Sample records for controlled double masked

  1. Automatic alternative phase-shift mask CAD layout tool for gate shrinkage of embedded DRAM in logic below 0.18 μm

    NASA Astrophysics Data System (ADS)

    Ohnuma, Hidetoshi; Kawahira, Hiroichi

    1998-09-01

    An automatic alternative phase shift mask (PSM) pattern layout tool has been newly developed. This tool is dedicated for embedded DRAM in logic device to shrink gate line width with improving line width controllability in lithography process with a design rule below 0.18 micrometers by the KrF excimer laser exposure. The tool can crete Levenson type PSM used being coupled with a binary mask adopting a double exposure method for positive photo resist. By using graphs, this tool automatically creates alternative PSM patterns. Moreover, it does not give any phase conflicts. By adopting it to actual embedded DRAM in logic cells, we have provided 0.16 micrometers gate resist patterns at both random logic and DRAM areas. The patterns were fabricated using two masks with the double exposure method. Gate line width has been well controlled under a practical exposure-focus window.

  2. Process variation challenges and resolution in the negative-tone develop double patterning for 20nm and below technology node

    NASA Astrophysics Data System (ADS)

    Mehta, Sohan S.; Ganta, Lakshmi K.; Chauhan, Vikrant; Wu, Yixu; Singh, Sunil; Ann, Chia; Subramany, Lokesh; Higgins, Craig; Erenturk, Burcin; Srivastava, Ravi; Singh, Paramjit; Koh, Hui Peng; Cho, David

    2015-03-01

    Immersion based 20nm technology node and below becoming very challenging to chip designers, process and integration due to multiple patterning to integrate one design layer . Negative tone development (NTD) processes have been well accepted by industry experts for enabling technologies 20 nm and below. 193i double patterning is the technology solution for pitch down to 80 nm. This imposes tight control in critical dimension(CD) variation in double patterning where design patterns are decomposed in two different masks such as in litho-etch-litho etch (LELE). CD bimodality has been widely studied in LELE double patterning. A portion of CD tolerance budget is significantly consumed by variations in CD in double patterning. The objective of this work is to study the process variation challenges and resolution in the Negative Tone Develop Process for 20 nm and Below Technology Node. This paper describes the effect of dose slope on CD variation in negative tone develop LELE process. This effect becomes even more challenging with standalone NTD developer process due to q-time driven CD variation. We studied impact of different stacks with combination of binary and attenuated phase shift mask and estimated dose slope contribution individually from stack and mask type. Mask 3D simulation was carried out to understand theoretical aspect. In order to meet the minimum insulator requirement for the worst case on wafer the overlay and critical dimension uniformity (CDU) budget margins have slimmed. Besides the litho process and tool control using enhanced metrology feedback, the variation control has other dependencies too. Color balancing between the two masks in LELE is helpful in countering effects such as iso-dense bias, and pattern shifting. Dummy insertion and the improved decomposition techniques [2] using multiple lower priority constraints can help to a great extent. Innovative color aware routing techniques [3] can also help with achieving more uniform density and color balanced layouts.

  3. Layout decomposition of self-aligned double patterning for 2D random logic patterning

    NASA Astrophysics Data System (ADS)

    Ban, Yongchan; Miloslavsky, Alex; Lucas, Kevin; Choi, Soo-Han; Park, Chul-Hong; Pan, David Z.

    2011-04-01

    Self-aligned double pattering (SADP) has been adapted as a promising solution for sub-30nm technology nodes due to its lower overlay problem and better process tolerance. SADP is in production use for 1D dense patterns with good pitch control such as NAND Flash memory applications, but it is still challenging to apply SADP to 2D random logic patterns. The favored type of SADP for complex logic interconnects is a two mask approach using a core mask and a trim mask. In this paper, we first describe layout decomposition methods of spacer-type double patterning lithography, then report a type of SADP compliant layouts, and finally report SADP applications on Samsung 22nm SRAM layout. For SADP decomposition, we propose several SADP-aware layout coloring algorithms and a method of generating lithography-friendly core mask patterns. Experimental results on 22nm node designs show that our proposed layout decomposition for SADP effectively decomposes any given layouts.

  4. 65-nm full-chip implementation using double dipole lithography

    NASA Astrophysics Data System (ADS)

    Hsu, Stephen D.; Chen, J. Fung; Cororan, Noel; Knose, William T.; Van Den Broeke, Douglas J.; Laidig, Thomas L.; Wampler, Kurt E.; Shi, Xuelong; Hsu, Michael; Eurlings, Mark; Finders, Jo; Chiou, Tsann-Bim; Socha, Robert J.; Conley, Will; Hsieh, Yen W.; Tuan, Steve; Hsieh, Frank

    2003-06-01

    Double Dipole Lithography (DDL) has been demonstrated to be capable of patterning complex 2D patterns. Due to inherently high aerial imaging contrast, especially for dense features, we have found that it has a very good potential to meet manufacturing requirements for the 65nm node using ArF binary chrome masks. For patterning in the k1<0.35 regime without resorting to hard phase-shift masks (PSMs), DDL is one unique Resolution Enhancement Technique (RET) which can achieve an acceptable process window. To utilize DDL for printing actual IC devices, the original design data must be decomposed into "vertical (V)" and "horizontal (H)" masks for the respective X- and Y-dipole exposures. An improved two-pass, model-based, DDL mask data processing methodology has been established. It is capable of simultaneously converting complex logic and memory mask patterns into DDL compatible mask layout. To maximize the overlapped process window area, we have previously shown that the pattern-shielding algorithm must be intelligently applied together with both Scattering Bars (SBs) and model-based OPC (MOPC). Due to double exposures, stray light must be well-controlled to ensure uniform printing across the entire chip. One solution to minimize stray light is to apply large patches of solid chrome in open areas to reduce the background transmission during exposure. Unfortunately, this is not feasible for a typical clear-field poly gate masks to be patterned by a positive resist process. In this work, we report a production-worthy DDL mask pattern decomposition scheme for full-chip application. A new generation of DDL technology reticle set has been developed to verify the printing performance. Shielding is a critical part of the DDL. An innovative shielding scheme has been developed to protect the critical features and minimize the impact of stray light during double exposure.

  5. In-die mask registration measurement on 28nm-node and beyond

    NASA Astrophysics Data System (ADS)

    Chen, Shen Hung; Cheng, Yung Feng; Chen, Ming Jui

    2013-09-01

    As semiconductor go to smaller node, the critical dimension (CD) of process become more and more small. For lithography, RET (Resolution Enhancement Technology) applications can be used for wafer printing of smaller CD/pitch on 28nm node and beyond. SMO (Source Mask Optimization), DPT (Double Patterning Technology) and SADP (Self-Align Double Patterning) can provide lower k1 value for lithography. In another way, image placement error and overlay control also become more and more important for smaller chip size (advanced node). Mask registration (image placement error) and mask overlay are important factors to affect wafer overlay control/performance especially for DPT or SADP. In traditional method, the designed registration marks (cross type, square type) with larger CD were put into scribe-line of mask frame for registration and overlay measurement. However, these patterns are far way from real patterns. It does not show the registration of real pattern directly and is not a convincing method. In this study, the in-die (in-chip) registration measurement is introduced. We extract the dummy patterns that are close to main pattern from post-OPC (Optical Proximity Correction) gds by our desired rule and choose the patterns that distribute over whole mask uniformly. The convergence test shows 100 points measurement has a reliable result.

  6. Flavored Anesthetic Masks for Inhalational Induction in Children.

    PubMed

    Gupta, Aakriti; Mathew, Preethy Joseph; Bhardwaj, Neerja

    2017-10-01

    To evaluate the clinical efficacy of masking the odor of inhalational agents using fruit flavors on the anxiety behavior and compliance of children for inhalational induction. A prospective randomized double blind, placebo controlled study was conducted on 60 unpremedicated children in the age group of 4-12 y. Thirty children received anesthetic masks smeared with a flavor of child's choice while the other 30 children were induced using masks without flavor. Anxiety was assessed using modified Yale Pre-operative Anxiety Scale (mYPAS) in the pre-op room and during inhalational induction. Mask acceptance was graded by Induction Compliance Checklist (ICC). The cost-effectiveness of flavored anesthetic masks was compared to that of commercially available pre-scented masks. The baseline anxiety in the two groups was comparable. The number of children demonstrating high levels of anxiety at anesthetic induction was similar in flavored and non-flavored mask groups (p 0.45). The compliance to mask induction was also equally good (p 0.99). The authors found significant difference in the cost of flavored mask (INR 56.45 per mask) as compared to commercially available pre-scented masks (INR 660 per mask). The authors observed a placebo effect that reduced the pre-op anxiety in the control group which probably made the quality of induction equivalent with flavored and non-flavored masks. Therefore, using a flavored anesthetic mask is cost-effective than using a commercially available pre-scented mask.

  7. Evoked-potential recovery during double click stimulation in a beluga whale: implications for biosonar gain control.

    PubMed

    Supin, Alexander Ya; Popov, Vladimir V

    2015-05-01

    Auditory evoked potentials (AEPs) were recorded in a beluga whale Delphinapterus leucas using a double-pulse stimulation paradigm, specifically measuring the recovery (release from masking) of the second (test) response as a function of delay after the first (conditioning) pulse at various levels of the conditioning and test stimuli. The conditioning/test stimulus level ratio influenced the recovery time (the higher the ratio, the longer the recovery). This interrelation was used to evaluate the intensity/time trade in release from forward masking. Trade was evaluated as 32.2 dB per time decade. Data were considered as simulating interactions between the transmitted pulse and echo during echolocation, assuming that a transmitted sonar pulse produces forward masking of the echo response. With increased target distance, the attenuation of the echo may be compensated by the release from masking. According to the model, the compensation results in substantial stabilization of the echo response even if the intensity/time trade of release from masking is not precisely equal to the rate of echo attenuation with distance.

  8. Microfluidic approach for encapsulation via double emulsions.

    PubMed

    Wang, Wei; Zhang, Mao-Jie; Chu, Liang-Yin

    2014-10-01

    Double emulsions, with inner drops well protected by the outer shells, show great potential as compartmentalized systems to encapsulate multiple components for protecting actives, masking flavor, and targetedly delivering and controllably releasing drugs. Precise control of the encapsulation characteristics of each component is critical to achieve an optimal therapeutic efficacy for pharmaceutical applications. Such controllable encapsulation can be realized by using microfluidic approaches for producing monodisperse double emulsions with versatile and controllable structures as the encapsulation system. The size, number and composition of the emulsion drops can be accurately manipulated for optimizing the encapsulation of each component for pharmaceutical applications. In this review, we highlight the outstanding advantages of controllable microfluidic double emulsions for highly efficient and precisely controllable encapsulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Design architecture of double spiral interdigitated electrode with back gate electrode for biosensor application

    NASA Astrophysics Data System (ADS)

    Fathil, M. F. M.; Arshad, M. K. Md.; Hashim, U.; Ruslinda, A. R.; Gopinath, Subash C. B.; M. Nuzaihan M., N.; Ayub, R. M.; Adzhri, R.; Zaki, M.; Azman, A. H.

    2016-07-01

    This paper presents the preparation method of photolithography chrome mask design used in fabrication process of double spiral interdigitated electrode with back gate biasing based biosensor. By learning the fabrication process flow of the biosensor, the chrome masks are designed through drawing using the AutoCAD software. The overall width and length of the device is optimized at 7.0 mm and 10.0 mm, respectively. Fabrication processes of the biosensor required three chrome masks, which included back gate opening, spiral IDE formation, and passivation area formation. The complete chrome masks design will be sent for chrome mask fabrication and for future use in biosensor fabrication.

  10. Variability-aware double-patterning layout optimization for analog circuits

    NASA Astrophysics Data System (ADS)

    Li, Yongfu; Perez, Valerio; Tripathi, Vikas; Lee, Zhao Chuan; Tseng, I.-Lun; Ong, Jonathan Yoong Seang

    2018-03-01

    The semiconductor industry has adopted multi-patterning techniques to manage the delay in the extreme ultraviolet lithography technology. During the design process of double-patterning lithography layout masks, two polygons are assigned to different masks if their spacing is less than the minimum printable spacing. With these additional design constraints, it is very difficult to find experienced layout-design engineers who have a good understanding of the circuit to manually optimize the mask layers in order to minimize color-induced circuit variations. In this work, we investigate the impact of double-patterning lithography on analog circuits and provide quantitative analysis for our designers to select the optimal mask to minimize the circuit's mismatch. To overcome the problem and improve the turn-around time, we proposed our smart "anchoring" placement technique to optimize mask decomposition for analog circuits. We have developed a software prototype that is capable of providing anchoring markers in the layout, allowing industry standard tools to perform automated color decomposition process.

  11. Double exposure using 193nm negative tone photoresist

    NASA Astrophysics Data System (ADS)

    Kim, Ryoung-han; Wallow, Tom; Kye, Jongwook; Levinson, Harry J.; White, Dave

    2007-03-01

    Double exposure is one of the promising methods for extending lithographic patterning into the low k I regime. In this paper, we demonstrate double patterning of k 1-effective=0.25 with improved process window using a negative resist. Negative resist (TOK N- series) in combination with a bright field mask is proven to provide a large process window in generating 1:3 = trench:line resist features. By incorporating two etch transfer steps into the hard mask material, frequency doubled patterns could be obtained.

  12. In-die photomask registration and overlay metrology with PROVE using 2D correlation methods

    NASA Astrophysics Data System (ADS)

    Seidel, D.; Arnz, M.; Beyer, D.

    2011-11-01

    According to the ITRS roadmap, semiconductor industry drives the 193nm lithography to its limits, using techniques like double exposure, double patterning, mask-source optimization and inverse lithography. For photomask metrology this translates to full in-die measurement capability for registration and critical dimension together with challenging specifications for repeatability and accuracy. Especially, overlay becomes more and more critical and must be ensured on every die. For this, Carl Zeiss SMS has developed the next generation photomask registration and overlay metrology tool PROVE® which serves the 32nm node and below and which is already well established in the market. PROVE® features highly stable hardware components for the stage and environmental control. To ensure in-die measurement capability, sophisticated image analysis methods based on 2D correlations have been developed. In this paper we demonstrate the in-die capability of PROVE® and present corresponding measurement results for shortterm and long-term measurements as well as the attainable accuracy for feature sizes down to 85nm using different illumination modes and mask types. Standard measurement methods based on threshold criteria are compared with the new 2D correlation methods to demonstrate the performance gain of the latter. In addition, mask-to-mask overlay results of typical box-in-frame structures down to 200nm feature size are presented. It is shown, that from overlay measurements a reproducibility budget can be derived that takes into account stage, image analysis and global effects like mask loading and environmental control. The parts of the budget are quantified from measurement results to identify critical error contributions and to focus on the corresponding improvement strategies.

  13. The lithographer's dilemma: shrinking without breaking the bank

    NASA Astrophysics Data System (ADS)

    Levinson, Harry J.

    2013-10-01

    It can no longer be assumed that the lithographic scaling which has previously driven Moore's Law will lead in the future to reduced cost per transistor. Until recently, higher prices for lithography tools were offset by improvements in scanner productivity. The necessity of using double patterning to extend scaling beyond the single exposure resolution limit of optical lithography has resulted in a sharp increase in the cost of patterning a critical construction layer that has not been offset by improvements in exposure tool productivity. Double patterning has also substantially increased the cost of mask sets. EUV lithography represents a single patterning option, but the combination of very high exposure tools prices, moderate throughput, high maintenance costs, and expensive mask blanks makes this a solution more expensive than optical double patterning but less expensive than triple patterning. Directed self-assembly (DSA) could potentially improve wafer costs, but this technology currently is immature. There are also design layout and process integration issues associated with DSA that need to be solved in order to obtain full benefit from tighter pitches. There are many approaches for improving the cost effectiveness of lithography. Innovative double patterning schemes lead to smaller die. EUV lithography productivity can be improved with higher power light sources and improved reliability. There are many technical and business challenges for extending EUV lithography to higher numerical apertures. Efficient contact hole and cut mask solutions are needed, as well as very tight overlay control, regardless of lithographic solution.

  14. Clinical trial of lutein in patients with retinitis pigmentosa receiving vitamin A treatment

    USDA-ARS?s Scientific Manuscript database

    We sought to determine whether lutein supplementation will slow visual function decline in patients with retinitis pigmentosa receiving vitamin A. DESIGN: Randomized, controlled, double-masked trial of 225 nonsmoking patients, aged 18 to 60 years, evaluated over a 4-year interval. Patients received ...

  15. 100-nm gate lithography for double-gate transistors

    NASA Astrophysics Data System (ADS)

    Krasnoperova, Azalia A.; Zhang, Ying; Babich, Inna V.; Treichler, John; Yoon, Jung H.; Guarini, Kathryn; Solomon, Paul M.

    2001-09-01

    The double gate field effect transistor (FET) is an exploratory device that promises certain performance advantages compared to traditional CMOS FETs. It can be scaled down further than the traditional devices because of the greater electrostatic control by the gates on the channel (about twice as short a channel length for the same gate oxide thickness), has steeper sub-threshold slope and about double the current for the same width. This paper presents lithographic results for double gate FET's developed at IBM's T. J. Watson Research Center. The device is built on bonded wafers with top and bottom gates self-aligned to each other. The channel is sandwiched between the top and bottom polysilicon gates and the gate length is defined using DUV lithography. An alternating phase shift mask was used to pattern gates with critical dimensions of 75 nm, 100 nm and 125 nm in photoresist. 50 nm gates in photoresist have also been patterned by 20% over-exposure of nominal 100 nm lines. No trim mask was needed because of a specific way the device was laid out. UV110 photoresist from Shipley on AR-3 antireflective layer were used. Process windows, developed and etched patterns are presented.

  16. Relationship of extinction to perceptual thresholds for single stimuli.

    PubMed

    Meador, K J; Ray, P G; Day, L J; Loring, D W

    2001-04-24

    To demonstrate the effects of target stimulus intensity on extinction to double simultaneous stimuli. Attentional deficits contribute to extinction in patients with brain lesions, but extinction (i.e., masking) can also be produced in healthy subjects. The relationship of extinction to perceptual thresholds for single stimuli remains uncertain. Brief electrical pulses were applied simultaneously to the left and right index fingers of 16 healthy volunteers (8 young and 8 elderly adults) and 4 patients with right brain stroke (RBS). The stimulus to be perceived (i.e., target stimulus) was given at the lowest perceptual threshold to perceive any single stimulus (i.e., Minimal) and at the threshold to perceive 100% of single stimuli. The mask stimulus (i.e., stimulus given to block the target) was applied to the contralateral hand at intensities just below discomfort. Extinction was less for target stimuli at 100% than Minimal threshold for healthy subjects. Extinction of left targets was greater in patients with RBS than elderly control subjects. Left targets were extinguished less than right in healthy subjects. In contrast, the majority of left targets were extinguished in patients with RBS even when right mask intensity was reduced below right 100% threshold for single stimuli. RBS patients had less extinction for right targets despite having greater left mask - threshold difference than control subjects. In patients with RBS, right "targets" at 100% threshold extinguished left "masks" (20%) almost as frequently as left masks extinguished right targets (32%). Subtle changes in target intensity affect extinction in healthy adults. Asymmetries in mask and target intensities (relative to single-stimulus perceptual thresholds) affect extinction in RBS patients less for left targets but more for right targets as compared with control subjects.

  17. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial.

    PubMed

    Ari, Seyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Caca, Ihsan

    2009-08-01

    The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group (48/50 [96%] vs 42/50 [84%]; P=0.005). Based on nasolacrimal duct irrigation, significantly fewer patients in the MMC group than the control group had an enclosed naso-lacrimal duct (2/50 [4%] vs 8/50 [16%]). No adverse effects (eg, abnormal nasal bleeding, mucosal necrosis, infection) or any other surgical adverse events were observed. In the management of these patients with primary acquired nasolacrimal duct obstruction, adjunctive intraoperative MMC application with standard DCR surgery had a significantly higher success rate than did standard DCR surgery alone. Further large, double-masked, randomized studies are needed to confirm these findings.

  18. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial

    PubMed Central

    Ari, Şeyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Çaca, Îhsan

    2009-01-01

    Background: The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. Objectives: The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). Methods: In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. Results: One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group (48/50 [96%] vs 42/50 [84%]; P=0.005). Based on nasolacrimal duct irrigation, significantly fewer patients in the MMC group than the control group had an enclosed naso-lacrimal duct (2/50 [4%] vs 8/50 [16%]). No adverse effects (eg, abnormal nasal bleeding, mucosal necrosis, infection) or any other surgical adverse events were observed. Conclusions: In the management of these patients with primary acquired nasolacrimal duct obstruction, adjunctive intraoperative MMC application with standard DCR surgery had a significantly higher success rate than did standard DCR surgery alone. Further large, double-masked, randomized studies are needed to confirm these findings. PMID:24683236

  19. Exploring the contributions of the supplementary eye field to subliminal inhibition using double-pulse transcranial magnetic stimulation.

    PubMed

    Chiau, Hui-Yan; Muggleton, Neil G; Juan, Chi-Hung

    2017-01-01

    It is widely accepted that the supplementary eye fields (SEF) are involved in the control of voluntary eye movements. However, recent evidence suggests that SEF may also be important for unconscious and involuntary motor processes. Indeed, Sumner et al. ([2007]: Neuron 54:697-711) showed that patients with micro-lesions of the SEF demonstrated an absence of subliminal inhibition as evoked by masked-prime stimuli. Here, we used double-pulse transcranial magnetic stimulation (TMS) in healthy volunteers to investigate the role of SEF in subliminal priming. We applied double-pulse TMS at two time windows in a masked-prime task: the first during an early phase, 20-70 ms after the onset of the mask but before target presentation, during which subliminal inhibition is present; and the second during a late phase, 20-70 ms after target onset, during which the saccade is being prepared. We found no effect of TMS with the early time window of stimulation, whereas a reduction in the benefit of an incompatible subliminal prime stimulus was found when SEF TMS was applied at the late time window. These findings suggest that there is a role for SEF related to the effects of subliminal primes on eye movements, but the results do not support a role in inhibiting the primed tendency. Hum Brain Mapp 38:339-351, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Molindone and haloperidol in tardive dyskinesia.

    PubMed

    Glazer, W M; Hafez, H M; Benarroche, C L

    1985-08-01

    Preliminary results are described from a study of 11 outpatients manifesting exacerbated tardive dyskinesia after tapering and withdrawal of neuroleptic medications. Patients were randomly assigned to molindone or haloperidol under double-blind placebo-controlled conditions to compare the masking effects of the two drugs. Haloperidol treatment masked withdrawal-exacerbated tardive dyskinesia more than molindone did; this difference (measured by percent change in AIMS scores) was significant (p = .04) when the dose was 200% but not 100% of the prestudy neuroleptic dose. Despite several limitations to the study, the results suggest that molindone may have less dyskinetogenic potential than haloperidol. Further research in the area of site-specificity of molindone is indicated.

  1. NOTE: Calculating diffraction patterns

    NASA Astrophysics Data System (ADS)

    Rioux, Frank

    2003-05-01

    Following Marcella's approach to the double-slit experiment (Marcella T V 2002 Eur. J. Phys. 23 615-21), diffraction patterns for two-dimensional masks are calculated by Fourier transform of the Mask geometry into momentum space.

  2. Overlay improvement by exposure map based mask registration optimization

    NASA Astrophysics Data System (ADS)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density could also achieve under 5nm performance. We assume mask registration excluding random error is mostly induced by charge accumulation during mask writing, which may be calculated from surrounding exposed pattern density. Multi-loading test mask registration result shows that with x direction writing sequence, mask registration behavior in x direction is mainly related to sequence direction, but mask registration in y direction would be highly impacted by pattern density distribution map. It proves part of mask registration error is due to charge issue from nearby environment. If exposure sequence is chip by chip for normal multi chip layout case, mask registration of both x and y direction would be impacted analogously, which has also been proved by real data. Therefore, we try to set up a simple model to predict the mask registration error based on mask exposure map, and correct it with the given POSCOR (position correction) file for advanced mask writing if needed.

  3. Efficacy of a multi micronutrient-fortified drink in improving iron and micronutrient status among schoolchildren with low iron stores in India: A randomised, double-masked placebo-controlled trial

    USDA-ARS?s Scientific Manuscript database

    A multiple micronutrient-fortified drink could be an effective strategy to combating micronutrient deficiencies in school-going children. Our objective was to assess the efficacy of a multiple micronutrient-fortified drink in reducing iron deficiency (ID), ID anemia (IDA), anemia and improving micro...

  4. Model-based assist feature insertion for sub-40nm memory device

    NASA Astrophysics Data System (ADS)

    Suh, Sungsoo; Lee, Suk-joo; Choi, Seong-woon; Lee, Sung-Woo; Park, Chan-hoon

    2009-04-01

    Many issues need to be resolved for a production-worthy model based assist feature insertion flow for single and double exposure patterning process to extend low k1 process at 193 nm immersion technology. Model based assist feature insertion is not trivial to implement either for single and double exposure patterning compared to rule based methods. As shown in Fig. 1, pixel based mask inversion technology in itself has difficulties in mask writing and inspection although it presents as one of key technology to extend single exposure for contact layer. Thus far, inversion technology is tried as a cooptimization of target mask to simultaneously generate optimized main and sub-resolution assists features for a desired process window. Alternatively, its technology can also be used to optimize for a target feature after an assist feature types are inserted in order to simplify the mask complexity. Simplification of inversion mask is one of major issue with applying inversion technology to device development even if a smaller mask feature can be fabricated since the mask writing time is also a major factor. As shown in Figure 2, mask writing time may be a limiting factor in determining whether or not an inversion solution is viable. It can be reasoned that increased number of shot counts relates to increase in margin for inversion methodology. On the other hand, there is a limit on how complex a mask can be in order to be production worthy. There is also source and mask co-optimization which influences the final mask patterns and assist feature sizes and positions for a given target. In this study, we will discuss assist feature insertion methods for sub 40-nm technology.

  5. LENS (lithography enhancement toward nano scale): a European project to support double exposure and double patterning technology development

    NASA Astrophysics Data System (ADS)

    Cantu, Pietro; Baldi, Livio; Piacentini, Paolo; Sytsma, Joost; Le Gratiet, Bertrand; Gaugiran, Stéphanie; Wong, Patrick; Miyashita, Hiroyuki; Atzei, Luisa R.; Buch, Xavier; Verkleij, Dick; Toublan, Olivier; Perez-Murano, Francesco; Mecerreyes, David

    2010-04-01

    In 2009 a new European initiative on Double Patterning and Double Exposure lithography process development was started in the framework of the ENIAC Joint Undertaking. The project, named LENS (Lithography Enhancement Towards Nano Scale), involves twelve companies from five different European Countries (Italy, Netherlands, France, Belgium Spain; includes: IC makers (Numonyx and STMicroelectronics), a group of equipment and materials companies (ASML, Lam Research srl, JSR, FEI), a mask maker (Dai Nippon Photomask Europe), an EDA company (Mentor Graphics) and four research and development institutes (CEA-Leti, IMEC, Centro Nacional de Microelectrónica, CIDETEC). The LENS project aims to develop and integrate the overall infrastructure required to reach patterning resolutions required by 32nm and 22nm technology nodes through the double patterning and pitch doubling technologies on existing conventional immersion exposure tools, with the purpose to allow the timely development of 32nm and 22nm technology nodes for memories and logic devices, providing a safe alternative to EUV, Higher Refraction Index Fluids Immersion Lithography and maskless lithography, which appear to be still far from maturity. The project will cover the whole lithography supply chain including design, masks, materials, exposure tools, process integration, metrology and its final objective is the demonstration of 22nm node patterning on available 1.35 NA immersion tools on high complexity mask set.

  6. TIRR regulates 53BP1 by masking its histone methyl-lysine binding function.

    PubMed

    Drané, Pascal; Brault, Marie-Eve; Cui, Gaofeng; Meghani, Khyati; Chaubey, Shweta; Detappe, Alexandre; Parnandi, Nishita; He, Yizhou; Zheng, Xiao-Feng; Botuyan, Maria Victoria; Kalousi, Alkmini; Yewdell, William T; Münch, Christian; Harper, J Wade; Chaudhuri, Jayanta; Soutoglou, Evi; Mer, Georges; Chowdhury, Dipanjan

    2017-03-09

    P53-binding protein 1 (53BP1) is a multi-functional double-strand break repair protein that is essential for class switch recombination in B lymphocytes and for sensitizing BRCA1-deficient tumours to poly-ADP-ribose polymerase-1 (PARP) inhibitors. Central to all 53BP1 activities is its recruitment to double-strand breaks via the interaction of the tandem Tudor domain with dimethylated lysine 20 of histone H4 (H4K20me2). Here we identify an uncharacterized protein, Tudor interacting repair regulator (TIRR), that directly binds the tandem Tudor domain and masks its H4K20me2 binding motif. Upon DNA damage, the protein kinase ataxia-telangiectasia mutated (ATM) phosphorylates 53BP1 and recruits RAP1-interacting factor 1 (RIF1) to dissociate the 53BP1-TIRR complex. However, overexpression of TIRR impedes 53BP1 function by blocking its localization to double-strand breaks. Depletion of TIRR destabilizes 53BP1 in the nuclear-soluble fraction and alters the double-strand break-induced protein complex centring 53BP1. These findings identify TIRR as a new factor that influences double-strand break repair using a unique mechanism of masking the histone methyl-lysine binding function of 53BP1.

  7. Double exposure technique for 45nm node and beyond

    NASA Astrophysics Data System (ADS)

    Hsu, Stephen; Park, Jungchul; Van Den Broeke, Douglas; Chen, J. Fung

    2005-11-01

    The technical challenges in using F2 lithography for the 45nm node, along with the insurmountable difficulties in EUV lithography, has driven the semiconductor chipmaker into the low k1 lithography era under the pressure of ever decreasing feature sizes. Extending lithography towards lower k1 puts heavy demand on the resolution enhancement technique (RET), exposure tool, and the need for litho friendly design. Hyper numerical aperture (NA) exposure tools, immersion, and double exposure techniques (DET's) are the promising methods to extend lithography manufacturing to the 45nm node at k1 factors below 0.3. Scattering bars (SB's) have become an integral part of the lithography process as chipmakers move to production at ever lower k1 factors. To achieve better critical dimension (CD) control, polarization is applied to enhance the image contrast in the preferential imaging orientation, which increases the risk of SB printability. The optimum SB width is approximately (0.20 ~ 0.25)*(λ/NA). When the SB width becomes less than the exposure wavelength on the 4X mask, Kirchhoff's scalar theory under predicts the SB intensity. The optical weighting factor of the SB increases (Figure 1b) and the SB's become more susceptible to printing. Meanwhile, under hyper NA conditions, the effectiveness of "subresolution" SB's is significantly diminished. A full-sized scattering bars (FSB) scheme becomes necessary. Double exposure methods, such as using ternary 6% attenuated PSM (attPSM) for DDL, are good imaging solutions that can reach and likely go beyond the 45nm node. Today DDL, using binary chrome masks, is capable of printing 65 nm device patterns. In this work, we investigate the use of DET with 6% attPSM masks to target 45nm node device. The SB scalability and printability issues can be taken cared of by using "mutual trimming", i.e., with the combined energy from the two exposures. In this study, we share our findings of using DET to pattern a 45nm node device design with polarization and immersion. We also explore other double patterning methods which in addition to having two exposures, incorporates double coat/developing/etch processing to break the 0.25 k1 barrier.

  8. Interactions of double patterning technology with wafer processing, OPC and design flows

    NASA Astrophysics Data System (ADS)

    Lucas, Kevin; Cork, Chris; Miloslavsky, Alex; Luk-Pat, Gerry; Barnes, Levi; Hapli, John; Lewellen, John; Rollins, Greg; Wiaux, Vincent; Verhaegen, Staf

    2008-03-01

    Double patterning technology (DPT) is one of the main options for printing logic devices with half-pitch less than 45nm; and flash and DRAM memory devices with half-pitch less than 40nm. DPT methods decompose the original design intent into two individual masking layers which are each patterned using single exposures and existing 193nm lithography tools. The results of the individual patterning layers combine to re-create the design intent pattern on the wafer. In this paper we study interactions of DPT with lithography, masks synthesis and physical design flows. Double exposure and etch patterning steps create complexity for both process and design flows. DPT decomposition is a critical software step which will be performed in physical design and also in mask synthesis. Decomposition includes cutting (splitting) of original design intent polygons into multiple polygons where required; and coloring of the resulting polygons. We evaluate the ability to meet key physical design goals such as: reduce circuit area; minimize rework; ensure DPT compliance; guarantee patterning robustness on individual layer targets; ensure symmetric wafer results; and create uniform wafer density for the individual patterning layers.

  9. Reducing Dental Plaque and Gingivitis With 0.6% Cortex Ilicis Rotundae Toothpaste: A Randomized, Double-Masked Clinical Trial.

    PubMed

    Liu, Hongchun; Yin, Wei

    2016-03-01

    Cortex Ilicis Rotundae has antioxidant and anti-inflammatory properties. Few studies have evaluated the effects of toothpastes containing Cortex Ilicis Rotundae. This study evaluates the antiplaque and antigingivitis effects of a test toothpaste containing 0.6% Cortex Ilicis Rotundae extract in a calcium carbonate base compared with a control toothpaste without any active ingredient. One hundred adults with a mean plaque index (PI) ≥ 1.5 and a mean gingival index (GI) ≥ 1.0 were enrolled in this randomized, double-masked, placebo-controlled clinical trial. They were assigned randomly to use a test toothpaste or a control toothpaste. At baseline, 6 weeks, and 12 weeks, they received examinations of oral hard and soft tissues, using Löe-Silness GI for gingivitis and the Turesky modification of the Quigley-Hein PI for PI. Adverse events were monitored. When the study was completed, the test group reported lower mean GI than the control group (1.13 ± 0.22 versus 1.30 ± 0.23; P = 0.001) and lower mean PI than the control group (2.53 ± 0.5 versus 2.93 ± 0.44; P < 0.001). Compared to the baseline, the test group had reductions in GI and PI of 14.39% and 17.86%, respectively (both P < 0.001); the control group had reductions in GI and PI of 3.7% and 3.93%, respectively (both P < 0.001). No adverse events were reported during the course of the study. The toothpaste containing 0.6% Cortex Ilicis Rotundae was effective in reducing dental plaque and gingivitis after 12 weeks of use compared with a negative control toothpaste.

  10. Blood Pressure Control in Hypertensive Patients, Cardiovascular Risk Profile and the Prevalence of Masked Uncontrolled Hypertension (MUCH).

    PubMed

    Naser, Nabil; Dzubur, Alen; Durak, Azra; Kulic, Mehmed; Naser, Nura

    2016-07-27

    The term masked hypertension (MH) should be used for untreated individuals who have normal office blood pressure but elevated ambulatory blood pressure. For treated patients, this condition should be termed masked uncontrolled hypertension (MUCH). Masked uncontrolled hypertension (MUCH) has gone unrecognized because few studies have used 24-h ABPM to determine the prevalence of suboptimal BP control in seemingly well-treated patients, and there are few such studies in large cohorts of treated patients attending usual clinical practice. This is important because masked hypertension is associated with a high risk of cardiovascular events. This study was conducted to obtain more information about the association between hypertension and other CV risk factors, about office and ambulatory blood pressure (BP) control as well as on cardiovascular (CV) risk profile in treated hypertensive patients, also to define the prevalence and characteristics of masked uncontrolled hypertension (MUCH) among treated hypertensive patients in routine clinical practice. In this study 2514 male and female patients were included during a period of 5 years follow up. All patients have ambulatory blood pressure monitoring (ABPM) for at least 24h. We identified patients with treated and controlled BP according to current international guidelines (clinic BP, 140/90mmHg). Cardiovascular risk assessment was based on personal history, clinic BP values, as well as target organ damage evaluation. Masked uncontrolled hypertension (MUCH) was diagnosed in these patients if despite controlled clinic BP, the mean 24-h ABPM average remained elevated (24-h systolic BP ≥130mmHg and/or 24-h diastolic BP ≥80mmHg). Patients had a mean age of 60.2+10 years, and the majority of them (94.6%) were followed by specialist physicians. Average clinic BP was 150.4+16/89.9+12 mmHg. About 70% of patients displayed a very high-risk profile. Ambulatory blood pressure monitoring (ABPM) was performed in all recruited patients for at least 24h. Despite the combined medical treatment (78% of the patients), clinic control (<140/90 mmHg) was achieved in only 26.2% of patients, the corresponding control rate for ambulatory BP (<130/80 mmHg) being 32.7%. From 2514 patients with treated BP, we identified 803 with treated and controlled office BP control (<140/90 mmHg), of whom 258 patients (32.1%) had MUCH according to 24-h ABPM criteria (mean age 57.2 years, 54.7% men). The prevalence of MUCH was slightly higher in males, patients with borderline clinic and office BP (130-139/80-89 mmHg), and patients at high cardiovascular risk (smokers, diabetes, obesity). Masked uncontrolled hypertension (MUCH) was most often due to poor control of nocturnal BP, with the proportion of patients in whom MUCH was solely attributable to an elevated nocturnal BP almost double that solely attributable to daytime BP elevation (22.3 vs. 10.1%, P 0.001). The prevalence of masked suboptimal BP control in patients with treated and well-controlled clinic BP is high. The characteristics of patients with MUCH (male, longer duration of hypertension, obesity, smoking history, and diabetes) indicate that this is a higher-risk group with most to gain from improved BP.

  11. Line-frequency doubling of directed self-assembly patterns for single-digit bit pattern media lithography

    NASA Astrophysics Data System (ADS)

    Patel, K. C.; Ruiz, R.; Lille, J.; Wan, L.; Dobiz, E.; Gao, H.; Robertson, N.; Albrecht, T. R.

    2012-03-01

    Directed self-assembly is emerging as a promising technology to define sub-20nm features. However, a straightforward path to scale block copolymer lithography to single-digit fabrication remains challenging given the diverse material properties found in the wide spectrum of self-assembling materials. A vast amount of block copolymer research for industrial applications has been dedicated to polystyrene-b-methyl methacrylate (PS-b-PMMA), a model system that displays multiple properties making it ideal for lithography, but that is limited by a weak interaction parameter that prevents it from scaling to single-digit lithography. Other block copolymer materials have shown scalability to much smaller dimensions, but at the expense of other material properties that could delay their insertion into industrial lithographic processes. We report on a line doubling process applied to block copolymer patterns to double the frequency of PS-b-PMMA line/space features, demonstrating the potential of this technique to reach single-digit lithography. We demonstrate a line-doubling process that starts with directed self-assembly of PS-b-PMMA to define line/space features. This pattern is transferred into an underlying sacrificial hard-mask layer followed by a growth of self-aligned spacers which subsequently serve as hard-masks for transferring the 2x frequency doubled pattern to the underlying substrate. We applied this process to two different block copolymer materials to demonstrate line-space patterns with a half pitch of 11nm and 7nm underscoring the potential to reach single-digit critical dimensions. A subsequent patterning step with perpendicular lines can be used to cut the fine line patterns into a 2-D array of islands suitable for bit patterned media. Several integration challenges such as line width control and line roughness are addressed.

  12. Multi-shaped beam: development status and update on lithography results

    NASA Astrophysics Data System (ADS)

    Slodowski, Matthias; Doering, Hans-Joachim; Dorl, Wolfgang; Stolberg, Ines A.

    2011-04-01

    According to the ITRS [1] photo mask is a significant challenge for the 22nm technology node requirements and beyond. Mask making capability and cost escalation continue to be critical for future lithography progress. On the technological side mask specifications and complexity have increased more quickly than the half-pitch requirements on the wafer designated by the roadmap due to advanced optical proximity correction and double patterning demands. From the economical perspective mask costs have significantly increased each generation, in which mask writing represents a major portion. The availability of a multi-electron-beam lithography system for mask write application is considered a potential solution to overcome these challenges [2, 3]. In this paper an update of the development status of a full-package high-throughput multi electron-beam writer, called Multi Shaped Beam (MSB), will be presented. Lithography performance results, which are most relevant for mask writing applications, will be disclosed. The MSB technology is an evolutionary development of the matured single Variable Shaped Beam (VSB) technology. An arrangement of Multi Deflection Arrays (MDA) allows operation with multiple shaped beams of variable size, which can be deflected and controlled individually [4]. This evolutionary MSB approach is associated with a lower level of risk and a relatively short time to implementation compared to the known revolutionary concepts [3, 5, 6]. Lithography performance is demonstrated through exposed pattern. Further details of the substrate positioning platform performance will be disclosed. It will become apparent that the MSB operational mode enables lithography on the same and higher performance level compared to single VSB and that there are no specific additional lithography challenges existing beside those which have already been addressed [1].

  13. Forward masking as a mechanism of automatic gain control in odontocete biosonar: a psychophysical study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2008-07-01

    In a false killer whale Pseudorca crassidens, echo perception thresholds were measured using a go/no-go psychophysical paradigm and one-up-one-down staircase procedure. Computer controlled echoes were electronically synthesized pulses that were played back through a transducer and triggered by whale emitted biosonar pulses. The echo amplitudes were proportional to biosonar pulse amplitudes; echo levels were specified in terms of the attenuation of the echo sound pressure level near the animal's head relative to the source level of the biosonar pulses. With increasing echo delay, the thresholds (echo attenuation factor) decreased from -49.3 dB at 2 ms to -79.5 dB at 16 ms, with a regression slope of -9.5 dB per delay doubling (-31.5 dB per delay decade). At the longer delays, the threshold remained nearly constant around -80.4 dB. Levels of emitted pulses slightly increased with delay prolongation (threshold decrease), with a regression slope of 3.2 dB per delay doubling (10.7 dB per delay decade). The echo threshold dependence on delay is interpreted as a release from forward masking by the preceding emitted pulse. This release may compensate for the echo level decrease with distance, thus keeping the echo sensation level for the animal near constant within a certain distance range.

  14. Power spectrum model of visual masking: simulations and empirical data.

    PubMed

    Serrano-Pedraza, Ignacio; Sierra-Vázquez, Vicente; Derrington, Andrew M

    2013-06-01

    In the study of the spatial characteristics of the visual channels, the power spectrum model of visual masking is one of the most widely used. When the task is to detect a signal masked by visual noise, this classical model assumes that the signal and the noise are previously processed by a bank of linear channels and that the power of the signal at threshold is proportional to the power of the noise passing through the visual channel that mediates detection. The model also assumes that this visual channel will have the highest ratio of signal power to noise power at its output. According to this, there are masking conditions where the highest signal-to-noise ratio (SNR) occurs in a channel centered in a spatial frequency different from the spatial frequency of the signal (off-frequency looking). Under these conditions the channel mediating detection could vary with the type of noise used in the masking experiment and this could affect the estimation of the shape and the bandwidth of the visual channels. It is generally believed that notched noise, white noise and double bandpass noise prevent off-frequency looking, and high-pass, low-pass and bandpass noises can promote it independently of the channel's shape. In this study, by means of a procedure that finds the channel that maximizes the SNR at its output, we performed numerical simulations using the power spectrum model to study the characteristics of masking caused by six types of one-dimensional noise (white, high-pass, low-pass, bandpass, notched, and double bandpass) for two types of channel's shape (symmetric and asymmetric). Our simulations confirm that (1) high-pass, low-pass, and bandpass noises do not prevent the off-frequency looking, (2) white noise satisfactorily prevents the off-frequency looking independently of the shape and bandwidth of the visual channel, and interestingly we proved for the first time that (3) notched and double bandpass noises prevent off-frequency looking only when the noise cutoffs around the spatial frequency of the signal match the shape of the visual channel (symmetric or asymmetric) involved in the detection. In order to test the explanatory power of the model with empirical data, we performed six visual masking experiments. We show that this model, with only two free parameters, fits the empirical masking data with high precision. Finally, we provide equations of the power spectrum model for six masking noises used in the simulations and in the experiments.

  15. Phase 2 Randomized, Double-Masked, Vehicle-Controlled Trial of Recombinant Human Nerve Growth Factor for Neurotrophic Keratitis.

    PubMed

    Bonini, Stefano; Lambiase, Alessandro; Rama, Paolo; Sinigaglia, Francesco; Allegretti, Marcello; Chao, Wendy; Mantelli, Flavio

    2018-04-10

    To evaluate the safety and efficacy of topical recombinant human nerve growth factor (rhNGF) for treating moderate-to-severe neurotrophic keratitis (NK), a rare degenerative corneal disease resulting from impaired corneal innervation. Phase 2 multicenter, randomized, double-masked, vehicle-controlled trial. Patients with stage 2 (moderate) or stage 3 (severe) NK in 1 eye. The REPARO phase 2 study assessed safety and efficacy in 156 patients randomized 1:1:1 to rhNGF 10 μg/ml, 20 μg/ml, or vehicle. Treatment was administered 6 drops per day for 8 weeks. Patients then entered a 48- or 56-week follow-up period. Safety was assessed in all patients who received study treatment, whereas efficacy was by intention to treat. Corneal healing (defined as <0.5-mm maximum diameter of fluorescein staining in the lesion area) was assessed by masked central readers at week 4 (primary efficacy end point) and week 8 (key secondary end point) of controlled treatment. Corneal healing was reassessed post hoc by masked central readers using a more conservative measure (0-mm staining in the lesion area and no other persistent staining). At week 4 (primary end point), 19.6% of vehicle-treated patients achieved corneal healing (<0.5-mm lesion staining) versus 54.9% receiving rhNGF 10 μg/ml (+35.3%; 97.06% confidence interval [CI], 15.88-54.71; P < 0.001) and 58.0% receiving rhNGF 20 μg/ml (+38.4%; 97.06% CI, 18.96-57.83; P < 0.001). At week 8 (key secondary end point), 43.1% of vehicle-treated patients achieved less than 0.5-mm lesion staining versus 74.5% receiving rhNGF 10 μg/ml (+31.4%; 97.06% CI, 11.25-51.49; P = 0.001) and 74.0% receiving rhNGF 20 μg/ml (+30.9%; 97.06% CI, 10.60-51.13; P = 0.002). Post hoc analysis of corneal healing by the more conservative measure (0-mm lesion staining and no other persistent staining) maintained statistically significant differences between rhNGF and vehicle at weeks 4 and 8. More than 96% of patients who healed after controlled rhNGF treatment remained recurrence free during follow-up. Treatment with rhNGF was well tolerated; adverse effects were mostly local, mild, and transient. Topical rhNGF is safe and more effective than vehicle in promoting healing of moderate-to-severe NK. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Large-area soft x-ray projection lithography using multilayer mirrors structured by RIE

    NASA Astrophysics Data System (ADS)

    Rahn, Steffen; Kloidt, Andreas; Kleineberg, Ulf; Schmiedeskamp, Bernt; Kadel, Klaus; Schomburg, Werner K.; Hormes, F. J.; Heinzmann, Ulrich

    1993-01-01

    SXPL (soft X-ray projection lithography) is one of the most promising applications of X-ray reflecting optics using multilayer mirrors. Within our collaboration, such multilayer mirrors were fabricated, characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors were produced by electron beam evaporation in UHV under thermal treatment with an in-situ X-ray controlled thickness in the region of 2d equals 14 nm. The reflectivities measured at normal incidence reached up to 54%. Various surface analysis techniques have been applied in order to characterize and optimize the X-ray mirrors. The multilayers were patterned by reactive ion etching (RIE) with CF(subscript 4), using a photoresist as the etch mask, thus producing X-ray reflection masks. The masks were tested in the synchrotron radiation laboratory of the electron accelerator ELSA at the Physikalisches Institut of Bonn University. A double crystal X-ray monochromator was modified so as to allow about 0.5 cm(superscript 2) of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto the resist (Hoechst AZ PF 514), which was mounted at an average distance of about 7 mm. In the first test-experiments, structure sizes down to 8 micrometers were nicely reproduced over the whole of the exposed area. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  17. Analgesic efficacy of lidocaine for suction-assisted lipectomy with tumescent technique under general anesthesia: a randomized, double-masked, controlled trial.

    PubMed

    Danilla, Stefan; Fontbona, Montserrat; de Valdés, Victoria Diaz; Dagnino, Bruno; Sorolla, Juan Pablo; Israel, Guillermo; Searle, Susana; Norambuena, Hernán; Cabello, Rodrigo

    2013-08-01

    Suction-assisted lipectomy is one of the most common procedures performed in plastic surgery. To minimize blood loss and to obtain adequate analgesia, a liquid solution is infiltrated into the subcutaneous plane before suction. The objective of this study was to determine whether the use of lidocaine in the infiltration solution reduces postoperative pain. A prospective, randomized, double-masked, clinical trial was designed. Each side of patients' body zones to be treated with suction-assisted lipectomy was randomized to receive infiltration solution with or without lidocaine. Treatment allocation was performed using computer-generated random numbers in permuted blocks of eight. Pain was assessed using the visual analogue scale and registered 1, 6, 12, 18, and 24 hours after the procedure. The trial was stopped after a first interim analysis. The use of lidocaine in the dilute solution reduced pain by 0.5 point on the visual analogue scale (95 percent CI, 0.3 to 0.8; p<0.001). The effect was independent of the suctioned body zone (p=0.756), and lasted until 18 hours after surgery. Its analgesic effect was lost at the 24-hour postoperative control. Pain increased an average of 0.018 point on the visual analogue scale per hour (95 percent CI, 0.001 to 0.036; p=0.043). The use of lidocaine in the infiltration solution is effective in postoperative pain control until 18 hours after surgery. Nevertheless, its clinical effect is limited and clinically irrelevant, and therefore it is no longer used by the authors. Therapeutic, I.

  18. Results of a Multicenter, Randomized, Double-Masked, Placebo-Controlled Clinical Study of the Efficacy and Safety of Visomitin Eye Drops in Patients with Dry Eye Syndrome.

    PubMed

    Brzheskiy, Vladimir V; Efimova, Elena L; Vorontsova, Tatiana N; Alekseev, Vladimir N; Gusarevich, Olga G; Shaidurova, Ksenia N; Ryabtseva, Alla A; Andryukhina, Olga M; Kamenskikh, Tatiana G; Sumarokova, Elena S; Miljudin, Eugeny S; Egorov, Eugeny A; Lebedev, Oleg I; Surov, Alexander V; Korol, Andrii R; Nasinnyk, Illia O; Bezditko, Pavel A; Muzhychuk, Olena P; Vygodin, Vladimir A; Yani, Elena V; Savchenko, Alla Y; Karger, Elena M; Fedorkin, Oleg N; Mironov, Alexander N; Ostapenko, Victoria; Popeko, Natalia A; Skulachev, Vladimir P; Skulachev, Maxim V

    2015-12-01

    This article presents the results of an international, multicenter, randomized, double-masked, placebo-controlled clinical study of Visomitin (Mitotech LLC, Moscow, Russian Federation) eye drops in patients with dry eye syndrome (DES). Visomitin is the first registered (in Russia) drug with a mitochondria-targeted antioxidant (SkQ1) as the active ingredient. In this multicenter (10 sites) study of 240 subjects with DES, study drug (Visomitin or placebo) was self-administered three times daily (TID) for 6 weeks, followed by a 6-week follow-up period. Seven in-office study visits occurred every 2 weeks during both the treatment and follow-up periods. Efficacy measures included Schirmer's test, tear break-up time, fluorescein staining, meniscus height, and visual acuity. Safety measures included adverse events, slit lamp biomicroscopy, tonometry, blood pressure, and heart rate. Tolerability was also evaluated. This clinical study showed the effectiveness of Visomitin eye drops in the treatment of signs and symptoms of DES compared with placebo. The study showed that a 6-week course of TID topical instillation of Visomitin significantly improved the functional state of the cornea; Visomitin increased tear film stability and reduced corneal damage. Significant reduction of dry eye symptoms (such as dryness, burning, grittiness, and blurred vision) was also observed. Based on the results of this study, Visomitin is effective and safe for use in eye patients with DES for protection from corneal damage. Mitotech LLC.

  19. X ray reflection masks: Manufacturing, characterization and first tests

    NASA Astrophysics Data System (ADS)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  20. Metacontrast masking is processed before grapheme-color synesthesia.

    PubMed

    Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S

    2013-01-01

    We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.

  1. Forward-masking based gain control in odontocete biosonar: an evoked-potential study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2009-04-01

    Auditory evoked potentials (AEPs) were recorded during echolocation in a false killer whale Pseudorca crassidens. An electronically synthesized and played-back ("phantom") echo was used. Each electronic echo was triggered by an emitted biosonar pulse. The echo had a spectrum similar to that of the emitted biosonar clicks, and its intensity was proportional to that of the emitted click. The attenuation of the echo relative to the emitted click and its delay was controlled by the experimenter. Four combinations of echo attenuation and delay were tested (-31 dB, 2 ms), (-40 dB, 4 ms), (-49 dB, 8 ms), and (-58 dB, 16 ms); thus, attenuation and delay were associated with a rate of 9 dB of increased attenuation per delay doubling. AEPs related to emitted clicks displayed a regular amplitude dependence on the click level. Echo-related AEPs did not feature amplitude dependence on echo attenuation or emitted click levels, except in a few combinations of the lowest values of these two variables. The results are explained by a hypothesis that partial forward masking of the echoes by the preceding emitted sonar pulses serves as a kind of automatic gain control in the auditory system of echolocating odontocetes.

  2. [Primary Intracranial Malignant Lymphoma Associated with Acquired Immunodeficiency Syndrome(AIDS):A Case Report].

    PubMed

    Inaka, Yasufumi; Otani, Naoki; Nishida, Sho; Fujii, Kazuya; Ueno, Hideaki; Tomura, Satoshi; Tomiyama, Arata; Osada, Hideo; Wada, Kojiro; Maeda, Takuya; Mori, Kentaro

    2017-11-01

    The spread of human immunodeficiency virus(HIV)infection may result in an increased likelihood of surgery in patients with HIV infection. We treated a patient with intracranial malignant lymphoma associated with acquired immunodeficiency syndrome(AIDS)caused by HIV infection. The recommendations of the countermeasure manual for AIDS were followed. Only surgical staff without finger injury or inflammation were permitted to be involved in the operation. All staff were dressed in a waterproof, full-body surgical gown, and wore double gloves, double foot covers, and an N95 mask. The surgery could be performed safely with such infection control measures. Histological examination revealed a diffuse large B-cell lymphoma. The patient was referred to the Division of Infectious Diseases and Respiratory Medicine for chemotherapy.

  3. Diffraction-based overlay metrology for double patterning technologies

    NASA Astrophysics Data System (ADS)

    Dasari, Prasad; Korlahalli, Rahul; Li, Jie; Smith, Nigel; Kritsun, Oleg; Volkman, Cathy

    2009-03-01

    The extension of optical lithography to 32nm and beyond is made possible by Double Patterning Techniques (DPT) at critical levels of the process flow. The ease of DPT implementation is hindered by increased significance of critical dimension uniformity and overlay errors. Diffraction-based overlay (DBO) has shown to be an effective metrology solution for accurate determination of the overlay errors associated with double patterning [1, 2] processes. In this paper we will report its use in litho-freeze-litho-etch (LFLE) and spacer double patterning technology (SDPT), which are pitch splitting solutions that reduce the significance of overlay errors. Since the control of overlay between various mask/level combinations is critical for fabrication, precise and accurate assessment of errors by advanced metrology techniques such as spectroscopic diffraction based overlay (DBO) and traditional image-based overlay (IBO) using advanced target designs will be reported. A comparison between DBO, IBO and CD-SEM measurements will be reported. . A discussion of TMU requirements for 32nm technology and TMU performance data of LFLE and SDPT targets by different overlay approaches will be presented.

  4. A phase III, multi-centre, double-masked randomised controlled trial of adjunctive intraocular and peri-ocular steroid (triamcinolone acetonide) versus standard treatment in eyes undergoing vitreoretinal surgery for open globe trauma (ASCOT): statistical analysis plan.

    PubMed

    Lo, Jessica W; Bunce, Catey; Charteris, David; Banerjee, Philip; Phillips, Rachel; Cornelius, Victoria R

    2016-08-02

    Open globe ocular trauma complicated by intraocular scarring (proliferative vitreoretinopathy) is a relatively rare, blinding, but potentially treatable condition for which, at present, surgery is often unsatisfactory and visual results frequently poor. To date, no pharmacological adjuncts to surgery have been proven to be effective. The aim of the Adjunctive Steroid Combination in Ocular Trauma (ASCOT) randomised controlled trial is to determine whether adjunctive steroid (triamcinolone acetonide), given at the time of surgery, can improve the outcome of vitreoretinal surgery in patients with open globe ocular trauma. This article presents the statistical analysis plan for the main publication as approved and signed off by the Trial Steering Committee prior to the first data extraction for the Data Monitoring Committee meeting report. ASCOT is a pragmatic, multi-centre, parallel-group, double-masked randomised controlled trial. The aim of the study is to recruit from 20-25 centres in the United Kingdom and randomise 300 eyes (from 300 patients) into two treatment arms. Both groups will receive standard surgical treatment and care; the intervention arm will additionally receive a pre-operative steroid combination (triamcinolone acetonide) into the vitreous cavity consisting of 4 mg/0.1 ml and 40 mg/1 ml sub-Tenon's. Participants will be followed for 6 months post-surgery. The primary outcome is the proportion of patients achieving a clinically meaning improvement in visual acuity in the study eye at 6 months after initial surgery, defined as a 10 letter score improvement in the ETDRS (the standard scale to test visual acuity). ISRCTN30012492 . Registered on 5 September 2014. EudraCT2014-002193-37 . Registered on 5 September 2014.

