Sample records for control water samples

  1. Preliminary post-tsunami water quality survey in Phang-Nga province, southern Thailand.

    PubMed

    Tharnpoophasiam, Prapin; Suthisarnsuntorn, Usanee; Worakhunpiset, Suwalee; Charoenjai, Prasasana; Tunyong, Witawat; Phrom-In, Suvannee; Chattanadee, Siriporn

    2006-01-01

    This preliminary water quality survey was performed eight weeks after the tsunami hit Phang-Nga Province on 26 December 2004. Water samples collected from the affected area, 10 km parallel to the seaside, were compared with water samples from the control area approximately 4 km from the seaside, which the tsunami waves could not reach. These samples included 18 surface-water samples, 37 well-water samples, and 8 drinking-water samples, which were examined for microbiology and physical-chemical properties. The microbiological examinations focused on enteric bacteria, which were isolated by culture method, while physical-chemical properties comprised on-site testing for pH, salinity, dissolved oxygen (DO), conductivity and total dissolved solids (TDS) by portable electrochemical meter (Sens Ion 156). The results of the microbiological examinations showed that water samples in the affected areas were more contaminated with enteric bacteria than the control area: 45.4% of surface-water samples in the affected area, and 40.0% in the control; 19.0% of well-water samples in the affected area, and 7.7% in the control. All eight drinking-water samples were clear of enteric bacteria. Tests for physical-chemical properties showed that the salinity, pH, conductivity, and TDS of surface-water samples from the affected area were significantly higher than the control. The salinity, conductivity, and TDS of the well-water samples from the affected areas were also significantly greater than those from the control area. The surface and well water in the tsunami-affected area have been changed greatly and need improvement.

  2. Quality-control design for surface-water sampling in the National Water-Quality Network

    USGS Publications Warehouse

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  3. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  4. Development of homologous viral internal controls for use in RT-PCR assays of waterborne enteric viruses.

    PubMed

    Parshionikar, Sandhya U; Cashdollar, Jennifer; Fout, G Shay

    2004-10-01

    Enteric viruses often contaminate water sources causing frequent outbreaks of gastroenteritis. Reverse transcription-polymerase chain reaction (RT-PCR) assays are commonly used for detection of human enteric viruses in environmental and drinking water samples. RT-PCR provides a means to rapidly detect low levels of these viruses, but it is sensitive to inhibitors that are present in water samples. Inhibitors of RT-PCR are concentrated along with viruses during sample processing. While procedures have been developed to remove inhibitors, none of them completely remove all inhibitors from all types of water matrices. This problem requires that adequate controls be used to distinguish true from potentially false-negative results. To address this problem, we have developed homologous viral internal controls for hepatitis A virus (HAV), poliovirus, Norwalk virus and rotavirus. These internal controls can be used in RT-PCR assays for the detection of the above viruses by competitive amplification, thereby allowing the detection of false negatives in processed water samples. The internal controls developed in this study were successfully tested with virus-seeded environmental water sample concentrates.

  5. Contained radiological analytical chemistry module

    DOEpatents

    Barney, David M.

    1989-01-01

    A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.

  6. Contained radiological analytical chemistry module

    DOEpatents

    Barney, David M.

    1990-01-01

    A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.

  7. Method and apparatus for sampling low-yield wells

    DOEpatents

    Last, George V.; Lanigan, David C.

    2003-04-15

    An apparatus and method for collecting a sample from a low-yield well or perched aquifer includes a pump and a controller responsive to water level sensors for filling a sample reservoir. The controller activates the pump to fill the reservoir when the water level in the well reaches a high level as indicated by the sensor. The controller deactivates the pump when the water level reaches a lower level as indicated by the sensors. The pump continuously activates and deactivates the pump until the sample reservoir is filled with a desired volume, as indicated by a reservoir sensor. At the beginning of each activation cycle, the controller optionally can select to purge an initial quantity of water prior to filling the sample reservoir. The reservoir can be substantially devoid of air and the pump is a low volumetric flow rate pump. Both the pump and the reservoir can be located either inside or outside the well.

  8. Quality-control results for ground-water and surface-water data, Sacramento River Basin, California, National Water-Quality Assessment, 1996-1998

    USGS Publications Warehouse

    Munday, Cathy; Domagalski, Joseph L.

    2003-01-01

    Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near the reporting limit. Surrogate recoveries for pesticides analyzed by gas chromatography/mass spectrometry (GC/MS), pesticides analyzed by high performance liquid chromatography (HPLC), and volatile organic compounds in ground- and surface-water samples were within the acceptable limits of 70 to 130 percent and median recovery values between 82 and 113 percent. The recovery percentages for surrogate compounds analyzed by HPLC had the highest standard deviation, 20 percent for ground-water samples and 16 percent for surface-water samples, and the lowest median values, 82 percent for ground-water samples and 91 percent for surface-water samples. Results were consistent with the recovery results described for the analytical methods. Field matrix spike recoveries for pesticide compounds analyzed using GC/MS in ground- and surface-water samples were comparable with published recovery data. Recoveries of carbofuran, a critical constituent in ground- and surface-water studies, and desethyl atrazine, a critical constituent in the ground-water study, could not be calculated because of problems with the analytical method. Recoveries of pesticides analyzed using HPLC in ground- and surface-water samples were generally low and comparable with published recovery data. Other methodological problems for HPLC analytes included nondetection of the spike compounds and estimated values of spike concentrations. Recovery of field matrix spikes for volatile organic compounds generally were within the acceptable range, 70 and 130 percent for both ground- and surface-water samples, and median recoveries from 62 to 127 percent. High or low recoveries could be related to errors in the field, such as double spiking or using spike solution past its expiration date, rather than problems during analysis. The methodological changes in the field spike protocol during the course of the Sacramento River Basin study, which included decreasing the amount of spike solu

  9. Reducing diarrhea through the use of household-based ceramic water filters: a randomized, controlled trial in rural Bolivia.

    PubMed

    Clasen, Thomas F; Brown, Joseph; Collin, Simon; Suntura, Oscar; Cairncross, Sandy

    2004-06-01

    Ceramic water filters have been identified as one of the most promising and accessible technologies for treating water at the household level. In a six-month trial, water filters were distributed randomly to half of the 50 participating households in a rural community in Bolivia; the remaining households continued to use customary water handling practices and served as controls. In four rounds of sampling following distribution of the filters, 100% of the 96 water samples from the filter households were free of thermotolerant coliforms compared with 15.5% of the control household samples. Diarrheal disease risk for individuals in intervention households was 70% lower than for controls (95% confidence interval [CI] = 53-80%; P < 0.001). For children less than five years old, the reduction in risk was 83% (95% CI = 51-94%; P < 0.001). These results show that affordable ceramic water filters enable low-income households to treat and maintain the microbiologic quality of their drinking water.

  10. Thermogravimetric analysis for the determination of water release rate from microcrystalline cellulose dry powder and wet bead systems.

    PubMed

    Mayville, Francis C; Wigent, Rodney J; Schwartz, Joseph B

    2006-01-01

    The purpose of this work was to determine the total amount of water contained in dry powder and wet bead samples of microcrystalline cellulose, MCC, (Avicel PH-101), taken from various stages of the extrusion/marumerization process used to make beads and to determine the kinetic rates of water release from each sample. These samples were allowed to equilibrate in controlled humidity chambers at 25 degrees C. The total amount of water in each sample, after equilibration, was determined by thermogravimetric analysis (TGA) as a function of temperature. The rates of water release from these samples were determined by using isothermal gravimetric analysis (ITGA) as a function of time. Analysis of the results for these studies suggest that water was released from these systems by several different kinetic mechanisms. The water release mechanisms for these systems include: zero order, second order, and diffusion controlled kinetics. It is believed that all three kinetic mechanisms will occur at the same time, however; only one mechanism will be prominent. The prominent mechanism was based on the amount of water present in the sample.

  11. Antibacterial Efficacy of Tender Coconut Water (Cocos nucifera L) on Streptococcus mutans: An In-Vitro Study

    PubMed Central

    Rukmini, J. N.; Manasa, Sunkari; Rohini, Chenna; Sireesha, Lavanya Putchla; Ritu, Sachan; Umashankar, G. K.

    2017-01-01

    Objective: The antibacterial property of coconut, the presence of lauric acid, and the ability to extract antimicrobial peptides Cn-AMP (1, 2, and 3) from tender coconut water has drawn attention on its effectiveness in normal consumption. An in-vitro experimental study was conducted to evaluate the antimicrobial efficacy of tender coconut water in its natural state on Streptococcus mutans. Materials and Methods: Fresh tender coconut water and pasteurized tender coconut water were taken as test samples, dimethyl formamide was used as the negative control, and 0.2% chlorhexidine was used as the positive control. Pure strain of S. mutans (MTCC 890) was used for determining the antibacterial effects. The test samples along with the controls were subjected to antimicrobial sensitivity test procedure and the zone of inhibition was examined. Kruskal–Wallis test was used to check for any significant differences in the antibacterial efficacy between the samples. Result: There was no zone of inhibition with the tender coconut water, fresh and pasteurised, and negative control (dimethyl formamide). Zone of inhibition was seen in positive control (0.2% Chlorhexidine). Conclusion: No antimicrobial activity was demonstrated with tender coconut water in its normal state (in vitro). PMID:28462183

  12. Antibacterial Efficacy of Tender Coconut Water (Cocos nucifera L) on Streptococcus mutans: An In-Vitro Study.

    PubMed

    Rukmini, J N; Manasa, Sunkari; Rohini, Chenna; Sireesha, Lavanya Putchla; Ritu, Sachan; Umashankar, G K

    2017-01-01

    The antibacterial property of coconut, the presence of lauric acid, and the ability to extract antimicrobial peptides Cn-AMP (1, 2, and 3) from tender coconut water has drawn attention on its effectiveness in normal consumption. An in-vitro experimental study was conducted to evaluate the antimicrobial efficacy of tender coconut water in its natural state on Streptococcus mutans . Fresh tender coconut water and pasteurized tender coconut water were taken as test samples, dimethyl formamide was used as the negative control, and 0.2% chlorhexidine was used as the positive control. Pure strain of S. mutans (MTCC 890) was used for determining the antibacterial effects. The test samples along with the controls were subjected to antimicrobial sensitivity test procedure and the zone of inhibition was examined. Kruskal-Wallis test was used to check for any significant differences in the antibacterial efficacy between the samples. There was no zone of inhibition with the tender coconut water, fresh and pasteurised, and negative control (dimethyl formamide). Zone of inhibition was seen in positive control (0.2% Chlorhexidine). No antimicrobial activity was demonstrated with tender coconut water in its normal state ( in vitro ).

  13. Dataset of producing and curing concrete using domestic treated wastewater

    PubMed Central

    Asadollahfardi, Gholamreza; Delnavaz, Mohammad; Rashnoiee, Vahid; Fazeli, Alireza; Gonabadi, Navid

    2015-01-01

    We tested the setting time of cement, slump and compressive and tensile strength of 54 triplicate cubic samples and 9 cylindrical samples of concrete with and without a Super plasticizer admixture. We produced concrete samples made with drinking water and treated domestic wastewater containing 300, 400 kg/m3 of cement before chlorination and then cured concrete samples made with drinking water and treated wastewater. Second, concrete samples made with 350 kg/m3 of cement with a Superplasticizer admixture made with drinking water and treated wastewater and then cured with treated wastewater. The compressive strength of all the concrete samples made with treated wastewater had a high coefficient of determination with the control concrete samples. A 28-day tensile strength of all the samples was 96–100% of the tensile strength of the control samples and the setting time was reduced by 30 min which was consistent with a ASTMC191 standard. All samples produced and cured with treated waste water did not have a significant effect on water absorption, slump and surface electrical resistivity tests. However, compressive strength at 21 days of concrete samples using 300 kg/m3 of cement in rapid freezing and thawing conditions was about 11% lower than concrete samples made with drinking water. PMID:26862577

  14. Dataset of producing and curing concrete using domestic treated wastewater.

    PubMed

    Asadollahfardi, Gholamreza; Delnavaz, Mohammad; Rashnoiee, Vahid; Fazeli, Alireza; Gonabadi, Navid

    2016-03-01

    We tested the setting time of cement, slump and compressive and tensile strength of 54 triplicate cubic samples and 9 cylindrical samples of concrete with and without a Super plasticizer admixture. We produced concrete samples made with drinking water and treated domestic wastewater containing 300, 400 kg/m(3) of cement before chlorination and then cured concrete samples made with drinking water and treated wastewater. Second, concrete samples made with 350 kg/m(3) of cement with a Superplasticizer admixture made with drinking water and treated wastewater and then cured with treated wastewater. The compressive strength of all the concrete samples made with treated wastewater had a high coefficient of determination with the control concrete samples. A 28-day tensile strength of all the samples was 96-100% of the tensile strength of the control samples and the setting time was reduced by 30 min which was consistent with a ASTMC191 standard. All samples produced and cured with treated waste water did not have a significant effect on water absorption, slump and surface electrical resistivity tests. However, compressive strength at 21 days of concrete samples using 300 kg/m(3) of cement in rapid freezing and thawing conditions was about 11% lower than concrete samples made with drinking water.

  15. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    PubMed

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  16. Sediment toxicity test results for the Urban Waters Study 2010, Bellingham Bay, Washington

    USGS Publications Warehouse

    Biedenbach, James M.

    2011-01-01

    The Washington Department of Ecology annually determines the quality of recently deposited sediments in Puget Sound as a part of Ecology's Urban Waters Initiative. The annual sediment quality studies use the Sediment Quality Triad (SQT) approach, thus relying on measures of chemical contamination, toxicity, and benthic in-faunal effects (Chapman, 1990). Since 2002, the studies followed a rotating sampling scheme, each year sampling a different region of the greater Puget Sound Basin. During the annual studies, samples are collected in locations selected with a stratified-random design, patterned after the designs previously used in baseline surveys completed during 1997-1999 (Long and others, 2003; Wilson and Partridge, 2007). Sediment samples were collected by personnel from the Washington Department of Ecology, in June of 2010 and shipped to the U. S. Geological Survey (USGS) laboratory in Corpus Christi, Texas (not shown), where the tests were performed. Sediment pore water was extracted with a pneumatic apparatus and was stored frozen. Just before testing, water-quality measurements were made and salinity adjusted, if necessary. Tests were performed on a dilution series of each sample consisting of 100-, 50-, and 25-percent pore-water concentrations. The specific objectives of this study were to: * Extract sediment pore water from a total of 30 sediment samples from the Bellingham Bay, Washington area within a day of receipt of the samples. * Measure water-quality parameters (salinity, dissolved oxygen, pH, sulfide, and ammonia) of thawed pore-water samples before testing and adjust salinity, temperature and dissolved oxygen, if necessary, to obtain optimal ranges for the test species. * Conduct the fertilization toxicity test with pore water using sea urchin (Stronylocentrotus purpuratus) (S. purpuratus) gametes. * Perform quality control assays with reference pore water, dilution blanks and a positive control dilution series with sodium dodecyl sulfate (SDS) in conjunction with each test. * Determine which samples caused a significant decrease in percent fertilization success relative to the negative control.

  17. Sachet water quality and brand reputation in two low-income urban communities in greater Accra, Ghana.

    PubMed

    Stoler, Justin; Tutu, Raymond A; Ahmed, Hawa; Frimpong, Lady Asantewa; Bello, Mohammed

    2014-02-01

    Sachet water has become an important primary source of drinking water in western Africa, but little is known about bacteriologic quality and improvements to quality control given the recent, rapid evolution of this industry. This report examines basic bacteriologic indicators for 60 sachet water samples from two very low-income communities in Accra, Ghana, and explores the relationship between local perceptions of brand quality and bacteriologic quality after controlling for characteristics of the vending environment. No fecal contamination was detected in any sample, and 82% of total heterotrophic bacteria counts were below the recommended limit for packaged water. Sachets from brands with a positive reputation for quality were 90% less likely to present any level of total heterotrophic bacteria after controlling for confounding factors. These results contrast with much of the recent sachet water quality literature and may indicate substantial progress in sachet water regulation and quality control.

  18. Sachet Water Quality and Brand Reputation in Two Low-Income Urban Communities in Greater Accra, Ghana

    PubMed Central

    Stoler, Justin; Tutu, Raymond A.; Ahmed, Hawa; Frimpong, Lady Asantewa; Bello, Mohammed

    2014-01-01

    Sachet water has become an important primary source of drinking water in western Africa, but little is known about bacteriologic quality and improvements to quality control given the recent, rapid evolution of this industry. This report examines basic bacteriologic indicators for 60 sachet water samples from two very low-income communities in Accra, Ghana, and explores the relationship between local perceptions of brand quality and bacteriologic quality after controlling for characteristics of the vending environment. No fecal contamination was detected in any sample, and 82% of total heterotrophic bacteria counts were below the recommended limit for packaged water. Sachets from brands with a positive reputation for quality were 90% less likely to present any level of total heterotrophic bacteria after controlling for confounding factors. These results contrast with much of the recent sachet water quality literature and may indicate substantial progress in sachet water regulation and quality control. PMID:24379244

  19. Effects of streambank fencing of pasture land on benthic macroinvertebrates and the quality of surface water and shallow ground water in the Big Spring Run basin of Mill Creek watershed, Lancaster County, Pennsylvania, 1993-2001

    USGS Publications Warehouse

    Galeone, Daniel G.; Brightbill, Robin A.; Low, Dennis J.; O'Brien, David L.

    2006-01-01

    Streambank fencing along stream channels in pastured areas and the exclusion of pasture animals from the channel are best-management practices designed to reduce nutrient and suspended-sediment yields from drainage basins. Establishment of vegetation in the fenced area helps to stabilize streambanks and provides better habitat for wildlife in and near the stream. This study documented the effectiveness of a 5- to 12-foot-wide buffer strip on the quality of surface water and near-stream ground water in a 1.42-mi2 treatment basin in Lancaster County, Pa. Two miles of stream were fenced in the basin in 1997 following a 3- to 4-year pre-treatment period of monitoring surface- and ground-water variables in the treatment and control basins. Changes in surface- and ground-water quality were monitored for about 4 years after fence installation. To alleviate problems in result interpretation associated with climatic and hydrologic variation over the study period, a nested experimental design including paired-basin and upstream/downstream components was used to study the effects of fencing on surface-water quality and benthic-macroinvertebrate communities. Five surface-water sites, one at the outlet of a 1.77-mi2 control basin (C-1), two sites in the treatment basin (T-3 and T-4) that were above any fence installation, and two sites (one at an upstream tributary site (T-2) and one at the outlet (T-1)) that were treated, were sampled intensively. Low-flow samples were collected at each site (approximately 25-30 per year at each site), and stormflow was sampled with automatic samplers at all sites except T-3. For each site where stormflow was sampled, from 35 to 60 percent of the storm events were sampled over the entire study period. Surface-water sites were sampled for analyses of nutrients, suspended sediment, and fecal streptococcus (only low-flow samples), with field parameters (only low-flow samples) measured during sample collection. Benthic-macroinvertebrate samples were collected in May and September of each year; samples were collected at the outlet of the control and treatment basins and at three upstream sites, two in the treatment basin and one in the control basin. For each benthic-macroinvertebrate sample: Stream riffles and pools were sampled using the kick-net method; habitat was characterized using Rapid Bioassessment Protocols (RBP); water-quality samples were collected for nutrients and suspended sediment; stream field parameters were measured; and multiple biological metrics were calculated. The experimental design to study the effects of fencing on the quality of near-stream shallow ground water involved a nested well approach. Two well nests were in the treatment basin, one each at surface-water sites T-1 and T-2. Within each well nest, the data from one deep well and three shallow wells (no greater than 12 ft deep) were used for regional characterization of ground-water quality. At each site, two of the shallow wells were inside the eventual fence (treated wells); the other shallow well was outside the eventual fence (control well). The wells were sampled monthly, primarily during periods with little to no recharge, for laboratory analysis of nutrients and fecal streptococcus; field parameters of water quality also were measured.

  20. Safe household water treatment and storage using ceramic drip filters: a randomised controlled trial in Bolivia.

    PubMed

    Clasen, T; Brown, J; Suntura, O; Collin, S

    2004-01-01

    A randomised controlled field trial was conducted to evaluate the effectiveness of ceramic drip filters to improve the microbiological quality of drinking water in a low-income community in rural Bolivia. In four rounds of water sampling over five months, 100% of the samples were free of thermotolerant (faecal) coliforms (TTC) compared to an arithmetic mean TTC count of 1517, 406, 167 and 245 among control households which continued to use their customary sources of drinking water. The filter systems produced water that consistently met WHO drinking-water standards despite levels of turbidity that presented a challenge to other low-cost POU treatment methods. The filter systems also demonstrated an ability to maintain the high quality of the treated water against subsequent re-contamination in the home.

  1. Pesticide residues analysis in water samples of Nagarpur and Saturia Upazila, Bangladesh

    NASA Astrophysics Data System (ADS)

    Hasanuzzaman, M.; Rahman, M. A.; Islam, M. S.; Salam, M. A.; Nabi, M. R.

    2018-03-01

    Pesticides used to protect the crops from pest attack in the agricultural fields pose harmful effect to the non-target organisms such as human and many other aquatic and terrestrial organisms either directly or indirectly through food chain. The present study was conducted to monitor a total of seven pesticide residues under organochlorine, organophosphorus and carbamate pesticides in three different sources of pond water, paddy field water and tube-well water from Nagarpur Upazila and paddy field water in the company of Dhaleshwari and Gazikhali river water from Saturia Upazila, Bangladesh. A total of 40 water samples were analyzed using high-performance liquid chromatography equipped with ultraviolet detector. Among the organophosphorus pesticides, diazinon was detected in eight water samples at a concentration ranging from 4.11 to 257.91 μg/l whereas, malathion was detected only in one water sample at a concentration of 84.64 μg/l and chlorpyrifos pesticide was also detected only in one water sample and the concentration was 37.3 μg/l. Trace amount of carbaryl was identified but it was below the detection limit. None of the tested water samples was found to be contaminated with DDT or its metabolites (DDE and DDD). The water samples contaminated with the suspected pesticides were above the acceptable limit except for the fish pond samples of Sahabatpur and Dubaria union. To control the misuse of pesticides and to reduce the possible health risk, appropriate control systems of pests such as integrated pest management system should be implemented immediately by the authorities of the country.

  2. Triangle area water supply monitoring project, October 1988 through September 2001, North Carolina -- description of the water-quality network, sampling and analysis methods, and quality-assurance practices

    USGS Publications Warehouse

    Oblinger, Carolyn J.

    2004-01-01

    The Triangle Area Water Supply Monitoring Project was initiated in October 1988 to provide long-term water-quality data for six area water-supply reservoirs and their tributaries. In addition, the project provides data that can be used to determine the effectiveness of large-scale changes in water-resource management practices, document differences in water quality among water-supply types (large multiuse reservoir, small reservoir, run-of-river), and tributary-loading and in-lake data for water-quality modeling of Falls and Jordan Lakes. By September 2001, the project had progressed in four phases and included as many as 34 sites (in 1991). Most sites were sampled and analyzed by the U.S. Geological Survey. Some sites were already a part of the North Carolina Division of Water Quality statewide ambient water-quality monitoring network and were sampled by the Division of Water Quality. The network has provided data on streamflow, physical properties, and concentrations of nutrients, major ions, metals, trace elements, chlorophyll, total organic carbon, suspended sediment, and selected synthetic organic compounds. Project quality-assurance activities include written procedures for sample collection, record management and archive, collection of field quality-control samples (blank samples and replicate samples), and monitoring the quality of field supplies. In addition to project quality-assurance activities, the quality of laboratory analyses was assessed through laboratory quality-assurance practices and an independent laboratory quality-control assessment provided by the U.S. Geological Survey Branch of Quality Systems through the Blind Inorganic Sample Project and the Organic Blind Sample Project.

  3. Dissolved pesticides, dissolved organic carbon, and water-quality characteristics in selected Idaho streams, April--December 2010

    USGS Publications Warehouse

    Reilly, Timothy J.; Smalling, Kelly L.; Wilson, Emma R.; Battaglin, William A.

    2012-01-01

    Water-quality samples were collected from April through December 2010 from four streams in Idaho and analyzed for a suite of pesticides, including fungicides, by the U.S. Geological Survey. Water samples were collected from two agricultural and two nonagricultural (control) streams approximately biweekly from the beginning of the growing season (April) through the end of the calendar year (December). Samples were analyzed for 90 pesticides using gas chromatography/mass spectrometry. Twenty-three pesticides, including 8 fungicides, 10 herbicides, 3 insecticides, and 2 pesticide degradates, were detected in 45 water samples. The most frequently detected compounds in the two agricultural streams and their detection frequencies were metolachlor, 96 percent; azoxystrobin, 79 percent; boscalid, 79 percent; atrazine, 46 percent; pendimethalin, 33 percent; and trifluralin, 33 percent. Dissolved-pesticide concentrations ranged from below instrumental limits of detection (0.5-1.0 nanograms per liter) to 771 nanograms per liter (hexazinone). The total number of pesticides detected in any given water sample ranged from 0 to 11. Only three pesticides (atrazine, fipronil, and simazine) were detected in samples from the control streams during the sampling period.

  4. Validation of internal controls for extraction and amplification of nucleic acids from enteric viruses in water samples.

    PubMed

    Hata, Akihiko; Katayama, Hiroyuki; Kitajima, Masaaki; Visvanathan, Chettiyappan; Nol, Chea; Furumai, Hiroaki

    2011-07-01

    Inhibitors that reduce viral nucleic acid extraction efficiency and interfere with cDNA synthesis and/or polymerase activity affect the molecular detection of viruses in aquatic environments. To overcome these significant problems, we developed a methodology for assessing nucleic acid yields and DNA amplification efficiencies for environmental water samples. This involved adding particles of adenovirus type 5 and murine norovirus and newly developed primer-sharing controls, which are amplified with the same primer pairs and result in the same amplicon sizes as the targets, to these samples. We found that nucleic acid loss during the extraction process, rather than reverse transcription-PCR (RT-PCR) inhibition, more significantly attributed to underestimation of the presence of viral genomes in the environmental water samples tested in this study. Our success rate for satisfactorily amplifying viral RNAs and DNAs by RT-PCR was higher than that for obtaining adequate nucleic acid preparations. We found that inhibitory properties were greatest when we used larger sample volumes. A magnetic silica bead-based RNA extraction method effectively removed inhibitors that interfere with viral nucleic acid extraction and RT-PCR. To our knowledge, this is the first study to assess the inhibitory properties of environmental water samples by using both control virus particles and primer-sharing controls.

  5. Enumeration of Somatic and F-RNA Phages as an Indicator of Fecal Contamination in Potable Water from Rural Areas of the North West Province.

    PubMed

    Nkwe, Keitumetse Idah; Ateba, Collins Njie; Sithebe, Nomathamsanqa Patricia; Bezuidenhout, Cornelius Carlos

    2015-07-01

    Bacteriophages are regarded as enteric viral indicators in faecally contaminated water systems and may indicate the presence of human viral pollution. They are relatively resistant to inactivation by natural and treatment processes. In this study, the presence of somatic coliphages and F-RNA coliphages was investigated in potable water from rural areas in the North West province. Water samples were aseptically collected from boreholes and tap water from some rural communities in the North West Province. Physical parameters of the water, such as the temperature, pH and turbidity, were measured before sample collection. Double-agar layer assay was performed using ISO, (1995, 2000) standard methods. Bottled water was used as a negative control and the strains фX174 and MS2 as positive controls. Of the 16 water samples collected, 15 were positive for somatic bacteriophages while F-RNA coliphages were detected in only two samples. Amongst the positive samples 189 and three plaque forming units were obtained for both somatic and F-RNA coliphages, respectively. No coliphage was detected in water from Masamane tap 1. The rest of the samples obtained from various rural areas were positive and did not comply with national and international standards for potable water. This was a cause for concern and should be further investigated.

  6. Enumeration of Somatic and F-RNA Phages as an Indicator of Fecal Contamination in Potable Water from Rural Areas of the North West Province

    PubMed Central

    Nkwe, Keitumetse Idah; Ateba, Collins Njie; Sithebe, Nomathamsanqa Patricia; Bezuidenhout, Cornelius Carlos

    2015-01-01

    Bacteriophages are regarded as enteric viral indicators in faecally contaminated water systems and may indicate the presence of human viral pollution. They are relatively resistant to inactivation by natural and treatment processes. In this study, the presence of somatic coliphages and F-RNA coliphages was investigated in potable water from rural areas in the North West province. Water samples were aseptically collected from boreholes and tap water from some rural communities in the North West Province. Physical parameters of the water, such as the temperature, pH and turbidity, were measured before sample collection. Double-agar layer assay was performed using ISO, (1995, 2000) standard methods. Bottled water was used as a negative control and the strains фX174 and MS2 as positive controls. Of the 16 water samples collected, 15 were positive for somatic bacteriophages while F-RNA coliphages were detected in only two samples. Amongst the positive samples 189 and three plaque forming units were obtained for both somatic and F-RNA coliphages, respectively. No coliphage was detected in water from Masamane tap 1. The rest of the samples obtained from various rural areas were positive and did not comply with national and international standards for potable water. This was a cause for concern and should be further investigated. PMID:26140675

  7. Effect of monochloramine treatment on the microbial ecology of Legionella and associated bacterial populations in a hospital hot water system.

    PubMed

    Baron, Julianne L; Harris, J Kirk; Holinger, Eric P; Duda, Scott; Stevens, Mark J; Robertson, Charles E; Ross, Kimberly A; Pace, Norman R; Stout, Janet E

    2015-05-01

    Opportunistic pathogens, including Legionella spp. and non-tuberculous mycobacteria, can thrive in building hot water systems despite municipal and traditional on-site chlorine disinfection. Monochloramine is a relatively new approach to on-site disinfection, but the microbiological impact of on-site chloramine use has not been well studied. We hypothesized that comparison of the microbial ecology associated with monochloramine treatment versus no on-site treatment would yield highly dissimilar bacterial communities. Hot water samples were collected monthly from 7 locations for three months from two buildings in a Pennsylvania hospital complex supplied with common municipal water: (1) a hospital administrative building (no on-site treatment) and (2) an adjacent acute-care hospital treated on-site with monochloramine to control Legionella spp. Water samples were subjected to DNA extraction, rRNA PCR, and 454 pyrosequencing. Stark differences in the microbiome of the chloraminated water and the control were observed. Bacteria in the treated samples were primarily Sphingomonadales and Limnohabitans, whereas Flexibacter and Planctomycetaceae predominated in untreated control samples. Serendipitously, one sampling month coincided with dysfunction of the on-site disinfection system that resulted in a Legionella bloom detected by sequencing and culture. This study also demonstrates the potential utility of high-throughput DNA sequencing to monitor microbial ecology in water systems. Copyright © 2015 Elsevier GmbH. All rights reserved.

  8. Ground-water sampling methods and quality-control data for the Red River of the North basin, Minnesota, North Dakota, and South Dakota, 1993-95

    USGS Publications Warehouse

    Menheer, M.A.; Brigham, M.E.

    1997-01-01

    Quality-control data demonstrated that most constituents measured for this study yielded reproducible data, with low to undetectable contamination from the sampling and analytical procedures. Several constituents were occasionally or frequently detected in blank samples at levels similar to low-concentration ground-water-quality samples. For example, iron was detected in 75 percent of the blank samples, with a maximum concentration of 27 [ig/L, indicating that iron contamination may interfere with its determination at low levels in ground waters. Copper, aluminum, and dissolved organic carbon concentrations in blank samples overlap those determined in ground-waterquality samples, thereby precluding quantitative reporting of those constituents. Most pesticide data are reproducible, with minimal bias. Some pesticides had low but consistent recoveries; these data may be useful if spike and surrogate data are carefully considered. Data for some pesticides measured in this study should not be quantitatively reported or used, because they may underestimate the concentrations of those pesticides in ground waters.

  9. Controls on the chemistry of runoff from an upland peat catchment

    NASA Astrophysics Data System (ADS)

    Worrall, Fred; Burt, Tim; Adamson, John

    2003-07-01

    This study uses 2 years of data from a detailed weekly water sampling programme in a 11·4 km2 upland peat catchment in the Northern Pennines, UK. The sampling comprised precipitation, soil-water samples and a number of streams, including the basin outlet. Samples were analysed for: pH, conductivity, alkalinity, Na, K, Ca, Mg, Fe, Al, Total N, SO4, Cl and colour. Principal component analysis (PCA) was used to identify end-members and compositional trends in order to identify controls on the development of water composition. The study showed that the direct use of PCA had several advantages over the use of end-member mixing analysis (EMMA) as it combines an analysis of mixing and evolving waters without the assumption of having to know the compositional sources of the water. In its application to an upland peat catchment, the study supports the view that shallow throughflow at the catotelm/acrotelm boundary is responsible for storm runoff generation and shows that baseflow is controlled by cation exchange in the catotelm and mixing with a base-rich groundwater.

  10. Groundwater-quality and quality-control data for two monitoring wells near Pavillion, Wyoming, April and May 2012

    USGS Publications Warehouse

    Wright, Peter R.; McMahon, Peter B.; Mueller, David K.; Clark, Melanie L.

    2012-01-01

    In June 2010, the U.S. Environmental Protection Agency installed two deep monitoring wells (MW01 and MW02) near Pavillion, Wyoming, to study groundwater quality. During April and May 2012, the U.S Geological Survey, in cooperation with the Wyoming Department of Environmental Quality, collected groundwater-quality data and quality-control data from monitoring well MW01 and, following well redevelopment, quality-control data for monitoring well MW02. Two groundwater-quality samples were collected from well MW01—one sample was collected after purging about 1.5 borehole volumes, and a second sample was collected after purging 3 borehole volumes. Both samples were collected and processed using methods designed to minimize atmospheric contamination or changes to water chemistry. Groundwater-quality samples were analyzed for field water-quality properties (water temperature, pH, specific conductance, dissolved oxygen, oxidation potential); inorganic constituents including naturally occurring radioactive compounds (radon, radium-226 and radium-228); organic constituents; dissolved gasses; stable isotopes of methane, water, and dissolved inorganic carbon; and environmental tracers (carbon-14, chlorofluorocarbons, sulfur hexafluoride, tritium, helium, neon, argon, krypton, xenon, and the ratio of helium-3 to helium-4). Quality-control sample results associated with well MW01 were evaluated to determine the extent to which environmental sample analytical results were affected by bias and to evaluate the variability inherent to sample collection and laboratory analyses. Field documentation, environmental data, and quality-control data for activities that occurred at the two monitoring wells during April and May 2012 are presented.

  11. EPA Technology Available for Licensing: Portable Device to Concentrate Water Samples for Microorganism Analysis

    EPA Pesticide Factsheets

    Using a computer controlled system, this ultrafiltration device automates the process of concentrating a water sample and can be operated in the field. The system was also designed to reduce human exposure to potentially contaminated water.

  12. Quantitative Analysis and Stability of the Rodenticide TETS ...

    EPA Pesticide Factsheets

    Journal Article The determination of the rodenticide tetramethylenedisulfotetramine (TETS) in drinking water is reportable through the use of automated sample preparation via solid phase extraction and detection using isotope dilution gas chromatography-mass spectrometry. The method was characterized over twenty-two analytical batches with quality control samples. Accuracies for low and high concentration quality control pools were 100 and 101%, respectively. The minimum reporting level (MRL) for TETS in this method is 0.50 ug/L. Five drinking waters representing a range of water quality parameters and disinfection practices were fortified with TETS at ten times the MRL and analyzed over a 28 day period to determine the stability of TETS in these waters. The amount of TETS measured in these samples averaged 100 ± 6% of the amount fortified suggesting that tap water samples may be held for up to 28 days prior to analysis.

  13. Release Mechanisms, Control Strategies, and Implementation Challenges of Controlling Lead in Drinking Water

    EPA Science Inventory

    Even minimally or moderately corrosive water can cause unacceptable and dangerous lead contamination to be released from common plumbing materials and devices into drinking water. Designing sampling programs to uncover the potential for ingestion of lead in water and to protect ...

  14. Continuous-flow water sampler for real-time isotopic water measurements

    NASA Astrophysics Data System (ADS)

    Carter, J.; Dennis, K.

    2013-12-01

    Measuring the stable isotopes of liquid water (δ18O and δD) is a tool familiar to many Earth scientists, but most current techniques require discrete sampling. For example, isotope ratio mass spectrometry requires the collection of aliquots of water that are then converted to CO2, CO or H2 for analysis. Similarly, laser-based techniques, such as Cavity Ring-Down Spectroscopy (CRDS) convert discrete samples (typically < 2μL) of liquid water to water vapor using a flash vaporization process. By requiring the use of discrete samples fine-scale spatial and temporal studies of changes in δ18O and δD are limited. Here we present a continuous-flow water sampler that will enable scientists to probe isotopic changes in real-time, with applications including, but not limited to, quantification of the 'amount effect' (Dansgaard, 1964) during an individual precipitation event or storm track, real-time mixing of water in river systems, and shipboard continuous water measurements (Munksgaard et al., 2012). Due to the inherent ability of CRDS to measure a continuous flow of water vapor it is an ideal candidate for interfacing with a continuous water sampling system. Here we present results from the first commercially available continuous-flow water sampler, developed by engineers at Picarro. This peripheral device is compatible with Picarro CRDS isotopic water analyzers, allowing real-time, continuous isotopic measurements of liquid water. The new device, which expands upon the design of Munskgaard et al. (2011), utilizes expanded polytetrafluoroethylene (ePTFE) membrane technology to continuously generate gas-phase water, while liquid water is pumped through the system. The water vapor subsequently travels to the CRDS analyzer where the isotopic ratios are measured and recorded. The generation of water vapor using membrane technology is sensitive to environmental conditions, which if not actively control, lead to sustainable experimental noise and drift. Consequently, our continuous-flow water sample employs active control for all pertinent parameters, significantly increasing its stability and usability. We will present data from controlled laboratory experiments demonstrating sample-to-sample precision and long-term stability. We will also show experimental data that highlights the instrumental sample-to-sample memory, which we have decreased significantly from previous implementations of this technology. Additionally, we will present field results from the Sacramento River, CA. Dansgaard, W. (1964) 'Stable isotopes in precipitation', Tellus, 16(4), p. 436-468. Munksgaard, N.C., Wurster, C.M., Bass, A., Zagorskis, I., and Bird, M.I. (2012) 'First continuous shipboard d18O and dD measurements in seawater by diffusion sampling--cavity ring-down spectrometry', Environmental Chemistry Letters, 10, p.301-307. Munksgaard, N.C., Wurster, C.M., and Bird, M.I., (2011), 'Continuous analysis of δ18O and δD values of water by diffusion sampling cavity ring-down spectrometry: a novel sampling device for unattended field monitoring of precipitation, ground and surface waters', Rapid Communications in Mass Spectrometry, 25, p. 3706-3712.

  15. Application of Ion Torrent Sequencing to the Assessment of the Effect of Alkali Ballast Water Treatment on Microbial Community Diversity

    PubMed Central

    Fujimoto, Masanori; Moyerbrailean, Gregory A.; Noman, Sifat; Gizicki, Jason P.; Ram, Michal L.; Green, Phyllis A.; Ram, Jeffrey L.

    2014-01-01

    The impact of NaOH as a ballast water treatment (BWT) on microbial community diversity was assessed using the 16S rRNA gene based Ion Torrent sequencing with its new 400 base chemistry. Ballast water samples from a Great Lakes ship were collected from the intake and discharge of both control and NaOH (pH 12) treated tanks and were analyzed in duplicates. One set of duplicates was treated with the membrane-impermeable DNA cross-linking reagent propidium mono-azide (PMA) prior to PCR amplification to differentiate between live and dead microorganisms. Ion Torrent sequencing generated nearly 580,000 reads for 31 bar-coded samples and revealed alterations of the microbial community structure in ballast water that had been treated with NaOH. Rarefaction analysis of the Ion Torrent sequencing data showed that BWT using NaOH significantly decreased microbial community diversity relative to control discharge (p<0.001). UniFrac distance based principal coordinate analysis (PCoA) plots and UPGMA tree analysis revealed that NaOH-treated ballast water microbial communities differed from both intake communities and control discharge communities. After NaOH treatment, bacteria from the genus Alishewanella became dominant in the NaOH-treated samples, accounting for <0.5% of the total reads in intake samples but more than 50% of the reads in the treated discharge samples. The only apparent difference in microbial community structure between PMA-processed and non-PMA samples occurred in intake water samples, which exhibited a significantly higher amount of PMA-sensitive cyanobacteria/chloroplast 16S rRNA than their corresponding non-PMA total DNA samples. The community assembly obtained using Ion Torrent sequencing was comparable to that obtained from a subset of samples that were also subjected to 454 pyrosequencing. This study showed the efficacy of alkali ballast water treatment in reducing ballast water microbial diversity and demonstrated the application of new Ion Torrent sequencing techniques to microbial community studies. PMID:25222021

  16. Application of ion torrent sequencing to the assessment of the effect of alkali ballast water treatment on microbial community diversity.

    PubMed

    Fujimoto, Masanori; Moyerbrailean, Gregory A; Noman, Sifat; Gizicki, Jason P; Ram, Michal L; Green, Phyllis A; Ram, Jeffrey L

    2014-01-01

    The impact of NaOH as a ballast water treatment (BWT) on microbial community diversity was assessed using the 16S rRNA gene based Ion Torrent sequencing with its new 400 base chemistry. Ballast water samples from a Great Lakes ship were collected from the intake and discharge of both control and NaOH (pH 12) treated tanks and were analyzed in duplicates. One set of duplicates was treated with the membrane-impermeable DNA cross-linking reagent propidium mono-azide (PMA) prior to PCR amplification to differentiate between live and dead microorganisms. Ion Torrent sequencing generated nearly 580,000 reads for 31 bar-coded samples and revealed alterations of the microbial community structure in ballast water that had been treated with NaOH. Rarefaction analysis of the Ion Torrent sequencing data showed that BWT using NaOH significantly decreased microbial community diversity relative to control discharge (p<0.001). UniFrac distance based principal coordinate analysis (PCoA) plots and UPGMA tree analysis revealed that NaOH-treated ballast water microbial communities differed from both intake communities and control discharge communities. After NaOH treatment, bacteria from the genus Alishewanella became dominant in the NaOH-treated samples, accounting for <0.5% of the total reads in intake samples but more than 50% of the reads in the treated discharge samples. The only apparent difference in microbial community structure between PMA-processed and non-PMA samples occurred in intake water samples, which exhibited a significantly higher amount of PMA-sensitive cyanobacteria/chloroplast 16S rRNA than their corresponding non-PMA total DNA samples. The community assembly obtained using Ion Torrent sequencing was comparable to that obtained from a subset of samples that were also subjected to 454 pyrosequencing. This study showed the efficacy of alkali ballast water treatment in reducing ballast water microbial diversity and demonstrated the application of new Ion Torrent sequencing techniques to microbial community studies.

  17. Hydrologic and water-quality data related to the occurrence of arsenic for areas along the Madison and Upper Missouri Rivers, southwestern and west-central Montana

    USGS Publications Warehouse

    Tuck, L.K.; Dutton, D.M.; Nimick, D.A.

    1997-01-01

    Geothermal waters in Yellowstone National Park contribute large quantities of arsenic to the headwaters of the Madison River. Water in some Quaternary and Tertiary valley-fill deposits along the Madison and upper Missouri Rivers also is locally enriched in arsenic. Arsenic in surface and ground water in these valleys is an important public- health concern because arsenic concentrations frequently exceed the State of Montana water- quality human health standard of 18 micrograms per liter as well as the U.S. Environmental Protection Agency Maximum Contaminant Level of 50 micrograms per liter. This report presents hydrologic and water-quality data for the Madison and upper Missouri Rivers and selected tributaries, irrigation supply canals or ditches, drains, springs and seeps, for Lake Helena, and for ground water in adjacent areas. Hydrologic and water-quality data were collected and compiled to provide information to more fully understand the extent, magnitude, and source of arsenic in surface and ground water along the Madison and upper Missouri Rivers; to assess, to the extent possible, the mechanisms that control arsenic concentrations; and to assess the effect of irrigation on arsenic concentrations. Hydrologic and arsenic- concentration data were collected by the U.S. Geological Survey and other agencies for 104 surface-water sites and 273 ground-water sites during this and previous studies. The quality of analytical results for arsenic concentrations was evaluated by quality-control samples that were submitted from the field and analyzed in the laboratory with routing samples. Quality-control samples consisted of replicates, standard reference samples, interlaboratory comparison samples, and field blanks.

  18. Bacteriological quality of drinking water from dispensers (coolers) and possible control measures.

    PubMed

    Baumgartner, Andreas; Grand, Marius

    2006-12-01

    Three water dispensers (coolers) were bacteriologically monitored over a period of 3 months to evaluate their hygienic status. For this purpose, 174 samples of chilled and unchilled water were analyzed for levels of mesophilic aerobic bacteria and the presence of Escherichia coli and enterococci in 100-ml samples, and the presence of Pseudomonas aeruginosa in 10- and 100-ml samples. Additionally, 12 samples from 20-liter plastic bottles of spring water used to supply the coolers and 36 samples of 12 different brands of noncarbonated bottled mineral water were similarly analyzed. Water from the coolers yielded aerobic plate counts of 3 to 5 log CFU/ml with a geometric mean of 3.86 log CFU/ml, whereas water from the 20-liter bottles had a mean aerobic plate count of 3.3 log CFU/ml. Aerobic plate counts for noncarbonated mineral waters were generally lower (13 samples, < 10 CFU/ml; 6 samples, 10 to 10(2) CFU/ml; 13 samples, 10(2) to 10(3) CFU/ml; 3 samples, 10(3) to 10(4) CFU/ ml; 1 sample, 2 x 10(4) CFU/ml). Although occasional professional cleaning of the coolers did not affect the aerobic plate count, P. aeruginosa was successfully eliminated 2 weeks after cleaning, with only one cooler becoming recolonized. Neither E. coli nor enterococci was found in any of the water samples tested. However, P. aeruginosa was identified in three (25%) of twelve 100-ml samples from 20-liter bottles of spring water; a similar frequency of 24.1% was seen for water samples from coolers. Overall, 35 (21.6%) of 162 water samples (10 ml) from coolers also yielded P. aeruginosa, suggesting potential growth of P. aeruginosa in the dispensers. Pulsed-field gel electrophoresis typing and antibiotic susceptibility testing found 19 P. aeruginosa isolates from the coolers and bottles to be identical, indicating that a single strain originated from the bottled water rather than the surroundings of the coolers. Because P. aeruginosa can cause serious nosocomial infections, its spread should be strictly controlled in institutions caring for vulnerable people such as hospitals and nursing homes. Consequently, in keeping with legal requirement for bottled spring and mineral water in Switzerland, it is also advisable that P. aeruginosa be absent in 100-ml samples of cooler water.

  19. Study design and percent recoveries of anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine, 2004-06

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Price, Curtis V.; Sandstrom, Mark W.

    2008-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS) began implementing Source Water-Quality Assessments (SWQAs) in 2002 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water). Finished water is the water that is treated, which typically involves, in part, the addition of chlorine or other disinfection chemicals to remove pathogens, and is ready to be delivered to consumers. Finished water is collected before the water enters the distribution system. This report describes the study design and percent recoveries of anthropogenic organic compounds (AOCs) with and without the addition of ascorbic acid to preserve water samples containing free chlorine. The percent recoveries were determined by using analytical results from a laboratory study conducted in 2004 by the USGS's National Water Quality Laboratory (NWQL) and from data collected during 2004-06 for a field study currently (2008) being conducted by the USGS's NAWQA Program. The laboratory study was designed to determine if preserving samples with ascorbic acid (quenching samples) adversely affects analytical performance under controlled conditions. During the laboratory study, eight samples of reagent water were spiked for each of five analytical schedules evaluated. Percent recoveries from these samples were then compared in two ways: (1) four quenched reagent spiked samples analyzed on day 0 were compared with four quenched reagent spiked samples analyzed on day 7 or 14, and (2) the combined eight quenched reagent spiked samples analyzed on day 0, 7, or 14 were compared with eight laboratory reagent spikes (LRSs). Percent recoveries from the quenched reagent spiked samples that were analyzed at two different times (day 0 and day 7 or 14) can be used to determine the stability of the quenched samples held for an amount of time representative of the normal amount of time between sample collection and analysis. The comparison between the quenched reagent spiked samples and the LRSs can be used to determine if quenching samples adversely affects the analytical performance under controlled conditions. The field study began in 2004 and is continuing today (February 2008) to characterize the effect of quenching on field-matrix spike recoveries and to better understand the potential oxidation and transformation of 277 AOCs. Three types of samples were collected from 11 NAWQA Study Units across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water spiked samples, and (3) nonquenched finished-water spiked samples. Percent recoveries of AOCs in quenched and nonquenched finished-water spiked samples collected during 2004-06 are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 6 surface-water and 7 ground-water quenched finished-water spiked samples paired with nonquenched finished-water spiked samples were analyzed. Analytical results for the field study are presented in two ways: (1) by surface-water supplies or ground-water supplies, and (2) by use (or source) group category for surface-water and ground-water supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water spiked samples also are presented.

  20. Data from exploratory sampling of groundwater in selected oil and gas areas of coastal Los Angeles County and Kern and Kings Counties in southern San Joaquin Valley, 2014–15: California oil, gas, and groundwater project

    USGS Publications Warehouse

    Dillon, David B.; Davis, Tracy A.; Landon, Matthew K.; Land, Michael T.; Wright, Michael T.; Kulongoski, Justin T.

    2016-12-09

    Exploratory sampling of groundwater in coastal Los Angeles County and Kern and Kings Counties of the southern San Joaquin Valley was done by the U.S. Geological Survey from September 2014 through January 2015 as part of the California State Water Resources Control Board’s Water Quality in Areas of Oil and Gas Production Regional Groundwater Monitoring Program. The Regional Groundwater Monitoring Program was established in response to the California Senate Bill 4 of 2013 mandating that the California State Water Resources Control Board design and implement a groundwater-monitoring program to assess potential effects of well-stimulation treatments on groundwater resources in California. The U.S. Geological Survey is in cooperation with the California State Water Resources Control Board to collaboratively implement the Regional Groundwater Monitoring Program through the California Oil, Gas, and Groundwater Project. Many researchers have documented the utility of different suites of chemical tracers for evaluating the effects of oil and gas development on groundwater quality. The purpose of this exploratory sampling effort was to determine whether tracers reported in the literature could be used effectively in California. This reconnaissance effort was not designed to assess the effects of oil and gas on groundwater quality in the sampled areas. A suite of water-quality indicators and geochemical tracers were sampled at groundwater sites in selected areas that have extensive oil and gas development. Groundwater samples were collected from a total of 51 wells, including 37 monitoring wells at 17 multiple-well monitoring sites in coastal Los Angeles County and 5 monitoring wells and 9 water-production wells in southern San Joaquin Valley, primarily in Kern and Kings Counties. Groundwater samples were analyzed for field waterquality indicators; organic constituents, including volatile and semi-volatile organic compounds and dissolved organic carbon indicators; naturally present inorganic constituents, including trace elements, nutrients, major and minor ions, and iron species; naturally present stable and radioactive isotopes; dissolved noble gases; dissolved standard and hydrocarbon gases, δ13C of methane, ethane, and δ2 H of methane. In total, 249 constituents and water-quality indicators were measured. Four types of quality-control samples (blanks, replicates, matrix spikes, and surrogates spiked in environmental and blank samples) were collected at approximately 10 percent of the wells. The quality-control data were used to determine whether the groundwater-sample data were of sufficient quality for the measured analytes to be used as potential indicators of oil and gas effects. The data from the 51 groundwater samples and from the quality-control samples are presented in this report.

  1. Detection of human enteric viruses in stream water with RT-PCR and cell culture.

    USGS Publications Warehouse

    Denis-Mize, K.; Fout, G.S.; Dahling, D.R.; Francy, D.S.

    2004-01-01

    A multiplex RT-PCR method was used to measure virus occurrence at five stream water sites that span a range of hydroclimatic, water-quality, and land-use characteristics. The performance of the molecular method was evaluated in comparison with traditional cell culture and Escherichia coli membrane filtration assays. The study incorporated multiple quality controls and included a control for virus recovery during the sampling procedure as well as controls to detect potentially false-negative and false-positive data. Poliovirus recovery ranged from 16 to 65% and was variable, even in samples collected within the same stream. All five sites were positive for viruses by both molecular and cell culture-based virus assays. Enteroviruses, reoviruses, rotaviruses, and hepatitis A viruses were detected, but the use of the quality controls proved critical for interpretation of the molecular data. All sites showed evidence of faecal contamination, and culturable viruses were detected in four samples that would have met the US Environmental Protection Agency's recommended E. coli guideline for safe recreational water.

  2. Ground-Water Quality Data in the San Francisco Bay Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Ray, Mary C.; Kulongoski, Justin T.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 620-square-mile San Francisco Bay study unit (SFBAY) was investigated from April through June 2007 as part of the Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground-water quality, as well as a statistically consistent basis for comparing water quality throughout California. Samples in SFBAY were collected from 79 wells in San Francisco, San Mateo, Santa Clara, Alameda, and Contra Costa Counties. Forty-three of the wells sampled were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Thirty-six wells were sampled to aid in evaluation of specific water-quality issues (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, trace elements, chloride and bromide isotopes, and uranium and strontium isotopes), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14 isotopes, and stable isotopes of hydrogen, oxygen, nitrogen, boron, and carbon), and dissolved noble gases (noble gases were analyzed in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blank samples, replicate samples, matrix spike samples) were collected for approximately one-third of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information from the field blanks resulted in applying 'V' codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). See the Appendix section 'Quality-Control-Sample Results'. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs were detected in about one-half of the grid wells, while pesticides were detected in about one-fifth of the grid wells. Concentrations of all VOCs and pesticides detected in samples from all SFBAY wells were below health-based thresholds. No pharmaceutical compounds were detected in any SFBAY well. One potential wastewater-indicator compound, caffeine, was detected in one grid well in SFBAY. Concentrations of most trace elements and nutrients detected in samples from all SFBAY wells were below health-based thresholds. Exceptions include nitrate, detected above the USEPA maximum contaminant level (MCL-US) in 3samples; arsenic, above the USEPA maximum contaminant level (MCL-US) in 3 samples; c

  3. Does quality of drinking water matter in kidney stone disease: A study in West Bengal, India.

    PubMed

    Mitra, Pubali; Pal, Dilip Kumar; Das, Madhusudan

    2018-05-01

    The combined interaction of epidemiology, environmental exposure, dietary habits, and genetic factors causes kidney stone disease (KSD), a common public health problem worldwide. Because a high water intake (>3 L daily) is widely recommended by physicians to prevent KSD, the present study evaluated whether the quantity of water that people consume daily is associated with KSD and whether the quality of drinking water has any effect on disease prevalence. Information regarding residential address, daily volume of water consumption, and source of drinking water was collected from 1,266 patients with kidney stones in West Bengal, India. Drinking water was collected by use of proper methods from case (high stone prevalence) and control (zero stone prevalence) areas thrice yearly. Water samples were analyzed for pH, alkalinity, hardness, total dissolved solutes, electrical conductivity, and salinity. Average values of the studied parameters were compared to determine if there were any statistically significant differences between the case and control areas. We observed that as many as 53.6% of the patients consumed <3 L of water daily. Analysis of drinking water samples from case and control areas, however, did not show any statistically significant alterations in the studied parameters. All water samples were found to be suitable for consumption. It is not the quality of water, rather the quantity of water consumed that matters most in the occurrence of KSD.

  4. The Quality of Water and Bottom Material in Lunga Reservoir, Virginia, September 2004 through August 2005

    USGS Publications Warehouse

    Lotspeich, R. Russell

    2007-01-01

    Lunga Reservoir is on the U.S. Marine Corps Base in Quantico, which is in the Potomac River basin and the Piedmont Physiographic Province of northern Virginia. Because of the potential use of the reservoir for scuba-diver training and public water supply in addition to current recreational activities, the U.S. Marine Corps wanted to know more about the water quality of Lunga Reservoir and how it compared to Virginia Department of Environmental Quality and Virginia State Water Control Board ambient water-quality standards. Water samples and physical properties were collected by the U.S. Geological Survey at 6 locations throughout Lunga Reservoir, and physical properties were collected at 11 additional locations in the reservoir from September 2004 through August 2005. Water samples for analysis of pesticides and bottom-material trace elements were collected once during the study at four of the sampling locations. Water temperature, dissolved-oxygen concentration, specific conductance, pH, and total chlorophyll concentration in Lunga Reservoir all had similar seasonal and spatial variations as in other lakes and reservoirs in this geographic region - thermal gradient in the summer and fall and isothermal conditions in the winter and early spring. Concentrations of water-quality indicators in Lunga Reservoir were within comparable levels of those in other reservoirs and did not violate the Virginia State Water Control Board standards for public water supplies. Water temperatures throughout Lunga Reservoir during the study period ranged from 4.4 to 30.1 degrees Celsius, well below the State Water Control Board maximum water temperature criteria of 32 degrees Celsius. Dissolved-oxygen concentrations ranged from 0.05 to 14.1 milligrams per liter throughout the reservoir during the study period, but never fell below the State Water Control Board minimum dissolved-oxygen criterion of 4.0 milligrams per liter at the surface of Lunga Reservoir. Specific conductance throughout Lunga Reservoir ranged from 29 to 173 microsiemens per centimeter at 25 degrees Celsius during the study period, with a mean specific conductance of 68 microsiemens per centimeter at 25 degrees Celsius. Measurements of pH throughout the reservoir ranged from 4.8 to 7.6 standard units. Concentrations of chemical constituents analyzed in Lunga Reservoir samples were below any State Water Control Board criteria and generally were similar in concentration to the same chemical constituents in other reservoirs in the State. Four water samples were analyzed for 54 pesticides, and none of these pesticides were above the laboratory minimum reporting level.

  5. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HANDLING QUALITY CONTROL SAMPLES IN THE FIELD (RTI/ACS-AP-209-090)

    EPA Science Inventory

    This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...

  6. Detection limit of Mycobacterium chimaera in water samples for monitoring medical device safety: insights from a pilot experimental series.

    PubMed

    Schreiber, P W; Köhler, N; Cervera, R; Hasse, B; Sax, H; Keller, P M

    2018-07-01

    A growing number of Mycobacterium chimaera infections after cardiosurgery have been reported by several countries. These potentially fatal infections were traced back to contaminated heater-cooler devices (HCDs), which use water as a heat transfer medium. Aerosolization of water contaminated with M. chimaera from HCDs enables airborne transmission to patients undergoing open chest surgery. Infection control teams test HCD water samples for mycobacterial growth to guide preventive measures. The detection limit of M. chimaera in water samples, however, has not previously been investigated. To determine the detection limit of M. chimaera in water samples using laboratory-based serial dilution tests. An M. chimaera strain representative of the international cardiosurgery-associated M. chimaera outbreak was used to generate a logarithmic dilution series. Two different water volumes, 50 and 1000mL, were inoculated, and, after identical processing (centrifugation, decantation, and decontamination), seeded on mycobacteria growth indicator tube (MGIT) and Middlebrook 7H11 solid media. MGIT consistently showed a lower detection limit than 7H11 solid media, corresponding to a detection limit of ≥1.44 × 10 4 cfu/mL for 50mL and ≥2.4cfu/mL for 1000mL water samples. Solid media failed to detect M. chimaera in 50mL water samples. Depending on water volume and culture method, major differences exist in the detection limit of M. chimaera. In terms of sensitivity, 1000mL water samples in MGIT media performed best. Our results have important implications for infection prevention and control strategies in mitigation of the M. chimaera outbreak and healthcare water safety in general. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. Guidance for the Development of Air Force Storm Water Sampling Programs

    DTIC Science & Technology

    1993-09-01

    38 Storm Water Quality Monitoring ................. 39 Determining Flow Rate ....................... 42 Weirs and Flumes... water quality monitoring it is not possible to analyze the entire nmoff from a drainage basin. The objective of water quality sampling is to collect a...development of storm water pollution prevention plans. Best management practices can also be developed to control the pollution sources identified. In storm

  8. Revelations of an overt water contamination.

    PubMed

    Singh, Gurpreet; Kaushik, S K; Mukherji, S

    2017-07-01

    Contaminated water sources are major cause of water borne diseases of public health importance. Usually, contamination is suspected after an increase in patient load. Two health teams investigated the episode. First team conducted sanitary survey, and second team undertook water safety and morbidity survey. On-site testing was carried out from source till consumer end. Investigation was also undertaken to identify factors which masked the situation. Prevention and control measures included super chlorination, provision of alternate drinking water sources, awareness campaign, layout of new water pipeline bypassing place of contamination, repair of sewers, flushing and cleaning of water pipelines, and repeated water sampling and testing. Multiple sources of drinking water supply were detected. Water samples from consumer end showed 18 coliforms per 100 ml. Sewer cross connection with active leakage in water pipeline was found and this was confirmed by earth excavation. Water safety and morbidity survey found majority of households receiving contaminated water supply. This survey found no significant difference among households receiving contaminated water supply and those receiving clean water. Average proportion of household members with episode of loose motions, pain abdomen, vomiting, fever, and eye conditions was significantly more among households receiving contaminated water. The present study documents detailed methodology of investigation and control measures to be instituted on receipt of contaminated water samples. Effective surveillance mechanisms for drinking water supplies such as routine testing of water samples can identify water contamination at an early stage and prevent an impending outbreak.

  9. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    PubMed Central

    Heinz, Emanuel; Kraft, Philipp; Buchen, Caroline; Frede, Hans-Georg; Aquino, Eugenio; Breuer, Lutz

    2014-01-01

    We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water) in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS) for stable water isotope analysis (δ2H and δ18O), a reagentless hyperspectral UV photometer (ProPS) for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines) in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system's technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season. PMID:24366178

  10. Method of Analysis by the U.S. Geological Survey California District Sacramento Laboratory-- Determination of Dissolved Organic Carbon in Water by High Temperature Catalytic Oxidation, Method Validation, and Quality-Control Practices

    USGS Publications Warehouse

    Bird, Susan M.; Fram, Miranda S.; Crepeau, Kathryn L.

    2003-01-01

    An analytical method has been developed for the determination of dissolved organic carbon concentration in water samples. This method includes the results of the tests used to validate the method and the quality-control practices used for dissolved organic carbon analysis. Prior to analysis, water samples are filtered to remove suspended particulate matter. A Shimadzu TOC-5000A Total Organic Carbon Analyzer in the nonpurgeable organic carbon mode is used to analyze the samples by high temperature catalytic oxidation. The analysis usually is completed within 48 hours of sample collection. The laboratory reporting level is 0.22 milligrams per liter.

  11. Sampling. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Carnegie, John W.

    A brief overview of the basic concepts and philosophies for sampling water and waste water systems is presented in this module. The module is not intended to specify sampling procedures, frequencies, or locations for specific treatment facilities but rather to outline those general procedures which should be followed when sampling under most…

  12. Low-noise humidity controller for imaging water mediated processes in atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaponenko, I., E-mail: iaroslav.gaponenko@unige.ch; Gamperle, L.; Herberg, K.

    2016-06-15

    We demonstrate the construction of a novel low-noise continuous flow humidity controller and its integration with a commercial variable-temperature atomic force microscope fluid cell, allowing precise control of humidity and temperature at the sample during nanoscale measurements. Based on wet and dry gas mixing, the design allows a high mechanical stability to be achieved by means of an ultrasonic atomiser for the generation of water-saturated gas, improving upon previous bubbler-based architectures. Water content in the flow is measured both at the inflow and outflow of the fluid cell, enabling the monitoring of water condensation and icing, and allowing controlled variationmore » of the sample temperature independently of the humidity. To benchmark the performance of the controller, the results of detailed noise studies and time-based imaging of the formation of ice layers on highly oriented pyrolytic graphite are shown.« less

  13. Ground-water appraisal in northwestern Big Stone County, west-central Minnesota

    USGS Publications Warehouse

    Soukup, W.G.

    1980-01-01

    Samples of water were collected for chemical analysis from wells in the surficial outwash, buried outwash, and Cretaceous aquifers. With the exception of nitrate, the greatest difference in chemical quality was between samples from the buried outwash and Cretaceous aquifers. Water from Cretaceous aquifers is softer than water from the outwash aquifers, but contains concentrations of sodium and boron that are high enough to damage soils and crops if used for irrigation. Nitrate concentrations exceeded the Minnesota Pollution Control Agency's recommended limits for drinking water in one sample from the surficial aquifer.

  14. Thermal Battery Operating Gas Atmosphere Control and Heat Transfer Optimization

    DTIC Science & Technology

    2012-09-01

    volume of water vapor present at 21.8 C in sample bottles std atm cc 1.533645 Maximum volume of water vapor present at 21.8 C in gas handling system and...sample bottles std atm cc Comparison of gas volumes measured at 838.197 and 1682.297 seconds shows that no water vapor was present and that the gas reacted...temperature of 22.0 ºC torr 0.241556 Maximum volume of water vapor present in one sample bottle std atm cc 0.000194 Maximum weight of water vapor present

  15. Genotoxicity Assessment of Water Samples from the Sungai Dua River in Pulau Pinang, Malaysia, Using the Allium cepa Test

    PubMed Central

    Akinboro, Akeem; Mohammed, Kamaruzaman; Rathnasamy, Selestin; Muniandy, Vijay Raj

    2011-01-01

    Unwanted side effects from a polluted water body may not be limited to the flora and fauna, they may also be transferred to the organisms along the food chain. Four water samples collected immediately and five days after rainfall from two locations inside the polluted Sungai Dua River (SGD) were tested for toxicity using the Allium cepa assay. The samples were analysed for metal content and were both macroscopically and microscopically evaluated. The water samples contained more sodium (Na+) and calcium (Ca2+) than the control tap water, and they showed root growth and mitotic inhibitions (MI) in A. cepa. However, the inhibitory effects were not dose-dependent. No chromosomal aberration (CA) was induced at 100.00% (undiluted water sample). These results suggest the water samples from SGD had weak mitodepressive and genotoxic effects on the A. cepa cells. PMID:24575215

  16. A Randomized Controlled Trial to Measure Spillover Effects of a Combined Water, Sanitation, and Handwashing Intervention in Rural Bangladesh.

    PubMed

    Benjamin-Chung, Jade; Amin, Nuhu; Ercumen, Ayse; Arnold, Benjamin F; Hubbard, Alan E; Unicomb, Leanne; Rahman, Mahbubur; Luby, Stephen P; Colford, John M

    2018-03-27

    Water, sanitation, and handwashing interventions may confer spillover effects on neighbors of intervention recipients by interrupting pathogen transmission. We measured geographically local spillovers in WASH Benefits, a cluster-randomized trial in rural Bangladesh, by comparing outcomes among neighbors of intervention vs. control participants. WASH Benefits randomly allocated geographically-defined clusters to a compound-level intervention (chlorinated drinking water, upgraded sanitation, and handwashing promotion) or control. From January to August 2015, in 180 clusters, we enrolled 1,799 neighboring children age-matched to trial participants that would have been eligible for WASH Benefits had they been conceived slightly earlier or later. After 28 months of intervention, we quantified fecal indicator bacteria in toy rinse and drinking water samples, measured soil-transmitted helminth infections, and recorded caregiver-reported diarrhea and respiratory illness. Neighbors' characteristics were balanced across arms. The prevalence of detectable E. coli in tubewell samples was lower for neighbors of intervention vs. control trial participants (prevalence ratio = 0.83; 0.73, 0.95). There was no difference in fecal indicator bacteria prevalence between arms for other environmental samples. Prevalence was similar in neighbors of intervention vs. control participants for soil-transmitted helminth infection, diarrhea, and respiratory illness. A compound-level water, sanitation, and handwashing intervention reduced neighbors' tubewell water contamination but did not impact neighboring children's health.

  17. Impact of refined petroleum spills on water quality, macro-invertebrate and microbial communities of a tropical aquatic environment.

    PubMed

    Chukwu, L O; Nwachukwu, S C U

    2005-07-01

    Water quality characteristics, benthic macro-invertebrates and microbial communities of three first order streams in South West Nigeria were investigated to assess the effects of refined petroleum five months after spillage. All physical and chemical conditions except temperature and pH were significantly different (P<0.01) at the upstream control stations and impacted stations reflecting the perturbational stress. The benthic macro-invertebrate fauna were dominated by arthropods, but the faunal spectrum was dissimilar at all the stations studied. Sampling stations at the epicentre of the spill showed considerable reduction in faunal compositions and relative abundance. Generally, the microbial density and diversity were highest in both soil and water samples from impacted sites than in control sites. There was a significantly higher proportion (P < 0.05) of hydrocarbon utilizers in soil than in water samples in all stations except in samples from stations (P<0.05).

  18. Integrated Seawater Sampler and Data Acquisition System Prototype

    DTIC Science & Technology

    1993-04-01

    circuitry. The sample bags, initially sealed in a chemically clean environment , were opened by pumping the water out of the tray, thus forcing water into...the water sample containers from materials having low metals content. Control of the sample transfer environment through the use of Class-100 clean... environment . CTD designers also intended their underwater units and deck terminals to be connected directly together providing AC grounding appropriate to

  19. Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

    1998-10-01

    The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samplesmore » were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.« less

  20. WATER TREATMENT

    DOEpatents

    Pitman, R.W.; Conley, W.R. Jr.

    1962-12-01

    An automated system for adding clarifying chemicals to water in a water treatment plant is described. To a sample of the floc suspension polyacrylamide or similar filter aid chemicals are added, and the sample is then put through a fast filter. The resulting filtrate has the requisite properties for monitoring in an optical turbidimeter to control the automated system. (AEC)

  1. Results and Conclusions from the NASA Isokinetic Total Water Content Probe 2009 IRT Test

    NASA Technical Reports Server (NTRS)

    Reehorst, Andrew; Brinker, David

    2010-01-01

    The NASA Glenn Research Center has developed and tested a Total Water Content Isokinetic Sampling Probe. Since, by its nature, it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument comprises the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Results and conclusions are presented from probe tests in the NASA Glenn Icing Research Tunnel (IRT) during January and February 2009. The use of reference probe heat and the control of air pressure in the water vapor measurement subsystem are discussed. Several run-time error sources were found to produce identifiable signatures that are presented and discussed. Some of the differences between measured Isokinetic Total Water Content Probe and IRT calibration seems to be caused by tunnel humidification and moisture/ice crystal blow around. Droplet size, airspeed, and liquid water content effects also appear to be present in the IRT calibration. Based upon test results, the authors provide recommendations for future Isokinetic Total Water Content Probe development.

  2. Summary of inorganic compositional data for groundwater, soil-water, and surface-water samples collected at the Headgate Draw subsurface drip irrigation site, Johnson County, Wyoming

    USGS Publications Warehouse

    Geboy, Nicholas J.; Engle, Mark A.; Schroeder, Karl T.; Zupancic, John W.

    2011-01-01

    As part of a 5-year project on the impact of subsurface drip irrigation (SDI) application of coalbed-methane (CBM) produced waters, water samples were collected from the Headgate Draw SDI site in the Powder River Basin, Wyoming, USA. This research is part of a larger study to understand short- and long-term impacts on both soil and water quality from the beneficial use of CBM waters to grow forage crops through use of SDI. This document provides a summary of the context, sampling methodology, and quality assurance and quality control documentation of samples collected prior to and over the first year of SDI operation at the site (May 2008-October 2009). This report contains an associated database containing inorganic compositional data, water-quality criteria parameters, and calculated geochemical parameters for samples of groundwater, soil water, surface water, treated CBM waters, and as-received CBM waters collected at the Headgate Draw SDI site.

  3. Does quality of drinking water matter in kidney stone disease: A study in West Bengal, India

    PubMed Central

    Mitra, Pubali; Pal, Dilip Kumar

    2018-01-01

    Purpose The combined interaction of epidemiology, environmental exposure, dietary habits, and genetic factors causes kidney stone disease (KSD), a common public health problem worldwide. Because a high water intake (>3 L daily) is widely recommended by physicians to prevent KSD, the present study evaluated whether the quantity of water that people consume daily is associated with KSD and whether the quality of drinking water has any effect on disease prevalence. Materials and Methods Information regarding residential address, daily volume of water consumption, and source of drinking water was collected from 1,266 patients with kidney stones in West Bengal, India. Drinking water was collected by use of proper methods from case (high stone prevalence) and control (zero stone prevalence) areas thrice yearly. Water samples were analyzed for pH, alkalinity, hardness, total dissolved solutes, electrical conductivity, and salinity. Average values of the studied parameters were compared to determine if there were any statistically significant differences between the case and control areas. Results We observed that as many as 53.6% of the patients consumed <3 L of water daily. Analysis of drinking water samples from case and control areas, however, did not show any statistically significant alterations in the studied parameters. All water samples were found to be suitable for consumption. Conclusions It is not the quality of water, rather the quantity of water consumed that matters most in the occurrence of KSD. PMID:29744472

  4. Low zinc in drinking water is associated with the risk of type 1 diabetes in children.

    PubMed

    Samuelsson, Ulf; Oikarinen, Sami; Hyöty, Heikki; Ludvigsson, Johnny

    2011-05-01

    To explore if drinking water may influence the development of type 1 diabetes in children, either via enterovirus spread via drinking water or quality of drinking water related to acidity or concentration of certain minerals. One hundred and forty-two families with a child with diabetes and who lived either in seven municipalities with a high annual diabetes incidence during 1977-2001 and in six municipalities with the lowest incidence during those 25 yr were asked to participate. Three hundred and seventy-three families in these communities were used as controls. The families filled a 200-mL plastic bottle with their tap drinking water and returned it by mail. The water samples were analyzed for pH, zinc, iron, nitrate, nitrite, nitrate-nitrogen and nitrite-nitrogen, and occurrence of enterovirus RNA. Enterovirus RNA was not found in the tap water samples. The concentration of zinc, nitrate, and nitrate-nitrogen was lower in the municipalities with high incidence of type 1 diabetes. The water samples from families with a child with diabetes had lower concentration of zinc than water samples from control families. Low zinc in drinking water is associated with the risk of developing type 1 diabetes during childhood. Enterovirus does not seem to be spread via drinking water in a country with modern water works. © 2010 John Wiley & Sons A/S.

  5. Drinking water: a risk factor for high incidence of esophageal cancer in Anyang, China.

    PubMed

    Cao, Wenbo; Han, Jianying; Yuan, Yi; Xu, Zhixiang; Yang, Shengli; He, Weixin

    2016-06-01

    Anyang is known to be a high-incidence area of esophageal cancer (EC) in China. Among a long list of risk factors, the quality of drinking water was evaluated. We have selected 3806 individuals and collected 550 drinking water samples correspondent with this not-matched case-control survey. There are 531 EC patients included based on Population Cancer Registry from 92 townships, of which 3275 controls with long-lived aged over 90 years and free from EC are used as controls in the same regions. Our result suggests that the quality of drinking water is a highly associated risk factor for EC. The residential ecological environment and the quality of water resource positively link with each other. The analysis of water samples also demonstrated that the concentrations of methyl ethylamine, morpholine, N-methylbenzylamine, nitrate and chloride in water from springs and rivers are higher than those in well and tap water (P = 0.001). Micronuclei formation tests show that well water and tap water in these regions have no mutagenicity.

  6. Sampling for Lead in Drinking Water

    EPA Science Inventory

    Sampling protocols for lead in water can be broadly categorized based on their intended purpose of 1) Pb regulatory compliance/corrosion control efficacy, 2) Pb plumbing source determination or Pb type identification, and 3) Pb exposure assessment. Choosing the appropriate protoc...

