.; Knowles, Margaret A.; de Verdier, Petra J.; Ryk, Charlotta; Lindblom, Annika; Rudnai, Peter; Gurzau, Eugene; Koppova, Kvetoslava; Vineis, Paolo; Polidoro, Silvia; Guarrera, Simonetta; Sacerdote, Carlotta; Panadero, Angeles; Sanz-Velez, José I.; Sanchez, Manuel; Valdivia, Gabriel; Garcia-Prats, Maria D.; Hengstler, Jan G.; Selinski, Silvia; Gerullis, Holger; Ovsiannikov, Daniel; Khezri, Abdolaziz; Aminsharifi, Alireza; Malekzadeh, Mahyar; van den Berg, Leonard H.; Ophoff, Roel A.; Veldink, Jan H.; Zeegers, Maurice P.; Kellen, Eliane; Fostinelli, Jacopo; Andreoli, Daniele; Arici, Cecilia; Porru, Stefano; Buntinx, Frank; Ghaderi, Abbas; Golka, Klaus; Mayordomo, José I.; Matullo, Giuseppe; Kumar, Rajiv; Steineck, Gunnar; Kiltie, Anne E.; Kong, Augustine; Thorsteinsdottir, Unnur; Stefansson, Kari; Kiemeney, Lambertus A.

    2011-01-01

    Three genome-wide association studies in Europe and the USA have reported eight urinary bladder cancer (UBC) susceptibility loci. Using extended case and control series and 1000 Genomes imputations of 5 340 737 single-nucleotide polymorphisms (SNPs), we searched for additional loci in the European GWAS. The discovery sample set consisted of 1631 cases and 3822 controls from the Netherlands and 603 cases and 37 781 controls from Iceland. For follow-up, we used 3790 cases and 7507 controls from 13 sample sets of European and Iranian ancestry. Based on the discovery analysis, we followed up signals in the urea transporter (UT) gene SLC14A. The strongest signal at this locus was represented by a SNP in intron 3, rs17674580, that reached genome-wide significance in the overall analysis of the discovery and follow-up groups: odds ratio = 1.17, P = 7.6 × 10−11. SLC14A1 codes for UTs that define the Kidd blood group and are crucial for the maintenance of a constant urea concentration gradient in the renal medulla and, through this, the kidney's ability to concentrate urine. It is speculated that rs17674580, or other sequence variants in LD with it, indirectly modifies UBC risk by affecting urine production. If confirmed, this would support the ‘urogenous contact hypothesis’ that urine production and voiding frequency modify the risk of UBC. PMID:21750109

  9. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    PubMed

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  10. A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection

    PubMed Central

    Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895

  11. [Effect of the chelator Zn-DTPA on the excretion of lead in lead intoxication mice detected with ICP-MS].

    PubMed

    Li, Chen; Lu, Kai-zhi; Zhou, Qi; Wang, Qiong; Zeng, Yu-liang; Yin, Hong-jun; He, Xuan-hui; Tian, Ying; Dong, Jun-Xing

    2014-11-01

    To study the lead excretion effect of the chelator Zn-DTPA on the lead intoxication mice, inductively coupled plasma mass spectrometry (ICP-MS) was applied to detect the lead content of biological samples. The acute lead intoxication mice model was established by injecting lead acetate intraperitoneally with the dose of 1 mg. Zn-DTPA was administered intraperitoneally to mice once daily for five consecutive days 4 h after intoxication. Control group, model group, combination of Zn-DTPA and Ca-DTPA group were evaluated at the same time. The urine was collected every day. The mice were sacrificed in batches in the 2rd, 4th, 6th day. Biological samples including urine, whole blood, femur and brain were prepared and nitrated. Lead concentration was detected by ICP-MS. The result showed that Zn-DTPA could increase lead content in urine markedly and reduce lead content in blood, femur and brain.

  12. Identification of Unique Blood and Urine Biomarkers in Influenza Virus and Staphylococcus aureus Co-infection: A Preliminary Study.

    PubMed

    Prescott, Meagan A; Pastey, Manoj K

    2010-12-05

    Each year, there are estimated to be approximately 200,000 hospitalizations and 36,000 deaths due to influenza in the United States. Reports have indicated that most deaths are not directly due to influenza virus, but to secondary bacterial pneumonia, predominantly staphylococcal in origin. Here we identify the presence of candidate blood and urine biomarkers in mice with Staphyococcus aureus and influenza virus co-infection. In this pilot study, mice were grouped into four treatments: co-infected with influenza virus and S. aureus, singly infected with influenza virus or S. aureus, and a control group of uninfected mice (PBS treated). Gene expression changes were identified by DNA-microarrays from blood samples taken at day five post infection. Proteomic changes were obtained from urine samples collected at three and five days post infection using 2-D DIGE followed by protein ID by mass spectrometry. Differentially expressed genes and/or proteins were identified as candidate biomarkers for future validation in larger studies.

  13. Reactivation and shedding of cytomegalovirus in astronauts during spaceflight

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Stowe, R. P.; Feiveson, A. H.; Tyring, S. K.; Pierson, D. L.

    2000-01-01

    The reactivation of cytomegalovirus (CMV) in 71 astronauts was investigated, using polymerase chain reaction. A significantly greater (P<.0001) shedding frequency was found in urine samples from astronauts before spaceflight (10.6%) than in urine from the healthy control subject group (1.2%). Two of 4 astronauts studied during spaceflight shed CMV in urine. A significant increase (P<.0001) in CMV antibody titer, compared with baseline values, was also found 10 days before spaceflight. CMV antibody titer was further increased (P<.001) 3 days after landing, compared with 10 days before the mission. Significant increases in stress hormones were also found after landing. These results demonstrate that CMV reactivation occurred in astronauts before spaceflight and indicate that CMV may further reactivate during spaceflight.

  14. Crowdsourcing Disease Biomarker Discovery Research: The IP4IC Study.

    PubMed

    Chancellor, Michael B; Bartolone, Sarah N; Veerecke, Andrew; Lamb, Laura E

    2018-05-01

    Biomarker discovery is limited by readily assessable, cost efficient human samples available in large numbers that represent the entire heterogeneity of the disease. We developed a novel, active participation crowdsourcing method to determine BP-RS (Bladder Permeability Defect Risk Score). It is based on noninvasive urinary cytokines to discriminate patients with interstitial cystitis/bladder pain syndrome who had Hunner lesions from controls and patients with interstitial cystitis/bladder pain syndrome but without Hunner lesions. We performed a national crowdsourcing study in cooperation with the Interstitial Cystitis Association. Patients answered demographic, symptom severity and urinary frequency questionnaires on a HIPAA (Health Insurance Portability and Accountability Act) compliant website. Urine samples were collected at home, stabilized with a preservative and sent to Beaumont Hospital for analysis. The expression of 3 urinary cytokines was used in a machine learning algorithm to develop BP-RS. The IP4IC study collected a total of 448 urine samples, representing 153 patients (147 females and 6 males) with interstitial cystitis/bladder pain syndrome, of whom 54 (50 females and 4 males) had Hunner lesions. A total of 159 female and 136 male controls also participated, who were age matched. A defined BP-RS was calculated to predict interstitial cystitis/bladder pain syndrome with Hunner lesions or a bladder permeability defect etiology with 89% validity. In this novel participation crowdsourcing study we obtained a large number of urine samples from 46 states, which were collected at home, shipped and stored at room temperature. Using a machine learning algorithm we developed BP-RS to quantify the risk of interstitial cystitis/bladder pain syndrome with Hunner lesions, which is indicative of a bladder permeability defect etiology. To our knowledge BP-RS is the first validated urine biomarker assay for interstitial cystitis/bladder pain syndrome and one of the first biomarker assays to be developed using crowdsourcing. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Biological indicators of exposure to total and respirable aluminium dust fractions in a primary aluminium smelter.

    PubMed Central

    Röllin, H B; Theodorou, P; Cantrell, A C

    1996-01-01

    OBJECTIVES: The study attempts to define biological indicators of aluminium uptake and excretion in workers exposed to airborne aluminium compounds in a primary aluminium smelter. Also, this study defines the total and respirable aluminium dust fractions in two different potrooms, and correlates their concentrations with biological indicators in this group of workers. METHODS: Air was sampled at defined work sites. Non-destructive and conventional techniques were used to find total and respirable aluminium content of the dust. Blood and urine was collected from 84 volunteers employed at various work stations throughout the smelter and from two different cohorts of controls matched for sex, age, and socioeconomic status. Aluminium in serum samples and urine specimens was measured by flameless atomic absorption with a PE 4100 ZL spectrometer. RESULTS: The correlation of aluminium concentrations in serum and urine samples with the degree of exposure was assessed for three arbitrary exposure categories; low (0.036 mg Al/m3), medium (0.35 mg Al/m3) and high (1.47 mg Al/m3) as found in different areas of the smelter. At medium and high exposure, the ratio of respirable to total aluminium in the dust samples varied significantly. At high exposure, serum aluminium, although significantly raised, was still within the normal range of an unexposed population. The workers with low exposure excreted aluminium in urine at levels significantly higher than the controls, but still within the normal range of the population. However, potroom workers with medium and high exposure had significantly higher urinary aluminium than the normal range. CONCLUSIONS: It is concluded that only urinary aluminium constitutes a practical index of occupational exposure at or above 0.35 mg Al/m3, and that the respirable fraction of the dust may play a major role in the biological response to exposure to aluminium in a smelter environment. PMID:8758038

  16. Employment-based abstinence reinforcement as a maintenance intervention for the treatment of cocaine dependence: a randomized controlled trial.

    PubMed

    DeFulio, Anthony; Donlin, Wendy D; Wong, Conrad J; Silverman, Kenneth

    2009-09-01

    Due to the chronic nature of cocaine dependence, long-term maintenance treatments may be required to sustain abstinence. Abstinence reinforcement is among the most effective means of initiating cocaine abstinence. Practical and effective means of maintaining abstinence reinforcement programs over time are needed. To determine whether employment-based abstinence reinforcement can be an effective long-term maintenance intervention for cocaine dependence. Participants (n = 128) were enrolled in a 6-month job skills training and abstinence initiation program. Participants who initiated abstinence, attended regularly and developed needed job skills during the first 6 months were hired as operators in a data entry business and assigned randomly to an employment-only (control, n = 24) or abstinence-contingent employment (n = 27) group. A non-profit data entry business. Participants Unemployed welfare recipients who used cocaine persistently while enrolled in methadone treatment in Baltimore. Abstinence-contingent employment participants received 1 year of employment-based contingency management, in which access to employment was contingent upon provision of drug-free urine samples under routine and then random drug testing. If a participant provided drug-positive urine or failed to provide a mandatory sample, then that participant received a temporary reduction in pay and could not work until urinalysis confirmed recent abstinence. Cocaine-negative urine samples at monthly assessments across 1 year of employment. During the 1 year of employment, abstinence-contingent employment participants provided significantly more cocaine-negative urine samples than employment-only participants [79.3% and 50.7%, respectively; P = 0.004, odds ratio (OR) = 3.73, 95% confidence interval (CI) = 1.60-8.69]. Conclusions Employment-based abstinence reinforcement that includes random drug testing is effective as a long-term maintenance intervention, and is among the most promising treatments for drug dependence. Work-places could serve as therapeutic agents in the treatment of drug dependence by arranging long-term employment-based contingency management programs.

  17. Increased levels of oxidative DNA damage attributable to cooking-oil fumes exposure among cooks.

    PubMed

    Ke, Yuebin; Cheng, Jinquan; Zhang, Zhicheng; Zhang, Renli; Zhang, Zhunzhen; Shuai, Zhihong; Wu, Tangchun

    2009-07-01

    Previous investigations have indicated that cooks are exposed to polycyclic aromatic hydrocarbons (PAHs) from cooking-oil fumes. However, Emission of PAH and their carcinogenic potencies from cooking oil fumes sources have not been investigated among cooks. To investigate the urinary excretion of a marker for oxidative DNA damage, 8-hydroxydeoxyguanosine (8-OHdG), in different groups of cooks and different exposure groups, and to study the association between 8-OHdG and 1-hydroxypyrene(1-OHP), a biological marker for PAH exposure. Urine samples were collected from different groups of cooks (n = 86) and from unexposed controls (n = 36); all were male with similar age and smoking habits. The health status, occupational history, smoking, and alcohol consumption 24 h prior to sampling was estimated from questionnaires. The urine samples were frozen for later analyses of 8-OHdG and 1-OHP levels by high-performance liquid chromatography. Excretion in urine of 8-OHdG was similar for controls (mean 1.2micromol/mol creatinine, n = 36), and for those who had been in the kitchen with an exhaust-hood operating (mean 1.5micromol/mol creatinine, n = 45). Cooks exposed to cooking-oil fumes without exhaust-hood operation had significantly increased excretion of 8-OHdG (mean 2.3micromol/mol creatinine, n = 18), compared with controls. The urinary levels of ln 1-OHP and ln 8-OHdG were still significantly correlated in a multiple regression analysis. The results indicate that exposure to PAH or possibly other compounds in cooking-oil fumes may cause oxidative DNA damage.

  18. Mercury Exposure among Garbage Workers in Southern Thailand

    PubMed Central

    2012-01-01

    Objectives 1) To determine mercury levels in urine samples from garbage workers in Southern Thailand, and 2) to describe the association between work characteristics, work positions, behavioral factors, and acute symptoms; and levels of mercury in urine samples. Methods A case-control study was conducted by interviewing 60 workers in 5 hazardous-waste-management factories, and 60 matched non-exposed persons living in the same area of Southern Thailand. Urine samples were collected to determine mercury levels by cold-vapor atomic absorption spectrometer mercury analyzer. Results The hazardous-waste workers' urinary mercury levels (10.07 µg/g creatinine) were significantly higher than the control group (1.33 µg/g creatinine) (p < 0.001). Work position, duration of work, personal protective equipment (PPE), and personal hygiene, were significantly associated with urinary mercury level (p < 0.001). The workers developed acute symptoms - of headaches, nausea, chest tightness, fatigue, and loss of consciousness at least once a week - and those who developed symptoms had significantly higher urinary mercury levels than those who did not, at p < 0.05. A multiple regression model was constructed. Significant predictors of urinary mercury levels included hours worked per day, days worked per week, duration of work (years), work position, use of PPE (mask, trousers, and gloves), and personal hygiene behavior (ate snacks or drank water at work, washed hands before lunch, and washed hands after work). Conclusion Changing garbage workers' hygiene habits can reduce urinary mercury levels. Personal hygiene is important, and should be stressed in education programs. Employers should institute engineering controls to reduce urinary mercury levels among garbage workers. PMID:23251842

  19. Jet Fuel Exposure and Neurological Health in Military Personnel

    DTIC Science & Technology

    2011-07-01

    and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples

  20. The examination of urine samples for pathogenic microbes by the luciferase assay for ATP. 1: The effect of the presence of fungi, fungal like bacteria and kidney cells in urine samples

    NASA Technical Reports Server (NTRS)

    Bush, V. N.

    1973-01-01

    A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.

  1. Diuretic activity and toxicity study of the aqueous extract of Cola nitida seed on markers of renal function and electrolytes in rats.

