WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dadkhah, H; Wu, X; Kim, Y
Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls asmore » well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable timeframe.« less
Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich
2016-07-01
A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... on the remote afterloader unit, on the control console, and in the facility; (3) Viewing and intercom... monitors used to indicate room exposures; (6) Source positioning (accuracy); and (7) Radiation monitors...
10 CFR 35.643 - Periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Periodic spot-checks for remote afterloader units. 35.643... spot-checks for remote afterloader units. (a) A licensee authorized to use a remote afterloader unit for medical use shall perform spot-checks of each remote afterloader facility and on each unit— (1...
Altered LV inotropic reserve and mechanoenergetics early in the development of heart failure.
Prabhu, S D; Freeman, G L
2000-03-01
To test the hypothesis that alterations in left ventricular (LV) mechanoenergetics and the LV inotropic response to afterload manifest early in the evolution of heart failure, we examined six anesthetized dogs instrumented with LV micromanometers, piezoelectric crystals, and coronary sinus catheters before and after 24 h of rapid ventricular pacing (RVP). After autonomic blockade, the end-systolic pressure-volume relation (ESPVR), myocardial O(2) consumption (MVO(2)), and LV pressure-volume area (PVA) were defined at several different afterloads produced by graded infusions of phenylephrine. Short-term RVP resulted in reduced preload with proportionate reductions in stroke work and the maximum first derivative of LV pressure but with no significant reduction in baseline LV contractile state. In response to increased afterload, the baseline ESPVR shifted to the left with maintained end-systolic elastance (E(es)). In contrast, after short-term RVP, in response to comparable increases in afterload, the ESPVR displayed reduced E(es) (P < 0.05) and significantly less leftward shift compared with control (P < 0.05). Compared with the control MVO(2)-PVA relation, short-term RVP significantly increased the MVO(2) intercept (P < 0.05) with no change in slope. These results indicate that short-term RVP produces attenuation of afterload-induced enhancement of LV performance and increases energy consumption for nonmechanical processes with maintenance of contractile efficiency, suggesting that early in the development of tachycardia heart failure, there is blunting of length-dependent activation and increased O(2) requirements for excitation-contraction coupling, basal metabolism, or both. Rather than being adaptive mechanisms, these abnormalities may be primary defects involved in the progression of the heart failure phenotype.
10 CFR 35.2647 - Records of additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... remote afterloader units. 35.2647 Section 35.2647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2647 Records of additional technical requirements for mobile remote afterloader units. (a) A licensee shall retain a record of each check for mobile remote afterloader units...
10 CFR 35.2647 - Records of additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... remote afterloader units. 35.2647 Section 35.2647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2647 Records of additional technical requirements for mobile remote afterloader units. (a) A licensee shall retain a record of each check for mobile remote afterloader units...
10 CFR 35.2647 - Records of additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... remote afterloader units. 35.2647 Section 35.2647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2647 Records of additional technical requirements for mobile remote afterloader units. (a) A licensee shall retain a record of each check for mobile remote afterloader units...
10 CFR 35.2647 - Records of additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... remote afterloader units. 35.2647 Section 35.2647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2647 Records of additional technical requirements for mobile remote afterloader units. (a) A licensee shall retain a record of each check for mobile remote afterloader units...
10 CFR 35.2647 - Records of additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... remote afterloader units. 35.2647 Section 35.2647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2647 Records of additional technical requirements for mobile remote afterloader units. (a) A licensee shall retain a record of each check for mobile remote afterloader units...
10 CFR 35.2643 - Records of periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Records of periodic spot-checks for remote afterloader... Records § 35.2643 Records of periodic spot-checks for remote afterloader units. (a) A licensee shall retain a record of each spot-check for remote afterloader units required by § 35.643 for 3 years. (b) The...
10 CFR 35.2643 - Records of periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Records of periodic spot-checks for remote afterloader... Records § 35.2643 Records of periodic spot-checks for remote afterloader units. (a) A licensee shall retain a record of each spot-check for remote afterloader units required by § 35.643 for 3 years. (b) The...
10 CFR 35.2643 - Records of periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Records of periodic spot-checks for remote afterloader... Records § 35.2643 Records of periodic spot-checks for remote afterloader units. (a) A licensee shall retain a record of each spot-check for remote afterloader units required by § 35.643 for 3 years. (b) The...
10 CFR 35.2643 - Records of periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Records of periodic spot-checks for remote afterloader... Records § 35.2643 Records of periodic spot-checks for remote afterloader units. (a) A licensee shall retain a record of each spot-check for remote afterloader units required by § 35.643 for 3 years. (b) The...
10 CFR 35.2643 - Records of periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Records of periodic spot-checks for remote afterloader... Records § 35.2643 Records of periodic spot-checks for remote afterloader units. (a) A licensee shall retain a record of each spot-check for remote afterloader units required by § 35.643 for 3 years. (b) The...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glasgow, G.P.; Corrigan, K.W.
We have renovated, and used for four years, a small 3.4 m x 4.3 m conventional patient second floor hospital room to accommodate a low dose rate remote afterloading unit containing 13 GBq (0.35 Ci) of {sup 137}Cs. Supplemental room shielding consists of a power assisted door (536 kg, 1.7 cm thickness of lead), 1.3 cm lead wall shielding at selected wall locations and on a projector shield beneath the bed, and 0.6 cm of lead over the floor above. Radiation control features consisted of a room interior radiation detector independent of the remote afterloading unit, a redundant patient/nurse communicationmore » system, a remote control system, a door interlock system to insert and retract the radioactive pellets, and a visible and audible status indictator system located at a nearby nurses` work station. Renovation costs (in 1990 dollars) were $383 per square foot; total project costs were $187,000. Nursing personnel radiation exposure was reduced from about 6 {mu}Sv (mg Ra eq){sup -1} (0.6 mrem (mg Ra eq){sup -1}) to about 0.7 {mu}Sv (mg Ra eq){sup -1} (0.07 mrem (mg Ra eq){sup -1}), almost a tenfold reduction. 6 refs., 2 figs., 1 tab.« less
10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Additional technical requirements for mobile remote afterloader units. 35.647 Section 35.647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery...
10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Additional technical requirements for mobile remote afterloader units. 35.647 Section 35.647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery...
10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Additional technical requirements for mobile remote afterloader units. 35.647 Section 35.647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery...
10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Additional technical requirements for mobile remote afterloader units. 35.647 Section 35.647 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery...
10 CFR 35.633 - Full calibration measurements on remote afterloader units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Full calibration measurements on remote afterloader units. 35.633 Section 35.633 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.633...
10 CFR 35.643 - Periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Periodic spot-checks for remote afterloader units. 35.643 Section 35.643 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.643 Periodic...
10 CFR 35.633 - Full calibration measurements on remote afterloader units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Full calibration measurements on remote afterloader units. 35.633 Section 35.633 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.633...
10 CFR 35.643 - Periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Periodic spot-checks for remote afterloader units. 35.643 Section 35.643 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.643 Periodic...
10 CFR 35.643 - Periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Periodic spot-checks for remote afterloader units. 35.643 Section 35.643 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.643 Periodic...
10 CFR 35.633 - Full calibration measurements on remote afterloader units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Full calibration measurements on remote afterloader units. 35.633 Section 35.633 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.633...
10 CFR 35.643 - Periodic spot-checks for remote afterloader units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Periodic spot-checks for remote afterloader units. 35.643 Section 35.643 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.643 Periodic...
10 CFR 35.633 - Full calibration measurements on remote afterloader units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Full calibration measurements on remote afterloader units. 35.633 Section 35.633 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.633...
10 CFR 35.633 - Full calibration measurements on remote afterloader units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Full calibration measurements on remote afterloader units. 35.633 Section 35.633 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.633...
Intrinsic increase in lymphangion muscle contractility in response to elevated afterload
Scallan, Joshua P.; Wolpers, John H.; Muthuchamy, Mariappan; Gashev, Anatoliy A.; Zawieja, David C.
2012-01-01
Collecting lymphatic vessels share functional and biochemical characteristics with cardiac muscle; thus, we hypothesized that the lymphatic vessel pump would exhibit behavior analogous to homeometric regulation of the cardiac pump in its adaptation to elevated afterload, i.e., an increase in contractility. Single lymphangions containing two valves were isolated from the rat mesenteric microcirculation, cannulated, and pressurized for in vitro study. Pressures at either end of the lymphangion [input pressure (Pin), preload; output pressure (Pout), afterload] were set by a servo controller. Intralymphangion pressure (PL) was measured using a servo-null micropipette while internal diameter and valve positions were monitored using video methods. The responses to step- and ramp-wise increases in Pout (at low, constant Pin) were determined. PL and diameter data recorded during single contraction cycles were used to generate pressure-volume (P-V) relationships for the subsequent analysis of lymphangion pump behavior. Ramp-wise Pout elevation led to progressive vessel constriction, a rise in end-systolic diameter, and an increase in contraction frequency. Step-wise Pout elevation produced initial vessel distention followed by time-dependent declines in end-systolic and end-diastolic diameters. Significantly, a 30% leftward shift in the end-systolic P-V relationship accompanied an 84% increase in dP/dt after a step increase in Pout, consistent with an increase in contractility. Calculations of stroke work from the P-V loop area revealed that robust pumps produced net positive work to expel fluid throughout the entire afterload range, whereas weaker pumps exhibited progressively more negative work as gradual afterload elevation led to pump failure. We conclude that lymphatic muscle adapts to output pressure elevation with an intrinsic increase in contractility and that this compensatory mechanism facilitates the maintenance of lymph pump output in the face of edemagenic and/or gravitational loads. PMID:22886407
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullins, JP; Deufel, CL
Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives thatmore » it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we have the ability to quantitatively evaluate and track our afterloader performance for a technically challenging ERCP brachytherapy procedure.« less
Gregory, Shaun D; Schummy, Emma; Pearcy, Mark; Pauls, Jo P; Tansley, Geoff; Fraser, John F; Timms, Daniel
2015-02-01
Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.
Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung
2009-08-01
The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callan, J.R.; Kelly, R.T.; Quinn, M.L.
1995-05-01
Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices usedmore » in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error.« less
Unique strain history during ejection in canine left ventricle.
Douglas, A S; Rodriguez, E K; O'Dell, W; Hunter, W C
1991-05-01
Understanding the relationship between structure and function in the heart requires a knowledge of the connection between the local behavior of the myocardium (e.g., shortening) and the pumping action of the left ventricle. We asked the question, how do changes in preload and afterload affect the relationship between local myocardial deformation and ventricular volume? To study this, a set of small radiopaque beads was implanted in approximately 1 cm3 of the isolated canine heart left ventricular free wall. Using biplane cineradiography, we tracked the motion of these markers through various cardiac cycles (controlling pre- and afterload) using the relative motion of six markers to quantify the local three dimensional Lagrangian strain. Two different reference states (used to define the strains) were considered. First, we used the configuration of the heart at end diastole for that particular cardiac cycle to define the individual strains (which gave the local "shortening fraction") and the ejection fraction. Second, we used a single reference state for all cardiac cycles i.e., the end-diastolic state at maximum volume, to define absolute strains (which gave local fractional length) and the volume fraction. The individual strain versus ejection fraction trajectories were dependent on preload and afterload. For any one heart, however, each component of absolute strain was more tightly correlated to volume fraction. Around each linear regression, the individual measurements of absolute strain scattered with standard errors that averaged less than 7% of their range. Thus the canine hearts examined had a preferred kinematic (shape) history during ejection, different from the kinematics of filling and independent or pre-or afterload and of stroke volume.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grigsby, P.W.; Perez, C.A.; Eichling, J.
The radiation exposure to nursing personnel from patients with brachytherapy implants on a large brachytherapy service were reviewed. Exposure to nurses, as determined by TLD monitors, indicates a 7-fold reduction in exposure after the implementation of the use of remote afterloading devices. Quarterly TLD monitor data for six quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the nurses of 152 and 154 mrem (1.5 mSv). After the implementation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per nurse of 23 and 19 mrem (0.2more » mSv). This is an 87% reduction in exposure to nurses with the use of these devices (p less than 0.01).« less
Impact of afterload on the assessment of severity of aortic stenosis.
Chang, Sung-A; Kim, Hyung-Kwan; Sohn, Dae-Won
2012-06-01
Aortic stenosis (AS) is increasingly diagnosed in current aging society. Echocardiography is the most important tool in the assessment of AS and its severity. However, load-dependency of Doppler measurement could affect the accuracy of AS severity assessment. We tried to evaluate the impact of afterload on the assessment of AS severity by modification of afterload using pneumatic compression (Pcom). Forty patients diagnosed as moderate or severe AS [effective orifice area of aortic valve (EOA(AV)) by continuity equation of < 1.5 cm(2)] were consecutively enrolled. Patients with severely uncontrolled hypertension, severe left ventricular (LV) dysfunction, and other significant valve disease were excluded. Comprehensive echocardiography was performed at baseline to assess AS severity. Then, pneumatic compression of the lower extremities by 100 mmHg was applied to increase LV afterload. After 3 minutes, echocardiography was repeated to assess AS severity. Mean blood pressure was significantly increased under Pcom (p < 0.001), while heart rate remained unchanged. Peak aortic valve velocity (V(max)) was slightly, but significantly decreased under Pcom (p = 0.03). However, Doppler velocity index and EOA(AV) by continuity equation were not affected by Pcom. AS severity assessment by echocardiography was not dependent on the change of LV afterload imposed by Pcom. AV V(max) was slightly decreased with LV afterload increment, but these changes were too small to alter treatment plan of AS patients. EOA(AV) and Doppler velocity index are more stable parameters for AS severity assessment.
Mellors, L J; Gibbs, C L; Barclay, C J
2001-05-01
The results of previous studies suggest that the maximum mechanical efficiency of rat papillary muscles is lower during a contraction protocol involving sinusoidal length changes than during one involving afterloaded isotonic contractions. The aim of this study was to compare directly the efficiency of isolated rat papillary muscle preparations in isotonic and sinusoidal contraction protocols. Experiments were performed in vitro (27 degrees C) using left ventricular papillary muscles from adult rats. Each preparation performed three contraction protocols: (i) low-frequency afterloaded isotonic contractions (10 twitches at 0.2 Hz), (ii) sinusoidal length change contractions with phasic stimulation (40 twitches at 2 Hz) and (iii) high-frequency afterloaded isotonic contractions (40 twitches at 2 Hz). The first two protocols resembled those used in previous studies and the third combined the characteristics of the first two. The parameters for each protocol were adjusted to those that gave maximum efficiency. For the afterloaded isotonic protocols, the afterload was set to 0.3 of the maximum developed force. The sinusoidal length change protocol incorporated a cycle amplitude of +/-5% resting length and a stimulus phase of -10 degrees. Measurements of force output, muscle length change and muscle temperature change were used to calculate the work and heat produced during and after each protocol. Net mechanical efficiency was defined as the proportion of the energy (enthalpy) liberated by the muscle that appeared as work. The efficiency in the low-frequency, isotonic contraction protocol was 21.1+/-1.4% (mean +/- s.e.m., N=6) and that in the sinusoidal protocol was 13.2+/-0.7%, consistent with previous results. This difference was not due to the higher frequency or greater number of twitches because efficiency in the high-frequency, isotonic protocol was 21.5+/-1.0%. Although these results apparently confirm that efficiency is protocol-dependent, additional experiments designed to measure work output unambiguously indicated that the method used to calculate work output in isotonic contractions overestimated actual work output. When net work output, which excludes work done by parallel elastic elements, rather than total work output was used to determine efficiency in afterloaded isotonic contractions, efficiency was similar to that for sinusoidal contractions. The maximum net mechanical efficiency of rat papillary muscles performing afterloaded isotonic or sinusoidal length change contractions was between 10 and 15%.
Code of Federal Regulations, 2010 CFR
2010-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2011 CFR
2011-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2014 CFR
2014-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2013 CFR
2013-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2012 CFR
2012-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ledee, Dolena; Portman, Michael A.; Kajimoto, Masaki
Background: Subclinical hypothyroidism occurs during aging in humans and mice and may contribute to development of heart failure. Aging also impairs myocardial fatty acid oxidation, causing increased reliance on flux through pyruvate dehydrogenase (PDH) to maintain function. We hypothesize that the metabolic changes in aged hearts make them less tolerant to acutely increased work and that thyroid hormone reverses these defects. Methods: Studies were performed on young (Young, 4-6 months) and aged (Old, 22-24 months) C57/BL6 mice at standard (50 mmHg) and high afterload (80 mmHg). Another aged group received thyroid hormone for 3 weeks (Old-TH, high afterload only). Functionmore » was measured in isolated working hearts along with substrate fractional contributions (Fc) to the citric acid cycle (CAC) using perfusate with 13C labeled lactate, pyruvate, glucose and unlabeled palmitate and insulin. Results: Cardiac function was similar between Young and Old mice at standard afterload. Palmitate Fc was reduced but no individual carbohydrate contributions differed. CAC and individual substrate fluxes decreased in aged. At high afterload, -dP/dT was decreased in Old versus Young. Similar to low afterload, palmitate Fc was decreased in Old. Thyroid hormone reversed aging-induced changes in palmitate Fc and flux while significantly improving cardiac function. Conclusion: The aged heart shows diminished ability to increase cardiac work due to substrate limitations, primarily impaired fatty acid oxidation. The heart accommodates slightly by increasing efficiency through oxidation of carbohydrate substrates. Thyroid hormone supplementation in aged mice significantly improves cardiac function potentially through restoration of fatty acid oxidation.« less
A new after-loading intrauterine packing device: ten years experience.
Sklaroff, D M; Baker, A S; Tasbas, M
1985-12-01
A new variation of the uterine packing device for the treatment of endometrial carcinoma is described. It combines the advantages of the Holter technique with the after-loading method described by Simon. This device has been in use for more than 10 years and has been found most satisfactory.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.690 Section 35.690 Energy NUCLEAR REGULATORY...) Radiation physics and instrumentation; (B) Radiation protection; (C) Mathematics pertaining to the use and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.690 Section 35.690 Energy NUCLEAR REGULATORY...) Radiation physics and instrumentation; (B) Radiation protection; (C) Mathematics pertaining to the use and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.690 Section 35.690 Energy NUCLEAR REGULATORY...) Radiation physics and instrumentation; (B) Radiation protection; (C) Mathematics pertaining to the use and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.690 Section 35.690 Energy NUCLEAR REGULATORY...) Radiation physics and instrumentation; (B) Radiation protection; (C) Mathematics pertaining to the use and...
TU-C-201-02: Clinical Implementation of HDR: Afterloader and Applicator Selection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esthappan, J.
2015-06-15
Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for eachmore » institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.« less
Wink, Jeroen; de Wilde, Rob B P; Wouters, Patrick F; van Dorp, Eveline L A; Veering, Bernadette Th; Versteegh, Michel I M; Aarts, Leon P H J; Steendijk, Paul
2016-10-18
Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia may affect right ventricular function and interfere with the coupling between right ventricular function and right ventricular afterload. Our main objectives were to study the effects of thoracic epidural anesthesia on right ventricular function and ventricular-pulmonary coupling. In 10 patients scheduled for lung resection, right ventricular function and its response to increased afterload, induced by temporary, unilateral clamping of the pulmonary artery, was tested before and after induction of thoracic epidural anesthesia using combined pressure-conductance catheters. Thoracic epidural anesthesia resulted in a significant decrease in right ventricular contractility (ΔESV 25 : +25.5 mL, P=0.0003; ΔEes: -0.025 mm Hg/mL, P=0.04). Stroke work, dP/dt MAX , and ejection fraction showed a similar decrease in systolic function (all P<0.05). A concomitant decrease in effective arterial elastance (ΔEa: -0.094 mm Hg/mL, P=0.004) yielded unchanged ventricular-pulmonary coupling. Cardiac output, systemic vascular resistance, and mean arterial blood pressure were unchanged. Clamping of the pulmonary artery significantly increased afterload (ΔEa: +0.226 mm Hg/mL, P<0.001). In response, right ventricular contractility increased (ΔESV 25 : -26.6 mL, P=0.0002; ΔEes: +0.034 mm Hg/mL, P=0.008), but ventricular-pulmonary coupling decreased (Δ(Ees/Ea) = -0.153, P<0.0001). None of the measured indices showed significant interactive effects, indicating that the effects of increased afterload were the same before and after thoracic epidural anesthesia. Thoracic epidural anesthesia impairs right ventricular contractility but does not inhibit the native positive inotropic response of the right ventricle to increased afterload. Right ventricular-pulmonary arterial coupling was decreased with increased afterload but not affected by the induction of thoracic epidural anesthesia. URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2844. Unique identifier: NTR2844. © 2016 American Heart Association, Inc.
Afterload-dependent flow fluctuation of centrifugal pump: should it be actively fixed?
Nishida, H; Akazawa, T; Nishinaka, T; Aomi, S; Endo, M; Koyanagi, H
1998-05-01
To evaluate the clinical meaning and effects of afterload-dependent flow fluctuation in a centrifugal pump, concomitant measurement of flow rate and mixed venous oxygen saturation (SVO2) was performed in 5 cases of open heart surgery in which the patients underwent cardiopulmonary bypass (CPB) with the Terumo Capiox centrifugal pump. Continuous measurement of SVO2 using the 3M CDI System 100 was performed with a disposable cuvette incorporated into the drainage circuit. After the target flow rate of 2.4 L/min/m2 was obtained under a nonbeating condition, the pump rotational speed was fixed. During the cooling and low temperature period, SVO2 decreased as the flow rate spontaneously decreased but still stayed around 80% even with a 15-20% decrease in blood flow rate. This indicates that a luxury perfusion condition is ensured as long as the body temperature is kept low. In contrast, during the rewarming period, SVO2 decreased to around 70-75% despite a 15-25% spontaneous increase in flow rate. Although this level of SVO2 still indicates adequate systemic perfusion, there is a possibility of regional hypoperfusion in patients with such conditions as cerebrovascular disease. In conclusion, although diligent adjustment of the physiological fluctuating flow rate in the centrifugal pump seems unnecessary during conventional open heart surgery, manual control may be necessary especially during the rewarming period, normothermic surgery, or circulatory assist for shocked patients. From this study, we also conclude that the major benefit of the afterload-independent autoflow control system of the centrifugal pump is the improvement of safety in terms of the fixed reservoir level and the handling of cardiopulmonary bypass.
Dose rate in brachytherapy using after-loading machine: pulsed or high-dose rate?
Hannoun-Lévi, J-M; Peiffert, D
2014-10-01
Since February 2014, it is no longer possible to use low-dose rate 192 iridium wires due to the end of industrial production of IRF1 and IRF2 sources. The Brachytherapy Group of the French society of radiation oncology (GC-SFRO) has recommended switching from iridium wires to after-loading machines. Two types of after-loading machines are currently available, based on the dose rate used: pulsed-dose rate or high-dose rate. In this article, we propose a comparative analysis between pulsed-dose rate and high-dose rate brachytherapy, based on biological, technological, organizational and financial considerations. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Rivard, Mark J; Evans, Dee-Ann Radford; Kay, Ian
2005-01-01
The Fully Integrated Real-time Seed Treatment (FIRST) system by Nucletron has been available in Europe since November 2001 and is being used more and more in Canada and the United States. Like the conventional transrectal ultrasound implant procedure, the FIRST system utilizes an ultrasound probe, needles, and brachytherapy seeds. However, this system is unique in that it (1) utilizes a low-dose-rate brachytherapy seed remote afterloader (the seedSelectron), (2) utilizes 3D image reconstruction acquired from electromechanically controlled, nonstepping rotation of the ultrasound probe, (3) integrates the control of a remote afterloader with electromechanical control of the ultrasound probe for integrating the clinical procedure into a single system, and (4) automates the transfer of planning information and seed delivery to improve quality assurance and radiation safety. This automated delivery system is specifically intended to address reproducibility and accuracy of seed positioning during implantation. The FIRST computer system includes two software environments: SPOT PRO and seedSelectron; both are used to facilitate treatment planning and brachytherapy seed implantation from beginning to completion of the entire procedure. In addition to these features, the system is reported to meet certain product specifications for seed delivery positioning accuracy and reproducibility, seed calibration accuracy and reliability, and brachytherapy dosimetry calculations. Consequently, a technical evaluation of the FIRST system was performed to determine adherence to manufacturer specifications and to the American Association of Physicists in Medicine (AAPM) Task Group Reports 43, 53, 56, 59, and 64 and recommendations of the American Brachytherapy Society (ABS). The United States Nuclear Regulatory Commission (NRC) has recently added Licensing Guidance for the seedSelectron system under 10 CFR 35.1000. Adherence to licensing guidance is made by referencing applicable AAPM Task Group recommendations. In general, results of this evaluation indicated that the system met its claimed specifications as well as the applicable recommendations outlined in the AAPM and ABS reports.
Johnson, Jonas; Håkansson, Felicia; Shahgaldi, Kambiz; Manouras, Aristomenis; Norman, Mikael; Sahlén, Anders
2013-04-01
Abnormal vascular-ventricular coupling has been suggested to contribute to heart failure with preserved ejection fraction in elderly females. Failure to increase stroke volume (SV) during exercise occurs in parallel with dynamic changes in arterial physiology leading to increased afterload. Such adverse vascular reactivity during stress may reflect either sympathoexcitation or be due to tachycardia. We hypothesized that afterload elevation induces SV failure by transiently attenuating left ventricular relaxation, a phenomenon described in animal research. The respective roles of tachycardia and sympathoexcitation were investigated in n = 28 elderly females (70 ± 4 yr) carrying permanent pacemakers. At rest, during atrial tachycardia pacing (ATP; 100 min(-1)) and during cold pressor test (hand immersed in ice water), we performed Doppler echocardiography (maximal untwist rate analyzed by speckle tracking imaging of rotational mechanics) and arterial tonometry (arterial stiffness estimated as augmentation index). Estimation of arterial compliance was based on an exponential relationship between arterial pressure and volume. We found that ATP produced central hypovolemia and a reduction in SV which was larger in patients with stiffer arteries (higher augmentation index). There was an associated adverse response of arterial compliance and vascular resistance during ATP and cold pressor test, causing an overall increase in afterload, but nonetheless enhanced maximal rate of untwist and no evidence of afterload-dependent failure of relaxation. In conclusion, tachycardia and cold provocation in elderly females produces greater vascular reactivity and SV failure in the presence of arterial stiffening, but SV failure does not arise secondary to afterload-dependent attenuation of relaxation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Surveys of patients and human research subjects treated... Stereotactic Radiosurgery Units § 35.604 Surveys of patients and human research subjects treated with a remote... shall survey the patient or the human research subject and the remote afterloader unit with a portable...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Surveys of patients and human research subjects treated... Stereotactic Radiosurgery Units § 35.604 Surveys of patients and human research subjects treated with a remote... shall survey the patient or the human research subject and the remote afterloader unit with a portable...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Surveys of patients and human research subjects treated... Stereotactic Radiosurgery Units § 35.604 Surveys of patients and human research subjects treated with a remote... shall survey the patient or the human research subject and the remote afterloader unit with a portable...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Surveys of patients and human research subjects treated... Stereotactic Radiosurgery Units § 35.604 Surveys of patients and human research subjects treated with a remote... shall survey the patient or the human research subject and the remote afterloader unit with a portable...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Surveys of patients and human research subjects treated... Stereotactic Radiosurgery Units § 35.604 Surveys of patients and human research subjects treated with a remote... shall survey the patient or the human research subject and the remote afterloader unit with a portable...
Selective reduction of afterload in right heart assist therapy: a mock loop study†.
Hsu, Po-Lin; Hatam, Nima; Unterkofler, Jan; Goetzenich, Andreas; McIntyre, Madeleine; Wong, Kai Chun; Egger, Christina; Schmitz-Rode, Thomas; Autschbach, Rüdiger; Steinseifer, Ulrich
2014-07-01
The treatment of right ventricular failure is closely linked to effects on pulmonary vascular resistance and thus the right ventricular (RV) afterload. Medical therapy includes afterload-decreasing drugs such as nitric oxide and prostacycline. However, current devices for mechanical unloading of the right ventricle aim at a decrease in preload increasing the pulmonary volume loading. In our concept study, we tested a minimally invasive right ventricular assist device (MIRVAD) that specifically reduces the afterload. The MIRVAD is supposed to be a foldable device for temporary transvascular placement in the pulmonary artery. We incorporated a MIRVAD prototype into a mock circulatory loop that can reproduce haemodynamic interaction between the pump and the physiological system. Pulmonary hypertension (PH), right heart failure (RHF) and MIRVAD-assisted cases were simulated. The key haemodynamic parameters for RV unloading were recorded. Mock loop simulation attested to a sufficient right ventricular unloading by serial application of a miniaturized impeller pump in the pulmonary artery. The afterload, represented by the pulmonary arterial root pressure, was recovered to the healthy range (32.62-10.93 mmHg) for the simulated PH case. In the simulated RHF case, the impaired pulmonary perfusion increased from 43.4 to 88.8% of the healthy level and the total ventricular work reduced from 0.381 to 0.197 J at a pump speed of 3500 rpm. At pump speeds higher than 3500 rpm, the pulmonary valve remains constantly open and the right ventricular configuration changes into a simple perfused hollow body. The feasibility of RV unloading by a selective decrease in RV afterload was proved in principle. By alternation of the pump speed, gradual reloading in sense of a myocardial training may be achieved. The results will be validated by future animal trials where the relationship between the level of support and pulmonary vascular pressure can be investigated in vivo. Further device design concerning foldable impeller leaflets will be carried out. At a final stage, the crimped version is supposed to reach a size below 1 cm to facilitate minimally invasive insertion. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Dunning, Jamie; Truong, Uyen; Ivy, D. Dunbar; Hunter, Kendall A.; Shandas, Robin
2015-01-01
Abstract Pulmonary arterial hypertension (PAH) is a progressive disease that puts excessive mechanical loads on the ventricle due to a gradual increase in pulmonary vascular impedance. We hypothesize that the increase in right ventricular (RV) afterload is reflected in the concentration of circulating biochemical markers of ventricular strain and stress (B-type natriuretic peptide [BNP] and N-terminal prohormone BNP [NT-proBNP]). We retrospectively analyzed right heart catheterization (RHC) and serum biochemical analysis data () for a pediatric PAH cohort with no sign of left ventricular dysfunction. Using RHC data, we computed an estimate of pulmonary vascular resistance (PVR), compliance, and ventricular-vascular coupling. We also compared how the early onset of interventricular decoupling (characterized as septal flattening) impacts serum NT-proBNP concentrations. Our data revealed correlated NT-proBNP expression with both the resistive and reactive components of RV afterload, an estimate of ventricular-vascular coupling, and a significant increase in biomarker expression in patients with a flattened interventricular septum. Furthermore, the strong correlation between PVR and NT-proBNP appears to break down under flat septum morphology. Over 80% of resistive RV afterload variance is reflected in serum NT-proBNP concentration in pediatric patients with PAH with no sign of left ventricular dysfunction. Reactive afterload appears to contribute to myocardial NT-proBNP release at advanced stages of PAH. Therefore, in mild-to-moderate PAH, resistive afterload is likely the greatest contributor to RV wall stress. These findings could also be used to estimate invasive RHC measurements from serum biochemical analysis, but more work is needed to improve correlations and overcome the issue of interventricular decoupling. PMID:26697173
A LabVIEW model incorporating an open-loop arterial impedance and a closed-loop circulatory system.
Cole, R T; Lucas, C L; Cascio, W E; Johnson, T A
2005-11-01
While numerous computer models exist for the circulatory system, many are limited in scope, contain unwanted features or incorporate complex components specific to unique experimental situations. Our purpose was to develop a basic, yet multifaceted, computer model of the left heart and systemic circulation in LabVIEW having universal appeal without sacrificing crucial physiologic features. The program we developed employs Windkessel-type impedance models in several open-loop configurations and a closed-loop model coupling a lumped impedance and ventricular pressure source. The open-loop impedance models demonstrate afterload effects on arbitrary aortic pressure/flow inputs. The closed-loop model catalogs the major circulatory waveforms with changes in afterload, preload, and left heart properties. Our model provides an avenue for expanding the use of the ventricular equations through closed-loop coupling that includes a basic coronary circuit. Tested values used for the afterload components and the effects of afterload parameter changes on various waveforms are consistent with published data. We conclude that this model offers the ability to alter several circulatory factors and digitally catalog the most salient features of the pressure/flow waveforms employing a user-friendly platform. These features make the model a useful instructional tool for students as well as a simple experimental tool for cardiovascular research.
SU-E-T-457: Design and Characterization of An Economical 192Ir Hemi-Brain Small Animal Irradiator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grams, M; Wilson, Z; Sio, T
Purpose: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. Methods: A high dose rate 192Ir brachytherapy source from a commercially available afterloader was used with a 1.3 centimeter thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit is equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film. The penumbra from the small animal irradiator was compared under similar collimating conditions to the penumbra from 6 MV photons, 6 MeV electrons, and 20 MeV electrons frommore » a linear accelerator as well as 300 kVp photons from an orthovoltage unit and Monte Carlo simulated 90 MeV protons. Results: The tungsten collimator provides a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator. Additionally, the penumbra was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. Conclusions: The small animal irradiator described here can be built for under $1,000 and used in conjunction with any commercial brachytherapy afterloader to provide a convenient and cost-effective option for small animal irradiation experiments. The unit offers high dose rate delivery and sharp penumbra, which is ideal for hemi-brain irradiation of mice. With slight modifications to the design, irradiation of sites other than the brain could be accomplished easily. Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring a sharp penumbra.« less
Fernandes-Silva, Miguel M; Shah, Amil M; Hegde, Sheila; Goncalves, Alexandra; Claggett, Brian; Cheng, Susan; Nadruz, Wilson; Kitzman, Dalane W.; Konety, Suma H.; Matsushita, Kunihiro; Mosley, Thomas; Lam, Carolyn S.P.; Borlaug, Barry A.; Solomon, Scott D
2016-01-01
Background Chronic increasing in arterial afterload may be an important trigger for left ventricular (LV) remodeling and dysfunction that lead to heart failure (HF). Racial differences in the predisposition to HF are well described, but the underlying mechanisms remain unclear. Objective We evaluated the racial differences in arterial elastance (Ea), which reflects the arterial afterload faced by the LV, and its associations with cardiac structure and function. We hypothesize that the LV in blacks displays heightened afterload sensitivity as compared to whites. Methods We studied 5727 community-based, elderly Atherosclerosis Risk in Community (ARIC) Study participants (22% black), who underwent echocardiography between 2011 and 2013. Results Blacks were younger (75 ± 5 vs 76 ± 5 years old), more frequently women (66 vs 57%), and had higher prevalence of obesity (46 vs 31%), hypertension (94 vs 80%), and diabetes mellitus (47 vs 34%) than whites. Adjusting for these baseline differences, Ea was higher among blacks (1.96 ± 0.01 vs 1.80 ± 0.01 mmHg/mL). In blacks, Ea was associated with greater LV remodeling (LV mass index, β = 3.21 ± 0.55 g/m2, p<0.001) and higher LV filling pressures (E/e′ ratio, β = 0.42 ± 0.11, p<0.001). These relationships were not observed in whites (LV mass, β = 0.16 ± 0.32 g/m2, p=0.61, p for interaction <0.001; E/e′ratio, β = −0.32 ± 0.06, p<0.001, p for interaction <0.001).. Conclusion These community-based data suggest that black Americans display heightened afterload sensitivity as a stimulus for LV structural and functional remodeling, which may contribute to their greater risk of HF, as compared to white Americans. PMID:28017356
[A novel serial port auto trigger system for MOSFET dose acquisition].
Luo, Guangwen; Qi, Zhenyu
2013-01-01
To synchronize the radiation of microSelectron-HDR (Nucletron afterloading machine) and measurement of MOSFET dose system, a trigger system based on interface circuit was designed and corresponding monitor and trigger program were developed on Qt platform. This interface and control system was tested and showed stable operate and reliable work. This adopted serial port detect technique may expand to trigger application of other medical devices.
Design of a plastic minicolpostat applicator with shields.
Weeks, K J; Montana, G S; Bentel, G C
1991-09-01
A plastic intracavitary applicator system for the treatment of cancer of the uterine cervix is described. This applicator has a minicolpostat and a mechanism for affixing the tandem to the colpostats. Traditional afterloading refers only to the radioactive source. Both the source and the ovoid shield are afterloaded together in this applicator in contrast to traditional afterloading systems which afterload the source alone. A potential advantage of our applicator system is that it allows high quality CT localization because the sources and shields can be removed and the applicator is made of plastic. The advantages and disadvantages of this variation to the Fletcher system as well as other aspects of applicator design are discussed. An experimentally verified dose calculation method for shielded sources is applied to the design problems associated with this applicator. The dose distribution calculated for a source-shield configuration of the plastic applicator is compared to that obtained with a commercial Fletcher-Suit-Delclos (FSD) applicator. Significant shielding improvements can be achieved for the smallest diameter ovoid, that is, in the minicolpostat. The plastic minicolpostat dose distributions are similar to those produced by the conventional larger diameter colpostats. In particular, the colpostat shielding for rectum and bladder, which is reduced in the metal applicator's minicolpostat configuration, is maintained for the plastic minicolpostat. Further, it is shown that, if desired, relative to the FSD minicolpostat, the mucosa dose can be reduced by a suitable change of the minicolpostat source position.
Sucharov, Carmen C.; Truong, Uyen; Dunning, Jamie; Ivy, Dunbar; Miyamoto, Shelley; Shandas, Robin
2017-01-01
Background/Objectives The objective of this study was to evaluate the utility of circulating miRNAs as biomarkers of vascular function in pediatric pulmonary hypertension. Method Fourteen pediatric pulmonary arterial hypertension patients underwent simultaneous right heart catheterization (RHC) and blood biochemical analysis. Univariate and stepwise multivariate linear regression was used to identify and correlate measures of reactive and resistive afterload with circulating miRNA levels. Furthermore, circulating miRNA candidates that classified patients according to a 20% decrease in resistive afterload in response to oxygen (O2) or inhaled nitric oxide (iNO) were identified using receiver-operating curves. Results Thirty-two circulating miRNAs correlated with the pulmonary vascular resistance index (PVRi), pulmonary arterial distensibility, and PVRi decrease in response to O2 and/or iNO. Multivariate models, combining the predictive capability of multiple promising miRNA candidates, revealed a good correlation with resistive (r = 0.97, P2−tailed < 0.0001) and reactive (r = 0.86, P2−tailed < 0.005) afterloads. Bland-Altman plots showed that 95% of the differences between multivariate models and RHC would fall within 0.13 (mmHg−min/L)m2 and 0.0085/mmHg for resistive and reactive afterloads, respectively. Circulating miR-663 proved to be a good classifier for vascular responsiveness to acute O2 and iNO challenges. Conclusion This study suggests that circulating miRNAs may be biomarkers to phenotype vascular function in pediatric PAH. PMID:28819545
Ochi, H; Ikuma, I; Toda, H; Shimada, T; Morioka, S; Moriyama, K
1989-12-01
In order to determine whether isovolumic relaxation period (IRP) reflects left ventricular relaxation under different afterload conditions, 17 anesthetized, open chest dogs were studied, and the left ventricular pressure decay time constant (T) was calculated. In 12 dogs, angiotensin II and nitroprusside were administered, with the heart rate constant at 90 beats/min. Multiple linear regression analysis showed that the aortic dicrotic notch pressure (AoDNP) and T were major determinants of IRP, while left ventricular end-diastolic pressure was a minor determinant. Multiple linear regression analysis, correlating T with IRP and AoDNP, did not further improve the correlation coefficient compared with that between T and IRP. We concluded that correction of the IRP by AoDNP is not necessary to predict T from additional multiple linear regression. The effects of ascending aortic constriction or angiotensin II on IRP were examined in five dogs, after pretreatment with propranolol. Aortic constriction caused a significant decrease in IRP and T, while angiotensin II produced a significant increase in IRP and T. IRP was affected by the change of afterload. However, the IRP and T values were always altered in the same direction. These results demonstrate that IRP is substituted for T and it reflects left ventricular relaxation even in different afterload conditions. We conclude that IRP is a simple parameter easily used to evaluate left ventricular relaxation in clinical situations.
Use of an iPad App to simulate pressure-volume loops and cardiovascular physiology.
Leisman, Staci; Burkhoff, Daniel
2017-09-01
The purpose of this laboratory exercise is to model the changes in preload, afterload, and contractility on a simulated pressure-volume loop and to correlate those findings with common measurements of clinical cardiovascular physiology. Once students have modeled these changes on a healthy heart, the students are asked to look at a simulated case of cardiogenic shock. Effects on preload, contractility, and afterload are explored, as well as the hemodynamic effects of a number of student-suggested treatment strategies. Copyright © 2017 the American Physiological Society.
Human factors evaluation of remote afterloading brachytherapy. Volume 2, Function and task analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callan, J.R.; Gwynne, J.W. III; Kelly, T.T.
1995-05-01
A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the first phase of the project, which involved an extensive function and task analysis of RAB. This analysis identified the functions and tasks in RAB, made preliminary estimates of the likelihood of human error in each task, and determined the skills needed to perform each RAB task.more » The findings of the function and task analysis served as the foundation for the remainder of the project, which evaluated four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training and qualifications of RAB staff; and organizational practices and policies. At its completion, the project identified and prioritized areas for recommended NRC and industry attention based on all of the evaluations and analyses.« less
Trinkl, J; Havlik, P; Mesana, T; Mitsui, N; Morita, S; Demunck, J L; Tourres, J L; Monties, J R
1993-01-01
Our ventricular assist device uses a valveless volumetric pump operating on the Maillard-Wankel rotary principle. It is driven by an electric motor and provides a semi pulsatile flow. At each cycle, blood is actively aspirated into the device, and overpumping results in collapse at the pump inlet. To prevent overpumping, it is necessary to ensure that pump intake does not exceed venous return. Poor long-term reliability rules out the use of current implantable pressure sensors for this purpose. To resolve this problem, we have developed a method of control based on monitoring of the intensity of electric current consumed by the motor. The method consists of real time monitoring of current intensity at the beginning of each pump cycle. A sudden change in intensity indicates underfilling, and motor speed is reduced to prevent collapse. The current consumed by the motor also depends on the afterload, but the form of the signal remains the same when afterload changes. After demonstrating the feasibility of this technique in a simulator, we are now testing it in animals. We were able to detect and prevent collapse due to overpumping by the cardiac assist device. This system also enables us to know the maximum possible assistance and to thus adapt assistance to the user.