  7. Occurrence of pharmaceuticals in a water supply system and related human health risk assessment.

    PubMed

    de Jesus Gaffney, Vanessa; Almeida, Cristina M M; Rodrigues, Alexandre; Ferreira, Elisabete; Benoliel, Maria João; Cardoso, Vitor Vale

    2015-04-01

    A monitoring study of 31 pharmaceuticals along Lisbon's drinking water supply system was implemented, which comprised the analysis of 250 samples including raw water (surface water and groundwater), and drinking water. Of the 31 pharmaceutical compounds, only sixteen were quantified in the analyzed samples, with levels ranging from 0.005 to 46 ng/L in raw water samples and 0.09-46 ng/L in drinking water samples. The human health risk assessment performed showed that appreciable risks to the consumer's health arising from exposure to trace levels of pharmaceuticals in drinking water are extremely unlikely, as RQs values were all below 0.001. Also, pharmaceuticals were selected as indicators to be used as a tool to control the quality of raw water and the treatment efficiency in the drinking water treatment plants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Ground-Water Quality Data in the Southern Sierra Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Fram, Miranda S.; Belitz, Kenneth

    2007-01-01

    Ground-water quality in the approximately 1,800 square-mile Southern Sierra study unit (SOSA) was investigated in June 2006 as part of the Statewide Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Southern Sierra study was designed to provide a spatially unbiased assessment of raw ground-water quality within SOSA, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from fifty wells in Kern and Tulare Counties. Thirty-five of the wells were selected using a randomized grid-based method to provide statistical representation of the study area, and fifteen were selected to evaluate changes in water chemistry along ground-water flow paths. The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, pharmaceutical compounds, and wastewater-indicator compounds], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), and 1,2,3-trichloropropane (1,2,3-TCP)], naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water], and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected for approximately one-eighth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information resulted in censoring of less than 0.2 percent of the data collected for ground-water samples. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs and pesticides were detected in less than one-third of the grid wells, and all detections in samples from SOSA wells were below health-based thresholds. All detections of trace elements and nutrients in samples from SOSA wells were below health-based thresholds, with the exception of four detections of arsenic that were above the USEPA maximum contaminant level (MCL-US) and one detection of boron that was above the CDPH notification level (NL-CA). All detections of radioactive constituents were below health-based thresholds, although four samples had activities of radon-222 above the proposed MCL-US. Most of the samples from SOSA wells had concentrations of major elements, total dissolved solids, and trace elements below the non-enforceable thresholds set for aesthetic concerns. A few samples contained iron, manganese, or total dissolved solids at concentrations above the SMCL-CA thresholds.

  9. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York--July 1999 through June 2001

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.

  10. Method of analysis at the U.S. Geological Survey California Water Science Center, Sacramento Laboratory - determination of haloacetic acid formation potential, method validation, and quality-control practices

    USGS Publications Warehouse

    Zazzi, Barbara C.; Crepeau, Kathryn L.; Fram, Miranda S.; Bergamaschi, Brian A.

    2005-01-01

    An analytical method for the determination of haloacetic acid formation potential of water samples has been developed by the U.S. Geological Survey California Water Science Center Sacramento Laboratory. The haloacetic acid formation potential is measured by dosing water samples with chlorine under specified conditions of pH, temperature, incubation time, darkness, and residual-free chlorine. The haloacetic acids formed are bromochloroacetic acid, bromodichloroacetic acid, dibromochloroacetic acid, dibromoacetic acid, dichloroacetic acid, monobromoacetic acid, monochloroacetic acid, tribromoacetic acid, and trichloroacetic acid. They are extracted, methylated, and then analyzed using a gas chromatograph equipped with an electron capture detector. Method validation experiments were performed to determine the method accuracy, precision, and detection limit for each of the compounds. Method detection limits for these nine haloacetic acids ranged from 0.11 to 0.45 microgram per liter. Quality-control practices include the use of blanks, quality-control samples, calibration verification standards, surrogate recovery, internal standard, matrix spikes, and duplicates.

  11. A laboratory rainfall simulator to study the soil erosion and runoff water

    NASA Astrophysics Data System (ADS)

    Cancelo González, Javier; Rial, M. E.; Díaz-Fierros, Francisco

    2010-05-01

    The soil erosion and the runoff water composition in some areas affected by forest fires or submitted to intensive agriculture are an important factor to keep an account, particularly in sensitive areas like estuary and rias that have a high importance in the socioeconomic development of some regions. An understanding of runoff production indicates the processes by which pollutants reach streams and also indicates the management techniques that might be uses to minimize the discharge of these materials into surface waters. One of the most methodology implemented in the soil erosion studies is a rainfall simulation. This method can reproduce the natural soil degradation processes in field or laboratory experiences. With the aim of improve the rainfall-runoff generation, a laboratory rainfall simulator which incorporates a fan-like intermittent water jet system for rainfall generation were modified. The major change made to the rainfall simulator consist in a system to coupling stainless steel boxes, whose dimensions are 12 x 20 x 45 centimeters, and it allows to place soil samples under the rainfall simulator. Previously these boxes were used to take soil samples in field with more of 20 centimeters of depth, causing the minimum disturbance in their properties and structure. These new implementations in the rainfall simulator also allow collect water samples of runoff in two ways: firstly, the rain water that constituted the overland flow or direct runoff and besides the rain water seeps into the soil by the process of infiltration and contributed to the subsurface runoff. Among main the variables controlled in the rainfall simulations were the soil slope and the intensity and duration of rainfall. With the aim of test the prototype, six soil samples were collected in the same sampling point and subjected to rainfall simulations in laboratory with the same intensity and duration. Two samples will constitute the control test, and they were fully undisturbed, and four samples were subjected to controlled burnings with different fire severity: two samples burnt to 250°C and the other two samples burnt to 450°C. Preliminary laboratory data of soil erosion and surface and subsurface runoff were obtained. The water parameters analysed were: pH, electrical conductivity, temperature (in the moment of sampling) and suspended sediments, ammonium, nitrates, total nitrogen (Kjeldahl method), within 24 hours after sampling.

  12. Massive outbreak of viral gastroenteritis associated with consumption of municipal drinking water in a European capital city.

    PubMed

    Werber, D; Lausević, D; Mugosa, B; Vratnica, Z; Ivanović-Nikolić, L; Zizić, L; Alexandre-Bird, A; Fiore, L; Ruggeri, F M; Di Bartolo, I; Battistone, A; Gassilloud, B; Perelle, S; Nitzan Kaluski, D; Kivi, M; Andraghetti, R; Pollock, K G J

    2009-12-01

    On 24 August 2008, an outbreak alert regarding cases of acute gastroenteritis in Podgorica triggered investigations to guide control measures. From 23 August to 7 September, 1699 cases were reported in Podgorica (population 136 000) and we estimated the total size of the outbreak to be 10 000-15 000 corresponding to an attack rate of approximately 10%. We conducted an age- and neighbourhood-matched case-control study, microbiologically analysed faecal and municipal water samples and assessed the water distribution system. All cases (83/83) and 90% (80/90) [corrected] of controls drank unboiled chlorinated municipal water [matched odds ratio (mOR) 11.2, 95% confidence interval (CI), 1.6-infinity]. Consumption of bottled water was inversely associated with illness (mOR 0.3, 95% CI 0.1-0.8). Analyses of faecal samples identified six norovirus genotypes (21/38 samples) and occasionally other viruses. Multiple defects in the water distribution system were noted. These results suggest that the outbreak was caused by faecally contaminated municipal water. It is unusual to have such a large outbreak in a European city especially when the municipal water supply is chlorinated. Therefore, it is important to establish effective multiple-barrier water-treatment systems whenever possible, but even with an established chlorinated supply, sustained vigilance is central to public health.

  13. Changes in mouse gut bacterial community in response to different types of drinking water.

    PubMed

    Dias, Marcela F; Reis, Mariana P; Acurcio, Leonardo B; Carmo, Anderson O; Diamantino, Cristiane F; Motta, Amanda M; Kalapothakis, Evanguedes; Nicoli, Jacques R; Nascimento, Andréa M A

    2018-04-01

    Gut microbiota exerts a fundamental role on host physiology, and how extrinsic perturbations influence its composition has been increasingly examined. However, the effect of drinking water on gut microbiota is still poorly understood. In this study, we explored the response of mouse gut bacterial community (fecal and mucosa-adhered) to the ingestion of different types of drinking water. The experimental cohort was divided according to different water sources into four groups of mice that consumed autoclaved tap water (control group), water collected directly from a drinking water treatment plant, tap water, and commercial bottled mineral water. Differences among groups were observed, especially related to control group, which exhibited the smallest intra-group variation, and the largest distance from test groups on the last experimental day. Clinically important taxa, such as Acinetobacter and Staphylococcus, increased in feces of mice that drank tap water and in mucosa-adhered samples of animals from disinfected and tap water groups. Furthermore, statistical analyses showed that both time elapsed between samplings and water type significantly influenced the variation observed in the samples. Our results reveal that drinking water potentially affects gut microbiota composition. Additionally, the increase of typical drinking water clinically relevant and antibiotic resistance-associated bacteria in gut microbiota is a cause of concern. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGill U; Gostick, J. T.; Gunterman, H. P.

    2010-06-25

    X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.

  15. Environmental surveillance master sampling schedule

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisping, L.E.

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of themore » onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.« less

  16. Ground-Water Quality Data in the Southern Sacramento Valley, California, 2005 - Results from the California GAMA Program

    USGS Publications Warehouse

    Milby Dawson, Barbara J.; Bennett, George L.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 2,100 square-mile Southern Sacramento Valley study unit (SSACV) was investigated from March to June 2005 as part of the Statewide Basin Assessment Project of Ground-Water Ambient Monitoring and Assessment (GAMA) Program. This study was designed to provide a spatially unbiased assessment of raw ground-water quality within SSACV, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 83 wells in Placer, Sacramento, Solano, Sutter, and Yolo Counties. Sixty-seven of the wells were selected using a randomized grid-based method to provide statistical representation of the study area. Sixteen of the wells were sampled to evaluate changes in water chemistry along ground-water flow paths. Four additional samples were collected at one of the wells to evaluate water-quality changes with depth. The GAMA Statewide Basin Assessment project was developed in response to the Ground-Water Quality Monitoring Act of 2001 and is being conducted by the California State Water Resources Control Board (SWRCB) in collaboration with the U.S. Geological Survey (USGS) and the Lawrence Livermore National Laboratory (LLNL). The ground-water samples were analyzed for a large number of man-made organic constituents (volatile organic compounds [VOCs], pesticides and pesticide degradates, pharmaceutical compounds, and wastewater-indicator constituents), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, and carbon), and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, matrix spikes) were collected at ten percent of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control data resulted in censoring of less than 0.03 percent of the analyses of ground-water samples. This study did not evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Health Services (CADHS) (Maximum Contaminant Levels [MCLs], notification levels [NLs], or lifetime health advisories [HA-Ls]) and thresholds established for aesthetic concerns (Secondary Maximum Contaminant Levels [SMCLs]). All wells were sampled for organic constituents and selected general water quality parameters; subsets of wells were sampled for inorganic constituents, nutrients, and radioactive constituents. Volatile organic compounds were detected in 49 out of 83 wells sampled and pesticides were detected in 35 out of 82 wells; all detections were below health-based thresholds, with the exception of 1 detection of 1,2,3-trichloropropane above a NL. Of the 43 wells sampled for trace elements, 27 had no detections of a trace element above a health-based threshold and 16 had at least one detection above. Of the 18 trace elements with health-based thresholds, 3 (arsenic, barium, and boron) were detected at concentrations higher an MCL. Of the 43 wells sampled for nitrate, only 1 well had a detection above the MCL. Twenty wells were sampled for radioactive constituents; only 1 (radon-222) was measured at activiti

  17. 40 CFR 420.21 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control system that utilizes filters to remove iron-bearing particles (fines) from blast furnace or... level is 10 pg/L per EPA Method 1613B for water and wastewater samples. (d) The term pg/L means... pollution control system means an emission control system that utilizes water to clean process or furnace...

  18. 40 CFR 420.21 - Specialized definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... control system that utilizes filters to remove iron-bearing particles (fines) from blast furnace or... level is 10 pg/L per EPA Method 1613B for water and wastewater samples. (d) The term pg/L means... pollution control system means an emission control system that utilizes water to clean process or furnace...

  19. 40 CFR 420.21 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission control system that utilizes filters to remove iron-bearing particles (fines) from blast furnace...-tetrachlorodibenzofuran, the minimum level is 10 pg/L per EPA Method 1613B for water and wastewater samples. (d) The term... term wet air pollution control system means an emission control system that utilizes water to clean...

  20. 40 CFR 420.21 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control system that utilizes filters to remove iron-bearing particles (fines) from blast furnace or... level is 10 pg/L per EPA Method 1613B for water and wastewater samples. (d) The term pg/L means... pollution control system means an emission control system that utilizes water to clean process or furnace...

  1. Groundwater-quality data from the eastern Snake River Plain Aquifer, Jerome and Gooding Counties, south-central Idaho, 2017

    USGS Publications Warehouse

    Skinner, Kenneth D.

    2018-05-11

    Groundwater-quality samples and water-level data were collected from 36 wells in the Jerome/Gooding County area of the eastern Snake River Plain aquifer during June 2017. The wells included 30 wells sampled for the U.S. Geological Survey’s National Water-Quality Assessment project, plus an additional 6 wells were selected to increase spatial distribution. The data provide water managers with the ability for an improved understanding of groundwater quality and flow directions in the area. Groundwater-quality samples were analyzed for nutrients, major ions, trace elements, and stable isotopes of water. Quality-assurance and quality-control measures consisted of multiple blank samples and a sequential replicate sample. All data are available online at the USGS National Water Information System.

  2. Evaluation of two spike-and-recovery controls for assessment of extraction efficiency in microbial source tracking studies

    USGS Publications Warehouse

    Stoeckel, D.M.; Stelzer, E.A.; Dick, L.K.

    2009-01-01

    Quantitative PCR (qPCR), applied to complex environmental samples such as water, wastewater, and feces, is susceptible to methodological and sample related biases. In this study, we evaluated two exogenous DNA spike-and-recovery controls as proxies for recovery efficiency of Bacteroidales 16S rDNA gene sequences (AllBac and qHF183) that are used for microbial source tracking (MST) in river water. Two controls-(1) the plant pathogen Pantoea stewartii, carrying the chromosomal target gene cpsD, and (2) Escherichia coli, carrying the plasmid-borne target gene DsRed2-were added to raw water samples immediately prior to concentration and DNA extraction for qPCR. When applied to samples processed in replicate, recovery of each control was positively correlated with the observed concentration of each MST marker. Adjustment of MST marker concentrations according to recovery efficiency reduced variability in replicate analyses when consistent processing and extraction methodologies were applied. Although the effects of this procedure on accuracy could not be tested due to uncertainties in control DNA concentrations, the observed reduction in variability should improve the strength of statistical comparisons. These findings suggest that either of the tested spike-and-recovery controls can be useful to measure efficiency of extraction and recovery in routine laboratory processing. ?? 2009 Elsevier Ltd.

  3. [The origin and quality of water for human consumption: the health of the population residing in the Matanza-Riachuelo river basin area in Greater Buenos Aires].

    PubMed

    Monteverde, Malena; Cipponeri, Marcos; Angelaccio, Carlos; Gianuzzi, Leda

    2013-04-01

    The aim of this study is to analyze the origin and quality of water used for consumption in a sample of households in Matanza-Riachuelo river basin area in Greater Buenos Aires, Argentina. The results of drinking water by source indicated that 9% of water samples from the public water system, 45% of bottled water samples and 80% of well water samples were not safe for drinking due to excess content of coliforms, Escherichia coli or nitrates. Individuals living in households where well water is the main source of drinking water have a 55% higher chance of suffering a water-borne disease; in the cases of diarrheas, the probability is 87% higher and in the case of dermatitis, 160% higher. The water for human consumption in this region should be provided by centralized sources that assure control over the quality of the water.

  4. Browning control of fresh-cut lettuce by phytoncide treatment.

    PubMed

    Kim, Do-Hee; Kim, Han-Bit; Chung, Hun-Sik; Moon, Kwang-Deog

    2014-09-15

    Phytoncide essential oil derived from pine leaves was applied for the control of enzymatic browning of fresh-cut lettuce. Changes in the browning characteristics of cut lettuce treated with phytoncide in an water or ethanol solution (1%, v/v) at 10°C were investigated for 12days at 4°C. Other samples dipped in distilled water or 95% ethanol were used as the controls. The samples treated with phytoncide in an ethanol solution showed significantly higher L* values and lower a* values, ΔE values, browning index, phenolic compounds, and enzyme activities (PPO, POD, PAL) related to browning. The samples dipped in distilled water showed the opposite tendency. On the basis of changes in the browning characteristics, anti-browning effects of each treatment, phytoncide in an ethanol solution was the most effective treatment applied. These results suggest that phytoncide treatment could be used as an effective method for controlling enzymatic browning in fresh-cut lettuce. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Effects of herbicide usage on water quality of selected streams in Wyoming

    USGS Publications Warehouse

    Butler, David L.

    1980-01-01

    During 1977 and 1978 the Wyoming Department of Agriculture, in conjunction with county weed and pest control districts, conducted a noxious-weed-control program in Wyoming. The herbicides primarily used were picloram, 2,4-D, and dicamba. The U.S. Geological Survey, in cooperation with the Wyoming Department of Agriculture, sampled and analyzed water from selected streams for these herbicides plus silvex; 2,4,5-T; and 2,4-DP.This report contains data for samples collected during 1977 and 1978. The most commonly detected herbicides in water samples were 2,4-D with 41-percent nonzero values and picloram with 34.5-percent nonzero values. Herbicide occurrence in bottom-material samples was uncommon; dicamba was found with 9-percent nonzero values. The maximum herbicide concentration in water was 1.1 micrograms per liter of 2,4-D, and the maximum herbicide concentration in bottom material was 8.0 micrograms per kilogram of 2,4-D. Based on available toxicity data and water-quality criteria, these herbicide concentrations do not constitute dangerous or harmful concentrations to humans or to the environment.

  6. The occurrence and dominant controls on arsenic in the Newark and Gettysburg Basins.

    PubMed

    Blake, Johanna M; Peters, Stephen C

    2015-02-01

    Elevated arsenic (As) concentrations in groundwater and rocks have been found in crystalline and sedimentary aquifers from New England to Pennsylvania, USA. The arsenic geochemistry and water-rock interactions of the Northern Appalachian Mountains and the Newark Basin have been researched at length, however, little is known about arsenic in the Gettysburg Basin. Both the Newark and Gettysburg Basins were formed during the breakup of Pangea, sediment deposition occurred during the Triassic and lithologies are of similar depositional environment. We compile and review the work done in the Newark Basin and collect new samples in the Gettysburg Basin for comparison. The Gettysburg Basin has 18%-39% of rock samples with arsenic concentrations greater than the crustal average of 2 mg/kg, while the Newark Basin has 73% to 95% of rock samples above the crustal average. The strongest controls on arsenic in rocks of the Gettysburg Basin are the relationship between arsenic and iron and silicon concentrations while the strongest controls in the Newark Basin are the relationship between arsenic and iron and organic carbon concentrations. The groundwater arsenic concentrations follow similarly with 8-39% of water samples from the Gettysburg Basin above 10 μg/L and 24-54% of water samples from the Newark Basin above 10 μg/L. The strongest controls on arsenic in water of the Gettysburg Basin are pH, alkalinity and silicon, while the strongest controls in the Newark Basin are pH and alkalinity. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Evaluation of Surface Quality of Silicone Impression Materials after Disinfection with Ozone Water: An In vitro Study.

    PubMed

    Abinaya, K; Muthu Kumar, B; Ahila, S C

    2018-01-01

    To compare and evaluate the surface quality of silicone impression materials after ozone water disinfection. A total of 60 samples were prepared on a stainless steel die (American Dental Association specification no. 19 and International Standard of Organization - 4823). The samples were divided into four groups; each group contains 15 samples. Group A as control, Group B, C, and D disinfected with 2% glutaraldehyde, 5.25% sodium hypochlorite, and ozone water, respectively. The samples were made according to the manufacturer's instructions, and the samples were allowed to set in a thermostatically controlled water bath at 35°C ± 1°C and retrieved after 10 min. The surface qualities of the samples were measured in stereomicroscope with ×20 magnification. The data obtained were analyzed using Chi-square test, and the " P " value was calculated. The results showed that there were no differences in the surface quality among the Groups A, C, and D for addition silicone putty and light body and medium body impression materials than the Group B. This study concluded that ozone water disinfection showed least changes when compared to 5.25%sodium hypochloride and 2% glutaraldehyde disinfection for addition silicone putty , light body and medium body impression materials.

  8. Field-based evaluation of a male-specific (F+) RNA coliphage ...

    EPA Pesticide Factsheets

    Fecal contamination of water poses a significant risk to public health due to the potential presence of pathogens, including enteric viruses. Thus, sensitive, reliable and easy to use methods for the detection of microorganisms are needed to evaluate water quality. In this study, we performed a field evaluation of an anion-exchange resin based platform to concentrate F-RNA coliphages (fecal/enteric virus indicators) from diverse fecally impacted environmental waters. In this platform, F-RNA coliphages are adsorbed to anion-exchange resin and direct nucleic acid isolation is performed, yielding a sample amenable to real-time reverse transcriptase PCR detection. Matrix-dependent inhibition was evaluated using known quantities of spiked F-RNA coliphage genogroups GI, GII, GII and GIV. Detection was successful in 97%, 72%, 85% and 98% of the samples for spiked F-RNA coliphage GI, GII, GIII and GIV, respectively, and was differentially affected by inhibitory properties specific to each water sample. No association between inhibition and the water samples’ physicochemical properties was apparent. Parallel evaluations of the spiked samples with internal amplification control (IAC) reactions (a widely used control to assess inhibition) demonstrated that IAC reaction inhibition was not agreement with that observed for spiked samples, suggesting that testing of spiked samples allows for better assessments of matrix-dependent inhibition. Additionally, the anion-

  9. High-throughput immunomagnetic scavenging technique for quantitative analysis of live VX nerve agent in water, hamburger, and soil matrixes.

    PubMed

    Knaack, Jennifer S; Zhou, Yingtao; Abney, Carter W; Prezioso, Samantha M; Magnuson, Matthew; Evans, Ronald; Jakubowski, Edward M; Hardy, Katelyn; Johnson, Rudolph C

    2012-11-20

    We have developed a novel immunomagnetic scavenging technique for extracting cholinesterase inhibitors from aqueous matrixes using biological targeting and antibody-based extraction. The technique was characterized using the organophosphorus nerve agent VX. The limit of detection for VX in high-performance liquid chromatography (HPLC)-grade water, defined as the lowest calibrator concentration, was 25 pg/mL in a small, 500 μL sample. The method was characterized over the course of 22 sample sets containing calibrators, blanks, and quality control samples. Method precision, expressed as the mean relative standard deviation, was less than 9.2% for all calibrators. Quality control sample accuracy was 102% and 100% of the mean for VX spiked into HPLC-grade water at concentrations of 2.0 and 0.25 ng/mL, respectively. This method successfully was applied to aqueous extracts from soil, hamburger, and finished tap water spiked with VX. Recovery was 65%, 81%, and 100% from these matrixes, respectively. Biologically based extractions of organophosphorus compounds represent a new technique for sample extraction that provides an increase in extraction specificity and sensitivity.

  10. Lead and Copper Control 101

    EPA Science Inventory

    This presentation is an overview of the most important water treatment strategies for the control of lead and copper release from drinking water corrosion. In addition to the sections specifically on lead and copper treatment, sections are included that cover sampling to find le...

  11. Ground- and Surface-Water Chemistry of Handcart Gulch, Park County, Colorado, 2003-2006

    USGS Publications Warehouse

    Verplanck, Philip L.; Manning, Andrew H.; Kimball, Briant A.; McCleskey, R. Blaine; Runkel, Robert L.; Caine, Jonathan S.; Adams, Monique; Gemery-Hill, Pamela A.; Fey, David L.

    2008-01-01

    As part of a multidisciplinary project to determine the processes that control ground-water chemistry and flow in mineralized alpine environments, ground- and surface-water samples from Handcart Gulch, Colorado were collected for analysis of inorganic solutes and water and dissolved sulfate stable isotopes in selected samples. The primary aim of this study was to document variations in ground-water chemistry in Handcart Gulch and to identify changes in water chemistry along the receiving stream of Handcart Gulch. Water analyses are reported for ground-water samples collected from 12 wells in Handcart Gulch, Colorado. Samples were collected between August 2003 and October 2005. Water analyses for surface-water samples are reported for 50 samples collected from Handcart Gulch and its inflows during a low-flow tracer injection on August 6, 2003. In addition, water analyses are reported for three other Handcart Gulch stream samples collected in September 2005 and March 2006. Reported analyses include field parameters (pH, specific conductance, temperature, dissolved oxygen, and Eh), major and trace constituents, oxygen and hydrogen isotopic composition of water and oxygen and sulfur isotopic composition of dissolved sulfate. Ground-water samples from this study are Ca-SO4 type and range in pH from 2.5 to 6.8. Most of the samples (75 percent) have pH values between 3.3 and 4.3. Surface water samples are also Ca-SO4 type and have a narrower range in pH (2.7?4.0). Ground- and surface-water samples vary from relatively dilute (specific conductance of 68 ?S/cm) to concentrated (specific conductance of 2,000 ?S/cm).

  12. 2004 National Atrazine Occurrence Monitoring Program using the Abraxis ELISA method.

    PubMed

    Graziano, Nicole; McGuire, Michael J; Roberson, Alan; Adams, Craig; Jiang, Hua; Blute, Nicole

    2006-02-15

    The goal of this project was to gain a better understanding of atrazine occurrence in the United States by surveying drinking water utilities' sources and finished water for atrazine on a weekly basis for seven months. Atrazine is a contaminant of interest because the United States Environmental Protection Agency (USEPA) has found short-term atrazine exposure above the drinking water maximum contaminant level (MCL) to potentially cause heart, lung, and kidney congestion, low blood pressure, muscle spasms, weight loss, and damage to the adrenal glands. Long-term exposure to atrazine concentrations above the drinking water MCL has been linked to weight loss, cardiovascular damage, retinal and muscle degeneration, and cancer. This survey effort improved upon previously conducted atrazine surveys through intensive, high frequency sampling (participating plants sampled their raw and finished water on a weekly basis for approximately seven months). Such an intensive effort allowed the authors to gain a better understanding of short-term atrazine occurrence and its variability in drinking water sources. This information can benefit the drinking water industry by facilitating (1) better atrazine occurrence management (i.e., awareness when plants may be more susceptible to atrazine), (2) more efficient atrazine control (e.g., effective treatment alternatives and more effective response to atrazine occurrence), and (3) treatment cost reduction (e.g., efficient atrazine control can result in substantial cost savings). Forty-seven drinking watertreatment plants located primarily in the Midwestern United States participated in the survey and sampled their raw and finished water on a weekly basis from March through October. Samples were analyzed using the Abraxis enzyme-linked immunosorbent assay (ELISA) test kit. Confirmation samples for quality assurance/quality control (QA/QC) purposes were analyzed using solid-phase extraction (SPE) followed by gas chromatography mass spectrophotometry (GC/MS). Several important conclusions can be drawn from this study including (1) surface waters were confirmed to be more vulnerable to atrazine contamination than groundwater sources, (2) peak atrazine concentrations corresponded well to precipitation/runoff events, and (3) atrazine occurrence tended to be uniform geographically when compared by river drainage basins. In addition, this project confirmed that the Abraxis atrazine ELISA test kit tended to have a positive bias (i.e., the measured ELISA concentration was higher than the actual concentration) in most measured samples. Finished samples tended to have more of a positive bias than raw water samples. Therefore, this bias may limit the effectiveness for ELISA for regulatory monitoring. There are many other applications for ELISA, however, including frequent monitoring for early detections of atrazine concentration changes that might trigger conventional analysis by GC/MS or be used for activated carbon dosing or other treatment operating controls.

  13. Protocol for collecting eDNA samples from streams [Version 2.3

    Treesearch

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  14. Interaction of gases with lunar materials. [analysis of lunar samples from Apollo 17 flight

    NASA Technical Reports Server (NTRS)

    Holmes, H. F.; Fuller, E. L., Jr.; Gammage, R. B.

    1974-01-01

    The surface chemistry of Apollo 17 lunar fines samples 74220 (the orange soil) and 74241 (the gray control soil) has been studied by measuring the adsorption of nitrogen, argon, and oxygen (all at 77 K) and also water vapor (at 20 or 22 C). In agreement with results for samples from other missions, both samples had low initial specific surface areas, consisted of nonporous particles, and were attacked by water vapor at high relative pressure to give an increased specific surface area and create a pore system which gave rise to a capillary condensation hysteresis loop in the adsorption isotherms. In contrast to previous samples, both of the Apollo 17 soils were partially hydrophobic in their initial interaction with water vapor (both samples were completely hydrophilic after the reaction with water). The results are consistent with formation at high temperatures without subsequent exposure to significant amounts of water.

  15. Ground-Water Quality Data in the San Fernando-San Gabriel Study Unit, 2005 - Results from the California GAMA Program

    USGS Publications Warehouse

    Land, Michael; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 460 square mile San Fernando-San Gabriel study unit (SFSG) was investigated between May and July 2005 as part of the Priority Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The San Fernando-San Gabriel study was designed to provide a spatially unbiased assessment of raw ground-water quality within SFSG, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 52 wells in Los Angeles County. Thirty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and seventeen wells were selected to aid in the evaluation of specific water-quality issues or changes in water chemistry along a historic ground-water flow path (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,2,3-trichloropropane (1,2,3-TCP), and 1,4-dioxane], naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, and carbon), and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, samples for matrix spikes) were collected at approximately one-fifth (11 of 52) of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control results showed that the data had very little bias or variability and resulted in censoring of less than 0.7 percent (32 of 4,484 measurements) of the data collected for ground-water samples. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs were detected in more than 90 percent (33 of 35) of grid wells. For all wells sampled for SFSG, nearly all VOC detections were below health-based thresholds, and most were less than one-tenth of the threshold values. Samples from seven wells had at least one detection of PCE, TCE, tetrachloromethane, NDMA, or 1,2,3-TCP at or above a health-based threshold. Pesticides were detected in about 90 percent (31 of 35) grid wells and all detections in samples from SFSG wells were below health-based thresholds. Major ions, trace elements, and nutrients in samples from 17 SFSG wells were all below health-based thresholds, with the exception of one detection of nitrate that was above the USEPA maximum contaminant level (MCL-US). With the exception of 14 samples having radon-222 above the proposed MCL-US, radioactive constituents were below health-based thresholds for 16 of the SFSG wells sampled. Total dissolved solids in 6 of the 24 SFSG wells that were sampled ha

  16. Measuring Water Quality in Hong Kong using an Underwater Remotely Operated Vehicle

    NASA Astrophysics Data System (ADS)

    Evans, J. W.

    2017-12-01

    Clean water is a vital necessity in our day to day lives, with all living organisms depending on it for survival and countless others relying on it as their habitat. The waters surrounding Hong Kong are home to a wide diversity of marine animals and organisms but are polluted for a variety of reasons. This pollution includes marine debris, industrial and construction waste, a high concentration of organic material, and other pollutants. This research project will focus on collecting water and soil samples from various locations around the Hong Kong ocean waters for analytical chemical sampling. A Remote Operated Vehicle (ROV) will be designed, built and used for collecting the water and soil samples. ROVs are used around the world in oceans and other deep water applications. ThisROV will be tethered with a control system and equipped with a camera, mechanical arms for collections water and soil samples and sensors for testing basic water parameters. Using a ROV will allow for long term sampling in the same location to occur as required. The collected samples will be tested in the lab to determine overall water and soil quality, allowing conclusions to be drawn about the conditions of the tested area.

  17. 33 CFR 159.317 - Sampling and reporting.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) POLLUTION MARINE SANITATION DEVICES Discharge of Effluents in Certain Alaskan Waters by Cruise Vessel... cruise vessel that discharges treated sewage and/or graywater in the applicable waters of Alaska shall.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...

  18. 33 CFR 159.317 - Sampling and reporting.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) POLLUTION MARINE SANITATION DEVICES Discharge of Effluents in Certain Alaskan Waters by Cruise Vessel... cruise vessel that discharges treated sewage and/or graywater in the applicable waters of Alaska shall.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...

  19. 33 CFR 159.317 - Sampling and reporting.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) POLLUTION MARINE SANITATION DEVICES Discharge of Effluents in Certain Alaskan Waters by Cruise Vessel... cruise vessel that discharges treated sewage and/or graywater in the applicable waters of Alaska shall.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...

  20. 40 CFR 265.92 - Sampling and analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Analytical procedures; and (4) Chain of custody control. [Comment: See “Procedures Manual For Ground-water... characterizing the suitability of the ground water as a drinking water supply, as specified in appendix III. (2...

  1. 40 CFR 265.92 - Sampling and analysis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Analytical procedures; and (4) Chain of custody control. [Comment: See “Procedures Manual For Ground-water... characterizing the suitability of the ground water as a drinking water supply, as specified in appendix III. (2...

  2. 40 CFR 265.92 - Sampling and analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Analytical procedures; and (4) Chain of custody control. [Comment: See “Procedures Manual For Ground-water... characterizing the suitability of the ground water as a drinking water supply, as specified in appendix III. (2...

  3. Ground-Water Quality Data in the Coachella Valley Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Goldrath, Dara A.; Wright, Michael T.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 820 square-mile Coachella Valley Study Unit (COA) was investigated during February and March 2007 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground water used for public-water supplies within the Coachella Valley, and to facilitate statistically consistent comparisons of ground-water quality throughout California. Samples were collected from 35 wells in Riverside County. Nineteen of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Sixteen additional wells were sampled to evaluate changes in water chemistry along selected ground-water flow paths, examine land use effects on ground-water quality, and to collect water-quality data in areas where little exists. These wells were referred to as 'understanding wells'. The ground-water samples were analyzed for a large number of organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (uranium, tritium, carbon-14, and stable isotopes of hydrogen, oxygen, and boron), and dissolved noble gases (the last in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled ground water. A quality-control sample (blank, replicate, or matrix spike) was collected at approximately one quarter of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information resulted in V-coding less than 0.1 percent of the data collected. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is supplied to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and thresholds established for aesthetic purposes (secondary maximum contaminant levels, SMCL-CA) by CDPH. Most constituents detected in ground-water samples were at concentrations below drinking-water thresholds. Volatile organic compounds, pesticides, and pesticide degradates were detected in less than one-third of the grid well samples collected. All VOC and pesticide concentrations measured were below health-based thresholds. Potential waste-water indicators were detected in less than half of the wells sampled, and no detections were above health-based thresholds. Perchlorate was detected in seven grid wells; concentrations from two wells were above the CDPH maximum contaminant level (MCL-CA). Most detections of trace elements in samples collected from COA Study Unit wells were below water-quality thresholds. Exceptions include five samples of arsenic that were above the USEPA maximum contaminant level (MCL-US), two detections of boron above the CDPH notification level (NL-CA), and two detections of mol

  4. An institutional outbreak of leptospirosis in Chennai, South India.

    PubMed

    Ramakrishnan, R; Patel, M S; Gupte, M D; Manickam, P; Venkataraghavan, S

    2003-03-01

    The emergence of an outbreak of leptospirosis in a nurses' hostel in Chennai presented a challenge to identify and control the source of the outbreak. Sixty-nine residents and staff members were interviewed to assess exposure factors. Blood samples from the acute and convalescent patients were tested with the Microscopic Agglutination Test using the serovars prevalent in Chennai. Polymerase Chain Reaction (PCR) was conducted on serum and water samples. Based on preliminary investigation, control measures with standard hygienic measures were instituted. The attack rate was 35%. The epidemic curve suggested continuous or intermittent exposure to infection over a five-week period. Twenty residents (three asymptomatic) developed laboratory confirmed Leptospira icterohemorrhagiae. Residents collected water from an underground storage tank that was filled twice weekly from a mobile water tanker with a bucket on a rope, and the tank was usually left open. PCR tests confirmed the presence of leptospires from this water. Other control measures included cleaning the large backyard with its many stray dogs and rats, chlorinating water supplies, boiling drinking water and health education. No further cases occurred twelve days after implementing control measures. Access to clean water, not only for drinking but also for bathing, brushing and washing is essential to prevent water-borne outbreaks.

  5. Lead and Copper Control 101-slides

    EPA Science Inventory

    This presentation is an overview of the most important water treatment strategies for the control of lead and copper release from drinking water corrosion. In addition to the sections specifically on lead and copper treatment, sections are included that cover sampling to find le...

  6. Groundwater quality data from the National Water-Quality Assessment Project, May 2012 through December 2013

    USGS Publications Warehouse

    Arnold, Terri L.; Desimone, Leslie A.; Bexfield, Laura M.; Lindsey, Bruce D.; Barlow, Jeannie R.; Kulongoski, Justin T.; Musgrove, MaryLynn; Kingsbury, James A.; Belitz, Kenneth

    2016-06-20

    Groundwater-quality data were collected from 748 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from May 2012 through December 2013. The data were collected from four types of well networks: principal aquifer study networks, which assess the quality of groundwater used for public water supply; land-use study networks, which assess land-use effects on shallow groundwater quality; major aquifer study networks, which assess the quality of groundwater used for domestic supply; and enhanced trends networks, which evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, and radionuclides. These groundwater quality data are tabulated in this report. Quality-control samples also were collected; data from blank and replicate quality-control samples are included in this report.

  7. Laser Initiated Ignition of Liquid Propellant

    DTIC Science & Technology

    1991-01-31

    containers held in a water bath of constant temperature 70*C. A larger vessel containing approximately 2ml of propellant was also heated in each experiment and...controller. A stirrer and forced water circulation ensured that all samples were kept at the same temperature. The water wai first heated to the final 5... electrolysed samples. 3 .. .. ....... ......................... volume of 10 ....... . 5 ....... I • . ... .. . .... .. ...... .. . . .. . . ... . .61.8 2 22i

  8. Decontamination of an Extracorporeal Membrane Oxygenator Contaminated With Mycobacterium chimaera.

    PubMed

    Garvey, Mark I; Phillips, Natalie; Bradley, Craig W; Holden, Elisabeth

    2017-10-01

    Water samples taken from extracorporeal membrane oxygenator (ECMO) devices used at University Hospitals Birmingham yielded high total viable counts (TVCs) containing a variety of microorganisms, including M. chimaera. Disinfection resulted in the reduction of TVCs and eradication of Mycobacterium chimaera. Weekly disinfection and water sampling are required to manage the water quality in these devices. Infect Control Hosp Epidemiol 2017;38:1244-1246.

  9. Comparative assessment of the bacterial communities associated with Aedes aegypti larvae and water from domestic water storage containers.

    PubMed

    Dada, Nsa; Jumas-Bilak, Estelle; Manguin, Sylvie; Seidu, Razak; Stenström, Thor-Axel; Overgaard, Hans J

    2014-08-24

    Domestic water storage containers constitute major Aedes aegypti breeding sites. We present for the first time a comparative analysis of the bacterial communities associated with Ae. aegypti larvae and water from domestic water containers. The 16S rRNA-temporal temperature gradient gel electrophoresis (TTGE) was used to identify and compare bacterial communities in fourth-instar Ae. aegypti larvae and water from larvae positive and negative domestic containers in a rural village in northeastern Thailand. Water samples were cultured for enteric bacteria in addition to TTGE. Sequences obtained from TTGE and bacterial cultures were clustered into operational taxonomic units (OTUs) for analyses. Significantly lower OTU abundance was found in fourth-instar Ae. aegypti larvae compared to mosquito positive water samples. There was no significant difference in OTU abundance between larvae and mosquito negative water samples or between mosquito positive and negative water samples. Larval samples had significantly different OTU diversity compared to mosquito positive and negative water samples, with no significant difference between mosquito positive and negative water samples. The TTGE identified 24 bacterial taxa, belonging to the phyla Proteobacteria, Firmicutes, Actinobacteria, Bacteroidetes and TM7 (candidate phylum). Seven of these taxa were identified in larval samples, 16 in mosquito positive and 13 in mosquito negative water samples. Only two taxa, belonging to the phyla Firmicutes and Actinobacteria, were common to both larvae and water samples. Bacilli was the most abundant bacterial class identified from Ae. aegypti larvae, Gammaproteobacteria from mosquito positive water samples, and Flavobacteria from mosquito negative water samples. Enteric bacteria belonging to the class Gammaproteobacteria were sparsely represented in TTGE, but were isolated from both mosquito positive and negative water samples by selective culture. Few bacteria from water samples were identified in fourth-instar Ae. aegypti larvae, suggesting that established larval bacteria, most likely acquired at earlier stages of development, control the larval microbiota. Further studies at all larval stages are needed to fully understand the dynamics involved. Isolation of enteric bacteria from water samples supports earlier outcomes of E. coli contamination in Ae. aegypti infested domestic containers, suggesting the need to further explore the role of enteric bacteria in Ae. aegypti infestation.

  10. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKES

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 49 field control samples (spikes). Measurements were made for up to 11 metals in samples of water, blood, and urine. Field controls were used to assess recovery of target analytes from a sample media during s...

  11. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  12. A Randomized Controlled Trial to Assess the Impact of Ceramic Water Filters on Prevention of Diarrhea and Cryptosporidiosis in Infants and Young Children-Western Kenya, 2013.

    PubMed

    Morris, Jamae Fontain; Murphy, Jennifer; Fagerli, Kirsten; Schneeberger, Chandra; Jaron, Peter; Moke, Fenny; Juma, Jane; Ochieng, J Ben; Omore, Richard; Roellig, Dawn; Xiao, Lihua; Priest, Jeffrey W; Narayanan, Jothikumar; Montgomery, Joel; Hill, Vince; Mintz, Eric; Ayers, Tracy L; O'Reilly, Ciara E

    2018-04-02

    Cryptosporidium is a leading cause of diarrhea among Kenyan infants. Ceramic water filters (CWFs) are used for household water treatment. We assessed the impact of CWFs on diarrhea, cryptosporidiosis prevention, and water quality in rural western Kenya. A randomized, controlled intervention trial was conducted in 240 households with infants 4-10 months old. Twenty-six weekly household surveys assessed infant diarrhea and health facility visits. Stool specimens from infants with diarrhea were examined for Cryptosporidium . Source water, filtered water, and filter retentate were tested for Cryptosporidium and/or microbial indicators. To estimate the effect of CWFs on health outcomes, logistic regression models using generalized estimating equations were performed; odds ratios (ORs) and 95% confidence intervals (CIs) are reported. Households reported using surface water (36%), public taps (29%), or rainwater (17%) as their primary drinking water sources, with no differences in treatment groups. Intervention households reported less diarrhea (7.6% versus 8.9%; OR: 0.86 [0.64-1.16]) and significantly fewer health facility visits for diarrhea (1.0% versus 1.9%; OR: 0.50 [0.30-0.83]). In total, 15% of intervention and 12% of control stools yielded Cryptosporidium ( P = 0.26). Escherichia coli was detected in 93% of source water samples; 71% of filtered water samples met World Health Organization recommendations of < 1 E. coli /100 mL. Cryptosporidium was not detected in source water and was detected in just 2% of filter rinses following passage of large volumes of source water. Water quality was improved among CWF users; however, the short study duration and small sample size limited our ability to observe reductions in cryptosporidiosis.

  13. Ground-Water Quality Data in the Kern County Subbasin Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Pimentel, Isabel; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 3,000 square-mile Kern County Subbasin study unit (KERN) was investigated from January to March, 2006, as part of the Priority Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the California State Water Resources Control Board (SWRCB) in collaboration with the U.S. Geological Survey (USGS) and the Lawrence Livermore National Laboratory (LLNL). The Kern County Subbasin study was designed to provide a spatially unbiased assessment of raw (untreated) ground-water quality within KERN, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 50 wells within the San Joaquin Valley portion of Kern County. Forty-seven of the wells were selected using a randomized grid-based method to provide a statistical representation of the ground-water resources within the study unit. Three additional wells were sampled to aid in the evaluation of changes in water chemistry along regional ground-water flow paths. The ground-water samples were analyzed for a large number of man-made organic constituents (volatile organic compounds [VOCs], pesticides, and pesticide degradates), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon) and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, and laboratory matrix spikes) were collected and analyzed at approximately 10 percent of the wells, and the results for these samples were used to evaluate the quality of the data from the ground-water samples. Assessment of the quality-control information resulted in censoring of less than 0.4 percent of the data collected for ground-water samples. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw ground water typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply, not to the raw ground water, but to treated water that is served to the consumer. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and as well as with thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs and pesticides each were detected in approximately 60 percent of the grid wells, and detections of all compounds but one were below health-based thresholds. The fumigant, 1,2-dibromo-3-chloropropane (DBCP), was detected above the USEPA maximum contaminant level (MCL-US) in one sample. Detections of most inorganic constituents were also below health-based thresholds. Constituents detected above health-based thresholds include: nitrate, (MCL-US, 2 samples), arsenic (MCL-US, 2 samples), and vanadium (California notification level, NL-CA, 1 sample). All detections of radioactive constituents were below health-based thresholds, although nine samples had activities of radon-222 above the lower proposed MCL-US. Most of the samples from KERN wells had concentrations of major elements, total dissolved solids, and trace elements below the non-enforceable thresholds set for aesthetic concerns.

  14. Critical control points for foods prepared in households whose members had either alleged typhoid fever or diarrhea.

    PubMed

    Michanie, S; Bryan, F L; Alvarez, P; Olivo, A B; Paniagua, A

    1988-10-01

    Hazard analysis of food preparation practices were conducted in four households and eleven others were visited to survey both food preparation practices and environmental conditions. Households selected had members who were suffering from either diarrhea of unknown etiology or alleged typhoid fever. Hazard analyses and sanitary surveys included gathering data on time-temperature exposures of foods, collecting samples of food and drinking water, sampling sewage or drains, and obtaining stool specimens from persons with diarrhea and from family controls. Food samples were tested for aerobic mesophilic colony counts and common foodborne pathogens; specimens were tested for Salmonella, Shigella, Campylobacter and Yersinia. Campylobacter was isolated from two persons purported to have diarrhea, but neither Salmonella, Shigella nor Yersinia were recovered from alleged cases or controls. Salmonella agona was recovered from a latrine. Most foods were cooked to internal temperatures to or near to boiling. Those not promptly eaten were held at ambient room or outside temperatures until a subsequent meal, until a family member returned home, or until lunch time when taken to the fields. During these intervals, microorganisms multiplied and mesophilic aerobic organisms increased often reaching 10(8)/g or greater before consumption. None of these foods were reheated before eating. Bacillus cereus was isolated from 4 of 10 samples; one sample of 'moro' (beans and rice) exceeded 10(6)/g, two other samples exceeded 10(3)/g. Staphylococcus aureus was isolated from 7 of 14 samples, one exceeded 10(5)/g. Fecal coliforms were isolated from 8 of 14 food samples, five exceeded 10(5)/g. Neither Salmonella nor Shigella were isolated from any food, the community water supplies or from vessels of water within houses. Fecal coliform counts of water were less than 3/ml, except one sample from a clay vessel (9/ml). Risks associated with cooked foods which were not promptly eaten appeared to be greater than that associated with water.

  15. Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water.

    PubMed

    Fykse, Else M; Nilsen, Trine; Nielsen, Agnete Dessen; Tryland, Ingun; Delacroix, Stephanie; Blatny, Janet M

    2012-02-01

    Transport of ballast water is one major factor in the transmission of aquatic organisms, including pathogenic bacteria. The IMO-guidelines of the Convention for the Control and Management of Ships' Ballast Water and Sediments, states that ships are to discharge <1 CFU per 100 ml ballast water of toxigenic Vibrio cholerae, emphasizing the need to establish test methods. To our knowledge, there are no methods sensitive and rapid enough available for cholera surveillance of ballast water. In this study real-time PCR and NASBA methods have been evaluated to specifically detect 1 CFU/100ml of V. cholerae in ballast water. Ballast water samples spiked with V. cholerae cells were filtered and enriched in alkaline peptone water before PCR or NASBA detection. The entire method, including sample preparation and analysis was performed within 7 h, and has the potential to be used for analysis of ballast water for inspection and enforcement control. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Quality-Assurance/Quality-Control Manual for Collection and Analysis of Water-Quality Data in the Ohio District, US Geological Survey

    USGS Publications Warehouse

    Francy, D.S.; Jones, A.L.; Myers, Donna N.; Rowe, G.L.; Eberle, Michael; Sarver, K.M.

    1998-01-01

    The U.S. Geological Survey (USGS), Water Resources Division (WRD), requires that quality-assurance/quality-control (QA/QC) activities be included in any sampling and analysis program. Operational QA/QC procedures address local needs while incorporating national policies. Therefore, specific technical policies were established for all activities associated with water-quality project being done by the Ohio District. The policies described in this report provide Ohio District personnel, cooperating agencies, and others with a reference manual on QA/QC procedures that are followed in collecitng and analyzing water-quality samples and reporting water-quality information in the Ohio District. The project chief, project support staff, District Water-Quality Specialist, and District Laboratory Coordinator are all involved in planning and implementing QA/QC activities at the district level. The District Chief and other district-level managers provide oversight, and the Regional Water-Quality Specialist, Office of Water Quality (USGS headquarters), and the Branch of Quality Systems within the Office of Water Quality create national QA/QC polices and provide assistance to District personnel. In the literature, the quality of all measurement data is expressed in terms of precision, variability, bias, accuracy, completeness, representativeness, and comparability. In the Ohio District, bias and variability will be used to describe quality-control data generated from samples in the field and laboratory. Each project chief must plan for implementation and financing of QA/QC activities necessary to achieve data-quality objectives. At least 15 percent of the total project effort must be directed toward QA/QC activities. Of this total, 5-10 percent will be used for collection and analysis of quality-control samples. This is an absolute minimum, and more may be required based on project objectives. Proper techniques must be followed in the collection and processing of surface-water, ground-water, biological, precipitation, bed-sediment, bedload, suspended-sediment, and solid-phase samples. These techniques are briefly described in this report and are extensively documented. The reference documents listed in this report will be kept by the District librarian and District Water-Quality Specialist and updated regularly so that they are available to all District staff. Proper handling and documentation before, during, and after field activities are essential to ensure the integrity of the sample and to correct erroneous reporting of data results. Field sites are to be properly identified and entered into the data base before field data-collection activities begin. During field activities, field notes are to be completed and sample bottles appropriately labeled a nd stored. After field activities, all paperwork is to be completed promptly and samples transferred to the laboratory within allowable holding times. All equipment used by District personnel for the collection and processing of water-quality samples is to be properly operated, maintained, and calibrated by project personnel. This includes equipment for onsite measurement of water-quality characteristics (temperature, specific conductance, pH, dissolved oxygen, alkalinity, acidity, and turbidity) and equipment and instruments used for biological sampling. The District Water-Quality Specialist and District Laboratory Coordinator are responsible for preventive maintenance and calibration of equipment in the Ohio District laboratory. The USGS National Water Quality Laboratory in Arvada, Colo., is the primary source of analytical services for most project work done by the Ohio District. Analyses done at the Ohio District laboratory are usually those that must be completed within a few hours of sample collection. Contract laboratories or other USGS laboratories are sometimes used instead of the NWQL or the Ohio District laboratory. When a contract laboratory is used, the projec

  17. Presumptive Sources of Fecal Contamination in Four Tributaries to the New River Gorge National River, West Virginia, 2004

    USGS Publications Warehouse

    Mathes, Melvin V.; O'Brien, Tara L.; Strickler, Kriston M.; Hardy, Joshua J.; Schill, William B.; Lukasik, Jerzy; Scott, Troy M.; Bailey, David E.; Fenger, Terry L.

    2007-01-01

    Several methods were used to determine the sources of fecal contamination in water samples collected during September and October 2004 from four tributaries to the New River Gorge National River -- Arbuckle Creek, Dunloup Creek, Keeney Creek, and Wolf Creek. All four tributaries historically have had elevated levels of fecal coliform bacteria. The source-tracking methods used yielded various results, possibly because one or more methods failed. Sourcing methods used in this study included the detection of several human-specific and animal-specific biological or molecular markers, and library-dependent pulsed-field gel electrophoresis analysis that attempted to associate Escherichia coli bacteria obtained from water samples with animal sources by matching DNA-fragment banding patterns. Evaluation of the results of quality-control analysis indicated that pulsed-field gel electrophoresis analysis was unable to identify known-source bacteria isolates. Increasing the size of the known-source library did not improve the results for quality-control samples. A number of emerging methods, using markers in Enterococcus, human urine, Bacteroidetes, and host mitochondrial DNA, demonstrated some potential in associating fecal contamination with human or animal sources in a limited analysis of quality-control samples. All four of the human-specific markers were detected in water samples from Keeney Creek, a watershed with no centralized municipal wastewater-treatment facilities, thus indicating human sources of fecal contamination. The human-specific Bacteroidetes and host mitochondrial DNA markers were detected in water samples from Dunloup Creek, Wolf Creek, and to a lesser degree Arbuckle Creek. Results of analysis for wastewater compounds indicate that the September 27 sample from Arbuckle Creek contained numerous human tracer compounds likely from sewage. Dog, horse, chicken, and pig host mitochondrial DNA were detected in some of the water samples with the exception of the October 5 sample from Dunloup Creek. Cow, white-tailed deer, and Canada goose DNA were not detected in any of the samples collected from the four tributaries, despite the presence of these animals in the watersheds. Future studies with more rigorous quality-control analyses are needed to investigate the potential applicability and use of these emerging methods. Because many of the detections for the various methods could vary over time and with flow conditions, repeated sampling during both base flow and storm events would be necessary to more definitively determine the sources of fecal contamination for each watershed.

  18. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York - July 2005 through June 2007

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2005 through June 2007. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: total aluminum, calcium, magnesium, nitrate (colorimetric method), potassium, silicon, sodium, and sulfate. Eight of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: total aluminum, calcium, dissolved organic carbon, chloride, nitrate (ion chromatograph), potassium, silicon, and sulfate. The magnesium and pH procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The acid-neutralizing capacity, total monomeric aluminum, nitrite, and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicated that the procedures for 16 of 17 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 93 percent of the samples met data-quality objectives for all analytes except acid-neutralizing capacity (85 percent of samples met objectives), total monomeric aluminum (83 percent of samples met objectives), total aluminum (85 percent of samples met objectives), and chloride (85 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project met the Troy Laboratory data-quality objectives for 87 percent of the samples analyzed. The P-sample (low-ionic-strength constituents) analysis had two outliers each in two studies. The T-sample (trace constituents) analysis and the N-sample (nutrient constituents) analysis had one outlier each in two studies. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 85 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were acid-neutralizing capacity, total aluminum and ammonium. Data-quality objectives were not met in 41 percent of samples analyzed for acid-neutralizing capacity, 50 percent of samples analyzed for total aluminum, and 44 percent of samples analyzed for ammonium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 76 percent of the samples analyzed for chloride, 80 percent of the samples analyzed for specific conductance, and 77 percent of the samples analyzed for sulfate.

  19. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples

    USGS Publications Warehouse

    Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.

    1996-01-01

    Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.

  20. PAH bioconcentration in Mytilus sp from Sinclair Inlet, WA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frazier, J.; Young, D.; Ozretich, R.

    1995-12-31

    Approximately 20 polynuclear aromatic hydrocarbons (PAH) were measured by GC/MS in seawater and whole soft tissues of the intertidal mussel Mytilus sp. collected in July 1991 within and around Puget Sound`s Sinclair Inlet. Low variability was observed in the water concentrations collected over three days at control sites, yielding reliable values for the exposure levels experienced by this bioindicator mollusk. Mean water concentrations of acenaphthene, phenanthrene, and fluoranthene in the control region were 2.7 {+-} 0.8, 2.8 {+-} 0.8, and 3.1 {+-} 0.7 ng/liter, respectively. Levels measured near sites of vessel activity were higher but much more variable; this reducedmore » the reliability of the tissue/water bioconcentration factors (BCF) obtained from these samples. An empirical model relating values of Log BCF and Log Kow for the control zone samples supports the utility of this estuarine bioindicator for monitoring general levels of PAH in nearshore surface waters.« less

  1. Ground-Water Quality Data in the Santa Clara River Valley Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Montrella, Joseph; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 460-square-mile Santa Clara River Valley study unit (SCRV) was investigated from April to June 2007 as part of the statewide Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw ground water used for public water supplies within SCRV, and to facilitate a statistically consistent basis for comparing water quality throughout California. Fifty-seven ground-water samples were collected from 53 wells in Ventura and Los Angeles Counties. Forty-two wells were selected using a randomized grid-based method to provide statistical representation of the study area (grid wells). Eleven wells (understanding wells) were selected to further evaluate water chemistry in particular parts of the study area, and four depth-dependent ground-water samples were collected from one of the eleven understanding wells to help understand the relation between water chemistry and depth. The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, potential wastewater-indicator compounds, and pharmaceutical compounds), a constituent of special interest (perchlorate), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial constituents. Naturally occurring isotopes (tritium, carbon-13, carbon-14 [abundance], stable isotopes of hydrogen and oxygen in water, stable isotopes of nitrogen and oxygen in nitrate, chlorine-37, and bromine-81), and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks or replicates, or samples for matrix spikes) were collected from approximately 26 percent of the wells, and the analyses of these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control results showed that the quality of the environmental data was good, with low bias and low variability, and as a result, less than 0.1 percent of the analytes detected in ground-water samples were censored. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered (or, supplied) to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Most constituents that were detected in ground-water samples were reported at concentrations below their established health-based thresholds. VOCs, pesticides and pesticide degradates, and potential wastewater-indicator compounds were detected in about 33 percent or less of the 42 SCRV grid wells. Concentrations of all detected organic constituents were below established health-based thresholds. Perchlorate was detected in approximately 12 percent of the SCRV grid wells; all concentrations reported were below the NL-CA threshold. Additional constituents, including major ions, trace elements, and nutrients were collected at 26 wells (16 grid wells and 10 understanding wells) of the 53 wells sampled f

  2. Results of quality-control sampling of water, bed sediment, and tissue in the Western Lake Michigan Drainages study unit of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzgerald, S.A.

    1997-01-01

    This report contains the quality control results of the Western Lake Michigan Drainages study unit of the National Water Quality Assessment Program. Quality control samples were collected in the same manner and contemporaneously with environmental samples during the first highintensity study phase in the unit (1992 through 1995) and amounted to approximately 15 percent of all samples collected. The accuracy and precision of hundreds of chemical analyses of surface and ground-water, bed sediment, and tissue was determined through the collection and analysis of field blanks, field replicates and splits, matrix spikes, and surrogates. Despite the several detections of analytes in the field blanks, the concentrations of most constituents in the environmental samples will likely be an order of magnitude or higher than those in the blanks. However, frequent detections, and high concentrations, of dissolved organic carbon (DOC) in several surface and ground-water blanks are probably significant with respect to commonly measured environmental concentrations, and the environmental data will have to be qualified accordingly. The precision of sampling of water on a percent basis, as determined from replicates and splits, was generally proportional to the concentration of the constituents, with constituents present in relatively high concentrations generally having less sampling variability than those with relatively low concentrations. In general, analytes with relatively high variability between replicates were present at concentrations near the reporting limit or were associated with relatively small absolute concentration differences, or both. Precision of replicates compared to that for splits in bed sediment samples was similar, thus eliminating sampling as a major source of variability in analyte concentrations. In the case the phthalates in bed sediment, contamination in either the field or laboratory could have caused the relatively large variability between replicate samples and between split samples.Variability of analyte concentrations in tissue samples was relatively low, being 29 percent or less for all constituents. Recoveries of most laboratory schedule 2001/2010 pesticide spike compounds in surfacewater samples were reasonably good. Low intrinsic method recovery resulted in relatively low recovery forp,p'-DDE, metribuzin, and propargite. In the case of propargite, decomposition with the environmental sample matrices was also indicated. Recoveries of two compounds, cyanazine and thiobencarb, might have been biased high due to interferences. The one laboratory schedule 2050/2051 field matrix pesticide spike indicated numerous operational problems with this method that biased recoveries either low or high. Recoveries of pesticides from both pesticide schedules in field spikes of ground-water samples generally were similar to those of field matrix spikes of surface- water samples. High maximum recoveries were noted for tebuthiuron, disulfoton, DCPA, and permethrin, which indicates the possible presence of interferents in the matrices for these compounds. Problems in the recoveries of pesticides on schedule 2050/2051 from ground-water samples generally were the same as those for surfacewater samples. Recoveries of VOCs in field matrix spikes were reasonable when consideration was given for the use of the micropipettor that delivered only about 80 percent on average of the nominal mass of spiked analytes. Finally, the recoveries of most surrogate compounds in surface and ground-water samples were reasonable. Problems in sample handling (for example, spillage) were likely not the cause of any of the low recoveries of spiked compounds.

  3. Remedial Investigation of Contaminant Mobility at Naval Weapons Station, Concord, California. Subtitle Appendix 2.5. 1986/1987.

    DTIC Science & Technology

    1988-06-01

    sandwiched between relatively dry, clayey silt beds of low permeability. c. The aquifer is confined under a piezometric head, and water rose a few feet in...2.5-D12 Field Measurements for Kiln Site Monitoring Wells (May and August 1987 ) ............... D15 2.5-D13 Well Development and Ground- water ...Analysis .... D16 2.5-D14 Water Sample Analysis (May 1987 ) ............... D17 2.5-D15 Water Sample Quality Control Data (May 1987 )... D18 2.5-D16 Water

  4. Hydrogeochemical Investigation of the Standard Mine Vicinity, Upper Elk Creek Basin, Colorado

    USGS Publications Warehouse

    Manning, Andrew H.; Verplanck, Philip L.; Mast, M. Alisa; Wanty, Richard B.

    2008-01-01

    Ground- and surface-water samples were collected in the vicinity of the Standard Mine in west-central Colorado in order to characterize the local ground-water flow system, determine metal concentrations in local ground water, and better understand factors controlling the discharge of metal-rich waters from the mine. The sampling program included a one-time sampling of springs, mine adits, and exploration pits in Elk Basin and Redwell Basin; repeated sampling throughout one year of Standard Mine Level 1 discharge and Elk Creek near its confluence with Coal Creek; and a one-time sampling of underground sites in Levels 3 and 5 of the Standard Mine. Samples were analyzed for major ions and trace elements, stable isotopes of hydrogen (2H/1H) and oxygen (18O/16O), strontium isotopes, and tritium and dissolved noble gases (including helium isotopes) for tritium/helium-3 age dating. No clear correlations were observed between natural ground-water discharge locations and map-scale faults and lithology. Surface observations and the location of ground-water discharge suggest that simple topography, rather than large-scale geologic features, primarily controls the occurrence and flow of shallow ground water in Elk Basin. Discrete inflows from cross faults or other features were not observed in Levels 3 and 5 of the Standard Mine. Instead, water entered the mine as relatively persistent dripping from gouge and breccia within the Standard fault, which both tunnels follow. Therefore, the Standard fault itself is probably the main pathway of ground-water flow from the shallow subsurface to the mine workings. Low pH (as low as 3.2) and elevated concentrations of zinc, lead, cadmium, copper, and manganese (commonly exceeding water-quality standards for Elk Creek) were measured in samples located within or immediately downgradient of areas where sulfides are abundant, including the Standard fault, the Elk Lode portal, and the breccia pipe in Redwell Basin. Concentrations of these metals were typically low and pH values were circumneutral at surrounding locations. Metal concentrations in samples collected from underground workings in the Standard Mine were also generally higher than in samples collected at aboveground sites located outside of sulfide-rich areas. Metal concentrations in discharge from the Level 1 tunnel were among the highest measured in Elk Basin. All of these observations suggest that sulfide-rich mineralized rock is the primary control on dissolved metal concentrations and pH in ground water in the Standard Mine vicinity. Waste-rock piles apparently exert another major control on metal concentrations and pH; the lowest pH and highest metal concentrations typically are found in discharge from waste-rock piles. Concentrations of several chemical constituents along with strontium isotope data indicate that none of the sampled waters could have been the primary source of metals in discharge from Level 1. Therefore, this study did not identify the primary source location for metals in Level 1 discharge. Possible sources must be located below Levels 3 and 5 or farther back into the mountainside than the ends of Levels 3 and 5. Apparent tritium/helium-3 ground-water ages ranged from 0 to 9 yr, and a considerable majority were <1 yr. Tritium data and computed initial tritium values (measured tritium plus measured tritiogenic helium-3) suggest that much of the ground water in the Standard Mine vicinity was weeks to months old rather than years old. Tritium, d2H, and d18O data from water entering into and discharging from the Standard Mine displayed spatial and temporal patterns indicating that these tracers were influenced by seasonal variations in their concentration in precipitation. The tracer data therefore suggest that ground water entering into and discharging from the Standard Mine was largely composed of water <1 yr old. Pronounced seasonal variations in geochemistry in Level 1 discharge also are consistent with short r

  5. Impacts of soil conditioners and water table management on phosphorus loss in tile drainage from a clay loam soil.

    PubMed

    Zhang, T Q; Tan, C S; Zheng, Z M; Welacky, T W; Reynolds, W D

    2015-03-01

    Adoption of waste-derived soil conditioners and refined water management can improve soil physical quality and crop productivity of fine-textured soils. However, the impacts of these practices on water quality must be assessed to ensure environmental sustainability. We conducted a study to determine phosphorus (P) loss in tile drainage as affected by two types of soil conditioners (yard waste compost and swine manure compost) and water table management (free drainage and controlled drainage with subirrigation) in a clay loam soil under corn-soybean rotation in a 4-yr period from 1999 to 2003. Tile drainage flows were monitored and sampled on a year-round continuous basis using on-site auto-sampling systems. Water samples were analyzed for dissolved reactive P (DRP), particulate P (PP), and total P (TP). Substantially greater concentrations and losses of DRP, PP, and TP occurred with swine manure compost than with control and yard waste compost regardless of water table management. Compared with free drainage, controlled drainage with subirrigation was an effective way to reduce annual and cumulative losses of DRP, PP, and TP in tile drainage through reductions in flow volume and P concentration with control and yard waste compost but not with swine manure compost. Both DRP and TP concentrations in tile drainage were well above the water quality guideline for P, affirming that subsurface loss of P from fine-textured soils can be one critical source for freshwater eutrophication. Swine manure compost applied as a soil conditioner must be optimized by taking water quality impacts into consideration. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  6. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York-July 1997 through June 1999

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.

  7. Quality-assurance data for routine water analyses by the U.S. Geological Survey laboratory in Troy, New York - July 2003 through June 2005

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride. 

  8. Performance of a novel high throughput method for the determination of VX in drinking water samples.

    PubMed

    Knaack, Jennifer S; Zhou, Yingtao; Magnuson, Matthew; Silvestri, Erin; Johnson, Rudolph C

    2013-03-05

    VX (O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate) is a highly toxic organophosphorus nerve agent, and even low levels of contamination in water can be harmful. Measurement of low concentrations of VX in aqueous matrixes is possible using an immunomagnetic scavenging technique and detection using liquid chromatography/tandem-mass spectrometry. Performance of the method was characterized in high-performance liquid chromatography (HPLC)-grade water preserved with sodium omadine, an antimicrobial agent, and sodium thiosulfate, a dechlorinating agent, over eight analytical batches with quality control samples analyzed over 10 days. The minimum reportable level was 25 ng/L with a linear dynamic range up to 4.0 μg/L. The mean accuracies for two quality control samples containing VX at concentrations of 0.250 and 2.00 μg/L were 102 ± 3% and 103 ± 6%, respectively. The stability of VX was determined in five tap water samples representing a range of water quality parameters and disinfection practices over a 91 day period. In preserved tap water samples, VX recovery was between 81 and 92% of the fortified amount, 2.0 μg/L, when analyzed immediately after preparation. Recovery of VX decreased to between 31 and 45% of the fortified amount after 91 days, indicating hydrolysis of VX. However, the preservatives minimized the hydrolysis rate to close to the theoretical limit. The ability to detect low concentrations of VX in preserved tap water 91 days after spiking suggests applicability of this method for determining water contamination with VX and utility during environmental remediation.

  9. Sequestration of priority pollutant PAHs from sediment pore water employing semipermeable membrane devices.

    PubMed

    Williamson, Kelly S; Petty, Jimmie D; Huckins, James N; Lebo, Jon A; Kaiser, Edwin M

    2002-11-01

    Semipermeable membrane devices (SPMDs) were employed to sample sediment pore water in static exposure studies under controlled laboratory conditions using (control pond and formulated) sediments fortified with 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs). The sediment fortification level of 750 ng/g was selected on the basis of what might be detected in a sediment sample from a contaminated area. The sampling interval consisted of 0, 4, 7, 14, and 28 days for each study. The analytical methodologies, as well as the extraction and sample cleanup procedures used in the isolation, characterization, and quantitation of 15 PPPAHs at different fortification levels in SPMDs, water, and sediment were reported previously (Williamson, M.S. Thesis, University of Missouri-Columbia, USA; Williamson et al., Chemosphere (This issue--PII: S0045-6535(02)00394-6)) and used for this project. Average (mean) extraction recoveries for each PPPAH congener in each matrix are reported and discussed. No procedural blank extracts (controls) were found to contain any PPPAH residues above the method quantitation limit, therefore, no matrix interferences were detected. The focus of this publication is to demonstrate the ability to sequester environmental contaminants, specifically PPPAHs, from sediment pore water using SPMDs and two different types of fortified sediment.

  10. Sequestration of priority pollutant PAHs from sediment pore water employing semipermeable membrane devices

    USGS Publications Warehouse

    Williamson, K.S.; Petty, J.D.; Huckins, J.N.; Lebo, J.A.; Kaiser, E.M.

    2002-01-01

    Semipermeable membrane devices (SPMDs) were employed to sample sediment pore water in static exposure studies under controlled laboratory conditions using (control pond and formulated) sediments fortified with 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs). The sediment fortification level of 750 ng/g was selected on the basis of what might be detected in a sediment sample from a contaminated area. The sampling interval consisted of 0, 4, 7, 14, and 28 days for each study. The analytical methodologies, as well as the extraction and sample cleanup procedures used in the isolation, characterization, and quantitation of 15 PPPAHs at different fortification levels in SPMDs, water, and sediment were reported previously (Williamson, M.S. Thesis, University of Missouri - Columbia, USA; Williamson et al., Chemosphere (This issue - PII: S0045-6535(02)00394-6)) and used for this project. Average (mean) extraction recoveries for each PPPAH congener in each matrix are reported and discussed. No procedural blank extracts (controls) were found to contain any PPPAH residues above the method quantitation limit, therefore, no matrix interferences were detected. The focus of this publication is to demonstrate the ability to sequester environmental contaminants, specifically PPPAHs, from sediment pore water using SPMDs and two different types of fortified sediment.

  11. A Strategy to Establish a Quality Assurance/Quality Control Plan for the Application of Biosensors for the Detection of E. coli in Water.

    PubMed

    Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza

    2017-01-03

    Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities.

  12. A Strategy to Establish a Quality Assurance/Quality Control Plan for the Application of Biosensors for the Detection of E. coli in Water

    PubMed Central

    Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza

    2017-01-01

    Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities. PMID:28054956

  13. Water quality parameters controlling the photodegradation of two herbicides in surface waters of the Columbia Basin, Washington.

    PubMed

    Furman, Olha S; Yu, Miao; Teel, Amy L; Watts, Richard J

    2013-11-01

    The water quality parameters nitrate-nitrogen, dissolved organic carbon, and suspended solids were correlated with photodegradation rates of the herbicides atrazine and 2,4-D in samples collected from four sites in the Columbia River Basin, Washington, USA. Surface water samples were collected in May, July, and October 2010 and analyzed for the water quality parameters. Photolysis rates for the two herbicides in the surface water samples were then evaluated under a xenon arc lamp. Photolysis rates of atrazine and 2,4-D were similar with rate constants averaging 0.025 h(-1) for atrazine and 0.039 h(-1) for 2,4-D. Based on multiple regression analysis, nitrate-nitrogen was the primary predictor of photolysis for both atrazine and 2,4-D, with dissolved organic carbon also a predictor for some sites. However, at sites where suspended solids concentrations were elevated, photolysis rates of the two herbicides were controlled by the suspended solids concentration. The results of this research provide a basis for evaluating and predicting herbicide photolysis rates in shallow surface waters. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York - July 2001 Through June 2003

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of

  15. Environmental Validation of Legionella Control in a VHA Facility Water System.

    PubMed

    Jinadatha, Chetan; Stock, Eileen M; Miller, Steve E; McCoy, William F

    2018-03-01

    OBJECTIVES We conducted this study to determine what sample volume, concentration, and limit of detection (LOD) are adequate for environmental validation of Legionella control. We also sought to determine whether time required to obtain culture results can be reduced compared to spread-plate culture method. We also assessed whether polymerase chain reaction (PCR) and in-field total heterotrophic aerobic bacteria (THAB) counts are reliable indicators of Legionella in water samples from buildings. DESIGN Comparative Legionella screening and diagnostics study for environmental validation of a healthcare building water system. SETTING Veterans Health Administration (VHA) facility water system in central Texas. METHODS We analyzed 50 water samples (26 hot, 24 cold) from 40 sinks and 10 showers using spread-plate cultures (International Standards Organization [ISO] 11731) on samples shipped overnight to the analytical lab. In-field, on-site cultures were obtained using the PVT (Phigenics Validation Test) culture dipslide-format sampler. A PCR assay for genus-level Legionella was performed on every sample. RESULTS No practical differences regardless of sample volume filtered were observed. Larger sample volumes yielded more detections of Legionella. No statistically significant differences at the 1 colony-forming unit (CFU)/mL or 10 CFU/mL LOD were observed. Approximately 75% less time was required when cultures were started in the field. The PCR results provided an early warning, which was confirmed by spread-plate cultures. The THAB results did not correlate with Legionella status. CONCLUSIONS For environmental validation at this facility, we confirmed that (1) 100 mL sample volumes were adequate, (2) 10× concentrations were adequate, (3) 10 CFU/mL LOD was adequate, (4) in-field cultures reliably reduced time to get results by 75%, (5) PCR provided a reliable early warning, and (6) THAB was not predictive of Legionella results. Infect Control Hosp Epidemiol 2018;39:259-266.

  16. Steroidal hormones and other endocrine active compounds in shallow groundwater in nonagricultural areas of Minnesota—Study design, methods, and data, 2009–10

    USGS Publications Warehouse

    Erickson, Melinda L.

    2012-01-01

    The U.S. Geological Survey, in cooperation with the Minnesota Pollution Control Agency, completed a study on the occurrence of steroidal hormones and other endocrine active compounds in shallow groundwater in nonagricultural areas of Minnesota during 2009–10. This report describes the study design and methods, and presents the data collected on steroidal hormones and other related compounds. Environmental and quality-control samples were collected from 40 wells as part of this study. Samples were analyzed by the U.S. Geological Survey National Water Quality Laboratory for 16 steroidal hormones and 4 other related compounds, of which all but 2 compounds are endocrine active compounds. Most of the water samples did not contain detectable concentrations of any of the 20 compounds analyzed. Water samples from three wells had detectable concentrations of one or more compounds. Bisphenol A was detected in samples from three wells, and trans-diethylstilbestrol was detected in one of the samples in which bisphenol A also was detected.

  17. The importance of quality control in validating concentrations of contaminants of emerging concern in source and treated drinking water samples.

    EPA Science Inventory

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods w...

  18. Recommendations for constructing forest stream crossings to control soil losses

    Treesearch

    Pamela J. Edwards; Jingxin Wang; Joshua T. Stedman

    2009-01-01

    Stream water samples were collected once daily and throughout storms from a small forested watershed in north central West Virginia for approximately 8 years. The turbidities of the samples were measured to determine how water quality changed in response to the construction of three associated stream crossings. The influence of the...

  19. Determination of the delta(18O/16O)of Water: RSIL Lab Code 489

    USGS Publications Warehouse

    Revesz, Kinga; Coplen, Tyler

    2008-01-01

    The purpose of the technique described by the Reston Stable Isotope Laboratory (RSIL) lab code 489 is to present a method to determine the delta(180/160), abbreviated as delta-180, of water. This delta-18O measurement of water also is a component of National Water Quality Laboratory (NWQL in USGS) schedules 1142 and 1172. Water samples are loaded into glass sample containers on a vacuum manifold to equilibrate gaseous CO2 at constant temperature (25 deg C) with water samples. After loading water samples on the vacuum manifold, air is evacuated through capillary to avoid evaporation, and CO2 is added. The samples are shaken to increase the equilibration rate of water and CO2. When isotopic equilibrium has been attained, an aliquot of CO2 is extracted sequentially from each sample container, separated from water vapor by means of a dry ice trap, and introduced into a dual-inlet isotope-ratio mass spectrometer (DI-IRMS) for determination of the delta-18O value. There is oxygen isotopic fractionation between water and CO2, but it is constant at constant temperature. The DI-IRMS is a DuPont double-focusing mass spectrometer. It has a double collector. One ion beam passes through a slit in a forward collector and is collected in the rear collector. The other ion beams are collected in the front collector. The instrument is capable of measuring mass/charge (m/z) 44 and 45 or 44 and 46 by changing the ion-accelerating voltage under computer control. The ion beams from these m/z values are as follows: m/z 44=CO2=12C16O16O, m/z 45=CO2=13C16O16O primarily, and m/z 46 = CO2=12C16O18O primarily. The data acquisition and control software calculates delta-18O values.