    PubMed

    Nnemdi Ashibuogwu, Mirian; Isaac Adeosun, Olukayode; Ojo Akomolafe, Rufus; Olaniyi Sanni, Douglas; Sesan Olukiran, Olaoluwa

    2016-12-01

    BackgroundCola nitida is a plant, conventionally used in Africa in the treatment of various ailments such as migraine, morning sickness and indigestion. The aim of the present study was to explore the diuretic activity of the aqueous extract of C. nitida seed (AECONS) and alteration caused by its subchronic administration on the structure and function of the kidney of male Wistar rats. MethodsThe study was divided into diuretic and subchronic studies. Twenty-five male Wistar rats weighing between 140 and 180 g were divided into five groups of five rats each. The first 24 h of this study investigated the possible diuretic activity of C. nitida seed. Group I (the control) received 25 mL/kg of normal saline. Group II (the standard) received 20 mg/kg/day of furosemide. Groups III, IV, V received 400, 600 and 800 mg/kg/day of AECONS, respectively, and orally. Urine volume, pH, specific gravity and electrolytes were estimated in the samples of urine collected after 6 h of the study. From the second day onward and up to a period of 4 weeks, the rats in each group were given normal saline, furosemide and AECONS once daily as was done on the first day. At the end of the 4-week treatment period, blood and urine samples were collected for the determination of creatinine, urea, Na+, K+ and Cl- concentrations. Results The results of the diuretic study showed that the AECONS at all doses used and furosemide produced a significant increase in urine output with respect to the control group. AECONS also induced a significant increase in the urine concentrations of Na+, K+, Cl- in the experimental and standard groups when compared with the control group, except for group III which showed no significant variation in K+ concentration. In the subchronic study, AECONS caused a significant increase in the urine levels of Na+, K+, Cl- in the experimental and standard groups when compared with the control rats. The plasma Na+ concentration of groups IV and V was significantly lower than that of the control group. Photomicrographs of the kidneys of the experimental and standard groups revealed no significant alterations in the histology of their kidney tissues. Conclusions It is concluded that AECONS induced diuresis which is associated with increased Na+, K+ and Cl- loss in rats without any significant alteration in the structure of their kidneys.

  2. Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2014-06-10

    Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES

    EPA Science Inventory

    Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...

  4. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    NASA Technical Reports Server (NTRS)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  5. Diversity of the midstream urine microbiome in adults with chronic kidney disease.

    PubMed

    Kramer, Holly; Kuffel, Gina; Thomas-White, Krystal; Wolfe, Alan J; Vellanki, Kavitha; Leehey, David J; Bansal, Vinod K; Brubaker, Linda; Flanigan, Robert; Koval, Julia; Wadhwa, Anuradha; Zilliox, Michael J

    2018-06-01

    To examine the characteristics of the midstream urine microbiome in adults with stage 3-5 non-dialysis-dependent chronic kidney disease (CKD). Patients with non-dialysis-dependent CKD (estimated glomerular filtration rate [eGFR] < 60 ml/min/1.73 m 2 ) and diuretic use were recruited from outpatient nephrology clinics. Midstream voided urine specimens were collected using the clean-catch method. The bacterial composition was determined by sequencing the hypervariable (V4) region of the bacterial 16S ribosomal RNA gene. Extraction negative controls (no urine) were included to assess the contribution of extraneous DNA from possible sources of contamination. Midstream urine microbiome diversity was assessed with the inverse Simpson, Chao and Shannon indices. The diversity measures were further examined by demographic characteristics and by comorbidities. The cohort of 41 women and 36 men with detectable bacterial DNA in their urine samples had a mean age of 71.5 years (standard deviation [SD] 7.9) years (range 60-91 years). The majority were white (68.0%) and a substantial minority were African-American (29.3%) The mean eGFR was 27.2 (SD 13.6) ml/min/1.73 m 2 . Most men (72.2%) were circumcised and 16.6% reported a remote history of prostate cancer. Many midstream voided urine specimens were dominated (> 50% reads) by the genera Corynebacterium (n = 11), Staphylococcus (n = 9), Streptococcus (n = 7), Lactobacillus (n = 7), Gardnerella (n = 7), Prevotella (n = 4), Escherichia_Shigella (n = 3), and Enterobacteriaceae (n = 2); the rest lacked a dominant genus. The samples had high levels of diversity, as measured by the inverse Simpson [7.24 (95% CI 6.76, 7.81)], Chao [558.24 (95% CI 381.70, 879.35)], and Shannon indices [2.60 (95% CI 2.51, 2.69)]. Diversity measures were generally higher in participants with urgency urinary incontinence and higher estimated glomerular filtration rate (eGFR). After controlling for demographics and diabetes status, microbiome diversity was significantly associated with estimated eGFR (P < 0.05). The midstream voided urine microbiome of older adults with stage 3-5 non-dialysis-dependent CKD is diverse. Greater microbiome diversity is associated with higher eGFR.

  6. Latent Virus Reactivation in Space Shuttle Astronauts

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Crucian, B. E.; Stowe, R. P.; Sams, C.; Castro, V. A.; Pierson, D. L.

    2011-01-01

    Latent virus reactivation was measured in 17 astronauts (16 male and 1 female) before, during, and after short-duration Space Shuttle missions. Blood, urine, and saliva samples were collected 2-4 months before launch, 10 days before launch (L-10), 2-3 hours after landing (R+0), 3 days after landing (R+14), and 120 days after landing (R+120). Epstein-Barr virus (EBV) DNA was measured in these samples by quantitative polymerase chain reaction. Varicella-zoster virus (VZV) DNA was measured in the 381 saliva samples and cytomegalovirus (CMV) DNA in the 66 urine samples collected from these subjects. Fourteen astronauts shed EBV DNA in 21% of their saliva samples before, during, and after flight, and 7 astronauts shed VZV in 7.4% of their samples during and after flight. It was interesting that shedding of both EBV and VZV increased during the flight phase relative to before or after flight. In the case of CMV, 32% of urine samples from 8 subjects contained DNA of this virus. In normal healthy control subjects, EBV shedding was found in 3% and VZV and CMV were found in less than 1% of the samples. The circadian rhythm of salivary cortisol measured before, during, and after space flight did not show any significant difference between flight phases. These data show that increased reactivation of latent herpes viruses may be associated with decreased immune system function, which has been reported in earlier studies as well as in these same subjects (data not reported here).

  7. Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection.

    PubMed

    Makrlíková, Anna; Opekar, František; Tůma, Petr

    2015-08-01

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  9. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  10. Temporal variability of urinary cadmium in spot urine samples and first morning voids.

    PubMed

    Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R

    2017-05-01

    Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.

  11. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  12. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    PubMed

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  13. Can nail, hair and urine be used for biomonitoring of human exposure to perfluorooctane sulfonate and perfluorooctanoic acid?

    PubMed

    Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning

    2013-03-01

    Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Virulence factors of Candida species isolated from patients with urinary tract infection and obstructive uropathy

    PubMed Central

    Alenzi, Faris Q.B.

    2016-01-01

    Objective: Fungal urinary tract infections due to Candida have increased significantly in recent years. Our research objective was to study Candida species in urine samples of patients with urinary tract infections (UTIs) associated with obstructive uropathy and to investigate the virulence factors of the isolated Candida. Methods: Patients were divided into two groups: Group I (cases): 50 patients with UTIs and obstructive uropathy. Group II (control): 50 patients with UTIs but with no functional or anatomical obstruction of their urinary tract. Clinical histories and physical examinations, together with laboratory investigations of urine samples were carried out in all patients in this study. Mid stream urine samples were examined microscopically and by fungal cell culture. The isolated Candida species were identified by analytical profile index (API). Candida Virulence factors were determined for the isolated Candida. The susceptibility to fluconazole was evaluated. Results: This study revealed an overall isolation rate of 27% of Candida species among all patient groups. The rate was 36% in cases, and 18% in controls, a difference found to be statistically significant (P<0.05). By API, C.albicans was detected in 44% of Candida species in cases, and in 33% in controls. While C.glabrata was detected in 28% of Candida species in cases, and in 22% in controls. C.tropicalis was detected in 17% of Candida species in cases, and in 22% in controls. Both C.krusei and C.kyfr were detected in 5.5% of Candida species in cases, and in 11% in controls. In terms of virulence factors the study showed that 11 out of 27 (40.5%) of Candida isolates were biofilm positive by tube adherence. Phospholipase activity was demonstrated in 12 out of 27 (44.5%) of Candida isolates. Secretory aspartic proteinase activity was demonstrated in 13 out of 27 (48%) of the Candida isolates. Conclusion: Candida is an important cause of UTIs and obstructive uropathy is a major predisposing factor. PMID:27022363

  15. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  16. Detection And Identification Of Inflammatory Bowel Disease Electronic Nose

    NASA Astrophysics Data System (ADS)

    Covington, J. A.; Ouaret, N.; Gardner, J. W.; Nwokolo, C.; Bardhan, K. D.; Arasaradnam, R. P.

    2011-11-01

    Inflammatory bowel disease (IBD) is an inflammation of the lining of the human bowel and a major health issue in Europe. IBD carries with it significant morbidity from toxic treatment, surgery and a risk of developing bowel cancer. Thus there is a need for early identification of the disease using non-invasive tests. Present diagnostic techniques are based around invasive tests (i.e. endoscopy) and laboratory culture; the latter is limited as only 50% of the gut bacteria can be identified. Here we explore the use of an e-nose as a tool to detect and identify two IBDs (i.e. Crohn's disease (CD) & Ulcerative Colitis (UC)) based on headspace analysis from urine samples. We believe that the gut bacterial flora is altered by disease (due to fermentation) that in-turn modulates the gas composition within urine samples. 24 samples (9 CD, 6 UC, 9 controls) were analysed with an in-house e-nose and an Owlstone IMS instrument. Data analysis was performed using linear discriminant analysis (LDA and principal components analysis (PCA). Using the e-nose, LDA separates both disease groups and control, whilst PCA shows a small overlap of classes. The IMS data are more complex but shows some disease/control separation. We are presently collecting further samples for a larger study using more advanced data processing methods.

  17. NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...

  18. NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...

  19. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    PubMed

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  20. Distribution of copper, iron, and zinc in biological samples (scalp hair, serum, blood, and urine) of Pakistani viral hepatitis (A-E) patients and controls.

    PubMed

    Kolachi, Nida Fatima; Kazi, Tasneem Gul; Afridi, Hassan Imran; Kazi, Naveed; Kandhro, Ghulam Abbas; Shah, Abdul Qadir; Baig, Jameel Ahmed; Wadhwa, Sham Kumar; Khan, Sumaira; Shah, Faheem; Jamali, Mohammad Khan; Arain, Mohammad Balal

    2011-10-01

    The aim of the present study was to compare the level of copper (Cu), iron (Fe) and zinc (Zn) in biological samples (serum, blood, urine, and scalp hair) of patients suffering from different viral hepatitis (A, B, C, D, and E; n = 521) of both gender age ranged 31-45 years. For comparative study, 255 age-matched control subjects, of both genders residing in the same city were selected as referents. The elements in the biological samples were analyzed by flame atomic absorption spectrophotometry, prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cu and Fe were higher in blood, sera, and scalp hair samples of hepatitis patients, while Zn level was found to be lower than age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p < 0.05). These results are consistent with literature-reported data, confirming that the deficiency of zinc and hepatic iron and copper overload can directly cause lipid peroxidation and eventually hepatic damage.

  1. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    PubMed

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  2. Detection of Novel Visible-Light Region Absorbance Peaks in the Urine after Alkalization in Patients with Alkaptonuria

    PubMed Central

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168

  3. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  4. Diagnostic utility and cost-effectiveness of reflex bacterial culture for the detection of urinary tract infection in dogs with low urine specific gravity.

    PubMed

    Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M

    2009-09-01

    Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.

  5. Chronic stress and calcium oxalate stone disease: influence on blood cortisol and urine composition.

    PubMed

    Arzoz-Fàbregas, Montserrat; Ibarz-Servio, Luis; Fernández-Castro, Jordi; Valiente-Malmagro, Manuel; Roca-Antonio, Josep; Edo-Izquierdo, Sílvia; Buisan-Rueda, Oscar

    2013-12-01

    To evaluate the influence of chronic stress (CS) on urine composition of calcium oxalate (CaOx) stone patients and controls. This case-control study enrolled 128 patients during a period of 20 months. The cases were CaOx stone formers with a recent stone episode. Controls were matched by sex and age. Dimensions of CS were evaluated in cases and controls by validated self-report questionnaires measuring stressful life events, perceived stress, anxiety, depression, burnout, and satisfaction with life. Blood and urine samples were collected to determine cortisol levels and urinary composition. More relations between CS dimensions and blood and urine parameters were observed in cases than in controls. In cases, the blood cortisol level was related positively with the number of stressful life events (P = .03), intensity of these events (P = .04), and anxiety (P = .04). In addition, urinary magnesium (P = .03) and pyrophosphate (P = .05) levels were positively related with satisfaction with life and burnout, respectively. In contrast, urinary magnesium levels were negatively related with perceived stress (P = .01), anxiety (P = .016), and depression (P = .03). In controls, the number of stressful life events and the intensity of stressful life events was related positively with magnesium (P = .06, P = .02) levels and negatively with blood cortisol levels (P = .03, P = .004). Based on the variation between cases and controls in relations between CS dimensions and biochemical parameters, we hypothesize that CS may trigger a differential biological response in CaOx stone formers and controls, which in turn may promote or protect against CaOx stone formation. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  7. Comparison of osmolality and refractometric readings of Hispaniolan Amazon parrot (Amazona ventralis) urine.

    PubMed

    Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W

    2013-12-01

    To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.