Swift, Andrew J; Capener, Dave; Hammerton, Charlotte; Thomas, Steven M; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G
2015-01-01
Sex differences exist in both the prevalence and survival of patients with idiopathic pulmonary arterial hypertension (IPAH). Men are less frequently affected by the condition but have worse outcome as compared to females. We sought to characterise the sex related differences in right ventricular remodelling in age matched male and female patients with IPAH using cardiac magnetic resonance imaging (MRI). A case controlled pair-matched study was conducted with patients matched by age and sex. Steady state free precession (SSFP) MRI of the heart was performed at 1.5T. Cardiac volume, function and mass measurements were corrected for age, sex and BSA according to reference data. 40 age and sex matched patients with IPAH were identified. The mean age was 57 (SD 17) in both male and female cohorts. Men had proportionally lower right ventricular (RV) ejection fraction, RV stroke volume and LV stroke volume than females, p=0.028, p=0.007 and p=0.013, respectively. However, there was no significant difference in RV mass or haemodynamic indices of mPAP and PVR between males and females. Male patients with IPAH have proportionally worse RV function despite similar afterload. We hypothesise that adaptive remodelling of the RV in response to increased afterload in IPAH is more effective in females.
Swift, Andrew J.; Capener, Dave; Hammerton, Charlotte; Thomas, Steven M.; Elliot, Charlie; Condliffe, Robin; Wild, Jim M.; Kiely, David G.
2015-01-01
Purpose Sex differences exist in both the prevalence and survival of patients with idiopathic pulmonary arterial hypertension (IPAH). Men are less frequently affected by the condition but have worse outcome as compared to females. We sought to characterise the sex related differences in right ventricular remodelling in age matched male and female patients with IPAH using cardiac magnetic resonance imaging (MRI). Methods A case controlled pair-matched study was conducted with patients matched by age and sex. Steady state free precession (SSFP) MRI of the heart was performed at 1.5T. Cardiac volume, function and mass measurements were corrected for age, sex and BSA according to reference data. Results 40 age and sex matched patients with IPAH were identified. The mean age was 57 (SD 17) in both male and female cohorts. Men had proportionally lower right ventricular (RV) ejection fraction, RV stroke volume and LV stroke volume than females, p=0.028, p=0.007 and p=0.013, respectively. However, there was no significant difference in RV mass or haemodynamic indices of mPAP and PVR between males and females. Conclusion Male patients with IPAH have proportionally worse RV function despite similar afterload. We hypothesise that adaptive remodelling of the RV in response to increased afterload in IPAH is more effective in females. PMID:25996939
Gregory, Shaun D; Stevens, Michael C; Pauls, Jo P; Schummy, Emma; Diab, Sara; Thomson, Bruce; Anderson, Ben; Tansley, Geoff; Salamonsen, Robert; Fraser, John F; Timms, Daniel
2016-09-01
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Deufel, Christopher L; Mullins, John P; Zakhary, Mark J
2018-05-17
Nasobiliary high-dose-rate (HDR) brachytherapy has emerged as an effective tool to boost the radiation dose for patients with unresectable perihilar cholangiocarcinoma. This work describes a quality assurance (QA) tool for measuring the HDR afterloader's performance, including the transit dose, when the source wire travels through a tortuous nasobiliary catheter path. The nasobiliary QA device was designed to mimic the anatomical path of a nasobiliary catheter, including the nasal, stomach, duodenum, and bile duct loops. Two of these loops, the duodenum and bile duct loops, have adjustable radii of curvature, resulting in the ability to maximize stress on the source wire in transit. The device was used to measure the performance over time for the HDR afterloader and the differences between intraluminal catheter lots. An upper limit on the transit dose was also measured using radiochromic film and compared with a simple theoretical model. The QA device was capable of detecting performance variations among nasobiliary catheter lots and following radioactive source replacement. The transit dose from a nasobiliary treatment increased by up to one order of magnitude when the source wire encountered higher than normal friction. Three distinct travel speeds of the source wire were observed: 5.2, 17.4, and 54.7 cm/s. The maximum transit dose was 0.3 Gy at a radial distance of 5 mm from a 40.3 kU 192 Ir source. The source wire encounters substantially greater friction when it navigates through the nasobiliary brachytherapy catheter. A QA tool that mimics the nasal, stomach, duodenum, and bile duct loops may be used to evaluate transit dose and the afterloader's performance over time. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Joyce, William; Axelsson, Michael; Altimiras, Jordi; Wang, Tobias
2016-07-15
The ventricles of non-crocodilian reptiles are incompletely divided and provide an opportunity for mixing of oxygen-poor blood and oxygen-rich blood (intracardiac shunting). However, both cardiac morphology and in vivo shunting patterns exhibit considerable interspecific variation within reptiles. In the present study, we develop an in situ double-perfused heart approach to characterise the propensity and capacity for shunting in five reptile species: the turtle Trachemys scripta, the rock python Python sebae, the yellow anaconda Eunectes notaeus, the varanid lizard Varanus exanthematicus and the bearded dragon Pogona vitticeps To simulate changes in vascular bed resistance, pulmonary and systemic afterloads were independently manipulated and changes in blood flow distribution amongst the central outflow tracts were monitored. As previously demonstrated in Burmese pythons, rock pythons and varanid lizards exhibited pronounced intraventricular flow separation. As pulmonary or systemic afterload was raised, flow in the respective circulation decreased. However, flow in the other circulation, where afterload was constant, remained stable. This correlates with the convergent evolution of intraventricular pressure separation and the large intraventricular muscular ridge, which compartmentalises the ventricle, in these species. Conversely, in the three other species, the pulmonary and systemic flows were strongly mutually dependent, such that the decrease in pulmonary flow in response to elevated pulmonary afterload resulted in redistribution of perfusate to the systemic circuit (and vice versa). Thus, in these species, the muscular ridge appeared labile and blood could readily transverse the intraventricular cava. We conclude that relatively minor structural differences between non-crocodilian reptiles result in the fundamental changes in cardiac function. Further, our study emphasises that functionally similar intracardiac flow separation evolved independently in lizards (varanids) and snakes (pythons) from an ancestor endowed with the capacity for large intracardiac shunts. © 2016. Published by The Company of Biologists Ltd.
Zhang, Chengmin; Ohira, Masahiro; Iizuka, Takuo; Mikamo, Hiroshi; Nakagami, Takahiro; Suzuki, Masayo; Hirano, Keiichi; Takahashi, Mao; Shimizu, Kazuhiro; Sugiyama, Yuko; Yamaguchi, Takashi; Kawana, Hidetoshi; Endo, Kei; Saiki, Atsuhito; Oyama, Tomokazu; Kurosu, Takumi; Tomaru, Takanobu; Wang, Hongyu; Noike, Hirofumi; Shirai, Kohji
2013-01-01
The cardio-ankle vascular index (CAVI) has been proposed as a new noninvasive marker of arterial stiffness independent of blood pressure. Arterial stiffness is closely related to afterload, and elevated afterload aggravates heart failure. We hypothesized that CAVI is a potential marker of afterload in patients with heart failure. Thirty patients who were admitted because of acute heart failure were identified retrospectively from a review of clinical records. Plasma brain natriuretic peptide (BNP) levels, CAVI, cardiothoracic ratio (CTR), and echocardiographic parameters obtained during acute and chronic phases of heart failure were analyzed. Left ventricular ejection fraction (LVEF) increased significantly and CTR, BNP and CAVI decreased significantly after treatment of heart failure. A significant negative correlation was observed between the change in CAVI and change in LVEF in all subjects (r = -0.3272, P < 0.05). To examine the relationship between CAVI and LVEF, we divided the patients into two subgroups (∆CAVI < -0.5; CAVI decrease group, ∆CAVI ≥ -0.5; CAVI non-decrease group). CAVI was significantly improved after heart failure treatment only in the CAVI decrease group. LVEF decreased significantly in both groups, but the P value was smaller in the CAVI decrease group than in the CAVI non-decrease group. The change in LVEF correlated significantly with the change in CAVI in the CAVI decrease group (r = -0.4201, P < 0.05), whereas no significant correlation was found in the CAVI non-decrease group. CAVI correlates inversely with LVEF after heart failure treatment. Our results suggest that CAVI might partially reflect the afterload in patients with heart failure.
Cardiopulmonary physiology: why the heart and lungs are inextricably linked.
Verhoeff, Kevin; Mitchell, Jamie R
2017-09-01
Because the heart and lungs are confined within the thoracic cavity, understanding their interactions is integral for studying each system. Such interactions include changes in external constraint to the heart, blood volume redistribution (venous return), direct ventricular interaction (DVI), and left ventricular (LV) afterload. During mechanical ventilation, these interactions can be amplified and result in reduced cardiac output. For example, increased intrathoracic pressure associated with mechanical ventilation can increase external constraint and limit ventricular diastolic filling and, therefore, output. Similarly, high intrathoracic pressures can alter blood volume distribution and limit diastolic filling of both ventricles while concomitantly increasing pulmonary vascular resistance, leading to increased DVI, which may further limit LV filling. While LV afterload is generally considered to decrease with increased intrathoracic pressure, the question arises if the reduced LV afterload is primarily a consequence of a reduced LV preload. A thorough understanding of the interaction between the heart and lungs can be complicated but is essential for clinicians and health science students alike. In this teaching review, we have attempted to highlight the present understanding of certain salient aspects of cardiopulmonary physiology and pathophysiology, as well as provide a resource for multidisciplined health science educators and students. Copyright © 2017 the American Physiological Society.
Giannetta, Elisa; Feola, Tiziana; Gianfrilli, Daniele; Pofi, Riccardo; Dall'Armi, Valentina; Badagliacca, Roberto; Barbagallo, Federica; Lenzi, Andrea; Isidori, Andrea M
2014-10-20
The myocardial effects of phosphodiesterase type 5 inhibitors (PDE5i) have recently received consideration in several preclinical studies. The risk/benefit ratio in humans remains unclear. We performed a meta-analysis of randomized, placebo-controlled trials (RCTs) to evaluate the efficacy and safety of PDE5i on cardiac morphology and function. From March 2012 to December 2013 (update: May 2014), we searched English-language studies from MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and SCOPUS-selecting RCTs of continuous PDE5i administration that reported cardiovascular outcomes: cardiac geometry and performance, afterload, endothelial function and safety. The pooled estimate of a weighted mean difference between treatment and placebo was obtained for all outcomes using a random effects model. A test for heterogeneity was performed and the I2 statistic calculated. Overall, 1,622 subjects were treated, with 954 randomized to PDE5i and 772 to placebo in 24 RCTs. According to our analysis, sustained PDE5 inhibition produced: (1) an anti-remodeling effect by reducing cardiac mass (-12.21 g/m2, 95% confidence interval (CI): -18.85; -5.57) in subjects with left ventricular hypertrophy (LVH) and by increasing end-diastolic volume (5.00 mL/m2; 95% CI: 3.29; 6.71) in non-LVH patients; (2) an improvement in cardiac performance by increasing cardiac index (0.30 L/min/m2, 95% CI: 0.202; 0.406) and ejection fraction (3.56%, 95% CI: 1.79; 5.33). These effects are parallel to a decline of N-terminal-pro brain natriuretic peptide (NT-proBNP) in subjects with severe LVH (-486.7 pg/ml, 95% CI: -712; -261). PDE5i administration also produced: (3) no changes in afterload parameters and (4) an improvement in flow-mediated vasodilation (3.31%, 95% CI: 0.53; 6.08). Flushing, headache, epistaxis and gastric symptoms were the commonest side effects. This meta-analysis suggests for the first time that PDE5i have anti-remodeling properties and improve cardiac inotropism, independently of afterload changes, with a good safety profile. Given the reproducibility of the findings and tolerability across different populations, PDE5i could be reasonably offered to men with cardiac hypertrophy and early stage heart failure. Given the limited gender data, a larger trial on the sex-specific response to long-term PDE5i treatment is required.
Blaudszun, Grégoire; Morel, Denis R
2012-11-01
Pulmonary hypertension and associated pressure-overload right ventricular (RV) hypertrophy represent a tremendous challenge for the anesthesiologist, as optimal perioperative management is mandatory. However, the ideal anesthetic agent remains unknown because scientific evidence is lacking. Twenty-eight rats were randomly assigned to a control or a monocrotaline group (60 mg kg). Four weeks later, animals were anesthetized, instrumented with a RV conductance catheter, and underwent well-controlled dose-responses to isoflurane, desflurane, and sevoflurane inhalation (minimum alveolar concentrations 0.5, 1.0, 1.5). Compared with controls, rats injected with monocrotaline presented with RV hypertrophy, increased afterload, and contractility, without change in cardiac output. The ratio of pressures in the right over the left circulation increased. The halogenated volatiles differently altered hemodynamics. Sevoflurane reduced RV contractility (more than 50%) and the right over left pressures ratio increased (from 0.41 ± 0.08 [SD] to 0.82 ± 0.14; P < 0.0001) secondary to profound concomitant systemic vasodilation, demonstrating a critical pressure gradient between right and left circulations. Despite significantly higher RV systolic pressures and afterload, desflurane decreased RV contractility much less (<10%; P < 0.0001 vs. sevoflurane) and maintained the right over left pressures ratio at more favorable values (0.47 ± 0.07; P < 0.0001 vs. sevoflurane). Isoflurane presented intermediate effects. In the presence of pressure-overload RV hypertrophy, hemodynamics are better preserved under desflurane inhalation, whereas sevoflurane-and to a lesser extent isoflurane-cause large discrepancies on the left and right circulations, raising the right over left pressures ratio to critical levels despite a conserved cardiac output.
Murai, Daisuke; Yamada, Satoshi; Hayashi, Taichi; Okada, Kazunori; Nishino, Hisao; Nakabachi, Masahiro; Yokoyama, Shinobu; Abe, Ayumu; Ichikawa, Ayako; Ono, Kota; Kaga, Sanae; Iwano, Hiroyuki; Mikami, Taisei; Tsutsui, Hiroyuki
2017-05-01
Whether and how left ventricular (LV) strain and strain rate correlate with wall stress is not known. Furthermore, it is not determined whether strain or strain rate is less dependent on the afterload. In 41 healthy young adults, LV global peak strain and systolic peak strain rate in the longitudinal direction (LS and LSR, respectively) and circumferential direction (CS and CSR, respectively) were measured layer-specifically using speckle tracking echocardiography (STE) before and during a handgrip exercise. Among all the points before and during the exercise, all the STE parameters significantly correlated linearly with wall stress (LS: r = -0.53, p < 0.01, LSR: r = -0.28, p < 0.05, CS in the inner layer: r = -0.72, p < 0.01, CSR in the inner layer: r = -0.47, p < 0.01). Strain more strongly correlated with wall stress than strain rate (r = -0.53 for LS vs. r = -0.28 for LSR, p < 0.05; r = -0.72 for CS vs. r = -0.47 for CSR in the inner layer, p < 0.05), whereas the interobserver variability was similar between strain and strain rate (longitudinal 6.2 vs. 5.2 %, inner circumferential 4.8 vs. 4.7 %, mid-circumferential 7.9 vs. 6.9 %, outer circumferential 10.4 vs. 9.7 %), indicating that the differences in correlation coefficients reflect those in afterload dependency. It was thus concluded that LV strain and strain rate linearly and inversely correlated with wall stress in the longitudinal and circumferential directions, and strain more strongly depended on afterload than did strain rate. Myocardial shortening should be evaluated based on the relationships between these parameters and wall stress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santoro, J; Witten, M; Haas, J
Purpose: Brachytherapy has been the standard of care for cervical cancer for 100 years. The treatment can be administered using an HDR (high dose rate) remote afterloader with a {sup 192}Ir source in an outpatient setting, a PDR afterloader with a {sup 192}Ir source, or with LDR manually loaded or a remote afterloader utilizing {sup 192}Ir or {sup 137}Cs sources in an inpatient setting. The procedure involves the placement of a tandem and ovoid, tandem and ring, or tandem and cylinder applicator in an operating room setting with the patient under general anesthesia. Inaccuracies introduced into the process occurring betweenmore » placement of the applicator and actual delivery can introduce uncertainty into the actual dose delivered to the tumor and critical organs. In this study we seek to investigate the dosimetric difference between an SBRT-based radiotherapy boost and conventional Brachytherapy in treating cervical cancer. Methods: Five HDR tandem and ovoid patients were planned using the Brachyvision treatment planning system and treated in four fractions using the Varian Varisource afterloader (Varian Medical Systems). For the same cohort, the patient planning CTs were imported into Multiplan (Accuray Inc) and a dose/fractionation-equivalent CyberKnife SBRT plan was retrospectively generated. Dosimetric quantities such as target/CTV D90, V90, D2cc for rectum, bladder, and bowel were measured and compared between the two modalities. Results: The CTV D90 for the tandem and ovoid was 2540cGy (90.7%) and 3009cGy (107.5%) for the CyberKnife plan. The D2cc for the rectum, bladder, and bowel were 1576cGy, 1641cGy, and 996cGy for the tandem and ovoid and 1374cGy, 1564cGy, and 1547cGy for CyberKnife. Conclusion: The D2cc doses to critical structures are comparable in both modalities. The CTV coverage is far superior for the CyberKnife plan. The dose distribution for CyberKnife has the advantage of increased conformality and lower maximum CTV dose.« less
Automatic insulation resistance testing apparatus
Wyant, Francis J.; Nowlen, Steven P.; Luker, Spencer M.
2005-06-14
An apparatus and method for automatic measurement of insulation resistances of a multi-conductor cable. In one embodiment of the invention, the apparatus comprises a power supply source, an input measuring means, an output measuring means, a plurality of input relay controlled contacts, a plurality of output relay controlled contacts, a relay controller and a computer. In another embodiment of the invention the apparatus comprises a power supply source, an input measuring means, an output measuring means, an input switching unit, an output switching unit and a control unit/data logger. Embodiments of the apparatus of the invention may also incorporate cable fire testing means. The apparatus and methods of the present invention use either voltage or current for input and output measured variables.
49 CFR 236.590 - Pneumatic apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...
49 CFR 236.590 - Pneumatic apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...
A patient transfer apparatus between bed and stretcher.
Wang, Hongbo; Kasagami, Fumio
2008-02-01
This paper presents a patient transfer apparatus between bed and stretcher. This apparatus makes it possible for the nurse to move weak, injured, or paralyzed patient from bed to stretcher, or vice versa, alone. Moreover, the suffering, stress, and uneasy feeling of the patient can be alleviated. This paper describes the specification, mechanical design, control system, and motion control of the apparatus. A special devised mechanism is developed, and a new servo system is used in this control system. The control principle and algorithm of the new servo system are proposed, and the motion-control method and safety function of the apparatus are described. The experimental results and evaluation indicated the effectiveness of this system.
Apparatus for controlling system state based on unique identifiers
Drotning, William D.
2002-01-01
An apparatus allows workers to assert and release control over the energization of a system. The apparatus does not require the workers to carry any additional paraphernalia, and is not be easily defeated by other workers. Users asserting and releasing control present tokens uniquely identifying each user to a reader, and the apparatus prevents transition of the system to an undesired state until an appropriate number of users are currently asserting control. For example, a dangerous manufacturing robot can be prevented from energizing until all the users that have asserted control when entering the robot's controlled space have subsequently released control when leaving the robot's controlled space.
Hanada, Takashi; Katsuta, Shoichi; Yorozu, Atsunori; Maruyama, Koichi
2009-01-01
When using a HDR remote afterloading brachytherapy unit, results of treatment can be greatly influenced by both source position and treatment time. The purpose of this study is to obtain information on the source of the HDR remote afterloading unit, such as its position and time structure, with the use of a simple system consisting of a plastic scintillator block and a charge‐coupled device (CCD) camera. The CCD camera was used for recording images of scintillation luminescence at a fixed rate of 30 frames per second in real time. The source position and time structure were obtained by analyzing the recorded images. For a preset source‐step‐interval of 5 mm, the measured value of the source position was 5.0±1.0mm, with a pixel resolution of 0.07 mm in the recorded images. For a preset transit time of 30 s, the measured value was 30.0±0.6 s, when the time resolution of the CCD camera was 1/30 s. This system enabled us to obtain the source dwell time and movement time. Therefore, parameters such as I192r source position, transit time, dwell time, and movement time at each dwell position can be determined quantitatively using this plastic scintillator‐CCD camera system. PACS number: 87.53.Jw
Impact of aortic root size on left ventricular afterload and stroke volume.
Sahlén, Anders; Hamid, Nadira; Amanullah, Mohammed Rizwan; Fam, Jiang Ming; Yeo, Khung Keong; Lau, Yee How; Lam, Carolyn S P; Ding, Zee Pin
2016-07-01
The left ventricle (LV) ejects blood into the proximal aorta. Age and hypertension are associated with stiffening and dilation of the aortic root, typically viewed as indicative of adverse remodeling. Based on analytical considerations, we hypothesized that a larger aortic root should be associated with lower global afterload (effective arterial elastance, EA) and larger stroke volume (SV). Moreover, as antihypertensive drugs differ in their effect on central blood pressure, we examined the role of antihypertensive drugs for the relation between aortic root size and afterload. We studied a large group of patients (n = 1250; 61 ± 12 years; 78 % males; 64 % hypertensives) from a single-center registry with known or suspected coronary artery disease. Aortic root size was measured by echocardiography as the diameter of the tubular portion of the ascending aorta. LV outflow tract Doppler was used to record SV. In the population as a whole, after adjusting for key covariates in separate regression models, aortic root size was an independent determinant of both SV and EA. This association was found to be heterogeneous and stronger in patients taking a calcium channel blocker (CCB; 10.6 % of entire population; aortic root size accounted for 8 % of the explained variance of EA). Larger aortic root size is an independent determinant of EA and SV. This association was heterogeneous and stronger in patients on CCB therapy.
TU-C-201-01: Clinical Implementation of HDR: A New User’s Perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Hallaq, H.
2015-06-15
Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for eachmore » institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.« less
TU-C-201-00: Clinical Implementation of HDR Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for eachmore » institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.« less
Mosalaei, A; Mohammadianpanah, M; Omidvari, S; Ahmadloo, N
2006-01-01
This retrospective analysis aims to report results of patients with cancer of uterine cervix treated with external-beam radiotherapy (EBR) and high-dose rate (HDR) brachytherapy, using manual treatment planning. From 1975 to 1995, 237 patients with FIGO stages IIB-IVA and mean age of 54.31 years were treated. EBR dose to the whole pelvis was 50 Gy in 25 fractions. Brachytherapy with HDR after-loading cobalt source (Cathetron) was performed following EBR completion with a dose of 30 Gy in three weekly fractions of 10 Gy to point A. Survival, local control, and genitourinary and gastrointestinal complications were assessed. In a median follow-up of 60.2 months, the 10-year overall and disease-free survival rate was 62.4%. Local recurrence was seen in 12.2% of patients. Distant metastases to the lymph nodes, peritoneum, lung, liver, and bone occurred in 25.3% of patients. Less than 6% of patients experienced severe genitourinary and/or gastrointestinal toxicity that were relieved by surgical intervention. No treatment-related mortality was seen. This series suggests that 50 Gy to the whole pelvis together with three fractions of 10 Gy to point A with HDR brachytherapy is an effective fractionation schedule in the treatment of locally advanced cancer of cervix. To decrease the complications, newer devices and treatment planning may be beneficial.
TU-C-201-03: The Use of Checklists and Audit Tools for Safety and QA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prisciandaro, J.
Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for eachmore » institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.« less
Load dependence of left ventricular contraction and relaxation. Effects of caffeine.
Leite-Moreira, A F; Correia-Pinto, J; Gillebert, T C
1999-08-01
Load dependence of left ventricular (LV) contraction and relaxation was investigated at baseline and after alteration of intracellular calcium handling by caffeine. Afterload was increased by aortic clamp occlusions (n = 281) in anesthetized open-chest dogs (n = 7). Control and first heartbeat after the intervention were considered for analysis. Caffeine (50 mg/kg, iv) had no inotropic effect. The systolic LV pressure (LVP), developed in response to aortic occlusion, decreased as ejection proceeded and this pressure generating capacity was not affected by caffeine. Late-systolic aortic occlusions induced premature onset and accelerated rate of initial LVP fall at baseline and similarly after caffeine. Graded diastolic aortic occlusions induced systolic LVP elevations of various magnitudes. Smaller LVP elevations prolonged ejection and accelerated LVP fall, while larger elevations had opposite effects. The transition from acceleration to deceleration was observed at 83.1 +/- 1.1% of peak isovolumetric LVP at baseline and at lower loads, at 77.6 +/- 1.2%, after caffeine (p < 0.01). Isovolumetric heartbeats prolonged the time constant tau by 238 +/- 70% at baseline and only by 155 +/- 44% after caffeine (p < 0.01). The relaxation-systolic pressure relation, which describes afterload dependence of relaxation, was also modified by caffeine. Caffeine affected LV relaxation without altering contractility. As a consequence contraction-relaxation coupling was modified by caffeine. These results might help to understand load dependence of relaxation in conditions where intracellular calcium handling is altered.
Waste Water Treatment Apparatus and Methods
NASA Technical Reports Server (NTRS)
Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor); Littman, Howard (Inventor)
2014-01-01
An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.
Methods and apparatus for handling or treating particulate material
NASA Technical Reports Server (NTRS)
Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)
2009-01-01
An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.
A pig model of acute right ventricular afterload increase by hypoxic pulmonary vasoconstriction.
Knai, Kathrine; Skjaervold, Nils Kristian
2017-01-03
The aim of this study was to construct a non-invasive model for acute right ventricular afterload increase by hypoxic pulmonary vasoconstriction. Intact animal models are vital to improving our understanding of the pathophysiology of acute right ventricular failure. Acute right ventricular failure is caused by increased afterload of the right ventricle by chronic or acute pulmonary hypertension combined with regionally or globally reduced right ventricular contractile capacity. Previous models are hampered by their invasiveness; this is unfortunate as the pulmonary circulation is a low-pressure system that needs to be studied in closed chest animals. Hypoxic pulmonary vasoconstriction is a mechanism that causes vasoconstriction in alveolar vessels in response to alveolar hypoxia. In this study we explored the use of hypoxic pulmonary vasoconstriction as a means to increase the pressure load on the right ventricle. Pulmonary hypertension was induced by lowering the FiO 2 to levels below the physiological range in eight anesthetized and mechanically ventilated pigs. The pigs were monitored with blood pressure measurements and blood gases. The mean pulmonary artery pressures (mPAP) of the animals increased from 18.3 (4.2) to 28.4 (4.6) mmHg and the pulmonary vascular resistance (PVR) from 254 (76) dyns/cm 5 to 504 (191) dyns/cm 5 , with a lowering of FiO 2 from 0.30 to 0.15 (0.024). The animals' individual baseline mPAPs varied substantially as did their response to hypoxia. The reduced FiO 2 level yielded an overall lowering in oxygen offer, but the global oxygen consumption was unaltered. We showed in this study that the mPAP and the PVR could be raised by approximately 100% in the study animals by lowering the FiO 2 from 0.30 to 0.15 (0.024). We therefore present a novel method for minimally invasive (closed chest) right ventricular afterload manipulations intended for future studies of acute right ventricular failure. The method should in theory be reversible, although this was not studied in this work.
Afterload mismatch in aortic and mitral valve disease: implications for surgical therapy.
Ross, J
1985-04-01
In the management of patients with valvular heart disease, an understanding of the effects of altered loading conditions on the left ventricle is important in reaching a proper decision concerning the timing of corrective operation. In acquired valvular aortic stenosis, concentric hypertrophy generally maintains left ventricular chamber size and ejection fraction within normal limits, but in late stage disease function can deteriorate as preload reserve is lost and aortic stenosis progresses. In this setting, even when the ejection fraction is markedly reduced (less than 25%), it can improve to normal after aortic valve replacement, suggesting that afterload mismatch rather than irreversibly depressed myocardial contractility was responsible for left ventricular failure. Therefore, patients with severe aortic stenosis and symptoms should not be denied operation because of impaired cardiac function. In chronic severe aortic and mitral regurgitation, operation is generally recommended when symptoms are present, but whether to recommend operation to prevent irreversible myocardial damage in patients with few or no symptoms has remained controversial. In aortic regurgitation, left ventricular function generally improves postoperatively, even if it is moderately impaired preoperatively, indicating correction of afterload mismatch. Most such patients can be carefully followed by echocardiography. However, in some patients, severe left ventricular dysfunction fails to improve postoperatively. Therefore, when echocardiographic studies in the patient with severe aortic regurgitation show an ejection fraction of less than 40% (fractional shortening less than 25%) plus enlarging left ventricular end-diastolic diameter (approaching 38 mm/m2 body surface area) and end-systolic diameter (approaching 50 mm or 26 mm/m2), confirmation of these findings by cardiac catheterization and consideration of operation are advisable even in patients with minimal symptoms. In chronic mitral regurgitation, maintenance of a normal ejection fraction can mask depressed myocardial contractility. Pre- and postoperative studies in such patients have shown a poor clinical result after mitral valve replacement, associated with a sharp decrease in the ejection fraction after operation. This response appears to reflect unmasking of decreased myocardial contractility by mitral valve replacement, with ejection of the total stroke volume into the high impedance of the aorta (afterload mismatch produced by operation).(ABSTRACT TRUNCATED AT 400 WORDS)
Modular droplet actuator drive
NASA Technical Reports Server (NTRS)
Pollack, Michael G. (Inventor); Paik, Philip (Inventor)
2011-01-01
A droplet actuator drive including a detection apparatus for sensing a property of a droplet on a droplet actuator; circuitry for controlling the detection apparatus electronically coupled to the detection apparatus; a droplet actuator cartridge connector arranged so that when a droplet actuator cartridge electronically is coupled thereto: the droplet actuator cartridge is aligned with the detection apparatus; and the detection apparatus can sense the property of the droplet on a droplet actuator; circuitry for controlling a droplet actuator coupled to the droplet actuator connector; and the droplet actuator circuitry may be coupled to a processor.
Howell, W.D.
1957-08-20
An apparatus for automatically recording the results of counting operations on trains of electrical pulses is described. The disadvantages of prior devices utilizing the two common methods of obtaining the count rate are overcome by this apparatus; in the case of time controlled operation, the disclosed system automatically records amy information stored by the scaler but not transferred to the printer at the end of the predetermined time controlled operations and, in the case of count controlled operation, provision is made to prevent a weak sample from occupying the apparatus for an excessively long period of time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teshima, Teruki, E-mail: teshima@sahs.med.osaka-u.ac.j; Numasaki, Hodaka; Shibuya, Hitoshi
2010-12-01
Purpose: To evaluate the ongoing structure of radiation oncology in Japan in terms of equipment, personnel, patient load, and geographic distribution to identify and improve any deficiencies. Methods and Materials: A questionnaire-based national structure survey was conducted from March to December 2008 by the Japanese Society of Therapeutic Radiology and Oncology (JASTRO). These data were analyzed in terms of the institutional stratification of the Patterns of Care Study. Results: The total numbers of new cancer patients and total cancer patients (new and repeat) treated with radiation in 2007 were estimated at 181,000 and 218,000, respectively. There were 807 linear accelerator,more » 15 telecobalt, 46 Gamma Knife, 45 {sup 60}Co remote-controlled after-loading, and 123 {sup 192}Ir remote-controlled after-loading systems in actual use. The linear accelerator systems used dual-energy function in 539 units (66.8%), three-dimensional conformal radiation therapy in 555 (68.8%), and intensity-modulated radiation therapy in 235 (29.1%). There were 477 JASTRO-certified radiation oncologists, 826.3 full-time equivalent (FTE) radiation oncologists, 68.4 FTE medical physicists, and 1,634 FTE radiation therapists. The number of interstitial radiotherapy (RT) administrations for prostate, stereotactic body radiotherapy, and intensity-modulated radiation therapy increased significantly. Patterns of Care Study stratification can clearly identify the maturity of structures based on their academic nature and caseload. Geographically, the more JASTRO-certified physicians there were in a given area, the more RT tended to be used for cancer patients. Conclusions: The Japanese structure has clearly improved during the past 17 years in terms of equipment and its use, although a shortage of personnel and variations in maturity disclosed by Patterns of Care Study stratification were still problematic in 2007.« less
Licker, Marc; Ellenberger, Christoph; Sierra, Jorge; Christenson, Jan; Diaper, John; Morel, Denis
2005-03-01
Preoperative acute normovolemic hemodilution induces an increase in circulatory output that is thought to be limited in patients with cardiac diseases. Using multiple-plane transesophageal echocardiography, we investigated the mechanisms of cardiovascular adaptation during acute normovolemic hemodilution in patients with severe coronary artery disease. Prospective case-control study. Operating theater in a university hospital. Consecutive patients treated with beta-blockers, scheduled to undergo coronary artery bypass (n = 50). After anesthesia induction, blood withdrawal and isovolemic exchange with iso-oncotic starch (1:1.15 ratio) to achieve a hematocrit value of 28%. In addition to heart rate and intravascular pressures, echocardiographic recordings were obtained before and after acute normovolemic hemodilution to assess cardiac preload, afterload, and contractility. In a control group, not subjected to acute normovolemic hemodilution, hemodynamic variables remained stable during a 20-min anesthesia period. Following acute normovolemic hemodilution, increases in cardiac stroke volume (+28 +/- 4%; mean +/- sd) were correlated with increases in central venous pressure (+2.0 +/- 1.3 mm Hg; R = .56) and in left ventricular end-diastolic area (+18 +/- 5%, R = .39). The unchanged left ventricular end-systolic wall stress and preload-adjusted maximal power indicated that neither left ventricular afterload nor contractility was affected by acute normovolemic hemodilution. Diastolic left ventricular filling abnormalities (15 of 22 cases) improved in 11 patients and were stable in the remaining four patients. Despite reduction in systemic oxygen delivery (-20.5 +/- 7%, p < .05), there was no evidence for myocardial ischemia (electrocardiogram, left ventricular wall motion abnormalities). In anesthetized patients with coronary artery disease, moderate acute normovolemic hemodilution did not compromise left ventricular systolic and diastolic function. Lowering blood viscosity resulted in increased stroke volume that was mainly related to increased venous return and higher cardiac preload.
Reda, Ibrahim
2013-10-29
Implementations of the present disclosure involve an apparatus and method to measure the long-wave irradiance of the atmosphere or long-wave source. The apparatus may involve a thermopile, a concentrator and temperature controller. The incoming long-wave irradiance may be reflected from the concentrator to a thermopile receiver located at the bottom of the concentrator to receive the reflected long-wave irradiance. In addition, the thermopile may be thermally connected to a temperature controller to control the device temperature. Through use of the apparatus, the long-wave irradiance of the atmosphere may be calculated from several measurements provided by the apparatus. In addition, the apparatus may provide an international standard of pyrgeometers' calibration that is traceable back to the International System of Units (SI) rather than to a blackbody atmospheric simulator.
An accelerated exposure and testing apparatus for building joint sealants
NASA Astrophysics Data System (ADS)
White, C. C.; Hunston, D. L.; Tan, K. T.; Hettenhouser, J.; Garver, J. D.
2013-09-01
The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.
An accelerated exposure and testing apparatus for building joint sealants.
White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D
2013-09-01
The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teshima, Teruki; Numasaki, Hodaka; Shibuya, Hitoshi
2008-09-01
Purpose: To evaluate the structure of radiation oncology in Japan in terms of equipment, personnel, patient load, and geographic distribution to identify and improve any deficiencies. Methods and Materials: A questionnaire-based national structure survey was conducted between March 2006 and February 2007 by the Japanese Society of Therapeutic Radiology and Oncology. These data were analyzed in terms of the institutional stratification of the Patterns of Care Study. Results: The total numbers of new cancer patients and total cancer patients (new and repeat) treated with radiotherapy in 2005 were estimated at approximately 162,000 and 198,000, respectively. In actual use were 765more » linear accelerators, 11 telecobalt machines, 48 GammaKnife machines, 64 {sup 60}Co remote-controlled after-loading systems, and 119 {sup 192}Ir remote-controlled after-loading systems. The linear accelerator systems used dual-energy function in 498 systems (65%), three-dimensional conformal radiotherapy in 462 (60%), and intensity-modulated radiotherapy in 170 (22%). There were 426 Japanese Society of Therapeutic Radiology and Oncology-certified radiation oncologists, 774 full-time equivalent radiation oncologists, 117 medical physicists, and 1,635 radiation therapists. Geographically, a significant variation was found in the use of radiotherapy, from 0.9 to 2.1 patients/1,000 population. The annual patient load/FTE radiation oncologist was 247, exceeding the Blue Book guidelines level. Patterns of Care Study stratification can clearly discriminate the maturity of structures according to their academic nature and caseload. Conclusions: The Japanese structure has clearly improved during the past 15 years in terms of equipment and its use, although the shortage of manpower and variations in maturity disclosed by this Patterns of Care Study stratification remain problematic. These constitute the targets for nationwide improvement in quality assurance and quality control.« less
Vasodilators in Acute Heart Failure: Review of the Latest Studies.
Levy, Phillip D; Laribi, Said; Mebazaa, Alexandre
2014-06-01
Vasodilators play an important role in the management of acute heart failure, particularly when increased afterload is the precipitating cause of decompensation. The time-honored approach to afterload reduction has been largely focused on use of intravenous nitrovasodilators and, when properly dosed, this class of agents does provide substantial symptom relief for patients with acute hypertensive heart failure. Despite this, nitrovasodilators have never been shown to diminish mortality or provide any post-discharge outcome benefit leading to an on-going search for viable and more effective alternatives. While no new vasodilators have been approved for use in acute heart failure since nesiritide more than a decade ago, a number of novel agents have been developed, with some showing significant promise in recent clinical trials. In this review, we summarize the latest study data as it relates to vasodilator therapy and provide a glimpse into the not too distant future state of acute heart failure care.
Apparatus and method for gas turbine active combustion control system
NASA Technical Reports Server (NTRS)
Knobloch, Aaron (Inventor); Mancini, Alfred Albert (Inventor); Myers, William J. (Inventor); Fortin, Jeffrey B. (Inventor); Umeh, Chukwueloka (Inventor); Kammer, Leonardo C. (Inventor); Shah, Minesh (Inventor)
2011-01-01
An Active Combustion Control System and method provides for monitoring combustor pressure and modulating fuel to a gas turbine combustor to prevent combustion dynamics and/or flame extinguishments. The system includes an actuator, wherein the actuator periodically injects pulsed fuel into the combustor. The apparatus also includes a sensor connected to the combustion chamber down stream from an inlet, where the sensor generates a signal detecting the pressure oscillations in the combustor. The apparatus controls the actuator in response to the sensor. The apparatus prompts the actuator to periodically inject pulsed fuel into the combustor at a predetermined sympathetic frequency and magnitude, thereby controlling the amplitude of the pressure oscillations in the combustor by modulating the natural oscillations.
Whitaker, Morgan E; Nair, Vineet; Sinari, Shripad; Dherange, Parinita A; Natarajan, Balaji; Trutter, Lindsey; Brittain, Evan L; Hemnes, Anna R; Austin, Eric D; Patel, Kumar; Black, Stephen M; Garcia, Joe G N; Yuan Md PhD, Jason X; Vanderpool, Rebecca R; Rischard, Franz; Makino, Ayako; Bedrick, Edward J; Desai, Ankit A
2018-06-01
Diabetes mellitus is associated with left ventricular hypertrophy and dysfunction. Parallel studies have also reported associations between diabetes mellitus and right ventricular dysfunction and reduced survival in patients with pulmonary arterial hypertension. However, the impact of diabetes mellitus on the pulmonary vasculature has not been well characterized. We hypothesized that diabetes mellitus and hyperglycemia could specifically influence right ventricular afterload and remodeling in patients with Group I pulmonary arterial hypertension, providing a link to their known susceptibility to right ventricular dysfunction. Using an adjusted model for age, sex, pulmonary vascular resistance, and medication use, associations of fasting blood glucose, glycated hemoglobin, and the presence of diabetes mellitus were evaluated with markers of disease severity in 162 patients with pulmonary arterial hypertension. A surrogate measure of increased pulmonary artery stiffness, elevated pulmonary arterial elastance (P = .012), along with reduced log(pulmonary artery capacitance) (P = .006) were significantly associated with the presence of diabetes mellitus in patients with pulmonary arterial hypertension in a fully adjusted model. Similar associations between pulmonary arterial elastance and capacitance were noted with both fasting blood glucose and glycated hemoglobin. Furthermore, right ventricular wall thickness on echocardiography was greater in pulmonary arterial hypertension patients with diabetes, supporting the link between right ventricular remodeling and diabetes. Cumulatively, these data demonstrate that an increase in right ventricular afterload, beyond pulmonary vascular resistance alone, may influence right ventricular remodeling and provide a mechanistic link between the susceptibility to right ventricular dysfunction in patients with both diabetes mellitus and pulmonary arterial hypertension. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Anthony; Ravi, Ananth
2014-08-15
High dose rate (HDR) remote afterloading brachytherapy involves sending a small, high-activity radioactive source attached to a cable to different positions within a hollow applicator implanted in the patient. It is critical that the source position within the applicator and the dwell time of the source are accurate. Daily quality assurance (QA) tests of the positional and dwell time accuracy are essential to ensure that the accuracy of the remote afterloader is not compromised prior to patient treatment. Our centre has developed an automated, video-based QA system for HDR brachytherapy that is dramatically superior to existing diode or film QAmore » solutions in terms of cost, objectivity, positional accuracy, with additional functionalities such as being able to determine source dwell time and transit time of the source. In our system, a video is taken of the brachytherapy source as it is sent out through a position check ruler, with the source visible through a clear window. Using a proprietary image analysis algorithm, the source position is determined with respect to time as it moves to different positions along the check ruler. The total material cost of the video-based system was under $20, consisting of a commercial webcam and adjustable stand. The accuracy of the position measurement is ±0.2 mm, and the time resolution is 30 msec. Additionally, our system is capable of robustly verifying the source transit time and velocity (a test required by the AAPM and CPQR recommendations), which is currently difficult to perform accurately.« less
46 CFR 195.30-15 - Self-contained breathing apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...
46 CFR 195.30-15 - Self-contained breathing apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...
27 CFR 29.55 - Registry of stills and distilling apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... distilling apparatus. 29.55 Section 29.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Registry of stills and distilling apparatus. (a) General. Every person having possession, custody, or control of any still or distilling apparatus set up shall, immediately on its being set up, register the...