  5. Effects of a Lutein and Zeaxanthin Intervention on Cognitive Function: A Randomized, Double-Masked, Placebo-Controlled Trial of Younger Healthy Adults.

    PubMed

    Renzi-Hammond, Lisa M; Bovier, Emily R; Fletcher, Laura M; Miller, L Stephen; Mewborn, Catherine M; Lindbergh, Cutter A; Baxter, Jeffrey H; Hammond, Billy R

    2017-11-14

    Background: Past studies have suggested that higher lutein (L) and zeaxanthin (Z) levels in serum and in the central nervous system (as quantified by measuring macular pigment optical density, MPOD) are related to improved cognitive function in older adults. Very few studies have addressed the issue of xanthophylls and cognitive function in younger adults, and no controlled trials have been conducted to date to determine whether or not supplementation with L + Z can change cognitive function in this population. Objective: The purpose of this study was to determine whether or not supplementation with L + Z could improve cognitive function in young (age 18-30), healthy adults. Design: A randomized, double-masked, placebo-controlled trial design was used. Fifty-one young, healthy subjects were recruited as part of a larger study on xanthophylls and cognitive function. Subjects were randomized into active supplement ( n = 37) and placebo groups ( n = 14). MPOD was measured psychophysically using customized heterochromatic flicker photometry. Cognitive function was measured using the CNS Vital Signs testing platform. MPOD and cognitive function were measured every four months for a full year of supplementation. Results: Supplementation increased MPOD significantly over the course of the year, vs. placebo ( p < 0.001). Daily supplementation with L + Z and increases in MPOD resulted in significant improvements in spatial memory ( p < 0.04), reasoning ability ( p < 0.05) and complex attention ( p < 0.04), above and beyond improvements due to practice effects. Conclusions: Supplementation with L + Z improves CNS xanthophyll levels and cognitive function in young, healthy adults. Magnitudes of effects are similar to previous work reporting correlations between MPOD and cognition in other populations.

  6. A double-masked, placebo-controlled study of fluoxetine for hypochondriasis.

    PubMed

    Fallon, Brian A; Petkova, Eva; Skritskaya, Natalia; Sanchez-Lacay, Arturo; Schneier, Franklin; Vermes, Donna; Cheng, Jianfeng; Liebowitz, Michael R

    2008-12-01

    This study assessed the efficacy, durability, and tolerability of fluoxetine for hypochondriasis, a disorder for which controlled pharmacological trials are scarce. Fifty-seven patients with hypochondriasis were enrolled: 12 discontinued during the placebo run-in, and 45 were randomized to either fluoxetine or placebo for 12 weeks (acute treatment). Responder status was defined as a Clinical Global Impression rating for hypochondriasis of much or very much improved. Secondary outcome measures included severity of hypochondriasis, somatization, anxiety, and depression. Responders to acute treatment entered a 12-week maintenance phase to week 24. Sustained responders at week 24 entered a 12-week double-masked discontinuation phase. Primary analysis used the intent-to-treat sample. More patients responded with improvement in hypochondriasis when given fluoxetine compared with placebo, starting at week 8 (50.0% vs 19.0%, P = 0.03) and continuing to week 12 (62.5% vs 33.3%, P = 0.05). Mean dose at week 12 dose was 51.4 mg (SD, +/-23 mg). The acute treatment response was maintained to week 24 with more responders in the fluoxetine compared with the placebo group (54.2% vs 23.8%, P = 0.04). Significant improvement was not noted on the continuous secondary outcomes measures of hypochondriasis, with the exception of the Clinical Global Impression hypochondriasis severity scale at week 24. Likelihood of response was not associated with severity of psychiatric comorbidity. Durability of response after controlled drug discontinuation could not be reasonably assessed, given the small sample size of patients who entered the discontinuation phase (n = 10). Fluoxetine was well tolerated, with no significant differences in discontinuation due to side effects between treatment groups. Fluoxetine is a moderately effective and well-tolerated treatment for hypochondriasis.

  7. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness.

    PubMed

    MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi

    2016-12-30

    Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. 6 major hospitals in 2 districts of Beijing, China. Cluster randomised controlled trial. 245 index cases with ILI. Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. ACTRN12613000852752; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness

    PubMed Central

    MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi

    2016-01-01

    Rationale Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Objective Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. Setting 6 major hospitals in 2 districts of Beijing, China. Design Cluster randomised controlled trial. Participants 245 index cases with ILI. Intervention Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Main outcome measure Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. Results In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. Conclusions The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. Trial registration number ACTRN12613000852752; Results. PMID:28039289

  9. Non-invasive ventilation: evaluation of CO2 washout by intentional leaking in three recent oronasal masks. A pilot study.

    PubMed

    Medrinal, C; Prieur, G; Contal, O; Villiot-Danger, E; Doyle, C; Reychler, G; Quieffin, J

    2015-05-01

    Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects. Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10). The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041). There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.

  10. Fast mask writers: technology options and considerations

    NASA Astrophysics Data System (ADS)

    Litt, Lloyd C.; Groves, Timothy; Hughes, Greg

    2011-04-01

    The semiconductor industry is under constant pressure to reduce production costs even as the complexity of technology increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which have added to the complexity of making masks because of the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low-k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that funding on the order of 50M to 90M for non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development poses a high risk for an individual supplier. The structure of the mask fabrication marketplace separates the mask writer equipment customer (the mask supplier) from the final customer (wafer manufacturer) that will be most effected by the increase in mask cost that will result if a high speed mask writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed.

  11. Face mask use and control of respiratory virus transmission in households.

    PubMed

    MacIntyre, C Raina; Cauchemez, Simon; Dwyer, Dominic E; Seale, Holly; Cheung, Pamela; Browne, Gary; Fasher, Michael; Wood, James; Gao, Zhanhai; Booy, Robert; Ferguson, Neil

    2009-02-01

    Many countries are stockpiling face masks for use as a nonpharmaceutical intervention to control virus transmission during an influenza pandemic. We conducted a prospective cluster-randomized trial comparing surgical masks, non-fit-tested P2 masks, and no masks in prevention of influenza-like illness (ILI) in households. Mask use adherence was self-reported. During the 2006 and 2007 winter seasons, 286 exposed adults from 143 households who had been exposed to a child with clinical respiratory illness were recruited. We found that adherence to mask use significantly reduced the risk for ILI-associated infection, but <50% of participants wore masks most of the time. We concluded that household use of face masks is associated with low adherence and is ineffective for controlling seasonal respiratory disease. However, during a severe pandemic when use of face masks might be greater, pandemic transmission in households could be reduced.

  12. Respiratory source control using a surgical mask: An in vitro study.

    PubMed

    Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C

    2016-07-01

    Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.

  13. Timolol LA: a double-masked, active-controlled, randomized, crossover, comfort, ocular safety, and systemic bioavailability study in healthy volunteers.

    PubMed

    Mundorf, Thomas K; Ogawa, Takahiro; Inui, Noritsugu; Naka, Hiroaki; Novack, Gary D; Crockett, R Stephens

    2005-03-01

    A new formulation of timolol with sorbic acid, timolol-LA (TLA) (Istaloldagger), has been developed which increases its ocular bioavailability. In the present study, we desired to evaluate the ocular comfort and systemic bioavailability of TLA in healthy volunteers in comparison to standard timolol maleate ophthalmic solution (TIM). This study was a randomized, double-masked, active-controlled, crossover evaluation of 0.5% TLA and 0.5% TIM, bid, in 12 normal healthy volunteers. Visits were at Days 0, 1, 2, 4 and 8 in each period, and there was a minimum 7 day interperiod washout. At all three post-dosing evaluation times (Day 1: Peak, Day 8: Trough, and Day 8: Peak), the 95% confidence interval for the difference between TLA and TIM was not more than 0.37 ng/mL. After administration of TLA, there was a greater incidence of burning/stinging and tearing, but not foreign body sensation, relative to TIM. In general, most symptoms were mild in intensity, and no subject discontinued treatment due to ocular discomfort. Both treatments decreased IOP to a similar level. TLA was relatively comfortable, with a safety profile consistent with further clinical development, and, with bid dosing (exaggerated [2X] that anticipated for clinical use), had a systemic bioavailability similar to that of TIM 0.5%, bid. The incidence of burning and stinging was higher with TLA than with TIM, although reports were mild in severity and did not result in any patient discontin uations. Although the results are of interest, further evaluation in a larger trial may be warranted.

  14. Joint seismic data denoising and interpolation with double-sparsity dictionary learning

    NASA Astrophysics Data System (ADS)

    Zhu, Lingchen; Liu, Entao; McClellan, James H.

    2017-08-01

    Seismic data quality is vital to geophysical applications, so that methods of data recovery, including denoising and interpolation, are common initial steps in the seismic data processing flow. We present a method to perform simultaneous interpolation and denoising, which is based on double-sparsity dictionary learning. This extends previous work that was for denoising only. The original double-sparsity dictionary learning algorithm is modified to track the traces with missing data by defining a masking operator that is integrated into the sparse representation of the dictionary. A weighted low-rank approximation algorithm is adopted to handle the dictionary updating as a sparse recovery optimization problem constrained by the masking operator. Compared to traditional sparse transforms with fixed dictionaries that lack the ability to adapt to complex data structures, the double-sparsity dictionary learning method learns the signal adaptively from selected patches of the corrupted seismic data, while preserving compact forward and inverse transform operators. Numerical experiments on synthetic seismic data indicate that this new method preserves more subtle features in the data set without introducing pseudo-Gibbs artifacts when compared to other directional multi-scale transform methods such as curvelets.

  15. Optical image cryptosystem using chaotic phase-amplitude masks encoding and least-data-driven decryption by compressive sensing

    NASA Astrophysics Data System (ADS)

    Lang, Jun; Zhang, Jing

    2015-03-01

    In our proposed optical image cryptosystem, two pairs of phase-amplitude masks are generated from the chaotic web map for image encryption in the 4f double random phase-amplitude encoding (DRPAE) system. Instead of transmitting the real keys and the enormous masks codes, only a few observed measurements intermittently chosen from the masks are delivered. Based on compressive sensing paradigm, we suitably refine the series expansions of web map equations to better reconstruct the underlying system. The parameters of the chaotic equations can be successfully calculated from observed measurements and then can be used to regenerate the correct random phase-amplitude masks for decrypting the encoded information. Numerical simulations have been performed to verify the proposed optical image cryptosystem. This cryptosystem can provide a new key management and distribution method. It has the advantages of sufficiently low occupation of the transmitted key codes and security improvement of information transmission without sending the real keys.

  16. Delaying in vivo exposure to a tarantula with very brief exposure to phobic stimuli.

    PubMed

    Siegel, Paul; Gallagher, Kimberly Alyse

    2015-03-01

    Research has documented the very brief exposure (VBE) effect: the reduction of phobic fear by continuous presentation of masked phobic pictures. In prior studies, phobic participants approached a live tarantula immediately after the masked stimuli were presented. This study tested the hypothesis that VBE would reduce phobic avoidance of the tarantula 24 h later. 86 spider-phobic participants were identified with a fear questionnaire and Behavioral Avoidance Test (BAT) with a live tarantula indicative of a DSM-IV diagnosis of Specific Phobia. One week later, they were randomly assigned in double-blind fashion to presentation of a continuous series of 25 trials of masked images of either spiders or flowers (33-ms each), i.e., to VBE or control exposure. The participants gave subjective distress ratings just before and after these exposures. Then they engaged in the BAT again either immediately thereafter or 24 h later to measure changes in avoidance of the tarantula. Masked images of spiders reduced avoidance of the tarantula both immediately after exposure and 24 h later without causing subjective distress. The effect sizes at these two time points did not significantly differ from each other. We did not manipulate awareness of the spider images by presenting them unmasked to a third group. Conclusions about the effect of awareness of the stimuli cannot be drawn. VBE induces a process of fear reduction before phobic individuals engage in in vivo exposure, which is more distressing. Thus, VBE may help phobic-resistant individuals start treatment more gradually.

  17. Formation of multiple focal spots using a high NA lens with a complex spiral phase mask

    NASA Astrophysics Data System (ADS)

    Lalithambigai, K.; Anbarasan, P. M.; Rajesh, K. B.

    2014-07-01

    The formation of a transversally polarized beam by transmitting a tightly focused double-ring-shaped azimuthally polarized beam through a complex spiral phase mask and high numerical aperture lens is presented based on vector diffraction theory. The generation of transversally polarized focal spot segment splitting and multiple focal spots is illustrated numerically. Moreover, we found that a properly designed complex spiral phase mask can move the focal spots along the optical axis in the z direction. Therefore, one can achieve a focal segment of two, three or multiple completely transversely polarized focal spots, which finds applications in optical trapping and in material processing technologies.

  18. Respiratory source control using a surgical mask: An in vitro study

    PubMed Central

    Patel, Rajeev B.; Skaria, Shaji D.; Mansour, Mohamed M.; Smaldone, Gerald C.

    2016-01-01

    ABSTRACT Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an “N95 respirator”) with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection. PMID:26225807

  19. Randomized trial of the effect of drug presentation on asthma outcomes: the American Lung Association Asthma Clinical Research Centers.

    PubMed

    Wise, Robert A; Bartlett, Susan J; Brown, Ellen D; Castro, Mario; Cohen, Rubin; Holbrook, Janet T; Irvin, Charles G; Rand, Cynthia S; Sockrider, Marianna M; Sugar, Elizabeth A

    2009-09-01

    Information that enhances expectations about drug effectiveness improves the response to placebos for pain. Although asthma symptoms often improve with placebo, it is not known whether the response to placebo or active treatment can be augmented by increasing expectation of benefit. The study objective was to determine whether response to placebo or a leukotriene antagonist (montelukast) can be augmented by messages that increase expectation of benefit. A randomized 20-center controlled trial enrolled 601 asthmatic patients with poor symptom control who were assigned to one of 5 study groups. Participants were randomly assigned to one of 4 treatment groups in a factorial design (ie, placebo with enhanced messages, placebo with neutral messages, montelukast with enhanced messages, or montelukast with neutral messages) or to usual care. Assignment to study drug was double masked, assignment to message content was single masked, and usual care was not masked. The enhanced message aimed to increase expectation of benefit from the drug. The primary outcome was mean change in daily peak flow over 4 weeks. Secondary outcomes included lung function and asthma symptom control. Peak flow and other lung function measures were not improved in participants assigned to the enhanced message groups versus the neutral messages groups for either montelukast or placebo; no differences were noted between the neutral placebo and usual care groups. Placebo-treated participants had improved asthma control with the enhanced message but not montelukast-treated participants; the neutral placebo group did have improved asthma control compared with the usual care group after adjusting for baseline difference. Headaches were more common in participants provided messages that mentioned headache as a montelukast side effect. Optimistic drug presentation augments the placebo effect for patient-reported outcomes (asthma control) but not lung function. However, the effect of montelukast was not enhanced by optimistic messages regarding treatment effectiveness.

  20. Active membrane masks for improved overlay performance in proximity lithography

    NASA Astrophysics Data System (ADS)

    Huston, Dryver R.; Plumpton, James; Esser, Brian; Sullivan, Gerald A.

    2004-07-01

    Membrane masks are thin (2 micron x 35 mm x 35 mm) structures that carry the master exposure patterns in proximity (X-ray) lithography. With the continuous drive to the printing of ever-finer features in microelectronics, the reduction of mask-wafer overlay positioning errors by passive rigid body positioning and passive stress control in the mask becomes impractical due to nano and sub-micron scale elastic deformations in the membrane mask. This paper describes the design, mechanics and performance of a system for actively stretching a membrane mask in-plane to control overlay distortion. The method uses thermoelectric heating/cooling elements placed on the mask perimeter. The thermoelectric elements cause controlled thermoelastic deformations in the supporting wafer, which in turn corrects distortions in the membrane mask. Silicon carbide masks are the focus of this study, but the method is believed to be applicable to other mask materials, such as diamond. Experimental and numerical results will be presented, as well as a discussion of the design issues and related design decisions.

  1. Fabrication of Fiber-Optic Tilted Bragg Grating Filter in 40 nm Range with A Single Phase Mask

    NASA Technical Reports Server (NTRS)

    Grant, Joseph; Wang, Y.; Sharma, A.; Burdine, Robert V. (Technical Monitor)

    2002-01-01

    Fiber-optic Bragg grating filters are fabricated with a range of Bragg wavelength between 1296 and 1336 nm, using a single phase mask. 30 mW of continuous-wave light at 244 nm is used from a frequency-doubled argon-ion laser having an intracavity etalon. Gratings are fabricated by tilting the photosensitive fiber with respect to the phase mask up to an angle of 15 degrees. The variation of Bragg wavelength with the fiber-tilt is explained with a simple formula. High spatial coherence of 244 nm light makes it possible to displace the fiber as much as 6 mm in front of the phase mask and tilt the fiber by as much as 15 degrees. This results in nearly constant band-width and near 100% reflectively for all gratings throughout the 40 nm range.

  2. Expanding the printable design space for lithography processes utilizing a cut mask

    NASA Astrophysics Data System (ADS)

    Wandell, Jerome; Salama, Mohamed; Wilkinson, William; Curtice, Mark; Feng, Jui-Hsuan; Gao, Shao Wen; Asthana, Abhishek

    2016-03-01

    The utilization of a cut-mask in semiconductor patterning processes has been in practice for logic devices since the inception of 32nm-node devices, notably with unidirectional gate level printing. However, the microprocessor applications where cut-mask patterning methods are used are expanding as Self-Aligned Double Patterning (SADP) processes become mainstream for 22/14nm fin diffusion, and sub-14nm metal levels. One common weakness for these types of lithography processes is that the initial pattern requiring the follow-up cut-mask typically uses an extreme off-axis imaging source such as dipole to enhance the resolution and line-width roughness (LWR) for critical dense patterns. This source condition suffers from poor process margin in the semi-dense (forbidden pitch) realm and wrong-way directional design spaces. Common pattern failures in these limited design regions include bridging and extra-printing defects that are difficult to resolve with traditional mask improvement means. This forces the device maker to limit the allowable geometries that a designer may use on a device layer. This paper will demonstrate methods to expand the usable design space on dipole-like processes such as unidirectional gate and SADP processes by utilizing the follow-up cut mask to improve the process window. Traditional mask enhancement means for improving the process window in this design realm will be compared to this new cut-mask approach. The unique advantages and disadvantages of the cut-mask solution will be discussed in contrast to those customary methods.

  3. Safety and efficacy of cocoa flavanol intake in healthy adults: a randomized, controlled, double-masked trial.

    PubMed

    Ottaviani, Javier I; Balz, Marion; Kimball, Jennifer; Ensunsa, Jodi L; Fong, Reedmond; Momma, Tony Y; Kwik-Uribe, Catherine; Schroeter, Hagen; Keen, Carl L

    2015-12-01

    Evidence from dietary intervention studies shows that the intake of flavanols and procyanidins can be beneficial for cardiovascular health. Nevertheless, there is a clear need for advancing our understanding with regard to safe amounts of intake for these bioactives. The aim was to investigate in healthy adults the effects of cocoa flavanol (CF) intake amount and intake duration on blood pressure, platelet function, metabolic variables, and potential adverse events (AEs). This investigation consisted of 2 parts. Part 1 was an open-label, intake-amount escalation study, in which 34 healthy adults (aged 35-55 y) consumed escalating amounts of CFs, ranging from 1000 to 2000 mg/d over 6 wk. Primary outcomes were blood pressure and platelet function, select metabolic variables, and the occurrence and severity of AEs. Secondary outcomes included plasma concentrations of CF-derived metabolites and methylxanthines. On the basis of the outcomes of study part 1, and assessing the same outcome measures, part 2 of this investigation was a controlled, randomized, double-masked, 2-parallel-arm dietary intervention study in which healthy participants (aged 35-55 y) were asked to consume for 12 consecutive weeks up to 2000 mg CFs/d (n = 46) or a CF-free control (n = 28). Daily intake of up to 2000 mg CFs/d for 12 wk was not associated with significant changes in blood pressure or platelet function compared with CF-free controls in normotensive, healthy individuals who exhibited a very low risk of cardiovascular disease. There were no clinically relevant changes in the metabolic variables assessed in either of the groups. AEs reported were classified as mild in severity and did not significantly differ between study arms. The consumption of CFs in amounts up to 2000 mg/d for 12 wk was well tolerated in healthy men and women. This trial was registered at clinicaltrials.gov as NCT02447770 (part 1) and NCT02447783 (part 2). © 2015 American Society for Nutrition.

  4. Quantitative evaluation of manufacturability and performance for ILT produced mask shapes using a single-objective function

    NASA Astrophysics Data System (ADS)

    Choi, Heon; Wang, Wei-long; Kallingal, Chidam

    2015-03-01

    The continuous scaling of semiconductor devices is quickly outpacing the resolution improvements of lithographic exposure tools and processes. This one-sided progression has pushed optical lithography to its limits, resulting in the use of well-known techniques such as Sub-Resolution Assist Features (SRAF's), Source-Mask Optimization (SMO), and double-patterning, to name a few. These techniques, belonging to a larger category of Resolution Enhancement Techniques (RET), have extended the resolution capabilities of optical lithography at the cost of increasing mask complexity, and therefore cost. One such technique, called Inverse Lithography Technique (ILT), has attracted much attention for its ability to produce the best possible theoretical mask design. ILT treats the mask design process as an inverse problem, where the known transformation from mask to wafer is carried out backwards using a rigorous mathematical approach. One practical problem in the application of ILT is the resulting contour-like mask shapes that must be "Manhattanized" (composed of straight edges and 90-deg corners) in order to produce a manufacturable mask. This conversion process inherently degrades the mask quality as it is a departure from the "optimal mask" represented by the continuously curved shapes produced by ILT. However, simpler masks composed of longer straight edges reduce the mask cost as it lowers the shot count and saves mask writing time during mask fabrication, resulting in a conflict between manufacturability and performance for ILT produced masks1,2. In this study, various commonly used metrics will be combined into an objective function to produce a single number to quantitatively measure a particular ILT solution's ability to balance mask manufacturability and RET performance. Several metrics that relate to mask manufacturing costs (i.e. mask vertex count, ILT computation runtime) are appropriately weighted against metrics that represent RET capability (i.e. process-variation band, edge-placement-error) in order to reflect the desired practical balance. This well-defined scoring system allows direct comparison of several masks with varying degrees of complexities. Using this method, ILT masks produced with increasing mask constraints will be compared, and it will be demonstrated that using the smallest minimum width for mask shapes does not always produce the optimal solution.

  5. Evaluating practical vs. theoretical inspection system capability with a new programmed defect test mask designed for 3X and 4X technology nodes

    NASA Astrophysics Data System (ADS)

    Glasser, Joshua; Pratt, Tim

    2008-10-01

    Programmed defect test masks serve the useful purpose of evaluating inspection system sensitivity and capability. It is widely recognized that when evaluating inspection system capability, it is important to understand the actual sensitivity of the inspection system in production; yet unfortunately we have observed that many test masks are a more accurate judge of theoretical sensitivity rather than real-world usable capability. Use of ineffective test masks leave the purchaser of inspection equipment open to the risks of over-estimating the capability of their inspection solution and overspecifying defect sensitivity to their customers. This can result in catastrophic yield loss for device makers. In this paper we examine some of the lithography-related technology advances which place an increasing burden on mask inspection complexity, such as MEEF, defect printability estimation, aggressive OPC, double patterning, and OPC jogs. We evaluate the key inspection system component contributors to successful mask inspection, including what can "go wrong" with these components. We designed and fabricated a test mask which both (a) more faithfully represents actual production use cases; and (b) stresses the key components of the inspection system. This mask's patterns represent 32nm, 36nm, and 45nm logic and memory technology including metal and poly like background patterns with programmed defects. This test mask takes into consideration requirements of advanced lithography, such as MEEF, defect printability, assist features, nearly-repetitive patterns, and data preparation. This mask uses patterns representative of 32nm, 36nm, and 45nm logic, flash, and DRAM technology. It is specifically designed to have metal and poly like background patterns with programmed defects. The mask is complex tritone and was designed for annular immersion lithography.

  6. Mask aligner for ultrahigh vacuum with capacitive distance control

    NASA Astrophysics Data System (ADS)

    Bhaskar, Priyamvada; Mathioudakis, Simon; Olschewski, Tim; Muckel, Florian; Bindel, Jan Raphael; Pratzer, Marco; Liebmann, Marcus; Morgenstern, Markus

    2018-04-01

    We present a mask aligner driven by three piezomotors which guides and aligns a SiN shadow mask under capacitive control towards a sample surface. The three capacitors for read out are located at the backside of the thin mask such that the mask can be placed at a μm distance from the sample surface, while keeping it parallel to the surface, without touching the sample by the mask a priori. Samples and masks can be exchanged in-situ and the mask can additionally be displaced parallel to the surface. We demonstrate an edge sharpness of the deposited structures below 100 nm, which is likely limited by the diffusion of the deposited Au on Si(111).

  7. Bimanual tapping of a syncopated rhythm reveals hemispheric preferences for relative movement frequencies.

    PubMed

    Pflug, Anja; Gompf, Florian; Kell, Christian Alexander

    2017-08-01

    In bimanual multifrequency tapping, right-handers commonly use the right hand to tap the relatively higher rate and the left hand to tap the relatively lower rate. This could be due to hemispheric specializations for the processing of relative frequencies. An extension of the double-filtering-by-frequency theory to motor control proposes a left hemispheric specialization for the control of relatively high and a right hemispheric specialization for the control of relatively low tapping rates. We investigated timing variability and rhythmic accentuation in right handers tapping mono- and multifrequent bimanual rhythms to test the predictions of the double-filtering-by-frequency theory. Yet, hemispheric specializations for the processing of relative tapping rates could be masked by a left hemispheric dominance for the control of known sequences. Tapping was thus either performed in an overlearned quadruple meter (tap of the slow rhythm on the first auditory beat) or in a syncopated quadruple meter (tap of the slow rhythm on the fourth auditory beat). Independent of syncopation, the right hand outperformed the left hand in timing accuracy for fast tapping. A left hand timing benefit for slow tapping rates as predicted by the double-filtering-by-frequency theory was only found in the syncopated tapping group. This suggests a right hemisphere preference for the control of slow tapping rates when rhythms are not overlearned. Error rates indicate that overlearned rhythms represent hierarchically structured meters that are controlled by a single timer that could potentially reside in the left hemisphere. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Saccharomyces boulardii to Prevent Antibiotic-Associated Diarrhea: A Randomized, Double-Masked, Placebo-Controlled Trial.

    PubMed

    Ehrhardt, Stephan; Guo, Nan; Hinz, Rebecca; Schoppen, Stefanie; May, Jürgen; Reiser, Markus; Schroeder, Maximilian Philipp; Schmiedel, Stefan; Keuchel, Martin; Reisinger, Emil C; Langeheinecke, Andreas; de Weerth, Andreas; Schuchmann, Marcus; Schaberg, Tom; Ligges, Sandra; Eveslage, Maria; Hagen, Ralf M; Burchard, Gerd D; Lohse, Ansgar W

    2016-01-01

    Background.  Antibiotic-associated diarrhea (AAD) and Clostridium difficile-associated diarrhea (CDAD) are common complications of antibiotic use. Data on the efficacy of probiotics to prevent AAD and CDAD are unclear. We aimed to evaluate the efficacy of Saccharomyces boulardii to prevent AAD and CDAD in hospitalized adult patients. Methods.  We conducted a multicenter, phase III, double-masked, randomized, placebo-controlled trial in hospitalized patients who received systemic antibiotic treatment in 15 hospitals in Germany between July 2010 and October 2012. Participants received Perenterol forte 250 mg capsules or matching placebo twice per day within 24 hours of initiating antibiotic treatment, continued treatment for 7 days after antibiotic discontinuation, and were then observed for 6 weeks. Results.  Two thousand four hundred forty-four patients were screened. The trial was stopped early for futility after inclusion of 477 participants. Two hundred forty-six patients aged 60.1 ± 16.5 years and 231 patients aged 56.5 ± 17.8 were randomized to the S boulardii group and the placebo group, respectively, with 21 and 19 AADs in the respective groups (P = .87). The hazard ratio of AAD in the S boulardii group compared with the placebo group was 1.02 (95% confidence interval, .55-1.90; P = .94). Clostridium difficile-associated diarrhea occurred in 0.8% of participants (4 of 477). Nine serious adverse events were recorded in the S boulardii group, and 3 serious adverse events were recorded in the placebo group. None were related to study participation. Conclusions.  We found no evidence for an effect of S boulardii in preventing AAD or CDAD in a population of hospitalized patients without particular risk factors apart from systemic antibiotic treatment. ClinicalTrials.gov Identifier.  NCT01143272.

  9. Are there specific benefits of amoxicillin plus metronidazole in Aggregatibacter actinomycetemcomitans-associated periodontitis? Double-masked, randomized clinical trial of efficacy and safety.

    PubMed

    Mombelli, Andrea; Cionca, Norbert; Almaghlouth, Adnan; Décaillet, Fabien; Courvoisier, Delphine S; Giannopoulou, Catherine

    2013-06-01

    It has been suggested that prescription of amoxicillin plus metronidazole in the context of periodontal therapy should be limited to patients with specific microbiologic profiles, especially those testing positive for Aggregatibacter actinomycetemcomitans. The main purpose of this analysis is to determine if patients positive for A. actinomycetemcomitans with moderate to advanced periodontitis benefit specifically from amoxicillin plus metronidazole given as an adjunct to full-mouth scaling and root planing. This is a double-masked, placebo-controlled, randomized longitudinal study including 41 participants who were positive for A. actinomycetemcomitans and 41 participants who were negative for A. actinomycetemcomitans. All 82 patients received full-mouth periodontal debridement performed within 48 hours. Patients then received either systemic antibiotics (375 mg amoxicillin and 500 mg metronidazole, three times daily) or placebo for 7 days. The primary outcome variable was persistence of sites with a probing depth (PD) >4 mm and bleeding on probing (BOP) at the 3-month reevaluation. Using multilevel logistic regression, the effect of the antibiotics was analyzed according to the following factors (interaction effect): A. actinomycetemcomitans-positive or -negative at baseline, sex, age, smoking, tooth being a molar, and interdental location. At reevaluation, participants in the test group had significantly fewer sites with a persisting PD >4 mm and BOP than control patients (P <0.01). Being A. actinomycetemcomitans-positive or -negative did not change the effect of the antibiotics. Patients benefited from the antibiotics irrespective of sex, age, or smoking status. Molars benefited significantly more from the antibiotics than non-molars (P for interaction effect = 0.03). Patients who were positive for A. actinomycetemcomitans had no specific benefit from amoxicillin plus metronidazole. Sites on molars benefited significantly more from the antibiotics than non-molar sites.

  10. Multiple beam mask writers: an industry solution to the write time crisis

    NASA Astrophysics Data System (ADS)

    Litt, Lloyd C.

    2010-09-01

    The semiconductor industry is under constant pressure to reduce production costs even as technology complexity increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which has added to the complexity of making masks through the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept mask write times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that $50M+ in non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development is a high risk for an individual supplier. The problem is compounded by a disconnect between the tool customer (the mask supplier) and the final mask customer that will bear the increased costs if a high speed writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed. Because SEMATECH's member companies strongly support a multiple beam technology for mask writers to reduce the write time and cost of 193 nm and EUV masks, SEMATECH plans to pursue an advanced mask writer program in 2011 and 2012. In 2010, efforts will focus on identifying a funding model to address the investment to develop such a technology.

  11. Clinical outcomes of combined versus separate carbachol and brimonidine drops in correcting presbyopia.

    PubMed

    Abdelkader, Almamoun; Kaufman, Herbert E

    2016-01-01

    To test and compare in a masked fashion the efficacy of using a parasympathomimetic drug (3% carbachol) and an alpha-2 agonist (0.2% brimonidine) in both combined and separate forms to create optically beneficial miosis to pharmacologically improve vision in presbyopia. A prospective, double-masked, randomized, controlled clinical trial was conducted. Ten naturally emmetropic and presbyopic subjects between 42 and 58 years old with uncorrected distance visual acuity of at least 20/20 in both eyes without additional ocular pathology were eligible for inclusion. All subjects received 3% carbachol and 0.2% brimonidine in both combined and separate forms, 3% carbachol alone and 0.2% brimonidine (control) alone in their non-dominant eye in a crossover manner with one week washout between tests. The subjects' pupil sizes and both near and distance visual acuities will be evaluated pre- and post-treatment at 1, 2, 4, and 8 h, by a masked examiner at the same room illumination. Statistically significant improvement in mean near visual acuity (NVA) was achieved in all subjects who received combined 3% carbachol and 0.2% brimonidine in the same formula compared with those who received separate forms or carbachol alone or brimonidine alone ( P  < 0.0001). Based on the data, the combined solution demonstrated greater efficacy than the other solutions that were tested. Improving the depth of focus by making the pupil small caused statistically significant improvement in near visual acuity, with no change in binocular distance vision. ACTRN12616001565437. Registered 11 November 2016.

  12. Numerical Generation of Double Star Images for Different Types of Telescopes

    NASA Astrophysics Data System (ADS)

    Xavier, Ademir

    2015-11-01

    This paper reviews the modeling of stellar images using diffraction theory applied to different types of telescope masks. The masks are projected by secondary mirror holder vanes (such as the spider type) or holes on the primary mirror which result in different configurations of single stellar images. Using Fast Fourier Transform, the image of binary stars with different magnitudes is calculated. Given the numerical results obtained, a discussion is presented on the best secondary vane configurations and on the effect of obstruction types for the separation of binary pairs with different magnitudes.

  13. Preserved subliminal processing and impaired conscious access in schizophrenia

    PubMed Central

    Del Cul, Antoine; Dehaene, Stanislas; Leboyer, Marion

    2006-01-01

    Background Studies of visual backward masking have frequently revealed an elevated masking threshold in schizophrenia. This finding has frequently been interpreted as indicating a low-level visual deficit. However, more recent models suggest that masking may also involve late and higher-level integrative processes, while leaving intact early “bottom-up” visual processing. Objectives We tested the hypothesis that the backward masking deficit in schizophrenia corresponds to a deficit in the late stages of conscious perception, whereas the subliminal processing of masked stimuli is fully preserved. Method 28 patients with schizophrenia and 28 normal controls performed two backward-masking experiments. We used Arabic digits as stimuli and varied quasi-continuously the interval with a subsequent mask, thus allowing us to progressively “unmask” the stimuli. We finely quantified their degree of visibility using both objective and subjective measures to evaluate the threshold duration for access to consciousness. We also studied the priming effect caused by the variably masked numbers on a comparison task performed on a subsequently presented and highly visible target number. Results The threshold delay between digit and mask necessary for the conscious perception of the masked stimulus was longer in patients compared to control subjects. This higher consciousness threshold in patients was confirmed by an objective and a subjective measure, and both measures were highly correlated for patients as well as for controls. However, subliminal priming of masked numbers was effective and identical in patients compared to controls. Conclusions Access to conscious report of masked stimuli is impaired in schizophrenia, while fast bottom-up processing of the same stimuli, as assessed by subliminal priming, is preserved. These findings suggest a high-level origin of the masking deficit in schizophrenia, although they leave open for further research its exact relation to previously identified bottom-up visual processing abnormalities. PMID:17146006

  14. M&A For Lithography Of Sparse Arrays Of Sub-Micrometer Features

    DOEpatents

    Brueck, Steven R.J.; Chen, Xiaolan; Zaidi, Saleem; Devine, Daniel J.

    1998-06-02

    Methods and apparatuses are disclosed for the exposure of sparse hole and/or mesa arrays with line:space ratios of 1:3 or greater and sub-micrometer hole and/or mesa diameters in a layer of photosensitive material atop a layered material. Methods disclosed include: double exposure interferometric lithography pairs in which only those areas near the overlapping maxima of each single-period exposure pair receive a clearing exposure dose; double interferometric lithography exposure pairs with additional processing steps to transfer the array from a first single-period interferometric lithography exposure pair into an intermediate mask layer and a second single-period interferometric lithography exposure to further select a subset of the first array of holes; a double exposure of a single period interferometric lithography exposure pair to define a dense array of sub-micrometer holes and an optical lithography exposure in which only those holes near maxima of both exposures receive a clearing exposure dose; combination of a single-period interferometric exposure pair, processing to transfer resulting dense array of sub-micrometer holes into an intermediate etch mask, and an optical lithography exposure to select a subset of initial array to form a sparse array; combination of an optical exposure, transfer of exposure pattern into an intermediate mask layer, and a single-period interferometric lithography exposure pair; three-beam interferometric exposure pairs to form sparse arrays of sub-micrometer holes; five- and four-beam interferometric exposures to form a sparse array of sub-micrometer holes in a single exposure. Apparatuses disclosed include arrangements for the three-beam, five-beam and four-beam interferometric exposures.

  15. Functional neuroanatomy of visual masking deficits in schizophrenia.

    PubMed

    Green, Michael F; Lee, Junghee; Cohen, Mark S; Engel, Steven A; Korb, Alexander S; Nuechterlein, Keith H; Wynn, Jonathan K; Glahn, David C

    2009-12-01

    Visual masking procedures assess the earliest stages of visual processing. Patients with schizophrenia reliably show deficits on visual masking, and these procedures have been used to explore vulnerability to schizophrenia, probe underlying neural circuits, and help explain functional outcome. To identify and compare regional brain activity associated with one form of visual masking (ie, backward masking) in schizophrenic patients and healthy controls. Subjects received functional magnetic resonance imaging scans. While in the scanner, subjects performed a backward masking task and were given 3 functional localizer activation scans to identify early visual processing regions of interest (ROIs). University of California, Los Angeles, and the Department of Veterans Affairs Greater Los Angeles Healthcare System. Nineteen patients with schizophrenia and 19 healthy control subjects. Main Outcome Measure The magnitude of the functional magnetic resonance imaging signal during backward masking. Two ROIs (lateral occipital complex [LO] and the human motion selective cortex [hMT+]) showed sensitivity to the effects of masking, meaning that signal in these areas increased as the target became more visible. Patients had lower activation than controls in LO across all levels of visibility but did not differ in other visual processing ROIs. Using whole-brain analyses, we also identified areas outside the ROIs that were sensitive to masking effects (including bilateral inferior parietal lobe and thalamus), but groups did not differ in signal magnitude in these areas. The study results support a key role in LO for visual masking, consistent with previous studies in healthy controls. The current results indicate that patients fail to activate LO to the same extent as controls during visual processing regardless of stimulus visibility, suggesting a neural basis for the visual masking deficit, and possibly other visual integration deficits, in schizophrenia.

  16. The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population.

    PubMed

    Goenadi, Catherina Josephine; Law, David Zhiwei; Lee, Jia Wen; Ong, Ee Lin; Chee, Wai Kitt; Cheng, Jason

    2016-01-01

    Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects. Tonometry was performed in both eyes of all subjects with an AVIA(®)Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan(®)Alcon). Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21-52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = -0.174, p = 0.283) or CCT (r = -0.123, p = 0.445). There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery.

  17. The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population

    PubMed Central

    Goenadi, Catherina Josephine; Law, David Zhiwei; Lee, Jia Wen; Ong, Ee Lin; Chee, Wai Kitt; Cheng, Jason

    2016-01-01

    Purpose Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects. Methods Tonometry was performed in both eyes of all subjects with an AVIA®Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan®Alcon). Results Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21–52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = −0.174, p = 0.283) or CCT (r = −0.123, p = 0.445). Conclusion There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery. PMID:27462262

  18. Optimizing defect inspection strategy through the use of design-aware database control layers

    NASA Astrophysics Data System (ADS)

    Stoler, Dvori; Ruch, Wayne; Ma, Weimin; Chakravarty, Swapnajit; Liu, Steven; Morgan, Ray; Valadez, John; Moore, Bill; Burns, John

    2007-10-01

    Resolution limitations in the mask making process can cause differences between the features that appear in a database and those printed to a reticle. These differences may result from intentional or unintentional features in the database exceeding the resolution limit of the mask making process such as small gaps or lines in the data, line end shortening on small sub-resolution assist features etc creating challenges to both mask writing and mask inspection. Areas with high variance from design to mask, often referred to as high MEEF areas (mask error enhancement factor), become highly problematic and can directly impact mask and device yield, mask manufacturing cycle time and ultimately mask costs. Specific to mask inspection it may be desirable to inspect certain non-critical or non-relevant features at reduced sensitivity so as not to detect real, but less significant process defects. In contrast there may also be times where increased sensitivity is required for critical mask features or areas. Until recently, this process was extremely manual, creating added time and cost to the mask inspection cycle. Shifting to more intelligent and automated inspection flows is the key focus of this paper. A novel approach to importing design data directly into the mask inspection to include both MDP generated MRC errors files and LRC generated MEEF files. The results of recently developed inspection and review capability based upon controlling defect inspection using design aware data base control layers on a pixel basis are discussed. Typical mask shop applications and implementations will be shown.

  19. Development, characterization and qualification of first GEM foils produced in India

    NASA Astrophysics Data System (ADS)

    Shah, Aashaq; Ahmed, Asar; Gola, Mohit; Sharma, Ram Krishna; Malhotra, Shivali; Kumar, Ashok; Naimuddin, Md.; Menon, Pradeep; Srinivasan, K.

    2018-06-01

    The increasing demand for Gas Electron Multiplier (GEM) foils has been driven by their application in many current and proposed high-energy physics experiments. Micropack, a Bengaluru-based company, has established and commercialized GEM foils for the first time in India. Micropack used the double-mask etching technique to successfully produce 10 cm × 10 cm GEM foil. In this paper, we report on the development as well as the geometrical and electrical properties of these foils, including the size uniformity of the holes and leakage current measurements. Our characterization studies show that the foils are of good quality and satisfy all the necessary quality control criteria.

  20. Double image encryption in Fresnel domain using wavelet transform, gyrator transform and spiral phase masks

    NASA Astrophysics Data System (ADS)

    Kumar, Ravi; Bhaduri, Basanta

    2017-06-01

    In this paper, we propose a new technique for double image encryption in the Fresnel domain using wavelet transform (WT), gyrator transform (GT) and spiral phase masks (SPMs). The two input mages are first phase encoded and each of them are then multiplied with SPMs and Fresnel propagated with distances d1 and d2, respectively. The single-level discrete WT is applied to Fresnel propagated complex images to decompose each into sub-band matrices i.e. LL, HL, LH and HH. Further, the sub-band matrices of two complex images are interchanged after modulation with random phase masks (RPMs) and subjected to inverse discrete WT. The resulting images are then both added and subtracted to get intermediate images which are further Fresnel propagated with distances d3 and d4, respectively. These outputs are finally gyrator transformed with the same angle α to get the encrypted images. The proposed technique provides enhanced security in terms of a large set of security keys. The sensitivity of security keys such as SPM parameters, GT angle α, Fresnel propagation distances are investigated. The robustness of the proposed techniques against noise and occlusion attacks are also analysed. The numerical simulation results are shown in support of the validity and effectiveness of the proposed technique.

  1. Effect of preoperative oral midazolam sedation on separation anxiety and emergence delirium among children undergoing dental treatment under general anesthesia.

    PubMed

    El Batawi, Hisham Yehia

    2015-01-01

    To investigate the possible effects of preoperative oral Midazolam on parental separation anxiety, emergence delirium, and post-anesthesia care unit time on children undergoing dental rehabilitation under general anesthesia. Randomized, prospective, double-blind study. Seventy-eight American Society of Anesthesiology (ASA) I children were divided into two groups of 39 each. Children of the first group were premedicated with oral Midazolam 0.5 mg/kg, while children of the control group were premedicated with a placebo. Scores for parental separation, mask acceptance, postoperative emergence delirium, and time spent in the post-anesthesia care unit were compared statistically. The test group showed significantly lower parental separation scores and high acceptance rate for anesthetic mask. There was no significant difference between the two groups regarding emergence delirium and time spent in post-anesthesia care unit. Preoperative oral Midazolam could be a useful adjunct in anxiety management for children suffering dental anxiety. The drug may not reduce the incidence of postoperative emergence delirium. The suggested dose does not seem to affect the post-anesthesia care unit time.

  2. On the benefit of high resolution and low aberrations for in-die mask registration metrology

    NASA Astrophysics Data System (ADS)

    Beyer, Dirk; Seidel, Dirk; Heisig, Sven; Steinert, Steffen; Töpfer, Susanne; Scherübl, Thomas; Hetzler, Jochen

    2014-10-01

    With the introduction of complex lithography schemes like double and multi - patterning and new design principles like gridded designs with cut masks the requirements for mask to mask overlay have increased dramatically. Still, there are some good news too for the mask industry since more mask are needed and qualified. Although always confronted with throughput demands, latest writing tool developments are able to keep pace with ever increasing pattern placement specs not only for global signatures but for in-die features within the active area. Placement specs less than 3nm (max. 3 Sigma) are expected and needed in all cases in order to keep the mask contribution to the overall overlay budget at an accepted level. The qualification of these masks relies on high precision metrology tools which have to fulfill stringent metrology as well as resolution constrains at the same time. Furthermore, multi-patterning and gridded designs with pinhole type cut masks are drivers for a paradigm shift in registration metrology from classical registration crosses to in-die registration metrology on production features. These requirements result in several challenges for registration metrology tools. The resolution of the system must be sufficiently high to resolve small production features. At the same time tighter repeatability is required. Furthermore, tool induced shift (TIS) limit the accuracy of in-die measurements. This paper discusses and demonstrates the importance of low illumination wavelength together with low aberrations for best contrast imaging for in-die registration metrology. Typical effects like tool induced shift are analyzed and evaluated using the ZEISS PROVE® registration metrology tool. Additionally, we will address performance gains when going to higher resolution. The direct impact on repeatability for small features by registration measurements will be discussed as well.

  3. Social learning spreads knowledge about dangerous humans among American crows.

    PubMed

    Cornell, Heather N; Marzluff, John M; Pecoraro, Shannon

    2012-02-07

    Individuals face evolutionary trade-offs between the acquisition of costly but accurate information gained firsthand and the use of inexpensive but possibly less reliable social information. American crows (Corvus brachyrhynchos) use both sources of information to learn the facial features of a dangerous person. We exposed wild crows to a novel 'dangerous face' by wearing a unique mask as we trapped, banded and released 7-15 birds at five study sites near Seattle, WA, USA. An immediate scolding response to the dangerous mask after trapping by previously captured crows demonstrates individual learning, while an immediate response by crows that were not captured probably represents conditioning to the trapping scene by the mob of birds that assembled during the capture. Later recognition of dangerous masks by lone crows that were never captured is consistent with horizontal social learning. Independent scolding by young crows, whose parents had conditioned them to scold the dangerous mask, demonstrates vertical social learning. Crows that directly experienced trapping later discriminated among dangerous and neutral masks more precisely than did crows that learned through social means. Learning enabled scolding to double in frequency and spread at least 1.2 km from the place of origin over a 5 year period at one site.

  4. PEEP-masks in patients with severe obstructive pulmonary disease: a negative report.

    PubMed

    Christensen, H R; Simonsen, K; Lange, P; Clementsen, P; Kampmann, J P; Viskum, K; Heideby, J; Koch, U

    1990-03-01

    Positive pressure during expiration by face masks applied by the patient has gained wide acceptance in the treatment of chronic bronchitis, but the efficacy is still unproven. The effect of 6 months of treatment with PEEP-masks (positive end-expiratory pressure) was therefore studied in 47 patients with severe irreversible obstructive pulmonary disease (forced expiratory volume in one second (FEV1) about 1 l), and mucus hypersecretion. Patients were double-blindly randomized to at least 45 min daily treatment with PEEP-masks with either 10 or 0 cm water pressure. After 6 months of treatment, no statistical difference was found between the two groups in change of median values (month 6 - month 0) of FEV1, forced vital capacity (FVC), arterial oxygen tension (PaO2), amount of sputum or dyspnoea. Median values of arterial carbon dioxide tension (PaCO2) decreased significantly (0.03 kPa) in the placebo group. Cough intensity and dyspnoea during walking on staircases improved significantly in the placebo group. No difference among groups was found in number of days bedridden, hospitalized, number of exacerbations or antibiotic consumption. We conclude, that the use of PEEP-masks in these patients is without clinical documentation and cannot be recommended.

  5. Intravitreal Sirolimus for Noninfectious Uveitis: A Phase III Sirolimus Study Assessing Double-masKed Uveitis TReAtment (SAKURA).

    PubMed

    Nguyen, Quan Dong; Merrill, Pauline T; Clark, W Lloyd; Banker, Alay S; Fardeau, Christine; Franco, Pablo; LeHoang, Phuc; Ohno, Shigeaki; Rathinam, Sivakumar R; Thurau, Stephan; Abraham, Abu; Wilson, Laura; Yang, Yang; Shams, Naveed

    2016-11-01

    To evaluate the efficacy and safety of intravitreal sirolimus in the treatment of noninfectious uveitis (NIU) of the posterior segment (i.e., posterior, intermediate, or panuveitis). Phase III, randomized, double-masked, active-controlled, 6-month study with intravitreal sirolimus. Adults with active NIU of the posterior segment (intermediate, posterior, or panuveitis), defined as a vitreous haze (VH) score >1+. Subjects discontinued NIU medications before baseline, except for systemic corticosteroids, which were allowed only for those already receiving them at baseline and were rapidly tapered after baseline per protocol. Intravitreal sirolimus assigned 1:1:1 at doses of 44 (active control), 440, or 880 μg, administered on Days 1, 60, and 120. The primary efficacy outcome was the percentage of subjects with VH 0 response at Month 5 (study eye) without use of rescue therapy. Secondary outcomes at Month 5 were VH 0 or 0.5+ response rate, corticosteroid tapering success rate (i.e., tapering to a prednisone-equivalent dosage of ≤5 mg/day), and changes in best-corrected visual acuity (BCVA). Adverse events during the double-masked treatment period are presented. A total of 347 subjects were randomized. Higher proportions of subjects in the intravitreal sirolimus 440 μg (22.8%; P = 0.025) and 880 μg (16.4%; P = 0.182) groups met the primary end point than in the 44 μg group (10.3%). Likewise, higher proportions of subjects in the 440 μg (52.6%; P = 0.008) and 880 μg (43.1%; P = 0.228) groups achieved a VH score of 0 or 0.5+ than in the 44 μg group (35.0%). Mean BCVA was maintained throughout the study in each dose group, and the majority of subjects receiving corticosteroids at baseline successfully tapered off corticosteroids (44 μg [63.6%], 440 μg [76.9%], and 880 μg [66.7%]). Adverse events in the treatment and active control groups were similar in incidence, and all doses were well tolerated. Intravitreal sirolimus 440 μg demonstrated a significant improvement in ocular inflammation with preservation of BCVA in subjects with active NIU of the posterior segment. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Placement-aware decomposition of a digital standard cells library for double patterning lithography

    NASA Astrophysics Data System (ADS)

    Wassal, Amr G.; Sharaf, Heba; Hammouda, Sherif

    2012-11-01

    To continue scaling the circuit features down, Double Patterning (DP) technology is needed in 22nm technologies and lower. DP requires decomposing the layout features into two masks for pitch relaxation, such that the spacing between any two features on each mask is greater than the minimum allowed mask spacing. The relaxed pitches of each mask are then processed on two separate exposure steps. In many cases, post-layout decomposition fails to decompose the layout into two masks due to the presence of conflicts. Post-layout decomposition of a standard cells block can result in native conflicts inside the cells (internal conflict), or native conflicts on the boundary between two cells (boundary conflict). Resolving native conflicts requires a redesign and/or multiple iterations for the placement and routing phases to get a clean decomposition. Therefore, DP compliance must be considered in earlier phases, before getting the final placed cell block. The main focus of this paper is generating a library of decomposed standard cells to be used in a DP-aware placer. This library should contain all possible decompositions for each standard cell, i.e., these decompositions consider all possible combinations of boundary conditions. However, the large number of combinations of boundary conditions for each standard cell will significantly increase the processing time and effort required to obtain all possible decompositions. Therefore, an efficient methodology is required to reduce this large number of combinations. In this paper, three different reduction methodologies are proposed to reduce the number of different combinations processed to get the decomposed library. Experimental results show a significant reduction in the number of combinations and decompositions needed for the library processing. To generate and verify the proposed flow and methodologies, a prototype for a placement-aware DP-ready cell-library is developed with an optimized number of cell views.

  7. The effect of foveal and parafoveal masks on the eye movements of older and younger readers.

    PubMed

    Rayner, Keith; Yang, Jinmian; Schuett, Susanne; Slattery, Timothy J

    2014-06-01

    In the present study, we examined foveal and parafoveal processing in older compared with younger readers by using gaze-contingent paradigms with 4 conditions. Older and younger readers read sentences in which the text was either a) presented normally, b) the foveal word was masked as soon as it was fixated, c) all of the words to the left of the fixated word were masked, or d) all of the words to the right of the fixated word were masked. Although older and younger readers both found reading when the fixated word was masked quite difficult, the foveal mask increased sentence reading time more than 3-fold (3.4) for the older readers (in comparison with the control condition in which the sentence was presented normally) compared with the younger readers who took 1.3 times longer to read sentences in the foveal mask condition (in comparison with the control condition). The left and right parafoveal masks did not disrupt reading as severely as the foveal mask, though the right mask was more disruptive than the left mask. Also, there was some indication that the younger readers found the right mask condition relatively more disruptive than the left mask condition. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  8. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers

    PubMed Central

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-01-01

    Objective The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. Setting 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. Participants 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Intervention Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Main outcome measure Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. Results The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. Conclusions This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Trial registration number Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. PMID:25903751

  9. Disposable surgical face masks for preventing surgical wound infection in clean surgery.

    PubMed

    Lipp, Allyson; Edwards, Peggy

    2014-02-17

    Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. We searched The Cochrane Wounds Group Specialised Register on 23 October 2013; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  10. Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial.

    PubMed

    Neuzeret, Pierre-Charles; Morin, Laurent

    2017-11-01

    Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest ® , HC407 ® or Philips EasyLife ® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP. © 2016 ResMed Germany Inc. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  11. Optical double-slit particle measuring system

    DOEpatents

    Tichenor, D.A.; Wang, J.C.F.; Hencken, K.R.

    1982-03-25

    A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3..mu..m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.

  12. Optical double-slit particle measuring system

    DOEpatents

    Hencken, Kenneth R.; Tichenor, Daniel A.; Wang, James C. F.

    1984-01-01

    A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3 .mu.m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.

  13. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.

    PubMed

    Ng, Justin R; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G; Chai-Coetzer, Ching Li; McEvoy, R Doug; Antic, Nick

    2016-09-15

    The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  14. Clean induced feature CD shift of EUV mask

    NASA Astrophysics Data System (ADS)

    Nesládek, Pavel; Schedel, Thorsten; Bender, Markus

    2016-05-01

    EUV developed in the last decade to the most promising <7nm technology candidate. Defects are considered to be one of the most critical issues of the EUV mask. There are several contributors which make the EUV mask so different from the optical one. First one is the significantly more complicated mask stack consisting currently of 40 Mo/Si double layers, covered by Ru capping layer and TaN/TaO absorber/anti-reflective coating on top of the front face of the mask. Backside is in contrary to optical mask covered as well by conductive layer consisting of Cr or CrN. Second contributor is the fact that EUV mask is currently in contrary to optical mask not yet equipped with sealed pellicle, leading to much higher risk of mask contamination. Third reason is use of EUV mask in vacuum, possibly leading to deposition of vacuum contaminants on the EUV mask surface. Latter reason in combination with tight requirements on backside cleanliness lead to the request of frequent recleaning of the EUV mask, in order to sustain mask lifetime similar to that of optical mask. Mask cleaning process alters slightly the surface of any mask - binary COG mask, as well as phase shift mask of any type and naturally also of the EUV mask as well. In case of optical masks the changes are almost negligible, as the mask is exposed to max. 10-20 re-cleans within its life time. These modifications can be expressed in terms of different specified parameters, e.g. CD shift, phase/trans shift, change of the surface roughness etc. The CD shift, expressed as thinning (or exceptionally thickening) of the dark features on the mask is typically in order of magnitude 0.1nm per process run, which is completely acceptable for optical mask. Projected on the lifetime of EUV mask, assuming 100 clean process cycles, this will lead to CD change of about 10nm. For this reason the requirements for EUV mask cleaning are significantly tighter, << 0.1 nm per process run. This task will look even more challenging, when considering, that the tools for CD measurement at the EUV mask are identical as for optical mask. There is one aspect influencing the CD shift, which demands attention. The mask composition of the EUV mask is significantly different from the optical mask. More precisely there are 2 materials influencing the estimated CD in case of EUV mask, whereas there is one material only in case of optical masks, in first approximation. For optical masks, the CD changes can be attributed to modification of the absorber/ARC layer, as the quartz substrate can be hardly modified by the wet process. For EUV Masks chemical modification of the Ru capping layer - thinning, oxidization etc. are rather more probable and we need to take into account, how this effects can influence the CD measurement process. CD changes measured can be interpreted as either change in the feature size, or modification of the chemical nature of both absorber/ARC layer stack and the Ru capping layer. In our work we try to separate the effect of absorber and Ru/capping layer on the CD shift observed and propose independent way of estimation both parameters.