  8. Pyrazine Analogues Are Active Components of Wolf Urine That Induce Avoidance and Freezing Behaviours in Mice

    PubMed Central

    Osada, Kazumi; Kurihara, Kenzo; Izumi, Hiroshi; Kashiwayanagi, Makoto

    2013-01-01

    Background The common grey wolf (Canis lupus) is found throughout the entire Northern hemisphere and preys on many kinds of mammals. The urine of the wolf contains a number of volatile constituents that can potentially be used for predator–prey chemosignalling. Although wolf urine is put to practical use to keep rabbits, rodents, deer and so on at bay, we are unaware of any prior behavioural studies or chemical analyses regarding the fear-inducing impact of wolf urine on laboratory mice. Methodology/Principal Findings Three wolf urine samples harvested at different times were used in this study. All of them induced stereotypical fear-associated behaviors (i.e., avoidance and freezing) in female mice. The levels of certain urinary volatiles varied widely among the samples. To identify the volatiles that provoked avoidance and freezing, behavioural, chemical, and immunohistochemical analyses were performed. One of the urine samples (sample C) had higher levels of 2,6-dimethylpyrazine (DMP), trimethylpyrazine (TMP), and 3-ethyl-2,5-dimethyl pyrazine (EDMP) compared with the other two urine samples (samples A and B). In addition, sample C induced avoidance and freezing behaviours more effectively than samples A and B. Moreover, only sample C led to pronounced expression of Fos-immunoreactive cells in the accessory olfactory bulb (AOB) of female mice. Freezing behaviour and Fos immunoreactivity were markedly enhanced when the mice were confronted with a mixture of purified DMP, TMP, and EDMP vs. any one pyrazine alone. Conclusions/Significance The current results suggest that wolf urinary volatiles can engender aversive and fear-related responses in mice. Pyrazine analogues were identified as the predominant active components among these volatiles to induce avoidance and freezing behaviours via stimulation of the murine AOB. PMID:23637901

  9. NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...

  10. Urinary ATP May Be a Dynamic Biomarker of Detrusor Overactivity in Women with Overactive Bladder Syndrome

    PubMed Central

    Oliveira, Olga; Ferreira, Sónia; Reis, Maria Júlia; Oliveira, José Carlos; Correia-de-Sá, Paulo

    2013-01-01

    Background Nowadays, there is a considerable bulk of evidence showing that ATP has a prominent role in the regulation of human urinary bladder function and in the pathophysiology of detrusor overactivity. ATP mediates nonadrenergic-noncholinergic detrusor contractions in overactive bladders. In vitro studies have demonstrated that uroepithelial cells and cholinergic nerves from overactive human bladder samples (OAB) release more ATP than controls. Here, we compared the urinary ATP concentration in samples collected non-invasively from OAB women with detrusor overactivity and age-matched controls. Methods Patients with neurologic diseases, history of malignancy, urinary tract infections or renal impairment (creatinine clearance <70 ml/min) were excluded. All patients completed a 3-day voiding diary, a 24 h urine collection and blood sampling to evaluate creatinine clearance. Urine samples collected during voluntary voids were immediately freeze-preserved for ATP determination by the luciferin-luciferase bioluminescence assay; for comparison purposes, samples were also tested for urinary nerve growth factor (NGF) by ELISA. Results The urinary content of ATP, but not of NGF, normalized to patients’ urine creatinine levels (ATP/Cr) or urinary volume (ATP.Vol) were significantly (P<0.05) higher in OAB women with detrusor overactivity (n = 34) than in healthy controls (n = 30). Significant differences between the two groups were still observed by boosting urinary ATP/Cr content after water intake, but these were not detected for NGF/Cr. In OAB patients, urinary ATP/Cr levels correlated inversely with mean voided volumes determined in a 3-day voiding diary. Conclusion A high area under the receiver operator characteristics (ROC) curve (0.741; 95% CI 0.62–0.86; P<0.001) is consistent with urinary ATP/Cr being a highly sensitive dynamic biomarker for assessing detrusor overactivity in women with OAB syndrome. PMID:23741373

  11. Exposure to 4,4'-methylenediphenyl diisocyanate (MDI) during moulding of rigid polyurethane foam: determination of airborne MDI and urinary 4,4'-methylenedianiline (MDA).

    PubMed

    Kääriä, K; Hirvonen, A; Norppa, H; Piirilä, P; Vainio, H; Rosenberg, C

    2001-04-01

    Occupational exposure to 4,4'-methylenediphenyl diisocyanate (MDI) was measured during moulding of rigid polyurethane foam. The aim of the study was to find out whether an MDI-derived urinary amine metabolite could be detected in the urine of workers exposed to apparently low levels of MDI. Airborne MDI was sampled on 1-(2-methoxyphenyl)-piperazine (2MP)-impregnated glass fibre filters and determined by high-performance liquid chromatography (HPLC) using ultraviolet (UV) and electrochemical (EC) detection. The limit of detection of MDI was 3 ng ml-1 for a 20 microliters injection. The precision of sample preparation, expressed as relative standard deviation (RSD), was 1.3% with UV detection and 2.1% with EC detection at a concentration of 70 ng MDI ml-1 (n = 6). The 2MP-MDI derivative was stable at +4 degrees C up to eight weeks. The accuracy of the method was validated in an international quality control programme. Workers (n = 57) from three different factories participated in the study. Urinary 4,4'-methylenedianiline (MDA) metabolite was determined after acid hydrolysis as heptafluorobutyric anhydride derivatives by gas chromatography-mass spectrometry using chemical ionisation and monitoring negative ions. The limit of detection in urine was 0.2 nmol l-1. The precision of six analyses for a urine sample spiked to a concentration of 1 nmol l-1 was 29% (RSD). The MDI concentrations were below the limit of detection in most (64%) of the air samples collected in the worker's breathing zone. Still, detectable amounts of MDA were found in 97% of the urine samples. Monitoring of urinary MDA appears to be an appropriate method of assessing MDI exposure in work environments with low or undetectable MDI concentrations in the workplace air.

  12. Evaluation of NGAL TestTM on Cobas 6000.

    PubMed

    Hansen, Young B L; Damgaard, Anette; Poulsen, Jørgen H

    2014-01-01

    Neutrophil Gelatinase-Associated Lipocalin (NGAL) is a promising biomarker for acute kidney injury (AKI). Our objectives were to evaluate the NGAL Test(TM) from Bioporto for both urine NGAL and plasma NGAL on the Cobas 6000 c501 (Roche Diagnostics, Rotkreuz, Switzerland) with matched measurements run on Hitachi 917, the method's linearity on the Cobas 6000 in urine, EDTA and Lithium-Heparin (Li-Hep), the influence of using EDTA or Li-Hep tubes and, finally, the impact of freezing and thawing on the sample. Forty matched samples of Li-Hep and EDTA plasma and 40 urine samples were analyzed for method, anticoagulant, and freeze-thaw comparisons. Linearity was assessed using high NGAL samples diluted in urine, EDTA, and Li-Hep plasma. Commercial internal controls were used for the imprecision study. The Cobas 6000 measured identically with the Hitachi 917, however, not in EDTA plasma (Median Difference = 17.50 μg/L, p < 0.0001). Freeze-thaw process reduced NGAL ((EDTA: Mean Difference = = 15.13 μg/L, p = 0.0014)(Li-Hep: Median Difference = = 6.5 μg/L, p = 0.0129)). NGAL results were higher in Li-Hep plasma than in EDTA plasma ((Non-thawed: Median Difference = = 14.5 μg/L, p < 0.0001), (Thawed: Median Difference = = 21.5 μg/L, p = 0.0003)). Linearity agreements were observed in all three specimens. Imprecision (CV%) was below 3%. The NGAL Test(TM) can be applied on the Cobas 6000 with acceptable performance, although the Cobas 6000 measured higher than the Hitachi 917 in EDTA plasma. Though clinically insignificant, we found that the freeze-thaw process had a reduced effect. NGAL results were higher in Li-Hep tubes than in EDTA tubes. Thus, for blood samples we recommend use of EDTA tubes for NGAL measurements.

  13. Effect of vitamin C and E supplementation on total antioxidant content of human breastmilk and infant urine.

    PubMed

    Zarban, Asghar; Toroghi, Mahsa Mostafavi; Asli, Marziye; Jafari, Masumeh; Vejdan, Morteza; Sharifzadeh, Gholamreza

    2015-05-01

    After delivery and birth, mothers and neonates are exposed to oxidative stress. The present study examined the effect of supplementation of the diet of breastfeeding mothers with vitamin C and E to improve the antioxidant content of breastmilk and evidence of antioxidant activity in infant urine. The subjects were 60 healthy lactating breastfeeding mothers and their infants 1-6 months of age. They were randomly allocated to a control group (n=30) consuming a free diet or an experimental group (n=30) consuming a free diet supplemented each day with effervescent tablets of vitamin C (500 mg) and chewable tablets of vitamin E (100 IU). After 30 days, the total antioxidant content of the mothers' breastmilk and evidence of antioxidant activity in the infants' urine were measured by the ferric reducing/antioxidant power assay. The free radical scavenging activity of the urine samples was measured by the α,α-diphenyl-β-picrylhydrazyl method. Differences pre- and postintervention were compared within and between the groups. Significantly higher levels of antioxidants in the breastmilk (610±295.5 to 716±237.5 μmol/L) and infant urine (43.2±21.8 to 75.0±49.2 μmol/mg creatinine) were observed in the experimental group over the control group (p<0.05). A significant increase in evidence of free radical scavenging in infant urine was observed in the experimental group after 30 days of supplementation by mothers (p<0.05). Consumption of vitamin C and E supplements appears to have a positive effect on total antioxidant content of breastmilk and evidence of antioxidant activity in infant urine.

  14. Immunization alters body odor.

    PubMed

    Kimball, Bruce A; Opiekun, Maryanne; Yamazaki, Kunio; Beauchamp, Gary K

    2014-04-10

    Infections have been shown to alter body odor. Because immune activation accompanies both infection and immunization, we tested the hypothesis that classical immunization might similarly result in the alteration of body odors detectable by trained biosensor mice. Using a Y-maze, we trained biosensor mice to distinguish between urine odors from rabies-vaccinated (RV) and unvaccinated control mice. RV-trained mice generalized this training to mice immunized with the equine West Nile virus (WNV) vaccine compared with urine of corresponding controls. These results suggest that there are similarities between body odors of mice immunized with these two vaccines. This conclusion was reinforced when mice could not be trained to directly discriminate between urine odors of RV- versus WNV-treated mice. Next, we trained biosensor mice to discriminate the urine odors of mice treated with lipopolysaccharide (LPS; a general elicitor of innate immunological responses) from the urine of control mice. These LPS-trained biosensors could distinguish between the odors of LPS-treated mouse urine and RV-treated mouse urine. Finally, biosensor mice trained to distinguish between the odors of RV-treated mouse urine and control mouse urine did not generalize this training to discriminate between the odors of LPS-treated mouse urine and control mouse urine. From these experiments, we conclude that: (1) immunization alters urine odor in similar ways for RV and WNV immunizations; and (2) immune activation with LPS also alters urine odor but in ways different from those of RV and WNV. Published by Elsevier Inc.

  15. Bladder Control Problems in Men

    MedlinePlus

    ... professional’s office, or at a commercial facility. A health care professional tests the sample during an office visit or sends ... bladder and urethra store and release urine. A health care professional performs urodynamic tests during an office visit or in an outpatient ...

  16. Molecularly imprinted polymer microspheres prepared by Pickering emulsion polymerization for selective solid-phase extraction of eight bisphenols from human urine samples.

    PubMed

    Yang, Jiajia; Li, Yun; Wang, Jincheng; Sun, Xiaoli; Cao, Rong; Sun, Hao; Huang, Chaonan; Chen, Jiping

    2015-05-04

    The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption-desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30-60 μm), a specific surface area (S(BET)) of 281.26 m(2) g(-1) and a total pore volume (V(t)) of 0.459 cm(3) g(-1). Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2-2.2 ng mL(-1). The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL(-1) for each BP) were in the range of 81.3-106.7% with RSD values below 8.3%. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Urinary shedding of pathogenic Leptospira in stray dogs and cats, Algiers: A prospective study.

    PubMed

    Zaidi, Sara; Bouam, Amar; Bessas, Amina; Hezil, Djamila; Ghaoui, Hicham; Ait-Oudhia, Khatima; Drancourt, Michel; Bitam, Idir

    2018-01-01

    Leptospirosis is an important worldwide zoonosis. This disease is caused by pathogenic species of the genus Leptospira which are maintained in the environment via chronic renal infection of carrier animals which can be asymptomatic excretors of the organisms in their urines and become a source of infection for humans and other hosts. The prevalence of animal leptospirosis in Algiers, Algeria, is unknown. Real-time PCR and standard PCR and sequencing were used to detect pathogenic Leptospira organisms in the urines of stray dogs and cats in Algiers. In the presence of appropriate controls, none of the 107 cat urine samples were positive while 5/104 (4.8%) canine urine samples (asymptomatic mixed-breed dogs, three females and two males) were positive in two real-time PCR assays targeting the rrs and hsp genes. The positivity of these samples was confirmed by partial PCR-sequencing of the rpoB gene which yielded 100% sequence similarity with Leptospira interrogans reference sequence. In this study, L. interrogans prevalence was significantly higher in dogs aged < one year (16.46% - 29.41%) than in adults (0%) (P value = 0.0001) and then in the overall dog population (2.68% - 4.8%) (P = 0.0007). These results suggest that dogs are maintenance hosts for zoonotic leptospirosis in Algiers, Algeria. To face this situation, effective canine vaccination strategies and raising public health awareness are mandatory. Further investigations incorporating a larger sample in more localities will be undertaken to document the epidemiology of urban animal leptospirosis in Algeria at large.

  18. Inappropriate phosphate excretion in idiopathic hypercalciuria: the key to a common cause and future treatment?

    PubMed Central

    Williams, C P; Child, D F; Hudson, P R; Soysa, L D; Davies, G K; Davies, M G; De Bolla, A R

    1996-01-01

    AIMS: To present experimental evidence in support of a proposed common cause for absorptive hypercalciuria, renal hypercalciuria, renal phosphate leak and enhancement of 1,25-(OH)2-vitamin D concentrations in patients presenting with renal stone disease; and to suggest further investigation with a view to new management. METHODS: An oral calcium loading test was administered to 15 patients with renal stones and 10 normal controls in the fasting state: urine and blood were collected hourly. After the second urine sample, 400 mg calcium dissolved in water was administered orally. Serum calcium, albumin, parathyroid hormone (PTH), and phosphate were measured together with urine calcium clearance and urinary phosphate from which the TmPO4/glomerular filtration rate (GFR) ratio was calculated. Serum 1,25-(OH)2-vitamin D was measured in the first serum sample. In addition, 24 hour urine calcium results were collected retrospectively from the patients' case notes over the previous 18 months. RESULTS: In the basal state, renal stone patients had an overall greater phosphaturia (lower TmPO4/GFR: median 1.72 compared with 2.10 in controls) and increased calcium clearance. Serum corrected calcium and PTH concentrations did not differ between the groups. After calcium loading, serum calcium and urine calcium clearance rose in both groups, with patients with renal stones experiencing a greater percentage fall in phosphaturia. In both groups TmPO4/GFR fell (greater phosphaturia) with increased serum corrected calcium, with the patients showing notably greater phosphaturia for any given calcium concentration. Patients also had notably greater phosphaturia compared with the serum calcium concentration for any given PTH value. Serum 1,25-(OH)2-vitamin D was higher in patients than controls and for any 1,25-(OH)2-vitamin D concentration phosphaturia measured against serum calcium was greater in patients than controls. 1,25-(OH)2-vitamin D did not correlate with phosphaturia relative to serum calcium concentrations within the patient and control groups. CONCLUSIONS: It is proposed that patients with idiopathic hypercalciuria have an "inappropriately' high phosphate excretion for any given serum calcium concentration. Loss of phosphate may induce increased activation of 1,25-(OH)2-vitamin D. Some of the commonly described causes of stone formation may be manifestations of a single mechanism. PMID:8944605

  19. Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

    NASA Astrophysics Data System (ADS)

    Liu, Ping; Qi, Chu-Bo; Zhu, Quan-Fei; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-02-01

    Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1-11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines.