27 CFR 29.55 - Registry of stills and distilling apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... distilling apparatus. 29.55 Section 29.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Registry of stills and distilling apparatus. (a) General. Every person having possession, custody, or control of any still or distilling apparatus set up shall, immediately on its being set up, register the...
46 CFR 96.30-15 - Self-contained breathing apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...
46 CFR 169.736 - Self-contained breathing apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...
46 CFR 96.30-15 - Self-contained breathing apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...
46 CFR 169.736 - Self-contained breathing apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...
Method and apparatus for injecting a substance into the bloodstream of a subject
Lambrecht, Richard M.; Bennett, Gerald W.; Duncan, Charles C.; Ducote, Louis W.
1983-10-18
An apparatus and method for injecting a substance, such as a radiopharmaceutical, into the bloodstream of a subject. The apparatus comprises an injection means, such as a servo controlled syringe, a means for measuring the concentration of that substance in the subject's bloodstream, and means for controlling the injection in response to the measurement so that the concentration of the substance follows a predetermined function of time. The apparatus of the subject invention functions to inject a substance into a subject's bloodstream at a rate controlled by an error signal proportional to the difference between the concentration of the substance in the subject's bloodstream and the predetermined function.
Method and apparatus for injecting a substance into the bloodstream of a subject
Lambrecht, R.M.; Bennett, G.W.; Duncan, C.C.; Ducote, L.W.
1983-10-18
An apparatus and method is disclosed for injecting a substance, such as a radiopharmaceutical, into the bloodstream of a subject. The apparatus comprises an injection means, such as a servo controlled syringe, a means for measuring the concentration of that substance in the subject's bloodstream, and means for controlling the injection in response to the measurement so that the concentration of the substance follows a predetermined function of time. The apparatus of the subject invention functions to inject a substance into a subject's bloodstream at a rate controlled by an error signal proportional to the difference between the concentration of the substance in the subject's bloodstream and the predetermined function. 2 figs.
System and method for magnetic current density imaging at ultra low magnetic fields
Espy, Michelle A.; George, John Stevens; Kraus, Robert Henry; Magnelind, Per; Matlashov, Andrei Nikolaevich; Tucker, Don; Turovets, Sergei; Volegov, Petr Lvovich
2016-02-09
Preferred systems can include an electrical impedance tomography apparatus electrically connectable to an object; an ultra low field magnetic resonance imaging apparatus including a plurality of field directions and disposable about the object; a controller connected to the ultra low field magnetic resonance imaging apparatus and configured to implement a sequencing of one or more ultra low magnetic fields substantially along one or more of the plurality of field directions; and a display connected to the controller, and wherein the controller is further configured to reconstruct a displayable image of an electrical current density in the object. Preferred methods, apparatuses, and computer program products are also disclosed.
Apparatus for coating and impregnating filament with resin
Robinson, S.C.; Pollard, R.E.
1986-12-17
The present invention is directed to an apparatus for evenly coating and impregnating a filament with binder material. Dimension control and repeatability of the coating and impregnating characteristics are obtained with the apparatus.
Remotely controlled sensor apparatus for use in dig-face characterization system
Josten, N.E.; Svoboda, J.M.
1999-05-25
A remotely controlled sensor platform apparatus useful in a dig-face characterization system is deployed from a mobile delivery device such as standard heavy construction equipment. The sensor apparatus is designed to stabilize sensors against extraneous motions induced by heavy equipment manipulations or other outside influences, and includes a terrain sensing and sensor elevation control system to maintain the sensors in close ground proximity. The deployed sensor apparatus is particularly useful in collecting data in work environments where human access is difficult due to the presence of hazardous conditions, rough terrain, or other circumstances that prevent efficient data collection by conventional methods. Such work environments include hazardous waste sites, unexploded ordnance sites, or construction sites. Data collection in these environments by utilizing the deployed sensor apparatus is desirable in order to protect human health and safety, or to assist in planning daily operations to increase efficiency. 13 figs.
Remotely controlled sensor apparatus for use in dig-face characterization system
Josten, Nicholas E.; Svoboda, John M.
1999-01-01
A remotely controlled sensor platform apparatus useful in a dig-face characterization system is deployed from a mobile delivery device such as standard heavy construction equipment. The sensor apparatus is designed to stabilize sensors against extraneous motions induced by heavy equipment manipulations or other outside influences, and includes a terrain sensing and sensor elevation control system to maintain the sensors in close ground proximity. The deployed sensor apparatus is particularly useful in collecting data in work environments where human access is difficult due to the presence of hazardous conditions, rough terrain, or other circumstances that prevent efficient data collection by conventional methods. Such work environments include hazardous waste sites, unexploded ordnance sites, or construction sites. Data collection in these environments by utilizing the deployed sensor apparatus is desirable in order to protect human health and safety, or to assist in planning daily operations to increase efficiency.
Surface control bent sub for directional drilling of petroleum wells
Russell, Larry R.
1986-01-01
Directional drilling apparatus for incorporation in a drill string, wherein a lower apparatus section is angularly deviated from vertical by cam action and wherein rotational displacement of the angularly deviated apparatus section is overcome by additional cam action, the apparatus being operated by successive increases and decreases of internal drill string pressure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... measurement of radioactivity; and (D) Radiation biology; and (ii) 500 hours of work experience, under the... section, and has achieved a level of competency sufficient to function independently as an authorized user...
System, Apparatus, and Method for Active Debris Removal
NASA Technical Reports Server (NTRS)
Hickey, Christopher J. (Inventor); Spehar, Peter T. (Inventor); Griffith, Sr., Anthony D. (Inventor); Kohli, Rajiv (Inventor); Burns, Susan H. (Inventor); Gruber, David J. (Inventor); Lee, David E. (Inventor); Robinson, Travis M. (Inventor); Damico, Stephen J. (Inventor); Smith, Jason T. (Inventor)
2017-01-01
Systems, apparatuses, and methods for removal of orbital debris are provided. In one embodiment, an apparatus includes a spacecraft control unit configured to guide and navigate the apparatus to a target. The apparatus also includes a dynamic object characterization unit configured to characterize movement, and a capture feature, of the target. The apparatus further includes a capture and release unit configured to capture a target and deorbit or release the target. The collection of these apparatuses is then employed as multiple, independent and individually operated vehicles launched from a single launch vehicle for the purpose of disposing of multiple debris objects.
Apparatus and process for controlling fluidized beds
Rehmat, Amirali G.; Patel, Jitendra G.
1985-10-01
An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.
Apparatus for controlling fluidized beds
Rehmat, Amirali G.; Patel, Jitendra G.
1987-05-12
An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.
Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)
NASA Technical Reports Server (NTRS)
Pantalos, George M.; Sharp, M. Keith; Woodruff, Stewart J.; Lorange, Richard D.; Bennett, Thomas E.; Sojka, Jan J.; Lemon, Mark W.
1993-01-01
The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.
Automated hybridization/imaging device for fluorescent multiplex DNA sequencing
Weiss, R.B.; Kimball, A.W.; Gesteland, R.F.; Ferguson, F.M.; Dunn, D.M.; Di Sera, L.J.; Cherry, J.L.
1995-11-28
A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, the enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots. 9 figs.
Automated hybridization/imaging device for fluorescent multiplex DNA sequencing
Weiss, Robert B.; Kimball, Alvin W.; Gesteland, Raymond F.; Ferguson, F. Mark; Dunn, Diane M.; Di Sera, Leonard J.; Cherry, Joshua L.
1995-01-01
A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, then an enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots.
NASA Technical Reports Server (NTRS)
Ollendorf, S. (Inventor)
1979-01-01
An apparatus for maintaining a heat dissipating load at a substantially constant temperature, and more particularly, to such an apparatus where in variable conductance heat pipes control the radiating area of a radiator is described.
Self-contained cryogenic gas sampling apparatus and method
McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.
1996-03-26
Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.
Method and apparatus for controlling carrier envelope phase
Chang, Zenghu [Manhattan, KS; Li, Chengquan [Sunnyvale, CA; Moon, Eric [Manhattan, KS
2011-12-06
A chirped pulse amplification laser system. The system generally comprises a laser source, a pulse modification apparatus including first and second pulse modification elements separated by a separation distance, a positioning element, a measurement device, and a feedback controller. The laser source is operable to generate a laser pulse and the pulse modification apparatus operable to modify at least a portion of the laser pulse. The positioning element is operable to reposition at least a portion of the pulse modification apparatus to vary the separation distance. The measurement device is operable to measure the carrier envelope phase of the generated laser pulse and the feedback controller is operable to control the positioning element based on the measured carrier envelope phase to vary the separation distance of the pulse modification elements and control the carrier envelope phase of laser pulses generated by the laser source.
Self-contained cryogenic gas sampling apparatus and method
McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.
1996-01-01
Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.
An automatic experimental apparatus to study arm reaching in New World monkeys.
Yin, Allen; An, Jehi; Lehew, Gary; Lebedev, Mikhail A; Nicolelis, Miguel A L
2016-05-01
Several species of the New World monkeys have been used as experimental models in biomedical and neurophysiological research. However, a method for controlled arm reaching tasks has not been developed for these species. We have developed a fully automated, pneumatically driven, portable, and reconfigurable experimental apparatus for arm-reaching tasks suitable for these small primates. We have utilized the apparatus to train two owl monkeys in a visually-cued arm-reaching task. Analysis of neural recordings demonstrates directional tuning of the M1 neurons. Our apparatus allows automated control, freeing the experimenter from manual experiments. The presented apparatus provides a valuable tool for conducting neurophysiological research on New World monkeys. Copyright © 2016. Published by Elsevier B.V.
Method and apparatus for controlling electroslag remelting
Maguire, Michael C.; Zanner, Frank J.; Damkroger, Brian K.; Miszkiel, Mark E.; Aronson, Eugene A.
1994-01-01
Method and apparatus for controlling electrode immersion depth in an electroslag remelting furnace. The phase difference of the alternating current circuit established in the furnace is calculated in real time and employed to more accurately control immersion depth than possible with voltage-swing systems.
Balanced bridge feedback control system
NASA Technical Reports Server (NTRS)
Lurie, Boris J. (Inventor)
1990-01-01
In a system having a driver, a motor, and a mechanical plant, a multiloop feedback control apparatus for controlling the movement and/or positioning of a mechanical plant, the control apparatus has a first local bridge feedback loop for feeding back a signal representative of a selected ratio of voltage and current at the output driver, and a second bridge feedback loop for feeding back a signal representative of a selected ratio of force and velocity at the output of the motor. The control apparatus may further include an outer loop for feeding back a signal representing the angular velocity and/or position of the mechanical plant.
Methods and apparatus for controlling rotary machines
Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Barnes, Gary R [Delanson, NY; Fric, Thomas Frank [Greer, SC; Lyons, James Patrick Francis [Niskayuna, NY; Pierce, Kirk Gee [Simpsonville, SC; Holley, William Edwin [Greer, SC; Barbu, Corneliu [Guilderland, NY
2009-09-01
A control system for a rotary machine is provided. The rotary machine has at least one rotating member and at least one substantially stationary member positioned such that a clearance gap is defined between a portion of the rotating member and a portion of the substantially stationary member. The control system includes at least one clearance gap dimension measurement apparatus and at least one clearance gap adjustment assembly. The adjustment assembly is coupled in electronic data communication with the measurement apparatus. The control system is configured to process a clearance gap dimension signal and modulate the clearance gap dimension.
Thermal energy storage apparatus, controllers and thermal energy storage control methods
Hammerstrom, Donald J.
2016-05-03
Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.
Method and apparatus for controlling gas evolution from chemical reactions
Skorpik, James R.; Dodson, Michael G.
1999-01-01
The present invention is directed toward monitoring a thermally driven gas evolving chemical reaction with an acoustic apparatus. Signals from the acoustic apparatus are used to control a heater to prevent a run-away condition. A digestion module in combination with a robotic arm further automate physical handling of sample material reaction vessels. The invention is especially useful for carrying out sample procedures defined in EPA Methods SW-846.
Apparatus for high flux photocatalytic pollution control using a rotating fluidized bed reactor
Tabatabaie-Raissi, Ali; Muradov, Nazim Z.; Martin, Eric
2003-06-24
An apparatus based on optimizing photoprocess energetics by decoupling of the process energy efficiency from the DRE for target contaminants. The technique is applicable to both low- and high-flux photoreactor design and scale-up. An apparatus for high-flux photocatalytic pollution control is based on the implementation of multifunctional metal oxide aerogels and other media in conjunction with a novel rotating fluidized particle bed reactor.
Viscous Energy Loss in the Presence of Abnormal Aortic Flow
Barker, A.J.; van Ooij, P.; Bandi, K.; Garcia, J.; Albaghdadi, M.; McCarthy, P.; Bonow, R. O.; Carr, J.; Collins, J.; Malaisrie, C.; Markl, M.
2014-01-01
Purpose To present a theoretical basis for noninvasively characterizing in vivo fluid-mechanical energy losses, and to apply it in a pilot study of patients known to express abnormal aortic flow patterns. Methods 4D flow MRI was used to characterize laminar viscous energy losses in the aorta of normal controls (n=12, age=37±10), patients with aortic dilation (n=16, age=52±8), and patients with aortic valve stenosis matched for age and aortic size (n=14, age=46±15), using a relationship between the 3D velocity field and viscous energy dissipation. Results Viscous energy loss was significantly elevated in the thoracic aorta for patients with dilated aorta (3.6±1.3 mW, p=0.024) and patients with aortic stenosis (14.3±8.2 mW, p<0.001) compared to healthy volunteers (2.3±0.9 mW). The same pattern of significant differences were seen in the ascending aorta, where viscous energy losses in patients with dilated aortas (2.2±1.1 mW, p=0.021) and patients with aortic stenosis (10.9±6.8 mW, p<0.001) were elevated compared to healthy volunteers (1.2±0.6 mW). Conclusion This technique provides a capability to quantify the contribution of abnormal laminar blood flow to increased ventricular afterload. In this pilot study, viscous energy loss in patient cohorts was significantly elevated and indicates that cardiac afterload is increased due to abnormal flow. PMID:24122967
Ntalianis, Argyrios S; Drakos, Stavros G; Charitos, Christos; Dolou, Paraskevi; Pierrakos, Charalampos N; Terrovitis, John V; Papaioannou, Theodoros; Charitos, Efstratios; Nanas, John N
2008-01-01
The present experimental study compared the effectiveness of counterpulsation provided by the intra-aortic balloon pump (IABP) versus that of a nonpulsatile, radial-flow centrifugal pump (CFP) in rapidly worsening acute heart failure (HF). Eighteen pigs were included in the study. After the induction of acute moderate HF, circulatory support was randomly provided with either the IABP or CFP. No significant change in cardiac output (CO) and mean aortic pressure (MAP) was observed with either pump. The IABP caused a significantly greater decrease than the CFP in 1) double product (13.138 +/- 2.476 mm Hg/min vs. 14.217 +/- 2.673 mm Hg/min, p = 0.023), 2) left ventricular systolic pressure (LVSP, 100 +/- 8 mm Hg vs. 106 +/- 10 mm Hg, p = 0.046), and 3) end-diastolic aortic pressure (EDAP, 70 +/- 6 mm Hg vs. 86 +/- 6 mm Hg, p = 0.000). The effects of both pumps on total tension time index and LAD flow were similar. After the induction of severe HF, the IABP had its main effects on afterload and decreased LVSP from 88 +/- 6 mm Hg to 78 +/- 9 mm Hg, (p = 0.008), and EDAP from 57 +/- 9 mm Hg to 49 +/- 14 mm Hg, (p = 0.044), whereas the CFP exerted its effects mainly on preload, lowering LV end-diastolic pressure from 19 +/- 5 mm Hg to 11 +/- 4 mm Hg, (p = 0.002). CO and MAP were similarly increased by both assist systems. The IABP (by lowering afterload) and CFP (by lowering preload) both offered significant mechanical support in acute HF. However, afterload reduction offered principally by the IABP seems preferable for the recovery of the acutely failing heart.
APPARATUS FOR ELECTRON BEAM HEATING CONTROL
Jones, W.H.; Reece, J.B.
1962-09-18
An improved electron beam welding or melting apparatus is designed which utilizes a high voltage rectifier operating below its temperature saturation region to decrease variations in electron beam current which normally result from the gas generated in such apparatus. (AEC)
Improving Aerospace Engineering Students' Achievements by an Open Aero Control Experiment Apparatus
ERIC Educational Resources Information Center
Zeng, QingHua; Zhang, WeiHua; Huang, ZheZhi; Dong, RongHua
2014-01-01
This paper describes the development of an aero control experiment apparatus (ACEA) for use in aerospace control practical courses. The ACEA incorporates a systematic multihierarchy learning and teaching method, and was designed to improve aerospace engineering students' understanding of unmanned aerial vehicle (UAV) control systems. It offers a…
Apparatus for controlling fluidized beds
Rehmat, A.G.; Patel, J.G.
1987-05-12
An apparatus and process are disclosed for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance. 2 figs.
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
Cardiovascular studies using the chimpanzee (Pan troglodytes)
NASA Technical Reports Server (NTRS)
Hinds, J. E.; Cothran, L. N.; Hawthorne, E. W.
1977-01-01
Despite the phylogenetic similarities between chimpanzees and man, there exists a paucity of reliable data on normal cardiovascular function and the physiological responses of the system to standard interventions. Totally implanted biotelemetry systems or hardwire analog techniques were used to examine the maximum number of cardiovascular variables which could be simultaneously monitored without significantly altering the system's performance. This was performed in order to acquire base-line data not previously obtained in this species, to determine cardiovascular response to specific forcing functions such as ventricular pacing, drug infusions, and lower body negative pressure. A cardiovascular function profile protocol was developed in order to adjust independently the three major factors which modify ventricular performance, namely, left ventricular performance, left ventricular preload, afterload, and contractility. Cardiac pacing at three levels above the ambient rate was used to adjust end diastolic volume (preload). Three concentrations of angiotensin were infused continuously to evaluate afterload in a stepwide fashion. A continuous infusion of dobutamine was administered to raise the manifest contractile state of the heart.
Method and apparatus for controlling gas evolution from chemical reactions
Skorpik, J.R.; Dodson, M.G.
1999-05-25
The present invention is directed toward monitoring a thermally driven gas evolving chemical reaction with an acoustic apparatus. Signals from the acoustic apparatus are used to control a heater to prevent a run-away condition. A digestion module in combination with a robotic arm further automate physical handling of sample material reaction vessels. The invention is especially useful for carrying out sample procedures defined in EPA Methods SW-846. 8 figs.
Ahn, J M; Lee, J H; Choi, S W; Kim, W E; Omn, K S; Park, S K; Kim, W G; Roh, J R; Min, B G
1998-03-01
The moving actuator type total artificial heart (TAH) developed in the Seoul National University has numerous design improvements based upon the digital signal processor (DSP). These improvements include the implantability of all electronics, an automatic control algorithm, and extension of the battery run-time in connection with an amorphous silicon solar system (SS). The implantable electronics consist of the motor drive, main processor, intelligent Li ion battery management (LIBM) based upon the DSP, telemetry system, and transcutaneous energy transmission (TET) system. Major changes in the implantable electronics include decreasing the temperature rise by over 21 degrees C on the motor drive, volume reduction (40 x 55 x 33 mm, 7 cell assembly) of the battery pack using a Li ion (3.6 V/cell, 900 mA.h), and improvement of the battery run-time (over 40 min) while providing the cardiac output (CO) of 5 L/min at 100 mm Hg afterload when the external battery for testing is connected with the SS (2.5 W, 192.192, 1 kg) for the external battery recharge or the partial TAH drive. The phase locked loop (PLL) based telemetry system was implemented to improve stability and the error correction DSP algorithm programmed to achieve high accuracy. A field focused light emitting diode (LED) was used to obtain low light scattering along the propagation path, similar to the optical property of the laser and miniature sized, mounted on the pancake type TET coils. The TET operating resonance frequency was self tuned in a range of 360 to 410 kHz to provide enough power even at high afterloads. An automatic cardiac output regulation algorithm was developed based on interventricular pressure analysis and carried out in several animal experiments successfully. All electronics have been evaluated in vitro and in vivo and prepared for implantation of the TAH. Substantial progress has been made in designing a completely implantable TAH at the preclinical stage.
Electrical energy consumption control apparatuses and electrical energy consumption control methods
Hammerstrom, Donald J.
2012-09-04
Electrical energy consumption control apparatuses and electrical energy consumption control methods are described. According to one aspect, an electrical energy consumption control apparatus includes processing circuitry configured to receive a signal which is indicative of current of electrical energy which is consumed by a plurality of loads at a site, to compare the signal which is indicative of current of electrical energy which is consumed by the plurality of loads at the site with a desired substantially sinusoidal waveform of current of electrical energy which is received at the site from an electrical power system, and to use the comparison to control an amount of the electrical energy which is consumed by at least one of the loads of the site.
Monitoring And Controlling Hydroponic Flow
NASA Technical Reports Server (NTRS)
Dreschel, Thomas W.
1992-01-01
Pressure-monitoring and -controlling apparatus maintains slight suction required on nutrient solution in apparatus described in "Tubular Membrane Plant-Growth Unit" (KSC-11375), while overcoming gravity effects on operation of system on Earth. Suction helps to hold solution in tubular membrane.
Tensiometer and method of determining soil moisture potential in below-grade earthen soil
Hubbell, J.M.; Mattson, E.D.; Sisson, J.B.
1998-06-02
A tensiometer to in-situ determine below-grade soil moisture, potential of earthen soil includes, (a) an apparatus adapted for insertion into earthen soil below grade, the apparatus having a below-grade portion, and, comprising; (b) a porous material provided in the below-grade portion, the porous material at least in part defining a below-grade first fluid chamber; (c) a first fluid conduit extending outwardly of the first fluid chamber; (d) a first controllable isolation valve provided within the first fluid conduit, the first controllable isolation valve defining a second fluid chamber in fluid communication with the first fluid chamber through the first fluid conduit and the isolation valve, the first controllable isolation valve being received within the below-grade portion; and (e) a pressure transducer in fluid communication with the first fluid chamber, the pressure transducer being received within the below-grade portion. An alternate embodiment includes an apparatus adapted for insertion into earthen soil below grade, the apparatus having a below-grade portion, and including: (1) a porous material provided in the below-grade portion, the porous material at least in part defining a below-grade first fluid chamber; and (2) a pressure sensing apparatus in fluid communication with the first fluid chamber, the pressure sensing apparatus being entirely received within the below-grade portion. A method is also disclosed using the above and other apparatus. 6 figs.
Tensiometer and method of determining soil moisture potential in below-grade earthen soil
Hubbell, Joel M.; Mattson, Earl D.; Sisson, James B.
1998-01-01
A tensiometer to in situ determine below-grade soil moisture, potential of earthen soil includes, a) an apparatus adapted for insertion into earthen soil below grade, the apparatus having a below-grade portion, and, comprising; b) a porous material provided in the below-grade portion, the porous material at least in part defining a below-grade first fluid chamber; c) a first fluid conduit extending outwardly of the first fluid chamber; d) a first controllable isolation valve provided within the first fluid conduit, the first controllable isolation valve defining a second fluid chamber in fluid communication with the first fluid chamber through the first fluid conduit and the isolation valve, the first controllable isolation valve being received within the below-grade portion; and e) a pressure transducer in fluid communication with the first fluid chamber, the pressure transducer being received within the below-grade portion. An alternate embodiment includes an apparatus adapted for insertion into earthen soil below grade, the apparatus having a below-grade portion, and including: i) a porous material provided in the below-grade portion, the porous material at least in part defining a below-grade first fluid chamber; and ii) a pressure sensing apparatus in fluid communication with the first fluid chamber, the pressure sensing apparatus being entirely received within the below-grade portion. A method is also disclosed using the above and other apparatus.
Automated High-Temperature Hall-Effect Apparatus
NASA Technical Reports Server (NTRS)
Parker, James B.; Zoltan, Leslie D.
1992-01-01
Automated apparatus takes Hall-effect measurements of specimens of thermoelectric materials at temperatures from ambient to 1,200 K using computer control to obtain better resolution of data and more data points about three times as fast as before. Four-probe electrical-resistance measurements taken in 12 electrical and 2 magnetic orientations to characterize specimens at each temperature. Computer acquires data, and controls apparatus via three feedback loops: one for temperature, one for magnetic field, and one for electrical-potential data.
Computer controlled multisensor thermocouple apparatus for invasive measurement of temperature.
Hanus, J; Záhora, J; Volenec, K
1996-01-01
The computer controlled apparatus for invasive measurement of temperature profile of biological systems based on original miniature multithermocouple probe is described in this article. The main properties of measuring system were verified by using the original testing device.
Method and apparatus for anti-islanding protection of distributed generations
Ye, Zhihong; John, Vinod; Wang, Changyong; Garces, Luis Jose; Zhou, Rui; Li, Lei; Walling, Reigh Allen; Premerlani, William James; Sanza, Peter Claudius; Liu, Yan; Dame, Mark Edward
2006-03-21
An apparatus for anti-islanding protection of a distributed generation with respect to a feeder connected to an electrical grid is disclosed. The apparatus includes a sensor adapted to generate a voltage signal representative of an output voltage and/or a current signal representative of an output current at the distributed generation, and a controller responsive to the signals from the sensor. The controller is productive of a control signal directed to the distributed generation to drive an operating characteristic of the distributed generation out of a nominal range in response to the electrical grid being disconnected from the feeder.
Method and apparatus for controlling LCL converters using asymmetric voltage cancellation techniques
Wu, Hunter; Sealy, Kylee Devro; Sharp, Bryan Thomas; Gilchrist, Aaron
2016-01-26
A method and apparatus for LCL resonant converter control utilizing Asymmetric Voltage Cancellation is described. The methods to determine the optimal trajectory of the control variables are discussed. Practical implementations of sensing load parameters are included. Simple PI, PID and fuzzy logic controllers are included with AVC for achieving good transient response characteristics with output current regulation.
Apparatus for testing for infection by a retrovirus
Layne, Scott P.; Beugelsdijk, Tony J.
1999-01-01
An apparatus for testing specimens for infection by a retrovirus is described. The apparatus comprises a process controller including a communications module for translating user commands into test instrument suite commands and a means for communicating specimen test results to a user. The apparatus further comprises a test instrument suite including a means for treating the specimen to manifest an observable result and a detector for measuring the observable result.
In-line manufacture of carbon nanotubes
Brambilla, Nicol Michele; Signorelli, Riccardo; Martini, Fabrizio; Corripio Luna, Oscar Enrique
2015-04-28
Mass production of carbon nanotubes (CNT) are facilitated by methods and apparatus disclosed herein. Advantageously, the methods and apparatus make use of a single production unit, and therefore provide for uninterrupted progress in a fabrication process. Embodiments of control systems for a variety of CNT production apparatus are included.
NASA Technical Reports Server (NTRS)
Laskowski, Edward L. (Inventor)
1995-01-01
An apparatus for sensing a target characteristic, such as relative distance between the apparatus and target, target thickness, target material, or lateral position between the apparatus and the target, includes a coil for directing an electro-magnetic field at the target. A voltage controlled oscillator energizes the coil at a resonant frequency which is functionally related to the target characteristic. The coil has an effective impedance value at resonance functionally related to the target characteristic. A frequency monitor measures the resonant frequency. An impedance monitor determines the impedance value when the drive frequency is at the resonant value. A PROM or controller determines the target characteristic in response to the measured resonant frequency and the determined impedance value. The PROM or controller provides a signal responsive to the determined target characteristic.
10 CFR 35.655 - Five-year inspection for teletherapy and gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Five-year inspection for teletherapy and gamma stereotactic radiosurgery units. 35.655 Section 35.655 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...
10 CFR 35.655 - Five-year inspection for teletherapy and gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Five-year inspection for teletherapy and gamma stereotactic radiosurgery units. 35.655 Section 35.655 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...
10 CFR 35.655 - Five-year inspection for teletherapy and gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Five-year inspection for teletherapy and gamma stereotactic radiosurgery units. 35.655 Section 35.655 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...
10 CFR 35.642 - Periodic spot-checks for teletherapy units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Periodic spot-checks for teletherapy units. 35.642 Section 35.642 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.642 Periodic spot-checks...
10 CFR 35.655 - Five-year inspection for teletherapy and gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Five-year inspection for teletherapy and gamma stereotactic radiosurgery units. 35.655 Section 35.655 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...
10 CFR 35.655 - Five-year inspection for teletherapy and gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Five-year inspection for teletherapy and gamma stereotactic radiosurgery units. 35.655 Section 35.655 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic...
10 CFR 35.642 - Periodic spot-checks for teletherapy units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Periodic spot-checks for teletherapy units. 35.642 Section 35.642 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.642 Periodic spot-checks...
10 CFR 35.642 - Periodic spot-checks for teletherapy units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Periodic spot-checks for teletherapy units. 35.642 Section 35.642 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.642 Periodic spot-checks...
10 CFR 35.642 - Periodic spot-checks for teletherapy units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Periodic spot-checks for teletherapy units. 35.642 Section 35.642 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.642 Periodic spot-checks...
Apparatus and method for constant flow oxidizing of organic materials
Surma, Jeffrey E.; Nelson, Norvell; Steward, G. Anthony; Bryan, Garry H.
1999-01-01
The invention is a method and apparatus using high cerium concentration in the anolyte of an electrochemical cell to oxidize organic materials. The method and apparatus further use an ultrasonic mixer to enhance the oxidation rate of the organic material in the electrochemical cell. A reaction vessel provides an advantage of independent reaction temperature control and electrochemical cell temperature control. A separate or independent reaction vessel may be used without an ultrasonic mixer to oxidize gaseous phase organic materials.
Method and apparatus for deregistering multi-filament tow and product thereof
Lukhard, Craig R.; Potter, Jerry F.; Todd, Maurice C.
1995-01-01
A method and apparatus for deregistering drawn crimped nylon multifilament tow includes the steps of stretching the tow under constant controlled tension at a temperature below the glass transition temperature of the nylon. The apparatus includes means for sensing the tension of the tow between the feed and draw sections of a stretching device and producing a signal representative of the tension sensed and a controller for changing the speed of the draw section actuated by said signal.
Apparatus for downward transport of heat
Neeper, D.A.; Hedstrom, J.C.
1985-08-05
An apparatus for the downward transport of heat by vaporization of a working fluid, usually from a collector which can be powered by the sun to a condenser which drains the condensed working fluid to a lower reservoir, is controled by a control valve which is operationally dependent upon the level of working fluid in either the lower reservoir or an upper reservoir which feeds the collector. Condensed working fluid is driven from the lower to the upper reservoir by vaporized working fluid whose flow is controled by the controll valve. The upper reservoir is in constant communication with the condenser which prevents a buildup in temperature/pressure as the apparatus goes through successive pumping cycles.
Apparatus and method for gelling liquefied gasses
NASA Technical Reports Server (NTRS)
Elliott, Adam (Inventor); DiSalvo, Roberto (Inventor); Shepherd, Phillip (Inventor); Kosier, Ryan (Inventor)
2011-01-01
A method and apparatus for gelling liquid propane and other liquefied gasses includes a temperature controlled churn mixer, vacuum pump, liquefied gas transfer tank, and means for measuring amount of material entering the mixer. The apparatus and method are particularly useful for the production of high quality rocket fuels and propellants.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
... Suction Apparatus Device Intended for Negative Pressure Wound Therapy AGENCY: Food and Drug Administration...- powered suction apparatus device intended for negative pressure wound therapy (NPWT) into class II... ``Class II Special Controls Guidance Document: Non-Powered Suction Apparatus Device Intended for Negative...
How-to-Do-It: Apparatus & Experimental Design for Measuring Fermentation Rates in Yeast.
ERIC Educational Resources Information Center
Tatina, Robert
1989-01-01
Describes an apparatus that facilitates the quantitative study of fermentation in yeast by allowing simultaneous measurements of fermentation rates in several treatments and a control. Explains a laboratory procedure in which the apparatus is used. Several suggestions for further investigations are included. (Author/RT)
Apparatus and process for active pulse intensity control of laser beam
Wilcox, Russell B.
1992-01-01
An optically controlled laser pulse energy control apparatus and process is disclosed wherein variations in the energy of a portion of the laser beam are used to vary the resistance of a photodetector such as a photoresistor through which a control voltage is fed to a light intensity controlling device through which a second portion of the laser beam passes. Light attenuation means are provided to vary the intensity of the laser light used to control the resistance of the photodetector. An optical delay path is provided through which the second portion of the beam travels before reaching the light intensity controlling device. The control voltage is supplied by a variable power supply. The apparatus may be tuned to properly attenuate the laser beam passing through the intensity controlling device by adjusting the power supply, the optical delay path, or the light attenuating means.
Borenstein, Johann; Granosik, Grzegorz
2005-03-22
An apparatus for traversing obstacles having an elongated, round, flexible body that includes a plurality of segments interconnected by an integrated joint actuator assembly. The integrated joint actuator assembly includes a plurality of bellows-type actuators individually coupling adjacent segments to permit pivotal actuation of the apparatus therebetween. A controller is employed to maintain proper positional control and stiffness control while minimize air flow.
1995-09-12
Two versions of (PCAM) Protein Crystallization Apparatus for Microgravity, (DCAM) Diffusion Controled Crystallization Apparatus is in the (STES) Single Locker Thermal Enclosure System. Principal Investigator was Dan Carter.
Crystal growth and annealing method and apparatus
Gianoulakis, Steven E.; Sparrow, Robert
2001-01-01
A method and apparatus for producing crystals that minimizes birefringence even at large crystal sizes, and is suitable for production of CaF.sub.2 crystals. The method of the present invention comprises annealing a crystal by maintaining a minimal temperature gradient in the crystal while slowly reducing the bulk temperature of the crystal. An apparatus according to the present invention includes a thermal control system added to a crystal growth and annealing apparatus, wherein the thermal control system allows a temperature gradient during crystal growth but minimizes the temperature gradient during crystal annealing. An embodiment of the present invention comprises a secondary heater incorporated into a conventional crystal growth and annealing apparatus. The secondary heater supplies heat to minimize the temperature gradients in the crystal during the annealing process. The secondary heater can mount near the bottom of the crucible to effectively maintain appropriate temperature gradients.
NASA Technical Reports Server (NTRS)
Fork, Richard Lynn (Inventor); Jones, Darryl Keith (Inventor); Keys, Andrew Scott (Inventor)
2000-01-01
By applying a photonic signal to a microresonator that includes a photonic bandgap delay apparatus having a photonic band edge transmission resonance at the frequency of the photonic signal, the microresonator imparts a predetermined delay to the photonic signal. The photonic bandgap delay apparatus also preferably has a photonic band edge transmission resonance bandwidth which is at least as wide as the bandwidth of the photonic signal such that a uniform delay is imparted over the entire bandwidth of the photonic signal. The microresonator also includes a microresonator cavity, typically defined by a pair of switchable mirrors, within which the photonic bandgap delay apparatus is disposed. By requiring the photonic signal to oscillate within the microresonator cavity so as to pass through the photonic bandgap delay apparatus several times, the microresonator can controllably impart an adjustable delay to the photonic signal.
Apparatus and method for tracking a molecule or particle in three dimensions
Werner, James H [Los Alamos, NM; Goodwin, Peter M [Los Alamos, NM; Lessard, Guillaume [Santa Fe, NM
2009-03-03
An apparatus and method were used to track the movement of fluorescent particles in three dimensions. Control software was used with the apparatus to implement a tracking algorithm for tracking the motion of the individual particles in glycerol/water mixtures. Monte Carlo simulations suggest that the tracking algorithms in combination with the apparatus may be used for tracking the motion of single fluorescent or fluorescently labeled biomolecules in three dimensions.
Automatic inoculating apparatus. [includes movable carraige, drive motor, and swabbing motor
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Mills, S. M. (Inventor)
1974-01-01
An automatic inoculating apparatus for agar trays is described and using a simple inoculating element, such as a cotton swab or inoculating loop. The apparatus includes a movable carriage for supporting the tray to be inoculated, a drive motor for moving the tray along a trackway, and a swabbing motor for automatically swabbing the tray during the movement. An actuator motor controls lowering of the inoculating element onto the tray and lifting of the inoculating element. An electrical control system, including limit microswitches, enables automatic control of the actuator motor and return of the carriage to the initial position after inoculating is completed.
Microelectromechanical reciprocating-tooth indexing apparatus
Allen, James J.
1999-01-01
An indexing apparatus is disclosed that can be used to rotate a gear or move a rack in a precise, controllable manner. The indexing apparatus, based on a reciprocating shuttle driven by one or more actuators, can be formed either as a micromachine, or as a millimachine. The reciprocating shuttle of the indexing apparatus can be driven by a thermal, electrostatic or electromagnetic actuator, with one or more wedge-shaped drive teeth of the shuttle being moveable to engage and slide against indexing teeth on the gear or rack, thereby moving the gear or rack. The indexing apparatus can be formed by either surface micromachining processes or LIGA processes, depending on the size of the apparatus that is to be formed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
...: Non-Powered Suction Apparatus Device Intended for Negative Pressure Wound Therapy; Availability AGENCY...-powered Suction Apparatus Device Intended for Negative Pressure Wound Therapy (NPWT).'' This guidance document describes a means by which non-powered suction apparatus devices intended for NPWT may comply with...
Wilson, David G [Tijeras, NM; Robinett, III, Rush D.
2012-02-21
A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.
Flash drive memory apparatus and method
NASA Technical Reports Server (NTRS)
Hinchey, Michael G. (Inventor)
2010-01-01
A memory apparatus includes a non-volatile computer memory, a USB mass storage controller connected to the non-volatile computer memory, the USB mass storage controller including a daisy chain component, a male USB interface connected to the USB mass storage controller, and at least one other interface for a memory device, other than a USB interface, the at least one other interface being connected to the USB mass storage controller.
Multiple-channel, total-reflection optic with controllable divergence
Gibson, David M.; Downing, Robert G.
1997-01-01
An apparatus and method for providing focused x-ray, gamma-ray, charged particle and neutral particle, including neutron, radiation beams with a controllable amount of divergence are disclosed. The apparatus features a novel use of a radiation blocking structure, which, when combined with multiple-channel total reflection optics, increases the versatility of the optics by providing user-controlled output-beam divergence.
Multiple-channel, total-reflection optic with controllable divergence
Gibson, D.M.; Downing, R.G.
1997-02-18
An apparatus and method for providing focused x-ray, gamma-ray, charged particle and neutral particle, including neutron, radiation beams with a controllable amount of divergence are disclosed. The apparatus features a novel use of a radiation blocking structure, which, when combined with multiple-channel total reflection optics, increases the versatility of the optics by providing user-controlled output-beam divergence. 11 figs.
Control of small phased-array antennas
NASA Technical Reports Server (NTRS)
Doland, G. D.
1978-01-01
Series of reports, patent descriptions, calculator programs, and other literature describes antenna control and steering apparatus for seven-element phased array. Though series contains information specific to particular system, it illustrates methods that can be applied to antennas with greater or fewer numbers of elements. Included are programs for calculating beam parameters and design functions and information to interfacing digital controller to beam-steering apparatus.
Crystal growth and annealing for minimized residual stress
Gianoulakis, Steven E.
2002-01-01
A method and apparatus for producing crystals that minimizes birefringence even at large crystal sizes, and is suitable for production of CaF.sub.2 crystals. The method of the present invention comprises annealing a crystal by maintaining a minimal temperature gradient in the crystal while slowly reducing the bulk temperature of the crystal. An apparatus according to the present invention includes a thermal control system added to a crystal growth and annealing apparatus, wherein the thermal control system allows a temperature gradient during crystal growth but minimizes the temperature gradient during crystal annealing.
Apparatus for controlling nuclear core debris
Jones, Robert D.
1978-01-01
Nuclear reactor apparatus for containing, cooling, and dispersing reactor debris assumed to flow from the core area in the unlikely event of an accident causing core meltdown. The apparatus includes a plurality of horizontally disposed vertically spaced plates, having depressions to contain debris in controlled amounts, and a plurality of holes therein which provide natural circulation cooling and a path for debris to continue flowing downward to the plate beneath. The uppermost plates may also include generally vertical sections which form annular-like flow areas which assist the natural circulation cooling.
29 CFR 1926.152 - Flammable and combustible liquids.
Code of Federal Regulations, 2010 CFR
2010-07-01
... access way to permit approach of fire control apparatus. (3) The storage area shall be graded in a manner... to permit approach of fire control apparatus. (5) Storage areas shall be kept free of weeds, debris... wooden storage cabinets shall be constructed in the following manner, or equivalent: The bottom, sides...
29 CFR 1926.152 - Flammable and combustible liquids.
Code of Federal Regulations, 2011 CFR
2011-07-01
... access way to permit approach of fire control apparatus. (3) The storage area shall be graded in a manner... to permit approach of fire control apparatus. (5) Storage areas shall be kept free of weeds, debris... wooden storage cabinets shall be constructed in the following manner, or equivalent: The bottom, sides...