  20. 10 CFR Appendix A to Subpart C of... - Sampling Plan for Enforcement Testing of Covered Consumer Products and Certain High-Volume...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in Step (c). (6) For an energy or water consumption standard (ECS), compute the upper control limit (UCL2) for the mean of the combined first and second samples using the DOE ECS as the desired mean and a...)(1). (7) For an energy or water consumption standard (ECS), compare the combined sample mean (x2) to...

  1. 10 CFR Appendix A to Subpart C of... - Sampling Plan for Enforcement Testing of Covered Consumer Products and Certain High-Volume...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in Step (c). (6) For an energy or water consumption standard (ECS), compute the upper control limit (UCL2) for the mean of the combined first and second samples using the DOE ECS as the desired mean and a...)(1). (7) For an energy or water consumption standard (ECS), compare the combined sample mean (x2) to...

  2. 10 CFR Appendix A to Subpart C of... - Sampling Plan for Enforcement Testing of Covered Consumer Products and Certain High-Volume...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... in Step (c). (6) For an energy or water consumption standard (ECS), compute the upper control limit (UCL2) for the mean of the combined first and second samples using the DOE ECS as the desired mean and a...)(1). (7) For an energy or water consumption standard (ECS), compare the combined sample mean (x2) to...

  3. On-Line Analyzer For Monitoring Trace Amounts Of Oil In Turbid Waters

    NASA Astrophysics Data System (ADS)

    Niemela, P.; Jaatinen, J.

    1986-05-01

    This report presents an automated analyzer which continuously monitors oil content of a sample water stream that flows through the analyzer. The measuring principle is based on the absorption of infrared radiation by oil molecules contained in the sample water. The wavelength band that is used in the measurement is at 3.4 μm, where different types of oils show nearly equal absorption. Another wavelength band of 3.6 μm, where oil has no absorption, is used to compensate the effect of turbidity, which is due to solid particles and oil droplets contained in the sample water. Before entering the analyzer the sample water flow is properly homogenized. To compensate the strong absorption by water molecules in these wavelength bands the sample water is compared with reference water. This is done by directing them alternately through the same measuring cell. The reference water is obtained from the sample water by ultrafiltration and it determines the base line for the contaminated sample water. To ensure the stability of the base line, temperature and pressure differences of the two waters are kept within adequate ranges. Areas of application of the analyzer are wide ranging i.a. from ships' discharge waters to waste waters of industrial processes. The first application of the analyzer is on board oil tankers to control the discharge process of bilge and ballast waters. The analyzer is the first that fully corresponds to the stringent regulations for oil content monitors by the International Maritime Organization (IMO). Pilot installations of the analyzer are made on industrial plants.

  4. Flint Water Crisis Caused By Interrupted Corrosion Control: Investigating "Ground Zero" Home.

    PubMed

    Pieper, Kelsey J; Tang, Min; Edwards, Marc A

    2017-02-21

    Flint, Michigan switched to the Flint River as a temporary drinking water source without implementing corrosion control in April 2014. Ten months later, water samples collected from a Flint residence revealed progressively rising water lead levels (104, 397, and 707 μg/L) coinciding with increasing water discoloration. An intensive follow-up monitoring event at this home investigated patterns of lead release by flow rate-all water samples contained lead above 15 μg/L and several exceeded hazardous waste levels (>5000 μg/L). Forensic evaluation of exhumed service line pipes compared to water contamination "fingerprint" analysis of trace elements, revealed that the immediate cause of the high water lead levels was the destabilization of lead-bearing corrosion rust layers that accumulated over decades on a galvanized iron pipe downstream of a lead pipe. After analysis of blood lead data revealed spiking lead in blood of Flint children in September 2015, a state of emergency was declared and public health interventions (distribution of filters and bottled water) likely averted an even worse exposure event due to rising water lead levels.

  5. Rainfall, Discharge, and Water-Quality Data During Stormwater Monitoring, July 1, 2007, to June 30, 2008; Halawa Stream Drainage Basin and the H-1 Storm Drain, Oahu, Hawaii

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.; Young, Stacie T.M.

    2008-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at four stations, and water-quality data at six stations, which include the four continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2007, and June 30, 2008. A total of 16 environmental samples were collected over two storms during July 1, 2007, to June 30, 2008, within the Halawa Stream drainage area. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some samples were analyzed for only a partial list of these analytes because an insufficient volume of sample was collected by the automatic samplers. Three additional quality-assurance/quality-control samples were collected concurrently with the storm samples. A total of 16 environmental samples were collected over four storms during July 1, 2007, to June 30, 2008 at the H-1 Storm Drain. All samples at this site were collected using an automatic sampler. Samples generally were analyzed for total suspended solids, nutrients, chemical oxygen demand, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc), although some samples were analyzed for only a partial list of these analytes. During the storm of January 29, 2008, 10 discrete samples were collected. Varying constituent concentrations were detected for the samples collected at different times during this storm event. Two quality-assurance/quality-control samples were collected concurrently with the storm samples. Three additional quality-assurance/quality-control samples were collected during routine sampler maintenance to check the effectiveness of equipment-cleaning procedures.

  6. Changes of erythrocyte-metric parameters in Pelophylax ridibundus (Amphibia: Anura: Ranidae) inhabiting water bodies with different types of anthropogenic pollution in Southern Bulgaria.

    PubMed

    Zhelev, Zhivko; Popgeorgiev, Georgi; Ivanov, Ivan; Boyadzhiev, Peter

    2017-07-01

    The article presents the basic erythrocyte-metric parameters: cell length (EL) and width (EW), EL/EW, erythrocyte size (ES), nucleus length (NL) and width (NW), NL/NW, nucleus size (NS) and nucleocytoplasmic ratio (NS/ES) in the wild populations of marsh frogs Pelophylax ridibundus from five water bodies in Southern Bulgaria (two rivers and three reservoirs) with different degrees and types of anthropogenic pollution (less disrupted water basins, domestic sewage pollution and heavy metal pollution). The changes in erythrocyte-metric parameters depend on concentrations and types of toxicant and, to a lesser extent, on the type of water basin. We found that when P. ridibundus populations live in conditions of domestic sewage pollution, EL, EW and ES increase in comparison with the control samples, with regard to an elongated elliptical cell shape. Simultaneously, NL, NW and NS did not undergo any significant changes when compared with the control samples. The nuclei had elliptical shape. In the populations from the water basins with heavy metal pollution, EL, EW, ES, NL, NW and NS decreased. The cells and nuclei had a circular shape. NS/ES decreased when compared with the control sample, regardless of the type of toxicants.

  7. A low-cost intervention for cleaner drinking water in Karachi, Pakistan.

    PubMed

    Luby, S; Agboatwalla, M; Raza, A; Sobel, J; Mintz, E; Baier, K; Rahbar, M; Qureshi, S; Hassan, R; Ghouri, F; Hoekstra, R M; Gangarosa, E

    2001-01-01

    To pilot test an inexpensive, home-based water decontamination and storage system in a low-income neighborhood of Karachi. Fifty households received a 20-L plastic water storage vessel with a high-quality spout and a regular supply of diluted hypochlorite solution. Twenty-five control households were recruited. Water samples were collected at baseline and during unannounced follow-up visits 1, 3, 6, and 10 weeks later. Baseline drinking water samples among intervention households were contaminated with a mean 9397 colony-forming units (cfu)/100 mL of thermotolerant coliforms compared with a mean 10,990 cfu/100 mL from controls. After intervention the mean concentration of thermotolerant coliforms decreased by 99.8% among the intervention households compared with an 8% reduction among controls. Two years after vessel distribution, 34 (68%) of the families were still using the vessel. Thirteen of the households had stopped using their vessel because it had broken after more than 6 months of use, a pattern most consistent with ultraviolet radiation-induced degradation of the plastic. In a highly contaminated environment, a specifically designed water storage container and in-home water chlorination was acceptable and markedly improved water quality. Where plastic water vessels will be exposed to substantial sunlight, ultraviolet light stabilizers should be incorporated into the plastic.

  8. Chemical quality of tap water in Madrid: multicase control cancer study in Spain (MCC-Spain).

    PubMed

    Fernández-Navarro, Pablo; Villanueva, Cristina M; García-Pérez, Javier; Boldo, Elena; Goñi-Irigoyen, Fernando; Ulibarrena, Enrique; Rantakokko, Panu; García-Esquinas, Esther; Pérez-Gómez, Beatriz; Pollán, Marina; Aragonés, Nuria

    2017-02-01

    Chronic consumption of water, which contains contaminants, may give rise to adverse health effects. The Madrid region, covered by the population-based multicase-control (MCC-Spain) study, includes two drinking water supply areas. The different sources of the water, coupled together with the possible differences in water management, mean that there may be differences in drinking water quality. In the context of the MCC study, our aims were to describe contaminant concentrations in tap water drawn from various sampling points distributed around the region, assess these concentrations by reference to guideline values and study possible differences between the two supply areas. Tap water samples were collected from 34 sampling points in 7 towns in the Madrid region (19-29 April 2010), and 23 contaminants (metals, nitrates, disinfection by-product and Mutagen X levels) were quantified. We undertook a descriptive analysis of the contaminant concentrations in the water and compared them between the two water supply areas (Wilcoxon test). We created maps representing the distribution of the concentrations observed at water sampling points and assessed the correlations (Spearman's coefficient) between the different parameters measured. The concentrations of the contaminants were below guideline values. There were differences between the two supply areas in concentration of nitrates (p value = 0.0051) and certain disinfection by-products. While there were positive correlations (rho >0.70) among some disinfection by-products, no correlations were found in metals or nitrates. The differences in nitrate levels could be linked to differences in farming/industrial activities in the catchment areas and in disinfection by-products might be related to the existence of different treatment systems or bromine content in source waters.

  9. Microbial diversity in firework chemical exposed soil and water samples collected in Virudhunagar district, Tamil Nadu, India.

    PubMed

    Dhasarathan, P; Theriappan, P; Ashokraja, C

    2010-03-01

    Microbial diversity of soil and water samples collected from pyrochemicals exposed areas of Virdhunagar district (Tamil Nadu, India) was studied. Soil and water samples from cultivable area, waste land and city area of the same region were also studied for a comparative acount. There is a remarkable reduction in total heterotrophic bacterial population (THB) in pyrochemicals exposed soil and water samples (42 × 10(4) CFU/g and 5.6 × 10(4) CFU/ml respectively), compared to the THB of cultivable area soil and water samples (98 × 10(7) CFU/g and 38.6 × 10(7) CFU/ml). The generic composition the THB of the pyrochemicals exposed samples too exhibited considerable change compared to other samples. Pseudomonas sp. was the predominant one (41.6%) followed by Achromobacter sp. (25%) in pyrochemical exposed soil and Pseudomonas sp. was the predominant one (25%) in pyrochemical exposed water samples followed by Bacillus sp. (25%) and Micrococcus sp. (16.6%). It was observed that Cornybacterium sp. and Micrococcus sp. were absent completely in pyrochemical exposed soil and Achromobacter sp. was missing in the pyrochemical exposed water samples, which were present in the other samples. The outcome of this study clearly demonstrates that pollutants such as chemicals used in pyrotechniques affect the microbial biodiversity and suitable measures have to be taken to control the pollution level and to save biodiversity.

  10. Microplastics, Macroproblems?

    NASA Astrophysics Data System (ADS)

    Greene, V.; Adams, S.; Adams, A.

    2017-12-01

    Microplastics and plastics have polluted water all over the world including the Great Lakes. Microplastics can result from plastics that have broken up into smaller pieces or they can be purposely made and used in a variety of products. The size of a microplastic is less than 5 mm in length. These plastics can cause problems because they are non-biodegradable. Animals that have ingested these plastics have had reduced reproductive rates, health problems, and have even died from malnutrition. Our goal is to learn more about this issue. To do this, we will take water samples from different areas along the Gulf of Mexico and inland bays along the Florida coastline and compare the amount of microplastics found in each area. To analyze our samples we will vacuum filter water samples using gridded filter paper. We will then organize these samples by size and color. The control for our experiment will be filtered water. Our hypothesis is that Gulf of Mexico water samples will have more microplastics than the Bay water samples. We want to research this topic because microplastics can harm our ecosystems by affecting the health of marine animals.

  11. HACCP-Based Programs for Preventing Disease and Injury from Premise Plumbing: A Building Consensus

    PubMed Central

    McCoy, William F.; Rosenblatt, Aaron A.

    2015-01-01

    Thousands of preventable injuries and deaths are annually caused by microbial, chemical and physical hazards from building water systems. Water is processed in buildings before use; this can degrade the quality of the water. Processing steps undertaken on-site in buildings often include conditioning, filtering, storing, heating, cooling, pressure regulation and distribution through fixtures that restrict flow and temperature. Therefore, prevention of disease and injury requires process management. A process management framework for buildings is the hazard analysis and critical control point (HACCP) adaptation of failure mode effects analysis (FMEA). It has been proven effective for building water system management. Validation is proof that hazards have been controlled under operating conditions and may include many kinds of evidence including cultures of building water samples to detect and enumerate potentially pathogenic microorganisms. However, results from culture tests are often inappropriately used because the accuracy and precision are not sufficient to support specifications for control limit or action triggers. A reliable negative screen is based on genus-level Polymerase Chain Reaction (PCR) for Legionella in building water systems; however, building water samples with positive results from this test require further analysis by culture methods. PMID:26184325

  12. HACCP-Based Programs for Preventing Disease and Injury from Premise Plumbing: A Building Consensus.

    PubMed

    McCoy, William F; Rosenblatt, Aaron A

    2015-07-09

    Thousands of preventable injuries and deaths are annually caused by microbial, chemical and physical hazards from building water systems. Water is processed in buildings before use; this can degrade the quality of the water. Processing steps undertaken on-site in buildings often include conditioning, filtering, storing, heating, cooling, pressure regulation and distribution through fixtures that restrict flow and temperature. Therefore, prevention of disease and injury requires process management. A process management framework for buildings is the hazard analysis and critical control point (HACCP) adaptation of failure mode effects analysis (FMEA). It has been proven effective for building water system management. Validation is proof that hazards have been controlled under operating conditions and may include many kinds of evidence including cultures of building water samples to detect and enumerate potentially pathogenic microorganisms. However, results from culture tests are often inappropriately used because the accuracy and precision are not sufficient to support specifications for control limit or action triggers. A reliable negative screen is based on genus-level Polymerase Chain Reaction (PCR) for Legionella in building water systems; however, building water samples with positive results from this test require further analysis by culture methods.

  13. [Sanitary control of food in Mexico city].

    PubMed

    Sartí-Gutiérrez, E J; Parrilla-Cerrillo, C; Vázquez-Barojas, S; Kawashima-Hashimoto, L; Farías-Rodríguez, A; García-Juárez, C

    1989-01-01

    This work was undertaken as to avoid health risks to tourism in the "XIIth Soccer World Cup, Mexico 86". The above project was carried out through proper quality control of foods, drinking water as well as a definite care of personal hygiene of all those involved in the catering business (132 restaurants were included). The mentioned report informs only of the work of the National Public Health Laboratory in the Sanitary Epidemiological Program. The following products were analyzed: 133 water samples, 272 animated and nonliving surfaces, and 399 foods. Twenty seven percent of water samples were rejected, as well as 85% of the different surfaces and 60% of the food samples. High counts of mesophilic aerobics, followed by coliforms, S. aureus and Salmonella sp., were the principal specimens encountered. Therefore, it was suggested the permanent development of a sanitary epidemiological program.

  14. Groundwater Monitoring Plan. Volume 2. Final Quality Assurance Project Plan

    DTIC Science & Technology

    1993-10-01

    5 Table 4-2. US EPA Drinking Water MCLs ........................................ 4-6 Table 5-1. Sample Bottle Requirements, Preservation, and Holding... drinking water . " The types of quality control samples that will be collected during the Canal Creek groundwater monitoring program. ]- Jacobs...Revision No.: 0 Date: 10/27/93 Page: 6 of 9 Canal Creek Area, APG-EA, Maryland Groundwater Monitoring Plan, VOLUME I1 Table 4-2. US EPA Drinking Water

  15. Properties of microcement mortar with nano particles

    NASA Astrophysics Data System (ADS)

    Alimeneti, Narasimha Reddy

    Carbon nanotubes (CNT) and Carbon nanofibers (CNF) are one of the toughest and stiffest materials in the world presently with extreme properties yet to be discovered in terms of elastic modulus and tensile strength. Due to the advanced properties of these materials they are being used in almost all fields of science at nanolevel and are being used in construction industry recently for improvement of material properties. Microcement is fine ground cement which as half the particle size of ordinary Portland cement. In this research the behavior of cement mortar of micro cement with the addition of nanoparticles is studied. Due to high aspect ratio and strong van der Waal forces between the particles of CNT and CNF, they agglomerate and form bundles when mixed with water, sonication method is used to mix nanoparticles with few drops of surfactant and super plasticizer. Mechanical properties such as compressive strength and flexural strength with CNT and CNF composites are examined and compared with control samples. 0.1% and 0.05 % of nanoparticles (both CNT and CNF) by the weight of cement are used in this research and 0.8% of super plasticizer by weight of cement was also used along with 0.4, 0.45 and 0.50 water cement ratios for making specimens for compression test. The compressive strength results are not satisfactory as there was no constant increase in strength with all the composites, however strength of few nanocomposites increased by a good percentage. 0.5 water cement ratio cement mortar had compressive strength of 7.15 ksi (49.3 MPa), whereas sample with 0.1% CNT showed 8.38 ksi (57.8 MPa) with 17% increase in strength after 28 days. Same trend was followed by 0.4 water cement ratio as the compressive strength of control sample was 8.89 ksi (61.3 MPa), with 0.05% of CNT strength increased to 10.90 ksi (75.2 MPa) with 23% increase in strength. 0.4 water cement ratio was used for flexural tests including 0.1%, 0.05% of CNT and 0.1%, 0.05% of CNF with 0.008 ratio of super plasticizer. Results showed that there was a significant increase in strength initially but gradually decreased as the time increase and showed decreased strength at 28 days when compared to control samples. Flow cone results are quite satisfying as the flow is significantly increased with the addition of nanoparticles. Time of efflux of control sample is 16.22 sec whereas for specimen with CNT had a time of efflux 12.67 sec and sample with CNF showed 13.65 seconds. Setting time test was carried on 0.4 water cement ratio. Composites with nanoparticles exhibited faster setting when compared to its control sample. Bleeding was not observed with the nanoparticles in the cement mortar. Shrinkage test was conducted on sample with 0.4 water cement ratio with 0.05% of CNT and CNF. Shrinkage was very small in the samples with nanoparticles.

  16. Geochemical processes and the effects of natural organic solutes on the solubility of selenium in coal-mine backfill samples from the Powder River basin, Wyoming

    USGS Publications Warehouse

    See, R.B.; Reddy, K.J.; Vance, G.F.; Fadlelmawla, A.A.; Blaylock, M.J.

    1995-01-01

    Geochemical processes and the effects of natural organic solutes on the solubility of selenium in coal-mine backfill aquifers were investigated. Backfill and ground-water samples were collected at coal mines in the Powder River Basin, Wyoming. Backfill was generally dominated by aluminum (14,400 to 49,000 mg/kg (milligrams per kilogram)), iron (3,330 to 23,200 mg/kg), and potassium (7,950 to 18,000 mg/kg). Backfill saturated-paste selenium concentrations ranged from 1 to 156 mg/kg (microsiemens per kilogram). Ground-water total selenium concentrations ranged from 3 to 125 mg/L. Dissolved organic carbon in all ground-water samples was dominated by hydrophobic and hydrophilic acids (38 to 84 percent). Selenite sorption/desorption experiments were conducted using background solutions of distilled-deionized water, 0.1 molar calcium chloride, and isolated hydrophobic and hydrophilic acids. Selenite sorption was larger when 0.1 molar calcium chloride was used. The addition of hydrophilic acid decreased selenite sorption more than the addition of hydrophobic acids. Geochemical modelling was used to predict the solid phases controlling dissolved selenium concentrations and to evaluate the effects of dissolved organic carbon on selenium solubility. Results suggested that 55 to 90 percent of selenium in backfill precipitation/dissolution extracts was dominated by magnesium selenate ion pairs. Dissolved organic carbon had little effect on selenium speciation. A redox chamber was constructed to control Eh and pH in water and backfill-core sample suspensions. The response of selenite and selenate in water samples to redox conditions did not follow thermodynamic predictions. Reduction of selenate in water samples did not occur at any of the redox levels tested.

  17. Health risk assessment of fluoride in drinking water from Anhui Province in China.

    PubMed

    Gao, Hong-jian; Jin, You-qian; Wei, Jun-ling

    2013-05-01

    This study analyzes the concentrations and health risks of fluoride in 249 drinking water samples collected from different regions of Anhui Province in China. Results indicated that fluoride content in drinking water ranged from 0.12 to 1.94 mg L(-1) (mean = 0.57 mg L(-1)) in the following order: Huaibei plain region > Jianghuai hill region ≈ Dabieshan mountainous region > plain along the Yangtze River region > southern Anhui mountainous region. The fluoride contents were less than 0.50 mg L(-1) in 66.66 % of the drinking water samples, 0.51-1.0 mg L(-1) in 23.29 %, and higher than 1.0 mg L(-1) in 12.04 %. The fluoride levels in some samples were lower than the recommended values for controlling dental caries (0.50-1.0 mg L(-1)). The total fluoride intake from drinking water was between 0.14 and 2.33 mg per day in different regions of the province, supposing an individual consumes 1.2 L of water per day. Therefore, measures should be taken to increase fluoride intake in the Jianghuai hill region, Dabieshan mountainous region, plain along the Yangtze River, and southern Anhui mountainous region to control dental caries. On the other hand, the fluoride levels must be reduced in the Huaibei plain region to decrease endemic fluorosis. The results serve as crucial guidelines for managing fluoride safety in drinking water and controlling endemic fluorosis in different regions of Anhui Province.

  18. Causes of toxicity to Hyalella azteca in a stormwater management facility receiving highway runoff and snowmelt. Part II: salts, nutrients, and water quality.

    PubMed

    Bartlett, A J; Rochfort, Q; Brown, L R; Marsalek, J

    2012-01-01

    The Terraview-Willowfield Stormwater Management Facility (TWSMF) features a tandem of stormwater management ponds, which receive inputs of multiple contaminants from highway and residential runoff. Previous research determined that benthic communities in the ponds were impacted by poor habitat quality, due to elevated sediment concentrations of metals and polycyclic aromatic hydrocarbons (PAHS), and salinity in the overlying water, but did not address seasonal changes, including those caused by the influx of contaminants with the snowmelt. In order to address this issue, water and sediment samples were collected from the TWSMF during the fall and spring, and four-week sediment toxicity tests were conducted with Hyalella azteca. The effects of metals and PAHs are discussed in a companion paper; the effects of road salt, nutrients, and water quality are discussed here. After exposure to fall samples, survival of Hyalella was reduced (64-74% of controls) at three out of four sites, but growth was not negatively affected. After exposure to spring samples, survival was 0-75% of controls at the two sites furthest downstream, and growth was significantly lower in four out of five sites when comparing Hyalella exposed to site water overlying site sediment versus control water overlying site sediment. Toxicity appeared to be related to chloride concentrations: little or no toxicity occurred in fall samples (200 mg Cl(-)/L), and significant effects on survival and growth occurred in spring samples above 1550 mg Cl(-)/L and 380 mg Cl(-)/L, respectively. Sodium chloride toxicity tests showed similar results: four-week LC50s and EC25s (growth) were 1200 and 420 mg Cl(-)/L, respectively. Although water quality and nutrients were associated with effects observed in the TWSMF, chloride from road salt was the primary cause of toxicity in this study. Chloride persists during much of the year at concentrations representing a significant threat to benthic communities in the TWSMF. Copyright © 2011. Published by Elsevier B.V.

  19. [Identification and isolation of non-tuberculous mycobacteria from environmental samples].

    PubMed

    Cafri, Uğur; Aslan, Gönül; Direkel, Sahin; Tarhan, Gülnur; Ceyhan, Ismail; Emekdaş, Gürol

    2010-07-01

    Non-tuberculous mycobacteria (NTM) found frequently in tap water and environment cause important opportunistic infections in immunocompromised patients. The aim of this study was to isolate and identify non-tuberculous mycobacteria in soil, raw milk and water distribution system samples in Mersin (a province located at Mediterranean region of Turkey). A total of 101 water, 124 soil and 40 milk samples collected from the central part and suburban parts of Mersin during November 2003-May 2004 period were included in the study. Water samples were collected from 29 different water distribution systems; soil samples from different parks and gardens and milk samples from raw milks sold at different districts. After the samples were processed by homogenization and decontamination, acid-fast staining and culture into Löwenstein-Jensen medium were performed. Acid-fast bacilli isolated from culture medium were identified by using conventional methods, polymerase chain reaction (PCR)-RFLP (Restriction Fragment Length Polymorphism) and INNO-LIPA Mycobacteria methods. NTM were identified from 4.9% (5/101) of water samples and 0.8% (1/124) of soil samples by culture and PCR. No NTM were detected in the raw milk samples. Three of the NTM strains isolated from water samples were defined as Mycobacterium chelonae type III and two as Mycobacterium kansasii type II. One NTM strain isolated from soil was defined as Mycobacterium fortuitum. It was of note that two of the five NTM positive water samples were tap water samples collected from hospitals. It was concluded that NTM colonization/contamination of water and environment in the hospitals was a potential risk factor in terms of nosocomial infections. Thus surveillance cultures of the water systems and the medical devices in the hospital are necessary to fix the source of NTM, to identify and type the strains and to establish effective control measures such as sterilization, disinfection, maintenance and modernization of water systems.

  20. Hydrologic and Water-Quality Responses in Shallow Ground Water Receiving Stormwater Runoff and Potential Transport of Contaminants to Lake Tahoe, California and Nevada, 2005-07

    USGS Publications Warehouse

    Green, Jena M.; Thodal, Carl E.; Welborn, Toby L.

    2008-01-01

    Clarity of Lake Tahoe, California and Nevada has been decreasing due to inflows of sediment and nutrients associated with stormwater runoff. Detention basins are considered effective best management practices for mitigation of suspended sediment and nutrients associated with runoff, but effects of infiltrated stormwater on shallow ground water are not known. This report documents 2005-07 hydrogeologic conditions in a shallow aquifer and associated interactions between a stormwater-control system with nearby Lake Tahoe. Selected chemical qualities of stormwater, bottom sediment from a stormwater detention basin, ground water, and nearshore lake and interstitial water are characterized and coupled with results of a three-dimensional, finite-difference, mathematical model to evaluate responses of ground-water flow to stormwater-runoff accumulation in the stormwater-control system. The results of the ground-water flow model indicate mean ground-water discharge of 256 acre feet per year, contributing 27 pounds of phosphorus and 765 pounds of nitrogen to Lake Tahoe within the modeled area. Only 0.24 percent of this volume and nutrient load is attributed to stormwater infiltration from the detention basin. Settling of suspended nutrients and sediment, biological assimilation of dissolved nutrients, and sorption and detention of chemicals of potential concern in bottom sediment are the primary stormwater treatments achieved by the detention basins. Mean concentrations of unfiltered nitrogen and phosphorus in inflow stormwater samples compared to outflow samples show that 55 percent of nitrogen and 47 percent of phosphorus are trapped by the detention basin. Organic carbon, cadmium, copper, lead, mercury, nickel, phosphorus, and zinc in the uppermost 0.2 foot of bottom sediment from the detention basin were all at least twice as concentrated compared to sediment collected from 1.5 feet deeper. Similarly, concentrations of 28 polycyclic aromatic hydrocarbon compounds were all less than laboratory reporting limits in the deeper sediment sample, but 15 compounds were detected in the uppermost 0.2 foot of sediment. Published concentrations determined to affect benthic aquatic life also were exceeded for copper, zinc, benz[a]anthracene, phenanthrene, and pyrene in the shallow sediment sample. Isotopic composition of water (oxygen 18/16 and hydrogen 2/1 ratios) for samples of shallow ground water, lakewater, and interstitial water from Lake Tahoe indicate the lake was well mixed with a slight ground-water signature in samples collected near the lakebed. One interstitial sample from 0.8 foot beneath the lakebed was nearly all ground water and concentrations of nitrogen and phosphorus were comparable to concentrations in shallow ground-water samples. However, ammonium represented 65 percent of filtered nitrogen in this interstitial sample, but only 10 percent of the average nitrogen in ground-water samples. Nitrate was less than reporting limits in interstitial water, compared with mean nitrate concentration of 750 micrograms per liter in ground-water samples, indicating either active dissimilative nitrate reduction to ammonium by micro-organisms or hydrolysis of organic nitrogen to ammonium with concomitant nitrate reduction. The other interstitial sample falls along a mixing line between ground water and lake water and most of the nitrogen was organic nitrogen.

  1. Ground-Water Quality Data in the Southeast San Joaquin Valley, 2005-2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Burton, Carmen A.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 3,800 square-mile Southeast San Joaquin Valley study unit (SESJ) was investigated from October 2005 through February 2006 as part of the Priority Basin Assessment Project of Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment project was developed in response to the Ground-Water Quality Monitoring Act of 2001 and is being conducted by the California State Water Resources Control Board (SWRCB) in collaboration with the U.S. Geological Survey (USGS) and the Lawrence Livermore National Laboratory (LLNL). The SESJ study was designed to provide a spatially unbiased assessment of raw ground-water quality within SESJ, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 99 wells in Fresno, Tulare, and Kings Counties, 83 of which were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 16 of which were sampled to evaluate changes in water chemistry along ground-water flow paths or across alluvial fans (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine, and 1,2,3-trichloropropane), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon), and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, samples for matrix spikes) were collected at approximately 10 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control data resulted in censoring of less than 1 percent of the detections of constituents measured in ground-water samples. This study did not attempt to evaluate the quality of drinking water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable drinking-water quality. Regulatory thresholds apply to the treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and other health-based thresholds established by the U.S. Environmental Protection Agency and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns by CDPH. Two VOCs were detected above health-based thresholds: 1,2-dibromo-3-chloropropane (DBCP), and benzene. DBCP was detected above the U.S. Environmental Protections Agency's maximum contaminant level (MCL-US) in three grid wells and five understanding wells. Benzene was detected above the CDPH's maximum contaminant level (MCL-CA) in one grid well. All pesticide detections were below health-based thresholds. Perchlorate was detected above its maximum contaminate level for California in one grid well. Nitrate was detected above the MCL-US in six samples from understanding wells, of which one was a public supply well. Two trace elements were detected above MCLs-US: arsenic and uranium. Arsenic was detected above the MCL-US in four grid wells and two understanding wells; uranium was detected above the MCL-US in one grid well and one understanding well. Gross alpha radiation was detected above MCLs-US in five samples; four of them understanding wells, and uranium isotope activity was greater than the MCL-US for one understanding well

  2. Method Development and Monitoring of Cyanotoxins in Water

    EPA Science Inventory

    This presentation describes method development of two ambient water LC/MS/MS methods for microcystins, cylindrospermopsin and anatoxin-a. Ruggedness of the methods will be demonstrated by evaluation of quality control samples derived from various water bodies across the country.

  3. Water quality concerns due to forest fires: polycyclic aromatic hydrocarbons (PAH) contamination of groundwater from mountain areas.

    PubMed

    Mansilha, C; Carvalho, A; Guimarães, P; Espinha Marques, J

    2014-01-01

    Water quality alterations due to forest fires may considerably affect aquatic organisms and water resources. These impacts are cumulative as a result of pollutants mobilized from fires, chemicals used to fight fire, and postfire responses. Few studies have examined postfire transport into water resources of trace elements, including the polycyclic aromatic hydrocarbons (PAH), which are organic pollutants produced during combustion and are considered carcinogenic and harmful to humans. PAH are also known to adversely affect survival, growth, and reproduction of many aquatic species. This study assessed the effects of forest wildfires on groundwater from two mountain regions located in protected areas from north and central Portugal. Two campaigns to collect water samples were performed in order to measure PAH levels. Fifteen of 16 studied PAH were found in groundwater samples collected at burned areas, most of them at concentrations significantly higher than those found in control regions, indicating aquifer contamination. The total sum of PAH in burned areas ranged from 23.1to 95.1 ng/L with a median of 62.9 ng/L, which is one- to sixfold higher than the average level measured in controls (16.2 ng/L). In addition, in control samples, the levels of light PAH with two to four rings were at higher levels than heavy PAH with five or six rings, thus showing a different profile between control and burned sites. The contribution of wildfires to groundwater contamination by PAH was demonstrated, enabling a reliable assessment of the impacts on water quality and preparation of scientifically based decision criteria for postfire forest management practices.

  4. Coxsackievirus B4 as a Causative Agent of Diabetes Mellitus Type 1: Is There a Role of Inefficiently Treated Drinking Water and Sewage in Virus Spreading?

    PubMed

    El-Senousy, Waled M; Abdel-Moneim, Adel; Abdel-Latif, Mahmoud; El-Hefnawy, Mohamed H; Khalil, Rehab G

    2018-03-01

    This study proposed to detect the enterovirus (EV) infection in children with type 1 diabetes mellitus (T1D) and to assess the role of insufficiently treated water and sewage as sources of viral spreading. Three hundred and eighty-two serum specimens of children with T1D, one hundred serum specimens of children who did not suffer from T1D as control, and forty-eight water and sewage samples were screened for EV RNA using nested RT-PCR. The number of genome copies and infectious units of EVs in raw and treated sewage and water samples were investigated using real-time (RT)-PCR and plaque assay, respectively. T1D markers [Fasting blood glucose (FBG), HbA1c, and C-peptide], in addition to anti-Coxsackie A & B viruses (CVs A & B) IgG, were measured in control, T1D-negative EV (T1D-EV - ), and T1D-positive EV (T1D-EV + ) children specimens. The prevalence of EV genome was significantly higher in diabetic children (26.2%, 100 out of 382) than the control children (0%, 0 out of 100). FBG and HbA1c in T1D-EV - and T1D-EV + children specimens were significantly higher than those in the control group, while c-peptide in T1D-EV - and T1D-EV + children specimens was significantly lower than that in the control (n = 100; p < 0.001). Positivity of anti-CVs A & B IgG was 70.7, 6.7, and 22.9% in T1D-EV + , T1D-EV - , and control children specimens, respectively. The prevalence of EV genome in drinking water and treated sewage samples was 25 and 33.3%, respectively. The prevalence of EV infectious units in drinking water and treated sewage samples was 8.5 and 25%, respectively. Quantification assays were performed to assess the capabilities of both wastewater treatment plants (WWTPs) and water treatment plants (WTPs) to remove EV. The reduction of EV genome in Zenin WWTP ranged from 2 to 4 log 10 , while the reduction of EV infectious units ranged from 1 to 4 log 10 . The reduction of EV genome in El-Giza WTP ranged from 1 to 3 log 10 , while the reduction of EV infectious units ranged from 1 to 2 log 10 . This capability of reduction did not prevent the appearance of infectious EV in treated sewage and drinking water. Plaque purification was performed for isolation of separate EV isolates from treated and untreated water and sewage samples. Characterization of the EV amplicons by RT-PCR followed by sequencing of these isolates revealed high homology (97%) with human coxsackievirus B4 (CV B4) in 60% of the isolates, while the rest of the isolates belonged to poliovirus type 1 and type 2 vaccine strains. On the other hand, characterization of the EV amplicons by RT-PCR followed by sequencing for T1D-EV + children specimens indicated that all samples contained CV B4 with the same sequence characterized in the environmental samples. CV B4-contaminated drinking water or treated sewage may play a role as a causative agent of T1D in children.

  5. Water quality of stormwater generated from an airport in a cold climate, function of an infiltration pond, and sampling strategy with limited resources.

    PubMed

    Jia, Yu; Ehlert, Ludwig; Wahlskog, Cecilia; Lundberg, Angela; Maurice, Christian

    2017-12-05

    Monitoring pollutants in stormwater discharge in cold climates is challenging. An environmental survey was performed by sampling the stormwater from Luleå Airport, Northern Sweden, during the period 2010-2013, when urea was used as a main component of aircraft deicing/anti-icing fluids (ADAFs). The stormwater collected from the runway was led through an oil trap to an infiltration pond to store excess water during precipitation periods and enhance infiltration and water treatment. Due to insufficient capacity, an emergency spillway was established and equipped with a flow meter and an automatic sampler. This study proposes a program for effective monitoring of pollutant discharge with a minimum number of sampling occasions when use of automatic samplers is not possible. The results showed that 90% of nitrogen discharge occurs during late autumn before the water pipes freeze and during snow melting, regardless of the precipitation during the remaining months when the pollutant discharge was negligible. The concentrations of other constituents in the discharge were generally low compared to guideline values. The best data quality was obtained using flow controlled sampling. Intensive time-controlled sampling during late autumn (few weeks) and snow melting (2 weeks) would be sufficient for necessary information. The flow meters installed at the rectangular notch appeared to be difficult to calibrate and gave contradictory results. Overall, the spillway was dry, as water infiltrated into the pond, and stagnant water close to the edge might be registered as flow. Water level monitoring revealed that the infiltration capacity gradually decreased with time.

  6. Food and drinking water hygiene and intestinal protozoa in deployed German soldiers.

    PubMed

    Frickmann, Hagen; Schwarz, Norbert G; Wiemer, Dorothea F; Fischer, Marcellus; Tannich, Egbert; Scheid, Patrick L; Müller, Martin; Schotte, Ulrich; Bock, Wolfgang; Hagen, Ralf M

    2013-03-01

    This report analyzes the occurrence of Cryptosporidium spp., E. histolytica, and G. intestinalis in stool of returnees from military deployments and the impact of hygiene precautions. Between 2007 and 2010, stool samples of 830 returnees that were obtained 8-12 weeks after military deployments in Afghanistan, Uzbekistan, the Balkans, Democratic Republic of the Congo/Gabonese Republic, and Sudan and 292 control samples from non-deployed soldiers were analyzed by PCR for Cryptosporidium spp., E. histolytica, G. intestinalis, and the commensal indicator of fecal contamination E. dispar. Data on hygiene precautions were available. The soldiers were questioned regarding gastrointestinal and general symptoms. Among 1122 stool samples, 18 were positive for G. intestinalis, 10 for E. dispar, and no-one for Cryptosporidium spp. and E. histolytica. An increased risk of acquiring chronic parasitic infections in comparison with non-deployed controls was demonstrated only for G. intestinalis in Sudan, where standardized food and drinking water hygiene precautions could not be implemented. Standard food and drinking water hygiene precautions in the context of screened military field camps proved to be highly reliable in preventing food-borne and water-borne chronic infections and colonization by intestinal protozoa, leading to detection proportions similar to those in non-deployed controls.

  7. Outbreak of legionnaires' disease from a cooling water system in a power station.

    PubMed

    Morton, S; Bartlett, C L; Bibby, L F; Hutchinson, D N; Dyer, J V; Dennis, P J

    1986-09-01

    In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positive serology. In a case control study it was found that cases of pneumonia were more likely than controls to have worked on a part of the site where four small capacity cooling towers were located. Legionella pneumophila serogroup 1 was isolated from the water systems of these four towers but was not found in samples from any other cooling towers or hot or cold water outlets on the site. It would appear that there was airborne spread of the organism from these cooling water systems which had not received conventional treatment to inhibit corrosion and organic growth. This is the first outbreak of legionnaires' disease to be recorded in an industrial setting in the United Kingdom. No cases of legionella infection have occurred on the site since the introduction of control measures.

  8. Influences of sample interference and interference controls on quantification of enterococci fecal indicator bacteria in surface water samples by the qPCR method

    EPA Science Inventory

    A quantitative polymerase chain reaction (qPCR) method for the detection of entercocci fecal indicator bacteria has been shown to be generally applicable for the analysis of temperate fresh (Great Lakes) and marine coastal waters and for providing risk-based determinations of wat...

  9. Use of copper-silver ionization for the control of legionellae in alkaline environments at health care facilities.

    PubMed

    Dziewulski, David M; Ingles, Erin; Codru, Neculai; Strepelis, John; Schoonmaker-Bopp, Dianna

    2015-09-01

    There are multiple treatment options for the control of legionellae in premise hot water systems. Water chemistry plays a role in the efficacy of these treatments and should be considered when selecting a treatment. This study demonstrated the efficacy of copper-silver ionization (CSI) under alkaline water conditions in 2 health care facilities. Monitoring for copper (Cu) and silver (Ag) ions was performed, and the corresponding percentage of positive Legionella cultures was monitored. Low Legionella colony forming units (CFU), with a mean <10 CFU/100 mL, and ≤30% positive culture for each sampling period, along with no recurrent disease, were considered indicative of control. CSI treatment was shown to reduce both the number of CFU found and the percentage of samples found to be culture positive. After treatment was established, culture positivity was, for example, reduced from 70% (>10(3) CFU/100 mL) to consistently <30% (38 CFU/100 mL). Control of legionellae in premise water systems may be a complex process requiring long-term assessments for adequate control. This work found that CSI could be successful in controlling Legionella under alkaline water conditions, and the evidence suggests that Ag ions are responsible for the control of Legionella pneumophila 1, L pneumophila 6, and L anisa. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. CRUMP 2003 Selected Water Sample Results

    EPA Pesticide Factsheets

    Point locations and water sampling results performed in 2003 by the Church Rock Uranium Monitoring Project (CRUMP) a consortium of organizations (Navajo Nation Environmental Protection Agency, US Environmental Protection Agency, New Mexico Scientific Laboratory Division, Navajo Tribal Utility Authority and NM Water Quality Control Commission). Samples include general description of the wells sampled, general chemistry, heavy metals and aestheic parameters, and selected radionuclides. Here only six sampling results are presented in this point shapefile, including: Gross Alpha (U-Nat Ref.) (pCi/L), Gross Beta (Sr/Y-90 Ref.) (pCi/L), Radium-226 (pCi/L), Radium-228 (pCi/L), Total Uranium (pCi/L), and Uranium mass (ug/L). The CRUMP samples were collected in the area of Churchrock, NM in the Eastern AUM Region of the Navajo Nation.

  11. In situ study of live specimens in an environmental scanning electron microscope.

    PubMed

    Tihlaříková, Eva; Neděla, Vilém; Shiojiri, Makoto

    2013-08-01

    In this paper we introduce new methodology for the observation of living biological samples in an environmental scanning electron microscope (ESEM). The methodology is based on an unconventional initiation procedure for ESEM chamber pumping, free from purge-flood cycles, and on the ability to control thermodynamic processes close to the sample. The gradual and gentle change of the working environment from air to water vapor enables the study of not only living samples in dynamic in situ experiments and their manifestation of life (sample walking) but also its experimentally stimulated physiological reactions. Moreover, Monte Carlo simulations of primary electron beam energy losses in a water layer on the sample surface were studied; consequently, the influence of the water thickness on radiation, temperature, or chemical damage of the sample was considered.

  12. Microbial biofilm studies of the Environmental Control and Life Support System water recovery test for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Obenhuber, D. C.; Huff, T. L.; Rodgers, E. B.

    1991-01-01

    Analysis of biofilm accumulation, studies of iodine disinfection of biofilm, and the potential for microbially influenced corrosion in the water recovery test (WRT) are presented. The analysis of WRT components showed the presence of biofilms and organic deposits in selected tubing. Water samples from the WRT contained sulfate-reducing and acid-producing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples, but stainless steel corrosion rates were not accelerated.

  13. Cassette bacteria detection system. [for monitoring the sterility of regenerated water in spacecraft

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The design, fabrication, and testing of an automatic bacteria detection system, with a zero-g capability, based on the filter-capable approach, and intended for monitoring the sterility of regenerated water in spacecraft is discussed. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. High signals for the incubated water sample indicate the presence of viable organisms.

  14. Planetary protection on international waters: An onboard protocol for capsule retrieval and biosafety control in sample return mission

    NASA Astrophysics Data System (ADS)

    Takano, Yoshinori; Yano, Hajime; Sekine, Yasuhito; Funase, Ryu; Takai, Ken

    2014-04-01

    Planetary protection has been recognized as one of the most important issues in sample return missions that may host certain living forms and biotic signatures in a returned sample. This paper proposes an initiative of sample capsule retrieval and onboard biosafety protocol in international waters for future biological and organic constituent missions to bring samples from possible habitable bodies in the solar system. We suggest the advantages of international waters being outside of national jurisdiction and active regions of human and traffic affairs on the condition that we accept the Outer Space Treaty. The scheme of onboard biological quarantine definitely reduces the potential risk of back-contamination of extraterrestrial materials to the Earth.

  15. Direct fabrication of gas diffusion cathode by pulse electrodeposition for proton exchange membrane water electrolysis

    NASA Astrophysics Data System (ADS)

    Park, Hyanjoo; Choe, Seunghoe; Kim, Hoyoung; Kim, Dong-Kwon; Cho, GeonHee; Park, YoonSu; Jang, Jong Hyun; Ha, Don-Hyung; Ahn, Sang Hyun; Kim, Soo-Kil

    2018-06-01

    Pt catalysts for water electrolysis were prepared on carbon paper by using both direct current and pulse electrodeposition. Controlling the mass transfer of Pt precursor in the electrolyte by varying the deposition potential enables the formation of various Pt particle shapes such as flower-like and polyhedral particles. Further control of the deposition parameters for pulse electrodeposition resulted in changes to the particle size and density. In particular, the upper potential of pulse was found to be the critical parameter controlling the morphology of the particles and their catalytic activity. In addition to the typical electrochemical measurements, Pt samples deposited on carbon paper were used as cathodes for a proton exchange membrane water electrolyser. This single cell test revealed that our Pt particle samples have exceptional mass activity while being cost effective.

  16. Controlling suspended samplers by programmable calculator and interface circuitry

    Treesearch

    Rand E. Eads; Mark R. Boolootian

    1985-01-01

    A programmable calculator connected to an interface circuit can control automatic samplers and record streamflow data. The circuit converts a voltage representing water stage to a digital signal. The sampling program logs streamflow data when there is a predefined deviation from a linear trend in the water elevation. The calculator estimates suspended sediment...

  17. Controlling suspended sediment samplers by programmable calculator and interface circuitry

    Treesearch

    Rand E. Eads; Mark R. Boolootian

    1985-01-01

    A programmable calculator connected to an interface circuit can control automatic samplers and record streamflow data. The circuit converts a voltage representing water stage to a digital signal. The sampling program logs streamflow data when there is a predefined deviation from a linear trend in the water elevation. The calculator estimates suspended sediment...

  18. Performance of the goulden large-sample extractor in multiclass pesticide isolation and preconcentration from stream water

    USGS Publications Warehouse

    Foster, G.D.; Foreman, W.T.; Gates, Paul M.

    1991-01-01

    The reliability of the Goulden large-sample extractor in preconcentrating pesticides from water was evaluated from the recoveries of 35 pesticides amended to filtered stream waters. Recoveries greater than 90% were observed for many of the pesticides in each major chemical class, but recoveries for some of the individual pesticides varied in seemingly unpredictable ways. Corrections cannot yet be factored into liquid-liquid extraction theory to account for matrix effects, which were apparent between the two stream waters tested. The Goulden large-sample extractor appears to be well suited for rapid chemical screening applications, with quantitative analysis requiring special quality control considerations. ?? 1991 American Chemical Society.

  19. Determination of small quantities of fluoride in water: A modified zirconium-alizarin method

    USGS Publications Warehouse

    Lamar, W.L.; Seegmiller, C.G.

    1941-01-01

    The zirconium-alizarin method has been modified to facilitate the convenient and accurate determination of small amounts of fluoride in a large number of water samples. Sulfuric acid is used to acidify the samples to reduce the interference of sulfate. The pH is accurately controlled to give the most sensitive comparisons. Most natural waters can be analyzed by the modified procedure without resorting to correction curves. The fluoride content of waters containing less than 500 parts per million of sulfate, 500 parts per million of bicarbonate, and 1000 parts per million of chloride may be determined within a limit of about 0.1 part per million when a 100-ml. sample is used.

  20. Correlation of lithium levels between drinking water obtained from different sources and scalp hair samples of adult male subjects.

    PubMed

    Baloch, Shahnawaz; Kazi, Tasneem Gul; Afridi, Hassan Imran; Baig, Jameel Ahmed; Talpur, Farah Naz; Arain, Muhammad Balal

    2017-10-01

    There is some evidence that natural levels of lithium (Li) in drinking water may have a protective effect on neurological health. In present study, we evaluate the Li levels in drinking water of different origin and bottled mineral water. To evaluate the association between lithium levels in drinking water with human health, the scalp hair samples of male subjects (25-45 years) consumed drinking water obtained from ground water (GW), municipal treated water (MTW) and bottled mineral water (BMW) from rural and urban areas of Sindh, Pakistan were selected. The water samples were pre-concentrated five to tenfold at 60 °C using temperature-controlled electric hot plate. While scalp hair samples were oxidized by acid in a microwave oven, prior to determined by flame atomic absorption spectrometry. The Li content in different types of drinking water, GW, MTW and BMW was found in the range of 5.12-22.6, 4.2-16.7 and 0.0-16.3 µg/L, respectively. It was observed that Li concentration in the scalp hair samples of adult males consuming ground water was found to be higher, ranged as 292-393 μg/kg, than those who are drinking municipal treated and bottle mineral water (212-268 and 145-208 μg/kg), respectively.

  1. Tularaemia outbreaks in Sakarya, Turkey: case-control and environmental studies.

    PubMed

    Meric, M; Sayan, M; Dundar, D; Willke, A

    2010-08-01

    Tularaemia is an important zoonotic disease that leads to outbreaks. This study aimed to compare the epidemiological characteristics of two tularaemia outbreaks that occurred in the Sakarya region of Turkey, analyse the risk factors for the development of outbreaks and identify Francisella (F.) tularensis in the water samples. Two tularaemia outbreaks occurred in the Kocadongel village in 2005 and 2006. A field investigation and a case-control study with 47 cases and 47 healthy households were performed during the second outbreak. Clinical samples from the patients and filtrated water samples were analysed for F. tularensis via real-time polymerase chain reaction. From the two outbreaks, a total of 58 patients were diagnosed with oropharyngeal tularaemia based on their clinical and serological results. Both outbreaks occurred between the months of January and April, and the number of patients peaked in February. Logistic regression analysis revealed that the consumption of natural spring water was the only significant risk factor for tularaemia infection (odds ratio 3.5, confidence interval 1.23-10.07). F. tularensis was detected in eight clinical samples and in the filtrated natural spring water. This study is the first report of tularaemia from this region. The results show that both tularaemia outbreaks were related to the consumption of untreated natural spring water. To prevent waterborne tularaemia, community water supplies should be treated and checked periodically.

  2. Estimating virus occurrence using Bayesian modeling in multiple drinking water systems of the United States.

    PubMed

    Varughese, Eunice A; Brinkman, Nichole E; Anneken, Emily M; Cashdollar, Jennifer L; Fout, G Shay; Furlong, Edward T; Kolpin, Dana W; Glassmeyer, Susan T; Keely, Scott P

    2018-04-01

    Drinking water treatment plants rely on purification of contaminated source waters to provide communities with potable water. One group of possible contaminants are enteric viruses. Measurement of viral quantities in environmental water systems are often performed using polymerase chain reaction (PCR) or quantitative PCR (qPCR). However, true values may be underestimated due to challenges involved in a multi-step viral concentration process and due to PCR inhibition. In this study, water samples were concentrated from 25 drinking water treatment plants (DWTPs) across the US to study the occurrence of enteric viruses in source water and removal after treatment. The five different types of viruses studied were adenovirus, norovirus GI, norovirus GII, enterovirus, and polyomavirus. Quantitative PCR was performed on all samples to determine presence or absence of these viruses in each sample. Ten DWTPs showed presence of one or more viruses in source water, with four DWTPs having treated drinking water testing positive. Furthermore, PCR inhibition was assessed for each sample using an exogenous amplification control, which indicated that all of the DWTP samples, including source and treated water samples, had some level of inhibition, confirming that inhibition plays an important role in PCR-based assessments of environmental samples. PCR inhibition measurements, viral recovery, and other assessments were incorporated into a Bayesian model to more accurately determine viral load in both source and treated water. Results of the Bayesian model indicated that viruses are present in source water and treated water. By using a Bayesian framework that incorporates inhibition, as well as many other parameters that affect viral detection, this study offers an approach for more accurately estimating the occurrence of viral pathogens in environmental waters. Published by Elsevier B.V.

  3. Ground-Water Quality Data in the Central Eastside San Joaquin Basin 2006: Results from the California GAMA Program

    USGS Publications Warehouse

    Landon, Matthew K.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 1,695-square-mile Central Eastside study unit (CESJO) was investigated from March through June 2006 as part of the Statewide Basin Assessment Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the California State Water Resources Control Board (SWRCB) in collaboration with the U.S. Geological Survey (USGS) and the Lawrence Livermore National Laboratory (LLNL). The study was designed to provide a spatially unbiased assessment of raw ground-water quality within CESJO, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 78 wells in Merced and Stanislaus Counties. Fifty-eight of the 78 wells were selected using a randomized grid-based method to provide statistical representation of the study unit (grid wells). Twenty of the wells were selected to evaluate changes in water chemistry along selected lateral or vertical ground-water flow paths in the aquifer (flow-path wells). The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), gasoline oxygenates and their degradates, pesticides and pesticide degradates], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), and 1,2,3-trichloropropane (1,2,3-TCP)], inorganic constituents that can occur naturally [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, carbon-14, and uranium isotopes and stable isotopes of hydrogen, oxygen, nitrogen, sulfur, and carbon], and dissolved noble and other gases also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blanks, replicates, samples for matrix spikes) were collected for approximately one-sixth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control results showed that the environmental data were of good quality, with low bias and low variability, and resulted in censoring of less than 0.3 percent of the detections found in ground-water samples. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CADPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CADPH. VOCs and pesticides were detected in approximately half of the grid wells, and all detections in samples from CESJO wells were below health-based thresholds. All detections of nutrients and major elements in grid wells also were below health-based thresholds. Most detections of constituents of special interest, trace elements, and radioactive constituents in samples from grid wells were below health-based thresholds. Exceptions included two detections of arsenic that were above the USEPA maximum contaminant level (MCL-US), one detection of lead above the USEPA action level (AL-US), and one detection of vanadium and three detections of 1,2,3-TCP that were above the CADPH notification levels (NL-CA). All detections of radioactive constituents were below health-based thresholds, although fourteen samples had activities of radon-222 above the lower proposed MCL-US. Most of th

  4. Sensor node for remote monitoring of waterborne disease-causing bacteria.

    PubMed

    Kim, Kyukwang; Myung, Hyun

    2015-05-05

    A sensor node for sampling water and checking for the presence of harmful bacteria such as E. coli in water sources was developed in this research. A chromogenic enzyme substrate assay method was used to easily detect coliform bacteria by monitoring the color change of the sampled water mixed with a reagent. Live webcam image streaming to the web browser of the end user with a Wi-Fi connected sensor node shows the water color changes in real time. The liquid can be manipulated on the web-based user interface, and also can be observed by webcam feeds. Image streaming and web console servers run on an embedded processor with an expansion board. The UART channel of the expansion board is connected to an external Arduino board and a motor driver to control self-priming water pumps to sample the water, mix the reagent, and remove the water sample after the test is completed. The sensor node can repeat water testing until the test reagent is depleted. The authors anticipate that the use of the sensor node developed in this research can decrease the cost and required labor for testing samples in a factory environment and checking the water quality of local water sources in developing countries.

  5. Geochemistry of ground water in the Gallup, Dakota, and Morrison aquifers, San Juan Basin, New Mexico

    USGS Publications Warehouse

    Dam, W.L.

    1995-01-01

    Ground water was sampled from wells completed in the Gallup, Dakota, and Morrison aquifers in the San Juan Basin, New Mexico, to examine controls on solute concentrations. Samples were collected from 38 wells primarily from the Morrison aquifer (25 wells) in the northwestern part of the basin. A series of samples was collected along ground-water flow paths; dissolved constituents varied horizontally and vertically. The understanding of the flow system changed as a result of the geochemical analyses. The conceptual model of the flow system in the Morrison aquifer prior to the study reported here assumed the Westwater Canyon Member of the Morrison aquifer as the only significant regional aquifer; flow was assumed to be two dimensional; and vertical leakage was assumed to be negligible. The geochemical results indicate that the Westwater Canyon Member is not the only major water-yielding zone and that the flow system is three dimensional. The data presented in this report suggest an upward component of flow into the Morrison aquifer. The entire section above and below the Morrison aquifer appears to be controlled by a three-dimensional flow regime where saline brine leaks near the San Juan River discharge area. Predominant ions in the Gallup aquifer were calcium bicarbonate in recharge areas and sodium sulfate in discharge areas. In the Dakota aquifer, predominant ions were sodium bicarbonate and sodium sulfate. Water in the Morrison aquifer was predominantly sodium bicarbonate in the recharge area, changing to sodium sulfate downgradient. Chemical and radioisotopic data indicate that water from overlying and underlying units mixes with recharge water in the Morrison aquifer. Recharge water contained a large ratio of chlorine-36 to chlorine and a small ratio of bromide to chloride. Approximately 10 miles downgradient, samples from four wells completed in the Morrison aquifer were considerably different in composition compared to recharge samples. Oxygen stable isotopes decreased by 2.8 per mil and deuterium decreased 26 per mil, relative to recharge. Carbon-14 radioisotope activities were not detectable. Chloride-36 radioisotope ratios were small and bromide to chloride concentration ratios were large. These results suggest two potentially viable processes: ion filtration or trapping of ancient dilute water recharged under a humid climate. For water samples near the San Juan River, pH decreased to about 8.0, chloride concentrations increased to more than 100 milligrams per liter, and ratios of chlorine-36 to chlorine and bromide to chloride were small. Leakage of deep basin brine into the fresher water of the Morrison aquifer appears to control ion concentrations.

  6. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    NASA Astrophysics Data System (ADS)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to < 50 μm, and < 10 μm. Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  7. Ground-Water Quality Data in the Central Sierra Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Ferrari, Matthew J.; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 950 square kilometer (370 square mile) Central Sierra study unit (CENSIE) was investigated in May 2006 as part of the Priority Basin Assessment project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment project was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). This study was designed to provide a spatially unbiased assessment of the quality of raw ground water used for drinking-water supplies within CENSIE, and to facilitate statistically consistent comparisons of ground-water quality throughout California. Samples were collected from thirty wells in Madera County. Twenty-seven of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and three were selected to aid in evaluation of specific water-quality issues (understanding wells). Ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates), constituents of special interest (N-nitrosodimethylamine, perchlorate, and 1,2,3-trichloropropane), naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon], and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 250 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-sixth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Results from field blanks indicated contamination was not a noticeable source of bias in the data for ground-water samples. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most constituents. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and thresholds established for aesthetic concerns (Secondary Maximum Contaminant Levels, SMCL-CA) by CDPH. Therefore, any comparisons of the results of this study to drinking-water standards only is for illustrative purposes and is not indicative of compliance or non-compliance to those standards. Most constituents that were detected in ground-water samples were found at concentrations below drinking-water standards or thresholds. Six constituents? fluoride, arsenic, molybdenum, uranium, gross-alpha radioactivity, and radon-222?were detected at concentrations higher than thresholds set for health-based regulatory purposes. Three additional constituents?pH, iron and manganese?were detected at concentrations above thresholds set for aesthetic concerns. Volatile organic compounds (VOCs) and pesticides, were detected in less than one-third of the samples and generally at less than one one-hundredth of a health-based threshold.

  8. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    PubMed Central

    2010-01-01

    Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003

  9. Controls on surface water chemistry in the upper Merced River basin, Yosemite National Park, California

    USGS Publications Warehouse

    Clow, D.W.; Mast, M.A.; Campbell, D.H.

    1996-01-01

    Surface water draining granitic bedrock in Yosemite National Park exhibits considerable variability in chemical composition, despite the relative homogeneity of bedrock chemistry. Other geological factors, including the jointing and distribution of glacial till, appear to exert strong controls on water composition. Chemical data from three surface water surveys in the upper Merced River basin conducted in August 1981, June 1988 and August 1991 were analysed and compared with mapped geological, hydrological and topographic features to identify the solute sources and processes that control water chemistry within the basin during baseflow. Water at most of the sampling sites was dilute, with alkalinities ranging from 26 to 77 ??equiv. 1-1. Alkalinity was much higher in two subcatchments, however, ranging from 51 to 302 ??equiv. 1-1. Base cations and silica were also significantly higher in these two catchments than in the rest of the watershed. Concentrations of weathering products in surface water were correlated to the fraction of each subcatchment underlain by surficial material, which is mostly glacial till. Silicate mineral weathering is the dominant control on concentrations of alkalinity, silica and base cations, and ratios of these constituents in surface water reflect the composition of local bedrock, Chloride concentrations in surface water samples varied widely, ranging from <1 to 96 ??equiv. 1-1. The annual volume-weighted mean chloride concentration in the Merced River at the Happy Isles gauge from 1968 to 1990 was 26 ??equiv. 1-1, which was five times higher than in atmospheric deposition (4-5 ??equiv. 1-1), suggesting that a source of chloride exists within the watershed. Saline groundwater springs, whose locations are probably controlled by vertical jointing in the bedrock, are the most likely source of the chloride. Sulphate concentrations varied much less than most other solutes, ranging from 3 to 14 ??equiv. 1-1. Concentrations of sulphate in quarterly samples collected at the watershed outlet also showed relatively little variation, suggesting that sulphate may be regulated to some extent by a within-watershed process, such as sulphate adsorption.

  10. Geochemical appraisal of fluoride-laden groundwater in Suri I and II blocks, Birbhum district, West Bengal

    NASA Astrophysics Data System (ADS)

    Das, Shreya; Nag, S. K.

    2017-09-01

    The present study has been carried out covering two blocks—Suri I and II in Birbhum district, West Bengal, India. The evaluation focuses on occurrence, distribution and geochemistry in 26 water samples collected from borewells spread across the entire study area homogeneously. Quantitative chemical analysis of groundwater samples collected from the present study area has shown that samples from two locations—Gangta and Dhalla contain fluoride greater than the permissible limit prescribed by WHO during both post-monsoon and pre-monsoon sampling sessions. Significant factor controlling geochemistry of groundwater has been identified to be rock-water interaction processes during both sampling sessions based on the results of Gibb's diagrams. Geochemical modeling studies have revealed that fluorite (CaF2) is, indeed, present as a significant fluoride-bearing mineral in the groundwaters of this study area. Calcite or CaCO3 is one of the most common minerals with which fluorite remains associated, and saturation index calculations have revealed that the calcite-fluorite geochemistry is the dominant factor controlling fluoride concentration in this area during both post- and pre-monsoon. High fluoride waters have also been found to be of `bicarbonate' type showing increase of sodium in water with decrease of calcium.

  11. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  12. Isolation of the etiological agent of primary amoebic meningoencephalitis from artificially heated waters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, A.R.; Tyndall, R.L.; Coutant, C.C.

    1977-12-01

    To determine whether artificial heating of water by power plant discharges facilitates proliferation of the pathogenic free-living amoebae that cause primary amoebic meningoencephalitis, water samples (250 ml) were taken from discharges within 3,000 feet (ca. 914.4 m) of power plants and were processed for amoeba culture. Pathogenic Naegleria fowleri grew out of water samples from two of five lakes and rivers in Florida and from one of eight man-made lakes in Texas. Pathogenic N. fowleri did not grow from water samples taken from cooling towers and control lakes, the latter of which had no associated power plants. The identification ofmore » N. fowleri was confirmed by pathogenicity in mice and by indirect immunofluorescence analyses, by using a specific antiserum.« less

  13. Water-Quality Data Collected from Vallecito Reservoir, Its Inflows and Outflow, Southwestern Colorado, 1999-2002

    USGS Publications Warehouse

    Ranalli, Anthony J.

    2008-01-01

    The Pine River Watershed Stakeholders Group was created in December 1997 to allow local participation in addressing water-quality issues in Los Pi?os River watershed, including Vallecito Reservoir in southwestern Colorado. One water-quality issue identified by the stakeholder group is to increase the understanding of the current water quality of Vallecito Reservoir, its two major inflows, and its outflow. The U.S. Geological Survey (USGS), in cooperation with volunteers from the Pine River Watershed Stakeholders Group and the U.S. Environmental Protection Agency (USEPA), U.S. Bureau of Reclamation (BOR), Colorado Department of Public Health and Environment (CDPHE), Pine River Irrigation District, Southern Ute Tribe, San Juan Basin Health Department, and San Juan Resource Conservation and Development, collected water-quality samples from Vallecito Reservoir, its two major inflows, and its outflow between August 1999 and November 2002 at about monthly intervals from April through November. The water-quality samples were analyzed for total and dissolved metals (aluminum, arsenic, cadmium, copper, chromium, iron, lead, manganese, mercury, nickel, silver, and zinc), dissolved major ions (calcium, magnesium, sodium, potassium, chloride, bicarbonate, and sulfate), dissolved silica, dissolved organic carbon (DOC), ultraviolet (UV) absorbance at 254 and 280 nanometers, nutrients (total organic nitrogen, dissolved organic nitrogen, dissolved ammonia, dissolved nitrate, total phosphorus, dissolved phosphorus, and orthophosphate), chlorophyll-a (reservoir only), and suspended sediment (inlets to the reservoir only). Measurements of field properties (pH, specific conductance, water temperature, and dissolved oxygen) were also made at each sampling site each time a water-quality sample was collected. This report documents (1) sampling sites and times of sample collection, (2) sample-collection methods, (3) laboratory analytical methods, and (4) responsibilities of each agency/group involved in the project. The report also provides the environmental and quality-control data collected during the project and provides an interpretation of the quality-control data (field blanks and field duplicates) to assess the quality of the environmental data. This report provides a baseline data set against which future changes in water quality can be assessed.

  14. Water quality assessment using the AREc32 reporter gene assay indicative of the oxidative stress response pathway.

    PubMed

    Escher, Beate I; Dutt, Mriga; Maylin, Erin; Tang, Janet Y M; Toze, Simon; Wolf, C Roland; Lang, Matti

    2012-11-01

    The reporter gene assay AREc32 is based on the induction of the Nrf2 mediated oxidative stress response pathway in the human breast cancer cell line MCF7, where eight copies of the antioxidant response element (ARE) are linked to a reporter gene encoding for luciferase. The Nrf2-ARE pathway is responsive to many chemicals that cause oxidative stress, among them a large number of pesticides and skin irritants. We adopted and validated the AREc32 bioassay for water quality testing. tert-Butylhydroquinone served as the positive control, phenol as the negative control and other reactive chemicals were assessed for their specificity. An environmentally relevant reference chemical, benzo(a)pyrene was the most potent inducer of all tested chemicals. The concentration causing an induction ratio (IR) of 1.5 (EC(IR1.5)) was chosen as the effect benchmark value. The assay was applied to 21 water samples ranging from sewage to drinking water, including secondary treatment and various tertiary treatment options (ozonation, biologically activated carbon filtration, membrane filtration, reverse osmosis, advanced oxidation, chlorination, chloramination). The samples were enriched by solid phase extraction. In most samples the oxidative stress response was far more sensitive than cytotoxicity. The primary and secondary treated effluent exceeded the effect threshold IR 1.5 at a relative enrichment factor (REF) of 1, i.e., the native samples were active. All tertiary treated samples were less potent and their EC(IR1.5) lay between REF 1 and 10. The Nrf2 pathway was induced at a REF of approximately 10 for surface waters and drinking water, and above this enrichment cytotoxicity took over in most samples and quenched the induction. The blank (ultrapure water run through the sample enrichment process) was cytotoxic at an REF of 100, which is the limit of concentrations range that can be evaluated. Treatment typically decreased both the cytotoxicity and oxidative stress response apart from drinking water treatment where chlorination caused an increase in oxidative stress response, presumably due to the formation of disinfection by-products. This study demonstrates the relevance and applicability of the oxidative stress response pathway for water quality monitoring.

  15. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to determine the quantity of each taxon present in the semi-quantitative samples or to list the taxa present in qualitative samples. The processing guidelines provide standardized laboratory forms, sample labels, detailed sample processing flow charts, standardized format for electronic data, quality-assurance procedures and checks, sample tracking standards, and target levels for taxonomic determinations. The contract laboratory (1) is responsible for identifications and quantifications, (2) constructs reference collections, (3) provides data in hard copy and electronic forms, (4) follows specified quality-assurance and quality-control procedures, and (5) returns all processed and unprocessed portions of the samples. The U.S. Geological Survey's Quality Management Group maintains a Biological Quality-Assurance Unit, located at the National Water-Quality Laboratory, Arvada, Colorado, to oversee the use of contract laboratories and ensure the quality of data obtained from these laboratories according to the guidelines established in this document. This unit establishes contract specifications, reviews contractor performance (timeliness, accuracy, and consistency), enters data into the National Water Information System-II data base, maintains in-house reference collections, deposits voucher specimens in outside museums, and interacts with taxonomic experts within and outside the U.S. Geological Survey. This unit also modifies the existing sample processing and quality-assurance guidelines, establishes criteria and testing procedures for qualifying potential contract laboratories, identifies qualified taxonomic experts, and establishes voucher collections.

  16. Total Water Content Measurements with an Isokinetic Sampling Probe

    NASA Technical Reports Server (NTRS)

    Reehorst, Andrew L.; Miller, Dean R.; Bidwell, Colin S.

    2010-01-01

    The NASA Glenn Research Center has developed a Total Water Content (TWC) Isokinetic Sampling Probe. Since it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument is comprised of the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Analysis and testing have been conducted on the subsystems to ensure their proper function and accuracy. End-to-end bench testing has also been conducted to ensure the reliability of the entire instrument system. A Stokes Number based collection efficiency correction was developed to correct for probe thickness effects. The authors further discuss the need to ensure that no condensation occurs within the instrument plumbing. Instrument measurements compared to facility calibrations from testing in the NASA Glenn Icing Research Tunnel are presented and discussed. There appears to be liquid water content and droplet size effects in the differences between the two measurement techniques.

  17. Expedition Six Flight Engineer Pettit uses a chemical/microbial analysis bag to collect water sample

    NASA Image and Video Library

    2002-12-18

    ISS006-E-08628 (18 December 2002) --- Astronaut Donald R. Pettit, Expedition Six NASA ISS science officer, is pictured in the Zvezda Service Module on the International Space Station (ISS) during the scheduled Week 3 potable water sampling and on-orbit chemical/microbial analysis of the SM environment control and life support system.

  18. Expedition Six Flight Engineer Pettit uses a chemical/microbial analysis bag to collect water sample

    NASA Image and Video Library

    2002-12-18

    ISS006-E-08616 (18 December 2002) --- Astronaut Donald R. Pettit, Expedition Six NASA ISS science officer, is pictured in the Zvezda Service Module on the International Space Station (ISS) during the scheduled Week 3 potable water sampling and on-orbit chemical/microbial analysis of the SM environment control and life support system.

  19. Photoacoustic monitoring of water transport process in calcareous stone coated with biopolymers

    NASA Astrophysics Data System (ADS)

    May-Crespo, J.; Ortega-Morales, B. O.; Camacho-Chab, J. C.; Quintana, P.; Alvarado-Gil, J. J.; Gonzalez-García, G.; Reyes-Estebanez, M.; Chan-Bacab, M. J.

    2016-12-01

    Moisture is a critical control of chemical and physical processes leading to stone deterioration. These processes can be enhanced by microbial biofilms and associated exopolymers (EPS). There is limited current understanding of the water transport process across rocks covered by EPS. In the present work, we employed the photoacoustic technique to study the influence of three biopolymers (xanthan, microbactan and arabic gum) in the water transport process of two types of limestone rock of similar mineralogy but contrasting porosity. Both controls of RL (low porosity) and RP (high porosity) presented the higher values of water diffusion coefficient ( D) than biopolymer-coated samples, indicating that biopolymer layers slowed down the transport of water. This trend was steeper for RP samples as water was transported seven times faster than in the more porous rock. Important differences of D values were observed among samples coated by different biopolymers. Scanning electron microscopy and optical microscopy showed that surface topography was different between both types of rocks; adherence of coatings was seen predominantly in the less porous rocks samples. FTIR and NMR analysis showed the presence of pyruvate and acetate in microbactan and xanthan gum, suggesting their participation on adherence to the calcareous surfaces, sealing surface pores. These results indicate that water transport at rock interfaces is dependent on the chemistry of biopolymer and surface porosity. The implications for reduced water transport in stone conservation under the influence of biopolymers include both enhanced and lower deterioration rates along with altered efficiency of biocide treatment of epilithic biofilms.

  20. An outbreak of norovirus-associated acute gastroenteritis associated with contaminated barrelled water in many schools in Zhejiang, China

    PubMed Central

    Sheng, Minyang; Song, Jianqiang; He, Fan; Qiu, Yinwei; Wu, Haocheng; Lu, Qinbao; Feng, Yan; Lin, Junfen; Chen, Enfu; Chai, Chengliang

    2017-01-01

    Objectives More than 900 students and teachers at many schools in Jiaxing city developed acute gastroenteritis in February 2014. An immediate epidemiological investigation was conducted to identify the pathogen, infection sources and route of transmission. Methods The probable cases and confirmed cases were defined as students or teachers with diarrhoea or vomiting present since the term began in February 2014. An active search was conducted for undiagnosed cases among students and teachers. Details such as demographic characteristics, gastrointestinal symptoms, and drinking water preference and frequency were collected via a uniform epidemiological questionnaire. A case-control study was implemented, and odds ratios (ORs) and 95% confidence intervals were calculated. Rectal swabs from several patients, food handlers and barrelled water factory workers, as well as water and food samples, were collected to test for potential bacteria and viruses. Results A total of 924 cases fit the definition of the probable case, including 8 cases of laboratory-confirmed norovirus infection at 13 schools in Jiaxing city between February 12 and February 21, 2014. The case-control study demonstrated that barrelled water was a risk factor (OR: 20.15, 95% CI: 2.59–156.76) and that bottled water and boiled barrelled water were protective factors (OR: 0.31, 95% CI: 0.13–0.70, and OR: 0.36, 95% CI: 0.16–0.77). A total of 11 rectal samples and 8 barrelled water samples were detected as norovirus-positive, and the genotypes of viral strains were the same (GII). The norovirus that contaminated the barrelled water largely came from the asymptomatic workers. Conclusions This acute gastroenteritis outbreak was caused by barrelled water contaminated by norovirus. The outbreak was controlled after stopping the supply of barrelled water. The barrelled water supply in China represents a potential source of acute gastroenteritis outbreaks due to the lack of surveillance and supervision. Therefore, more attention should be paid to this area. PMID:28170414

  1. An outbreak of norovirus-associated acute gastroenteritis associated with contaminated barrelled water in many schools in Zhejiang, China.

    PubMed

    Shang, Xiaopeng; Fu, Xiaofei; Zhang, Peng; Sheng, Minyang; Song, Jianqiang; He, Fan; Qiu, Yinwei; Wu, Haocheng; Lu, Qinbao; Feng, Yan; Lin, Junfen; Chen, Enfu; Chai, Chengliang

    2017-01-01

    More than 900 students and teachers at many schools in Jiaxing city developed acute gastroenteritis in February 2014. An immediate epidemiological investigation was conducted to identify the pathogen, infection sources and route of transmission. The probable cases and confirmed cases were defined as students or teachers with diarrhoea or vomiting present since the term began in February 2014. An active search was conducted for undiagnosed cases among students and teachers. Details such as demographic characteristics, gastrointestinal symptoms, and drinking water preference and frequency were collected via a uniform epidemiological questionnaire. A case-control study was implemented, and odds ratios (ORs) and 95% confidence intervals were calculated. Rectal swabs from several patients, food handlers and barrelled water factory workers, as well as water and food samples, were collected to test for potential bacteria and viruses. A total of 924 cases fit the definition of the probable case, including 8 cases of laboratory-confirmed norovirus infection at 13 schools in Jiaxing city between February 12 and February 21, 2014. The case-control study demonstrated that barrelled water was a risk factor (OR: 20.15, 95% CI: 2.59-156.76) and that bottled water and boiled barrelled water were protective factors (OR: 0.31, 95% CI: 0.13-0.70, and OR: 0.36, 95% CI: 0.16-0.77). A total of 11 rectal samples and 8 barrelled water samples were detected as norovirus-positive, and the genotypes of viral strains were the same (GII). The norovirus that contaminated the barrelled water largely came from the asymptomatic workers. This acute gastroenteritis outbreak was caused by barrelled water contaminated by norovirus. The outbreak was controlled after stopping the supply of barrelled water. The barrelled water supply in China represents a potential source of acute gastroenteritis outbreaks due to the lack of surveillance and supervision. Therefore, more attention should be paid to this area.