  20. Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

    PubMed Central

    Liu, Ping; Qi, Chu-Bo; Zhu, Quan-Fei; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-01-01

    Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines. PMID:26888486

  1. DNA damage in children with obstructive adenotonsillar hypertrophy.

    PubMed

    Yoruk, Ozgur; Alp, Hakan; Yuksel, Sancak; Bakan, Ebubekir

    2014-11-01

    The objective of this prospective, controlled study was to evaluate oxidative DNA damage in children with obstructive adenotonsillar hypertrophy. This study included 30 patients with obstructive adenotonsillar hypertrophy (male/female ratio, 3:2; age range, 3-9 y) scheduled to undergo tonsillectomy and adenoidectomy and 25 control subjects of similar age and sex with no adenotonsillar disease or airway obstruction. Urine and blood samples were obtained from each child for 8-hydroxy 2-deoxyguanosine (8-OhdG) and malondialdehyde (MDA) concentrations. There were significant differences in leukocyte (3.28 [0.69/10] vs 0.70 [0.15/10] dG) and urine 8-OhdG (8.22 [2.27/10] vs 5.26 [1.3/10] dG) levels in patients with obstructive adenotonsillar hypertrophy and healthy subjects (P < 0.001 for both). Plasma (2.98 [1.31] vs 1.14 [0.64] μM) and urine (1.77 [0.84] vs 0.56 [0.32] μM) MDA levels were also different (P < 0.001 for both). There were positive correlations between 8-OhdG in leukocyte DNA and plasma MDA (r = 0.648, P < 0.001) and between levels of urine 8-OhdG excretion and urine MDA (r = 0.588, P < 0.001). The DNA damage in children with adenotonsillar hypertrophy should be kept in mind, but further studies must be done with larger patient groups.

  2. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples

    PubMed Central

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170

  3. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  4. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  5. Urinary metabolic insights into host-gut microbial interactions in healthy and IBD children

    PubMed Central

    Martin, Francois-Pierre; Su, Ming-Ming; Xie, Guo-Xiang; Guiraud, Seu Ping; Kussmann, Martin; Godin, Jean-Philippe; Jia, Wei; Nydegger, Andreas

    2017-01-01

    AIM To identify metabolic signatures in urine samples from healthy and inflammatory bowel disease (IBD) children. METHODS We applied liquid chromatography and gas chromatography coupled to targeted mass spectrometry (MS)-based metabolite profiling to identify and quantify bile acids and host-gut microbial metabolites in urine samples collected from 21 pediatric IBD patients monitored three times over one year (baseline, 6 and 12 mo), and 27 age- and gender-matched healthy children. RESULTS urinary metabolic profiles of IBD children differ significantly from healthy controls. Such metabolic differences encompass central energy metabolism, amino acids, bile acids and gut microbial metabolites. In particular, levels of pyroglutamic acid, glutamic acid, glycine and cysteine, were significantly higher in IBD children in the course of the study. This suggests that glutathione cannot be optimally synthesized and replenished. Whilst alterations of the enterohepatic circulation of bile acids in pediatric IBD patients is known, we show here that non-invasive urinary bile acid profiling can assess those altered hepatic and intestinal barrier dysfunctions. CONCLUSION The present study shows how non-invasive sampling of urine followed by targeted MS-based metabonomic analysis can elucidate and monitor the metabolic status of children with different GI health/disease status. PMID:28611517

  6. Longitudinal Urinary Protein Variability in Participants of the Space Flight Simulation Program.

    PubMed

    Khristenko, Nina A; Larina, Irina M; Domon, Bruno

    2016-01-04

    Urine is a valuable material for the diagnosis of renal pathologies and to investigate the effects of their treatment. However, the variability in protein abundance in the context of normal homeostasis remains a major challenge in urinary proteomics. In this study, the analysis of urine samples collected from healthy individuals, rigorously selected to take part in the MARS-500 spaceflight simulation program, provided a unique opportunity to estimate normal concentration ranges for an extended set of urinary proteins. In order to systematically identify and reliably quantify peptides/proteins across a large sample cohort, a targeted mass spectrometry method was developed. The performance of parallel reaction monitoring (PRM) analyses was improved by implementing tight control of the monitoring windows during LC-MS/MS runs, using an on-the-fly correction routine. Matching the experimentally obtained MS/MS spectra with reference fragmentation patterns allowed dependable peptide identifications to be made. Following optimization and evaluation, the targeted method was applied to investigate protein abundance variability in 56 urine samples, collected from six volunteers participating in the MARS-500 program. The intrapersonal protein concentration ranges were determined for each individual and showed unexpectedly high abundance variation, with an average difference of 1 order of magnitude.

  7. Comparison of Cannabinoid Concentrations in Plasma, Oral Fluid and Urine in Occasional Cannabis Smokers After Smoking Cannabis Cigarette.

    PubMed

    Marsot, Amélie; Audebert, Christine; Attolini, Laurence; Lacarelle, Bruno; Micallef, Joelle; Blin, Olivier

    A randomized cross-over, double blind placebo controlled study of smoked cannabis was carried out on occasional cannabis smokers. The objective of this research was to describe the pharmacokinetic parameters of THC and its metabolites in plasma, oral fluid and urine, from samples obtained simultaneously to provide estimations of THC and metabolites concentrations after smoking a cannabis cigarette. Blood, oral fluid and urine samples were collected until up to 72 h after smoking the cannabis cigarette (4% of delta-9-tetrathydrocannabinol (THC)). THC, 11-OH-THC and THC-COOH were analyzed by gas-chromatography-mass spectrometry. Pharmacokinetic parameters were estimated from these data. Eighteen male healthy adults participated in the study. In total, 560 plasma, 288 oral fluid and 448 urine samples were quantified for cannabinoids. Plasma, oral fluid and urine pharmacokinetic parameters were calculated. A wide range of median THC Cmax (1.6-160.0 µg/L and 55.4-123120.0 µg/L in plasma and oral fluid, respectively), 11-OH-THC Cmax (0-11.1 µg/L in plasma) and THC-COOH Cmax (1.0-56.3 µg/L in plasma) was observed. When expressed as a percentage of the total available THC dose, and corrected for molar equivalents, mean percentage of total THC dose excreted was 1.9 +/-2.5 % with range of 0.2-7.5%. This high inter-individual variability was also observed on other calculated pharmacokinetic parameters. Prediction of plasma THC concentration from THC oral fluid concentration or from THC-COOH urinary concentrations is not feasible due to the large variations observed. The results from this study support the assumption that a positive oral fluid THC result or a positive urine fluid result are indicative of a recent cannabis exposure. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.

  8. Determining the amounts of urea and glucose in urine of patients with renal complications from diabetes mellitus and hypertension by near-infrared Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Bispo, Jeyse A. M.; Silveira, Landulfo; Vieira, Elzo E. d. S.; Fernandes, Adriana B.

    2013-02-01

    Diabetes mellitus and hypertension diseases are frequently found in the same patient, which if untreated predispose to atherosclerotic and kidney diseases. The objective of this study was to identify potential biomarkers in the urine of diabetic and hypertensive patients through dispersive near-infrared Raman spectroscopy. Urine samples were collected from patients with diabetes and hypertension but no complications (LG), high degree of complications (HG), and control ones: one fraction was submitted to biochemical tests and another one was stored frozen (-20°C) until spectral analysis. Samples were warmed up and placed in an aluminum sample holder for Raman spectra collection using a dispersive spectrometer (830 nm wavelength, 300 mW laser power and 20 s exposure time). Spectra were then submitted to Principal Components Analysis. The PCA loading vectors 1 and 3 revealed spectral features of urea/creatinine and glucose, respectively; the PCA scores showed that patients with diabetes/hypertension (LG and HG) had higher amount of glucose in the urine compared to the normal group (p < 0.05), which can bring serious consequences to patients. Also, the PCA scores showed that the amount of urea decreased in the groups with diabetes/hypertension (p < 0.05), which generates the same concern as it is a marker that has a strong importance in the metabolic changes induced by such diseases. These results, applied to the analysis of urine of patients with diabetes/hypertension, can lead to early diagnostic information of complications and a possible disease prognosis in the patients where no complications from diabetes and hypertension were found.

  9. Simultaneous LC-MS/MS determination of JWH-210, RCS-4, ∆(9)-tetrahydrocannabinol, and their main metabolites in pig and human serum, whole blood, and urine for comparing pharmacokinetic data.

    PubMed

    Schaefer, Nadine; Kettner, Mattias; Laschke, Matthias W; Schlote, Julia; Peters, Benjamin; Bregel, Dietmar; Menger, Michael D; Maurer, Hans H; Ewald, Andreas H; Schmidt, Peter H

    2015-05-01

    A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 μg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.

  10. Hippuric Acid Levels in Paint Workers at Steel Furniture Manufacturers in Thailand

    PubMed Central

    Decharat, Somsiri

    2014-01-01

    Background The aims of this study were to determine hippuric acid levels in urine samples, airborne toluene levels, acute and chronic neurological symptoms, and to describe any correlation between urinary hippuric acid and airborne toluene. Methods The hippuric acid concentration in the urine of 87 paint workers exposed to toluene at work (exposed group), and 87 nonexposed people (control group) was studied. Study participants were selected from similar factories in the same region. Urine samples were collected at the end of a shift and analyzed for hippuric acid by high performance liquid chromatography. Air samples for the estimation of toluene exposure were collected with diffusive personal samplers and the toluene quantified using gas–liquid chromatography. The two groups were also interviewed and observed about their work practices and health. Results The median of the 87 airborne toluene levels was 55 ppm (range, 12–198 ppm). The median urinary hippuric acid level was 800 mg/g creatinine (range, 90–2547 mg/g creatinine). A statistically significant positive correlation was found between airborne toluene exposure and urine hippuric acid levels (r = 0.548, p < 0.01). Workers with acute symptoms had significantly higher hippuric acid levels than those who did not (p < 0.05). It was concluded that there was a significant correlation between toluene exposure, hippuric acid levels, and health (p < 0.001). Conclusion There appears to be a significant correlation between workers exposure to toluene at work, their urine hippuric acid levels, and resulting symptoms of poor health. Improvements in working conditions and occupational health education are required at these workplaces. There was good correlation between urinary hippuric acid and airborne toluene levels. PMID:25516817

  11. Identifying occupational and nonoccupational exposure to mercury in dental personnel.

    PubMed

    Shirkhanloo, Hamid; Fallah Mehrjerdi, Mohammad Ali; Hassani, Hamid

    2017-03-04

    The objective of this study was to investigate the occupational and nonoccupational exposure to mercury (Hg) vapor in dental personnel by examining the relationships between blood mercury, urine mercury, and their ratio with air mercury. The method was performed on 50 occupational exposed and 50 unexposed controls (25 men and 25 women). The mercury concentrations in air and human biological samples were determined based on the National Institute for Occupational Safety and Health (NIOSH) method and standard method (SM) by a new mode of liquid-phase microextraction, respectively. The mean mercury concentrations in urine (μg Hg 0 /g creatinine) and blood were significantly higher than control group, respectively (19.41 ± 5.18 vs 2.15 ± 0.07 μg/g and 16.40 ± 4.97 vs 2.50 ± 0.02 μg/L) (p <.001). The relationships between mercury concentration in blood/urine ratio (r = .380) with dental office air are new indicators for assessing occupational exposure in dental personnel.

  12. Recombined sequences between the non-coding control regions of JC and BK viruses found in the urine of a renal transplantation patient.

    PubMed

    Liaw, Yu-Ching; Chen, Cheng-Hsu; Shu, Kuo-Hsiung; Fang, Chiung-Yao; Ou, Wei-Chih; Chen, Pei-Lain; Shen, Cheng-Huang; Lin, Mien-Chun; Chang, Deching; Wang, Meilin

    2012-12-01

    Kidney cells are the common host for JC virus (JCV) and BK virus (BKV). Reactivation of JCV and/or BKV in patients after organ transplantation, such as renal transplantation, may cause hemorrhagic cystitis and polyomavirus-associated nephropathy. Furthermore, JCV and BKV may be shed in the urine after reactivation in the kidney. Rearranged as well as archetypal non-coding control regions (NCCRs) of JCV and BKV have been frequently identified in human samples. In this study, three JC/BK recombined NCCR sequences were identified in the urine of a patient who had undergone renal transplantation. They were designated as JC-BK hybrids 1, 2, and 3. The three JC/BK recombinant NCCRs contain up-stream JCV as well as down-stream BKV sequences. Deletions of both JCV and BKV sequences were found in these recombined NCCRs. Recombination of DNA sequences between JCV and BKV may occur during co-infection due to the relatively high homology of the two viral genomes.

  13. Evaluation of immunologic effect of Enniatin A and quantitative determination in feces, urine and serum on treated Wistar rats.

    PubMed

    Juan, Cristina; Manyes, Lara; Font, Guillermina; Juan-García, Ana

    2014-09-01

    Study of dietary supplementation with ENN A mycotoxin during 28 days of exposure time on Wistar rats to determinate its levels in serum, urine and feces and, to evaluate the immunologic effect in peripheral blood lymphocytes (PBL) is presented. The first method for ENN A extraction, determination and detection by LC-MS/MS in serum, urine and feces samples is reported. ENN A food dose administrated was detected in serum samples and influenced lymphocyte phenotyping. Levels in serum were founded from the second week of the experiment; reaching values of 4.76 μg/ml on the fourth week, which corresponds to 3.24 μg/ml in blood. PBL as T helper (CD4(+)) were presented in greater percentages compared to control (p ≤ 0.001), while T cytotoxic (CD8(+)) decreased significantly compared to control (p ≤ 0.001). ENN A treatment significantly increased CD4(+)/CD3(+) and CD4(+)/CD8(+) ratios but significantly decreased CD8(+)/CD3(+) ratio. CD4(+)/CD8(+) ratio was 2.94:1, indicating that PBL surface antigen expression and immune status in Wistar rats treated were impaired by the ENN A mycotoxin. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Metabolomic Fingerprinting in Various Body Fluids of a Diet-Controlled Clinical Smoking Cessation Study Using a Validated GC-TOF-MS Metabolomics Platform.

    PubMed

    Goettel, Michael; Niessner, Reinhard; Mueller, Daniel; Scherer, Max; Scherer, Gerhard; Pluym, Nikola

    2017-10-06

    Untargeted GC-TOF-MS analysis proved to be a suitable analytical platform to determine alterations in the metabolic profile. Several metabolic pathways were found to be altered in a first clinical study comparing smokers against nonsmokers. Subsequently, we conducted a clinical diet-controlled study to investigate alterations in the metabolic profile during the course of 3 months of smoking cessation. Sixty male subjects were included in the study, and plasma, saliva, and urine samples were collected during four 24 h stationary visits: at baseline, while still smoking, after 1 week, after 1 month, and after 3 months of cessation. Additionally, subjects were monitored for their compliance by measurements of CO in exhaled breath and salivary cotinine throughout the study. GC-TOF-MS fingerprinting was applied to plasma, saliva, and urine samples derived from 39 compliant subjects. In total, 52 metabolites were found to be significantly altered including 26 in plasma, 20 in saliva, and 12 in urine, respectively. In agreement with a previous study comparing smokers and nonsmokers, the fatty acid and amino acid metabolism showed significant alterations upon 3 months of smoking cessation. Thus these results may indicate a partial recovery of metabolic pathway perturbations, even after a relatively short period of smoking cessation.