Mechanisms of right heart disease in pulmonary hypertension (2017 Grover Conference Series).
Asosingh, Kewal; Erzurum, Serpil
2018-01-01
Current dogma is that pathological hypertrophy of the right ventricle is a direct consequence of pulmonary vascular remodeling. However, progression of right ventricle dysfunction is not always lung-dependent. Increased afterload caused by pulmonary vascular remodeling initiates the right ventricle hypertrophy, but determinants leading to adaptive or maladaptive hypertrophy and failure remain unknown. Ischemia in a hypertrophic right ventricle may directly contribute to right heart failure. Rapidly enlarging cardiomyocytes switch from aerobic to anaerobic energy generation resulting in cell growth under relatively hypoxic conditions. Cardiac muscle reacts to an increased afterload by over-activation of the sympathetic system and uncoupling and downregulation of β-adrenergic receptors. Recent studies suggest that β blocker therapy in PH is safe, well tolerated, and preserves right ventricle function and cardiac output by reducing right ventricular glycolysis. Fibrosis, an evolutionary conserved process in host defense and wound healing, is dysregulated in maladaptive cardiac tissue contributing directly to right ventricle failure. Despite several mechanisms having been suggested in right heart disease, the causes of maladaptive cardiac remodeling remain unknown and require further research.
Design of a pulsatile DC electromagnetic blood pump for ECMO.
Liu, Jingjing; Ge, Bin; Lu, Tong
2017-08-09
Extracorporeal membrane oxygenation (ECMO) has developed rapidly and becomes a significant treatment for emergency. Current blood pumps for ECMO have different disadvantages. To design a pulsatile DC electromagnetic blood pump for ECMO. The design is presented with a driving principle which the rectilinear reciprocation of a magnet inside energized solenoids is implemented, and with a structure of solenoids with compensation coils. Furthermore, a prototype was constructed and the performance indexes of it were measured with the experimental evaluations, where the acceleration experiment was performed without any loads, and the flows were measured in the ranges of preload and afterload are 5 to 30 mmHg and 50 to 80 mmHg respectively when the frequency of the motion is 80 beats per minute. The electromagnetic force is greater than 1.4 N when the DC reaches 2.7 A and the flow of the prototype is greater than 3.0 L/min except the differences between the preload and the afterload are greater than or equal to 70 mmHg. The design of the blood pump for ECMO meets the theoretical and clinical requirements.
Calibration Test Set for a Phase-Comparison Digital Tracker
NASA Technical Reports Server (NTRS)
Boas, Amy; Li, Samuel; McMaster, Robert
2007-01-01
An apparatus that generates four signals at a frequency of 7.1 GHz having precisely controlled relative phases and equal amplitudes has been designed and built. This apparatus is intended mainly for use in computer-controlled automated calibration and testing of a phase-comparison digital tracker (PCDT) that measures the relative phases of replicas of the same X-band signal received by four antenna elements in an array. (The relative direction of incidence of the signal on the array is then computed from the relative phases.) The present apparatus can also be used to generate precisely phased signals for steering a beam transmitted from a phased antenna array. The apparatus (see figure) includes a 7.1-GHz signal generator, the output of which is fed to a four-way splitter. Each of the four splitter outputs is attenuated by 10 dB and fed as input to a vector modulator, wherein DC bias voltages are used to control the in-phase (I) and quadrature (Q) signal components. The bias voltages are generated by digital-to-analog- converter circuits on a control board that receives its digital control input from a computer running a LabVIEW program. The outputs of the vector modulators are further attenuated by 10 dB, then presented at high-grade radio-frequency connectors. The attenuation reduces the effects of changing mismatch and reflections. The apparatus was calibrated in a process in which the bias voltages were first stepped through all possible IQ settings. Then in a reverse interpolation performed by use of MATLAB software, a lookup table containing 3,600 IQ settings, representing equal amplitude and phase increments of 0.1 , was created for each vector modulator. During operation of the apparatus, these lookup tables are used in calibrating the PCDT.
Apparatus and method for gelling liquefied gasses
NASA Technical Reports Server (NTRS)
Elliott, Adam (Inventor); DiSalvo, Roberto (Inventor); Shepherd, Phillip (Inventor); Kosier, Ryan (Inventor)
2010-01-01
The present invention is a method and apparatus for gelling liquid propane and other liquefied gasses. The apparatus includes a temperature controlled churn mixer, vacuum pump, liquefied gas transfer tank, and means for measuring amount of material entering the mixer. The method uses gelling agents such as silicon dioxide, clay, carbon, or organic or inorganic polymers, as well as dopants such as titanium, aluminum, and boron powders. The apparatus and method are particularly useful for the production of high quality rocket fuels and propellants.
Jackson, Darryl D.; Hollen, Robert M.
1983-01-01
A new automatable cleaning apparatus which makes use of a method of very thoroughly and quickly cleaning a gauze electrode used in chemical analyses is given. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg. plutonium sample was removed in less than 3 minutes, using only about 60 ml. of rinse solution and two main rinse steps.
Phase change thermal control materials, method and apparatus
NASA Technical Reports Server (NTRS)
Buckley, Theresa M. (Inventor)
2001-01-01
An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.
Apparatus for automated testing of biological specimens
Layne, Scott P.; Beugelsdijk, Tony J.
1999-01-01
An apparatus for performing automated testing of infections biological specimens is disclosed. The apparatus comprise a process controller for translating user commands into test instrument suite commands, and a test instrument suite comprising a means to treat the specimen to manifest an observable result, and a detector for measuring the observable result to generate specimen test results.
Advanced particulate matter control apparatus and methods
Miller, Stanley J [Grand Forks, ND; Zhuang, Ye [Grand Forks, ND; Almlie, Jay C [East Grand Forks, MN
2012-01-10
Apparatus and methods for collection and removal of particulate matter, including fine particulate matter, from a gas stream, comprising a unique combination of high collection efficiency and ultralow pressure drop across the filter. The apparatus and method utilize simultaneous electrostatic precipitation and membrane filtration of a particular pore size, wherein electrostatic collection and filtration occur on the same surface.
Right Ventricular Perfusion: Physiology and Clinical Implications.
Crystal, George J; Pagel, Paul S
2018-01-01
Regulation of blood flow to the right ventricle differs significantly from that to the left ventricle. The right ventricle develops a lower systolic pressure than the left ventricle, resulting in reduced extravascular compressive forces and myocardial oxygen demand. Right ventricular perfusion has eight major characteristics that distinguish it from left ventricular perfusion: (1) appreciable perfusion throughout the entire cardiac cycle; (2) reduced myocardial oxygen uptake, blood flow, and oxygen extraction; (3) an oxygen extraction reserve that can be recruited to at least partially offset a reduction in coronary blood flow; (4) less effective pressure-flow autoregulation; (5) the ability to downregulate its metabolic demand during coronary hypoperfusion and thereby maintain contractile function and energy stores; (6) a transmurally uniform reduction in myocardial perfusion in the presence of a hemodynamically significant epicardial coronary stenosis; (7) extensive collateral connections from the left coronary circulation; and (8) possible retrograde perfusion from the right ventricular cavity through the Thebesian veins. These differences promote the maintenance of right ventricular oxygen supply-demand balance and provide relative resistance to ischemia-induced contractile dysfunction and infarction, but they may be compromised during acute or chronic increases in right ventricle afterload resulting from pulmonary arterial hypertension. Contractile function of the thin-walled right ventricle is exquisitely sensitive to afterload. Acute increases in pulmonary arterial pressure reduce right ventricular stroke volume and, if sufficiently large and prolonged, result in right ventricular failure. Right ventricular ischemia plays a prominent role in these effects. The risk of right ventricular ischemia is also heightened during chronic elevations in right ventricular afterload because microvascular growth fails to match myocyte hypertrophy and because microvascular dysfunction is present. The right coronary circulation is more sensitive than the left to α-adrenergic-mediated constriction, which may contribute to its greater propensity for coronary vasospasm. This characteristic of the right coronary circulation may increase its vulnerability to coronary vasoconstriction and impaired right ventricular perfusion during administration of α-adrenergic receptor agonists.
Patient-specific computational modeling of blood flow in the pulmonary arterial circulation.
Kheyfets, Vitaly O; Rios, Lourdes; Smith, Triston; Schroeder, Theodore; Mueller, Jeffrey; Murali, Srinivas; Lasorda, David; Zikos, Anthony; Spotti, Jennifer; Reilly, John J; Finol, Ender A
2015-07-01
Computational fluid dynamics (CFD) modeling of the pulmonary vasculature has the potential to reveal continuum metrics associated with the hemodynamic stress acting on the vascular endothelium. It is widely accepted that the endothelium responds to flow-induced stress by releasing vasoactive substances that can dilate and constrict blood vessels locally. The objectives of this study are to examine the extent of patient specificity required to obtain a significant association of CFD output metrics and clinical measures in models of the pulmonary arterial circulation, and to evaluate the potential correlation of wall shear stress (WSS) with established metrics indicative of right ventricular (RV) afterload in pulmonary hypertension (PH). Right Heart Catheterization (RHC) hemodynamic data and contrast-enhanced computed tomography (CT) imaging were retrospectively acquired for 10 PH patients and processed to simulate blood flow in the pulmonary arteries. While conducting CFD modeling of the reconstructed patient-specific vasculatures, we experimented with three different outflow boundary conditions to investigate the potential for using computationally derived spatially averaged wall shear stress (SAWSS) as a metric of RV afterload. SAWSS was correlated with both pulmonary vascular resistance (PVR) (R(2)=0.77, P<0.05) and arterial compliance (C) (R(2)=0.63, P<0.05), but the extent of the correlation was affected by the degree of patient specificity incorporated in the fluid flow boundary conditions. We found that decreasing the distal PVR alters the flow distribution and changes the local velocity profile in the distal vessels, thereby increasing the local WSS. Nevertheless, implementing generic outflow boundary conditions still resulted in statistically significant SAWSS correlations with respect to both metrics of RV afterload, suggesting that the CFD model could be executed without the need for complex outflow boundary conditions that require invasively obtained patient-specific data. A preliminary study investigating the relationship between outlet diameter and flow distribution in the pulmonary tree offers a potential computationally inexpensive alternative to pressure based outflow boundary conditions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Motorized control for mirror mount apparatus
Cutburth, Ronald W.
1989-01-01
A motorized control and automatic braking system for adjusting mirror mount apparatus is disclosed. The motor control includes a planetary gear arrangement to provide improved pitch adjustment capability while permitting a small packaged design. The motor control for mirror mount adjustment is suitable for laser beam propagation applications. The brake is a system of constant contact, floating detents which engage the planetary gear at selected between-teeth increments to stop rotation instantaneously when the drive motor stops.
Hybrid Contactless Heating and Levitation
NASA Technical Reports Server (NTRS)
Lee, M. C.
1985-01-01
Acoustic and electromagnetic fields applied. In contactless processing apparatus, acoustic and electromagnetic levitating fields employed alternately or simultaneously with amplitude of each controlled to produce various combinations of heating, cooling, and levitation. Apparatus provides rapid heating and cooling or slow heating and cooling for such processes as nucleation, crystallization, incubation, deep undercooling, and heterogeneity control.
Apparatus for Precise Indium-Bump Bonding of Microchips
NASA Technical Reports Server (NTRS)
Wild, Larry; Mulder, Jerry; Alvarado, Nicholas
2005-01-01
An improved apparatus has been designed and built for use in precise positioning and pressing of a microchip onto a substrate (which could, optionally, be another microchip) for the purpose of indium-bump bonding. The apparatus (see figure) includes the following: A stereomicroscope, A stage for precise positioning of the microchip in rotation angle (theta) about the nominally vertical pressing axis and in translation along two nominally horizontal coordinate axes (x and y), and An actuator system that causes a bonding tip to press the microchip against the substrate with a precisely controlled force. In operation, the microscope and the stage are used to position the microchip under the bonding tip and to align the indium bumps on the chip and the substrate, then the actuator system is used to apply a prescribed bonding force for a prescribed time. The improved apparatus supplants a partly similar prior apparatus that operated with less precision and repeatability, producing inconsistent and unreliable bonds. Results of the use of the prior apparatus included broken microchips, uneven bonds, and bonds characterized, variously, by overcompression or undercompression. In that apparatus, the bonding force was generated and controlled by use of a micrometer head positioned over the center of a spring-loaded scale, and the force was applied to the microchip via the scale, which was equipped for digital readout of the force. The inconsistency of results was attributed to the following causes: It was not possible to control the bonding force with sufficient precision or repeatability. Particularly troublesome was the inability to control the force at levels less than the weight of 150 g. Excessive compliance in the spring-loaded scale, combined with deviations from parallelarity of the substrate and bonding-tip surfaces, gave rise to nonuniformity in the pressure applied to the microchip, thereby generating excessive stresses and deformations in the microchip. In the improved apparatus, the bonding tip and the components that hold the substrate and the microchip are more rigid and precise than in the prior apparatus, so as to ensure less deviation from parallelarity of the bonding-tip and substrate surfaces, thereby ensuring more nearly uniform distribution of bonding force over the area of the microchip. The bonding force is now applied through, and measured by, a load cell that makes it possible to exert finer control over the force. The force can be set at any value between 0 and the weight of 800 g in increments of 0.2 g.
A new ball launching system with controlled flight parameters for catching experiments.
d'Avella, A; Cesqui, B; Portone, A; Lacquaniti, F
2011-03-30
Systematic investigations of sensorimotor control of interceptive actions in naturalistic conditions, such as catching or hitting a ball moving in three-dimensional space, requires precise control of the projectile flight parameters and of the associated visual stimuli. Such control is challenging when air drag cannot be neglected because the mapping of launch parameters into flight parameters cannot be computed analytically. We designed, calibrated, and experimentally validated an actuated launching apparatus that can control the average spatial position and flight duration of a ball at a given distance from a fixed launch location. The apparatus was constructed by mounting a ball launching machine with adjustable delivery speed on an actuated structure capable of changing the spatial orientation of the launch axis while projecting balls through a hole in a screen hiding the apparatus. The calibration procedure relied on tracking the balls with a motion capture system and on approximating the mapping of launch parameters into flight parameters by means of polynomials functions. Polynomials were also used to estimate the variability of the flight parameters. The coefficients of these polynomials were obtained using the launch and flight parameters of 660 launches with 65 different initial conditions. The relative accuracy and precision of the apparatus were larger than 98% for flight times and larger than 96% for ball heights at a distance of 6m from the screen. Such novel apparatus, by reliably and automatically controlling desired ball flight characteristics without neglecting air drag, allows for a systematic investigation of naturalistic interceptive tasks. Copyright © 2011 Elsevier B.V. All rights reserved.
Grinding assembly, grinding apparatus, weld joint defect repair system, and methods
Larsen, Eric D.; Watkins, Arthur D.; Bitsoi, Rodney J.; Pace, David P.
2005-09-27
A grinding assembly for grinding a weld joint of a workpiece includes a grinder apparatus, a grinder apparatus includes a grinding wheel configured to grind the weld joint, a member configured to receive the grinding wheel, the member being configured to be removably attached to the grinder apparatus, and a sensor assembly configured to detect a contact between the grinding wheel and the workpiece. The grinding assembly also includes a processing circuitry in communication with the grinder apparatus and configured to control operations of the grinder apparatus, the processing circuitry configured to receive weld defect information of the weld joint from an inspection assembly to create a contour grinding profile to grind the weld joint in a predetermined shape based on the received weld defect information, and a manipulator having an end configured to carry the grinder apparatus, the manipulator further configured to operate in multiple dimensions.
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, A.N.; Soden, J.M.
1998-12-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits are disclosed. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal. 4 figs.
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, Ann N.; Soden, Jerry M.
1998-01-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal.
Method and automated apparatus for detecting coliform organisms
NASA Technical Reports Server (NTRS)
Dill, W. P.; Taylor, R. E.; Jeffers, E. L. (Inventor)
1980-01-01
Method and automated apparatus are disclosed for determining the time of detection of metabolically produced hydrogen by coliform bacteria cultured in an electroanalytical cell from the time the cell is inoculated with the bacteria. The detection time data provides bacteria concentration values. The apparatus is sequenced and controlled by a digital computer to discharge a spent sample, clean and sterilize the culture cell, provide a bacteria nutrient into the cell, control the temperature of the nutrient, inoculate the nutrient with a bacteria sample, measures the electrical potential difference produced by the cell, and measures the time of detection from inoculation.
Development of an Apparatus for Wind Tunnel Dynamic Experiments at High-alpha
NASA Technical Reports Server (NTRS)
Pedreiro, Nelson
1997-01-01
A unique experimental apparatus that allows a wind tunnel model two degrees of freedom has been designed and built. The apparatus was developed to investigate the use of new methods to augment aircraft control in the high angle of attack regime. The model support system provides a platform in which the roll-yaw coupling at high angles of attack can be studied in a controlled environment. Active cancellation of external effects is used to provide a system in which the dynamics are dominated by the aerodynamic loads acting on the wind tunnel model.
Controllers for Flow-Field Survey Apparatus
NASA Technical Reports Server (NTRS)
Ashby George C., JR.; Vaccarelli, M. D.
1986-01-01
Control systems of flow-field survey apparatuses of 22-inch (56centimeter) Hypersonic Helium Facility (two-dimensional) and 20-inch (51centimeter) Mach 6 Tunnel (three-dimensional) at Langley Research Center equipped with single-chip microcomputer and single-board microcomputer, respectively, to drive probes at selected speeds and perform other functions automatically. Various modes of operation programed as need arises. Both of these control systems fabricated relatively inexpensively from commercially available stock components.
Comparison of different cardiac relaxation indices.
Alipov, N N; Izrail'tyan, I M; Sokolov, A V; Trubetskaya, L V; Kuznetsova, T E
2001-05-01
Sensitivity (response to epinephrine infusion) and specificity (response to changes in pre- and afterload) of some cardiac relaxation indices were compared in acute experiments on cats treated with ganglionic blocker arfonad. Some new indices proposed by us provide better characteristics than widely used relaxation time constant (t) and maximum first derivative of the left ventricular pressure (-dP/dt)max.
Jackson, D.D.; Hollen, R.M.
1981-02-27
A method of very thoroughly and quikcly cleaning a guaze electrode used in chemical analyses is given, as well as an automobile cleaning apparatus which makes use of the method. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg plutonium sample was removed in less than 3 minutes, using only about 60 ml of rinse solution and two main rinse steps.
The Development of the Vestibular Apparatus Under Conditions of Weightlessness
NASA Technical Reports Server (NTRS)
Vinnikov, Y. A.; Gazenko, O. G.; Lychakov, D. V.; Palmbakh, L. R.
1984-01-01
A series of experiments has been carried out on the effect of space flight conditions on morphogenesis and the structure of the vestibular apparatus in amphibian and fish larvae. Larval development proceeded in weightlessness without serious morphological defects. The vestibular apparatus developed; its organization in the experimental animals did not differ qualitatively from that in the controls. The specific external stimulus (gravitation) appears not to be a necessary condition for the development of a gravitation receptor in ontogenesis although the appearance of the vestibular apparatus in phylogenesis was apparently related to this stimulus.
Tissue culture apparatus for flight experimentation
NASA Technical Reports Server (NTRS)
Scheld, H. W.; Magnuson, J. W.; Krikorian, A. D.
1985-01-01
The development of an apparatus for in-flight treatment of cells, tissues, or small organisms for microscopic and chemical analyses is discussed. The hardware for the apparatus is to have: (1) automated functions, (2) the capability to interface with ground-based facilities, (3) independently controlled chambers, (4) variable chamber configurations and volumes, and (4) the capabilities for processing the materials. The components of the equipment used on Skylab 3 for the study of animal cells are described. The design of an apparatus which incorporates all the required capabilities is proposed.
Chang, Tzyy-Shuh; Huang, Hsun-Hau; Lin, Chang-Hung
2007-10-02
An adjustable guide, includes two or more mechanisms each having a rotatable retaining element containing a retaining groove with a variable radius in its perimeter surface. The grooves form a guidance path to control the lateral, i.e. non-axial, motion of a long bar moving along a longitudinal axis during a production process.The diameter of the guidance path varies according to the variable radii of the grooves. The guidance path increases in size at a predetermined rate, from a point of origin to an end point on the retaining groove. Rotating the retaining elements causes the diameter of the retaining grooves to change so that the size of the guidance path can be changed to match the diameter of the bar being rolled, size of the guidance path can be changed to fit the diameter of a new bar rolled without having to exchange the guide for a different sized guide, reduce fiction between the bar and the guide, a media, such as compressed air, can be injected between the retaining elements via orifices.Each retaining element is attached to a mounting apparatus. The mounting apparatus can be fixed or flexible. The flexible mounting apparatus includes one or more springs and one or more shock absorbers. A force neutral position of the flexible mounting apparatus is designed to be located on the predetermined ideal bar path line. The flexible mounting apparatus dissipates kinetic energy from the bar thereby reducing the bar's lateral motion relative to the ideal bar path line.The damping ratio of the mounting apparatus can be adjustable to alter the product's vibration mode to enable better control of the bar's lateral motion.
Spectroscopic analysis and control
Tate; , James D.; Reed, Christopher J.; Domke, Christopher H.; Le, Linh; Seasholtz, Mary Beth; Weber, Andy; Lipp, Charles
2017-04-18
Apparatus for spectroscopic analysis which includes a tunable diode laser spectrometer having a digital output signal and a digital computer for receiving the digital output signal from the spectrometer, the digital computer programmed to process the digital output signal using a multivariate regression algorithm. In addition, a spectroscopic method of analysis using such apparatus. Finally, a method for controlling an ethylene cracker hydrogenator.
Development of a powered outdoor sealant fatigue test apparatus
Steven Lacher; R. Sam Williams; Corey Halpin; Christopher White
2005-01-01
This chapter describes a new cyclic fatigue test apparatus (CFTA) developed at the USDA Forest Service, Forest Products Laboratory. The new CFTA is computer controlled and powered by electric linear actuators. Computer control allows the CFTA to subject specimens to specific strain/time profiles or replicate input strain data in real time from thermal and/or moisture...
Vestibular Stimulation for ADHD: Randomized Controlled Trial of Comprehensive Motion Apparatus
ERIC Educational Resources Information Center
Clark, David L.; Arnold, L. Eugene; Crowl, Lindsay; Bozzolo, Hernan; Peruggia, Mario; Ramadan, Yaser; Bornstein, Robert; Hollway, Jill A.; Thompson, Susan; Malone, Krista; Hall, Kristy L.; Shelton, Sara B.; Bozzolo, Dawn R.; Cook, Amy
2008-01-01
Objective: This research evaluates effects of vestibular stimulation by Comprehensive Motion Apparatus (CMA) in ADHD. Method: Children ages 6 to 12 (48 boys, 5 girls) with ADHD were randomized to thrice-weekly 30-min treatments for 12 weeks with CMA, stimulating otoliths and semicircular canals, or a single-blind control of equal duration and…
Apparatus for stopping a vehicle
Wattenburg, Willard H [Walnut Creek, CA; McCallen, David B [Livermore, CA
2007-03-20
An apparatus for externally controlling one or more brakes on a vehicle having a pressurized fluid braking system. The apparatus can include a pressurizable vessel that is adapted for fluid-tight coupling to the braking system. Impact to the rear of the vehicle by a pursuit vehicle, shooting a target mounted on the vehicle or sending a signal from a remote control can all result in the fluid pressures in the braking system of the vehicle being modified so that the vehicle is stopped and rendered temporarily inoperable. A control device can also be provided in the driver's compartment of the vehicle for similarly rendering the vehicle inoperable. A driver or hijacker of the vehicle preferably cannot overcome the stopping action from the driver's compartment.
Illumination control apparatus for compensating solar light
NASA Technical Reports Server (NTRS)
Owens, L. J. (Inventor)
1978-01-01
An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.
Nuclear reactor control apparatus
Sridhar, Bettadapur N.
1983-11-01
Nuclear reactor core safety rod release apparatus comprises a control rod having a detent notch in the form of an annular peripheral recess at its upper end, a control rod support tube for raising and lowering the control rod under normal conditions, latches pivotally mounted on the control support tube with free ends thereof normally disposed in the recess in the control rod, and cam means for pivoting the latches out of the recess in the control rod when a scram condition occurs. One embodiment of the invention comprises an additional magnetically-operated latch for releasing the control rod under two different conditions, one involving seismic shock.
Microelectromechanical apparatus for elevating and tilting a platform
Miller, Samuel Lee; McWhorter, Paul Jackson; Rodgers, Murray Steven; Sniegowski, Jeffry J.; Barnes, Stephen M.
2003-04-08
A microelectromechanical (MEM) apparatus is disclosed which has a platform that can be elevated above a substrate and tilted at an arbitrary angle using a plurality of flexible members which support the platform and control its movement. Each flexible member is further controlled by one or more MEM actuators which act to bend the flexible member. The MEM actuators can be electrostatic comb actuators or vertical zip actuators, or a combination thereof. The MEM apparatus can include a mirror coating to form a programmable mirror for redirecting or switching one or more light beams for use in a projection display. The MEM apparatus with the mirror coating also has applications for switching light beams between optical fibers for use in a local area fiber optic network, or for use in fiber optic telecommunications or data communications systems.
Microelectromechanical apparatus for elevating and tilting a platform
Miller, Samuel Lee; McWhorter, Paul Jackson; Rodgers, Murray Steven; Sniegowski, Jeffry J.; Barnes, Stephen M.
2004-07-06
A microelectromechanical (MEM) apparatus is disclosed which has a platform that can be elevated above a substrate and tilted at an arbitrary angle using a plurality of flexible members which support the platform and control its movement. Each flexible member is further controlled by one or more MEM actuators which act to bend the flexible member. The MEM actuators can be electrostatic comb actuators or vertical zip actuators, or a combination thereof. The MEM apparatus can include a mirror coating to form a programmable mirror for redirecting or switching one or more light beams for use in a projection display. The MEM apparatus with-the mirror coating also has applications for switching light beams between optical fibers for use in a local area fiber optic network, or for use in fiber optic telecommunications or data communications systems.
Walsh, David O; Turner, Peter
2014-05-27
Technologies including NMR logging apparatus and methods are disclosed. Example NMR logging apparatus may include surface instrumentation and one or more downhole probes configured to fit within an earth borehole. The surface instrumentation may comprise a power amplifier, which may be coupled to the downhole probes via one or more transmission lines, and a controller configured to cause the power amplifier to generate a NMR activating pulse or sequence of pulses. Impedance matching means may be configured to match an output impedance of the power amplifier through a transmission line to a load impedance of a downhole probe. Methods may include deploying the various elements of disclosed NMR logging apparatus and using the apparatus to perform NMR measurements.
Nemanic, Sarah; Mills, Serena; Viehdorfer, Matt; Clark, Terri; Bailey, Mike
Teaching the anatomy of the canine larynx and hyoid apparatus is challenging because dissection disassembles and/or damages these structures, making it difficult to understand their three-dimensional (3D) anatomy and spatial interrelationships. This study assessed the effectiveness of an interactive, computerized 3D tutorial for teaching the anatomy of the canine larynx and hyoid apparatus using a randomized control design with students enrolled in the first-year professional program at Oregon State University College of Veterinary Medicine. All first-year students from 2 consecutive years were eligible. All students received the traditional methods of didactic teaching and dissection to learn the anatomy of the canine larynx and hyoid apparatus, after which they were divided into two statistically equal groups based on their cumulative anatomy test scores from the prior term. The tutorial group received an interactive, computerized tutorial developed by the investigators containing 3D images of the canine larynx and hyoid apparatus, while the control group received the same 3D images without the computerized tutorial. Both groups received the same post-learning assessment and survey. Sixty-three first-year students participated in the study, 28 in the tutorial group, and 35 in the control group. Post-learning assessment and survey scores were both significantly higher among students in the computerized tutorial group than those in the control group. This study demonstrates that a 3D computerized tutorial is more effective in teaching the anatomy of the canine hyoid apparatus and larynx than 3D images without a tutorial. Students likewise rated their learning experience higher when using the 3D computerized tutorial.
Hendrix, J.L.
1995-04-11
A laser initiated ordnance controller apparatus which provides a safe and arm scheme with no moving parts. The safe & arm apparatus provides isolation of firing energy to explosive devices using a combination of polarization isolation and control through acousto-optical deviation of laser energy pulses. The apparatus provides constant monitoring of the systems status and performs 100% built-in-test at any time prior to ordnance ignition without the risk of premature ignition or detonation. The apparatus has a computer controller, a solid state laser, an acousto-optic deflector and RF drive circuitry, built-in-test optics and electronics, and system monitoring capabilities. The optical system is completed from the laser beam power source to the pyrotechnic ordnance through fiber optic cabling, optical splitters and optical connectors. During operation of the apparatus, a command is provided by the computer controller and, simultaneous with laser flashlamp fire, the safe & arm device is opened for approximately 200 microseconds which allows the laser pulse to transmit through the device. The arm signal also energizes the laser power supply and activates the acousto-optical deflector. When the correct fire format command is received, the acousto-optic deflector moves to the selected event channel, and the channel is verified to ensure the system is pointing to the correct position. Laser energy is transmitted through the fiber where an ignitor or detonator designed to be sensitive to optical pulses is fired at the end of the fiber channel. Simultaneous event channels may also be utilized by optically splitting a single event channel. The built-in-test may be performed anytime prior to ordnance ignition. 6 figures.
Hendrix, James L.
1995-01-01
A laser initiated ordnance controller apparatus which provides a safe and m scheme with no moving parts. The safe & arm apparatus provides isolation of firing energy to explosive devices using a combination of polarization isolation and control through acousto-optical deviation of laser energy pulses. The apparatus provides constant monitoring of the systems status and performs 100% built-in-test at any time prior to ordnance ignition without the risk of premature ignition or detonation. The apparatus has a computer controller, a solid state laser, an acousto-optic deflector and RF drive circuitry, built-in-test optics and electronics, and system monitoring capabilities. The optical system is completed from the laser beam power source to the pyrotechnic ordnance through fiber optic cabling, optical splitters and optical connectors. During operation of the apparatus, a command is provided by the computer controller and, simultaneous with laser flashlamp fire, the safe & arm device is opened for approximately 200 microseconds which allows the laser pulse to transmit through the device. The arm signal also energizes the laser power supply and activates the acousto-optical deflector. When the correct fire format command is received, the acousto-optic deflector moves to the selected event channel, and the channel is verified to ensure the system is pointing to the correct position. Laser energy is transmitted through the fiber where an ignitor or detonator designed to be sensitive to optical pulses is fired at the end of the fiber channel. Simultaneous event channels may also be utilized by optically splitting a single event channel. The built-in-test may be performed anytime prior to ordnance ignition.
Leidinger, F; Jörgens, V; Chantelau, E; Berchtold, P; Berger, M
1980-07-26
Home blood glucose monitoring by diabetic patients has recently been advocated as an effective means to improve metabolic control. The Glucocheck apparatus, a pocket-size battery-driven reflectance-meter (in Germany commercially available under the name Glucose-meter), has been evaluated for accuracy and practicability. In 450 blood glucose measurements, the variance between the values obtained using the Glucocheck apparatus and routine clinical laboratory procedures was +/- 11.7%. Especially in the low range of blood glucose concentrations, the Glucocheck method was very reliable. The quantitative precision of the Glucocheck method depends, however, quite considerably on the ability of the patient to use the apparatus correctly. In order to profit from Glucocheck in clinical practice, particular efforts to educate the patients in its use are necessary.
Apparatus for performing high-temperature fiber push-out testing
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey I. (Inventor); Ebihara, Ben T. (Inventor)
1994-01-01
The apparatus disclosed in the present invention measures the force at which a fiber resist the motion of an indenter driven at constant speed. This apparatus conducts these test in a vacuum of about 10(exp -6) tort and at temperatures up to 1100 C. Temperature and vacuum environment are maintained while controlling indenter motion, sample position, and providing magnified visual inspection during the test.
Apparatus Tests Thermocouples For Seebeck Inhomogeneity
NASA Technical Reports Server (NTRS)
Burkett, Cecil G., Jr.; Bauserman, Willard A., Jr.; West, James W.
1995-01-01
Automated apparatus reveals sources of error not revealed in calibration. Computer-controlled apparatus detects and measures Seebeck inhomogeneities in sheathed thermocouples. Measures thermocouple output voltage as function of position of probe along sharp gradient of temperature. Abnormal variations in voltage-versus-position data indicative of Seebeck inhomogeneities. Prototype for development of standard method and equipment for routine acceptance/rejection testing of sheathed thermocouples in industrial and research laboratories.
Multiple feedback control apparatus for power conditioning equipment
NASA Technical Reports Server (NTRS)
Biess, John (Inventor); Yu, Yuan (Inventor)
1977-01-01
An improved feedback control system to govern the cyclic operation of the power switch of a non-dissipative power conditioning equipment. The apparatus includes two or three control loops working in unison. The first causes the output DC level to be compared with a reference, and the error amplified for control purposes. The second utilizes the AC component of the voltage across the output filter inductor or the current through the output filter capacitor, and the third loop senses the output transients.
Apparatus and method to inject a reductant into an exhaust gas feedstream
Viola, Michael B [Macomb Township, MI
2009-09-22
An exhaust aftertreatment system for an internal combustion engine is provided including an apparatus and method to inject a reductant into the exhaust gas feedstream. Included is a fuel metering device adapted to inject reductant into the exhaust gas feedstream and a controllable pressure regulating device. A control module is operatively connected to the reductant metering device and the controllable pressure regulating device, and, adapted to effect flow of reductant into the exhaust gas feedstream over a controllable flow range.
Rock sampling. [apparatus for controlling particle size
NASA Technical Reports Server (NTRS)
Blum, P. (Inventor)
1971-01-01
An apparatus for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The device includes grinding means for cutting grooves in the rock surface and to provide a grouping of thin, shallow, parallel ridges and cutter means to reduce these ridges to a powder specimen. Collection means is provided for the powder. The invention relates to rock grinding and particularly to the sampling of rock specimens with good size control.
Automatic control of liquid cooling garment by cutaneous and external auditory meatus temperatures
NASA Technical Reports Server (NTRS)
Fulcher, C. W. G. (Inventor)
1971-01-01
An automatic control apparatus for a liquid cooling garment is described that is responsive to actual physiological needs during work and rest periods of a man clothed in the liquid cooling garment. Four skin temperature readings and a reading taken at the external portion of the auditory meatus are added and used in the control signal for a temperature control valve regulating inlet water temperature for the liquid cooling garment. The control apparatus comprises electronic circuits to which the temperatures are applied as control signals and an electro-pneumatic transducer attached to the control valve.
Laser fusion pulse shape controller
Siebert, Larry D.
1977-01-01
An apparatus for controlling the pulse shape, i.e., the pulse duration and intensity pattern, of a pulsed laser system, and which is particularly well adapted for controlling the pellet ignition pulse in a laser-driven fusion reaction system. The apparatus comprises a laser generator for providing an optical control pulse of the shape desired, a pulsed laser triggered by the control pulse, and a plurality of optical Kerr-effect gates serially disposed at the output of the pulsed laser and selectively triggered by the control pulse to pass only a portion of the pulsed laser output generally corresponding in shape to the control pulse.
Apparatus for growing crystals
NASA Technical Reports Server (NTRS)
Jasinski, Thomas J. (Inventor); Witt, August F. (Inventor)
1986-01-01
An improved apparatus and method for growing crystals from a melt employing a heat pipe, consisting of one or more sections, each section serving to control temperature and thermal gradients in the crystal as it forms inside the pipe.
Crankshaft position sensing with combined starter alternator
Brandenburg, Larry Raymond; Miller, John Michael
2000-06-13
A crankshaft position sensing apparatus for use with an engine (16) having a combined starter/alternator assembly (18). The crankshaft position sensing apparatus includes a tone ring (38) with a sensor (36) and bandpass filter (46), having a cylinder identification input from a camshaft sensor (48), and a gain limiter (54). The sensing apparatus mounts near the rotor (30) of the combined starter/alternator assembly (18). The filtered crankshaft position signal can then be input into a vehicle system controller (58) and an inner loop controller (60). The starter/alternator assembly (18) in combination with an internal combustion engine is particularly useful for a hybrid electric vehicle system.
Method and apparatus for controlling a microturbine
Garces, Luis Jose; Cardinal, Mark Edward; Sinha, Gautam; Dame, Mark Edward
2005-08-02
An apparatus for controlling a microturbine, the apparatus including: a rectifier adapted for converting at least one generated voltage from the microturbine to a DC link voltage; an inverter adapted for converting the DC link voltage to at least one inverter output voltage, the at least one inverter output voltage being electrically coupled to an external power bus; a starter drive adapted for converting at least one starter input voltage to at least one starter output voltage, the at least one starter input voltage being electrically coupled to the external power bus, the at least one starter output voltage being electrically coupled to the microturbine.
Demand illumination control apparatus
NASA Technical Reports Server (NTRS)
Warren, Carl (Inventor); Arline, Jimmie (Inventor); LaPalme, Julius (Inventor)
1981-01-01
Solar illuminating compensating apparatus is disclosed whereby the interior of a building is illuminated to a substantially constant, predetermined level of light intensity by a combination of natural illumination from the sun and artificial illumination from electricity wherein the intensity of said artificial illumination is controlled by fully electronic means which increases the level of artificial illumination when the natural illumination is inadequate and vice versa.
Polarization Imaging Apparatus with Auto-Calibration
NASA Technical Reports Server (NTRS)
Zou, Yingyin Kevin (Inventor); Zhao, Hongzhi (Inventor); Chen, Qiushui (Inventor)
2013-01-01
A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.
Polarization imaging apparatus with auto-calibration
Zou, Yingyin Kevin; Zhao, Hongzhi; Chen, Qiushui
2013-08-20
A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5.degree., a second variable phase retarder with its optical axis aligned 45.degree., a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively. Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.
NASA Technical Reports Server (NTRS)
Liu, Ketao (Inventor); Uetrecht, David S. (Inventor)
2002-01-01
A method, apparatus, article of manufacture, and a memory structure for compensating for instrument induced spacecraft jitter is disclosed. The apparatus comprises a spacecraft control processor for producing an actuator command signal, a signal generator, for producing a cancellation signal having at least one harmonic having a frequency and an amplitude substantially equal to that of a disturbance harmonic interacting with a spacecraft structural resonance and a phase substantially out of phase with the disturbance harmonic interacting with the spacecraft structural resonance, and at least one spacecraft control actuator, communicatively coupled to the spacecraft control processor and the signal generator for inducing satellite motion according to the actuator command signal and the cancellation signal. The method comprises the steps of generating a cancellation signal having at least one harmonic having a frequency and an amplitude substantially equal to that of a disturbance harmonic interacting with a spacecraft structural resonance and a phase substantially out of phase with the disturbance harmonic interacting with the spacecraft structural resonance, and providing the cancellation signal to a spacecraft control actuator. The apparatus comprises a storage device tangibly embodying the method steps described above.
Brooks, J.N.; Mattas, R.F.
1983-12-21
It is an object of the present invention to provide an apparatus for removing impurities from the plasma in a fusion reactor without an external vacuum pumping system. It is also an object of the present invention to provide an apparatus for removing the helium ash from a fusion reactor. It is another object of the present invention to provide an apparatus which removes helium ash and minimizes tritium recycling and inventory.
Apparatus for Measurements of Time and Space Correlation
NASA Technical Reports Server (NTRS)
Favre, Alexandre; Gaviglio, J; Dumas, R
1955-01-01
A brief review is made of improvements to an experimental apparatus for time and space correlation designed for study of turbulence. Included is a description of the control of the measurements and a few particular applications.
Portable Runway Intersection Display and Monitoring System
NASA Technical Reports Server (NTRS)
Elrod, Susan Vinz (Inventor); Dabney, Richard W. (Inventor)
2011-01-01
Systems, methods and apparatus are provided through which an apparatus located on an airfield provides information to pilots in aircraft on the ground and simultaneously gathers information on the motion and position of the aircraft for controllers.
NASA Technical Reports Server (NTRS)
Derkacs, Thomas (Inventor); Fetheroff, Charles W. (Inventor); Matay, Istvan M. (Inventor); Toth, Istvan J. (Inventor)
1982-01-01
Although the method and apparatus of the present invention can be utilized to apply either a uniform or a nonuniform covering of material over many different workpieces, the apparatus (20) is advantageously utilized to apply a thermal barrier covering (64) to an airfoil (22) which is used in a turbine engine. The airfoil is held by a gripper assembly (86) while a spray gun (24) is effective to apply the covering over the airfoil. When a portion of the covering has been applied, a sensor (28) is utilized to detect the thickness of the covering. A control apparatus (32) compares the thickness of the covering of material which has been applied with the desired thickness and is subsequently effective to regulate the operation of the spray gun to adaptively apply a covering of a desired thickness with an accuracy of at least plus or minus 0.0015 inches (1.5 mils) despite unanticipated process variations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, David R; Bartholomew, David B; Moon, Justin
2009-09-08
An apparatus for fixing computational latency within a deterministic region on a network comprises a network interface modem, a high priority module and at least one deterministic peripheral device. The network interface modem is in communication with the network. The high priority module is in communication with the network interface modem. The at least one deterministic peripheral device is connected to the high priority module. The high priority module comprises a packet assembler/disassembler, and hardware for performing at least one operation. Also disclosed is an apparatus for executing at least one instruction on a downhole device within a deterministic region,more » the apparatus comprising a control device, a downhole network, and a downhole device. The control device is near the surface of a downhole tool string. The downhole network is integrated into the tool string. The downhole device is in communication with the downhole network.« less
Apparatus and Process for Controlled Nanomanufacturing Using Catalyst Retaining Structures
NASA Technical Reports Server (NTRS)
Nguyen, Cattien (Inventor)
2013-01-01
An apparatus and method for the controlled fabrication of nanostructures using catalyst retaining structures is disclosed. The apparatus includes one or more modified force microscopes having a nanotube attached to the tip portion of the microscopes. An electric current is passed from the nanotube to a catalyst layer of a substrate, thereby causing a localized chemical reaction to occur in a resist layer adjacent the catalyst layer. The region of the resist layer where the chemical reaction occurred is etched, thereby exposing a catalyst particle or particles in the catalyst layer surrounded by a wall of unetched resist material. Subsequent chemical vapor deposition causes growth of a nanostructure to occur upward through the wall of unetched resist material having controlled characteristics of height and diameter and, for parallel systems, number density.