  15. Schizophrenia alters intra-network functional connectivity in the caudate for detecting speech under informational speech masking conditions.

    PubMed

    Zheng, Yingjun; Wu, Chao; Li, Juanhua; Li, Ruikeng; Peng, Hongjun; She, Shenglin; Ning, Yuping; Li, Liang

    2018-04-04

    Speech recognition under noisy "cocktail-party" environments involves multiple perceptual/cognitive processes, including target detection, selective attention, irrelevant signal inhibition, sensory/working memory, and speech production. Compared to health listeners, people with schizophrenia are more vulnerable to masking stimuli and perform worse in speech recognition under speech-on-speech masking conditions. Although the schizophrenia-related speech-recognition impairment under "cocktail-party" conditions is associated with deficits of various perceptual/cognitive processes, it is crucial to know whether the brain substrates critically underlying speech detection against informational speech masking are impaired in people with schizophrenia. Using functional magnetic resonance imaging (fMRI), this study investigated differences between people with schizophrenia (n = 19, mean age = 33 ± 10 years) and their matched healthy controls (n = 15, mean age = 30 ± 9 years) in intra-network functional connectivity (FC) specifically associated with target-speech detection under speech-on-speech-masking conditions. The target-speech detection performance under the speech-on-speech-masking condition in participants with schizophrenia was significantly worse than that in matched healthy participants (healthy controls). Moreover, in healthy controls, but not participants with schizophrenia, the strength of intra-network FC within the bilateral caudate was positively correlated with the speech-detection performance under the speech-masking conditions. Compared to controls, patients showed altered spatial activity pattern and decreased intra-network FC in the caudate. In people with schizophrenia, the declined speech-detection performance under speech-on-speech masking conditions is associated with reduced intra-caudate functional connectivity, which normally contributes to detecting target speech against speech masking via its functions of suppressing masking-speech signals.

  16. Respiratory Source Control Using Surgical Masks With Nanofiber Media

    PubMed Central

    Skaria, Shaji D.; Smaldone, Gerald C.

    2014-01-01

    Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Conclusions: Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. PMID:24737728

  17. Respiratory source control using surgical masks with nanofiber media.

    PubMed

    Skaria, Shaji D; Smaldone, Gerald C

    2014-07-01

    Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  18. Devil's vortex Fresnel lens phase masks on an asymmetric cryptosystem based on phase-truncation in gyrator wavelet transform domain

    NASA Astrophysics Data System (ADS)

    Singh, Hukum

    2016-06-01

    An asymmetric scheme has been proposed for optical double images encryption in the gyrator wavelet transform (GWT) domain. Grayscale and binary images are encrypted separately using double random phase encoding (DRPE) in the GWT domain. Phase masks based on devil's vortex Fresnel Lens (DVFLs) and random phase masks (RPMs) are jointly used in spatial as well as in the Fourier plane. The images to be encrypted are first gyrator transformed and then single-level discrete wavelet transformed (DWT) to decompose LL , HL , LH and HH matrices of approximation, horizontal, vertical and diagonal coefficients. The resulting coefficients from the DWT are multiplied by other RPMs and the results are applied to inverse discrete wavelet transform (IDWT) for obtaining the encrypted images. The images are recovered from their corresponding encrypted images by using the correct parameters of the GWT, DVFL and its digital implementation has been performed using MATLAB 7.6.0 (R2008a). The mother wavelet family, DVFL and gyrator transform orders associated with the GWT are extra keys that cause difficulty to an attacker. Thus, the scheme is more secure as compared to conventional techniques. The efficacy of the proposed scheme is verified by computing mean-squared-error (MSE) between recovered and the original images. The sensitivity of the proposed scheme is verified with encryption parameters and noise attacks.

  19. Study and treatment of post Lyme disease (STOP-LD): a randomized double masked clinical trial.

    PubMed

    Krupp, L B; Hyman, L G; Grimson, R; Coyle, P K; Melville, P; Ahnn, S; Dattwyler, R; Chandler, B

    2003-06-24

    To determine whether post Lyme syndrome (PLS) is antibiotic responsive. The authors conducted a single-center randomized double-masked placebo-controlled trial on 55 patients with Lyme disease with persistent severe fatigue at least 6 or more months after antibiotic therapy. Patients were randomly assigned to receive 28 days of IV ceftriaxone or placebo. The primary clinical outcomes were improvement in fatigue, defined by a change of 0.7 points or more on an 11-item fatigue questionnaire, and improvement in cognitive function (mental speed), defined by a change of 25% or more on a test of reaction time. The primary laboratory outcome was an experimental measure of CSF infection, outer surface protein A (OspA). Outcome data were collected at the 6-month visit. Patients assigned to ceftriaxone showed improvement in disabling fatigue compared to the placebo group (rate ratio, 3.5; 95% CI, 1.50 to 8.03; p = 0.001). No beneficial treatment effect was observed for cognitive function or the laboratory measure of persistent infection. Four patients, three of whom were on placebo, had adverse events associated with treatment, which required hospitalization. Ceftriaxone therapy in patients with PLS with severe fatigue was associated with an improvement in fatigue but not with cognitive function or an experimental laboratory measure of infection in this study. Because fatigue (a nonspecific symptom) was the only outcome that improved and because treatment was associated with adverse events, this study does not support the use of additional antibiotic therapy with parenteral ceftriaxone in post-treatment, persistently fatigued patients with PLS.

  20. A novel anti-influenza copper oxide containing respiratory face mask.

    PubMed

    Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey

    2010-06-25

    Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10)TCID(50)), while 4.67+/-1.35 log(10)TCID(50) were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10)TCID(50) and from the control masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks.

  1. The extended functional neuroanatomy of emotional processing biases for masked faces in major depressive disorder.

    PubMed

    Victor, Teresa A; Furey, Maura L; Fromm, Stephen J; Bellgowan, Patrick S F; Öhman, Arne; Drevets, Wayne C

    2012-01-01

    Major depressive disorder (MDD) is associated with a mood-congruent processing bias in the amygdala toward face stimuli portraying sad expressions that is evident even when such stimuli are presented below the level of conscious awareness. The extended functional anatomical network that maintains this response bias has not been established, however. To identify neural network differences in the hemodynamic response to implicitly presented facial expressions between depressed and healthy control participants. Unmedicated-depressed participants with MDD (n=22) and healthy controls (HC; n=25) underwent functional MRI as they viewed face stimuli showing sad, happy or neutral face expressions, presented using a backward masking design. The blood-oxygen-level dependent (BOLD) signal was measured to identify regions where the hemodynamic response to the emotionally valenced stimuli differed between groups. The MDD subjects showed greater BOLD responses than the controls to masked-sad versus masked-happy faces in the hippocampus, amygdala and anterior inferotemporal cortex. While viewing both masked-sad and masked-happy faces relative to masked-neutral faces, the depressed subjects showed greater hemodynamic responses than the controls in a network that included the medial and orbital prefrontal cortices and anterior temporal cortex. Depressed and healthy participants showed distinct hemodynamic responses to masked-sad and masked-happy faces in neural circuits known to support the processing of emotionally valenced stimuli and to integrate the sensory and visceromotor aspects of emotional behavior. Altered function within these networks in MDD may establish and maintain illness-associated differences in the salience of sensory/social stimuli, such that attention is biased toward negative and away from positive stimuli.

  2. Metacontrast masking and attention do not interact.

    PubMed

    Agaoglu, Sevda; Breitmeyer, Bruno; Ogmen, Haluk

    2016-07-01

    Visual masking and attention have been known to control the transfer of information from sensory memory to visual short-term memory. A natural question is whether these processes operate independently or interact. Recent evidence suggests that studies that reported interactions between masking and attention suffered from ceiling and/or floor effects. The objective of the present study was to investigate whether metacontrast masking and attention interact by using an experimental design in which saturation effects are avoided. We asked observers to report the orientation of a target bar randomly selected from a display containing either two or six bars. The mask was a ring that surrounded the target bar. Attentional load was controlled by set-size and masking strength by the stimulus onset asynchrony between the target bar and the mask ring. We investigated interactions between masking and attention by analyzing two different aspects of performance: (i) the mean absolute response errors and (ii) the distribution of signed response errors. Our results show that attention affects observers' performance without interacting with masking. Statistical modeling of response errors suggests that attention and metacontrast masking exert their effects by independently modulating the probability of "guessing" behavior. Implications of our findings for models of attention are discussed.

  3. Polarization masks: concept and initial assessment

    NASA Astrophysics Data System (ADS)

    Lam, Michael; Neureuther, Andrew R.

    2002-07-01

    Polarization from photomasks can be used as a new lever to improve lithographic performance in both binary and phase-shifting masks (PSMs). While PSMs manipulate the phase of light to control the temporal addition of electric field vectors, polarization masks manipulate the vector direction of electric field vectors to control the spatial addition of electric field components. This paper explores the theoretical possibilities of polarization masks, showing that it is possible to use bar structures within openings on the mask itself to polarize incident radiation. Rigorous electromagnetic scattering simulations using TEMPEST and imaging with SPLAT are used to give an initial assessment on the functionality of polarization masks, discussing the polarization quality and throughputs achieved with the masks. Openings between 1/8 and 1/3 of a wavelength provide both a low polarization ratio and good transmission. A final overall throughput of 33% - 40% is achievable, corresponding to a dose hit of 2.5x - 3x.

  4. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers.

    PubMed

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-04-22

    The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series

    PubMed Central

    Ng, Justin R.; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G.; Chai-Coetzer, Ching Li; McEvoy, R. Doug; Antic, Nick

    2016-01-01

    Study Objectives: The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. Methods: We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. Results: The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m2) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. Conclusions: If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Ng JR, Aiyappan V, Mercer J, Catcheside PG, Chai-Coetzer CL, McEvoy RD, Antic N. Choosing an oronasal mask to deliver continuous positive airway pressure may cause more upper airway obstruction or lead to higher continuous positive airway pressure requirements than a nasal mask in some patients: a case series. J Clin Sleep Med 2016;12(9):1227–1232. PMID:27306398

  6. Specialization of the auditory processing in harbor porpoise, characterized by brain-stem potentials

    NASA Astrophysics Data System (ADS)

    Bibikov, Nikolay G.

    2002-05-01

    Brain-stem auditory evoked potentials (BAEPs) were recorded from the head surface of the three awaked harbor porpoises (Phocoena phocoena). Silver disk placed on the skin surface above the vertex bone was used as an active electrode. The experiments were performed at the Karadag biological station (the Crimea peninsula). Clicks and tone bursts were used as stimuli. The temporal and frequency selectivity of the auditory system was estimated using the methods of simultaneous and forward masking. An evident minimum of the BAEPs thresholds was observed in the range of 125-135 kHz, where the main spectral component of species-specific echolocation signal is located. In this frequency range the tonal forward masking demonstrated a strong frequency selectivity. Off-response to such tone bursts was a typical observation. An evident BAEP could be recorded up to the frequencies 190-200 kHz, however, outside the acoustical fovea the frequency selectivity was rather poor. Temporal resolution was estimated by measuring BAER recovery functions for double clicks, double tone bursts, and double noise bursts. The half-time of BAERs recovery was in the range of 0.1-0.2 ms. The data indicate that the porpoise auditory system is strongly adapted to detect ultrasonic closely spaced sounds like species-specific locating signals and echoes.

  7. Social learning spreads knowledge about dangerous humans among American crows

    PubMed Central

    Cornell, Heather N.; Marzluff, John M.; Pecoraro, Shannon

    2012-01-01

    Individuals face evolutionary trade-offs between the acquisition of costly but accurate information gained firsthand and the use of inexpensive but possibly less reliable social information. American crows (Corvus brachyrhynchos) use both sources of information to learn the facial features of a dangerous person. We exposed wild crows to a novel ‘dangerous face’ by wearing a unique mask as we trapped, banded and released 7–15 birds at five study sites near Seattle, WA, USA. An immediate scolding response to the dangerous mask after trapping by previously captured crows demonstrates individual learning, while an immediate response by crows that were not captured probably represents conditioning to the trapping scene by the mob of birds that assembled during the capture. Later recognition of dangerous masks by lone crows that were never captured is consistent with horizontal social learning. Independent scolding by young crows, whose parents had conditioned them to scold the dangerous mask, demonstrates vertical social learning. Crows that directly experienced trapping later discriminated among dangerous and neutral masks more precisely than did crows that learned through social means. Learning enabled scolding to double in frequency and spread at least 1.2 km from the place of origin over a 5 year period at one site. PMID:21715408

  8. Left ventricular mass of persistent masked hypertension in Hong Kong Chinese adolescents: a 4-year follow-up study.

    PubMed

    Yam, Man-Ching; So, Hung-Kwan; Kwok, Sit-Yee; Lo, Fung-Cheung; Mok, Chi-Fung; Leung, Chuk-Kwan; Yip, Wai-Kwok; Sung, Yn-Tz

    2018-06-01

    In our previous study, the prevalence of childhood masked hypertension was 11%. This study aims to assess the left ventricular mass index of persistent masked hypertension and determine the factors of elevated left ventricular mass index in Hong Kong Chinese adolescents from a community cohort. Community prospective cohort study, follow-up of a case-control study in community. Patients with masked hypertension at baseline were invited to recheck ambulatory blood pressure for the persistence of masked hypertension. A total of 144 out of 165 patients with masked hypertension in the 2011/2012 ambulatory blood pressure survey consented to participate in the study. In all, 48 patients were found to have persistent masked hypertension by ambulatory blood pressure rechecking and were matched with normotensive controls by sex, age, and body height. The left ventricular mass (117.3±39.9 g versus 87.0±28.2 g versus 102.0±28.2 g) and left ventricular mass index (30.1±8.4 g/m2.7 versus 23.9±6.3 g/m2.7 versus 25.1±5.7 g/m2.7) were significantly higher in the persistent masked hypertension group (p<0.0001) compared with the patients without persistent masked hypertension and controls. In multivariate linear regression analysis, left ventricular mass index was found to be higher in male gender (β=4.874, p<0.0001) and the patients with persistent masked hypertension (β=2.796, p=0.003). In addition, left ventricular mass index was positively associated with body mass index z-score (β=3.045, p<0.0001) and low-density lipoprotein cholesterol concentration (β=1.634, p=0.015). Persistent masked hypertension in adolescents is associated with elevated left ventricular mass index.

  9. Mask etcher data strategy for 45nm and beyond

    NASA Astrophysics Data System (ADS)

    Lewington, Richard; Ibrahim, Ibrahim M.; Panayil, Sheeba; Kumar, Ajay; Yamartino, John

    2006-05-01

    Mask Etching for the 45nm technology node and beyond requires a system-level data and diagnostics strategy. This necessity stems from the need to control the performance of the mask etcher to increasingly stringent and diverse requirements of the mask production environment. Increasing mask costs and the capability to acquire and consolidate a wealth of data within the mask etch platform are primary motivators towards harnessing data mines for feedback into the mask etching optimization. There are offline and real-time possibilities and scenarios. Here, we discuss the data architecture, acquisition, and strategies of the Applied Materials Tetra II TM Mask Etch System.

  10. A multicentre, double-masked, randomized, controlled trial assessing the effect of oral supplementation of omega-3 and omega-6 fatty acids on a conjunctival inflammatory marker in dry eye patients.

    PubMed

    Brignole-Baudouin, Françoise; Baudouin, Christophe; Aragona, Pasquale; Rolando, Maurizio; Labetoulle, Marc; Pisella, Pierre Jean; Barabino, Stefano; Siou-Mermet, Raphaele; Creuzot-Garcher, Catherine

    2011-11-01

    To determine whether oral supplementation with omega-3 and omega-6 fatty acids can reduce conjunctival epithelium expression of the inflammatory marker human leucocyte antigen-DR (HLA-DR) in patients with dry eye syndrome (DES). This 3-month, double-masked, parallel-group, controlled study was conducted in nine centres, in France and Italy. Eligible adult patients with mild to moderate DES were randomized to receive a placebo containing medium-chain triglycerides or treatment supplement containing omega-3 and omega-6 fatty acids, vitamins and zinc. Treatment regimen was three capsules daily. Impression cytology (IC) was performed at baseline and at month 3 to assess the percentage of cells expressing HLA-DR and to evaluate fluorescence intensity, an alternate measure of HLA-DR. Dry eye symptoms and objective signs were also evaluated. Analyses were performed on the full analysis set (FAS) and per-protocol set (PPS). In total, 138 patients were randomized; 121 patients with available IC were included in the FAS, and of these, 106 patients had no major protocol deviations (PPS). In the PPS, there was a significant reduction in the percentage of HLA-DR-positive cells in the fatty acids group (p = 0.021). Expression of HLA-DR as measured by fluorescence intensity quantification was also significantly reduced in the fatty acids group [FAS (p = 0.041); PPS (p = 0.017)]. No significant difference was found for the signs and symptoms, but there was a tendency for improvement in patients receiving the fatty acids treatment. This study demonstrates that supplementation with omega-3 and omega-6 fatty acids can reduce expression of HLA-DR conjunctival inflammatory marker and may help improve DES symptoms. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  11. A Randomized, Placebo Controlled, Double Masked Phase IB Study Evaluating the Safety and Antiviral Activity of Aprepitant, a Neurokinin-1 Receptor Antagonist in HIV-1 Infected Adults

    PubMed Central

    Tebas, Pablo; Tuluc, Florin; Barrett, Jeffrey S.; Wagner, Wayne; Kim, Deborah; Zhao, Huaquing; Gonin, René; Korelitz, James; Douglas, Steven D.

    2011-01-01

    Background Neurokinin-1 receptor (NK1R) antagonists have anti-HIV activity in monocyte-derived macrophages, decrease CCR5 expression and improve natural killer cell function ex vivo. Aprepitant is a NK1R antagonist approved by FDA as an antiemetic. Methods We conducted a phase IB randomized, placebo controlled, double masked study to evaluate the safety, antiviral activity, pharmacokinetics and immune-modulatory effects of aprepitant in HIV-infected adults not receiving antiretroviral therapy, with CD4+ cell count ≥350 cells/mm3 and plasma viral load ≥2,000 copies/ml. Subjects were stratified by viral load (< vs. ≥20,000 copies/ml) and randomized within each stratum to receive aprepitant at 125 mg QD(Low), or 250 mg QD(High), or placebo(PL) for 14 days, and followed for 42 days. Results Thirty subjects were randomized and 27 completed treatment (9, 8, 10 subjects in 125 (Low), 250 (High), and PL groups). 63% were male; 37% white; mean (SD) age 43 (9.3) years. Geometric mean baseline viral load (copies/ml) for Low, High, and PL was 15,709, 33,013, and 19,450, respectively. Mean (95%CI) change in log10 viral load at day 14 for Low, High, and PL was −0.02(−0.24,+0.20), −0.05(−0.21,+0.10), and +0.04(−0.08,+0.16), respectively. The number of subjects with AEs was 4(44.4%), 5(62.5%), and 1(10%) for Low, High, and PL. No Grade 4 AEs occurred. Conclusions Adverse events of aprepitant were more common in the treated groups. At the dose used in this two-week phase IB study, aprepitant showed biological activity, but no significant antiviral activity. Trial Registration ClinicalTrials.gov NCT00428519 PMID:21931661

  12. Is consciousness necessary for conflict detection and conflict resolution?

    PubMed

    Xiang, Ling; Wang, Baoxi; Zhang, Qinglin

    2013-06-15

    Is conflict control dependent on consciousness? To answer this question, we used high temporal resolution event-related potentials (ERPs) to separate conflict detection from conflict resolution in a masked prime Stroop task. Although behavioral interference effect was present in both the masked and unmasked conditions, the electrophysiological findings revealed more complex patterns. ERP analyses showed that N450 was greater for incongruent trials than for congruent trials and that it was located in the ACC and nearby motor cortex, regardless of whether the primes were masked or unmasked; however, the effects were smaller for the masked than unmasked condition. These results suggest that consciousness of conflict information may not be necessary for detecting conflict, but that it may modulate conflict detection. The analysis of slow potential (SP) amplitude showed that it distinguished incongruent trials from congruent trials, and that this modulation effects was reduced to a greater extent for the masked condition than for the unmasked condition. Moreover, the prefrontal-parietal control network was activated under the unmasked but not under the masked condition. These results suggest that the consciousness of conflict information may be a necessary boundary condition for the subsequent initiation of control operations in the more extended PFC-parietal control network. However, considering that the conflict interference effect was significantly reduced in the masked condition, it may be that, with larger unconscious conflict effects, more extensive cognitive control networks would have been activated. These findings have important implications for theories on the relationship between consciousness and cognitive control. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Rule of Thumb Proposing the Size of Aperture Expected to be Sufficient to Resolve Double Stars with Given Parameters

    NASA Astrophysics Data System (ADS)

    Knapp, Wilfried

    2018-01-01

    Visual observation of double stars is an anachronistic passion especially attractive for amateurs looking for sky objects suitable for visual observation even in light polluted areas. Session planning then requires a basic idea which objects might be suitable for a given equipment—this question is a long term issue for visual double star observers and obviously not easy to answer, especially for unequal bright components. Based on a reasonably large database with limited aperture observations (done with variable aperture equipment iris diaphragm or aperture masks) a heuristic approach is used to derive a statistically well founded Rule of Thumb formula.

  14. Dynamics of normalization underlying masking in human visual cortex.

    PubMed

    Tsai, Jeffrey J; Wade, Alex R; Norcia, Anthony M

    2012-02-22

    Stimulus visibility can be reduced by other stimuli that overlap the same region of visual space, a process known as masking. Here we studied the neural mechanisms of masking in humans using source-imaged steady state visual evoked potentials and frequency-domain analysis over a wide range of relative stimulus strengths of test and mask stimuli. Test and mask stimuli were tagged with distinct temporal frequencies and we quantified spectral response components associated with the individual stimuli (self terms) and responses due to interaction between stimuli (intermodulation terms). In early visual cortex, masking alters the self terms in a manner consistent with a reduction of input contrast. We also identify a novel signature of masking: a robust intermodulation term that peaks when the test and mask stimuli have equal contrast and disappears when they are widely different. We fit all of our data simultaneously with family of a divisive gain control models that differed only in their dynamics. Models with either very short or very long temporal integration constants for the gain pool performed worse than a model with an integration time of ∼30 ms. Finally, the absolute magnitudes of the response were controlled by the ratio of the stimulus contrasts, not their absolute values. This contrast-contrast invariance suggests that many neurons in early visual cortex code relative rather than absolute contrast. Together, these results provide a more complete description of masking within the normalization framework of contrast gain control and suggest that contrast normalization accomplishes multiple functional goals.

  15. Effect of preoperative oral midazolam sedation on separation anxiety and emergence delirium among children undergoing dental treatment under general anesthesia

    PubMed Central

    El Batawi, Hisham Yehia

    2015-01-01

    Aim: To investigate the possible effects of preoperative oral Midazolam on parental separation anxiety, emergence delirium, and post-anesthesia care unit time on children undergoing dental rehabilitation under general anesthesia. Methods: Randomized, prospective, double-blind study. Seventy-eight American Society of Anesthesiology (ASA) I children were divided into two groups of 39 each. Children of the first group were premedicated with oral Midazolam 0.5 mg/kg, while children of the control group were premedicated with a placebo. Scores for parental separation, mask acceptance, postoperative emergence delirium, and time spent in the post-anesthesia care unit were compared statistically. Results: The test group showed significantly lower parental separation scores and high acceptance rate for anesthetic mask. There was no significant difference between the two groups regarding emergence delirium and time spent in post-anesthesia care unit. Conclusions: Preoperative oral Midazolam could be a useful adjunct in anxiety management for children suffering dental anxiety. The drug may not reduce the incidence of postoperative emergence delirium. The suggested dose does not seem to affect the post-anesthesia care unit time. PMID:25992332

  16. Model-based virtual VSB mask writer verification for efficient mask error checking and optimization prior to MDP

    NASA Astrophysics Data System (ADS)

    Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong

    2014-10-01

    A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.

  17. Method for ultrafast optical deflection enabling optical recording via serrated or graded light illumination

    DOEpatents

    Heebner, John E [Livermore, CA

    2009-09-08

    In one general embodiment, a method for deflecting an optical signal input into a waveguide is provided. In operation, an optical input signal is propagated through a waveguide. Additionally, an optical control signal is applied to a mask positioned relative to the waveguide such that the application of the optical control signal to the mask is used to influence the optical input signal propagating in the waveguide. Furthermore, the deflected optical input signal output from the waveguide is detected in parallel on an array of detectors. In another general embodiment, a beam deflecting structure is provided for deflecting an optical signal input into a waveguide, the structure comprising at least one wave guiding layer for guiding an optical input signal and at least one masking layer including a pattern configured to influence characteristics of a material of the guiding layer when an optical control signal is passed through the masking layer in a direction of the guiding layer. In another general embodiment, a system is provided including a waveguide, an attenuating mask positioned on the waveguide, and an optical control source positioned to propagate pulsed laser light towards the attenuating mask and the waveguide such that a pattern of the attenuating mask is applied to the waveguide and material properties of at least a portion of the waveguide are influenced.

  18. A Novel Anti-Influenza Copper Oxide Containing Respiratory Face Mask

    PubMed Central

    Borkow, Gadi; Zhou, Steve S.; Page, Tom; Gabbay, Jeffrey

    2010-01-01

    Background Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. Methodology/Principal Findings We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66±0.51 and 6.17±0.37 log10TCID50 of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (≤0.88 log10TCID50), while 4.67±1.35 log10TCID50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were ≤0.97±0.01 log10TCID50 and from the control masks 5.03±0.54 log10TCID50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Conclusions/Significance Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks. PMID:20592763

  19. Is tinnitus an early voice of masked hypertension? High masked hypertension rate in patients with tinnitus.

    PubMed

    Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin

    2018-04-23

    Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.

  20. A New MRI Masking Technique Based on Multi-Atlas Brain Segmentation in Controls and Schizophrenia: A Rapid and Viable Alternative to Manual Masking.

    PubMed

    Del Re, Elisabetta C; Gao, Yi; Eckbo, Ryan; Petryshen, Tracey L; Blokland, Gabriëlla A M; Seidman, Larry J; Konishi, Jun; Goldstein, Jill M; McCarley, Robert W; Shenton, Martha E; Bouix, Sylvain

    2016-01-01

    Brain masking of MRI images separates brain from surrounding tissue and its accuracy is important for further imaging analyses. We implemented a new brain masking technique based on multi-atlas brain segmentation (MABS) and compared MABS to masks generated using FreeSurfer (FS; version 5.3), Brain Extraction Tool (BET), and Brainwash, using manually defined masks (MM) as the gold standard. We further determined the effect of different masking techniques on cortical and subcortical volumes generated by FreeSurfer. Images were acquired on a 3-Tesla MR Echospeed system General Electric scanner on five control and five schizophrenia subjects matched on age, sex, and IQ. Automated masks were generated from MABS, FS, BET, and Brainwash, and compared to MM using these metrics: a) volume difference from MM; b) Dice coefficients; and c) intraclass correlation coefficients. Mean volume difference between MM and MABS masks was significantly less than the difference between MM and FS or BET masks. Dice coefficient between MM and MABS was significantly higher than Dice coefficients between MM and FS, BET, or Brainwash. For subcortical and left cortical regions, MABS volumes were closer to MM volumes than were BET or FS volumes. For right cortical regions, MABS volumes were closer to MM volumes than were BET volumes. Brain masks generated using FreeSurfer, BET, and Brainwash are rapidly obtained, but are less accurate than manually defined masks. Masks generated using MABS, in contrast, resemble more closely the gold standard of manual masking, thereby offering a rapid and viable alternative. Copyright © 2015 by the American Society of Neuroimaging.

  1. Effects of alcohol and energy drink on mood and subjective intoxication: a double-blind, placebo-controlled, crossover study.

    PubMed

    Benson, Sarah; Scholey, Andrew

    2014-07-01

    There is concern that combining energy drinks with alcohol may 'mask' subjective intoxication leading to greater alcohol consumption. This study examines the effects of alcohol alone and combined with energy drink on objective and subjective intoxication and mood over the course of 3 h. Using a double-blind, placebo-controlled, balanced, crossover design, 24 participants (mean age 22.23 years) were administered with double placebo, 0.6 g/kg alcohol (mean peak blood alcohol content of 0.051%), 250 ml energy drink and alcohol/energy drink, according to a Latin square design, with a washout of >48 h. On each visit, they were breathalysed and rated themselves on a comprehensive battery of mood items at baseline and then at 45, 90 and 180 min post-drink. Blood alcohol and subjective intoxication were significantly increased following both alcohol alone and alcohol/energy drink. Both measures were statistically indistinguishable between alcohol conditions. In keeping with its (80 mg) caffeine content, the energy drink alone significantly increased self-rated 'alertness' and reduced 'depression-dejection' scores compared with the combined alcohol/energy drink. The alcohol/energy drink increased 'vigor' and 'contentment' at 45 min and decreased 'contentment' at 180 min. The co-ingestion of an energy drink with alcohol does not differently influence blood alcohol content recordings or subjective intoxication compared with alcohol alone, although some mood items are differentially affected. Copyright © 2014 John Wiley & Sons, Ltd.

  2. ALOX5 gene variants affect eicosanoid production and response to fish oil supplementation

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to determine whether 5-lipoxygenase (ALOX5) gene variants associated with cardiovascular disease affect eicosanoid production by monocytes. The study was a randomized, double-masked, parallel intervention trial with fish oil (5.0 g of fish oil daily, containing 2.0 g ...

  3. Hormonal regulators of muscle and metabolism in aging (HORMA): Design and conduct of a complex, double-masked, multicenter trial

    USDA-ARS?s Scientific Manuscript database

    BACKGROUND: Older persons often lose muscle mass, strength, and physical function. This report describes the challenges of conducting a complex clinical investigation assessing the effects of anabolic hormones on body composition, physical function, and metabolism during aging. METHODS: HORMA is a m...

  4. Bury my Face in Casting Plaster

    ERIC Educational Resources Information Center

    Judnick, Don

    1976-01-01

    As part of an introductory course in figure drawing, art students spent some time doing portrait studies and profile drawings. When the teacher threw in an ancedote on life masks, it had a double impact. Students learned to better understand underlying bone structure and facial planes and to create a new art product. (Author/RK)

  5. Topical anaesthetic and tear film stability.

    PubMed

    Mengher, L S; Pandher, K S; Bron, A J

    1986-02-01

    The effect of unpreserved topical anaesthetic on tear film stability (0.4% oxybuprocaine hydrochloride) was investigated in a double masked randomised study in 12 healthy volunteers, using a noninvasive tear film break up technique (NIBUT). It was found that the topical anaesthetic did not reduce the pre-corneal tear film stability, contrary to the electron microscopic evidence.

  6. Fabrication of a terahertz quantum-cascade laser with a double metal waveguide based on multilayer GaAs/AlGaAs heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khabibullin, R. A., E-mail: khabibullin@isvch.ru; Shchavruk, N. V.; Pavlov, A. Yu.

    2016-10-15

    The Postgrowth processing of GaAs/AlGaAs multilayer heterostructures for terahertz quantumcascade lasers (QCLs) are studied. This procedure includes the thermocompression bonding of In–Au multilayer heterostructures with a doped n{sup +}-GaAs substrate, mechanical grinding, and selective wet etching of the substrate, and dry etching of QCL ridge mesastripes through a Ti/Au metallization mask 50 and 100 μm wide. Reactive-ion-etching modes with an inductively coupled plasma source in a BCl{sub 3}/Ar gas mixture are selected to obtain vertical walls of the QCL ridge mesastripes with minimum Ti/Au mask sputtering.

  7. Disposable surgical face masks for preventing surgical wound infection in clean surgery.

    PubMed

    Vincent, Marina; Edwards, Peggy

    2016-04-26

    Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether the wearing of disposable surgical face masks by the surgical team during clean surgery reduces postoperative surgical wound infection. In December 2015, for this seventh update, we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials; Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched the bibliographies of all retrieved and relevant publications. There were no restrictions with respect to language, date of publication or study setting. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. We included three trials, involving a total of 2106 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. We identified no new trials for this latest update. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  8. Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.

    PubMed

    Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano

    2015-08-01

    To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. We report a prospective, randomized, parallel 1:1, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation. We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred. In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. Registered with ClinicalTrials.gov: NCT01963936. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Progress on EUV mask fabrication for 32-nm technology node and beyond

    NASA Astrophysics Data System (ADS)

    Zhang, Guojing; Yan, Pei-Yang; Liang, Ted; Park, Seh-jin; Sanchez, Peter; Shu, Emily Y.; Ultanir, Erdem A.; Henrichs, Sven; Stivers, Alan; Vandentop, Gilroy; Lieberman, Barry; Qu, Ping

    2007-05-01

    Extreme ultraviolet lithography (EUVL) tool development achieved a big milestone last year as two full-field Alpha Demo Tools (ADT) were shipped to customers by ASML. In the future horizon, a full field "EUV1" exposure tool from Nikon will be available by the end of 20071 and the pre-production EUV exposure tools from ASML are targeted for 20092. It is essential that high quality EUVL masks can be made and delivered to the EUVL tool users to support the technology development. In the past year, we have demonstrated mask fabrication with low stress absorber deposition and good etch process control yielding a vertical etch profile and a mask CD control of 5.7 nm for 32 nm (1x) space and 7.4 nm for 32 nm (1x) lines. Mask pattern resolution of 15 nm (1x) dense lines was achieved. Full field reflective mask die-to-die inspection at a 125nm pixel size was demonstrated after low defect multilayer blanks became available. In this paper, we will present details of the Intel EUVL Mask Pilot Line progress in EUVL mask defect reduction, pattern CD performance, program defect mask design and inspection, in-house absorber film development and its performance, and EUVL metrology tool development. We will demonstrate an overall improvement in EUV mask manufacturing readiness due to our Pilot Line activities.

  10. Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    NASA Technical Reports Server (NTRS)

    Newman, Kevin; Belikov, Ruslan; Pluzhnik, Eugene; Balasubramanian, Kunjithapatham; Wilson, Dan

    2014-01-01

    Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

  11. Lightweight Face Mask

    NASA Technical Reports Server (NTRS)

    Cason, W. E. I.; Baucom, R. M.; Evans, R. C.

    1982-01-01

    Lightweight face mask originally developed to protect epileptic patients during seizures could have many other medical and nonmedical applications such as muscular distrophy patients, football linesmen and riot-control police. Masks are extremely lightweight, the lightest of the configurations weighing only 136 grams.

  12. Less is More: Neural Activity During Very Brief and Clearly Visible Exposure to Phobic Stimuli

    PubMed Central

    Siegel, Paul; Warren, Richard; Wang, Zhishun; Yang, Jie; Cohen, Don; Anderson, Jason F.; Murray, Lilly; Peterson, Bradley S.

    2017-01-01

    Research on automatic processes in emotion has focused almost exclusively on the provocation of fear responses. We have shown, in contrast, that the repeated presentation of masked feared images reduces avoidance of a live tarantula by spider-phobic participants. We investigated the neural basis for these adaptive effects of masked exposure. We identified 21 spider-phobic and 21 control participants using a psychiatric interview, fear questionnaire, and approach behavior towards a live tarantula. They received each of three conditions: (1) very brief exposure (VBE) to masked images of spiders; (2) clearly visible exposure (CVE) to spiders; and (3) masked images of flowers (control). Only VBE to masked spiders generated neural activity more strongly in phobic than in control participants, within subcortical fear, attention, higher-order language, and vision systems. Counter-intuitively, CVE to the same spiders generated stronger neural activity in control rather than phobic participants within these and other systems. VBE activated regions that support fear processing in phobic participants without causing them to experience fear consciously. CVE, by contrast, deactivated regions supporting fear regulation and caused phobic participants to experience fear. Activations by CVE to spiders correlated with fear ratings - explicit fear. Activations by VBE to masked spiders correlated with color-naming interference of spider words – implicit fear. These multiple dissociations between the effects of VBE and CVE to spiders suggest that limiting awareness of exposure to phobic stimuli through visual masking paradoxically facilitates their processing, while simultaneously minimizing the experience of fear. PMID:28165171

  13. Jig Aligns Shadow Mask On CCD

    NASA Technical Reports Server (NTRS)

    Matus, Carlos V.

    1989-01-01

    Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

  14. Surgical face masks worn by patients with multidrug-resistant tuberculosis: impact on infectivity of air on a hospital ward.

    PubMed

    Dharmadhikari, Ashwin S; Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A; van der Walt, Martie; Nardell, Edward A

    2012-05-15

    Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68-85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31-51%), representing a 56% (95% CI, 33-70.5%) decreased risk of TB transmission when patients used masks. Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients.

  15. Effects of alcohol mixed with energy drink and alcohol alone on subjective intoxication.

    PubMed

    Ulbrich, Andrea; Hemberger, Sophie Helene; Loidl, Alexandra; Dufek, Stephanie; Pablik, Eleonore; Fodor, Sugarka; Herle, Marion; Aufricht, Christoph

    2013-12-01

    Recent studies suggest that the combination of caffeine-containing drinks together with alcohol might reduce the subjective feelings of alcohol intoxication-the so-called "masking effect". In this study, we aimed to review the effects of alcohol in combination with caffeine or energy drink with special focus on the "masking effect". Fifty-two healthy male volunteers were analysed concerning breath alcohol concentration and subjective sensations of intoxication using a 18 item Visual Analogue Scale in a randomised, double-blinded, controlled, four treatments cross-over trial after consumption of (A) placebo, (B) alcohol (vodka 37.5% at a dose of 46.5 g ethanol), (C) alcohol in combination with caffeine at a dose of 80 mg (equivalent to one 250 ml can of energy drink) and (D) alcohol in combination with energy drink at a dose of 250 ml (one can). Primary variables were headache, weakness, salivation and motor coordination. Out of four primary variables, weakness and motor coordination showed a statistically significant difference between alcohol and non-alcohol group, out of 14 secondary variables, five more variables (dizziness, alterations in sight, alterations in walking, agitation and alterations in speech) also showed significant differences due mainly to contrasts with the non-alcohol group. In none of these end points, could a statistically significant effect be found for the additional ingestion of energy drink or caffeine on the subjective feelings of alcohol intoxication. This within-subjects study does not confirm the presence of a "masking effect" when combining caffeine or energy drink with alcohol.

  16. A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers

    PubMed Central

    MacIntyre, Chandini Raina; Wang, Quanyi; Cauchemez, Simon; Seale, Holly; Dwyer, Dominic E.; Yang, Peng; Shi, Weixian; Gao, Zhanhai; Pang, Xinghuo; Zhang, Yi; Wang, Xiaoli; Duan, Wei; Rahman, Bayzidur; Ferguson, Neil

    2011-01-01

    Please cite this paper as: MacIntyre et al. (2011) A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers. Influenza and Other Respiratory Viruses DOI: 10.1111/j.1750‐2659.2010.00198.x. Background  We compared the efficacy of medical masks, N95 respirators (fit tested and non fit tested), in health care workers (HCWs). Methods  A cluster randomized clinical trial (RCT) of 1441 HCWs in 15 Beijing hospitals was performed during the 2008/2009 winter. Participants wore masks or respirators during the entire work shift for 4 weeks. Outcomes included clinical respiratory illness (CRI), influenza‐like illness (ILI), laboratory‐confirmed respiratory virus infection and influenza. A convenience no‐mask/respirator group of 481 health workers from nine hospitals was compared. Findings  The rates of CRI (3·9% versus 6·7%), ILI (0·3% versus 0·6%), laboratory‐confirmed respiratory virus (1·4% versus 2·6%) and influenza (0·3% versus 1%) infection were consistently lower for the N95 group compared to medical masks. By intention‐to‐treat analysis, when P values were adjusted for clustering, non‐fit‐tested N95 respirators were significantly more protective than medical masks against CRI, but no other outcomes were significant. The rates of all outcomes were higher in the convenience no‐mask group compared to the intervention arms. There was no significant difference in outcomes between the N95 arms with and without fit testing. Rates of fit test failure were low. In a post hoc analysis adjusted for potential confounders, N95 masks and hospital level were significant, but medical masks, vaccination, handwashing and high‐risk procedures were not. Interpretation  Rates of infection in the medical mask group were double that in the N95 group. A benefit of respirators is suggested but would need to be confirmed by a larger trial, as this study may have been underpowered. The finding on fit testing is specific to the type of respirator used in the study and cannot be generalized to other respirators. Trial registration  Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN: ACTRN12609000257268 (http://www.anzctr.org.au). PMID:21477136

  17. Exploring EUV and SAQP pattering schemes at 5nm technology node

    NASA Astrophysics Data System (ADS)

    Hamed Fatehy, Ahmed; Kotb, Rehab; Lafferty, Neal; Jiang, Fan; Word, James

    2018-03-01

    For years, Moore's law keeps driving the semiconductors industry towards smaller dimensions and higher density chips with more devices. Earlier, the correlation between exposure source's wave length and the smallest resolvable dimension, mandated the usage of Deep Ultra-Violent (DUV) optical lithography system which has been used for decades to sustain Moore's law, especially when immersion lithography was introduced with 193nm ArF laser sources. As dimensions of devices get smaller beyond Deep Ultra-Violent (DUV) optical resolution limits, the need for Extremely Ultra-Violent (EUV) optical lithography systems was a must. However, EUV systems were still under development at that time for the mass-production in semiconductors industry. Theretofore, Multi-Patterning (MP) technologies was introduced to swirl about DUV optical lithography limitations in advanced nodes beyond minimum dimension (CD) of 20nm. MP can be classified into two main categories; the first one is to split the target itself across multiple masks that give the original target patterns when they are printed. This category includes Double, Triple and Quadruple patterning (DP, TP, and QP). The second category is the Self-Aligned Patterning (SAP) where the target is divided into Mandrel patterns and non-Mandrel patterns. The Mandrel patterns get printed first, then a self-aligned sidewalls are grown around these printed patterns drawing the other non-Mandrel targets, afterword, a cut mask(s) is used to define target's line-ends. This approach contains Self-Aligned-Double Pattering (SADP) and Self-Aligned- Quadruple-Pattering (SAQP). DUV and MP along together paved the way for the industry down to 7nm. However, with the start of development at the 5nm node and the readiness of EUV, the differentiation question is aroused again, which pattering approach should be selected, direct printing using EUV or DUV with MP, or a hybrid flow that contains both DUV-MP and EUV. In this work we are comparing two potential pattering techniques for Back End Of Line (BEOL) metal layers in the 5nm technology node, the first technique is Single Exposure EUV (SE-EUV) with a Direct Patterning EUV lithography process, and the second one is Self-Aligned Quadruple Patterning (SAQP) with a hybrid lithography processes, where the drawn metal target layer is decomposed into a Mandrel mask and Blocks/Cut mask, Mandrel mask is printed using DUV 193i lithography process, while Block/Cut Mask is printed using SE-EUV lithography process. The pros and cons of each technique are quantified based on Edge-Placement-Error (EPE) and Process Variation Band (PVBand) measured at 1D and 2D edges. The layout used in this comparison is a candidate layout for Foundries 5nm process node.

  18. A multicentre phase III randomised controlled single-masked clinical trial evaluating the clinical efficacy and safety of light-masks at preventing dark-adaptation in the treatment of early diabetic macular oedema (CLEOPATRA): study protocol for a randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Arden, Geoffrey; Prevost, A Toby; Crosby-Nwaobi, Roxanne; Holmes, Helen; Kelly, Joanna; Murphy, Caroline; Rubin, Gary; Vasconcelos, Joanna; Hykin, Philip

    2014-11-22

    This study will evaluate hypoxia, as a novel concept in the pathogenesis of diabetic macular oedema (DMO). As the oxygen demand of the eye is maximum during dark-adaptation, we hypothesize that wearing light-masks during sleep will cause regression and prevent the development and progression of DMO. The study protocol comprises both an efficacy and mechanistic evaluation to test this hypothesis. This is a phase III randomised controlled single-masked multicentre clinical trial to test the clinical efficacy of light-masks at preventing dark-adaptation in the treatment of non-central DMO. Three hundred patients with non-centre-involving DMO in at least one eye will be randomised 1:1 to light-masks and control masks (with no light) to be used during sleep at night for a period of 24 months. The primary outcome is regression of non-central oedema by assessing change in the zone of maximal retinal thickness at baseline on optical coherence tomography (SD-OCT). Secondary outcomes will evaluate the prevention of development and progression of DMO by assessing changes in retinal thickness in different regions of the macula, macular volume, refracted visual acuity and level of retinopathy. Safety parameters will include sleep disturbance. Adverse events and measures of compliance will be assessed over 24 months. Participants recruited to the mechanistic sub-study will have additional retinal oximetry, multifocal electroretinography (ERG) and microperimetry to evaluate the role of hypoxia by assessing and comparing changes induced by supplemental oxygen and the light-masks at 12 months. The outcomes of this study will provide insight into the pathogenesis of DMO and provide evidence on whether a simple, non-invasive device in the form of a light-mask can help prevent the progression to centre-involving DMO and visual impairment in people with diabetes.

  19. Control superstructure of rigid polyelectrolytes in oppositely charged hydrogels via programmed internal stress

    NASA Astrophysics Data System (ADS)

    Takahashi, Riku; Wu, Zi Liang; Arifuzzaman, Md; Nonoyama, Takayuki; Nakajima, Tasuku; Kurokawa, Takayuki; Gong, Jian Ping

    2014-08-01

    Biomacromolecules usually form complex superstructures in natural biotissues, such as different alignments of collagen fibres in articular cartilages, for multifunctionalities. Inspired by nature, there are efforts towards developing multiscale ordered structures in hydrogels (recognized as one of the best candidates of soft biotissues). However, creating complex superstructures in gels are hardly realized because of the absence of effective approaches to control the localized molecular orientation. Here we introduce a method to create various superstructures of rigid polyanions in polycationic hydrogels. The control of localized orientation of rigid molecules, which are sensitive to the internal stress field of the gel, is achieved by tuning the swelling mismatch between masked and unmasked regions of the photolithographic patterned gel. Furthermore, we develop a double network structure to toughen the hydrogels with programmed superstructures, which deform reversibly under large strain. This work presents a promising pathway to develop superstructures in hydrogels and should shed light on designing biomimetic materials with intricate molecular alignments.

  20. Cardiac tamponade: new technology masking an old nemesis.

    PubMed

    Yates, Andrew R; Duffy, Victoria L; Clark, Tamara D; Hayes, Don; Tobias, Joseph D; McConnell, Patrick I; Preston, Thomas J

    2014-03-01

    A 16-year-old male patient underwent bilateral pulmonary embolectomy complicated by reperfusion injury and acute respiratory distress syndrome requiring venovenous extracorporeal membrane oxygenation support using a bicaval double-lumen catheter. A unique hemodynamic profile developed consistent with tamponade but without an associated decrease in venovenous extracorporeal membrane oxygenation pump flow, improved venovenous extracorporeal membrane oxygenation circuit preload, and decreased recirculation. The use of newer bicaval double-lumen catheters can result in old problems presenting in new ways and require clinicians to be ever vigilant. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Bandwidth-narrowed Bragg gratings inscribed in double-cladding fiber by femtosecond laser.

    PubMed

    Shi, Jiawei; Li, Yuhua; Liu, Shuhui; Wang, Haiyan; Liu, Ningliang; Lu, Peixiang

    2011-01-31

    Bragg gratings with the bandwidth(FWHM) narrowed up to 79 pm were inscribed in double-cladding fiber with femtosecond radiation and a phase mask followed by an annealing treatment. With the annealing temperature below a critical value, the bandwidth of Bragg gratings induced by Type I-IR and Type II-IR index change was narrowed without the reduction of reflectivity. The bandwidth narrowing is due to the profile transformation of the refractive index modulation caused by the annealing treatment. This mechanism was verified by comparing bandwidth narrowing processes of FBGs written with different power densities.

  2. Masking technique for coating thickness control on large and strongly curved aspherical optics.

    PubMed

    Sassolas, B; Flaminio, R; Franc, J; Michel, C; Montorio, J-L; Morgado, N; Pinard, L

    2009-07-01

    We discuss a method to control the coating thickness deposited onto large and strongly curved optics by ion beam sputtering. The technique uses an original design of the mask used to screen part of the sputtered materials. A first multielement mask is calculated from the measured two-dimensional coating thickness distribution. Then, by means of an iterative process, the final mask is designed. By using such a technique, it has been possible to deposit layers of tantalum pentoxide having a high thickness gradient onto a curved substrate 500 mm in diameter. Residual errors in the coating thickness profile are below 0.7%.

  3. Model of visual contrast gain control and pattern masking

    NASA Technical Reports Server (NTRS)

    Watson, A. B.; Solomon, J. A.

    1997-01-01

    We have implemented a model of contrast gain and control in human vision that incorporates a number of key features, including a contrast sensitivity function, multiple oriented bandpass channels, accelerating nonlinearities, and a devisive inhibitory gain control pool. The parameters of this model have been optimized through a fit to the recent data that describe masking of a Gabor function by cosine and Gabor masks [J. M. Foley, "Human luminance pattern mechanisms: masking experiments require a new model," J. Opt. Soc. Am. A 11, 1710 (1994)]. The model achieves a good fit to the data. We also demonstrate how the concept of recruitment may accommodate a variant of this model in which excitatory and inhibitory paths have a common accelerating nonlinearity, but which include multiple channels tuned to different levels of contrast.

  4. Irradiation resistance of intravolume shading elements embedded in photomasks used for CD uniformity control by local intra-field transmission attenuation

    NASA Astrophysics Data System (ADS)

    Zait, Eitan; Ben-Zvi, Guy; Dmitriev, Vladimir; Oshemkov, Sergey; Pforr, Rainer; Hennig, Mario

    2006-05-01

    Intra-field CD variation is, besides OPC errors, a main contributor to the total CD variation budget in IC manufacturing. It is caused mainly by mask CD errors. In advanced memory device manufacturing the minimum features are close to the resolution limit resulting in large mask error enhancement factors hence large intra-field CD variations. Consequently tight CD Control (CDC) of the mask features is required, which results in increasing significantly the cost of mask and hence the litho process costs. Alternatively there is a search for such techniques (1) which will allow improving the intrafield CD control for a given moderate mask and scanner imaging performance. Currently a new technique (2) has been proposed which is based on correcting the printed CD by applying shading elements generated in the substrate bulk of the mask by ultrashort pulsed laser exposure. The blank transmittance across a feature is controlled by changing the density of light scattering pixels. The technique has been demonstrated to be very successful in correcting intra-field CD variations caused by the mask and the projection system (2). A key application criterion of this technique in device manufacturing is the stability of the absorbing pixels against DUV light irradiation being applied during mask projection in scanners. This paper describes the procedures and results of such an investigation. To do it with acceptable effort a special experimental setup has been chosen allowing an evaluation within reasonable time. A 193nm excimer laser with pulse duration of 25 ns has been used for blank irradiation. Accumulated dose equivalent to 100,000 300 mm wafer exposures has been applied to Half Tone PSM mask areas with and without CDC shadowing elements. This allows the discrimination of effects appearing in treated and untreated glass regions. Several intensities have been investigated to define an acceptable threshold intensity to avoid glass compaction or generation of color centers in the glass. The impact of the irradiation on the mask transmittance of both areas has been studied by measurements of the printed CD on wafer using a wafer scanner before and after DUV irradiation.

  5. Flurbiprofen and intraocular pressure.

    PubMed

    Gieser, D K; Hodapp, E; Goldberg, I; Kass, M A; Becker, B

    1981-07-01

    Systemic or topical administration of corticosteroids may produce a rise in intraocular pressure (IOP). Nonsteroidal anti-inflammatory drugs (NSAI drugs) are alternate therapy for ocular inflammatory disease. Flurbiprofen, a new NSAI drug, was tested in double-masked fashion to delineate its effect on IOP. Flurbiprofen did not alter IOP in known high corticosteroid responders nor did it block corticosteroid-induced ocular hypertension.

  6. Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers

    NASA Astrophysics Data System (ADS)

    Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki

    2017-07-01

    Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.

  7. Challenges of anamorphic high-NA lithography and mask making

    NASA Astrophysics Data System (ADS)

    Hsu, Stephen D.; Liu, Jingjing

    2017-06-01

    Chip makers are actively working on the adoption of 0.33 numerical aperture (NA) EUV scanners for the 7-nm and 5-nm nodes (B. Turko, S. L. Carson, A. Lio, T. Liang, M. Phillips, et al., in `Proc. SPIE9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 977602 (2016) doi: 10.1117/12.2225014; A. Lio, in `Proc. SPIE9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 97760V (2016) doi: 10.1117/12.2225017). In the meantime, leading foundries and integrated device manufacturers are starting to investigate patterning options beyond the 5-nm node (O. Wood, S. Raghunathan, P. Mangat, V. Philipsen, V. Luong, et al., in `Proc. SPIE. 9422, Extreme Ultraviolet (EUV) Lithography VI', vol. 94220I (2015) doi: 10.1117/12.2085022). To minimize the cost and process complexity of multiple patterning beyond the 5-nm node, EUV high-NA single-exposure patterning is a preferred method over EUV double patterning (O. Wood, S. Raghunathan, P. Mangat, V. Philipsen, V. Luong, et al., in `Proc. SPIE. 9422, Extreme Ultraviolet (EUV) Lithography VI', vol. 94220I (2015) doi: 10.1117/12.2085022; J. van Schoot, K. van Ingen Schenau, G. Bottiglieri, K. Troost, J. Zimmerman, et al., `Proc. SPIE. 9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 97761I (2016) doi: 10.1117/12.2220150). The EUV high-NA scanner equipped with a projection lens of 0.55 NA is designed to support resolutions below 10 nm. The high-NA system is beneficial for enhancing resolution, minimizing mask proximity correction bias, improving normalized image log slope (NILS), and controlling CD uniformity (CDU). However, increasing NA from 0.33 to 0.55 reduces the depth of focus (DOF) significantly. Therefore, the source mask optimization (SMO) with sub-resolution assist features (SRAFs) are needed to increase DOF to meet the demanding full chip process control requirements (S. Hsu, R. Howell, J. Jia, H.-Y. Liu, K. Gronlund, et al., EUV `Proc. SPIE9048, Extreme Ultraviolet (EUV) Lithography VI', (2015) doi: 10.1117/12.2086074). To ensure no assist feature printing, the assist feature sizes need to be scaled with λ/NA. The extremely small SRAF width (below 25 nm on the reticle) is difficult to fabricate across the full reticle. In this paper, we introduce an innovative `attenuated SRAF' to improve SRAF manufacturability and still maintain the process window benefit. A new mask fabrication process is proposed to use existing mask-making capability to manufacture the attenuated SRAFs. The high-NA EUV system utilizes anamorphic reduction; 4× in the horizontal (slit) direction and 8× in the vertical (scanning) direction (J. van Schoot, K. van Ingen Schenau, G. Bottiglieri, K. Troost, J. Zimmerman, et al., `Proc. SPIE. 9776, Extreme Ultraviolet (EUV) Lithography VII', vol. 97761I (2016) doi: 10.1117/12.2220150; B. Kneer, S. Migura, W. Kaiser, J. T. Neumann, J. van Schoot, in `Proc. SPIE9422, Extreme Ultraviolet (EUV) Lithography VI', vol. 94221G (2015) doi: 10.1117/12.2175488). For an anamorphic system, the magnification has an angular dependency, and thus, familiar mask specifications such as mask error factor (MEF) need to be redefined. Similarly, mask-manufacturing rule check (MRC) needs to consider feature orientation.

  8. Method To Display Data On A Face Mask

    NASA Technical Reports Server (NTRS)

    Moore, Kevin-Duron

    1995-01-01

    Proposed electronic instrument displays information on diver's or firefighter's face mask. Includes mask, prism, electronic readouts, transceiver and control electronics. Mounted at periphery of diver's field of view to provide data on elapsed time, depth, pressure, and temperature. Provides greater safety and convenience to user.

  9. On the effectiveness of noise masks: naturalistic vs. un-naturalistic image statistics.

    PubMed

    Hansen, Bruce C; Hess, Robert F

    2012-05-01

    It has been argued that the human visual system is optimized for identification of broadband objects embedded in stimuli possessing orientation averaged power spectra fall-offs that obey the 1/f(β) relationship typically observed in natural scene imagery (i.e., β=2.0 on logarithmic axes). Here, we were interested in whether individual spatial channels leading to recognition are functionally optimized for narrowband targets when masked by noise possessing naturalistic image statistics (β=2.0). The current study therefore explores the impact of variable β noise masks on the identification of narrowband target stimuli ranging in spatial complexity, while simultaneously controlling for physical or perceived differences between the masks. The results show that β=2.0 noise masks produce the largest identification thresholds regardless of target complexity, and thus do not seem to yield functionally optimized channel processing. The differential masking effects are discussed in the context of contrast gain control. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Formal specification and verification of a fault-masking and transient-recovery model for digital flight-control systems

    NASA Technical Reports Server (NTRS)

    Rushby, John

    1991-01-01

    The formal specification and mechanically checked verification for a model of fault-masking and transient-recovery among the replicated computers of digital flight-control systems are presented. The verification establishes, subject to certain carefully stated assumptions, that faults among the component computers are masked so that commands sent to the actuators are the same as those that would be sent by a single computer that suffers no failures.