  15. Multi residue screening of intact testosterone esters and boldenone undecylenate in bovine hair using liquid chromatography electrospray tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Lasaroms, Johan J P; Mulder, Patrick P J; Van Hende, Johan; van Rhijn, J Hans A; Groot, Maria J

    2006-01-02

    The abuse of esters of natural androgenic steroids in cattle fattening and sports is hard to control via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. In veterinary control strange findings of 17beta-testosterone and 17alpha-testosterone in urine are often ignored because of the lack of statistically sound reference data of naturally occurring levels. An interesting alternative for inconclusive urine analyses in veterinary control can be provided by the analysis of the administered steroids themselves, i.e. the analysis of intact steroid esters in hair. Unfortunately, the analysis of intact steroid esters is complicated not only by the vulnerability of the esters which precludes alkaline hydrolysis of the hair, but also by the wide polarity range of short and long-chain esters yielding very poor recoveries for either the one or the other. In this study, a multi-steroid esters LC/MS/MS screening method is presented for trace analysis of the synthetic intact esters of 17beta-testosterone and the undecylenate ester of 17beta-boldenone in bovine hair. The method, requiring only 200 mg of pulverised hair, features a mild digestion procedure using tris(2-carboxyethyl)phosphine hydrochloride (TCEP) and the use of four deuterium-labelled steroid esters as internal standards covering the wide polarity range of the analytes. In spiked hair samples for most of the analytes the limit of detection and the accuracy using isotope dilution were 2-5 ng/g and 97-105%, respectively. The applicability was demonstrated using hair samples from a controlled experiment in which six bovines were injected intramuscularly with two different doses of two commercial mixtures of testosterone esters, and with two different doses of boldenone undecylenate. Depending on the dose all administered testosterone- and boldenone esters were found to be incorporated in bovine hair following a single intramuscular injection, except testosterone propionate which dose might have been too low.

  16. Evaluating levels and health risk of heavy metals in exposed workers from surgical instrument manufacturing industries of Sialkot, Pakistan.

    PubMed

    Junaid, Muhammad; Hashmi, Muhammad Zaffar; Malik, Riffat Naseem

    2016-09-01

    The study aimed to monitor heavy metal (chromium, Cr; cadmium, Cd; nickel, Ni; copper, Cu; lead, Pb; iron, Fe; manganese, Mn; and zinc, Zn) footprints in biological matrices (urine, whole blood, saliva, and hair), as well as in indoor industrial dust samples, and their toxic effects on oxidative stress and health risks in exposed workers. Overall, blood, urine, and saliva samples exhibited significantly higher concentrations of toxic metals in exposed workers (Cr; blood 16.30 μg/L, urine 58.15 μg/L, saliva 5.28 μg/L) than the control samples (Cr; blood 5.48 μg/L, urine 4.47 μg/L, saliva 2.46 μg/L). Indoor industrial dust samples also reported to have elevated heavy metal concentrations, as an example, Cr quantified with concentration of 299 mg/kg of dust, i.e., more than twice the level of Cr in household dust (136 mg/kg). Superoxide dismutase (SOD) level presented significant positive correlation (p ≤ 0.01) with Cr, Zn, and Cd (Cr > Zn > Cd) which is an indication of heavy metal's associated raised oxidative stress in exposed workers. Elevated average daily intake (ADI) of heavy metals resulted in cumulative hazard quotient (HQ) range of 2.97-18.88 in workers of different surgical units; this is an alarming situation of health risk implications. Principal component analysis-multiple linear regression (PCA-MLR)-based pie charts represent that polishing and cutting sections exhibited highest metal inputs to the biological and environmental matrices than other sources. Heavy metal concentrations in biological matrices and dust samples showed a significant positive correlation between Cr in dust, urine, and saliva samples. Current study will help to generate comprehensive base line data of heavy metal status in biomatrices and dust from scientifically ignored industrial sector. Our findings can play vital role for health departments and industrial environmental management system (EMS) authorities in policy making and implementation.

  17. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    PubMed

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Real-Time Polymerase Chain Reaction for Detection of Schistosoma DNA in Small-Volume Urine Samples Reflects Focal Distribution of Urogenital Schistosomiasis in Primary School Girls in KwaZulu Natal, South Africa

    PubMed Central

    Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette

    2014-01-01

    Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560

  19. Development of Technologies for Early Detection and Stratification of Breast Cancer

    DTIC Science & Technology

    2014-10-01

    cancer. Similar screening has been done in urine samples with CYR61 and LCN2 (Figure 2a-b). The Moses lab provided breast cancer urine samples and two ...diseased samples, while CYR61 appears to have two different populations whereas diseased urine samples have lower levels of the protein present. More... system for eDAR so that each isolated cell can be deposited into a well of a 96-well plate for high-throughput downstream single-cell digital

  20. Quality control of test iodine in urine by spectrophotometry UV-Vis

    NASA Astrophysics Data System (ADS)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  1. Immunoreactive LH in long-term frozen human urine samples.

    PubMed

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.

    PubMed

    Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O

    1996-01-01

    This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.

  4. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less

  5. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    PubMed

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  6. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  7. Association between arsenic exposure from a coal-burning power plant and urinary arsenic concentrations in Prievidza District, Slovakia.

    PubMed

    Ranft, Ulrich; Miskovic, Peter; Pesch, Beate; Jakubis, Pavel; Fabianova, Elenora; Keegan, Tom; Hergemöller, Andre; Jakubis, Marian; Nieuwenhuijsen, Mark J

    2003-06-01

    To assess the arsenic exposure of a population living in the vicinity of a coal-burning power plant with high arsenic emission in the Prievidza District, Slovakia, 548 spot urine samples were speciated for inorganic As (Asinorg), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), and their sum (Assum). The urine samples were collected from the population of a case-control study on nonmelanoma skin cancer (NMSC). A total of 411 samples with complete As speciations and sufficient urine quality and without fish consumption were used for statistical analysis. Although current environmental As exposure and urinary As concentrations were low (median As in soil within 5 km distance to the power plant, 41 micro g/g; median urinary Assum, 5.8 microg/L), there was a significant but weak association between As in soil and urinary Assum(r = 0.21, p < 0.01). We performed a multivariate regression analysis to calculate adjusted regression coefficients for environmental As exposure and other determinants of urinary As. Persons living in the vicinity of the plant had 27% higher Assum values (p < 0.01), based on elevated concentrations of the methylated species. A 32% increase of MMA occurred among subjects who consumed homegrown food (p < 0.001). NMSC cases had significantly higher levels of Assum, DMA, and Asinorg. The methylation index Asinorg/(MMA + DMA) was about 20% lower among cases (p < 0.05) and in men (p < 0.05) compared with controls and females, respectively.

  8. Association between arsenic exposure from a coal-burning power plant and urinary arsenic concentrations in Prievidza District, Slovakia.

    PubMed Central

    Ranft, Ulrich; Miskovic, Peter; Pesch, Beate; Jakubis, Pavel; Fabianova, Elenora; Keegan, Tom; Hergemöller, Andre; Jakubis, Marian; Nieuwenhuijsen, Mark J

    2003-01-01

    To assess the arsenic exposure of a population living in the vicinity of a coal-burning power plant with high arsenic emission in the Prievidza District, Slovakia, 548 spot urine samples were speciated for inorganic As (Asinorg), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), and their sum (Assum). The urine samples were collected from the population of a case-control study on nonmelanoma skin cancer (NMSC). A total of 411 samples with complete As speciations and sufficient urine quality and without fish consumption were used for statistical analysis. Although current environmental As exposure and urinary As concentrations were low (median As in soil within 5 km distance to the power plant, 41 micro g/g; median urinary Assum, 5.8 microg/L), there was a significant but weak association between As in soil and urinary Assum(r = 0.21, p < 0.01). We performed a multivariate regression analysis to calculate adjusted regression coefficients for environmental As exposure and other determinants of urinary As. Persons living in the vicinity of the plant had 27% higher Assum values (p < 0.01), based on elevated concentrations of the methylated species. A 32% increase of MMA occurred among subjects who consumed homegrown food (p < 0.001). NMSC cases had significantly higher levels of Assum, DMA, and Asinorg. The methylation index Asinorg/(MMA + DMA) was about 20% lower among cases (p < 0.05) and in men (p < 0.05) compared with controls and females, respectively. PMID:12782488

  9. Determination of urine oxalate level in rats with renal calcium oxalate calculus by high-performance liquid chromatography.

    PubMed

    Cao, Qiu-shi; Ba, Yuan-ming; Luo, Jun-hua; Dai, Qi

    2015-02-01

    To establish a method of high-performance liquid chromatography (HPLC) for determining the urine oxalate levle in rats with renal calcium oxalate calculus. Totally 24 SPF Wistar healthy male rats were randomly divided into control group(n=12)and ethylene glycol (EG) group (n=12). Rats in EG group were administered intragastrically with 2% ammonium chloride (AC)2 ml/rat per day+1% ethylene glycol (EG), along with free access to drinking water.The control group was fed with deionized water, along with the intragastric administration of normal saline (1 ml per day). Twenty-eight days after modelling, the 24-hour urine samples were collected, and the urine oxalic acid levels were determined using HPLC and the results were compared with those of catalytic spectrophotometry using oxidation of methyl. During the HPLC, the samples were separated on Aglient 5TC-C18 (250×4.6 mm,5 Μm), eluted with mixture of methanol (0.1 mol/L) and ammonium acetate (15:85) at 1.2 ml/min, and detected at 314 nm, with the column temperature being 20 ℃. The standard curves of high and low concentrations of oxalic acid were y=5909.1x+378730, R² =0.9984 and y=7810.5x-16635, R² =0.9967,respectively. The lowest detectable concentration in this method was 5 Μg/ml. The linear high concentration range of oxalate stood at 62.50-2000.00 Μg/ml, and the linear low concentration range of oxalate stood at 6.25-100.00 Μg/ml. Its average recovery was 95.1%, and its within-day and day-to-day precisions were 3.4%-10.8% and 3.8%-9.4%. Both HPLC and catalytic spectrophotometry showed significantly higher urinary oxalic acid concentration and 24 h urine oxalate level in EG group compared with the control group [urinary oxalic acid concentration: (736.35 ± 254.52) Μg/ml vs.(51.56 ± 36.34) Μg/ml,(687.35 ± 234.53) Μg/ml vs.(50.24 ± 42.34) Μg/ml;24 h urine oxalate level: (11.23 ± 4.12)mg vs.(0.87 ± 0.45)mg,(9.89 ± 3.55)mg vs. (0.77 ± 0.65)mg; all P<0.01]. No statistically significant difference was observed in the results of urinary oxalate concentration and 24 h urine oxalate level between HPLC and potassium chromate oxidation of methyl red spectrophotometry (all P>0.05). HPLC is a simple, rapid, and precise method in detecting urine oxalate level in rats with renal calcium oxalate calculus, with high recovery rate.

  10. Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.

    PubMed

    Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R

    1994-12-01

    LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.

  11. Combined quantification of paclitaxel, docetaxel and ritonavir in human feces and urine using LC-MS/MS.

    PubMed

    Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-02-01

    A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.

    PubMed

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.

  13. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine

    PubMed Central

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable. PMID:26208298

  14. Improved bacterial identification directly from urine samples with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato

    2018-03-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.

  15. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  16. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

  17. Surveying Mercury Levels in Hair, Blood and Urine of under 7-Year Old Children from a Coastal City in China

    PubMed Central

    Chen, Guixia; Chen, Xiaoxin; Yan, Chonghuai; Wu, Xingdong; Zeng, Guozhang

    2014-01-01

    Aim: The average mercury load in children under 7-years old was determined in a populated but not overly industrial coastal area in China. Methods: 395 blood samples, 1072 urine samples, and 581 hair samples were collected from 1076 children, aged 0 to 6 years, from eight representative communities of Xiamen, China. Mercury levels in the samples were surveyed. Results: The 95% upper limits of mercury in blood, urine, and hair for the children were 2.30, 1.50 and 2100.00 μg/kg, respectively. Levels tended to increase with age. Correlation analyses showed that mercury levels in blood and urine correlated with those in hair (n = 132), r = 0.49, p < 0.0001 and r = 0.20, p = 0.0008; however, blood mercury levels did not correlate with urine levels (n = 284), r = 0.07, p = 0.35. Conclusions: Surveying the average mercury load in children 0 to 6 years, and the 95% upper limit value of mercury in their blood, urine, and hair should help guide risk assessment and health management for children. PMID:25419876

  18. Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients

    PubMed Central

    Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon

    2013-01-01

    In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973

  19. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  20. Occupational exposure of electrical utility linemen to pentachlorophenol.

    PubMed

    Thind, K S; Karmali, S; House, R A

    1991-12-01

    Occupational exposure to pentachlorophenol (PCP) for a crew of electrical utility linemen was monitored over a 6-month period by using total PCP in urine per gram of creatinine as a biological monitoring parameter. Urine samples were collected from three groups: A, B, and control, at a 4-week frequency during 1989. Group A was required to use new gloves after each 4-week work period; Group B changed gloves on a need basis as per normal operating procedure. The control group consisted of members of the administrative office staff who were not occupationally exposed. The used gloves returned by Group A were monitored for contamination. On the basis of analysis of the collected data the following conclusions were noted. (1) The linemen experienced a seasonal exposure pattern with exposures peaking in July and August. This seasonal effect was also observed with glove contamination data. (2) The glove contamination levels were significantly associated with urine PCP concentrations when both these variables were expressed as geometric means for the individuals in Group A. Inclusion of work experience as an additional variable enhances this association. Less experienced linemen tended to perform more activities with higher current exposure and had higher urine and glove PCP measurements and higher correlations between these variables than more experienced linemen. (3) Over the study period, the difference in long-term exposures of Group A and Group B linemen was not statistically significant. (4) The long-term individual exposures, calculated as the geometric mean of each individual's sequential sample readings, were all below the biological monitoring guideline value of 1000 micrograms PCP/g creatinine.

  1. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

  2. Reproducibility of urinary biomarkers in multiple 24-h urine samples.

    PubMed

    Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C

    2017-01-01

    Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.

  3. Reproducibility of urinary biomarkers in multiple 24-h urine samples123

    PubMed Central

    Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C

    2017-01-01

    Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663

  4. [The BK virus load in urine in association with the development of hemorrhagic cystitis after hematopoietic stem cell transplantation].