Code of Federal Regulations, 2010 CFR
2010-01-01
... room with viewing and intercom systems to permit continuous observation of the patient or the human... treatment room by a door at each entrance. (b) A licensee shall equip each entrance to the treatment room... cycle unless each treatment room entrance door is closed; (2) Cause the source(s) to be shielded when an...
Tamaki, S; Kawazoe, K; Yagihara, T; Abe, T
1992-02-01
The effect of pulsatile pulmonary flow after the modified Fontan procedure was examined in a model that simulated the right heart. An inlet overflow tank (preload), axial pulsatile pump, Wind-Kessel model (afterload), and an outlet overflow tank were connected in series. The standard conditions were flow 2.00 l/min with 12 mm Hg preload pressure, 3.0 Wood units resistance, and an outlet overflow tank pressure at 6 mm Hg. The pump rate was set at 80 beats/min. The simulated pulmonary arterial pressure and pulmonary flow waves produced by this model closely resembled those obtained from patients who had undergone the modified Fontan procedure. All variables except the preload were fixed and changes in pulmonary flow were examined at preload pressures of 8, 12, 15, and 17 mm Hg. As the peak pulmonary arterial pressure increased so did pulmonary flow, until it was greater than during the non-pulsatile state. Because the afterload of this model was fixed, this result suggests that there was a concomitant decrease in resistance. This model indicates that pulsatile pulmonary blood flow is likely to have a beneficial effect on the pulmonary circulation after the modified Fontan procedure.
Bianchi, C; Botta, F; Conte, L; Vanoli, P; Cerizza, L
2008-10-01
This study was undertaken to compare the biological efficacy of different high-dose-rate (HDR) and low-dose-rate (LDR) treatments of gynaecological lesions, to identify the causes of possible nonuniformity and to optimise treatment through customised calculation. The study considered 110 patients treated between 2001 and 2006 with external beam radiation therapy and/or brachytherapy with either LDR (afterloader Selectron, (137)Cs) or HDR (afterloader microSelectron Classic, (192)Ir). The treatments were compared in terms of biologically effective dose (BED) to the tumour and to the rectum (linear-quadratic model) by using statistical tests for comparisons between independent samples. The difference between the two treatments was statistically significant in one case only. However, within each technique, we identified considerable nonuniformity in therapeutic efficacy due to differences in fractionation schemes and overall treatment time. To solve this problem, we created a Microsoft Excel spreadsheet allowing calculation of the optimal treatment for each patient: best efficacy (BED(tumour)) without exceeding toxicity threshold (BED(rectum)). The efficacy of a treatment may vary as a result of several factors. Customised radiobiological evaluation is a useful adjunct to clinical evaluation in planning equivalent treatments that satisfy all dosimetric constraints.
Faucheux, F.; L'Huillier, J.P.; Rouillion, P.; Yvroud, E.; Kessler, M.; Huriet, C.
1982-01-01
The extranephric cleaning by means of hemofiltration and generally operations in extracorporal circulation requires the blood derivation towards a treatment apparatus: filtration by means of hemodialysis, oxygenation. The working principle of the treatment apparatuses does not simply allow to connect the blood flow taken from the patient. A control of the patient is therefore necessary to have a treatment performed in good conditions. The method that we propose consists in weighting the variable containing unit of the apparatus and in subjecting this weight to a value determined by the physician. This value is programmed on the machine before the treatment session. The control is performed by means of an action on the differential flow and allow a precise control of the weight loss of the patient during a treatment in extranephric cleaning by means of hemofiltration.
Chiu, Haw-Yen; Hsu, Hsiu-Yun; Kuo, Li-Chieh; Chang, Jer-Hao; Su, Fong-Chin
2009-08-01
A precise magnitude and timing control of pinch performance is based on accurate feed-forward and feedback control mechanisms. Ratio of peak pinch force and maximum load force during a functional performance is a sensitive parameter to reflect the ability to scale pinch force output according to actual loads. A pinch apparatus was constructed to detect momentary pinch force modulation of 20 subjects with normal hand sensation. The results indicated high intra-class correlation coefficient and small coefficient of variation of the detected force ratio among three repeated tests, which represented that the stability test of the measured response confirmed the feasibility of this apparatus. The force ratio for a 480 g object with a steel surface ranged between 1.77 and 1.98. Normal subjects were able to scale and contribute pinch force precisely to a pinch-holding-up test. This study may provide clinicians a reliable apparatus and method to analyze the recovery of functional sensibility in patients with nerve injuries. Copyright 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
AN APPARATUS FOR THE CULTURE OF WHOLE ORGANS
Lindbergh, C. A.
1935-01-01
An apparatus has been developed which maintains, under controllable conditions, a pulsating circulation of sterile fluid through organs for a length of time limited only by the changes in the organ and in the perfusion fluid. PMID:19870424
Improved apparatus for continuous culture of hydrogen-fixing bacteria
NASA Technical Reports Server (NTRS)
Foster, J. F.; Litchfield, J. H.
1970-01-01
Improved apparatus permits the continuous culture of Hydrogenomonas eutropha. System incorporates three essential subsystems - /1/ environmentally isolated culture vessel, /2/ analytical system with appropriate sensors and readout devices, /3/ control system with feedback responses to each analytical measurement.
Hodges, James L.; Cerkanowicz, Anthony E.
1983-01-01
In a fluidized bed of solid particles having one or more heat exchange tubes immersed therein, the rate of heat transfer between the fluidized particles and a fluid flowing through the immersed heat exchange tubes is controlled by rotating an arcuate shield apparatus about each tube to selectively expose various portions of the tube to the fluidized particles.
Hodges, James L.; Cerkanowicz, Anthony E.
1982-01-01
In a fluidized bed of solid particles having one or more heat exchange tubes immersed therein, the rate of heat transfer between the fluidized particles and a fluid flowing through the immersed heat exchange tubes is controlled by rotating an arcuate shield apparatus about each tube to selectively expose various portions of the tube to the fluidized particles.
Apparatus and method for controlling the temperature of the core of a super-conducting transformer
Golner, Thomas; Pleva, Edward; Mehta, Shirish
2006-10-10
An apparatus for controlling the temperature of a core of a transformer is provided that includes a core, a shield surrounding the core, a cast formed between the core and the shield, and tubing positioned on the shield. The cast directs heat from the core to the shield and cooling fluid is directed through the tubing to cool the shield.
Tuffner, Francis K [Richland, WA; Kintner-Meyer, Michael C. W. [Richland, WA; Hammerstrom, Donald J [West Richland, WA; Pratt, Richard M [Richland, WA
2012-05-22
Battery charging control methods, electric vehicle charging methods, battery charging apparatuses and rechargeable battery systems. According to one aspect, a battery charging control method includes accessing information regarding a presence of at least one of a surplus and a deficiency of electrical energy upon an electrical power distribution system at a plurality of different moments in time, and using the information, controlling an adjustment of an amount of the electrical energy provided from the electrical power distribution system to a rechargeable battery to charge the rechargeable battery.
NASA Astrophysics Data System (ADS)
Olsen, M. K.
2017-10-01
We propose and analyze a nonlinear optical apparatus in which the direction of asymmetric steering is controllable within the apparatus, rather than by adding noise to measurements. Using a nondegenerate parametric oscillator with an injected signal field, we show how the directionality and extent of the steering can be readily controlled for output modes that can be up to one octave apart. The two down-converted modes, which exhibit the greater violations of the steering inequalities, can also be controlled to exhibit asymmetric steering in some regimes.
Mechanisms for employment with robotic extensions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salisbury, Curt Michael; Dullea, Kevin J.
Technologies pertaining to a robotic hand are described herein. A protection apparatus is positioned in a joint of the robotic hand, where movement of a link about the joint is driven by a motor. The protection apparatus absorbs torque about the joint caused by an external force. At least a portion of the robotic hand can be covered by an anthropomorphic skin. An apparatus suitable for controlling operation of the robotic hand is also described herein.
Means and apparatus for throttling a dry pulverized solid material pump
Meyer, J. W.; Daniel, Jr, A. D.; Bonin, J. H.
1982-12-07
Method and apparatus are shown for control of continuous feeding of pulverized material to a high pressure container. A rotor is located within the high pressure container. The pulverized material is fed from a feed hopper through a stationary feed pipe to a vented spin-up zone chamber to a plurality of sprues mounted in the rotor. Control of the pressure within control nozzles downstream from the sprues adjusts the flow rate of coal through the sprues. 9 figs.
Means and apparatus for throttling a dry pulverized solid material pump
Meyer, John W [Palo Alto, CA; Daniel, Jr., Arnold D.; Bonin, John H [Sunnyvale, CA
1982-01-01
Method and apparatus are shown for control of continuous feeding of pulverized material to a high pressure container. A rotor is located within the high pressure container. The pulverized material is fed from a feed hopper through a stationary feed pipe to a vented spin-up zone chamber to a plurality of sprues mounted in the rotor. Control of the pressure within control nozzles downstream from the sprues adjusts the flow rate of coal through the sprues.
NASA Astrophysics Data System (ADS)
Arnold, F.; DeMallie, I.; Florence, L.; Kashinski, D. O.
2015-03-01
This manuscript addresses the design, hardware details, construction, and programming of an apparatus allowing an experimenter to monitor and record high-temperature thermocouple measurements of dynamic systems in real time. The apparatus uses wireless network technology to bridge the gap between a dynamic (moving) sample frame and the static laboratory frame. Our design is a custom solution applied to samples that rotate through large angular displacements where hard-wired and typical slip-ring solutions are not practical because of noise considerations. The apparatus consists of a Raspberry PI mini-Linux computer, an Arduino micro-controller, an Ocean Controls thermocouple multiplexer shield, and k-type thermocouples.
Arnold, F; DeMallie, I; Florence, L; Kashinski, D O
2015-03-01
This manuscript addresses the design, hardware details, construction, and programming of an apparatus allowing an experimenter to monitor and record high-temperature thermocouple measurements of dynamic systems in real time. The apparatus uses wireless network technology to bridge the gap between a dynamic (moving) sample frame and the static laboratory frame. Our design is a custom solution applied to samples that rotate through large angular displacements where hard-wired and typical slip-ring solutions are not practical because of noise considerations. The apparatus consists of a Raspberry PI mini-Linux computer, an Arduino micro-controller, an Ocean Controls thermocouple multiplexer shield, and k-type thermocouples.
NASA Technical Reports Server (NTRS)
Libby, W. F.; Jensen, C. A.; Wood, L. L. (Inventor)
1977-01-01
The apparatus includes a housing for confining a gas at subatmospheric pressure and including a set of reflectors defining an optical cavity. At least one anode and cathode are positioned within the gas. First control means control the voltage applied to the anode and second control means independently control the temperature of the cathode. The pressure of the gas is controlled by a third control means. An intense monochromatic output is achieved by confining the gas in the housing at a controlled pre-determined reduced pressure, independently controlling the temperature of the electron emitting cathode and applying predetermined controlled low voltage to the anode.
Multichannel Brain-Signal-Amplifying and Digitizing System
NASA Technical Reports Server (NTRS)
Gevins, Alan
2005-01-01
An apparatus has been developed for use in acquiring multichannel electroencephalographic (EEG) data from a human subject. EEG apparatuses with many channels in use heretofore have been too heavy and bulky to be worn, and have been limited in dynamic range to no more than 18 bits. The present apparatus is small and light enough to be worn by the subject. It is capable of amplifying EEG signals and digitizing them to 22 bits in as many as 150 channels. The apparatus is controlled by software and is plugged into the USB port of a personal computer. This apparatus makes it possible, for the first time, to obtain high-resolution functional EEG images of a thinking brain in a real-life, ambulatory setting outside a research laboratory or hospital.
Wireless remote monitoring of critical facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Hanchung; Anderson, John T.; Liu, Yung Y.
A method, apparatus, and system are provided for monitoring environment parameters of critical facilities. A Remote Area Modular Monitoring (RAMM) apparatus is provided for monitoring environment parameters of critical facilities. The RAMM apparatus includes a battery power supply and a central processor. The RAMM apparatus includes a plurality of sensors monitoring the associated environment parameters and at least one communication module for transmitting one or more monitored environment parameters. The RAMM apparatus is powered by the battery power supply, controlled by the central processor operating a wireless sensor network (WSN) platform when the facility condition is disrupted. The RAMM apparatusmore » includes a housing prepositioned at a strategic location, for example, where a dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance.« less
On the Development of a Unique Arc Jet Test Apparatus for Control Surface Seal Evaluations
NASA Technical Reports Server (NTRS)
Finkbeiner, Joshua R.; Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; Robbie, Malcolm; Baker, Gus; Erker, Arthur
2004-01-01
NASA Glenn has developed a unique test apparatus capable of evaluating control surface seal and flap designs under simulated reentry heating conditions in NASA Johnson's arc jet test facility. The test apparatus is capable of testing a variety of seal designs with a variety of control surface materials and designs using modular components. The flap angle can be varied during testing, allowing modification of the seal environment while testing is in progress. The flap angle is varied using an innovative transmission system which limits heat transfer from the hot flap structure to the motor, all while keeping the components properly aligned regardless of thermal expansion. A combination of active and passive cooling is employed to prevent thermal damage to the test fixture while still obtaining the target seal temperature.
Method and apparatus for generating radiation utilizing DC to AC conversion with a conductive front
Dawson, John M.; Mori, Warren B.; Lai, Chih-Hsiang; Katsouleas, Thomas C.
1998-01-01
Method and apparatus for generating radiation of high power, variable duration and broad tunability over several orders of magnitude from a laser-ionized gas-filled capacitor array. The method and apparatus convert a DC electric field pattern into a coherent electromagnetic wave train when a relativistic ionization front passes between the capacitor plates. The frequency and duration of the radiation is controlled by the gas pressure and capacitor spacing.
APPARATUS FOR CHARGING A RECEPTACLE WITH A DENSE SUBLIMATE FORM OF URANIUM CHLORIDE
Davidson, P.H.
1959-08-18
An apparatus for filling a tubular storage receptacle with a dense massive form of uranium chloride is described. The apparatus includes an evacuated housing divided into a vaporizing chamber and a portion adapted to receive the receptacle. A nozzle conducts vaporized uranium chloride from the chamber to the interior of the receptacle. The nozzle is withdrawable to progressively deposit the uranium chloride under controlled conditions to produce a dense sublimate which fills the receptacle.
APPARATUS FOR MINIMIZING ENERGY LOSSES FROM MAGNETICALLY CONFINED VOLUMES OF HOT PLASMA
Post, R.F.
1961-10-01
An apparatus is described for controlling electron temperature in plasma confined in a Pyrotron magnetic containment field. Basically the device comprises means for directing low temperature electrons to the plasma in controlled quantities to maintain a predetermined optimum equilibrium electron temperature whereat minimum losses of plasma ions due to ambipolar effects and energy damping of the ions due to dynamical friction with the electrons occur. (AEC)
Manufacturing Diamond Under Very High Pressure
NASA Technical Reports Server (NTRS)
Voronov, Oleg
2007-01-01
A process for manufacturing bulk diamond has been made practical by the invention of the High Pressure and Temperature Apparatus capable of applying the combination of very high temperature and high pressure needed to melt carbon in a sufficiently large volume. The apparatus includes a reaction cell wherein a controlled static pressure as high as 20 GPa and a controlled temperature as high as 5,000 C can be maintained.
Songstad, Nils Thomas; Johansen, David; How, Ole-Jacob; Kaaresen, Per Ivar; Ytrehus, Kirsti; Acharya, Ganesh
2014-01-01
There is an increased risk of heart failure and pulmonary edema in pregnancies complicated by hypertensive disorders. However, in a previous study we found that pregnancy protects against fibrosis and preserves angiogenesis in a rat model of angiotensin II induced cardiac hypertrophy. In this study we test the hypothesis that pregnancy protects against negative effects of increased afterload. Pregnant (gestational day 5.5-8.5) and non-pregnant Wistar rats were randomized to transverse aortic constriction (TAC) or sham surgery. After 14.2 ± 0.14 days echocardiography was performed. Aortic blood pressure and left ventricular (LV) pressure-volume loops were obtained using a conductance catheter. LV collagen content and cardiomyocyte circumference were measured. Myocardial gene expression was assessed by real-time polymerase chain reaction. Heart weight was increased by TAC (p<0.001) but not by pregnancy. Cardiac myocyte circumference was larger in pregnant compared to non-pregnant rats independent of TAC (p = 0.01), however TAC per se did not affect this parameter. Collagen content in LV myocardium was not affected by pregnancy or TAC. TAC increased stroke work more in pregnant rats (34.1 ± 2.4 vs 17.5 ± 2.4 mmHg/mL, p<0.001) than in non-pregnant (28.2 ± 1.7 vs 20.9 ± 1.5 mmHg/mL, p = 0.06). However, it did not lead to overt heart failure in any group. In pregnant rats, α-MHC gene expression was reduced by TAC. Increased in the expression of β-MHC gene was higher in pregnant (5-fold) compared to non-pregnant rats (2-fold) after TAC (p = 0.001). Nine out of the 19 genes related to cardiac remodeling were affected by pregnancy independent of TAC. This study did not support the hypothesis that pregnancy is cardioprotective against the negative effects of increased afterload. Some differences in cardiac structure, function and gene expression between pregnant and non-pregnant rats following TAC indicated that afterload increase is less tolerated in pregnancy.
SU-F-T-13: Transit Dose Comparisons for Co-60 and Ir-192 HDR Sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gimenez-Alventosa, V; Ballester, F; Vijande, J
Purpose: The purpose of this study is to compare the transit dose due to the movement of high dose rate (HDR) Ir-192 and Co-60 sources along the transfer tube. This is performed by evaluating air-kerma differences in the vicinity of the transfer tube when both sources are moved with the same velocity from a HDR brachytherapy afterloader into a patient. Methods: Monte Carlo simulations have been performed using PENELOPE2014. mHDR-v2 and Flexisource sources have been considered. Collisional kerma has been scored. The sources were simulated within a plastic catheter located in an infinite air phantom. The movement of the seedmore » was included by displacing their positions along the connecting catheter from z=−75 cm to z=+75 cm and combining them. Backscatter from the afterloader and the patient was not considered. Since modern afterloaders like Flexitron (Elekta) or Saginova (Bebig) are able to use equally Ir-192 and Co-60 sources it was assumed that both sources are displaced with equal speed. Typical content activity values were provided by the manufacturer (460 GBq for Ir-192 and 75 GBq for Co-60). Results: 2D distributions were obtained with type-A uncertainties (k=2) less than 0.01%. From those, the air kerma ratio Co-60/Ir-192 was evaluated weighted by their corresponding activities. It was found that it varies slowly with distance (less than 10% variation) but strongly in time due to the shorter half-life of the Ir-192 (73.83 days). The maximum ratio is located close to the catheter with a value of 0.57 when both sources are installed by the manufacturer, while increasing up to 1.25 at the end of the recommended working life (90 days) of the Ir-192 source. Conclusion: Air-kerma ratios are almost constant (0.51–0.57) in the vicinity of the source. Nevertheless, air-kerma ratios increase rapidly whenever the Ir-192 is approaching the end of its life.« less
ERIC Educational Resources Information Center
Sievers, Dennis, Ed.
1986-01-01
Describes apparatus for use in high school chemistry instruction. Provides instructions and lists of materials needed for building a homemade sand bath for use in experiments that demonstrate the slow evaporation of a solvent. Plans for the construction of a low-cost conductivity apparatus are also included. (TW)
Lubitz, Andrea L; Sjoholm, Lars O; Goldberg, Amy; Pathak, Abhijit; Santora, Thomas; Sharp, Thomas E; Wallner, Markus; Berretta, Remus M; Poole, Lauren A; Wu, Jichuan; Wolfson, Marla R
2017-02-01
Hemorrhagic shock and pneumonectomy causes an acute increase in pulmonary vascular resistance (PVR). The increase in PVR and right ventricular (RV) afterload leads to acute RV failure, thus reducing left ventricular (LV) preload and output. Inhaled nitric oxide (iNO) lowers PVR by relaxing pulmonary arterial smooth muscle without remarkable systemic vascular effects. We hypothesized that with hemorrhagic shock and pneumonectomy, iNO can be used to decrease PVR and mitigate right heart failure. A hemorrhagic shock and pneumonectomy model was developed using sheep. Sheep received lung protective ventilatory support and were instrumented to serially obtain measurements of hemodynamics, gas exchange, and blood chemistry. Heart function was assessed with echocardiography. After randomization to study gas of iNO 20 ppm (n = 9) or nitrogen as placebo (n = 9), baseline measurements were obtained. Hemorrhagic shock was initiated by exsanguination to a target of 50% of the baseline mean arterial pressure. The resuscitation phase was initiated, consisting of simultaneous left pulmonary hilum ligation, via median sternotomy, infusion of autologous blood and initiation of study gas. Animals were monitored for 4 hours. All animals had an initial increase in PVR. PVR remained elevated with placebo; with iNO, PVR decreased to baseline. Echo showed improved RV function in the iNO group while it remained impaired in the placebo group. After an initial increase in shunt and lactate and decrease in SvO2, all returned toward baseline in the iNO group but remained abnormal in the placebo group. These data indicate that by decreasing PVR, iNO decreased RV afterload, preserved RV and LV function, and tissue oxygenation in this hemorrhagic shock and pneumonectomy model. This suggests that iNO may be a useful clinical adjunct to mitigate right heart failure and improve survival when trauma pneumonectomy is required.
Haemers, Peter; Sutherland, George; Cikes, Maja; Jakus, Nina; Holemans, Patricia; Sipido, Karin R; Willems, Rik; Claus, Piet
2015-11-01
An acute increase in blood pressure is associated with the occurrence of premature ventricular complexes (PVCs). We aimed to study the timing of these PVCs with respect to afterload-induced changes in myocardial deformation in a controlled, preclinically relevant, novel closed-chest pig model. An acute left ventricular (LV) afterload challenge was induced by partial balloon inflation in the descending aorta, lasting 5-10 heartbeats (8 pigs; 396 inflations). Balloon inflation enhanced the reflected wave (augmentation index 30% ± 8% vs 59% ± 6%; P < .001), increasing systolic central blood pressure by 35% ± 4%. This challenge resulted in a more abrupt LV pressure decline, which was delayed beyond ventricular repolarization (rate of pressure decline 0.16 ± 0.01 mm Hg/s vs 0.27 ± 0.04 mm Hg/ms; P < .001 and interval T-wave to peak pressure 1 ± 12 ms vs 36 ± 9 ms; P = .008), during which the velocity of myocardial shortening at the basal septum increased abruptly (ie, postsystolic shortening) (peak strain rate -0.6 ± 0.5 s(-1) vs -2.5 ± 0.8 s(-1); P < .001). It is exactly at this time of LV pressure decline, with increased postsystolic shortening, and not at peak pressure, that PVCs occur (22% of inflations). These PVCs preferentially occurred at the basal and apical segments. In the same regions, monophasic action potentials demonstrated the appearance of delayed afterdepolarization-like transient depolarizations as origin of PVCs. An acute blood pressure increase results in a more abrupt LV pressure decline, which is delayed after ventricular repolarization. This has a profound effect on myocardial mechanics with enhanced postsystolic shortening. Coincidence with induced transient depolarizations and PVCs provides support for the mechanoelectrical origin of pressure-induced premature beats. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Honda, N; Inamoto, T; Nogawa, M; Takatani, S
1999-03-01
An ultracompact, completely implantable permanent use electromechanical ventricular assist device (VAD) and total artificial heart (TAH) intended for 50-60 kg size patients have been developed. The TAH and VAD share a miniature electromechanical actuator that comprises a DC brushless motor and a planetary roller screw. The rotational force of the motor is converted into the rectilinear force of the roller screw to actuate the blood pump. The TAH is a one piece design with left and right pusher plate type blood pumps sandwiching an electromechanical actuator. The VAD is one half of the TAH with the same actuator but a different pump housing and a backplate. The blood contacting surfaces, including those of the flexing diaphragm and pump housing, of both the VAD and TAH were made of biocompatible polyurethane. The diameter, thickness, volume, and weight of the VAD are 90 mm, 56 mm, 285 cc, and 380 g, respectively, while those of the TAH are 90 mm, 73 mm, 400 cc, and 440 g, respectively. The design stroke volume of both the VAD and TAH is 60 cc with the stroke length being 12 mm. The stroke length and motor speed are controlled solely based on the commutation signals of the motor. An in vitro study revealed that a maximum pump flow of 7.5 L/min can be obtained with a pump rate of 140 bpm against a mean afterload of 100 mm Hg. The power requirement ranged from 4 to 6 W to deliver a 4-5 L/min flow against a 100 mm Hg afterload with the electrical-to-hydraulic efficiency being 19-20%. Our VAD and TAH are the smallest of the currently available devices and suitable for bridge to transplant application as well as for permanent circulatory support of 50-60 kg size patients.
A Simple Temperature Gradient Apparatus To Determine Thermal Preference in "Daphnia."
ERIC Educational Resources Information Center
Fenske, Christiane; McCauley, Robert
2002-01-01
Explores the dominant factor controlling the distribution of Daphnia. Describes components of a temperature gradient apparatus that can be assembled from materials readily obtainable in the laboratory and hardware stores. Investigates whether the mean depth of Daphnia is determined by temperature. (KHR)
Material-controlled dynamic vacuum insulation
Benson, D.K.; Potter, T.F.
1996-10-08
A compact vacuum insulation panel is described comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber includes apparatus and methods for enabling and disabling, or turning ``on`` and ``off`` the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls. 25 figs.
Material-controlled dynamic vacuum insulation
Benson, David K.; Potter, Thomas F.
1996-10-08
A compact vacuum insulation panel comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber includes apparatus and methods for enabling and disabling, or turning "on" and "off" the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls.
Radiation-controlled dynamic vacuum insulation
Benson, David K.; Potter, Thomas F.
1995-01-01
A compact vacuum insulation panel comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber that includes apparatus and methods for enabling and disabling, or turning "on" and "off" the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls.
Radiation-controlled dynamic vacuum insulation
Benson, D.K.; Potter, T.F.
1995-07-18
A compact vacuum insulation panel is described comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber that includes apparatus and methods for enabling and disabling, or turning ``on`` and ``off`` the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls. 25 figs.
A new diode laser acupuncture therapy apparatus
NASA Astrophysics Data System (ADS)
Li, Chengwei; Huang, Zhen; Li, Dongyu; Zhang, Xiaoyuan
2006-06-01
Since the first laser-needles acupuncture apparatus was introduced in therapy, this kind of apparatus has been well used in laser biomedicine as its non-invasive, pain- free, non-bacterium, and safetool. The laser acupuncture apparatus in this paper is based on single-chip microcomputer and associated by semiconductor laser technology. The function like traditional moxibustion including reinforcing and reducing is implemented by applying chaos method to control the duty cycle of moxibustion signal, and the traditional lifting and thrusting of acupuncture is implemented by changing power output of the diode laser. The radiator element of diode laser is made and the drive circuit is designed. And chaos mathematic model is used to produce deterministic class stochastic signal to avoid the body adaptability. This function covers the shortages of continuous irradiation or that of simple disciplinary stimulate signal, which is controlled by some simple electronic circuit and become easily adjusted by human body. The realization of reinforcing and reducing of moxibustion is technological innovation in traditional acupuncture coming true in engineering.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asano, M.
1979-08-28
The invention discloses an emission control apparatus for internal combustion engine includes an exhaust composition sensor to sense the mixture ratio, a circuit for clamping the mixture ratio to a predetermined constant value to prevent the mixture from becoming too rich or too lean when a failure should occur in the control loop, for example, in the exhaust composition sensor failure and a circuit for interrupting the clamping circuit when the engine operating condition is such that the sensor is caused to produce low voltage signals although the sensor is functioning properly.
Triply redundant integrated navigation and asset visibility system
Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN
2011-11-29
Methods and apparatus are described for a navigation system. A method includes providing a global positioning system fix having a plurality of tracking parameters; providing a theater positioning system fix; monitoring the plurality of tracking parameters for predetermined conditions; and, when the predetermined conditions are met, sending a notifying signal and switching to the theater positioning system fix as a primary fix. An apparatus includes a system controller; a global positioning system receiver coupled to the system controller; a radio frequency locating receiver coupled to the system controller; and an operator interface coupled to the system controller.
Triply redundant integrated navigation and asset visibility system
Smith, Stephen F.; Moore, James A.
2013-01-22
Methods and apparatus are described for a navigation system. A method includes providing a global positioning system fix having a plurality of tracking parameters; providing a theater positioning system fix; monitoring the plurality of tracking parameters for predetermined conditions; and, when the predetermined conditions are met, sending a notifying signal and switching to the theater positioning system fix as a primary fix. An apparatus includes a system controller; a global positioning system receiver coupled to the system controller; a radio frequency locating receiver coupled to the system controller; and an operator interface coupled to the system controller.
Apparatus for controlling fluid flow in a conduit wall
Glass, S. Jill; Nicolaysen, Scott D.; Beauchamp, Edwin K.
2003-05-13
A frangible rupture disk and mounting apparatus for use in blocking fluid flow, generally in a fluid conducting conduit such as a well casing, a well tubing string or other conduits within subterranean boreholes. The disk can also be utilized in above-surface pipes or tanks where temporary and controllable fluid blockage is required. The frangible rupture disk is made from a pre-stressed glass with controllable rupture properties wherein the strength distribution has a standard deviation less than approximately 5% from the mean strength. The frangible rupture disk has controllable operating pressures and rupture pressures.
Apparatus for use in rapid and accurate controlled-potential coulometric analysis
Frazzini, Thomas L.; Holland, Michael K.; Pietri, Charles E.; Weiss, Jon R.
1981-01-01
An apparatus for controlled-potential coulometric analysis of a solution includes a cell to contain the solution to be analyzed and a plurality of electrodes to contact the solution in the cell. Means are provided to stir the solution and to control the atmosphere above it. A potentiostat connected to the electrodes controls potential differences among the electrodes. An electronic circuit connected to the potentiostat provides analog-to-digital conversion and displays a precise count of charge transfer during a desired chemical process. This count provides a measure of the amount of an unknown substance in the solution.
Electromagnetic microforging apparatus for low-cost fabrication of molds for microlens arrays
NASA Astrophysics Data System (ADS)
Pribošek, Jaka; Diaci, Janez
2015-06-01
This study addresses the problem of low-cost microlens fabrication and outlines the development of a novel microforging apparatus for microlens mold fabrication. The apparatus consists of an electromagnetic impact tool which strikes a piston with a hardened steel ball into a workpiece. The impact creates a spherical indentation which serves as a lens cavity. The microforging apparatus is controlled by a microprocessor control unit communicating with a personal computer and enables on-the-fly variation of electromagnetic excitation to control the microforging process. We studied the effects of process parameters on the diameter of the fabricated lens cavities inspected by a custom automatic image processing algorithm. Different microforging regimes are analyzed and discussed. The surface quality of fabricated cavities has been inspected by confocal microscopy and the influence of fill factor on sphericity error has been studied. The proposed microforging method enables the fabrication of molds with 100% fill factor, surface roughness as low as Ra 0.15 µm and sphericity error lower than 0.5 µm. The fabricated microlens arrays exhibit nearly diffraction-limited performance, offering a wide range of possible applications. We believe this study provides access to microoptical technology for smaller optical and computer vision laboratories.
Apparatus for precision focussing and positioning of a beam waist on a target
NASA Technical Reports Server (NTRS)
Lynch, Dana H. (Inventor); Gunter, William D. (Inventor); Mcalister, Kenneth W. (Inventor)
1991-01-01
The invention relates to optical focussing apparatus and, more particularly, to optical apparatus for focussing a highly collimated Gaussian beam which provides independent and fine control over the focus waist diameter, the focus position both along the beam axis and transverse to the beam, and the focus angle. A beam focussing and positioning apparatus provides focussing and positioning for the waist of a waisted beam at a desired location on a target such as an optical fiber. The apparatus includes a first lens, having a focal plane f sub 1, disposed in the path of an incoming beam and a second lens, having a focal plane f sub 2 and being spaced downstream from the first lens by a distance at least equal to f sub 1 + 10 f sub 2, which cooperates with the first lens to focus the waist of the beam on the target. A rotatable optical device, disposed upstream of the first lens, adjusts the angular orientation of the beam waist. The transverse position of the first lens relative to the axis of the beam is varied to control the transverse position of the beam waist relative to the target (a fiber optic as shown) while the relative axial positions of the lenses are varied to control the diameter of the beam waist and to control the axial position of the beam waist. Mechanical controllers C sub 1, C sub 2, C sub 3, C sub 4, and C sub 5 control the elements of the optical system. How seven adjustments can be made to correctly couple a laser beam into an optical fiber is illustrated. Prior art systems employing optical techniques to couple a laser beam into an optical fiber or other target simply do not provide the seven necessary adjustments. The closest known prior art, a Newport coupler, provides only two of the seven required adjustments.
Combustion engine variable compression ratio apparatus and method
Lawrence,; Keith, E [Peoria, IL; Strawbridge, Bryan E [Dunlap, IL; Dutart, Charles H [Washington, IL
2006-06-06
An apparatus and method for varying a compression ratio of an engine having a block and a head mounted thereto. The apparatus and method includes a cylinder having a block portion and a head portion, a piston linearly movable in the block portion of the cylinder, a cylinder plug linearly movable in the head portion of the cylinder, and a valve located in the cylinder plug and operable to provide controlled fluid communication with the block portion of the cylinder.
Method and apparatus for generating radiation utilizing DC to AC conversion with a conductive front
Dawson, J.M.; Mori, W.B.; Lai, C.H.; Katsouleas, T.C.
1998-07-14
Method and apparatus ar disclosed for generating radiation of high power, variable duration and broad tunability over several orders of magnitude from a laser-ionized gas-filled capacitor array. The method and apparatus convert a DC electric field pattern into a coherent electromagnetic wave train when a relativistic ionization front passes between the capacitor plates. The frequency and duration of the radiation is controlled by the gas pressure and capacitor spacing. 4 figs.
Apparatus for Screening Multiple Oxygen-Reduction Catalysts
NASA Technical Reports Server (NTRS)
Whitacre, Jay; Narayanan, Sekharipuram
2009-01-01
An apparatus that includes an array of multiple electrodes has been invented as a means of simultaneously testing multiple materials for their utility as oxygen-reduction catalysts in fuel cells. The apparatus ensures comparability of test results by exposing all the catalyst-material specimens to the same electrolytic test solution at the same potential. Heretofore, it has been possible to test only one specimen at a time, using a precise rotating disk electrode that provides a controlled flux of solution to the surface of the specimen.
Ultrastructure of meristem and root cap of pea seedlings under spaceflight conditions
NASA Technical Reports Server (NTRS)
Sytnyk, K. M.; Kordyum, E. L.; Bilyavska, N. O.; Tarasenko, V. O.
1983-01-01
Data of electron microscopic analysis of meristem and root cap of pea seedlings grown aboard the Salyut-6 orbital research station in the Oazis apparatus and in the laboratory are presented. The main morphological and anatomical characteristics of the test and control plants are shown to be similar. At the same time, some differences are found in the structural and functional organization of the experimental cells as compared to the controls. They concern first of all the plastic apparatus, mitochondria and Golgi apparatus. It is assumed that cell function for certain periods of weightlessness on the whole ensures execution of the cytodifferentiation programs genetically determined on the Earth. Biochemical and physiological processes vary rather markedly due to lack of initially rigorous determination.
Apparatus and methods for humidity control
NASA Technical Reports Server (NTRS)
Dinauer, William R. (Inventor); Otis, David R. (Inventor); El-Wakil, Mohamed M. (Inventor); Vignali, John C. (Inventor); Macaulay, Philip D. (Inventor)
1994-01-01
Apparatus is provided which controls humidity in a gas. The apparatus employs a porous interface that is preferably a manifolded array of stainless steel tubes through whose porous surface water vapor can pass. One side of the porous interface is in contact with water and the opposing side is in contact with gas whose humidity is being controlled. Water vapor is emitted from the porous surface of the tubing into the gas when the gas is being humidified, and water vapor is removed from the gas through the porous surfaces when the gas is being dehumidified. The temperature of the porous interface relative to the gas temperature determines whether humidification or dehumidification is being carried out. The humidity in the gas is sensed and compared to the set point humidity. The water temperature, and consequently the porous interface temperature, are automatically controlled in response to changes in the gas humidity level above or below the set point. Any deviation from the set point humidity is thus corrected.
Casting fine grained, fully dense, strong inorganic materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Sam W.; Spencer, Larry S.; Phillips, Michael R.
2015-11-24
Methods and apparatuses for casting inorganic materials are provided. The inorganic materials include metals, metal alloys, metal hydrides and other materials. Thermal control zones may be established to control the propagation of a freeze front through the casting. Agitation from a mechanical blade or ultrasonic energy may be used to reduce porosity and shrinkage in the casting. After solidification of the casting, the casting apparatus may be used to anneal the cast part.
Ryon, Allen D.; Haas, Paul A.; Vavruska, John S.
1984-01-01
The present invention is directed to a method and apparatus for making a population of dense, closely size-controlled microspheres by sol-gel procedures wherein said microspheres are characterized by a significant percentage of said population being within a predetermined, relatively narrow size range. Microsphere populations thus provided are useful in vibratory-packed processes for nuclear fuels to be irradiated in LWR- and FBR-type nuclear reactors.
ARC length control for plasma welding
NASA Technical Reports Server (NTRS)
Iceland, William F. (Inventor)
1988-01-01
A control system to be used with a plasma arc welding apparatus is disclosed. The plasma arc welding apparatus includes a plasma arc power supply, a contactor, and an electrode assembly for moving the electrode relative to a work piece. The electrode assembly is raised or lowered by a drive motor. The present apparatus includes a plasma arc adapter connected across the power supply to measure the voltage across the plasma arc. The plasma arc adapter forms a dc output signal input to a differential amplifier. A second input is defined by an adjustable resistor connected to a dc voltage supply to permit operator control. The differential amplifier forms an output difference signal provided to an adder circuit. The adder circuit then connects with a power amplifier which forms the driving signal for the motor. In addition, the motor connects to a tachometor which forms a feedback signal delivered to the adder to provide damping, therby avoiding servo loop overshoot.
Method and apparatus for reading thermoluminescent phosphors
Braunlich, Peter F.; Tetzlaff, Wolfgang
1987-01-01
An apparatus and method for rapidly reading thermoluminescent phosphors to determine the amount of luminescent energy stored therein. The stored luminescent energy is interpreted as a measure of the total exposure of the thermoluminescent phosphor to ionizing radiation. The thermoluminescent phosphor reading apparatus uses a laser to generate a laser beam. The laser beam power level is monitored by a laser power detector and controlled to maintain the power level nearly constant. A shutter or other laser beam interrupting means is used to control exposure of the thermoluminescent phosphor to the laser beam. The laser beam can be equalized using an optical equalizer so that the laser beam has an approximately uniform power density across the beam. The heated thermoluminescent phosphor emits a visible or otherwise detectable luminescent emission which is measured as an indication of the radiation exposure of the thermoluminescent phosphors. Also disclosed are preferred signal processing and control circuits.
Improved Position Sensor for Feedback Control of Levitation
NASA Technical Reports Server (NTRS)
Hyers, Robert; Savage, Larry; Rogers, Jan
2004-01-01
An improved optoelectronic apparatus has been developed to provide the position feedback needed for controlling the levitation subsystem of a containerless-processing system. As explained, the advantage of this apparatus over prior optoelectronic apparatuses that have served this purpose stems from the use of an incandescent lamp, instead of a laser, to illuminate the levitated object. In containerless processing, a small object to be processed is levitated (e.g., by use of a microwave, low-frequency electromagnetic, electrostatic, or acoustic field) so that it is not in contact with the wall of the processing chamber or with any other solid object during processing. In the case of electrostatic or low-frequency electromagnetic levitation, real-time measurement of the displacement of the levitated object from its nominal levitation position along the vertical axis (and, in some cases, along one or two horizontal axes) is needed for feedback control of the levitating field.
Corrosion detector apparatus for universal assessment of pollution in data centers
Hamann, Hendrik F.; Klein, Levente I.
2015-08-18
A compact corrosion measurement apparatus and system includes an air fan, a corrosion sensor, a temperature sensor, a humidity sensor, a heater element, and an air flow sensor all under control to monitor and maintain constant air parameters in an environment and minimize environmental fluctuations around the corrosion sensor to overcome the variation commonly encountered in corrosion rate measurement. The corrosion measurement apparatus includes a structure providing an enclosure within which are located the sensors. Constant air flow and temperature is maintained within the enclosure where the corrosion sensor is located by integrating a variable speed air fan and a heater with the corresponding feedback loop control. Temperature and air flow control loops ensure that corrosivity is measured under similar conditions in different facilities offering a general reference point that allow a one to one comparison between facilities with similar or different pollution levels.
Method and system for diagnostics of apparatus
NASA Technical Reports Server (NTRS)
Gorinevsky, Dimitry (Inventor)
2012-01-01
Proposed is a method, implemented in software, for estimating fault state of an apparatus outfitted with sensors. At each execution period the method processes sensor data from the apparatus to obtain a set of parity parameters, which are further used for estimating fault state. The estimation method formulates a convex optimization problem for each fault hypothesis and employs a convex solver to compute fault parameter estimates and fault likelihoods for each fault hypothesis. The highest likelihoods and corresponding parameter estimates are transmitted to a display device or an automated decision and control system. The obtained accurate estimate of fault state can be used to improve safety, performance, or maintenance processes for the apparatus.