  2. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    PubMed

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  3. The bacteriological quality of different brands of bottled water available to consumers in Ile-Ife, south-western Nigeria.

    PubMed

    Igbeneghu, Oluwatoyin A; Lamikanra, Adebayo

    2014-11-28

    The upsurge in the demand for bottled water has prompted the interest of many manufacturers in the production of bottled water and very many water bottling companies are therefore involved in its production. These range from large scale multinational companies to medium scale business enterprises, institutional and government business investment companies as well as small scale entrepreneurs. There is however little information on the comparative quality of bottled water brands produced by different classes of water bottling companies in Nigeria. This study was undertaken to determine the bacteriological quality of brands of bottled water available to consumers in Ile-Ife. Forty-three samples of bottled water comprising of three batches each of thirteen bottled water brands and two batches of two brands were purchased and analyzed for total bacterial count, presence of coliform and the presence of other bacterial indicators of drinking water quality. Only 67.4% of the water samples representing the products of 10 companies or 66.7% of the brands had heterotrophic counts within the acceptable limits. Coliforms present in 100 ml of water were detected in 26.7% of the bottled water brands. Other indicator organisms detected included Staphylococci isolated from 27.9% of the samples (33.3% of the brands) and specifically Staphylococcus aureus found in four brands constituting 14% of the samples. Pseudomonas strains were consistently detected in consecutive batches of three brands of the water samples. Bottled water samples produced by the large scale multinational producers were of acceptable bacteriological quality unlike those produced by most small companies. There is need for a greater control of water bottling processes carried out by commercial bottled water producers in Nigeria.

  4. Effect of water chemistry upsets on the dynamics of corrective reagent dosing systems at thermal power stations

    NASA Astrophysics Data System (ADS)

    Voronov, V. N.; Yegoshina, O. V.; Bolshakova, N. A.; Yarovoi, V. O.; Latt, Aie Min

    2016-12-01

    Typical disturbances in the dynamics of a corrective reagent dosing system under unsteady-state conditions during the unsatisfactory operation of a chemical control system with some water chemistry upsets at thermal and nuclear power stations are considered. An experimental setup representing a physical model for the water chemistry control system is described. The two disturbances, which are most frequently encountered in water chemistry control practice, such as a breakdown or shutdown of temperature compensation during pH measurement and an increase in the heat-transfer fluid flow rate, have been modeled in the process of study. The study of the effect produced by the response characteristics of chemical control analyzers on the operation of a reagent dosing system under unsteady-state conditions is important for the operative control of a water chemistry regime state. The effect of temperature compensation during pH measurement on the dynamics of an ammonia-dosing system in the manual and automatic cycle chemistry control modes has been studied. It has been demonstrated that the reading settling time of a pH meter in the manual ammonia- dosing mode grows with a breakdown in temperature compensation and a simultaneous increase in the temperature of a heat-transfer fluid sample. To improve the efficiency of water chemistry control, some systems for the quality control of a heat-transfer fluid by a chemical parameter with the obligatory compensation of a disturbance in its flow rate have been proposed for use. Experimental results will possibly differ from industrial data due to a great length of sampling lines. For this reason, corrective reagent dosing systems must be adapted to the conditions of a certain power-generating unit in the process of their implementation.

  5. Graphene nanoplatelets as high-performance filtration control material in water-based drilling fluids

    NASA Astrophysics Data System (ADS)

    Ridha, Syahrir; Ibrahim, Arif; Shahari, Radzi; Fonna, Syarizal

    2018-05-01

    The main objective of this work is to evaluate the effectiveness of graphene nanoplatelets (GNP) as filtration control materials in water based drilling fluids. Three (3) general samples of water based drilling fluids were prepared including basic potassium chloride (KCl) drilling fluids, nanosilica (NS) drilling fluids and GNP drilling fluids. Several concentrations of NS and GNP were dispersed in controlled formulations of water based drilling fluids. Standard API filtration tests were carried out for comparison purposes as well as High Temperature High Pressure (HTHP) filtration tests at 150 °F (∼66 °C), 250 °F (∼121 °C) and 350 °F (∼177 °C) at a fixed 500 (∼3.45MPa) psi to study the filtration trend as a function of temperature. Mud cake samples from several tests were selectively chosen and analyzed under Field Emission Scanning Electron Microscope (FESEM) for its morphology. Results from this work show that nanoparticle concentrations play a factor in filtration ability of colloid materials in water based drilling fluids when studied at elevated temperature. Low temperature filtration, however, shows only small differences in volume in all the drilling fluid samples. 0.1 ppb concentrations of GNP reduced the fluid loss of 350 °F by 4.6 mL as compared to the similar concentration of NS drilling fluids.

  6. Water Quality and Geochemical Modeling of Water at an Abandoned Coal Mine Reclaimed With Coal Combustion By-Products

    USGS Publications Warehouse

    Haefner, Ralph J.

    2002-01-01

    An abandoned coal mine in eastern Ohio was reclaimed with 125 tons per acre of pressurized fluidized bed combustion (PFBC) by-product. Water quality at the site (known as the Fleming site) was monitored for 7 years after reclamation; samples included water from soil-suction lysimeters (interstitial water), wells, and spring sites established downgradient of the application area. This report presents a summary of data collected at the Fleming site during the period September 1994 through June 2001. Additionally, results of geochemical modeling are included in this report to evaluate the potential fate of elements derived from the PFBC by-product. Chemical analyses of samples of interstitial waters within the PFBC by-product application area indicated elevated levels of pH and specific conductance and elevated concentrations of boron, calcium, chloride, fluoride, magnesium, potassium, strontium, and sulfate compared to water samples collected in a control area where traditional reclamation methods were used. Magnesium-to-calcium (Mg:Ca) mole ratios and sulfur-isotope ratios were used to trace the PFBC by-product leachate and showed that little, if any, leachate reached ground water. Concentrations of most constituents in interstitial waters in the application-area decreased during the seven sampling rounds and approached background concentrations observed in the control area; however, median pH in the application area remained above 6, indicating that some acid-neutralizing capacity was still present. Although notable changes in water quality were observed in interstitial waters during the study period, quality of ground water and spring water remained poor. Water from the Fleming site was not potable, given exceedances of primary and secondary Maximum Contaminant Levels (MCLs) for inorganic constituents in drinking water set by the U.S. Environmental Protection Agency. Only fluoride and sulfate, which were found in higher concentrations in application-area interstitial waters than in control-area interstitial waters, could be related to the PFBC by-product. Concentrations of arsenic, lead, and selenium typically were at or below the detection limits (generally 1 or 2 micrograms per liter). Elements detected at elevated concentrations in PFBC by-product application-area interstitial waters were not evident in downgradient ground water or spring water. Dilution of leachate by ground water was confirmed with a mixing model generated by the computer code NETPATH. Additionally, thermodynamic modeling of the chemical composition of water samples by use of the computer code PHREEQC indicated favorable conditions for precipitation of secondary minerals in the unsaturated zone and in aquifer materials. Because of low application rates of PFBC by-product and precipitation and sorption of elements in the unsaturated zone, it is improbable that concentrations of any toxic elements of concern (arsenic, lead, or selenium) will exceed drinking-water standards at this site or other sites where similar volumes of PFBC by-products are used.

  7. Ground-Water Quality Data in the Coastal Los Angeles Basin Study Unit, 2006: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Land, Michael; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 860 square-mile Coastal Los Angeles Basin study unit (CLAB) was investigated from June to November of 2006 as part of the Statewide Basin Assessment Project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Coastal Los Angeles Basin study was designed to provide a spatially unbiased assessment of raw ground-water quality within CLAB, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 69 wells in Los Angeles and Orange Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (?grid wells?). Fourteen additional wells were selected to evaluate changes in ground-water chemistry or to gain a greater understanding of the ground-water quality within a specific portion of the Coastal Los Angeles Basin study unit ('understanding wells'). Ground-water samples were analyzed for: a large number of synthetic organic constituents [volatile organic compounds (VOCs), gasoline oxygenates and their degradates, pesticides, polar pesticides, and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicators]; constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,4-dioxane, and 1,2,3-trichloropropane (1,2,3-TCP)]; inorganic constituents that can occur naturally [nutrients, major and minor ions, and trace elements]; radioactive constituents [gross-alpha and gross-beta radiation, radium isotopes, and radon-222]; and microbial indicators. Naturally occurring isotopes [stable isotopic ratios of hydrogen and oxygen, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-fourth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compounds. Assessment of the quality-control information resulted in applying ?V? codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). This study did not attempt to evaluate the quality of drinking water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable drinking-water quality. Regulatory thresholds are applied to the treated drinking water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA), California Department of Public Health (CDPH, formerly California Department of Health Services [CADHS]) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. VOCs were detected in alm

  8. Detection of viable but non-culturable legionella in hospital water network following monochloramine disinfection.

    PubMed

    Casini, B; Baggiani, A; Totaro, M; Mansi, A; Costa, A L; Aquino, F; Miccoli, M; Valentini, P; Bruschi, F; Lopalco, P L; Privitera, G

    2018-01-01

    Prevention of legionellosis remains a critical issue in healthcare settings where monochloramine (MC) disinfection was recently introduced as an alternative to chlorine dioxide in controlling Legionella spp. contamination of the hospital water network. Continuous treatments with low MC doses in some instances have induced a viable but non-culturable state (VBNC) of Legionella spp. To investigate the occurrence of such dormant cells during a long period of continuous MC treatment. Between November 2010 and April 2015, 162 water and biofilm samples were collected and Legionella spp. isolated in accordance with standard procedures. In sampling sites where MC was <1.5mg/L, VBNC cells were investigated by ethidium monoazide bromide (EMA)-real-time polymerase chain reaction (qPCR) and 'resuscitation' test into Acanthamoeba polyphaga CCAP 1501/18. According to the Health Protection Agency protocol, free-living protozoa were researched in 60 five-litre water samples. In all, 136 out of 156 (87.2%) of the samples taken from sites previously positive for L. pneumophila ST269 were negative by culture, but only 47 (34.5%) negative by qPCR. Although no positive results were obtained by EMA-qPCR, four out of 22 samples associated with MC concentration of 1.3 ± 0.5mg/L showed VBNC legionella resuscitation. The presence of the amoeba A. polyphaga in the hospital water network was demonstrated. Our study is the first report evidencing the emergence of VNBC legionella during a long period of continuous MC treatment of a hospital water network, highlighting the importance of keeping an appropriate and uninterrupted MC dosage to ensure the control of legionella colonization in hospital water supplies. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. THE EMPACT BEACHES PROJECT - A STUDY OF THE PARAMETERS THAT AFFECT MICROBIOLOGICAL MONITORING

    EPA Science Inventory

    The current U. S. Environmental Protection Agency (EPA) water sample collection method for recreational water was suggested by the Federal Water Pollution Control Agency in 1968 as part of the fecal coliform guideline. Although improvements have been made in the indicator bacter...

  10. Legionella prevalence and risk of legionellosis in Japanese households.

    PubMed

    Kuroki, T; Watanabe, Y; Teranishi, H; Izumiyama, S; Amemura-Maekawa, J; Kura, F

    2017-05-01

    This study determined the occurrence of legionellae in private houses for which there were no available data on aquatic environments other than the water supply system. From June 2013 to November 2014, we collected 138 water and 90 swab samples from aquatic environments in 19 houses. Legionella DNA was detected via a loop-mediated isothermal amplification assay in 66 (47·8%) water and 17 (18·9%) swab samples. High Legionella DNA detection rates were observed in water samples from washing machines and aquariums. Legionella spp. was isolated from 9 (6·5%) water and 3 (3·3%) swab samples. Legionella pneumophila SG 1 was detected from the outlet water of a bathtub spout and a bath sponge. Use of amoebic co-culture effectively increased legionellae and Legionella DNA detection rates from all sample types. A logistic regression analysis revealed that the heterotrophic plate count was significantly related to Legionella contamination. Our findings indicate that there is a risk of legionellosis from exposure to Legionella spp. in a variety of aquatic environments in residential houses. Control measures for legionellae in houses should include frequent cleaning and disinfecting to reduce heterotrophic bacteria in water and, where possible, preventing aerosolization from aquatic environments.

  11. Legionella spp. in dental unit waterlines.

    PubMed

    Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I

    2017-01-01

    To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).

  12. Calibration of silicone rubber rods as passive samplers for pesticides at two different flow velocities: Modeling of sampling rates under water boundary layer and polymer control.

    PubMed

    Martin, Alexis; Margoum, Christelle; Jolivet, Antoine; Assoumani, Azziz; El Moujahid, Bachir; Randon, Jérôme; Coquery, Marina

    2018-04-01

    There is a need to determine time-weighted average concentrations of polar contaminants such as pesticides by passive sampling in environmental waters. Calibration data for silicone rubber-based passive samplers are lacking for this class of compounds. The calibration data, sampling rate (R s ), and partition coefficient between silicone rubber and water (K sw ) were precisely determined for 23 pesticides and 13 candidate performance reference compounds (PRCs) in a laboratory calibration system over 14 d for 2 water flow velocities, 5 and 20 cm s -1 . The results showed that an in situ exposure duration of 7 d left a silicone rubber rod passive sampler configuration in the linear or curvilinear uptake period for 19 of the pesticides studied. A change in the transport mechanism from polymer control to water boundary layer control was observed for pesticides with a log K sw of approximately 3.3. The PRC candidates were not fully relevant to correct the impact of water flow velocity on R s . We therefore propose an alternative method based on an overall resistance to mass transfer model to adjust R s from laboratory experiments to in situ hydrodynamic conditions. We estimated diffusion coefficients (D s ) and thickness of water boundary layer (δ w ) as adjustable model parameters. Log D s values ranged from -12.13 to -10.07 m 2  s -1 . The estimated δ w value showed a power function correlation with water flow velocity. Environ Toxicol Chem 2018;37:1208-1218. © 2017 SETAC. © 2017 SETAC.

  13. Multi-laboratory survey of qPCR enterococci analysis method performance

    EPA Pesticide Factsheets

    Quantitative polymerase chain reaction (qPCR) has become a frequently used technique for quantifying enterococci in recreational surface waters, but there are several methodological options. Here we evaluated how three method permutations, type of mastermix, sample extract dilution and use of controls in results calculation, affect method reliability among multiple laboratories with respect to sample interference. Multiple samples from each of 22 sites representing an array of habitat types were analyzed using EPA Method 1611 and 1609 reagents with full strength and five-fold diluted extracts. The presence of interference was assessed three ways: using sample processing and PCR amplifications controls; consistency of results across extract dilutions; and relative recovery of target genes from spiked enterococci in water sample compared to control matrices with acceptable recovery defined as 50 to 200%. Method 1609, which is based on an environmental mastermix, was found to be superior to Method 1611, which is based on a universal mastermix. Method 1611 had over a 40% control assay failure rate with undiluted extracts and a 6% failure rate with diluted extracts. Method 1609 failed in only 11% and 3% of undiluted and diluted extracts analyses. Use of sample processing control assay results in the delta-delta Ct method for calculating relative target gene recoveries increased the number of acceptable recovery results. Delta-delta tended to bias recoveries fr

  14. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  15. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    PubMed Central

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  16. SOLVING COPPER CORROSION PROBLEMS WHILE MAINTAINING LEAD CONTROL IN A HIGH ALKALINITY WATER USING ORTHOPHOSPHATE

    EPA Science Inventory

    Lead and Copper Rule sampling in 1992 uncovered high copper levels in many homes in the Indian Hill Water Works, Ohio (IHWW) water system. The 90th percentile copper and lead levels were 1.63 mg/L and 0.012 mg/L, respectively. IHWW supplies water to several suburban communities t...

  17. Method Development and Monitoring of Cyanotoxins in Water ...

    EPA Pesticide Factsheets

    This presentation describes method development of two ambient water LC/MS/MS methods for microcystins, cylindrospermopsin and anatoxin-a. Ruggedness of the methods will be demonstrated by evaluation of quality control samples derived from various water bodies across the country. Presentation at the Central Regional meeting of the American Chemical Society ambient water methods development for cyanotoxins

  18. Cloud-enabled microscopy and droplet microfluidic platform for specific detection of Escherichia coli in water.

    PubMed

    Golberg, Alexander; Linshiz, Gregory; Kravets, Ilia; Stawski, Nina; Hillson, Nathan J; Yarmush, Martin L; Marks, Robert S; Konry, Tania

    2014-01-01

    We report an all-in-one platform - ScanDrop - for the rapid and specific capture, detection, and identification of bacteria in drinking water. The ScanDrop platform integrates droplet microfluidics, a portable imaging system, and cloud-based control software and data storage. The cloud-based control software and data storage enables robotic image acquisition, remote image processing, and rapid data sharing. These features form a "cloud" network for water quality monitoring. We have demonstrated the capability of ScanDrop to perform water quality monitoring via the detection of an indicator coliform bacterium, Escherichia coli, in drinking water contaminated with feces. Magnetic beads conjugated with antibodies to E. coli antigen were used to selectively capture and isolate specific bacteria from water samples. The bead-captured bacteria were co-encapsulated in pico-liter droplets with fluorescently-labeled anti-E. coli antibodies, and imaged with an automated custom designed fluorescence microscope. The entire water quality diagnostic process required 8 hours from sample collection to online-accessible results compared with 2-4 days for other currently available standard detection methods.

  19. Cloud-Enabled Microscopy and Droplet Microfluidic Platform for Specific Detection of Escherichia coli in Water

    PubMed Central

    Kravets, Ilia; Stawski, Nina; Hillson, Nathan J.; Yarmush, Martin L.; Marks, Robert S.; Konry, Tania

    2014-01-01

    We report an all-in-one platform – ScanDrop – for the rapid and specific capture, detection, and identification of bacteria in drinking water. The ScanDrop platform integrates droplet microfluidics, a portable imaging system, and cloud-based control software and data storage. The cloud-based control software and data storage enables robotic image acquisition, remote image processing, and rapid data sharing. These features form a “cloud” network for water quality monitoring. We have demonstrated the capability of ScanDrop to perform water quality monitoring via the detection of an indicator coliform bacterium, Escherichia coli, in drinking water contaminated with feces. Magnetic beads conjugated with antibodies to E. coli antigen were used to selectively capture and isolate specific bacteria from water samples. The bead-captured bacteria were co-encapsulated in pico-liter droplets with fluorescently-labeled anti-E. coli antibodies, and imaged with an automated custom designed fluorescence microscope. The entire water quality diagnostic process required 8 hours from sample collection to online-accessible results compared with 2–4 days for other currently available standard detection methods. PMID:24475107

  20. Surface-water-quality assessment of the Kentucky River Basin, Kentucky; fixed-station network and selected water-quality data, April 1987 through August 1991

    USGS Publications Warehouse

    Griffin, M.S.; Martin, G.R.; White, K.D.

    1994-01-01

    This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.

  1. Membrane Based Thermal Control Development

    NASA Technical Reports Server (NTRS)

    Murdoch, Karen

    1997-01-01

    The investigation of the feasibility of using a membrane device as a water boiler for thermal control is reported. The membrane device permits water vapor to escape to the vacuum of space but prevents the loss of liquid water. The vaporization of the water provides cooling to the water loop. This type of cooling device would have application for various types of short duration cooling needs where expenditure of water is allowed and a low pressure source is available such as in space or on a planet's surface. A variety of membrane samples, both hydrophilic and hydrophobic, were purchased to test for this thermal control application. An initial screening test determined if the membrane could pose a sufficient barrier to maintain water against vacuum. Further testing compared the heat transfer performance of those membranes that passed the screening test.

  2. Strain localization and fabric development in polycrystalline anorthite + melt by water diffusion in an axial deformation experiment

    NASA Astrophysics Data System (ADS)

    Fukuda, Jun-ichi; Muto, Jun; Nagahama, Hiroyuki

    2018-01-01

    We performed two axial deformation experiments on synthetic polycrystalline anorthite samples with a grain size of 3 μm and 5 vol% Si-Al-rich glass at 900 °C, a confining pressure of 1.0 GPa, and a strain rate of 10-4.8 s-1. One sample was deformed as-is (dry); in the other sample, two half-cut samples (two cores) with 0.15 wt% water at the boundary were put together in the apparatus. The mechanical data for both samples were essentially identical with a yield strength of 700 MPa and strain weakening of 500 MPa by 20% strain. The dry sample appears to have been deformed by distributed fracturing. Meanwhile, the water-added sample shows plastic strain localization in addition to fracturing and reaction products composed of zoisite grains and SiO2 materials along the boundary between the two sample cores. Infrared spectra of the water-added sample showed dominant water bands of zoisite. The maximum water content was 1500 wt ppm H2O at the two-core boundary, which is the same as the added amount. The water contents gradually decreased from the boundaries to the sample interior, and the gradient fitted well with the solution of the one-dimensional diffusion equation. The determined diffusion coefficient was 7.4 × 10-13 m2/s, which agrees with previous data for the grain boundary diffusion of water. The anorthite grains in the water-added sample showed no crystallographic preferred orientation. Textural observations and water diffusion indicate that water promotes the plastic deformation of polycrystalline anorthite by grain-size-sensitive creep as well as simultaneous reactions. We calculated the strain rate evolution controlled by water diffusion in feldspar aggregates surrounded by a water source. We assumed water diffusion in a dry rock mass with variable sizes. Diffused water weakens a rock mass with time under compressive stress. The calculated strain rate decreased from 10-10 to 10-15 s-1 with an increase in the rock mass size to which water is supplied from < 1 m to 1 km and an increase in the time of water diffusion from < 1 to 10,000 years. This indicates a decrease in the strain rate in a rock mass with increasing deformation via water diffusion.

  3. The Application of New Molecular Methods in the Investigation of a Waterborne Outbreak of Norovirus in Denmark, 2012

    PubMed Central

    Schultz, Anna Charlotte; Fonager, Jannik; Ethelberg, Steen; Dalgaard, Camilla; Adelhardt, Marianne; Engberg, Jørgen H.; Fischer, Thea Kølsen; Lassen, Sofie Gillesberg

    2014-01-01

    In December 2012, an outbreak of acute gastrointestinal illness occurred in a geographical distinct area in Denmark covering 368 households. A combined microbiological, epidemiological and environmental investigation was initiated to understand the outbreak magnitude, pathogen(s) and vehicle in order to control the outbreak. Norovirus GII.4 New Orleans 2009 variant was detected in 15 of 17 individual stool samples from 14 households. Norovirus genomic material from water samples was detected and quantified and sequencing of longer parts of the viral capsid region (>1000 nt) were applied to patient and water samples. All five purposely selected water samples tested positive for norovirus GII in levels up to 1.8×104 genomic units per 200 ml. Identical norovirus sequences were found in all 5 sequenced stool samples and 1 sequenced water sample, a second sequenced water sample showed 1 nt (<0.1%) difference. In a cohort study, including 256 participants, cases were defined as residents of the area experiencing diarrhoea or vomiting onset on 12–14 December 2012. We found an attack rate of 51%. Being a case was associated with drinking tap-water on 12–13 December (relative risk = 6.0, 95%CI: 1.6–22) and a dose-response relation for the mean glasses of tap-water consumed was observed. Environmental investigations suggested contamination from a sewage pipe to the drinking water due to fall in pressure during water supply system renovations. The combined microbiological, epidemiological and environmental investigations strongly indicates the outbreak was caused by norovirus contamination of the water supply system. PMID:25222495

  4. Instrumentation for a dry-pond detention study

    USGS Publications Warehouse

    Pope, L.M.; Jennings, M.E.; Thibodeaux, K.G.

    1988-01-01

    A 12.3-acre, fully urbanized, residential land-use catchment was instrumented by the U. S. Geological Survey in Topeka, Kansas. Hydraulic instrumentation for flow measurement includes two types of flumes, a pipe-insert flume and a culvert-inlet (manhole) flume. Samples of rainfall and runoff for water-quality analyses were collected by automatic, 3-liter, 24-sample capacity water samples controlled by multichannel data loggers. Ancillary equipment included a raingage and wet/dry atmospheric-deposition sampler. Nineteen stormwater runoff events were monitored at the site using the instrumentation system. The system has a high reliability of data capture and permits an accurate determination of storm-water loads.

  5. Simple method for quantifying microbiologically assisted chloramine decay in drinking water.

    PubMed

    Sathasivan, Arumugam; Fisher, Ian; Kastl, George

    2005-07-15

    In a chloraminated drinking water distribution system, monochloramine decays due to chemical and microbiological reactions. For modeling and operational control purposes, it is necessary to know the relative contribution of each type of reaction, but there was no method to quantify these contributions separately. A simple method was developed to do so. It compares monochloramine decay rates of processed (0.2 microm filtered or microbiologically inhibited by adding 100 microg of silver/L as silver nitrate) and unprocessed samples under controlled temperature conditions. The term microbial decay factor (Fm) was defined and derived from this method, to characterize the relative contribution of microbiologically assisted monochloramine decay to the total monochloramine decay observed in bulk water. Fm is the ratio between microbiologically assisted monochloramine decay and chemical decay of a given water sample measured at 20 degrees C. One possible use of the method is illustrated, where a service reservoir's bulk and inlet waters were sampled twice and analyzed for both the traditional indicators and the microbial decay factor. The microbial decay factor values alone indicated that more microbiologically assisted monochloramine decay was occurring in one bulk water than the other. In contrast, traditional nitrification indicators failed to show any difference. Further analysis showed that the microbial decay factor is more sensitive and that it alone can provide an early warning.

  6. Heavy Metal Contamination in Groundwater around Industrial Estate vs Residential Areas in Coimbatore, India

    PubMed Central

    Mohankumar, K.; Rao, N. Prasada

    2016-01-01

    Introduction Water is the vital resource, necessary for all aspects of human and ecosystem survival and health. Depending on the quality, bore water may be used for human consumption, irrigation purposes and livestock watering. The quality of bore water can vary widely depending on the quality of ground water that is its source. Pollutants are being added to the ground water system through human and natural processes. Solid waste from industrial units is being dumped near the factories, which react with percolating rainwater and reaches the ground water. The percolating water picks up a large number of heavy metals and reaches the aquifer system and contaminates the ground water. The usage of the contaminated bore water causes the diseases. Mercury, Arsenic and Cadmium are used or released by many industries. Aim This study was conducted to investigate the pollution of bore water in the industrial region (Kurichi Industrial Cluster) of Coimbatore, in the state of Tamilnadu, India. Materials and Methods Four samples were taken from residential areas around Kurichi Industrial Cluster and analysed to find the concentrations of Mercury, Arsenic and Cadmium. Four more samples were taken from other residential regions far from the industrial estate and served as control. Samples were analysed using Atomic absorption spectrophotometry method. Results We found that the ground water of the areas surrounding the industrial cluster does not contain significant amount of those metals. Instead, Heavy metal contamination of ground water were observed in some residential areas of coimbatore. Conclusion The regulatory measures to contain and prevent ground water contamination by industries undertaken by Tamilnadu pollution control board may have lead to absence of heavy metal contamination in Kurichi Industrial cluster, Coimbatore, India. PMID:27190788

  7. Evaluation of Bacteriological and Chemical Quality of Dialysis Water and Fluid in Isfahan, Central Iran

    PubMed Central

    SHAHRYARI, Ali; NIKAEEN, Mahnaz; HATAMZADEH, Maryam; VAHID DASTJERDI, Marzieh; HASSANZADEH, Akbar

    2016-01-01

    Background: Chemical and microbial quality of water used in hemodialysis play key roles in a number of dialysis-related complications. In order to avoid the complications and to guarantee safety and health of patients therefore, vigorous control of water quality is essential. The objective of present study was to investigate the chemical and bacteriological characteristics of water used in dialysis centers of five hospitals in Isfahan, central Iran. Methods: A total of 30 water samples from the input of dialysis purification system and dialysis water were analyzed for chemical parameters. Heterotrophic plate count and endotoxin concentration of drinking water, dialysis water and dialysis fluid of 40 machines were also monitored over a 5-month period in 2011–2012. Results: Concentration of the determined chemicals (copper, zinc, sulfate, fluoride, chloramines and free chlorine) did not exceed the recommended concentration by the Association for the Advancement of Medical Instrumentation (AAMI) exclude lead, nitrate, aluminum and calcium. Furthermore, the magnesium; cadmium and chromium concentration exceeded the maximum level in some centers. No contamination with heterotrophic bacteria was observed in all samples, while the AMMI standard for endotoxin level in dialysis fluid (<2 EU/ml) was achieved in 95% of samples. Conclusion: Dialysis water and fluid failed to meet the all chemical and bacteriological requirements for hemodialysis. To minimize the risk of contaminants for hemodialysis patients therefore, a water quality management program including monitoring, maintenance and development of water treatment system in hemodialysis centers is extremely important. In addition, an appropriate disinfection program is needed to guarantee better control of bacterial growth and biofilm formation. PMID:27398338

  8. Potential radiation control of biofouling bacteria on intake filters

    NASA Astrophysics Data System (ADS)

    Eichholz, Geoffrey G.; Jones, Cynthia G.; Haynes, Harold E.

    The biofouling of filters at deep wells supplying water for industrial and drinking water purposes by various iron- and sulfur-reducing bacteria is a wide-spread problem in the United States and can cause serious economic losses. Among the means of control, steam heating or chemical additives can be applied only intermittently and have their own environmental impact. Preliminary studies have shown that installation of a sealed gamma radiation source may provide an alternative solution. Analysis of a range of water samples from contaminated wells identified many of the samples as rich in barsiderocapsa and barpseudomona bacteria. Static and dynamic experiments on water samples at various does and dose rates have shown that these organisms are relatively radiation-sensitive, with a lethal dose in the range of 200-400Gy (20-40kR). Since the main objective is to restrict growth or deposit of plaque on filters, dose rates of the order of 50-75 Gy/hr would be adequate. Such dose rates could be obtained with relatively weak sources, depending on filter dimensions. A conceptual design for such systems has been proposed.

  9. Low Water Activity Packaged White Bread.

    DTIC Science & Technology

    1985-12-31

    this method is different in quality from the normal white pan bread. It has been well recognized that water activity is a key factor in controlling ...important in controlling microbial growth. The purpose of this project was to develop a shelf-stable white pan bread in a flexible pouch by utilizing...coded and randomized in order of presentation. Each judge was presented five samples: control , 5% sorbitol, 20% sorbitol, 8% glycerol, and 10% sorbitol-5

  10. Effects of sterilization treatments on the analysis of TOC in water samples.

    PubMed

    Shi, Yiming; Xu, Lingfeng; Gong, Dongqin; Lu, Jun

    2010-01-01

    Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants. However, the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments. Based on the principle of water total organic carbon (TOC) analysis, the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated. The results revealed that two conventional physical sterilization treatments, autoclaving and 60Co gamma-radiation sterilization, led to the direct decomposition of some organic pollutants, resulting in remarkable errors in the analysis of TOC in water samples. Furthermore, the extent of the errors varied with the intensity and the duration of sterilization treatments. Accordingly, a novel sterilization method for water samples, 0.45 microm micro-filtration coupled with ultraviolet radiation (MCUR), was developed in the present study. The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters. Before and after sterilization treatments, the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.

  11. Quality of surface water in the Suwannee River Basin, Florida, August 1968 through December 1977

    USGS Publications Warehouse

    Hull, Robert W.; Dysart, Joel E.; Mann, William B.

    1981-01-01

    In the 9,950-square mile area of the Suwannee River basin in Florida and Georgia, 17 surface-water stations on 9 streams and several springs were sampled for selected water-quality properties and constituents from August 1968 through December 1977. Analyses from these samples indicate that: (1) the water quality of tributary wetlands controls the water quality of the upper Suwannee River headwaters; (2) groundwater substantially affects the water quality of the Suwannee River basin streams below these headquarters; (3) the water quality of the Suwannee River, and many of its tributaries, is determined by several factors and is not simply related to discharge; and (4) development in the Suwannee River basin has had observable effects on the quality of surface waters. 

  12. Evaluation of quality-control data collected by the U.S. Geological Survey for routine water-quality activities at the Idaho National Laboratory and vicinity, southeastern Idaho, 2002-08

    USGS Publications Warehouse

    Rattray, Gordon W.

    2014-01-01

    Quality-control (QC) samples were collected from 2002 through 2008 by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to ensure data robustness by documenting the variability and bias of water-quality data collected at surface-water and groundwater sites at and near the Idaho National Laboratory. QC samples consisted of 139 replicates and 22 blanks (approximately 11 percent of the number of environmental samples collected). Measurements from replicates were used to estimate variability (from field and laboratory procedures and sample heterogeneity), as reproducibility and reliability, of water-quality measurements of radiochemical, inorganic, and organic constituents. Measurements from blanks were used to estimate the potential contamination bias of selected radiochemical and inorganic constituents in water-quality samples, with an emphasis on identifying any cross contamination of samples collected with portable sampling equipment. The reproducibility of water-quality measurements was estimated with calculations of normalized absolute difference for radiochemical constituents and relative standard deviation (RSD) for inorganic and organic constituents. The reliability of water-quality measurements was estimated with pooled RSDs for all constituents. Reproducibility was acceptable for all constituents except dissolved aluminum and total organic carbon. Pooled RSDs were equal to or less than 14 percent for all constituents except for total organic carbon, which had pooled RSDs of 70 percent for the low concentration range and 4.4 percent for the high concentration range. Source-solution and equipment blanks were measured for concentrations of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, and dissolved chromium. Field blanks were measured for the concentration of iodide. No detectable concentrations were measured from the blanks except for strontium-90 in one source solution and one equipment blank collected in September and October 2004, respectively. The detectable concentrations of strontium-90 in the blanks probably were from a small source of strontium-90 contamination or large measurement variability, or both. Order statistics and the binomial probability distribution were used to estimate the magnitude and extent of any potential contamination bias of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, dissolved chromium, and iodide in water-quality samples. These statistical methods indicated that, with (1) 87 percent confidence, contamination bias of cesium-137 and sodium in 60 percent of water-quality samples was less than the minimum detectable concentration or reporting level; (2) 92‒94 percent confidence, contamination bias of tritium, strontium-90, chloride, sulfate, and dissolved chromium in 70 percent of water-quality samples was less than the minimum detectable concentration or reporting level; and (3) 75 percent confidence, contamination bias of iodide in 50 percent of water-quality samples was less than the reporting level for iodide. These results support the conclusion that contamination bias of water-quality samples from sample processing, storage, shipping, and analysis was insignificant and that cross-contamination of perched groundwater samples collected with bailers during 2002–08 was insignificant.

  13. Multi-pumping flow system for the determination of boron in eye drops, drinking water and ocean water.

    PubMed

    González, Pablo; Sixto, Alexandra; Knochen, Moisés

    2017-05-01

    A novel automated method for the determination of boron based on the use of pulsed flows was developed and applied to the determination of this element in samples of tap water, ocean water and eye drops. The method was implemented by means of a multi-pumping system consisting of three solenoid micropumps and a photometric detector and exploits the reaction of azomethine-H in the presence of boron. The system runs under control of an open-source microcontroller. The main operational parameters were optimized. Given the particular kinetics of the reaction, a stopped-flow period (1 or 5min) was included to allow for color development. The method presents linearity in the range 0.35-3.0mgL -1 , good precision (s r <3%), and detection and quantification limits of 0.10 and 0.35mgL -1 respectively. Samples of tap water or eye drops could be successfully analyzed employing a 1-minute stop time, providing a maximum sampling frequency of 32 samples h -1 . In order to overcome matrix effect caused by the high saline concentration, ocean water samples required stop times of 5min, providing a sampling frequency of 10 samples h -1 . Recoveries of 102% (eye drops), 94% (drinking water) and 93% (ocean water) were obtained. The method was considered accurate and fit for the purpose. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Self-assembly Morphology and Crystallinity Control of Di-block Copolymer Inspired by Spider Silk

    NASA Astrophysics Data System (ADS)

    Huang, Wenwen; Krishnaji, Sreevidhya; Kaplan, David; Cebe, Peggy

    2012-02-01

    To obtain a fuller understanding of the origin of self-assembly behavior, and thus be able to control the morphology of biomaterials with well defined amino acid sequences for tissue regeneration and drug delivery, we created a family of synthetic silk-based block copolymers inspired by the genetic sequences found in spider dragline, HABn and HBAn (n=1,2,3,6), where B = hydrophilic block, A = hydrophobic block, and H is a histidine tag. We assessed the secondary structure of water cast films by Fourier transform infrared spectroscopy (FTIR). The crystallinity was determined by Fourier self-deconvolution of amide I spectra and confirmed by wide angle X-ray diffraction (WAXD). Results indicate that we can control the self-assembled morphology and the crystallinity by varying the block length, and a minimum of 3 A-blocks are required to form beta sheet crystalline regions in water-cast spider silk block copolymers. The morphology and crystallinity can also be tuned by annealing. Thermal properties of water cast films and films annealed at 120 C were determined by differential scanning calorimetry and thermogravimetry. The sample films were also treated with 1,1,1,3,3,3-Hexafluoro-2-propanol (HFIP) to obtain wholly amorphous samples, and crystallized by exposure to methanol. Using scanning and transmission electron microscopies, we observe that fibrillar networks and hollow micelles are formed in water cast and methanol cast samples, but not in samples cast from HFIP.

  15. Transport of fluorobenzoate tracers in a vegetated hydrologic control volume: 1. Experimental results

    NASA Astrophysics Data System (ADS)

    Queloz, Pierre; Bertuzzo, Enrico; Carraro, Luca; Botter, Gianluca; Miglietta, Franco; Rao, P. S. C.; Rinaldo, Andrea

    2015-04-01

    This paper reports about the experimental evidence collected on the transport of five fluorobenzoate tracers injected under controlled conditions in a vegetated hydrologic volume, a large lysimeter (fitted with load cells, sampling ports, and an underground chamber) where two willows prompting large evapotranspiration fluxes had been grown. The relevance of the study lies in the direct and indirect measures of the ways in which hydrologic fluxes, in this case, evapotranspiration from the upper surface and discharge from the bottom drainage, sample water and solutes in storage at different times under variable hydrologic forcings. Methods involve the accurate control of hydrologic inputs and outputs and a large number of suitable chemical analyses of water samples in discharge waters. Mass extraction from biomass has also been performed ex post. The results of the 2 year long experiment established that our initial premises on the tracers' behavior, known to be sorption-free under saturated conditions which we verified in column leaching tests, were unsuitable as large differences in mass recovery appeared. Issues on reactivity thus arose and were addressed in the paper, in this case attributed to microbial degradation and solute plant uptake. Our results suggest previously unknown features of fluorobenzoate compounds as hydrologic tracers, potentially interesting for catchment studies owing to their suitability for distinguishable multiple injections, and an outlook on direct experimental closures of mass balance in hydrologic transport volumes involving fluxes that are likely to sample differently stored water and solutes.

  16. Improving distillation method and device of tritiated water analysis for ultra high decontamination efficiency.

    PubMed

    Fang, Hsin-Fa; Wang, Chu-Fang; Lin, Chien-Kung

    2015-12-01

    It is important that monitoring environmental tritiated water for understanding the contamination dispersion of the nuclear facilities. Tritium is a pure beta radionuclide which is usually measured by Liquid Scintillation Counting (LSC). The average energy of tritum beta is only 5.658 keV that makes the LSC counting of tritium easily be interfered by the beta emitted by other radionuclides. Environmental tritiated water samples usually need to be decontaminated by distillation for reducing the interference. After Fukushima Nucleaer Accident, the highest gross beta concentration of groundwater samples obtained around Fukushima Daiichi Nuclear Power Station is over 1,000,000 Bq/l. There is a need for a distillation with ultra-high decontamination efficiency for environmental tritiated water analysis. This study is intended to improve the heating temperature control for better sub-boiling distillation control and modify the height of the container of the air cooling distillation device for better fractional distillation effect. The DF of Cs-137 of the distillation may reach 450,000 which is far better than the prior study. The average loss rate of the improved method and device is about 2.6% which is better than the bias value listed in the ASTM D4107-08. It is proven that the modified air cooling distillation device can provide an easy-handling, water-saving, low cost and effective way of purifying water samples for higher beta radionuclides contaminated water samples which need ultra-high decontamination treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Ecology of Vibrio vulnificus in estuarine waters of eastern North Carolina.

    PubMed

    Pfeffer, Courtney S; Hite, M Frances; Oliver, James D

    2003-06-01

    While several studies on the ecology of Vibrio vulnificus in Gulf Coast environments have been reported, there is little information on the distribution of this pathogen in East Coast waters. Thus, we conducted a multiyear study on the ecology of V. vulnificus in estuarine waters of the eastern United States, employing extensive multiple regression analyses to reveal the major environmental factors controlling the presence of this pathogen, and of Vibrio spp., in these environments. Monthly field samplings were conducted between July 2000 and April 2002 at six different estuarine sites along the eastern coast of North Carolina. At each site, water samples were taken and nine physicochemical parameters were measured. V. vulnificus isolates, along with estuarine bacteria, Vibrio spp., Escherichia coli organisms, and total coliforms, were enumerated in samples from each site by using selective media. During the last 6 months of the study, sediment samples were also analyzed for the presence of vibrios, including V. vulnificus. Isolates were confirmed as V. vulnificus by using hemolysin gene PCR or colony hybridization. V. vulnificus was isolated only when water temperatures were between 15 and 27 degrees C, and its presence correlated with water temperature and dissolved oxygen and vibrio levels. Levels of V. vulnificus in sediments were low, and no evidence for an overwintering in this environment was found. Multiple regression analysis indicated that vibrio levels were controlled primarily by temperature, turbidity, and levels of dissolved oxygen, estuarine bacteria, and coliforms. Water temperature accounted for most of the variability in the concentrations of both V. vulnificus (47%) and Vibrio spp. (48%).

  18. Occurrence of Blastocystis sp. in water catchments at Malay villages and Aboriginal settlement during wet and dry seasons in Peninsular Malaysia

    PubMed Central

    Noradilah, Samseh Abdullah; Lee, Ii Li; Anuar, Tengku Shahrul; Salleh, Fatmah Md; Abdul Manap, Siti Nor Azreen; Mohd Mohtar, Noor Shazleen Husnie; Azrul, Syed Muhamad; Abdullah, Wan Omar

    2016-01-01

    In the tropics, there are too few studies on isolation of Blastocystis sp. subtypes from water sources; in addition, there is also an absence of reported studies on the occurrence of Blastocystis sp. subtypes in water during different seasons. Therefore, this study was aimed to determine the occurrence of Blastocystis sp. subtypes in river water and other water sources that drained aboriginal vicinity of highly endemic intestinal parasitic infections during wet and dry seasons. Water samples were collected from six sampling points of Sungai Krau (K1–K6) and a point at Sungai Lompat (K7) and other water sources around the aboriginal villages. The water samples were collected during both seasons, wet and dry seasons. Filtration of the water samples were carried out using a flatbed membrane filtration system. The extracted DNA from concentrated water sediment was subjected to single round polymerase chain reaction and positive PCR products were subjected to sequencing. All samples were also subjected to filtration and cultured on membrane lactose glucuronide agar for the detection of faecal coliforms. During wet season, Blastocystis sp. ST1, ST2 and ST3 were detected in river water samples. Blastocystis sp. ST3 occurrence was sustained in the river water samples during dry season. However Blastocystis sp. ST1 and ST2 were absent during dry season. Water samples collected from various water sources showed contaminations of Blastocystis sp. ST1, ST2, ST3 and ST4, during wet season and Blastocystis sp. ST1, ST3, ST8 and ST10 during dry season. Water collected from all river sampling points during both seasons showed growth of Escherichia coli and Enterobacter aerogenes, indicating faecal contamination. In this study, Blastocystis sp. ST3 is suggested as the most robust and resistant subtype able to survive in any adverse environmental condition. Restriction and control of human and animal faecal contaminations to the river and other water sources shall prevent the transmission of Blastocystis sp. to humans and animals in this aboriginal community. PMID:27761331

  19. Design, development, and field demonstration of a remotely deployable water quality monitoring system

    NASA Technical Reports Server (NTRS)

    Wallace, J. W.; Lovelady, R. W.; Ferguson, R. L.

    1981-01-01

    A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

  20. Impact of effluents from a car battery manufacturing plant in Nigeria on water, soil, and food qualities.

    PubMed

    Orisakwe, Orish Ebere; Asomugha, Rose; Afonne, Onyenmechi Johnson; Anisi, C N; Obi, Ejeatuluchukwualo; Dioka, Chudi Emma

    2004-01-01

    The authors investigated the impact of effluents from a car battery manufacturing plant in Nnewi, Nigeria, on water, soil, and food qualities. The authors analyzed heavy metals mercury, arsenic, lead, cadmium and nickel in tap and cassava waters, soil, dried cassava tuber, and edible fruit samples from the company, using an atomic absorption spectrophotometer. Other parameters the authors analyzed include pH, electrical conductivity (EC), salinity (SAL), total hardness (TH), biological oxygen demand (BOD), volatile and non-volatile solids, and bacterial and fungal loads of the soil samples. Results show that lead had the highest concentration in all the samples, with the soil samples having the highest lead concentration (38-12 ppm, 102 ppm) and the water samples having the lowest (0.02-0.20 ppm). Mercury had the lowest concentration (<0.0002 ppm) in all the samples. Soil sample B had the highest concentration of all the metals tested. Cassava water had higher levels of EC, SAL, TH, BOD, and volatile and nonvolatile solids, but lower pH than tap water. Bacterial loads were higher than fungal loads in all the soil samples. Because there was moderate contamination of the environment by some of the metals studied, with lead being exceptionally high and above the specified international standards, the authors recommend control measures to reduce lead exposure to the local populace within and around this industry.

  1. Diagenetic and compositional controls of wettability in siliceous sedimentary rocks, Monterey Formation, California

    NASA Astrophysics Data System (ADS)

    Hill, Kristina M.

    Modified imbibition tests were performed on 69 subsurface samples from Monterey Formation reservoirs in the San Joaquin Valley to measure wettability variation as a result of composition and silica phase change. Contact angle tests were also performed on 6 chert samples from outcrop and 3 nearly pure mineral samples. Understanding wettability is important because it is a key factor in reservoir fluid distribution and movement, and its significance rises as porosity and permeability decrease and fluid interactions with reservoir grain surface area increase. Although the low permeability siliceous reservoirs of the Monterey Formation are economically important and prolific, a greater understanding of factors that alter their wettability will help better develop them. Imbibition results revealed a strong trend of decreased wettability to oil with increased detrital content in opal-CT phase samples. Opal-A phase samples exhibited less wettability to oil than both opal-CT and quartz phase samples of similar detrital content. Subsurface reservoir samples from 3 oil fields were crushed to eliminate the effect of capillary pressure and cleansed of hydrocarbons to eliminate wettability alterations by asphaltene, then pressed into discs of controlled density. Powder discs were tested for wettability by dispensing a controlled volume of water and motor oil onto the surface and measuring the time required for each fluid to imbibe into the sample. The syringe and software of a CAM101 tensiometer were used to control the amount of fluid dispensed onto each sample, and imbibition completion times were determined by high-speed photography for water drops; oil drop imbibition was significantly slower and imbibition was timed and determined visually. Contact angle of water and oil drops on polished chert and mineral sample surfaces was determined by image analysis and the Young-Laplace equation. Oil imbibition was significantly slower with increased detrital composition and faster with increased silica content in opal-CT and quartz phase samples, implying decreased wettability to oil with increased detrital (clay) content. However, contact angle tests showed that opal-CT is more wetting to oil with increased detritus and results for oil on quartz-phase samples were inconsistent between different proxies for detritus over their very small compositional range. Water contact angle trends also showed inconsistent wetting trends compared to imbibition tests. We believe this is because the small range in bulk detrital composition between the "pure" samples used in contact angle tests was close to analytical error and because small-scale spatial compositional variability may be significant enough to effect wettability. These experiments show that compositional variables significantly affect wettability, outweighing the effect of silica phase.

  2. Household-based ceramic water filters for the prevention of diarrhea: a randomized, controlled trial of a pilot program in Colombia.

    PubMed

    Clasen, Thomas; Garcia Parra, Gloria; Boisson, Sophie; Collin, Simon

    2005-10-01

    Household water treatment is increasingly recognized as an effective means of reducing the burden of diarrheal disease among low-income populations without access to safe water. Oxfam GB undertook a pilot project to explore the use of household-based ceramic water filters in three remote communities in Colombia. In a randomized, controlled trial over a period of six months, the filters were associated with a 75.3% reduction in arithmetic mean thermotolerant coliforms (TTCs) (P < 0.0001). A total of 47.7% and 24.2% of the samples from the intervention group had no detectible TTCs/100 mL or conformed to World Health Organization limits for low risk (1-10 TTCs/100 mL), respectively, compared with 0.9% and 7.3% for control group samples. Overall, prevalence of diarrhea was 60% less among households using filters than among control households (odds ratio = 0.40, 95% confidence interval = 0.25, 0.63, P < 0.0001). However, the microbiologic performance and protective effect of the filters was not uniform throughout the study communities, suggesting the need to consider the circumstances of the particular setting before implementing this intervention.

  3. Variables controlling the recovery of ignitable liquid residues from simulated fire debris samples using solid-phase microextraction/gas chromatography

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Almirall, Jose R.; Wang, Jing

    1999-02-01

    In this paper, we present data comparing a variety of different conditions for extracting ignitable liquid residues from simulated fire debris samples in order to optimize the conditions for using Solid Phase Microextraction. A simulated accelerant mixture containing 30 components, including those from light petroleum distillates, medium petroleum distillates and heavy petroleum distillates were used to study the important variables controlling Solid Phase Microextraction (SPME) recoveries. SPME is an inexpensive, rapid and sensitive method for the analysis of volatile residues from the headspace over solid debris samples in a container or directly from aqueous samples followed by GC. The relative effects of controllable variables, including fiber chemistry, adsorption and desorption temperature, extraction time, and desorption time, have been optimized. The addition of water and ethanol to simulated debris samples in a can was shown to increase the sensitivity when using headspace SPME extraction. The relative enhancement of sensitivity has been compared as a function of the hydrocarbon chain length, sample temperature, time, and added ethanol concentrations. The technique has also been optimized to the extraction of accelerants directly from water added to the fire debris samples. The optimum adsorption time for the low molecular weight components was found to be approximately 25 minutes. The high molecular weight components were found at a higher concentration the longer the fiber was exposed to the headspace (up to 1 hr). The higher molecular weight components were also found in higher concentrations in the headspace when water and/or ethanol was added to the debris.

  4. What can d7Li tell us about sources and flow pathes of river water (Western Pamir, Tajikistan)?

    NASA Astrophysics Data System (ADS)

    Meier, Christiane; Knoche, Malte; Osenbrück, Karsten; Seitz, Hans-Michael; Weise, Stephan M.

    2015-04-01

    The high alpine regions in Central Asia are the headwaters for big river systems such as the Amu Darya, which is intensively used for agricultural purposes. For the local water resources management it is important to understand the key factors and processes of runoff generation. It is assumed, that the dominant factors for runoff generation are glacier and snow melt in the Pamir Mountains. However the influence of ground water to river water is also an important factor but still not well understood. We investigated the River Gunt catchment as an exemplary catchment for the Pamir Mountains to identify the origin and to quantify the portion of ground water. Thereby we analyzed water samples of river water, subsurface water, thermal water and glacier water for 7Li. We detected a wide range of 7Li values (from +7‰ to +30‰), whereas the highest values were measured in the glacier melt water at the glacier snout (7Li = +28.8‰) which are similar to the 7Li value of sea water, the lowest values were found in the samples of thermal water and springs in solid rock (7Li between +8‰ and +11‰), the samples of river water are more or less placed on a mixing line in between. We assume that tributaries showing an isotope signature similar to the glacier ones are mainly controlled by melt water while water samples with 7Li values comparable to the 7Li values of subsurface water samples pass through the underground or have a strong interaction between river water and river bed. The water samples of the main stream Gunt also show low 7Li values so we assume a strong contribution of subsurface water to the total runoff or an intensive water-rock-interaction in its riverbed.

  5. Small amount of water induced preparation of several morphologies for InBO3:Eu3+ phosphor via a facile boric acid flux method and their luminescent properties

    NASA Astrophysics Data System (ADS)

    Ding, Wen; Liang, Pan; Liu, Zhi-Hong

    2017-05-01

    Four kinds of morphologies for InBO3:Eu3+ phosphor have been prepared via a facile boric acid flux method only by adjusting the small amount of added water. The prepared samples have been characterized by XRD, FT-IR, and SEM. It was found that the size and morphology of the samples could be effectively controlled by adjusting reaction temperature, reaction time, especially the small amount of added water, which plays an extremely critical role in the controlling morphology. The possible growth mechanisms for microsphere and flower-like morphologies were further discussed on the basis of time-dependent experiments. Furthermore, the luminescence properties of prepared InBO3:Eu3+ samples have been investigated by photoluminescence (PL) spectra. The results show that the InBO3:Eu3+ phosphors show strong orange emissions under ultraviolet excitation at 237 nm. The monodisperse microsphere sample possesses the highest PL intensity among above four morphologies, which can be used as a potential orange luminescent material.

  6. Evaluation and use of a diffusion-controlled sampler for determining chemical and dissolved oxygen gradients at the sediment-water interface

    USGS Publications Warehouse

    Simon, N.S.; Kennedy, M.M.; Massoni, C.S.

    1985-01-01

    Field and laboratory evaluations were made of a simple, inexpensive diffusion-controlled sampler with ports on two sides at each interval which incorporates 0.2-??m polycarbonate membrane to filter samples in situ. Monovalent and divalent ions reached 90% of equilibrium between sampler contents and the external solution within 3 and 6 hours, respectively. Sediment interstitial water chemical gradients to depths of tens of centimeters were obtained within several days after placement. Gradients were consistent with those determined from interstitial water obtained by centrifugation of adjacent sediment. Ten milliliter sample volumes were collected at 1-cm intervals to determine chemical gradients and dissolved oxygen profiles at depth and at the interface between the sediment and water column. The flux of dissolved species, including oxygen, across the sediment-water interface can be assessed more accurately using this sampler than by using data collected from benthic cores. ?? 1985 Dr W. Junk Publishers.

  7. 33 CFR 159.317 - Sampling and reporting.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Sampling and reporting. 159.317... Operations § 159.317 Sampling and reporting. (a) The owner, operator, master or other person in charge of a.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...

  8. 33 CFR 159.317 - Sampling and reporting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sampling and reporting. 159.317... Operations § 159.317 Sampling and reporting. (a) The owner, operator, master or other person in charge of a.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...

  9. Implementation guide for turbidity threshold sampling: principles, procedures, and analysis

    Treesearch

    Jack Lewis; Rand Eads

    2009-01-01

    Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...

  10. [A novel ship-borne positive pressure solid phase extraction device to enrich organo chlorinated and pyrethroid pesticides in seawater].

    PubMed

    Ye, Jianglei

    2017-09-08

    A novel solid phase extraction (SPE) device driven by positive pressure was developed instead of negative pressure from a vacuum pump, in order to enrich organo chlorinated and pyrethroid pesticides in seawater. The water sampling bottles and the pipelines which touch water samples were made of plastic material without chlorine. In order to ensure the sealing and firmness, the whole device were tightened with nut and bolt. The inner pressure (0.1-0.3 MPa) in the water sampling bottle was provided by the small air pump (powered by 12 V cell) controlled by a microprogrammed control unit (MCU) and pressure sensor to keep the water flow rate (4.0-6.0 mL/min). The pre-conditioned SPE column can be used for the enrichment of pesticides within four weeks, and the loaded SPE column can be eluted for detection within six weeks with recoveries greater than 80%. The linearity of the method was good with the correlation coefficient more than 0.9. The limits of quantification (LOQs) were 0.8-6 ng/L. The recoveries of the pesticides at three spiked levels (3 parallel samples) were 86.1%-95.5% with the relative standard deviations less than 10%. The benzene hexachlorides (BHCs) and dichloro-diphenyl-trichloroethanes (DDTs) were detected in seawater samples. The device has good application in enriching organo chlorinated and pyrethroid pesticides in seawater.

  11. User's guide for polyethylene-based passive diffusion bag samplers to obtain volatile organic compound concentrations in wells. Part I, Deployment, recovery, data interpretation, and quality control and assurance

    USGS Publications Warehouse

    Vroblesky, Don A.

    2001-01-01

    Diffusion samplers installed in observation wells were found to be capable of yielding representative water samples for chlorinated volatile organic compounds. The samplers consisted of polyethylene bags containing deionized water and relied on diffusion of chlorinated volatile organic compounds through the polyethylene membrane. The known ability of polyethylene to transmit other volatile compounds, such as benzene and toluene, indicates that the samplers can be used for a variety of volatile organic compounds. In wells at the study area, the volatile organic compound concentrations in water samples obtained using the samplers without prior purging were similar to concentrations in water samples obtained from the respective wells using traditional purging and sampling approaches. The low cost associated with this approach makes it a viable option for monitoring large observation-well networks for volatile organic compounds.

  12. Measurement and Modeling of Water-Vapor Diffusion in Elastomers with Impact in Humidity and Vacuum Measurements

    NASA Astrophysics Data System (ADS)

    Šetina, Janez; Sefa, Makfir; Erjavec, Bojan; Hudoklin, Domen

    2013-03-01

    The dynamics of water-vapor dissolution in Viton O-rings is measured with a gravimetric method using a precise mass comparator. A sample gasket was degassed in high vacuum for a sufficiently long period to remove more than 99 % of the dissolved water vapor. After that, it was exposed to the ambient atmosphere with a controlled temperature, and relative humidity and water-vapor uptake curves were measured gravimetrically with a precise balance. The dynamics of a water-vapor release into vacuum from another sample that was previously saturated with water vapor at room temperature was determined. The sample was placed in a vacuum outgassing rate measurement apparatus. The time dependence of the evolved water vapor was calculated by integrating the measured outgassing rate. The physical process of water absorption can be described by the diffusion equation. The geometry of the samples required solving the diffusion equation in cylindrical coordinates. This was done numerically using a finite-difference method. As a result of the modeling, room temperature values of the diffusion constant D, the solubility s, and the permeability K = D× s of water vapor in the sample material (Viton A-401C) were obtained. For sample 1, we obtained D = 8.0 × 10 ^{-8} cm2 {\\cdot } s^{-1} and s = 6.5 × 10^{-7} g {\\cdot } cm^-3 Pa^{-1}, while for sample 2, D = 3.0 × 10^{-7} cm2 s^{-1} and s = 3.5 × 10^{-7} g {\\cdot } cm^{-3} {\\cdot } Pa^{-1}.

  13. Water-resources data network evaluation for Monterey County, California; Phase 2, northern and coastal areas of Monterey County

    USGS Publications Warehouse

    Templin, W.E.; Smith, P.E.; DeBortoli, M.L.; Schluter, R.C.

    1995-01-01

    This report presents an evaluation of water- resources data-collection networks in the northern and coastal areas of Monterey County, California. This evaluation was done by the U.S. Geological Survey in cooperation with the Monterey County Flood Control and Water Conservation District to evaluate precipitation, surface water, and ground water monitoring networks. This report describes existing monitoring networks in the study areas and areas where possible additional data-collection is needed. During this study, 106 precipitation-quantity gages were identified, of which 84 were active; however, no precipitation-quality gages were identified in the study areas. The precipitaion-quantity gages were concentrated in the Monterey Peninsula and the northern part of the county. If the number of gages in these areas were reduced, coverage would still be adequate to meet most objectives; however, additional gages could improve coverage in the Tularcitos Creek basin and in the coastal areas south of Carmel to the county boundary. If collection of precipitation data were expanded to include monitoring precipitation quality, this expanded monitoring also could include monitoring precipitation for acid rain and pesticides. Eleven continuous streamflow-gaging stations were identified during this study, of which seven were active. To meet the objectives of the streamflow networks outlined in this report, the seven active stations would need to be continued, four stations would need to be reactivated, and an additional six streamflow-gaging stations would need to be added. Eleven stations that routinely were sampled for chemical constituents were identified in the study areas. Surface water in the lower Big Sur River basin was sampled annually for total coli- form and fecal coliform bacteria, and the Big Sur River was sampled monthly at 16 stations for these bacteria. Routine sampling for chemical constituents also was done in the Big Sur River basin. The Monterey County Flood Control and Water Conservation District maintained three networks in the study areas to measure ground-water levels: (1) the summer network, (2) the monthly network, and (3) the annual autumn network. The California American Water Company also did some ground-water-level monitoring in these areas. Well coverage for ground-water monitoring was dense in the seawater-intrusion area north of Moss Landing (possibly because of multiple overlying aquifers), but sparse in other parts of the study areas. During the study, 44 sections were identified as not monitored for ground-water levels. In an ideal ground-water-level network, wells would be evenly spaced, except where local conditions or correlations of wells make monitoring unnecessary. A total of 384 wells that monitor ground-water levels and/or ground-water quality were identified during this study. The Monterey County Flood Control and Water Conservation District sampled ground-water quality monthly during the irrigation season to monitor seawater intrusion. Once each year (during the summer), the wells in this network were monitored for chlorides, specific conductance, and nitrates. Additional samples were collected from each well once every 5 years for complete mineral analysis. The California Department of Health Services, the California American Water Company, the U.S. Army Health Service at Ford Ord, and the Monterey Peninsula Water Management District also monitored ground-water quality in wells in the study areas. Well coverage for the ground-water- quality networks was dense in the seawater- intrusion area north of Moss Landing, but sparse in the rest of the study areas. During this study, 54 sections were identified as not monitored for water quality.

  14. Multichannel infrared fiber optic radiometer for controlled microwave heating

    NASA Astrophysics Data System (ADS)

    Drizlikh, S.; Zur, Albert; Katzir, Abraham

    1990-07-01

    An infrared fiberoptic multichannel radiometer was used for monitoring and controlling the temperature of samples in a microwave heating system. The temperature of water samples was maintained at about 40 °C, with a standard deviation of +/- 0.2°C and a maximum deviation of +/- 0.5°C. The temperature was monitored on the same time at several points on the surface and inside the sample. This novel controlled system is reliable and precise. Such system would be very useful for medical applications such as hypothermia and hyperthermi a.

  15. Analysis of results obtained using the automatic chemical control of the quality of the water heat carrier in the drum boiler of the Ivanovo CHP-3 power plant

    NASA Astrophysics Data System (ADS)

    Larin, A. B.; Kolegov, A. V.

    2012-10-01

    Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler ( P d = 13.8 MPa) are described. The possibility of using an H-cationite column for measuring the electric conductivity of an H-cationized sample of boiler water over a long period of time is shown.

  16. Escherichia coli Concentrations in Recreational Streams and Backcountry Drinking-Water Supplies in Shenandoah National Park, Virginia, 2005-2006

    USGS Publications Warehouse

    Hyer, Kenneth

    2007-01-01

    Although fecal contamination of streams is a problem of national scope, few investigations have been directed at relatively pristine streams in forested basins in national parks. With approximately 1.8 million visitors annually, Shenandoah National Park in Virginia is subject to extensive recreational use. The effects of these visitors and their recreational activities on fecal indicator bacteria levels in the streams are poorly understood and of concern for Shenandoah National Park managers. During 2005 and 2006, streams and springs in Shenandoah National Park were sampled for Escherichia coli (E. coli) concentrations. The first study objective was to evaluate the effects of recreational activities on E. coli concentrations in selected streams. Of the 20 streams that were selected, 14 were in basins with extensive recreational activity, and 6 were in control basins where minimal recreational activities occurred. Water-quality sampling was conducted during low-flow conditions during the relatively warm months, as this is when outdoor recreation and bacterial survivorship are greatest. Although most sampling was conducted during low-flow conditions, approximately three stormflow samples were collected from each stream. The second study objective was to evaluate E. coli levels in backcountry drinking-water supplies throughout Shenandoah National Park. Nineteen drinking-water supplies (springs and streams) were sampled two to six times each by Shenandoah National Park staff and analyzed by the U.S. Geological Survey for this purpose. The water-quality sampling results indicated relatively low E. coli concentrations during low-flow conditions, and no statistically significant increase in E. coli concentrations was observed in the recreational streams relative to the control streams. These results indicate that during low-flow conditions, recreational activities had no significant effect on E. coli concentrations. During stormflow conditions, E. coli concentrations increased by nearly a factor of 10 in both basin types, and the Virginia instantaneous water-quality standard for E. coli (235 colonies per 100 milliliters) frequently was exceeded. The sampling results from drinking-water supplies throughout Shenandoah National Park indicated relatively low E. coli concentrations in all springs that were sampled. Several of the streams that were sampled had slightly higher E. coli concentrations relative to the springs, but no E. coli concentrations exceeded the instantaneous water-quality standard. Although E. coli concentrations in all the drinking-water supplies were relatively low, Shenandoah National Park management continues to stress that all hikers must treat drinking water from all streams and springs prior to consumption. After determining that recreational activities in Shenandoah National Park did not have a statistically significant effect on low-flow E. coli concentrations, an additional concern was addressed regarding the quality of the water releases from the wastewater-treatment plants in the park. Sampling of three wastewater-treatment plant outfalls was conducted in 2006 to evaluate their effects on water quality. Samples were analyzed for E. coli and a collection of wastewater organic compounds that may be endocrine disruptors. Relatively elevated E. coli concentrations were observed in 2 of the 3 samples, and between 9 and 13 wastewater organic compounds were detected in the samples, including 3 known and 5 suspected endocrine-disrupting compounds.

  17. Microbial biofilm studies of the environmental control and life support system water recovery test for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Rodgers, E. B.; Obenhuber, D. C.; Huff, T. L.

    1992-01-01

    NASA is developing a water recovery system (WRS) for Space Station Freedom to reclaim human waste water for reuse by astronauts as hygiene or potable water. A water recovery test (WRT) currently in progress investigates the performance of a prototype of the WRS. Analysis of biofilm accumulation, the potential for microbially influenced corrosion (MIC) in the WRT, and studies of iodine disinfection of biofilm are reported. Analysis of WRT components indicated the presence of organic deposits and biofilms in selected tubing. Water samples for the WRT contained acid-producing and sulfate-reducing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples; however, stainless steel corrosion rates were not accelerated. Biofilm iodine sensitivity tests using an experimental laboratory scale recycled water system containing a microbial check valve (MCV) demonstrated that an iodine concentration of 1 to 2 mg/L was ineffective in eliminating microbial biofilm. For complete disinfection, an initial concentration of 16 mg/L was required, which was gradually reduced by the MCV over 4 to 8 hours to 1 to 2 mg/L. This treatment may be useful in controlling biofilm formation.

  18. Molecular Characterization of Human-Pathogenic Microsporidia and Cyclospora cayetanensis Isolated from Various Water Sources in Spain: a Year-Long Longitudinal Study

    PubMed Central

    Galván, Ana Luz; Magnet, Angela; Izquierdo, Fernando; Fenoy, Soledad; Rueda, Cristina; Fernández Vadillo, Carmen; Henriques-Gil, Nuno

    2013-01-01

    Recent studies suggest the involvement of water in the epidemiology of Cyclospora cayetanensis and some microsporidia. A total of 223 samples from four drinking water treatment plants (DWTPs), seven wastewater treatment plants (WWTPs), and six locations of influence (LI) on four river basins from Madrid, Spain, were analyzed from spring 2008 to winter 2009. Microsporidia were detected in 49% of samples (109/223), Cyclospora spp. were detected in 9% (20/223), and both parasites were found in 5.4% (12/223) of samples. Human-pathogenic microsporidia were detected, including Enterocytozoon bieneusi (C, D, and D-like genotypes), Encephalitozoon intestinalis, Encephalitozoon cuniculi (genotypes I and III), and Anncaliia algerae. C. cayetanensis was identified in 17 of 20 samples. To our knowledge, this is the first study that shows a year-long longitudinal study of C. cayetanensis in drinking water treatment plants. Additionally, data about the presence and molecular characterization of the human-pathogenic microsporidia in drinking water, wastewater, and locations of influence during 1 year in Spain are shown. It is noteworthy that although the DWTPs and WWTPs studied meet European and national regulations on water sanitary quality, both parasites were found in water samples from these plants, supporting the idea that new and appropriate controls and regulations for drinking water, wastewater, and recreational waters should be proposed to avoid health risks from these pathogens. PMID:23124243

  19. Genotoxic Potential and Physicochemical Parameters of Sinos River, Southern Brazil

    PubMed Central

    Scalon, Madalena C. S.; Rechenmacher, Ciliana; Siebel, Anna Maria; Kayser, Michele L.; Rodrigues, Manoela T.; Maluf, Sharbel W.; Rodrigues, Marco Antonio S.

    2013-01-01

    The present study aimed to evaluate the physicochemical parameters and the genotoxic potential of water samples collected in the upper, middle, and lower courses of the Sinos River, southern Brazil. The comet assay was performed in the peripheral blood of fish Hyphessobrycon luetkenii exposed under laboratory conditions to water samples collected in summer and winter in three sampling sites of Sinos River. Water quality analysis demonstrated values above those described in Brazilian legislation in Parobé and Sapucaia do Sul sites, located in the middle and in the lower courses of the Sinos River, respectively. The Caraá site, located in the upper river reach, presented all the physicochemical parameters in accordance with the allowed limits in both sampling periods. Comet assay in fish revealed genotoxicity in water samples collected in the middle course site in summer and in the three sites in winter when compared to control group. Thus, the physicochemical parameters indicated that the water quality of the upper course complies with the limits set by the national guidelines, and the ecotoxicological assessment, however, indicated the presence of genotoxic agents. The present study highlights the importance of combining water physicochemical analysis and bioassays to river monitoring. PMID:24285934

  20. Effect of highways and local activities on the quality of underground water in Ogun State, Nigeria: a case study of three districts in Ogun State, Nigeria.

    PubMed

    Odukoya, Olusegun O; Onianwa, Percy C; Sanusi, Olanrewaju I

    2010-09-01

    The effect of highways and local activities on the quality of groundwater in Ogun State, Nigeria was investigated. This was done by collecting groundwater samples from three different districts in the state, located in Southwestern Nigeria. The water samples collected at 5 m from the highway and control samples collected at 3 km from the highway were analyzed for the following physicochemical parameters: pH, conductivity, chemical oxygen demand, alkalinity, total hardness, total solid, suspended solid, dissolved solid, chloride, sulfate, phosphate, nitrate, phenol, and the metals-lead, zinc, iron, aluminum, sodium, and potassium. The levels of chromium, copper, and cadmium in the samples were below the detectable limit. The levels of the parameters show that there are significant differences between those in the samples and the controls (F test) except for phosphate and phenol. Also, anthropogenic sources (local activities) elevate the levels of different specific parameters, which are related to these activities. Good correlation was observed between traffic density and lead levels as well as between conductivity and dissolved solids. Comparisons with the World Health Organization guidelines indicate that most of the water samples are not suitable for human consumption.

  1. Quality of drinking water from the agricultural area treated with pitcher water filters

    PubMed

    Królak, Elżbieta; Raczuk, Jolanta; Sakowicz, Danuta; Biardzka, Elżbieta

    Home methods of drinking water treatment through filtration have recently become quite popular. The aim of the study was to compare chemical composition of unfiltered water with water filtered in households with pitcher water filters. Obtained results were discussed in view of the effect of analysed chemical components of water on human health. Water samples were taken from water works supplies and from home dug wells from the agricultural area. Unfiltered water and water filtered through filters filled with active carbon and ion-exchanging resin and placed in a pitcher were analysed. Electrolytic conductivity, pH, hardness and the concentrations of calcium, magnesium, nitrate, phosphate and chloride ions were determined in water samples. Results of analyses were statistically processed. As a result of water filtration, the concentration of phosphates significantly increased and the concentrations of calcium, magnesium, electrolytic conductivity and pH decreased. No changes were noted in the concentration of chloride ions. Filtering water decreased the concentration of nitrates in dug wells samples. Using water purification devices is justified in the case of water originating from home dug wells contaminated with nitrates when, at the same time, consumers’ diet is supplemented with calcium and magnesium. Filtration of water from water works supplies, controlled by sanitary inspection seems aimless.

  2. Development of a nucleic Acid extraction procedure for simultaneous recovery of DNA and RNA from diverse microbes in water.

    PubMed

    Hill, Vincent R; Narayanan, Jothikumar; Gallen, Rachel R; Ferdinand, Karen L; Cromeans, Theresa; Vinjé, Jan

    2015-05-26

    Drinking and environmental water samples contain a diverse array of constituents that can interfere with molecular testing techniques, especially when large volumes of water are concentrated to the small volumes needed for effective molecular analysis. In this study, a suite of enteric viruses, bacteria, and protozoan parasites were seeded into concentrated source water and finished drinking water samples, in order to investigate the relative performance of nucleic acid extraction techniques for molecular testing. Real-time PCR and reverse transcription-PCR crossing threshold (CT) values were used as the metrics for evaluating relative performance. Experimental results were used to develop a guanidinium isothiocyanate-based lysis buffer (UNEX buffer) that enabled effective simultaneous extraction and recovery of DNA and RNA from the suite of study microbes. Procedures for bead beating, nucleic acid purification, and PCR facilitation were also developed and integrated in the protocol. The final lysis buffer and sample preparation procedure was found to be effective for a panel of drinking water and source water concentrates when compared to commercial nucleic acid extraction kits. The UNEX buffer-based extraction protocol enabled PCR detection of six study microbes, in 100 L finished water samples from four drinking water treatment facilities, within three CT values (i.e., within 90% difference) of the reagent-grade water control. The results from this study indicate that this newly formulated lysis buffer and sample preparation procedure can be useful for standardized molecular testing of drinking and environmental waters.

  3. Development of a Nucleic Acid Extraction Procedure for Simultaneous Recovery of DNA and RNA from Diverse Microbes in Water

    PubMed Central

    Hill, Vincent R.; Narayanan, Jothikumar; Gallen, Rachel R.; Ferdinand, Karen L.; Cromeans, Theresa; Vinjé, Jan

    2015-01-01

    Drinking and environmental water samples contain a diverse array of constituents that can interfere with molecular testing techniques, especially when large volumes of water are concentrated to the small volumes needed for effective molecular analysis. In this study, a suite of enteric viruses, bacteria, and protozoan parasites were seeded into concentrated source water and finished drinking water samples, in order to investigate the relative performance of nucleic acid extraction techniques for molecular testing. Real-time PCR and reverse transcription-PCR crossing threshold (CT) values were used as the metrics for evaluating relative performance. Experimental results were used to develop a guanidinium isothiocyanate-based lysis buffer (UNEX buffer) that enabled effective simultaneous extraction and recovery of DNA and RNA from the suite of study microbes. Procedures for bead beating, nucleic acid purification, and PCR facilitation were also developed and integrated in the protocol. The final lysis buffer and sample preparation procedure was found to be effective for a panel of drinking water and source water concentrates when compared to commercial nucleic acid extraction kits. The UNEX buffer-based extraction protocol enabled PCR detection of six study microbes, in 100 L finished water samples from four drinking water treatment facilities, within three CT values (i.e., within 90% difference) of the reagent-grade water control. The results from this study indicate that this newly formulated lysis buffer and sample preparation procedure can be useful for standardized molecular testing of drinking and environmental waters. PMID:26016775

  4. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss

    PubMed Central

    Vitello, Dominic J.; Ripper, Richard M.; Fettiplace, Michael R.; Weinberg, Guy L.; Vitello, Joseph M.