    PubMed

    Xie, Ying; Han, Yue; Wu, De-pei; Sun, Ai-ning; Cen, Jian-nong; Yao, Li; Ruan, Chang-geng

    2009-08-01

    To analyze the relationship between BK viruria and the late onset hemorrhagic cystitis (LOHC) after hematopoietic stem cell transplantation (HSCT), and investigate the role of BK virus load in the development of LOHC. From August 2006 to April 2008, urine samples were collected weekly from 113 patients undergoing HSCT. Virus DNA were extracted from the urine samples and amplified by qualitative PCR. Real-time quantitative PCR was used to quantify BKV DNA in the urine samples of all BK viruria patients. LOHC occurred in 22 patients (19.5%), including grade 1 in 7, grade 2 in 11, grade 3 in 3, and grade 4 in one. The median onset time was 44 (13 - 114) days after transplantation. Twenty-one of which (95.5%) were BK virus positive, being significantly higher than that in non-LOHC patients (31.9%) (P = 0.000). No BK virus was detected in the healthy control group at the same time. Quantitative PCR detection showed that the mean BK virus DNA copies in LOHC patients at a week before occurring HC was higher than that at the first positive samples (10(5) copies/microl versus 10(4) copies/microl, P = 0.025), and it was no significant change at the onset and a week after HC. Meanwhile, there was no statistical difference in the mean level of BK virus DNA copies among the LOHC patients with different grades. The mean level of BK virus DNA copies in non-HC patients was 10(3) to 10(4) copies/microl, being lower than that in LOHC patients. BK viruria is an important pathogenic cause of the LOHC after HSCT. The occurrence of BKV viruria in HSCT patients, together with the increasing of BK virus DNA copies in urine, over the level of 10(5) copies/microl may indicate a possible development of LOHC.

  5. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Urinary 1-Hydroxypyrene as a Biomarker to Carcinogenic Polycyclic Aromatic Hydrocarbon Exposure

    PubMed Central

    Ifegwu, Clinton; Osunjaye, Kayode; Fashogbon, Folasade; Oke, Kolawole; Adeniyi, Afolabi; Anyakora, Chimezie

    2012-01-01

    In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 ºC and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects. PMID:24179391

  7. Urinary 1-hydroxypyrene as a biomarker to carcinogenic polycyclic aromatic hydrocarbon exposure.

    PubMed

    Ifegwu, Clinton; Osunjaye, Kayode; Fashogbon, Folasade; Oke, Kolawole; Adeniyi, Afolabi; Anyakora, Chimezie

    2012-01-01

    In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 ºC and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects.

  8. 21 CFR 58.195 - Retention of records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... specimens (except those specimens obtained from mutagenicity tests and wet specimens of blood, urine, feces, and biological fluids), samples of test or control articles, and specially prepared material, which are relatively fragile and differ markedly in stability and quality during storage, shall be retained...

  9. Calcium Stone Growth in Urine from Cystic Fibrosis Patients and Healthy Controls

    NASA Astrophysics Data System (ADS)

    McSorley, Anita; Jones, Andrew M.; Webb, A. Kevin; Rao, P. Nagaraj; Kavanagh, John P.

    2007-04-01

    Cystic fibrosis patients have an increased risk of renal stone disease. There is some evidence that this may be related to a different excretory pattern of stone risk factors, but an alternative hypothesis, that the urine of cystic fibrosis patients is deficient in urinary inhibitors of crystallization and stone formation has not been tested. Here we have grown calcium stones, in vitro, in the presence of urine from healthy controls and compared this with growth in the presence of urine from cystic fibrosis patients. A stone farm was used to grow twelve calcium stones simultaneously, firstly in artificial urine for about 200 hours and then in 90% whole human urine for another 500 hours. Six of the stones received urine from healthy controls and six received urine from adult cystic fibrosis patients. There were no significant differences in stone mass at any of the key time points or in the overall growth pattern (p>0.05) between stones destined for, or treated with, urine from CF patients and the controls. Human urine greatly inhibited stone growth in vitro but there was no difference in the growth rate in urine from healthy controls and CF patients. This refutes the hypothesis that a tendency for a higher prevalence of urinary stones in CF patients is related to a deficiency in inhibitory activity.

  10. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  11. Urinary incontinence

    MedlinePlus

    Loss of bladder control; Uncontrollable urination; Urination - uncontrollable; Incontinence - urinary ... have diabetes, keep your blood sugar under good control. For urine leaks, wear absorbent pads or undergarments. ...

  12. Analytical precision of the Urolizer for the determination of the BONN-Risk-Index (BRI) for calcium oxalate urolithiasis and evaluation of the influence of 24-h urine storage at moderate temperatures on BRI.

    PubMed

    Berg, Wolfgang; Bechler, Robin; Laube, Norbert

    2009-01-01

    Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.

  13. Mining the human urine proteome for monitoring renal transplant injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less

  14. Comparison of Uriswab to alternative methods for urine culture collection and transport: confirmation of standard culture methodology for investigation of urinary tract infections.

    PubMed

    Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan

    2016-08-01

    The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Distribution of caffeine levels in urine in different sports in relation to doping control before and after the removal of caffeine from the WADA doping list.

    PubMed

    Van Thuyne, W; Delbeke, F T

    2006-09-01

    Caffeine concentrations were measured in the urine of 4633 athletes tested for doping control in the Ghent Doping Control Laboratory in 2004. Determination of these concentrations was done using an alkaline extraction with a mixture of dichloromethane and methanol (9 : 1; v/v) followed by high performance liquid chromatography and ultraviolet detection (HPLC-UV). The method was validated according to ISO 17 025 standards (International Organisation for Standardisation). Quantification was done by using a linear calibration curve in the range from 0 to 20 microg/ml. The limit of quantification (LOQ) was 0.10 microg/ml. Because the results were not normally distributed, transformation of the data was done to evaluate the difference in detected concentrations in several sports. This resulted in an overall average concentration of 1.12 +/- 2.68 microg/ml. Comparison of the most frequently tested sports in 2004 demonstrated that caffeine concentrations in samples originating from power lifters are significantly higher in comparison to urines taken in other sports. Also, a significant difference between caffeine concentrations found in cycling and concentrations found in other sports, including athletics and some ball sports, was observed. A comparison was made between results obtained in 2004 and results obtained before the removal of caffeine from the WADA (World Anti-Doping Agency) doping list indicating that average caffeine concentrations decreased after the withdrawal of caffeine from the list of prohibited substances. The overall percentage of positive samples between the two periods remained the same although the percentage of positive samples noticed in cycling increased after the removal of caffeine from the doping list.

  16. Voltammetric analysis of ceftazidime after preconcentration at various mercury and carbon electrodes: application to sub-ppb level determination in urine samples.

    PubMed

    El-Maali, N A

    2000-04-28

    The electrochemical behavior of ceftazidime (CFZ) at four different kinds of electrodes viz. static mercury drop electrode (SMDE), controlled growth mercury electrode (CGME), glassy carbon electrode (GCE) and carbon paste electrode (CPE) has been presented. Optimal operational parameters have been selected for the drug preconcentration and determination in aqueous medium. Down to 2x10(-10) M CFZ is achieved as detection limit at the CGME. Modification of the CPE with polyvinyl alcohol (PVA) enhances both the sensitivity and selectivity for the drug accumulation and, therefore, its determination at very low levels. Application of the proposed method for CFZ analysis in spiked urine samples or those taken after metabolism has been easily assessed. Down to 1x10(-9) M CFZ (0.695 ng ml(-1)) could be easily achieved in such samples.

  17. A therapeutic workplace for the long-term treatment of drug addiction and unemployment: eight-year outcomes of a social business intervention.

    PubMed

    Aklin, Will M; Wong, Conrad J; Hampton, Jacqueline; Svikis, Dace S; Stitzer, Maxine L; Bigelow, George E; Silverman, Kenneth

    2014-01-01

    This study evaluated the long-term effects of a therapeutic workplace social business on drug abstinence and employment. Pregnant and postpartum women (N = 40) enrolled in methadone treatment were randomly assigned to a therapeutic workplace or usual care control group. Therapeutic workplace participants could work weekdays in training and then as employees of a social business, but were required to provide drug-free urine samples to work and maintain maximum pay. Three-year outcomes were reported previously. This paper reports 4- to 8-year outcomes. During year 4 when the business was open, therapeutic workplace participants provided significantly more cocaine- and opiate-negative urine samples than controls; reported more days employed, higher employment income, and less money spent on drugs. During the 3 years after the business closed, therapeutic workplace participants only reported higher income than controls. A therapeutic workplace social business can maintain long-term abstinence and employment, but additional intervention may be required to sustain effects. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Impact of Prolonged Fasting on the Risk of Calcium Phosphate Precipitation in the Urine: Calcium Phosphate Lithogenesis during Prolonged Fasting in a Healthy Cohort.

    PubMed

    Shafiee, Mohammad A; Aarabi, Mehdi; Shaker, Pouyan; Ghafarian, Amir M; Chamanian, Pouyan; Halperin, Mitchell L

    2018-03-02

    Intermittent fasting and curtailing water intake for extended periods were likely common in Paleolithic times. Today it occurs for religious and dietary reasons. This restriction in intake should cause a decrease in the urine flow rate while raising the concentration of certain substances in urine to the point of precipitation. In this study we measured the risk of CaHPO 4 precipitation following 18 hours of food and water deprivation. Urine samples were periodically collected from 15 healthy subjects who fasted and abstained from drinking any liquid for 18 hours. The urine constituents Ca 2+ , HPO 4 2- and pH involved in CaHPO 4 formation were measured at various times throughout the fasting day. A comparison was made with control data, which consisted of diurnal urine collections taken throughout a separate nonfasting day prior to the fasting day. The mean ± SEM urine flow rate decreased significantly from 0.93 ± 0.1 ml per minute in the control group to 0.37 ± 0.05 ml per minute in the fasting group (p <0.05). Mean Na + and Ca 2+ excretion rates decreased significantly from 127 ± 12 to 54 ± 13 μmol per minute and from 3.2 ± 0.4 to 0.80 ± 0.21, respectively. Mean urinary Na + and Ca 2+ concentrations also decreased from 161 ± 11.6 to 122 ± 16.0 mmol/l and from 3.7 ± 0.5 to 2.0 ± 0.55, respectively. Urinary pH and the concentration of phosphate, citrate and magnesium were not significantly affected. Although the steady decrease in the urine flow rate was statistically significant during 18 hours of food and water deprivation, there was no evidence that the calculated risk of CaHPO 4 precipitation in the healthy subjects had increased. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Cannabinoids assessment in plasma and urine by high performance liquid chromatography-tandem mass spectrometry after molecularly imprinted polymer microsolid-phase extraction.

    PubMed

    Sánchez-González, Juan; Salgueiro-Fernández, Rocío; Cabarcos, Pamela; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2017-02-01

    A molecularly imprinted polymer (MIP) selective for cannabinoids [Δ 9 -tetrahydrocannabinol (Δ9-THC), 11-nor-9-carboxy-Δ 9 -tetrahydrocannabinol (Δ9-THC-COOH), and 11-hydroxy-Δ 9 -tetrahydrocannabinol (Δ9-THC-OH)] has been synthesized, fully characterized, and applied to the assessment of plasma and urine analysis of marijuana abuse by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Δ9-THC-COOH was used as a template molecule, whereas ethylene glycol dimethacrylate (EGDMA) was used as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The prepared MIP was found to be highly selective for cannabinoids typically found in blood and urine, and also for cannabinol (CBN) and cannabidiol (CBD). MIP beads (50 mg) were loaded inside a cone-shaped device made of a polypropylene (PP) membrane for microsolid-phase extraction (μ-SPE) in batch mode. Optimum retention of analytes (0.1 to 1.0 mL of plasma/urine) was achieved by fixing plasma/urine pH at 6.5 and assisting the procedure by mechanical shaking (150 rpm, 40 °C, 12 min). Optimum elution conditions implied 2 mL of a 90:10 methanol/acetic acid and ultrasound extraction (35 kHz, 325 W) for 6 min. Good precision was assessed by intra-day and inter-day assays. In addition, the method was found to be accurate after intra-day and inter-day analytical recovery assays and after analyzing control serum and urine control samples. The limits of quantification were in the range of 0.36-0.49 ng L -1 (plasma analysis) and 0.47-0.57 ng L -1 (urine analysis). These values are low enough for confirmative conclusions regarding marijuana abuse through blood and urine analysis. Graphical Abstract ᅟ.

  20. Excretion profile of boldenone in urine of veal calves fed two different milk replacers.

    PubMed

    Draisci, R; Merlanti, R; Ferretti, G; Fantozzi, L; Ferranti, C; Capolongo, F; Segato, S; Montesissa, C

    2007-03-14

    The residue profiles of 17alpha-/17beta-boldenone conjugated (17alpha/beta-Bol) and ADD were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in urine of male veal calves fed two commercial milk replacers, with different content of cholesterol and phytosterols. The urine samples were collected within 4 h after feeding and further from all the animals. Detectable amounts of 17alpha-Bol conjugated were measured in urine collected from all calves, but the concentrations of 17alpha-Bol were higher in urine from calves receiving the milk replacer with the greater amount of phytosterols. During the whole experiment, 17beta-Bol and ADD were never detected in urine samples collected.

  1. Establishment of a Method for Measuring Antioxidant Capacity in Urine, Based on Oxidation Reduction Potential and Redox Couple I2/KI

    PubMed Central

    Cao, Tinghui; He, Min; Bai, Tianyu

    2016-01-01

    Objectives. To establish a new method for determination of antioxidant capacity of human urine based on the redox couple I2/KI and to evaluate the redox status of healthy and diseased individuals. Methods. The method was based on the linear relationship between oxidation reduction potential (ORP) and logarithm of concentration ratio of I2/KI. ORP of a solution with a known concentration ratio of I2/KI will change when reacted with urine. To determine the accuracy of the method, both vitamin C and urine were reacted separately with I2/KI solution. The new method was compared with the traditional method of iodine titration and then used to measure the antioxidant capacity of urine samples from 30 diabetic patients and 30 healthy subjects. Results. A linear relationship was found between logarithm of concentration ratio of I2/KI and ORP (R 2 = 0.998). Both vitamin C and urine concentration showed a linear relationship with ORP (R 2 = 0.994 and 0.986, resp.). The precision of the method was in the acceptable range and results of two methods had a linear correlation (R 2 = 0.987). Differences in ORP values between diabetic group and control group were statistically significant (P < 0.05). Conclusions. A new method for measuring the antioxidant capacity of clinical urine has been established. PMID:28115919

  2. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

    PubMed

    Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee

    2016-09-01

    The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.

  3. Determination of growth hormone releasing peptides metabolites in human urine after nasal administration of GHRP-1, GHRP-2, GHRP-6, Hexarelin, and Ipamorelin.

    PubMed

    Semenistaya, Ekaterina; Zvereva, Irina; Thomas, Andreas; Thevis, Mario; Krotov, Grigory; Rodchenkov, Grigory

    2015-10-01

    Growth hormone releasing peptides (GHRPs) stimulate secretion of endogenous growth hormone and are listed on the World Anti-Doping Agency (WADA) Prohibited List. To develop an effective method for GHRPs anti-doping control we have investigated metabolites of GHRP-1, GHRP-2, GHRP-6, Hexarelin, and Ipamorelin in urine after nasal administration. Each compound was administrated to one volunteer. Samples were collected for 2 days after administration, processed by solid-phase extraction on weak cation exchange cartridges and analyzed by means of nano-liquid chromatography - high resolution mass spectrometry. Six metabolites of GHRP-1 were identified. GHRP-1 in the parent form was not detected. GHRP-1 (2-4) free acid was detected in urine up to 27 h. GHRP-2, GHRP-2 free acid and GHRP-2 (1-3) free acid were detected in urine up to 47 h after administration. GHRP-6 was mostly excreted unchanged and detected in urine 23 h after administration, its metabolites were detectable for 12 h only. Hexarelin and Ipamorelin metabolized intensively and were excreted as a set of parent compounds with metabolites. Hexarelin (1-3) free acid and Ipamorelin (1-4) free acid were detected in urine samples after complete withdrawal of parent substances. GHRPs and their most prominent metabolites were included into routine ultra-pressure liquid chromatography-tandem mass spectrometry procedure. The method was fully validated, calibration curves of targeted analytes were obtained and excretion curves of GHRPs and their metabolites were plotted. Our results confirm that the detection window after GHRPs administration depends on individual metabolism, drug preparation form and the way of administration. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Sample handling for mass spectrometric proteomic investigations of human urine.