  11. Masks For Deposition Of Aspherical Optical Surfaces

    NASA Technical Reports Server (NTRS)

    Rogers, John R.; Martin, John D.

    1992-01-01

    Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

  12. The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence

    PubMed Central

    bin‐Reza, Faisal; Lopez Chavarrias, Vicente; Nicoll, Angus; Chamberland, Mary E.

    2011-01-01

    Please cite this paper as: bin‐Reza et al. (2012) The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence. Influenza and Other Respiratory Viruses 6(4), 257–267. There are limited data on the use of masks and respirators to reduce transmission of influenza. A systematic review was undertaken to help inform pandemic influenza guidance in the United Kingdom. The initial review was performed in November 2009 and updated in June 2010 and January 2011. Inclusion criteria included randomised controlled trials and quasi‐experimental and observational studies of humans published in English with an outcome of laboratory‐confirmed or clinically‐diagnosed influenza and other viral respiratory infections. There were 17 eligible studies. Six of eight randomised controlled trials found no significant differences between control and intervention groups (masks with or without hand hygiene; N95/P2 respirators). One household trial found that mask wearing coupled with hand sanitiser use reduced secondary transmission of upper respiratory infection/influenza‐like illness/laboratory‐confirmed influenza compared with education; hand sanitiser alone resulted in no reduction. One hospital‐based trial found a lower rate of clinical respiratory illness associated with non‐fit‐tested N95 respirator use compared with medical masks. Eight of nine retrospective observational studies found that mask and/or respirator use was independently associated with a reduced risk of severe acute respiratory syndrome (SARS). Findings, however, may not be applicable to influenza and many studies were suboptimal. None of the studies established a conclusive relationship between mask/respirator use and protection against influenza infection. Some evidence suggests that mask use is best undertaken as part of a package of personal protection especially hand hygiene. The effectiveness of masks and respirators is likely linked to early, consistent and correct usage. PMID:22188875

  13. Surgical Face Masks Worn by Patients with Multidrug-Resistant Tuberculosis

    PubMed Central

    Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A.; van der Walt, Martie; Nardell, Edward A.

    2012-01-01

    Rationale: Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. Objectives: We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Methods: Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Measurements and Main Results: Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68–85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31–51%), representing a 56% (95% CI, 33–70.5%) decreased risk of TB transmission when patients used masks. Conclusions: Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients. PMID:22323300

  14. Accurate defect die placement and nuisance defect reduction for reticle die-to-die inspections

    NASA Astrophysics Data System (ADS)

    Wen, Vincent; Huang, L. R.; Lin, C. J.; Tseng, Y. N.; Huang, W. H.; Tuo, Laurent C.; Wylie, Mark; Chen, Ellison; Wang, Elvik; Glasser, Joshua; Kelkar, Amrish; Wu, David

    2015-10-01

    Die-to-die reticle inspections are among the simplest and most sensitive reticle inspections because of the use of an identical-design neighboring-die for the reference image. However, this inspection mode can have two key disadvantages: (1) The location of the defect is indeterminate because it is unclear to the inspector whether the test or reference image is defective; and (2) nuisance and false defects from mask manufacturing noise and tool optical variation can limit the usable sensitivity. The use of a new sequencing approach for a die-to-die inspection can resolve these issues without any additional scan time, without sacrifice in sensitivity requirement, and with a manageable increase in computation load. In this paper we explore another approach for die-to-die inspections using a new method of defect processing and sequencing. Utilizing die-to-die double arbitration during defect detection has been proven through extensive testing to generate accurate placement of the defect in the correct die to ensure efficient defect disposition at the AIMS step. The use of this method maintained the required inspection sensitivity for mask quality as verified with programmed-defectmask qualification and then further validated with production masks comparing the current inspection approach to the new method. Furthermore, this approach can significantly reduce the total number of defects that need to be reviewed by essentially eliminating the nuisance and false defects that can result from a die-to-die inspection. This "double-win" will significantly reduce the effort in classifying a die-to-die inspection result and will lead to improved cycle times.

  15. The CD control improvement by using CDSEM 2D measurement of complex OPC patterns

    NASA Astrophysics Data System (ADS)

    Chou, William; Cheng, Jeffrey; Lee, Adder; Cheng, James; Tzeng, Alex C.; Lu, Colbert; Yang, Ray; Lee, Hong Jen; Bandoh, Hideaki; Santo, Izumi; Zhang, Hao; Chen, Chien Kang

    2016-10-01

    As the process node becomes more advanced, the accuracy and precision in OPC pattern CD are required in mask manufacturing. CD SEM is an essential tool to confirm the mask quality such as CD control, CD uniformity and CD mean to target (MTT). Unfortunately, in some cases of arbitrary enclosed patterns or aggressive OPC patterns, for instance, line with tiny jogs and curvilinear SRAF, CD variation depending on region of interest (ROI) is a very serious problem in mask CD control, even it decreases the wafer yield. For overcoming this situation, the 2-dimensional (2D) method by Holon is adopted. In this paper, we summarize the comparisons of error budget between conventional (1D) and 2D data using CD SEM and the CD performance between mask and wafer by complex OPC patterns including ILT features.

  16. Method for maintaining precise suction strip porosities

    NASA Technical Reports Server (NTRS)

    Gallimore, Frank H. (Inventor)

    1989-01-01

    This invention relates to a masking method generally and, more particularly to a method of masking perforated titanium sheets having laminar control suction strips. As illustrated in the drawings, a nonaerodynamic surface of a perforated sheet has alternating suction strip areas and bonding land areas. Suction strip tapes overlie the bonding land areas during application of a masking material to an upper surface of the suction strip tapes. Prior to bonding the perforated sheet to a composite structure, the bonding land tapes are removed. The entire opposite aerodynamic surface is masked with tape before bonding. This invention provides a precise control of suction strip porosities by ensuring that no chemicals penetrate the suction strip areas during bonding.

  17. Epidermal growth factor in alkali-burned corneal epithelial wound healing.

    PubMed

    Singh, G; Foster, C S

    1987-06-15

    We conducted a double-masked study to evaluate the effect of epidermal growth factor on epithelial wound healing and recurrent erosions in alkali-burned rabbit corneas. Epithelial wounds 10 mm in diameter healed completely under the influence of topical epidermal growth factor, whereas the control corneas did not resurface in the center. On reversal of treatment, the previously nonhealing epithelial defects healed when treated with topical epidermal growth factor eyedrops. Conversely, the epidermal growth factor-treated and resurfaced corneas developed epithelial defects when treatment was discontinued. Histopathologic examination disclosed hyperplastic epithelium growing over the damaged stroma laden with polymorphonuclear leukocytes when treated with epidermal growth factor eyedrops, but it did not adhere to the underlying tissue. Hydropic changes were seen intracellularly as well as between the epithelial cells and the stroma.

  18. Rescue ventilation: resolving a "cannot mask ventilate, cannot intubate" situation during exchange of a Combitube for a definitive airway.

    PubMed

    Rich, James M; Mason, Andrew M; Tillmann, H A; Foreman, Michael

    2009-10-01

    Our anesthesia care team was called to care for a patient who was admitted to the emergency department with the esophageal-tracheal double-lumen airway device (Combitube, Tyco Healthcare, Nellcor, Pleasanton, California) in place, which needed to be exchanged for a definitive airway because the patient required an extended period of mechanical ventilation. Several techniques were attempted to exchange the esophageal-tracheal Combitube (ETC) without success. First, we attempted direct laryngoscopy with the ETC in place after deflation of the No. 1 proximal cuff and sweeping the ETC to the left. We were prepared to use bougie-assisted intubation but could not identify any airway anatomy. After removal of the ETC, we unsuccessfully attempted ventilation/intubation with a laryngeal mask airway (LMA Fastrach, LMA North America, San Diego, California). Our third attempt was insertion of another laryngeal mask airway (LMA Unique, LMA North America) with marginal ventilation, but we again experienced unsuccessful intubation using a fiberscope. The ETC was reinserted after each intubation attempt because mask ventilation was impossible. Before proceeding with cricothyrotomy, we repeated direct laryngoscopy but without the ETC in place. We identified the tip of the epiglottis, which allowed for bougie-assisted intubation. This obviated the need for emergency cricothyrotomy.

  19. Cryptosystem for Securing Image Encryption Using Structured Phase Masks in Fresnel Wavelet Transform Domain

    NASA Astrophysics Data System (ADS)

    Singh, Hukum

    2016-12-01

    A cryptosystem for securing image encryption is considered by using double random phase encoding in Fresnel wavelet transform (FWT) domain. Random phase masks (RPMs) and structured phase masks (SPMs) based on devil's vortex toroidal lens (DVTL) are used in spatial as well as in Fourier planes. The images to be encrypted are first Fresnel transformed and then single-level discrete wavelet transform (DWT) is apply to decompose LL,HL, LH and HH matrices. The resulting matrices from the DWT are multiplied by additional RPMs and the resultants are subjected to inverse DWT for the encrypted images. The scheme is more secure because of many parameters used in the construction of SPM. The original images are recovered by using the correct parameters of FWT and SPM. Phase mask SPM based on DVTL increases security that enlarges the key space for encryption and decryption. The proposed encryption scheme is a lens-less optical system and its digital implementation has been performed using MATLAB 7.6.0 (R2008a). The computed value of mean-squared-error between the retrieved and the input images shows the efficacy of scheme. The sensitivity to encryption parameters, robustness against occlusion, entropy and multiplicative Gaussian noise attacks have been analysed.

  20. Dissociable brain mechanisms underlying the conscious and unconscious control of behavior.

    PubMed

    van Gaal, Simon; Lamme, Victor A F; Fahrenfort, Johannes J; Ridderinkhof, K Richard

    2011-01-01

    Cognitive control allows humans to overrule and inhibit habitual responses to optimize performance in challenging situations. Contradicting traditional views, recent studies suggest that cognitive control processes can be initiated unconsciously. To further capture the relation between consciousness and cognitive control, we studied the dynamics of inhibitory control processes when triggered consciously versus unconsciously in a modified version of the stop task. Attempts to inhibit an imminent response were often successful after unmasked (visible) stop signals. Masked (invisible) stop signals rarely succeeded in instigating overt inhibition but did trigger slowing down of response times. Masked stop signals elicited a sequence of distinct ERP components that were also observed on unmasked stop signals. The N2 component correlated with the efficiency of inhibitory control when elicited by unmasked stop signals and with the magnitude of slowdown when elicited by masked stop signals. Thus, the N2 likely reflects the initiation of inhibitory control, irrespective of conscious awareness. The P3 component was much reduced in amplitude and duration on masked versus unmasked stop trials. These patterns of differences and similarities between conscious and unconscious cognitive control processes are discussed in a framework that differentiates between feedforward and feedback connections in yielding conscious experience.

  1. A single administration of cortisol acutely reduces preconscious attention for fear in anxious young men.

    PubMed

    Putman, Peter; Hermans, Erno J; Koppeschaar, Hans; van Schijndel, Alexandra; van Honk, Jack

    2007-08-01

    Chronically elevated HPA activity has often been associated with fear and anxiety, but there is evidence that single administrations of glucocorticoids may acutely reduce fear. Moreover, peri-traumatic cortisol elevation may protect against development of post-traumatic stress disorder. Hypervigilant processing of threat information plays a role in anxiety disorders and although relations with HPA functioning have been established, causality of these relations remains unclear. Presently, self-reported anxiety and response time patterns on a masked emotional Stroop task with fearful faces were measured in 20 healthy young men after double-blind, placebo-controlled oral administration of 40 mg cortisol. The masked fearful Stroop task measures vocal colornaming response latencies for pictures of neutral and fearful faces presented below the threshold for conscious perception. Results showed increased response times on trials for fearful compared to neutral faces after placebo, but this emotional Stroop effect was acutely abolished by cortisol administration. This effect was most pronounced in subjects with heightened anxiety levels. This is the first evidence showing that exogenous cortisol acutely reduces anxiety-driven selective attention to threat. These results extend earlier findings of acute fear reduction after glucocorticoid administration. This suggests interactions of HPA functioning and vigilant attention in the pathogenesis of anxiety disorders. Possible neuroendocrine mechanisms of action are discussed.

  2. Recipient Risk Factors for Graft Failure in the Cornea Donor Study

    PubMed Central

    Sugar, Alan; Tanner, Jean Paul; Dontchev, Mariya; Tennant, Brad; Schultze, Robert L.; Dunn, Steven P.; Lindquist, Thomas D.; Gal, Robin L.; Beck, Roy W.; Kollman, Craig; Mannis, Mark J.; Holland, Edward J.

    2009-01-01

    Purpose Identify recipient factors which may be related to risk of corneal graft failure Design Multi-center prospective, double-masked, controlled clinical trial Participants 1090 subjects undergoing corneal transplantation for a moderate risk condition (principally Fuchs’ dystrophy or pseudophakic corneal edema) Methods Donor corneas were assigned using a random approach without respect to recipient factors, and surgeons were masked to information about the donor cornea including donor age. Surgery and post-operative care were performed according to the surgeons’ usual routines and subjects were followed for five years. Baseline factors were evaluated for their association with graft failure. Main Outcome Measures Graft failure, defined as a regraft or a cloudy cornea that was sufficiently opaque to compromise vision for a minimum of three consecutive months. Results Preoperative diagnosis of pseudophakic/aphakic corneal edema increased graft failure risk approximately 4-fold compared with Fuchs’ dystrophy (27% vs. 7%). Prior glaucoma surgery with preoperative glaucoma medication use substantially increased the graft failure rate. Factors not strongly associated with graft failure included age, gender, diabetes, smoking, and graft size. Conclusion The risk of graft failure is significantly increased in eyes with pseudophakic or aphakic corneal edema compared with Fuchs’ dystrophy, independent of lens status, and in eyes with a history of glaucoma. PMID:19395036

  3. Extension of optical lithography by mask-litho integration with computational lithography

    NASA Astrophysics Data System (ADS)

    Takigawa, T.; Gronlund, K.; Wiley, J.

    2010-05-01

    Wafer lithography process windows can be enlarged by using source mask co-optimization (SMO). Recently, SMO including freeform wafer scanner illumination sources has been developed. Freeform sources are generated by a programmable illumination system using a micro-mirror array or by custom Diffractive Optical Elements (DOE). The combination of freeform sources and complex masks generated by SMO show increased wafer lithography process window and reduced MEEF. Full-chip mask optimization using source optimized by SMO can generate complex masks with small variable feature size sub-resolution assist features (SRAF). These complex masks create challenges for accurate mask pattern writing and low false-defect inspection. The accuracy of the small variable-sized mask SRAF patterns is degraded by short range mask process proximity effects. To address the accuracy needed for these complex masks, we developed a highly accurate mask process correction (MPC) capability. It is also difficult to achieve low false-defect inspections of complex masks with conventional mask defect inspection systems. A printability check system, Mask Lithography Manufacturability Check (M-LMC), is developed and integrated with 199-nm high NA inspection system, NPI. M-LMC successfully identifies printable defects from all of the masses of raw defect images collected during the inspection of a complex mask. Long range mask CD uniformity errors are compensated by scanner dose control. A mask CD uniformity error map obtained by mask metrology system is used as input data to the scanner. Using this method, wafer CD uniformity is improved. As reviewed above, mask-litho integration technology with computational lithography is becoming increasingly important.

  4. Feedforward and feedback control in apraxia of speech: effects of noise masking on vowel production.

    PubMed

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H

    2015-04-01

    This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed.

  5. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    PubMed Central

    Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Results Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. Conclusion The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed. PMID:25565143

  6. Realtime speckle sensing and suppression with project 1640 at Palomar

    NASA Astrophysics Data System (ADS)

    Vasisht, Gautam; Cady, Eric; Zhai, Chengxing; Lockhart, Thomas; Oppenheimer, Ben

    2014-08-01

    Palomar's Project 1640 (P1640) is the first stellar coronagraph to regularly use active coronagraphic wavefront control (CWFC). For this it has a hierarchy of offset wavefront sensors (WFS), the most important of which is the higher-order WFS (called CAL), which tracks quasi-static modes between 2-35 cycles-per-aperture. The wavefront is measured in the coronagraph at 0.01 Hz rates, providing slope targets to the upstream Palm 3000 adaptive optics (AO) system. The CWFC handles all non-common path distortions up to the coronagraphic focal plane mask, but does not sense second order modes between the WFSs and the science integral field unit (IFU); these modes determine the system's current limit. We have two CWFC operating modes: (1) P-mode, where we only control phases, generating double-sided darkholes by correcting to the largest controllable spatial frequencies, and (2) E-mode, where we can control amplitudes and phases, generating single-sided dark-holes in specified regions-of-interest. We describe the performance and limitations of both these modes, and discuss the improvements we are considering going forward.

  7. The technical consideration of multi-beam mask writer for production

    NASA Astrophysics Data System (ADS)

    Lee, Sang Hee; Ahn, Byung-Sup; Choi, Jin; Shin, In Kyun; Tamamushi, Shuichi; Jeon, Chan-Uk

    2016-10-01

    Multi-beam mask writer is under development to solve the throughput and patterning resolution problems in VSB mask writer. Theoretically, the writing time is appropriate for future design node and the resolution is improved with multi-beam mask writer. Many previous studies show the feasible results of resolution, CD control and registration. Although such technical results of development tool seem to be enough for mass production, there are still many unexpected problems for real mass production. In this report, the technical challenges of multi-beam mask writer are discussed in terms of production and application. The problems and issues are defined based on the performance of current development tool compared with the requirements of mask quality. Using the simulation and experiment, we analyze the specific characteristics of electron beam in multi-beam mask writer scheme. Consequently, we suggest necessary specifications for mass production with multi-beam mask writer in the future.

  8. Clinical efficacy and safety of a light mask for prevention of dark adaptation in treating and preventing progression of early diabetic macular oedema at 24 months (CLEOPATRA): a multicentre, phase 3, randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Vasconcelos, Joana C; Prevost, A Toby; Holmes, Helen; Hykin, Philip; George, Sheena; Murphy, Caroline; Kelly, Joanna; Arden, Geoffrey B

    2018-05-01

    We aimed to assess 24-month outcomes of wearing an organic light-emitting sleep mask as an intervention to treat and prevent progression of non-central diabetic macular oedema. CLEOPATRA was a phase 3, single-blind, parallel-group, randomised controlled trial undertaken at 15 ophthalmic centres in the UK. Adults with non-centre-involving diabetic macular oedema were randomly assigned (1:1) to wearing either a light mask during sleep (Noctura 400 Sleep Mask, PolyPhotonix Medical, Sedgefield, UK) or a sham (non-light) mask, for 24 months. Randomisation was by minimisation generated by a central web-based computer system. Outcome assessors were masked technicians and optometrists. The primary outcome was the change in maximum retinal thickness on optical coherence tomography (OCT) at 24 months, analysed using a linear mixed-effects model incorporating 4-monthly measurements and baseline adjustment. Analysis was done using the intention-to-treat principle in all randomised patients with OCT data. Safety was assessed in all patients. This trial is registered with Controlled-Trials.com, number ISRCTN85596558. Between April 10, 2014, and June 15, 2015, 308 patients were randomly assigned to wearing the light mask (n=155) or a sham mask (n=153). 277 patients (144 assigned the light mask and 133 the sham mask) contributed to the mixed-effects model over time, including 246 patients with OCT data at 24 months. The change in maximum retinal thickness at 24 months did not differ between treatment groups (mean change -9·2 μm [SE 2·5] for the light mask vs -12·9 μm [SE 2·9] for the sham mask; adjusted mean difference -0·65 μm, 95% CI -6·90 to 5·59; p=0·84). Median compliance with wearing the light mask at 24 months was 19·5% (IQR 1·9-51·6). No serious adverse events were related to either mask. The most frequent adverse events related to the assigned treatment were discomfort on the eyes (14 with the light mask vs seven with the sham mask), painful, sticky, or watery eyes (14 vs six), and sleep disturbance (seven vs one). The light mask as used in this study did not confer long-term therapeutic benefit on non-centre-involving diabetic macular oedema and the study does not support its use for this indication. The Efficacy and Mechanism Evaluation Programme, a Medical Research Council and National Institute for Health Research partnership. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  9. Review of economic evaluations of mask and respirator use for protection against respiratory infection transmission.

    PubMed

    Mukerji, Shohini; MacIntyre, C Raina; Newall, Anthony T

    2015-10-13

    There has been increasing debate surrounding mask and respirator interventions to control respiratory infection transmission in both healthcare and community settings. As decision makers are considering the recommendations they should evaluate how to provide the most efficient protection strategies with minimum costs. The aim of this review is to identify and evaluate the existing economic evaluation literature in this area and to offer advice on how future evaluations on this topic should be conducted. We searched the Scopus database for all literature on economic evaluation of mask or respirator use to control respiratory infection transmission. Reference lists from the identified studies were also manually searched. Seven studies met our inclusion criteria from the initial 806 studies identified by the search strategy and our manual search. Five studies considered interventions for seasonal and/or pandemic influenza, with one also considering SARS (Severe Acute Respiratory Syndrome). The other two studies focussed on tuberculosis transmission control interventions. The settings and methodologies of the studies varied greatly. No low-middle income settings were identified. Only one of the reviewed studies cited clinical evidence to inform their mask/respirator intervention effectiveness parameters. Mask and respirator interventions were generally reported by the study authors to be cost saving or cost-effective when compared to no intervention or other control measures, however the evaluations had important limitations. Given the large cost differential between masks and respirators, there is a need for more comprehensive economic evaluations to compare the relative costs and benefits of these interventions in situations and settings where alternative options are potentially applicable. There are at present insufficient well conducted cost-effectiveness studies to inform decision-makers on the value for money of alternative mask/respirator options.

  10. The verification of printability about marginal defects and the detectability at the inspection tool in sub 50nm node

    NASA Astrophysics Data System (ADS)

    Lee, Hyemi; Jeong, Goomin; Seo, Kangjun; Kim, Sangchul; kim, changreol

    2008-05-01

    Since mask design rule is smaller and smaller, Defects become one of the issues dropping the mask yield. Furthermore controlled defect size become smaller while masks are manufactured. According to ITRS roadmap on 2007, controlled defect size is 46nm in 57nm node and 36nm in 45nm node on a mask. However the machine development is delayed in contrast with the speed of the photolithography development. Generally mask manufacturing process is divided into 3 parts. First part is patterning on a mask and second part is inspecting the pattern and repairing the defect on the mask. At that time, inspection tools of transmitted light type are normally used and are the most trustful as progressive type in the developed inspection tools until now. Final part is shipping the mask after the qualifying the issue points and weak points. Issue points on a mask are qualified by using the AIMS (Aerial image measurement system). But this system is including the inherent error possibility, which is AIMS measures the issue points based on the inspection results. It means defects printed on a wafer are over the specific size detected by inspection tools and the inspection tool detects the almost defects. Even though there are no tools to detect the 46nm and 36nm defects suggested by ITRS roadmap, this assumption is applied to manufacturing the 57nm and 45nm device. So we make the programmed defect mask consisted with various defect type such as spot, clear extension, dark extension and CD variation on L/S(line and space), C/H(contact hole) and Active pattern in 55nm and 45nm node. And the programmed defect mask was inspected by using the inspection tool of transmitted light type and was measured by using AIMS 45-193i. Then the marginal defects were compared between the inspection tool and AIMS. Accordingly we could verify whether defect size is proper or not, which was suggested to be controlled on a mask by ITRS roadmap. Also this result could suggest appropriate inspection tools for next generation device among the inspection tools of transmitted light type, reflected light type and aerial image type.

  11. Robust source and mask optimization compensating for mask topography effects in computational lithography.

    PubMed

    Li, Jia; Lam, Edmund Y

    2014-04-21

    Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.

  12. ArF halftone PSM cleaning process optimization for next-generation lithography

    NASA Astrophysics Data System (ADS)

    Son, Yong-Seok; Jeong, Seong-Ho; Kim, Jeong-Bae; Kim, Hong-Seok

    2000-07-01

    ArF lithography which is expected for the next generation optical lithography is adapted for 0.13 micrometers design-rule and beyond. ArF half-tone phase shift mask (HT PSM) will be applied as 1st generation of ArF lithography. Also ArF PSM cleaning demands by means of tighter controls related to phase angle, transmittance and contamination on the masks. Phase angle on ArF HT PSM should be controlled within at least +/- 3 degree and transmittance controlled within at least +/- 3 percent after cleaning process and pelliclization. In the cleaning process of HT PSM, requires not only the remove the particle on mask, but also control to half-tone material for metamorphosis. Contamination defects on the Qz of half tone type PSM is not easy to remove on the photomask surface. New technology and methods of cleaning will be developed in near future, but we try to get out for limit contamination on the mask, without variation of phase angle and transmittance after cleaning process.

  13. FPGA chip performance improvement with gate shrink through alternating PSM 90nm process

    NASA Astrophysics Data System (ADS)

    Yu, Chun-Chi; Shieh, Ming-Feng; Liu, Erick; Lin, Benjamin; Ho, Jonathan; Wu, Xin; Panaite, Petrisor; Chacko, Manoj; Zhang, Yunqiang; Lei, Wen-Kang

    2005-11-01

    In the post-physical verification space called 'Mask Synthesis' a key component of design-for-manufacturing (DFM), double-exposure based, dark-field, alternating PSM (Alt-PSM) is being increasingly applied at the 90nm node in addition with other mature resolution enhancement techniques (RETs) such as optical proximity correction (OPC) and sub-resolution assist features (SRAF). Several high-performance IC manufacturers already use alt-PSM technology in 65nm production. At 90nm having strong control over the lithography process is a critical component in meeting targeted yield goals. However, implementing alt-PSM in production has been challenging due to several factors such as phase conflict errors, mask manufacturing, and the increased production cost due to the need for two masks in the process. Implementation of Alt-PSM generally requires phase compliance rules and proper phase topology in the layout and this has been successful for the technology node with these rules implemented. However, this may not be true for a mature, production process technology, in this case 90 nm. Especially, in the foundry-fabless business model where the foundry provides a standard set of design rules to its customers for a given process technology, and where not all the foundry customers require Alt-PSM in their tapeout flow. With minimum design changes, design houses usually are motivated by higher product performance for the existing designs. What follows is an in-depth review of the motivation to apply alt-PSM on a production FPGA, the DFM challenges to each partner faced, its effect on the tapeout flow, and how design, manufacturing, and EDA teams worked together to resolve phase conflicts, tapeout the chip, and finally verify the silicon results in production.

  14. Study of shape evaluation for mask and silicon using large field of view

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Shinoda, Shinichi; Toyoda, Yasutaka

    2010-09-01

    We have developed a highly integrated method of mask and silicon metrology. The aim of this integration is evaluating the performance of the silicon corresponding to Hotspot on a mask. It can use the mask shape of a large field, besides. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. As an optimal solution to these issues, we provide a DFM solution that extracts 2-dimensional data for a more realistic and error-free simulation by reproducing accurately the contour of the actual mask, in addition to the simulation results from the mask data. On the other hand, there is roughness in the silicon form made from a mass-production line. Moreover, there is variation in the silicon form. For this reason, quantification of silicon form is important, in order to estimate the performance of a pattern. In order to quantify, the same form is equalized in two dimensions. And the method of evaluating based on the form is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. •Discrimination of nuisance defects for fine pattern. •Determination of two-dimensional variability of pattern. •Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the form of the same location of Design, Mask, and Silicon in such a viewpoint. And we report it about algorithm of the image composition in Large Field.

  15. Ocular safety of sildenafil citrate when administered chronically for pulmonary arterial hypertension: results from phase III, randomised, double masked, placebo controlled trial and open label extension

    PubMed Central

    Tressler, Charles; Hwang, Lie-Ju; Burgess, Gary; Laties, Alan M

    2012-01-01

    Objective To assess the ocular effects and safety profile of chronic sildenafil oral dosing in patients with pulmonary arterial hypertension. Design 12 week, double masked, randomised, placebo controlled, phase III trial with open label extension. Setting 53 institutions worldwide. Participants 277 adults with idiopathic pulmonary arterial hypertension or pulmonary arterial hypertension associated with connective tissue disease or after congenital heart disease repair (mean pulmonary artery pressure ≥25 mm Hg; pulmonary capillary wedge pressure ≤15 mm Hg at rest). Interventions During the double masked study, oral sildenafil 20 mg, 40 mg, or 80 mg or placebo (1:1:1:1) three times daily for 12 weeks was added to baseline drug treatment. In the extension study, the placebo, 20 mg and 40 mg groups received 40 mg three times daily titrated to 80 mg three times daily at week 6. After unmasking, the dose was titrated according to clinical need. Main outcome measure Ocular safety (ocular examinations, visual function tests, participants’ reports of adverse events, and visual disturbance questionnaire completed by investigators) by treatment group at 12 weeks, 24 weeks, 18 months, and yearly. Results Findings of the objective assessments—that is, intraocular pressure and visual function tests (visual acuity, colour vision, and visual field)—were similar across groups (20 mg, n=69; 40 mg, n=67; 80 mg, n=71; placebo, n=70). No clinically significant changes occurred between baseline and 12 weeks, except for an efficacy signal in contrast sensitivity for the sildenafil 40 mg three times daily group. In right eyes, changes in intraocular pressure from baseline to week 12 ranged from a mean of −0.5 (95% confidence interval −1.3 to 0.2) mm Hg with placebo, −0.2 (−0.9 to 0.5) mm Hg with sildenafil 40 mg, and −0.1 (−0.7 to 0.5) mm Hg with 80 mg to 0.3 (−0.4 to 0.9) mm Hg with sildenafil 20 mg (the approved dose for pulmonary arterial hypertension). Mean changes from baseline to week 12 in contrast sensitivity in right eyes were −0.02 (SD 0.12) in the sildenafil 20 mg three times daily group compared with −0.05 (0.18) in the placebo group (P=0.044). Percentages of participants with deterioration in visual acuity (Snellen) from baseline to week 12 ranged from 10% (n=7) in the placebo group to 3% (n=2) in the sildenafil 20 mg three times daily group; the same percentages had visual field changes from normal to abnormal during the period in these two groups. The investigators did not deem any findings on colour vision assessment to be clinically significant. Findings of the objective assessments in the 40 mg and 80 mg three times daily sildenafil treatment groups and in left eyes were not substantially different, nor were any measures different throughout the open label extension compared with week 12. However, objective data were limited after month 18, as most participants had missing data or visual parameters were no longer collected by investigators. Incidence of ocular adverse events reported on the case report forms and assessed by the investigator was low with all doses, but a modest, dose related incidence of chromatopsia, cyanopsia, photophobia, and visual disturbance was reported with 80 mg three times daily consistent with the indicated dosing for erectile dysfunction. Retinal haemorrhages, captured on funduscopy, occurred in 2% (4/207) of sildenafil treated participants and none in the placebo group during the double masked study and in 4% (10/259) during the open label extension. Conclusions Sildenafil dosing up to 80 mg three times daily is safe and well tolerated from an ocular perspective in patients with pulmonary arterial hypertension. Daily chronic dosing in this patient population was not associated with visual change and had no detrimental effect on best corrected visual acuity, contrast sensitivity, colour vision, or visual field, or on slit lamp examinations, funduscopy, or intraocular pressure during the duration of this study. Trial registration Clinical trials NCT00644605 and NCT00159887. PMID:22354598

  16. Visual Masking in Schizophrenia: Overview and Theoretical Implications

    PubMed Central

    Green, Michael F.; Lee, Junghee; Wynn, Jonathan K.; Mathis, Kristopher I.

    2011-01-01

    Visual masking provides several key advantages for exploring the earliest stages of visual processing in schizophrenia: it allows for control over timing at the millisecond level, there are several well-supported theories of the underlying neurobiology of visual masking, and it is amenable to examination by electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI). In this paper, we provide an overview of the visual masking impairment schizophrenia, including the relevant theoretical mechanisms for masking impairment. We will discuss its relationship to clinical symptoms, antipsychotic medications, diagnostic specificity, and presence in at-risk populations. As part of this overview, we will cover the neural correlates of visual masking based on recent findings from EEG and fMRI. Finally, we will suggest a possible mechanism that could explain the patterns of masking findings and other visual processing findings in schizophrenia. PMID:21606322

  17. Characterising a holographic modal phase mask for the detection of ocular aberrations

    NASA Astrophysics Data System (ADS)

    Corbett, A. D.; Leyva, D. Gil; Diaz-Santana, L.; Wilkinson, T. D.; Zhong, J. J.

    2005-12-01

    The accurate measurement of the double-pass ocular wave front has been shown to have a broad range of applications from LASIK surgery to adaptively corrected retinal imaging. The ocular wave front can be accurately described by a small number of Zernike circle polynomials. The modal wave front sensor was first proposed by Neil et al. and allows the coefficients of the individual Zernike modes to be measured directly. Typically the aberrations measured with the modal sensor are smaller than those seen in the ocular wave front. In this work, we investigated a technique for adapting a modal phase mask for the sensing of the ocular wave front. This involved extending the dynamic range of the sensor by increasing the pinhole size to 2.4mm and optimising the mask bias to 0.75λ. This was found to decrease the RMS error by up to a factor of three for eye-like aberrations with amplitudes up to 0.2μm. For aberrations taken from a sample of real-eye measurements a 20% decrease in the RMS error was observed.

  18. LMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background The most important action in the resuscitation of a newborn in the delivery room is to establish effective assisted ventilation. The face mask and endotracheal tube are the devices used to achieve this goal. Laryngeal mask airways that fit over the laryngeal inlet have been shown to be effective for ventilating newborns at birth and should be considered as an alternative to facemask ventilation or endotracheal intubation among newborns weighing >2,000 g or delivered ≥34 weeks’ gestation. A recent systematic review and meta-analysis of supraglottic airways in neonatal resuscitation reported the results of four randomized controlled trials (RCTs) stating that fewer infants in the group using laryngeal mask airways required endotracheal intubation (1.5%) compared to the group using face masks (12.0%). However, there were methodological concerns over all the RCTs including the fact that the majority of the operators in the trials were anesthesiologists. Our hypothesis is based on the assumption that ventilating newborns needing positive pressure ventilation with a laryngeal mask airway will be more effective than ventilating with a face mask in a setting where neonatal resuscitation is performed by midwives, nurses, and pediatricians. The primary aim of this study will be to assess the effectiveness of the laryngeal mask airway over the face mask in preventing the need for endotracheal intubation. Methods/design This will be an open, prospective, randomized, single center, clinical trial. In this study, 142 newborns weighing >1,500 g or delivered ≥34 weeks gestation needing positive pressure ventilation at birth will be randomized to be ventilated with a laryngeal mask airway (LMA SupremeTM, LMA Company, UK - intervention group) or with a face mask (control group). Primary outcome: Proportion of newborns needing endotracheal intubation. Secondary outcomes: Apgar score at 5 minutes, time to first breath, onset of the first cry, duration of resuscitation, death or moderate to severe hypoxic-ischemic encephalopathy within 7 days of life. Trial registration ClinicalTrials.gov identifier: NCT01963936 (October 11, 2013). PMID:25027230

  19. When things go pear shaped: contour variations of contacts

    NASA Astrophysics Data System (ADS)

    Utzny, Clemens

    2013-04-01

    Traditional control of critical dimensions (CD) on photolithographic masks considers the CD average and a measure for the CD variation such as the CD range or the standard deviation. Also systematic CD deviations from the mean such as CD signatures are subject to the control. These measures are valid for mask quality verification as long as patterns across a mask exhibit only size variations and no shape variation. The issue of shape variations becomes especially important in the context of contact holes on EUV masks. For EUV masks the CD error budget is much smaller than for standard optical masks. This means that small deviations from the contact shape can impact EUV waver prints in the sense that contact shape deformations induce asymmetric bridging phenomena. In this paper we present a detailed study of contact shape variations based on regular product data. Two data sets are analyzed: 1) contacts of varying target size and 2) a regularly spaced field of contacts. Here, the methods of statistical shape analysis are used to analyze CD SEM generated contour data. We demonstrate that contacts on photolithographic masks do not only show size variations but exhibit also pronounced nontrivial shape variations. In our data sets we find pronounced shape variations which can be interpreted as asymmetrical shape squeezing and contact rounding. Thus we demonstrate the limitations of classic CD measures for describing the feature variations on masks. Furthermore we show how the methods of statistical shape analysis can be used for quantifying the contour variations thus paving the way to a new understanding of mask linearity and its specification.

  20. Effectiveness of activated carbon masks in preventing anticancer drug inhalation.

    PubMed

    Sato, Junya; Kogure, Atushi; Kudo, Kenzo

    2016-01-01

    The exposure of healthcare workers to anticancer drugs such as cyclophosphamide (CPA) is a serious health concern. Anticancer drug pollution may spread outside biological safety cabinets even when a closed system is used. The inhalation of vaporized anticancer drugs is thought to be the primary route of exposure. Therefore, it is important that healthcare workers wear masks to prevent inhalation of anticancer drugs. However, the permeability of medical masks to vaporized anticancer drugs has not been examined. Furthermore, the performance differences between masks including activated carbon with chemical adsorptivity and non-activated carbon masks are uncertain. We investigated activated carbon mask permeability to vaporized CPA, and assessed whether inhibition of vaporized CPA permeability was attributable to the masks' adsorption abilities. A CPA solution (4 mg) was vaporized in a chamber and passed through three types of masks: Pleated-type cotton mask (PCM), pleated-type activated carbon mask (PAM), and stereoscopic-type activated carbon mask (SAM); the flow rate was 1.0 L/min for 1 h. The air was then recovered in 50 % ethanol. CPA quantities in the solution were determined by liquid chromatography time-of-flight mass spectrometry. To determine CPA adsorption by the mask, 5 cm 2 of each mask was immersed in 10 mL of CPA solution (50-2500 μg/mL) for 1 h. CPA concentrations were measured by high-performance liquid chromatography with ultraviolet detection. For the control (no mask), 3.735 ± 0.543 μg of CPA was recovered from the aerated solution. Significantly lower quantities were recovered from PCM (0.538 ± 0.098 μg) and PAM (0.236 ± 0.193 μg) ( p  < 0.001 and p  < 0.001 vs control, respectively). CPA quantities recovered from all of SAM samples were below the quantification limit. When a piece of the SAM was immersed in the CPA solution, a marked decrease to less than 3.1 % of the initial CPA concentration was observed. The SAM exhibited good adsorption ability, and this characteristic may contribute to avoiding inhalation exposure to vaporized CPA. These results suggest that wearing activated carbon masks may prevent anticancer drug inhalation by healthcare workers.

  1. Nasal mask ventilation is better than face mask ventilation in edentulous patients.

    PubMed

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.

  2. Improved mask-based CD uniformity for gridded-design-rule lithography

    NASA Astrophysics Data System (ADS)

    Faivishevsky, Lev; Khristo, Sergey; Sagiv, Amir; Mangan, Shmoolik

    2009-03-01

    The difficulties encountered during lithography of state-of-the-art 2D patterns are formidable, and originate from the fact that deep sub-wavelength features are being printed. This results in a practical limit of k1 >=0.4 as well as a multitude of complex restrictive design rules, in order to mitigate or minimize lithographic hot spots. An alternative approach, that is gradually attracting the lithographic community's attention, restricts the design of critical layers to straight, dense lines (a 1D grid), that can be relatively easily printed using current lithographic technology. This is then followed by subsequent, less critical trimming stages to obtain circuit functionality. Thus, the 1D gridded approach allows hotspot-free, proximity-effect free lithography of ultra low- k1 features. These advantages must be supported by a stable CD control mechanism. One of the overriding parameters impacting CDU performance is photo mask quality. Previous publications have demonstrated that IntenCDTM - a novel, mask-based CDU mapping technology running on Applied Materials' Aera2TM aerial imaging mask inspection tool - is ideally fit for detecting mask-based CDU issues in 1D (L&S) patterned masks for memory production. Owing to the aerial nature of image formation, IntenCD directly probes the CD as it is printed on the wafer. In this paper we suggest that IntenCD is naturally fit for detecting mask-based CDU issues in 1D GDR masks. We then study a novel method of recovering and quantifying the physical source of printed CDU, using a novel implementation of the IntenCD technology. We demonstrate that additional, simple measurements, which can be readily performed on board the Aera2TM platform with minimal throughput penalty, may complement IntenCD and allow a robust estimation of the specific nature and strength of mask error source, such as pattern width variation or phase variation, which leads to CDU issues on the printed wafer. We finally discuss the roles played by IntenCD in advanced GDR mask production, starting with tight control over mask production process, continuing to mask qualification at mask shop and ending at in-line wafer CDU correction in fabs.

  3. Propagation of resist heating mask error to wafer level

    NASA Astrophysics Data System (ADS)

    Babin, S. V.; Karklin, Linard

    2006-10-01

    As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the mask error budget - the resist heating CD error. In simulation of exposure using a stepper, variable MEEF was considered.

  4. Automatic pattern localization across layout database and photolithography mask

    NASA Astrophysics Data System (ADS)

    Morey, Philippe; Brault, Frederic; Beisser, Eric; Ache, Oliver; Röth, Klaus-Dieter

    2016-03-01

    Advanced process photolithography masks require more and more controls for registration versus design and critical dimension uniformity (CDU). The distribution of the measurement points should be distributed all over the whole mask and may be denser in areas critical to wafer overlay requirements. This means that some, if not many, of theses controls should be made inside the customer die and may use non-dedicated patterns. It is then mandatory to access the original layout database to select patterns for the metrology process. Finding hundreds of relevant patterns in a database containing billions of polygons may be possible, but in addition, it is mandatory to create the complete metrology job fast and reliable. Combining, on one hand, a software expertise in mask databases processing and, on the other hand, advanced skills in control and registration equipment, we have developed a Mask Dataprep Station able to select an appropriate number of measurement targets and their positions in a huge database and automatically create measurement jobs on the corresponding area on the mask for the registration metrology system. In addition, the required design clips are generated from the database in order to perform the rendering procedure on the metrology system. This new methodology has been validated on real production line for the most advanced process. This paper presents the main challenges that we have faced, as well as some results on the global performances.

  5. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

    PubMed

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S

    2016-09-15

    Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  6. Software-based data path for raster-scanned multi-beam mask lithography

    NASA Astrophysics Data System (ADS)

    Rajagopalan, Archana; Agarwal, Ankita; Buck, Peter; Geller, Paul; Hamaker, H. Christopher; Rao, Nagswara

    2016-10-01

    According to the 2013 SEMATECH Mask Industry Survey,i roughly half of all photomasks are produced using laser mask pattern generator ("LMPG") lithography. LMPG lithography can be used for all layers at mature technology nodes, and for many non-critical and semi-critical masks at advanced nodes. The extensive use of multi-patterning at the 14-nm node significantly increases the number of critical mask layers, and the transition in wafer lithography from positive tone resist to negative tone resist at the 14-nm design node enables the switch from advanced binary masks back to attenuated phase shifting masks that require second level writes to remove unwanted chrome. LMPG lithography is typically used for second level writes due to its high productivity, absence of charging effects, and versatile non-actinic alignment capability. As multi-patterning use expands from double to triple patterning and beyond, the number of LMPG second level writes increases correspondingly. The desire to reserve the limited capacity of advanced electron beam writers for use when essential is another factor driving the demand for LMPG capacity. The increasing demand for cost-effective productivity has kept most of the laser mask writers ever manufactured running in production, sometimes long past their projected lifespan, and new writers continue to be built based on hardware developed some years ago.ii The data path is a case in point. While state-ofthe- art when first introduced, hardware-based data path systems are difficult to modify or add new features to meet the changing requirements of the market. As data volumes increase, design styles change, and new uses are found for laser writers, it is useful to consider a replacement for this critical subsystem. The availability of low-cost, high-performance, distributed computer systems combined with highly scalable EDA software lends itself well to creating an advanced data path system. EDA software, in routine production today, scales well to hundreds or even thousands of CPU-cores, offering the potential for virtually unlimited capacity. Features available in EDA software such as sizing, scaling, tone reversal, OPC, MPC, rasterization, and others are easily adapted to the requirements of a data path system. This paper presents the motivation, requirements, design and performance of an advanced, scalable software data path system suitable to support multi-beam laser mask lithography.

  7. A pilot study on the use of geometrically accurate face models to replicate ex vivo N95 mask fit.

    PubMed

    Golshahi, Laleh; Telidetzki, Karla; King, Ben; Shaw, Diana; Finlay, Warren H

    2013-01-01

    To test the feasibility of replicating a face mask seal in vitro, we created 5 geometrically accurate reconstructions of the head and neck of an adult human subject using different materials. Three breathing patterns were simulated with each replica and an attached N95 mask. Quantitative fit testing on the subject and the replicas showed that none of the 5 isotropic materials used allowed duplication of the ex vivo mask seal for the specific mask-face combination studied. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. The flash memory battle: How low can we go?

    NASA Astrophysics Data System (ADS)

    van Setten, Eelco; Wismans, Onno; Grim, Kees; Finders, Jo; Dusa, Mircea; Birkner, Robert; Richter, Rigo; Scherübl, Thomas

    2008-03-01

    With the introduction of the TWINSCAN XT:1900Gi the limit of the water based hyper-NA immersion lithography has been reached in terms of resolution. With a numerical aperture of 1.35 a single expose resolution of 36.5nm half pitch has been demonstrated. However the practical resolution limit in production will be closer to 40nm half pitch, without having to go to double patterning alike strategies. In the relentless Flash memory market the performance of the exposure tool is stretched to the limit for a competitive advantage and cost-effective product. In this paper we will present the results of an experimental study of the resolution limit of the NAND-Flash Memory Gate layer for a production-worthy process on the TWINSCAN XT:1900Gi. The entire gate layer will be qualified in terms of full wafer CD uniformity, aberration sensitivities for the different wordlines and feature-center placement errors for 38, 39, 40 and 43nm half pitch design rule. In this study we will also compare the performance of a binary intensity mask to a 6% attenuated phase shift mask and look at strategies to maximize Depth of Focus, and to desensitize the gate layer for lens aberrations and placement errors. The mask is one of the dominant contributors to the CD uniformity budget of the flash gate layer. Therefore the wafer measurements are compared to aerial image measurements of the mask using AIMSTM 45-193i to separate the mask contribution from the scanner contribution to the final imaging performance.

  9. Phase-retrieval attack free cryptosystem based on cylindrical asymmetric diffraction and double-random phase encoding

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Li, Xiaowei; Hu, Yuhen; Wang, Qiong-Hua

    2018-03-01

    A phase-retrieval attack free cryptosystem based on the cylindrical asymmetric diffraction and double-random phase encoding (DRPE) is proposed. The plaintext is abstract as a cylinder, while the observed diffraction and holographic surfaces are concentric cylinders. Therefore, the plaintext can be encrypted through a two-step asymmetric diffraction process with double pseudo random phase masks located on the object surface and the first diffraction surface. After inverse diffraction from a holographic surface to an object surface, the plaintext can be reconstructed using a decryption process. Since the diffraction propagated from the inner cylinder to the outer cylinder is different from that of the reversed direction, the proposed cryptosystem is asymmetric and hence is free of phase-retrieval attack. Numerical simulation results demonstrate the flexibility and effectiveness of the proposed cryptosystem.

  10. Photodetectors on Coronagraph Mask for Pointing Control

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatham

    2007-01-01

    It has been proposed to install a symmetrical array of photodetectors about the center of the mask of a coronagraph of the type used to search for planets orbiting remote stars. The purpose of this installation is to utilize the light from a star under observation as a guide in pointing the telescope. Simple arithmetic processing of the outputs of the photodetectors would provide indications of the lateral position of the center of the mask relative to the center of the image of the star. These indications could serve as pointing-control feedback signals for adjusting the telescope aim to center the image of the star on the mask. The widths of central mask areas available for placement of photodetectors differ among coronagraph designs, typically ranging upward from about 100 m. Arrays of photodetectors can readily be placed within areas in this size range. The number of detectors in an array could be as small as 4 or as large as 64. The upper limit on the number of detectors would be determined according to the extent of the occulting pattern and the number of functionalities, in addition to pointing control, to be served by the array.

  11. Abnormal auditory forward masking pattern in the brainstem response of individuals with Asperger syndrome

    PubMed Central

    Källstrand, Johan; Olsson, Olle; Nehlstedt, Sara Fristedt; Sköld, Mia Ling; Nielzén, Sören

    2010-01-01

    Abnormal auditory information processing has been reported in individuals with autism spectrum disorders (ASD). In the present study auditory processing was investigated by recording auditory brainstem responses (ABRs) elicited by forward masking in adults diagnosed with Asperger syndrome (AS). Sixteen AS subjects were included in the forward masking experiment and compared to three control groups consisting of healthy individuals (n = 16), schizophrenic patients (n = 16) and attention deficit hyperactivity disorder patients (n = 16), respectively, of matching age and gender. The results showed that the AS subjects exhibited abnormally low activity in the early part of their ABRs that distinctly separated them from the three control groups. Specifically, wave III amplitudes were significantly lower in the AS group than for all the control groups in the forward masking condition (P < 0.005), which was not the case in the baseline condition. Thus, electrophysiological measurements of ABRs to complex sound stimuli (eg, forward masking) may lead to a better understanding of the underlying neurophysiology of AS. Future studies may further point to specific ABR characteristics in AS individuals that separate them from individuals diagnosed with other neurodevelopmental diseases. PMID:20628629

  12. Different effects of the two types of spatial pre-cueing: what precisely is "attention" in Di Lollo's and Enns' substitution masking theory?

    PubMed

    Luiga, I; Bachmann, T

    2007-11-01

    Enns and Di Lollo [Psychological Science, 8 (2), 135-139, 1997] have introduced the object substitution theory of visual masking. Object substitution masking occurs when focusing attention on the target is delayed. However, Posner (Quarterly Journal of Experimental Psychology, 32, 3-25, 1980) has already shown that attention can be directed to a target at least in two ways: intentionally (endogenously) and automatically (exogenously). We conducted two experiments to explore the effects of endogenous and exogenous cues on substitution masking. The results showed that when attention was shifted to the target location automatically (using a local peripheral pre-cue), masking was attenuated. A decrease in target identification dependent on a delay of mask offset, typical to substitution masking, was not observed. However, strong substitution masking occurred when the target location was not pre-cued or when attention was directed to the target location intentionally (using a symbolic pre-cue displayed centrally). The hypothesis of two different mechanisms of attentional control in substitution masking was confirmed.

  13. The automatic back-check mechanism of mask tooling database and automatic transmission of mask tooling data

    NASA Astrophysics Data System (ADS)

    Xu, Zhe; Peng, M. G.; Tu, Lin Hsin; Lee, Cedric; Lin, J. K.; Jan, Jian Feng; Yin, Alb; Wang, Pei

    2006-10-01

    Nowadays, most foundries have paid more and more attention in order to reduce the CD width. Although the lithography technologies have developed drastically, mask data accuracy is still a big challenge than before. Besides, mask (reticle) price also goes up drastically such that data accuracy needs more special treatments.We've developed a system called eFDMS to guarantee the mask data accuracy. EFDMS is developed to do the automatic back-check of mask tooling database and the data transmission of mask tooling. We integrate our own EFDMS systems to engage with the standard mask tooling system K2 so that the upriver and the downriver processes of the mask tooling main body K2 can perform smoothly and correctly with anticipation. The competition in IC marketplace is changing from high-tech process to lower-price gradually. How to control the reduction of the products' cost more plays a significant role in foundries. Before the violent competition's drawing nearer, we should prepare the cost task ahead of time.

  14. A mask quality control tool for the OSIRIS multi-object spectrograph

    NASA Astrophysics Data System (ADS)

    López-Ruiz, J. C.; Vaz Cedillo, Jacinto Javier; Ederoclite, Alessandro; Bongiovanni, Ángel; González Escalera, Víctor

    2012-09-01

    OSIRIS multi object spectrograph uses a set of user-customised-masks, which are manufactured on-demand. The manufacturing process consists of drilling the specified slits on the mask with the required accuracy. Ensuring that slits are on the right place when observing is of vital importance. We present a tool for checking the quality of the process of manufacturing the masks which is based on analyzing the instrument images obtained with the manufactured masks on place. The tool extracts the slit information from these images, relates specifications with the extracted slit information, and finally communicates to the operator if the manufactured mask fulfills the expectations of the mask designer. The proposed tool has been built using scripting languages and using standard libraries such as opencv, pyraf and scipy. The software architecture, advantages and limits of this tool in the lifecycle of a multiobject acquisition are presented.

  15. Emotional conditioning to masked stimuli and modulation of visuospatial attention.

    PubMed

    Beaver, John D; Mogg, Karin; Bradley, Brendan P

    2005-03-01

    Two studies investigated the effects of conditioning to masked stimuli on visuospatial attention. During the conditioning phase, masked snakes and spiders were paired with a burst of white noise, or paired with an innocuous tone, in the conditioned stimulus (CS)+ and CS- conditions, respectively. Attentional allocation to the CSs was then assessed with a visual probe task, in which the CSs were presented unmasked (Experiment 1) or both unmasked and masked (Experiment 2), together with fear-irrelevant control stimuli (flowers and mushrooms). In Experiment 1, participants preferentially allocated attention to CS+ relative to control stimuli. Experiment 2 suggested that this attentional bias depended on the perceived aversiveness of the unconditioned stimulus and did not require conscious recognition of the CSs during both acquisition and expression. Copyright 2005 APA, all rights reserved.

  16. Randomized double-blind placebo-controlled trial of buccal misoprostol to reduce the need for additional uterotonic drugs during cesarean delivery.

    PubMed

    Hernández-Castro, Flavio; López-Serna, Norberto; Treviño-Salinas, Emilio M; Soria-López, Juan A; Sordia-Hernández, Luis H; Cárdenas-Estrada, Eloy

    2016-02-01

    To determine whether buccal misoprostol during cesarean delivery in conjunction with active management of the third stage of labor reduces the need for additional uterotonic drugs. A double-blind, randomized, placebo-controlled trial was performed in Monterrey, Mexico, between February 2008 and December 2013. Eligible women had risk factors for uterine atony and were to undergo cesarean delivery under epidural block. Using a computer-generated sequence and blocks of six, patients were randomly assigned to receive 400μg misoprostol or 800μg placebo buccally after cord clamping. Both groups received an intravenous oxytocin infusion. The primary outcome was the need for additional uterotonic drugs. Analyses were performed per protocol. Patients, investigators, and data analysts were masked to group assignment. A total of 120 women were included in analyses (60 in each group). At least one additional uterotonic drug was required in 24 (40%) women in the placebo group versus 6 (10%) women in the misoprostol group (relative risk 0.16; 95% confidence interval 0.06-0.44). No adverse effects due to misoprostol were recorded. Buccal misoprostol during cesarean delivery reduced the need for additional uterotonic drugs to treat uterine atony. ClinicalTrials.gov:NCT01733329. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  17. The effects of alcohol mixed with energy drink (AMED) on subjective intoxication and alertness: results from a double-blind placebo-controlled clinical trial.