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R 2 = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R 2 value was 0.1767. Conclusions. The R 2 value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water. PMID:26464949

  5. NMR spectroscopy and chemometrics to evaluate different processing of coconut water.

    PubMed

    Sucupira, N R; Alves Filho, E G; Silva, L M A; de Brito, E S; Wurlitzer, N J; Sousa, P H M

    2017-02-01

    NMR and chemometrics was applied to understand the variations in chemical composition of coconut water under different processing. Six processing treatments were applied to coconut water and analyzed: two control (with and without sulphite), and four samples thermally processed at 110°C and 136°C (with and without sulphite). Samples processed at lower temperature and without sulphite presented pink color under storage. According to chemometrics, samples processed at higher temperature exhibited lower levels of glucose and malic acid. Samples with sulphite processed at 136°C presented lower amount of sucrose, suggesting the degradation of the carbohydrates after harshest thermal treatment. Samples with sulphite and processed at lower temperature showed higher concentration of ethanol. However, no significant changes were verified in coconut water composition as a whole. Sulphite addition and the temperature processing to 136°C were effective to prevent the pinking and to maintain the levels of main organic compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Present-day monitoring underestimates the risk of exposure to pathogenic bacteria from cold water storage tanks

    PubMed Central

    2018-01-01

    Water-borne bacteria, found in cold water storage tanks, are causative agents for various human infections and diseases including Legionnaires’ disease. Consequently, regular microbiological monitoring of tank water is undertaken as part of the regulatory framework used to control pathogenic bacteria. A key assumption is that a small volume of water taken from under the ball valve (where there is easy access to the stored water) will be representative of the entire tank. To test the reliability of this measure, domestic water samples taken from different locations of selected tanks in London properties between November 2015 and July 2016 were analysed for TVCs, Pseudomonas and Legionella at an accredited laboratory, according to regulatory requirements. Out of ~6000 tanks surveyed, only 15 were selected based on the ability to take a water sample from the normal sampling hatch (located above the ball valve) and from the far end of the tank (usually requiring disassembly of the tank lid with risk of structural damage), and permission being granted by the site manager to undertake the additional investigation and sampling. Despite seasonal differences in water temperature, we found 100% compliance at the ball valve end. In contrast, 40% of the tanks exceeded the regulatory threshold for temperature at the far end of the tank in the summer months. Consequently, 20% of the tanks surveyed failed to trigger appropriate regulatory action based on microbiological analyses of the water sample taken under the ball valve compared to the far end sample using present-day standards. These data show that typical water samples collected for routine monitoring may often underestimate the microbiological status of the water entering the building, thereby increasing the risk of exposure to water bourne pathogens with potential public health implications. We propose that water storage tanks should be redesigned to allow access to the far end of tanks for routine monitoring purposes, and that water samples used to ascertain the regulatory compliance of stored water in tanks should be taken at the point at which water is abstracted for use in the building. PMID:29649274

  7. Hydrological, water-quality, and ecological data for streams in Independence, Missouri, June 2005 through September 2013

    USGS Publications Warehouse

    Niesen, Shelley L.; Christensen, Eric D.

    2015-01-01

    Water-quality, hydrological, and ecological data collected from June 2005 through September 2013 from the Little Blue River and smaller streams within the City of Independence, Missouri, are presented in this report. These data were collected as a part of an ongoing cooperative study between the U.S. Geological Survey and the City of Independence Water Pollution Control Department to characterize the water quality and ecological condition of Independence streams. The quantities, sources of selected constituents, and processes affecting water quality and aquatic life were evaluated to determine the resulting ecological condition of streams within Independence. Data collected for this study fulfill the municipal separate sewer system permit requirements for the City of Independence and can be used to provide a baseline with which city managers can determine the effectiveness of current (2014) and future best management practices within Independence. Continuous streamflow and water-quality data, collected during base flow and stormflow, included physical and chemical properties, inorganic constituents, common organic micro-constituents, pesticides in streambed sediment and surface water, fecal indicator bacteria and microbial source tracking data, and suspended sediment. Dissolved oxygen, pH, specific conductance, water temperature, and turbidity data were measured continuously at seven sites within Independence. Base-flow and stormflow samples were collected at eight gaged and two ungaged sites. Fecal sources samples were collected for reference for microbial source tracking, and sewage influent samples were collected as additional source samples. Dry-weather screening was done on 11 basins within Independence to identify potential contaminant sources to the streams. Benthic macroinvertebrate community surveys and habitat assessments were done on 10 stream sites and 2 comparison sites outside the city. Sampling and laboratory procedures and quality-assurance and quality-control methods used in data collection for this study are described in this report.

  8. Concentration data for anthropogenic organic compounds in ground water, surface water, and finished water of selected community water systems in the United States, 2002-05

    USGS Publications Warehouse

    Carter, Janet M.; Delzer, Gregory C.; Kingsbury, James A.; Hopple, Jessica A.

    2007-01-01

    The National Water-Quality Assessment Program of the U.S. Geological Survey began implementing Source Water-Quality Assessments (SWQAs) in 2001 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems (CWSs) in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water), and finished water is the water that is treated and ready to be delivered to consumers. Finished water is collected before entering the distribution system. SWQA studies are conducted in two phases, and the objectives of SWQA studies are twofold: (1) to determine the occurrence and, for rivers, seasonal changes in concentrations of a broad list of anthropogenic organic compounds (AOCs) in aquifers and rivers that have some of the largest withdrawals for drinking-water supply (phase 1), and (2) for those AOCs found to occur most frequently in source water, characterize the extent to which these compounds are present in finished water (phase 2). These objectives were met for SWQA studies by collecting ground-water and surface-water (source) samples and analyzing these samples for 258 AOCs during phase 1. Samples from a subset of wells and surface-water sites located in areas with substantial agricultural production in the watershed were analyzed for 19 additional AOCs, for a total of 277 compounds analyzed for SWQA studies. The 277 compounds were classified according to the following 13 primary use or source groups: (1) disinfection by-products; (2) fumigant-related compounds; (3) fungicides; (4) gasoline hydrocarbons, oxygenates, and oxygenate degradates; (5) herbicides and herbicide degradates; (6) insecticides and insecticide degradates; (7) manufacturing additives; (8) organic synthesis compounds; (9) pavement- and combustion-derived compounds; (10) personal care and domestic use products; (11) plant- or animal-derived biochemicals; (12) refrigerants and propellants; and (13) solvents. Source and finished water samples were collected during phase 2 and analyzed for constituents that were detected frequently during phase 1. This report presents concentration data for AOCs in ground water, surface water, and finished water of CWSs sampled for SWQA studies during 2002-05. Specifically, this report presents the analytical results of samples collected during phase 1 including (1) samples from 221 wells that were analyzed for 258 AOCs; (2) monthly samples from 9 surface-water sites that were analyzed for 258 AOCs during phase 1; and (3) samples from a subset of the wells and surface-water sites located in areas with substantial agricultural production that were analyzed for 3 additional pesticides and 16 pesticide degradates. Samples collected during phase 2 were analyzed for selected AOCs that were detected most frequently in source water during phase 1 sampling; analytical results for phase 2 are presented for (1) samples of source water and finished water from 94 wells; and (2) samples of source water and finished water samples that were collected monthly and during selected flow conditions at 8 surface-water sites. Results of quality-assurance/quality-control samples collected for SWQA studies during 2002-05 also are presented.

  9. Chemical and microbiological water quality of subsurface agricultural drains during a field trial of liquid dairy manure effluent application rate and varying tillage practices, Upper Tiffin Watershed, southeastern Michigan

    USGS Publications Warehouse

    Haack, Sheridan Kidd; Duris, Joseph W.

    2008-01-01

    A field trial was done in the Upper Tiffin River Watershed, in southeastern Michigan, to determine the influence of liquid dairy manure effluent (LDME) management practices on the quality of agricultural subsurface-drain water. Samples from subsurface drains were analyzed for nutrients, fecal-coliform and Escherichia coli (E. coli) bacteria, antibiotics, chemicals typically detected in wastewater, and the occurrence of genes indicating the presence of shiga-toxin-producing E. coli, or of bovine-specific Bacteroidetes bacteria. Samples were collected from November 2, 2006, to March 20, 2007, from eight subsurface drains under field plots that received no LDME and no tillage (controls) or received 4,000 or 8,000 gallons per acre (gal/acre) of LDME and either no tillage or two different types of tillage. The two types of tillage tested were (1) ground-driven, rotary, subsurface cultivation and (2) rolling-tine aeration. Samples were collected before LDME application and at 4 hours, and 1, 2, 6, 7, and 14 days post-application. Nutrient concentrations were high in subsurface-drain water throughout the field-trial period and could not be attributed to the field-trial LDME application. Of the 59 drain-water samples, including those collected before LDME application and control samples for each date, 56 had concentrations greater than the U.S. Environmental Protection Agency (USEPA), Ecoregion VI recommended surface-water criterion for total phosphorus, and all samples had concentrations greater than the recommended total nitrogen criterion. Nitrate + nitrite nitrogen concentration exceeded 20 milligrams per liter for every sample and contributed most to the total nitrogen concentrations. Substantial increases in drain-water concentrations of organic and ammonia nitrogen and total phosphorus were found for all treatments, including controls, at 14 days post-application after 0.84 inch of rainfall over 2 days. E. coli concentrations exceeded the USEPA recreational-water-quality single-sample criterion of 235 colony forming units per 100 milliliters in only 3 of 56 samples. Of these three samples, two were collected within 1 day post-LDME application from the treatment receiving 8,000 gal/acre LDME with no tillage (NT8000). The third sample was from the rolling-tine aerator treatment with 4,000 gal/acre LDME application rate after the first significant rainfall. Two wastewater chemicals and two bacterial genes (eaeA and stx1) detected in the LDME, but absent in field blank or pre-application samples, were detected in the 4-hour or 1-day postapplication NT8000 samples. No LDME-associated chemicals were detected in later samples from the NT8000 treatment, and none were detected in samples from other treatments after the first significant rainfall. Results of this field trial were somewhat equivocal with respect to the influence of LDME concentration and tillage practices on subsurface-drain water quality, both immediately after LDME application and in the longer term, after significant rainfall. Interpretation of study findings is limited by the fact that treatments were not replicated, and flow rate or discharge from the subsurface drains was not measured. Nevertheless, study results provide useful information about nutrient and bacteria concentrations in subsurface drains during the non-growing season. In addition, study results demonstrate some potential for the use of chemical and microbiological indicators of LDME transport to subsurface drains.

  10. Integrated Microfluidic Gas Sensors for Water Monitoring

    NASA Technical Reports Server (NTRS)

    Zhu, L.; Sniadecki, N.; DeVoe, D. L.; Beamesderfer, M.; Semancik, S.; DeVoe, D. L.

    2003-01-01

    A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

  11. Hydrologic and environmental controls on uranium-series and strontium isotope ratios in a natural weathering environment

    NASA Astrophysics Data System (ADS)

    White, A. M.; Ma, L.; Moravec, B. G.; McIntosh, J. C.; Chorover, J.

    2017-12-01

    In a remote, volcanic headwater catchment of the Jemez River Basin Critical Zone Observatory (JRB-CZO) in NM, stable water isotopes and solute chemistry have shown that snowmelt infiltrates and is stored before later discharging into springs and streams via subsurface flowpaths that vary seasonally. Therefore, water-rock reactions are also expected to change with season as hydrologic flowpaths transport water, gases and solutes through different biogeochemical conditions, rock types and fracture networks. Uranium-series isotopes have been shown to be a novel tracer of water-rock reactions and source water contributions while strontium isotopes are frequently used as indicators of chemical weathering and bedrock geology. This study combines both isotopes to understand how U and Sr isotope signatures evolve through the Critical Zone (CZ). More specifically, this work examines the relationship between seasonality, water transit time (WTT), and U-series and Sr isotopes in stream and spring waters from three catchments within the JRB-CZO, as well as lithology, rock type and CZ structure in solid phase cores. Samples from ten springs with known WTTs were analyzed for U and Sr isotopes to determine the effect of WTT on the isotopic composition of natural waters. Results suggest that WTT alone cannot explain the variability of U and Sr isotopes in JRB-CZO springs. Stream samples were also collected across two water years to establish how seasonality controls surface water isotopic composition. U and Sr isotope values vary with season, consistent with a previous study from the La Jara catchment; however, this study revealed that these changes do not show a systematic pattern among the three catchments suggesting that differences in the mineralogy and structure of the deep CZ in individual catchments, and partitioning of water along deep vs surficial and fracture vs matrix flow paths, likely also control isotopic variability. The distribution of U-series and Sr isotopes in core samples with depth shows distinct weathering profiles with variable 234U/238U activity and Sr isotope ratios. Comparison of the isotopic composition of cores and groundwaters from similar depths, as well as surface waters in the JRB-CZO will be vital for the characterization of hydrogeologic controls on isotopic composition in this complex terrain.

  12. DEVELOPMENT OF VIRAL INTERNAL CONTROLS FOR THE ASSESSMENT OF INHIBITOR REMOVAL FROM ENVIRONMENTAL WATER SAMPLES.

    EPA Science Inventory

    The presence of human enteric viruses in drinking water is of public health concern. It is therefore important to be able to reliably detect these viruses in contaminating water sources. Cell culture methods are time consuming and also not all enteric viruses can currently be p...

  13. [Simultaneous determination of 22 typical pharmaceuticals and personal care products in environmental water using ultra performance liquid chromatography- triple quadrupole mass spectrometry].

    PubMed

    Wu, Chunying; Gu, Feng; Bai, Lu; Lu, Wenlong

    2015-08-01

    An analytical method for simultaneous determination of 22 typical pharmaceuticals and personal care products (PPCPs) in environmental water samples was developed by ultra performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS). An Oasis HLB solid phase extraction cartridge, methanol as washing solution, water containing 0. 1% formic acid-methanol (7:3, v/v) as the mobile phases were selected for sample pretreatment and chromatographic separation. Based on the optimized sample pretreatment procedures and separation condition, the target recoveries ranged from 73% to 125% in water with the relative standard deviations ( RSDs) from 8.8% to 17.5%, and the linear ranges were from 2 to 2 000 µg/L with correlation coefficients (R2) not less than 0.997. The method can be applied to simultaneous determination of the 22 typical PPCPs in environmental water samples because of its low detection limits and high recoveries. It can provide support and help for the related research on water environmental risk assessment and control of the micro-organic pollutants.

  14. Proceedings Abstracts: American Water Resources Association's Symposium on the National Water-Quality Assessment (NAWQA) Program--November 7-9, 1994, Chicago, Illinois

    USGS Publications Warehouse

    Sorenson, Stephen K.

    1994-01-01

    Approximately 418,000 pounds of triazine herbicides are applied annually to control weeds in crops grown in the Albemarle-Pamilico Sound drainage basin, located in North Carolina and Virginia. An enzyme-linked immunosorbent assay was used to detect concentrations of total triazine herbicides in streams draining into Albemarle-Pamlico Sound. Water samples were collected in May and June during the application of triazine herbicides and in early September during low streamflows at approximately 40 sites on streams in the Coastal Plain and Piedmont Physiographic Provinces. Triazine concentrations exceeded 0.2 ?g/L (micrograms per liter) in 67 percent of the water samples collected In June, and 13 percent of the water samples exceeded 0.2 ?g/L in September during low streamflows. The enzyme-linked immunosorbent assay for total triazine herbicides provides a low-cost and rapid analytical method for screening water samples prior to sending them to a laboratory and for semiquantitatively assessing seasonal concentrations of triazine herbicides in streams throughout a large region.

  15. A level change in mutagenicity of Japanese tap water over the past 12 yr.

    PubMed

    Takanashi, Hirokazu; Kishida, Misako; Nakajima, Tsunenori; Ohki, Akira; Akiba, Michihiro

    2011-05-01

    A relative comparison study of mutagenicity in Japanese tap water was conducted for 1993 and 2005 surveys. It intended to assess the effects of advanced water treatment installations to water works, improvement of raw water quality and improvement of residual HOCl concentration controlling. Sampling points (taps) were the same in both surveys. The results of 245 samples obtained by the Ames Salmonella mutagenicity test (Ames test) were analyzed. The Ames tests were conducted by using Salmonella typhimurium TA98 and TA100 strains with and without exogenous activation (S9). With the exception of TA100-S9, the other conditions needed no discussion as a factor in the mutagenicity level change. The average mutagenicity in 1993 and 2005 under the conditions of TA100-S9 were 2600 and 1100 net revertantL(-1), respectively. This indicated that the mutagenicity level of Japanese tap water decreased during the 12-yr period. Particularly a remarkable decrease in mutagenicity was observed in the water works where the advanced water treatments were installed during the 12-yr period. The advanced water treatments were effective in decreasing the mutagenicity of tap water. Mutagenicity also decreased in the water works with conventional water treatments; the improvement of residual HOCl concentration controlling was also considered to be effective in decreasing the mutagenicity of tap water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Microprocessor controlled anodic stripping voltameter for trace metals analysis in tap water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clem, R.G.; Park, F.W.; Kirsten, F.A.

    1981-04-01

    The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time; a rotating cell for efficient oxygen removal and amalgam formation; and, a magnetic tape which can be used for data storage. Analysis time can be as short as 10 to 15 minutes. The stripping analysis is based on a pre-measurement step during which the metals from a water sample are concentratedmore » into a thin mercury film by deposition from an acetate solution of pH 4.5. The concentrated metals are then electrochemically dissolved from the film by application of a linearly increasing anodic potential. Typical peak-shaped curves are obtained. The heights of these curves are related to the concentration of metals in the water by calibration data. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1 to 1000 ..mu..g/L Cu, 1 to 2 ..mu..g/L Pb for ten samples of Seattle, Washington tap water. Recommendations are given for a next generation instrument system.« less

  17. Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?

    PubMed

    Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino

    2010-12-01

    Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.

  18. Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-11-01

    Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less

  19. A large and persistent outbreak of typhoid fever caused by consuming contaminated water and street-vended beverages: Kampala, Uganda, January - June 2015.

    PubMed

    Kabwama, Steven Ndugwa; Bulage, Lilian; Nsubuga, Fred; Pande, Gerald; Oguttu, David Were; Mafigiri, Richardson; Kihembo, Christine; Kwesiga, Benon; Masiira, Ben; Okullo, Allen Eva; Kajumbula, Henry; Matovu, Joseph K B; Makumbi, Issa; Wetaka, Milton; Kasozi, Sam; Kyazze, Simon; Dahlke, Melissa; Hughes, Peter; Sendagala, Juliet Nsimire; Musenero, Monica; Nabukenya, Immaculate; Hill, Vincent R; Mintz, Eric; Routh, Janell; Gómez, Gerardo; Bicknese, Amelia; Zhu, Bao-Ping

    2017-01-05

    On 6 February 2015, Kampala city authorities alerted the Ugandan Ministry of Health of a "strange disease" that killed one person and sickened dozens. We conducted an epidemiologic investigation to identify the nature of the disease, mode of transmission, and risk factors to inform timely and effective control measures. We defined a suspected case as onset of fever (≥37.5 °C) for more than 3 days with abdominal pain, headache, negative malaria test or failed anti-malaria treatment, and at least 2 of the following: diarrhea, nausea or vomiting, constipation, fatigue. A probable case was defined as a suspected case with a positive TUBEX® TF test. A confirmed case had blood culture yielding Salmonella Typhi. We conducted a case-control study to compare exposures of 33 suspected case-patients and 78 controls, and tested water and juice samples. From 17 February-12 June, we identified 10,230 suspected, 1038 probable, and 51 confirmed cases. Approximately 22.58% (7/31) of case-patients and 2.56% (2/78) of controls drank water sold in small plastic bags (OR M-H  = 8.90; 95%CI = 1.60-49.00); 54.54% (18/33) of case-patients and 19.23% (15/78) of controls consumed locally-made drinks (OR M-H  = 4.60; 95%CI: 1.90-11.00). All isolates were susceptible to ciprofloxacin and ceftriaxone. Water and juice samples exhibited evidence of fecal contamination. Contaminated water and street-vended beverages were likely vehicles of this outbreak. At our recommendation authorities closed unsafe water sources and supplied safe water to affected areas.

  20. Riparian control of stream-water chemistry: Implications for hydrochemical basin models

    USGS Publications Warehouse

    Hooper, R.P.; Aulenbach, Brent T.; Burns, Douglas A.; McDonnell, J.; Freer, J.; Kendall, C.; Beven, K.

    1998-01-01

    End-member mixing analysis has been used to determine the hydrological structure for basin hydrochemical models at several catchments. Implicit in this use is the assumption that controlling end members have been identified, and that these end members represent distinct landscape locations. At the Panola Mountain Research Watershed, the choice of controlling end members was supported when a large change in the calcium and sulphate concentration of one of the end members was reflected in the stream water. More extensive sampling of groundwater and soil water indicated, however, that the geographic extent of the contributing end members was limited to the riparian zone. Hillslope solutions were chemically distinct from the riparian solutions and did not appear to make a large contribution to streamflow. The dominant control of the riparian zone on stream-water chemistry suggests that hydrological flow paths cannot be inferred from stream-water chemical dynamics.

  1. Water quality data for selected wells in the Coastal Plain of New Jersey, 1996-98

    USGS Publications Warehouse

    Hibbs, Kathleen L.; Stackelberg, Paul E.; Kauffman, Leon J.; Ayers, Mark A.

    2001-01-01

    Water-quality data were collected during 1996-98 for 217 wells in New Jersey and 3 wells in New York as part of the U. S. Geological Survey's National Water Quality Assessment Program. Samples were collected for five ground-water surveys that were designed to assess water quality in major aquifer systems, with an emphasis on recently recharged (shallow) ground water associated with present and recent human activities. This report (1) summarizes the hydrogeologic framework in the areas of data collection; (2) describes the objectives and procedures for designing each ground-water survey; (3) summarizes the procedures and protocols for data collec-tion, analysis, and quality control; and (4) lists the concentrations of inorganic constituents, volatile organic compounds, pesticides, nutrients, and trace elements present in the ground-water samples.

  2. Air and water quality monitor assessment of life support subsystems

    NASA Technical Reports Server (NTRS)

    Whitley, Ken; Carrasquillo, Robyn L.; Holder, D.; Humphries, R.

    1988-01-01

    Preprotype air revitalization and water reclamation subsystems (Mole Sieve, Sabatier, Static Feed Electrolyzer, Trace Contaminant Control, and Thermoelectric Integrated Membrane Evaporative Subsystem) were operated and tested independently and in an integrated arrangement. During each test, water and/or gas samples were taken from each subsystem so that overall subsystem performance could be determined. The overall test design and objectives for both subsystem and integrated subsystem tests were limited, and no effort was made to meet water or gas specifications. The results of chemical analyses for each of the participating subsystems are presented along with other selected samples which were analyzed for physical properties and microbiologicals.

  3. Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment.

    PubMed

    Booij, Kees; Robinson, Craig D; Burgess, Robert M; Mayer, Philipp; Roberts, Cindy A; Ahrens, Lutz; Allan, Ian J; Brant, Jan; Jones, Lisa; Kraus, Uta R; Larsen, Martin M; Lepom, Peter; Petersen, Jördis; Pröfrock, Daniel; Roose, Patrick; Schäfer, Sabine; Smedes, Foppe; Tixier, Céline; Vorkamp, Katrin; Whitehouse, Paul

    2016-01-05

    We reviewed compliance monitoring requirements in the European Union, the United States, and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic, and evaluated if these are met by passive sampling methods for nonpolar compounds. The strengths and shortcomings of passive sampling are assessed for water, sediments, and biota. Passive water sampling is a suitable technique for measuring concentrations of freely dissolved compounds. This method yields results that are incompatible with the EU's quality standard definition in terms of total concentrations in water, but this definition has little scientific basis. Insufficient quality control is a present weakness of passive sampling in water. Laboratory performance studies and the development of standardized methods are needed to improve data quality and to encourage the use of passive sampling by commercial laboratories and monitoring agencies. Successful prediction of bioaccumulation based on passive sampling is well documented for organisms at the lower trophic levels, but requires more research for higher levels. Despite the existence of several knowledge gaps, passive sampling presently is the best available technology for chemical monitoring of nonpolar organic compounds. Key issues to be addressed by scientists and environmental managers are outlined.

  4. Sources, transformations, and hydrological processes that control stream nitrate and dissolved organic matter concentrations during snowmelt in an upland forest

    Treesearch

    Stephen D. Sebestyen; Elizabeth W. Boyer; James B. Shanley; Carol Kendall; Daniel H. Doctor; George R. Aiken; Nobuhito Ohte

    2008-01-01

    We explored catchment processes that control stream nutrient concentrations at an upland forest in northeastern Vermont, USA, where inputs of nitrogen via atmospheric deposition are among the highest in the nation and affect ecosystem functioning. We traced sources of water, nitrate, and dissolved organic matter (DOM) using stream water samples collected at high...

  5. Monitoring the aftermath of Flint drinking water contamination crisis: Another case of sampling bias?

    PubMed

    Goovaerts, Pierre

    2017-07-15

    The delay in reporting high levels of lead in Flint drinking water, following the city's switch to the Flint River as its water supply, was partially caused by the biased selection of sampling sites away from the lead pipe network. Since Flint returned to its pre-crisis source of drinking water, the State has been monitoring water lead levels (WLL) at selected "sentinel" sites. In a first phase that lasted two months, 739 residences were sampled, most of them bi-weekly, to determine the general health of the distribution system and to track temporal changes in lead levels. During the same period, water samples were also collected through a voluntary program whereby concerned citizens received free testing kits and conducted sampling on their own. State officials relied on the former data to demonstrate the steady improvement in water quality. A recent analysis of data collected by voluntary sampling revealed, however, an opposite trend with lead levels increasing over time. This paper looks at potential sampling bias to explain such differences. Although houses with higher WLL were more likely to be sampled repeatedly, voluntary sampling turned out to reproduce fairly well the main characteristics (i.e. presence of lead service lines (LSL), construction year) of Flint housing stock. State-controlled sampling was less representative; e.g., sentinel sites with LSL were mostly built between 1935 and 1950 in lower poverty areas, which might hamper our ability to disentangle the effects of LSL and premise plumbing (lead fixtures and pipes present within old houses) on WLL. Also, there was no sentinel site with LSL in two of the most impoverished wards, including where the percentage of children with elevated blood lead levels tripled following the switch in water supply. Correcting for sampling bias narrowed the gap between sampling programs, yet overall temporal trends are still opposite. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Microbiological test results of the environmental control and life support systems vapors compression distillation subsystem recycle tank components following various pretreatment protocols

    NASA Technical Reports Server (NTRS)

    Huff, Tim

    1993-01-01

    Microbiological samples were collected from the recycle tank of the vapor compression distillation (VCD) subsystem of the water recovery test at NASA MSFC following a 68-day run. The recycle tank collects rejected urine brine that was pretreated with a commercially available oxidant (Oxone) and sulfuric acid and pumps it back to the processing component of the VCD. Samples collected included a water sample and two swab samples, one from the particulate filter surface and a second from material floating on the surface of the water. No bacteria were recovered from the water sample. Both swab samples contained a spore-forming bacterium, Bacillus insolitus. A filamentous fungus was isolated from the floating material. Approximately 1 month after the pretreatment chemicals were changed to sodium hypochlorite and sulfuric acid, a swab of the particulate filter was again analyzed for microbial content. One fungus was isolated, and spore-forming bacteria were observed. These results indicate the inability of these pretreatments to inhibit surface attachment. The implications of the presence of these organisms are discussed.

  7. Hydrochemical modelling of water quality in terms of emerging micropollutants in Mpumalanga, Gauteng and North West Provinces

    NASA Astrophysics Data System (ADS)

    Wanda, Elijah M. M.; Mamba, Bhekie B.; Msagati, Titus A. M.

    2017-08-01

    Emerging micropollutants (EMPs) are ubiquitous in aquatic systems and are associated with a wide range of eco-toxicological effects worldwide. There remains a lack of scientific understanding of the major underlying hydrochemical factors behind variations in concentration heterogeneities of EMPs in time and space. This study was therefore conducted to determine major hydrochemical processes controlling water quality and the occurrence of EMPs mainly, carbamazepine (CBZ), tonalide (AHTN), galaxolide (HHCB), caffeine (CAF), technical 4-nonylphenol (NP) and bisphenol A (BPA) in water from Mpumalanga, Gauteng and North West Provinces in South Africa. Grab water samples were collected bi-monthly between June 2014 and April 2016 from 44 water sources using standard sampling procedures. BPA, NP, CAF, HHCB, AHTN, CBZ were extracted, cleaned and enriched using autotrace-SPE at neutral pH and analyzed using GC × GC-TOFMS. Kruskal Wallis-test was used to test for temporal variations in occurrence of the analytes. The Geochemist's Workbench® Release 11 software, Surfer Golden Graphics for surface mapping, PHREEQC software and bivariate ion plots were used determine the major hydrogeochemical processes. The mean concentrations of EMPs varied from 3.48 μg/L for CAF to 421.53 μg/L for HHCB. Although the Kruskal Wallis test revealed no any statistically significant temporal variations in concentrations of the analytes in water samples at 95% confidence level, their occurrence and distribution vary spatially with BPA being the most widely distributed EMP and was present in 62% of the sampled sites. Municipal waste water inputs, agricultural pollution, ion-exchange reactions, carbonate and silicate weathering were the major processes controlling water quality in the study area. This study may assist water resource managers to ably address and manage water pollution resulting from a number of natural and anthropogenic hydrochemical processes in the study area.

  8. Determination of secondary and tertiary amines as N-nitrosamine precursors in drinking water system using ultra-fast liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Qihua; Shi, Honglan; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Timmons, Terry; Jiang, Hua

    2015-01-01

    N-Nitrosamines are potent mutagenic and carcinogenic emerging water disinfection by-products (DBPs). The most effective strategy to control the formation of these DBPs is minimizing their precursors from source water. Secondary and tertiary amines are dominating precursors of N-nitrosamines formation during drinking water disinfection process. Therefore, the screening and removal of these amines in source water are very essential for preventing the formation of N-nitrosamines. A rapid, simple, and sensitive ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed in this study to determine seven amines, including dimethylamine, ethylmethylamine, diethylamine, dipropylamine, trimethylamine, 3-(dimethylaminomethyl)indole, and 4-dimethylaminoantipyrine, as major precursors of N-nitrosamines in drinking water system. No sample preparation process is needed except a simple filtration. Separation and detection can be achieved in 11 min per sample. The method detection limits of selected amines are ranging from 0.02 μg/L to 1 μg/L except EMA (5 μg/L), and good calibration linearity was achieved. The developed method was applied to determine the selected precursors in source water and drinking water samples collected from Midwest area of the United States. In most of water samples, the concentrations of selected precursors of N-nitrosamines were below their method detection limits. Dimethylamine was detected in some of water samples at the concentration up to 25.4 μg/L. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The spatial variability of water chemistry and DOC in bog pools: the importance of slope position, diurnal turnover and pool type

    NASA Astrophysics Data System (ADS)

    Holden, Joseph; Turner, Ed; Baird, Andy; Beadle, Jeannie; Billett, Mike; Brown, Lee; Chapman, Pippa; Dinsmore, Kerry; Dooling, Gemma; Grayson, Richard; Moody, Catherine; Gee, Clare

    2017-04-01

    We have previously shown that marine influence is an important factor controlling regional variability of pool water chemistry in blanket peatlands. Here we examine within-site controls on pool water chemistry. We surveyed natural and artificial (restoration sites) bog pools at blanket peatland sites in northern Scotland and Sweden. DOC, pH, conductivity, dissolved oxygen, temperature, cations, anions and absorbance spectra from 220-750nm were sampled. We sampled changes over time but also conducted intensive spatial surveys within individual pools and between pools on the same sampling days at individual study sites. Artificial pools had significantly greater DOC concentrations and different spectral absorbance characteristics when compared to natural pools at all sites studied. Within-pool variability in water chemistry tended to be small, even for very large pools ( 400 m2), except where pools had a layer of loose, mobile detritus on their beds. In these instances rapid changes took place between the overlying water column and the mobile sediment layer wherein dissolved oxygen concentrations dropped from values of around 12-10 mg/L to values less than 0.5 mg/L over just 2-3 cm of the depth profile. Such strong contrasts were not observed for pools which had a hard peat floor and which lacked a significant detritus layer. Strong diurnal turnover occurred within the pools on summer days, including within small, shallow pools (e.g. < 30 cm deep, 1 m2 area). For many pools on these summer days there was an evening spike in dissolved oxygen concentrations which originated at the surface and was then cycled downwards as the pool surface waters cooled. Slope location was a significant control on several pool water chemistry variables including pH and DOC concentration with accumulation (higher concentrations) in pools that were located further downslope in both natural and artificial pool systems. These processes have important implications for our interpretation of water chemistry and gas flux data from pool systems, how we design our sampling strategies and how we upscale results.

  10. Pathogenic waterborne free-living amoebae: An update from selected Southeast Asian countries

    PubMed Central

    Abdul Majid, Mohamad Azlan; Mahboob, Tooba; Mong, Brandon G. J.; Jaturas, Narong; Richard, Reena Leeba; Tian-Chye, Tan; Phimphila, Anusorn; Mahaphonh, Panomphanh; Aye, Kyaw Nyein; Aung, Wai Lynn; Chuah, Joon; Ziegler, Alan D.; Yasiri, Atipat; Sawangjaroen, Nongyao; Lim, Yvonne A. L.; Nissapatorn, Veeranoot

    2017-01-01

    Data on the distribution of free-living amoebae is still lacking especially in Southeast Asian region. The aquatic environment revealed a high occurrence of free-living amoebae (FLA) due to its suitable condition and availability of food source, which subsequently causes infection to humans. A total of 94 water samples consisted of both treated and untreated from Laos (31), Myanmar (42), and Singapore (21) were investigated for the presence of pathogenic FLA. Each water sample was filtered and cultured onto non-nutrient agar seeded with live suspension of Escherichia coli and incubated at room temperature. Morphological identification was conducted for both trophozoites and cysts via microscopic stains (Giemsa and immunofluorescence). The presence of Naegleria-like structures was the most frequently encountered in both treated and untreated water samples, followed by Acanthamoeba-like and Vermamoeba-like features. To identify the pathogenic isolates, species-specific primer sets were applied for molecular identification of Acanthamoeba, Naegleria, and Vermamoeba. The pathogenic species of Acanthamoeba lenticulata and A. triangularis were detected from untreated water samples, while Vermamoeba vermiformis was found in both treated and untreated water samples. Our results suggested that poor water quality as well as inadequate maintenance and treatment might be the cause of this alarming problem since chlorine disinfection is ineffective in eradicating these amoebas in treated water samples. Regular monitoring and examination of water qualities are necessary in order to control the growth, hence, further preventing the widespread of FLA infections among the public. PMID:28212409

  11. Pathogenic waterborne free-living amoebae: An update from selected Southeast Asian countries.

    PubMed

    Abdul Majid, Mohamad Azlan; Mahboob, Tooba; Mong, Brandon G J; Jaturas, Narong; Richard, Reena Leeba; Tian-Chye, Tan; Phimphila, Anusorn; Mahaphonh, Panomphanh; Aye, Kyaw Nyein; Aung, Wai Lynn; Chuah, Joon; Ziegler, Alan D; Yasiri, Atipat; Sawangjaroen, Nongyao; Lim, Yvonne A L; Nissapatorn, Veeranoot

    2017-01-01

    Data on the distribution of free-living amoebae is still lacking especially in Southeast Asian region. The aquatic environment revealed a high occurrence of free-living amoebae (FLA) due to its suitable condition and availability of food source, which subsequently causes infection to humans. A total of 94 water samples consisted of both treated and untreated from Laos (31), Myanmar (42), and Singapore (21) were investigated for the presence of pathogenic FLA. Each water sample was filtered and cultured onto non-nutrient agar seeded with live suspension of Escherichia coli and incubated at room temperature. Morphological identification was conducted for both trophozoites and cysts via microscopic stains (Giemsa and immunofluorescence). The presence of Naegleria-like structures was the most frequently encountered in both treated and untreated water samples, followed by Acanthamoeba-like and Vermamoeba-like features. To identify the pathogenic isolates, species-specific primer sets were applied for molecular identification of Acanthamoeba, Naegleria, and Vermamoeba. The pathogenic species of Acanthamoeba lenticulata and A. triangularis were detected from untreated water samples, while Vermamoeba vermiformis was found in both treated and untreated water samples. Our results suggested that poor water quality as well as inadequate maintenance and treatment might be the cause of this alarming problem since chlorine disinfection is ineffective in eradicating these amoebas in treated water samples. Regular monitoring and examination of water qualities are necessary in order to control the growth, hence, further preventing the widespread of FLA infections among the public.

  12. Groundwater-Quality Data in the Antelope Valley Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Schmitt, Stephen J.; Milby Dawson, Barbara J.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 1,600 square-mile Antelope Valley study unit (ANT) was investigated from January to April 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within ANT, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 57 wells in Kern, Los Angeles, and San Bernardino Counties. Fifty-six of the wells were selected using a spatially distributed, randomized, grid-based method to provide statistical representation of the study area (grid wells), and one additional well was selected to aid in evaluation of specific water-quality issues (understanding well). The groundwater samples were analyzed for a large number of organic constituents (volatile organic compounds [VOCs], gasoline additives and degradates, pesticides and pesticide degradates, fumigants, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents (gross alpha and gross beta radioactivity, radium isotopes, and radon-222). Naturally occurring isotopes (strontium, tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 239 constituents and water-quality indicators (field parameters) were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at 12 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compoundsThis study did not evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with drinking water standards. Most constituents that were detected in groundwater samples were found at concentrations below drinking-water thresholds. Volatile organic compounds (VOCs) were detected in about one-half of the samples and pesticides detected in about one-third of the samples; all detections of these constituents were below health-based thresholds. Most detections of trace elements and nutrients in samples from ANT wells were below health-based thresholds. Exceptions include: one detection of nitrite plus nitr

  13. Community-based wastewater treatment systems and water quality of an Indonesian village.

    PubMed

    Lim, H S; Lee, L Y; Bramono, S E

    2014-03-01

    This paper examines the impact of community-based water treatment systems on water quality in a peri-urban village in Yogyakarta, Indonesia. Water samples were taken from the wastewater treatment plants (WWTPs), irrigation canals, paddy fields and wells during the dry and wet seasons. The samples were tested for biological and chemical oxygen demand, nutrients (ammonia, nitrate, total nitrogen and total phosphorus) and Escherichia coli. Water quality in this village is affected by the presence of active septic tanks, WWTP effluent discharge, small-scale tempe industries and external sources. We found that the WWTPs remove oxygen-demanding wastes effectively but discharged nutrients, such as nitrate and ammonia, into irrigation canals. Irrigation canals had high levels of E. coli as well as oxygen-demanding wastes. Well samples had high E. coli, nitrate and total nitrogen levels. Rainfall tended to increase concentrations of biological and chemical oxygen demand and some nutrients. All our samples fell within the drinking water standards for nitrate but failed the international and Indonesian standards for E. coli. Water quality in this village can be improved by improving the WWTP treatment of nutrients, encouraging more villagers to be connected to WWTPs and controlling hotspot contamination areas in the village.

  14. Evaluation of water quality and hydrogeochemistry of surface and groundwater, Tiruvallur District, Tamil Nadu, India

    NASA Astrophysics Data System (ADS)

    Krishna Kumar, S.; Hari Babu, S.; Eswar Rao, P.; Selvakumar, S.; Thivya, C.; Muralidharan, S.; Jeyabal, G.

    2017-09-01

    Water quality of Tiruvallur Taluk of Tiruvallur district, Tamil Nadu, India has been analysed to assess its suitability in relation to domestic and agricultural uses. Thirty water samples, including 8 surface water (S), 22 groundwater samples [15 shallow ground waters (SW) and 7 deep ground waters (DW)], were collected to assess the various physico-chemical parameters such as Temperature, pH, Electrical conductivity (EC), Total dissolved solids (TDS), cations (Ca, Mg, Na, K), anions (CO3, HCO3, Cl, SO4, NO3, PO4) and trace elements (Fe, Mn, Zn). Various irrigation water quality diagrams and parameters such as United states salinity laboratory (USSL), Wilcox, sodium absorption ratio (SAR), sodium percentage (Na %), Residual sodium carbonate (RSC), Residual Sodium Bicarbonate (RSBC) and Kelley's ratio revealed that most of the water samples are suitable for irrigation. Langelier Saturation Index (LSI) values suggest that the water is slightly corrosive and non-scale forming in nature. Gibbs plot suggests that the study area is dominated by evaporation and rock-water dominance process. Piper plot indicates the chemical composition of water, chiefly controlled by dissolution and mixing of irrigation return flow.

  15. Identifying Source Water and Flow Paths in a Semi-Arid Watershed

    NASA Astrophysics Data System (ADS)

    Gulvin, C. J.; Miller, S. N.

    2016-12-01

    Processes controlling water delivery to perennial streams in the semi-arid mountain west are poorly understood, yet necessary to characterize water distribution across the landscape and better protect and manage diminishing water resources. Stream water chemistry profiling and hydrograph separation using stable isotopes can help identify source waters. Weekly stream water samples tested for stable water isotope fractionations, and major cations and anions at seven sites collocated with continuously recording stream depth gauges within a small watershed in southeastern Wyoming is a necessary first-step to identifying seasonally changing source water and flow paths. Sample results will help establish appropriate end members for a mixing analysis, as well as, characterize flow path heterogeneity, transit time distributions, and landscape selectively features. Hourly stream sampling during late-summer thunderstorms and rapid spring melt will help demonstrate if and how stream discharge change is affected by the two different events. Soil water and water extracted from tree xylem will help resolve how water is partitioned in the first 10m of the subsurface. In the face of land use change and a growing demand for water in the area, understanding how the water in small mountain streams is sustained is crucial for the future of agriculture, municipal water supplies, and countless ecosystem services.

  16. Ground-Water Quality Data in the Middle Sacramento Valley Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Schmitt, Stephen J.; Fram, Miranda S.; Milby Dawson, Barbara J.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 3,340 square mile Middle Sacramento Valley study unit (MSACV) was investigated from June through September, 2006, as part of the California Groundwater Ambient Monitoring and Assessment (GAMA) program. The GAMA Priority Basin Assessment project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Middle Sacramento Valley study was designed to provide a spatially unbiased assessment of raw ground-water quality within MSACV, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 108 wells in Butte, Colusa, Glenn, Sutter, Tehama, Yolo, and Yuba Counties. Seventy-one wells were selected using a randomized grid-based method to provide statistical representation of the study unit (grid wells), 15 wells were selected to evaluate changes in water chemistry along ground-water flow paths (flow-path wells), and 22 were shallow monitoring wells selected to assess the effects of rice agriculture, a major land use in the study unit, on ground-water chemistry (RICE wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, laboratory matrix spikes) were collected at approximately 10 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the ground-water samples. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most constituents. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and are not indicative of compliance or noncompliance with regulatory thresholds. Most constituents that were detected in ground-water samples were found at concentrations below drinking-water thresholds. VOCs were detected in less than one-third and pesticides and pesticide degradates in just over one-half of the grid wells, and all detections of these constituents in samples from all wells of the MSACV study unit were below health-based thresholds. All detections of trace elements in samples from MSACV grid wells were below health-based thresholds, with the exceptions of arsenic and boro

  17. Determination of tributyltin in whole water matrices under the European Water Framework Directive.

    PubMed

    Richter, Janine; Fettig, Ina; Philipp, Rosemarie; Jakubowski, Norbert; Panne, Ulrich; Fisicaro, Paola; Alasonati, Enrica

    2016-08-12

    Monitoring of water quality is important to control water pollution. Contamination of the aquatic system has a large effect on human health and the environment. Under the European Water Framework Directive (WFD) 2000/60/EC and the related directive on environmental quality standards (EQS) in the field of water policy 2008/105/EC, the need for sensitive reference methods was highlighted. Since tributyltin (TBT) is one of the WFD listed priority substances a method was developed which is capable to qualify and quantify the pollutant at the required low WFD EQS of 0.2ngL(-1) in whole water bodies, i.e. in non-filtered water samples with dissolved organic carbon and suspended particulate matter. Therefore special attention was paid on the interaction of TBT with the suspended particulate matter and humic substances to obtain a complete representation of the pollution in surface waters. Different water samples were investigated varying the content of organic dissolved and suspended matter. Quantification was performed using species-specific isotope dilution (SSID) and gas chromatography with inductively coupled plasma mass spectrometry (GC-ICP-MS). Different sample treatment strategies were evaluated and compared. The process of internal standard addition was investigated and optimized, hence the equilibrium between internal standards and matrix is of primary importance to perform accurate SSID. Samples spiked at EQS level were analyzed with a recovery between 95 and 105 %. Additionally real surface water samples were investigated and the TBT concentration for the whole water body was determined and compared with conventional routine analysis method. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Methods for determination of inorganic substances in water and fluvial sediments

    USGS Publications Warehouse

    Fishman, Marvin J.; Friedman, Linda C.

    1989-01-01

    Chapter Al of the laboratory manual contains methods used by the U.S. Geological Survey to analyze samples of water, suspended sediments, and bottom material for their content of inorganic constituents. Included are methods for determining the concentration of dissolved constituents in water, the total recoverable and total of constituents in water-suspended sediment samples, and the recoverable and total concentrations of constituents in samples of bottom material. The introduction to the manual includes essential definitions and a brief discussion of the use of significant figures in calculating and reporting analytical results. Quality control in the water-analysis laboratory is discussed, including the accuracy and precision of analyses, the use of standard-reference water samples, and the operation of an effective quality-assurance program. Methods for sample preparation and pretreatment are given also. A brief discussion of the principles of the analytical techniques involved and their particular application to water and sediment analysis is presented. The analytical methods of these techniques are arranged alphabetically by constituent. For each method, the general topics covered are the application, the principle of the method, the interferences, the apparatus and reagents required, a detailed description of the analytical procedure, reporting results, units and significant figures, and analytical precision data, when available. More than 126 methods are given for the determination of 70 inorganic constituents and physical properties of water, suspended sediment, and bottom material.

  19. Methods for determination of inorganic substances in water and fluvial sediments

    USGS Publications Warehouse

    Fishman, Marvin J.; Friedman, Linda C.

    1985-01-01

    Chapter Al of the laboratory manual contains methods used by the Geological Survey to analyze samples of water, suspended sediments, and bottom material for their content of inorganic constituents. Included are methods for determining the concentration of dissolved constituents in water, total recoverable and total of constituents in water-suspended sediment samples, and recoverable and total concentrations of constituents in samples of bottom material. Essential definitions are included in the introduction to the manual, along with a brief discussion of the use of significant figures in calculating and reporting analytical results. Quality control in the water-analysis laboratory is discussed, including accuracy and precision of analyses, the use of standard reference water samples, and the operation of an effective quality assurance program. Methods for sample preparation and pretreatment are given also.A brief discussion of the principles of the analytical techniques involved and their particular application to water and sediment analysis is presented. The analytical methods involving these techniques are arranged alphabetically according to constituent. For each method given, the general topics covered are application, principle of the method, interferences, apparatus and reagents required, a detailed description of the analytical procedure, reporting results, units and significant figures, and analytical precision data, when available. More than 125 methods are given for the determination of 70 different inorganic constituents and physical properties of water, suspended sediment, and bottom material.

  20. Disinfection of contaminated water by using solar irradiation.

    PubMed

    Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad

    2004-02-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.

  1. Groundwater Quality Data for the Tahoe-Martis Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Fram, Miranda S.; Munday, Cathy; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 460-square-mile Tahoe-Martis study unit was investigated in June through September 2007 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within the Tahoe-Martis study unit (Tahoe-Martis) and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 52 wells in El Dorado, Placer, and Nevada Counties. Forty-one of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 11 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14, strontium isotope ratio, and stable isotopes of hydrogen and oxygen of water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 240 constituents and water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at 12 percent of the wells, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate of compliance or noncompliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from the Tahoe-Martis wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides) were detected in about 40 percent of the samples from grid wells, and most concentrations were less than 1/100th of regulatory and nonregulatory health-based thresholds, although the conentration of perchloroethene in one sample was above the USEPA maximum contaminant level (MCL-US). Concentrations of all trace elements and nutrients in samples from grid wells were below regulatory and nonregulatory health-based thresholds, with five exceptions. Concentra

  2. Algal Data from Selected Sites in the Upper Colorado River Basin, Colorado, Water Years 1996-97

    USGS Publications Warehouse

    Mize, Scott V.; Deacon, Jeffrey R.

    2001-01-01

    Algal community samples were collected at 15 sites in the Upper Colorado River Basin in Colorado as part of the National Water-Quality Assessment Program during water years 1996-97. Sites sampled were located in two physiographic provinces, the Southern Rocky Mountains and the Colorado Plateaus, and represented agricultural, mining, urban, and mixed land uses and background conditions. Algal samples were collected once per year during low-flow conditions. Quantitative algal samples were collected within two targeted instream habitat types including a taxonomically richest-targeted habitat and a depositional-targeted habitat. This report presents the algal community data collected at the fixed sites in the Upper Colorado River Basin study unit. Algal data include densities (abundance of cells per square centimeter of substrate) and biovolumes (cubic micrometers of cells per square centimeter of substrate) for the two habitat types. Quality-assurance and quality-control results for algal samples indicate that the largest sampling variability tends to occur in samples from small streams.

  3. Nitrogen Removal from Micro-Polluted Reservoir Water by Indigenous Aerobic Denitrifiers

    PubMed Central

    Huang, Ting-Lin; Zhou, Shi-Lei; Zhang, Hai-Han; Zhou, Na; Guo, Lin; Di, Shi-Yu; Zhou, Zi-Zhen

    2015-01-01

    Treatment of micro-polluted source water is receiving increasing attention because of environmental awareness on a global level. We isolated and identified aerobic denitrifying bacteria Zoogloea sp. N299, Acinetobacter sp. G107, and Acinetobacter sp. 81Y and used these to remediate samples of their native source water. We first domesticated the isolated strains in the source water, and the 48-h nitrate removal rates of strains N299, G107, and 81Y reached 33.69%, 28.28%, and 22.86%, respectively, with no nitrite accumulation. We then conducted a source-water remediation experiment and cultured the domesticated strains (each at a dry cell weight concentration of 0.4 ppm) together in a sample of source water at 20–26 °C and a dissolved oxygen concentration of 3–7 mg/L for 60 days. The nitrate concentration of the system decreased from 1.57 ± 0.02 to 0.42 ± 0.01 mg/L and that of a control system decreased from 1.63 ± 0.02 to 1.30 ± 0.01 mg/L, each with no nitrite accumulation. Total nitrogen of the bacterial system changed from 2.31 ± 0.12 to 1.09 ± 0.01 mg/L, while that of the control system changed from 2.51 ± 0.13 to 1.72 ± 0.06 mg/L. The densities of aerobic denitrification bacteria in the experimental and control systems ranged from 2.8 × 104 to 2 × 107 cfu/mL and from 7.75 × 103 to 5.5 × 105 cfu/mL, respectively. The permanganate index in the experimental and control systems decreased from 5.94 ± 0.12 to 3.10 ± 0.08 mg/L and from 6.02 ± 0.13 to 3.61 ± 0.11 mg/L, respectively, over the course of the experiment. Next, we supplemented samples of the experimental and control systems with additional bacteria or additional source water and cultivated the systems for another 35 days. The additional bacteria did little to improve the water quality. The additional source water provided supplemental carbon and brought the nitrate removal rate in the experimental system to 16.97%, while that in the control system reached only 3.01%, with no nitrite accumulation in either system. Our results show that aerobic denitrifying bacteria remain highly active after domestication and demonstrate the applicability of such organisms in the bioremediation of oligotrophic ecosystems. PMID:25867475

  4. Quality of water and bottom material in Breckenridge Reservoir, Virginia, September 2008 through August 2009

    USGS Publications Warehouse

    Lotspeich, Russell

    2012-01-01

    Breckenridge Reservoir is located within the U.S. Marine Corps Base in Quantico, which is in the Potomac River basin and the Piedmont Physiographic Province of northern Virginia. Because it serves as the principal water supply for the U.S. Marine Corps Base in Quantico, an assessment of the water-quality of Breckenridge Reservoir was initiated. Water samples were collected and physical properties were measured by the U.S. Geological Survey at three sites in Breckenridge Reservoir, and physical properties were measured at six additional reservoir sites from September 2008 through August 2009. Water samples were also collected and physical properties were measured in each of the three major tributaries to Breckenridge Reservoir: North Branch Chopawamsic Creek, Middle Branch Chopawamsic Creek, and South Branch Chopawamsic Creek. One site on each tributary was sampled at least five times during the study. Monthly profiles were conducted for water temperature, dissolved-oxygen concentrations, specific conductance, pH, and turbidity measured at 2-foot intervals throughout the water column of the reservoir. These profiles were conducted at nine sites in the reservoir, and data values were measured at these sites from the water surface to the bottom of the reservoir. These profiles were conducted along three cross sections and were used to define the characteristics of the entire water column of the reservoir. The analytical results of reservoir and tributary samples collected and physical properties measured during this study were compared to ambient water-quality standards of the Virginia Department of Environmental Quality and Virginia State Water Control Board. Water temperature, dissolved-oxygen concentration, specific conductance, pH, and turbidity measured in Breckenridge Reservoir generally indicated a lack of stratification in the water column of the reservoir throughout the study period. This is unlike most other reservoirs in the region and may be influenced by the reservoir's relatively short length and the aerators that operate in the reservoir near the spillway. In general, the water-quality of Breckenridge Reservoir is similar to other reservoirs in the region, and the measurements made during this study indicate that the reservoir is healthy and is not in violation of published State Water Control Board ambient water-quality standards. Water samples at three reservoir sites were analyzed for 53 pesticides, but only atrazine was found to be above the laboratory minimum reporting level. Atrazine concentrations of 0.008 and 0.010 microgram per liter near the surface and bottom of the reservoir, respectively, were found at all three sampling locations. Bottom-material samples were collected for analysis of trace elements at all three reservoir sampling sites. Concentrations of arsenic, cadmium, and mercury in bottom material were similar to those analyzed in other reservoirs in the region. However, most other constituents that were collected from Breckenridge Reservoir, especially iron and lead, showed much higher concentrations than the other reservoirs. During the course of the study, increased turbidity and Escherichia coli bacteria counts were observed during or after periods of increased tributary discharge, and Secchi-disk depths decreased during those same periods. These streamflow and water-quality indicators suggest a close relationship between Breckenridge Reservoir and its tributaries.

  5. A dryer for rapid response on-line expired gas measurements.

    PubMed

    Deno, N S; Kamon, E

    1979-06-01

    A dryer is described for use in on-line breath-by-breath gas analysis systems. The dryer continuously removes water vapor by condensation and controls the sample gas at 2 degrees C dew-point temperature or 5 Torr water vapor partial pressure. It is designed to operate at gas sampling flow rates from 0.5 to 1 1.min-1. The step-response time for the described system including a Beckman LB-2 CO2 analyzer, sampling tubing, and dryer is 120 ms at 1 l.min-1. The time required for gas samples to transport through the dryer is 105 ms at a gas sampling-flow rate of 1 l.min=1.

  6. Prevalence study of Legionella spp. contamination in ferries and cruise ships

    PubMed Central

    Azara, Antonio; Piana, Andrea; Sotgiu, Giovanni; Dettori, Marco; Deriu, Maria Grazia; Masia, Maria Dolores; Are, Bianca Maria; Muresu, Elena

    2006-01-01

    Background In the last years, international traffic volume has significantly increased, raising the risk for acquisition of infectious diseases. Among travel-associated infections, increased incidence of legionellosis has been reported among travellers. Aim of our study was: to describe the frequency and severity of Legionella spp. contamination in ferries and cruise ships; to compare the levels of contamination with those indicated by the Italian ministerial guidelines for control and prevention of legionellosis, in order to assess health risks and to adopt control measures. Method A prevalence study was carried out on 9 ships docked at the seaports of northern Sardinia in 2004. Water samples were collected from critical sites: passenger cabins, crew cabins, kitchens, coffee bars, rooms of the central air conditioning system. It was performed a qualitative and quantitative identification of Legionella spp. and a chemical, physical and bacteriological analysis of water samples. Results Forty-two percent (38/90) water samples were contaminated by Legionella spp.. Positive samples were mainly drawn from showers (24/44), washbasins (10/22). L. pneumophila was isolated in 42/44 samples (95.5%), followed by L. micdadei (4.5%). Strains were identified as L. pneumophila serogroup 6 (45.2%; 19 samples), 2–14 (42.9%), 5 (7.1%) and 3 (4.8%). Legionella spp. load was high; 77.8% of the water samples contained > 104 CFU/L. Low residual free chlorine concentration (0–0,2 mg/L) was associated to a contamination of the 50% of the water samples. Conclusion Legionella is an ubiquitous bacterium that could create problems for public health. We identified Legionella spp. in 6/7 ferries. Microbial load was predominantly high (> 104 CFU/L or ranging from 103 to 104 CFU/L). It is matter of concern when passengers are subjects at risk because of Legionella spp. is an opportunist that can survive in freshwater systems; high bacterial load might be an important variable related to disease's occurrence. High level of contamination required disinfecting measures, but does not lead to a definitive solution to the problem. Therefore, it is important to identify a person responsible for health safety in order to control the risk from exposure and to apply preventive measures, according to European and Italian guidelines. PMID:16620388

  7. Prevalence study of Legionella spp. contamination in ferries and cruise ships.

    PubMed

    Azara, Antonio; Piana, Andrea; Sotgiu, Giovanni; Dettori, Marco; Deriu, Maria Grazia; Masia, Maria Dolores; Are, Bianca Maria; Muresu, Elena

    2006-04-18

    In the last years, international traffic volume has significantly increased, raising the risk for acquisition of infectious diseases. Among travel-associated infections, increased incidence of legionellosis has been reported among travellers. Aim of our study was: to describe the frequency and severity of Legionella spp. contamination in ferries and cruise ships; to compare the levels of contamination with those indicated by the Italian ministerial guidelines for control and prevention of legionellosis, in order to assess health risks and to adopt control measures. A prevalence study was carried out on 9 ships docked at the seaports of northern Sardinia in 2004. Water samples were collected from critical sites: passenger cabins, crew cabins, kitchens, coffee bars, rooms of the central air conditioning system. It was performed a qualitative and quantitative identification of Legionella spp. and a chemical, physical and bacteriological analysis of water samples. Forty-two percent (38/90) water samples were contaminated by Legionella spp.. Positive samples were mainly drawn from showers (24/44), washbasins (10/22). L. pneumophila was isolated in 42/44 samples (95.5%), followed by L. micdadei (4.5%). Strains were identified as L. pneumophila serogroup 6 (45.2%; 19 samples), 2-14 (42.9%), 5 (7.1%) and 3 (4.8%). Legionella spp. load was high; 77.8% of the water samples contained > 10(4) CFU/L. Low residual free chlorine concentration (0-0.2 mg/L) was associated to a contamination of the 50% of the water samples. Legionella is an ubiquitous bacterium that could create problems for public health. We identified Legionella spp. in 6/7 ferries. Microbial load was predominantly high (> 10(4) CFU/L or ranging from 10(3) to 10(4) CFU/L). It is matter of concern when passengers are subjects at risk because of Legionella spp. is an opportunist that can survive in freshwater systems; high bacterial load might be an important variable related to disease's occurrence. High level of contamination required disinfecting measures, but does not lead to a definitive solution to the problem. Therefore, it is important to identify a person responsible for health safety in order to control the risk from exposure and to apply preventive measures, according to European and Italian guidelines.

  8. The importance of quality control in validating concentrations of contaminants of emerging concern in source and treated drinking water samples

    EPA Science Inventory

    A national scale survey of 251 chemical contaminants in source and finished drinking water was conducted at 25 drinking water treatment plants across the U.S. To address the necessity of using multiple methods in determining a broad array of CECs, we designed a quality assurance/...

  9. Data processing for water monitoring system

    NASA Technical Reports Server (NTRS)

    Monford, L.; Linton, A. T.

    1978-01-01

    Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.

  10. In vitro bioanalysis of drinking water from source to tap.

    PubMed

    Rosenmai, Anna Kjerstine; Lundqvist, Johan; le Godec, Théo; Ohlsson, Åsa; Tröger, Rikard; Hellman, Björn; Oskarsson, Agneta

    2018-08-01

    The presence of chemical pollutants in sources of drinking water is a key environmental problem threatening public health. Efficient removal of pollutants in drinking water treatment plants (DWTPs) is needed as well as methods for assessment of the total impact of all present chemicals on water quality. In the present study we have analyzed the bioactivity of water samples from source to tap, including effects of various water treatments in a DWTP, using a battery of cell-based bioassays, covering health-relevant endpoints. Reporter gene assays were used to analyze receptor activity of the aryl hydrocarbon receptor (AhR), estrogen receptor (ER), androgen receptor (AR), peroxisome proliferator-activated receptor alpha (PPARα) and induction of oxidative stress by the nuclear factor erythroid 2-related factor 2 (Nrf2). DNA damage was determined by Comet assay. Grab water samples were concentrated by HLB or ENV solid phase extraction and the water samples assayed at a relative enrichment factor of 50. The enrichment procedure did not induce any bioactivity. No bioactivity was detected in Milli-Q water or drinking water control samples. Induction of AhR, ER and Nrf2 activities was revealed in source to tap water samples. No cytotoxicity, PPARα or AR antagonist activity, or DNA damage were observed in any of the water samples. A low AR agonist activity was detected in a few samples of surface water, but not in the samples from the DWTP. The treatment steps at the DWTP, coagulation, granulated activated carbon filtration, UV disinfection and NH 2 Cl dosing had little or no effect on the AhR, Nrf2 and ER bioactivity. However, nanofiltration and passage through the distribution network drastically decreased AhR activity, while the effect on Nrf2 activity was more modest and no apparent effect was observed on ER activity. The present results suggest that bioassays are useful tools for evaluation of the efficiency of different treatment steps in DWTPs in reducing toxic activities. Bioassays of AhR and Nrf2 are useful for screening of effects of a broad range of chemicals in drinking water and ER activity can be monitored with a high sensitivity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Arsenic and ultraviolet radiation exposure: melanoma in a New Mexico non-Hispanic white population.

    PubMed

    Yager, Janice W; Erdei, Esther; Myers, Orrin; Siegel, Malcolm; Berwick, Marianne

    2016-06-01

    Cases of cutaneous melanoma and controls were enrolled in a New Mexico population-based study; subjects were administered questionnaires concerning ultraviolet (UV) and inorganic arsenic (iAs) exposure. Historical iAs exposure was estimated. UV exposure estimates were also derived using geospatial methods. Drinking water samples were collected for iAs analysis. Blood samples were collected for DNA repair (Comet) and DNA repair gene polymorphism assays. Arsenic concentrations were determined in urine and toenail samples. UV exposures during the previous 90 days did not vary significantly between cases and controls. Mean (±SD) current home iAs drinking water was not significantly different for cases and controls [3.98 μg/L (±3.67) vs. 3.47 μg/L (±2.40)]. iAs exposure showed no effect on DNA repair or association with melanoma. Results did not corroborate a previously reported association between toenail As and melanoma risk. Arsenic biomarkers in urine and toenail were highly significantly correlated with iAs in drinking water. A UV-DNA repair interaction for UV exposure over the previous 7-90 days was shown; cases had higher DNA damage than controls at low UV values. This novel finding suggests that melanoma cases may be more sensitive to low-level UV exposure than are controls. A UV-APEX1 interaction was shown. Subjects with the homozygous rare APEX1 DNA repair gene allele had a higher risk of early melanoma diagnosis at low UV exposure compared with those with the homozygous wild type or the heterozygote. Notably, a UV-arsenic interaction on inhibition of DNA repair was not observed at iAs drinking water concentrations below 10 ppb (μg/L).

  12. BASIC Programming In Water And Wastewater Analysis

    NASA Technical Reports Server (NTRS)

    Dreschel, Thomas

    1988-01-01

    Collection of computer programs assembled for use in water-analysis laboratories. First program calculates quality-control parameters used in routine water analysis. Second calculates line of best fit for standard concentrations and absorbances entered. Third calculates specific conductance from conductivity measurement and temperature at which measurement taken. Fourth calculates any one of four types of residue measured in water. Fifth, sixth, and seventh calculate results of titrations commonly performed on water samples. Eighth converts measurements, to actual dissolved-oxygen concentration using oxygen-saturation values for fresh and salt water. Ninth and tenth perform calculations of two other common titrimetric analyses. Eleventh calculates oil and grease residue from water sample. Last two use spectro-photometric measurements of absorbance at different wavelengths and residue measurements. Programs included in collection written for Hewlett-Packard 2647F in H-P BASIC.

  13. Groundwater microbiological quality in Canadian drinking water municipal wells.

    PubMed

    Locas, Annie; Barthe, Christine; Margolin, Aaron B; Payment, Pierre

    2008-06-01

    To verify previous conclusions on the use of bacterial indicators suggested in regulations and to investigate virological quality of groundwater, a 1-year study was undertaken on groundwater used as a source of drinking water in 3 provinces in Canada. Raw water from 25 municipal wells was sampled during a 1-year period for a total of 167 samples. Twenty-three sites were selected on the basis of their excellent historical bacteriological water quality data, and 2 sites with known bacteriological contamination were selected as positive controls. Water samples were analyzed for general water quality indicators (aerobic endospores, total coliforms), fecal indicators (Escherichia coli, enterococci, somatic and male-specific coliphages), total culturable human enteric viruses (determined by cell culture and immunoperoxidase), noroviruses (analyzed by reverse-transcriptase -- polymerase chain reaction (RT-PCR)), adenovirus types 40 and 41 (analyzed by integrated cell culture (ICC) - PCR), and enteroviruses and reoviruses types 1, 2, and 3 (analyzed by ICC-RT-PCR). General water quality indicators were found very occasionally at the clean sites but were frequently present at the 2 contaminated sites. Only one of 129 samples from the 23 clean sites was positive for enterococci. These results confirm the value of raw water quality historical data to detect source water contamination affecting wells that are vulnerable. Samples from the 2 contaminated sites confirmed the frequent presence of fecal indicators: E. coli was found in 20/38 samples and enterococci in 12/38 samples. Human enteric viruses were not detected by cell culture on MA-104 cells nor by immunoperoxidase detection in any sample from the clean sites but were found at one contaminated site. By ICC-RT-PCR and ICC-PCR, viruses were found by cytopathic effect in one sample from a clean site and they were found in 3 samples from contaminated sites. The viruses were not detected by the molecular methods but were confirmed as picornaviruses by electron microscopy. Noroviruses were not detected in any samples. The results obtained reinforce the value of frequent sampling of raw water using simple parameters: sampling for total coliforms and E. coli remains the best approach to detect contamination of source water by fecal pollutants and accompanying pathogens. The absence of total coliforms at a site appears to be a good indication of the absence of human enteric viruses.

  14. [Value of specific 16S rDNA fragment of algae in diagnosis of drowning: an experiment with rabbits].

    PubMed

    Li, Peng; Xu, Qu-Yi; Chen, Ling; Liu, Chao; Zhao, Jian; Wang, Yu-Zhong; Yu, Zheng-Liang; Hu, Sun-Lin; Wang, Hui-Jun

    2015-08-01

    To establish a method for amplifying specific 16S rDNA fragment of algae related with drowning and test its value in drowning diagnosis. Thirty-five rabbits were randomly divided into 3 the drowning group (n=15), postmortem water immersion group (n=15, subjected to air embolism before seawater immersion), and control group(n=5, with air embolism only). Twenty samples of the liver tissues from human corpses found in water were also used, including 14 diatom-positive and 6 diatom-negative samples identified by microwave digestion-vacuum filtration-automated scanning electron microscopy (MD-VF-Auto SEM). Seven known species of algae served as the control algae (Melosira sp, Nitzschia sp, Synedra sp, Navicula sp, Microcystis sp, Cyclotella meneghiniana, and Chlorella sp). The total DNA was extracted from the tissues and algae to amplify the specific fragment of algae followed by 8% polyacrylamide gelelectrophoresis and sliver-staining. In the drowning group, algae was detected in the lungs (100%), liver (86%), and kidney (86%); algae was detected in the lungs in 2 rabbits in the postmortem group (13%) and none in the control group. The positivity rates of algae were significantly higher in the drowning group than in the postmortem group (P<0.05). Of the 20 tissue samples from human corps found in water, 15 were found positive for algae, including sample that had been identified as diatom-negative by MD-VF-Auto SEM. All the 7 control algae samples yielded positive results in PCR. The PCR-based method has a high sensitivity in algae detection for drowning diagnosis and allows simultaneous detection of multiple algae species related with drowning.

  15. Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines

    PubMed Central

    Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan

    2014-01-01

    Background: It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. Materials and Methods: In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann — Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. Results: All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. Conclusion: The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines. PMID:25097645

  16. Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines.

    PubMed

    Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan

    2014-05-01

    It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann - Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines.

  17. Groundwater Quality Data for the Northern Sacramento Valley, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Bennett, Peter A.; Bennett, George L.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 1,180-square-mile Northern Sacramento Valley study unit (REDSAC) was investigated in October 2007 through January 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within REDSAC and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 66 wells in Shasta and Tehama Counties. Forty-three of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 23 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial constituents. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of nitrogen and oxygen in nitrate, stable isotopes of hydrogen and oxygen of water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 275 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and sampmatrix spikes) were collected at approximately 8 to 11 percent of the wells, and the results for these samples were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges for nearly all compounds, indicating acceptably low variability. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples from REDSAC were below drinking-water thresholds. Volatile organic compounds (VOC) and pesticides were detected in less than one-quarter of the samples and were generally less than a hundredth of any health-based thresholds. NDMA was detected in one grid well above the NL-CA. Concentrations of all nutrients and trace elements in samples from REDSAC wells were below the health-based thresholds except those of arsenic in three samples, which were above the USEPA maximum contaminant level (MCL-US). However

  18. Groundwater environmental tracer data collected from the Chicot, Evangeline, and Jasper aquifers in Montgomery County and adjacent counties, Texas, 2008

    USGS Publications Warehouse

    Oden, Timothy D.

    2011-01-01

    The Gulf Coast aquifer system is the primary water supply for Montgomery County in southeastern Texas, including part of the Houston metropolitan area and the cities of Magnolia, Conroe, and The Woodlands Township, Texas. The U.S. Geological Survey, in cooperation with the Lone Star Groundwater Conservation District, collected environmental tracer data in the Gulf Coast aquifer system, primarily in Montgomery County. Forty existing groundwater wells screened in the Gulf Coast aquifer system were selected for sampling in Montgomery County (38 wells), Waller County (1 well), and Walker County (1 well). Groundwater-quality samples, physicochemical properties, and water-level data were collected once from each of the 40 wells during March-September 2008. Groundwater-quality samples were analyzed for dissolved gases and the environmental tracers sulfur hexafluoride, chlorofluorocarbons, tritium, helium-4, and helium-3/tritium. Water samples were collected and processed onsite using methods designed to minimize changes to the water-sample chemistry or contamination from the atmosphere. Replicate samples for quality assurance and quality control were collected with each environmental sample. Well-construction information and environmental tracer data for March-September 2008 are presented.

  19. Developmental toxicity of treated municipal wastewater effluent on Bombina orientalis (Amphibia: Anura) embryos.

    PubMed

    Park, Chan Jin; Ahn, Hyo Min; Cho, Seong Chan; Kim, Tae-Hoon; Oh, Jong-Min; Ahn, Hong Kyu; Chun, Seung-Hoon; Gye, Myung Chan

    2014-04-01

    Amphibian populations have been decreasing in urban freshwater systems in Korea. To elucidate the biological safety of treated wastewater effluent (TWE) in the Tancheon basin, the capital area of Korea, a 7-d-exposure Bombina orientalis embryo developmental toxicity assay was examined during the breeding season. In March, there were no significant differences in embryonic survival or malformation among the water samples. In July, following monsoon precipitation, embryonic lethality in TWE was significantly higher than in the upstream water sample. Malformation in TWE and TWE-mixed waters was significantly higher than in the control and upstream water samples. Tail muscle height of tadpoles also significantly decreased in TWE and TWE-mixed waters. Heavy metals were not detected in any samples. Total nitrogen, total phosphorous, and chemical oxygen demand in TWE markedly increased together with a decrease in dissolved oxygen in July. The increase in organic and inorganic loading following precipitation could have made TWE and TWE-mixed water not suitable for embryonic development. Though being managed based on physicochemical criteria, the water quality of TWE may not be sufficient to assure normal development of amphibian embryos. An amphibian developmental toxicity assay would be helpful for the water-quality management of TWE and urban freshwater systems in Korea. © 2014 SETAC.

  20. Randomized controlled trial in rural Ethiopia to assess a portable water treatment device.

    PubMed

    Boisson, Sophie; Schmidt, Wolf-Peter; Berhanu, Tsegahiwot; Gezahegn, Henock; Clasen, Thomas

    2009-08-01

    We conducted a randomized controlled trial to assess the Lifestraw Personal pipe-style water treatment device among a rural population in Ethiopia. A total of 313 households (including 1516 persons) were randomly assigned either to an intervention group in which each householder received a Lifestraw Personal or a control. Households were visited fortnightly over a five-month intervention period and asked to report any episode of diarrhea during the previous week. A random sample of 160 devices was tested each month to assess the presence of thermotolerant coliforms (TTC) and residual iodine in treated water and to measure flow rate under simulated use. Members of the intervention group had 25% fewer weeks with diarrhea than those of the control group (longitudinal prevalence ratio = 0.75; 95% CI 0.60; 0.95). All 718 filtered water samples were free of TTC, were free of detectable iodine disinfectant, and showed a constant flow rate over time. After the five-month intervention period, 34% of participants reported use of device in the preceding week and 13% reported consistent use. While the device was associated with a 25% reduction in longitudinal prevalence of diarrhea, low levels of use suggest that much of this effect is likely to be attributable to reporting bias that is common in open trials with nonobjective outcomes.

  1. The effect of Cinnamomum zeylanicum essential oil on chemical characteristics of Lyoner- type sausage during refrigerated storage

    PubMed Central

    Aminzare, Majid; Aliakbarlu, Javad; Tajik, Hossein

    2015-01-01

    The effect of Cinnamomum zeylanicum essential oil (CZEO) at two concentrations (0.02% and 0.04% v/w) on chemical composition, pH, water activity (aw), lipid oxidation, color stability and sensory characteristics of Lyoner-type sausage stored at 4 ˚C for 40 days was investigated. The moisture content of the control sample was higher (p < 0.05) than CZEO incorporated samples, while fat, ash and protein content were not affected by adding essential oil. At days 0 and 40, Lightness (L*) and whiteness index (WI) were significantly decreased and total color difference (ΔE) significantly increased (p < 0.05) by adding CZEO. With the exception of first day of storage, redness (a*) and yellowness (b*) were significantly increased and decreased, respectively during the rest of storage (p < 0.05). The pH values were not differing between the control samples and samples containing CZEO (p > 0.05). The water activity content fell in Lyoners with added CZEO during the storage. Incorporation of CZEO retard lipid oxidation process at the end of storage (p < 0.05). Samples containing highest amount of CZEO had higher sensory score compared to control sample. Our results pointed out that CZEO could be used as natural additive for increasing the chemical stability of Lyoner-type sausages. PMID:25992249

  2. Isotope fractionation of sandy-soil water during evaporation - an experimental study.

    PubMed

    Rao, Wen-Bo; Han, Liang-Feng; Tan, Hong-Bing; Wang, Shuai

    2017-06-01

    Soil samples containing water with known stable isotopic compositions were prepared. The soil water was recovered by using vacuum/heat distillation. The experiments were held under different conditions to control rates of water evaporation and water recovery. Recoveries, δ 18 O and δ 2 H values of the soil water were determined. Analyses of the data using a Rayleigh distillation model indicate that under the experimental conditions only loosely bound water is extractable in cases where the recovery is smaller than 100 %. Due to isotopic exchange between vapour and remaining water in the micro channels or capillaries of the soil matrix, isotopic fractionation may take place under near-equilibrium conditions. This causes the observed relationship between δ 2 H and δ 18 O of the extracted water samples to have a slope close to 8. The results of this study may indicate that, in arid zones when soil that initially contains water dries out, the slope of the relationship between δ 2 H and δ 18 O values should be close to 8. Thus, a smaller slope, as observed by some groundwater and soil water samples in arid zones, may be caused by evaporation of water before the water has entered the unsaturated zone.

  3. The response of water quality variation in Poyang Lake (Jiangxi, People's Republic of China) to hydrological changes using historical data and DOM fluorescence.

    PubMed

    Yao, Xin; Wang, Shengrui; Ni, Zhaokui; Jiao, Lixin

    2015-02-01

    Poyang Lake is a unique wetland system that has evolved in response to natural seasonal fluctuations in water levels. To better characterize the response of water quality to hydrological variation, historical data were analyzed in combination with dissolved organic matter (DOM) fluorescence samplings conducted in situ. Historical data showed that long-term changes in water quality are mainly controlled by the sewage inputs to Poyang Lake. Monthly changes in water quality recorded during 2008 and 2012 suggest that water level may be the most important factor for water quality during a hydrological year. DOM fluorescence samples were identified as three humic-like components (C1, C2, and C3) and a protein-like component (C4). These obvious compositional changes in DOM fluorescence were considered to be related to the hydrodynamic differences controlled by water regimen. Principal component analysis (PCA) showed higher C1 and C2 signals during a normal season than the wet season, whereas C3 was lower, and C4 was higher in the dry season than in the wet or normal seasons. From the open lake to the Yangtze River mouth, increased C3 component carried by backflows of the Yangtze River to the lake resulted in these unique variations of PCA factor 2 scores during September. These obvious compositional changes in DOM fluorescence were considered to be related to the hydrodynamic differences controlled by water regimen. DOM fluorescence could be a proxy for capturing rapid changes in water quality and thereby provide an early warning signal for the quality of water supply.