A programmable control system for salinity has been developed and coupled with a flow-through toxicant exposure system. The resulting apparatus allow study of influences of constant and fluctuating salinity regimes on responses of One organisms exposed to selected pollutants. Con...
Mechanical stimulation in the engineering of heart muscle.
Liaw, Norman Yu; Zimmermann, Wolfram-Hubertus
2016-01-15
Recreating the beating heart in the laboratory continues to be a formidable bioengineering challenge. The fundamental feature of the heart is its pumping action, requiring considerable mechanical forces to compress a blood filled chamber with a defined in- and outlet. Ventricular output crucially depends on venous loading of the ventricles (preload) and on the force generated by the preloaded ventricles to overcome arterial blood pressure (afterload). The rate of contraction is controlled by the spontaneously active sinus node and transmission of its electrical impulses into the ventricles. The underlying principles for these physiological processes are described by the Frank-Starling mechanism and Bowditch phenomenon. It is essential to consider these principles in the design and evaluation of tissue engineered myocardium. This review focuses on current strategies to evoke mechanical loading in hydrogel-based heart muscle engineering. Copyright © 2015. Published by Elsevier B.V.
Turan, Sifa; Turan, Ozhan M
2018-03-15
The ductus venosus is a fetal vessel that functions importantly in the transfer of oxygen-and nutrient-rich blood from the umbilical vein to vital organs. Its control under active regulation and its anatomy result in a flow-velocity profile that is typically forward throughout the cardiac cycle. This forward cardiac function reflects afterload, cardiac contractility, compliance, and vascular volume changes. Ductus venosus assessment gives valuable information under different fetal conditions. For example, during first trimester screening, an abnormal ductus venosus measurement changes the screening result. Assessment of ductus venosus in twin-to-twin transfusion syndrome is an essential element of staging. In fetal growth restriction, an abnormal waveform mandates imminent delivery. In this review, we will discuss the role of ductus venosus assessment and its role in antenatal management and outcome prediction in certain fetal conditions throughout pregnancy.
Harmony Behind the Trumped-Shaped Vessel: the Essential Role of the Ductus Venosus in Fetal Medicine
Turan, Sifa; Turan, Ozhan M.
2018-01-01
The ductus venosus is a fetal vessel that functions importantly in the transfer of oxygen-and nutrient-rich blood from the umbilical vein to vital organs. Its control under active regulation and its anatomy result in a flow-velocity profile that is typically forward throughout the cardiac cycle. This forward cardiac function reflects afterload, cardiac contractility, compliance, and vascular volume changes. Ductus venosus assessment gives valuable information under different fetal conditions. For example, during first trimester screening, an abnormal ductus venosus measurement changes the screening result. Assessment of ductus venosus in twin-to-twin transfusion syndrome is an essential element of staging. In fetal growth restriction, an abnormal waveform mandates imminent delivery. In this review, we will discuss the role of ductus venosus assessment and its role in antenatal management and outcome prediction in certain fetal conditions throughout pregnancy. PMID:29553462
Master-slave micromanipulator apparatus
Morimoto, A.K.; Kozlowski, D.M.; Charles, S.T.; Spalding, J.A.
1999-08-31
An apparatus is disclosed based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion. Precision linear stages along with precision linear motors, encoders, and controls provide a robotics system. The motors can be positioned in a remote location by incorporating a set of bellows on the motors and can be connected through a computer controller that will allow one to be a master and the other one to be a slave. Position information from the master can be used to control the slave. Forces of interaction of the slave with its environment can be reflected back to the motor control of the master to provide a sense of force sensed by the slave. Forces import onto the master by the operator can be fed back into the control of the slave to reduce the forces required to move it. 12 figs.
Master-slave micromanipulator apparatus
Morimoto, Alan K.; Kozlowski, David M.; Charles, Steven T.; Spalding, James A.
1999-01-01
An apparatus based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion. Precision linear stages along with precision linear motors, encoders, and controls provide a robotics system. The motors can be positioned in a remote location by incorporating a set of bellows on the motors and can be connected through a computer controller that will allow one to be a master and the other one to be a slave. Position information from the master can be used to control the slave. Forces of interaction of the slave with its environment can be reflected back to the motor control of the master to provide a sense of force sensed by the slave. Forces import onto the master by the operator can be fed back into the control of the slave to reduce the forces required to move it.
NASA Astrophysics Data System (ADS)
Krause, H. F.; Deveney, E. F.; Jones, N. L.; Vane, C. R.; Datz, S.; Knudsen, H.; Grafström, P.; Schuch, R.
1997-04-01
Recent atomic physics studies involving ultrarelativistic Pb ions required solid target positioners, scintillators, and a sophisticated data acquisition and control system placed in a remote location at the CERN Super Proton Synchrotron near Geneva, Switzerland. The apparatus, installed in a high-radiation zone underground, had to (i) function for months, (ii) automatically respond to failures such as power outages and particle-induced computer upsets, and (iii) communicate with the outside world via a telephone line. The heart of the apparatus developed was an Apple Macintosh-based CAMAC system that answered the telephone and interpreted and executed remote control commands that (i) sensed and set targets, (ii) controlled voltages and discriminator levels for scintillators, (iii) modified data acquisition hardware logic, (iv) reported control information, and (v) automatically synchronized data acquisition to the CERN spill cycle via a modem signal and transmitted experimental data to a remote computer. No problems were experienced using intercontinental telephone connections at 1200 baud. Our successful "virtual laboratory" approach that uses off-the-shelf electronics is generally adaptable to more conventional bench-type experiments.
The Achilles' heel of left ventricular assist device therapy: right ventricle.
Ranganath, Neel K; Smith, Deane E; Moazami, Nader
2018-06-01
Many patients suffer from either persistent right ventricular failure (RVF) at the time of left ventricular assist device (LVAD) or have ongoing symptoms consistent with RVF during chronic mechanical circulatory support. The lack of long-term right ventricular assist devices (RVADs) has limited the impact that mechanical circulatory support can provide to patients with biventricular failure. We aim to review the entire spectrum of RVF in patients receiving LVADs and reflect on why this entity remains the Achilles' heel of LVAD therapy. In the early postoperative period, LVAD implantation reduces right ventricle (RV) afterload, but RV dysfunction may be exacerbated secondary to increased venous return. With prolonged therapy, the decreased RV afterload leads to improved RV contractile function. Bayesian statistical models outperform previously published preoperative risk scores by considering inter-relationships and conditional probabilities amongst independent variables. Various echocardiographic parameters and the pulmonary artery pulsatility index have shown promise in predicting post-LVAD RVF. Recent publications have delineated the emergence of 'delayed' RVF. Several devices are currently being investigated for use as RVADs. Post-LVAD RVF depends on the RV's ability to adapt to acute hemodynamic changes imposed by the LVAD. Management options are limited due to the lack of an easily implantable, chronic-use RVAD.
Hemodynamic Performance of a Novel Right Ventricular Assist Device (PERKAT).
Kretzschmar, Daniel; Schulze, P Christian; Ferrari, Markus W
Acute right ventricular failure (RVF) is an increasing clinical problem and a life-threatening condition. Right ventricular assist devices represent a reasonable treatment option for patients with refractory RVF. We here present a novel percutaneously implantable device for right ventricular support. The PERKAT device is based on a nitinol stent cage, which is covered with valve-carrying foils. A flexible outlet trunk with a pigtail tip is connected to the distal part. The device is driven by an intra-aortic balloon pump (IABP) drive unit, which inflates/deflates a standard IABP-balloon placed within the stent cage. In-vitro evaluation was done in a liquid bath containing water or blood analog. The PERKAT device was tested in different afterload settings using two different IABP-balloons and varying inflation/deflation rates. We detected flow rates ranging from 1.97 to 3.93 L/min depending on the afterload setting, inflation/deflation rate, balloon size, and the medium used. Flow rates between water and blood analog were nearly comparable, and in the higher inflation/deflation rate settings slightly higher with water. Based on this promising in vitro data, the innovative percutaneously implantable PERKAT device has a potential to become a therapeutic option for patients with RVF refractory to medical treatment.
Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Betterton, Edward; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J
2017-07-01
With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Technique of after-loading interstitial implants.
Syed, A M; Feder, B H
1977-01-01
Interstitial implants are either removable or permanent (and occasionally a combination of both). Permanent implants are generally utilized where tumors are not accessible enough to permit easy removal of sources or where accurate source distribution is less critical. They are useful for cancers of the lung, pancreas, prostate, bladder, lymph nodes, etc. Radon and gold-198 have been largely replaced by iodine-125. Our major interests are in the removable after-loading iridium-192 implant techniques. Template (steel guide) and non-template (plastic tube) techniques are utilized. Templates are preferred where the tumor volume can only be approached from one side and where accurate positioning of sources would otherwise be difficult. They are useful for cancers of the cervix, vagina, urethra, and rectum. Non-template (plastic tube) techniques are preferred where the tumor volume can be approached from at least two sides and where templates are either not feasible or not essential for accurate positioning of sources. The single needle non-template approach is useful for cancers of lip, nodes, and breast (plastic button) and for cancers of the oral cavity and oropharynx (gold button). The paired needle non-template approach is useful for cancers of the gum, retromolar trigone, and base of tongue (loop technique) and for cancers of the palate (arch technique). Procedures for each technique are described in detail.
Physiological Characterization of the SynCardia Total Artificial Heart in a Mock Circulation System
Crosby, Jessica R.; DeCook, Katrina J.; Tran, Phat L.; Smith, Richard G.; Larson, Douglas F.; Khalpey, Zain I.; Burkhoff, Daniel; Slepian, Marvin J.
2014-01-01
The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving bi-ventricular replacement system for a wide variety of patients with end-stage heart failure. While the clinical performance of the TAH is established, modern physiologic characterization, in terms of elastance behavior and pressure-volume characterization has not been defined. Herein we examine the TAH in terms of elastance using a non-ejecting left-ventricle, and then characterize the pressure-volume relationship of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Further, we show that the TAH has a pressure-volume relationship behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload, however this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared to the human heart. PMID:25551416
Physiological characterization of the SynCardia total artificial heart in a mock circulation system.
Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J
2015-01-01
The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving biventricular replacement system for a wide variety of patients with end-stage heart failure. Although the clinical performance of the TAH is established, modern physiological characterization, in terms of elastance behavior and pressure-volume (PV) characterization has not been defined. Herein, we examine the TAH in terms of elastance using a nonejecting left ventricle, and then characterize the PV relation of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Furthermore, we show that the TAH has a PV relation behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload-dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload; however, this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared with the human heart.
Hayashi, Nobuyoshi; Sugawara, Tohru; Shintani, Motoaki; Kato, Shinji
1989-01-01
A versatile automated apparatus, equipped with an artificial intelligence has been developed which may be used to prepare and isolate a wide variety of compounds. The prediction of the optimum reaction conditions and the reaction control in real time, are accomplished using novel kinetic equations and substituent effects in an artificial intelligence software which has already reported [1]. This paper deals with the design and construction of the fully automated system, and its application to the synthesis of a substituted N-(carboxyalkyl)amino acid. The apparatus is composed of units for perfoming various tasks, e.g. reagent supply, reaction, purification and separation, each linked to a control system. All synthetic processes including washing and drying of the apparatus after each synthetic run were automatically performed from the mixing of the reactants to the isolation of the products as powders with purities of greater than 98%. The automated apparatus has been able to run for 24 hours per day, and the average rate of synthesis of substituted N-(carboxyalkyl)amino acids has been three compounds daily. The apparatus is extremely valuable for synthesizing many derivatives of one particular compound structure. Even if the chemical yields are low under the optimum conditions, it is still possible to obtain a sufficient amount of the desired product by repetition of the reaction. Moreover it was possible to greatly reduce the manual involvement of the many syntheses which are a necessary part of pharmaceutical research. PMID:18924679
Flash X-Ray Apparatus With Spectrum Control Functions For Medical Use And Fuji Computed Radiography
NASA Astrophysics Data System (ADS)
Isobe, H.; Sato, E.; Hayasi, Y.; Suzuki, M.; Arima, H.; Hoshino, F.
1985-02-01
Flash radiographic bio-medical studies at sub-microsecond intervals were performed by using both a new type of flash X-ray(FX) apparatus with spectrum control functions and Fuji Computed Radiography(FCR). This single flasher tends to have a comparatively long exposure time and the electric pulse width of the FX wave form is about 0.3,usec. The maximum FX dose is about 50mR at 1m per pulse, and the effective focal spot varies according to condenser charging voltage, A-C distance, etc., ranging from 1.0 to 3.0mm in diameter, but in the low dose rate region it can be reduced to less than 1.0mm in diameter. The FX dose is determined by the condenser charging voltage and the A-C distance, while the FX spectrum is determined by the average voltage of the FX tube and filters. Various clear FX images were obtained by controlling the spectrum and dose. FCR is a new storage medium for medical radiography developed by the Fuji Photo Film Co., Ltd. and this apparatus has various image forming functions: low dose radiography, film density control, image contrast control, subtraction management and others. We have used this new apparatus in conjunction with our FX radiography and have obtained some new and interesting biomedical radiograms: the edge enhancement image, the instantaneous enlarged image, and the single exposure energy subtraction image using the FX spectrum distribution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallegos-Lopez, Gabriel; Perisic, Milun; Kinoshita, Michael H.
2017-03-14
Embodiments of the present invention relate to methods, systems and apparatus for controlling operation of a multi-phase machine in a motor drive system. The disclosed embodiments provide a mechanism for adjusting modulation index of voltage commands to improve linearity of the voltage commands.
Davalos, Rafael V [Oakland, CA; Ellis, Christopher R. B. [Oakland, CA
2008-03-04
Disclosed is an apparatus and method for inserting one or several chemical or biological species into phospholipid containers that are controlled within a microfluidic network, wherein individual containers are tracked and manipulated by electric fields and wherein the contained species may be chemically processed.
The overall objective was to provide a dynamic test apparatus that can produce known, controlled high frequency dynamics for the evaluation of current meters and other marine instrumentation. Of primary interest is the establishment of flow sensor measurement capabilities, and he...
Robinet, McLouis
1977-05-31
An apparatus is provided for controlling the activation of a high energy radiation source having a shutter. The apparatus includes magnets and magnetically responsive switches appropriately placed and interconnected so that only with the shutter and other parts of the source in proper position can safe emission of radiation out an open shutter occur.
The Maiden Voyage of a Kinematics Robot
ERIC Educational Resources Information Center
Greenwolfe, Matthew L.
2015-01-01
In a Montessori preschool classroom, students work independently on tasks that absorb their attention in part because the apparatus are carefully designed to make mistakes directly observable and limit exploration to one aspect or dimension. Control of error inheres in the apparatus itself, so that teacher intervention can be minimal. Inspired by…
X- And y-axis driver for rotating microspheres
Weinstein, Berthold W.
1979-01-01
Apparatus for precise control of the motion and position of microspheres for examination of their interior and/or exterior. The apparatus includes an x- and y-axis driver mechanism controlled, for example, by a minicomputer for selectively rotating microspheres retained between a pair of manipulator arms having flat, smooth end surfaces. The driver mechanism includes an apertured plate and ball arrangement which provided for coupled equal and opposite movement of the manipulator arms in two perpendicular directions.
Method and apparatus for adaptive force and position control of manipulators
NASA Technical Reports Server (NTRS)
Seraji, Homayoun (Inventor)
1989-01-01
The present invention discloses systematic methods and apparatus for the design of real time controllers. Real-time control employs adaptive force/position by use of feedforward and feedback controllers, with the feedforward controller being the inverse of the linearized model of robot dynamics and containing only proportional-double-derivative terms is disclosed. The feedback controller, of the proportional-integral-derivative type, ensures that manipulator joints follow reference trajectories and the feedback controller achieves robust tracking of step-plus-exponential trajectories, all in real time. The adaptive controller includes adaptive force and position control within a hybrid control architecture. The adaptive controller, for force control, achieves tracking of desired force setpoints, and the adaptive position controller accomplishes tracking of desired position trajectories. Circuits in the adaptive feedback and feedforward controllers are varied by adaptation laws.
Methods and Devices for Micro-Isolation, Extraction, and/or Analysis of Microscale Components
NASA Technical Reports Server (NTRS)
Wade, Lawrence A. (Inventor); Kartalov, Emil P. (Inventor); Taylor, Clive (Inventor); Shibata, Darryl (Inventor)
2014-01-01
Provided herein are devices and methods for the micro-isolation of biological cellular material. A micro-isolation apparatus described can comprise a photomask that protects regions of interest against DNA-destroying illumination. The micro-isolation apparatus can further comprise photosensitive material defining access wells following illumination and subsequent developing of the photosensitive material. The micro-isolation apparatus can further comprise a chambered microfluidic device comprising channels providing access to wells defined in photosensitive material. The micro-isolation apparatus can comprise a chambered microfluidic device without access wells defined in photosensitive material where valves control the flow of gases or liquids through the channels of the microfluidic device. Also included are methods for selectively isolating cellular material using the apparatuses described herein, as are methods for biochemical analysis of individual regions of interest of cellular material using the devices described herein. Further included are methods of making masking arrays useful for the methods described herein.
Method and apparatus for deflection measurements using eddy current effects
NASA Astrophysics Data System (ADS)
Chern, Engmin J.
1993-05-01
A method and apparatus for inserting and moving a sensing assembly with a mechanical positioning assembly to a desired remote location of a surface of a specimen under test and measuring angle and/or deflection by sensing the change in the impedance of at least one sensor coil located in a base plate which has a rotatable conductive plate pivotally mounted thereon so as to uncover the sensor coil(s) whose impedance changes as a function of deflection away from the center line of the base plate in response to the movement of the rotator plate when contacting the surface of the specimen under test is presented. The apparatus includes the combination of a system controller, a sensing assembly, an eddy current impedance measuring apparatus, and a mechanical positioning assembly driven by the impedance measuring apparatus to position the sensing assembly at a desired location of the specimen.
Method and apparatus for deflection measurements using eddy current effects
NASA Technical Reports Server (NTRS)
Chern, Engmin J. (Inventor)
1993-01-01
A method and apparatus for inserting and moving a sensing assembly with a mechanical positioning assembly to a desired remote location of a surface of a specimen under test and measuring angle and/or deflection by sensing the change in the impedance of at least one sensor coil located in a base plate which has a rotatable conductive plate pivotally mounted thereon so as to uncover the sensor coil(s) whose impedance changes as a function of deflection away from the center line of the base plate in response to the movement of the rotator plate when contacting the surface of the specimen under test is presented. The apparatus includes the combination of a system controller, a sensing assembly, an eddy current impedance measuring apparatus, and a mechanical positioning assembly driven by the impedance measuring apparatus to position the sensing assembly at a desired location of the specimen.
Repeated furrow formation from a single mitotic apparatus in cylindrical sand dollar eggs.
Rappaport, R
1985-04-01
The methods used previously to demonstrate the ability of a single mitotic apparatus to elicit multiple furrows involved considerable cell distortion and did not permit the investigator to control the positioning of the parts or to observe satisfactorily the early stages of furrow development. In this investigation, Echinarachnius parma eggs were confined in 82 microns i.d. transparent, silicone rubber-walled capillaries, and the mitotic apparatus was moved by pushing the poles inward with 55-microns-diameter glass balls. When the mitotic apparatus was shifted immediately after the furrow first appeared, a new furrow appeared in the normal relation to the new position in 1-2 minutes. The same mitotic apparatus could elicit up to 13 furrows as it was shifted back and forth by alternately pushing in the poles. The previous furrow regressed as the new furrow developed. The operations protracted the furrow establishment period to as long as 24.5 minutes after establishment of the first furrow. The characteristics of furrow regression were related to the distance the mitotic apparatus was moved. It is unlikely that regression was caused either by stress imposed on the surface or the removal of the mitotic apparatus from the vicinity of the furrow.
Thermomagnetic burn control for magnetic fusion reactor
Rawls, J.M.; Peuron, A.U.
1980-07-01
Apparatus is provided for controlling the plasma energy production rate of a magnetic-confinement fusion reactor, by controlling the magnetic field ripple. The apparatus includes a group of shield sectors formed of ferromagnetic material which has a temperature-dependent saturation magnetization, with each shield lying between the plasma and a toroidal field coil. A mechanism for controlling the temperature of the magnetic shields, as by controlling the flow of cooling water therethrough, thereby controls the saturation magnetization of the shields and therefore the amount of ripple in the magnetic field that confines the plasma, to thereby control the amount of heat loss from the plasma. This heat loss in turn determines the plasma state and thus the rate of energy production.
Edge coating apparatus with movable roller applicator for solar cell substrates
Pavani, Luca; Abas, Emmanuel
2012-12-04
A non-contact edge coating apparatus includes an applicator for applying a coating material on an edge of a solar cell substrate and a control system configured to drive the applicator. The control system may drive the applicator along an axis to maintain a distance with an edge of the substrate as the substrate is rotated to have the edge coated with a coating material. The applicator may include a recessed portion into which the edge of the substrate is received for edge coating. For example, the applicator may be a roller with a groove. Coating material may be introduced into the groove for application onto the edge of the substrate. A variety of coating materials may be employed with the apparatus including hot melt ink and UV curable plating resist.
Apparatus and method for magnetically unloading a rotor bearing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanders, Seth Robert
An apparatus and method for unloading a rotor bearing is described. The apparatus includes an electromagnet for levitating the rotor. In one embodiment, a sensor of the magnetic field near the electromagnet is used to control the current to levitate the rotor. In another embodiment, a method is provided that includes rotating the rotor, increasing the current to levitate the rotor and decrease the gap between electromagnet and rotor, and then reducing the current to levitate the rotor with a minimal amount of electric power to the electromagnet.
Selective flow path alpha particle detector and method of use
Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore
2002-01-01
A method and apparatus for monitoring alpha contamination are provided in which ions generated in the air surrounding the item, by the passage of alpha particles, are moved to a distant detector location. The parts of the item from which ions are withdrawn can be controlled by restricting the air flow over different portions of the apparatus. In this way, detection of internal and external surfaces separately, for instance, can be provided. The apparatus and method are particularly suited for use in undertaking alpha contamination measurements during the commissioning operations.
Electroplating method and apparatus
Looney, Robert B.; Smith, William E. L.
1978-06-20
An apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm.
Continuous air monitor filter changeout apparatus
Rodgers, John C [Santa Fe, NM
2008-07-15
An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.
Stam, Kelly; van Duin, Richard W B; Uitterdijk, André; Cai, Zongye; Duncker, Dirk J; Merkus, Daphne
2018-03-01
Chronic thromboembolic pulmonary hypertension (CTEPH) develops in 4% of patients after pulmonary embolism and is accompanied by an impaired exercise tolerance, which is ascribed to the increased right ventricular (RV) afterload in combination with a ventilation/perfusion (V/Q) mismatch in the lungs. The present study aimed to investigate changes in arterial Po 2 and hemodynamics in response to graded treadmill exercise during development and progression of CTEPH in a novel swine model. Swine were chronically instrumented and received multiple pulmonary embolisms by 1) microsphere infusion (Spheres) over 5 wk, 2) endothelial dysfunction by administration of the endothelial nitric oxide synthase inhibitor N ω -nitro-l-arginine methyl ester (L-NAME) for 7 wk, 3) combined pulmonary embolisms and endothelial dysfunction (L-NAME + Spheres), or 4) served as sham-operated controls (sham). After a 9 wk followup, embolization combined with endothelial dysfunction resulted in CTEPH, as evidenced by mean pulmonary artery pressures of 39.5 ± 5.1 vs. 19.1 ± 1.5 mmHg (Spheres, P < 0.001), 22.7 ± 2.0 mmHg (L-NAME, P < 0.001), and 20.1 ± 1.5 mmHg (sham, P < 0.001), and a decrease in arterial Po 2 that was exacerbated during exercise, indicating V/Q mismatch. RV dysfunction was present after 5 wk of embolization, both at rest (trend toward increased RV end-systolic lumen area, P = 0.085, and decreased stroke volume index, P = 0.042) and during exercise (decreased stroke volume index vs. control, P = 0.040). With sustained pulmonary hypertension, RV hypertrophy (Fulton index P = 0.022) improved RV function at rest and during exercise, but this improvement was insufficient in CTEPH swine to result in an exercise-induced increase in cardiac index. In conclusion, embolization in combination with endothelial dysfunction results in CTEPH in swine. Exercise increased RV afterload, exacerbated the V/Q mismatch, and unmasked RV dysfunction. NEW & NOTEWORTHY Here, we present the first double-hit chronic thromboembolic pulmonary hypertension swine model. We show that embolization as well as endothelial dysfunction is required to induce sustained pulmonary hypertension, which is accompanied by altered exercise hemodynamics and an exacerbated ventilation/perfusion mismatch during exercise.
Zierer, Andreas; Voeller, Rochus K.; Melby, Spencer J.; Steendijk, Paul; Moon, Marc R.
2009-01-01
Purpose Patients with chronic pulmonary hypertension (CPH) who demonstrate a pulmonary vasodilation following calcium channel blocker (CCB) administration are defined as “responders”. In contrast, “non-responders” are patients who do not show such a pulmonary vasodilation with CCB therapy. The purpose of this investigation was to study the effects of CCB therapy on right heart mechanics in experimental CCB responders versus CCB non-responders. Methods In 12 dogs, right atrial (RA) and ventricular (RV) pressure and volume (conductance catheters) were simultaneously recorded after 3 months of progressive pulmonary artery (PA) banding. Diltiazem was given at 10 mg/hr with the PA constricted (simulated CCB non-responder). Responders were then created by releasing the PA band to unload the ventricle. RA and RV contractility and diastolic stiffness (slope of end-systolic and end-diastolic pressure-volume relations) were calculated and RA reservoir and conduit function were quantified as RA inflow with the tricuspid valve closed versus open, respectively. Results With CCB, RA contractility (p<0.03) and cardiac output (p<0.004) were compromised in simulated non-responders while RA stroke work was pharmacologically depressed in the setting of an unchanged afterload. After simulating a responder by controlled PA band release, the RA became less distensible, causing a shift from reservoir to conduit function (p<0.001) towards physiologic baseline conditions and a recovery in the hyperdynamic compensatory response in both chambers (p<0.007) as evidenced in a declined RA and RV contractility with an improved cardiac output as compared to CPH and simulated non-responders. RA and RV diastolic function in both groups was not affected by CCB. Conclusions CCB did not impact RV function in simulated non-responders, but significantly impaired RA contractility and cardiac output. In simulated responders, afterload fell substantially, thereby allowing the RA and RV to recover from their pathological hyperdynamic contractile response to CPH. This affect was able to outweigh the intrinsic negative effects of CCB therapy on systolic RA function. Current data suggest that the RA in CPH is much more sensitive to CCB therapy than the RV and delineate for the first time why CCB therapy in CPH has been empirically restricted to documented responders. PMID:19237986
Wireless power charging using point of load controlled high frequency power converters
Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.
2015-10-13
An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.
Method and Apparatus for Improved Spatial Light Modulation
NASA Technical Reports Server (NTRS)
Soutar, Colin (Inventor); Juday, Richard D. (Inventor)
2000-01-01
A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain the optical processing objective.
Method and Apparatus for Improved Spatial Light Modulation
NASA Technical Reports Server (NTRS)
Colin, Soutar (Inventor); Juday, Richard D. (Inventor)
1999-01-01
A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain die optical processing objective.
A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler
NASA Astrophysics Data System (ADS)
Chen, L. B.; Liu, S. X.; Gu, K. X.; Zhou, Y.; Wang, J. J.
2015-12-01
This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper.
Polarization Imaging Apparatus
NASA Technical Reports Server (NTRS)
Zou, Yingyin K.; Chen, Qiushui
2010-01-01
A polarization imaging apparatus has shown promise as a prototype of instruments for medical imaging with contrast greater than that achievable by use of non-polarized light. The underlying principles of design and operation are derived from observations that light interacts with tissue ultrastructures that affect reflectance, scattering, absorption, and polarization of light. The apparatus utilizes high-speed electro-optical components for generating light properties and acquiring polarization images through aligned polarizers. These components include phase retarders made of OptoCeramic (registered TradeMark) material - a ceramic that has a high electro-optical coefficient. The apparatus includes a computer running a program that implements a novel algorithm for controlling the phase retarders, capturing image data, and computing the Stokes polarization images. Potential applications include imaging of superficial cancers and other skin lesions, early detection of diseased cells, and microscopic analysis of tissues. The high imaging speed of this apparatus could be beneficial for observing live cells or tissues, and could enable rapid identification of moving targets in astronomy and national defense. The apparatus could also be used as an analysis tool in material research and industrial processing.
Liu, F; Chen, D; Liao, Y; Diao, L; Liu, Y; Wu, M; Xue, X; You, C; Kang, Y
2012-01-01
To investigate the effect of the Intrafix(®) SafeSet infusion apparatus on the incidence of phlebitis in patients being intravenously infused in a neurological intensive care unit (ICU). Patients aged > 12 years, with no history of diabetes mellitus and no existing phlebitis, requiring a daily peripheral intravenous infusion of ≥ 8 h with the total period lasting ≥ 3 days, were enrolled. Infusions were performed using the Intrafix(®) SafeSet or normal infusion apparatus. Incidence of phlebitis (scored according to the Infusion Nursing Standards of Practice of the American Infusion Nurses Society) was analysed. Patients (n = 1545) were allocated to Intrafix(®) SafeSet (n = 709) or normal infusion (n = 836) groups, matched for age, gender and preliminary diagnosis. Incidence of phlebitis was significantly higher using normal infusion apparatus compared with the Intrafix(®) SafeSet (23.4% versus 17.9%, respectively). Intrafix(®) SafeSet infusion apparatus significantly reduced the incidence of phlebitis in patients in the neurological ICU, compared with normal infusion apparatus, and may be suitable for use in routine clinical practice.
In-situ control system for atomization
Anderson, I.E.; Figliola, R.S.; Terpstra, R.L.
1995-06-13
Melt atomizing apparatus comprising a melt supply orifice for supplying the melt for atomization and gas supply orifices proximate the melt supply orifice for supplying atomizing gas to atomize the melt as an atomization spray is disclosed. The apparatus includes a sensor, such as an optical and/or audio sensor, for providing atomization spray data, and a control unit responsive to the sensed atomization spray data for controlling at least one of the atomizing gas pressure and an actuator to adjust the relative position of the gas supply orifice and melt supply in a manner to achieve a desired atomization spray. 3 figs.
In-situ control system for atomization
Anderson, Iver E.; Figliola, Richard S.; Terpstra, Robert L.
1995-06-13
Melt atomizing apparatus comprising a melt supply orifice for supplying the melt for atomization and gas supply orifices proximate the melt supply orifice for supplying atomizing gas to atomize the melt as an atomization spray. The apparatus includes a sensor, such as an optical and/or audio sensor, for providing atomization spray data, and a control unit responsive to the sensed atomization spray data for controlling at least one of the atomizing gas pressure and an actuator to adjust the relative position of the gas supply orifice and melt supply in a manner to achieve a desired atomization spray.
Seat cushion to provide realistic acceleration cues to aircraft simulator pilot
NASA Technical Reports Server (NTRS)
Ashworth, B. R. (Inventor)
1979-01-01
Seat cushions, each including an air cell with a non-compressible surface, are disclosed. The apparatus are provided for initially controlling the air pressure in the air cells to allow the two main support areas of the simulator pilot to touch the non-compressible surface and thus begin to compress the flesh near these areas. During a simulated flight the apparatus control the air pressure in the cells to simulate the events that occur in a seat cushion during actual flight.
Solder dross removal apparatus
NASA Technical Reports Server (NTRS)
Webb, Winston S. (Inventor)
1990-01-01
An automatic dross removal apparatus is disclosed for removing dross from the surface of a solder bath in an automated electric component handling system. A rotatable wiper blade is positioned adjacent the solder bath which skims the dross off of the surface prior to the dipping of a robot conveyed component into the bath. An electronic control circuit causes a motor to rotate the wiper arm one full rotational cycle each time a pulse is received from a robot controller as a component approaches the solder bath.
Methods, systems and apparatus for synchronous current regulation of a five-phase machine
Gallegos-Lopez, Gabriel; Perisic, Milun
2012-10-09
Methods, systems and apparatus are provided for controlling operation of and regulating current provided to a five-phase machine when one or more phases has experienced a fault or has failed. In one implementation, the disclosed embodiments can be used to synchronously regulate current in a vector controlled motor drive system that includes a five-phase AC machine, a five-phase inverter module coupled to the five-phase AC machine, and a synchronous current regulator.
Automatic grinding apparatus to control uniform specimen thicknesses
Bryner, Joseph S.
1982-01-01
This invention is directed to a new and improved grinding apparatus comprising (1) a movable grinding surface, (2) a specimen holder, (3) a displacing device for moving the holder and/or grinding surface toward one another, and (4) at least three devices for limiting displacement of the holder to the grinding surface.
Automatic grinding apparatus to control uniform specimen thicknesses
Bryner, J.S.
1981-01-07
This invention is directed to a new and improved grinding apparatus comprisng: (1) a movable grinding surface; (2) a specimen holder; (3) a dislacing means for moving the holder and/or grinding surface toward one another; and (4) at least three means for limiting displacement of the holder to the grinding surface.
He, Jia-xi; Zhou, Wei; Qiu, Hai-li; Yang, Guang-tao
2013-12-01
To investigate the non-ionizing radiation hazards from physiotherapy equipment in medical institutions and to explore feasible control measures for occupational diseases. On-site measurement and assessment of ultra-high-frequency radiation, high-frequency electromagnetic field, microwave radiation, and laser radiation were carried out in 16 medical institutions using the methods in the Measurement of Physical Agents in Workplace (GBZ/T189-2007). All the investigated medical institutions failed to take effective protective measures against non-ionizing radiation. Of the 17 ultra-short wave therapy apparatus, 70.6%, 47.1%, and 17.64% had a safe intensity of ultra-high-frequency radiation on the head, chest, and abdomen, respectively. Of the 4 external high-frequency thermotherapy apparatus, 100%, 75%, and 75%had a safe intensity of high-frequency electromagnetic field on the head, chest, and abdomen, respectively. In addition, the intensities of microwave radiation and laser radiation produced by the 18 microwave therapy apparatus and 12 laser therapeutic apparatus met national health standards. There are non-ionizing radiation hazards from physiotherapy equipment in medical institutions, and effective prevention and control measures are necessary.
Method and apparatus for reducing cold-phase emissions by utilizing oxygen-enriched intake air
Poola, Ramesh B.; Sekar, Ramanujam R.; Stork, Kevin C.
1997-01-01
An oxygen-enriched air intake control system for an internal combustion engine includes air directing apparatus to control the air flow into the intake of the engine. During normal operation of the engine, ambient air flowing from an air filter of the engine flows through the air directing apparatus into the intake of the engine. In order to decrease the amount of carbon monoxide (CO) and hydrocarbon (HC) emissions that tend to be produced by the engine during a short period of time after the engine is started, the air directing apparatus diverts for a short period of time following the start up of the engine at least a portion of the ambient air from the air filter through a secondary path. The secondary path includes a selectively permeable membrane through which the diverted portion of the ambient air flows. The selectively permeable membrane separates nitrogen and oxygen from the diverted air so that oxygen enriched air containing from about 23% to 25% oxygen by volume is supplied to the intake of the engine.
NASA Technical Reports Server (NTRS)
Olson, S. L.; Beeson, H.; Haas, J.
2001-01-01
One of the performance goals for NASA's enterprise of Human Exploration and Development of Space (HEDS) is to develop methods, data bases, and validating tests for material flammability characterization, hazard reduction, and fire detection/suppression strategies for spacecraft and extraterrestrial habitats. This work addresses these needs by applying the fundamental knowledge gained from low stretch experiments to the development of a normal gravity low stretch material flammability test method. The concept of the apparatus being developed uses the low stretch geometry to simulate the conditions of the extraterrestrial environment through proper scaling of the sample dimensions to reduce the buoyant stretch in normal gravity. The apparatus uses controlled forced-air flow to augment the low stretch to levels which simulate Lunar or Martian gravity levels. In addition, the effect of imposed radiant heat flux on material flammability can be studied with the cone heater. After breadboard testing, the apparatus will be integrated into NASA's White Sands Test Facility's Atmosphere-Controlled Cone Calorimeter for evaluation as a new materials screening test method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiuchi, T.; Sakurai, H.
1988-09-20
This patent describes an apparatus for controlling the solenoid current of a solenoid valve which controls suction air in an internal combustion engine. The apparatus consists of: (a) engine rotational speed detector means for detecting engine rotational speed; (b) aimed idle speed setting means for generating a signal corresponding to a predetermined idling speed; (c) first calculating means coupled to the engine rotational speed detector means and the aimed idle speed setting means for calculating a feedback control term (Ifb(n)) as a function of an integration term (Iai), a proportion term (Ip), and a differentiation term (Id); (d) first determiningmore » and storing means coupled to the first calculating means, for determining an integration term (Iai(n)) of the the feedback control term (Ifb(n)) and for determining a determined value (Ixref) in accordance therewith; (e) changeover means coupled to the first calculating means and the first determining and storing means for selecting the output of one of the first calculating means or the first determining and storing means; (f) first signal generating means coupled to the changeover means for generating a solenoid current control value (Icmd) as a function of the output of the changeover means.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiuchi, T.; Yasuoka, A.
1988-09-13
This patent describes apparatus for controlling the solenoid current of a selenoid valve which controls the amount of suction air in an internal combustion engine, the apparatus comprising: (a) engine rotational speed detector means for detecting engine rotational speed; (b) aimed idle speed setting means for generating a signal corresponding to a predetermined idling speed; (c) first calculating means coupled to the engine rotational speed detector means and the aimed idle speed setting means for calculating a feedback control term Ifb(n) as a function of an integration term (Iai), a proportion term (Ip), and a differentiation term (Id); (d) firstmore » determining and storing means coupled to the first calculating means, for determining an integration term (Iai(n)) of the feedback control term (Ifb(n)) and for determining a determined value (Ixref) in accordance therewith; (e) changeover means coupled to the first calculating means and the first determining and storing means for selecting the output of one of the first calculating means or the first determining and storing means; (f) first signal generating means coupled to the changeover means for generating a solenoid current control value (Icmd) as a function of the output of the changeover.« less
Thermomagnetic burn control for magnetic fusion reactor
Rawls, John M.; Peuron, Unto A.
1982-01-01
Apparatus is provided for controlling the plasma energy production rate of a magnetic-confinement fusion reactor, by controlling the magnetic field ripple. The apparatus includes a group of shield sectors (30a, 30b, etc.) formed of ferromagnetic material which has a temperature-dependent saturation magnetization, with each shield lying between the plasma (12) and a toroidal field coil (18). A mechanism (60) for controlling the temperature of the magnetic shields, as by controlling the flow of cooling water therethrough, thereby controls the saturation magnetization of the shields and therefore the amount of ripple in the magnetic field that confines the plasma, to thereby control the amount of heat loss from the plasma. This heat loss in turn determines the plasma state and thus the rate of energy production.
Dynamically controlled crystallization method and apparatus and crystals obtained thereby
NASA Technical Reports Server (NTRS)
Arnowitz, Leonard (Inventor); Steinberg, Emanuel (Inventor)
2003-01-01
A method and apparatus for dynamically controlling the crystallization of molecules including a crystallization chamber (14) or chambers for holding molecules in a precipitant solution, one or more precipitant solution reservoirs (16, 18), communication passages (17, 19) respectively coupling the crystallization chamber(s) with each of the precipitant solution reservoirs, and transfer mechanisms (20, 21, 22, 24, 26, 28) configured to respectively transfer precipitant solution between each of the precipitant solution reservoirs and the crystallization chamber(s). The transfer mechanisms are interlocked to maintain a constant volume of precipitant solution in the crystallization chamber(s). Precipitant solutions of different concentrations are transferred into and out of the crystallization chamber(s) to adjust the concentration of precipitant in the crystallization chamber(s) to achieve precise control of the crystallization process. The method and apparatus can be used effectively to grow crystals under reduced gravity conditions such as microgravity conditions of space, and under conditions of reduced or enhanced effective gravity as induced by a powerful magnetic field.
Apparatus For Etching Or Depositing A Desired Profile Onto A Surface
Rushford, Michael C.; Britten, Jerald A.
2004-05-25
An apparatus and method for modifying the surface of an object by contacting said surface with a liquid processing solution using the liquid applicator geometry and Marangoni effect (surface tension gradient-driven flow) to define and confine the dimensions of the wetted zone on said object surface. In particular, the method and apparatus involve contouring or figuring the surface of an object using an etchant solution as the wetting fluid and using real-time metrology (e.g. interferometry) to control the placement and dwell time of this wetted zone locally on the surface of said object, thereby removing material from the surface of the object in a controlled manner. One demonstrated manifestation is in the deterministic optical figuring of thin glasses by wet chemical etching using a buffered hydrofluoric acid solution and Marangoni effect.
Dual side control for inductive power transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Hunter; Sealy, Kylee; Gilchrist, Aaron
An apparatus for dual side control includes a measurement module that measures a voltage and a current of an IPT system. The voltage includes an output voltage and/or an input voltage and the current includes an output current and/or an input current. The output voltage and the output current are measured at an output of the IPT system and the input voltage and the input current measured at an input of the IPT system. The apparatus includes a max efficiency module that determines a maximum efficiency for the IPT system. The max efficiency module uses parameters of the IPT systemmore » to iterate to a maximum efficiency. The apparatus includes an adjustment module that adjusts one or more parameters in the IPT system consistent with the maximum efficiency calculated by the max efficiency module.« less
Computer implemented method, and apparatus for controlling a hand-held tool
NASA Technical Reports Server (NTRS)
Wagner, Kenneth William (Inventor); Taylor, James Clayton (Inventor)
1999-01-01
The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.
System for throttling and compensation for variable feedstock properties
Meyer, J. W.