    PubMed

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  6. Performance of Copan WASP for Routine Urine Microbiology

    PubMed Central

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  7. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    PubMed

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  8. Evaluation of equine urine reactivity towards phase II metabolites of 17-hydroxy steroids by liquid chromatography/tandem mass spectrometry.

    PubMed

    Fidani, M; Gamberini, M C; Pasello, E; Palazzoli, F; De Iuliis, P; Montana, M; Arioli, F

    2009-01-01

    Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17beta- and 17alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. (c) 2008 John Wiley & Sons, Ltd.

  9. Simultaneous and confirmative detection of multi-residues of β₂-agonists and β-blockers in urine using LC-MS/MS/MS coupled with β-receptor molecular imprinted polymer SPE clean-up.

    PubMed

    Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N

    2013-01-01

    A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.

  10. Impact of urine preservation methods and duration of storage on measured levels of environmental contaminants.

    PubMed

    Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S

    2006-01-01

    Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.

  11. Quantitative analysis of zopiclone, N-desmethylzopiclone, zopiclone N-oxide and 2-amino-5-chloropyridine in urine using LC-MS-MS.

    PubMed

    Nilsson, Gunnel H; Kugelberg, Fredrik C; Ahlner, Johan; Kronstrand, Robert

    2014-01-01

    A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. 40 CFR 160.195 - Retention of records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., terminated, or discontinued. (c) Wet specimens, samples of test, control, or reference substances, and... storage, shall be retained only as long as the quality of the preparation affords evaluation. Specimens obtained from mutagenicity tests, specimens of soil, water, and plants, and wet specimens of blood, urine...

  13. Feasibility of collecting 24-h urine to monitor sodium intake in the National Health and Nutrition Examination Survey123

    PubMed Central

    Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A

    2016-01-01

    Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136

  14. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    PubMed

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  15. Enhanced amperometric detection of metronidazole in drug formulations and urine samples based on chitosan protected tetrasulfonated copper phthalocyanine thin-film modified glassy carbon electrode.

    PubMed

    Meenakshi, S; Pandian, K; Jayakumari, L S; Inbasekaran, S

    2016-02-01

    An enhanced electrocatalytic reduction of metronidazole antibiotic drug molecule using chitosan protected tetrasulfonated copper phthalocyanine (Chit/CuTsPc) thin-film modified glassy carbon electrode (GCE) has been developed. An irreversible reduction occurs at -0.47V (vs. Ag/AgCl) using Chit/CuTsPc modified GCE. A maximum peak current value is obtained at pH1 and the electrochemical reduction reaction is a diffusion controlled one. The detection limit is found to be 0.41nM from differential pulse voltammetry (DPV) method. This present investigation method is adopted for electrochemical detection of metronidazole in drug formulation and urine samples by using DPV method. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Artificial Urine for Teaching Urinalysis Concepts and Diagnosis of Urinary Tract Infection in the Medical Microbiology Laboratory.

    PubMed

    Khan, Latifa B; Read, Hannah M; Ritchie, Stephen R; Proft, Thomas

    2017-01-01

    Dipstick urinalysis is an informative, quick, cost-effective and non-invasive diagnostic tool that is useful in clinical practice for the diagnosis of urinary tract infections (UTIs), kidney diseases, and diabetes. We used dipstick urinalysis as a hands-on microbiology laboratory exercise to reinforce student learning about UTIs with a particular focus on cystitis, which is a common bacterial infection. To avoid exposure to potentially contaminated human urine samples, we prepared artificial urine using easily acquired and affordable ingredients, which allowed less-experienced students to perform urinalysis without the risk of exposure to pathogenic organisms and ensured reliable availability of the urine samples. This practical class taught medical students how to use urinalysis data in conjunction with medical history to diagnose diseases from urine samples and to determine a treatment plan for clinical scenarios.

  17. Isolation of infectious Zika virus from a urine sample cultured in SIRC cells from a patient suspected of having rubella virus.

    PubMed

    Oliveira, Maria Isabel de; Namiyama, Gislene Mitsue; Cabral, Gabriela Bastos; Ferreira, João Leandro; Taniwaki, Noemi; Afonso, Ana Maria Sardinha; Lima, Isabella Rillo; Brigido, Luís Fernando Macedo de

    2018-01-01

    A great variety of viruses which cause exanthema share other clinical manifestations, making the etiologic identification a very difficult task, relying exclusively on the clinical examination. Rubella virus (RV) infection during the early stages of pregnancy can lead to serious birth defects, known as congenital rubella syndrome (CRS). In the present report, we described the presence of Zika virus (ZIKV) particles in urine samples and also ZIKV isolation in SIRC cells from the urine of a patient in acute phase of suspected rubella disease. The 50-year-old unvaccinated woman living in Sao Paulo, Brazil, was admitted to the emergency room with fever, headache, rash, arthralgia and prostration. Urine samples were collected for virus isolation and RT-qPCR. SIRC and Vero cells were inoculated with urine samples during 7 days. RT-qPCR was performed using measles virus (MV) and RV primers and both were found to be negative. After this result, RT-qPCR was performed for parvovirus B19, herpes virus 6 and ZIKV. The urine sample and the isolate were positive by Real Time PCR for ZIKV and negative for all other viruses tested. The sequences isolated are from the Asiatic lineage.

  18. A study of volatile contaminants in recovered water

    NASA Technical Reports Server (NTRS)

    Mckee, H. C.; Marek, R., Jr.

    1972-01-01

    The recovery and reuse of water during long term space flight is discussed. Particular attention was given to obtaining basic information on the volatile impurities in urine samples and in water recovered from urine by distillation. Data also cover laboratory distillation tests to determine the nature and extent of volatile constituents in the distillate and an evaluation of possible problems in distillation due to iodine used for control of microbial contamination. Efforts made to develop design criteria for distillation equipment to minimize the problems of volatile contaminants various methods which might be used for purification subsequent to recovery are included.

  19. Urine Collected From Diapers Can Be Used for 2-Dimensional Polyacrylamide Gel Electrophoresis (2D-PAGE) in Infants and Young Children

    PubMed Central

    Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon

    2011-01-01

    Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001

  20. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  1. Chemical characterization of territorial marking fluid of male Bengal tiger, Panthera tigris.

    PubMed

    Burger, B V; Viviers, M Z; Bekker, J P I; le Roux, M; Fish, N; Fourie, W B; Weibchen, G

    2008-05-01

    The territorial marking fluid of the male Bengal tiger, Panthera tigris, consists of a mixture of urine and a small quantity of lipid material that may act as a controlled-release carrier for the volatile constituents of the fluid. Using gas chromatography and gas chromatography-mass spectrometry, 98 volatile compounds and elemental sulfur were identified in the marking fluid. Another 16 volatiles were tentatively identified. The majority of these compounds were alkanols, alkanals, 2-alkanones, branched and unbranched alkanoic acids, dimethyl esters of dicarboxylic acids, gamma- and delta-lactones, and compounds containing nitrogen or sulfur. Several samples of the marking fluid contained pure (R)-3-methyl-2-octanone, (R)-3-methyl-2-nonanone, and (R)-3-methyl-2-decanone, but these ketones were partly or completely racemized in other samples. The gamma-lactone (S)-(+)-(Z)-6-dodecen-4-olide and the C(8) to C(16) saturated (R)-gamma-lactones and (S)-delta-lactones were present in high enantiomeric purities. The chiral carboxylic acids, 2-methylnonanoic acid, 2-methyldecanoic acid, 2-methylundecanoic acid, and 2-ethylhexanoic acid were racemates. Cadaverine, putrescine, and 2-acetylpyrroline, previously reported as constituents of tiger urine, were not detected. The dominant contribution of some ketones, fatty acids, and lactones to the composition of the headspace of the marking fluid suggests that these compounds may be important constituents of the pheromone. Although it constitutes only a small proportion, the lipid fraction of the fluid contained larger quantities of the volatile organic compounds than the aqueous fraction (urine). The lipid derives its role as controlled-release carrier of the chemical message left by the tiger, from its affinity for the volatiles of the marking fluid. Six proteins with masses ranging from 16 to 69 kDa, inter alia, the carboxylesterase-like urinary protein known as cauxin, previously identified in the urine of the domestic cat and other felid species, were identified in the urine fraction of the marking fluid.

  2. A validated UHPLC-MS/MS method to quantify low levels of anabolic-androgenic steroids naturally present in urine of untreated horses.

    PubMed

    Decloedt, Anneleen; Bailly-Chouriberry, Ludovic; Vanden Bussche, Julie; Garcia, Patrice; Popot, Marie-Agnes; Bonnaire, Yves; Vanhaecke, Lynn

    2015-06-01

    Doping control is a main priority for regulatory bodies of both the horse racing industry and the equestrian sports. Urine and blood samples are screened for the presence of hundreds of forbidden substances including anabolic-androgenic steroids (AASs). Based on the suspected endogenous origin of some AASs, with β-boldenone as the most illicit candidate, this study aimed to improve the knowledge of the naturally present AAS in horse urine. To this extent, a novel ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated according to the Association of Official Racing Chemists (AORC) and European Commission (EC) guidelines, proving the power of this new method. Low limits of detection (0.2 ng/mL), good reproducibility (percentage of standard deviation (%RSD) < 10%), high recovery (94.6 to 117.1%), selectivity and specificity, and a linear response (confirmed with R(2) > 0.99 and lack-of-fit analysis) were obtained for all included AASs. With this method, urine samples of 105 guaranteed untreated horses (47 geldings, 53 mares, and 5 stallions serving as a control) were screened for β-boldenone and five related natural steroids: androstadienedione (ADD), androstenedione (AED), alpha-testosterone (αT), beta-testosterone (βT), and progesterone (P). Progesterone, β-testosterone, and α-testosterone were detected in more than half of the horses at low concentrations (<2 ng/mL). Occasionally, not only testosterone and progesterone but also low concentrations of AED, ADD, and boldenone (Bol) were found (0.5-5 ng/mL). Graphical Abstract A sensitive, new and fully validated UHPLC-MS/MS method has been developed that is able to quantify low levels of anabolic-androgenic steroids naturally present in urine of untreated horses (mares and geldings).

  3. Essential and toxic element concentrations in blood and urine and their associations with diet: results from a Norwegian population study including high-consumers of seafood and game.

    PubMed

    Birgisdottir, B E; Knutsen, H K; Haugen, M; Gjelstad, I M; Jenssen, M T S; Ellingsen, D G; Thomassen, Y; Alexander, J; Meltzer, H M; Brantsæter, A L

    2013-10-01

    The first aim of the study was to evaluate calculated dietary intake and concentrations measured in blood or urine of essential and toxic elements in relation to nutritional and toxicological reference values. The second aim was to identify patterns of the element concentrations in blood and urine and to identify possible dietary determinants of the concentrations of these elements. Adults with a known high consumption of environmental contaminants (n=111), and a random sample of controls (n=76) answered a validated food frequency questionnaire (FFQ). Complete data on biological measures were available for 179 individuals. Blood and urine samples were analyzed for selenium, iodine, arsenic, mercury, cadmium and lead. Principal component analysis was used to identify underlying patterns of correlated blood and urine concentrations. The calculated intakes of selenium, iodine, inorganic arsenic and mercury were within guideline levels. For cadmium 24% of the high consumer group and 8% of the control group had intakes above the tolerable weekly intake. Concentrations of lead in blood exceeded the bench-mark dose lower confidence limits for some participants. However, overall, the examined exposures did not give rise to nutritional or toxicological concerns. Game consumption was associated with lead in blood (B(ln) 0.021; 95%CI:0.010, 0.031) and wine consumption. Seafood consumption was associated with urinary cadmium in non-smokers (B(ln) 0.009; 95%CI:0.003, 0.015). A novel finding was a distinct pattern of positively associated biological markers, comprising iodine, selenium, arsenic and mercury (eigenvalue 3.8), reflecting seafood intake (B 0.007; 95%CI:0.004, 0.010). The study clearly demonstrates the significance of seafood as a source of both essential nutrients and toxic elements simultaneously and shows that exposure to various essential and toxic elements can be intertwined. © 2013 Elsevier B.V. All rights reserved.

  4. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  5. The consequence of delayed fixation on subsequent preservation of urine cells.

    PubMed

    Ahmed, Hussain G; Tom, Murtada Am

    2011-01-01

    Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  6. Direct analysis of δ2H and δ18O in natural and enriched human urine using laser-based, Off-Axis Integrated Cavity Output Spectroscopy

    PubMed Central

    Berman, Elena S.F.; Fortsona, Susan L.; Snaith, Steven P.; Gupta, Manish; Baer, Douglas S.; Chery, Isabelle; Blanc, Stephane; Melanson, Edward L.; Thomson, Peter J; Speakman, John R.

    2012-01-01

    The stable isotopes of hydrogen (δ2H) and oxygen (δ18O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approx. 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ2H = −454 to +1702 ‰ and δ18O= −58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ2H and 0.09 ‰ 1σ for δ18O for natural urines, 1.1 ‰ 1σ for δ2H and 0.13 ‰ 1σ for δ18O for low enriched urines, and 1.0 ‰ 1σ for δ2H and 0.08 ‰ 1σ for δ18O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ2H and ±0.13 ‰ in δ18O (average deviation) against three independent IRMS laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken. PMID:23075099

  7. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  8. [Is the renal excretion of orally applied diatrizoate (Gastrografin) a reliable marker of gastrointestinal perforation or dehiscence of a gastrointestinal anastomosis?].

    PubMed

    Born, M; Axmann, C; Kader, R; von Falkenhausen, M; Manka, C; Willinek, W A; Schild, H

    2004-11-01

    Renal excretion of orally or rectally applied Gastrografin is reported to be a reliable indicator of a perforation or a postoperative anastomotic dehiscence of the GI-tract. The study was conducted to determine whether increased attenuation of the urine measured by CT after oral or rectal application of Gastrografin can give reliable evidence of any leakage from the gastrointestinal tract. Urine samples of 33 patients, who underwent a Gastrografin-enhanced fluoroscopic examination of the esophagus or the GI-tract for different clinical reasons, were examined by CT. The samples had been taken immediately before and 60 to 90 minutes after application of 100 ml Gastrografin. The results were compared with those of 5 healthy volunteers, who took urine samples before, 30, 60, 90, and 120 minutes after drinking 100 ml of Gastrografin. Maximal attenuation of the volunteers' urine samples was achieved 60 to 90 minutes after Gastrografin application with a mean of 50 Hounsfield units (HU), SD = 17 HU. The urine of three patients with radiologically proven fistula or dehiscence of a GI-tract anastomosis had no relevant increase in attenuation. Three other cases without any clinical or radiological evidence of an anastomotic leak had a substantial increase in the attenuation of the urine probes (87, 110, and 290 HU, respectively). The CT-measured urine samples as evidence of renal excretion of orally or rectally applied Gastrografin are not reliable for the detection of leaks from the GI-tract.