  4. Effect of ammonium hydroxide on ultrastructure and tenderness of buffalo meat.

    PubMed

    Naveena, B M; Kiran, M; Reddy, K Sudhakar; Ramakrishna, C; Vaithiyanathan, S; Devatkal, Suresh K

    2011-08-01

    This study was conducted with an objective to improve the tenderness of tough buffalo meat using ammonium hydroxide. Buffalo meat chunks from Biceps femoris muscle were marinated with distilled water (control), 0.1%, 0.5% and 1.0% solution of ammonium hydroxide for 48 h at 4±1 °C and subjected to various physico-chemical analysis and ultrastructural studies. Ammonium hydroxide increased (P<0.05) the pH, water holding capacity (WHC), collagen solubility, total and salt soluble protein extractability and cooking yield. Reduction (P<0.05) in Warner-Bratzler shear force values were observed in all ammonium hydroxide treated samples compared to non-treated control. Electrophoretic pattern of muscle proteins exhibited reduction in the intensity and number of certain protein bands for 0.1% and 0.5% ammonium hydroxide treated samples compared to control. Scanning and transmission electron microscopy also revealed breakdown of endothelium layers surrounding muscle fibers and weakening of Z-discs respectively, in treated samples compared to controls. These results suggest that ammonium hydroxide might be used to tenderize tough buffalo meat. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Developing a Systematic Corrosion Control Evaluation Approach in Flint

    EPA Science Inventory

    Presentation covers what the projects were that were recommended by the Flint Safe Drinking Water Task Force for corrosion control assessment for Flint, focusing on the sequential sampling project, the pipe rigs, and pipe scale analyses.

  6. WATER FROM DIFFERENT SOURCES USED FOR THE IRRIGATION OF VEGETABLES TO BE MARKETED: RESEARCH ON Cryptosporidium spp., Giardia spp., AND COLIFORMS IN PARANA, BRAZIL.

    PubMed

    Tiyo, Rogerio; de Souza, Carla Zangari; Nishi, Letícia; Brustolin, Camila Fernanda; Ratti, Bianca Altrão; Falavigna Guilherme, Ana Lucia

    2015-01-01

    The aim of this work was to compare, from a parasitological ( Cryptosporidium spp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidium spp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardia spp. or Cryptosporidium spp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidium spp. and Giardia spp., as well as artesian wells for coliform control in local production of vegetables to be marketed.

  7. WATER FROM DIFFERENT SOURCES USED FOR THE IRRIGATION OF VEGETABLES TO BE MARKETED: RESEARCH ON Cryptosporidium spp., Giardia spp., AND COLIFORMS IN PARANA, BRAZIL

    PubMed Central

    TIYO, Rogerio; de SOUZA, Carla Zangari; NISHI, Letícia; BRUSTOLIN, Camila Fernanda; RATTI, Bianca Altrão; FALAVIGNA GUILHERME, Ana Lucia

    2015-01-01

    SUMMARY The aim of this work was to compare, from a parasitological ( Cryptosporidiumspp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidiumspp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardiaspp. or Cryptosporidiumspp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidiumspp. and Giardiaspp., as well as artesian wells for coliform control in local production of vegetables to be marketed. PMID:26422158

  8. Polycyclic Aromatic Hydrocarbons Concentrations in Drinking Water in Villages along the Huai River in China and Their Association with High Cancer Incidence in Local Population.

    PubMed

    Pan, En Chun; Sun, Hong; Xu, Qiu Jin; Zhang, Qin; Liu, Lin Fei; Chen, Xiao Dong; Xu, Yan

    2015-01-01

    This study aims to evaluate the carcinogenic risk of PAHs in the drinking water of counties along the Huai River in China and study their associations with high cancer incidence in local population. We investigated 20 villages with high cancer incidence rates as the risk group and 20 villages with low rates as the control group. Water samples from each village were collected in the winter and summer seasons to analyze the concentrations of 16 PAHs. The carcinogenic risks of the PAHs were calculated for each village using a health risk assessment approach. Results showed that PAHs concentrations in 27.2% of the water samples were higher than the allowable values in China. However, no significant difference in water PAHs concentrations was observed between the risk and control groups (P > 0.05), and no correlation was found between water PAHs concentrations and cancer incidence in these villages. The average upper bound carcinogenic risks were less than 1 × 10(-4) in both groups. In conclusion, PAHs were present in the drinking water of the studied villages, but their carcinogenic risks remained within acceptable limits. PAHs in local drinking water might not be the major environmental cause of the high cancer incidences.

  9. Polycyclic Aromatic Hydrocarbons Concentrations in Drinking Water in Villages along the Huai River in China and Their Association with High Cancer Incidence in Local Population

    PubMed Central

    Pan, En chun; Sun, Hong; Xu, Qiu jin; Zhang, Qin; Liu, Lin fei; Chen, Xiao dong; Xu, Yan

    2015-01-01

    This study aims to evaluate the carcinogenic risk of PAHs in the drinking water of counties along the Huai River in China and study their associations with high cancer incidence in local population. We investigated 20 villages with high cancer incidence rates as the risk group and 20 villages with low rates as the control group. Water samples from each village were collected in the winter and summer seasons to analyze the concentrations of 16 PAHs. The carcinogenic risks of the PAHs were calculated for each village using a health risk assessment approach. Results showed that PAHs concentrations in 27.2% of the water samples were higher than the allowable values in China. However, no significant difference in water PAHs concentrations was observed between the risk and control groups (P > 0.05), and no correlation was found between water PAHs concentrations and cancer incidence in these villages. The average upper bound carcinogenic risks were less than 1 × 10−4 in both groups. In conclusion, PAHs were present in the drinking water of the studied villages, but their carcinogenic risks remained within acceptable limits. PAHs in local drinking water might not be the major environmental cause of the high cancer incidences. PMID:26688818

  10. Can water-level management reduce malaria mosquito abundance around large dams in sub-Saharan Africa?

    PubMed Central

    Wilson, G. Glenn; Ryder, Darren; Tekie, Habte; Petros, Beyene

    2018-01-01

    Background Water level management has been suggested as a potential tool to reduce malaria around large reservoirs. However, no field-based test has been conducted to assess the effect of water level management on mosquito larval abundance in African settings. The objective of the present study is to evaluate the effects of water level drawdown rates on mosquito larval abundance. Methods Twelve experimental dams were constructed on the foreshore of the Koka Dam in Ethiopia. These were grouped into four daily water drawdown treatments, each with three replicates: no water-level drawdown (Group 1; Control), 10 mm.d-1 (Group 2), 15 mm.d-1 (Group 3) and 20 mm.d-1 (Group 4). Larval sampling was conducted weekly for a period of 6 weeks each in the main malaria transmission season (October to November 2013) and subsequent dry season (February to March 2014). Larval densities were compared among treatments over time using repeated measures Analysis of Variance (ANOVA). Results A total of 284 Anopheles mosquito larvae were collected from the experimental dams during the study period. Most (63.4%; n = 180) were collected during the main malaria transmission season while the remaining (36.6%; n = 104) were collected during the dry season. Larvae comprised four Anopheles species, dominated by Anopheles arabiensis (48.1% of total larval samples; n = 136) and An. pharoensis (33.2%; n = 94). Mean larval density was highest in control treatment dams with stable water levels throughout the study, and decreased significantly (P < 0.05) with increasing water drawdown rates in both seasons. During the main transmission season, anopheline larval density was generally lower by 30%, 70% and 84% in Groups 2, Group 3 and Group 4, respectively, compared with the control dams (Group 1). In the dry season, larval density was reduced by 45%, 70% and 84% in Groups 2, Group 3 and Group 4, respectively, when compared to the control dams. Conclusion Increased water drawdown rates were associated with lower mosquito larval abundance. Water level management could thus serve as a potential control measure for malaria vectors around reservoirs by regulating the persistence of shallow shoreline breeding habitats. Dam operators and water resource managers should consider incorporating water level management as a malaria control mechanism into routine dam operations to manage the risk of malaria transmission to human populations around reservoirs. PMID:29672560

  11. Evaluation of pulsed light treatments on inactivation of Salmonella on blueberries and its impact on shelf-life and quality attributes.

    PubMed

    Cao, Xinang; Huang, Runze; Chen, Haiqiang

    2017-11-02

    Blueberry have a short shelf life when fully ripe and susceptible to contamination of various pathogens. Our study investigated the effect of pulsed light (PL) on inactivation of Salmonella on blueberries and its impact on shelf-life, quality attributes and health-benefit compounds of blueberries. Dry PL (6J/cm 2 ) and water-assisted PL (samples were agitated in water during PL treatment; 9J/cm 2 ) along with two controls, dry control (untreated) and water-assisted control (water washing without PL), were applied to blueberries with subsequent storages at room temperature (3days) or 5°C (7days). For Salmonella inactivation, dry PL treatment achieved 0.9 and 0.6 log reduction of Salmonella for spot and dip inoculation, respectively; while the water-assisted PL treatment reduced Salmonella by 4.4 log and 0.8 log for spot and dip inoculation, respectively. The water-assisted PL treatment resulted in Salmonella populations significantly lower than the dry control after storage regardless of the storage temperature and inoculation method. Neither dry nor water-assisted PL treatments improved the shelf life of blueberries even though direct inactivation of natural yeasts and molds were achieved. Surface lightness was instantly reduced after both dry and water-assisted PL treatments. Compared with the dry control, the two PL treatments did not reduce the firmness of blueberries. Weight loss was increased for the dry PL treated samples, but not for the water-assisted PL treatment for both storage conditions. Delayed anthocyanins accumulation and reduced total antioxidant activity were induced by both PL treatments at the end of storage at room temperature, while slight enhancement in total phenolics content was achieved by water-assisted PL treatment. In conclusion, the water-assisted PL treatment could effectively decontaminate Salmonella on blueberries while showed minimal or no impact on the shelf-life, quality attributes and health-benefit compounds of blueberries. PL processing parameters need to be further evaluated and optimized before possible application in the blueberry industry. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Determination of fluoride in water - A modified zirconium-alizarin method

    USGS Publications Warehouse

    Lamar, W.L.

    1945-01-01

    A convenient, rapid colorimetric procedure using the zirconium-alizarin indicator acidified with sulfuric acid for the determination of fluoride in water is described. Since this acid indicator is stable indefinitely, it is more useful than other zirconium-alizarin reagents previously reported. The use of sulfuric acid alone in acidifying the zirconium-alizarin reagent makes possible the maximum suppression of the interference of sulfate. Control of the pH of the samples eliminates errors due to the alkalinity of the samples. The fluoride content of waters containing less than 500 parts per million of sulfate and less than 1000 p.p.m. of chloride may be determined within a limit of 0.1 p.p.m. when a 100-ml. sample is used.

  13. DESIGN, DEVELOPMENT, AND FIELD DEMONSTRATION OF A REMOTELY DEPLOYABLE WATER QUALITY MONITORING SYSTEM

    EPA Science Inventory

    A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a...

  14. THE EFFECTS OF SCALE, DISTANCE AND TIME ON DRINKING WATER SYSTEMS RESEARCH

    EPA Science Inventory

    This presentation introduces and describes many components related to what generates and/or controls the concentrations of metals and other constituents in drinking water. Emphasis is placed on ways in which sampling protocol affects apparent levels of constituents, and the magn...

  15. DEVELOPMENT OF HOMOLOGOUS VIRAL INTERNAL CONTROLS FOR USE IN RT-PCR ASSAYS OF WATERBORNE ENTERIC VIRUSES

    EPA Science Inventory

    Enteric viruses often contaminate water sources causing frequent outbreaks of gastroenteritis. Reverse transcription-polymerase chain reaction (RT-PCR) assays are commonly used for detection of human enteric viruses in environmental and drinking water samples. RT-PCR provides ...

  16. HydroCrowd: a citizen science snapshot to assess the spatial control of nitrogen solutes in surface waters

    PubMed Central

    Breuer, Lutz; Hiery, Noreen; Kraft, Philipp; Bach, Martin; Aubert, Alice H.; Frede, Hans-Georg

    2015-01-01

    We organized a crowdsourcing experiment in the form of a snapshot sampling campaign to assess the spatial distribution of nitrogen solutes, namely, nitrate, ammonium and dissolved organic nitrogen (DON), in German surface waters. In particular, we investigated (i) whether crowdsourcing is a reasonable sampling method in hydrology and (ii) what the effects of population density, soil humus content and arable land were on actual nitrogen solute concentrations and surface water quality. The statistical analyses revealed a significant correlation between nitrate and arable land (0.46), as well as soil humus content (0.37) but a weak correlation with population density (0.12). DON correlations were weak but significant with humus content (0.14) and arable land (0.13). The mean contribution of DON to total dissolved nitrogen was 22%. Samples were classified as water quality class II or above, following the European Water Framework Directive for nitrate and ammonium (53% and 82%, respectively). Crowdsourcing turned out to be a useful method to assess the spatial distribution of stream solutes, as considerable amounts of samples were collected with comparatively little effort. PMID:26561200

  17. Quality control for federal clean water act and safe drinking water act regulatory compliance.

    PubMed

    Askew, Ed

    2013-01-01

    QC sample results are required in order to have confidence in the results from analytical tests. Some of the AOAC water methods include specific QC procedures, frequencies, and acceptance criteria. These are considered to be the minimum controls needed to perform the method successfully. Some regulatory programs, such as those in 40 CFR Part 136.7, require additional QC or have alternative acceptance limits. Essential QC measures include method calibration, reagent standardization, assessment of each analyst's capabilities, analysis of blind check samples, determination of the method's sensitivity (method detection level or quantification limit), and daily evaluation of bias, precision, and the presence of laboratory contamination or other analytical interference. The details of these procedures, their performance frequency, and expected ranges of results are set out in this manuscript. The specific regulatory requirements of 40 CFR Part 136.7 for the Clean Water Act, the laboratory certification requirements of 40 CFR Part 141 for the Safe Drinking Water Act, and the ISO 17025 accreditation requirements under The NELAC Institute are listed.

  18. Groundwater-quality data from the National Water-Quality Assessment Project, January through December 2014 and select quality-control data from May 2012 through December 2014

    USGS Publications Warehouse

    Arnold, Terri L.; Bexfield, Laura M.; Musgrove, MaryLynn; Lindsey, Bruce D.; Stackelberg, Paul E.; Barlow, Jeannie R.; Desimone, Leslie A.; Kulongoski, Justin T.; Kingsbury, James A.; Ayotte, Joseph D.; Fleming, Brandon J.; Belitz, Kenneth

    2017-10-05

    Groundwater-quality data were collected from 559 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from January through December 2014. The data were collected from four types of well networks: principal aquifer study networks, which are used to assess the quality of groundwater used for public water supply; land-use study networks, which are used to assess land-use effects on shallow groundwater quality; major aquifer study networks, which are used to assess the quality of groundwater used for domestic supply; and enhanced trends networks, which are used to evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, radionuclides, and some constituents of special interest (arsenic speciation, chromium [VI] and perchlorate). These groundwater-quality data, along with data from quality-control samples, are tabulated in this report and in an associated data release.

  19. Determination of interstitial chloride in shales and consolidated rocks by a precision leaching technique

    USGS Publications Warehouse

    Manheim, Frank T.; Peck, E.E.; Lane, Candice M.

    1985-01-01

    The authors have devised a technique for determining chloride in interstitial water of consolidated rocks. Samples of rocks ranging from 5 to 10 g are crushed and sieved under controlled conditions and then ground with distilled water to submicron size in a closed mechanical mill. The chloride concentrations and total pore-water concentrations, obtained earlier from the same samples by low-temperature vacuum desiccation, are used to arrive at the 'original' pore-water chloride concentrations by a simple iteration procedure. Interstitial chlorinity results obtained from Cretaceous and Jurassic strata in the Gulf of Mexico coastal areas ranged from 20 to 100 g/kg Cl with reproducibility approaching plus or minus 1%.

  20. Influence of Air Humidity and Water Particles on Dust Control Using Ultrasonic Atomization

    NASA Astrophysics Data System (ADS)

    Okawa, Hirokazu; Nishi, Kentaro; Shindo, Dai; Kawamura, Youhei

    2012-07-01

    The influence of air humidity and water particles on dust control was examined using ultrasonic atomization at 2.4 MHz, an acrylic box (61 L), and four types of ore dust samples: green tuff (4 µm), green tuff (6 µm), kaolin, and silica. It was clearly demonstrated that ultrasonic atomization was effective in raising humidity rapidly. However, at high relative air humidity, the water particles remained stable in the box without changing to water vapor. Ultrasonic atomization was applied to suppress dust dispersion and 40-95% dust reduction was achieved at 83% relative air humidity. Dust dispersion was more effective with ultrasonic atomization than without.

  1. The mobilization of aluminum in a natural soil system: Effects of hydrologic pathways

    USGS Publications Warehouse

    Cozzarelli, Isabelle M.; Herman, Janet S.; Parnell, Roderic A.

    1987-01-01

    A two-component soil water flow model was used in conjunction with an equilibrium speciation model WATEQF to study aluminum mobility in soils of a forested watershed, White Oak Run, in the Shenandoah National Park, Virginia. Soil solution samples, taken from the O, E, B, C1, and C2horizons, were collected from zero-tension lysimeters designed to collect faster gravitational macropore flow and tension lysimeters designed to collect slower capillary micropore flow. Dissolved aluminum was fractionated into acid-soluble, inorganic monomeric, and organic monomeric aluminum. Soil water aluminum concentrations decreased with depth indicating that the deep soil is a sink for aluminum. All waters contained significant concentrations of acid-soluble aluminum and exhibited a negative correlation between pH and the inorganic monomeric aluminum concentrations. Water in the shallow soil showed distinctly different chemical compositions for the two flow types, while C horizon micropore and macropore waters were more similar. Because of its shorter residence time, water flowing in deep soil macropores underwent less extensive neutralization and immobilization of aqueous aluminum than micropore water. The O horizon macropore waters were undersaturated for all hydroxide, silicate, and sulfate mineral phases considered. The C horizon samples from both flow types were near equilibrium with respect to kaolinite and synthetic gibbsite, indicating that mineral solubility controls water chemistry in the deep soil, while organic substances are the key control in the shallow macropore waters.

  2. Geochemical processes controlling water salinization in an irrigated basin in Spain: identification of natural and anthropogenic influence.

    PubMed

    Merchán, D; Auqué, L F; Acero, P; Gimeno, M J; Causapé, J

    2015-01-01

    Salinization of water bodies represents a significant risk in water systems. The salinization of waters in a small irrigated hydrological basin is studied herein through an integrated hydrogeochemical study including multivariate statistical analyses and geochemical modeling. The study zone has two well differentiated geologic materials: (i) Quaternary sediments of low salinity and high permeability and (ii) Tertiary sediments of high salinity and very low permeability. In this work, soil samples were collected and leaching experiments conducted on them in the laboratory. In addition, water samples were collected from precipitation, irrigation, groundwater, spring and surface waters. The waters show an increase in salinity from precipitation and irrigation water to ground- and, finally, surface water. The enrichment in salinity is related to the dissolution of soluble mineral present mainly in the Tertiary materials. Cation exchange, precipitation of calcite and, probably, incongruent dissolution of dolomite, have been inferred from the hydrochemical data set. Multivariate statistical analysis provided information about the structure of the data, differentiating the group of surface waters from the groundwaters and the salinization from the nitrate pollution processes. The available information was included in geochemical models in which hypothesis of consistency and thermodynamic feasibility were checked. The assessment of the collected information pointed to a natural control on salinization processes in the Lerma Basin with minimal influence of anthropogenic factors. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. USGS Blind Sample Project: monitoring and evaluating laboratory analytical quality

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.

    1997-01-01

    The U.S. Geological Survey (USGS) collects and disseminates information about the Nation's water resources. Surface- and ground-water samples are collected and sent to USGS laboratories for chemical analyses. The laboratories identify and quantify the constituents in the water samples. Random and systematic errors occur during sample handling, chemical analysis, and data processing. Although all errors cannot be eliminated from measurements, the magnitude of their uncertainty can be estimated and tracked over time. Since 1981, the USGS has operated an independent, external, quality-assurance project called the Blind Sample Project (BSP). The purpose of the BSP is to monitor and evaluate the quality of laboratory analytical results through the use of double-blind quality-control (QC) samples. The information provided by the BSP assists the laboratories in detecting and correcting problems in the analytical procedures. The information also can aid laboratory users in estimating the extent that laboratory errors contribute to the overall errors in their environmental data.

  4. Comparison of the ActiDes-Blue and CARELA HYDRO-DES technology for the sanitation of contaminated cooling water systems in dental units.

    PubMed

    Kramer, Axel; Lemanski, Sandra; Demond, Kathleen; Assadian, Ojan

    2012-01-01

    The hygienic-microbiological control of 6 dental units being in use for the past 16 years revealed a significantly increased microbial contamination of their cooling water system. In order to comply with the requirements of the drinking water directive ("Trinkwasserverordnung"), the commercially available production system ActiDes, producing on-site ActiDes-Blue which is based on hypochlorous acid (HOCl) and generated by anodic oxidation, was investigated. Water samples from the 6 contaminated dental units were examined for the total number of colony forming units (cfu), contamination with molds, L. pneumophila and P. aeruginosa. The control period for the total colony count was 4 weeks (8 samples/unit). The subsequent application phase of the ActiDes-Blue procedure was 6 months (31 samples/unit). Additionally, the redox potential and the pH value were measured.Futhermore, the decontamination agent CARELA HYDRO-DES, a two component agent based on H(2)O(2) with the addition of a mixture of sodium hydrogen sulphate and sulphuric acid in an aqueous solution effective at 0.1% and higher, was applied in a unit that had been put out of service for a month before. Before application, the system was first filled with a 5% solution of the alkaline pre-cleaning agent CARELA Solvent for bacterial slime; the system was left with this solution for 1 h. The pre-cleaning agent was then completely displaced from the system with tap water and a decontaminating solution of 5% CARELA HYDRO-DES and left in place for 1 h. Drinking water quality level was reached only twice during the control phase. The average values of the dental units ranged between 3,633 CFU/ml and 29,417 c/ml. During the application phase, drinking water level could be achieved in 11 water samples. In another 6 water samples a total colony count of <150 cfu/ml was reached. The average values for the dental units' total colony count ranged between 529 cfu/ml and 87,450 cfu/ml. No significant differences between the control phase and the action phase could be demonstrated. During the control phase, contamination of the water samples with a mold was noticed so that examinations for molds were carried out beyond the scope of the drinking water directive. For this parameter as well, no significant differences between the phases of the study could be shown.The Legionella load of the dental units was low. L. pneumophila were yielded in only 4 out of 130 water samples. During the control phase, twice colony counts at 50 cfu/1,000 ml and 110 cfu/1,000 ml were measured. During the action phase, counts with Legionella spp. could be measured at 5 cfu/1,000 ml for one unit only. Also, with 1-10 cfu/100 ml, the P. aeruginosa contamination was low. During the application phase, it ranged between 0-7 cfu/100 ml.Redox potential and pH value showed a slight decrease during the application phase.Before treatment with CARELA Solvent and CARELA HYDRO-DES, the initial contamination of the total count of bacterial colonies was 1,432 cfu/ml at 22°C and 846 cfu/ml at 36°C as well as >1,000 cfu/100 ml for molds. 1 h after the decontamination, no bacteria and molds could be detected in 1,000 ml of tap water. Despite the fact that the unit was not used any longer, after 7 d the bacterial colony count was 3 cfu/ml at 22°C and 2 cfu/ml at 36°C while molds could not be detected. Even after a rest time of 14 d only 167 cfu/ml or 42 cfu/ml could be yielded. Molds were further not cultivable. A material damage could not be observed. Pertaining to the ActiDes technology's effectiveness, it has to be pointed out that the dental units investigated were those used for dental students' teaching and therefore were clearly less frequently used than clinically used units in a dental practice. This resulted in distinctly longer stagnation periods which favored formation of biofilms. In summary, the ActiDes technology and ActiDes-Blue showed not to be sufficiently effective for the sanitation of contaminated water reservoirs in dental units under aggravated conditions of repeated and longer periods of non-use in connection with longer water stagnation periods. In comparison, the biofilm was sustainably eliminated through the combined application of CARELA(®) Solvent for Bacterial Slime with subsequent decontamination using CARELA(®) HYDRO-DES.

  5. Measurement of protein-like fluorescence in river and waste water using a handheld spectrophotometer.

    PubMed

    Baker, Andy; Ward, David; Lieten, Shakti H; Periera, Ryan; Simpson, Ellie C; Slater, Malcolm

    2004-07-01

    Protein-like fluorescence intensity in rivers increases with increasing anthropogenic DOM inputs from sewerage and farm wastes. Here, a portable luminescence spectrophotometer was used to investigate if this technology could be used to provide both field scientists with a rapid pollution monitoring tool and process control engineers with a portable waste water monitoring device, through the measurement of river and waste water tryptophan-like fluorescence from a range of rivers in NE England and from effluents from within two waste water treatment plants. The portable spectrophotometer determined that waste waters and sewerage effluents had the highest tryptophan-like fluorescence intensity, urban streams had an intermediate tryptophan-like fluorescence intensity, and the upstream river samples of good water quality the lowest tryptophan-like fluorescence intensity. Replicate samples demonstrated that fluorescence intensity is reproducible to +/- 20% for low fluorescence, 'clean' river water samples and +/- 5% for urban water and waste waters. Correlations between fluorescence measured by the portable spectrophotometer with a conventional bench machine were 0.91; (Spearman's rho, n = 143), demonstrating that the portable spectrophotometer does correlate with tryptophan-like fluorescence intensity measured using the bench spectrophotometer.

  6. Concentration data for anthropogenic organic compounds in groundwater, surface water, and finished water of selected community water systems in the United States, 2002-10

    USGS Publications Warehouse

    Carter, Janet M.; Kingsbury, James A.; Hopple, Jessica A.; Delzer, Gregory C.

    2010-01-01

    The National Water-Quality Assessment Program of the U.S. Geological Survey began implementing Source Water-Quality Assessments (SWQAs) in 2001 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used in SWQA studies, source water is the raw (ambient) water collected at the supply well before water treatment (for groundwater) or the raw (ambient) water collected from the river near the intake (for surface water), and finished water is the water that has been treated and is ready to be delivered to consumers. Finished-water samples are collected before the water enters the distribution system. The primary objective of SWQAs is to determine the occurrence of more than 250 anthropogenic organic compounds in source water used by community water systems, many of which currently are unregulated in drinking water by the U.S. Environmental Protection Agency. A secondary objective is to understand recurrence patterns in source water and determine if these patterns also occur in finished water before distribution. SWQA studies were conducted in two phases for most studies completed by 2005, and in one phase for most studies completed since 2005. Analytical results are reported for a total of 295 different anthropogenic organic compounds monitored in source-water and finished-water samples collected during 2002-10. The 295 compounds were classified according to the following 13 primary use or source groups: (1) disinfection by-products; (2) fumigant-related compounds; (3) fungicides; (4) gasoline hydrocarbons, oxygenates, and oxygenate degradates; (5) herbicides and herbicide degradates; (6) insecticides and insecticide degradates; (7) manufacturing additives; (8) organic synthesis compounds; (9) pavement- and combustion-derived compounds; (10) personal-care and domestic-use products; (11) plant- or animal-derived biochemicals; (12) refrigerants and propellants; and (13) solvents. This report presents the analytical results of source- water samples from 448 community water system wells and 21 surface-water sites. This report also presents the analytical results of finished-water samples from 285 wells and 20 surface-water sites from community water systems. Results of quality-assurance/quality-control samples also are presented including data for equipment blanks, field blanks, source solution blanks, and replicate samples.

  7. Effects of rainfall events on the occurrence and detection efficiency of viruses in river water impacted by combined sewer overflows.

    PubMed

    Hata, Akihiko; Katayama, Hiroyuki; Kojima, Keisuke; Sano, Shoichi; Kasuga, Ikuro; Kitajima, Masaaki; Furumai, Hiroaki

    2014-01-15

    Rainfall events can introduce large amount of microbial contaminants including human enteric viruses into surface water by intermittent discharges from combined sewer overflows (CSOs). The present study aimed to investigate the effect of rainfall events on viral loads in surface waters impacted by CSO and the reliability of molecular methods for detection of enteric viruses. The reliability of virus detection in the samples was assessed by using process controls for virus concentration, nucleic acid extraction and reverse transcription (RT)-quantitative PCR (qPCR) steps, which allowed accurate estimation of virus detection efficiencies. Recovery efficiencies of poliovirus in river water samples collected during rainfall events (<10%) were lower than those during dry weather conditions (>10%). The log10-transformed virus concentration efficiency was negatively correlated with suspended solid concentration (r(2)=0.86) that increased significantly during rainfall events. Efficiencies of DNA extraction and qPCR steps determined with adenovirus type 5 and a primer sharing control, respectively, were lower in dry weather. However, no clear relationship was observed between organic water quality parameters and efficiencies of these two steps. Observed concentrations of indigenous enteric adenoviruses, GII-noroviruses, enteroviruses, and Aichi viruses increased during rainfall events even though the virus concentration efficiency was presumed to be lower than in dry weather. The present study highlights the importance of using appropriate process controls to evaluate accurately the concentration of water borne enteric viruses in natural waters impacted by wastewater discharge, stormwater, and CSOs. © 2013.

  8. Rapid screening and identification of chemical hazards in surface and drinking water using high resolution mass spectrometry and a case-control filter.

    PubMed

    Kaserzon, Sarit L; Heffernan, Amy L; Thompson, Kristie; Mueller, Jochen F; Gomez Ramos, Maria Jose

    2017-09-01

    Access to clean, safe drinking water poses a serious challenge to regulators, and requires analytical strategies capable of rapid screening and identification of potentially hazardous chemicals, specifically in situations when threats to water quality or security require rapid investigations and potential response. This study describes a fast and efficient chemical hazard screening strategy for characterising trace levels of polar organic contaminants in water matrices, based on liquid chromatography high resolution mass spectrometry with post-acquisition 'case-control' data processing. This method allowed for a rapid response time of less than 24 h for the screening of target, suspect and non-target unknown chemicals via direct injection analysis, and a second, more sensitive analysis option requiring sample pre-concentration. The method was validated by fortifying samples with a range of pesticides, pharmaceuticals and personal care products (n = 46); with >90% of target compounds positively screened in samples at 1 ng mL -1 , and 46% at 0.1 ng mL -1 when analysed via direct injection. To simulate a contamination event samples were fortified with compounds not present in the commercial library (designated 'non-target compounds'; fipronil and fenitrothion), tentatively identified at 0.2 and 1 ng mL -1 , respectively; and a compound not included in any known commercial library or public database (designated 'unknown' compounds; 8Cl - perfluorooctanesulfonic acid), at 0.8 ng mL -1 . The method was applied to two 'real-case' scenarios: (1) the assessment of drinking water safety during a high-profile event in Brisbane, Australia; and (2) to screen treated, re-circulated drinking water and pre-treated (raw) water. The validated workflow was effective for rapid prioritisation and screening of suspect and non-target potential hazards at trace levels, and could be applied to a wide range of matrices and investigations where comparison of organic contaminants between an affected and control site and or timeframe is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Data on dissolved pesticides and volatile organic compounds in surface and ground waters in the San Joaquin-Tulare basins, California, water years 1992-1995

    USGS Publications Warehouse

    Kinsey, Willie B.; Johnson, Mark V.; Gronberg, JoAnn M.

    2005-01-01

    This report contains pesticide, volatile organic compound, major ion, nutrient, tritium, stable isotope, organic carbon, and trace-metal data collected from 149 ground-water wells, and pesticide data collected from 39 surface-water stream sites in the San Joaquin Valley of California. Included with the ground-water data are field measurements of pH, specific conductance, alkalinity, temperature, and dissolved oxygen. This report describes data collection procedures, analytical methods, quality assurance, and quality controls used by the National Water-Quality Assessment Program to ensure data reliability. Data contained in this report were collected during a four year period by the San Joaquin?Tulare Basins Study Unit of the United States Geological Survey's National Water-Quality Assessment Program. Surface-water-quality data collection began in April 1992, with sampling done three times a week at three sites as part of a pilot study conducted to provide background information for the surface-water-study design. Monthly samples were collected at 10 sites for major ions and nutrients from January 1993 to March 1995. Additional samples were collected at four of these sites, from January to December 1993, to study spatial and temporal variability in dissolved pesticide concentrations. Samples for several synoptic studies were collected from 1993 to 1995. Ground-water-quality data collection was restricted to the eastern alluvial fans subarea of the San Joaquin Valley. Data collection began in 1993 with the sampling of 21 wells in vineyard land-use settings. In 1994, 29 wells were sampled in almond land-use settings and 9 in vineyard land-use settings; an additional 11 wells were sampled along a flow path in the eastern Fresno County vineyard land-use area. Among the 79 wells sampled in 1995, 30 wells were in the corn, alfalfa, and vegetable land-use setting, and 1 well was in the vineyard land-use setting; an additional 20 were flow-path wells. Also sampled in 1995 were 28 wells used for a regional assessment of ground-water quality in the eastern San Joaquin Valley.

  10. Scales and Patterns of Nitrate Transport and Transformation in the Hyporheic Zone of a Lowland River

    NASA Astrophysics Data System (ADS)

    Naden, E.; Krause, S.; Tecklenburg, C.; Munz, M.

    2009-04-01

    The Hyporheic Zone (HZ) represents the spatially and temporally variable part of the streambed that is affected by the mixture of groundwater and surface water and often characterised by strong redox gradients and high turnover rates of redox reactive substances. The HZ has often been understood as a complex bioreactor with a high potential to affect groundwater-surface water exchange as well control the chemical signature of waters along the hyporheic passage. Currently, 73% of groundwater and 28% of UK rivers sampled exhibit either high nitrate levels or rising trends (Defra, 2008) Because of the high metabolic rates that have often be observed, the HZ is by many expected to potentially ameliorate groundwater nitrate fluxes and thus to reduce nitrate pollution and benefit freshwater ecosystems. The objective of this pilot study was to set up a monitoring program on a typical lowland river within glacio-fluvial deposits and well connected to the shallow groundwater aquifer. This study aims to derive a conceptual model of hyporheic exchange and nutrient metabolism in an agriculturally used lowland system including the development of upscaling strategies that allow for the assessment of hyporheic uptake or contribution on a subcatchment scale. The research area covers a 250 metre stream reach of the River Tern (Shropshire, UK), a lowland groundwater dependent surface water body at risk of failing to achieve ‘good water' status under the WFD, primarily due to diffuse agricultural pollution. In two horizontal arrays 42 multi piezometers have been installed in the river bed offering sampling from between three and eight sampling points ranging from 5 cm to 200 cm depth. These allow the sampling of streambed porewater from more than 150 locations. Additionally, ten shallow groundwater boreholes (up to 3m depth) have been installed within the riparian floodplain. From June to September 2008 head measurements were taken at the streambed piezometers, riparian groundwater boreholes and the river in order to determine the groundwater flowfield and exchange with the surface water. At the same time interval streambed pore water and riparian groundwater were sampled from piezometers and boreholes alongside surface water samples from the river. The samples were analysed for dissolved oxygen and major anion concentrations. Initial results confirm indicate that the water sources mixing in the HZ are statistically distinctive. In contrast to the many observed head water streams the exchange between groundwater and surface water is not just determined by gradually changing hydraulic conductivities of the sediment material but strongly controlled by the spatial pattern of a discontinuous impermeable regional peat layer located in 50 cm depth on average. The peat layer is separating the fluxes within the streambed into two (partially connected) flow systems, with semi-confined conditions underneath and pattern of surface water mixing above the peat. Areas where the peat layer is disrupted are characterised by strong connection of both flow systems. Dependent on flow paths and residence times redox conditions and nitrate concentrations are showing substantial changes along the hyporheic flow path. The spatial very heterogeneous patterns of nitrate concentrations in the streambed were found controlled by complex flow processes at multiple scales covering small scale hyporheic exchange in pools, riffles and sand bars as well as large scale pattern of groundwater - surface water connectivity and riparian influences.

  11. Microbial community dynamics of an urban drinking water distribution system subjected to phases of chloramination and chlorination treatments.

    PubMed

    Hwang, Chiachi; Ling, Fangqiong; Andersen, Gary L; LeChevallier, Mark W; Liu, Wen-Tso

    2012-11-01

    Water utilities in parts of the U.S. control microbial regrowth in drinking water distribution systems (DWDS) by alternating postdisinfection methods between chlorination and chloramination. To examine how this strategy influences drinking water microbial communities, an urban DWDS (population ≅ 40,000) with groundwater as the source water was studied for approximately 2 years. Water samples were collected at five locations in the network at different seasons and analyzed for their chemical and physical characteristics and for their microbial community composition and structure by examining the 16S rRNA gene via terminal restriction fragment length polymorphism and DNA pyrosequencing technology. Nonmetric multidimension scaling and canonical correspondence analysis of microbial community profiles could explain >57% of the variation. Clustering of samples based on disinfection types (free chlorine versus combined chlorine) and sampling time was observed to correlate to the shifts in microbial communities. Sampling location and water age (<21.2 h) had no apparent effects on the microbial compositions of samples from most time points. Microbial community analysis revealed that among major core populations, Cyanobacteria, Methylobacteriaceae, Sphingomonadaceae, and Xanthomonadaceae were more abundant in chlorinated water, and Methylophilaceae, Methylococcaceae, and Pseudomonadaceae were more abundant in chloraminated water. No correlation was observed with minor populations that were detected frequently (<0.1% of total pyrosequences), which were likely present in source water and survived through the treatment process. Transient microbial populations including Flavobacteriaceae and Clostridiaceae were also observed. Overall, reversible shifts in microbial communities were especially pronounced with chloramination, suggesting stronger selection of microbial populations from chloramines than chlorine.

  12. Microbial Community Dynamics of an Urban Drinking Water Distribution System Subjected to Phases of Chloramination and Chlorination Treatments

    PubMed Central

    Hwang, Chiachi; Ling, Fangqiong; Andersen, Gary L.; LeChevallier, Mark W.

    2012-01-01

    Water utilities in parts of the U.S. control microbial regrowth in drinking water distribution systems (DWDS) by alternating postdisinfection methods between chlorination and chloramination. To examine how this strategy influences drinking water microbial communities, an urban DWDS (population ≅ 40,000) with groundwater as the source water was studied for approximately 2 years. Water samples were collected at five locations in the network at different seasons and analyzed for their chemical and physical characteristics and for their microbial community composition and structure by examining the 16S rRNA gene via terminal restriction fragment length polymorphism and DNA pyrosequencing technology. Nonmetric multidimension scaling and canonical correspondence analysis of microbial community profiles could explain >57% of the variation. Clustering of samples based on disinfection types (free chlorine versus combined chlorine) and sampling time was observed to correlate to the shifts in microbial communities. Sampling location and water age (<21.2 h) had no apparent effects on the microbial compositions of samples from most time points. Microbial community analysis revealed that among major core populations, Cyanobacteria, Methylobacteriaceae, Sphingomonadaceae, and Xanthomonadaceae were more abundant in chlorinated water, and Methylophilaceae, Methylococcaceae, and Pseudomonadaceae were more abundant in chloraminated water. No correlation was observed with minor populations that were detected frequently (<0.1% of total pyrosequences), which were likely present in source water and survived through the treatment process. Transient microbial populations including Flavobacteriaceae and Clostridiaceae were also observed. Overall, reversible shifts in microbial communities were especially pronounced with chloramination, suggesting stronger selection of microbial populations from chloramines than chlorine. PMID:22941076

  13. Water Quality in Surface Water: A Preliminary Assessment of Heavy Metal Contamination of the Mashavera River, Georgia

    PubMed Central

    Urushadze, Teo

    2018-01-01

    Water quality contamination by heavy metal pollution has severe effects on public health. In the Mashavera River Basin, an important agricultural area for the national food system in Georgia (e.g., vegetable, dairy and wine production), water contamination has multiple influences on the regional and country-wide health. With new industrial activities in the region, sediment extraction, and discharge of untreated wastewater into the river, its tributaries and irrigation canals, a comprehensive study of water quality was greatly needed. This study examined sediment and water samples from 17 sampling sites in the Mashavera River Basin during the high and low precipitation seasons. The results were characterized utilizing the Geo-accumulation Index (Igeo), Enrichment Factor (EF), Pollution Load index (PLI), Contamination Factor (CF) and Metal Index (MI). According to the CFs, Cu > Cd > Zn > Pb > Fe > Mn > Ni > Cr > Hg is the descending order for the content of all observed heavy metals in sediments collected in both seasons. Fe and As were additionally examined in water samples. Overall, As, Cd and Pb, all highly toxic elements, were found in high concentrations in downstream sample sites. According to these results, comprehensive monitoring with narrow intervals between sampling dates, more sample sites along all waterways, and proximate observation of multiple trace metal elements are highly recommended. Moreover, as the part of the water quality governance system, an immediate and sustainable collective action by all stakeholders to control the pollution level is highly recommended, as this issue is linked to the security of the national food system and poses a local public health risk. PMID:29597320

  14. Natural fluoride levels in the drinking water, water fluoridation and estimated risk of dental fluorosis in a tropical region of Brazil.

    PubMed

    Sampaio, Fábio Correia; Silva, Fábia Danielle; Silva, Andréa Cristina; Machado, Ana Thereza; de Araújo, Demétrius Antônio; de Sousa, Erik Melo

    2010-01-01

    The aim of the present study was to determine the natural fluoride levels in the drinking water supplies of a tropical area of Brazil to identify the cities at risk of high prevalence of dental fluorosis and to provide data for future water fluoridation projects in the region. The present study was carried out in Paraíba, in the north-eastern region of Brazil. A total of 223 cities were selected, and local health workers were instructed to collect three samples of drinking water: one from the main public water supply and the other two from a public or residential tap with the same water source. Fluoride analyses were carried out in duplicate using a fluoride-specific electrode coupled to an ion analyser. A total of 167 cities (75%) provided water samples for analysis. Fluoride levels ranged from 0.1 to 1.0 ppm (mg/l). Samples from most of the cities (n = 163, 73%) presented low levels of fluoride (< 0.5 mg/l). Samples from three cities (a total estimate of 28,222 inhabitants exposed) presented 'optimum' fluoride levels (0.6 to 0.8 mg/l). Samples from one city (16,724 inhabitants) with 1.0 mg/l of fluoride in the water were above the recommended level (0.7 mg/l) for the local temperature. It can be concluded that the cities in this area of Brazil presented low natural fluoride levels in the drinking water and could implement controlled water fluoridation projects when technical requirements are accomplished. A high or a moderate prevalence of dental fluorosis due to the intake of natural fluoride in the drinking water is likely to take place in one city only.

  15. Characterizing spatiotemporal variations of chromophoric dissolved organic matter in headwater catchment of a key drinking water source in China.

    PubMed

    Chen, Yihan; Yu, Kaifeng; Zhou, Yongqiang; Ren, Longfei; Kirumba, George; Zhang, Bo; He, Yiliang

    2017-12-01

    Natural surface drinking water sources with the increasing chromophoric dissolved organic matter (CDOM) have profound influences on the aquatic environment and drinking water safety. Here, this study investigated the spatiotemporal variations of CDOM in Fengshuba Reservoir and its catchments in China. Twenty-four surface water samples, 45 water samples (including surface water, middle water, and bottom water), and 15 pore water samples were collected from rivers, reservoir, and sediment of the reservoir, respectively. Then, three fluorescent components, namely two humic-like components (C1 and C2) and a tryptophan-like component (C3), were identified from the excitation-emission matrix coupled with parallel factor analysis (EEM-PARAFAC) for all samples. For spatial distributions, the levels of CDOM and two humic-like components in the reservoir were significantly lower than those in the upstream rivers (p < 0.01), indicating that the reservoir may act as a reactor to partly reduce the levels of exogenous input including CDOM and humic-like matters from the surrounding catchment. For temporal variations, the mean levels of CDOM and three fluorescent components did not significantly change in rivers, suggesting that perennial anthropic activity maybe an important factor impacting the concentration and composition of river CDOM but not the precipitation and runoff. However, these mean values of CDOM for the bulk waters of the reservoir changed markedly along with seasonal variations, indicating that the hydrological processes in the reservoir could control the quality and quantity of CDOM. The different correlations between the fluorescent components and primary water parameters in the river, reservoir, and pore water samples further suggest that the reservoir is an important factor regulating the migration and transformation of FDOM along with the variations of different environmental gradients.

  16. Point-of-Use Interventions to Decrease Contamination of Drinking Water: A Randomized, Controlled Pilot Study on Efficacy, Effectiveness, and Acceptability of Closed Containers, Moringa oleifera, and In-home Chlorination in Rural South India

    PubMed Central

    Firth, Jacqueline; Balraj, Vinohar; Muliyil, Jayaprakash; Roy, Sheela; Rani, Lilly Michael; Chandresekhar, R.; Kang, Gagandeep

    2010-01-01

    To assess water contamination and the relative effectiveness of three options for point-of-use water treatment in South India, we conducted a 6-month randomized, controlled intervention trial using chlorine, Moringa oleifera seeds, a closed valved container, and controls. One hundred twenty-six families participated. Approximately 70% of public drinking water sources had thermotolerant coliform counts > 100/100 mL. Neither M. oleifera seeds nor containers reduced coliform counts in water samples from participants' homes. Chlorine reduced thermotolerant coliform counts to potable levels, but was less acceptable to participants. Laboratory testing of M. oleifera seeds in water from the village confirmed the lack of reduction in coliform counts, in contrast to the improvement seen with Escherichia coli seeded distilled water. This discrepancy merits further study, as M. oleifera was effective in reducing coliform counts in other studies and compliance with Moringa use in this study was high. PMID:20439952

  17. Point-of-use interventions to decrease contamination of drinking water: a randomized, controlled pilot study on efficacy, effectiveness, and acceptability of closed containers, Moringa oleifera, and in-home chlorination in rural South India.

    PubMed

    Firth, Jacqueline; Balraj, Vinohar; Muliyil, Jayaprakash; Roy, Sheela; Rani, Lilly Michael; Chandresekhar, R; Kang, Gagandeep

    2010-05-01

    To assess water contamination and the relative effectiveness of three options for point-of-use water treatment in South India, we conducted a 6-month randomized, controlled intervention trial using chlorine, Moringa oleifera seeds, a closed valved container, and controls. One hundred twenty-six families participated. Approximately 70% of public drinking water sources had thermotolerant coliform counts > 100/100 mL. Neither M. oleifera seeds nor containers reduced coliform counts in water samples from participants' homes. Chlorine reduced thermotolerant coliform counts to potable levels, but was less acceptable to participants. Laboratory testing of M. oleifera seeds in water from the village confirmed the lack of reduction in coliform counts, in contrast to the improvement seen with Escherichia coli seeded distilled water. This discrepancy merits further study, as M. oleifera was effective in reducing coliform counts in other studies and compliance with Moringa use in this study was high.

  18. Ex vivo regenerative effects of a spring water.

    PubMed

    Nicoletti, Giovanni; Saler, Marco; Pellegatta, Tommaso; Tresoldi, Marco Mario; Bonfanti, Viola; Malovini, Alberto; Faga, Angela; Riva, Federica

    2017-12-01

    Previous experiments by our group have indicated the regenerative effects of a spring water (Comano), which was possibly associated with the native non-pathogenic bacterial flora. The present study aimed to confirm these regenerative properties in a human ex vivo experimental model in the context of physiological wound healing. Human 6-mm punch skin biopsies harvested during plastic surgery sessions were injured in their central portion to induce skin loss and were cultured in either conventional medium (controls) or medium powder reconstituted with filtered Comano spring water (treated samples). At 24, 48 and 72 h the specimens were observed following staining with hematoxylin and eosin, Picrosirius Red, orcein and anti-proliferating cell nuclear antigen. Compared with the controls, the treated samples exhibited reduced overall cell infiltration, evidence of fibroblasts, stimulation of cell proliferation and collagen and elastic fiber regeneration. In the spring water, in addition to 12 resident non-pathogenic bacterial strains exhibiting favorable metabolic activities, more unknown non-pathogenic species are being identified by genomic analysis. In the present study, the efficacy of this 'germ-free', filtered spring water in wound regeneration was indicated. Thus, the Comano spring water microbiota should be acknowledged for its regenerative properties.

  19. Rapid molecular detection of invasive species in ballast and harbor water by integrating environmental DNA and light transmission spectroscopy.

    PubMed

    Egan, Scott P; Grey, Erin; Olds, Brett; Feder, Jeffery L; Ruggiero, Steven T; Tanner, Carol E; Lodge, David M

    2015-04-07

    Invasive species introduced via the ballast water of commercial ships cause enormous environmental and economic damage worldwide. Accurate monitoring for these often microscopic and morphologically indistinguishable species is challenging but critical for mitigating damages. We apply eDNA sampling, which involves the filtering and subsequent DNA extraction of microscopic bits of tissue suspended in water, to ballast and harbor water sampled during a commercial ship's 1400 km voyage through the North American Great Lakes. Using a lab-based gel electrophoresis assay and a rapid, field-ready light transmission spectroscopy (LTS) assay, we test for the presence of two invasive species: quagga (Dreissena bugensis) and zebra (D. polymorpha) mussels. Furthermore, we spiked a set of uninfested ballast and harbor samples with zebra mussel tissue to further test each assay's detection capabilities. In unmanipulated samples, zebra mussel was not detected, while quagga mussel was detected in all samples at a rate of 85% for the gel assay and 100% for the LTS assay. In the spiked experimental samples, both assays detected zebra mussel in 94% of spiked samples and 0% of negative controls. Overall, these results demonstrate that eDNA sampling is effective for monitoring ballast-mediated invasions and that LTS has the potential for rapid, field-based detection.

  20. Effects of drinking water quality on urinary parameters in men with and without urinary tract stones.

    PubMed

    Mirzazadeh, Majid; Nouran, Mina Ghadimi; Richards, Kyle A; Zare, Mariam

    2012-03-01

    There is some controversy regarding the impact of water hardness on stone risk. Our study addresses this issue in a controlled setting. Fifteen stone-former (SF) and 14 non-stone-former (NSF) males participated in this study in 3 intervals of 2 days each. Subjects collected a 24-hour urine sample while consuming a self-selected diet. They were then administered controlled diets. During the first 2 days, patients consumed water of minimal hardness (WMH), followed by tap water (TW) with moderate hardness on days 3 and 4, and mineral water (MW) on the final 2 days. Calcium (Ca), phosphorus, uric acid, oxalate, citrate, magnesium (Mg), sodium, potassium, and creatinine (Cr) content were measured in 24-hour urine samples on days 2, 4, and 6. Differences in water hardness and analytes were statistically significant among the different water types (P < .05). Urinary output in both groups increased during intervention with all 3 varieties of water (P < .05). Specific gravity of urine decreased in both groups drinking WMH and TW (P < .05) but not with MW. Mg/g Cr level was higher in NSF at baseline (P < .01), WMH (P < .05), and TW (P < .05). With the increase in drinking water hardness, Ca/g Cr ratio increased in SF but not in NSF (P < .05). NSF had significantly higher urinary Mg/g Cr excretion rate before intervention than SF (P < .01). Increasing drinking water hardness while controlling for all other factors increased Ca/g Cr ratio in SF, rendering them at least theoretically more inclined to stone formation. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  2. Buoyancy-corrected gravimetric analysis of lightly loaded filters.

    PubMed

    Rasmussen, Pat E; Gardner, H David; Niu, Jianjun

    2010-09-01

    Numerous sources of uncertainty are associated with the gravimetric analysis of lightly loaded air filter samples (< 100 microg). The purpose of the study presented here is to investigate the effectiveness and limitations of air buoyancy corrections over experimentally adjusted conditions of temperature (21-25 degrees C) and relative humidity (RH) (16-60% RH). Conditioning (24 hr) and weighing were performed inside the Archimedes M3 environmentally controlled chamber. The measurements were performed using 20 size-fractionated samples of resuspended house dust loaded onto Teflo (PTFE) filters using a Micro-Orifice Uniform Deposit Impactor representing a wide range of mass loading (7.2-3130 microg) and cut sizes (0.056-9.9 microm). By maintaining tight controls on humidity (within 0.5% RH of control setting) throughout pre- and postweighing at each stepwise increase in RH, it was possible to quantify error due to water absorption: 45% of the total mass change due to water absorption occurred between 16 and 50% RH, and 55% occurred between 50 and 60% RH. The buoyancy corrections ranged from -3.5 to +5.8 microg in magnitude and improved relative standard deviation (RSD) from 21.3% (uncorrected) to 5.6% (corrected) for a 7.2 microg sample. It is recommended that protocols for weighing low-mass particle samples (e.g., nanoparticle samples) should include buoyancy corrections and tight temperature/humidity controls. In some cases, conditioning times longer than 24 hr may be warranted.

  3. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    NASA Technical Reports Server (NTRS)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  4. Preliminary geochemical, microbiological, and epidemiological investigations into possible linkages between lignite aquifers, pathogenic microbes, and kidney disease in northwestern Louisiana

    USGS Publications Warehouse

    Bunnell, Joseph E.; Bushon, Rebecca N.; Stoeckel, Donald M.; Gifford, Amie M.; Beck, Marisa; Lerch, Harry E.; Shi, Runhua; McGee, Benton; Hanson, Bradford C.; Kolak, Jonathan; Warwick, Peter D.

    2003-01-01

    In May 2002, 15 wells and four surface water sites were sampled, and in September 2002, those same wells and sites plus four additional surface sites were sampled in five parishes of northwestern Louisiana. A geographic information system (GIS) was used to select residential water wells for sampling. Well water samples were analyzed for pH, conductivity, organic compounds, and nutrient and anion concentrations. All samples were further tested for presence of fungi (maintained for up to 28 days and colonies counted and identified microscopically), and metal and trace element concentration by inductively-coupled plasma mass spectrometry and atomic emission spectrometry. Surface water samples were tested for dissolved oxygen and evidence of leptospiral bacterial presence. A polymerase chain reaction protocol was optimized for detection of pathogenic leptospires, and the sensitivity of the assay was determined. The Spearman correlation method was used to assess the association between the endpoints for these field/laboratory analyses and the incidence of cancer of the renal pelvis obtained from the Louisiana Tumor Registry. Significant associations were revealed between the cancer rate and the overall number of organic compounds, the fungi Zygomycetes, the nutrients PO4 and NH3, and thirteen chemical elements (As, B, Br, Cl, Cr, F, Li, Na, P, Rb, Se, Sr, W) from the well water as compared to the controls. Among the species of fungi from the total of 136 isolates were 12 Penicillium spp., at least two Aspergillus spp., a number of other genera (Alternaria sp., Eupenicillium lapidosum, Cladosporium sp., Epicoccum sp., Trichoderma sp., Paecilomyces sp., Chrysosporium sp., Chloridium sp.), and Zygomycetes, and Coelmycetes -- some of which are known mycotoxin producers. The two control wells yielded a mean of 6.5 (SD = 3.5355) individual isolates, while the mean number of isolates from all other sites was 7.6 (SD = 4.4866). Presence of human pathogenic leptospires was detected in 4/8 (50 percent) of the surface water sites sampled. These initial results suggest that additional investigation into these relationships is warranted.

  5. Sequential derivatization of polar organic compounds in cloud water using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride, N,O-bis(trimethylsilyl)trifluoroacetamide, and gas-chromatography/mass spectrometry analysis.

    PubMed

    Sagona, Jessica A; Dukett, James E; Hawley, Harmonie A; Mazurek, Monica A

    2014-10-03

    Cloud water samples from Whiteface Mountain, NY were used to develop a combined sampling and gas chromatography-mass spectrometric (GCMS) protocol for evaluating the complex mixture of highly polar organic compounds (HPOC) present in this atmospheric medium. Specific HPOC of interest were mono- and di keto-acids which are thought to originate from photochemical reactions of volatile unsaturated hydrocarbons from biogenic and manmade emissions and be a major fraction of atmospheric carbon. To measure HPOC mixtures and the individual keto-acids in cloud water, samples first must be derivatized for clean elution and measurement, and second, have low overall background of the target species as validated by GCMS analysis of field and laboratory blanks. Here, we discuss a dual derivatization method with PFBHA and BSTFA which targets only organic compounds that contain functional groups reacting with both reagents. The method also reduced potential contamination by minimizing the amount of sample processing from the field through the GCMS analysis steps. Once derivatized only gas chromatographic separation and selected ion monitoring (SIM) are needed to identify and quantify the polar organic compounds of interest. Concentrations of the detected total keto-acids in individual cloud water samples ranged from 27.8 to 329.3ngmL(-1) (ppb). Method detection limits for the individual HPOC ranged from 0.17 to 4.99ngmL(-1) and the quantification limits for the compounds ranged from 0.57 to 16.64ngmL(-1). The keto-acids were compared to the total organic carbon (TOC) results for the cloud water samples with concentrations of 0.607-3.350mgL(-1) (ppm). GCMS analysis of all samples and blanks indicated good control of the entire collection and analysis steps. Selected ion monitoring by GCMS of target keto-acids was essential for screening the complex organic carbon mixtures present at low ppb levels in cloud water. It was critical for ensuring high levels of quality assurance and quality control and for the correct identification and quantification of key marker compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Management of Chronic Periodontitis Using Subgingival Irrigation of Ozonized Water: A Clinical and Microbiological Study.

    PubMed

    Issac, Annie V; Mathew, Jayan Jacob; Ambooken, Majo; Kachappilly, Arun Jose; Pk, Ajithkumar; Johny, Thomas; Vk, Linith; Samuel, Anju

    2015-08-01

    Adjunctive use of professional subgingival irrigation with scaling and root planing (SRP) has been found to be beneficial in eradicating the residual microorganisms in the pocket. To evaluate the effect of ozonized water subgingival irrigation on microbiologic parameters and clinical parameters namely Gingival index, probing pocket depth, and clinical attachment level. Thirty chronic periodontitis patients with probing pocket depth ≥6mm on at least one tooth on contra lateral sides of opposite arches were included in the study. The test sites were subjected to ozonized water subgingival irrigation with subgingival irrigation device fitted with a modified subgingival tip. Control sites were subjected to scaling and root planing only. The following clinical parameters were recorded initially and after 4 weeks at the test sites and control sites. Plaque Index, Gingival Index, probing pocket depth, clinical attachment level. Microbiologic sampling was done for the test at the baseline, after scaling, immediately after ozonized water subgingival irrigation and after 4 weeks. In control sites microbiologic sampling was done at the baseline, after scaling and after 4 weeks. The following observations were made after 4 weeks. The results were statistically analysed using independent t-test and paired t-test. Test sites showed a greater reduction in pocket depth and gain in clinical attachment compared to control sites. The total anaerobic counts were significantly reduced by ozonized water subgingival irrigation along with SRP compared to SRP alone. Ozonized water subgingival irrigation can improve the clinical and microbiological parameters in patients with chronic periodontitis when used as an adjunct to scaling and root planing.

  7. Groundwater Quality Data in the Mojave Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 1,500 square-mile Mojave (MOJO) study unit was investigated from February to April 2008, as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). MOJO was the 23rd of 37 study units to be sampled as part of the GAMA Priority Basin Project. The MOJO study was designed to provide a spatially unbiased assessment of the quality of untreated ground water used for public water supplies within MOJO, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 59 wells in San Bernardino and Los Angeles Counties. Fifty-two of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and seven were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, and pharmaceutical compounds], constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]) naturally occurring inorganic constituents (nutrients, dissolved organic carbon [DOC], major and minor ions, silica, total dissolved solids [TDS], and trace elements), and radioactive constituents (gross alpha and gross beta radioactivity, radium isotopes, and radon-222). Naturally occurring isotopes (stable isotopes of hydrogen, oxygen, and carbon, stable isotopes of nitrogen and oxygen in nitrate, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 230 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 5-8 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptable analytical reproducibility. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated ground water. However, to provide some context for the results, concentrations of constituents measured in the untreated ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking-water are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. Most constituents that were detected in groundwater samples in the 59 wells in MOJO were found at concentrations below drinking-water thresholds. In MOJO's 52 grid wells, volatile organic compounds (VOCs) were detected in 40 percent of the wells, and pesticides and pesticide degradates were detected in 23 percent of the grid wel

  8. The relationship between land management, fecal indicator bacteria, and the occurrence of Campylobacter and Listeria spp. in water and sediments during synoptic sampling in the S. Fork Broad River Watershed, N.E. Georgia, U.S.A

    NASA Astrophysics Data System (ADS)

    Bradshaw, J. K.; Molina, M.; Sidle, R. C.; Sullivan, K.; Oakley, B.; Berrang, M.; Meinersmann, R.

    2013-12-01

    Fecal indicator bacteria (FIB) and pathogens stored in the bed sediments of streams and rivers may be mobilized into the water column affecting overall water quality. Furthermore, land management may play an important role in the concentrations of FIB and the occurrence of pathogens in stream water and sediments. The purpose of this study was to determine the relationship between FIB and pathogens in stream water and sediment based on three land management-affected categories: agricultural, forest, and waters receiving treated municipal wastewater. Two synoptic sampling events were conducted under baseflow conditions (<0.64 cm of rain within 24h) between October-November, 2012 and May-June, 2013. Counts of the E. coli and E. faecalis and occurrences of the enteric pathogens Campylobacter and Listeria spp. were measured in stream water and sediment samples collected at 15 locations (six agricultural (AG); six forested (FORS); and three receiving discharge from water pollution control plants (WPCP)) in the S. Fork Broad River watershed located in northeast Georgia, USA. Mean E. coli and E. faecalis concentrations were highest in the AG stream water samples (3.08 log MPN 100 mL -1 for E. coli and 3.07 log CFU 100 mL -1 for E. faecalis ) and lowest in the FORS water samples for E. coli (2.37 log MPN 100 mL -1 ) and WPCP water samples for E. faecalis (2.53 log CFU 100 mL -1 ). E. coli concentrations (2.74 log MPN 100 mL -1 ) in the WPCP streams were intermediate. Similar to water samples, E. coli concentrations were highest in the AG sediments (4.31 log MPN g -1 ), intermediate in the WPCP sediments (4.06 log MPN g -1 ), and lowest in the FORS sediments (3.46 log MPN g -1 ). In contrast to E. coli, E. faecalis concentrations were lower (1.10 to 1.31 log CFU g -1 ) and relatively more constant than E. coli in sediments over the three land management categories. Campylobacter was detected in 27% of the water samples and 8% of the sediment samples. The highest occurrence of Campylobacter detection was in the AG streams (15% of the water samples; 5% of the sediment samples). Listeria was detected in 76% of the water samples and 65% of the sediment samples. The FORS and AG streams had the highest occurrence of Listeria in water and sediment (32% and 29% of the water samples, respectively; 24% and 29% of sediment samples, respectively) suggesting Listeria is fairly ubiquitous in these streams. Based on the high concentrations of E. faecalis in water and E. coli in water and sediment, and higher frequency of Campylobacter detection in the AG streams, this study indicates that E. coli and Campylobacter may occur in high concentrations in stream sediments in land management areas where fecal material is deposited directly by livestock into the stream or adjacent land in large doses.

  9. Radon and temperature as tracer of geothermal flow system: application to Arxan geothermal system, Northeastern China

    NASA Astrophysics Data System (ADS)

    Gu, X.; Shao, J.; Cui, Y.

    2017-12-01

    In this work, hydrogeological and hydrochemical investigations were applied to explain geothermal system factors controlling groundwater mineralization in Arxan geothermal system, Northeastern China. Geothermal water samples were collected from different locations (thermal baths and wells). Radon concentrations of water samples representing different water types and depths were controlled using RAD7. In addition to radon concentration, physical parameters such as temperature (T), pH, electrical conductivity (EC) and TDS were measured in situ, while major ions were analyzed in laboratory. Temperature spatial variability in the study area was described using kriging interpolation method. Hydrochemical analysis and thermal parameters suggest two distinct hydrogeological systems. The first type was dominated by a moderate temperature (25 41°C) with a chemical facies Na-HCO3, which characterizes Jurassic deep water. The second water type was characterized by Ca.Na-HCO3 type with a temperature <25 °C and represents the shallow aquifer. Superficial aquifer displays higher radon concentration (37 to 130 Bq/L), while deep groundwater from Jurassic aquifer shows relatively a low radon concentration (6 to 57.4 Bq/L). Seasonal and geographical variations of radon give insight into the processes controlling radon activities in the Arxan groundwater. Radon concentrations along with spatial distribution of water temperature reveal the existence of vertical communication between shallow aquifer and deep Jurassic aquifer through vertical faults and fractures system, the emanation of radon from thermal water and groundwater is controlled by the geological structure of the area. Furthermore, the knowledge and conclusion demonstrates that combined use of radon and temperature as tracers can give insight into the characteristics of geological structure and geothermal flow system.

  10. Availability of safe drinking-water: the answer to cholera outbreak? Nabua, Camarines Sur, Philippines, 2012.

    PubMed

    De Guzman, Alethea; de los Reyes, Vikki Carr; Sucaldito, Ma Nemia; Tayag, Enrique

    2015-01-01

    In May 2012, there were increasing diarrhoea cases and deaths reported from Nabua, Camarines Sur to the Philippines event-based surveillance system. An investigation was conducted to identify risk factors and determine transmission dynamics. A suspected case was defined as a resident of Nabua with at least three episodes of watery diarrhoea per day from 16 March to 22 June 2012. A confirmed case was defined as a suspected case positive for Vibrio cholerae. An environmental investigation was conducted and rectal swabs and water samples sent to the national reference laboratory for bacterial isolation. A 1:2 case-control study matching for age and sex was conducted. Data were analysed using Epi Info. There were 309 suspected cases with two deaths, and the most affected age group was children under five years (45%). Eight cases were positive for Vibrio cholerae Ogawa El Tor and one for Non-01. Water samples were positive for faecal coliforms and Aeromonas caviae. The case-control study showed that cases had a higher odds than controls of using unchlorinated water sources (odds ratio [OR] = 3.6; 95% confidence interval [CI]:1.6-8.5) and having toilets located within 20 m of a septic tank (OR = 2.7; 95% CI: 1.4-5.3). In multivariate analysis, the only significant factor was drinking from piped water (OR = 0.21; 95% CI: 0.09-0.49). In this cholera outbreak, drinking-water from unchlorinated wells was a significant risk factor. Future cholera control efforts should include not just improving water and sanitation systems but also intensified behaviour change campaigns.

  11. CALIFORNIA'S FIRST AERATION PLANTS FOR CORROSION CONTROL

    EPA Science Inventory

    As required by the Lead and Copper Rule (LCR), Idyllwild Water District (IWD) and Pine Cove Water District (PCWD) conducted a sampling and testing program in 1993-1994. The program began with an evaluation of local household plumbing to identify 20 sites in each District which wo...

  12. 40 CFR 141.80 - General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.80 General requirements. (a... drinking water regulations for lead and copper. Unless otherwise indicated, each of the provisions of this... and copper action levels measured in samples collected at consumers' taps. (c) Lead and copper action...

  13. Temperature-controlled micro-TLC: a versatile green chemistry and fast analytical tool for separation and preliminary screening of steroids fraction from biological and environmental samples.

    PubMed

    Zarzycki, Paweł K; Slączka, Magdalena M; Zarzycka, Magdalena B; Bartoszuk, Małgorzata A; Włodarczyk, Elżbieta; Baran, Michał J

    2011-11-01

    This paper is a continuation of our previous research focusing on development of micro-TLC methodology under temperature-controlled conditions. The main goal of present paper is to demonstrate separation and detection capability of micro-TLC technique involving simple analytical protocols without multi-steps sample pre-purification. One of the advantages of planar chromatography over its column counterpart is that each TLC run can be performed using non-previously used stationary phase. Therefore, it is possible to fractionate or separate complex samples characterized by heavy biological matrix loading. In present studies components of interest, mainly steroids, were isolated from biological samples like fish bile using single pre-treatment steps involving direct organic liquid extraction and/or deproteinization by freeze-drying method. Low-molecular mass compounds with polarity ranging from estetrol to progesterone derived from the environmental samples (lake water, untreated and treated sewage waters) were concentrated using optimized solid-phase extraction (SPE). Specific bands patterns for samples derived from surface water of the Middle Pomerania in northern part of Poland can be easily observed on obtained micro-TLC chromatograms. This approach can be useful as simple and non-expensive complementary method for fast control and screening of treated sewage water discharged by the municipal wastewater treatment plants. Moreover, our experimental results show the potential of micro-TLC as an efficient tool for retention measurements of a wide range of steroids under reversed-phase (RP) chromatographic conditions. These data can be used for further optimalization of SPE or HPLC systems working under RP conditions. Furthermore, we also demonstrated that micro-TLC based analytical approach can be applied as an effective method for the internal standard (IS) substance search. Generally, described methodology can be applied for fast fractionation or screening of the whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in biological or environmental samples. Due to low consumption of eluent (usually 0.3-1mL/run) mainly composed of water-alcohol binary mixtures, this method can be considered as environmentally friendly and green chemistry focused analytical tool, supplementary to analytical protocols involving column chromatography or planar micro-fluidic devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Evaluating water deficit and glyphosate treatment on the accumulation of phenolic compounds and photosynthesis rate in transgenic Codonopsis lanceolata (Siebold & Zucc.) Trautv. over-expressing γ-tocopherol methyltransferase (γ-tmt) gene.

    PubMed

    Ghimire, Bimal Kumar; Son, Na-Young; Kim, Seung-Hyun; Yu, Chang Yeon; Chung, Ill-Min

    2017-07-01

    The effect of water stress and herbicide treatment on the phenolic compound concentration and photosynthesis rate in transgenic Codonopsis lanceolata plants over-expressing the γ-tmt gene was investigated and compared to that in control non-transgenic C. lanceolata plants. The total phenolic compound content was investigated using high-performance liquid chromatography combined with diode array detection in C. lanceolata seedlings 3 weeks after water stress and treatment with glyphosate. Changes in the composition of phenolic compounds were observed in leaf and root extracts from transformed C. lanceolata plants following water stress and treatment with glyphosate. The total concentration of phenolic compounds in the leaf extracts of transgenic samples after water stress ranged from 3455.13 ± 40.48 to 8695.00 ± 45.44 µg g -1 dry weight (DW), whereas the total concentration phenolic compound in the leaf extracts of non-transgenic control samples was 5630.83 ± 45.91 µg g -1  DW. The predominant phenolic compounds that increased after the water stress in the transgenic leaf were (+) catechin, benzoic acid, chlorogenic acid, ferulic acid, gallic acid, rutin, vanillic acid, and veratric acid. The total concentration of phenolic compounds in the leaf extracts of transgenic samples after glyphosate treatment ranged from 4744.37 ± 81.81 to 12,051.02 ± 75.00 µg g -1 DW, whereas the total concentration of the leaf extracts of non-transgenic control samples after glyphosate treatment was 3778.28 ± 59.73 µg g -1 DW. Major phenolic compounds that increased in the transgenic C. lanceolata plants after glyphosate treatment included kaempherol, gallic acid, myricetin, p-hydroxybenzjoic acid, quercetin, salicylic acid, t-cinnamic acid, catechin, benzoicacid, ferulic acid, protocatechuic acid, veratric acid, and vanillic acid. Among these, vanillic acid showed the greatest increase in both leaf and root extracts from transgenic plants relative to those from control C. lanceolata plants following treatment with glyphosate, which could affect the 5-enol-pyruvyl shikimate-3-phosphate (EPSP) synthase, an enzyme in the shikimate pathway. We observed enhanced stomatal conductance (gs) and photosynthesis rate (A) in the transgenic plants treated with water stress and glyphosate treatment. The results of this study demonstrated large variations in the functioning of secondary metabolites pathway in response glyphosate and water stress in transgenic C. lanceolata.

  15. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2003 to June 30, 2004

    USGS Publications Warehouse

    Young, Stacie T.M.; Ball, Marcael T.J.

    2004-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two sites, continuous streamflow data at three sites, and water-quality data at five sites, which include the three streamflow sites. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2003 and June 30, 2004. A total of 30 samples was collected over four storms during July 1, 2003 to June 30, 2004. In general, an attempt was made to collect grab samples nearly simultaneously at all five sites, and flow-weighted time-composite samples were collected at the three sites equipped with automatic samplers. However, all four storms were partially sampled because either not all stations were sampled or only grab samples were collected. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, copper, lead, and zinc). Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples, collected during storms and during routine maintenance, were also collected to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  16. Quality-assurance plan for the analysis of fluvial sediment by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory

    USGS Publications Warehouse

    Shreve, Elizabeth A.; Downs, Aimee C.

    2005-01-01

    This report describes laboratory procedures used by the U.S. Geological Survey Kentucky Water Science Center Sediment Laboratory for the processing and analysis of fluvial-sediment samples for concentration of sand and finer material. The report details the processing of a sediment sample through the laboratory from receiving the sediment sample, through the analytical process, to compiling results of the requested analysis. Procedures for preserving sample integrity, calibrating and maintaining of laboratory and field instruments and equipment, analyzing samples, internal quality assurance and quality control, and validity of the sediment-analysis results also are described. The report includes a list of references cited and a glossary of sediment and quality-assurance terms.

  17. Determination of total arsenic and arsenic species in drinking water, surface water, wastewater, and snow from Wielkopolska, Kujawy-Pomerania, and Lower Silesia provinces, Poland.

    PubMed

    Komorowicz, Izabela; Barałkiewicz, Danuta

    2016-09-01

    Arsenic is a ubiquitous element which may be found in surface water, groundwater, and drinking water. In higher concentrations, this element is considered genotoxic and carcinogenic; thus, its level must be strictly controlled. We investigated the concentration of total arsenic and arsenic species: As(III), As(V), MMA, DMA, and AsB in drinking water, surface water, wastewater, and snow collected from the provinces of Wielkopolska, Kujawy-Pomerania, and Lower Silesia (Poland). The total arsenic was analyzed by inductively coupled plasma mass spectrometry (ICP-MS), and arsenic species were analyzed with use of high-performance liquid chromatography inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Obtained results revealed that maximum total arsenic concentration determined in drinking water samples was equal to 1.01 μg L(-1). The highest concentration of total arsenic in surface water, equal to 3778 μg L(-1) was determined in Trująca Stream situated in the area affected by geogenic arsenic contamination. Total arsenic concentration in wastewater samples was comparable to those determined in drinking water samples. However, significantly higher arsenic concentration, equal to 83.1 ± 5.9 μg L(-1), was found in a snow sample collected in Legnica. As(V) was present in all of the investigated samples, and in most of them, it was the sole species observed. However, in snow sample collected in Legnica, more than 97 % of the determined concentration, amounting to 81 ± 11 μg L(-1), was in the form of As(III), the most toxic arsenic species.

  18. Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.

    PubMed

    Ji, Xue-Yue; Fei, Chun-Nan; Zhang, Ying; Zhang, Wei; Liu, Jun; Dong, Jie

    2016-08-01

    Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment. © 2016 FDI World Dental Federation.

  19. Accurate mass screening and identification of emerging contaminants in environmental samples by liquid chromatography-hybrid linear ion trap Orbitrap mass spectrometry.

    PubMed

    Hogenboom, A C; van Leerdam, J A; de Voogt, P

    2009-01-16

    The European Reach legislation will possibly drive producers to develop newly designed chemicals that will be less persistent, bioaccumulative or toxic. If this innovation leads to an increased use of more hydrophilic chemicals it may result in higher mobilities of chemicals in the aqueous environment. As a result, the drinking water companies may face stronger demands on removal processes as the hydrophilic compounds inherently are more difficult to remove. Monitoring efforts will also experience a shift in focus to more water-soluble compounds. Screening source waters on the presence of (emerging) contaminants is an essential step in the control of the water cycle from source to tap water. In this article, some of our experiences are presented with the hybrid linear ion trap (LTQ) FT Orbitrap mass spectrometer, in the area of chemical water analysis. A two-pronged strategy in mass spectrometric research was employed: (i) exploring effluent, surface, ground- and drinking-water samples searching for accurate masses corresponding to target compounds (and their product ions) known from, e.g. priority lists or the scientific literature and (ii) full-scan screening of water samples in search of 'unknown' or unexpected masses, followed by MS(n) experiments to elucidate the structure of the unknowns. Applications of both approaches to emerging water contaminants are presented and discussed. Results are presented for target analysis search for pharmaceuticals, benzotriazoles, illicit drugs and for the identification of unknown compounds in a groundwater sample and in a polar extract of a landfill soil sample (a toxicity identification evaluation bioassay sample). The applications of accurate mass screening and identification described in this article demonstrate that the LC-LTQ FT Orbitrap MS is well equipped to meet the challenges posed by newly emerging polar contaminants.

  20. Fate and transport of plutonium-239 + 240 and Americium-241 in the soil of Rocky Flats, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litaor, M.I.; Barth, G.R.; Zika, E.M.