1981-05-05
Apparatus is shown for adjusting the feed rate of pulverized feed material into a pressurized container. The apparatus also has utility for compensating for variations in the permeability of the feed material. A rotor that includes sprues with provision for controlling the pressure distribution along the sprues is located within the pressurized container. The rotor hub is connected to a drive means and a material supply means which extend through the wall of the container. A line for controlling pressure along the sprues by gas injection is connected to a chamber between sections of the sprue for controlling gas pressure at that point. The gas pressure control line is connected to a pressurized gas source and a control system external to the rotor. 10 figs.
System for throttling and compensation for variable feedstock properties
Meyer, John W.
1981-01-01
Apparatus is shown for adjusting the feed rate of pulverized feed material into a pressurized container. The apparatus also has utility for compensating for variations in the permeability of the feed material. A rotor that includes sprues with provision for controlling the pressure distribution along the sprues is located within the pressurized container. The rotor hub is connected to a drive means and a material supply means which extend through the wall of the container. A line for controlling pressure along the sprues by gas injection is connected to a chamber between sections of the sprue for controlling gas pressure at that point. The gas pressure control line is connected to a pressurized gas source and a control system external to the rotor.
Method and apparatus for controlling fluid flow
Miller, J.R.
1980-06-27
A method and apparatus for precisely controlling the rate (and hence amount) of fluid flow are given. The controlled flow rate is finely adjustable, can be extremely small (on the order of microliter-atmospheres per second), can be adjusted to zero (flow stopped), and is stable to better than 1% with time. The dead volume of the valve can be made arbitrarily small, in fact essentially zero. The valve employs no wearing mechanical parts (including springs, stems, or seals). The valve is finely adjustable, has a flow rate dynamic range of many decades, can be made compatible with any fluid, and is suitable for incorporation into an open or closed loop servo-control system.
Apparatus for electrode current control in linear MHD generators
Demirjian, Ara M.; Solbes, Albert
1984-01-01
Apparatus for controlling a plurality of opposing, electrode, direct-currents at pre-set locations across a channel that comprises a converter for converting each electrode current into first and second periodic control signals which are 180.degree. out of phase with respect to each other and which have equal magnitudes corresponding to the magnitude of the associated electrode current; and couplers for magnetically coupling individual ones of the first control signals and for magnetically coupling individual ones of the second signals such that the corresponding electrode currents are equalized or rendered proportional by balancing the same in the same or constant ratios in accordance with the locations of the electrode currents.
NASA Technical Reports Server (NTRS)
Kacprowski, J.; Motylewski, J.; Miazga, J.
1974-01-01
An objective method and apparatus for noise control and acoustic diagnostics of motorcar engines are reported. The method and apparatus let us know whether the noisiness of the vehicle under test exceeds the admissible threshold levels given by appropriate standards and if so what is the main source of the excessive noise. The method consists in measuring both the overall noise level and the sound pressure levels in definite frequency bands while the engine speed is controlled as well and may be fixed at prescribed values. Whenever the individually adjusted threshold level has been exceeded in any frequency band, a self-sustaining control signal is sent.
Control system for thermoelectric refrigerator
NASA Technical Reports Server (NTRS)
Nelson, John L. (Inventor); Criscuolo, Lance (Inventor); Gilley, Michael D. (Inventor); Park, Brian V. (Inventor)
1996-01-01
Apparatus including a power supply (202) and control system is provided for maintaining the temperature within an enclosed structure (40) using thermoelectric devices (92). The apparatus may be particularly beneficial for use with a refrigerator (20) having superinsulation materials (46) and phase change materials (112) which cooperate with the thermoelectric device (92) to substantially enhance the overall operating efficiency of the refrigerator (20). The electrical power supply (202) and control system allows increasing the maximum power capability of the thermoelectric device (92) in response to increased heat loads within the refrigerator (20). The electrical power supply (202) and control system may also be used to monitor the performance of the cooling system (70) associated with the refrigerator (20).
Femtosecond Chirp-Free Transient Absorption Method And Apparatus
McBranch, Duncan W.; Klimov, Victor I.
2001-02-20
A method and apparatus for femtosecond transient absorption comprising phase-sensitive detection, spectral scanning and simultaneous controlling of a translation stage to obtain TA spectra information having at least a sensitivity two orders of magnitude higher than that for single-shot methods, with direct, simultaneous compensation for chirp as the data is acquired. The present invention includes a amplified delay translation stage which generates a splittable frequency-doubled laser signal at a predetermined frequency f, a controllable means for synchronously modulating one of the laser signals at a repetition rate of f/2, applying the laser signals to a material to be sample, and acquiring data from the excited sample while simultaneously controlling the controllable means for synchronously modulating.
NASA Technical Reports Server (NTRS)
Childs, Dara; Hale, Keith
1994-01-01
A facility and apparatus are described which determine stiffness, damping, and added-mass rotordynamic coefficients plus steady-state operating characteristics of high speed hydrostatic journal bearings. The apparatus has a current top speed of 29,800 rpm with a bearing diameter of 7.62 cm (3 in.). Purified warm water, 55 C (130 F), is used as a test fluid to achieve elevated Reynolds numbers during operation. The test-fluid pump yields a bearing maximum inlet pressure of 6.9 Mpa (1000 psi). Static load on the bearing is independently controlled and measured. Orthogonally mounted external shakers are used to excite the test stator in the direction of, and perpendicular to, the static load. The apparatus can independently calculate all rotordynamic coefficients at a given operating condition.
Micklash. II, Kenneth James; Dutton, Justin James; Kaye, Steven
2014-06-03
An apparatus for testing of multiple material samples includes a gas delivery control system operatively connectable to the multiple material samples and configured to provide gas to the multiple material samples. Both a gas composition measurement device and pressure measurement devices are included in the apparatus. The apparatus includes multiple selectively openable and closable valves and a series of conduits configured to selectively connect the multiple material samples individually to the gas composition device and the pressure measurement devices by operation of the valves. A mixing system is selectively connectable to the series of conduits and is operable to cause forced mixing of the gas within the series of conduits to achieve a predetermined uniformity of gas composition within the series of conduits and passages.
Spletzer, Barry L.; Fischer, Gary J.; Martinez, Michael A.
2001-01-01
An apparatus that can return a payload to a known orientation after unknown motion, without requiring external power or complex mechanical systems. The apparatus comprises a faceted cage that causes the system to rest in a stable position and orientation after arbitrary motion. A gimbal is mounted with the faceted cage and holds the payload, allowing the payload to move relative to the stable faceted cage. The payload is thereby placed in a known orientation by the interaction of gravity with the geometry of the faceted cage, the mass of the system, and the motion of the payload and gimbal. No additional energy, control, or mechanical actuation is required. The apparatus is suitable for use in applications requiring positioning of a payload to a known orientation after arbitrary or uncontrolled motion, including remote sensing and mobile robot applications.
Phase change material thermal capacitor clothing
NASA Technical Reports Server (NTRS)
Buckley, Theresa M. (Inventor)
2005-01-01
An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.
Apparatus and method for evaporator defrosting
Mei, Viung C.; Chen, Fang C.; Domitrovic, Ronald E.
2001-01-01
An apparatus and method for warm-liquid defrosting of the evaporator of a refrigeration system. The apparatus includes a first refrigerant expansion device that selectively expands refrigerant for cooling the evaporator, a second refrigerant expansion device that selectively expands the refrigerant after the refrigerant has passed through the evaporator, and a defrosting control for the first refrigerant expansion device and second refrigerant expansion device to selectively defrost the evaporator by causing warm refrigerant to flow through the evaporator. The apparatus is alternately embodied with a first refrigerant bypass and/or a second refrigerant bypass for selectively directing refrigerant to respectively bypass the first refrigerant expansion device and the second refrigerant expansion device, and with the defrosting control connected to the first refrigerant bypass and/or the second refrigerant bypass to selectively activate and deactivate the bypasses depending upon the current cycle of the refrigeration system. The apparatus alternately includes an accumulator for accumulating liquid and/or gaseous refrigerant that is then pumped either to a refrigerant receiver or the first refrigerant expansion device for enhanced evaporator defrosting capability. The inventive method of defrosting an evaporator in a refrigeration system includes the steps of compressing refrigerant in a compressor and cooling the refrigerant in the condenser such that the refrigerant is substantially in liquid form, passing the refrigerant substantially in liquid form through the evaporator, and expanding the refrigerant with a refrigerant expansion device after the refrigerant substantially passes through the evaporator.
Method and apparatus for thermal power generation
Mangus, James D.
1979-01-01
A method and apparatus for power generation from a recirculating superheat-reheat circuit with multiple expansion stages which alleviates complex control systems and minimizes thermal cycling of system components, particularly the reheater. The invention includes preheating cold reheat fluid from the first expansion stage prior to its entering the reheater with fluid from the evaporator or drum component.
21 CFR 864.9225 - Cell-freezing apparatus and reagents for in vitro diagnostic use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... use are devices used to freeze human red blood cells for in vitro diagnostic use. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E... Establishments That Manufacture Blood and Blood Products § 864.9225 Cell-freezing apparatus and reagents for in...
21 CFR 864.9225 - Cell-freezing apparatus and reagents for in vitro diagnostic use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... use are devices used to freeze human red blood cells for in vitro diagnostic use. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E... Establishments That Manufacture Blood and Blood Products § 864.9225 Cell-freezing apparatus and reagents for in...
21 CFR 864.9225 - Cell-freezing apparatus and reagents for in vitro diagnostic use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... use are devices used to freeze human red blood cells for in vitro diagnostic use. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E... Establishments That Manufacture Blood and Blood Products § 864.9225 Cell-freezing apparatus and reagents for in...
ERIC Educational Resources Information Center
Wiederholt, Erwin
1983-01-01
DTA is a technique in which the temperature difference between sample/reference is measured as a function of temperature, while both are subject to a controlled temperature program. Use of a simple DTA-apparatus in demonstrating catalytic effects of manganese dioxide and aluminum oxide on decomposition temperature of potassium chlorate is…
On the energetics of the walking gait of a human operator using a passive exoskeleton apparatus
NASA Astrophysics Data System (ADS)
Lavrovskii, E. K.
2015-01-01
We study the energy expenditures and the peak values of control torques which a human operator must apply in the process of exoskeleton displacement for various types of regular, plane, and single-support gaits. The obtained results allow us to estimate the performance of the passive exoskeleton apparatus.
Team Electronic Gameplay Combining Different Means of Control
NASA Technical Reports Server (NTRS)
Palsson, Olafur S. (Inventor); Pope, Alan T. (Inventor)
2014-01-01
Disclosed are methods and apparatuses provided for modifying the effect of an operator controlled input device on an interactive device to encourage the self-regulation of at least one physiological activity by a person different than the operator. The interactive device comprises a display area which depicts images and apparatus for receiving at least one input from the operator controlled input device to thus permit the operator to control and interact with at least some of the depicted images. One effect modification comprises measurement of the physiological activity of a person different from the operator, while modifying the ability of the operator to control and interact with at least some of the depicted images by modifying the input from the operator controlled input device in response to changes in the measured physiological signal.
Method and apparatus for testing microfilaments
Schleitweiler, Patrick M.; Merten, Jr., Charles W.
1995-08-01
A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament.
Tensile-stressed microelectromechanical apparatus and micromirrors formed therefrom
Fleming, James G [Albuquerque, NM
2006-05-16
A microelectromechanical (MEM) apparatus is disclosed which includes one or more tensile-stressed actuators that are coupled through flexures to a stage on a substrate. The tensile-stressed actuators, which can be formed from tensile-stressed tungsten or silicon nitride, initially raise the stage above the substrate without any applied electrical voltage, and can then be used to control the height or tilt angle of the stage. An electrostatic actuator can also be used in combination with each tensile-stressed actuator. The MEM apparatus has applications for forming piston micromirrors or tiltable micromirrors and independently addressable arrays of such devices.
Apparatus for control of mercury
Downs, William; Bailey, Ralph T.
2001-01-01
A method and apparatus for reducing mercury in industrial gases such as the flue gas produced by the combustion of fossil fuels such as coal adds hydrogen sulfide to the flue gas in or just before a scrubber of the industrial process which contains the wet scrubber. The method and apparatus of the present invention is applicable to installations employing either wet or dry scrubber flue gas desulfurization systems. The present invention uses kraft green liquor as a source for hydrogen sulfide and/or the injection of mineral acids into the green liquor to release vaporous hydrogen sulfide in order to form mercury sulfide solids.
Apparatus for controlling molten core debris
Golden, Martin P. [Trafford, PA; Tilbrook, Roger W. [Monroeville, PA; Heylmun, Neal F. [Pittsburgh, PA
1977-07-19
Apparatus for containing, cooling, diluting, dispersing and maintaining subcritical the molten core debris assumed to melt through the bottom of a nuclear reactor pressure vessel in the unlikely event of a core meltdown. The apparatus is basically a sacrificial bed system which includes an inverted conical funnel, a core debris receptacle including a spherical dome, a spherically layered bed of primarily magnesia bricks, a cooling system of zig-zag piping in graphite blocks about and below the bed and a cylindrical liner surrounding the graphite blocks including a steel shell surrounded by firebrick. Tantalum absorber rods are used in the receptacle and bed.
The Commercial Vapor Diffusion Apparatus (CVDA) STS-95
NASA Technical Reports Server (NTRS)
2004-01-01
The Commercial Vapor Diffusion Apparatus will be used to perform 128 individual crystal growth investigations for commercial and science research. These experiments will grow crystals of several different proteins, including HIV-1 Protease Inhibitor, Glycogen Phosphorylase A, and NAD Synthetase. The Commercial Vapor Diffusion Apparatus supports multiple commercial investigations within a controlled environment. The goal of the Commercial Protein Crystal Growth payload on STS-95 is to grow large, high-quality crystals of several different proteins of interest to industry, and to continue to refine the technology and procedures used in microgravity for this important commercial research.
Sealed-bladdered chemical processing method and apparatus
Harless, D. Phillip
1999-01-01
A method and apparatus which enables a complete multi-stepped chemical treatment process to occur within a single, sealed-bladdered vessel 31. The entire chemical process occurs without interruption of the sealed-bladdered vessel 31 such as opening the sealed-bladdered vessel 31 between various steps of the process. The sealed-bladdered vessel 31 is loaded with a batch to be dissolved, treated, decanted, rinsed and/or dried. A pressure filtration step may also occur. The self-contained chemical processing apparatus 32 contains a sealed-bladder 32, a fluid pump 34, a reservoir 20, a compressed gas inlet, a vacuum pump 24, and a cold trap 23 as well as the associated piping 33, numerous valves 21,22,25,26,29,30,35,36 and other controls associated with such an apparatus. The claimed invention allows for dissolution and/or chemical treatment without the operator of the self-contained chemical processing apparatus 38 coming into contact with any of the process materials.
Li, Manfeng; Zhang, Hua; Ju, Yonglin
2012-07-01
A double-sided guarded hot plate apparatus (GHP) is specifically designed, fabricated, and constructed for the measurement of thermal conductivities of insulation specimens operated down to liquid nitrogen temperature (-196 °C), at different controlled pressures from 0.005 Pa to 0.105 MPa. The specimens placed in this apparatus are 300 mm in diameter at various thicknesses ranging from 4 mm to 40 mm. The apparatus is different from traditional GHP in terms of structure, supporting and heating method. The details of the design and construction of the hot plate, the cold plates, the suspensions, the clampings, and the vacuum chamber of the system are presented. The measurement methods of the temperatures, the input power, the meter area, and the thickness of the specimens are given. The apparatus is calibrated with teflon plates as sample and the maximum deviation from the published data is about 6% for thermal conductivity. The uncertainties for the measurement are also discussed in this paper.
Atomizing apparatus for making polymer and metal powders and whiskers
Otaigbe, Joshua U.; McAvoy, Jon M.; Anderson, Iver E.; Ting, Jason; Mi, Jia; Terpstra, Robert
2003-03-18
Method for making polymer particulates, such as spherical powder and whiskers, by melting a polymer material under conditions to avoid thermal degradation of the polymer material, atomizing the melt using gas jet means in a manner to form atomized droplets, and cooling the droplets to form polymer particulates, which are collected for further processing. Atomization parameters can be controlled to produce polymer particulates with controlled particle shape, particle size, and particle size distribution. For example, atomization parameters can be controlled to produce spherical polymer powders, polymer whiskers, and combinations of spherical powders and whiskers. Atomizing apparatus also is provided for atoomizing polymer and metallic materials.
Welding apparatus and methods for using ultrasonic sensing
McJunkin, Timothy R.; Johnson, John A.; Larsen, Eric D.; Smartt, Herschel B.
2006-08-22
A welding apparatus using ultrasonic sensing is described and which includes a movable welder having a selectively adjustable welding head for forming a partially completed weld in a weld seam defined between adjoining metal substrates; an ultrasonic assembly borne by the moveable welder and which is operable to generate an ultrasonic signal which is directed toward the partially completed weld, and is further reflected from same; and a controller electrically coupled with the ultrasonic assembly and controllably coupled with the welding head, and wherein the controller receives information regarding the ultrasonic signal and in response to the information optimally positions the welding head relative to the weld seam.
Tremblay, Jan-Alexis; Beaubien-Souligny, William; Elmi-Sarabi, Mahsa; Desjardins, Georges; Denault, André Y
2017-10-15
This article describes 2 patients with severe acute right ventricular failure causing circulatory shock. Portal vein pulsatility assessed by bedside ultrasonography suggested clinically relevant venous congestion. Management included cardiac preload reduction and combined inhalation of milrinone and epoprostenol to reduce right ventricular afterload. Portal vein ultrasonography may be useful in assessing right ventricular function in the acutely ill patient.
NASA Astrophysics Data System (ADS)
Kallis, Karoline; Kreppner, Stephan; Lotter, Michael; Fietkau, Rainer; Strnad, Vratislav; Bert, Christoph
2018-05-01
Multi-catheter interstitial brachytherapy (iBT) is a treatment option for breast cancer patients after breast conserving surgery. Typically, only a few additional quality interventions after the first irradiation have been introduced to ensure the planned treatment delivery. Therefore, the purpose of this study is to show the possibilities of an electromagnetic tracking (EMT) system integrated into the afterloader for quality assurance (QA) in high-dose rate (HDR) iBT of patients with breast cancer. The hybrid afterloader system equipped with an electromagnetic sensor was used for all phantom and patient measurements. Phantom measurements were conducted to estimate the quality of different evaluation schemes. After a coherent point drift registration of the EMT traces to the reconstructed catheters based on computed tomograms the dwell positions (DP) were defined. Different fitting and interpolation methods were analyzed for the reconstruction of DPs. All estimated DPs were compared to the DPs defined in treatment planning. Until now, the implant geometry of 20 patients treated with HDR brachytherapy was acquired and explored. Regarding the reconstruction techniques, both fitting and interpolation were able to detect manually introduced shifts and swaps. Nonetheless, interpolation showed superior results (RMSE = 1.27 mm), whereas fitting seemed to be more stable to distortion and motion. The EMT system proved to be beneficial for QA in brachytherapy and furthermore, clinical feasibility was proven.
In vitro evaluation of the effect of aortic compliance on pediatric intra-aortic balloon pumping.
Minich, L L; Tani, L Y; Hawkins, J A; Bartkowiak, R R; Royall, M L; Pantalos, G M
2001-04-01
OBJECTIVES: To evaluate the effect of aortic compliance on pediatric intra-aortic balloon pumping (IABP). DESIGN: In vitro study using a mechanical model of the pediatric left heart circulation. SETTING: Cardiovascular fluid dynamics research laboratory. SUBJECT: Pulsatile flow system simulating the pediatric left heart circulation and two different aortas with compliances comparable to those of the pediatric aorta (0.12 and 0.07 mL/mm Hg). INTERVENTIONS: Measurements were made at a baseline peak aortic flow of 4 L/min, at simulated shock (1.7 L/min), and with 1:1 IABP (rates, 130 and 150 bpm; balloon volumes, 2.5 and 5.0 mL). MEASUREMENTS AND MAIN RESULTS: Peak flow rates were measured in the ascending aorta, coronary arterial system, and brachiocephalic arterial systems. Aortic pressure was measured in the ascending aorta. For both aortas (0.12 and 0.07 mL/mm Hg), IABP resulted in diastolic augmentation (38 +/- 8 and 43 +/- 16 mm Hg) and afterload reduction (4 +/- 2 and 6 +/- 3 mm Hg). For both aortas, compared to shock, IABP resulted in significant increases in coronary arterial and brachiocephalic arterial flow and aortic pressure for both aortas. Aortic flow significantly increased only in the less-compliant aorta. CONCLUSIONS: In a laboratory model of pediatric left heart circulation, IABP results in diastolic augmentation, afterload reduction, and improved hemodynamics, even in aortas of greater compliance.
Eaton, Jennifer L; Zhang, Xingqi; Barnes, Randall B
2014-11-01
To compare live birth rates following ultrasound-guided embryo transfer (ET) by reproductive endocrinology and infertility fellows versus attending physicians. Women who underwent their first day-3, fresh, nondonor ET between Oct. 1, 2005, and April 1, 2011, at our academic center were included in this retrospective cohort study. Embryos were designated high quality if they had 8 cells, less than 10% fragmentation, and no asymmetry. ET was performed with the afterload technique under ultrasound guidance. Categorical variables were evaluated with the χ(2) test and continuous variables with the Student t test. Logistic regression was performed to assess the relationship between ET physician and live birth rate while adjusting for potential confounders. Seven hundred sixty women underwent ET by an attending physician, and 104 by a fellow. Baseline characteristics were similar between the groups. The live birth rate was 31% following ET by an attending physician, compared with 34% following ET by a fellow (P = .65). Logistic regression adjusting for potential confounders demonstrated no significant association between ET physician and live birth rate. This retrospective study demonstrated no significant difference in live birth rates following ultrasound-guided ET by fellows vs attending physicians at our institution. These data suggest that academic practices using the afterload method and ultrasound guidance can train fellows to perform ET without compromising success rates. Copyright © 2014 Elsevier Inc. All rights reserved.
Blumrich, Matthias A.; Salapura, Valentina
2010-11-02
An apparatus and method are disclosed for single-stepping coherence events in a multiprocessor system under software control in order to monitor the behavior of a memory coherence mechanism. Single-stepping coherence events in a multiprocessor system is made possible by adding one or more step registers. By accessing these step registers, one or more coherence requests are processed by the multiprocessor system. The step registers determine if the snoop unit will operate by proceeding in a normal execution mode, or operate in a single-step mode.
Ryon, A.D.; Haas, P.A.; Vavruska, J.S.
1982-01-19
The present invention is directed to a method and apparatus for making a population of dense, closely size-controlled microspheres by sol-gel procedures wherein said microspheres are characterized by a significant percentage of said population being within a predetermined, relatively narrow size range. This is accomplished by subjecting aqueous dispersions of a sol, within a water-immiscible organic liquid to a turbulent flow. Microsphere populations thus provided are useful in vibratory-packed processes for nuclear fuels to be irradiated in LWR- and FBR-type nuclear reactors.
Solder dross removal apparatus
NASA Technical Reports Server (NTRS)
Webb, Winston S. (Inventor)
1992-01-01
An automatic dross removal apparatus (10) is disclosed for removing dross from the surface of a solder bath (22) in an automated electric component handling system. A rotatable wiper blade (14) is positioned adjacent the solder bath (22) which skims the dross off of the surface prior to the dipping of a robot conveyed component into the bath. An electronic control circuit (34) causes a motor (32) to rotate the wiper arm (14) one full rotational cycle each time a pulse is received from a robot controller (44) as a component approaches the solder bath (22).
Automatic toilet seat lowering apparatus
Guerty, Harold G.
1994-09-06
A toilet seat lowering apparatus includes a housing defining an internal cavity for receiving water from the water supply line to the toilet holding tank. A descent delay assembly of the apparatus can include a stationary dam member and a rotating dam member for dividing the internal cavity into an inlet chamber and an outlet chamber and controlling the intake and evacuation of water in a delayed fashion. A descent initiator is activated when the internal cavity is filled with pressurized water and automatically begins the lowering of the toilet seat from its upright position, which lowering is also controlled by the descent delay assembly. In an alternative embodiment, the descent initiator and the descent delay assembly can be combined in a piston linked to the rotating dam member and provided with a water channel for creating a resisting pressure to the advancing piston and thereby slowing the associated descent of the toilet seat. A toilet seat lowering apparatus includes a housing defining an internal cavity for receiving water from the water supply line to the toilet holding tank. A descent delay assembly of the apparatus can include a stationary dam member and a rotating dam member for dividing the internal cavity into an inlet chamber and an outlet chamber and controlling the intake and evacuation of water in a delayed fashion. A descent initiator is activated when the internal cavity is filled with pressurized water and automatically begins the lowering of the toilet seat from its upright position, which lowering is also controlled by the descent delay assembly. In an alternative embodiment, the descent initiator and the descent delay assembly can be combined in a piston linked to the rotating dam member and provided with a water channel for creating a resisting pressure to the advancing piston and thereby slowing the associated descent of the toilet seat.
Automated apparatus for producing gradient gels
Anderson, N.L.
1983-11-10
Apparatus for producing a gradient gel which serves as a standard medium for a two-dimensional analysis of proteins, the gel having a density gradient along its height formed by a variation in gel composition, with the apparatus including first and second pumping means each including a plurality of pumps on a common shaft and driven by a stepping motor capable of providing small incremental changes in pump outputs for the gel ingredients, the motors being controlled, by digital signals from a digital computer, a hollow form or cassette for receiving the gel composition, means for transferring the gel composition including a filler tube extending near the bottom of the cassette, adjustable horizontal and vertical arms for automatically removing and relocating the filler tube in the next cassette, and a digital computer programmed to automatically control the stepping motors, arm movements, and associated sensing operations involving the filling operation.
Automated apparatus for producing gradient gels
Anderson, Norman L.
1986-01-01
Apparatus for producing a gradient gel which serves as a standard medium for a two-dimensional analysis of proteins, the gel having a density gradient along its height formed by a variation in gel composition, with the apparatus including first and second pumping means each including a plurality of pumps on a common shaft and driven by a stepping motor capable of providing small incremental changes in pump outputs for the gel ingredients, the motors being controlled, by digital signals from a digital computer, a hollow form or cassette for receiving the gel composition, means for transferring the gel composition including a filler tube extending near the bottom of the cassette, adjustable horizontal and vertical arms for automatically removing and relocating the filler tube in the next cassette, and a digital computer programmed to automatically control the stepping motors, arm movements, and associated sensing operations involving the filling operation.
Tuning Shear Jamming by Basal Assisted Couette Shear
NASA Astrophysics Data System (ADS)
Zhao, Yiqiu; Barés, Jonathan; Behringer, Robert
Granular matter with packing fraction ϕS < ϕ <ϕJ can be jammed by applying shear strain. However, the stress-strain relation in shear jamming transition is not very well understood. Part of the difficulty is that the strain inside the granular system is very complicated and hard to control. In this work, by using a novel Couette shear apparatus capable of generating arbitrary shear profiles, we study the stress-strain relation during shear jamming transition for granular system under different kinds of controlled interior strain. The novel Couette shear apparatus consists of 21 independently movable rings and two circular boundaries. The apparatus can shear the granular sample not only from the boundaries but also from the bottom. The granular sample is made of about 2000 bi-disperse photo elastic disks, making it possible to extract force information. This work is supported by NSF-DMR1206351, DMS1248071, NASA NNX15AD38G.
Playground Apparatus Experience and Muscular Endurance among Children 4-6.
ERIC Educational Resources Information Center
Gabbard, Carl
The effects of specific play apparatus experience on a test of upper body muscular endurance was investigated among a group of children 4-6 years old. Both the control and experimental group consisted of 45 subjects randomly selected on the basis of age from two private day care centers situated in the same community. The two groups were of…
Controlling the Internal Heat Transfer Coefficient by the Characteristics of External Flows
NASA Astrophysics Data System (ADS)
Zhuromskii, V. M.
2018-01-01
The engineering-physical fundamentals of substance synthesis in a boiling apparatus are presented. We have modeled a system of automatic stabilization of the maximum internal heat transfer coefficient in such an apparatus by the characteristics of external flows on the basis of adaptive seeking algorithms. The results of operation of the system in the shop are presented.
INVESTIGATION OF THE SUN'S X-RAYS. III. ELECTRONIC APPARATUS (in Russian)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasil'ev, B.N.; Shurigin, A.I.; Tindo, I.P.
1963-01-01
The electronic portion of an apparatus constructed for the investigation of soft x rays being emitted by the sun is described. The apparatus is used in geophysical rockets and in cosmic space ships and earth satellites. In the geophysical rockets two separate detection channels are employed, one for the working counters and the other for the control counters. The working counter is always directed towards the sun while the control counter is turned 15 deg away from the sun. In the second Sputnik six identical counters were used and arranged so that their line of sight was oriented along threemore » mutually perpendicular axes. In the third Sputnik the working and contour counters were distributed in a system which was self-orienting with respect to the sun. In addition, two stationary counters were enrployed; their direction with respect to the sun changed during the course of the flight. The electronic apparatus consists of the following basic components: a circuit that forms the amplitude and shape of the counter pulses, the triggering device, the separating cascade circuit, and the coding set-up. Each of these circuits is described in detail; block diagrams are shown. (TTT)« less
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Ortiz, John P.
1986-01-01
An apparatus for measuring the overall decontamination factor of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Ortiz, J.P.
1985-07-03
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.
NASA Technical Reports Server (NTRS)
Palsson, Olafur S. (Inventor); Harris, Randall L., Sr. (Inventor); Pope, Alan T. (Inventor)
2002-01-01
Apparatus and methods for modulating the control authority (i.e., control function) of a computer simulation or game input device (e.g., joystick, button control) using physiological information so as to affect the user's ability to impact or control the simulation or game with the input device. One aspect is to use the present invention, along with a computer simulation or game, to affect physiological state or physiological self-regulation according to some programmed criterion (e.g., increase, decrease, or maintain) in order to perform better at the game task. When the affected physiological state or physiological self-regulation is the target of self-regulation or biofeedback training, the simulation or game play reinforces therapeutic changes in the physiological signal(s).
Method and apparatus for the control of fluid dynamic mixing in pulse combustors
Bramlette, T.T.; Keller, J.O.
1992-06-02
In a method and apparatus for controlling total ignition delay time in a pulse combustor, and thus controlling the mixing characteristics of the combustion reactants and the combustion products in the combustor, the total ignition delay time is controlled by adjusting the inlet geometry of the inlet to the combustion chamber. The inlet geometry may be fixed or variable for controlling the mixing characteristics. A feedback loop may be employed to sense actual combustion characteristics, and, in response to the sensed combustion characteristics, the inlet geometry may be varied to obtain the total ignition delay time necessary to achieve the desired combustion characteristics. Various embodiments relate to the varying of the mass flow rate of reactants while holding the radius/velocity ratio constant. 10 figs.
Method and apparatus for the control of fluid dynamic mixing in pulse combustors
Bramlette, T. Tazwell; Keller, Jay O.
1992-06-02
In a method and apparatus for controlling total ignition delay time in a pulse combustor, and thus controlling the mixing characteristics of the combustion reactants and the combustion products in the combustor, the total ignition delay time is controlled by adjusting the inlet geometry of the inlet to the combustion chamber. The inlet geometry may be fixed or variable for controlling the mixing characteristics. A feedback loop may be employed to sense actual combustion characteristics, and, in response to the sensed combustion characteristics, the inlet geometry may be varied to obtain the total ignition delay time necessary to achieve the desired combustion characteristics. Various embodiments relate to the varying of the mass flow rate of reactants while holding the radius/velocity ratio constant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Awunor, O., E-mail: onuora.awunor@stees.nhs.uk; Berger, D.; Kirisits, C.
Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Irmore » source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation associated with the source position reproducibility was within ±1.0 mm for all afterloaders. Maximum source positional variations of 2.1 and 3.9, 1.8 and 5.4, and 2.3 and 3.4 mm were observed at standard treatment positions for the Ø26, Ø30, and Ø32 mm sized 45° and 60° rings, respectively. Mean positional differences between a majority of the rings were within ±1.0 mm. Mean positional differences between a majority of the intracenter ring sets were within the expanded measurement uncertainty. When comparing the 45°–60° source paths, mean differences of 1.6, 0.9, and 0.9 mm were observed across the Ø26, Ø30 (MicroSelectron), and Ø32 mm (GammaMed) rings, respectively. When comparing to manufacturer source path models, maximum offsets of 1.9 and 2.1, 2.6 and 2.3, and 0.8 and 1.6 mm were observed for the Ø26, Ø30 (MicroSelectron), and Ø30 mm (Flexitron) sized 45° and 60° rings, respectively. When comparing the audit to ring commissioning data of participating centers, mean differences of up to 2.4 mm were observed. Conclusions: A majority of the audited rings showed a good degree of manufacturer consistency; however, substantial positional variation observed between some rings emphasizes the importance of commissioning each ring before clinical use. Differences observed between audit and commissioning data also indicate some variation in source treatment positions across centers.« less
Control apparatus and method for efficiently heating a fuel processor in a fuel cell system
Doan, Tien M.; Clingerman, Bruce J.
2003-08-05
A control apparatus and method for efficiently controlling the amount of heat generated by a fuel cell processor in a fuel cell system by determining a temperature error between actual and desired fuel processor temperatures. The temperature error is converted to a combustor fuel injector command signal or a heat dump valve position command signal depending upon the type of temperature error. Logic controls are responsive to the combustor fuel injector command signals and the heat dump valve position command signal to prevent the combustor fuel injector command signal from being generated if the heat dump valve is opened or, alternately, from preventing the heat dump valve position command signal from being generated if the combustor fuel injector is opened.
Method and apparatus for managing access to a memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeBenedictis, Erik
A method and apparatus for managing access to a memory of a computing system. A controller transforms a plurality of operations that represent a computing job into an operational memory layout that reduces a size of a selected portion of the memory that needs to be accessed to perform the computing job. The controller stores the operational memory layout in a plurality of memory cells within the selected portion of the memory. The controller controls a sequence by which a processor in the computing system accesses the memory to perform the computing job using the operational memory layout. The operationalmore » memory layout reduces an amount of energy consumed by the processor to perform the computing job.« less
Apparatus and method for forming a workpiece surface into a non-rotationally symmetric shape
Dow, Thomas A.; Garrard, Kenneth P.; Moorefield, II, George M.; Taylor, Lauren W.
1995-11-21
A turning machine includes a controller for generating both aspherical and non-symmetrical shape components defining the predetermined shape, and a controller for controlling a spindle and a positionable cutting blade to thereby form a predetermined non-rotationally symmetric shape in a workpiece surface. The apparatus includes a rotatable spindle for rotatably mounting the workpiece about an axis, a spindle encoder for sensing an angular position of the rotating workpiece, the cutting blade, and radial and transverse positioners for relatively positioning the cutting blade and workpiece along respective radial and transverse directions. The controller cooperates with a fast transverse positioner for positioning the cutting blade in predetermined varying transverse positions during a revolution of the workpiece.
Polarization imaging apparatus
NASA Technical Reports Server (NTRS)
Zou, Yingyin Kevin (Inventor); Chen, Qiushui (Inventor); Zhao, Hongzhi (Inventor)
2010-01-01
A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set 11, a linear polarizer 14 with its optical axis 18, a first variable phase retarder 12 with its optical axis 16 aligned 22.5.degree. to axis 18, a second variable phase retarder 13 with its optical axis 17 aligned 45.degree. to axis 18, a imaging sensor 15 for sensing the intensity images of the sample, a controller 101 and a computer 102. Two variable phase retarders 12 and 13 were controlled independently by a computer 102 through a controller unit 101 which generates a sequential of voltages to control the phase retardations of VPRs 12 and 13. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor 15 when the phase retardations of VPRs 12 and 13 were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.
Multiple network interface core apparatus and method
Underwood, Keith D [Albuquerque, NM; Hemmert, Karl Scott [Albuquerque, NM
2011-04-26
A network interface controller and network interface control method comprising providing a single integrated circuit as a network interface controller and employing a plurality of network interface cores on the single integrated circuit.
Oncentra brachytherapy planning system.
Yang, Jack
2018-03-27
In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of several clinical sample cases were discussed to illustrate the effectiveness and clinical efficacy. The American Association of Physicists in Medicine brachytherapy reports of TG-43 and TG-186 were also described and compared in evaluations of fundamental calculation methodologies. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Method and apparatus for testing microfilaments
Schleitweiler, P.M.; Merten, C.W. Jr.
1995-08-01
A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament. 2 figs.
Microelectromechanical ratcheting apparatus
Barnes, Stephen M.; Miller, Samuel L.; Jensen, Brian D.; Rodgers, M. Steven; Burg, Michael S.
2001-01-01
A microelectromechanical (MEM) ratcheting apparatus is disclosed which includes an electrostatic or thermal actuator that drives a moveable member in the form of a ring gear, stage, or rack. Motion is effected by one or more reciprocating pawls driven by the actuator in a direction that is parallel to, in line with, or tangential to the path. The reciprocating pawls engage indexing elements (e.g. teeth or pins) on the moveable member to incrementally move the member along a curved or straight path with the ability to precisely control and determine the position of the moveable member. The MEM apparatus can be formed on a silicon substrate by conventional surface micromachining methods.
Power control apparatus and methods for electric vehicles
Gadh, Rajit; Chung, Ching-Yen; Chu, Chi-Cheng; Qiu, Li
2016-03-22
Electric vehicle (EV) charging apparatus and methods are described which allow the sharing of charge current between multiple vehicles connected to a single source of charging energy. In addition, this charge sharing can be performed in a grid-friendly manner by lowering current supplied to EVs when necessary in order to satisfy the needs of the grid, or building operator. The apparatus and methods can be integrated into charging stations or can be implemented with a middle-man approach in which a multiple EV charging box, which includes an EV emulator and multiple pilot signal generation circuits, is coupled to a single EV charge station.
Gram staining apparatus for space station applications
NASA Technical Reports Server (NTRS)
Molina, T. C.; Brown, H. D.; Irbe, R. M.; Pierson, D. L.
1990-01-01
A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space.
Method and apparatus for combinatorial chemistry
Foote, Robert S.
2007-02-20
A method and apparatus are provided for performing light-directed reactions in spatially addressable channels within a plurality of channels. One aspect of the invention employs photoactivatable reagents in solutions disposed into spatially addressable flow streams to control the parallel synthesis of molecules immobilized within the channels. The reagents may be photoactivated within a subset of channels at the site of immobilized substrate molecules or at a light-addressable site upstream from the substrate molecules. The method and apparatus of the invention find particularly utility in the synthesis of biopolymer arrays, e.g., oligonucleotides, peptides and carbohydrates, and in the combinatorial synthesis of small molecule arrays for drug discovery.
Method and apparatus for combinatorial chemistry
Foote, Robert S [Oak Ridge, TN
2012-06-05
A method and apparatus are provided for performing light-directed reactions in spatially addressable channels within a plurality of channels. One aspect of the invention employs photoactivatable reagents in solutions disposed into spatially addressable flow streams to control the parallel synthesis of molecules immobilized within the channels. The reagents may be photoactivated within a subset of channels at the site of immobilized substrate molecules or at a light-addressable site upstream from the substrate molecules. The method and apparatus of the invention find particularly utility in the synthesis of biopolymer arrays, e.g., oligonucleotides, peptides and carbohydrates, and in the combinatorial synthesis of small molecule arrays for drug discovery.
Dual initiation strip charge apparatus and methods for making and implementing the same
Jakaboski, Juan-Carlos [Albuquerque, NM; Todd,; Steven, N [Rio Rancho, NM; Polisar, Stephen [Albuquerque, NM; Hughs, Chance [Tijeras, NM
2011-03-22
A Dual Initiation Strip Charge (DISC) apparatus is initiated by a single initiation source and detonates a strip of explosive charge at two separate contacts. The reflection of explosively induced stresses meet and create a fracture and breach a target along a generally single fracture contour and produce generally fragment-free scattering and no spallation. Methods for making and implementing a DISC apparatus provide numerous advantages over previous methods of creating explosive charges by utilizing steps for rapid prototyping; by implementing efficient steps and designs for metering consistent, repeatable, and controlled amount of high explosive; and by utilizing readily available materials.
Apparatus for controlling molten core debris. [LMFBR
Golden, M.P.; Tilbrook, R.W.; Heylmun, N.F.
1977-07-19
Disclosed is an apparatus for containing, cooling, diluting, dispersing and maintaining subcritical the molten core debris assumed to melt through the bottom of a nuclear reactor pressure vessel in the unlikely event of a core meltdown. The apparatus is basically a sacrificial bed system which includes an inverted conical funnel, a core debris receptacle including a spherical dome, a spherically layered bed of primarily magnesia bricks, a cooling system of zig-zag piping in graphite blocks about and below the bed and a cylindrical liner surrounding the graphite blocks including a steel shell surrounded by firebrick. Tantalum absorber rods are used in the receptacle and bed. 9 claims, 22 figures.
Automated apparatus for solvent separation of a coal liquefaction product stream
Schweighardt, Frank K.
1985-01-01
An automated apparatus for the solvent separation of a coal liquefaction product stream that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In use of the apparatus, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control means. The mixture in the filter is agitated by means of ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process.