  9. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  10. Biomarkers for pulmonary injury following deployment

    DTIC Science & Technology

    2013-10-01

    construed as an official Department of the Army position, policy or decision unless so designated by other documentation. 2 REPORT DOCUMENTATION...cc x 3). BALF sample preparation for proteome analysis. Samples were thawed and desalted and concentrated with Amicon 3K MWCO spin filters (EMD...of the correlation heatmaps designate control and disease, respectively. Figure 2. PCA plot of BALF and urine datasets on left and right

  11. Urinary and breast milk biomarkers to assess exposure to naphthalene in pregnant women: an investigation of personal and indoor air sources

    PubMed Central

    2014-01-01

    Background Naphthalene exposures for most non-occupationally exposed individuals occur primarily indoors at home. Residential indoor sources include pest control products (specifically moth balls), incomplete combustion such as cigarette smoke, woodstoves and cooking, some consumer and building products, and emissions from gasoline sources found in attached garages. The study aim was to assess naphthalene exposure in pregnant women from Canada, using air measurements and biomarkers of exposure. Methods Pregnant women residing in Ottawa, Ontario completed personal and indoor air sampling, and questionnaires. During pregnancy, pooled urine voids were collected over two 24-hour periods on a weekday and a weekend day. At 2–3 months post-birth, they provided a spot urine sample and a breast milk sample following the 24-hour air monitoring. Urines were analyzed for 1-naphthol and 2-naphthol and breast milk for naphthalene. Simple linear regression models examined associations between known naphthalene sources, air and biomarker samples. Results Study recruitment rate was 11.2% resulting in 80 eligible women being included. Weekday and weekend samples were highly correlated for both personal (r = 0.83, p < 0.0001) and indoor air naphthalene (r = 0.91, p < 0.0001). Urine specific gravity (SG)-adjusted 2-naphthol concentrations collected on weekdays and weekends (r = 0.78, p < 0.001), and between pregnancy and postpartum samples (r = 0.54, p < 0.001) were correlated. Indoor and personal air naphthalene concentrations were significantly higher post-birth than during pregnancy (p < 0.0001 for signed rank tests); concurrent urine samples were not significantly different. Naphthalene in breast milk was associated with urinary 1-naphthol: a 10% increase in 1-naphthol was associated with a 1.6% increase in breast milk naphthalene (95% CI: 0.2%-3.1%). No significant associations were observed between naphthalene sources reported in self-administered questionnaires and the air or biomarker concentrations. Conclusions Median urinary concentrations of naphthalene metabolites tended to be similar to (1-naphthol) or lower (2-naphthol) than those reported in a Canadian survey of women of reproductive age. Only urinary 1-naphthol and naphthalene in breast milk were associated. Potential reasons for the lack of other associations include a lack of sources, varying biotransformation rates and behavioural differences over time. PMID:24767676

  12. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    PubMed

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.

  13. Phthalate metabolites in Norwegian mothers and children: Levels, diurnal variation and use of personal care products.

    PubMed

    Sakhi, Amrit Kaur; Sabaredzovic, Azemira; Cequier, Enrique; Thomsen, Cathrine

    2017-12-01

    Exposure to phthalates has been associated with reproductive and developmental toxicity. Data on levels of these compounds in the Norwegian population is limited. In this study, urine samples were collected from 48 mothers and their children in two counties in Norway. Eleven different phthalate metabolites originating from six commonly used phthalates in consumer products were determined. Concentrations of phthalate metabolites were significantly higher in children compared to mothers except for mono-ethyl phthalate (MEP). The mothers provided several urine samples during 24hours (h) and diurnal variation showed that the concentrations in the morning urine samples (24-8h) were significantly higher than at other time-periods for most of the phthalate metabolites. Intraclass correlation coefficients (ICCs) for 24-hour time-period were in the range of 0.49-0.81. These moderate to high ICCs indicate that one spot urine sample can be used to estimate the exposure to phthalates. Since a significant effect of time of day was observed, it is still advisable to standardize the collection time point to reduce the variation. For the mothers, the use of personal care products (PCPs) were less associated with morning urine samples than early day (8-12h) and evening (16-24h) urine samples. The use of perfume and hair products were positively associated with the urinary concentrations of low molecular weight phthalates. Use of shower soap and shampoo were positively associated with urinary concentration of di(2-ethylhexyl) phthalate (DEHP) metabolites. For children, face cream use was positively associated with phthalate metabolites in the morning samples, and hand soap use was negatively associated with concentration of urinary DEHP metabolites in afternoon/evening samples. Since different PCPs were associated with the urinary phthalate metabolites in different time-periods during a day, more than one spot urine sample might be required to study associations between urinary phthalate metabolites and the use of PCPs. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Application of multivariate statistics to the Steroidal Module of the Athlete Biological Passport: A proof of concept study.

    PubMed

    Alladio, Eugenio; Caruso, Roberto; Gerace, Enrico; Amante, Eleonora; Salomone, Alberto; Vincenti, Marco

    2016-05-30

    The Technical Document TD2014EAAS was drafted by the World Anti-Doping Agency (WADA) in order to fight the spread of endogenous anabolic androgenic steroids (EAAS) misuse in several sport disciplines. In particular, adoption of the so-called Athlete Biological Passport (ABP) - Steroidal Module allowed control laboratories to identify anomalous EAAS concentrations within the athletes' physiological urinary steroidal profile. Gas chromatography (GC) combined with mass spectrometry (MS), indicated by WADA as an appropriate technique to detect urinary EAAS, was utilized in the present study to develop and fully-validate an analytical method for the determination of all EAAS markers specified in TD2014EAAS, plus two further markers hypothetically useful to reveal microbial degradation of the sample. In particular, testosterone, epitestosterone, androsterone, etiocholanolone, 5α-androstane-3α,17β-diol, 5β-androstane-3α,17β-diol, dehydroepiandrosterone, 5α-dihydrotestosterone, were included in the analytical method. Afterwards, the multi-parametric feature of ABP profile was exploited to develop a robust approach for the detection of EAAS misuse, based on multivariate statistical analysis. In particular, Principal Component Analysis (PCA) was combined with Hotelling T(2) tests to explore the EAAS data obtained from 60 sequential urine samples collected from six volunteers, in comparison with a reference population of single urine samples collected from 96 volunteers. The new approach proved capable of identifying anomalous results, including (i) the recognition of samples extraneous to each of the individual urine series and (ii) the discrimination of the urine samples collected from individuals to whom "endogenous" steroids had been administrated with respect to the rest of the samples population. The proof-of-concept results presented in this study will need further extension and validation on a population of sport professionals. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Advantages of bioconjugated silica-coated nanoparticles as an innovative diagnosis for human toxoplasmosis.

    PubMed

    Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M

    2018-01-01

    Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily detected. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Coca tea consumption causes positive urine cocaine assay.

    PubMed

    Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy

    2006-12-01

    Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.

  17. Early morning urine collection to improve urinary lateral flow LAM assay sensitivity in hospitalised patients with HIV-TB co-infection.

    PubMed

    Gina, Phindile; Randall, Philippa J; Muchinga, Tapuwa E; Pooran, Anil; Meldau, Richard; Peter, Jonny G; Dheda, Keertan

    2017-05-12

    Urine LAM testing has been approved by the WHO for use in hospitalised patients with advanced immunosuppression. However, sensitivity remains suboptimal. We therefore examined the incremental diagnostic sensitivity of early morning urine (EMU) versus random urine sampling using the Determine® lateral flow lipoarabinomannan assay (LF-LAM) in HIV-TB co-infected patients. Consenting HIV-infected inpatients, screened as part of a larger prospective randomized controlled trial, that were treated for TB, and could donate matched random and EMU samples were included. Thus paired sample were collected from the same patient, LF-LAM was graded using the pre-January 2014, with grade 1 and 2 manufacturer-designated cut-points (the latter designated grade 1 after January 2014). Single sputum Xpert-MTB/RIF and/or TB culture positivity served as the reference standard (definite TB). Those treated for TB but not meeting this standard were designated probable TB. 123 HIV-infected patients commenced anti-TB treatment and provided matched random and EMU samples. 33% (41/123) and 67% (82/123) had definite and probable TB, respectively. Amongst those with definite TB LF-LAM sensitivity (95%CI), using the grade 2 cut-point, increased from 12% (5-24; 5/43) to 39% (26-54; 16/41) with random versus EMU, respectively (p = 0.005). Similarly, amongst probable TB, LF-LAM sensitivity increased from 10% (5-17; 8/83) to 24% (16-34; 20/82) (p = 0.001). LF-LAM specificity was not determined. This proof of concept study indicates that EMU could improve the sensitivity of LF-LAM in hospitalised TB-HIV co-infected patients. These data have implications for clinical practice.

  18. Studies on absorption and elimination of dietary maillard reaction products.

    PubMed

    Förster, Anke; Kühne, Yvonne; Henle, Thomas

    2005-06-01

    A nine-day dietary study involving 18 healthy volunteers was performed in order to investigate the influence of nutrition on the urinary excretion of the Maillard reaction products (MRPs) fructoselysine, pyrraline, and pentosidine. From day two through day eight, most types of Maillard product-containing food had to be avoided. On day five, participants were divided into four groups, three of them receiving a test meal (pretzel sticks, brewed coffee, or custard) containing defined amounts of MRPs. The fourth group served as a control. Urine samples taken over a 24-h period were analyzed for MRPs using chromatographic means. As a result of the MRP-free diet, urinary excretion of free pyrraline and fructoselysine, which was calculated from furosine analysis, were lowered about 90%. Excretion of pentosidine decreased about 40%. Consumption of pretzel sticks and coffee on day five resulted in increased amounts of pyrraline and pentosidine in urine samples on days five to seven. Related to the supplied amounts of pyrraline, about 50% were recovered in the urine samples after ingestion of the pretzel sticks. For pentosidine, 60% of the ingested free derivative from coffee brew and 2% of the peptide-bound amino acid ingested with the bakery product were recovered in the urine samples, indicating a better bioavailability for free pentosidine compared to the protein-bound form. For peptide-bound Amadori products, no influence on the excretion was observed after ingestion of the test foods, indicating degradation in the intestine or plasma to yet-unknown metabolites. In conclusion, differences concerning the excretion rate of individual MRPs point to individual resorption and metabolic pathways. These results are of importance for the discussion of a possible (patho)physiological role of dietary advanced glycation end products (AGEs).

  19. Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection.

    PubMed

    Almeida, C; Nogueira, J M F

    2006-06-16

    In this study, stir bar sorptive extraction and liquid desorption followed by high performance liquid chromatography with diode array detection (SBSE-LD-HPLC/DAD) were combined for the simultaneous determination of nine steroid sex hormones (estrone, 17alpha-estradiol, 17beta-estradiol, 17alpha-ethynylestradiol, diethylstilbestrol, mestranol, progesterone, 19-norethisterone and norgestrel) in water and urine matrices. During the method development, it has been demonstrated that equilibrium time, ionic strength and back extraction solvents are the most important parameters to control, for determining the nine-hormones in water matrices, in which stir bars coated with 126 microl of polydimethylsiloxane were used. Assays performed on 30 ml water samples spiked at 10 microg/l levels under optimised experimental conditions, yielded recoveries ranging from 11.1+/-4.9% (17beta-estradiol) to 100.2+/-10.4% (mestranol), showed that the methodology is well described by the octanol-water partition coefficients (K(PDMS/W) approximately K(O/W)) for the latter, while pronounced deviations to the theoretical efficiency (K(PDMS/W) not equal K(O/W)) were observed for the remaining hormones. From calibration studies, a good analytical performance for all hormones was attained, including a suitable precision (2.1-17.1%), low limits of detection (0.3-1.0 microg/l) and an excellent linear dynamic range (1.25-50.0 microg/l). Assays on environmental water and urine matrices showed recovery yields in worthy good agreement with the spiking level (10 microg/l), and suitability for profiling low microg/l levels of natural hormones in urine samples taken from pregnant women. The present methodology is easy, reliable and sensitive at the trace level, only requiring a low sample volume, showing to be a good analytical alternative to routine quality control for environmental and biomedical laboratories.

  20. Integrated next-generation sequencing of 16S rDNA and metaproteomics differentiate the healthy urine microbiome from asymptomatic bacteriuria in neuropathic bladder associated with spinal cord injury

    PubMed Central

    2012-01-01

    Background Clinical dogma is that healthy urine is sterile and the presence of bacteria with an inflammatory response is indicative of urinary tract infection (UTI). Asymptomatic bacteriuria (ABU) represents the state in which bacteria are present but the inflammatory response is negligible. Differentiating ABU from UTI is diagnostically challenging, but critical because overtreatment of ABU can perpetuate antimicrobial resistance while undertreatment of UTI can result in increased morbidity and mortality. In this study, we describe key characteristics of the healthy and ABU urine microbiomes utilizing 16S rRNA gene (16S rDNA) sequencing and metaproteomics, with the future goal of utilizing this information to personalize the treatment of UTI based on key individual characteristics. Methods A cross-sectional study of 26 healthy controls and 27 healthy subjects at risk for ABU due to spinal cord injury-related neuropathic bladder (NB) was conducted. Of the 27 subjects with NB, 8 voided normally, 8 utilized intermittent catheterization, and 11 utilized indwelling Foley urethral catheterization for bladder drainage. Urine was obtained by clean catch in voiders, or directly from the catheter in subjects utilizing catheters. Urinalysis, urine culture and 16S rDNA sequencing were performed on all samples, with metaproteomic analysis performed on a subsample. Results A total of 589454 quality-filtered 16S rDNA sequence reads were processed through a NextGen 16S rDNA analysis pipeline. Urine microbiomes differ by normal bladder function vs. NB, gender, type of bladder catheter utilized, and duration of NB. The top ten bacterial taxa showing the most relative abundance and change among samples were Lactobacillales, Enterobacteriales, Actinomycetales, Bacillales, Clostridiales, Bacteroidales, Burkholderiales, Pseudomonadales, Bifidobacteriales and Coriobacteriales. Metaproteomics confirmed the 16S rDNA results, and functional human protein-pathogen interactions were noted in subjects where host defenses were initiated. Conclusions Counter to clinical belief, healthy urine is not sterile. The healthy urine microbiome is characterized by a preponderance of Lactobacillales in women and Corynebacterium in men. The presence and duration of NB and method of urinary catheterization alter the healthy urine microbiome. An integrated approach of 16S rDNA sequencing with metaproteomics improves our understanding of healthy urine and facilitates a more personalized approach to prevention and treatment of infection. PMID:22929533

Top