    1996-07-01

    Actinides contamination of soils around Rocky Flats, CO, resulted from leaking drums of Pu-contaminated oil stored at an outdoor site. The transport of these actinides through the soil to groundwater was studied using an advanced monitoring system (MS). The fully automated, remotely controlled MS gathered real-time data on soil water content, groundwater level, and timing of gravitationally flowing water. Controlled rain simulations coupled with measurements of volume flux and actinide activities provided essential information about the fate and transport of Pu-239 + 240 and Am-241. Volume fluxes at most sampling locations were similar, regardless of the antecedent moisture or themore » duration, frequency, and intensity of the simulated rain. Actinide activities were not correlated with the measured volume flux, or the duration, frequency, and intensity of the simulated rain. Flow was facilitated primarily via macropore channeling. The relatively short residence time precluded a continuous interaction between the soil and the flowing water, which minimized the movement of actinides in the soil. Actinide activities in the interstitial water collected from the upper 20 cm of the soil were significantly higher (P>0.001) than water collected at deeper sampling depths (20-70 cm). Actinide activity in water samples from the deepest sampling depth (40-70 cm) did not exceed 0.4 Bq/L. These results suggest that, under the experimental conditions, the movement of actinides was restricted to the top 20 cm. A transport mechanism involving discrete Pu oxide particles, coupled with macropore channeling is proposed to explain the observed actinide activities in the soil. 31 refs., 6 figs., 7 tabs.« less

  1. Isolation of pathogenic Naegleria from artificially heated waters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R L; Willaert, E; Stevens, A R

    1977-01-01

    Investigations were undertaken to determine whether heated waters facilitate the proliferation of free-living amoeba that cause primary amoebic meningoencephalitis. Water samples were taken close to the discharges of power plants situated on lakes or rivers in Florida and Texas and from cooling towers in Tennessee. The water temperatures ranged from 29 to 42/sup 0/C. Water samples were also taken from several lakes in Florida and Texas without associated power plants. The water temperatures of these ranged from 30/sup 0/ to 34/sup 0/C. Twenty-five-250-ml samples were filtered through membranes. Samples taken from the control lakes and cooling towers showed no growthmore » of pathogenic amoeba, whereas growth was obtained from 2 of the 8 lakes and rivers in Florida and from 1 of the 7 man-made lakes in Texas that were artificially heated. The amoebae were identified as belonging to the genus Naegleria from their trophozoite and cyst structure, ability to grow at 45/sup 0/C, to transform into flagellates, and to produce primary amebic meningoencephalitis (PAME) in mice after intranasal instillation. Their identification as N. fowleri was confirmed by indirect immunofluorescent analysis with antiserum produced against N. fowleri. These findings indicate that artificial heating of waters may facilitate the growth of pathogenic free living amoeba.« less

  2. Methods for collecting benthic invertebrate samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic invertebrate communities are evaluated as part of the ecological survey component of the U.S. Geological Survey's National Water-Quality Assessment Program. These biological data are collected along with physical and chemical data to assess water-quality conditions and to develop an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. The objectives of benthic invertebrate community characterizations are to (1) develop for each site a list of tax a within the associated stream reach and (2) determine the structure of benthic invertebrate communities within selected habitats of that reach. A nationally consistent approach is used to achieve these objectives. This approach provides guidance on site, reach, and habitat selection and methods and equipment for qualitative multihabitat sampling and semi-quantitative single habitat sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data within and among study units.

  3. Angiotensinogen concentration in the cerebrospinal fluid in different experimental conditions in the rat.

    PubMed

    Ruiz, P; Basso, N; Grinspon, D; Mangiarua, E; Cannata, M A

    1983-01-01

    Angiotensinogen is the most important component of the renin-angiotensin system present in the cerebrospinal fluid (CSF) of the rat. Its physiological significance as well as its origin have not been clearly elucidated. In this experiment we have examined plasma renin activity (PRA) and plasma and CSF angiotensinogen concentration under the following experimental conditions in male rats of the Wistar strain: 1) adrenalectomy (Adx) 4 days prior to sample collection; controls were sham Adx animals; 2) nephrectomy (Nx) 48 hours before blood and CSF collection; controls were sham Nx rats; 3) DOC-salt treatment (Cortexon depot, 50 mg/kg.s.c. twice a week) plus saline to drink was given during 4 weeks; controls were intact rats; 4) DOC-salt plus captopril: captopril (100 mg/kg/day) in the drinking fluid was added to the treatment of experimental and control animals of Group 3; 5) two-kidney, two clip hypertension: silver clips placed in both renal arteries 8 weeks before samples collection; control: sham-operated rats; 6) water deprivation: rats deprived of water for 5 days; controls: intact rats; 7) peripheral sympathectomy: 6-hydroxydopamine (6-HODA) injected s.c. from birth until 16 weeks of age, adrenodemedullectomy and adrenal denervation performed at 8 weeks; controls were vehicle-injected animals. Determination of angiotensinogen concentration in plasma and CSF was accomplished by incubation of the samples with excess hog renin. The angiotensin I released as well as PRA were evaluated using an specific radioimmunoassay technique. PRA was significantly increased by Adx, captopril treatment, and water deprivation, and was almost suppressed by Nx, DOC-salt, and DOC-salt plus captopril treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Trend of Legionella colonization in hospital water supply.

    PubMed

    D'Alessandro, D; Fabiani, M; Cerquetani, F; Orsi, G B

    2015-01-01

    In many nosocomial Legionella outbreaks water distribution systems are the most frequent source of infection. Considering the hospital waterline old age, an investigation on colonization by Legionella spp was carried out in order to evaluate the pipeline system weaknesses and to implement environmental preventive measures. From 2004 to 2010, overall 97 samples from the water line were collected. The samples were analyzed according to the italian Legionella spp standard methods; water temperature, pH and residual free chlorine were determined at the time of collection. X2 test, exact-test and t-test were used to compare proportions and means. Overall 28 samples (23.7%) were positive for Legionella spp, and five of them (17.9%) exceeded the threshold level >104 cfu/L. The number of positive samples varied along the years, showing a significant increasing trend (X2 for trend = 11.5; p<0.01), but most occurred in 2008 (53,6%), when the hospital underwent major building reconstruction. Samples positive for Legionella spp by comparison to negative ones showed a lower free chlorine concentration (0.08 mg/L vs 0.15 mg/L) and a higher water temperature (46.1° vs 42.7°). Actually the percentage of positive samples decreased significantly with the increasing in free chlorine in the water (X2 for trend = 8.53; p<0.01). The samples collected at the connection between public water line with the hospital supply network were always free from Legionella. All hospital buildings were colonized by Legionella spp, although 80% of samples >104 cfu/L occurred in the C-building. No cases of nosocomial legionellosis were reported during the study period. Hospital water system showed a diffuse colonization by Legionella spp, although the degree of contamination reached the threshold level (>104 cfu/L) only in a small percentage of samples, showing a substantial effectiveness of the control measures applied.

  5. Forecast model for a water table control system in cranberry production

    NASA Astrophysics Data System (ADS)

    Racine, Cintia; José Gumiere, Silvio; Paniconi, Claudio; Dupuis, Christian; Lafond, Jonathan; Scudeler, Carlotta; Camporese, Matteo

    2017-04-01

    Water table control is gaining popularity in cranberry production. Cranberry plants require specific soil moisture conditions to enhance crop yields. In fact, water table control systems installed in the fields allow the plants to respond efficiently to the daily demand for evapotranspiration by capillarity rise and also regulate the soil water excess in drainage conditions. The scope of this study is to develop a forecast hydrological model at the field scale, able to simulate water level for water table control operations. In this work, the finite element CATHY (CATchment Hydrology) model associated with sequential data assimilation with an ensemble Kalman filter (EnKF) method will be used to simulated the soil water dynamics and perform model calibration in real-time. The study is conducted in cranberry fields located in Québec, Canada. During the last five years, these fields were extensive characterized regarding hydrological, pedological, and geological processes. Data collected from LIDAR and Ground Penetrating Radar (GPR) surveys and in-situ soil sampling have been used to define the domain geometry and initial soil properties. First results are promising and in agreement the in-situ water table measurements.

  6. Factors controlling the regional distribution of vanadium in ground water

    USGS Publications Warehouse

    Wright, Michael T.; Belitz, Kenneth

    2010-01-01

    Although the ingestion of vanadium (V) in drinking water may have possible adverse health effects, there have been relatively few studies of V in groundwater. Given the importance of groundwater as a source of drinking water in many areas of the world, this study examines the potential sources and geochemical processes that control the distribution of V in groundwater on a regional scale. Potential sources of V to groundwater include dissolution of V rich rocks, and waste streams from industrial processes. Geochemical processes such as adsorption/desorption, precipitation/dissolution, and chemical transformations control V concentrations in groundwater. Based on thermodynamic data and laboratory studies, V concentrations are expected to be highest in samples collected from oxic and alkaline groundwater. However, the extent to which thermodynamic data and laboratory results apply to the actual distribution of V in groundwater is not well understood. More than 8400 groundwater samples collected in California were used in this study. Of these samples, high (> or = 50 μg/L) and moderate (25 to 49 μg/L) V concentrations were most frequently detected in regions where both source rock and favorable geochemical conditions occurred. The distribution of V concentrations in groundwater samples suggests that significant sources of V are mafic and andesitic rock. Anthropogenic activities do not appear to be a significant contributor of V to groundwater in this study. High V concentrations in groundwater samples analyzed in this study were almost always associated with oxic and alkaline groundwater conditions, which is consistent with predictions based on thermodynamic data.

  7. [The design and experiment of multi-parameter water quality monitoring microsystem based on MOEMS microspectrometer].

    PubMed

    Wei, Kang-Lin; Wen, Zhi-Yu; Guo, Jian; Chen, Song-Bo

    2012-07-01

    Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.

  8. METHOD 544. DETERMINATION OF MICROCYSTINS AND ...

    EPA Pesticide Factsheets

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensitivity and ability to speciate the microcystins. This method development task establishes sample preservation techniques, sample concentration and analytical procedures, aqueous and extract holding time criteria and quality control procedures. Draft Method 544 undergone a multi-laboratory verification to ensure other laboratories can implement the method and achieve the quality control measures specified in the method. It is anticipated that Method 544 may be used in UCMR 4 to collect nationwide occurrence data for selected microcystins in drinking water. The purpose of this research project is to develop an accurate and precise analytical method to concentrate and determine selected MCs and nodularin in drinking water.

  9. Water- and air-quality monitoring of the Sweetwater Reservoir Watershed, San Diego County, California - Phase One results, continued, 2001-2003

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.

    2008-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.

  10. Interpreting and Reporting Radiological Water-Quality Data

    USGS Publications Warehouse

    McCurdy, David E.; Garbarino, John R.; Mullin, Ann H.

    2008-01-01

    This document provides information to U.S. Geological Survey (USGS) Water Science Centers on interpreting and reporting radiological results for samples of environmental matrices, most notably water. The information provided is intended to be broadly useful throughout the United States, but it is recommended that scientists who work at sites containing radioactive hazardous wastes need to consult additional sources for more detailed information. The document is largely based on recognized national standards and guidance documents for radioanalytical sample processing, most notably the Multi-Agency Radiological Laboratory Analytical Protocols Manual (MARLAP), and on documents published by the U.S. Environmental Protection Agency and the American National Standards Institute. It does not include discussion of standard USGS practices including field quality-control sample analysis, interpretive report policies, and related issues, all of which shall always be included in any effort by the Water Science Centers. The use of 'shall' in this report signifies a policy requirement of the USGS Office of Water Quality.

  11. Distribution of butyltins in the waters and sediments along the coast of India.

    PubMed

    Garg, Anita; Meena, Ram M; Jadhav, Sangeeta; Bhosle, Narayan B

    2011-02-01

    Water and surface sediment samples were analyzed for butyltins (TBT, DBT, MBT) from various ports along the east and west coast of India. The total butyltin (TB) in water samples varied between ~1.7 and 342 ng S nl⁻¹, whereas for sediments it varied between below detection limit to 14861 ng S ng⁻¹ dry weight of sediment. On an average Chennai port recorded the highest level of butyltins in the sediments while Paradip recorded the highest level of butylins in the waters. A fairly good relationship between the TB in the sediment and overlying water samples, as well as between organic carbon and TB, implicates the importance of adsorption/desorption process in controlling the levels of TBT in these port areas. In India the data on organotin pollution is very sparse; most of the port areas have been surveyed for butyltins for the first time during this study. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Detection of Legionella, L. pneumophila and Mycobacterium Avium Complex (MAC) along Potable Water Distribution Pipelines

    PubMed Central

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-01-01

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use. PMID:25046636

  13. Detection of Legionella, L. pneumophila and Mycobacterium avium complex (MAC) along potable water distribution pipelines.

    PubMed

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-07-18

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.

  14. Resource-limited heterotrophic prokaryote production and its potential environmental impact associated with Mn nodule exploitation in the northeast equatorial pacific.

    PubMed

    Hyun, Jung-Ho

    2006-08-01

    Shipboard enrichment incubation experiments were performed to elucidate the limiting resources for heterotrophic prokaryotic production and to discuss the potential impact of bottom water and sediment discharges in relation to manganese (Mn) nodule exploitation on the heterotrophic prokaryotes in the oligotrophic northeast equatorial Pacific. Compared to an unamended control, the production of heterotrophic prokaryotes increased 25-fold in water samples supplemented with amino acids (i.e., organic carbon plus nitrogen), whereas the production increased five and two times, respectively, in samples supplemented with either glucose or ammonium alone. These results indicate that heterotrophic prokaryote production in the northeast equatorial Pacific was co-limited by the availability of dissolved organic carbon and inorganic nitrogen. In samples from the nutrient-depleted surface mixed layer (10-m depth), the addition of a slurry of bottom water and sediment doubled heterotrophic prokaryote production compared to an unamended control, whereas sonicating the slurry prior to addition quadrupled the production rate. However, little difference was observed between an unamended control and slurry-amended samples in the subsurface chlorophyll a (Chl a) maximum (SCM) layer. Thus, the impact of slurry discharge is more significant at the nutrient-depleted surface mixed layer than at the high-nutrient SCM layer. The greatly enhanced prokaryote production resulting from the addition of sonicated slurry further suggests that dissociated organic carbon may directly stimulate heterotrophic prokaryote production in the surface mixed layer. Overall, the results suggest that the surface discharge of bottom water and sediments during manganese nodule exploitation could have a significant environmental impact on the production of heterotrophic prokaryotes that are currently resource limited.

  15. Assessment of Drinking Water Quality from Bottled Water Coolers

    PubMed Central

    FARHADKHANI, Marzieh; NIKAEEN, Mahnaz; AKBARI ADERGANI, Behrouz; HATAMZADEH, Maryam; NABAVI, Bibi Fatemeh; HASSANZADEH, Akbar

    2014-01-01

    Abstract Background Drinking water quality can be deteriorated by microbial and toxic chemicals during transport, storage and handling before using by the consumer. This study was conducted to evaluate the microbial and physicochemical quality of drinking water from bottled water coolers. Methods A total of 64 water samples, over a 5-month period in 2012-2013, were collected from free standing bottled water coolers and water taps in Isfahan. Water samples were analyzed for heterotrophic plate count (HPC), temperature, pH, residual chlorine, turbidity, electrical conductivity (EC) and total organic carbon (TOC). Identification of predominant bacteria was also performed by sequence analysis of 16S rDNA. Results The mean HPC of water coolers was determined at 38864 CFU/ml which exceeded the acceptable level for drinking water in 62% of analyzed samples. The HPC from the water coolers was also found to be significantly (P < 0.05) higher than that of the tap waters. The statistical analysis showed no significant difference between the values of pH, EC, turbidity and TOC in water coolers and tap waters. According to sequence analysis eleven species of bacteria were identified. Conclusion A high HPC is indicative of microbial water quality deterioration in water coolers. The presence of some opportunistic pathogens in water coolers, furthermore, is a concern from a public health point of view. The results highlight the importance of a periodic disinfection procedure and monitoring system for water coolers in order to keep the level of microbial contamination under control. PMID:26060769

  16. Quality of nutrient data from streams and ground water sampled during water years 1992-2001

    USGS Publications Warehouse

    Mueller, David K.; Titus, Cindy J.

    2005-01-01

    Proper interpretation of water-quality data requires consideration of the effects that bias and variability might have on measured constituent concentrations. In this report, methods are described to estimate the bias due to contamination of samples in the field or laboratory and the variability due to sample collection, processing, shipment, and analysis. Contamination can adversely affect interpretation of measured concentrations in comparison to standards or criteria. Variability can affect interpretation of small differences between individual measurements or mean concentrations. Contamination and variability are determined for nutrient data from quality-control samples (field blanks and replicates) collected as part of the National Water-Quality Assessment (NAWQA) Program during water years 1992-2001. Statistical methods are used to estimate the likelihood of contamination and variability in all samples. Results are presented for five nutrient analytes from stream samples and four nutrient analytes from ground-water samples. Ammonia contamination can add at least 0.04 milligram per liter in up to 5 percent of all samples. This could account for more than 22 percent of measured concentrations at the low range of aquatic-life criteria (0.18 milligram per liter). Orthophosphate contamination, at least 0.019 milligram per liter in up to 5 percent of all samples, could account for more than 38 percent of measured concentrations at the limit to avoid eutrophication (0.05 milligram per liter). Nitrite-plus-nitrate and Kjeldahl nitrogen contamination is less than 0.4 milligram per liter in 99 percent of all samples; thus there is no significant effect on measured concentrations of environmental significance. Sampling variability has little or no effect on reported concentrations of ammonia, nitrite-plus-nitrate, orthophosphate, or total phosphorus sampled after 1998. The potential errors due to sampling variability are greater for the Kjeldahl nitrogen analytes and for total phosphorus sampled before 1999. The uncertainty in a mean of 10 concentrations caused by sampling variability is within a small range (1 to 7 percent) for all nutrients. These results can be applied to interpretation of environmental data collected during water years 1992-2001 in 52 NAWQA study units.

  17. Water quality assessment in terms of water quality index (WQI): case study of the Kolong River, Assam, India

    NASA Astrophysics Data System (ADS)

    Bora, Minakshi; Goswami, Dulal C.

    2017-10-01

    The Kolong River of Nagaon district, Assam has been facing serious degradation leading to its current moribund condition due to a drastic human intervention in the form of an embankment put across it near its take-off point from the Brahmaputra River in the year 1964. The blockage of the river flow was adopted as a flood control measure to protect its riparian areas, especially the Nagaon town, from flood hazard. The river, once a blooming distributary of the mighty Brahmaputra, had high navigability and rich riparian biodiversity with a well established agriculturally productive watershed. However, the present status of Kolong River is highly wretched as a consequence of the post-dam effects thus leaving it as stagnant pools of polluted water with negligible socio-economic and ecological value. The Central Pollution Control Board, in one of its report has placed the Kolong River among 275 most polluted rivers of India. Thus, this study is conducted to analyze the seasonal water quality status of the Kolong River in terms of water quality index (WQI). The WQI scores shows very poor to unsuitable quality of water samples in almost all the seven sampling sites along the Kolong River. The water quality is found to be most deteriorated during monsoon season with an average WQI value of 122.47 as compared to pre-monsoon and post-monsoon season having average WQI value of 85.73 and 80.75, respectively. Out of the seven sampling sites, Hatimura site (S1) and Nagaon Town site (S4) are observed to be the most polluted sites.

  18. BOD and DO Identification of Jeneberrang-River Water as Water Source

    NASA Astrophysics Data System (ADS)

    Basir, Basir; Haris, Ibrahim Abdul

    2018-05-01

    Water is a part of life on the surface of the earth. It is not a new substance which no life on earth can survive without water. This study aims to identify the quality of river water of jeneberang as municipal waterworks (PDAM) raw regarding to turbidity parameters, BOD, and DO. The used methodology is observational with descriptive approach. The sampling technique was done by grasping each sample for turbidity parameter, BOD and DO in four IPAM water inlet of Makassar City. This sampling was conducted at Laboratory of Environmental Health Engineering Center (BTKL) and Disease Control using Nephelometric Turbidity Unit, Titrimetry, and Spectrophotometric method. The results of the examination showed that the turbidity level> 5 NTU, so it is not eligible to be drunk directly. The levels for BOD and eligibles for not exceeding the specified limits are <3 mg / l and <25 mg / l and in DO for Maccini Sombala <4 mg / l region, so it is not eligible. The conclusion in this research that turbidity parameter, BOD and DO qualify as the raw water of PDAM have to be processed so that water can be drunk by society.

  19. Effects of Shampoo and Water Washing on Hair Cortisol Concentrations

    PubMed Central

    Hamel, Amanda F.; Meyer, Jerrold S.; Henchey, Elizabeth; Dettmer, Amanda M.; Suomi, Stephen J.; Novak, Melinda A.

    2010-01-01

    Background Measurement of cortisol in hair is an emerging biomarker for chronic stress in human and nonhuman primates. Currently unknown, however, is the extent of potential cortisol loss from hair that has been repeatedly exposed to shampoo and/or water. Methods Pooled hair samples from 20 rhesus monkeys were subjected to five treatment conditions: 10, 20, or 30 shampoo washes, 20 water-only washes, or a no-wash control. For each wash, hair was exposed to a dilute shampoo solution or tap water for 45 s, rinsed 4 times with tap water, and rapidly dried. Samples were then processed for cortisol extraction and analysis using previously published methods. Results Hair cortisol levels were significantly reduced by washing, with an inverse relationship between number of shampoo washes and the cortisol concentration. This effect was mainly due to water exposure, as cortisol levels following 20 water-only washes were similar to those following 20 shampoo treatments. Conclusions Repeated exposure to water with or without shampoo appears to leach cortisol from hair, yielding values that underestimate the amount of chronic hormone deposition within the shaft. Collecting samples proximal to the scalp and obtaining hair washing frequency data may be valuable when conducting human hair cortisol studies. PMID:21034727

  20. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2005 to June 30, 2006

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.; Young-Smith, Stacie T. M.

    2006-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous discharge data at one station, continuous streamflow data at two stations, and water-quality data at five stations, which include the continuous discharge and streamflow stations. This report summarizes rainfall, discharge, streamflow, and water-quality data collected between July 1, 2005 and June 30, 2006. A total of 23 samples was collected over five storms during July 1, 2005 to June 30, 2006. The goal was to collect grab samples nearly simultaneously at all five stations, and flow-weighted time-composite samples at the three stations equipped with automatic samplers; however, all five storms were partially sampled owing to lack of flow at the time of sampling at some sites, or because some samples collected by the automatic sampler did not represent water from the storm. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  1. Detection of enteroviruses in untreated and treated drinking water supplies in South Africa.

    PubMed

    Ehlers, M M; Grabow, W O K; Pavlov, D N

    2005-06-01

    Enteric viruses have been detected in many drinking water supplies all over the world. A meaningful number of these supplies were treated and disinfected according to internationally acceptable methods. In addition, counts of bacterial indicators (coliform bacteria and heterotrophic plate count organisms) in these water supplies were within limits generally recommended for treated drinking water and these findings have been supported by epidemiological data on infections associated with drinking water. The shortcomings of conventional treatment methods and indicator organisms to confirm the absence of enteric viruses from drinking water, was generally ascribed to the exceptional resistance of these viruses. In this study, the prevalence of enteroviruses detected from July 2000 to June 2002 in sewage, river-, borehole-, spring- and dam water as well as drinking water supplies treated and disinfected according to international specifications for the production of safe drinking water was analysed. A glass wool adsorption-elution technique was used to recover viruses from 10--20 l of sewage as well as environmental water samples, in the case of drinking water from more than 100 l. Recovered enteroviruses were inoculated onto two cell culture types (BGM and PLC/PRF/5 cells) for amplification of viral RNA with nested-PCR being used to detect the amplified viral RNA. Results from the study demonstrated the presence of enteroviruses in 42.5% of sewage and in 18.7% of treated drinking water samples. Furthermore, enteroviruses were detected in 28.5% of river water, in 26.7% of dam/spring water and in 25.3% of borehole water samples. The high prevalence of coxsackie B viruses found in this study suggested, that a potential health risk and a burden of disease constituted by these viruses might be meaningful. These findings indicated that strategies, other than end-point analysis of treated and disinfected drinking water supplies, may be required to ensure the production of drinking water that does not exceed acceptable health risks. More reliable approaches to ensure acceptable safety of drinking water supplies may be based on control by multiple-barrier principles from catchment to tap using hazard assessment and critical control point (HACCP) principles.

  2. Cryptosporidium Oocyst Detection in Water Samples: Floatation Technique Enhanced with Immunofluorescence Is as Effective as Immunomagnetic Separation Method

    PubMed Central

    Koompapong, Khuanchai; Sutthikornchai, Chantira

    2009-01-01

    Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, 101, 102, and 103 per 10 µl were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < 102 per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting. PMID:19967082

  3. Cryptosporidium oocyst detection in water samples: floatation technique enhanced with immunofluorescence is as effective as immunomagnetic separation method.

    PubMed

    Koompapong, Khuanchai; Sutthikornchai, Chantira; Sukthana, Yowalark

    2009-12-01

    Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, 10(1), 10(2), and 10(3) per 10 microl were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < 10(2) per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting.

  4. Total N-nitrosamine Precursor Adsorption with Carbon Nanotubes: Elucidating Controlling Physiochemical Properties and Developing a Size-Resolved Precursor Surrogate

    NASA Astrophysics Data System (ADS)

    Needham, Erin Michelle

    As drinking water sources become increasingly impaired with nutrients and wastewater treatment plant (WWTP) effluent, formation of disinfection byproducts (DBPs)--such as trihalomethanes (THMs), dihaloacetonitriles (DHANs), and N-nitrosamines--during water treatment may also increase. N-nitrosamines may comprise the bulk of the chronic toxicity in treated drinking waters despite forming at low ng/L levels. This research seeks to elucidate physicochemical properties of carbon nanotubes (CNTs) for removal of DBP precursors, with an emphasis on total N-nitrosamines (TONO). Batch experiments with CNTs were completed to assess adsorption of THM, DHAN, and TONO precursors; physiochemical properties of CNTs were quantified through gas adsorption isotherms and x-ray photoelectron spectroscopy. Numerical modeling was used to elucidate characteristics of CNTs controlling DBP precursor adsorption. Multivariate models developed with unmodified CNTs revealed that surface carboxyl groups and, for TONO precursors, cumulative pore volume (CPV), controlled DBP precursor adsorption. Models developed with modified CNTs revealed that specific surface area controlled adsorption of THM and DHAN precursors while CPV and surface oxygen content were significant for adsorption of TONO precursors. While surrogates of THM and DHAN precursors leverage metrics from UV absorbance and fluorescence spectroscopy, a TONO precursor surrogate has proved elusive. This is important as measurements of TONO formation potential (TONOFP) require large sample volumes and long processing times, which impairs development of treatment processes. TONO precursor surrogates were developed using samples that had undergone oxidative or sorption treatments. Precursors were analyzed with asymmetric flow field-flow fractionation (AF4) with inline fluorescence detection (FLD) and whole water fluorescence excitation-emission matrices (EEMs). TONO precursor surrogates were discovered, capable of predicting changes in TONOFP in WWTP samples that have undergone oxidation (R2 = 0.996) and sorption (R2 = 0.576). Importantly, both surrogates only require just 2 mL of sample volume to measure and take only 1 hour. Application of the sorption precursor surrogate revealed that DBP precursor adsorption was feasible with freeform CNT microstructures with various dimensions and surface chemistries, establishing a framework for development of this novel CNT application for drinking water treatment.

  5. PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology

    USGS Publications Warehouse

    Kellogg, Christina A.; Piceno, Yvette M.; Tom, Lauren M.; DeSantis, Todd Z.; Zawada, David G.; Andersen, Gary L.

    2012-01-01

    Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease.

  6. PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology.

    PubMed

    Kellogg, Christina A; Piceno, Yvette M; Tom, Lauren M; DeSantis, Todd Z; Zawada, David G; Andersen, Gary L

    2012-01-01

    Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease. Published by Elsevier B.V.

  7. A Year in the Life of a Contaminated Heater-Cooler Unit With Mycobacterium chimaera?

    PubMed

    Garvey, Mark I; Bradley, Craig W; Walker, Jimmy

    2017-06-01

    OBJECTIVE Heater-cooler units (HCUs) have been shown to be a source of Mycobacterium chimaera infections. For the past year, weekly water samples have been taken from HCUs used at University Hospitals Birmingham (UHB) NHS Foundation Trust. We report the microbial contamination of the HCUs over a year detailing the decontamination regimes applied at UHB to reduce the microbial load. DESIGN Observational study SETTING UHB is a tertiary referral teaching hospital in Birmingham, United Kingdom, that provides clinical services to nearly 1 million patients every year. The UHB Cardiac department is one of the largest in the United Kingdom and provides treatment for adult patients with a wide range of cardiac diseases. METHODS Water samples taken from HCUs used at UHB for cardiopulmonary bypass surgery were sampled over a year to determine the number of microorganisms by membrane filtration. Various decontamination processes were employed throughout the year. RESULTS Varying total viable counts containing a wide variety of microorganisms were obtained from water inside the HCUs. No M. chimaera were isolated after replacement of the HCU internal tubing. Stringent decontamination regimes resulted in degradation of the HCUs and increased TVCs after several months. CONCLUSION More work is required to ensure effective decontamination processes to reduce the microbial load within the HCUs. Our studies indicate that weekly water sampling for TVC will be required indefinitely to monitor the water quality in these units as well as regular replacement of the tubing to control the build-up of biofilm. Infect Control Hosp Epidemiol 2017;38:705-711.

  8. Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions

    USGS Publications Warehouse

    Charlestra, Lucner; Amirbahman, Aria; Courtemanch, David L.; Alvarez, David A.; Patterson, Howard

    2012-01-01

    The polar organic chemical integrative sampler (POCIS) was calibrated to monitor pesticides in water under controlled laboratory conditions. The effect of natural organic matter (NOM) on the sampling rates (Rs) was evaluated in microcosms containing -1 of total organic carbon (TOC). The effect of hydrodynamics was studied by comparing Rs values measured in stirred (SBE) and quiescent (QBE) batch experiments and a flow-through system (FTS). The level of NOM in the water used in these experiments had no effect on the magnitude of the pesticide sampling rates (p > 0.05). However, flow velocity and turbulence significantly increased the sampling rates of the pesticides in the FTS and SBE compared to the QBE (p < 0.001). The calibration data generated can be used to derive pesticide concentrations in water from POCIS deployed in stagnant and turbulent environmental systems without correction for NOM.

  9. NEW TARGET AND CONTROL ASSAYS FOR QUANTITATIVE POLYMERASE CHAIN REACTION (QPCR) ANALYSIS OF ENTEROCOCCI IN WATER

    EPA Science Inventory

    Enterococci are frequently monitored in water samples as indicators of fecal pollution. Attention is now shifting from culture based methods for enumerating these organisms to more rapid molecular methods such as QPCR. Accurate quantitative analyses by this method requires highly...

  10. Evaluation of Nonpoint-Source Contamination, Wisconsin: Selected Topics for Water Year 1995

    USGS Publications Warehouse

    Owens, D.W.; Corsi, Steven R.; Rappold, K.F.

    1997-01-01

    The objective of the watershed-management evaluation monitoring program in Wisconsin is to evaluate the effectiveness of best-management practices (BMP's) for controlling nonpoint-source contamination in eight rural and four urban watersheds. This report, the fourth in an annual series of reports, presents a summary of the data collected for the program by the U.S. Geological Survey and the results of several detailed analyses of the data. To complement assessments of water quality, a land-use and BMP inventory is ongoing for 12 evaluation monitoring projects to track nonpoint sources of contamination in each watershed and to document implementation of BMP's that were designed to cause changes in the water quality of streams. Each year, updated information is gathered, mapped, and stored in a geographic-information-system data base. Summaries of land-use, BMP implementation, and water-quality data collected during water years 1989-95 are presented. Storm loads, snowmelt-period loads, and annual loads of suspended sediment and total phosphorus are summarized for eight rural sites. Storm-load data for suspended solids, total phosphorus, total recoverable lead, copper, zinc, and cadmium are summarized for four urban sites. Quality-assurance and quality-control (QA/QC) samples were collected at the eight rural sites to evaluate inorganic sample contamination and at one urban site to evaluate sample-collection and filtration techniques for polycyclic aromatic hydrocarbons (PAR's). Some suspended solids and fecal coliform contamination was detected at the rural sites. Corrective actions will be taken to address this contamination. Evaluation of PAR sample-collection techniques did not uncover any deficiencies, but the small amount of data collected was not sufficient to draw any definite conclusions. Evaluation of PAR filtration techniques indicate that water-sample filtration with O.7-um glass-fiber filters in an aluminum filter unit does not result in significant loss of PAR.

  11. Geochemical evolution processes and water-quality observations based on results of the National Water-Quality Assessment Program in the San Antonio segment of the Edwards aquifer, 1996-2006

    USGS Publications Warehouse

    Musgrove, MaryLynn; Fahlquist, Lynne; Houston, Natalie A.; Lindgren, Richard J.; Ging, Patricia B.

    2010-01-01

    As part of the National Water-Quality Assessment Program, the U.S. Geological Survey collected and analyzed groundwater samples during 1996-2006 from the San Antonio segment of the Edwards aquifer of central Texas, a productive karst aquifer developed in Cretaceous-age carbonate rocks. These National Water-Quality Assessment Program studies provide an extensive dataset of groundwater geochemistry and water quality, consisting of 249 groundwater samples collected from 136 sites (wells and springs), including (1) wells completed in the shallow, unconfined, and urbanized part of the aquifer in the vicinity of San Antonio (shallow/urban unconfined category), (2) wells completed in the unconfined (outcrop area) part of the regional aquifer (unconfined category), and (3) wells completed in and springs discharging from the confined part of the regional aquifer (confined category). This report evaluates these data to assess geochemical evolution processes, including local- and regional-scale processes controlling groundwater geochemistry, and to make water-quality observations pertaining to sources and distribution of natural constituents and anthropogenic contaminants, the relation between geochemistry and hydrologic conditions, and groundwater age tracers and travel time. Implications for monitoring water-quality trends in karst are also discussed. Geochemical and isotopic data are useful tracers of recharge, groundwater flow, fluid mixing, and water-rock interaction processes that affect water quality. Sources of dissolved constituents to Edwards aquifer groundwater include dissolution of and geochemical interaction with overlying soils and calcite and dolomite minerals that compose the aquifer. Geochemical tracers such as magnesium to calcium and strontium to calcium ratios and strontium isotope compositions are used to evaluate and constrain progressive fluid-evolution processes. Molar ratios of magnesium to calcium and strontium to calcium in groundwater typically increase along flow paths; results for samples of Edwards aquifer groundwater show an increase from shallow/urban unconfined, to unconfined, to confined groundwater categories. These differences are consistent with longer residence times and greater extents of water-rock interaction controlling fluid compositions as groundwater evolves from shallow unconfined groundwater to deeper confined groundwater. Results for stable isotopes of hydrogen and oxygen indicate specific geochemical processes affect some groundwater samples, including mixing with downdip saline water, mixing with recent recharge associated with tropical cyclonic storms, or mixing with recharge water than has undergone evaporation. The composition of surface water recharging the aquifer, as well as mixing with downdip water from the Trinity aquifer or the saline zone, also might affect water quality. A time-series record (1938-2006) of discharge at Comal Springs, one of the major aquifer discharge points, indicates an upward trend for nitrate and chloride concentrations, which likely reflects anthropogenic activities. A small number of organic contaminants were routinely or frequently detected in Edwards aquifer groundwater samples. These were the pesticides atrazine, its degradate deethylatrazine, and simazine; the drinking-water disinfection byproduct chloroform; and the solvent tetrachloroethene. Detection of these contaminants was most frequent in samples of the shallow/urban unconfined groundwater category and least frequent in samples of the unconfined groundwater category. Results indicate that the shallow/urban unconfined part of the aquifer is most affected by anthropogenic contaminants and the unconfined part of the aquifer is the least affected. The high frequency of detection for these anthropogenic contaminants aquifer-wide and in samples of deep, confined groundwater indicates that the entire aquifer is susceptible to water-quality changes as a result of anthropogenic activities. L

  12. Disinfection of Contaminated Water by Using Solar Irradiation

    PubMed Central

    Caslake, Laurie F.; Connolly, Daniel J.; Menon, Vilas; Duncanson, Catriona M.; Rojas, Ricardo; Tavakoli, Javad

    2004-01-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min. PMID:14766599

  13. The impact of the High Park Wildfire on stream water quality and implications for drinking water treatment

    NASA Astrophysics Data System (ADS)

    Rosario-Ortiz, F.

    2014-12-01

    The Cache La Poudre (CLP) watershed in Northern Colorado was impacted by the High Park fire, which burned from June 9th through July 1st of 2012. The CLP watershed serves as a source of drinking water for three water districts in Northern Colorado, including the City of Fort Collins. Sampling was conducted during four different storm events immediately after the fire was extinguished. The sampling was expanded through spring and summer 2013 in order to capture the flush of debris from the wildfire into the CLP River. Samples were also collected from an unburned control site for comparison. Surface water samples were analyzed for parameters including nutrients, dissolved organic carbon (DOC) concentration and dissolved organic matter (DOM) characterization. In addition, bench scale treatment analyses were conducted to better understand the impacts of the wildfire on treatment processes for drinking water utilities. Lastly, leaching of stream bank sediments was conducted to determine the potential longer term inputs of burned material to the stream water. The overarching goals of the sampling campaign were to: 1) Evaluate the impact that wildfires have on the properties of DOM, specifically with respect to DBP formation and speciation (TTHM, HAA5, HAN, NDMA); 2) Establish the condition under which the source water could be effectively treated (using coagulation) to remove DBP precursors; 3) Evaluate the use of fluorescence spectroscopy as a surrogate for the concentration and reactivity of DOM in the CLP watershed; and 4) Assess the quantity and quality of DOM leached from streambed sediments. Preliminary results showed elevated DOC levels during the storm events and at wildfire impacted sites compared to the unburned site following the fire. DBP yields were higher for the four storm events following the fire when compared to yields for the control site located upstream of the burn area, and also when compared to data from a previous DBP study conducted on similar Colorado source waters in 2010. Fluorescence spectroscopy shows promise as a tool for discerning differences in DOM quality between burned and unburned areas of the CLP watershed. Ultimately, the results of this study will offer insight for recovering this watershed as a sustainable water source and will prepare utilities for future wildfires.

  14. Effect and Process Evaluation of a Cluster Randomized Control Trial on Water Intake and Beverage Consumption in Preschoolers from Six European Countries: The ToyBox-Study

    PubMed Central

    Pinket, An-Sofie; Van Lippevelde, Wendy; De Bourdeaudhuij, Ilse; Deforche, Benedicte; Cardon, Greet; Androutsos, Odysseas; Koletzko, Berthold; Moreno, Luis A.; Socha, Piotr; Iotova, Violeta; Manios, Yannis; De Craemer, Marieke

    2016-01-01

    Background Within the ToyBox-study, a kindergarten-based, family-involved intervention was developed to prevent overweight and obesity in European preschoolers, targeting four key behaviours related to early childhood obesity, including water consumption. The present study aimed to examine the effect of the ToyBox-intervention (cluster randomized controlled trial) on water intake and beverage consumption in European preschoolers and to investigate if the intervention effects differed by implementation score of kindergartens and parents/caregivers. Method A sample of 4964 preschoolers (4.7±0.4 years; 51.5% boys) from six European countries (Belgium, Bulgaria, Germany, Greece, Poland, Spain) was included in the data analyses. A standardized protocol was used and parents/caregivers filled in socio-demographic data and a food-frequency questionnaire. To assess intervention effects, multilevel repeated measures analyses were conducted for the total sample and for the six country-specific samples. Based on the process evaluation questionnaire of teachers and parents/caregivers, an implementation score was constructed. To assess differences in water intake and beverage consumption by implementation score in the total sample, multilevel repeated measures analyses were performed. Results Limited intervention effects on water intake from beverages and overall beverage consumption were found. However, important results were found on prepacked fruit juice consumption, with a larger decrease in the intervention group compared to the control group. However, also a decline in plain milk consumption was found. Implementation scores were rather low in both kindergartens and parents/caregivers. Nevertheless, more favorable effects on beverage choices were found in preschoolers whose parents/caregivers and kindergarten teachers had higher implementation scores compared to those with lower implementation scores. Conclusion The ToyBox-intervention can provide the basis for the development of more tailor-made interventions. However, new strategies to improve implementation of interventions should be created. PMID:27064274

  15. Assessing the fate of radioactive nickel in cultivated soil cores.

    PubMed

    Denys, Sébastien; Echevarria, Guillaume; Florentin, Louis; Leclerc, Elisabeth; Morel, Jean-Louis

    2009-10-01

    Parameters regarding fate of (63)Ni in the soil-plant system (soil: solution distribution coefficient, K(d) and soil plant concentration ratio, CR) are mostly determined in controlled pot experiments or from simple models involving a limited set of soil parameters. However, as migration of pollutants in soil is strongly linked to the water migration, variation of soil structure in the field and seasonal variation of evapotranspiration will affect these two parameters. The aim of this work was to explore to what extent the downward transfer of (63)Ni and its uptake by plants from surface-contaminated undisturbed soil cores under cultivation can be explained by isotopic dilution of this radionuclide in the pool of stable Ni of soils. Undisturbed soil cores (50 cm x 50 cm) were sampled from a brown rendzina (Rendzic Leptosol), a colluvial brown soil (Fluvic Cambisol) and an acidic brown soil (Dystric Cambisol) using PVC lysimeter tubes (three lysimeters sampled per soil type). Each core was equipped with a leachate collector. Cores were placed in a greenhouse and maize (DEA, Pioneer) was sown. After 44 days, an irrigation was simulated at the core surfaces to supply 10 000 Bq (63)NiCl(2). Maize was harvested 135 days after (63)Ni input and radioactivity determined in both vegetal and water samples. Effective uptake of (63)Ni by maize was calculated for leaves and kernels. Water drainage and leaching of (63)Ni were monitored over the course of the experiment. Values of K(d) in surface soil samples were calculated from measured parameters of isotopic exchange kinetics. Results confirmed that (63)Ni was strongly retained at the soil surface. Prediction of the (63)Ni downward transfer could not be reliably assessed using the K(d) values, since the soil structure, which controls local water fluxes, also affected both water and Ni transport. In terms of (63)Ni plant uptake, the effective uptake in undisturbed soil cores is controlled by isotope dilution as previously shown at the pot experiment scale.

  16. [Analysis of feedstuff for pigs, sent in from veterinary practices for quality control].

    PubMed

    Wolf, P; Mösseler, A; Kamphues, J

    2011-01-01

    Nutritional disorders and a reduced performance are common reasons to send in feedstuffs for quality control. The following review illustrates the main nutritional-related problems on pig farms and presents possible causal relationships between feed/feeding and health disorders. The analysis results of feedstuff and drinking water samples that were sent to the institute for animal nutrition between 2000 and 2009 were evaluated retrospectively. Certain trends were revealed. Whereas previously fertility disorders gave rise to analysis of food samples, in recent years the grinding intensity of mixed feeds (potential relationship to gastric ulcers) has become of more interest. Mixed feed in meal form (n=143) showed a usual particle size structure, whereas pelleted and crumbled diets exhibited undesirable, higher proportions of fine particles. A contamination with pests was only found in a few feed samples (0.9% of analysed feedstuffs in 2007). With only a few exceptions the feedstuffs were of a satisfactory hygienic quality. With respect to the chemical composition of the mixed feeds, differences between analysed and labelled levels were detected in terms of crude fibre (63.0% of 138 analysed feed samples). More than 50% of the feedstuffs (n=64) showed aberrations in the botanical composition. Samples of drinking water were checked to an increasing extent (n=120 in 2009) probably due to the fact that drinking water is defined by law as a feedstuff and evaluation criteria exist. Elevated levels of iron and aerobe bacteria (in 50% and 30.8% of samples, respectively) were among the most common findings. The spectrum of analyses has been expanded in recent years. In many cases a relationship could be found between clinical symptoms and alterations within the feed or the drinking water.

  17. Streamflow and water-quality data for Lake Purdy and its tributaries, Jefferson and Shelby Counties, Alabama, water years 1987-91

    USGS Publications Warehouse

    Stricklin, V.E.

    1993-01-01

    An investigation was begun in North Carolina in 1988 to: (1) quantify nutrient, sediment, and freshwater loadings in canals that collect drainage from cropland field ditches; (2) determine the effects of tide gates and flashboard risers on these loadings and on receiving-water quality; and (3) characterize the effects of drainage on the salinity regime of a tidal creek. Data were collected in three canals in Hyde County, three canals in Beaufort County, and in Campbell Creek, which receives drainage directly from two of the Beaufort County canals. Water-control structures were placed on two of the six canals near the beginning of the investigation. Following about 2 years of data collection, control structures were placed on the remaining four canals. Hydrologic and water-quality data are presented for each of the study sites for the period of October 1990 through May 1992. Data presented in this report cover the second phase of the investigation after the installation of water-control structures in the six drainage canals. Following a description of the study sites and data-collection methods, data are presented for five of the drainage canals and Campbell Creek. Data collection was discontinued at one of the Beaufort County sites after the first phase of the investigation. The data collected include: (1) daily values of accumulated precipitation; (2) water-level statistics; (3) daily mean values of discharge in the canals; (4) biweekly water-quality measurements and sample analyses; (5) storm-event water-quality measurements and sample analyses; (6) continuous records of specific conductance in the canals; (7) vertical profiles of salinity in Campbell Creek; and (8) daily mean values of salinity at five sites in Campbell Creek.

  18. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    PubMed

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Determination of pesticides in waters by automatic on-line solid-phase extraction-capillary electrophoresis.

    PubMed

    Hinsmann, P; Arce, L; Ríos, A; Valcárcel, M

    2000-01-07

    The separation of seven pesticides by micellar electrokinetic capillary chromatography in spiked water samples is described, allowing the analysis of pesticides mixtures down to a concentration of 50 microg l(-1) in less than 13 min. Calibration, pre-concentration, elution and injection into the sample vial was carried out automatically by a continuous flow system (CFS) coupled to a capillary electrophoresis system via a programmable arm. The whole system was electronically coupled by a micro-processor and completely controlled by a computer. A C18 solid-phase mini-column was used for the pre-concentration, allowing a 12-fold enrichment (as an average value) of the pesticides from fortified water samples. Under the optimal extraction conditions, recoveries between 90 and 114% for most of the pesticides were obtained.

  20. Clastogenecity evaluation of water of Lake Sevan (Armenia) using Tradescantia micronucleus assay.

    PubMed

    Aghajanyan, E A; Avalyan, R E; Simonyan, A E; Atoyants, A L; Gabrielyan, B K; Aroutiounian, R M; Khosrovyan, A

    2018-05-24

    The clastogenic effects of water samples in seven locations of Lake Sevan (Armenia) with the application of Trad-MCN (micronuclei) bioassay using Tradescantia (clone 02) were investigated. A significant increase in the frequency of micronuclei in tetrads of pollen microspores and tetrads with micronuclei exposed to the test samples compared to the control has been revealed. A multivariate analysis indicated linkage between the frequencies of occurrence of micronuclei in the cells and Ni and Co ions. The results were compared with the endpoints of another Tradescantia-based test system (stamen hair mutation test) performed on the same water samples and generation of the plant: occurrences of micronuclei in sporogenic cells coincided with that of non-surviving stamen hair. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2006 to June 30, 2007

    USGS Publications Warehouse

    Young, Stacie T.M.; Jamison, Marcael T.J.

    2007-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at three stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2006 and June 30, 2007. A total of 13 samples was collected over two storms during July 1, 2006 to June 30, 2007. The goal was to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  2. Monitoring the Presence of 13 Active Compounds in Surface Water Collected from Rural Areas in Northwestern Spain

    PubMed Central

    Iglesias, Alejandra; Nebot, Carolina; Vázquez, Beatriz I.; Coronel-Olivares, Claudia; Franco Abuín, Carlos M.; Cepeda, Alberto

    2014-01-01

    Drug residues are considered environmental contaminants, and their occurrence has recently become a matter of concern. Analytical methods and monitoring systems are therefore required to control the continuous input of these drug residues into the environment. This article presents a suitable HPLC-ESI-MS/MS method for the simultaneous extraction, detection and quantification of residues of 13 drugs (antimicrobials, glucocorticosteroids, anti-inflammatories, anti-hypertensives, anti-cancer drugs and triphenylmethane dyes) in surface water. A monitoring study with 549 water samples was carried out in northwestern Spain to detect the presence of drug residues over two sampling periods during 2010, 2011 and 2012. Samples were collected from rural areas with and without farming activity and from urban areas. The 13 analytes were detected, and 18% of the samples collected showed positive results for the presence of at least one analyte. More collection sites were located in rural areas than in urban areas. However, more positive samples with higher concentrations and a larger number of analytes were detected in samples collected from sites located after the discharge of a WWTP. Results indicated that the WWTPs seems to act as a concentration point. Positive samples were also detected at a site located near a drinking water treatment plant. PMID:24837665

  3. Monitoring the presence of 13 active compounds in surface water collected from rural areas in northwestern Spain.

    PubMed

    Iglesias, Alejandra; Nebot, Carolina; Vázquez, Beatriz I; Coronel-Olivares, Claudia; Abuín, Carlos M Franco; Cepeda, Alberto

    2014-05-15

    Drug residues are considered environmental contaminants, and their occurrence has recently become a matter of concern. Analytical methods and monitoring systems are therefore required to control the continuous input of these drug residues into the environment. This article presents a suitable HPLC-ESI-MS/MS method for the simultaneous extraction, detection and quantification of residues of 13 drugs (antimicrobials, glucocorticosteroids, anti-inflammatories, anti-hypertensives, anti-cancer drugs and triphenylmethane dyes) in surface water. A monitoring study with 549 water samples was carried out in northwestern Spain to detect the presence of drug residues over two sampling periods during 2010, 2011 and 2012. Samples were collected from rural areas with and without farming activity and from urban areas. The 13 analytes were detected, and 18% of the samples collected showed positive results for the presence of at least one analyte. More collection sites were located in rural areas than in urban areas. However, more positive samples with higher concentrations and a larger number of analytes were detected in samples collected from sites located after the discharge of a WWTP. Results indicated that the WWTPs seems to act as a concentration point. Positive samples were also detected at a site located near a drinking water treatment plant.

  4. Mixing alters the lytic activity of viruses in the dark ocean.

    PubMed

    Winter, Christian; Köstner, Nicole; Kruspe, Carl-Philip; Urban, Damaris; Muck, Simone; Reinthaler, Thomas; Herndl, Gerhard J

    2018-03-01

    In aquatic habitats, viral lysis of prokaryotic cells lowers the overall efficiency of the microbial loop, by which dissolved organic carbon is transfered to higher trophic levels. Mixing of water masses in the dark ocean occurs on a global scale and may have far reaching consequences for the different prokaryotic and virus communities found in these waters by altering the environmental conditions these communities experience. We hypothesize that mixing of deep ocean water masses enhances the lytic activity of viruses infecting prokaryotes. To address this hypothesis, major deep-sea water masses of the Atlantic Ocean such as North Atlantic Deep Water, Mediterranean Sea Overflow Water, Antarctic Intermediate Water, and Antarctic Bottom Water were sampled at five locations. Prokaryotic cells from these samples were collected by filtration and subsequently incubated in virus-reduced water from either the same (control) or a different water mass (transplantation treatment). Additionally, mixtures of prokaryotes obtained from two different water masses were incubated in a mixture of virus-reduced water from the same water masses (control) or in virus-reduced water from the source water masses separately (mixing treatments). Pronounced differences in productivity-related parameters (prokaryotic leucine incorporation, prokaryotic and viral abundance) between water masses caused strong changes in viral lysis of prokaryotes. Often, mixing of water masses increased viral lysis of prokaryotes, indicating that lysogenic viruses were induced into the lytic cycle. Mixing-induced changes in viral lysis had a strong effect on the community composition of prokaryotes and viruses. Our data show that mixing of deep-sea water masses alters levels of viral lysis of prokaryotes and in many cases weakens the efficiency of the microbial loop by enhancing the recycling of organic carbon in the deep ocean. © 2018 by the Ecological Society of America.

  5. Effect of long-term application of biosolids for land reclamation on surface water chemistry.

    PubMed

    Tian, G; Granato, T C; Pietz, R I; Carlson, C R; Abedin, Z

    2006-01-01

    Biosolids are known to have a potential to restore degraded land, but the long-term impacts of this practice on the environment, including water quality, still need to be evaluated. The surface water chemistry (NO3-, NH4+, and total P, Cd, Cu, and Hg) was monitored for 31 yr from 1972 to 2002 in a 6000-ha watershed at Fulton County, Illinois, where the Metropolitan Water Reclamation District of Greater Chicago was restoring the productivity of strip-mined land using biosolids. The mean cumulative loading rates during the past 31 yr were 875 dry Mg ha(-1) for 1120-ha fields in the biosolids-amended watershed and 4.3 dry Mg ha(-1) for the 670-ha fields in the control watershed. Biosolids were injected into mine spoil fields as liquid fertilizer from 1972 to 1985, and incorporated as dewatered cake from 1980 to 1996 and air-dried solids from 1987 to 2002. The mean annual loadings of nutrients and trace elements from biosolids in 1 ha were 735 kg N, 530 kg P, 4.5 kg Cd, 30.7 kg Cu, and 0.11 kg Hg in the fields of the biosolids-amended watershed, and negligible in the fields of the control watershed. Sampling of surface water was conducted monthly in the 1970s, and three times per year in the 1980s and 1990s. The water samples were collected from 12 reservoirs and 2 creeks receiving drainage from the fields in the control watershed, and 8 reservoirs and 4 creeks associated with the fields in the biosolids-amended watershed for the analysis of NO3- -N (including NO2- N), NH4+-N, and total P, Cd, Cu, and Hg. Compared to the control (0.18 mg L(-1)), surface water NO3- -N in the biosolids-amended watershed (2.23 mg L(-1)) was consistently higher; however, it was still below the Illinois limit of 10 mg L(-1) for public and food-processing water supplies. Biosolids applications had a significant effect on mean concentrations of ammonium N (0.11 mg L(-1) for control and 0.24 mg L(-1) for biosolids) and total P (0.10 mg L(-1) for control and 0.16 mg L(-1) for biosolids) in surface water. Application of biosolids did not increase the concentrations of Cd and Hg in surface water. The elevation of Cu in surface water with biosolids application only occurred in some years of the first decade, when land-applied sludges contained high concentrations of trace metals, including Cu. In fact, following the promulgation of 40 CFR Part 503, the concentrations of all three metals fell below the method detection level (MDL) in surface water for nearly all samplings. Nitrate in the surface water tends to be higher in spring, and ammonium, total P, and total Hg in summer and fall. Mean nitrate, ammonium, and total phosphorus concentrations were found to be greater in creeks than reservoirs. The results indicate that application of biosolids for land reclamation at high loading rates from 1972 to 2002, with adequate runoff and soil erosion control, had only a minor impact on surface water quality.

  6. Intensive exploitation of a karst aquifer leads to Cryptosporidium water supply contamination.

    PubMed

    Khaldi, S; Ratajczak, M; Gargala, G; Fournier, M; Berthe, T; Favennec, L; Dupont, J P

    2011-04-01

    Groundwater from karst aquifers is an important source of drinking water worldwide. Outbreaks of cryptosporidiosis linked to surface water and treated public water are regularly reported. Cryptosporidium oocysts are resistant to conventional drinking water disinfectants and are a major concern for the water industry. Here, we examined conditions associated with oocyst transport along a karstic hydrosystem, and the impact of intensive exploitation on Cryptosporidium oocyst contamination of the water supply. We studied a well-characterized karstic hydrosystem composed of a sinkhole, a spring and a wellbore. Thirty-six surface water and groundwater samples were analyzed for suspended particulate matter, turbidity, electrical conductivity, and Cryptosporidium and Giardia (oo)cyst concentrations. (Oo)cysts were identified and counted by means of solid-phase cytometry (ChemScan RDI(®)), a highly sensitive method. Cryptosporidium oocysts were detected in 78% of both surface water and groundwater samples, while Giardia cysts were found in respectively 22% and 8% of surface water and groundwater samples. Mean Cryptosporidium oocyst concentrations were 29, 13 and 4/100 L at the sinkhole, spring and wellbore, respectively. Cryptosporidium oocysts were transported from the sinkhole to the spring and the wellbore, with respective release rates of 45% and 14%, suggesting that oocysts are subject to storage and remobilization in karst conduits. Principal components analysis showed that Cryptosporidium oocyst concentrations depended on variations in hydrological forcing factors. All water samples collected during intensive exploitation contained oocysts. Control of Cryptosporidium oocyst contamination during intensive exploitation is therefore necessary to ensure drinking water quality. Copyright © 2011. Published by Elsevier Ltd.

  7. Biogeochemical and hydrological controls in mobilizing Se in a saline wetland environment

    NASA Astrophysics Data System (ADS)

    Datta, S.; Hettiarachchi, G. M.; Crawford, M.; Karna, R.; Allmendinger, N. E.; Khatiwada, R.

    2010-12-01

    Selenium (Se) contamination in watersheds remains a challenge to water and land and wildlife managers throughout the west and mid west of US. In that sense, understanding the fundamentals of Se mobilization, fixation and bioconcentration is the current research endeavor. The challenge for Se research is developing watershed-geochemical models that are well founded in Se geochemical/biologcial principles that can be applied in a wide range of situations to inform decisions. Pariette Wetlands, a 9000 acre Bureau of Land Management controlled wetland system composed of 20 ponds located at the confluence of Pariette Draw and the Green River is the present location of this study. The agricultural and irrigation practices and the water-rock interactions leading to salinization can be associated with changes in Se chemistry in the rivers. Since its inception Pariette Wetlands has been home to a rich and diverse wetland ecosystem located in the arid Uintah Basin of Northeastern Utah. Detailed sampling of surficial sediments (0-1 m) from stream banks, channel beds and for water sampling have been undergone in 2 separate field trips throughout the entire reach of the wetland. To establish Pariette Draw’s contribution of Se to the Green river, water and sediments were also sampled from the Green River up and downstream of its confluence with Pariette Draw. In situ measurements of water parameters within the wetland suggest a clear trend of increased pH from upstream, 8, to downstream, 9.2 and combined with TDS suggest a pH controlled saline environment system. The headwaters near Flood Control Dam have an added input of Se from a possible irrigation source upstream in Pleasant Valley area while Se drastically decreases downstream towards the Red Head Pond. Se fractionation in sediments is being analyzed via a sequential extraction procedure to locate the labile fractions of mostly inorganic bound Se. Solid state speciation of Se via μ-XRF aided μ-XANES is being combined with HPLC-MS measured speciation of Se in the water samples. The μ-XRF mapping of Se indicated that Se was highly localized in these surficial sediment samples and therefore, spatially resolved µ-XANES was essential for Se speciation. The µ-XANES speciation of these surficial sediments showed that Se speciation to significantly vary among the 2 sets of seasonal samples (saturated year long versus saturated only seasonally) hence suggesting that continuous drying and wetting cycles or continuous saturation in this environment did have significant impact on sequestration and bioavailability of Se. This work focuses on using this watershed as 'field laboratories' to expand on predicting selenium concentrations from general/fundamental understanding of first-order principles

  8. Efficacy of water-dispersible formulations of biological control strains of Aspergillus flavus for aflatoxin management in corn.

    PubMed

    Weaver, Mark A; Abbas, Hamed K; Jin, Xixuan; Elliott, Brad

    2016-01-01

    Field experiments were conducted in 2011 and 2012 to evaluate the efficacy of water-dispersible granule (WDG) formulations of biocontrol strains of Aspergillus flavus in controlling aflatoxin contamination of corn. In 2011, when aflatoxin was present at very high levels, there was no WDG treatment that could provide significant protection against aflatoxin contamination. The following year a new WDG formulation was tested that resulted in 100% reduction in aflatoxin in one field experiment and ≥ 49% reduction in all five WDG treatments with biocontrol strain 21882. Large sampling error, however, limited the resolution of various treatment effects. Corn samples were also subjected to microbial analysis to understand better the mechanisms of successful biocontrol. In the samples examined here, the size of the A. flavus population on the grain was associated with the amount of aflatoxin, but the toxigenic status of that population was a poor predictor of aflatoxin concentration.

  9. SU-F-J-193: Efficient Dose Extinction Method for Water Equivalent Path Length (WEPL) of Real Tissue Samples for Validation of CT HU to Stopping Power Conversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, R; Baer, E; Jee, K

    Purpose: For proton therapy, an accurate model of CT HU to relative stopping power (RSP) conversion is essential. In current practice, validation of these models relies solely on measurements of tissue substitutes with standard compositions. Validation based on real tissue samples would be much more direct and can address variations between patients. This study intends to develop an efficient and accurate system based on the concept of dose extinction to measure WEPL and retrieve RSP in biological tissue in large number of types. Methods: A broad AP proton beam delivering a spread out Bragg peak (SOBP) is used to irradiatemore » the samples with a Matrixx detector positioned immediately below. A water tank was placed on top of the samples, with the water level controllable in sub-millimeter by a remotely controlled dosing pump. While gradually lowering the water level with beam on, the transmission dose was recorded at 1 frame/sec. The WEPL were determined as the difference between the known beam range of the delivered SOBP (80%) and the water level corresponding to 80% of measured dose profiles in time. A Gammex 467 phantom was used to test the system and various types of biological tissue was measured. Results: RSP for all Gammex inserts, expect the one made with lung-450 material (<2% error), were determined within ±0.5% error. Depends on the WEPL of investigated phantom, a measurement takes around 10 min, which can be accelerated by a faster pump. Conclusion: Based on the concept of dose extinction, a system was explored to measure WEPL efficiently and accurately for a large number of samples. This allows the validation of CT HU to stopping power conversions based on large number of samples and real tissues. It also allows the assessment of beam uncertainties due to variations over patients, which issue has never been sufficiently studied before.« less

  10. Atrazine remediation in wetland microcosms.

    PubMed

    Runes, H B; Bottomley, P J; Lerch, R N; Jenkins, J J

    2001-05-01

    Laboratory wetland microcosms were used to study treatment of atrazine in irrigation runoff by a field-scale-constructed wetland under controlled conditions. Three experiments, in which 1 ppm atrazine was added to the water column of three wetland, one soil control, and one water control microcosm, were conducted. Atrazine dissipation from the water column and degradate formation (deethylatrazine [DEA]; deisopropylatrazine [DIA]; and hydroxyatrazine [HA]) were monitored. Atrazine dissipation from the water column of wetland microcosms was biphasic. Less than 12% of the atrazine applied to wetland microcosms remained in the water column on day 56. Atrazine degradates were observed in water and sediment, with HA the predominant degradate. Analysis of day 56 sediment samples indicated that a significant portion of the initial application was detected as the parent compound and HA. Most probable number (MPN) assays demonstrated that atrazine degrader populations were small in wetland sediment. Wetland microcosms were able to reduce atrazine concentration in the water column via sorption and degradation. Based on results from this study, it is hypothesized that plant uptake contributed to atrazine dissipation from the water column.

  11. The evolution of the Cappadocia Geothermal Province, Anatolia (Turkey): geochemical and geochronological evidence

    NASA Astrophysics Data System (ADS)

    Şener, M. Furkan; Şener, Mehmet; Uysal, I. Tonguç

    2017-12-01

    Cappadocia Geothermal Province (CGP), central Turkey, consists of nine individual geothermal regions controlled by active regional fault systems. This paper examines the age dating of alteration minerals and the geochemistry (trace elements and isotopes) of the alteration minerals and geothermal waters, to assess the evolution of CGP in relation to regional tectonics. Ar-Ar age data of jarosite and alunite show that the host rocks were exposed to oxidizing conditions near the Earth's surface at about 5.30 Ma. Based on the δ18O-δD relationhip, water samples had a high altitude meteoric origin. The δ34S values of jarosite and alunite indicate that water samples from the southern part of the study area reached the surface after circulation through volcanic rocks, while northern samples had traveled to the surface after interacting with evaporates at greater depths. REY (rare earth elements and yttrium) diagrams of alteration minerals (especially illite, jarosite and alunite) from rock samples, taken from the same locations as the water samples, display a similar REY pattern to water samples. This suggests that thermal fluids, which reached the surface along a fault zone and caused the mineral alteration in the past, had similar chemical composition to the current geothermal water. The geothermal conceptual model, which defines a volcanically heated reservoir and cap rocks, suggests there are no structural drawbacks to the use of the CGP geothermal system as a resource. However, fluid is insufficient to drive the geothermal system as a result of scanty supply of meteoric water due to evaporation significantly exceeding rainfall.

  12. [Partial pressure of CO2 and CO2 degassing fluxes of Huayuankou and Xiaolangdi Station affected by Xiaolangdi Reservoir].

    PubMed

    Zhang, Yong-ling; Yang, Xiao-lin; Zhang, Dong

    2015-01-01

    According to periodic sampling analysis per month in Xiaolangdi station and Huayuankou station from November 2011 to October 2012, combined with continuous sampling analysis of Xiaolangdi Reservoir during runoff and sediment control period in 2012, partial pressure of CO2 (pCO2) in surface water were calculated based on Henry's Law, pCO2 features and air-water CO2 degassing fluxes of Huayuankou station and Xiaolangdi station affected by Xiaolangdi Reservoir were studied. The results were listed as follows, when Xiaolangdi Reservoir operated normally, pCO2 in surface water of Xiaolangdi station and Huayuankou station varied from 82 to 195 Pa and from 99 to 228 Pa, moreover, pCO2 in surface water from July to September were distinctly higher than those in other months; meanwhile, pCO, in surface water from Huayuankou station were higher than that from Xiaolangdi station. During runoff and sediment control period of Xiaolangdi Reservoir, two hydrological stations commonly indicated that pCO2 in surface water during water draining were obviously lower than those during sediment releasing. Whether in the period of normal operation or runoff and sediment control, pCO2 in surface water had positive relations to DIC content in two hydrological stations. Since the EpCO,/AOU value was higher than the theoretical value of 0. 62, the biological aerobic respiration effect had distinct contribution to pCO2. Throughout the whole year, air-water CO2 degassing fluxes from Xiaolangdi station and Huayuankou station were 0.486 p.mol (m2 s) -l and 0.588 pmol (m2 x s)(-1) respectively; When Xiaolangdi Reservoir operated normally, air-water CO, degassing fluxes in Huayuankou station were higher than that in Xiaolangdi station; during runoff and sediment control from Xiaolangdi Reservoir, two hydrological stations had one observation result in common, namely, air-water CO2 degassing fluxes in the period of water draining were obviously lower than that in the period of sediment releasing.

  13. Groundwater-Quality Data in the Madera-Chowchilla Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Fram, Miranda S.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 860-square-mile Madera-Chowchilla study unit (MADCHOW) was investigated in April and May 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within MADCHOW, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 35 wells in Madera, Merced, and Fresno Counties. Thirty of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and five more were selected to provide additional sampling density to aid in understanding processes affecting groundwater quality (flow-path wells). Detection summaries in the text and tables are given for grid wells only, to avoid over-representation of the water quality in areas adjacent to flow-path wells. Groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], low-level 1,2-dibromo-3-chloropropane [DBCP] and 1,2-dibromoethane [EDB], pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds), constituents of special interest (N-nitrosodimethylamine [NDMA], perchlorate, and low-level 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents (uranium isotopes, and gross alpha and gross beta particle activities). Naturally occurring isotopes and geochemical tracers (stable isotopes of hydrogen, oxygen, and carbon, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, approximately 300 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 11 percent of the wells sampled for each analysis, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from MADCHOW wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides

  14. Seasonal distribution of Legionella spp. and L. pneumophila in a river in Taiwan evaluated with culture-confirmed and direct DNA extraction methods

    NASA Astrophysics Data System (ADS)

    Tung, Min-Che; Chang, Tien-Yu; Hsu, Bing-Mu; Shen, Shu-Min; Huang, Jen-Te; Kao, Po-Min; Chiu, Yi-Chou; Fan, Cheng-Wei; Huang, Yu-Li

    2013-07-01

    In this study, we evaluated the presence and amount of Legionella in along a river in Taiwan, and the relations between seasonal distribution of Legionella spp. and geographic characteristics in the watershed were also evaluated. Water samples were pre-treated and analyzed with culture-confirmed and direct DNA extraction methods. For culture-confirmed method, water samples were cultivated through a series of selective media, and candidate colonies were confirmed by PCR. For direct DNA extraction method, direct DNA extraction was performed from pre-treated water samples. The DNA extracts were analyzed with PCR and DNA sequence analysis for species determination, quantitative PCR (qPCR) was performed to quantify Legionella concentration in the water sample. In all, 150 water samples were included in this study, with 73 (48.6%) water samples detected with Legionella spp., and 17 with L. pneumophila. Over 80% Legionella spp. detections were through direct DNA extraction method, but more than 80% L. pneumophila detections were through culture-confirmed method. While detection of Legionella spp. was done with two methods, positive results were found through only one method. Legionella spp. was detected in all seasons with detection rate ranging between 34.3-58.8% and seasonal average concentration from 1.9 × 102 to 7.1 × 103 CFU/L. Most of the L. pneumophila detections were from samples collected in fall (38.2%) and summer (6.0%), which also coincided with increased cases of Legionellosis reported through Center of Disease Control in Taiwan. The high prevalence and concentration of Legionella spp. and L. pneumophila in the surface waters should be further evaluated for potential health risks.

  15. Determination of geostatistically representative sampling locations in Porsuk Dam Reservoir (Turkey)

    NASA Astrophysics Data System (ADS)

    Aksoy, A.; Yenilmez, F.; Duzgun, S.

    2013-12-01

    Several factors such as wind action, bathymetry and shape of a lake/reservoir, inflows, outflows, point and diffuse pollution sources result in spatial and temporal variations in water quality of lakes and reservoirs. The guides by the United Nations Environment Programme and the World Health Organization to design and implement water quality monitoring programs suggest that even a single monitoring station near the center or at the deepest part of a lake will be sufficient to observe long-term trends if there is good horizontal mixing. In stratified water bodies, several samples can be required. According to the guide of sampling and analysis under the Turkish Water Pollution Control Regulation, a minimum of five sampling locations should be employed to characterize the water quality in a reservoir or a lake. The European Union Water Framework Directive (2000/60/EC) states to select a sufficient number of monitoring sites to assess the magnitude and impact of point and diffuse sources and hydromorphological pressures in designing a monitoring program. Although existing regulations and guidelines include frameworks for the determination of sampling locations in surface waters, most of them do not specify a procedure in establishment of monitoring aims with representative sampling locations in lakes and reservoirs. In this study, geostatistical tools are used to determine the representative sampling locations in the Porsuk Dam Reservoir (PDR). Kernel density estimation and kriging were used in combination to select the representative sampling locations. Dissolved oxygen and specific conductivity were measured at 81 points. Sixteen of them were used for validation. In selection of the representative sampling locations, care was given to keep similar spatial structure in distributions of measured parameters. A procedure was proposed for that purpose. Results indicated that spatial structure was lost under 30 sampling points. This was as a result of varying water quality in the reservoir due to inflows, point and diffuse inputs, and reservoir hydromorphology. Moreover, hot spots were determined based on kriging and standard error maps. Locations of minimum number of sampling points that represent the actual spatial structure of DO distribution in the Porsuk Dam Reservoir

  16. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; comparison of a nitric acid in-bottle digestion procedure to other whole-water digestion procedures

    USGS Publications Warehouse

    Garbarino, John R.; Hoffman, Gerald L.

    1999-01-01

    A hydrochloric acid in-bottle digestion procedure is used to partially digest wholewater samples prior to determining recoverable elements by various analytical methods. The use of hydrochloric acid is problematic for some methods of analysis because of spectral interference. The inbottle digestion procedure has been modified to eliminate such interference by using nitric acid instead of hydrochloric acid in the digestion. Implications of this modification are evaluated by comparing results for a series of synthetic whole-water samples. Results are also compared with those obtained by using U.S. Environmental Protection Agency (1994) (USEPA) Method 200.2 total-recoverable digestion procedure. Percentage yields that use the nitric acid inbottle digestion procedure are within 10 percent of the hydrochloric acid in-bottle yields for 25 of the 26 elements determined in two of the three synthetic whole-water samples tested. Differences in percentage yields for the third synthetic whole-water sample were greater than 10 percent for 16 of the 26 elements determined. The USEPA method was the most rigorous for solubilizing elements from particulate matter in all three synthetic whole-water samples. Nevertheless, the variability in the percentage yield by using the USEPA digestion procedure was generally greater than the in-bottle digestion procedure, presumably because of the difficulty in controlling the digestion conditions accurately.

  17. Development and evaluation of a culture-independent method for source determination of fecal wastes in surface and storm waters using reverse transcriptase-PCR detection of FRNA coliphage genogroup gene sequences.

    PubMed

    Paar, Jack; Doolittle, Mark M; Varma, Manju; Siefring, Shawn; Oshima, Kevin; Haugland, Richard A

    2015-05-01

    A method, incorporating recently improved reverse transcriptase-PCR primer/probe assays and including controls for detecting interferences in RNA recovery and analysis, was developed for the direct, culture-independent detection of genetic markers from FRNA coliphage genogroups I, II & IV in water samples. Results were obtained from an initial evaluation of the performance of this method in analyses of waste water, ambient surface water and stormwater drain and outfall samples from predominantly urban locations. The evaluation also included a comparison of the occurrence of the FRNA genetic markers with genetic markers from general and human-related bacterial fecal indicators determined by current or pending EPA-validated qPCR methods. Strong associations were observed between the occurrence of the putatively human related FRNA genogroup II marker and the densities of the bacterial markers in the stormwater drain and outfall samples. However fewer samples were positive for FRNA coliphage compared to either the general bacterial fecal indicator or the human-related bacterial fecal indicator markers particularly for ambient water samples. Together, these methods show promise as complementary tools for the identification of contaminated storm water drainage systems as well as the determination of human and non-human sources of contamination. Published by Elsevier B.V.

  18. The Effects of Potato Puree and Bread Crumbs on Some Quality Characteristics of Low Fat Meatballs

    PubMed Central

    Ergezer, Haluk; Akcan, Tolga; Serdaroğlu, Meltem

    2014-01-01

    The purpose of this study was to determine the effects of using different amounts of potato puree (PP) (10 or 20%) and 10% bread crumbs (BC) as an extender and also control samples (C) with no added extender on chemical composition, energy values, cooking analyses, colour measurements, water holding capacity (WHC), penetration values, thiobarbituric acid value (TBA) and sensory analyses of meatballs. Meatball samples were cooked in a pre-heated 180℃ electric oven. Uncooked meatballs formulated with 20% PP had the highest moisture content. No significant differences were recorded for protein contents of uncooked samples. The highest cooking yield was found in samples extended with 10% BC. Increasing PP from 10% to 20% increased cooking yield of meatballs. 20% PP increased moisture and fat retention values and water holding capacity of meatballs. Meatballs with 10% BC had the lowest (the hardness in the texture) and meatballs with the 20% PP had the highest (the softness in the texture) penetration values. Formulating meatballs at a level of 20% resulted lower L* values. TBA values of control samples were higher than in PP added samples at the end of the storage period. Flavour scores for meatballs formulated with PP were higher than control and meatballs formulated with BC. Meatballs formulated with 10% PP had similar overall acceptability with meatballs added with 10% BC. PMID:26761488

  19. The Effects of Potato Puree and Bread Crumbs on Some Quality Characteristics of Low Fat Meatballs.

    PubMed

    Ergezer, Haluk; Akcan, Tolga; Serdaroğlu, Meltem

    2014-01-01

    The purpose of this study was to determine the effects of using different amounts of potato puree (PP) (10 or 20%) and 10% bread crumbs (BC) as an extender and also control samples (C) with no added extender on chemical composition, energy values, cooking analyses, colour measurements, water holding capacity (WHC), penetration values, thiobarbituric acid value (TBA) and sensory analyses of meatballs. Meatball samples were cooked in a pre-heated 180℃ electric oven. Uncooked meatballs formulated with 20% PP had the highest moisture content. No significant differences were recorded for protein contents of uncooked samples. The highest cooking yield was found in samples extended with 10% BC. Increasing PP from 10% to 20% increased cooking yield of meatballs. 20% PP increased moisture and fat retention values and water holding capacity of meatballs. Meatballs with 10% BC had the lowest (the hardness in the texture) and meatballs with the 20% PP had the highest (the softness in the texture) penetration values. Formulating meatballs at a level of 20% resulted lower L* values. TBA values of control samples were higher than in PP added samples at the end of the storage period. Flavour scores for meatballs formulated with PP were higher than control and meatballs formulated with BC. Meatballs formulated with 10% PP had similar overall acceptability with meatballs added with 10% BC.