Smits, Kathleen; Eagen, Victoria; Trautz, Andrew
2015-01-01
Evaporation is directly influenced by the interactions between the atmosphere, land surface and soil subsurface. This work aims to experimentally study evaporation under various surface boundary conditions to improve our current understanding and characterization of this multiphase phenomenon as well as to validate numerical heat and mass transfer theories that couple Navier-Stokes flow in the atmosphere and Darcian flow in the porous media. Experimental data were collected using a unique soil tank apparatus interfaced with a small climate controlled wind tunnel. The experimental apparatus was instrumented with a suite of state of the art sensor technologies for the continuous and autonomous collection of soil moisture, soil thermal properties, soil and air temperature, relative humidity, and wind speed. This experimental apparatus can be used to generate data under well controlled boundary conditions, allowing for better control and gathering of accurate data at scales of interest not feasible in the field. Induced airflow at several distinct wind speeds over the soil surface resulted in unique behavior of heat and mass transfer during the different evaporative stages. PMID:26131928
Apparatuses and methods for laser reading of thermoluminescent phosphors
Braunlich, Peter F.; Tetzlaff, Wolfgang
1989-01-01
Apparatuses and methods for rapidly reading thermoluminescent phosphors to determine the amount of luminescent energy stored therein. The stored luminescent energy is interpreted as a measure of the total exposure of the thermoluminescent phosphor to ionizing radiation. The thermoluminescent phosphor reading apparatus uses a laser to generate a laser beam. The laser beam power level is monitored by a laser power detector and controlled to maintain the power level at a desired value or values which can vary with time. A shutter or other laser beam interrupting means is used to control exposure of the thermoluminescent phosphor to the laser beam. The laser beam can be equalized using an opitcal equalizer so that the laser beam has an approximately uniform power density across the beam. The heated thermoluminescent phosphor emits a visible or otherwise detectable luminescent emission which is measured as an indication of the radiation exposure of the thermoluminscent phosphors. Also disclosed are preferred signal processing and control circuits including one system using a digital computer. Also disclosed are time-profiled laser power cycles for pre-anneal, read and post-anneal treatment of phosphors.
Apparatus and method for biological purification of waste
Lucido, John A.; Keenan, Daniel; Premuzic, Eugene T.; Lin, Mow S.; Shelenkova, Ludmila
1998-11-24
An apparatus is disclosed for containing a microorganism culture in an active exponential growth and delivering a supply of microorganisms to an environment containing wastes for bio-augmenting the biodegradation of the wastes. The apparatus comprises a bioreactor and an operably connected controller. The bioreactor has a bioreactor chamber for containing a supply of microorganisms, a second chamber for containing a supply of water and inorganic nutrients, and a third chamber for containing a supply of organic nutrients. The bioreactor is operably connected to the controller in which a first pump is operably connected in fluid communication between the bioreactor chamber and the second chamber and third chamber, and a second pump is operably connected in fluid communication between the bioreactor chamber and the environment containing wastes to be biodegraded. The controller further includes a timer and regulator operably connected to the first and second pumps to effectively maintain the microorganisms in exponential growth in the bioreactor chamber and to deliver microorganisms to an environment to be treated. Also, disclosed is a method for bio-augmenting the biodegradation of wastes.
Apparatus and method for biological purification of waste
Lucido, J.A.; Keenan, D.; Premuzic, E.T.; Lin, M.S.; Shelenkova, L.
1998-11-24
An apparatus is disclosed for containing a microorganism culture in an active exponential growth and delivering a supply of microorganisms to an environment containing wastes for bio-augmenting the biodegradation of the wastes. The apparatus comprises a bioreactor and an operably connected controller. The bioreactor has a bioreactor chamber for containing a supply of microorganisms, a second chamber for containing a supply of water and inorganic nutrients, and a third chamber for containing a supply of organic nutrients. The bioreactor is operably connected to the controller in which a first pump is operably connected in fluid communication between the bioreactor chamber and the second chamber and third chamber, and a second pump is operably connected in fluid communication between the bioreactor chamber and the environment containing wastes to be biodegraded. The controller further includes a timer and regulator operably connected to the first and second pumps to effectively maintain the microorganisms in exponential growth in the bioreactor chamber and to deliver microorganisms to an environment to be treated. Also, disclosed is a method for bio-augmenting the biodegradation of wastes. 7 figs.
A nursing diagnosis approach to the patient awaiting cardiac transplantation.
Cardin, S; Clark, S
1985-09-01
The most common reason to perform cardiac transplantation is dilated cardiomyopathy. Alterations in cardiac output secondary to decreased contractility and increased preload and afterload will, over time, lead to progressive deterioration of the patient with this type of end-stage cardiac disease. Heart transplantation is now an accepted therapy for these patients. This article focused on the patient in the period awaiting cardiac transplantation. Five pertinent nursing diagnoses were identified and discussed. A case study approach was utilized to highlight patient problems and nursing interventions.
NASA Astrophysics Data System (ADS)
Li, Minghui; Yin, Guangzhi; Xu, Jiang; Li, Wenpu; Song, Zhenlong; Jiang, Changbao
2016-12-01
Fluid-solid coupling investigations of the geological storage of CO2, efficient unconventional oil and natural gas exploitations are mostly conducted under conventional triaxial stress conditions ( σ 2 = σ 3), ignoring the effects of σ 2 on the geomechanical properties and permeability of rocks (shale, coal and sandstone). A novel multi-functional true triaxial geophysical (TTG) apparatus was designed, fabricated, calibrated and tested to simulate true triaxial stress ( σ 1 > σ 2 > σ 3) conditions and to reveal geomechanical properties and permeability evolutions of rocks. The apparatus was developed with the capacity to carry out geomechanical and fluid flow experiments at high three-dimensional loading forces and injection pressures under true triaxial stress conditions. The control and measurement of the fluid flow with effective sealing of rock specimen corners were achieved using a specially designed internally sealed fluid flow system. To validate that the apparatus works properly and to recognize the effects of each principal stress on rock deformation and permeability, stress-strain and permeability experiments and a hydraulic fracturing simulation experiment on shale specimens were conducted under true triaxial stress conditions using the TTG apparatus. Results show that the apparatus has advantages in recognizing the effects of σ 2 on the geomechanical properties and permeability of rocks. Results also demonstrate the effectiveness and reliability of the novel TTG apparatus. The apparatus provides a new method of studying the geomechanical properties and permeability evolutions of rocks under true triaxial stress conditions, promoting further investigations of the geological storage of CO2, efficient unconventional oil and gas exploitations.
NASA Technical Reports Server (NTRS)
Ives, R. E.
1982-01-01
A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.
Otaigbe, Joshua U.; McAvoy, Jon M.; Anderson, Iver E.; Ting, Jason; Mi, Jia; Terpstra, Robert
2001-01-09
Method for making polymer particulates, such as spherical powder and whiskers, by melting a polymer material under conditions to avoid thermal degradation of the polymer material, atomizing the melt using gas jet means in a manner to form atomized droplets, and cooling the droplets to form polymer particulates, which are collected for further processing. Atomization parameters can be controlled to produce polymer particulates with controlled particle shape, particle size, and particle size distribution. For example, atomization parameters can be controlled to produce spherical polymer powders, polymer whiskers, and combinations of spherical powders and whiskers. Atomizing apparatus also is provided for atoomizing polymer and metallic materials.
Engine Cylinder Temperature Control
Kilkenny, Jonathan Patrick; Duffy, Kevin Patrick
2005-09-27
A method and apparatus for controlling a temperature in a combustion cylinder in an internal combustion engine. The cylinder is fluidly connected to an intake manifold and an exhaust manifold. The method and apparatus includes increasing a back pressure associated with the exhaust manifold to a level sufficient to maintain a desired quantity of residual exhaust gas in the cylinder, and varying operation of an intake valve located between the intake manifold and the cylinder to an open duration sufficient to maintain a desired quantity of fresh air from the intake manifold to the cylinder, wherein controlling the quantities of residual exhaust gas and fresh air are performed to maintain the temperature in the cylinder at a desired level.
Dynamically controlled crystallization method and apparatus and crystals obtained thereby
NASA Technical Reports Server (NTRS)
Arnowitz, Leonard (Inventor); Steinberg, Emanuel (Inventor)
1999-01-01
A method and apparatus for dynamically controlling the crystallization of proteins including a crystallization chamber or chambers for holding a protein in a salt solution, one or more salt solution chambers, two communication passages respectively coupling the crystallization chamber with each of the salt solution chambers, and transfer mechanisms configured to respectively transfer salt solution between each of the salt solution chambers and the crystallization chamber. The transfer mechanisms are interlocked to maintain the volume of salt solution in the crystallization chamber substantially constant. Salt solution of different concentrations is transferred into and out of the crystallization chamber to adjust the salt concentration in the crystallization chamber to achieve precise control of the crystallization process.
Model Design for Water Wheel Control System of Heumgyeonggaknu
NASA Astrophysics Data System (ADS)
Kim, Sang Hyuk; Ham, Seon Young; Lee, Yong Sam
2016-03-01
Heumgyeonggaknu (????) is powered by a water-hammering-type water wheel. The technique that maintains the constant speed of the water wheel is assumed to be the one used in the Cheonhyeong (???) apparatus in Shui Yun Yi Xiang Tai (???) made by the Northern Song (??) dynasty in the 11th century. We investigated the history of the development and characteristics of the Cheonhyeong apparatus, and we analyzed ways to transmit the power of Heumgyeonggaknu. In addition, we carried out a conceptual design to systematically examine the power control system. Based on the conceptual design, we built a model for a water wheel control system that could be used in experiments by drawing a 3D model and a basic design.
NASA Astrophysics Data System (ADS)
Bozeman, Richard J., Jr.
1992-02-01
The invention discloses methods and apparatus for detecting vibrations from machines which indicate an impending malfunction for the purpose of preventing additional damage and allowing for an orderly shutdown or a change in mode of operation. The method and apparatus is especially suited for reliable operation in providing thruster control data concerning unstable vibration in an electrical environment which is typically noisy and in which unrecognized ground loops may exist.
NASA Astrophysics Data System (ADS)
Bozeman, Richard J., Jr.
1994-05-01
The invention discloses methods and apparatus for detecting vibrations from machines which indicate an impending malfunction for the purpose of preventing additional damage and allowing for an orderly shutdown or a change in mode of operation. The method and apparatus is especially suited for reliable operation in providing thruster control data concerning unstable vibration in an electrical environment which is typically noisy and in which unrecognized ground loops may exist.
Plasma/Neutral-Beam Etching Apparatus
NASA Technical Reports Server (NTRS)
Langer, William; Cohen, Samuel; Cuthbertson, John; Manos, Dennis; Motley, Robert
1989-01-01
Energies of neutral particles controllable. Apparatus developed to produce intense beams of reactant atoms for simulating low-Earth-orbit oxygen erosion, for studying beam-gas collisions, and for etching semiconductor substrates. Neutral beam formed by neutralization and reflection of accelerated plasma on metal plate. Plasma ejected from coaxial plasma gun toward neutralizing plate, where turned into beam of atoms or molecules and aimed at substrate to be etched.
Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms
NASA Technical Reports Server (NTRS)
Schubert, Wayne W.; Spry, James A.; Ronney, Paul D.; Pandian, Nathan R.; Welder, Eric
2012-01-01
The objective of this research was to design, build, and test an experimental apparatus for studying the parameters of atmospheric entry heating, and the inactivation of temperature-resistant bacterial spores. The apparatus is capable of controlled, rapid heating of sample coupons to temperatures of 200 to 350 C and above. The vacuum chamber permits operation under vacuum or special atmospheric gas mixtures.
Method and apparatus for pulse stacking
Harney, Robert C.
1977-01-01
An active pulse stacking system including an etalon and an electro-optical modulator apparatus combined with a pulse-forming network capable of forming and summing a sequence of time-delayed optical waveforms arising from, for example, a single laser pulse. The Pockels cell pulse stacker may attain an efficiency of about 2.6% while providing a controllable faster-than-exponential time rise in transmitted pulse intensity.
Pulsed source ion implantation apparatus and method
Leung, Ka-Ngo
1996-01-01
A new pulsed plasma-immersion ion-implantation apparatus that implants ions in large irregularly shaped objects to controllable depth without overheating the target, minimizing voltage breakdown, and using a constant electrical bias applied to the target. Instead of pulsing the voltage applied to the target, the plasma source, for example a tungsten filament or a RF antenna, is pulsed. Both electrically conducting and insulating targets can be implanted.
Smart accelerometer. [vibration damage detection
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1994-01-01
The invention discloses methods and apparatus for detecting vibrations from machines which indicate an impending malfunction for the purpose of preventing additional damage and allowing for an orderly shutdown or a change in mode of operation. The method and apparatus is especially suited for reliable operation in providing thruster control data concerning unstable vibration in an electrical environment which is typically noisy and in which unrecognized ground loops may exist.
Apparatus and method for handling magnetic particles in a fluid
Holman, David A.; Grate, Jay W.; Bruckner-Lea, Cynthia J.
2000-01-01
The present invention is an apparatus and method for handling magnetic particles suspended in a fluid, relying upon the known features of a magnetic flux conductor that is permeable thereby permitting the magnetic particles and fluid to flow therethrough; and a controllable magnetic field for the handling. The present invention is an improvement wherein the magnetic flux conductor is a monolithic porous foam.
Micromachine friction test apparatus
deBoer, Maarten P.; Redmond, James M.; Michalske, Terry A.
2002-01-01
A microelectromechanical (MEM) friction test apparatus is disclosed for determining static or dynamic friction in MEM devices. The friction test apparatus, formed by surface micromachining, is based on a friction pad supported at one end of a cantilevered beam, with the friction pad overlying a contact pad formed on the substrate. A first electrostatic actuator can be used to bring a lower surface of the friction pad into contact with an upper surface of the contact pad with a controlled and adjustable force of contact. A second electrostatic actuator can then be used to bend the cantilevered beam, thereby shortening its length and generating a relative motion between the two contacting surfaces. The displacement of the cantilevered beam can be measured optically and used to determine the static or dynamic friction, including frictional losses and the coefficient of friction between the surfaces. The test apparatus can also be used to assess the reliability of rubbing surfaces in MEM devices by producing and measuring wear of those surfaces. Finally, the friction test apparatus, which is small in size, can be used as an in situ process quality tool for improving the fabrication of MEM devices.
Operational experience of the OC-OTEC experiments at NELH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Link, H
1989-02-01
The Solar Energy Research Institute, under funding and program direction from the US Department of Energy, has been operating a small-scale test apparatus to investigate key components of open- cycle ocean thermal energy conversion (OC-OTEC). The apparatus started operations in October 1987 and continues to provide valuable information on heat-and mass-transfer processes in evaporators and condensers, gas sorption processes as seawater is depressurized and repressurized, and control and instrumentation characteristics of open-cycle systems. Although other test facilities have been used to study some of these interactions, this is the largest apparatus of its kind to use seawater since Georges Claude`smore » efforts in 1926. The information obtained from experiments conducted in this apparatus is being used to design a larger scale experiment in which a positive net power production is expected to be demonstrated for the first time with OC-OTEC. This paper describes the apparatus, the major tests conducted during its first 18 months of operation, and the experience gained in OC-OTEC system operation. 13 refs., 8 figs.« less
Gao, Fan; Rodriguez, Johanan; Kapp, Susan
2016-06-01
Harness fitting in the body-powered prosthesis remains more art than science due to a lack of consistent and quantitative evaluation. The aim of this study was to develop a mechanical, human-body-shaped apparatus to simulate body-powered upper limb prosthetic usage and evaluate its capability of quantitative examination of harness configuration. The apparatus was built upon a torso of a wooden mannequin and integrated major mechanical joints to simulate terminal device operation. Sensors were used to register cable tension, cable excursion, and grip force simultaneously. The apparatus allowed the scapula to move up to 127 mm laterally and the load cell can measure the cable tension up to 445 N. Our preliminary evaluation highlighted the needs and importance of investigating harness configurations in a systematic and controllable manner. The apparatus allows objective, systematic, and quantitative evaluation of effects of realistic harness configurations and will provide insightful and working knowledge on harness fitting in upper limb amputees using body-powered prosthesis. © The International Society for Prosthetics and Orthotics 2015.
NASA Technical Reports Server (NTRS)
Buehler, Martin (Inventor)
2009-01-01
An electro-active sensor includes a nonconductive platform with a first electrode set attached with a first side of a nonconductive platform. The first electrode set serves as an electrochemical cell that may be utilized to detect electro-active species in solution. A plurality of electrode sets and a variety of additional electrochemical cells and sensors may be attached with the nonconductive platform. The present invention also includes a method for constructing the aforementioned electro-active sensor. Additionally, an apparatus for detection and observation is disclosed, where the apparatus includes a sealable chamber for insertion of a portion of an electro-active sensor. The apparatus allows for monitoring and detection activities. Allowing for control of attached cells and sensors, a dual-mode circuitry is also disclosed. The dual-mode circuitry includes a switch, allowing the circuitry to be switched from a potentiostat to a galvanostat mode.
Method and apparatus for use in making an object
NASA Technical Reports Server (NTRS)
Derkacs, Thomas (Inventor); Fetheroff, Charles W. (Inventor); Matay, Istvan M. (Inventor); Toth, Istvan J. (Inventor)
1982-01-01
Although the method and apparatus of the present invention can be utilized to apply either a uniform or a nonuniform covering of material over many different workpieces, the apparatus (20) is advantageously utilized to apply a thermal barrier covering (64) to an airfoil (22) which is used in a turbine engine. The airfoil is held by a gripper assembly (86) while a spray gun (24) is effective to apply the covering over the airfoil. When a portion of the covering has been applied, a sensor (28) is utilized to detect the thickness of the covering. A control apparatus (32) compares the thickness of the covering of material which has been applied with the desired thickness and is subsequently effective to regulate the operation of the spray gun to adaptively apply a covering of a desired thickness with an accuracy of at least plus or minus 0.0015 inches (1.5 mils) despite unanticipated process variations.
Harrison, Thomas R.
1989-08-22
A proximity fuze system includes an optical ranging apparatus, a detonation circuit controlled by the optical ranging apparatus, and an explosive charge detonated by the detonation cirtcuit. The optical ranging apparatus includes a pulsed laser light source for generating target ranging light pulses and optical reference light pulses. A single lens directs ranging pulses to a target and collects reflected light from the target. An optical fiber bundle is used for delaying the optical reference pulses to correspond to a predetermined distance from the target. The optical ranging apparatus includes circuitry for providing a first signal depending upon the light pulses reflected from the target, a second signal depending upon the light pulses from the optical delay fiber bundle, and an output signal when the first and second signals coincide with each other. The output signal occurs when the distance from the target is equal to the predetermined distance form the target. Additional circuitry distinguishes pulses reflected from the target from background solar radiation.
Apparatus for measurements of thermal and optical stimulated exo-electron emission and luminescence
NASA Astrophysics Data System (ADS)
Pokorný, P.; Novotný, M.; Fitl, P.; Zuklín, J.; Vlček, J.; Nikl, J.; Marešová, E.; Hruška, P.; Bulíř, J.; Drahokoupil, J.; Čerňanský, M.; Lančok, J.
2018-06-01
The purpose of the design, construction and implementation of vacuum apparatus for measuring simultaneously three or more stimulated phenomena in dielectrics and eventually semiconductors is to investigate those phenomena as a function of temperature and wavelength. The test of equipment and its functionality were carried out step by step (apparatus, components and control sample) and associated with the calculation of the main physical parameters. The tests of individual parts of the apparatus clearly confirmed that the design, construction and selected components fulfil or even exceed the required properties. On the basis of the measurement of selected sample, it was shown that even weak signals from the material can be detected from both thermally stimulated luminescence and thermally stimulated exo-electron emission moreover transmission and desorption can be measured. NaCl:Ni (0.2%) was chosen as the test material. The activation energies and frequency factor were calculated using the methods of different authors.
Ultrasonic inspection and deployment apparatus
Michaels, Jennifer E.; Michaels, Thomas E.; Mech, Jr., Stephen J.
1984-01-01
An ultrasonic inspection apparatus for the inspection of metal structures, especially installed pipes. The apparatus combines a specimen inspection element, an acoustical velocity sensing element, and a surface profiling element, all in one scanning head. A scanning head bellows contains a volume of oil above the pipe surface, serving as acoustical couplant between the scanning head and the pipe. The scanning head is mounted on a scanning truck which is mobile around a circular track surrounding the pipe. The scanning truck has sufficient motors, gears, and position encoders to allow the scanning head six degrees of motion freedom. A computer system continually monitors acoustical velocity, and uses that parameter to process surface profiling and inspection data. The profiling data is used to automatically control scanning head position and alignment and to define a coordinate system used to identify and interpret inspection data. The apparatus is suitable for highly automated, remote application in hostile environments, particularly high temperature and radiation areas.
Methods and systems for integrating fluid dispensing technology with stereolithography
Medina, Francisco; Wicker, Ryan; Palmer, Jeremy A.; Davis, Don W.; Chavez, Bart D.; Gallegos, Phillip L.
2010-02-09
An integrated system and method of integrating fluid dispensing technologies (e.g., direct-write (DW)) with rapid prototyping (RP) technologies (e.g., stereolithography (SL)) without part registration comprising: an SL apparatus and a fluid dispensing apparatus further comprising a translation mechanism adapted to translate the fluid dispensing apparatus along the Z-, Y- and Z-axes. The fluid dispensing apparatus comprises: a pressurized fluid container; a valve mechanism adapted to control the flow of fluid from the pressurized fluid container; and a dispensing nozzle adapted to deposit the fluid in a desired location. To aid in calibration, the integrated system includes a laser sensor and a mechanical switch. The method further comprises building a second part layer on top of the fluid deposits and optionally accommodating multi-layered circuitry by incorporating a connector trace. Thus, the present invention is capable of efficiently building single and multi-material SL fabricated parts embedded with complex three-dimensional circuitry using DW.
Apparatus for electroplating particles of small dimension
Yu, C.M.; Illige, J.D.
1980-09-19
The thickness, uniformity, and surface smoothness requirements for surface coatings of glass microspheres for use as targets for laser fusion research are critical. Because of thier minute size, the microspheres are difficult to manipulate and control in electroplating systems. The electroplating apparatus of the present invention addresses these problems by providing a cathode cell having a cell chamber, a cathode and an anode electrically isolated from each other and connected to an electrical power source. During the plating process, the cathode is controllably vibrated along with solution pulse to maintain the particles in random free motion so as to attain the desired properties.
Method and apparatus for making diamond-like carbon films
Pern, Fu-Jann [Golden, CO; Touryan, Kenell J [Indian Hills, CO; Panosyan, Zhozef Retevos [Yerevan, AM; Gippius, Aleksey Alekseyevich [Moscow, RU
2008-12-02
Ion-assisted plasma enhanced deposition of diamond-like carbon (DLC) films on the surface of photovoltaic solar cells is accomplished with a method and apparatus for controlling ion energy. The quality of DLC layers is fine-tuned by a properly biased system of special electrodes and by exact control of the feed gas mixture compositions. Uniform (with degree of non-uniformity of optical parameters less than 5%) large area (more than 110 cm.sup.2) DLC films with optical parameters varied within the given range and with stability against harmful effects of the environment are achieved.
Method And Apparatus For Evaluatin Of High Temperature Superconductors
Fishman, Ilya M.; Kino, Gordon S.
1996-11-12
A technique for evaluation of high-T.sub.c superconducting films and single crystals is based on measurement of temperature dependence of differential optical reflectivity of high-T.sub.c materials. In the claimed method, specific parameters of the superconducting transition such as the critical temperature, anisotropy of the differential optical reflectivity response, and the part of the optical losses related to sample quality are measured. The apparatus for performing this technique includes pump and probe sources, cooling means for sweeping sample temperature across the critical temperature and polarization controller for controlling a state of polarization of a probe light beam.
Method and apparatus to selectively reduce NO.sub.x in an exhaust gas feedstream
Schmieg, Steven J [Troy, MI; Blint, Richard J [Shelby Township, MI; Den, Ling [Sterling Heights, MI; Viola, Michael B [Macomb Township, MI; Lee, Jong-Hwan [Rochester Hills, MI
2011-08-30
A method and apparatus are described to selectively reduce NO.sub.x emissions of an internal combustion engine. An exhaust aftertreatment system includes an injection device operative to dispense a hydrocarbon reductant upstream of a silver-alumina catalytic reactor device. A control system determines a NO.sub.x concentration and hydrocarbon/NOx ratio based upon selected parameters of the exhaust gas feedstream and dispenses hydrocarbon reductant during lean engine operation. Included is a method to control elements of the feedstream during lean operation. The hydrocarbon reductant may include engine fuel.
Method and apparatus for off-gas composition sensing
Ottesen, David Keith; Allendorf, Sarah Williams; Hubbard, Gary Lee; Rosenberg, David Ezechiel
1999-01-01
An apparatus and method for non-intrusive collection of off-gas data in a steelmaking furnace includes structure and steps for transmitting a laser beam through the off-gas produced by a steelmaking furnace, for controlling the transmitting to repeatedly scan the laser beam through a plurality of wavelengths in its tuning range, and for detecting the laser beam transmitted through the off-gas and converting the detected laser beam to an electrical signal. The electrical signal is processed to determine characteristics of the off-gas that are used to analyze and/or control the steelmaking process.
Engine speed control apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishii, M.; Miyazaki, M.; Nakamura, N.
1986-11-04
This patent describes an engine speed control apparatus. The system comprises an actuator for adjusting an engine speed, a first unit for computing a desired engine speed, a second unit for detecting the actual engine speed, and a third unit for detecting the difference between the outputs of the first and second units. The system also includes a fourth unit for computing a control pulse width for the actuator in accordance with the output of the third unit, a fifth unit for generating a control signal, a sixth unit for driving the actuator in response to the output of themore » fifth unit, and a seventh unit for computing an optimal halt time to interrupt the driving of the actuator. The actuator is driven intermittently in conformity in the control pulse width and the halt time.« less
MacNeille, S.M.
1958-12-01
Control systems for automatic positioning of an electric motor operated vapor valve are described which is operable under the severe conditions existing in apparatus for electro-magnetlcally separating isotopes. In general, the system includes a rotor for turning the valve comprising two colls mounted mutually perpendicular to each other and also perpendicular to the magnetic field of the isotope separating apparatus. The coils are furnished with both a-c and d- c current by assoclate control circuitry and a position control is provided for varying the ratlo of the a-c currents in the coils and at the same time, but in an inverse manner, the ratio between the d-c currents in the coils is varied. With the present system the magnitude of the motor torque is constant for all valves of the rotor orientatlon angle.
Variable Camber Continuous Aerodynamic Control Surfaces and Methods for Active Wing Shaping Control
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T. (Inventor)
2016-01-01
An aerodynamic control apparatus for an air vehicle improves various aerodynamic performance metrics by employing multiple spanwise flap segments that jointly form a continuous or a piecewise continuous trailing edge to minimize drag induced by lift or vortices. At least one of the multiple spanwise flap segments includes a variable camber flap subsystem having multiple chordwise flap segments that may be independently actuated. Some embodiments also employ a continuous leading edge slat system that includes multiple spanwise slat segments, each of which has one or more chordwise slat segment. A method and an apparatus for implementing active control of a wing shape are also described and include the determination of desired lift distribution to determine the improved aerodynamic deflection of the wings. Flap deflections are determined and control signals are generated to actively control the wing shape to approximate the desired deflection.
Dynamically limiting energy consumed by cooling apparatus
Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.
2015-05-26
Cooling apparatuses and methods are provided which include one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is coupled to the N controllable components, and dynamically adjusts operation of the N controllable components, based on Z input parameters and one or more specified constraints, to provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.
Design of a force reflecting hand controller for space telemanipulation studies
NASA Technical Reports Server (NTRS)
Paines, J. D. B.
1987-01-01
The potential importance of space telemanipulator systems is reviewed, along with past studies of master-slave manipulation using a generalized force reflecting master arm. Problems concerning their dynamic interaction with the human operator have been revealed in the use of these systems, with marked differences between 1-g and simulated weightless conditions. A study is outlined to investigate the optimization of the man machine dynamics of master-slave manipulation, and a set of specifications is determined for the apparatus necessary to perform this investigation. This apparatus is a one degree of freedom force reflecting hand controller with closed loop servo control which enables it to simulate arbitrary dynamic properties to high bandwidth. Design of the complete system and its performance is discussed. Finally, the experimental adjustment of the hand controller dynamics for smooth manual control performance with good operator force perception is described, resulting in low inertia, viscously damped hand controller dynamics.
Colacino, Francesco Maria; Moscato, Francesco; Piedimonte, Fabio; Danieli, Guido; Nicosia, Salvatore; Arabia, Maurizio
2008-01-01
This article describes an elastance-based mock ventricle able to reproduce the correct ventricular pressure-volume relationship and its correct interaction with the hydraulic circuit connected to it. A real-time control of the mock ventricle was obtained by a new left ventricular mathematical model including resistive and inductive terms added to the classical Suga-Sagawa elastance model throughout the whole cardiac cycle. A valved piston pump was used to mimic the left ventricle. The pressure measured into the pump chamber was fed back into the mathematical model and the calculated reference left ventricular volume was used to drive the piston. Results show that the classical model is very sensitive to pressure disturbances, especially during the filling phase, while the modified model is able to filter out the oscillations thus eliminating their detrimental effects. The presented model is thus suitable to control mock ventricles in real-time, where sudden pressure disturbances represent a key issue and are not negligible. This real-time controlled mock ventricle is able to reproduce the elastance mechanism of a natural ventricle by mimicking its preload (mean atrial pressure) and afterload (mean aortic pressure) sensitivity, i.e., the Starling law. Therefore, it can be used for designing and testing cardiovascular prostheses due to its capability to reproduce the correct ventricle-vascular system interaction.
Material forming apparatus using a directed droplet stream
Holcomb, David E.; Viswanathan, Srinath; Blue, Craig A.; Wilgen, John B.
2000-01-01
Systems and methods are described for rapidly forming precision metallic and intermetallic alloy net shape parts directly from liquid metal droplets. A directed droplet deposition apparatus includes a crucible with an orifice for producing a jet of material, a jet destabilizer, a charging structure, a deflector system, and an impact zone. The systems and methods provide advantages in that fully dense, microstructurally controlled parts can be fabricated at moderate cost.
Pulsed source ion implantation apparatus and method
Leung, K.N.
1996-09-24
A new pulsed plasma-immersion ion-implantation apparatus that implants ions in large irregularly shaped objects to controllable depth without overheating the target, minimizing voltage breakdown, and using a constant electrical bias applied to the target. Instead of pulsing the voltage applied to the target, the plasma source, for example a tungsten filament or a RF antenna, is pulsed. Both electrically conducting and insulating targets can be implanted. 16 figs.
Apparatus Tests Peeling Of Bonded Rubbery Material
NASA Technical Reports Server (NTRS)
Crook, Russell A.; Graham, Robert
1996-01-01
Instrumented hydraulic constrained blister-peel apparatus obtains data on degree of bonding between specimen of rubbery material and rigid plate. Growth of blister tracked by video camera, digital clock, pressure transducer, and piston-displacement sensor. Cylinder pressure controlled by hydraulic actuator system. Linear variable-differential transformer (LVDT) and float provide second, independent measure of change in blister volume used as more precise volume feedback in low-growth-rate test.
Combustion products generating and metering device
NASA Technical Reports Server (NTRS)
Wiberg, R. E.; Klisch, J. A. (Inventor)
1971-01-01
An apparatus for generating combustion products at a predetermined fixed rate, mixing the combustion products with air to achieve a given concentration, and distributing the resultant mixture to an area or device to be tested is described. The apparatus is comprised of blowers, a holder for the combustion product generating materials (which burn at a predictable and controlled rate), a mixing plenum chamber, and a means for distributing the air combustion product mixture.
Gallegos-Lopez, Gabriel
2012-10-02
Methods, system and apparatus are provided for increasing voltage utilization in a five-phase vector controlled machine drive system that employs third harmonic current injection to increase torque and power output by a five-phase machine. To do so, a fundamental current angle of a fundamental current vector is optimized for each particular torque-speed of operating point of the five-phase machine.
A new confined high pressure rotary shear apparatus: preliminary results
NASA Astrophysics Data System (ADS)
Faulkner, D.; Coughlan, G.; Bedford, J. D.
2017-12-01
The frictional properties of fault zone materials, and their evolution during slip, are of paramount importance for determining the earthquake mechanics of large tectonic faults. Friction is a parameter that is difficult to determine from seismological methods so much of our understanding comes from experiment. Rotary shear apparatuses have been widely used in experimental studies to elucidate the frictional properties of faults under realistic earthquake slip velocities (0.1-10 m/s) and displacements (>20 m). However one technical limitation of rotary shear experiments at seismic slip rates has been the lack of confinement. This has led to a limit on the normal stress (due to the strength of the forcing blocks) and also a lack of control of measurements of the pore fluid pressure. Here we present the first preliminary results from a rotary shear apparatus that has been developed to attempt to address this issue. The new fully confined ring shear apparatus has a fast-acting servo-hydraulic confining pressure system of up to 200 MPa and a servo-controlled upstream and downstream pore pressure system of up to 200 MPa. Displacement rates of 0.01μ/s to 2 m/s can be achieved. Fault gouge samples can therefore be sheared at earthquake speed whilst being subject to pressures typically associated with the depth of earthquake nucleation.
Application of ASTM E-1559 Apparatus to Study H2O Desorption
NASA Technical Reports Server (NTRS)
Woronowicz, Michael; Perry, Radford, III; Meadows, George A.
2015-01-01
The NASA James Webb Space Telescope project identified a need to measure water vapor desorption from cryogenic surfaces in order to validate predictions of spacecraft design performance. A review of available scientific literature indicated no such measurements had been reported below 131 K. Contamination control personnel at NASA Goddard Space Flight Center recognized the possibility they readily possessed the means to collect these measurements at lower temperatures using an existing apparatus commonly employed for making outgassing observations. This presentation will relate how the ASTM E-1559 Molekit apparatus was used without physical modification to measure water vapor sublimation down to 120 K and compare this data to existing equilibrium vapor pressure models.
The Preliminary Evaluation of Liquid Lubricants for Space Applications by Vacuum Tribometry
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Pepper, S. V.; Herrera-Fierro, P.; Feuchter, D.; Toddy, T. J.; Jayne, D. T.; Wheeler, D. R.; Abel, P. B.; Kingsbury, E.; Morales, W.
1994-01-01
Four different vacuum tribometers for the evaluation of liquid lubricants for space applications are described. These range from simple ball-on-flat sliders with maximum in-situ control and surface characterization to an instrument bearing apparatus having no in-situ characterization. Thus, the former provides an abundance of surface chemical information but is not particularly simulative of most triboelements. On the other hand, the instrument bearing apparatus is completely simulative, but only allows post-mortem surface chemical information. Two other devices, a four-ball apparatus and a ball-on-plate tribometer, provide varying degrees of surface chemical information and tribo-simulation. Examples of data from each device are presented.
APPARATUS FOR CONDENSATION AND SUBLIMATION
Schmidt, R.J.; Fuis, F. Jr.
1958-10-01
An apparatus is presented for the sublimation and condensation of uranium compounds in order to obtain an improved crystalline structure of this material. The apparatus comprises a vaporizing chamber and condensing structure connected thereto. There condenser is fitted with a removable liner having a demountable baffle attached to the liner by means of brackets and a removable pin. The baffle is of spiral cross-section and is provided with cooling coils disposed between the surfaces of the baffle for circulation of a temperature controlling liquid within the baffle. The cooling coll provides for controlllng the temperature of the baffle to insure formatlon of a satisfactory condensate, and the removable liner facilitates the removal of condensate formed during tbe sublimation process.
A single-sweep, nanosecond time resolution laser temperature-jump apparatus
NASA Astrophysics Data System (ADS)
Ballew, R. M.; Sabelko, J.; Reiner, C.; Gruebele, M.
1996-10-01
We describe a fast temperature-jump (T-jump) apparatus capable of acquiring kinetic relaxation transients via real-time fluorescence detection over a time interval from nanoseconds to milliseconds in a single sweep. The method is suitable for aqueous solutions, relying upon the direct absorption of laser light by the bulk water. This obviates the need for additives (serving as optical or conductive heaters) that may interact with the sample under investigation. The longitudinal temperature profile is made uniform by counterpropagating heating pulses. Dead time is limited to one period of the probe laser (16 ns). The apparatus response is tested with aqueous tryptophan and the diffusion-controlled dimerization of proflavine.
Gomez, Antonio; DeRego, Paul Jeffrey; Ferrell, Patrick Andrew; Thom, Robert Anthony; Trujillo, Joshua J.; Herridge, Brian
2015-09-29
An apparatus for generating seismic waves includes a housing, a strike surface within the housing, and a hammer movably disposed within the housing. An actuator induces a striking motion in the hammer such that the hammer impacts the strike surface as part of the striking motion. The actuator is selectively adjustable to change characteristics of the striking motion and characteristics of seismic waves generated by the impact. The hammer may be modified to change the physical characteristics of the hammer, thereby changing characteristics of seismic waves generated by the hammer. The hammer may be disposed within a removable shock cavity, and the apparatus may include two hammers and two shock cavities positioned symmetrically about a center of the apparatus.
Gomez, Antonio; DeRego, Paul Jeffrey; Ferrel, Patrick Andrew; Thom, Robert Anthony; Trujillo, Joshua J.; Herridge, Brian
2014-08-19
An apparatus for generating seismic waves includes a housing, a strike surface within the housing, and a hammer movably disposed within the housing. An actuator induces a striking motion in the hammer such that the hammer impacts the strike surface as part of the striking motion. The actuator is selectively adjustable to change characteristics of the striking motion and characteristics of seismic waves generated by the impact. The hammer may be modified to change the physical characteristics of the hammer, thereby changing characteristics of seismic waves generated by the hammer. The hammer may be disposed within a removable shock cavity, and the apparatus may include two hammers and two shock cavities positioned symmetrically about a center of the apparatus.
Microscope collision protection apparatus
DeNure, Charles R.
2001-10-23
A microscope collision protection apparatus for a remote control microscope which protects the optical and associated components from damage in the event of an uncontrolled collision with a specimen, regardless of the specimen size or shape. In a preferred embodiment, the apparatus includes a counterbalanced slide for mounting the microscope's optical components. This slide replaces the rigid mounts on conventional upright microscopes with a precision ball bearing slide. As the specimen contacts an optical component, the contacting force will move the slide and the optical components mounted thereon. This movement will protect the optical and associated components from damage as the movement causes a limit switch to be actuated, thereby stopping all motors responsible for the collision.
Gram staining apparatus for space station applications.
Molina, T C; Brown, H D; Irbe, R M; Pierson, D L
1990-01-01
A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space. Images PMID:1690529
Sample preparation system for microfluidic applications
Mosier, Bruce P [San Francisco, CA; Crocker, Robert W [Fremont, CA; Patel, Kamlesh D [Dublin, CA; Harnett, Cindy K [Livermore, CA
2007-05-08
An apparatus that couples automated injection with flow feedback to provide nanoliter accuracy in controlling microliter volumes. The apparatus comprises generally a source of hydraulic fluid pressure, a fluid isolator joined to the outlet of the hydraulic pressure source and a flow sensor to provide pressure-driven analyte metering. For operation generally and particularly in microfluidic systems the hydraulic pressure source is typically an electrokinetic (EK) pump that incorporates gasless electrodes. The apparatus is capable of metering sub-microliter volumes at flowrates of 1 100 .mu.L/min into microsystem load pressures of up to 1000 50 psi, respectively. Flowrates can be specified within 0.5 .mu.L/min and volumes as small as 80 nL can be metered.
Staib, Jessica L; Quindry, John C; French, Joel P; Criswell, David S; Powers, Scott K
2007-01-01
The expression of myocardial heat shock protein 72 (HSP72) postexercise is initiated by the activation of heat shock transcription factor 1 (HSF1). However, it remains unknown which physiological stimuli govern myocardial HSF1 activation during exercise. These experiments tested the hypothesis that thermal stress and mechanical load, concomitant with simulated exercise, provide independent stimuli for HSF1 activation and ensuing cardiac HSP72 gene expression. To elucidate the independent roles of increased temperature and cardiac workload in the exercise-mediated upregulation of left-ventricular HSP72, hearts from adult male Sprague-Dawley rats were randomly assigned to one of five simulated exercise conditions. Upon reaching a surgical plane of anesthesia, each experimental heart was isolated and perfused using an in vitro working heart model, while independently varying temperatures (i.e., 37 degrees C vs. 40 degrees C) and cardiac workloads (i.e., low preload and afterload vs. high preload and afterload) to mimic exercise responses. Results indicate that hyperthermia, independent of cardiac workload, promoted an increase in nuclear translocation and phosphorylation of HSF1 compared with normothermic left ventricles. Similarly, hyperthermia, independent of workload, resulted in significant increases in cardiac levels of HSP72 mRNA. Collectively, these data suggest that HSF1 activation and HSP72 gene transcriptional competence during simulated exercise are linked to elevated heart temperature and are not a direct function of increased cardiac workload.
Alghanem, Fares; Bryner, Benjamin S; Jahangir, Emilia M; Fernando, Uditha P; Trahanas, John M; Hoffman, Hayley R; Bartlett, Robert H; Rojas-Peña, Alvaro; Hirschl, Ronald B
Lung disease in children often results in pulmonary hypertension and right heart failure. The availability of a pediatric artificial lung (PAL) would open new approaches to the management of these conditions by bridging to recovery in acute disease or transplantation in chronic disease. This study investigates the efficacy of a novel PAL in alleviating an animal model of pulmonary hypertension and increased right ventricle afterload. Five juvenile lambs (20-30 kg) underwent PAL implantation in a pulmonary artery to left atrium configuration. Induction of disease involved temporary, reversible occlusion of the right main pulmonary artery. Hemodynamics, pulmonary vascular input impedance, and right ventricle efficiency were measured under 1) baseline, 2) disease, and 3) disease + PAL conditions. The disease model altered hemodynamics variables in a manner consistent with pulmonary hypertension. Subsequent PAL attachment improved pulmonary artery pressure (p = 0.018), cardiac output (p = 0.050), pulmonary vascular input impedance (Z.0 p = 0.028; Z.1 p = 0.058), and right ventricle efficiency (p = 0.001). The PAL averaged resistance of 2.3 ± 0.8 mm Hg/L/min and blood flow of 1.3 ± 0.6 L/min. This novel low-resistance PAL can alleviate pulmonary hypertension in an acute animal model and demonstrates potential for use as a bridge to lung recovery or transplantation in pediatric patients with significant pulmonary hypertension refractory to medical therapies.