    PubMed

    van de Loo, Aurora J A E; van Andel, Nienke; van Gelder, Charlotte A G H; Janssen, Boris S G; Titulaer, Joep; Jansen, Jimmy; Verster, Joris C

    2016-05-01

    The purpose of this double blind placebo controlled study was to examine if specific effects on subjective intoxication and alertness-sleepiness ratings could be demonstrated after consuming alcohol mixed with energy drink (AMED) when compared to consuming alcohol only (AO). 56 healthy volunteers rated their subjective intoxication on a scale ranging from 0 (sober) to 10 (highly intoxicated) at baseline, breath alcohol concentration (BAC) of 0%, and at BAC 0.08%, 0.05%, and 0.02%. Alertness-sleepiness was assessed with the Karolinska sleepiness scale. Scores of the AMED and AO condition, at each BAC level, were compared. Subjective intoxication for AMED and AO did not differ significantly from each other at any BAC level, except for BAC 0.02%. A significant increase in sleepiness scores was found in the AO condition, whereas scores remained stable in the AMED condition. Sleepiness scores at BAC0.08% and 0.05% were significantly lower after AMED when compared to AO. However, the observed differences between AMED and AO were small and have no clinical relevance. Mixing alcohol with energy drink had no overall masking effect on subjective intoxication caused by alcohol, nor had a relevant effect on subjective alertness-sleepiness ratings. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Exploring the Effect of Lactium™ and Zizyphus Complex on Sleep Quality: A Double-Blind, Randomized Placebo-Controlled Trial

    PubMed Central

    Scholey, Andrew; Benson, Sarah; Gibbs, Amy; Perry, Naomi; Sarris, Jerome; Murray, Greg

    2017-01-01

    Acute, non-clinical insomnia is not uncommon. Sufferers commonly turn to short-term use of herbal supplements to alleviate the symptoms. This placebo-controlled, double-blind study investigated the efficacy of LZComplex3 (lactium™, Zizyphus, Humulus lupulus, magnesium and vitamin B6), in otherwise healthy adults with mild insomnia. After a 7-day single-blind placebo run-in, eligible volunteers (n = 171) were randomized (1:1) to receive daily treatment for 2 weeks with LZComplex3 or placebo. Results revealed that sleep quality measured by change in Pittsburgh Sleep Quality Index (PSQI) score improved in both the LZComplex3 and placebo groups. There were no significant between group differences between baseline and endpoint on the primary outcome. The majority of secondary outcomes, which included daytime functioning and physical fatigue, mood and anxiety, cognitive performance, and stress reactivity, showed similar improvements in the LZComplex3 and placebo groups. A similar proportion of participants reported adverse events (AEs) in both groups, with two of four treatment-related AEs in the LZComplex3 group resulting in permanent discontinuation. It currently cannot be concluded that administration of LZComplex3 for 2 weeks improves sleep quality, however, a marked placebo response (despite placebo run-in) and/or short duration of treatment may have masked a potential beneficial effect on sleep quality. PMID:28218661

  19. Analysis of the ability of catcher's masks to attenuate head accelerations on impact with a baseball.

    PubMed

    Shain, Kellen S; Madigan, Michael L; Rowson, Steven; Bisplinghoff, Jill; Duma, Stefan M

    2010-11-01

    The goals of this study were to measure the ability of catcher's masks to attenuate head accelerations on impact with a baseball and to compare these head accelerations to established injury thresholds for mild traumatic brain injury. Testing involved using a pneumatic cannon to shoot baseballs at an instrumented Hybrid III headform (a 50th percentile male head and neck) with and without a catcher's mask on the head. The ball speed was controlled from approximately 26.8 to 35.8 m/s (60-80 mph), and the regulation National Collegiate Athletic Association baseballs were used. Research laboratory. None. Catcher's masks and impact velocity. The linear and angular head accelerations of the Hybrid III headform. Peak linear resultant acceleration was 140 to 180 g without a mask and 16 to 30 g with a mask over the range of ball's speed investigated. Peak angular resultant acceleration was 19 500 to 25 700 rad/s without a mask and 2250 to 3230 rad/s with a mask. The Head Injury Criterion was 93 to 181 without a mask and 3 to 13 with a mask, and the Severity Index was 110 to 210 without a mask and 3 to 15 with a mask. Catcher's masks reduced head acceleration metrics by approximately 85%. Head acceleration metrics with a catcher's mask were significantly lower than contemporary injury thresholds, yet reports in the mass media clearly indicate that baseball impacts to the mask still occasionally result in mild traumatic brain injuries. Further research is needed to address this apparent contradiction.

  20. Ocular changes with oral and transepidermal diethylcarbamazine therapy of onchocerciasis.

    PubMed Central

    Taylor, H R; Greene, B M

    1981-01-01

    Twenty men with moderate infection of Onchocerca volvulus were studied in a double-masked, controlled clinical trial to compare the safety and efficacy of oral diethylcarbamazine (DEC) with topical DEC lotion. Visual acuity and colour vision did not alter during the 6 months of observation, although 2 patients receiving DEC lotion and 3 patients receiving oral DEC developed either visual field constriction or optic atrophy. Fluffy corneal opacities were common in both groups. Intraocular microfilariae also appeared in both groups but to a greater extent in those receiving DEC lotion. New chorioretinal changes developed in 4 men receiving lotion and in only 1 receiving tablets. It is concluded that DEC lotion offers no advantage over tablets in the treatment of ocular onchocerciasis and in fact may be associated with more ocular complications than the conventional oral treatment. Images PMID:7020746

  1. Intact figure-ground segmentation in schizophrenia.

    PubMed

    Herzog, Michael H; Kopmann, Sabine; Brand, Andreas

    2004-11-30

    As revealed by backward masking studies, schizophrenic patients show strong impairments of early visual processing. However, the underlying temporal mechanisms are not yet well understood. To shed light on the exact timing of these deficits, we employed a paradigm in which two masks follow each other. We investigated 16 medicated schizophrenic patients and a matched group of 14 controls with a new backward masking technique, shine-through. In accordance with other masking studies, schizophrenic patients require a dramatically longer processing time to reach a predefined performance level compared with healthy subjects. However, patients are surprisingly sensitive to subtle differences in the timing of the two masks, revealing good temporal resolution. This good temporal resolution indicates intact and fast perceptual grouping and figure-ground segmentation in spite of high susceptibility to masking procedures in schizophrenia.

  2. Randomized Double Masked Trial of Zhi Byed 11, a Tibetan Traditional Medicine, Versus Misoprostol to Prevent Postpartum Hemorrhage in Lhasa, Tibet

    PubMed Central

    Miller, Suellen; Tudor, Carrie; Thorsten, Vanessa; Nyima; Kalyang; Sonam; Lhakpen; Droyoung; Quzong, Karma; Dekyi, Tsering; Hartwell, Ty; Wright, Linda L.; Varner, Michael W.

    2009-01-01

    The objective of this study was to compare a Tibetan traditional medicine (the uterotonic Zhi Byed 11 [ZB11]) to oral misoprostol for prophylaxis of postpartum hemorrhage (PPH). We conducted a double-blind randomized controlled trial at three hospitals in Lhasa, Tibet, People’s Republic of China. Women (N = 967) were randomized to either ZB11 or misoprostol groups. Postpartum blood loss was measured in a calibrated blood collection drape. The primary combined outcome was incidence of PPH, defined as measured blood loss (MBL) ≥ 500 mL, administration of open label uterotonics, or maternal death. We found that the rate of the combined outcome was lower among the misoprostol group (16.1% versus 21.8% for ZB11; P = .02). Frequency of PPH was lower with misoprostol (12.4% versus 17.4%; P = .02). There were no significant differences in MBL > 1000 mL or mean or median MBL. Fever was significantly more common in the misoprostol group (P = .03). The rate of combined outcome was significantly lower among women receiving misoprostol. However, other indices of obstetric hemorrhage were not significantly different. PMID:19249659

  3. Scotopic sensitivity/Irlen syndrome and the use of coloured filters: a long-term placebo-controlled study of reading strategies using analysis of miscue.

    PubMed

    Robinson, G L; Foreman, P J

    1999-02-01

    This study investigated the long-term effects of using coloured filters on the frequency and type of errors in oral reading. A double-masked, placebo-controlled crossover experimental design was used, with subjects being assessed over a period of 20 months. There were three experimental groups (Placebo tints, Blue tints, and Diagnosed tints) involving 113 subjects with reading difficulties, ranging in age from 9.2 yr. to 13.1 yr. The 35 controls (ranging in age from 9.4 yr. to 12.9 yr.) had reading difficulties but did not require coloured filters. There was a significant improvement for all groups in the accuracy of miscues over the period, although experimental groups over-all did not improve at a significantly different rate than the control group. The failure to find significantly greater improvement for the experimental groups over the control group for the total period, despite subjects' reports of improved print clarity, may be partly related to the lack of effective letter-sound analysis and synthesis skills and to the use of a word-identification strategy of guessing based on partial visual analysis.

  4. Efficacy of etanercept in preventing relapse of uveitis controlled by methotrexate.

    PubMed

    Foster, C Stephen; Tufail, Fehma; Waheed, Nadia Khalida; Chu, David; Miserocchi, Elisabetta; Baltatzis, Stefanos; Vredeveld, Cindy M

    2003-04-01

    To evaluate the efficacy of etanercept vs placebo in preventing relapses of uveitis in patients taking methotrexate with control of uveitis and whose methotrexate dosage was being tapered. Patients with chronic or recurrent noninfectious uveitis with inflammation controlled by low-dose methotrexate were randomized to either the drug or placebo group in a double-masked manner, given a methotrexate taper schedule, and followed for 24 weeks. The main outcome measures were control of inflammation, visual acuity, and adverse reactions. Data were analyzed both as an attempt-to-treat analysis and an analysis only of those patients who completed the study. A total of 20 patients were randomized to the drug and placebo groups. Relapse of uveitis occurred in 3 of 10 patients in the treatment group and 5 of 10 patients in the control group. Two patients in the treatment group withdrew prematurely from the study due to adverse effects. There was no significant difference between the treatment and placebo groups with regard to the rate of relapse and the final visual acuity. No patient suffered from any irreversible, long-term morbidity or mortality. Etanercept has no significant efficacy over placebo in preventing relapses of uveitis in patients being tapered from methotrexate.

  5. Experimental verification of PSM polarimetry: monitoring polarization at 193nm high-NA with phase shift masks

    NASA Astrophysics Data System (ADS)

    McIntyre, Gregory; Neureuther, Andrew; Slonaker, Steve; Vellanki, Venu; Reynolds, Patrick

    2006-03-01

    The initial experimental verification of a polarization monitoring technique is presented. A series of phase shifting mask patterns produce polarization dependent signals in photoresist and are capable of monitoring the Stokes parameters of any arbitrary illumination scheme. Experiments on two test reticles have been conducted. The first reticle consisted of a series of radial phase gratings (RPG) and employed special apertures to select particular illumination angles. Measurement sensitivities of about 0.3 percent of the clear field per percent change in polarization state were observed. The second test reticle employed the more sensitive proximity effect polarization analyzers (PEPA), a more robust experimental setup, and a backside pinhole layer for illumination angle selection and to enable characterization of the full illuminator. Despite an initial complication with the backside pinhole alignment, the results correlate with theory. Theory suggests that, once the pinhole alignment is corrected in the near future, the second reticle should achieve a measurement sensitivity of about 1 percent of the clear field per percent change in polarization state. This corresponds to a measurement of the Stokes parameters after test mask calibration, to within about 0.02 to 0.03. Various potential improvements to the design, fabrication of the mask, and experimental setup are discussed. Additionally, to decrease measurement time, a design modification and double exposure technique is proposed to enable electrical detection of the measurement signal.

  6. Reduced OSM for Long Duration Targets: Individuation or Items Loaded into VSTM?

    ERIC Educational Resources Information Center

    Guest, Duncan; Gellatly, Angus; Pilling, Michael

    2012-01-01

    Typical studies of object substitution masking (OSM) employ a briefly presented search array. The target item is indicated by a cue/mask that surrounds but does not overlap the target and, compared to a common offset control condition, report of the target is reduced when the mask remains present after target offset. Given how little observers are…

  7. Photorefractive keratectomy at 193 nm using an erodible mask

    NASA Astrophysics Data System (ADS)

    Gordon, Michael; Brint, Stephen F.; Durrie, Daniel S.; Seiler, Theo; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.

    1992-08-01

    Clinical experience with more than ten thousand sighted eyes has demonstrated great promise for correcting myopia with photorefractive keratectomy (PRK). Previously reported techniques have incorporated computer-controlled irises, diaphragms, and apertures to regulate the desired distribution of 193 nm radiation onto the eye. This paper reports on an entirely new approach for performing PRK which utilizes an erodible mask to control the shape transfer process. Compared to the more traditional techniques, the erodible mask offers promise of correcting a broad range of refractive errors. In this paper the erodible mask and associated hardware are described in detail. We describe the shape transfer experiments used to predict the functional relationship between the desired refractive correction and the mask shape. We report on early clinical results from five patients with myopic astigmatism. We conclude that the early shape transfer experiments overestimated the spherical component of the correction by 1.25 diopters and underestimated the cylindrical component by approximately 0.85 diopters. The data suggest there may be biological effects which evoke different healing responses when myopic PRK corrections are performed with and without astigmatism. Clinical trials are proceeding with the mask shapes adjusted for these observations.

  8. Nasal mask ventilation is better than face mask ventilation in edentulous patients

    PubMed Central

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. Results: A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Conclusion: Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients. PMID:27625477

  9. 64nm pitch metal1 double patterning metrology: CD and OVL control by SEMCD, image based overlay and diffraction based overlay

    NASA Astrophysics Data System (ADS)

    Ducoté, Julien; Dettoni, Florent; Bouyssou, Régis; Le-Gratiet, Bertrand; Carau, Damien; Dezauzier, Christophe

    2015-03-01

    Patterning process control of advanced nodes has required major changes over the last few years. Process control needs of critical patterning levels since 28nm technology node is extremely aggressive showing that metrology accuracy/sensitivity must be finely tuned. The introduction of pitch splitting (Litho-Etch-Litho-Etch) at 14FDSOInm node requires the development of specific metrologies to adopt advanced process control (for CD, overlay and focus corrections). The pitch splitting process leads to final line CD uniformities that are a combination of the CD uniformities of the two exposures, while the space CD uniformities are depending on both CD and OVL variability. In this paper, investigations of CD and OVL process control of 64nm minimum pitch at Metal1 level of 14FDSOI technology, within the double patterning process flow (Litho, hard mask etch, line etch) are presented. Various measurements with SEMCD tools (Hitachi), and overlay tools (KT for Image Based Overlay - IBO, and ASML for Diffraction Based Overlay - DBO) are compared. Metrology targets are embedded within a block instanced several times within the field to perform intra-field process variations characterizations. Specific SEMCD targets were designed for independent measurement of both line CD (A and B) and space CD (A to B and B to A) for each exposure within a single measurement during the DP flow. Based on those measurements correlation between overlay determined with SEMCD and with standard overlay tools can be evaluated. Such correlation at different steps through the DP flow is investigated regarding the metrology type. Process correction models are evaluated with respect to the measurement type and the intra-field sampling.

  10. Integration of mask and silicon metrology in DFM

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Sugiyama, Akiyuki; Toyoda, Yasutaka

    2009-03-01

    We have developed a highly integrated method of mask and silicon metrology. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. We have inspected the high accuracy, stability and reproducibility in the experiments of integration. The accuracy is comparable with that of the mask and silicon CD-SEM metrology. In this report, we introduce the experimental results and the application. As shrinkage of design rule for semiconductor device advances, OPC (Optical Proximity Correction) goes aggressively dense in RET (Resolution Enhancement Technology). However, from the view point of DFM (Design for Manufacturability), the cost of data process for advanced MDP (Mask Data Preparation) and mask producing is a problem. Such trade-off between RET and mask producing is a big issue in semiconductor market especially in mask business. Seeing silicon device production process, information sharing is not completely organized between design section and production section. Design data created with OPC and MDP should be linked to process control on production. But design data and process control data are optimized independently. Thus, we provided a solution of DFM: advanced integration of mask metrology and silicon metrology. The system we propose here is composed of followings. 1) Design based recipe creation: Specify patterns on the design data for metrology. This step is fully automated since they are interfaced with hot spot coordinate information detected by various verification methods. 2) Design based image acquisition: Acquire the images of mask and silicon automatically by a recipe based on the pattern design of CD-SEM.It is a robust automated step because a wide range of design data is used for the image acquisition. 3) Contour profiling and GDS data generation: An image profiling process is applied to the acquired image based on the profiling method of the field proven CD metrology algorithm. The detected edges are then converted to GDSII format, which is a standard format for a design data, and utilized for various DFM systems such as simulation. Namely, by integrating pattern shapes of mask and silicon formed during a manufacturing process into GDSII format, it makes it possible to bridge highly accurate pattern profile information over to the design field of various EDA systems. These are fully integrated into design data and automated. Bi-directional cross probing between mask data and process control data is allowed by linking them. This method is a solution for total optimization that covers Design, MDP, mask production and silicon device producing. This method therefore is regarded as a strategic DFM approach in the semiconductor metrology.

  11. Scatterometry on pelliclized masks: an option for wafer fabs

    NASA Astrophysics Data System (ADS)

    Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad

    2007-03-01

    Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.

  12. Laser Doppler imaging of cutaneous blood flow through transparent face masks: a necessary preamble to computer-controlled rapid prototyping fabrication with submillimeter precision.

    PubMed

    Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H

    2008-01-01

    A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P < .5). High valid pixel rate laser Doppler imager flow data can be obtained through transparent face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.

  13. Photomask etch system and process for 10nm technology node and beyond

    NASA Astrophysics Data System (ADS)

    Chandrachood, Madhavi; Grimbergen, Michael; Yu, Keven; Leung, Toi; Tran, Jeffrey; Chen, Jeff; Bivens, Darin; Yalamanchili, Rao; Wistrom, Richard; Faure, Tom; Bartlau, Peter; Crawford, Shaun; Sakamoto, Yoshifumi

    2015-10-01

    While the industry is making progress to offer EUV lithography schemes to attain ultimate critical dimensions down to 20 nm half pitch, an interim optical lithography solution to address an immediate need for resolution is offered by various integration schemes using advanced PSM (Phase Shift Mask) materials including thin e-beam resist and hard mask. Using the 193nm wavelength to produce 10nm or 7nm patterns requires a range of optimization techniques, including immersion and multiple patterning, which place a heavy demand on photomask technologies. Mask schemes with hard mask certainly help attain better selectivity and hence better resolution but pose integration challenges and defectivity issues. This paper presents a new photomask etch solution for attenuated phase shift masks that offers high selectivity (Cr:Resist > 1.5:1), tighter control on the CD uniformity with a 3sigma value approaching 1 nm and controllable CD bias (5-20 nm) with excellent CD linearity performance (<5 nm) down to the finer resolution. The new system has successfully demonstrated capability to meet the 10 nm node photomask CD requirements without the use of more complicated hard mask phase shift blanks. Significant improvement in post wet clean recovery performance was demonstrated by the use of advanced chamber materials. Examples of CD uniformity, linearity, and minimum feature size, and etch bias performance on 10 nm test site and production mask designs will be shown.

  14. Advanced refractory-metal and process technology for the fabrication of x-ray masks

    NASA Astrophysics Data System (ADS)

    Brooks, Cameron J.; Racette, Kenneth C.; Lercel, Michael J.; Powers, Lynn A.; Benoit, Douglas E.

    1999-06-01

    This paper provides an in-depth report of the advanced materials and process technology being developed for x-ray mask manufacturing at IBM. Masks using diamond membranes as replacement for silicon carbide are currently being fabricated. Alternate tantalum-based absorbers, such as tantalum boron, which offer improved etch resolution and critical dimension control, as well as higher x-ray absorption, are also being investigated. In addition to the absorber studies, the development of conductive chromium- based hard-mask films to replace the current silicon oxynitride layer is being explored. The progress of this advanced-materials work, which includes significant enhancements to x-ray mask image-placement performance, will be outlined.

  15. Optical double-image cryptography based on diffractive imaging with a laterally-translated phase grating.

    PubMed

    Chen, Wen; Chen, Xudong; Sheppard, Colin J R

    2011-10-10

    In this paper, we propose a method using structured-illumination-based diffractive imaging with a laterally-translated phase grating for optical double-image cryptography. An optical cryptosystem is designed, and multiple random phase-only masks are placed in the optical path. When a phase grating is laterally translated just before the plaintexts, several diffraction intensity patterns (i.e., ciphertexts) can be correspondingly obtained. During image decryption, an iterative retrieval algorithm is developed to extract plaintexts from the ciphertexts. In addition, security and advantages of the proposed method are analyzed. Feasibility and effectiveness of the proposed method are demonstrated by numerical simulation results. © 2011 Optical Society of America

  16. Information hiding based on double random-phase encoding and public-key cryptography.

    PubMed

    Sheng, Yuan; Xin, Zhou; Alam, Mohammed S; Xi, Lu; Xiao-Feng, Li

    2009-03-02

    A novel information hiding method based on double random-phase encoding (DRPE) and Rivest-Shamir-Adleman (RSA) public-key cryptosystem is proposed. In the proposed technique, the inherent diffusion property of DRPE is cleverly utilized to make up the diffusion insufficiency of RSA public-key cryptography, while the RSA cryptosystem is utilized for simultaneous transmission of the cipher text and the two phase-masks, which is not possible under the DRPE technique. This technique combines the complementary advantages of the DPRE and RSA encryption techniques and brings security and convenience for efficient information transmission. Extensive numerical simulation results are presented to verify the performance of the proposed technique.

  17. Balanced double-loop mesoscopic interferometer based on Josephson proximity nanojunctions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronzani, Alberto, E-mail: alberto.ronzani@nano.cnr.it; Altimiras, Carles; Giazotto, Francesco

    We report on the fabrication and characterization of a two-terminal mesoscopic interferometer based on three V/Cu/V Josephson junctions having nanoscale cross-section. The junctions have been arranged in a double-ring geometry realized by metallic thin film deposition through a suspended mask defined by electron beam lithography. Although a significant amount of asymmetry between the critical current of each junction is observed, we show that the interferometer is able to suppress the supercurrent to a level lower than 6 parts per thousand, being here limited by measurement resolution. The present nano-device is suitable for low-temperature magnetometric and gradiometric measurements over the micrometricmore » scale.« less

  18. Increased dead space in face mask continuous positive airway pressure in neonates.

    PubMed

    Hishikawa, Kenji; Fujinaga, Hideshi; Ito, Yushi

    2017-01-01

    Continuous positive airway pressure (CPAP) by face mask is commonly performed in newborn resuscitation. We evaluated the effect of face mask CPAP on system dead space. Face mask CPAP increases dead space. A CPAP model study. We estimated the volume of the inner space of the mask. We devised a face mask CPAP model, in which the outlet of the mask was covered with plastic; and three modified face mask CPAP models, in which holes were drilled near to the cushion of the covered face mask to alter the air exit. We passed a continuous flow of 21% oxygen through each model and we controlled the inner pressure to 5 cmH 2 O by adjusting the flow-relief valve. To evaluate the ventilation in the inner space of each model, we measured the oxygen concentration rise time, that is, the time needed for the oxygen concentration of each model to reach 35% after the oxygen concentration of the continuous flow was raised from 21% to 40%. The volume of inner space of the face mask was 38.3 ml. Oxygen concentration rise time in the face mask CPAP model was significantly longer at various continuous flow rates and points of the inner space of the face mask compared with that of the modified face mask CPAP model. Our study indicates that face mask CPAP leads to an increase in dead space and a decrease in ventilation efficiency under certain circumstances. Pediatr Pulmonol. 2017;52:107-111. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Optimal mask characterization by Surrogate Wafer Print (SWaP) method

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hoellein, Ingo; Peters, Jan Hendrick; Ackmann, Paul; Connolly, Brid; West, Craig

    2008-10-01

    Traditionally, definition of mask specifications is done completely by the mask user, while characterization of the mask relative to the specifications is done completely by the mask maker. As the challenges of low-k1 imaging continue to grow in scope of designs and in absolute complexity, the inevitable partnership between wafer lithographers and mask makers has strengthened as well. This is reflected in the jointly owned mask facilities and device manufacturers' continued maintenance of fully captive mask shops which foster the closer mask-litho relationships. However, while some device manufacturers have leveraged this to optimize mask specifications before the mask is built and, therefore, improve mask yield and cost, the opportunity for post-fabrication partnering on mask characterization is more apparent and compelling. The Advanced Mask Technology Center (AMTC) has been investigating the concept of assessing how a mask images, rather than the mask's physical attributes, as a technically superior and lower-cost method to characterize a mask. The idea of printing a mask under its intended imaging conditions, then characterizing the imaged wafer as a surrogate for traditional mask inspections and measurements represents the ultimate method to characterize a mask's performance, which is most meaningful to the user. Surrogate wafer print (SWaP) is already done as part of leading-edge wafer fab mask qualification to validate defect and dimensional performance. In the past, the prospect of executing this concept has generally been summarily discarded as technically untenable and logistically intractable. The AMTC published a paper at BACUS 2007 successfully demonstrating the performance of SWaP for the characterization of defects as an alternative to traditional mask inspection [1]. It showed that this concept is not only feasible, but, in some cases, desirable. This paper expands on last year's work at AMTC to assess the full implementation of SWaP as an enhancement to mask characterization quality including defectivity, dimensional control, pattern fidelity, and in-plane distortion. We present a thorough analysis of both the technical and logistical challenges coupled with an objective view of the advantages and disadvantages from both the technical and financial perspectives. The analysis and model used by the AMTC will serve to provoke other mask shops to prepare their own analyses then consider this new paradigm for mask characterization and qualification.

  20. Double-masked, randomized, dose-response study of AR-13324 versus latanoprost in patients with elevated intraocular pressure.

    PubMed

    Bacharach, Jason; Dubiner, Harvey B; Levy, Brian; Kopczynski, Casey C; Novack, Gary D

    2015-02-01

    AR-13324 is a small-molecule inhibitor of Rho kinase and a norepinephrine transporter. The objective of this 28-day study was to evaluate the ocular hypotensive efficacy and safety of AR-13324 ophthalmic solution compared with a positive control, latanoprost ophthalmic solution, in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Double-masked, randomized study in 22 private practice ophthalmology clinics. Participants were required to be adults with a diagnosis of OAG or OHT with unmedicated intraocular pressure (IOP) in the range of 22 to 36 mmHg. Patients were randomized to receive AR-13324 ophthalmic solution 0.01%, daily (pm), AR-13324 ophthalmic solution 0.02% daily (pm), or latanoprost 0.005% daily (pm) for 28 days. The primary efficacy endpoint was the mean diurnal IOP across subjects within the treatment group at day 28. Randomized and treated were 224 patients, 213 (95.1%) of whom completed the study. On day 28, mean diurnal IOP was 20.1, 20.0, and 18.7 mmHg in the AR-13324 0.01%, 0.02%, and latanoprost groups, respectively, representing a decrease from unmedicated baseline of 5.5, 5.7, and 6.8 mmHg (P<0.001). The 5.7-mmHg reduction in IOP by AR-13324 0.02% did not meet the criterion for noninferiority to latanoprost. The most frequently reported adverse event was conjunctival/ocular hyperemia, with a combined incidence of 52%, 57%, and 16%, respectively. On day 28 at 08:00 hours, the incidence of mild to moderate hyperemia by biomicroscopy was 18%, 24%, and 11%, respectively. AR-13324 0.02% was less effective than latanoprost by approximately 1 mmHg in patients with unmedicated IOPs of 22 to 35 mmHg. The major safety finding was ocular hyperemia, which was more common for both concentrations of AR-13324 than for latanoprost. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. The hypocholesterolemic effect of an antacid containing aluminum hydroxide.

    PubMed

    Sperber, A D; Henkin, Y; Zuili, I; Bearman, J E; Shany, S

    1991-12-01

    To evaluate the efficacy, safety, and hypocholesterolemic effect of an aluminum hydroxide-containing antacid in hypercholesterolemic individuals. A prospective, randomized, double-masked, placebo-controlled phase of 2 months' duration, followed by an open-design treatment phase of 2 months' duration and a washout phase of 2 months' duration. Family practice clinics of two rural communities (kibbutzim) in Israel. Fifty-six men and women with hypercholesterolemia (type IIa or IIb). Fifty individuals completed the study. After 2 months of dietary modification (low-fat, low-cholesterol diet), the participants were randomized into two matched groups. Group 1 (28 participants) was treated for 2 months with a chewable antacid tablet containing simethicone, magnesium hydroxide, and 113 mg of aluminum hydroxide per tablet, at a dose of two tablets four times daily. Group 2 (22 participants) was given a similar number of placebo tablets for 2 months. During the following 2 months, both groups received the antacid at the above dose. Lipoprotein levels were evaluated at baseline and every 2 months thereafter for 6 months. Compared with pretreatment levels, Group 1 experienced a decrease in low-density lipoprotein cholesterol (LDL-C) of 9.8% after 2 months (p less than 0.001) and 18.5% after 4 months (p less than 0.001). Compared with Group 2, the decrease in LDL-C in Group 1 was 6.2% at the end of the 2-month double-masked, placebo phase. Although the high-density lipoprotein cholesterol (HDL-C) was also reduced in Group 1 at the end of 4 months of therapy (10.2%), the HDL-C/LDL-C ratio increased by 13% during the same interval (p less than 0.05). The treatment was well tolerated, with minimal side effects. An aluminum hydroxide-containing antacid reduces LDL-C in hypercholesterolemic individuals. Although HDL-C was also reduced to a lesser extent, the overall atherogenic index was improved. Further studies should be conducted to evaluate the long-term safety and efficacy of antacids containing aluminum hydroxide in hypercholesterolemic patients.

  2. Double-masked, placebo-controlled safety and efficacy trial of diquafosol tetrasodium (INS365) ophthalmic solution for the treatment of dry eye.

    PubMed

    Tauber, J; Davitt, W F; Bokosky, J E; Nichols, K K; Yerxa, B R; Schaberg, A E; LaVange, L M; Mills-Wilson, M C; Kellerman, D J

    2004-11-01

    To investigate the safety and efficacy of diquafosol tetrasodium, a P2Y2 receptor agonist that stimulates fluid and mucin secretion on the ocular surface, as a novel topical treatment of dry eye disease. Subjects with dry eye (n=527) were evaluated in a randomized, double-masked, parallel-group trial comparing 24 weeks of treatment with 2 concentrations of diquafosol (1% and 2%) versus placebo instilled 4 times daily. Corneal staining, conjunctival staining, Schirmer tests, and subjective symptoms of dry eye were evaluated. Use of artificial tears was permitted as necessary. Subjects treated with 2% diquafosol had significantly lower corneal staining scores compared with placebo at the 6-week, primary efficacy time point (P<0.001), and superiority continued throughout the 24-week study. Reductions in corneal staining were observed as early as after 2 weeks of treatment, were maintained throughout the 24-week study, and were observed to worsen slightly (toward baseline) when diquafosol treatment was discontinued (week 25). Results for conjunctival staining were consistent with those observed for corneal staining. Schirmer scores at week 6 were significantly higher with diquafosol treatment than with placebo (P

  3. Methylxanthines enhance the effects of cocoa flavanols on cardiovascular function: randomized, double-masked controlled studies.

    PubMed

    Sansone, Roberto; Ottaviani, Javier I; Rodriguez-Mateos, Ana; Heinen, Yvonne; Noske, Dorina; Spencer, Jeremy P; Crozier, Alan; Merx, Marc W; Kelm, Malte; Schroeter, Hagen; Heiss, Christian

    2017-02-01

    Cocoa flavanol intake, especially that of (-)-epicatechin, has been linked to beneficial effects on human cardiovascular function. However, cocoa also contains the methylxanthines theobromine and caffeine, which may also affect vascular function. We sought to determine whether an interaction between cocoa flavanols and methylxanthines exists that influences cocoa flavanol-dependent vascular effects. Test drinks that contained various amounts of cocoa flavanols (0-820 mg) and methylxanthines (0-220 mg), either together or individually, were consumed by healthy volunteers (n = 47) in 4 different clinical studies-3 with a randomized, double-masked crossover design and 1 with 4 parallel crossover studies. Vascular status was assessed by measuring flow-mediated vasodilation (FMD), brachial pulse wave velocity (bPWV), circulating angiogenic cells (CACs), and blood pressure before and 2 h after the ingestion of test drinks. Although cocoa flavanol intake increased FMD 2 h after intake, the consumption of cocoa flavanols with methylxanthines resulted in a greater enhancement of FMD. Methylxanthine intake alone did not result in statistically significant changes in FMD. Cocoa flavanol ingestion alone decreased bPWV and diastolic blood pressure and increased CACs. Each of these changes was more pronounced when cocoa flavanols and methylxanthines were ingested together. It is important to note that the area under the curve of the plasma concentration of (-)-epicatechin metabolites over time was higher after the co-ingestion of cocoa flavanols and methylxanthines than after the intake of cocoa flavanols alone. Similar results were obtained when pure (-)-epicatechin and the methylxanthines theobromine and caffeine were consumed together. A substantial interaction between cocoa flavanols and methylxanthines exists at the level of absorption, in which the methylxanthines mediate an increased plasma concentration of (-)-epicatechin metabolites that coincides with enhanced vascular effects commonly ascribed to cocoa flavanol intake. This trial was registered at clinicaltrials.gov as NCT02149238. © 2017 American Society for Nutrition.

  4. Voice Quality After a Semi-Occluded Vocal Tract Exercise With a Ventilation Mask in Contemporary Commercial Singers: Acoustic Analysis and Self-Assessments.

    PubMed

    Fantini, Marco; Succo, Giovanni; Crosetti, Erika; Borragán Torre, Alfonso; Demo, Roberto; Fussi, Franco

    2017-05-01

    The current study aimed at investigating the immediate effects of a semi-occluded vocal tract exercise with a ventilation mask in a group of contemporary commercial singers. A randomized controlled study was carried out. Thirty professional or semi-professional singers with no voice complaints were randomly divided into two groups on recruitment: an experimental group and a control group. The same warm-up exercise was performed by the experimental group with an occluded ventilation mask placed over the nose and the mouth and by the control group without the ventilation mask. Voice was recorded before and after the exercise. Acoustic and self-assessment analysis were accomplished. The acoustic parameters of the voice samples recorded before and after training were compared, as well as the parameters' variations between the experimental and the control group. Self-assessment results of the experimental and the control group were compared too. Significant changes after the warm-up exercise included jitter, shimmer, and singing power ratio (SPR) in the experimental group. No significant changes were recorded in the control group. Significant differences between the experimental and the control group were found for ΔShimmer and ΔSPR. Self-assessment analysis confirmed a significantly higher phonatory comfort and voice quality perception for the experimental group. The results of the present study support the immediate advantageous effects on singing voice of a semi-occluded vocal tract exercise with a ventilation mask in terms of acoustic quality, phonatory comfort, and voice quality perception in contemporary commercial singers. Long-term effects still remain to be studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  5. Spatial Hearing, Attention and Informational Masking

    DTIC Science & Technology

    2015-10-26

    34 Meeting of the Northeast Music Cognition Group, Wesleyan University, Middletown, CT Kidd, G. Jr. and Mason, C.R. (2015) "Double entendre: embedding a... cognitive intrusions by competing sounds was explored on a linguistic level by varying syntactic structure and by using more formal means for varying...the work that was completed from 2012-2015 achieved its intended broad goal: our understanding of the auditory and cognitive processes underlying

  6. ACVP-03: Novel CD4+ T Cell Specific Immunohistochemistry Detection and Analysis Utilizing Masking of Not-T Cell CD4 in Fixed Tissues from Virally Infected and Uninfected Specimens | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Tissue Analysis Core (TAC) within the AIDS and Cancer Virus Program will process, embed, and perform microtomy on fixed tissue samples presented in ethanol. CD4 (DAB) and CD68/CD163 (FastRed) double immunohistochemistry will be performed, in whic

  7. Evaluation of the effects of botulinum toxin A injections when used to improve ease of care and comfort in children with cerebral palsy whom are non-ambulant: a double blind randomized controlled trial

    PubMed Central

    2012-01-01

    Background Children with cerebral palsy (CP) whom are non-ambulant are at risk of reduced quality of life and poor health status. Severe spasticity leads to discomfort and pain. Carer burden for families is significant. This study aims to determine whether intramuscular injections of botulinum toxin A (BoNT-A) combined with a regime of standard therapy has a positive effect on care and comfort for children with CP whom are non-ambulant (GMFCS IV/V), compared with standard therapy alone (cycle I), and whether repeated injections with the same regime of adjunctive therapy results in greater benefits compared with a single injecting episode (cycle II). The regime of therapy will include serial casting, splinting and/or provision of orthoses, as indicated, combined with four sessions of goal directed occupational therapy or physiotherapy. Method/design This study is a double blind randomized controlled trial. Forty participants will be recruited. In cycle I, participants will be randomized to either a treatment group who will receive BoNT-A injections into selected upper and/or lower limb muscles, or a control group who will undergo sham injections. Both groups will receive occupational therapy and /or physiotherapy following injections. Groups will be assessed at baseline then compared at 4 and 16 weeks following injections or sham control. Parents, treating clinicians and assessors will be masked to group allocation. In cycle II, all participants will undergo intramuscular BoNT-A injections to selected upper and/or lower limb muscles, followed by therapy. The primary outcome measure will be change in parent ratings in identified areas of concern for their child’s care and comfort, using the Canadian Occupational Performance Measure (COPM). Secondary measures will include the Care and Comfort Hypertonicity Scale (ease of care), the Cerebral Palsy Quality of Life Questionnaire (CP QoL–Child) (quality of life), the Caregiver Priorities and Child Health Index of Life with Disabilities Questionnaire (CPCHILD©) (health status) and the Paediatric Pain Profile (PPP) (pain). Adverse events will be carefully monitored by a clinician masked to group allocation. Discussion This paper outlines the theoretical basis, study hypotheses and outcome measures for a trial of BoNT-A injections and therapy for children with non-ambulant CP. Trial registration Australia New Zealand Clinical Trials Registry:N12609000360213 PMID:22873758

  8. Development for 2D pattern quantification method on mask and wafer

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Toyoda, Yasutaka; Wang, Zhigang

    2010-03-01

    We have developed the effective method of mask and silicon 2-dimensional metrology. The aim of this method is evaluating the performance of the silicon corresponding to Hotspot on a mask. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. 2-dimensional Shape quantification is important as optimal solution over these problems. Although 1-dimensional shape measurement has been performed by the conventional technique, 2-dimensional shape management is needed in the mass production line under the influence of RET. We developed the technique of analyzing distribution of shape edge performance as the shape management technique. On the other hand, there is roughness in the silicon shape made from a mass-production line. Moreover, there is variation in the silicon shape. For this reason, quantification of silicon shape is important, in order to estimate the performance of a pattern. In order to quantify, the same shape is equalized in two dimensions. And the method of evaluating based on the shape is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. It is possible to analyze variability of the edge of the same position with high precision. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. - Estimate of the correlativity of shape variability and a process margin. - Determination of two-dimensional variability of pattern. - Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the shape of the same location of Design, Mask, and Silicon in such a viewpoint.

  9. 3D-fabrication of tunable and high-density arrays of crystalline silicon nanostructures

    NASA Astrophysics Data System (ADS)

    Wilbers, J. G. E.; Berenschot, J. W.; Tiggelaar, R. M.; Dogan, T.; Sugimura, K.; van der Wiel, W. G.; Gardeniers, J. G. E.; Tas, N. R.

    2018-04-01

    In this report, a procedure for the 3D-nanofabrication of ordered, high-density arrays of crystalline silicon nanostructures is described. Two nanolithography methods were utilized for the fabrication of the nanostructure array, viz. displacement Talbot lithography (DTL) and edge lithography (EL). DTL is employed to perform two (orthogonal) resist-patterning steps to pattern a thin Si3N4 layer. The resulting patterned double layer serves as an etch mask for all further etching steps for the fabrication of ordered arrays of silicon nanostructures. The arrays are made by means of anisotropic wet etching of silicon in combination with an isotropic retraction etch step of the etch mask, i.e. EL. The procedure enables fabrication of nanostructures with dimensions below 15 nm and a potential density of 1010 crystals cm-2.

  10. Dissociating Consciousness from Inhibitory Control: Evidence for Unconsciously Triggered Response Inhibition in the Stop-Signal Task

    ERIC Educational Resources Information Center

    van Gaal, Simon; Ridderinkhof, K. Richard; van den Wildenberg, Wery P. M.; Lamme, Victor A. F.

    2009-01-01

    Theories about the functional relevance of consciousness commonly posit that higher order cognitive control functions, such as response inhibition, require consciousness. To test this assertion, the authors designed a masked stop-signal paradigm to examine whether response inhibition could be triggered and initiated by masked stop signals, which…

  11. LightLeaves: computer controlled kinetic reflection hologram installation and a brief discussion of earlier work

    NASA Astrophysics Data System (ADS)

    Connors Chen, Betsy

    2013-02-01

    LightLeaves is an installation combining leaf shaped, white light reflection holograms of landscape images with a special kinetic lighting device that houses a lamp and moving leaf shaped masks. The masks are controlled by an Arduino microcontroller and servomotors that position the masks in front of the illumination source of the holograms. The work is the most recent in a long series of landscapes that combine multi-hologram installations with computer controlled devices that play with the motion of the holograms, the light, sound or other elements in the work. LightLeaves was first exhibited at the Peabody Essex Museum in Salem, Massachusetts in a show titled "Eye Spy: Playing with Perception".

  12. Less is more: Neural activity during very brief and clearly visible exposure to phobic stimuli.

    PubMed

    Siegel, Paul; Warren, Richard; Wang, Zhishun; Yang, Jie; Cohen, Don; Anderson, Jason F; Murray, Lilly; Peterson, Bradley S

    2017-05-01

    Research on automatic processes in fear has emphasized the provocation of fear responses rather than their attenuation. We have previously shown that the repeated presentation of feared images without conscious awareness via backward masking reduces avoidance of a live tarantula in spider-phobic participants. Herein we investigated the neural basis for these adaptive effects of masked exposure. 21 spider-phobic and 21 control participants, identified by a psychiatric interview, fear questionnaire, and approaching a live tarantula, viewed stimuli in each of three conditions: (1) very brief exposure (VBE) to masked images of spiders, severely limited awareness; (2) clearly visible exposure (CVE) to spiders, full awareness; and (3) masked images of flowers (control), severely limited awareness. Only VBE to masked spiders generated neural activity more strongly in phobic than in control participants, within subcortical fear, attention, higher-order language, and vision systems. Moreover, VBE activated regions that support fear processing in phobic participants without causing them to experience fear consciously. Counter-intuitively, CVE to the same spiders generated stronger neural activity in control rather than phobic participants within these and other systems. CVE deactivated regions supporting fear regulation and caused phobic participants to experience fear. CVE-induced activations also correlated with measures of explicit fear ratings, whereas VBE-induced activations correlated with measures of implicit fear (color-naming interference of spider words). These multiple dissociations between the effects of VBE and CVE to spiders suggest that limiting awareness of exposure to phobic stimuli through visual masking paradoxically facilitates their processing, while simultaneously minimizing the experience of fear. Hum Brain Mapp 38:2466-2481, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Face mask use by patients in primary care.

    PubMed

    Tischendorf, Jessica S; Temte, Jonathan L

    2012-02-01

    Face masks are recommended for patients with respiratory symptoms to reduce influenza transmission. Little knowledge exists regarding actual utilization and acceptance of face masks in primary care. Compare distribution of face masks to clinic and community trends in respiratory infection (RI) and influenza-like illness (ILI); estimate the annual need for face masks in primary care. Retrospective observational study of practice data from a 31-week period starting in October 2009. Family practice clinic in Madison, Wis. Patients with fever, cough, or other respiratory symptoms as evaluated by reception staff. Age, sex, and weekly counts of individuals receiving a face mask, as well as counts of RI and ILI patients based on ICD-9 coding from 27 statewide clinics. Face mask counts were 80% of RI counts for the clinic and reflected the demographics of the clinic population. Distribution was correlated to prevalence of RI (R = 0.783, P < 0.001) and ILI (R = 0.632, P < 0.001). Annually, 8% of clinic visits were for RI. The high percentage of face mask use among RI patients reflects the feasibility of this intervention to help control influenza transmission in a primary care setting. Using the present data, clinics can estimate the annual need for face masks.

  14. Paving the way to a full chip gate level double patterning application

    NASA Astrophysics Data System (ADS)

    Haffner, Henning; Meiring, Jason; Baum, Zachary; Halle, Scott

    2007-10-01

    Double patterning lithography processes can offer significant yield enhancement for challenging circuit designs. Many decomposition (i.e. the process of dividing the layout design into first and second exposures) techniques are possible, but the focus of this paper is on the use of a secondary "cut" mask to trim away extraneous features left from the first exposure. This approach has the advantage that each exposure only needs to support a subset of critical features (e.g. dense lines with the first exposure, isolated spaces with the second one). The extraneous features ("printing assist features" or PrAFs) are designed to support the process window of critical features much like the role of the subresolution assist features (SRAFs) in conventional processes. However, the printing nature of PrAFs leads to many more design options, and hence a greater process and decomposition parameter exploration space, than are available for SRAFs. A decomposition scheme using PRAFs was developed for a gate level process. A critical driver of the work was to deliver improved across-chip linewidth variation (ACLV) performance versus an optimized single exposure process while providing support for a larger range of critical features. A variety of PRAF techniques were investigated by simulation, with a PrAF scheme similar to standard SRAF rules being chosen as the optimal solution [1]. This paper discusses aspects of the code development for an automated PrAF generation and placement scheme and the subsequent decomposition of a layout into two mask levels. While PrAF placement and decomposition is straightforward for layouts with pitch and orientation restrictions, it becomes rather complex for unrestricted layout styles. Because this higher complexity yields more irregularly shaped PrAFs, mask making becomes another critical driver of the optimum placement and clean-up strategies. Examples are given of how those challenges are met or can be successfully circumvented. During subsequent decomposition of the PrAF-enhanced layout into two independent mask levels, various geometric decomposition parameters have to be considered. As an example, the removal of PrAFs has to be guaranteed by a minimum required overlap of the cut mask opening past any PrAF edge. It is discussed that process assumptions such as CD tolerances and overlay as well as inter-level relationship ground rules need to be considered to successfully optimize the final decomposition scheme. Furthermore, simulation and experimental results regarding not only ACLV but also across-device linewidth variation (ADLV) are analyzed.

  15. Dynamic mask for producing uniform or graded-thickness thin films

    DOEpatents

    Folta, James A [Livermore, CA

    2006-06-13

    A method for producing single layer or multilayer films with high thickness uniformity or thickness gradients. The method utilizes a moving mask which blocks some of the flux from a sputter target or evaporation source before it deposits on a substrate. The velocity and position of the mask is computer controlled to precisely tailor the film thickness distribution. The method is applicable to any type of vapor deposition system, but is particularly useful for ion beam sputter deposition and evaporation deposition; and enables a high degree of uniformity for ion beam deposition, even for near-normal incidence of deposition species, which may be critical for producing low-defect multilayer coatings, such as required for masks for extreme ultraviolet lithography (EUVL). The mask can have a variety of shapes, from a simple solid paddle shape to a larger mask with a shaped hole through which the flux passes. The motion of the mask can be linear or rotational, and the mask can be moved to make single or multiple passes in front of the substrate per layer, and can pass completely or partially across the substrate.

  16. Twisted multifilament superconductor

    NASA Technical Reports Server (NTRS)

    Coles, W. D. (Inventor)

    1973-01-01

    Masking selected portions of a ribbon and forming an intermetallic compound on the unmasked portions by a controlled diffusion reaction produces a twisted filamentary structure. The masking material prohibits the formation of superconductive material on predetermined areas of the substrate.

  17. Anticipating and controlling mask costs within EDA physical design

    NASA Astrophysics Data System (ADS)

    Rieger, Michael L.; Mayhew, Jeffrey P.; Melvin, Lawrence S.; Lugg, Robert M.; Beale, Daniel F.

    2003-08-01

    For low k1 lithography, more aggressive OPC is being applied to critical layers, and the number of mask layers with OPC treatments is growing rapidly. The 130 nm, process node required, on average, 8 layers containing rules- or model-based OPC. The 90 nm node will have 16 OPC layers, of which 14 layers contain aggressive model-based OPC. This escalation of mask pattern complexity, coupled with the predominant use of vector-scan e-beam (VSB) mask writers contributes to the rising costs of advanced mask sets. Writing times for OPC layouts are several times longer than for traditional layouts, making mask exposure the single largest cost component for OPC masks. Lower mask yields, another key factor in higher mask costs, is also aggravated by OPC. Historical mask set costs are plotted below. The initial cost of a 90 nm-node mask set will exceed one million dollars. The relative impact of mask cost on chip depends on how many total wafers are printed with each mask set. For many foundry chips, where unit production is often well below 1000 wafers, mask costs are larger than wafer processing costs. Further increases in NRE may begin to discourage these suppliers' adoption to 90 nm and smaller nodes. In this paper we will outline several alternatives for reducing mask costs by strategically leveraging dimensional margins. Dimensional specifications for a particular masking layer usually are applied uniformly to all features on that layer. As a practical matter, accuracy requirements on different features in the design may vary widely. Take a polysilicon layer, for example: global tolerance specifications for that layer are driven by the transistor-gate requirements; but these parameters over-specify interconnect feature requirements. By identifying features where dimensional accuracy requirements can be reduced, additional margin can be leveraged to reduce OPC complexity. Mask writing time on VSB tools will drop in nearly direct proportion to reduce shot count. By inspecting masks with reference to feature-dependent margins, instead of uniform specifications, mask yield can be effectively increased further reducing delivered mask expense.

  18. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and nasal pillow masks for the treatment of obstructive sleep apnea. J Clin Sleep Med 2016;12(9):1263–1268. PMID:27448430

  19. PMJ panel discussion overview on mask complexities, cost, and cycle time in 32-nm system LSI generation: conflict or concurrent?

    NASA Astrophysics Data System (ADS)

    Hosono, Kunihiro; Kato, Kokoro

    2008-10-01

    This is a report on a panel discussion organized in Photomask Japan 2008, where the challenges about "Mask Complexities, Cost, and Cycle Time in 32-nm System LSI Generation" were addressed to have a look over the possible solutions from the standpoints of chipmaker, commercial mask shop, DA tool vendor and equipments makers. The wrap-up is as follows: Mask complexities justify the mask cost, while the acceptable increase rate of 32nm-mask cost significantly differs between mask suppliers or users side. The efficiency progress by new tools or DFM has driven their cycle-time reductions. Mask complexities and cost will be crucial issues prior to cycle time, and there seems to be linear correlation between them. Controlling complexity and cycle time requires developing a mix of advanced technologies, and especially for cost reduction, shot prices in writers and processing rates in inspection tools have been improved remarkably by tool makers. In addition, activities of consortium in Japan (Mask D2I) are expected to enhance the total optimization of mask design, writing and inspection. The cycle-time reduction potentially drives the lowering of mask cost, and, on the other, the pattern complexities and tighter mask specifications get in the way to 32nm generation as well as the nano-economics and market challenges. There are still many difficult problems in mask manufacturing now, and we are sure to go ahead to overcome a 32nm hurdle with the advances of technologies and collaborations by not only technologies but also finance.

  20. High-numerical aperture extreme ultraviolet scanner for 8-nm lithography and beyond

    NASA Astrophysics Data System (ADS)

    Schoot, Jan van; Setten, Eelco van; Rispens, Gijsbert; Troost, Kars Z.; Kneer, Bernhard; Migura, Sascha; Neumann, Jens Timo; Kaiser, Winfried

    2017-10-01

    Current extreme ultraviolet (EUV) projection lithography systems exploit a projection lens with a numerical aperture (NA) of 0.33. It is expected that these will be used in mass production in the 2018/2019 timeframe. By then, the most difficult layers at the 7-nm logic and the mid-10-nm DRAM nodes will be exposed. These systems are a more economical alternative to multiple-exposure by 193 argon fluoride immersion scanners. To enable cost-effective shrink by EUV lithography down to 8-nm half pitch, a considerably larger NA is needed. As a result of the increased NA, the incidence angles of the light rays at the mask increase significantly. Consequently, the shadowing and the variation of the multilayer reflectivity deteriorate the aerial image contrast to unacceptably low values at the current 4× magnification. The only solution to reduce the angular range at the mask is to increase the magnification. Simulations show that the magnification has to be doubled to 8× to overcome the shadowing effects. Assuming that the mask infrastructure will not change the mask form factor, this would inevitably lead to a field size that is a quarter of the field size of the current 0.33-NA step and scan systems and reduce the throughput (TPT) of the high-NA scanner to a value below 100 wafers per hour unless additional measures are taken. This paper presents an anamorphic step and scan system capable of printing fields that are half the field size of the current full field. The anamorphic system has the potential to achieve a TPT in excess of 150 wafers per hour by increasing the transmission of the optics, as well as increasing the acceleration of the wafer stage and mask stage. This makes it an economically viable lithography solution.

  1. Nanoimprint wafer and mask tool progress and status for high volume semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Matsuoka, Yoichi; Seki, Junichi; Nakayama, Takahiro; Nakagawa, Kazuki; Azuma, Hisanobu; Yamamoto, Kiyohito; Sato, Chiaki; Sakai, Fumio; Takabayashi, Yukio; Aghili, Ali; Mizuno, Makoto; Choi, Jin; Jones, Chris E.

    2016-10-01

    Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash* Imprint Lithography (J-FIL*) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed, leaving a patterned resist on the substrate. There are many criteria that determine whether a particular technology is ready for wafer manufacturing. Defectivity and mask life play a significant role relative to meeting the cost of ownership (CoO) requirements in the production of semiconductor devices. Hard particles on a wafer or mask create the possibility of inducing a permanent defect on the mask that can impact device yield and mask life. By using material methods to reduce particle shedding and by introducing an air curtain system, the lifetime of both the master mask and the replica mask can be extended. In this work, we report results that demonstrate a path towards achieving mask lifetimes of better than 1000 wafers. On the mask side, a new replication tool, the FPA-1100 NR2 is introduced. Mask replication is required for nanoimprint lithography (NIL), and criteria that are crucial to the success of a replication platform include both particle control, resolution and image placement accuracy. In this paper we discuss the progress made in both feature resolution and in meeting the image placement specification for replica masks.

  2. Efficacy of a new device to optimize positive pressure ventilation via face mask in edentulous patients: a randomized trial.

    PubMed

    Niño, Maria C; Pauwels, Andres; Raffan, Fernando; Arango, Enrique; Romero, David J; Benitez, Daniel

    2017-04-01

    Mask ventilation is routinely performed during anesthesia. Under some circumstances, it might be difficult to perform, such as in edentulous patients, due to inadequate mask seal. We developed a new device called NIPARA and studied its use For ventilation optimization in edentulous patients. This randomized controlled trial included edentulous adults who had no other predictors of difficult airway, scheduled to undergo general anesthesia. Patients were assigned either to the NIPARA device group or to the control group (oral airway only). The primary outcomes were peak inspiratory pressure and tidal volume values of the first 14 breaths. The secondary outcome was the incidence of complications. Data from 37 patients were collected during a one-year period (twenty in the NIPARA device group and 17 in the control group). The difference in mean PIP was not statistically significant. The tidal volume was 1.5 times greater in the NIPARA group than in the control group. One patient from the intervention group had minimal oral trauma. In the administration of face mask ventilation, NIPARA is an effective device that significantly improves the tidal volume administered in edentulous patients.

  3. Fabrication of rectangular cross-sectional microchannels on PMMA with a CO2 laser and underwater fabricated copper mask

    NASA Astrophysics Data System (ADS)

    Prakash, Shashi; Kumar, Subrata

    2017-09-01

    CO2 lasers are commonly used for fabricating polymer based microfluidic devices. Despite several key advantages like low cost, time effectiveness, easy to operate and no requirement of clean room facility, CO2 lasers suffer from few disadvantages like thermal bulging, improper dimensional control, difficulty to produce microchannels of other than Gaussian cross sectional shapes and inclined surface walls. Many microfluidic devices require square or rectangular cross-sections which are difficult to produce using normal CO2 laser procedures. In this work, a thin copper sheet of 40 μm was used as a mask above the PMMA (Polymethyl-methacrylate) substrate while fabricating the microchannels utilizing the raster scanning feature of the CO2 lasers. Microchannels with different width dimensions were fabricated utilizing a CO2 laser in with mask and without-mask conditions. A comparison of both the fabricating process has been made. It was found that microchannels with U shape cross section and rectangular cross-section can efficiently be produced using the with mask technique. In addition to this, this technique can provide perfect dimensional control and better surface quality of the microchannel walls. Such a microchannel fabrication process do not require any post-processing. The fabrication of mask using a nanosecond fiber laser has been discussed in details. An underwater laser fabrication method was adopted to overcome heat related defects in mask preparation. Overall, the technique was found to be easy to adopt and significant improvements were observed in microchannel fabrication.

  4. Quantification of mammographic masking risk with volumetric breast density maps: how to select women for supplemental screening

    NASA Astrophysics Data System (ADS)

    Holland, Katharina; van Gils, Carla H.; Wanders, Johanna OP; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    The sensitivity of mammograms is low for women with dense breasts, since cancers may be masked by dense tissue. In this study, we investigated methods to identify women with density patterns associated with a high masking risk. Risk measures are derived from volumetric breast density maps. We used the last negative screening mammograms of 93 women who subsequently presented with an interval cancer (IC), and, as controls, 930 randomly selected normal screening exams from women without cancer. Volumetric breast density maps were computed from the mammograms, which provide the dense tissue thickness at each location. These were used to compute absolute and percentage glandular tissue volume. We modeled the masking risk for each pixel location using the absolute and percentage dense tissue thickness and we investigated the effect of taking the cancer location probability distribution (CLPD) into account. For each method, we selected cases with the highest masking measure (by thresholding) and computed the fraction of ICs as a function of the fraction of controls selected. The latter can be interpreted as the negative supplemental screening rate (NSSR). Between the models, when incorporating CLPD, no significant differences were found. In general, the methods performed better when CLPD was included. At higher NSSRs some of the investigated masking measures had a significantly higher performance than volumetric breast density. These measures may therefore serve as an alternative to identify women with a high risk for a masked cancer.