  20. A Improved and Highly Effective Seabed Surface Sand Sampling Device

    NASA Astrophysics Data System (ADS)

    Liu, Ying

    2017-04-01

    In marine geology research, it is necessary to obtain a sufficient quantity of seabed surface samples, while also ensuring that the samples are in their original state. Currently, there are a number of seabed surface sampling devices available, but it is very difficult to obtain sand samples using ordinary seabed surface sampling devices, whereas machine-controlled seabed surface sampling devices are unable to dive into deeper regions of water. To obtain larger quantities of samples in their original states, many researchers have tried to improve seabed surface sampling devices, but these efforts have generally produced ambiguous results. To resolve the aforementioned issue, we have designed an improved and highly effective seabed surface sand sampling device, which incorporates the strengths of a variety of sampling devices; it is capable of diving into deeper water regions to obtain sand samples, and is also suited for use in streams, rivers, lakes and seas with varying levels of flow velocities and depth.

  1. Presence of Emerging Per- and Polyfluoroalkyl Substances (PFASs) in River and Drinking Water near a Fluorochemical Production Plant in the Netherlands.

    PubMed

    Gebbink, Wouter A; van Asseldonk, Laura; van Leeuwen, Stefan P J

    2017-10-03

    The present study investigated the presence of legacy and emerging per- and polyfluoroalkyl substances (PFASs) in river water collected in 2016 up- and downstream from a fluorochemical production plant, as well as in river water from control sites, in The Netherlands. Additionally, drinking water samples were collected from municipalities in the vicinity from the production plant, as well as in other regions in The Netherlands. The PFOA replacement chemical GenX was detected at all downstream river sampling sites with the highest concentration (812 ng/L) at the first sampling location downstream from the production plant, which was 13 times higher than concentrations of sum perfluoroalkylcarboxylic acids and perfluoroalkanesulfonates (∑PFCA+∑PFSA). Using high resolution mass spectrometry, 11 polyfluoroalkyl acids belonging to the C 2n H 2n F 2n O 2 , C 2n H 2n+2 F 2n SO 4 or C 2n+1 H 2n F 2n+4 SO 4 homologue series were detected, but only in downstream water samples. These emerging PFASs followed a similar distribution as GenX among the downstream sampling sites, suggesting the production plant as the source. Polyfluoroalkyl sulfonates (C 2n H 2 F 4n SO 3 ) were detected in all collected river water samples, and therefore appear to be ubiquitous contaminants in Dutch rivers. GenX was also detected in drinking water collected from 3 out of 4 municipalities in the vicinity of the production plant, with highest concentration at 11 ng/L. Drinking water containing the highest level of GenX also contained two C 2n H 2n F 2n O 2 homologues.

  2. Effects of land use and seasonality on stream water quality in a small tropical catchment: The headwater of Córrego Água Limpa, São Paulo (Brazil).

    PubMed

    Rodrigues, Valdemir; Estrany, Joan; Ranzini, Mauricio; de Cicco, Valdir; Martín-Benito, José Mª Tarjuelo; Hedo, Javier; Lucas-Borja, Manuel E

    2018-05-01

    Stream water quality is controlled by the interaction of natural and anthropogenic factors over a range of temporal and spatial scales. Among these anthropogenic factors, land cover changes at catchment scale can affect stream water quality. This work aims to evaluate the influence of land use and seasonality on stream water quality in a representative tropical headwater catchment named as Córrego Água Limpa (Sao Paulo, Brasil), which is highly influenced by intensive agricultural activities and urban areas. Two systematic sampling approach campaigns were implemented with six sampling points along the stream of the headwater catchment to evaluate water quality during the rainy and dry seasons. Three replicates were collected at each sampling point in 2011. Electrical conductivity, nitrates, nitrites, sodium superoxide, Chemical Oxygen Demand (DQO), colour, turbidity, suspended solids, soluble solids and total solids were measured. Water quality parameters differed among sampling points, being lower at the headwater sampling point (0m above sea level), and then progressively higher until the last downstream sampling point (2500m above sea level). For the dry season, the mean discharge was 39.5ls -1 (from April to September) whereas 113.0ls -1 were averaged during the rainy season (from October to March). In addition, significant temporal and spatial differences were observed (P<0.05) for the fourteen parameters during the rainy and dry period. The study enhance significant relationships among land use and water quality and its temporal effect, showing seasonal differences between the land use and water quality connection, highlighting the importance of multiple spatial and temporal scales for understanding the impacts of human activities on catchment ecosystem services. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Presence of Emerging Per- and Polyfluoroalkyl Substances (PFASs) in River and Drinking Water near a Fluorochemical Production Plant in the Netherlands

    PubMed Central

    2017-01-01

    The present study investigated the presence of legacy and emerging per- and polyfluoroalkyl substances (PFASs) in river water collected in 2016 up- and downstream from a fluorochemical production plant, as well as in river water from control sites, in The Netherlands. Additionally, drinking water samples were collected from municipalities in the vicinity from the production plant, as well as in other regions in The Netherlands. The PFOA replacement chemical GenX was detected at all downstream river sampling sites with the highest concentration (812 ng/L) at the first sampling location downstream from the production plant, which was 13 times higher than concentrations of sum perfluoroalkylcarboxylic acids and perfluoroalkanesulfonates (∑PFCA+∑PFSA). Using high resolution mass spectrometry, 11 polyfluoroalkyl acids belonging to the C2nH2nF2nO2, C2nH2n+2F2nSO4 or C2n+1H2nF2n+4SO4 homologue series were detected, but only in downstream water samples. These emerging PFASs followed a similar distribution as GenX among the downstream sampling sites, suggesting the production plant as the source. Polyfluoroalkyl sulfonates (C2nH2F4nSO3) were detected in all collected river water samples, and therefore appear to be ubiquitous contaminants in Dutch rivers. GenX was also detected in drinking water collected from 3 out of 4 municipalities in the vicinity of the production plant, with highest concentration at 11 ng/L. Drinking water containing the highest level of GenX also contained two C2nH2nF2nO2 homologues. PMID:28853567

  4. Trends in analytical methodologies for the determination of alkylphenols and bisphenol A in water samples.

    PubMed

    Salgueiro-González, N; Muniategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D

    2017-04-15

    In the last decade, the impact of alkylphenols and bisphenol A in the aquatic environment has been widely evaluated because of their high use in industrial and household applications as well as their toxicological effects. These compounds are well-known endocrine disrupting compounds (EDCs) which can affect the hormonal system of humans and wildlife, even at low concentrations. Due to the fact that these pollutants enter into the environment through waters, and it is the most affected compartment, analytical methods which allow the determination of these compounds in aqueous samples at low levels are mandatory. In this review, an overview of the most significant advances in the analytical methodologies for the determination of alkylphenols and bisphenol A in waters is considered (from 2002 to the present). Sample handling and instrumental detection strategies are critically discussed, including analytical parameters related to quality assurance and quality control (QA/QC). Special attention is paid to miniaturized sample preparation methodologies and approaches proposed to reduce time- and reagents consumption according to Green Chemistry principles, which have increased in the last five years. Finally, relevant applications of these methods to the analysis of water samples are examined, being wastewater and surface water the most investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Controls on water vapor isotopes over Roorkee, India: Impact of convective activities and depression systems

    NASA Astrophysics Data System (ADS)

    Saranya, P.; Krishan, Gopal; Rao, M. S.; Kumar, Sudhir; Kumar, Bhishm

    2018-02-01

    The study evaluates the water vapor isotopic compositions and its controls with special reference to Indian Summer Monsoon (ISM) season at Roorkee, India. Precipitation is usually a discrete event spatially and temporally in this part of the country, therefore, the information provided is limited, while, the vapors have all time availability and have a significant contribution in the hydrological cycle locally or over a regional scale. Hence for understanding the processes altering the various sources, its isotopic signatures were studied. The Isotope Water Vapour Line (Iso Val) was drawn together with the Global Meteoric Water Line (GMWL) and the best fit line was δD = 5.42 * δ18O + 27.86. The precipitation samples were also collected during the study period and were best fitted with δD = 8.20(±0.18) * δ18O + 9.04(±1.16) in the Local Meteoric Water Line (LMWL). From the back trajectory analysis of respective vapor samples, it is unambiguous that three major sources viz; local vapor, western disturbance and monsoon vapor are controlling the fate of moisture over Roorkee. The d-excess in ground-level vapor (GLV) reveals the supply of recycled moisture from continental water bodies and evapo-transpiration as additional moisture sources to the study area. The intensive depletion in isotopic ratios was associated with the large-scale convective activity and low-pressure/cyclonic/depression systems formed over Bay of Bengal.

  6. Analytical methods of the U.S. Geological Survey's New York District Water-Analysis Laboratory

    USGS Publications Warehouse

    Lawrence, Gregory B.; Lincoln, Tricia A.; Horan-Ross, Debra A.; Olson, Mark L.; Waldron, Laura A.

    1995-01-01

    The New York District of the U.S. Geological Survey (USGS) in Troy, N.Y., operates a water-analysis laboratory for USGS watershed-research projects in the Northeast that require analyses of precipitation and of dilute surface water and soil water for major ions; it also provides analyses of certain chemical constituents in soils and soil gas samples.This report presents the methods for chemical analyses of water samples, soil-water samples, and soil-gas samples collected in wateshed-research projects. The introduction describes the general materials and technicques for each method and explains the USGS quality-assurance program and data-management procedures; it also explains the use of cross reference to the three most commonly used methods manuals for analysis of dilute waters. The body of the report describes the analytical procedures for (1) solution analysis, (2) soil analysis, and (3) soil-gas analysis. The methods are presented in alphabetical order by constituent. The method for each constituent is preceded by (1) reference codes for pertinent sections of the three manuals mentioned above, (2) a list of the method's applications, and (3) a summary of the procedure. The methods section for each constitutent contains the following categories: instrumentation and equipment, sample preservation and storage, reagents and standards, analytical procedures, quality control, maintenance, interferences, safety considerations, and references. Sufficient information is presented for each method to allow the resulting data to be appropriately used in environmental investigations.

  7. Fluoride estimation and its correlation with other physicochemical parameters in drinking water of some areas of Balochistan, Pakistan.

    PubMed

    Chandio, Tasawar Ali; Khan, Muhammad Nasiruddin; Sarwar, Anila

    2015-08-01

    The fluoride level in drinking water is an important parameter and has to be controlled in order to prevent dental and skeletal fluorosis. The objective of this study is to assess fluoride content and other water quality parameters in the samples taken from open wells, tube wells, and karezes of Mastung, Mangochar, and Pringabad areas of Balochistan province. A total number of 96 drinking water samples out of 150 were found unfit for human consumption. Area-wise analysis show that the samples from 39 sites from Mastung, 12 from Mangochar, and 13 from Pringabad were found in the risk of dental fluorosis of mild to severe nature. However, 12 sampling sites from Mastung, 8 from Mangochar, and 2 from Pringabad were identified as the risks of mottling and skeletal fluorosis or other bone abnormalities. The highest concentration of F(-) has been observed as 14 mg L(-1) in Mastung. Correlation analysis show that fluoride solubility in drinking water is pH dependent; and the salts of Ca(2+), Na(+), K(+), Cl(-), and SO4(2-) contribute to attain the favorable pH for dissolution of fluoride compounds in drinking water. Principal component analysis shows that the geochemical composition of the rocks is only responsible for groundwater contamination. On the basis of the results, defloridation of the identified sampling sites and continuous monitoring of drinking water at regular basis is recommended at government level to avoid further fluorosis risks.

  8. Controls on Methane Occurrences in Aquifers Overlying the Eagle Ford Shale Play, South Texas.

    PubMed

    Nicot, Jean-Philippe; Larson, Toti; Darvari, Roxana; Mickler, Patrick; Uhlman, Kristine; Costley, Ruth

    2017-07-01

    Assessing natural vs. anthropogenic sources of methane in drinking water aquifers is a critical issue in areas of shale oil and gas production. The objective of this study was to determine controls on methane occurrences in aquifers in the Eagle Ford Shale play footprint. A total of 110 water wells were tested for dissolved light alkanes, isotopes of methane, and major ions, mostly in the eastern section of the play. Multiple aquifers were sampled with approximately 47 samples from the Carrizo-Wilcox Aquifer (250-1200 m depth range) and Queen City-Sparta Aquifer (150-900 m depth range) and 63 samples from other shallow aquifers but mostly from the Catahoula Formation (depth <150 m). Besides three shallow wells with unambiguously microbial methane, only deeper wells show significant dissolved methane (22 samples >1 mg/L, 10 samples >10 mg/L). No dissolved methane samples exhibit thermogenic characteristics that would link them unequivocally to oil and gas sourced from the Eagle Ford Shale. In particular, the well water samples contain very little or no ethane and propane (C1/C2+C3 molar ratio >453), unlike what would be expected in an oil province, but they also display relatively heavier δ 13 C methane (>-55‰) and δD methane (>-180‰). Samples from the deeper Carrizo and Queen City aquifers are consistent with microbial methane sourced from syndepositional organic matter mixed with thermogenic methane input, most likely originating from deeper oil reservoirs and migrating through fault zones. Active oxidation of methane pushes δ 13 C methane and δD methane toward heavier values, whereas the thermogenic gas component is enriched with methane owing to a long migration path resulting in a higher C1/C2+C3 ratio than in the local reservoirs. © 2017, National Ground Water Association.

  9. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling

    USGS Publications Warehouse

    Antweiler, Ronald C.; Writer, Jeffrey H.; Murphy, Sheila F.

    2014-01-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations – such as missing the Lagrangian parcel by less than 1 h – can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed “verified Lagrangian” sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2–4 h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we show how data from other studies can be corrected.

  10. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling.

    PubMed

    Antweiler, Ronald C; Writer, Jeffrey H; Murphy, Sheila F

    2014-02-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations - such as missing the Lagrangian parcel by less than 1h - can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed "verified Lagrangian" sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2-4h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we show how data from other studies can be corrected. © 2013.

  11. Ground-Water Quality Data in the Owens and Indian Wells Valleys Study Unit, 2006: Results from the California GAMA Program

    USGS Publications Warehouse

    Densmore, Jill N.; Fram, Miranda S.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 1,630 square-mile Owens and Indian Wells Valleys study unit (OWENS) was investigated in September-December 2006 as part of the Priority Basin Project of Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in collaboration with the California State Water Resources Control Board (SWRCB). The Owens and Indian Wells Valleys study was designed to provide a spatially unbiased assessment of raw ground-water quality within OWENS study unit, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 74 wells in Inyo, Kern, Mono, and San Bernardino Counties. Fifty-three of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 21 wells were selected to evaluate changes in water chemistry in areas of interest (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater- indicator compounds], constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), and 1,2,3- trichloropropane (1,2,3-TCP)], naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water], and dissolved noble gases also were measured to help identify the source and age of the sampled ground water. This study evaluated the quality of raw ground water in the aquifer in the OWENS study unit and did not attempt to evaluate the quality of treated water delivered to consumers. Water supplied to consumers typically is treated after withdrawal from the ground, disinfected, and blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and non-regulatory thresholds established for aesthetic concerns (secondary maximum contamination levels, SMCL-CA) by CDPH. VOCs and pesticides were detected in samples from less than one-third of the grid wells; all detections were below health-based thresholds, and most were less than one-one hundredth of threshold values. All detections of perchlorate and nutrients in samples from OWENS were below health-based thresholds. Most detections of trace elements in ground-water samples from OWENS wells were below health-based thresholds. In samples from the 53 grid wells, three constituents were detected at concentrations above USEPA maximum contaminant levels: arsenic in 5 samples, uranium in 4 samples, and fluoride in 1 sample. Two constituents were detected at concentrations above CDPH notification levels (boron in 9 samples and vanadium in 1 sample), and two were above USEPA lifetime health advisory levels (molybdenum in 3 samples and strontium in 1 sample). Most of the samples from OWENS wells had concentrations of major elements, TDS, and trace elements below the non-enforceable standards set for aesthetic concerns. Samples from nine grid wells had concentrations of manganese, iron, or TDS above the SMCL-CAs.

  12. Quality of surface water before implementation of a flood-control project in Chaska, Minnesota

    USGS Publications Warehouse

    Tornes, L.H.

    1981-01-01

    Samples were collected for 1 year from East Creek, Chaska Creek, and Courthouse Lake in Chaska, Minnesota, to determine the water quality before implementation of a flood-control project proposed by the U.S. Army Corps of Engineers. The creeks had similar water-quality characteristics. Data indicate that ground water may be the primary source of dissolved solids, sulfate, chloride, and chromium in the creeks. The pesticides alachlor, atrazine, simazine, and 2,4-D were found in water samples from both creeks but were well below the lethal concentrations for fish. Courthouse Lake, a 57-foot-deep stream-trout lake, had a mean summer trophic-state index of 35. Phytoplankton populations varied seasonally, and blue-green algae were predominant only in late summer. The algal-pollution index was highest in late summer, but did not provide evidence of high organic pollution. The apparently successful recovery of Courthouse Lake from past inundations by Minnesota River floodwaters having total phosphorus concentrations as high as 0.66 milligram per liter suggests that the lake, in time, will also recover from the added runoff expected as a result of implementing the flood-control project. The runoff could temporarily raise the total phosphorus concentration in the lake from 0.03 to 0.12 milligram per liter and raise the spring trophic-state index from 49 to 69.

  13. [Presence of Legionella spp. in household drinking water reservoirs in Resistencia, Chaco, Argentina. Preliminary report].

    PubMed

    Lösch, Liliana S; Merino, Luis A

    Legionella spp. is an environmental bacterium that can survive in a wide range of physicochemical conditions and may colonize distribution systems of drinking water and storage tanks. Legionella pneumophila is the major waterborne pathogen that can cause 90% of Legionnaires' disease cases. The aim of this study was to detect the presence of Legionella spp. in household drinking water tanks in the city of Resistencia, Chaco. The detection of Legionella in water samples was performed by culture methods as set out in ISO 11731:1998. Thirty two water samples were analyzed and Legionella spp. was recovered in 12 (37.5%) of them. The monitoring of this microorganism in drinking water is the first step towards addressing the control of its spread to susceptible hosts. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Analysis of Organohalogen Products From Chlorination of Natural Waters Under Simulated Biofouling Control Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bean, R. M.; Mann, D. C.; Riley, R. G.

    1980-06-01

    The products of low-level chlorination of natural waters from ten locations across the continental United States have been studied, with emphasis on volatile and lipophilic organohalogen components. A specially designed apparatus permitted continuous sampling and chlorination of water in a manner analogous to some types of cooling water treatments. Volatile components were analyzed using headspace, purge-and-trap, and resin adsorption methods. The less-volatile components were collected by passing large volumes of the chlorinated water over XAD-2 columns. Total organic halogen collected on XAD resins was compared with the halogen contribution of haloform compounds. The XAD samples were further separated into fractionsmore » according to molecular weight and polarity using liquid chrOmatography. These studies indicate that haloforms are the most abundant lipophilic halogenated products formed from low-level chlorination of natural waters, but that other halogenated lipophilic material is also formed.« less

  15. The prevalence of Escherichia coli O157:H7 fecal shedding in feedlot pens is affected by the water-to-cattle ratio: A randomized controlled trial.

    PubMed

    Beauvais, Wendy; Gart, Elena V; Bean, Melissa; Blanco, Anthony; Wilsey, Jennifer; McWhinney, Kallie; Bryan, Laura; Krath, Mary; Yang, Ching-Yuan; Manriquez Alvarez, Diego; Paudyal, Sushil; Bryan, Kelsey; Stewart, Samantha; Cook, Peter W; Lahodny, Glenn; Baumgarten, Karina; Gautam, Raju; Nightingale, Kendra; Lawhon, Sara D; Pinedo, Pablo; Ivanek, Renata

    2018-01-01

    Escherichia coli O157:H7 fecal shedding in feedlot cattle is common and is a public health concern due to the risk of foodborne transmission that can result in severe, or even fatal, disease in people. Despite a large body of research, few practical and cost-effective farm-level interventions have been identified. In this study, a randomized controlled trial was conducted to assess the effect of reducing the level of water in automatically refilling water-troughs on fecal shedding of E. coli O157:H7 in feedlot cattle. Pens in a feedlot in the Texas Panhandle were randomly allocated as control (total number: 17) or intervention (total number: 18) pens. Fecal samples (2,759 in total) were collected both at baseline and three weeks after the intervention, and tested for the presence of E. coli O157:H7 using immunomagnetic bead separation and selective culture. There was a strong statistical association between sampling date and the likelihood of a fecal sample testing positive for E. coli O157:H7. Pen was also a strong predictor of fecal prevalence. Despite accounting for this high level of clustering, a statistically significant association between reduced water levels in the trough and increased prevalence of E. coli O157:H7 in the feces was observed (Odds Ratio = 1.6; 95% Confidence Interval: 1.2-2.0; Likelihood Ratio Test: p = 0.02). This is the first time that such an association has been reported, and suggests that increasing water-trough levels may be effective in reducing shedding of E. coli O157:H7 in cattle feces, although further work would be needed to test this hypothesis. Controlling E. coli O157:H7 fecal shedding at the pre-harvest level may lead to a reduced burden of human foodborne illness attributed to this pathogen in beef.

  16. The prevalence of Escherichia coli O157:H7 fecal shedding in feedlot pens is affected by the water-to-cattle ratio: A randomized controlled trial

    PubMed Central

    Gart, Elena V.; Bean, Melissa; Blanco, Anthony; Wilsey, Jennifer; McWhinney, Kallie; Bryan, Laura; Krath, Mary; Yang, Ching-Yuan; Manriquez Alvarez, Diego; Paudyal, Sushil; Bryan, Kelsey; Stewart, Samantha; Cook, Peter W.; Lahodny, Glenn; Baumgarten, Karina; Gautam, Raju; Nightingale, Kendra; Lawhon, Sara D.; Pinedo, Pablo; Ivanek, Renata

    2018-01-01

    Escherichia coli O157:H7 fecal shedding in feedlot cattle is common and is a public health concern due to the risk of foodborne transmission that can result in severe, or even fatal, disease in people. Despite a large body of research, few practical and cost-effective farm-level interventions have been identified. In this study, a randomized controlled trial was conducted to assess the effect of reducing the level of water in automatically refilling water-troughs on fecal shedding of E. coli O157:H7 in feedlot cattle. Pens in a feedlot in the Texas Panhandle were randomly allocated as control (total number: 17) or intervention (total number: 18) pens. Fecal samples (2,759 in total) were collected both at baseline and three weeks after the intervention, and tested for the presence of E. coli O157:H7 using immunomagnetic bead separation and selective culture. There was a strong statistical association between sampling date and the likelihood of a fecal sample testing positive for E. coli O157:H7. Pen was also a strong predictor of fecal prevalence. Despite accounting for this high level of clustering, a statistically significant association between reduced water levels in the trough and increased prevalence of E. coli O157:H7 in the feces was observed (Odds Ratio = 1.6; 95% Confidence Interval: 1.2–2.0; Likelihood Ratio Test: p = 0.02). This is the first time that such an association has been reported, and suggests that increasing water-trough levels may be effective in reducing shedding of E. coli O157:H7 in cattle feces, although further work would be needed to test this hypothesis. Controlling E. coli O157:H7 fecal shedding at the pre-harvest level may lead to a reduced burden of human foodborne illness attributed to this pathogen in beef. PMID:29414986

  17. Trihalomethanes in public water supplies and risk of stillbirth.

    PubMed

    Dodds, Linda; King, Will; Allen, Alexander C; Armson, B Anthony; Fell, Deshayne B; Nimrod, Carl

    2004-03-01

    The chlorine used to disinfect public drinking water supplies reacts with naturally occurring organic matter to form a number of chemical byproducts. Recent studies have implicated exposure to chlorination byproducts in drinking water, trihalomethanes (THMs), in particular, with intrauterine death. We conducted a population-based case-control study in Nova Scotia and Eastern Ontario, Canada, to examine the effect of exposure to THMs on stillbirth risk. Cases were women who had a stillborn infant, and controls were a random sample of women with live births. Subjects were interviewed, and women with a public water source provided a residential water sample. Risks were examined according to residential THM level in tap water and to a total exposure metric incorporating tap water ingestion, showering, and bathing. We enrolled 112 stillbirth cases and 398 live birth controls. Women with a residential total THM level of 80 or more microg/L had twice the risk of a stillbirth compared with women with no exposure to THMs (adjusted odds ratio [OR] = 2.2; 95% confidence interval [CI] = 1.1-4.4). The highest quintile of total THM exposure using the total exposure metric was associated with an adjusted odds ratio of 2.4 (95% CI = 1.2-4.6) compared with women not exposed to THMs. Similar results were seen for specific THM compounds. A monotonic dose-response relationship was not seen. Our results provide evidence for an increased risk of stillbirth associated with exposure to chlorination byproducts through ingestion and showering and bathing, although there was not a clear dose-response relationship.

  18. Temperature and volumetric water content petrophysical relationships in municipal solid waste for the interpretation of bulk electrical resistivity data

    NASA Astrophysics Data System (ADS)

    Pilawski, Tamara; Dumont, Gaël; Nguyen, Frédéric

    2015-04-01

    Landfills pose major environmental issues including long-term methane emissions, and local pollution of soil and aquifers but can also be seen as potential energy resources and mining opportunities. Water content in landfills determine whether solid fractions can be separated and recycled, and controls the existence and efficiency of natural or enhanced biodegradation. Geophysical techniques, such as electrical and electromagnetic methods have proven successful in the detection and qualitative investigation of sanitary landfills. However, their interpretation in terms of quantitative water content estimates makes it more challenging due to the influence of parameters such as temperature, compaction, waste composition or pore fluid. To improve the confidence given to bulk electrical resistivity data and to their interpretation, we established temperature and volumetric water content petrophysical relationships that we tested on field and laboratory electrical resistivity measurements. We carried out two laboratory experiments on leachates and waste samples from a landfill located in Mont-Saint-Guibert, Belgium. We determined a first relationship between temperature and electrical resistivity with pure and diluted leachates by progressively increasing the temperature from 5°C to 65°C, and then cooling down to 5°C. The second relationship was obtained by measuring electrical resistivity on waste samples of different volumetric water contents. First, we used the correlations obtained from the experiments to compare electrical resistivity measurements performed in a landfill borehole and on reworked waste samples excavated at different depths. Electrical resistivities were measured every 20cm with an electromagnetic logging device (EM39) while a temperature profile was acquired with optic fibres. Waste samples were excavated every 2m in the same borehole. We filled experimental columns with these samples and measured electrical resistivities at laboratory temperature. We made corrections according to the temperature profile and to volumetric water contents obtained previously on undisturbed samples. Corrected values tended to be superimposed on those obtained in the field. Then, we calculated the water content of the different reworked waste samples using the correlation between volumetric water content correlation and electrical resistivity and we compared this value to the one measured at the laboratory. Both values were correlated satisfactorily. In conclusion, we show that bulk electrical resistivity measurements are very promising to quantify water content in landfills if temperature can be estimated independently. In future applications, electrical resistivity tomography coupled with distributed temperature sensing could give important estimates of water content of the waste and thus helping in dealing with problematics such as boosting biodegradation and stabilization of the waste, reducing risks of soil and aquifers pollution, landfill mining, and controlled production of methane.

  19. Comparison of microbial community shifts in two parallel multi-step drinking water treatment processes.

    PubMed

    Xu, Jiajiong; Tang, Wei; Ma, Jun; Wang, Hong

    2017-07-01

    Drinking water treatment processes remove undesirable chemicals and microorganisms from source water, which is vital to public health protection. The purpose of this study was to investigate the effects of treatment processes and configuration on the microbiome by comparing microbial community shifts in two series of different treatment processes operated in parallel within a full-scale drinking water treatment plant (DWTP) in Southeast China. Illumina sequencing of 16S rRNA genes of water samples demonstrated little effect of coagulation/sedimentation and pre-oxidation steps on bacterial communities, in contrast to dramatic and concurrent microbial community shifts during ozonation, granular activated carbon treatment, sand filtration, and disinfection for both series. A large number of unique operational taxonomic units (OTUs) at these four treatment steps further illustrated their strong shaping power towards the drinking water microbial communities. Interestingly, multidimensional scaling analysis revealed tight clustering of biofilm samples collected from different treatment steps, with Nitrospira, the nitrite-oxidizing bacteria, noted at higher relative abundances in biofilm compared to water samples. Overall, this study provides a snapshot of step-to-step microbial evolvement in multi-step drinking water treatment systems, and the results provide insight to control and manipulation of the drinking water microbiome via optimization of DWTP design and operation.

  20. Water quality of the Lexington Reservoir, Santa Clara County, California, 1978-80

    USGS Publications Warehouse

    Iwatsubo, R.T.; Sylvester, M.A.; Gloege, I.S.

    1988-01-01

    Analysis of water samples from Lexington Reservoir and Los Gatos Creek upstream from the reservoir from June 1978 through September 1980 showed that water generally met water-quality objectives identified by California Regional Water Quality Control Board, San Francisco Bay Region. Water-temperature profiles show that Lexington Reservoir is a warm monomictic lake. During summer, dissolved-oxygen concentrations generally were not reduced below 5.0 mg/L in the hyplimnion; only once during the study did bottom waters become anoxic. Water transparency decreased with depth. The euphotic zone ranged from 1.0 to 5.4 m, depending on suspended solids and algae, and was greater in summer than in spring. Calcium and bicarbonate were dominant ions at all stations except during spring, following the rainy season, when waters were a mixed cation bicarbonate type. Nitrogen concentrations were greater in samples from reservoir stations than in those from Los Gatos Creek, with most of the nitrogen in ammonia and organic forms. The amount of dissolved nitrate appeared to be related to phytoplankton abundance. Phosphorus and trace-element concentrations were low at all stations. Estimates of net primary productivity and Carlson 's trophic-state index, based on chlorophyll-a concentrations, indicated that reservoir classification ranges from oligotrophic to mesotrophic. Blue-green algae generally were predominant in reservoir samples. (USGS)

  1. Mercury Release from the Rathburn Mine, Petray Mine, and Bear Valley Saline Springs, Colusa County, California 2004-2006

    USGS Publications Warehouse

    Slowey, Aaron J.; Rytuba, James J.

    2008-01-01

    This report summarizes data obtained from field sampling of mine tailings and waste rock at the Rathburn and Petray Mines that was initiated in July 17, 2001 and water and sediment in regional springs and tributaries that drain from the mine area into Bear Creek on December 14, 2004 and February 16 and May 27, 2005. Although it was initially assumed that the mines were the cause of elevated levels of monomethyl Hg measured by the Central Regional Water Quality Control Board in tributaries near their confluence with Bear Creek (Foe and others, unpublished results), it became apparent during this study that ground water springs were also potential sources of Hg. In addition to sampling of springs in May 2005, saline ground water seepage along an unnamed fault on the west side of Bear Valley was sampled on December 13-14, 2006. We did not sample water or sediment in Bear Creek itself during this study. Our results permit a preliminary assessment of mining and natural sources of Hg and associated chemical constituents that could elevate levels of monomethyl Hg in Bear Creek.

  2. Reconnaissance of Organic Wastewater Compounds at a Concentrated Swine Feeding Operation in the North Carolina Coastal Plain, 2008

    USGS Publications Warehouse

    Harden, Stephen L.

    2009-01-01

    Water-quality and hydrologic data were collected during 2008 to examine the occurrence of organic wastewater compounds at a concentrated swine feeding operation located in the North Carolina Coastal Plain. Continuous groundwater level and stream-stage data were collected at one monitoring well and one stream site, respectively, throughout 2008. One round of environmental and quality-control samples was collected in September 2008 following a period of below-normal precipitation and when swine waste was not being applied to the spray fields. Samples were collected at one lagoon site, seven shallow groundwater sites, and one surface-water site for analysis of 111 organic wastewater compounds, including household, industrial, and agricultural-use compounds, sterols, pharmaceutical compounds, hormones, and antibiotics. Analytical data for environmental samples collected during the study provide preliminary information on the occurrence of organic wastewater compounds in the lagoon-waste source material, groundwater beneath fields that receive spray applications of the lagoon wastes, and surface water in the tributary adjacent to the site. Overall, 28 organic wastewater compounds were detected in the collected samples, including 11 household, industrial, and agricultural-use compounds; 3 sterols; 2 pharmaceutical compounds; 5 hormones; and 7 antibiotics. The lagoon sample had the greatest number (20) and highest concentrations of compounds compared to groundwater and surface-water samples. The antibiotic lincomycin had the maximum detected concentration (393 micrograms per liter) in the lagoon sample. Of the 11 compounds identified in the groundwater and surface-water samples, all with reported concentrations less than 1 microgram per liter, only lincomycin identified in groundwater at 1 well and 3-methyl-1H-indole and indole identified in surface water at 1 site also were identified in the lagoon waste material.

  3. Diversity of Salmonella serovars in feedyard and nonfeedyard playas of the Southern High Plains in the summer and winter.

    PubMed

    Purdy, Charles W; Straus, David C; Clark, R Nolan

    2004-01-01

    To compare Salmonella isolates cultured from feedyard and nonfeedyard (control) playas (ie, temporary shallow lakes) of the Southern High Plains. Water and muck (sediment) samples were obtained from 7 feedyard playas and 3 nonfeedyard playas in the winter and summer. Each water and muck sample was enriched with sulfur-brilliant-green broth and incubated in a shaker at 37 degrees C for 24 hours. A sample (100 mL) of the incubated bacterial-enriched broth was then mixed with 100 mL of fresh sulfur-brilliant-green enrichment broth and incubated in a shaker at 37 degrees C for 24 hours. After the second incubation, a swab sample was streaked on differential media. Suspect Salmonella isolates were further identified by use of biochemical tests, and Salmonella isolates were confirmed and serovar determinations made. Salmonella isolates were not recovered from the 3 control playas. Seven Salmonella enterica serovars were isolated from 5 of 7 feedyard playas in the summer, and 13 S. enterica serovars were isolated from 7 of 7 feedyard playas in the winter. In the summer, 296 isolates were cultured, and 47 were Salmonella organisms. In the winter, 288 isolates were cultured, and 171 were Salmonella organisms. Results indicated that feedyard playas are frequently contaminated with many Salmonella serovars. These pathogens should be considered whenever feedyard managers contemplate the use of water from these playas. Water from feedyard playas should not be used to cool cattle in the summer or for dust abatement.

  4. Integrated Cryptosporidium Assay To Determine Oocyst Density, Infectivity, and Genotype for Risk Assessment of Source and Reuse Water

    PubMed Central

    King, Brendon; Fanok, Stella; Phillips, Renae; Swaffer, Brooke

    2015-01-01

    Cryptosporidium continues to be problematic for the water industry, with risk assessments often indicating that treatment barriers may fail under extreme conditions. However, risk analyses have historically used oocyst densities and not considered either oocyst infectivity or species/genotype, which can result in an overestimation of risk if the oocysts are not human infective. We describe an integrated assay for determining oocyst density, infectivity, and genotype from a single-sample concentrate, an important advance that overcomes the need for processing multiple-grab samples or splitting sample concentrates for separate analyses. The assay incorporates an oocyst recovery control and is compatible with standard primary concentration techniques. Oocysts were purified from primary concentrates using immunomagnetic separation prior to processing by an infectivity assay. Plate-based cell culture was used to detect infectious foci, with a monolayer washing protocol developed to allow recovery and enumeration of oocysts. A simple DNA extraction protocol was developed to allow typing of any wells containing infectious Cryptosporidium. Water samples from a variety of source water and wastewater matrices, including a semirural catchment, wastewater, an aquifer recharge site, and storm water, were analyzed using the assay. Results demonstrate that the assay can reliably determine oocyst densities, infectivity, and genotype from single-grab samples for a variety of water matrices and emphasize the varying nature of Cryptosporidium risk extant throughout source waters and wastewaters. This assay should therefore enable a more comprehensive understanding of Cryptosporidium risk for different water sources, assisting in the selection of appropriate risk mitigation measures. PMID:25769833

  5. Integrated cryptosporidium assay to determine oocyst density, infectivity, and genotype for risk assessment of source and reuse water.

    PubMed

    King, Brendon; Fanok, Stella; Phillips, Renae; Swaffer, Brooke; Monis, Paul

    2015-05-15

    Cryptosporidium continues to be problematic for the water industry, with risk assessments often indicating that treatment barriers may fail under extreme conditions. However, risk analyses have historically used oocyst densities and not considered either oocyst infectivity or species/genotype, which can result in an overestimation of risk if the oocysts are not human infective. We describe an integrated assay for determining oocyst density, infectivity, and genotype from a single-sample concentrate, an important advance that overcomes the need for processing multiple-grab samples or splitting sample concentrates for separate analyses. The assay incorporates an oocyst recovery control and is compatible with standard primary concentration techniques. Oocysts were purified from primary concentrates using immunomagnetic separation prior to processing by an infectivity assay. Plate-based cell culture was used to detect infectious foci, with a monolayer washing protocol developed to allow recovery and enumeration of oocysts. A simple DNA extraction protocol was developed to allow typing of any wells containing infectious Cryptosporidium. Water samples from a variety of source water and wastewater matrices, including a semirural catchment, wastewater, an aquifer recharge site, and storm water, were analyzed using the assay. Results demonstrate that the assay can reliably determine oocyst densities, infectivity, and genotype from single-grab samples for a variety of water matrices and emphasize the varying nature of Cryptosporidium risk extant throughout source waters and wastewaters. This assay should therefore enable a more comprehensive understanding of Cryptosporidium risk for different water sources, assisting in the selection of appropriate risk mitigation measures. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

    PubMed Central

    States, S J; Conley, L F; Kuchta, J M; Oleck, B M; Lipovich, M J; Wolford, R S; Wadowsky, R M; McNamara, A M; Sykora, J L; Keleti, G

    1987-01-01

    Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs. PMID:3606101

  7. Preimpoundment water quality of the Wild Rice River, Norman County, Minnesota

    USGS Publications Warehouse

    Tornes, L.H.

    1980-01-01

    Water samples have been collected at two sites on the Wild Rice River since September 1974 to establish baseline water-quality characteristics before construction of a reservoir for recreation and flood control near Twin Valley, Minn. A decline in water quality between the sites is shown by mean total phosphorus concentrations, which increase from 0.06 to 0.10 milligram per liter downstream, and mean turbidity, which increases from 12 to 24 units downstream. Phosphorus and ammonia concentrations, as high as 0.31 and 2.7 milligrams per liter, respectively, could be the result of domestic waste input to the river upstream from Hendrum. Biochemical oxygen demand concentrations were significantly higher during spring runoff than during the rest of the year. Four out of 90 bacteria samples taken at Twin Valley indicate the presence of human fecal material, though bacteria densities do not exceed recommendations of the U.S. Environmental Protection Agency for public-water supplies. The dominace of organic-pollution tolerant phytoplankton in 49 out of 78 samples also indicates degradation of the river quality at Twin Valley. Nutrient concentrations at Twin Valley have no apparent effect on phytoplankton concentrations. None of the consitituents sampled were found to exceed recommended concentrations for public-water supplies.

  8. Evaluation of formation water chemistry and scale prediction: Bakken Shale

    DOE PAGES

    Thyne, Geoffrey; Brady, Patrick

    2016-10-24

    Determination of in situ formation water chemistry is an essential component of reservoir management. This study details the use of thermodynamic computer models to calculate reservoir pH and restore produced water analyses for prediction of scale formation. Bakken produced water samples were restored to formation conditions and calculations of scale formation performed. In situ pH is controlled by feldspar-clay equilibria. Calcite scale is readily formed due to changes in pH during pressure drop from in situ to surface conditions. The formation of anhydrite and halite scale, which has been observed, was predicted only for the most saline samples. Finally, inmore » addition, the formation of anhydrite and/or halite may be related to the localized conditions of increased salinity as water is partitioned into the gas phase during production.« less

  9. Determination of fragrances at ng/L levels using CLSA and GC/MS detection.

    PubMed

    Mitjans, D; Ventura, F

    2005-01-01

    Polycyclic and nitro musks and two fragrances (Acetyl cedrene and Amberonne) have been determined and quantified in influent and effluent waste water, river water and tap water samples from different European countries by closed loop stripping analysis (CLSA) as a method of preconcentration and GC/MS operating in the SIM mode. Limits of detection; precision expressed as repeatability and reproducibility relative standard deviations of the method; matrix effects and the estimation of the uncertainty have been evaluated. All samples contained different musks at ng/l levels being the polycyclic musks Galaxolide and Tonalide and both fragrances, Amberonne and Acetyl cedrene the most abundant. Removal of these main compounds is achieved partially in all waste water treatment plants studied. These results suggest the importance of studying and controlling the presence of these ubiquitous environmental compounds in water systems.

  10. Contamination with bacterial zoonotic pathogen genes in U.S. streams influenced by varying types of animal agriculture.

    PubMed

    Haack, Sheridan K; Duris, Joseph W; Kolpin, Dana W; Focazio, Michael J; Meyer, Michael T; Johnson, Heather E; Oster, Ryan J; Foreman, William T

    2016-09-01

    Animal waste, stream water, and streambed sediment from 19 small (<32km(2)) watersheds in 12U.S. states having either no major animal agriculture (control, n=4), or predominantly beef (n=4), dairy (n=3), swine (n=5), or poultry (n=3) were tested for: 1) cholesterol, coprostanol, estrone, and fecal indicator bacteria (FIB) concentrations, and 2) shiga-toxin producing and enterotoxigenic Escherichia coli, Salmonella, Campylobacter, and pathogenic and vancomycin-resistant enterococci by polymerase chain reaction (PCR) on enrichments, and/or direct quantitative PCR. Pathogen genes were most frequently detected in dairy wastes, followed by beef, swine and poultry wastes in that order; there was only one detection of an animal-source-specific pathogen gene (stx1) in any water or sediment sample in any control watershed. Post-rainfall pathogen gene numbers in stream water were significantly correlated with FIB, cholesterol and coprostanol concentrations, and were most highly correlated in dairy watershed samples collected from 3 different states. Although collected across multiple states and ecoregions, animal-waste gene profiles were distinctive via discriminant analysis. Stream water gene profiles could also be discriminated by the watershed animal type. Although pathogen genes were not abundant in stream water or streambed samples, PCR on enrichments indicated that many genes were from viable organisms, including several (shiga-toxin producing or enterotoxigenic E. coli, Salmonella, vancomycin-resistant enterococci) that could potentially affect either human or animal health. Pathogen gene numbers and types in stream water samples were influenced most by animal type, by local factors such as whether animals had stream access, and by the amount of local rainfall, and not by studied watershed soil or physical characteristics. Our results indicated that stream water in small agricultural U.S. watersheds was susceptible to pathogen gene inputs under typical agricultural practices and environmental conditions. Pathogen gene profiles may offer the potential to address both source of, and risks associated with, fecal pollution. Published by Elsevier B.V.

  11. Uranium and radon in private bedrock well water in Maine: geospatial analysis at two scales

    USGS Publications Warehouse

    Yang, Qiang; Smitherman, Paul; Hess, C.T.; Culbertson, Charles W.; Marvinney, Robert G.; Zheng, Yan

    2014-01-01

    In greater Augusta of central Maine, 53 out of 1093 (4.8%) private bedrock well water samples from 1534 km2 contained [U] >30 μg/L, the U.S. Environmental Protection Agency’s (EPA) Maximum Contaminant Level (MCL) for drinking water; and 226 out of 786 (29%) samples from 1135 km2 showed [Rn] >4,000 pCi/L (148 Bq/L), the U.S. EPA’s Alternative MCL. Groundwater pH, calcite dissolution and redox condition are factors controlling the distribution of groundwater U but not Rn due to their divergent chemical and hydrological properties. Groundwater U is associated with incompatible elements (S, As, Mo, F, and Cs) in water samples within granitic intrusions. Elevated [U] and [Rn] are located within 5–10 km distance of granitic intrusions but do not show correlations with metamorphism at intermediate scales (100−101 km). This spatial association is confirmed by a high-density sampling (n = 331, 5–40 samples per km2) at local scales (≤10–1 km) and the statewide sampling (n = 5857, 1 sample per 16 km2) at regional scales (102–103 km). Wells located within 5 km of granitic intrusions are at risk of containing high levels of [U] and [Rn]. Approximately 48 800–63 900 and 324 000 people in Maine are estimated at risk of exposure to U (>30 μg/L) and Rn (>4000 pCi/L) in well water, respectively.

  12. Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling.

    PubMed

    Söderström, Hanna; Lindberg, Richard H; Fick, Jerker

    2009-01-16

    Although polar organic contaminants (POCs) such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and field of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs.

  13. Adjustment of pesticide concentrations for temporal changes in analytical recovery, 1992–2010

    USGS Publications Warehouse

    Martin, Jeffrey D.; Eberle, Michael

    2011-01-01

    Recovery is the proportion of a target analyte that is quantified by an analytical method and is a primary indicator of the analytical bias of a measurement. Recovery is measured by analysis of quality-control (QC) water samples that have known amounts of target analytes added ("spiked" QC samples). For pesticides, recovery is the measured amount of pesticide in the spiked QC sample expressed as a percentage of the amount spiked, ideally 100 percent. Temporal changes in recovery have the potential to adversely affect time-trend analysis of pesticide concentrations by introducing trends in apparent environmental concentrations that are caused by trends in performance of the analytical method rather than by trends in pesticide use or other environmental conditions. This report presents data and models related to the recovery of 44 pesticides and 8 pesticide degradates (hereafter referred to as "pesticides") that were selected for a national analysis of time trends in pesticide concentrations in streams. Water samples were analyzed for these pesticides from 1992 through 2010 by gas chromatography/mass spectrometry. Recovery was measured by analysis of pesticide-spiked QC water samples. Models of recovery, based on robust, locally weighted scatterplot smooths (lowess smooths) of matrix spikes, were developed separately for groundwater and stream-water samples. The models of recovery can be used to adjust concentrations of pesticides measured in groundwater or stream-water samples to 100 percent recovery to compensate for temporal changes in the performance (bias) of the analytical method.

  14. Excretion of arsenic (As) in urine of children, 7-11 years, exposed to elevated levels of As in the city water supply in Hermosillo, Sonora, México.

    PubMed

    Wyatt, C J; Lopez Quiroga, V; Olivas Acosta, R T; Olivia Méndez, R

    1998-07-01

    Arsenic (As) is a common element in the environment with many industrial uses, but it also can be a contaminant in drinking water and present serious health concerns. Earlier studies on the quality of drinking water in the city of Hermosillo, Sonora, México, showed high levels of As (> 0.05 ppm) in water from wells located in the northern part of the city. Additionally a high positive correlation between the levels of Fluoride (F) and As in the same wells was found. Therefore, the objective of this study was to determine the excretion of As in children, 7-11 years of age, that had been exposed to elevated levels of As in their drinking water. Twenty-four-hour urine samples and a water sample taken directly in the home were collected from school age children living in two different areas with known high levels of As in their drinking water. A control group with normal levels of As in their water was also included. As was determined by an atomic absorption-hydride generator, verified with the use of NBS certified standards (SRM 1643a and SRM 2670). None of the water samples exceeded the limit established for drinking water; however, there was a significant difference between the intake of As and the As in drinking water among the three areas of the study. Average As in water was 0.009 +/- 0.002 and 0.030 +/- 0.011 micrograms/ml between the control and high areas. Intake (in micrograms/day) was 15 +/- 3 and 54 +/- 18. In the group consuming water with high levels of As, 65% of the children exceeded the recommended dose of < 1 micrograms/kg/day (EPA, 1988). Several children in this study also had high levels of As in their urine. Even though As levels in the drinking water are within the norms, it appears that children exposed to high levels of As in their drinking water may have a health risk.

  15. A community randomised controlled trial evaluating a home-based environmental intervention package of improved stoves, solar water disinfection and kitchen sinks in rural Peru: rationale, trial design and baseline findings.

    PubMed

    Hartinger, S M; Lanata, C F; Hattendorf, J; Gil, A I; Verastegui, H; Ochoa, T; Mäusezahl, D

    2011-11-01

    Pneumonia and diarrhoea are leading causes of death in children. There is a need to develop effective interventions. We present the design and baseline findings of a community-randomised controlled trial in rural Peru to evaluate the health impact of an Integrated Home-based Intervention Package in children aged 6 to 35 months. We randomised 51 communities. The intervention was developed through a community-participatory approach prior to the trial. They comprised the construction of improved stoves and kitchen sinks, the promotion of hand washing, and solar drinking water disinfection (SODIS). To reduce the potential impact of non-blinding bias, a psychomotor stimulation intervention was implemented in the control arm. The baseline survey included anthropometric and socio-economic characteristics. In a sub-sample we determined the level of faecal contamination of drinking water, hands and kitchen utensils and the prevalence of diarrhoegenic Escherichia coli in stool specimen. We enrolled 534 children. At baseline all households used open fires and 77% had access to piped water supplies. E. coli was found in drinking water in 68% and 64% of the intervention and control households. Diarrhoegenic E. coli strains were isolated from 45/139 stool samples. The proportion of stunted children was 54%. Randomization resulted in comparable study arms. Recently, several critical reviews raised major concerns on the reliability of open health intervention trials, because of uncertain sustainability and non-blinding bias. In this regard, the presented trial featuring objective outcome measures, a simultaneous intervention in the control communities and a 12-month follow up period will provide valuable evidence. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Management of Chronic Periodontitis Using Subgingival Irrigation of Ozonized Water: A Clinical and Microbiological Study

    PubMed Central

    Mathew, Jayan Jacob; Ambooken, Majo; Kachappilly, Arun Jose; PK, Ajithkumar; Johny, Thomas; VK, Linith; Samuel, Anju

    2015-01-01

    Introduction Adjunctive use of professional subgingival irrigation with scaling and root planing (SRP) has been found to be beneficial in eradicating the residual microorganisms in the pocket. Objective To evaluate the effect of ozonized water subgingival irrigation on microbiologic parameters and clinical parameters namely Gingival index, probing pocket depth, and clinical attachment level. Materials and Methods Thirty chronic periodontitis patients with probing pocket depth ≥6mm on at least one tooth on contra lateral sides of opposite arches were included in the study. The test sites were subjected to ozonized water subgingival irrigation with subgingival irrigation device fitted with a modified subgingival tip. Control sites were subjected to scaling and root planing only. The following clinical parameters were recorded initially and after 4 weeks at the test sites and control sites. Plaque Index, Gingival Index, probing pocket depth, clinical attachment level. Microbiologic sampling was done for the test at the baseline, after scaling, immediately after ozonized water subgingival irrigation and after 4 weeks. In control sites microbiologic sampling was done at the baseline, after scaling and after 4 weeks. The following observations were made after 4 weeks. The results were statistically analysed using independent t-test and paired t-test. Result Test sites showed a greater reduction in pocket depth and gain in clinical attachment compared to control sites. The total anaerobic counts were significantly reduced by ozonized water subgingival irrigation along with SRP compared to SRP alone. Conclusion Ozonized water subgingival irrigation can improve the clinical and microbiological parameters in patients with chronic periodontitis when used as an adjunct to scaling and root planing. PMID:26436042

  17. Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base.

    PubMed

    Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa

    2017-01-01

    Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups.

  18. Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base

    PubMed Central

    Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa

    2017-01-01

    Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups. PMID:29184635

  19. Dissolved oxygen saturation controls PAH biodegradation in freshwater estuary sediments.

    PubMed

    Boyd, T J; Montgomery, M T; Steele, J K; Pohlman, J W; Reatherford, S R; Spargo, B J; Smith, D C

    2005-02-01

    Polycyclic aromatic hydrocarbons (PAHs) are common contaminants in terrestrial and aquatic environments and can represent a significant constituent of the carbon pool in coastal sediments. We report here the results of an 18-month seasonal study of PAH biodegradation and heterotrophic bacterial production and their controlling biogeochemical factors from 186 sediment samples taken in a tidally influenced freshwater estuary. For each sampling event, measurements were averaged from 25-45 stations covering approximately 250 km(2). There was a clear relationship between bacterial production and ambient temperature, but none between production and bottom water dissolved oxygen (DO) % saturation or PAH concentrations. In contrast with other studies, we found no effect of temperature on the biodegradation of naphthalene, phenanthrene, or fluoranthene. PAH mineralization correlated with bottom water DO saturation above 70% (r(2) > 0.99). These results suggest that the proportional utilization of PAH carbon to natural organic carbon is as much as three orders of magnitude higher during cooler months, when water temperatures are lower and DO % saturation is higher. Infusion of cooler, well-oxygenated water to the water column overlying contaminated sediments during the summer months may stimulate PAH metabolism preferentially over non-PAH organic matter.

  20. Community-acquired Legionnaires' Disease in a Newly Constructed Apartment Building.

    PubMed

    Ryu, Sukhyun; Yang, Kyungho; Chun, Byung Chul

    2017-07-01

    Legionnaires' disease (LD) is a severe type of pneumonia caused by inhalation of aerosols contaminated with Legionella . On September 22, 2016, a single case of LD was reported from a newly built apartment building in Gyeonggi province. This article describes an epidemiologic investigation of LD and identification of the possible source of infection. To identify the source of LD, we interviewed the patient's husband using a questionnaire based on the Legionella management guidelines from the Korea Centers for Disease Control and Prevention. Water samples from the site were collected and analyzed. An epidemiological investigation of the residents and visitors in the apartment building was conducted for 14 days before the index patient's symptoms first appeared to 14 days after the implementation of environmental control measures. Legionella pneumophila serogroup 1 was isolated from the heated-water samples from the patient's residence and the basement of the apartment complex. Thirty-two suspected cases were reported from the apartment building during the surveillance period, yet all were confirmed negative based on urinary antigen tests. The likely source of infection was the building's potable water, particularly heated water. Further study of effective monitoring systems in heated potable water should be considered.

  1. Space Station CMIF extended duration metabolic control test

    NASA Technical Reports Server (NTRS)

    Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathryn Y.; Wieland, Paul O.

    1989-01-01

    The Space Station Extended Duration Metabolic Control Test (EMCT) was conducted at the MSFC Core Module Integration Facility. The primary objective of the EMCT was to gather performance data from a partially-closed regenerative Environmental Control and Life Support (ECLS) system functioning under steady-state conditions. Included is a description of the EMCT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements of water and gas samples taken during the test. A comparison of the physical, chemical, and microbiological methods used in the post test laboratory analyses of the water samples is included. The preprototype ECLS hardware used in the test, providing an overall process description and theory of operation for each hardware item. Analytical results pertaining to a system level mass balance and selected system power estimates are also included.

  2. Rainfall, Streamflow, and Water-Quality Data During Stormwater Monitoring, Halawa Stream Drainage Basin, Oahu, Hawaii, July 1, 2004 to June 30, 2005

    USGS Publications Warehouse

    Young, Stacie T.M.; Ball, Marcael T.J.

    2005-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at two stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2004 and June 30, 2005. A total of 15 samples was collected over three storms during July 1, 2004 to June 30, 2005. In general, an attempt was made to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. However, all three storms were partially sampled because either not all stations were sampled or not all composite samples were collected. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Chromium and nickel were added to the analysis starting October 1, 2004. Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.

  3. Relation of Chlorofluorocarbon Ground-Water Age Dates to Water Quality in Aquifers of West Virginia

    USGS Publications Warehouse

    ,; Kurt, J.; Kozar, Mark D.

    2007-01-01

    The average apparent age of ground water in fractured-bedrock aquifers in West Virginia was determined using chlorofluorocarbon (CFC) dating methods. Since the introduction of CFC gases as refrigerants in the late 1930s, atmospheric concentrations have increased until production ceased in the mid-1990s. CFC dating methods are based on production records that date to the early 1940s, and the preservation of atmospheric CFC concentrations in ground water at the time of recharge. As part of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) and Ambient Ground-Water Monitoring Network (AGN) programs in West Virginia from 1997 to 2005, 80 samples from the Appalachian Plateaus Physiographic Province, 27 samples from the Valley and Ridge Physiographic Province, and 5 samples from the Ohio River alluvial aquifers were collected to estimate ground-water ages in aquifers of West Virginia. Apparent CFC ages of water samples from West Virginia aquifers ranged from 5.8 to 56 years. In the Appalachian Plateaus, topographically driven ground-water flow is evident from apparent ages of water samples from hilltop, hillside, and valley settings (median apparent ages of 12, 14, and 25 years, respectively). Topographic setting was the only factor that was found to be related to apparent ground-water age in the Plateaus at the scale of this study. Similar relations were not found in Valley and Ridge aquifers, indicating that other factors such as bedding or geologic structure may serve larger roles in controlling ground-water flow in that physiographic province. Degradation of CFCs was common in samples collected from methanogenic/anoxic aquifers in the Appalachian Plateaus and suboxic to anoxic aquifers in the Valley and Ridge. CFC contamination was most common in Ohio River alluvial aquifers and carbonate units of the Valley and Ridge, indicating that these highly transmissive surficial aquifers are the most vulnerable to water-quality degradation and may contain wastewater from domestic or industrial sources with CFC concentrations greater than modern atmospheric levels. However, based on a lack of detections of the volatile organic compounds analyzed for in most of the water samples collected for this and similar USGS investigations, ground-water resources of West Virginia used for public and private consumption do not appear to be routinely affected by anthropogenic activities despite their young apparent age.

  4. Preparation and validation of gross alpha/beta samples used in EML`s quality assessment program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpitta, S.C.

    1997-10-01

    A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory`s (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ({sup 241}Am, {sup 230}Th and {sup 238}Pu) andmore » beta ({sup 90}Sr/{sup 90}Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared.« less

  5. Analytical results from ground-water sampling using a direct-push technique at the Dover National Test Site, Dover Air Force Base, Delaware, June-July 2001

    USGS Publications Warehouse

    Guertal, William R.; Stewart, Marie; Barbaro, Jeffrey R.; McHale, Timthoy J.

    2004-01-01

    A joint study by the Dover National Test Site and the U.S. Geological Survey was conducted from June 27 through July 18, 2001 to determine the spatial distribution of the gasoline oxygenate additive methyl tert-butyl ether and selected water-quality constituents in the surficial aquifer underlying the Dover National Test Site at Dover Air Force Base, Delaware. The study was conducted to support a planned enhanced bio-remediation demonstration and to assist the Dover National Test Site in identifying possible locations for future methyl tert-butyl ether remediation demonstrations. This report presents the analytical results from ground-water samples collected during the direct-push ground-water sampling study. A direct-push drill rig was used to quickly collect 115 ground-water samples over a large area at varying depths. The ground-water samples and associated quality-control samples were analyzed for volatile organic compounds and methyl tert-butyl ether by the Dover National Test Site analytical laboratory. Volatile organic compounds were above the method reporting limits in 59 of the 115 ground-water samples. The concentrations ranged from below detection limits to maximum values of 12.4 micrograms per liter of cis-1,2-dichloroethene, 1.14 micrograms per liter of trichloroethene, 2.65 micrograms per liter of tetrachloroethene, 1,070 micrograms per liter of methyl tert-butyl ether, 4.36 micrograms per liter of benzene, and 1.8 micrograms per liter of toluene. Vinyl chloride, ethylbenzene, p,m-xylene, and o-xylene were not detected in any of the samples collected during this investigation. Methyl tert-butyl ether was detected in 47 of the 115 ground-water samples. The highest methyl tert-butyl ether concentrations were found in the surficial aquifer from -4.6 to 6.4 feet mean sea level, however, methyl tert-butyl ether was detected as deep as -9.5 feet mean sea level. Increased methane concentrations and decreased dissolved oxygen concentrations were found in samples that contained methyl tert-butyl ether.

  6. Pushpoint sampling for defining spatial and temporal variations in contaminant concentrations in sediment pore water near the ground-water / surface-water interface

    USGS Publications Warehouse

    Zimmerman, Marc J.; Massey, Andrew J.; Campo, Kimberly W.

    2005-01-01

    During four periods from April 2002 to June 2003, pore-water samples were taken from river sediment within a gaining reach (Mill Pond) of the Sudbury River in Ashland, Massachusetts, with a temporary pushpoint sampler to determine whether this device is an effective tool for measuring small-scale spatial variations in concentrations of volatile organic compounds and selected field parameters (specific conductance and dissolved oxygen concentration). The pore waters sampled were within a subsurface plume of volatile organic compounds extending from the nearby Nyanza Chemical Waste Dump Superfund site to the river. Samples were collected from depths of 10, 30, and 60 centimeters below the sediment surface along two 10-meter-long, parallel transects extending into the river. Twenty-five volatile organic compounds were detected at concentrations ranging from less than 1 microgram per liter to hundreds of micrograms per liter (for example, 1,2-dichlorobenzene, 490 micrograms per liter; cis-1,2-dichloroethene, 290 micrograms per liter). The most frequently detected compounds were either chlorobenzenes or chlorinated ethenes. Many of the compounds were detected only infrequently. Quality-control sampling indicated a low incidence of trace concentrations of contaminants. Additional samples collected with passive-water-diffusion-bag samplers yielded results comparable to those collected with the pushpoint sampler and to samples collected in previous studies at the site. The results demonstrate that the pushpoint sampler can yield distinct samples from sites in close proximity; in this case, sampling sites were 1 meter apart horizontally and 20 or 30 centimeters apart vertically. Moreover, the pushpoint sampler was able to draw pore water when inserted to depths as shallow as 10 centimeters below the sediment surface without entraining surface water. The simplicity of collecting numerous samples in a short time period (routinely, 20 to 30 per day) validates the use of a pushpoint sampler as a highly effective tool for mapping the extent of contaminated subsurface plumes, determining their constituents and loadings, and performing technical studies that may be relevant to bioremediation and other activities.

  7. Typhoid outbreak investigation in Dzivaresekwa, suburb of Harare City, Zimbabwe, 2011.

    PubMed

    Muti, Monica; Gombe, Notion; Tshimanga, Mufuta; Takundwa, Lucia; Bangure, Donewell; Mungofa, Stanley; Chonzi, Prosper

    2014-01-01

    Typhoid fever is a systemic infection caused by a Gram negative bacterium, Salmonella typhi. Harare City reported 1078 cases of suspected typhoid fever cases from October 2011 to January 2012. We initiated an investigation to identify possible source of transmission so as to institute control measures. An unmatched 1:1 case-control study was conducted. A questionnaire was administered to study participants to identify risk factors for contracting typhoid. A case was a resident of Dzivaresekwa who presented with signs and symptoms of typhoid between October and December 2011. Water samples were collected for microbiological analysis. 115 cases and 115 controls were enrolled. Drinking water from a well (OR=6.2 95% CI (2.01-18.7)), attending a gathering (OR=11.3 95% CI (4.3-29.95)), boiling drinking water (OR=0.21 95% CI (0.06-0.76)) and burst sewer pipe at home (OR=1.19 95% CI (0.67-2.14)) were factors associated with contracting typhoid. Independent risk factors for contracting typhoid were drinking water from a well (AOR=5.8; 95% CI (1.90-17.78)), and burst sewer pipe at home (AOR=1.20; 95% CI (1.10-2.19)). Faecal coli forms and E. coli were isolated from 8/8 well water samples. Stool, urine and blood specimens were cultured and serotyped for Salmonella typhi and 24 cases were confirmed positive. Shigella, Giardia and E coli were also isolated. Ciprofloxacin, X-pen and Rocephin were used for case management. No complications were reported. Contaminated water from unprotected water sources was the probable source of the outbreak. Harare City Engineer must invest in repairing water and sewage reticulation systems in the city.

  8. Geochemistry of metal-rich brines from central Mississippi Salt Dome basin, U.S.A.

    USGS Publications Warehouse

    Kharaka, Y.K.; Maest, A.S.; Carothers, W.W.; Law, L.M.; Lamothe, P.J.; Fries, T.L.

    1987-01-01

    Oil-field brines are the most favored ore-forming solutions for the sediment-hosted Mississippi Valley-type ore deposits. Detailed inorganic and organic chemical and isotope analyses of water and gas samples from six oil fields in central Mississippi, one of the very few areas with high metal brines, were conducted to study the inorganic and organic complexes responsible for the high concentrations of these metals. The samples were obtained from production zones consisting of sandstone and limestone that range in depth from 1900 to 4000 m (70-120??C) and in age from Late Cretaceous to Late Jurassic. Results show that the waters are dominantly bittern brines related to the Louann Salt. The brines have extremely high salinities that range from 160,000 to 320,000 mg/l total dissolved solids and are NaCaCl-type waters with very high concentrations of Ca (up to 48,000 mg/l) and other alkaline-earth metals, but with low concentrations of aliphatic acid anions. The concentrations of metals in many water samples are very high, reaching values of 70 mg/l for Pb, 245 mg/l for Zn, 465 mg/l for Fe and 210 mg/l for Mn. The samples with high metal contents have extremely low concentrations (<0.02 mg/l) of H2S. Samples obtained from the Smackover Formation (limestone) have low metal contents that are more typical of oil-field waters, but have very high concentrations (up to 85 mg/l) of H2S. Computations with the geochemical code SOLMINEQ.87 give the following results: (1) both Pb and Zn are present predominantly as aqueous chloride complexes (mainly as PbCl42- and ZnCl42-, respectively); (2) the concentrations of metals complexed with short-chained aliphatic acid anions and reduced S species are minor; (3) organic acid anions are important in controlling the concentrations of metals because they affect the pH and buffer capacity of the waters at subsurface conditions; and (4) galena and sphalerite solubilities control the concentrations of Pb and Zn in these waters. ?? 1988.

  9. Dynamical behaviors of structural, constrained and free water in calcium- and magnesium-silicate-hydrate gels

    DOE PAGES

    Le, Peisi; Fratini, Emiliano; Ito, Kanae; ...

    2016-01-28

    We present the hypothesis that the mechanical properties of cement pastes depend strongly on their porosities. In a saturated paste, the porosity links to the free water volume after hydration. Structural water, constrained water, and free water have different dynamical behavior. Hence, it should be possible to extract information on pore system by exploiting the water dynamics. With our experiments we investigated the slow dynamics of hydration water confined in calcium- and magnesium-silicate-hydrate (C-S-H and M-S-H) gels using high-resolution quasi-elastic neutron scattering (QENS) technique. C-S-H and M-S-H are the chemical binders present in calcium rich and magnesium rich cements. Wemore » measured three M-S-H samples: pure M-S-H, M-S-H with aluminum-silicate nanotubes (ASN), and M-S-H with carboxyl group functionalized ASN (ASN-COOH). A C-S-H sample with the same water content (i.e. 0.3) is also studied for comparison. We found that structural water in the gels contributes to the elastic component of the QENS spectrum, while constrained water and free water contribute the quasi-elastic component. The quantitative analysis suggests that the three components vary for different samples and indicate the variance in the system porosity, which controls the mechanical properties of cement pastes.« less

  10. Dynamical behaviors of structural, constrained and free water in calcium- and magnesium-silicate-hydrate gels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le, Peisi; Fratini, Emiliano; Ito, Kanae

    We present the hypothesis that the mechanical properties of cement pastes depend strongly on their porosities. In a saturated paste, the porosity links to the free water volume after hydration. Structural water, constrained water, and free water have different dynamical behavior. Hence, it should be possible to extract information on pore system by exploiting the water dynamics. With our experiments we investigated the slow dynamics of hydration water confined in calcium- and magnesium-silicate-hydrate (C-S-H and M-S-H) gels using high-resolution quasi-elastic neutron scattering (QENS) technique. C-S-H and M-S-H are the chemical binders present in calcium rich and magnesium rich cements. Wemore » measured three M-S-H samples: pure M-S-H, M-S-H with aluminum-silicate nanotubes (ASN), and M-S-H with carboxyl group functionalized ASN (ASN-COOH). A C-S-H sample with the same water content (i.e. 0.3) is also studied for comparison. We found that structural water in the gels contributes to the elastic component of the QENS spectrum, while constrained water and free water contribute the quasi-elastic component. The quantitative analysis suggests that the three components vary for different samples and indicate the variance in the system porosity, which controls the mechanical properties of cement pastes.« less

  11. 46 CFR 160.062-4 - Inspections and tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...

  12. 46 CFR 160.062-4 - Inspections and tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...

  13. 46 CFR 160.062-4 - Inspections and tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...

  14. 46 CFR 160.062-4 - Inspections and tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... required under § 160.062-3(b) while the device is submerged in water or in a water-filled pressure testing... manual control as a result of the low temperature exposure. (iii) Corrosion resisting test. After the completion of its temperature test, a hydraulic release sample shall be exposed to a 20 percent salt spray...

  15. ENVIRONMENTAL ASSESSMENT OF A FIRETUBE BOILER FIRING COAL/OIL/WATER MIXTURES. VOLUME 1. TECHNICAL RESULTS

    EPA Science Inventory

    This volume describes emission results from sampling of flue gas from a firetube boiler burning a coal/oil/water (COW) mixture and COW with soda ash added (COW+SA) to control SO2 emissions. Measurements included: continuous monitoring of flue gas emissions; source assessment samp...

  16. A large multi-pathogen gastroenteritis outbreak caused by drinking contaminated water from antique neighbourhood fountains, Erzurum city, Turkey, December 2012.

    PubMed

    Sezen, F; Aval, E; Ağkurt, T; Yilmaz, Ş; Temel, F; Güleşen, R; Korukluoğlu, G; Sucakli, M B; Torunoğlu, M A; Zhu, B-P

    2015-03-01

    We investigated a gastroenteritis outbreak in Erzurum city, Turkey in December 2012 to identify its cause and mode of transmission. We defined a probable case as onset of diarrhoea (⩾3 episodes/day) or vomiting, plus fever or nausea or abdominal pain during 19-27 December, 2012 in an Erzurum city resident. In a case-control study we compared exposures of 95 randomly selected probable cases and 95 neighbourhood-matched controls. We conducted bacterial culture and real-time multiplex PCR for identification of pathogens. During the week before illness onset, 72% of cases and 15% of controls only drank water from antique neighbourhood fountains; conversely, 16% of cases and 65% of controls only drank bottled or tap water (adjusted odds ratio 20, 95% confidence interval 4·6-84, after controlling for age and sex using conditional logistic regression). Of eight stool specimens collected, two were positive for Shigella sonnei, one for astrovirus, one for astrovirus and norovirus, and one for astrovirus and rotavirus. Water samples from the fountains had elevated total coliform (38-300/100 ml) and Escherichia coli (22-198/100 ml) counts. In conclusion, drinking contaminated fountain water caused this multi-pathogen outbreak. Residents should stop drinking water from these fountains, and clean water from the water treatment plant should be connected to the fountains.

  17. Hydrogeochemical processes controlling changes in fluoride ion concentration within alluvial and hard rock aquifers in a part of a semi-arid region of Northern India

    NASA Astrophysics Data System (ADS)

    Singh, Priyadarshini; Ashthana, Harshita; Rena, Vikas; Kumar, Pardeep; Mukherjee, Saumitra

    2017-04-01

    Geochemical signatures from alluvial and hard rock aquifers in a part of Northern India elucidate the chemical processes controlling fluctuations in fluoride ion concentration linked to changes in major ion groundwater chemistry. Majority of samples from the hard rock and the alluvial aquifers for pre-monsoon show both carbonate and silicate weathering, ion exchange, evaporation and rock water interaction as the processes controlling major ion chemistry whereas for post monsoon samples, contribution of silicate weathering and ion exchange process were observed. Evaporative processes causing the increase in Na+ ion concentration in premonsoon enhance the reverse ion exchange processes causing increase in Ca2+ ions which impedes fluorite mineral dissolution in the premonsoon groundwater samples within the study area. Alternately, it is observed that the removal of Ca2+ ion from solution plays a key role in increase in fluorite mineral dissolution despite its saturation in groundwater in the postmonsoon samples. Also, ion exchange process on clay surfaces is more pronounced in the postmonsoon samples leading to the uptake of Ca2+ ion upon release of Na+ and K+ ion in solution. Ca2+ ion concentration is inversely correlated with F- ion concentration in both the aquifers in the postmonsoon season validating the role of calcite precipitation as a major reason for the fluoride ion increase. Moreover, increase in silicate weathering in the postmonsoon samples leads to increase in clay particles acting as suitable sites for ion exchange enhancing Ca2+ removal from groundwater. Cationic dominance of Na+ ion in the post monsoon samples also validates the occurrence of this process. Collectively, these processes set the ideal conditions for increase in the fluoride ion concentration particularly in the alluvium aquifer waters in the postmonsoon season Keywords: geochemistry, ion-exchange, rock-water interaction, mineral dissolution, weathering.

  18. Cadmium distribution in forest ecosystems irrigated with treated municipal waste water and sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sidle, R.C.; Sopper, W.E.

    1976-01-01

    Treated municipal waste water was irrigated in an abandoned old field area from 1964 to 1974 and in a mixed hardwood area (old gamelands) from 1964 to 1974. Total applications of Cd in the old field and old gamelands areas were 0.47 and 0.61 kg/ha, respectively. White spruce (Picea glauca Moench Voss.) and wild strawberry (Fragaria virginiana Duchesne) foilage sampled from the old field showed no increase in Cd concentrations due to effluent irrigation, while goldenrod (Solidago sp. Ait.) had lower Cd levels in the treated area than in the unirrigated control area. Foilage sampled from red maple (Acer rubrummore » L.), white oak (Quercus alba L.), and wild sarsaparilla (Aralia nudicaulis L.), in the old gamelands, showed no increase in Cd as a result of waste water irrigation. Soil Cd levels were not significantly affected by waste water irrigation in either area, except for the increase in soil Cd in the 0 to 5 cm depth of the old gamelands. The Cd/Zn ratios of the vegetation foilage were not significantly different between the treated and control areas.« less

  19. Significance of bacteria associated with invertebrates in drinking water distribution networks.

    PubMed

    Wolmarans, E; du Preez, H H; de Wet, C M E; Venter, S N

    2005-01-01

    The implication of invertebrates found in drinking water distribution networks to public health is of concern to water utilities. Previous studies have shown that the bacteria associated with the invertebrates could be potentially pathogenic to humans. This study investigated the level and identity of bacteria commonly associated with invertebrates collected from the drinking water treatment systems as well as from the main pipelines leaving the treatment works. On all sampling occasions bacteria were isolated from the invertebrate samples collected. The highest bacterial counts were observed for the samples taken before filtration as was expected. There were, however, indications that optimal removal of invertebrates from water did not always occur. During the investigation, 116 colonies were sampled for further identification. The isolates represent several bacterial genera and species that are pathogenic or opportunistic pathogens of humans. Diarrhoea, meningitis, septicaemia and skin infections are among the diseases associated with these organisms. The estimated number of bacteria that could be associated with a single invertebrate (as based on average invertebrate numbers) could range from 10 to 4000 bacteria per organism. It can, therefore, be concluded that bacteria associated with invertebrates might under the worst case scenario pose a potential health risk to water users. In the light of the above findings it is clear that invertebrates in drinking water should be controlled at levels as low as technically and economically feasible.

  20. Metagenomic Characterization of Antibiotic Resistance Genes in Full-Scale Reclaimed Water Distribution Systems and Corresponding Potable Systems.

    PubMed

    Garner, Emily; Chen, Chaoqi; Xia, Kang; Bowers, Jolene; Engelthaler, David M; McLain, Jean; Edwards, Marc A; Pruden, Amy

    2018-06-05

    Water reclamation provides a valuable resource for meeting nonpotable water demands. However, little is known about the potential for wastewater reuse to disseminate antibiotic resistance genes (ARGs). Here, samples were collected seasonally in 2014-2015 from four U.S. utilities' reclaimed and potable water distribution systems before treatment, after treatment, and at five points of use (POU). Shotgun metagenomic sequencing was used to profile the resistome (i.e., full contingent of ARGs) of a subset ( n = 38) of samples. Four ARGs ( qnrA, bla TEM , vanA, sul1) were quantified by quantitative polymerase chain reaction. Bacterial community composition (via 16S rRNA gene amplicon sequencing), horizontal gene transfer (via quantification of intI1 integrase and plasmid genes), and selection pressure (via detection of metals and antibiotics) were investigated as potential factors governing the presence of ARGs. Certain ARGs were elevated in all ( sul1; p ≤ 0.0011) or some ( bla TEM , qnrA; p ≤ 0.0145) reclaimed POU samples compared to corresponding potable samples. Bacterial community composition was weakly correlated with ARGs (Adonis, R 2 = 0.1424-0.1734) and associations were noted between 193 ARGs and plasmid-associated genes. This study establishes that reclaimed water could convey greater abundances of certain ARGs than potable waters and provides observations regarding factors that likely control ARG occurrence in reclaimed water systems.

Top