  5. Evidence for differential modulation of primary and nonprimary auditory cortex by forward masking in tinnitus.

    PubMed

    Roberts, Larry E; Bosnyak, Daniel J; Bruce, Ian C; Gander, Phillip E; Paul, Brandon T

    2015-09-01

    It has been proposed that tinnitus is generated by aberrant neural activity that develops among neurons in tonotopic of regions of primary auditory cortex (A1) affected by hearing loss, which is also the frequency region where tinnitus percepts localize (Eggermont and Roberts 2004; Roberts et al., 2010, 2013). These models suggest (1) that differences between tinnitus and control groups of similar age and audiometric function should depend on whether A1 is probed in tinnitus frequency region (TFR) or below it, and (2) that brain responses evoked from A1 should track changes in the tinnitus percept when residual inhibition (RI) is induced by forward masking. We tested these predictions by measuring (128-channel EEG) the sound-evoked 40-Hz auditory steady-state response (ASSR) known to localize tonotopically to neural sources in A1. For comparison the N1 transient response localizing to distributed neural sources in nonprimary cortex (A2) was also studied. When tested under baseline conditions where tinnitus subjects would have heard their tinnitus, ASSR responses were larger in a tinnitus group than in controls when evoked by 500 Hz probes while the reverse was true for tinnitus and control groups tested with 5 kHz probes, confirming frequency-dependent group differences in this measure. On subsequent trials where RI was induced by masking (narrow band noise centered at 5 kHz), ASSR amplitude increased in the tinnitus group probed at 5 kHz but not in the tinnitus group probed at 500 Hz. When collapsed into a single sample tinnitus subjects reporting comparatively greater RI depth and duration showed comparatively larger ASSR increases after masking regardless of probe frequency. Effects of masking on ASSR amplitude in the control groups were completely reversed from those in the tinnitus groups, with no change seen to 5 kHz probes but ASSR increases to 500 Hz probes even though the masking sound contained no energy at 500 Hz (an "off-frequency" masking effect). In contrast to these findings for the ASSR, N1 amplitude was larger in tinnitus than control groups at both probe frequencies under baseline conditions, decreased after masking in all conditions, and did not relate to RI. These results suggest that aberrant neural activity occurring in the TFR of A1 underlies tinnitus and its modulation during RI. They indicate further that while neural changes occur in A2 in tinnitus, these changes do not reflect the tinnitus percept. Models for tinnitus and forward masking are described that integrate these findings within a common framework. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.

    PubMed

    Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M

    2015-07-01

    If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants <33 weeks gestational age in the delivery room. Infants born at the Royal Alexandra Hospital from April to September 2013 at <33 weeks gestational age who received mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.

  7. Abnormal spatial frequency channels in esotropic cats.

    PubMed

    Holopigian, K; Blake, R

    1984-01-01

    A noise masking paradigm was used to measure spatial tuning for the deviating and nondeviating eyes of two esotropic cats and for one eye of a control cat. With increasing noise contrast, masking grew more slowly for both the deviating and the nondeviating eyes of the esotropic cats than for the control cat; apparently, contrast coding is impaired for both eyes of the esotropic cats. Masking with band-reject filtered noise indicated that detection channels for either eye of the esotropic cats were twice as broadly tuned as those for the control cat. In a subsequent experiment, the spatial tuning characteristics of two human esotropes were found to be normal, indicating a fundamental difference between human esotropia and esotropia induced in cats by the section of an eye muscle.

  8. [Clinical study of the effectiveness of a dexpanthenol containing artificial tears solution (Siccaprotect) in treatment of dry eyes].

    PubMed

    Göbbels, M; Gross, D

    1996-01-01

    In this controlled, randomized, double-masked study the effect of dexpanthenol-containing artificial tears (Siccaprotect) on patients with dry eyes was examined. 50 patients applied either dexpanthenol-containing artificial tears (Siccaprotect) or the identical, but free of dexpanthenol, eye drops five times daily into the conjunctival sac. No other ophthalmics were administered. The corneal epithelial permeability was measured by fluorophotometry and Schirmer-Test, Rose Bengal staining, tear film break-up time and the patients' subjective complaints were determined before and after 6 weeks of treatment. The dexpanthenol-containing artificial tears (Siccaprotect) improved disturbances of the corneal epithelial permeability significantly in comparison to the dexpanthenol-free eyes drops. The other parameters didn't show relevant differences. These data suggest that, in dry eyes, treatment with dexpanthenol-containing eye drops leads to a favorable and comparing with dexpanthenol-free eye drops superior improvement in disturbances of corneal epithelium permeability.

  9. Community-based recruitment strategies for a longitudinal interventional study: the VECAT experience.

    PubMed

    Garrett, S K; Thomas, A P; Cicuttini, F; Silagy, C; Taylor, H R; McNeil, J J

    2000-05-01

    This article examines different recruitment strategies for the VECAT Study, a 4-year, double-masked, placebo-controlled, randomized clinical trial of vitamin E in the prevention of cataract and age-related maculopathy. Five recruitment methods were employed: newspaper advertising, radio advertising, approaches to community groups, approaches via general practices, and an electoral roll mail-out. Participants (1204) from the community in Melbourne, Australia were recruited and enrolled within 15 months (age range: 55-80 years, mean 66 years; gender ratio: 57% female, 43% male). The electoral roll mail-out and newspaper advertising were the most efficient methods of recruitment in terms of absolute numbers of participants recruited and cost per participant. Recruitment for the VECAT study was successfully completed within the planned period. Although the electoral roll mail-out and newspaper advertising were the most efficient for this study, other methods may be of value for studies with different subject selection criteria.

  10. Using a high-flow nasal cannula provides superior results to OxyMask delivery in moderate to severe bronchiolitis: a randomized controlled study.

    PubMed

    Ergul, Ayse Betul; Calıskan, Emrah; Samsa, Hasan; Gokcek, Ikbal; Kaya, Ali; Zararsiz, Gozde Erturk; Torun, Yasemin Altuner

    2018-06-18

    The effectiveness of using a face mask with a small diffuser for oxygen delivery (OxyMask) was compared to use of a high-flow nasal cannula (HFNC) in patients with moderate or severe bronchiolitis.The study population in this open, phase 4, randomized controlled trial consisted of 60 patients aged 1-24 months diagnosed with moderate or severe bronchiolitis and admitted to an intensive care unit (ICU) for oxygen therapy. The patients were randomized into two groups according to the method of oxygen delivery: a diffuser mask group and an HFNC group.There were seven failures in the mask group and none in the HFNC group. The survival probability differed significantly between the two treatment methods (p = 0.009).Time to weaning off oxygen therapy was 56 h in the HFNC group and 96 h in the mask group (p < 0.001). HFNC use decreased the treatment failure rate and the duration of both oxygen therapy and ICU treatment compared to the diffuser mask, which implies that an HFNC should be the first choice for treating patients admitted to the ICU with severe bronchiolitis. What is known: • A high-flow nasal cannula (HFNC) does not significantly reduce the time on oxygen compared to standard therapy in children with moderate to severe bronchiolitis. Observational studies show that, since the introduction of HFNC, fewer children with bronchiolitis need intubation. For children with moderate to severe bronchiolitis there is no proof of its benefit. What Is New: • In children with moderate to severe bronchiolitis, HFNC provides faster and more effective improvement than can be achieved with a diffuser mask.

  11. Writing time estimation of EB mask writer EBM-9000 for hp16nm/logic11nm node generation

    NASA Astrophysics Data System (ADS)

    Kamikubo, Takashi; Takekoshi, Hidekazu; Ogasawara, Munehiro; Yamada, Hirokazu; Hattori, Kiyoshi

    2014-10-01

    The scaling of semiconductor devices is slowing down because of the difficulty in establishing their functionality at the nano-size level and also because of the limitations in fabrications, mainly the delay of EUV lithography. While multigate devices (FinFET) are currently the main driver for scalability, other types of devices, such as 3D devices, are being realized to relax the scaling of the node. In lithography, double or multiple patterning using ArF immersion scanners is still a realistic solution offered for the hp16nm node fabrication. Other lithography candidates are those called NGL (Next Generation Lithography), such as DSA (Directed-Self-Assembling) or nanoimprint. In such situations, shot count for mask making by electron beam writers will not increase. Except for some layers, it is not increasing as previously predicted. On the other hand, there is another aspect that increases writing time. The exposure dose for mask writing is getting higher to meet tighter specifications of CD uniformity, in other words, reduce LER. To satisfy these requirements, a new electron beam mask writer, EBM-9000, has been developed for hp16nm/logic11nm generation. Electron optical system, which has the immersion lens system, was evolved from EBM-8000 to achieve higher current density of 800A/cm2. In this paper, recent shot count and dose trend are discussed. Also, writing time is estimated for the requirements in EBM-9000.

  12. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis

    PubMed Central

    Smith, Jeffrey D.; MacDougall, Colin C.; Johnstone, Jennie; Copes, Ray A.; Schwartz, Brian; Garber, Gary E.

    2016-01-01

    Background: Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. Methods: We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case–control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. Results: We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case–control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64–1.24; cohort study: OR 0.43, 95% CI 0.03–6.41; case–control studies: OR 0.91, 95% CI 0.25–3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19–1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57–1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Interpretation: Although N95 respirators appeared to have a protective advantage over surgical masks in laboratory settings, our meta-analysis showed that there were insufficient data to determine definitively whether N95 respirators are superior to surgical masks in protecting health care workers against transmissible acute respiratory infections in clinical settings. PMID:26952529

  13. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis.

    PubMed

    Smith, Jeffrey D; MacDougall, Colin C; Johnstone, Jennie; Copes, Ray A; Schwartz, Brian; Garber, Gary E

    2016-05-17

    Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case-control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case-control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64-1.24; cohort study: OR 0.43, 95% CI 0.03-6.41; case-control studies: OR 0.91, 95% CI 0.25-3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19-1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57-1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Although N95 respirators appeared to have a protective advantage over surgical masks in laboratory settings, our meta-analysis showed that there were insufficient data to determine definitively whether N95 respirators are superior to surgical masks in protecting health care workers against transmissible acute respiratory infections in clinical settings. © 2016 Canadian Medical Association or its licensors.

  14. Optically secured information retrieval using two authenticated phase-only masks.

    PubMed

    Wang, Xiaogang; Chen, Wen; Mei, Shengtao; Chen, Xudong

    2015-10-23

    We propose an algorithm for jointly designing two phase-only masks (POMs) that allow for the encryption and noise-free retrieval of triple images. The images required for optical retrieval are first stored in quick-response (QR) codes for noise-free retrieval and flexible readout. Two sparse POMs are respectively calculated from two different images used as references for authentication based on modified Gerchberg-Saxton algorithm (GSA) and pixel extraction, and are then used as support constraints in a modified double-phase retrieval algorithm (MPRA), together with the above-mentioned QR codes. No visible information about the target images or the reference images can be obtained from each of these authenticated POMs. This approach allows users to authenticate the two POMs used for image reconstruction without visual observation of the reference images. It also allows user to friendly access and readout with mobile devices.

  15. Optically secured information retrieval using two authenticated phase-only masks

    PubMed Central

    Wang, Xiaogang; Chen, Wen; Mei, Shengtao; Chen, Xudong

    2015-01-01

    We propose an algorithm for jointly designing two phase-only masks (POMs) that allow for the encryption and noise-free retrieval of triple images. The images required for optical retrieval are first stored in quick-response (QR) codes for noise-free retrieval and flexible readout. Two sparse POMs are respectively calculated from two different images used as references for authentication based on modified Gerchberg-Saxton algorithm (GSA) and pixel extraction, and are then used as support constraints in a modified double-phase retrieval algorithm (MPRA), together with the above-mentioned QR codes. No visible information about the target images or the reference images can be obtained from each of these authenticated POMs. This approach allows users to authenticate the two POMs used for image reconstruction without visual observation of the reference images. It also allows user to friendly access and readout with mobile devices. PMID:26494213

  16. Optically secured information retrieval using two authenticated phase-only masks

    NASA Astrophysics Data System (ADS)

    Wang, Xiaogang; Chen, Wen; Mei, Shengtao; Chen, Xudong

    2015-10-01

    We propose an algorithm for jointly designing two phase-only masks (POMs) that allow for the encryption and noise-free retrieval of triple images. The images required for optical retrieval are first stored in quick-response (QR) codes for noise-free retrieval and flexible readout. Two sparse POMs are respectively calculated from two different images used as references for authentication based on modified Gerchberg-Saxton algorithm (GSA) and pixel extraction, and are then used as support constraints in a modified double-phase retrieval algorithm (MPRA), together with the above-mentioned QR codes. No visible information about the target images or the reference images can be obtained from each of these authenticated POMs. This approach allows users to authenticate the two POMs used for image reconstruction without visual observation of the reference images. It also allows user to friendly access and readout with mobile devices.

  17. Reticle haze: an industrial approach

    NASA Astrophysics Data System (ADS)

    Gough, Stuart; Gérard, Xavier; Bichebois, Pascal; Roche, Agnès; Sundermann, Frank; Guyader, Véronique; Bièron, Yann; Galvier, Jean; Nicoleau, Serge

    2007-02-01

    Crystal growth on advanced reticles is currently a world wide industrial problem in high end semiconductor production environment, crystals are mainly found on reticles that use high energy photons at 193nm wavelength. The most common crystals to be found on masks are ammonium sulphate, a combination of sulphate, from maskshop residues after clean, pellicle materials and storage conditions and amines from clean room, tool and storage environments. High energy photons act as a catalyst to form crystals on both the pattern side as well as the backglass surface. After a number of exposures crystals can grow in size and eventually become printable. In order to detect HAZE before critical dimensions have been reached suitable detection methods need to be implemented to ensure image integrity. These detection methods are different and complementary depending on the surface to be inspected. Once crystals have started growing, the only method to regain mask quality is to clean the mask at the manufacturers site. This brings with it several undesirable situations, not only is the mask unavailable for production but the cleaning of a mask leads to a potential risk of damaging the mask especially for sub resolution patterns such as scatter bars and phase and transmission changes for eaPSM (Embedded Attenuated Phase Shift Mask) masks. This paper will discuss the initial haze issues seen in a 300mm wafer fab and actions put in place to address the problem. An explanation of results gained from haze reduction actions implemented in a wafer fab will be given. Haze seen by reticle inspection and surface analysis tools can be characterised by typical contamination patterns. These signatures appear after a certain number of wafers exposed depending on several reticle variables such as transmission, Binary, eaPSM, Pellicle. Details will be given of how reticles are managed to ensure minimum impact to a production environment with an appropriate reticle control plan. AMC (Airborne Molecular Contamination) in wafer fab and equipment environment is a key factor for crystal growth. The type of filtration installed to reduce AMC and method of atmospheric monitoring for critical areas will be explained. Choice of reticle storage conditions and materials used for transport during the life of the reticle will be included. Improvements in maskshop cleaning processes, reticle materials and environmental control have lead to extended mask lifetime in the wafer fab of more than 20 times. The fundamental differences and relative monitoring will be described and gain from implemented actions will be presented Once crystals have started growing, the only method to regain mask quality is to clean the mask at the manufacturers site. This brings with it several undesirable situations, not only is the mask unavailable for production but the cleaning of a mask leads to a potential risk of damaging the mask especially for sub resolution patterns such as scatter bars and phase and transmission changes for eaPSM (Embedded Attenuated Phase Shift Mask) masks. This paper will discuss the initial haze issues seen in a 300mm wafer fab and actions put in place to address the problem. An explanation of results gained from haze reduction actions implemented in a wafer fab will be given. Haze seen by reticle inspection and surface analysis tools can be characterised by typical contamination patterns. These signatures appear after a certain number of wafers exposed depending on several reticle variables such as transmission, Binary, eaPSM, Pellicle. Details will be given of how reticles are managed to ensure minimum impact to a production environment with an appropriate reticle control plan. AMC (Airborne Molecular Contamination) in wafer fab and equipment environment is a key factor for crystal growth. The type of filtration installed to reduce AMC and method of atmospheric monitoring for critical areas will be explained. Choice of reticle storage conditions and materials used for transport during the life of the reticle will be included. Improvements in maskshop cleaning processes, reticle materials and environmental control have lead to extended mask lifetime in the wafer fab of more than 20 times. The fundamental differences and relative monitoring will be described and gain from implemented actions will be presented

  18. A randomised controlled trial comparing ProSeal laryngeal mask airway, i-gel and Laryngeal Tube Suction-D under general anaesthesia for elective surgical patients requiring controlled ventilation.

    PubMed

    Das, Bikramjit; Varshney, Rahul; Mitra, Subhro

    2017-12-01

    The ProSeal™ laryngeal mask airway (PLMA), i-gel™ and Laryngeal Tube Suction-D (LTS-D™) have previously been evaluated alone or in pair-wise comparisons but differing study designs make it difficult to compare the results. The aim of this study was to compare the clinical performance of these three devices in terms of efficacy and safety in patients receiving mechanical ventilation during elective surgical procedures. This prospective, randomised, double-blind study was conducted on 150 American Society of Anesthesiologists physical status I-II patients, randomly allocated into 3 groups, undergoing elective surgical procedures under general anaesthesia. PLMA, i-gel™ or LTS-D™ appropriate for weight or/and height was inserted. Primary outcome measured was airway sealing pressure. Insertion time, ease of insertion, number of attempts, overall success rate and the incidence of airway trauma and complications were also recorded. Intergroup differences were compared using one-way analysis of variance with post hoc correction for continuous data and Chi-square test for categorical variables. Overall success rate was comparable between the three devices (i-gel™ 100%, LTS-D™ 94%, PLMA 96%). Airway sealing pressure was lower with i-gel™ (23.38 ± 2.06 cm H 2 O) compared to LTS-D™ (26.06 ± 2.11 cm H 2 O) and PLMA (28.5 ± 2.8 cm H 2 O; P < 0.0005). The mean insertion time was significantly more in PLMA (38.77 ± 3.2 s) compared to i-gel™ (27.9 ± 2.53 s) and LTS-D™ (21.66 ± 2.31 s; P < 0.0005). Airway sealing pressure and insertion time were significantly higher in PLMA compared to i-gel™ and LTS-D™.

  19. New mask technology challenges

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.

    2001-09-01

    Mask technology development has accelerated dramatically in recent years from the glacial pace of the last three decades to the rapid and sometimes simultaneous introductions of new wavelengths and mask-based resolution enhancement techniques. The nature of the semiconductor business has also become one driven by time-to-market as an overwhelming factor in capturing market share and profit. These are among the factors that have created enormous stress on the mask industry to produce masks with enhanced capabilities, such as phase-shifting attenuators, sub-resolution assist bars, and optical proximity correction (OPC) features, while maintaining or reducing cost and cycle time. The mask can no longer be considered a commodity item that is purchased form the lowest-cost supplier. Instead, it must now be promoted as an integral part of the technical and business case for a total lithographic solution. Improving partnership between designer, mask-maker, and wafer lithographer will be the harbinger of success in finding a profitable balance of capability, cost, and cycle time. Likewise for equipment infrastructure development, stronger partnership on the international level is necessary to control development cost and mitigate schedule and technical risks.

  20. Investigation of phase distribution using Phame® in-die phase measurements

    NASA Astrophysics Data System (ADS)

    Buttgereit, Ute; Perlitz, Sascha

    2009-03-01

    As lithography mask processes move toward 45nm and 32nm node, mask complexity increases steadily, mask specifications tighten and process control becomes extremely important. Driven by this fact the requirements for metrology tools increase as well. Efforts in metrology have been focused on accurately measuring CD linearity and uniformity across the mask, and accurately measuring phase variation on Alternating/Attenuated PSM and transmission for Attenuated PSM. CD control on photo masks is usually done through the following processes: exposure dose/focus change, resist develop and dry etch. The key requirement is to maintain correct CD linearity and uniformity across the mask. For PSM specifically, the effect of CD uniformity for both Alternating PSM and Attenuated PSM and etch depth for Alternating PSM becomes also important. So far phase measurement has been limited to either measuring large-feature phase using interferometer-based metrology tools or measuring etch depth using AFM and converting etch depth into phase under the assumption that trench profile and optical properties of the layers remain constant. However recent investigations show that the trench profile and optical property of layers impact the phase. This effect is getting larger for smaller CD's. The currently used phase measurement methods run into limitations because they are not able to capture 3D mask effects, diffraction limitations or polarization effects. The new phase metrology system - Phame(R) developed by Carl Zeiss SMS overcomes those limitations and enables laterally resolved phase measurement in any kind of production feature on the mask. The resolution of the system goes down to 120nm half pitch at mask level. We will report on tool performance data with respect to static and dynamic phase repeatability focusing on Alternating PSM. Furthermore the phase metrology system was used to investigate mask process signatures on Alternating PSM in order to further improve the overall PSM process performance. Especially global loading effects caused by the pattern density and micro loading effects caused by the feature size itself have been evaluated using the capability of measuring phase in the small production features. The results of this study will be reported in this paper.

  1. Contrast Gain Control Model Fits Masking Data

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Solomon, Joshua A.; Null, Cynthia H. (Technical Monitor)

    1994-01-01

    We studied the fit of a contrast gain control model to data of Foley (JOSA 1994), consisting of thresholds for a Gabor patch masked by gratings of various orientations, or by compounds of two orientations. Our general model includes models of Foley and Teo & Heeger (IEEE 1994). Our specific model used a bank of Gabor filters with octave bandwidths at 8 orientations. Excitatory and inhibitory nonlinearities were power functions with exponents of 2.4 and 2. Inhibitory pooling was broad in orientation, but narrow in spatial frequency and space. Minkowski pooling used an exponent of 4. All of the data for observer KMF were well fit by the model. We have developed a contrast gain control model that fits masking data. Unlike Foley's, our model accepts images as inputs. Unlike Teo & Heeger's, our model did not require multiple channels for different dynamic ranges.

  2. Etch bias inversion during EUV mask ARC etch

    NASA Astrophysics Data System (ADS)

    Lajn, Alexander; Rolff, Haiko; Wistrom, Richard

    2017-07-01

    The introduction of EUV lithography to high volume manufacturing is now within reach for 7nm technology node and beyond (1), at least for some steps. The scheduling is in transition from long to mid-term. Thus, all contributors need to focus their efforts on the production requirements. For the photo mask industry, these requirements include the control of defectivity, CD performance and lifetime of their masks. The mask CD performance including CD uniformity, CD targeting, and CD linearity/ resolution, is predominantly determined by the photo resist performance and by the litho and etch processes. State-of-the-art chemically amplified resists exhibit an asymmetric resolution for directly and indirectly written features, which usually results in a similarly asymmetric resolution performance on the mask. This resolution gap may reach as high as multiple tens of nanometers on the mask level in dependence of the chosen processes. Depending on the printing requirements of the wafer process, a reduction or even an increase of this gap may be required. A potential way of tuning via the etch process, is to control the lateral CD contribution during etch. Aside from process tuning knobs like pressure, RF powers and gases, which usually also affect CD linearity and CD uniformity, the simplest knob is the etch time itself. An increased over etch time results in an increased CD contribution in the normal case. , We found that the etch CD contribution of ARC layer etch on EUV photo masks is reduced by longer over etch times. Moreover, this effect can be demonstrated to be present for different etch chambers and photo resists.

  3. Clinical evaluation of endometriosis and differential response to surgical therapy with and without application of Oxiplex/AP* adhesion barrier gel.

    PubMed

    diZerega, Gere S; Coad, James; Donnez, Jacques

    2007-03-01

    To correlate parameters of endometriosis obtained during routine clinical evaluation with the subsequent formation of adhesions following surgical treatment by laparoscopy. Randomized, controlled, double-blind, clinical trial. Tertiary referral centers for the treatment of endometriosis. Thirty-seven patients (65 with adnexa) with stage I-III endometriosis; endometrioma-only patients were excluded. Laparoscopic surgical treatment of endometriosis, followed by randomization to Oxiplex/AP (FzioMed, Inc., San Luis Obispo, California) gel treatment (treated group) of adnexa, or surgery alone (control group); follow-up laparoscopy 6-10 weeks later. Adnexal Americn Fertility Society score, correlated with color and location of endometriosis, as well as stage of disease determined by masked review of videotapes. Control patients with at least 50% red lesions had a greater increase in ipsilateral adnexal adhesion scores than patients with mostly black or white and/or clear lesions. Treated patients with red lesions had a greater decrease in adnexal adhesion scores than control patients. There was a correlation between baseline endometriosis stage and postoperative adhesion formation in control patients, but not treated patients. Patients with red endometriotic lesions had greater increases in their adhesion scores than patients with only black, white, and/or clear lesions. Oxiplex/AP gel was effective in reducing adhesions, compared to surgery alone, in all groups.

  4. Rebamipide (OPC-12759) in the treatment of dry eye: a randomized, double-masked, multicenter, placebo-controlled phase II study.

    PubMed

    Kinoshita, Shigeru; Awamura, Saki; Oshiden, Kazuhide; Nakamichi, Norihiro; Suzuki, Hiroyuki; Yokoi, Norihiko

    2012-12-01

    To investigate the dose response for efficacy of 1% and 2% rebamipide ophthalmic suspension compared with placebo in patients with dry eye. A randomized, double-masked, multicenter, placebo-controlled, parallel-group, dose-response phase II study. A total of 308 patients with dry eye. After a 2-week screening period, patients were randomized to receive placebo or 1% rebamipide or 2% rebamipide administered as 1 drop in each eye 4 times daily for 4 weeks. The primary objective end point was change in fluorescein corneal staining (FCS) score from baseline to last observation carried forward (LOCF). Secondary objective end points were lissamine green conjunctival staining (LGCS) score, tear film break-up time (TBUT), and the Schirmer's test. Secondary subjective end points included dry eye-related ocular symptoms (foreign body sensation, dryness, photophobia, eye pain, and blurred vision) score and patients' overall treatment impression score. Rebamipide dose response was observed in FCS, LGCS, and TBUT scores. Both 1% and 2% rebamipide were significantly more effective than the placebo in terms of the change from baseline to LOCF for FCS, LGCS, and TBUT scores. There was no significant difference between the rebamipide and placebo groups from baseline to LOCF in Schirmer's test values, and dose response was not observed. In the predefined dry eye subpopulation with a baseline FCS score of 10 to 15, the mean change from baseline in the 2% rebamipide group was larger than that in the 1% rebamipide group. Change from baseline to LOCF for all 5 dry eye-related ocular symptom scores and patients' overall treatment impression showed significant improvements in the 1% and 2% rebamipide groups compared with the placebo group, except for photophobia in the 1% rebamipide group. No deaths or drug-related serious adverse events occurred in any treatment group. The incidence of ocular abnormalities was similar across the rebamipide and placebo groups. Rebamipide was effective in treating both objective signs and subjective symptoms of dry eye and were well tolerated in this 4-week study. Although 1% and 2% rebamipide were both efficacious, 2% rebamipide may be more effective than 1% rebamipide in some measures. Proprietary or commercial disclosure may be found after the references. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  5. Micronutrient Fortified Milk Improves Iron Status, Anemia and Growth among Children 1–4 Years: A Double Masked, Randomized, Controlled Trial

    PubMed Central

    Sazawal, Sunil; Dhingra, Usha; Dhingra, Pratibha; Hiremath, Girish; Sarkar, Archana; Dutta, Arup; Menon, Venugopal P.; Black, Robert E.

    2010-01-01

    Background Multiple micronutrient deficiencies are highly prevalent among preschool children and often lead to anemia and growth faltering. Given the limited success of supplementation and health education programs, fortification of foods could be a viable and sustainable option. We report results from a community based double-masked, randomized trial among children 1–4 years evaluating the effects of micronutrients (especially of zinc and iron) delivered through fortified milk on growth, anemia and iron status markers as part of a four group study design, running two studies simultaneously. Methods and Findings Enrolled children (n = 633) were randomly allocated to receive either micronutrients fortified milk (MN = 316) or control milk (Co = 317). Intervention of MN milk provided additional 7.8 mg zinc, 9.6 mg iron, 4.2 µg selenium, 0.27 mg copper, 156 µg vitamin A, 40.2 mg vitamin C, and 7.5 mg vitamin E per day (three serves) for one year. Anthropometry was recorded at baseline, mid- and end-study. Hematological parameters were estimated at baseline and end-study. Both groups were comparable at baseline. Compliance was over 85% and did not vary between groups. Compared to children consuming Co milk, children consuming MN milk showed significant improvement in weight gain (difference of mean: 0.21 kg/year; 95% confidence interval [CI] 0.12 to 0.31, p<0.001) and height gain (difference of mean: 0.51 cm/year; 95% CI 0.27 to 0.75, p<0.001). Mean hemoglobin (Hb) (difference of 13.6 g/L; 95% CI 11.1 to 16.0, p<0.001) and serum ferritin levels (difference of 7.9 µg/L; 95% CI 5.4 to 10.5, p<0.001) also improved. Children in MN group had 88% (odds ratio = 0.12, 95% CI 0.08 to 0.20, p<0.001) lower risk of iron deficiency anemia. Conclusions/Significance Milk provides an acceptable and effective vehicle for delivery of specific micronutrients, especially zinc and iron. Micronutrient bundle improved growth and iron status and reduced anemia in children 1–4 years old. Trial Registration ClinicalTrials.gov NCT00255385 PMID:20730057

  6. Attitudes of influenza‐vaccinated health care workers toward masks to prevent nosocomial transmission of influenza

    PubMed Central

    Brandt, Christian; Rabenau, Holger F.; Wicker, Sabine

    2010-01-01

    Please cite this paper as: Brandt et al. (2010) Attitudes of influenza‐vaccinated health care workers toward masks to prevent nosocomial transmission of influenza. . Influenza and Other Respiratory Viruses 5(1), 61–66. Background  Influenza viruses are highly contagious. Health care workers (HCWs) are at risk of occupational exposure to influenza and may transmit the infection to their patients and coworkers. Objectives  The aim of the study was to characterize the attitudes of HCWs regarding the use of surgical masks to prevent nosocomial influenza transmission. Furthermore, we assessed the informational needs of HCWs with regard to infection control measures. Methods  A survey was conducted among HCWs, using an anonymous questionnaire, at a German University Hospital during an influenza vaccination campaign. Results  Overall, 40·5% of the HCWs were vaccinated against seasonal influenza, and 35·2% were vaccinated against Influenza A/H1N1 (“swine flu”). In total, 1445 vaccinees completed the anonymous questionnaire. Of all respondents, 70·5% stated that the infection control recommendation “wearing a surgical” mask was appropriate to avoid influenza transmission. The percentage of HCWs who would like to have had more information about the infection control measures was 67·5%. Conclusions  Appropriate interventions ought to be taken to reduce the risk of exposure to influenza viruses among HCWs. Adherence to recommendations for the use of masks among HCWs needs to be evaluated. Further work is required to highlight the informational needs of HCWs to gain an appreciation of infection control measures. PMID:21138542

  7. Culture, gender and health care stigma: Practitioners' response to facial masking experienced by people with Parkinson's disease.

    PubMed

    Tickle-Degnen, Linda; Zebrowitz, Leslie A; Ma, Hui-ing

    2011-07-01

    Facial masking in Parkinson's disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners' responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners' impressions of patient psychological attributes. Practitioners (N = 284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners' judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners' judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners' use of facial expressivity in clinical impression formation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Culture, Gender and Health Care Stigma: Practitioners’ Response to Facial Masking Experienced by People with Parkinson’s Disease

    PubMed Central

    Tickle-Degnen, Linda; Zebrowitz, Leslie A.; Ma, Hui-ing

    2011-01-01

    Facial masking in Parkinson’s disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners’ responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners’ impressions of patient psychological attributes. Practitioners (N=284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners’ judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners’ judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners’ use of facial expressivity in clinical impression formation. PMID:21664737

  9. Deletion of Cytoplasmic Double-Stranded RNA Sensors Does Not Uncover Viral Small Interfering RNA Production in Human Cells.

    PubMed

    Schuster, Susan; Tholen, Lotte E; Overheul, Gijs J; van Kuppeveld, Frank J M; van Rij, Ronald P

    2017-01-01

    Antiviral immunity in insects and plants is mediated by the RNA interference (RNAi) pathway in which viral long double-stranded RNA (dsRNA) is processed into small interfering RNAs (siRNAs) by Dicer enzymes. Although this pathway is evolutionarily conserved, its involvement in antiviral defense in mammals is the subject of debate. In vertebrates, recognition of viral RNA induces a sophisticated type I interferon (IFN)-based immune response, and it has been proposed that this response masks or inhibits antiviral RNAi. To test this hypothesis, we analyzed viral small RNA production in differentiated cells deficient in the cytoplasmic RNA sensors RIG-I and MDA5. We did not detect 22-nucleotide (nt) viral siRNAs upon infection with three different positive-sense RNA viruses. Our data suggest that the depletion of cytoplasmic RIG-I-like sensors is not sufficient to uncover viral siRNAs in differentiated cells. IMPORTANCE The contribution of the RNA interference (RNAi) pathway in antiviral immunity in vertebrates has been widely debated. It has been proposed that RNAi possesses antiviral activity in mammalian systems but that its antiviral effect is masked by the potent antiviral interferon response in differentiated mammalian cells. In this study, we show that inactivation of the interferon response is not sufficient to uncover antiviral activity of RNAi in human epithelial cells infected with three wild-type positive-sense RNA viruses.

  10. Use of face masks by non-scrubbed operating room staff: a randomized controlled trial.

    PubMed

    Webster, Joan; Croger, Sarah; Lister, Carolyn; Doidge, Michelle; Terry, Michael J; Jones, Ian

    2010-03-01

    Ambiguity remains about the effectiveness of wearing surgical face masks. The purpose of this study was to assess the impact on surgical site infections (SSIs) when non-scrubbed operating room staff did not wear surgical face masks. Eight hundred twenty-seven participants undergoing elective or emergency obstetric, gynecological, general, orthopaedic, breast or urological surgery in an Australian tertiary hospital were enrolled. Complete follow-up data were available for 811 patients (98.1%). Operating room lists were randomly allocated to a 'Mask group' (all non-scrubbed staff wore a mask) or 'No Mask group' (none of the non-scrubbed staff wore masks). The primary end point, SSI was identified using in-patient surveillance; post discharge follow-up and chart reviews. The patient was followed for up to six weeks. Overall, 83 (10.2%) surgical site infections were recorded; 46/401 (11.5%) in the Masked group and 37/410 (9.0%) in the No Mask group; odds ratio (OR) 0.77 (95% confidence interval (CI) 0.49 to 1.21), p = 0.151. Independent risk factors for surgical site infection included: any pre-operative stay (adjusted odds ratio [aOR], 0.43 (95% CI, 0.20; 0.95), high BMI aOR, 0.38 (95% CI, 0.17; 0.87), and any previous surgical site infection aOR, 0.40 (95% CI, 0.17; 0.89). Surgical site infection rates did not increase when non-scrubbed operating room personnel did not wear a face mask.

  11. Increased masked hypertension prevalence in patients with obesity.

    PubMed

    Özkan, Selçuk; Ata, Naim; Yavuz, Bunyamin

    2018-02-08

    Masked hypertension is associated with an increased risk for cardiovascular conditions. The aim of the study was to evaluate the relationship obesity parameters, including body weight, waist circumference, and body mass index. The study group consisted of 251 consecutive outpatient subjects without overt hypertension. Subjects were classified according to BMI. After a complete medical history and laboratory examination, patients' height, weight, waist circumference heart rate, and office blood pressure were recorded. All subjects underwent ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of Masked hypertension was significantly higher in patients with obesity than controls (30.9% vs 5.7%, p < 0.001). Body mass index (33.2 ± 4.3 vs 25.1 ± 2.7 p < 0.001), waist circumference (98.5 ± 11.7 vs 86.8 ± 8.8, p < 0.001), and weight (86.5 ± 11.8 vs. 69 ± 9.1, p < 0.001) in patients with obesity were significantly higher than in patients with normal weight. Office Systolic BP (121.8 ± 4.4 vs 120.5 ± 4.78, p = 0.035), ambulatory daytime systolic BP (128.8 ± 8.9 vs 124.5 ± 7.4, p < 0.001), ambulatory daytime diastolic BP (73.9 ± 9.5 vs 71.5 ± 7.0, p = 0.019), ambulatory night-time systolic BP in patients with obesity was significantly higher than in patients with normal weight. This study demonstrated that masked hypertension prevalence is higher in patients with obesity than control patients. It can be suggested that predefining obesity might be helpful in early detection of masked hypertension.

  12. Masked and unmasked error-related potentials during continuous control and feedback

    NASA Astrophysics Data System (ADS)

    Lopes Dias, Catarina; Sburlea, Andreea I.; Müller-Putz, Gernot R.

    2018-06-01

    The detection of error-related potentials (ErrPs) in tasks with discrete feedback is well established in the brain–computer interface (BCI) field. However, the decoding of ErrPs in tasks with continuous feedback is still in its early stages. Objective. We developed a task in which subjects have continuous control of a cursor’s position by means of a joystick. The cursor’s position was shown to the participants in two different modalities of continuous feedback: normal and jittered. The jittered feedback was created to mimic the instability that could exist if participants controlled the trajectory directly with brain signals. Approach. This paper studies the electroencephalographic (EEG)—measurable signatures caused by a loss of control over the cursor’s trajectory, causing a target miss. Main results. In both feedback modalities, time-locked potentials revealed the typical frontal-central components of error-related potentials. Errors occurring during the jittered feedback (masked errors) were delayed in comparison to errors occurring during normal feedback (unmasked errors). Masked errors displayed lower peak amplitudes than unmasked errors. Time-locked classification analysis allowed a good distinction between correct and error classes (average Cohen-, average TPR  =  81.8% and average TNR  =  96.4%). Time-locked classification analysis between masked error and unmasked error classes revealed results at chance level (average Cohen-, average TPR  =  60.9% and average TNR  =  58.3%). Afterwards, we performed asynchronous detection of ErrPs, combining both masked and unmasked trials. The asynchronous detection of ErrPs in a simulated online scenario resulted in an average TNR of 84.0% and in an average TPR of 64.9%. Significance. The time-locked classification results suggest that the masked and unmasked errors were indistinguishable in terms of classification. The asynchronous classification results suggest that the feedback modality did not hinder the asynchronous detection of ErrPs.

  13. EUVL masks: paving the path for commercialization

    NASA Astrophysics Data System (ADS)

    Mangat, Pawitter J. S.; Hector, Scott D.

    2001-09-01

    Optical projection lithography has been the principal vehicle of semiconductor manufacturing for more than 20 years and is marching aggressively to satisfy the needs of semiconductor manufacturers for 100nm devices. However, the complexity of optical lithography continues to increase as wavelength reduction continues to 157nm. Extreme Ultraviolet Lithography (EUVL), with wavelength from 13-14 nm, is evolving as a leading next generation lithography option for semiconductor industry to stay on the path laid by Moore's Law. Masks are a critical part of the success of any technology and are considered to be high risk both for optical lithography and NGL technologies for sub-100nm lithography. Two key areas of EUV mask fabrication are reflective multilayer deposition and absorber patterning. In the case of reflective multilayers, delivering defect free multilayers for mask blanks is the biggest challenge. Defect mitigation is being explored as a possible option to smooth the multilayer defects in addition to optimization of the deposition process to reduce defect density. The mask patterning process needs focus on the defect-free absorber stack patterning process, mask cleaning, inspection and repair. In addition, there is considerable effort to understand by simulations, the defect printability, thermal and mechanical distortions, and non-telecentric illumination, to mention a few. To protect the finished mask from defects added during use, a removable pellicle strategy combined with thermophoretic protection during exposure is being developed. Recent migration to square form factor using low thermal expansion material (LTEM) is advantageous as historical developments in optical masks can be applied to EUV mask patterning. This paper addresses recent developments in the EUV mask patterning and highlights critical manufacturing process controls needed to fabricate defect-free full field masks with CD and image placement specifications for sub-70nm node lithography. No technology can be implemented without establishing the commercial infrastructure. The rising cost seems to be a major issue affecting the technology development. With respect to mask fabrication for commercial availability, a virtual mask shop analysis is presented that indicates that the process cost for EUVL masks are comparable to the high end optical mask with a reasonable yield. However, the cost for setting up a new mask facility is considerably high.

  14. Uniformity Masks Design Method Based on the Shadow Matrix for Coating Materials with Different Condensation Characteristics

    PubMed Central

    2013-01-01

    An intuitionistic method is proposed to design shadow masks to achieve thickness profile control for evaporation coating processes. The proposed method is based on the concept of the shadow matrix, which is a matrix that contains coefficients that build quantitive relations between shape parameters of masks and shadow quantities of substrate directly. By using the shadow matrix, shape parameters of shadow masks could be derived simply by solving a matrix equation. Verification experiments were performed on a special case where coating materials have different condensation characteristics. By using the designed mask pair with complementary shapes, thickness uniformities of better than 98% are demonstrated for MgF2 (m = 1) and LaF3 (m = 0.5) simultaneously on a 280 mm diameter spherical substrate with the radius curvature of 200 mm. PMID:24227996

  15. Behind the mask. Journey through an epidemic: some observations of contrasting public health responses to SARS

    PubMed Central

    Syed, Q; Sopwith, W; Regan, M; Bellis, M

    2003-01-01

    SARS has been called the first global epidemic of the 21st century and has been the cause of a massive and varied public health response in many countries of the world. This report describes observations made by two authors on a journey from Manchester in the United Kingdom to Chiang Mai in Thailand during the peak of global transmission. The public response to SARS, particularly characterised by the wearing of face masks, seemed to outstrip official guidance. Though of uncertain protective benefit, the wearing of masks may have contributed to the awareness of the collective and personal responsibility in combating infectious disease. Active and empowered involvement of the general public in implementing and cooperating with public health control measures supported by national and international authorities has clearly helped to bring SARS under control. The public health significance of such potent symbols as the face mask may be considered in strategies to tackle other emerging infections. PMID:14600109

  16. Controlling bridging and pinching with pixel-based mask for inverse lithography

    NASA Astrophysics Data System (ADS)

    Kobelkov, Sergey; Tritchkov, Alexander; Han, JiWan

    2016-03-01

    Inverse Lithography Technology (ILT) has become a viable computational lithography candidate in recent years as it can produce mask output that results in process latitude and CD control in the fab that is hard to match with conventional OPC/SRAF insertion approaches. An approach to solving the inverse lithography problem as a nonlinear, constrained minimization problem over a domain mask pixels was suggested in the paper by Y. Granik "Fast pixel-based mask optimization for inverse lithography" in 2006. The present paper extends this method to satisfy bridging and pinching constraints imposed on print contours. Namely, there are suggested objective functions expressing penalty for constraints violations, and their minimization with gradient descent methods is considered. This approach has been tested with an ILT-based Local Printability Enhancement (LPTM) tool in an automated flow to eliminate hotspots that can be present on the full chip after conventional SRAF placement/OPC and has been applied in 14nm, 10nm node production, single and multiple-patterning flows.

  17. Detection of visual events along the apparent motion trace in patients with paranoid schizophrenia.

    PubMed

    Sanders, Lia Lira Olivier; Muckli, Lars; de Millas, Walter; Lautenschlager, Marion; Heinz, Andreas; Kathmann, Norbert; Sterzer, Philipp

    2012-07-30

    Dysfunctional prediction in sensory processing has been suggested as a possible causal mechanism in the development of delusions in patients with schizophrenia. Previous studies in healthy subjects have shown that while the perception of apparent motion can mask visual events along the illusory motion trace, such motion masking is reduced when events are spatio-temporally compatible with the illusion, and, therefore, predictable. Here we tested the hypothesis that this specific detection advantage for predictable target stimuli on the apparent motion trace is reduced in patients with paranoid schizophrenia. Our data show that, although target detection along the illusory motion trace is generally impaired, both patients and healthy control participants detect predictable targets more often than unpredictable targets. Patients had a stronger motion masking effect when compared to controls. However, patients showed the same advantage in the detection of predictable targets as healthy control subjects. Our findings reveal stronger motion masking but intact prediction of visual events along the apparent motion trace in patients with paranoid schizophrenia and suggest that the sensory prediction mechanism underlying apparent motion is not impaired in paranoid schizophrenia. Copyright © 2012. Published by Elsevier Ireland Ltd.

  18. Acute Effects of Continuous Positive Air way Pressure on Pulse Pressure in Chronic Heart Failure

    PubMed Central

    Quintão, Mônica; Chermont, Sérgio; Marchese, Luana; Brandão, Lúcia; Bernardez, Sabrina Pereira; Mesquita, Evandro Tinoco; Rocha, Nazareth de Novaes; Nóbrega, Antônio Claudio L.

    2014-01-01

    Background Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. Objective The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Methods Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. Results CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min). Conclusion NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome. PMID:24676373

  19. In-line verification of linewidth uniformity for 0.18 and below: design rule reticles

    NASA Astrophysics Data System (ADS)

    Tan, TaiSheng; Kuo, Shen C.; Wu, Clare; Falah, Reuven; Hemar, Shirley; Sade, Amikam; Gottlib, Gidon

    2000-07-01

    Mask making process development and control is addressed using a reticle inspection tool equipped with the new revolutionized application called LBM-Linewidth Bias Monitoring. In order to use the LBM for mask-making process control, procedures and corresponding test plates are a developed, such that routine monitoring of the manufacturing process discloses process variation and machine variation. At the same time systematic variation are studied and either taken care of or taken into consideration to allow successful production line work. In this paper the contribution of the LBM for mask quality monitoring is studied with respect to dense layers, e.g. DRAM. Another aspect of this application - the detection of very small CD mis-uniformity areas is discussed.

  20. X-ray mask and method for making

    DOEpatents

    Morales, Alfredo M.

    2004-10-26

    The present invention describes a method for fabricating an x-ray mask tool which is a contact lithographic mask which can provide an x-ray exposure dose which is adjustable from point-to-point. The tool is useful in the preparation of LIGA plating molds made from PMMA, or similar materials. In particular the tool is useful for providing an ability to apply a graded, or "stepped" x-ray exposure dose across a photosensitive substrate. By controlling the x-ray radiation dose from point-to-point, it is possible to control the development process for removing exposed portions of the substrate; adjusting it such that each of these portions develops at a more or less uniformly rate regardless of feature size or feature density distribution.

  1. Exposure control practices for administering nitrous oxide: A survey of dentists, dental hygienists, and dental assistants.

    PubMed

    Boiano, James M; Steege, Andrea L; Sweeney, Marie H

    2017-06-01

    Engineering, administrative, and work practice controls have been recommended for many years to minimize exposure to nitrous oxide during dental procedures. To better understand the extent to which these exposure controls are used, the NIOSH Health and Safety Practices Survey of Healthcare Workers was conducted among members of professional practice organizations representing dentists, dental hygienists and dental assistants. The anonymous, modular, web-based survey was completed by 284 dental professionals in private practice who administered nitrous oxide to adult and/or pediatric patients in the seven days prior to the survey. Use of primary engineering controls (i.e., nasal scavenging mask and/or local exhaust ventilation (LEV) near the patient's mouth) was nearly universal, reported by 93% and 96% of respondents who administered to adult (A) and pediatric (P) patients, respectively. However, adherence to other recommended precautionary practices were lacking to varying degrees, and were essentially no different among those administering nitrous oxide to adult or pediatric patients. Examples of work practices which increase exposure risk, expressed as percent of respondents, included: not checking nitrous oxide equipment for leaks (41% A; 48% P); starting nitrous oxide gas flow before delivery mask or airway mask was applied to patient (13% A; 12% P); and not turning off nitrous oxide gas flow before turning off oxygen flow to the patient (8% A; 7% P). Absence of standard procedures to minimize worker exposure to nitrous oxide (13% of all respondents) and not being trained on safe handling and administration of nitrous oxide (3%) were examples of breaches of administrative controls which may also increase exposure risk. Successful management of nitrous oxide emissions should include properly fitted nasal scavenging masks, supplemental LEV (when nitrous oxide levels cannot be adequately controlled using nasal masks alone), adequate general ventilation, regular inspection of nitrous oxide delivery and scavenging equipment for leaks, availability of standard procedures to minimize exposure, periodic training, ambient air and exposure monitoring, and medical surveillance.

  2. Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak.

    PubMed

    Bakker, Jessie P; Neill, Alister M; Campbell, Angela J

    2012-09-01

    This single-blinded, randomized, controlled pilot study aimed to investigate whether there is a difference between nasal and oronasal masks in therapeutic continuous positive airway pressure (CPAP) requirement, residual disease, or leak when treating obstructive sleep apnea (OSA) and if differences were related to measures of upper airway size. Patients with severe OSA currently using CPAP at ≥4 h/night with a nasal mask were examined (including Mallampati scale, incisal relationship, and mandibular protrusion) and then randomized to receive auto-positive airway pressure (PAP) or fixed CPAP at a manually titrated pressure for 1 week each at home, with immediate crossover. Within each week, a nasal mask and two oronasal masks were to be used for two or three nights each in random order. Data were downloaded from the device. Twelve patients completed the trial (mean ± SD AHI 59.8 ± 28.6 events/h; CPAP 11.1 ± 3.2 cmH(2)O; BMI 37.7 ± 5.0 kg/m(2)). During auto-PAP, the median 95th percentile pressure delivered with all masks was within 0.5 cmH(2)O (p > 0.05). During CPAP, median residual AHI was 0.61 (IQR = 1.18) for the nasal mask, 1.70 (IQR = 4.04) for oronasal mask 1, and 2.48 (IQR = 3.74) for oronasal mask 2 (p = 0.03). The 95th percentile leak was lowest with the nasal mask during both CPAP and auto-PAP (both p < 0.01). Differences in pressure or residual disease were not related to measures of upper airway shape or body habitus. In obese OSA patients changing from a nasal to oronasal mask increased leak and residual AHI but did not affect the therapeutic pressure requirement. The findings of the current study highlight mask leak as the major difficulty in the use of oronasal masks.

  3. Marine Mammals: Hearing and Echolocation at Coconut Island

    DTIC Science & Technology

    2009-09-30

    113(5), 2408-2411 5 Supin, A. Ya., Nachtigall, P.E., and Breese, M. (2009) Forward masking based gain control in odontocete biosonar : an evoked...odontocete biosonar : an evoked-potential study. J Acous Soc Am (published, refereed) Mooney T.A., Nachtigall, P.E. Breese, M. Vlachos, S. and...Nachtigall, P.E. and Breese, M. (2008) Forward masking as a mechanism of automatic gain control in whale biosonar : a psychophysical study, Journal of the

  4. N7 logic via patterning using templated DSA: implementation aspects

    NASA Astrophysics Data System (ADS)

    Bekaert, J.; Doise, J.; Gronheid, R.; Ryckaert, J.; Vandenberghe, G.; Fenger, G.; Her, Y. J.; Cao, Y.

    2015-07-01

    In recent years, major advancements have been made in the directed self-assembly (DSA) of block copolymers (BCP). Insertion of DSA for IC fabrication is seriously considered for the 7 nm node. At this node the DSA technology could alleviate costs for multiple patterning and limit the number of masks that would be required per layer. At imec, multiple approaches for inserting DSA into the 7 nm node are considered. One of the most straightforward approaches for implementation would be for via patterning through templated DSA; a grapho-epitaxy flow using cylindrical phase BCP material resulting in contact hole multiplication within a litho-defined pre-pattern. To be implemented for 7 nm node via patterning, not only the appropriate process flow needs to be available, but also DSA-aware mask decomposition is required. In this paper, several aspects of the imec approach for implementing templated DSA will be discussed, including experimental demonstration of density effect mitigation, DSA hole pattern transfer and double DSA patterning, creation of a compact DSA model. Using an actual 7 nm node logic layout, we derive DSA-friendly design rules in a logical way from a lithographer's view point. A concrete assessment is provided on how DSA-friendly design could potentially reduce the number of Via masks for a place-and-routed N7 logic pattern.

  5. Nanofabrication of 10-nm T-shaped gates using a double patterning process with electron beam lithography and dry etch

    NASA Astrophysics Data System (ADS)

    Shao, Jinhai; Deng, Jianan; Lu, W.; Chen, Yifang

    2017-07-01

    A process to fabricate T-shaped gates with the footprint scaling down to 10 nm using a double patterning procedure is reported. One of the keys in this process is to separate the definition of the footprint from that for the gate-head so that the proximity effect originated from electron forward scattering in the resist is significantly minimized, enabling us to achieve as narrow as 10-nm foot width. Furthermore, in contrast to the reported technique for 10-nm T-shaped profile in resist, this process utilizes a metallic film with a nanoslit as an etch mask to form a well-defined 10-nm-wide foot in a SiNx layer by reactive ion etch. Such a double patterning process has demonstrated enhanced reliability. The detailed process is comprehensively described, and its advantages and limitations are discussed. Nanofabrication of InP-based high-electron-mobility transistors using the developed process for 10- to 20-nm T-shaped gates is currently under the way.

  6. Flexible organic light-emitting diodes with enhanced light out-coupling efficiency fabricated on a double-sided nanotextured substrate.

    PubMed

    Luo, Yu; Wang, Chunhui; Wang, Li; Ding, Yucheng; Li, Long; Wei, Bin; Zhang, Jianhua

    2014-07-09

    High-efficiency organic light-emitting diodes (OLEDs) have generated tremendous research interest. One of the exciting possibilities of OLEDs is the use of flexible plastic substrates, which unfortunately have a mismatching refractive index compared with the conventional ITO anode and the air. To unlock the light loss on flexible plastic, we report a high-efficiency flexible OLED directly fabricated on a double-sided nanotextured polycarbonate substrate by thermal nanoimprint lithography. The template for the nanoimprint process is a replicate from a silica arrayed with nanopillars and fabricated by ICP etching through a SiO2 colloidal spheres mask. It has been shown that with the internal quasi-periodical scattering gratings the efficiency enhancement can reach 50% for a green light OLED, and with an external antireflection structure, the normal transmittance is increased from 89% to 94% for paraboloid-like pillars. The OLED directly fabricated on the double-sided nanotextured polycarbonate substrate has reached an enhancing factor of ∼2.8 for the current efficiency.

  7. Detection of DNA double-strand breaks and chromosome translocations using ligation-mediated PCR and inverse PCR.

    PubMed

    Villalobos, Michael J; Betti, Christopher J; Vaughan, Andrew T M

    2006-01-01

    Current techniques for examining the global creation and repair of DNA double-strand breaks are restricted in their sensitivity, and such techniques mask any site-dependent variations in breakage and repair rate or fidelity. We present here a system for analyzing the fate of documented DNA breaks, using the MLL gene as an example, through application of ligation-mediated PCR. Here, a simple asymmetric double-stranded DNA adapter molecule is ligated to experimentally induced DNA breaks and subjected to seminested PCR using adapter and gene-specific primers. The rate of appearance and loss of specific PCR products allows detection of both the break and its repair. Using the additional technique of inverse PCR, the presence of misrepaired products (translocations) can be detected at the same site, providing information on the fidelity of the ligation reaction in intact cells. Such techniques may be adapted for the analysis of DNA breaks introduced into any identifiable genomic location.

  8. Antibiotic resistance patterns in fecal bacteria isolated from Christmas shearwater (Puffinus nativitatis) and masked booby (Sula dactylatra) at remote Easter Island.

    PubMed

    Ardiles-Villegas, Karen; González-Acuña, Daniel; Waldenström, Jonas; Olsen, Björn; Hernández, Jorge

    2011-09-01

    Antibiotic use and its implications have been discussed extensively in the past decades. This situation has global consequences when antibiotic resistance becomes widespread in the intestinal bacterial flora of stationary and migratory birds. This study investigated the incidence of fecal bacteria and general antibiotic resistance, with special focus on extended spectrum beta-lactamase (ESBL) isolates, in two species of seabirds at remote Easter Island. We identified 11 species of bacteria from masked booby (Sula dactylatra) and Christmas shearwater (Puffinus nativitatis); five species of gram-negative bacilli, four species of Streptococcus (Enterococcus), and 2 species of Staphylococcus. In addition, 6 types of bacteria were determined barely to the genus level. General antibiotic susceptibility was measured in the 30 isolated Enterobacteriaceae to 11 antibiotics used in human and veterinary medicine. The 10 isolates that showed a phenotypic ESBL profile were verified by clavulanic acid inhibition in double mixture discs with cefpodoxime, and two ESBL strains were found, one strain in masked booby and one strain in Christmas shearwater. The two bacteria harboring the ESBL type were identified as Serratia odorifera biotype 1, which has zoonotic importance. Despite minimal human presence in the masked booby and Christmas shearwater habitats, and the extreme geographic isolation of Easter Island, we found several multiresistant bacteria and even two isolates with ESBL phenotypes. The finding of ESBLs has animal and public health significance and is of potential concern, especially because the investigation was limited in size and indicated that antibiotic-resistant bacteria now are distributed globally.

  9. Generic hierarchical engine for mask data preparation

    NASA Astrophysics Data System (ADS)

    Kalus, Christian K.; Roessl, Wolfgang; Schnitker, Uwe; Simecek, Michal

    2002-07-01

    Electronic layouts are usually flattened on their path from the hierarchical source downstream to the wafer. Mask data preparation has certainly been identified as a severe bottleneck since long. Data volumes are not only doubling every year along the ITRS roadmap. With the advent of optical proximity correction and phase-shifting masks data volumes are escalating up to non-manageable heights. Hierarchical treatment is one of the most powerful means to keep memory and CPU consumption in reasonable ranges. Only recently, however, has this technique acquired more public attention. Mask data preparation is the most critical area calling for a sound infrastructure to reduce the handling problem. Gaining more and more attention though, are other applications such as large area simulation and manufacturing rule checking (MRC). They all would profit from a generic engine capable to efficiently treat hierarchical data. In this paper we will present a generic engine for hierarchical treatment which solves the major problem, steady transitions along cell borders. Several alternatives exist how to walk through the hierarchy tree. They have, to date, not been thoroughly investigated. One is a bottom-up attempt to treat cells starting with the most elementary cells. The other one is a top-down approach which lends itself to creating a new hierarchy tree. In addition, since the variety, degree of hierarchy and quality of layouts extends over a wide range a generic engine has to take intelligent decisions when exploding the hierarchy tree. Several applications will be shown, in particular how far the limits can be pushed with the current hierarchical engine.

  10. Current status of x-ray mask manufacturing at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-07-01

    The Microlithographic Mask Development Center (MMD) has been the focal point of X-ray mask development efforts in the United States since its inception in 1993. Funded by the Advanced Research Projects Agency (ARPA), and with technical support from the Proximity X-ray Lithography Association (AT&T, IBM, Loral Federal Systems, and Motorola) the MMD has recently made dramatic advances in mask fabrication. Numerous defect-free 64Mb and 256Mb DRAM masks have been made on both boron-doped silicon and silicon carbide substrates. Image-placement error of less than 35nm 3 sigma is achieved with high yield. Image-size (critical dimension) control of 25nm 3 sigma on 250nm nominal images is representative performance. This progress is being made in a manufacturing environment with significant volumes, multiple customers, multiple substrate configurations, and fast turnaround-time (TAT) requirements. The MMD state-of-the-art equipment infrastructure has made much of this progress possible. This year the MMD qualified the EL-4, an IBM-designed-and-built variable-shaped-spot e-beam system. The fundamental performance parameters of this system will be described. Operational techniques of multiple partial exposure writing and product specific emulation (PSE) have been implemented to improve image-placement accuracy with remarkable success. Image-size control was studied in detail with contributory components separated. Defect density was systematically reduced to yield defect-free masks while simultaneously tightening inspection criteria. Information about these and other recent engineering highlights will be reported. An outline of the primary engineering challenges and goals for 1996 and status of progress toward 100 nm design rule capability will also be given.

  11. Demonstration of Current Profile Shaping using Double Dog-Leg Emittance Exchange Beam Line at Argonne Wakefield Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ha, Gwanghui; Cho, Moo-Hyun; Conde, Manoel

    Emittance exchange (EEX) based longitudinal current profile shaping is the one of the promising current profile shaping technique. This method can generate high quality arbitrary current profiles under the ideal conditions. The double dog-leg EEX beam line was recently installed at the Argonne Wakefield Accelerator (AWA) to explore the shaping capability and confirm the quality of this method. To demonstrate the arbitrary current profile generation, several different transverse masks are applied to generate different final current profiles. The phase space slopes and the charge of incoming beam are varied to observe and suppress the aberrations on the ideal profile. Wemore » present current profile shaping results, aberrations on the shaped profile, and its suppression.« less

  12. Masking of a circadian behavior in larval zebrafish involves the thalamo-habenula pathway.

    PubMed

    Lin, Qian; Jesuthasan, Suresh

    2017-06-22

    Changes in illumination can rapidly influence behavior that is normally controlled by the circadian clock. This effect is termed masking. In mice, masking requires melanopsin-expressing retinal ganglion cells that detect blue light and project to the thalamus. It is not known whether masking is wavelength-dependent in other vertebrates, nor is it known whether the thalamus is also involved or how it influences masking. Here, we address these questions in zebrafish. We find that diel vertical migration, a circadian behavior in larval zebrafish, is effectively triggered by blue, but not by red light. Two-photon calcium imaging reveals that a thalamic nucleus and a downstream structure, the habenula, have a sustained response to blue but not to red light. Lesioning the habenula reduces light-evoked climbing. These data suggest that the thalamo-habenula pathway is involved in the ability of blue light to influence a circadian behavior.

  13. Mask-Assisted Seeded Growth of Segmented Metallic Heteronanostructures

    DOE PAGES

    Crane, Cameron C.; Tao, Jing; Wang, Feng; ...

    2014-12-04

    Controlling the deposition of exotic metals in the seeded growth of multi-metal nanostructures is challenging. This work describes a seeded growth method assisted by a mask for synthesis of segmented binary or ternary metal nanostructures. Silica is used as a mask to partially block the surface of a seed and a second metal is subsequently deposited on the exposed area, forming a bimetallic heterodimer. The initial demonstration was carried out on a Au seed, followed by deposition of Pd or Pt on the seed. It was found that Pd tends to spread out laterally on the seed while Pt inclinesmore » to grow vertically into branched topology on Au. Without removal of the SiO₂ mask, Pt could be further deposited on the unblocked Pd of the Pd-Au dimer to form a Pt-Pd-Au trimer. The mask-assisted seeded growth provides a general strategy to construct segmented metallic nanoarchitectures.« less

  14. Photorefractive keratectomy (PRK) at 193 nm using an erodible mask: new developments and clinical progress

    NASA Astrophysics Data System (ADS)

    Gordon, Michael; Seiler, Theo; Carey, Joseph P.; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.

    1993-06-01

    This paper reports on our progress using an erodible mask to perform photorefractive keratectomy (PRK) for the correction of myopic astigmatism. We describe modifications to the mask, the mask eye cup and the surgical microscope aimed at simplifying the procedure and improving the ergonomics of the hardware. We report the clinical results of the post-op exam for 20 patients who have undergone PRK for myopic astigmatism under a Phase IIA study. The results compare favorably with an earlier Phase IIA study for performing PRK with a computer-controlled iris. Most important, the clinical data show the absence of any significant corneal haze and no significant decrease in spectacle corrected visual acuity. Although more long term follow-up is needed, the preliminary results support the safety and effectiveness of using an erodible mask to perform PRK for myopic astigmatism.

  15. 6-month versus 36-month isoniazid preventive treatment for tuberculosis in adults with HIV infection in Botswana: a randomised, double-blind, placebo-controlled trial.

    PubMed

    Samandari, Taraz; Agizew, Tefera B; Nyirenda, Samba; Tedla, Zegabriel; Sibanda, Thabisa; Shang, Nong; Mosimaneotsile, Barudi; Motsamai, Oaitse I; Bozeman, Lorna; Davis, Margarett K; Talbot, Elizabeth A; Moeti, Themba L; Moffat, Howard J; Kilmarx, Peter H; Castro, Kenneth G; Wells, Charles D

    2011-05-07

    In accordance with WHO guidelines, people with HIV infection in Botswana receive daily isoniazid preventive therapy against tuberculosis without obtaining a tuberculin skin test, but duration of prophylaxis is restricted to 6 months. We aimed to assess effectiveness of extended isoniazid therapy. In our randomised, double-blind, placebo-controlled trial we enrolled adults infected with HIV aged 18 years or older at government HIV-care clinics in Botswana. Exclusion criteria included current illness such as cough and an abnormal chest radiograph without antecedent tuberculosis or pneumonia. Eligible individuals were randomly allocated (1:1) to receive 6 months' open-label isoniazid followed by 30 months' masked placebo (control group) or 6 months' open-label isoniazid followed by 30 months' masked isoniazid (continued isoniazid group) on the basis of a computer-generated randomisation list with permuted blocks of ten at each clinic. Antiretroviral therapy was provided if participants had CD4-positive lymphocyte counts of fewer than 200 cells per μL. We used Cox regression analysis and the log-rank test to compare incident tuberculosis in the groups. Cox regression models were used to estimate the effect of antiretroviral therapy. The trial is registered at ClinicalTrials.gov, number NCT00164281. Between Nov 26, 2004, and July 3, 2009, we recorded 34 (3·4%) cases of incident tuberculosis in 989 participants allocated to the control group and 20 (2·0%) in 1006 allocated to the continued isoniazid group (incidence 1·26% per year vs 0·72%; hazard ratio 0·57, 95% CI 0·33-0·99, p=0·047). Tuberculosis incidence in those individuals receiving placebo escalated approximately 200 days after completion of open-label isoniazid. Participants who were tuberculin skin test positive (ie, ≥5 mm induration) at enrolment received a substantial benefit from continued isoniazid treatment (0·26, 0·09-0·80, p=0·02), whereas participants who were tuberculin skin test-negative received no significant benefit (0·75, 0·38-1·46, p=0·40). By study completion, 946 (47%) of 1995 participants had initiated antiretroviral therapy. Tuberculosis incidence was reduced by 50% in those receiving 360 days of antiretroviral therapy compared with participants receiving no antiretroviral therapy (adjusted hazard ratio 0·50, 95% CI 0·26-0·97). Severe adverse events and death were much the same in the control and continued isoniazid groups. In a tuberculosis-endemic setting, 36 months' isoniazid prophylaxis was more effective for prevention of tuberculosis than was 6-month prophylaxis in individuals with HIV infection, and chiefly benefited those who were tuberculin skin test positive. US Centers for Disease Control and Prevention and US Agency for International Development. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Hyper-realistic face masks: a new challenge in person identification.

    PubMed

    Sanders, Jet Gabrielle; Ueda, Yoshiyuki; Minemoto, Kazusa; Noyes, Eilidh; Yoshikawa, Sakiko; Jenkins, Rob

    2017-01-01

    We often identify people using face images. This is true in occupational settings such as passport control as well as in everyday social environments. Mapping between images and identities assumes that facial appearance is stable within certain bounds. For example, a person's apparent age, gender and ethnicity change slowly, if at all. It also assumes that deliberate changes beyond these bounds (i.e., disguises) would be easy to spot. Hyper-realistic face masks overturn these assumptions by allowing the wearer to look like an entirely different person. If unnoticed, these masks break the link between facial appearance and personal identity, with clear implications for applied face recognition. However, to date, no one has assessed the realism of these masks, or specified conditions under which they may be accepted as real faces. Herein, we examined incidental detection of unexpected but attended hyper-realistic masks in both photographic and live presentations. Experiment 1 (UK; n = 60) revealed no evidence for overt detection of hyper-realistic masks among real face photos, and little evidence of covert detection. Experiment 2 (Japan; n = 60) extended these findings to different masks, mask-wearers and participant pools. In Experiment 3 (UK and Japan; n = 407), passers-by failed to notice that a live confederate was wearing a hyper-realistic mask and showed limited evidence of covert detection, even at close viewing distance (5 vs. 20 m). Across all of these studies, viewers accepted hyper-realistic masks as real faces. Specific countermeasures will be required if detection rates are to be improved.

  17. Taming the Wildness of "Trojan-Horse" Peptides by Charge-Guided Masking and Protease-Triggered Demasking for the Controlled Delivery of Antitumor Agents.

    PubMed

    Shi, Nian-Qiu; Qi, Xian-Rong

    2017-03-29

    Cell-penetrating peptide (CPP), also called "Trojan Horse" peptide, has become a successful approach to deliver various payloads into cells for achieving the intracellular access. However, the "Trojan Horse" peptide is too wild, not just to "Troy", but rather widely distributed in the body. Thus, there is an urgent need to tame the wildness of "Trojan Horse" peptide for targeted delivery of antineoplastic agents to the tumor site. To achieve this goal, we exploit a masked CPP-doxorubicin conjugate platform for targeted delivery of chemotherapeutic drugs using charge-guided masking and protease-triggered demasking strategies. In this platform, the cell-penetrating function of the positively CPP (d-form nonaarginine) is abrogated by a negatively shielding peptide (masked CPP), and between them is a cleavable substrate peptide by the protease (MMP-2/9). Protease-triggered demasking would occur when the masked CPP reached the MMP-2/9-riched tumor. The CPP-doxorubicin conjugate (CPP-Dox) and the masked CPP-Dox conjugate (mCPP-Dox) were used as models for the evaluation of masking and demasking processes. It was found that exogenous MMP-2/9 could effectively trigger the reversion of CPP-cargo in this conjugate, and this trigger adhered to the Michaelis-Menten kinetics profile. This conjugate was sensitive to the trigger of endogenous MMP-2/9 and could induce enhanced cytotoxicity toward MMP-2/9-rich tumor cells. In vivo antitumor efficacy revealed that this masked conjugate had considerable antitumor activity and could inhibit the tumor growth at a higher level relative to CPP-cargo. Low toxicity in vivo showed the noticeably decreased wildness of this conjugate toward normal tissues and more controllable entry of antitumor agents into "Troy". On the basis of analyses in vitro and in vivo, this mCPP-cargo conjugate delivery system held an improved selectivity toward MMP-2/9-rich tumors and would be a promising strategy for tumor-targeted treatment.

  18. STS-26 Pilot Covey, wearing sleep mask, rests on aft flight deck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Pilot Richard O. Covey, wearing sleep mask (blindfold) and a headset, props his feet under the pilots seat and rests his head and back on the aft flight deck onorbit station panels while he sleeps. At Covey's right are the mission station control panels.

  19. Arrays of quasi-hexagonally ordered silica nanopillars with independently controlled areal density, diameter and height gradients

    NASA Astrophysics Data System (ADS)

    Özdemir, Burcin; Huang, Wenting; Plettl, Alfred; Ziemann, Paul

    2015-03-01

    A consecutive fabrication approach of independently tailored gradients of the topographical parameters distance, diameter and height in arrays of well-ordered nanopillars on smooth SiO2-Si-wafers is presented. For this purpose, previously reported preparation techniques are further developed and combined. First, self-assembly of Au-salt loaded micelles by dip-coating with computer-controlled pulling-out velocities and subsequent hydrogen plasma treatment produce quasi-hexagonally ordered, 2-dimensional arrays of Au nanoparticles (NPs) with unidirectional variations of the interparticle distances along the pulling direction between 50-120 nm. Second, the distance (or areal density) gradient profile received in this way is superimposed with a diameter-controlled gradient profile of the NPs applying a selective photochemical growth technique. For demonstration, a 1D shutter is used for locally defined UV exposure times to prepare Au NP size gradients varying between 12 and 30 nm. Third, these double-gradient NP arrangements serve as etching masks in a following reactive ion etching step delivering arrays of nanopillars. For height gradient generation, the etching time is locally controlled by applying a shutter made from Si wafer piece. Due to the high flexibility of the etching process, the preparation route works on various materials such as cover slips, silicon, silicon oxide, silicon nitride and silicon carbide.

  20. Significance of auditory and kinesthetic feedback to singers' pitch control.

    PubMed

    Mürbe, Dirk; Pabst, Friedemann; Hofmann, Gert; Sundberg, Johan

    2002-03-01

    An accurate control of fundamental frequency (F0) is required from singers. This control relies on auditory and kinesthetic feedback. However, a loud accompaniment may mask the auditory feedback, leaving the singers to rely on kinesthetic feedback. The object of the present study was to estimate the significance of auditory and kinesthetic feedback to pitch control in 28 students beginning a professional solo singing education. The singers sang an ascending and descending triad pattern covering their entire pitch range with and without masking noise in legato and staccato and in a slow and a fast tempo. F0 was measured by means of a computer program. The interval sizes between adjacent tones were determined and their departures from equally tempered tuning were calculated. The deviations from this tuning were used as a measure of the accuracy of intonation. Statistical analysis showed a significant effect of masking that amounted to a mean impairment of pitch accuracy by 14 cent across all subjects. Furthermore, significant effects were found of tempo as well as of the staccato/legato conditions. The results indicate that auditory feedback contributes significantly to singers' control of pitch.

  1. Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.

    PubMed

    Napolitano, Natalie; Nishisaki, Akira; Buffman, Hayley S; Leffelman, Jessica; Maltese, Matthew R; Nadkarni, Vinay M

    2017-01-01

    Partial pressure of end-tidal carbon dioxide (P ETCO 2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring P ETCO 2 in children without a tracheal tube is challenging. To improve P ETCO 2 measurement accuracy in a commercially available mask with a mainstream CO 2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. Two sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO 2 . Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured. Bench testing revealed a P ETCO 2 difference of 3.4 ± 1.5 mm Hg between a measured P ETCO 2 by the redesigned mask and CO 2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between P ETCO 2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73). P ETCO 2 measurement by a redesigned open-system face mask with a mainstream CO 2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children. Copyright © 2017 by Daedalus Enterprises.

  2. Masked priming effects are modulated by expertise in the script.

    PubMed

    Perea, Manuel; Abu Mallouh, Reem; Garcı A-Orza, Javier; Carreiras, Manuel

    2011-05-01

    In a recent study using a masked priming same-different matching task, Garcı´a-Orza, Perea, and Munoz (2010) found a transposition priming effect for letter strings, digit strings, and symbol strings, but not for strings of pseudoletters (i.e., EPRI-ERPI produced similar response times to the control pair EDBI-ERPI). They argued that the mechanism responsible for position coding in masked priming is not operative with those "objects" whose identity cannot be attained rapidly. To assess this hypothesis, Experiment 1 examined masked priming effects in Arabic for native speakers of Arabic, whereas participants in Experiments 2 and 3 were lower intermediate learners of Arabic and readers with no knowledge of Arabic, respectively. Results showed a masked priming effect only for readers who are familiar with the Arabic script. Furthermore, transposed-letter priming in native speakers of Arabic only occurred when the order of the root letters was kept intact. In Experiments 3-7, we examined why masked repetition priming is absent for readers who are unfamiliar with the Arabic script. We discuss the implications of these findings for models of visual-word recognition.

  3. Dry etching technologies for reflective multilayer

    NASA Astrophysics Data System (ADS)

    Iino, Yoshinori; Karyu, Makoto; Ita, Hirotsugu; Kase, Yoshihisa; Yoshimori, Tomoaki; Muto, Makoto; Nonaka, Mikio; Iwami, Munenori

    2012-11-01

    We have developed a highly integrated methodology for patterning Extreme Ultraviolet (EUV) mask, which has been highlighted for the lithography technique at the 14nm half-pitch generation and beyond. The EUV mask is characterized as a reflective-type mask which is completely different compared with conventional transparent-type of photo mask. And it requires not only patterning of absorber layer without damaging the underlying multi reflective layers (40 Si/Mo layers) but also etching multi reflective layers. In this case, the dry etch process has generally faced technical challenges such as the difficulties in CD control, etch damage to quartz substrate and low selectivity to the mask resist. Shibaura Mechatronics ARESTM mask etch system and its optimized etch process has already achieved the maximal etch performance at patterning two-layered absorber. And in this study, our process technologies of multi reflective layers will be evaluated by means of optimal combination of process gases and our optimized plasma produced by certain source power and bias power. When our ARES™ is used for multilayer etching, the user can choose to etch the absorber layer at the same time or etch only the multilayer.

  4. Practices around the use of masks and respirators among hospital health care workers in 3 diverse populations.

    PubMed

    Chughtai, Abrar Ahmad; MacIntyre, C Raina; Ashraf, Muhammad Orooj; Zheng, Yang; Yang, Peng; Wang, Quanyi; Dung, Tham Chi; Hien, Nguyen Tran; Seale, Holly

    2015-10-01

    A cross-sectional survey was conducted in 89 secondary- and tertiary-level hospitals in 3 countries, and samples of masks and respirators were also collected and examined. Results showed varied practices around the use of masks and respirators, which are probably influenced by the available resources and local recommendations. Nonstandardized practices are common in low-resource settings, which may be placing health care workers at risk. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. The complete mitochondrial genome of the masked palm civet (Paguma larvata, Mammalia, Carnivora).

    PubMed

    Zhang, Dan; Xu, Liwen; Bu, Hongliang; Wang, Di; Xu, Chongren; Wang, Rongjiang

    2016-09-01

    The complete mitochondrial genome of the masked palm civet (Paguma larvata, Mammalia, Carnivora) is a circular molecule of 16 710 bp in length, containing 22 transfer RNA genes, 13 protein-coding genes, two ribosomal RNA genes, and a control region. The features of the mitochondrial genome of the masked palm civet are similar to the other mammals. The phylogenetic analysis shows that all species from the family Viverridae cluster together, in which P. larvata exhibits the closest relationship with Genetta servalina.

  6. Masking as an effective quality control method for next-generation sequencing data analysis.

    PubMed

    Yun, Sajung; Yun, Sijung

    2014-12-13

    Next generation sequencing produces base calls with low quality scores that can affect the accuracy of identifying simple nucleotide variation calls, including single nucleotide polymorphisms and small insertions and deletions. Here we compare the effectiveness of two data preprocessing methods, masking and trimming, and the accuracy of simple nucleotide variation calls on whole-genome sequence data from Caenorhabditis elegans. Masking substitutes low quality base calls with 'N's (undetermined bases), whereas trimming removes low quality bases that results in a shorter read lengths. We demonstrate that masking is more effective than trimming in reducing the false-positive rate in single nucleotide polymorphism (SNP) calling. However, both of the preprocessing methods did not affect the false-negative rate in SNP calling with statistical significance compared to the data analysis without preprocessing. False-positive rate and false-negative rate for small insertions and deletions did not show differences between masking and trimming. We recommend masking over trimming as a more effective preprocessing method for next generation sequencing data analysis since masking reduces the false-positive rate in SNP calling without sacrificing the false-negative rate although trimming is more commonly used currently in the field. The perl script for masking is available at http://code.google.com/p/subn/. The sequencing data used in the study were deposited in the Sequence Read Archive (SRX450968 and SRX451773).

  7. A randomized double-masked study to compare the ocular safety, tolerability, and efficacy of bromfenac 0.075% compared with vehicle in cataract surgery subjects

    PubMed Central

    Hosseini, Kamran; Walters, Thomas; DaVanzo, Robert; Lindstrom, Richard L

    2016-01-01

    Purpose The aim of this study was to evaluate the safety, tolerability, and efficacy of a low-dose version of bromfenac 0.075% in DuraSite® (bromfenac 0.075%) compared with DuraSite® vehicle (vehicle) alone for the treatment of postoperative inflammation and ocular pain after cataract surgery. Methods A multicenter, double-masked, vehicle-controlled, parallel-group clinical trial of 240 subjects randomized in a 2:1 ratio to bromfenac 0.075% or vehicle was conducted. Subjects were dosed BID beginning 1 day before the cataract surgery, the day of surgery, and 14 days after surgery. A slit lamp biomicroscopy examination was performed to evaluate the signs of inflammation, including anterior chamber cells (ACC) and anterior chamber flare (ACF). The primary efficacy variable was the proportion of subjects with an ACC grade of 0 at Day 15. Secondary efficacy endpoints included the proportion of subjects who achieved a pain score of 0 at each postsurgical visual analog scale (VAS) assessment and the proportion of subjects with an ACF grade of 0 at Day 15. Results At Day 15, proportionally more subjects in the bromfenac 0.075% group than in the vehicle group had an ACC grade of 0 (57.1% vs 18.8%, respectively; P<0.001). At each of the postsurgical time points (Days 1, 8, 15, and 29), proportionally more bromfenac 0.075%-treated subjects (76.8%, 90.5%, 92.9%, and 85.1%, respectively) had no pain (a VAS score of 0) compared with the vehicle-treated subjects (48.2%, 38.8%, 42.4%, and 47.1%, respectively), and at each time point, these differences in proportions were statistically significant (P<0.001). More subjects in the bromfenac 0.075% group had complete ACF resolution (151/167; 90.4%) compared to those in the vehicle group (54/85; 63.5%). There were no new safety signals reported. Conclusion Bromfenac 0.075% in DuraSite is safe, well tolerated, and effective at reducing inflammation and preventing pain associated with cataract surgery. PMID:27920490

  8. Micromachined microwave signal control device and method for making same

    DOEpatents

    Forman, Michael A [San Francisco, CA

    2008-09-02

    A method for fabricating a signal controller, e.g., a filter or a switch, for a coplanar waveguide during the LIGA fabrication process of the waveguide. Both patterns for the waveguide and patterns for the signal controllers are created on a mask. Radiation travels through the mask and reaches a photoresist layer on a substrate. The irradiated portions are removed and channels are formed on the substrate. A metal is filled into the channels to form the conductors of the waveguide and the signal controllers. Micromachined quasi-lumped elements are used alone or together as filters. The switch includes a comb drive, a spring, a metal plunger, and anchors.

  9. Method for making a micromachined microwave signal control device

    DOEpatents

    Forman, Michael A [Mountain House, CA

    2011-02-15

    A method for fabricating a signal controller, e.g., a filter or a switch, for a coplanar waveguide during the LIGA fabrication process of the waveguide. Both patterns for the waveguide and patterns for the signal controllers are created on a mask. Radiation travels through the mask and reaches a photoresist layer on a substrate. The irradiated portions are removed and channels are formed on the substrate. A metal is filled into the channels to form the conductors of the waveguide and the signal controllers. Micromachined quasi-lumped elements are used alone or together as filters. The switch includes a comb drive, a spring, a metal plunger, and anchors.

  10. Validation of Recipes for Double-Blind Placebo-Controlled Challenges With Milk, Egg White, and Hazelnut.

    PubMed

    González-Mancebo, E; Alonso Díaz de Durana, M D; García Estringana, Y; Meléndez Baltanás, A; Rodriguez-Alvarez, M; de la Hoz Caballer, B; Del Prado, N; Fernández-Rivas, M

    The double-blind, placebo-controlled food challenge (DBPCFC) is considered the definitive diagnostic test for food allergy. Nevertheless, validated recipes for masking the foods are scarce, have not been standardized, and differ between centers. Sensory evaluation techniques such as the triangle test are necessary to validate the recipes used for DBPCFC. We developed 3 recipes for use in DBPCFC with milk, egg white, and hazelnut and used the triangle test to validate them in a 2-phase study in which 197 volunteers participated. In each phase, participants tried 3 samples (2 active-1 placebo or 2 placebo-1 active) and had to identify the odd one. In phase 1, the 3 samples were given simultaneously, whereas in phase 2, the 3 samples of foods that failed validation in phase 1 were given sequentially. A visual analog scale (VAS) ranging from 1 to 10 was used to evaluate how much participants liked the recipes. In phase 1, the egg white recipe was validated (n=89 volunteers, 38.9% found the odd sample, P=.16). Milk and hazelnut recipes were validated in phase 2 (for both foods, n=30 participants, 36.7% found the odd sample, P=.36). Median VAS scores for the 3 recipes ranged from 6.6 to 9.7. We used sensory testing to validate milk, egg white, and hazelnut recipes for use in DBPCFC. The validated recipes are easy to prepare in a clinical setting, provide the equivalent of 1 serving dose, and were liked by most participants.

  11. Randomized, Double-Blinded, Double-Dummy, Active-Controlled, and Multiple-Dose Clinical Study Comparing the Efficacy and Safety of Mulberry Twig (Ramulus Mori, Sangzhi) Alkaloid Tablet and Acarbose in Individuals with Type 2 Diabetes Mellitus

    PubMed Central

    Chen, Yao

    2016-01-01

    Aims. To evaluate the efficacy and safety of mulberry twig alkaloid (SZ-A) tablet compared with acarbose in patients with type 2 diabetes. Methods. This clinical trial enrolled 38 patients who were randomized into two groups (SZ-A: 23; acarbose: 15) and were treated for 24 weeks. Patients and clinical trial staffs were masked to treatment assignment throughout the study. The primary outcome measures were glycated hemoglobin (HbA1c) and 1-hour and 2-hour postprandial and fasting plasma glucose levels from baseline to the end of treatment. Analysis included all patients who completed this study. Results. By the end of this study, HbA1c level in SZ-A group was decreased from baseline significantly (P < 0.001). No significant difference was found when compared with acarbose group (P = 0.652). Similarly, 1-hour and 2-hour postprandial plasma glucose levels in SZ-A group were decreased from baseline statistically (P < 0.05), without any significant differences compared with acarbose group (P = 0.748 and 0.558, resp.). The fasting plasma glucose levels were not significantly changed in both groups. One of 23 patients in SZ-A group (4.76%) and 5 of 15 patients in acarbose group (33.33%) suffered from gastrointestinal adverse events. Conclusions. Compared with acarbose, SZ-A tablet was effective and safe in glycemic control in patients with type 2 diabetes. PMID:27547230

  12. Orientation masking and cross-orientation suppression (XOS): implications for estimates of filter bandwidth.

    PubMed

    Meese, Tim S; Holmes, David J

    2010-10-01

    Most contemporary models of spatial vision include a cross-oriented route to suppression (masking from a broadly tuned inhibitory pool), which is most potent at low spatial and high temporal frequencies (T. S. Meese & D. J. Holmes, 2007). The influence of this pathway can elevate orientation-masking functions without exciting the target mechanism, and because early psychophysical estimates of filter bandwidth did not accommodate this, it is likely that they have been overestimated for this corner of stimulus space. Here we show that a transient 40% contrast mask causes substantial binocular threshold elevation for a transient vertical target, and this declines from a mask orientation of 0° to about 40° (indicating tuning), and then more gently to 90°, where it remains at a factor of ∼4. We also confirm that cross-orientation masking is diminished or abolished at high spatial frequencies and for sustained temporal modulation. We fitted a simple model of pedestal masking and cross-orientation suppression (XOS) to our data and those of G. C. Phillips and H. R. Wilson (1984) and found the dependency of orientation bandwidth on spatial frequency to be much less than previously supposed. An extension of our linear spatial pooling model of contrast gain control and dilution masking (T. S. Meese & R. J. Summers, 2007) is also shown to be consistent with our results using filter bandwidths of ±20°. Both models include tightly and broadly tuned components of divisive suppression. More generally, because XOS and/or dilution masking can affect the shape of orientation-masking curves, we caution that variations in bandwidth estimates might reflect variations in processes that have nothing to do with filter bandwidth.

  13. Improving the CD linearity and proximity performance of photomasks written on the Sigma7500-II DUV laser writer through embedded OPC

    NASA Astrophysics Data System (ADS)

    Österberg, Anders; Ivansen, Lars; Beyerl, Angela; Newman, Tom; Bowhill, Amanda; Sahouria, Emile; Schulze, Steffen

    2007-10-01

    Optical proximity correction (OPC) is widely used in wafer lithography to produce a printed image that best matches the design intent while optimizing CD control. OPC software applies corrections to the mask pattern data, but in general it does not compensate for the mask writer and mask process characteristics. The Sigma7500-II deep-UV laser mask writer projects the image of a programmable spatial light modulator (SLM) using partially coherent optics similar to wafer steppers, and the optical proximity effects of the mask writer are in principle correctable with established OPC methods. To enhance mask patterning, an embedded OPC function, LinearityEqualize TM, has been developed for the Sigma7500- II that is transparent to the user and which does not degrade mask throughput. It employs a Calibre TM rule-based OPC engine from Mentor Graphics, selected for the computational speed necessary for mask run-time execution. A multinode cluster computer applies optimized table-based CD corrections to polygonized pattern data that is then fractured into an internal writer format for subsequent data processing. This embedded proximity correction flattens the linearity behavior for all linewidths and pitches, which targets to improve the CD uniformity on production photomasks. Printing results show that the CD linearity is reduced to below 5 nm for linewidths down to 200 nm, both for clear and dark and for isolated and dense features, and that sub-resolution assist features (SRAF) are reliably printed down to 120 nm. This reduction of proximity effects for main mask features and the extension of the practical resolution for SRAFs expands the application space of DUV laser mask writing.

  14. The Effect of Otitis Media with Effusion on the Masking-Level Difference and the Auditory Brainstem Response.

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Grose, John H.

    1993-01-01

    This study of 14 children (ages 5-9) with a history of otitis media with effusion found that subjects had significantly reduced masking-level differences (MLD) compared to controls. Results suggest that the reduction in MLD may be related to abnormal brainstem processing. (Author/JDD)

  15. Directional Effects between Rapid Auditory Processing and Phonological Awareness in Children

    ERIC Educational Resources Information Center

    Johnson, Erin Phinney; Pennington, Bruce F.; Lee, Nancy Raitano; Boada, Richard

    2009-01-01

    Background: Deficient rapid auditory processing (RAP) has been associated with early language impairment and dyslexia. Using an auditory masking paradigm, children with language disabilities perform selectively worse than controls at detecting a tone in a backward masking (BM) condition (tone followed by white noise) compared to a forward masking…

  16. Informational Masking and Spatial Hearing in Listeners with and without Unilateral Hearing Loss

    ERIC Educational Resources Information Center

    Rothpletz, Ann M.; Wightman, Frederic L.; Kistler, Doris J.

    2012-01-01

    Purpose: This study assessed selective listening for speech in individuals with and without unilateral hearing loss (UHL) and the potential relationship between spatial release from informational masking and localization ability in listeners with UHL. Method: Twelve adults with UHL and 12 normal-hearing controls completed a series of monaural and…

  17. Backward Masking: Evidence of Reduced Subcortical Amygdala Engagement in Autism

    ERIC Educational Resources Information Center

    Hall, Geoffrey B. C.; West, C. Dianne; Szatmari, Peter

    2007-01-01

    Recent data suggest that subthreshold presentation of emotional information is relayed to the amygdala along subcortical pathways. We examined the effect of backward masked neutral and anxious faces on the social decisions of a group of high functioning children with autism ages 7-13 years and matched controls. Participants were asked to select…

  18. Short-term visual deprivation can enhance spatial release from masking.

    PubMed

    Pagé, Sara; Sharp, Andréanne; Landry, Simon P; Champoux, François

    2016-08-15

    This research aims to study the effect of short-term visual deprivation on spatial release from masking, a major component of the cocktail party effect that allows people to detect an auditory target in noise. The Masking Level Difference (MLD) test was administered on healthy individuals over three sessions: before (I) and after 90min of visual deprivation (II), and after 90min of re-exposure to light (III). A non-deprived control group performed the same tests, but remained sighted between sessions I and II. The non-deprived control group displayed constant results across sessions. However, performance in the MLD test was improved following short-term visual deprivation and performance returned to pre-deprivation values after light re-exposure. This study finds that short-term visual deprivation transiently enhances the spatial release from masking. These data suggest the significant potential for enhancing a process involved in the cocktail party effect in normally developing individuals and adds to an emerging literature on the potential to enhance auditory ability after only a brief period of visual deprivation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Audio-vocal responses of vocal fundamental frequency and formant during sustained vowel vocalizations in different noises.

    PubMed

    Lee, Shao-Hsuan; Hsiao, Tzu-Yu; Lee, Guo-She

    2015-06-01

    Sustained vocalizations of vowels [a], [i], and syllable [mə] were collected in twenty normal-hearing individuals. On vocalizations, five conditions of different audio-vocal feedback were introduced separately to the speakers including no masking, wearing supra-aural headphones only, speech-noise masking, high-pass noise masking, and broad-band-noise masking. Power spectral analysis of vocal fundamental frequency (F0) was used to evaluate the modulations of F0 and linear-predictive-coding was used to acquire first two formants. The results showed that while the formant frequencies were not significantly shifted, low-frequency modulations (<3 Hz) of F0 significantly increased with reduced audio-vocal feedback across speech sounds and were significantly correlated with auditory awareness of speakers' own voices. For sustained speech production, the motor speech controls on F0 may depend on a feedback mechanism while articulation should rely more on a feedforward mechanism. Power spectral analysis of F0 might be applied to evaluate audio-vocal control for various hearing and neurological disorders in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Palatability of a Novel Oral Formulation of Prednisone in Healthy Young Adults

    PubMed Central

    Bai, Shasha; Dormer, Nathan; Shoults, Catherine; Meyer, Amanda; Pierce, Carol D'Ann; Neville, Kathleen A.; Kearns, Gregory L.

    2017-01-01

    Objectives Prednisone is a widely used anti-inflammatory for a variety of conditions. While oral liquid formulations of prednisone enable weight-based dosing, children frequently find them to be objectionable due to bitter taste. This limitation of prednisone can adversely impact patient acceptance and may result in non-compliance. Efforts to mask flavors often result in poorly controlled, heterogeneous particle distributions and can provide ineffective taste masking. The present work utilized a novel drug delivery technology developed by Orbis Biosciences, Inc., to create an oral taste-masked formulation of prednisone. Methods The study examined the palatability of Orbis’ microsphere prednisone formulation in healthy young adults (n=24). Four test articles were used in the study including a reference formulation (Roxane Laboratories), a control, and the test formulation (Orbis) prepared in two different ways. Study participants were randomized in a crossover design. Key Findings Results indicated that the test prednisone formulation was indistinguishable from the control, and both were preferable to the reference formulation in every category of palatability assessed using a validated 9-point Hedonic Scale. The data also suggested that preparing the microsphere suspension immediately prior to administration results in the most ideal palatability properties. Conclusions In conclusion, the novel microsphere formulation technology was effective in taste-masking prednisone. PMID:28271493

  1. Inhibitory masking controls the threshold sensitivity of retinal ganglion cells

    PubMed Central

    Pan, Feng; Toychiev, Abduqodir; Zhang, Yi; Atlasz, Tamas; Ramakrishnan, Hariharasubramanian; Roy, Kaushambi; Völgyi, Béla; Akopian, Abram

    2016-01-01

    Key points Retinal ganglion cells (RGCs) in dark‐adapted retinas show a range of threshold sensitivities spanning ∼3 log units of illuminance.Here, we show that the different threshold sensitivities of RGCs reflect an inhibitory mechanism that masks inputs from certain rod pathways.The masking inhibition is subserved by GABAC receptors, probably on bipolar cell axon terminals.The GABAergic masking inhibition appears independent of dopaminergic circuitry that has been shown also to affect RGC sensitivity.The results indicate a novel mechanism whereby inhibition controls the sensitivity of different cohorts of RGCs. This can limit and thereby ensure that appropriate signals are carried centrally in scotopic conditions when sensitivity rather than acuity is crucial. Abstract The responses of rod photoreceptors, which subserve dim light vision, are carried through the retina by three independent pathways. These pathways carry signals with largely different sensitivities. Retinal ganglion cells (RGCs), the output neurons of the retina, show a wide range of sensitivities in the same dark‐adapted conditions, suggesting a divergence of the rod pathways. However, this organization is not supported by the known synaptic morphology of the retina. Here, we tested an alternative idea that the rod pathways converge onto single RGCs, but inhibitory circuits selectively mask signals so that one pathway predominates. Indeed, we found that application of GABA receptor blockers increased the sensitivity of most RGCs by unmasking rod signals, which were suppressed. Our results indicate that inhibition controls the threshold responses of RGCs under dim ambient light. This mechanism can ensure that appropriate signals cross the bottleneck of the optic nerve in changing stimulus conditions. PMID:27350405

  2. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    PubMed

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to < 5/h on a titration study. However, it was not previously known whether switching from one CPAP mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, p<0.001). All 14 subjects had a higher residual AHI with the oronasal versus nasal mask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of < 5/h in the laboratory. A higher residual AHI was seen in all patients with the use of an oronasal mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Nanoimprint system development and status for high volume semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Hiura, Hiromi; Takabayashi, Yukio; Takashima, Tsuneo; Emoto, Keiji; Choi, Jin; Schumaker, Phil

    2016-10-01

    Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash Imprint Lithography* (J-FIL*) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed, leaving a patterned resist on the substrate. There are many criteria that determine whether a particular technology is ready for wafer manufacturing. For imprint lithography, recent attention has been given to the areas of overlay, throughput, defectivity, and mask replication. This paper reviews progress in these critical areas. Recent demonstrations have proven that mix and match overlay of less than 5nm can achieved. Further reductions require a higher order correction system. Modeling and experimental data are presented which provide a path towards reducing the overlay errors to less than 3nm. Throughput is mainly impacted by the fill time of the relief images on the mask. Improvement in resist materials provides a solution that allows 15 wafers per hour per station, or a tool throughput of 60 wafers per hour. Defectivity and mask life play a significant role relative to meeting the cost of ownership (CoO) requirements in the production of semiconductor devices. Hard particles on a wafer or mask create the possibility of inducing a permanent defect on the mask that can impact device yield and mask life. By using material methods to reduce particle shedding and by introducing an air curtain system, the lifetime of both the master mask and the replica mask can be extended. In this work, we report results that demonstrate a path towards achieving mask lifetimes of better than 1000 wafers. Finally, on the mask side, a new replication tool, the FPA-1100NR2 is introduced. Mask replication is required for nanoimprint lithography (NIL), and criteria that are crucial to the success of a replication platform include both particle control and IP accuracy. In particular, by improving the specifications on the mask chuck, residual errors of only 1nm can be realized.

  4. Bimatoprost 0.03% preservative-free ophthalmic solution versus bimatoprost 0.03% ophthalmic solution (Lumigan) for glaucoma or ocular hypertension: a 12-week, randomised, double-masked trial

    PubMed Central

    Day, Douglas G; Walters, Thomas R; Schwartz, Gail F; Mundorf, Thomas K; Liu, Charlie; Schiffman, Rhett M; Bejanian, Marina

    2013-01-01

    Background/Aim To evaluate efficacy and safety of bimatoprost 0.03% preservative-free (PF) ophthalmic solution versus bimatoprost 0.03% (Lumigan) ophthalmic solution for glaucoma or ocular hypertension. Methods In this double-masked, parallel-group study, patients were randomised to bimatoprost PF or bimatoprost for 12 weeks. The primary analysis for non-inferiority was change from baseline in worse eye intraocular pressure (IOP) in the per-protocol population at week 12. For equivalence, it was average eye IOP in the intent-to-treat population at each time point at weeks 2, 6 and 12. Results 597 patients were randomised (bimatoprost PF, n=302 and bimatoprost, n=295). The 95% CI upper limit for worse eye IOP change from baseline was <1.5 mm Hg at each week 12 time point, meeting prespecified non-inferiority criteria. The 95% CI upper limit for the treatment difference for average IOP was 0.69 mm Hg and the lower limit was −0.50 mm Hg at all follow-up time points (hours 0, 2 and 8 at weeks 2, 6 and 12), meeting equivalence criteria. Both treatments showed decreases in mean average eye IOP at all follow-up time points (p<0.001), were safe and well tolerated. Conclusions Bimatoprost PF is non-inferior and equivalent to bimatoprost in its ability to reduce IOP-lowering with a safety profile similar to bimatoprost. PMID:23743437

  5. A Randomized Comparison of Aripiprazole and Risperidone for the Acute Treatment of First-Episode Schizophrenia and Related Disorders: 3-Month Outcomes

    PubMed Central

    Robinson, Delbert G.; Gallego, Juan A.; John, Majnu; Petrides, Georgios; Hassoun, Youssef; Zhang, Jian-Ping; Lopez, Leonardo; Braga, Raphael J.; Sevy, Serge M.; Addington, Jean; Kellner, Charles H.; Tohen, Mauricio; Naraine, Melissa; Bennett, Natasha; Greenberg, Jessica; Lencz, Todd; Correll, Christoph U.; Kane, John M.; Malhotra, Anil K.

    2015-01-01

    Research findings are particularly important for medication choice for first-episode patients as individual prior medication response to guide treatment decisions is unavailable. We describe the first large-scale double-masked randomized comparison with first-episode patients of aripiprazole and risperidone, 2 commonly used first-episode treatment agents. One hundred ninety-eight participants aged 15–40 years with schizophrenia, schizophreniform disorder, schizoaffective disorder or psychotic disorder Not Otherwise Specified, and who had been treated in their lifetime with antipsychotics for 2 weeks or less were randomly assigned to double-masked aripiprazole (5–30mg/d) or risperidone (1–6mg/d) and followed for 12 weeks. Positive symptom response rates did not differ (62.8% vs 56.8%) nor did time to response. Aripiprazole-treated participants had better negative symptom outcomes but experienced more akathisia. Body mass index change did not differ between treatments but advantages were found for aripiprazole treatment for total and low-density lipoprotein cholesterol, fasting glucose, and prolactin levels. Post hoc analyses suggested advantages for aripiprazole on depressed mood. Overall, if the potential for akathisia is a concern, low-dose risperidone as used in this trial maybe a preferred choice over aripiprazole. Otherwise, aripiprazole would be the preferred choice over risperidone in most situations based upon metabolic outcome advantages and some symptom advantages within the context of similar positive symptom response between medications. PMID:26338693

  6. Awareness Becomes Necessary Between Adaptive Pattern Coding of Open and Closed Curvatures

    PubMed Central

    Sweeny, Timothy D.; Grabowecky, Marcia; Suzuki, Satoru

    2012-01-01

    Visual pattern processing becomes increasingly complex along the ventral pathway, from the low-level coding of local orientation in the primary visual cortex to the high-level coding of face identity in temporal visual areas. Previous research using pattern aftereffects as a psychophysical tool to measure activation of adaptive feature coding has suggested that awareness is relatively unimportant for the coding of orientation, but awareness is crucial for the coding of face identity. We investigated where along the ventral visual pathway awareness becomes crucial for pattern coding. Monoptic masking, which interferes with neural spiking activity in low-level processing while preserving awareness of the adaptor, eliminated open-curvature aftereffects but preserved closed-curvature aftereffects. In contrast, dichoptic masking, which spares spiking activity in low-level processing while wiping out awareness, preserved open-curvature aftereffects but eliminated closed-curvature aftereffects. This double dissociation suggests that adaptive coding of open and closed curvatures straddles the divide between weakly and strongly awareness-dependent pattern coding. PMID:21690314

  7. Bubble masks for time-encoded imaging of fast neutrons.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brubaker, Erik; Brennan, James S.; Marleau, Peter

    2013-09-01

    Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is inducedtypically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixedmore » blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gapsbubblespropagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.« less

  8. Intensive two-day cognitive-behavioral intervention decreases cortisol secretion in soldiers suffering from specific phobia to wear protective mask.

    PubMed

    Brand, Serge; Annen, Hubert; Holsboer-Trachsler, Edith; Blaser, Andreas

    2011-10-01

    Wearing a protective mask is compulsory for those in professions such as fire-fighters, rescue personnel and soldiers. The phobia to wear a protective mask is considered a specific claustrophobia and may become of major concern during military service. To date, no data are available with respect to the hypothalamus-pituitary-adrenocortical system activity (HPA SA) for both the so-called protective mask phobia (PMP) and its treatment. The aim of the present study was three-fold: 1) to assess HPA SA in soldiers suffering from PMP before and after intensive cognitive-behavioral treatment, 2) to compare these data with controls, and 3) to relate these data to subjective sleep. 46 Swiss Army recruits suffering from PMP were enrolled in a two-day intensive treatment course. During initial and final assessments, saliva was sampled to analyse HPA SA via salivary cortisol; saliva samples were also gathered in the morning. For comparison, saliva samples were gathered of 39 Emergency Rescue Service (ERS) recruits. All participants also completed a questionnaire related to sleep and to anxiety. Compared to controls from the ERS, among army recruits suffering from PMP, cortisol secretion was significantly higher during initial and final assessments, and in the morning. Cortisol secretion decreased from initial and final assessment. Subjectively assessed sleep was more impaired in recruits suffering from PMP compared to controls. After cognitive-behavioral treatment, all recruits suffering from PMP were able to wear the protective mask. Specific phobia about wearing a protective mask is treatable via a two-day intensive course. Treatment success is reflected in modified HPA SA. Methodology and results may be transferred to treat patients suffering from sleep apnea syndrome and presenting high anxiety about wearing continuous positive airway pressure devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Laryngeal mask airway for airway control during percutaneous dilatational tracheostomy.

    PubMed

    Pratt, T; Bromilow, J

    2011-11-01

    Percutaneous dilatational tracheostomy is a common bedside procedure in critical care for patients requiring prolonged mechanical ventilation. The traditional technique requires withdrawal of the endotracheal tube to a proximal position to facilitate tracheostomy insertion, but this carries the risk of inadvertent extubation and does not prevent cuff rupture. Use of a supraglottic airway such as the laryngeal mask airway may avoid these risks and could provide a safe alternative to the endotracheal tube. We present an appraisal of the literature to date. We found reasonable evidence to show improved ventilation and bronchoscopic visualisation with the laryngeal mask airway, but this has not been translated into improved outcome. There is currently insufficient evidence to draw conclusions about the safety of the laryngeal mask airway during percutaneous dilatational tracheostomy.

  10. Improved decryption quality and security of a joint transform correlator-based encryption system

    NASA Astrophysics Data System (ADS)

    Vilardy, Juan M.; Millán, María S.; Pérez-Cabré, Elisabet

    2013-02-01

    Some image encryption systems based on modified double random phase encoding and joint transform correlator architecture produce low quality decrypted images and are vulnerable to a variety of attacks. In this work, we analyse the algorithm of some reported methods that optically implement the double random phase encryption in a joint transform correlator. We show that it is possible to significantly improve the quality of the decrypted image by introducing a simple nonlinear operation in the encrypted function that contains the joint power spectrum. This nonlinearity also makes the system more resistant to chosen-plaintext attacks. We additionally explore the system resistance against this type of attack when a variety of probability density functions are used to generate the two random phase masks of the encryption-decryption process. Numerical results are presented and discussed.

  11. Mask Ventilation during Induction of General Anesthesia: Influences of Obstructive Sleep Apnea.

    PubMed

    Sato, Shin; Hasegawa, Makoto; Okuyama, Megumi; Okazaki, Junko; Kitamura, Yuji; Sato, Yumi; Ishikawa, Teruhiko; Sato, Yasunori; Isono, Shiroh

    2017-01-01

    Depending on upper airway patency during anesthesia induction, tidal volume achieved by mask ventilation may vary. In 80 adult patients undergoing general anesthesia, the authors tested a hypothesis that tidal volume during mask ventilation is smaller in patients with sleep-disordered breathing priorly defined as apnea hypopnea index greater than 5 per hour. One-hand mask ventilation with a constant ventilator setting (pressure-controlled ventilation) was started 20 s after injection of rocuronium and maintained for 1 min during anesthesia induction. Mask ventilation efficiency was assessed by the breath number needed to initially exceed 5 ml/kg ideal body weight of expiratory tidal volume (primary outcome) and tidal volumes (secondary outcomes) during initial 15 breaths (UMIN000012494). Tidal volume progressively increased by more than 70% in 1 min and did not differ between sleep-disordered breathing (n = 42) and non-sleep-disordered breathing (n = 38) patients. In post hoc subgroup analyses, the primary outcome breath number (mean [95% CI], 5.7 [4.1 to 7.3] vs. 1.7 [0.2 to 3.2] breath; P = 0.001) and mean tidal volume (6.5 [4.6 to 8.3] vs. 9.6 [7.7 to 11.4] ml/kg ideal body weight; P = 0.032) were significantly smaller in 20 sleep-disordered breathing patients with higher apnea hypopnea index (median [25th to 75th percentile]: 21.7 [17.6 to 31] per hour) than in 20 non-sleep disordered breathing subjects with lower apnea hypopnea index (1.0 [0.3 to 1.5] per hour). Obesity and occurrence of expiratory flow limitation during one-hand mask ventilation independently explained the reduction of efficiency of mask ventilation, while the use of two hands effectively normalized inefficient mask ventilation during one-hand mask ventilation. One-hand mask ventilation is difficult in patients with obesity and severe sleep-disordered breathing particularly when expiratory flow limitation occurs during mask ventilation.

  12. Compliance with the Use of Medical and Cloth Masks Among Healthcare Workers in Vietnam.

    PubMed

    Chughtai, Abrar Ahmad; Seale, Holly; Dung, Tham Chi; Hayen, Andrew; Rahman, Bayzidur; Raina MacIntyre, C

    2016-06-01

    Masks are often worn in healthcare settings to prevent the spread of infection from healthcare workers (HCWs) to patients. Masks are also used to protect the employee from patient-generated infectious organisms but poor compliance can reduce efficacy. The aim of this study was to examine the factors influencing compliance with the use of medical and cloth masks amongst hospital HCWs. HCWs compliance with the use of medical and cloth masks was measured over a 4-week period in a randomized controlled trial in Vietnam. HCWs were instructed to record their daily activities in diary cards. Demographic, clinical, and diary card data were used to determine the predictors of compliance and the relationship of compliance with infection outcomes. Compliance rates for both medical and cloth masks decreased during the 4 weeks: medical mask use decreased from 77 to 68% (P < 0.001) and cloth masks from 78 to 69% (P < 0.001). The presence of adverse events (adjusted RR 0.90, 95% CI 0.85-0.95), and performing aerosol-generating procedures (adjusted RR 0.78, 95% CI 0.73-0.82) were negatively associated with compliance, while contact with febrile respiratory illness patients was positively associated (adjusted RR 1.14, 95% CI 1.07-1.20). Being compliant with medical or cloth masks use (average use ≥70% of working time) was not associated with clinical respiratory illness, influenza-like illness, and laboratory-confirmed viral infection. Understanding the factors that affect compliance is important for the occupational health and safety of HCWs. New strategies and tools should be developed to increase compliance of HCWs. The presence of adverse events such as discomfort and breathing problems may be the main reasons for the low compliance with mask use and further studies should be conducted to improve the design/material of masks to improve comfort for the wearer. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  13. Non-commercial vs. commercial clinical trials: a retrospective study of the applications submitted to a research ethics committee.

    PubMed

    Fuentes Camps, Inmaculada; Rodríguez, Alexis; Agustí, Antonia

    2018-06-01

    There are many difficulties in undertaking independent clinical research without support from the pharmaceutical industry. In this retrospective observational study, some design characteristics, the clinical trial public register and the publication rate of noncommercial clinical trials were compared to those of commercial clinical trials. A total of 809 applications of drug-evaluation clinical trials were submitted from May 2004 to May 2009 to the research ethics committee of a tertiary hospital, and 16.3% of trials were noncommercial. They were mainly phase IV, multicentre national, and unmasked controlled trials, compared to the commercial trials that were mainly phase II or III, multicentre international, and double-blind masked trials. The commercial trials were registered and published more often than noncommercial trials. More funding for noncommercial research is still needed. The results of the research, commercial or noncommercial, should be disseminated in order not to compromise either its scientific or its social value. © 2018 The British Pharmacological Society.

  14. Gate-controlled quantum collimation in nanocolumn resonant tunneling transistors.

    PubMed

    Wensorra, J; Lepsa, M I; Trellenkamp, S; Moers, J; Indlekofer, K M; Lüth, H

    2009-11-18

    Nanoscaled resonant tunneling transistors (RTT) based on MBE-grown GaAs/AlAs double-barrier quantum well (DBQW) structures have been fabricated by a top-down approach using electron-beam lithographic definition of the vertical nanocolumns. In the preparation process, a reproducible mask alignment accuracy of below 10 nm has been achieved and the all-around metal gate at the level of the DBQW structure has been positioned at a distance of about 20 nm relative to the semiconductor nanocolumn. Due to the specific doping profile n++/i/n++ along the transistor nanocolumn, a particular confining potential is established for devices with diameters smaller than 70 nm, which causes a collimation effect of the propagating electrons. Under these conditions, room temperature optimum performance of the nano-RTTs is achieved with peak-to-valley current ratios above 2 and a peak current swing factor of about 6 for gate voltages between -6 and +6 V. These values indicate that our nano-RTTs can be successfully used in low power fast nanoelectronic circuits.

  15. Clobetasol propionate shampoo 0.05%: a new option to treat patients with moderate to severe scalp psoriasis.

    PubMed

    Jarratt, Michael; Breneman, Debra; Gottlieb, Alice B; Poulin, Yves; Liu, Yin; Foley, Valerie

    2004-01-01

    Psoriasis is a chronic, papulosquamous condition that affects up to 2% of the U.S. population. Approximately 50% of patients with psoriasis have involvement of the scalp. This was a multicentre, randomized, vehicle-controlled, double-masked and parallel-group study. The aim was to evaluate the efficacy and safety of clobetasol propionate shampoo, 0.05% versus its corresponding vehicle in subjects aged 12 years and older with moderate to severe scalp psoriasis over a treatment period of 4 weeks. Recurrence of scalp psoriasis was assessed during a two week follow-up period. A total of 142 subjects were treated. Results after 4 weeks demonstrated that clobetasol propionate shampoo, 0.05% was with a similar safety profile significantly more effective than its vehicle. The novel short contact shampoo formulation of clobetasol propionate is convenient and efficacious and minimizes systemic exposure while being efficient, safe and well-tolerated in the treatment of moderate to severe scalp psoriasis.

  16. Self-aligned blocking integration demonstration for critical sub-40nm pitch Mx level patterning

    NASA Astrophysics Data System (ADS)

    Raley, Angélique; Mohanty, Nihar; Sun, Xinghua; Farrell, Richard A.; Smith, Jeffrey T.; Ko, Akiteru; Metz, Andrew W.; Biolsi, Peter; Devilliers, Anton

    2017-04-01

    Multipatterning has enabled continued scaling of chip technology at the 28nm node and beyond. Selfaligned double patterning (SADP) and self-aligned quadruple patterning (SAQP) as well as Litho- Etch/Litho-Etch (LELE) iterations are widely used in the semiconductor industry to enable patterning at sub 193 immersion lithography resolutions for layers such as FIN, Gate and critical Metal lines. Multipatterning requires the use of multiple masks which is costly and increases process complexity as well as edge placement error variation driven mostly by overlay. To mitigate the strict overlay requirements for advanced technology nodes (7nm and below), a self-aligned blocking integration is desirable. This integration trades off the overlay requirement for an etch selectivity requirement and enables the cut mask overlay tolerance to be relaxed from half pitch to three times half pitch. Selfalignement has become the latest trend to enable scaling and self-aligned integrations are being pursued and investigated for various critical layers such as contact, via, metal patterning. In this paper we propose and demonstrate a low cost flexible self-aligned blocking strategy for critical metal layer patterning for 7nm and beyond from mask assembly to low -K dielectric etch. The integration is based on a 40nm pitch SADP flow with 2 cut masks compatible with either cut or block integration and employs dielectric films widely used in the back end of the line. As a consequence this approach is compatible with traditional etch, deposition and cleans tools that are optimized for dielectric etches. We will review the critical steps and selectivities required to enable this integration along with bench-marking of each integration option (cut vs. block).

  17. Temperature stability of Al(x)Ga(1-x)As (x = 0-1) thermal oxide masks for selective-area epitaxy

    NASA Technical Reports Server (NTRS)

    Jones, Stephen H.; Lau, Kei May; Pouch, John J.

    1988-01-01

    The use of thermal oxides of Al(x)Ga(1-x)As (x = 0-1) as masking materials for selective-area epitaxy by a organometallic chemical-vapor deposition has been investigated. It was found that the thermal oxide of GaAs is only applicable for low growth temperatures (less than or equal to 600 C), and the addition of aluminum significantly improves the thermal stability of the oxide. The oxide of Al(0.4)Ga(0.6)As is suitable for high-temperature deposition, but there are criteria for the thickness and oxidation temperature. Thin layers of AlAs oxidized at 475 C are excellent masks and allow precise thickness control. Promising results of selective-area deposition using these aluminum oxide masks have been obtained. High-quality single crystal grew in mask openings uniformly surrounded by dense and fine-grain polycrystalline deposits, producing a planar duplication of the original pattern.

  18. Unconscious and out of control: subliminal priming is insensitive to observer expectations.

    PubMed

    Cressman, Erin K; Lam, Melanie Y; Franks, Ian M; Enns, James T; Chua, Romeo

    2013-09-01

    We asked whether the influence of an invisible prime on movement is dependent on conscious movement expectations. Participants reached to a central target, which triggered a directional prime-mask arrow sequence. Participants were instructed that the visible arrows (masks) would most often signal a movement modification in a specific (biased) direction. Kinematic analyses revealed that responses to the visible mask were influenced by participants' intentional bias, as movements were fastest when the more probable mask was displayed. In addition, responses were influenced by the invisible prime without regard to its relationship to the more probable mask. Analysis of the time of initial trajectory modifications revealed that both primes influenced responses in a similar manner after accounting for participants' bias. These results imply that invisible stimuli automatically activate their associated responses and that unconscious priming of the motor system is insensitive to the conscious expectations of the participant making the pointing movements. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. New operational technology of intrauterine ventilation the fetus lungs by breathing gas

    NASA Astrophysics Data System (ADS)

    Urakov, A. L.; Nikityuk, D. B.; Urakova, N. A.; Kasankin, A. A.; Chernova, L. V.; Dementiev, V. B.

    2015-11-01

    New operational technology for elimination intrauterine hypoxia and asphyxia of the fetus using endoscopic artificial ventilation lungs by respiratory gas was developed. For intrauterine ventilation of fetal lung it is proposed to enter into the uterus a special breathing mask and wear it on the head of the fetus using the original endoscopic technology. The breathing mask, developed by us is connected with external breathing apparatus with a hose. The device is called "intrauterine aqualung". Intrauterine aqualung includes a ventilator and breathing circuit with a special fold-out breathing mask that is put on inside the uterus on the head of fetus like a mesh hat. Controlled by ultrasound the technology of the introduction of the mask inside of the uterus through the natural opening in the cervix and technology of putting on the respiratory mask on the head of the fetus with its head previa were developed. The technology intrauterine ventilation of the fetus lungs by respiratory gas was developed.

  20. Awareness of subtle emotional feelings: a comparison of long-term meditators and nonmeditators.

    PubMed

    Nielsen, Lisbeth; Kaszniak, Alfred W

    2006-08-01

    The authors explored whether meditation training to enhance emotional awareness improves discrimination of subtle emotional feelings hypothesized to guide decision-making. Long-term meditators and nonmeditators were compared on measures of self-reported valence and arousal, skin conductance response (SCR), and facial electromyography (EMG) to masked and nonmasked emotional pictures, and on measures of heartbeat detection and self-reported emotional awareness. Groups responded similarly to nonmasked pictures. In the masked condition, only controls showed discrimination in valence self-reports. However, meditators reported greater emotional clarity than controls, and meditators with higher clarity had reduced arousal and improved valence discrimination in the masked condition. These findings provide qualified support for the somatic marker hypothesis and suggest that meditation may influence how emotionally ambiguous information is processed, regulated, and represented in conscious awareness. (c) 2006 APA, all rights reserved

  1. Evoked-potential recovery during double click stimulation in a whale: a possibility of biosonar automatic gain control.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2007-01-01

    False killer whale Pseudorca crassidens auditory brainstem responses (ABR) were recorded using a double-click stimulation paradigm specifically measuring the recovery of the second response (to the test click) as a function of the inter-click interval (ICI) at various levels of the conditioning and test click. At all click intensities, the slopes of recovery functions were almost constant: 0.6-0.8 microV per ICI decade. Therefore, even when the conditioning-to-test-click level ratio was kept constant, the duration of recovery was intensity-dependent: The higher intensity the longer the recovery. The conditioning-to-test-click level ratio strongly influenced the recovery time: The higher the ratio, the longer the recovery. The dependence was almost linear using a logarithmic ICI scale with a rate of 25-30 dB per ICI decade. These data were used for modeling the interaction between the emitted click and the echo during echolocation, assuming that the two clicks simulated the transmitted and echo clicks. This simulation showed that partial masking of the echo by the preceding emitted click may explain the independence of echo-response amplitude of target distance. However, the distance range where this mechanism is effective depends on the emitted click level: The higher the level, the greater the range. @ 2007 Acoustical Society of America.

  2. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    ERIC Educational Resources Information Center

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose: This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method: The authors used noise masking to minimize auditory feedback during…

  3. To Find a Treasure: The Nuu-chah-nulth Wolf Mask

    ERIC Educational Resources Information Center

    Kruger, Arnold

    2003-01-01

    The Wolf Ritual, or Tlukwana, with its associated regalia of masks, dances, costumes, and musical instruments, was a major feature of the Nuu-chah-nulth Winter Ceremonies. In common with other Northwest Coast Native nations, the lives of the Nuu-chah-nulth people were controlled by the seasons, and following a summer and autumn of gathering and…

  4. Auditory Temporal Order Discrimination and Backward Recognition Masking in Adults with Dyslexia

    ERIC Educational Resources Information Center

    Griffiths, Yvonne M.; Hill, Nicholas I.; Bailey, Peter J.; Snowling, Margaret J.

    2003-01-01

    The ability of 20 adult dyslexic readers to extract frequency information from successive tone pairs was compared with that of IQ-matched controls using temporal order discrimination and auditory backward recognition masking (ABRM) tasks. In both paradigms, the interstimulus interval (ISI) between tones in a pair was either short (20 ms) or long…

  5. STS-26 Pilot Covey, wearing sleep mask, rests on aft flight deck

    NASA Image and Video Library

    1988-10-03

    STS026-09-021 (3 Oct 1988) --- Astronaut Richard O. Covey, STS-26 pilot, wearing sleep mask (blindfold) and a headset, props his feet under the pilots seat and rests his head and back on the aft flight deck on orbit station panels while he sleeps. At Covey's right are the mission station control panels.

  6. The role of auditory and kinaesthetic feedback mechanisms on phonatory stability in children.

    PubMed

    Rathna Kumar, S B; Azeem, Suhail; Choudhary, Abhishek Kumar; Prakash, S G R

    2013-12-01

    Auditory feedback plays an important role in phonatory control. When auditory feedback is disrupted, various changes are observed in vocal motor control. Vocal intensity and fundamental frequency (F0) levels tend to increase in response to auditory masking. Because of the close reflexive links between the auditory and phonatory systems, it is likely that phonatory stability may be disrupted when auditory feedback is disrupted or altered. However, studies on phonatory stability under auditory masking condition in adult subjects showed that most of the subjects maintained normal levels of phonatory stability. The authors in the earlier investigations suggested that auditory feedback is not the sole contributor to vocal motor control and phonatory stability, a complex neuromuscular reflex system known as kinaesthetic feedback may play a role in controlling phonatory stability when auditory feedback is disrupted or lacking. This proposes the need to further investigate this phenomenon as to whether children show similar patterns of phonatory stability under auditory masking since their neuromotor systems are still at developmental stage, less mature and are less resistant to altered auditory feedback than adults. A total of 40 normal hearing and speaking children (20 male and 20 female) between the age group of 6 and 8 years participated as subjects. The acoustic parameters such as shimmer, jitter and harmonic-to-noise ratio (HNR) were measures and compared between no masking condition (0 dB ML) and masking condition (90 dB ML). Despite the neuromotor systems being less mature in children and less resistant than adults to altered auditory feedback, most of the children in the study demonstrated increased phonatory stability which was reflected by reduced shimmer, jitter and increased HNR values. This study implicates that most of the children demonstrate well established patterns of kinaesthetic feedback, which might have allowed them to maintain normal levels of vocal motor control even in the presence of disturbed auditory feedback. Hence, it can be concluded that children also exhibit kinaesthetic feedback mechanism to control phonatory stability when auditory feedback is disrupted which in turn highlights the importance of kinaesthetic feedback to be included in the therapeutic/intervention approaches for children with hearing and neurogenic speech deficits.

  7. Does conflict control occur without awareness? Evidence from an ERP study.

    PubMed

    Wang, Baoxi; Xiang, Ling; Li, Juan

    2013-01-15

    The relationship between conflict control and awareness has attracted extensive interest. Although researchers have investigated the relationship between response conflict and awareness, it still remains unclear whether stimulus conflict can occur outside of awareness. In addition, previous studies on the role of awareness in conflict control have ignored the fact that conflict control includes both conflict detection and resolution. A modified version of the flanker task was used to manipulate stimulus and response conflicts under both masked and unmasked conditions. The masked condition elicited a sequence of distinct event-related potential components that were also observed in the unmasked condition. N2 amplitudes presented the following pattern: incongruent-eligible>incongruent-ineligible>congruent, they did not show any difference under the masked and unmasked conditions, suggesting that detection of stimulus-related conflict revealed by the comparison between incongruent-ineligible and congruent trials, and response-related conflict revealed by the comparison between incongruent-eligible and incongruent-ineligible trials can occur in the absence of awareness, and unconscious conflict detection might involve the same neural network employed for conscious conflict detection. Late positive component (LPC) amplitudes also presented as incongruent-eligible>incongruent-ineligible>congruent at CPz and Pz, irrespective of conscious awareness. However, LPC amplitudes under the masked condition were markedly reduced compared to unmasked trials. These LPC findings suggest that stimulus- and response-related conflict resolution can occur in the absence of awareness; furthermore, unconscious conflict resolution might involve a weaker cognitive control network compared to conscious conflict resolution. These findings have important implications for the theories concerning the relationship between cognitive control and awareness. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Lenslet Array to Further Suppress Star Light for Direct Exoplanet Detection

    NASA Technical Reports Server (NTRS)

    Gong, Qian; McElwain, Michael; Shiri, Ron

    2016-01-01

    Direct imaging plays a key role in the detection and characterization of exoplanets orbiting within its host star's habitable zone. Many innovative ideas for starlight suppression and wavefront control have been proposed and developed over the past decade. However, several technological challenges still lie ahead to achieve the required contrast, including controlling the observatory pointing performance, fabricating occulting masks with tight optical tolerances, developing wavefront control algorithms, controlling stray light, advancing single photon detecting detectors, and integrated system-level issues. This paper explores how a lenslet array and pinhole mask may be implemented to further suppress uncorrected starlight that leaks through the occulting mask. An external occulter, or star shade, is simulated to demonstrate this concept, although this approach can be implemented for internal coronagraphs as well. We describe how to use simple relay optics to control the scene near the inner working angle and the level of the suppression expected. Furthermore, if the lenslet array is the input to an integral field spectrograph, as planned for the WFIRST mission, the spectral content of the exoplanet atmospheres can be obtained to determine if the observed planet is habitable and ultimately, if it is inhabited.

  9. A novel methodology for litho-to-etch pattern fidelity correction for SADP process

    NASA Astrophysics Data System (ADS)

    Chen, Shr-Jia; Chang, Yu-Cheng; Lin, Arthur; Chang, Yi-Shiang; Lin, Chia-Chi; Lai, Jun-Cheng

    2017-03-01

    For 2x nm node semiconductor devices and beyond, more aggressive resolution enhancement techniques (RETs) such as source-mask co-optimization (SMO), litho-etch-litho-etch (LELE) and self-aligned double patterning (SADP) are utilized for the low k1 factor lithography processes. In the SADP process, the pattern fidelity is extremely critical since a slight photoresist (PR) top-loss or profile roughness may impact the later core trim process, due to its sensitivity to environment. During the subsequent sidewall formation and core removal processes, the core trim profile weakness may worsen and induces serious defects that affect the final electrical performance. To predict PR top-loss, a rigorous lithography simulation can provide a reference to modify mask layouts; but it takes a much longer run time and is not capable of full-field mask data preparation. In this paper, we first brought out an algorithm which utilizes multi-intensity levels from conventional aerial image simulation to assess the physical profile through lithography to core trim etching steps. Subsequently, a novel correction method was utilized to improve the post-etch pattern fidelity without the litho. process window suffering. The results not only matched PR top-loss in rigorous lithography simulation, but also agreed with post-etch wafer data. Furthermore, this methodology can also be incorporated with OPC and post-OPC verification to improve core trim profile and final pattern fidelity at an early stage.

  10. S-ketamine influences strategic allocation of attention but not exogenous capture of attention.

    PubMed

    Fuchs, Isabella; Ansorge, Ulrich; Huber-Huber, Christoph; Höflich, Anna; Lanzenberger, Rupert

    2015-09-01

    We investigated whether s-ketamine differentially affects strategic allocation of attention. In Experiment 1, (1) a less visible cue was weakly masked by the onsets of competing placeholders or (2) a better visible cue was not masked because it was presented in isolation. Both types of cue appeared more often opposite of the target (75%) than at target position (25%). With this setup, we tested for strategic attention shifts to the opposite side of the cues and for exogenous attentional capture toward the cue's side in a short cue-target interval, as well as for (reverse) cueing effects in a long cue-target interval after s-ketamine and after placebo treatment in a double-blind within-participant design. We found reduced strategic attention shifts after cues presented without placeholders for the s-ketamine compared to the placebo treatment in the short interval, indicating an early effect on the strategic allocation of attention. No differences between the two treatments were found for exogenous attentional capture by less visible cues, suggesting that s-ketamine does not affect exogenous attentional capture in the presence of competing distractors. Experiment 2 confirmed that the competing onsets of the placeholders prevented the strategic cueing effect. Taken together, the results indicate that s-ketamine affects strategic attentional capture, but not exogenous attentional capture. The findings point to a more prominent role of s-ketamine during top-down controlled forms of attention that require suppression of automatic capture than during automatic capture itself. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Perioperative effects of oral midazolam premedication in children undergoing skin laser treatment. A double-blinded randomized placebo-controlled trial.

    PubMed

    Shoroghi, Mehrdad; Arbabi, Shahriyar; Farahbakhsh, Farshid; Sheikhvatan, Mehrdad; Abbasi, Ali

    2011-08-01

    To investigate and compare the efficacy of oral midazolam with two different dosages in orange juice on perioperative hemodynamics and behavioral changes in children who underwent skin laser treatment in an academic educational Hospital. Ninety children, candidates for skin laser treatment were randomly assigned to 1 of 3 groups of 30 each: the placebo group received 0.1 ml/kg orange flavored juice, group 2 and 3 receiving 0.5 and 1 mg/kg of injectable midazolam mixed with an equal volume of orange juice, respectively. The main outcome measures included the mask acceptance, patients' behavioral scales and postoperative events. There were no significant differences in heart rate, respiratory rate, and systolic blood pressure among the three groups. However, arterial oxygen saturation was significantly reduced in those given 1 mg.kg(-1) midazolam. The median scores of anxiety, separation from parent, preparing an intravenous line, acceptance of the oxygen mask, good sedation, crying reduction and consciousness level were better in midazolam group. Postoperative agitation and re-crying were also more frequent in placebo receivers. Those given 1 mg.kg(-1) midazolam were significantly more optimal for sedation, crying, consciousness, preparing an intravenous line, and postoperative re-crying compared with 0.5 mg.kg(-1) midazolam receivers. As a preanaesthetic medication, the 1 mg.kg(-1) dose of orally given midazolam especially in a volume of orange juice and can optimize the children's behavior during skin laser treatment with no serious adverse effects, enhancing their parents' satisfactions about the sedative protocol.

  12. Joint Service Aircrew Mask (JSAM) - Tactical Aircraft (TA) A/P22P-14A Respirator Assembly (V)5: Speech Intelligibility Performance with Double Hearing Protection, HGU-84/P Flight Helmet

    DTIC Science & Technology

    2017-04-06

    Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme Test (MRT) score as listed below...Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a minimum of ten talkers and of ten...listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication 6 DISTRIBUTION STATEMENT A: Approved for public release

  13. Joint Service Aircrew Mask (JSAM) - Tactical Aircraft (TA) A/P22P-14A Respirator Assembly (V)3: Noise Attenuation and Speech Intelligibility Performance with Double Hearing Protection, HGU-68/P Flight Helmet

    DTIC Science & Technology

    2017-03-31

    dB Sound Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme Test (MRT) score as listed...below. Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a minimum of ten talkers and of ten...listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication amplification. Test must include the configurations

  14. Polymeric matrix materials for infrared metamaterials

    DOEpatents

    Dirk, Shawn M; Rasberry, Roger D; Rahimian, Kamyar

    2014-04-22

    A polymeric matrix material exhibits low loss at optical frequencies and facilitates the fabrication of all-dielectric metamaterials. The low-loss polymeric matrix material can be synthesized by providing an unsaturated polymer, comprising double or triple bonds; partially hydrogenating the unsaturated polymer; depositing a film of the partially hydrogenated polymer and a crosslinker on a substrate; and photopatterning the film by exposing the film to ultraviolet light through a patterning mask, thereby cross-linking at least some of the remaining unsaturated groups of the partially hydrogenated polymer in the exposed portions.

  15. Universal Mask Usage for Reduction of Respiratory Viral Infections After Stem Cell Transplant: A Prospective Trial.

    PubMed

    Sung, Anthony D; Sung, Julia A M; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J; Horwitz, Mitchell E

    2016-10-15

    Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010-2014) compared with the premask period (2003-2009). RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P < .001). Significant decreases occurred after both allogeneic (64/378 [16.9%] to 24/289 [8.3%], P = .001) and autologous (31/542 [5.7%] to 16/622 [2.6%], P = .007) transplants. After adjusting for multiple covariates including season and year in a segmented longitudinal analysis, the decrease in RVIs remained significant, with risk of RVI of 0.4 in patients in the mask group compared with the premask group (0.19-0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P < .001). Requiring all individuals with direct patient contact to wear a surgical mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  16. Universal Mask Usage for Reduction of Respiratory Viral Infections After Stem Cell Transplant: A Prospective Trial

    PubMed Central

    Sung, Anthony D.; Sung, Julia A. M.; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M.; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J.; Horwitz, Mitchell E.

    2016-01-01

    Background. Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. Methods. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010–2014) compared with the premask period (2003–2009). Results. RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P < .001). Significant decreases occurred after both allogeneic (64/378 [16.9%] to 24/289 [8.3%], P = .001) and autologous (31/542 [5.7%] to 16/622 [2.6%], P = .007) transplants. After adjusting for multiple covariates including season and year in a segmented longitudinal analysis, the decrease in RVIs remained significant, with risk of RVI of 0.4 in patients in the mask group compared with the premask group (0.19–0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P < .001). Conclusions. Requiring all individuals with direct patient contact to wear a surgical mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. PMID:27481873

  17. Masks for prevention of respiratory viruses on the BMT unit: results of a quality initiative.

    PubMed

    Sokol, Kelsey A; De la Vega-Diaz, Imelda; Edmondson-Martin, Kathleen; Kim, Sara; Tindle, Sharon; Wallach, Fran; Steinberg, Amir

    2016-12-01

    Respiratory viral infections (RVI) cause significant morbidity and mortality in hospitalized oncology patients. These viruses are easily spread from asymptomatic and/or symptomatic healthcare workers and visitors to immunocompromised patients, and literature review of facemasks for prevention of infection revealed mixed results. The Bone Marrow Transplant (BMT) Quality Assurance (QA) Committee at Mount Sinai began a surgical mask initiative on the BMT unit. The purpose of our initiative was to assess the impact of surgical mask implementation for healthcare workers and visitors on nosocomial RVI in all patients hospitalized on the BMT unit. We hypothesized that implementing surgical masks would reduce the number of hospital-acquired RVI. We performed a retrospective study involving all patients with malignancy hospitalized on the BMT unit for 4 years. During the latter 2 years, all healthcare workers and visitors were required to wear a surgical mask in every patient room on the BMT unit. Primary endpoint was incidence of RVI after implementation of surgical masks. The 2-year incidence of RVI in the pre-mask period was 14 out of a total of 15 001 patient days on the unit vs 2 out of 15 608 patient days after mask implementation. The difference in incidence of RVI within the two time intervals was noted to be statistically significant (P<.05, 2-proportion z-test). Our quality initiative demonstrated that surgical masks are an infection control modality that may provide benefit to oncology/BMT units by decreasing the risk for hospital-acquired RVI. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Alternating phase-shift mask and binary mask for 45-nm node and beyond: the impact on the mask error control

    NASA Astrophysics Data System (ADS)

    Kojima, Yosuke; Shirasaki, Masanori; Chiba, Kazuaki; Tanaka, Tsuyoshi; Inazuki, Yukio; Yoshikawa, Hiroki; Okazaki, Satoshi; Iwase, Kazuya; Ishikawa, Kiichi; Ozawa, Ken

    2007-05-01

    For 45 nm node and beyond, the alternating phase-shift mask (alt. PSM), one of the most expected resolution enhancement technologies (RET) because of its high image contrast and small mask error enhancement factor (MEEF), and the binary mask (BIM) attract attention. Reducing CD and registration errors and defect are their critical issues. As the solution, the new blank for alt. PSM and BIM is developed. The top film of new blank is thin Cr, and the antireflection film and shielding film composed of MoSi are deposited under the Cr film. The mask CD performance is evaluated for through pitch, CD linearity, CD uniformity, global loading, resolution and pattern fidelity, and the blank performance is evaluated for optical density, reflectivity, sheet resistance, flatness and defect level. It is found that the performance of new blank is equal to or better than that of conventional blank in all items. The mask CD performance shows significant improvement. The lithography performance of new blank is confirmed by wafer printing and AIMS measurement. The full dry type alt. PSM has been used as test plate, and the test results show that new blank can almost meet the specifications of pi-0 CD difference, CD uniformity and process margin for 45 nm node. Additionally, the new blank shows the better pattern fidelity than that of conventional blank on wafer. AIMS results are almost same as wafer results except for the narrowest pattern. Considering the result above, this new blank can reduce the mask error factors of alt. PSM and BIM for 45 nm node and beyond.

  19. Effects of baking-soda-containing dentifrices on oral malodor.

    PubMed

    Brunette, D M

    1997-01-01

    Oral malodor, also known as bad breath or halitosis, is an extremely common problem. Bad breath can arise from many sources in the body, but most frequently is produced in the mouth by the action of gram-negative anaerobic bacteria on sulfur-containing proteinaceous substrates in the saliva, such as debris and plaque. The primary molecules responsible for oral malodor are volatile sulfur compounds (VSC), such as hydrogen sulfide and methylmercaptan. Increased malodor production is related to greater bacterial numbers, reducing conditions, availability of protein substrates, and a pH above neutral. Bad breath is more common in the elderly, as well as those with unhygienic mouths, gingivitis, and periodontitis, but bad breath can also be found in some individuals who are periodontally healthy. The major source of oral malodor is the tongue. Approaches to controlling malodor have included masking, oral hygiene, antibacterial agents, conversion of VSC to nonodorous forms, oxidizing agents, and traditional approaches, including the use of backing soda. Results of controlled double-blind crossover studies, using both organoleptic (sensory) and gas chromatographic analysis of mouth air VSC, indicate that two dentifrices with high baking-soda concentrations, Arm & Hammer Dental Care and Arm & Hammer PeroxiCare, reduce oral malodor.

  20. Therapeutic Use of Cannabis in Inflammatory Bowel Disease

    PubMed Central

    Katz, Seymour

    2016-01-01

    The marijuana plant Cannabis sativa and its derivatives, cannabinoids, have grown increasingly popular as a potential therapy for inflammatory bowel disease (IBD). Studies have shown that modulation of the endocannabinoid system, which regulates various functions in the body and has been shown to play a key role in the pathogenesis of IBD, has a therapeutic effect in mouse colitis. Epidemiologic data and human therapy studies reveal a possible role for cannabinoids in the symptomatic treatment of IBD, although it has yet to be determined in human populations whether cannabinoids have therapeutic anti-inflammatory effects in IBD or are simply masking its many debilitating symptoms. Large, double-blind, randomized, placebo-controlled trials using serial inflammatory markers, biopsy findings, and endoscopic disease severity to demonstrate objective improvement in IBD are necessary before cannabis can be empirically accepted and recommended as an IBD treatment option. Questions concerning its safety profile and adverse effects prompt the need for further research, particularly in regard to dosing and route of administration to maximize benefits and limit potential harms. Cannabis use should be reserved for symptomatic control in patients with severe IBD refractory to the currently available standard-of-care and complementary and alternative medicines. PMID:28035196

  1. Full-chip level MEEF analysis using model based lithography verification

    NASA Astrophysics Data System (ADS)

    Kim, Juhwan; Wang, Lantian; Zhang, Daniel; Tang, Zongwu

    2005-11-01

    MEEF (Mask Error Enhancement Factor) has become a critical factor in CD uniformity control since optical lithography process moved to sub-resolution era. A lot of studies have been done by quantifying the impact of the mask CD (Critical Dimension) errors on the wafer CD errors1-2. However, the benefits from those studies were restricted only to small pattern areas of the full-chip data due to long simulation time. As fast turn around time can be achieved for the complicated verifications on very large data by linearly scalable distributed processing technology, model-based lithography verification becomes feasible for various types of applications such as post mask synthesis data sign off for mask tape out in production and lithography process development with full-chip data3,4,5. In this study, we introduced two useful methodologies for the full-chip level verification of mask error impact on wafer lithography patterning process. One methodology is to check MEEF distribution in addition to CD distribution through process window, which can be used for RET/OPC optimization at R&D stage. The other is to check mask error sensitivity on potential pinch and bridge hotspots through lithography process variation, where the outputs can be passed on to Mask CD metrology to add CD measurements on those hotspot locations. Two different OPC data were compared using the two methodologies in this study.

  2. Structural colour printing from a reusable generic nanosubstrate masked for the target image

    NASA Astrophysics Data System (ADS)

    Rezaei, M.; Jiang, H.; Kaminska, B.

    2016-02-01

    Structural colour printing has advantages over traditional pigment-based colour printing. However, the high fabrication cost has hindered its applications in printing large-area images because each image requires patterning structural pixels in nanoscale resolution. In this work, we present a novel strategy to print structural colour images from a pixelated substrate which is called a nanosubstrate. The nanosubstrate is fabricated only once using nanofabrication tools and can be reused for printing a large quantity of structural colour images. It contains closely packed arrays of nanostructures from which red, green, blue and infrared structural pixels can be imprinted. To print a target colour image, the nanosubstrate is first covered with a mask layer to block all the structural pixels. The mask layer is subsequently patterned according to the target colour image to make apertures of controllable sizes on top of the wanted primary colour pixels. The masked nanosubstrate is then used as a stamp to imprint the colour image onto a separate substrate surface using nanoimprint lithography. Different visual colours are achieved by properly mixing the red, green and blue primary colours into appropriate ratios controlled by the aperture sizes on the patterned mask layer. Such a strategy significantly reduces the cost and complexity of printing a structural colour image from lengthy nanoscale patterning into high throughput micro-patterning and makes it possible to apply structural colour printing in personalized security features and data storage. In this paper, nanocone array grating pixels were used as the structural pixels and the nanosubstrate contains structures to imprint the nanocone arrays. Laser lithography was implemented to pattern the mask layer with submicron resolution. The optical properties of the nanocone array gratings are studied in detail. Multiple printed structural colour images with embedded covert information are demonstrated.

  3. Mask data processing in the era of multibeam writers

    NASA Astrophysics Data System (ADS)

    Abboud, Frank E.; Asturias, Michael; Chandramouli, Maesh; Tezuka, Yoshihiro

    2014-10-01

    Mask writers' architectures have evolved through the years in response to ever tightening requirements for better resolution, tighter feature placement, improved CD control, and tolerable write time. The unprecedented extension of optical lithography and the myriad of Resolution Enhancement Techniques have tasked current mask writers with ever increasing shot count and higher dose, and therefore, increasing write time. Once again, we see the need for a transition to a new type of mask writer based on massively parallel architecture. These platforms offer a step function improvement in both dose and the ability to process massive amounts of data. The higher dose and almost unlimited appetite for edge corrections open new windows of opportunity to further push the envelope. These architectures are also naturally capable of producing curvilinear shapes, making the need to approximate a curve with multiple Manhattan shapes unnecessary.

  4. HCIT Contrast Performance Sensitivity Studies: Simulation Versus Experiment

    NASA Technical Reports Server (NTRS)

    Sidick, Erkin; Shaklan, Stuart; Krist, John; Cady, Eric J.; Kern, Brian; Balasubramanian, Kunjithapatham

    2013-01-01

    Using NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory, we have experimentally investigated the sensitivity of dark hole contrast in a Lyot coronagraph for the following factors: 1) Lateral and longitudinal translation of an occulting mask; 2) An opaque spot on the occulting mask; 3) Sizes of the controlled dark hole area. Also, we compared the measured results with simulations obtained using both MACOS (Modeling and Analysis for Controlled Optical Systems) and PROPER optical analysis programs with full three-dimensional near-field diffraction analysis to model HCIT's optical train and coronagraph.

  5. Effect of Otitis Media with Effusion on Comodulation Masking Release in Children.

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Grose, John H.

    1994-01-01

    This study investigated comodulation masking release (CMR) in 42 children (ages 5 to 10) with a history of otitis media with effusion (OME) and 19 control children with no history of ear disease. Results indicated that monotic CMRs were reduced in children with hearing loss due to OME and these CMRs remained abnormally small for several months.…

  6. Preventing facial pressure ulcers in patients under non-invasive mechanical ventilation: a randomised control trial.

    PubMed

    Otero, D Peña; Domínguez, D Vazquez; Fernández, L Hernanz; Magariño, A Santano; González, V Jimenez; Klepzing, J V García; Montesinos, J V Beneit

    2017-03-02

    To comparatively assess the efficacy of four different therapeutic strategies to prevent the development of facial pressure ulcers (FPUs) related to the use of non-invasive mechanical ventilation (NIV) with oro-nasal masks in critically ill hospitalised patients. This randomised control trial was performed at the high dependency unit in the University General Hospital Gregorio Marañón in Madrid, Spain. Overall, 152 patients with acute respiratory failure were recruited. All patients were hospitalised and received NIV through oro-nasal masks. The Norton tool was used to evaluate the general risk of developing pressure ulcers (PUs). Subjects were divided into four groups, each of them receiving a different treatment. Tissue assessment and preventive care were performed by a member of the research team. The incidence of FPUs was significantly lower in the group receiving a solution of hyperoxygenated fatty acids (HOFA) when compared with each of the other therapeutic strategies: direct mask (p=0.055), adhesive thin dressing (p=0.03) and adhesive foam dressing (p<0.001). The application of HOFA on the facial skin in contact with the oro-nasal masks showed the highest efficacy in the prevention of NIV-related FPUs.

  7. Airway difficulty in Mallampati 'class zero' patients: a prospective double-blind observational study.

    PubMed

    Hegde, Harihar V; Prasad, Kothegala C; Bhat, Manjunath T; Hegde, Jyothirmay S; Santhosh Mysore, C b; Yaliwal, Vijay G; Raghavendra Rao, P

    2012-07-01

    Assessment of Mallampati class is an integral part of preoperative airway evaluation. Increasing Mallampati class is known to be associated with greater difficulty with intubation, but some cases of airway difficulty in Mallampati 'class zero' patients have been reported. We undertook this study to evaluate intubation difficulty and to correlate this with indirect laryngoscopy findings in Mallampati class zero patients. The incidence of Mallampati class zero airway in Indian patients and the difficulty in mask ventilation were also evaluated. Prospective double-blind observational study. A tertiary care medical college hospital in Karnataka, India. September 2010 to April 2011. Patients of either sex, 18 years and older, presenting for preanaesthetic examination for elective surgery were evaluated. All patients with Mallampati class zero airway undergoing general anaesthesia with tracheal intubation were included. Exclusion criteria were upper airway disorder, unstable cervical spine, increased risk for aspiration, ischaemic heart disease, increased intracranial pressure, respiratory distress, those unable to sit upright, or infected with hepatitis B, hepatitis C, HIV or pulmonary tuberculosis, or requiring emergency surgery. All underwent indirect laryngoscopy performed by the otorhinolaryngologist and subsequently, direct laryngoscopy performed by the anaesthesiologist. Intubation difficulty was assessed by the Cormack & Lehane grades. Evaluation of intubation difficulty and correlation with indirect laryngoscopy findings in Mallampati class zero patients. Estimation of the incidence of Mallampati class zero airway in Indian patients and the difficulty in mask ventilation. Twenty women and thirteen men, aged 18-65 years, of Mallampati class zero were identified out of 1937 (incidence, 1.7%). The data of 27 patients were analysed. Two patients had 'difficult' mask ventilation. All had a 'predicted easy' airway on indirect laryngoscopy and 'easy' (Cormack & Lehane grade 1 or 2) tracheal intubation. Upon direct laryngoscopy, the epiglottis was described as 'large' in 10 (37%) patients. A Mallampati class zero per se is not associated with difficult airway unless other airway characteristics contribute to the difficulty. Even though the epiglottis may be large and overhanging, it rarely causes airway difficulty in Mallampati class zero airway.

  8. Marching of the microlithography horses: electron, ion, and photon: past, present, and future

    NASA Astrophysics Data System (ADS)

    Lin, Burn J.

    2007-03-01

    Microlithography patterning employs one of three media; electron, ion, and photon. They are in a way like horses, racing towards the mainstream. Some horses such as electrons run fast but repel each other. Ion beams behave like electron beams but are less developed. The photon beam is the undisputed workhorse, taking microlithography from the 5-μm minimum feature size to 32-nm half pitch. This paper examines the history of microlithography in pattern generation, proximity printing, and projection printing, then identifies the strong and weak points of each technology. In addition to ion-beam and e-beam lithography, the coverage of optical lithography spans the wavelength from 436 to 13.5 nm. Our learning from history helps us prevent mistakes in the future. In almost all cases, making or using the mask presents one of the limiting problems, no matter the type of beams or the replication method. Only the maskless method relieves us from mask-related problems. A way to overcome the low throughput handicap of maskless systems is to use multiple e-beam direct writing, whose imaging lens can be economically and compactly fabricated using MEMS techniques. In a way, the history of microlithography parallels that of aviation. Proximity printing is like the Wright-Brothers' plane; 1X projection printing, single-engine propeller plane with unitized body; reduction step-and-repeat projection printing, multi-engine commercial airliner; scanners, jet airliners. Optical lithography has improved in many ways than just increasing NA and reducing wavelength just as the commercial airliners improving in many other areas than just the speed. The SST increased the speed of airliners by more than a factor of two just as optical resolution doubled with double exposures. EUV lithography with the wavelength reduced by an order of magnitude is similar to the space shuttle increasing its speed to more than 10 times that of the SST. Multiple-beam direct write systems are like helicopters. They do not need airports(masks) but we need a lot of beams to carry the same payload.

  9. Zone routing in a torus network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Dong; Heidelberger, Philip; Kumar, Sameer

    A system for routing data in a network comprising a network logic device at a sending node for determining a path between the sending node and a receiving node, wherein the network logic device sets one or more selection bits and one or more hint bits within the data packet, a control register for storing one or more masks, wherein the network logic device uses the one or more selection bits to select a mask from the control register and the network logic device applies the selected mask to the hint bits to restrict routing of the data packet tomore » one or more routing directions for the data packet within the network and selects one of the restricted routing directions from the one or more routing directions and sends the data packet along a link in the selected routing direction toward the receiving node.« less

  10. The pilus usher controls protein interactions via domain masking and is functional as an oligomer.

    PubMed

    Werneburg, Glenn T; Henderson, Nadine S; Portnoy, Erica B; Sarowar, Samema; Hultgren, Scott J; Li, Huilin; Thanassi, David G

    2015-07-01

    The chaperone-usher (CU) pathway assembles organelles termed pili or fimbriae in Gram-negative bacteria. Type 1 pili expressed by uropathogenic Escherichia coli are prototypical structures assembled by the CU pathway. Biogenesis of pili by the CU pathway requires a periplasmic chaperone and an outer-membrane protein termed the usher (FimD). We show that the FimD C-terminal domains provide the high-affinity substrate-binding site but that these domains are masked in the resting usher. Domain masking requires the FimD plug domain, which serves as a switch controlling usher activation. We demonstrate that usher molecules can act in trans for pilus biogenesis, providing conclusive evidence for a functional usher oligomer. These results reveal mechanisms by which molecular machines such as the usher regulate and harness protein-protein interactions and suggest that ushers may interact in a cooperative manner during pilus assembly in bacteria.

  11. The Pilus Usher Controls Protein Interactions via Domain Masking and is Functional as an Oligomer

    PubMed Central

    Werneburg, Glenn T.; Henderson, Nadine S.; Portnoy, Erica B.; Sarowar, Samema; Hultgren, Scott J.; Li, Huilin; Thanassi, David G.

    2015-01-01

    The chaperone-usher (CU) pathway assembles organelles termed pili or fimbriae in Gram-negative bacteria. Type 1 pili expressed by uropathogenic Escherichia coli are prototypical structures assembled by the CU pathway. Biogenesis of pili by the CU pathway requires a periplasmic chaperone and an outer membrane protein termed the usher (FimD). We show that the FimD C-terminal domains provide the high-affinity substrate binding site, but that these domains are masked in the resting usher. Domain masking requires the FimD plug domain, which serves as a switch controlling usher activation. We demonstrate that usher molecules can act in trans for pilus biogenesis, providing conclusive evidence for a functional usher oligomer. These results reveal mechanisms by which molecular machines such as the usher regulate and harness protein-protein interactions, and suggest that ushers may interact in a cooperative manner during pilus assembly in bacteria. PMID:26052892

  12. Development of binary image masks for TPF-C and ground-based AO coronagraphs

    NASA Astrophysics Data System (ADS)

    Ge, Jian; Crepp, Justin; Vanden Heuvel, Andrew; Miller, Shane; McDavitt, Dan; Kravchenko, Ivan; Kuchner, Marc

    2006-06-01

    We report progress on the development of precision binary notch-filter focal plane coronagraphic masks for directly imaging Earth-like planets at visible wavelengths with the Terrestrial Planet Finder Coronagraph (TPF-C), and substellar companions at near infrared wavelengths from the ground with coronagraphs coupled to high-order adaptive optics (AO) systems. Our recent theoretical studies show that 8th-order image masks (Kuchner, Crepp & Ge 2005, KCG05) are capable of achieving unlimited dynamic range in an ideal optical system, while simultaneously remaining relatively insensitive to low-spatial-frequency optical aberrations, such as tip/tilt errors, defocus, coma, astigmatism, etc. These features offer a suite of advantages for the TPF-C by relaxing many control and stability requirements, and can also provide resistance to common practical problems associated with ground-based observations; for example, telescope flexure and low-order errors left uncorrected by the AO system due to wavefront sensor-deformable mirror lag time can leak light at significant levels. Our recent lab experiments show that prototype image masks can generate contrast levels on the order of 2x10 -6 at 3 λ/D and 6x10 -7 at 10 λ/D without deformable mirror correction using monochromatic light (Crepp et al. 2006), and that this contrast is limited primarily by light scattered by imperfections in the optics and extra diffraction created by mask construction errors. These experiments also indicate that the tilt and defocus sensitivities of high-order masks follow the theoretical predictions of Shaklan and Green 2005. In this paper, we discuss these topics as well as review our progress on developing techniques for fabricating a new series of image masks that are "free-standing", as such construction designs may alleviate some of the (mostly chromatic) problems associated with masks that rely on glass substrates for mechanical support. Finally, results obtained from our AO coronagraph simulations are provided in the last section. In particular, we find that: (i) apodized masks provide deeper contrast than hard-edge masks when the image quality exceeds 80% Strehl ratio (SR), (ii) above 90% SR, 4th-order band-limited masks provide higher off-axis throughput than Gaussian masks when generating comparable contrast levels, and (iii) below ~90% SR, hard-edge masks may be better suited for high contrast imaging, since they are less susceptible to tip/tilt alignment errors.

  13. [Reduction of pressure sores during prone positioning of ventilated intensive care patients by the prone-head support system: a pilot study].

    PubMed

    Prebio, Michael; Katz-Papatheophilou, Elfriede; Heindl, Werner; Gelbmann, Herbert; Burghuber, Otto C

    2005-02-01

    Prone positioning in patients with adult respiratory distress syndrome is a well-known method to improve oxygenation. The aim of our study was to evaluate a new device for prone positioning, the prone-head support system (PHS system), with regard to reduction of cutaneous pressure sores. In a pilot study we randomized 8 patients with ARDS in two groups: 180 degrees standard prone positioning (group without mask) and prone positioning with the PHS system (group with mask). The PHS system consists of a facemask support, which is connected to an adapted air suspension bed. The patients of both groups were intermittently proned for several days. We evaluated the pressure sores on head and neck before turning the patients prone for the first time and after each period of prone positioning. We documented the quantity, the size, the type and the localization of the pressure sores. There was no significant difference in the mean duration of prone positioning (27.1+/-14.7 hours in the group with mask versus 24.5+/-18.7 h in the group without mask). In the group with mask there were 1.5+/-0.8 new pressure sores by each proning, whereas in the group without mask there were 2.37+/-1.6 new pressure sores, which was lower, but not significantly. The overall area of pressure sores (798 mm2 versus 3184 mm2, p=0.004), the area of pressure sores per patient (199.5+/-104.7 mm2 versus 796+/-478 mm2, p=0.03) and the increase of the area of pressure sores per proning (79.8+/-52.0 mm2 versus 398.0+/-214.3 mm2, p=0.004) were significantly lower in the group with mask in comparison to the group without mask. The lips were the most effected localization in both groups. The pressure sores in the group with mask were less severe and showed a homogenous distribution in comparison to the group without mask. Blisters dominated in the group with mask in comparison to erosions, necrosis and ulcers in the group without mask. The PHS system with its face mask is able to reduce the extent and the severity of pressure sores in patients ventilated in prone position. Controlled randomized studies with large study populations seem justified.

  14. Mask_explorer: A tool for exploring brain masks in fMRI group analysis.

    PubMed

    Gajdoš, Martin; Mikl, Michal; Mareček, Radek

    2016-10-01

    Functional magnetic resonance imaging (fMRI) studies of the human brain are appearing in increasing numbers, providing interesting information about this complex system. Unique information about healthy and diseased brains is inferred using many types of experiments and analyses. In order to obtain reliable information, it is necessary to conduct consistent experiments with large samples of subjects and to involve statistical methods to confirm or reject any tested hypotheses. Group analysis is performed for all voxels within a group mask, i.e. a common space where all of the involved subjects contribute information. To our knowledge, a user-friendly interface with the ability to visualize subject-specific details in a common analysis space did not yet exist. The purpose of our work is to develop and present such interface. Several pitfalls have to be avoided while preparing fMRI data for group analysis. One such pitfall is spurious non-detection, caused by inferring conclusions in the volume of a group mask that has been corrupted due to a preprocessing failure. We describe a MATLAB toolbox, called the mask_explorer, designed for prevention of this pitfall. The mask_explorer uses a graphical user interface, enables a user-friendly exploration of subject masks and is freely available. It is able to compute subject masks from raw data and create lists of subjects with potentially problematic data. It runs under MATLAB with the widely used SPM toolbox. Moreover, we present several practical examples where the mask_explorer is usefully applied. The mask_explorer is designed to quickly control the quality of the group fMRI analysis volume and to identify specific failures related to preprocessing steps and acquisition. It helps researchers detect subjects with potentially problematic data and consequently enables inspection of the data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Data sharing system for lithography APC

    NASA Astrophysics Data System (ADS)

    Kawamura, Eiichi; Teranishi, Yoshiharu; Shimabara, Masanori

    2007-03-01

    We have developed a simple and cost-effective data sharing system between fabs for lithography advanced process control (APC). Lithography APC requires process flow, inter-layer information, history information, mask information and so on. So, inter-APC data sharing system has become necessary when lots are to be processed in multiple fabs (usually two fabs). The development cost and maintenance cost also have to be taken into account. The system handles minimum information necessary to make trend prediction for the lots. Three types of data have to be shared for precise trend prediction. First one is device information of the lots, e.g., process flow of the device and inter-layer information. Second one is mask information from mask suppliers, e.g., pattern characteristics and pattern widths. Last one is history data of the lots. Device information is electronic file and easy to handle. The electronic file is common between APCs and uploaded into the database. As for mask information sharing, mask information described in common format is obtained via Wide Area Network (WAN) from mask-vender will be stored in the mask-information data server. This information is periodically transferred to one specific lithography-APC server and compiled into the database. This lithography-APC server periodically delivers the mask-information to every other lithography-APC server. Process-history data sharing system mainly consists of function of delivering process-history data. In shipping production lots to another fab, the product-related process-history data is delivered by the lithography-APC server from the shipping site. We have confirmed the function and effectiveness of data sharing systems.

  16. Schizophrenia affects speech-induced functional connectivity of the superior temporal gyrus under cocktail-party listening conditions.

    PubMed

    Li, Juanhua; Wu, Chao; Zheng, Yingjun; Li, Ruikeng; Li, Xuanzi; She, Shenglin; Wu, Haibo; Peng, Hongjun; Ning, Yuping; Li, Liang

    2017-09-17

    The superior temporal gyrus (STG) is involved in speech recognition against informational masking under cocktail-party-listening conditions. Compared to healthy listeners, people with schizophrenia perform worse in speech recognition under informational speech-on-speech masking conditions. It is not clear whether the schizophrenia-related vulnerability to informational masking is associated with certain changes in FC of the STG with some critical brain regions. Using sparse-sampling fMRI design, this study investigated the differences between people with schizophrenia and healthy controls in FC of the STG for target-speech listening against informational speech-on-speech masking, when a listening condition with either perceived spatial separation (PSS, with a spatial release of informational masking) or perceived spatial co-location (PSC, without the spatial release) between target speech and masking speech was introduced. The results showed that in healthy participants, but not participants with schizophrenia, the contrast of either the PSS or PSC condition against the masker-only condition induced an enhancement of functional connectivity (FC) of the STG with the left superior parietal lobule and the right precuneus. Compared to healthy participants, participants with schizophrenia showed declined FC of the STG with the bilateral precuneus, right SPL, and right supplementary motor area. Thus, FC of the STG with the parietal areas is normally involved in speech listening against informational masking under either the PSS or PSC conditions, and declined FC of the STG in people with schizophrenia with the parietal areas may be associated with the increased vulnerability to informational masking. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. Time course of dichoptic masking in normals and suppression in amblyopes.

    PubMed

    Zhou, Jiawei; McNeal, Suzanne; Babu, Raiju J; Baker, Daniel H; Bobier, William R; Hess, Robert F

    2014-04-17

    To better understand the relationship between dichoptic masking in normal vision and suppression in amblyopia we address three questions: First, what is the time course of dichoptic masking in normals and amblyopes? Second, is interocular suppression low-pass or band-pass in its spatial dependence? And third, in the above two regards, is dichoptic masking in normals different from amblyopic suppression? We measured the dependence of dichoptic masking in normal controls and amblyopes on the temporal duration of presentation under three conditions; monocular (the nontested eye-i.e., dominant eye of normals or nonamblyopic eye of amblyopes, being patched), dichoptic-luminance (the nontested eye seeing a mean luminance-i.e., a DC component) and dichoptic-contrast (the nontested eye seeing high-contrast visual noise). The subject had to detect a letter in the other eye, the contrast of which was varied. We found that threshold elevation relative to the patched condition occurred in both normals and amblyopes when the nontested eye saw either 1/f or band-pass filtered noise, but not just mean luminance (i.e., there was no masking from the DC component that corresponds to a channel responsive to a spatial frequency of 0 cyc/deg); longer presentation of the target (corresponding to lower temporal frequencies) produced greater threshold elevation. Dichoptic masking exhibits similar properties in both subject groups, being low-pass temporally and band-pass spatially, so that masking was greatest at the longest presentation durations and was not greatly affected by mean luminance in the nontested eye. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Rat Palatability Study for Taste Assessment of Caffeine Citrate Formulation Prepared via Hot-Melt Extrusion Technology

    PubMed Central

    Tiwari, Roshan V.; Polk, Ashley N.; Patil, Hemlata; Ye, Xingyou; Pimparade, Manjeet B.; Repka, Michael A.

    2017-01-01

    Developing a pediatric oral formulation with an age-appropriate dosage form and taste masking of naturally bitter active pharmaceutical ingredients (APIs) are key challenges for formulation scientists. Several techniques are used for taste masking of bitter APIs to improve formulation palatability; however, not all the techniques are applicable to pediatric dosage forms because of the limitations on the kind and concentration of the excipients that can be used. Hot-melt extrusion (HME) technology is used successfully for taste masking of bitter APIs, and overcomes some of the limitations of the existing taste masking techniques. Likewise, analytical taste assessment is an important quality control parameter evaluated by several in vivo and in vitro methods, such as the human taste panel, electrophysiological methods, electronic sensor, and animal preference tests to aid in selecting a taste-masked formulation. However, the most appropriate in-vivo method to assess the taste-masking efficacy of pediatric formulations remains unknown, because it is not known to what extent the human taste panel/electronic tongue can predict the palatability in the pediatric patients. The purpose of this study was to develop taste-masked caffeine citrate extrudates via HME, and to demonstrate the wide applicability of a single bottle-test rat model to record and compare the volume consumed of the taste-masked solutions to that of the pure API. Thus, this rat model can be considered as a low-cost alternative taste-assessment method to the most commonly used expensive human taste panel/electronic tongue method for pediatric formulations. PMID:26573158

  19. Assessment of molecular contamination in mask pod

    NASA Astrophysics Data System (ADS)

    Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.

    2008-04-01

    Context/ study Motivation: Contamination and especially Airbone Molecular Contamination (AMC) is a critical issue for mask material flow with a severe and fairly unpredictable risk of induced contamination and damages especially for 193 nm lithography. It is therefore essential to measure, to understand and then try to reduce AMC in mask environment. Mask material flow was studied in a global approach by a pool of European partners, especially within the frame of European MEDEA+ project, so called "MUSCLE". This paper deals with results and assessment of mask pod environment in term of molecular contamination in a first step, then in a second step preliminary studies to reduce mask pod influence and contamination due to material out gassing. Approach and techniques: A specific assessment of environmental / molecular contamination along the supply chain was performed by all partners. After previous work presented at EMLC 07, further studies were performed on real time contamination measurement pod at different sites locations (including Mask manufacturing site, blank manufacturing sites, IC fab). Studies were linked to the main critical issues: cleaning, storage, handling, materials and processes. Contamination measurement campaigns were carried out along the mask supply chain using specific Adixen analyzer in order to monitor in real time organic contaminants (ppb level) in mask pods. Key results would be presented: VOC, AMC and humidity level on different kinds of mask carriers, impact of basic cleaning on pod outgassing measurement (VOC, NH3), and process influence on pod contamination... In a second step, preliminary specific pod conditioning studies for better pod environment were performed based on Adixen vacuum process. Process influence had been experimentally measured in term of molecular outgassing from mask pods. Different AMC experimental characterization methods had been carried out leading to results on a wide range of organic and inorganic contaminants: by inline techniques based on Adixen humidity, also VOC and organic sensors, together by off-line techniques already used in the extensive previous mask pods benchmark (TD-GCMS & Ionic Chromatography). Humidity and VOC levels from mask carriers had shown significant reduction after Adixen pod conditioning process. Focus had been made on optimized vacuum step (for AMC) after particles carrier cleaning cycle. Based upon these key results new procedures, as well as guidelines for mask carrier cleaning optimization are proposed to improve pod contamination control. Summary results/next steps: This paper reports molecular contamination measurement campaigns performed by a pool of European partners along the mask supply chain. It allows us to investigate, identify and quantify critical molecular contamination in mask pod, as well as VOC and humidity, issues depending on locations, uses, and carrier's type. Preliminary studies highlight initial process solutions for pods conditioning that are being used for short term industrialization and further industrialized.

  20. Effects of fentanyl administration before induction of anesthesia and placement of the Laryngeal Mask Airway: a randomized, placebo-controlled trial.

    PubMed

    Joshi, Girish P; Kamali, Amin; Meng, Jin; Rosero, Eric; Gasanova, Irina

    2014-03-01

    To assess the effects of fentanyl administered before induction of anesthesia on movement and airway responses during desflurane anesthesia via the Laryngeal Mask Airway (LMA). Randomized, double-blinded, controlled trial. Tertiary-care academic center. 100 adult, ASA physical status 1, 2, and 3 patients undergoing ambulatory surgery. Patients were administered fentanyl 1 μg/kg (n=51) or saline (n=49) 3 to 5 minutes before induction with propofol 2-2.5 mg/kg intravenously (IV), followed by LMA placement. Anesthesia was maintained with desflurane titrated to a bispectral index (BIS) of 50-60 and 50% nitrous oxide in oxygen, and fentanyl 25 μg boluses were titrated to respiratory rate. Apnea occurrence and duration of manual ventilation, as well as frequency and severity of movement, coughing, breath holding, and laryngospasm were recorded. Two patients in each group were excluded from analysis. The fentanyl pretreatment group had a higher frequency of apnea (94% vs 64%; P=0.0003) and longer duration of manual ventilation (3 [interquartile range (IQR), 1.5-5] min vs 1 [0-1.5] min; P<0.0001) at induction. In contrast, the fentanyl pretreatment group had a lower frequency of movements (16% vs 51%;P=0.0001). The rates of intraoperative breath holding (6.1% vs 8.5%) and laryngospasm (2% vs 4.3%) in the two groups were similar. All subjects experiencing laryngospasm were smokers. Adjusting for smoking status did not affect the differences noted in apnea, duration of manual ventilation, or movement between groups; however, coughing occurrence was statistically higher in the placebo group (P=0.043). Preinduction fentanyl increased the frequency of apnea at induction and duration of manual ventilation, but reduced the frequency of movements. In addition, it reduced intraoperative coughing in smokers. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Regular Nanoscale Protein Patterns via Directed Adsorption through Self-Assembled DNA Origami Masks.

    PubMed

    Ramakrishnan, Saminathan; Subramaniam, Sivaraman; Stewart, A Francis; Grundmeier, Guido; Keller, Adrian

    2016-11-16

    DNA origami has become a widely used method for synthesizing well-defined nanostructures with promising applications in various areas of nanotechnology, biophysics, and medicine. Recently, the possibility to transfer the shape of single DNA origami nanostructures into different materials via molecular lithography approaches has received growing interest due to the great structural control provided by the DNA origami technique. Here, we use ordered monolayers of DNA origami nanostructures with internal cavities on mica surfaces as molecular lithography masks for the fabrication of regular protein patterns over large surface areas. Exposure of the masked sample surface to negatively charged proteins results in the directed adsorption of the proteins onto the exposed surface areas in the holes of the mask. By controlling the buffer and adsorption conditions, the protein coverage of the exposed areas can be varied from single proteins to densely packed monolayers. To demonstrate the versatility of this approach, regular nanopatterns of four different proteins are fabricated: the single-strand annealing proteins Redβ and Sak, the iron-storage protein ferritin, and the blood protein bovine serum albumin (BSA). We furthermore demonstrate the desorption of the DNA origami mask after directed protein adsorption, which may enable the fabrication of hierarchical patterns composed of different protein species. Because selectivity in adsorption is achieved by electrostatic interactions between the proteins and the exposed surface areas, this approach may enable also the large-scale patterning of other charged molecular species or even nanoparticles.

  2. Fabrication of large area Si cylindric drift detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, W.; Kraner, H.W.; Li, Z.

    1993-04-01

    Advanced Si drift detector, a large area cylindrical drift detector (CDD), processing steps, with the exception of the ion implantation, were carried out in the BNL class 100 cleanroom. The double-side planer process technique was developed for the fabrication of CDD. Important improvements of the double-side planer process in this fabrication are the introduction of Al implantation protection mask and the remaining of a 1000 Angstroms oxide layer in the p-window during the implantation. Another important design of the CDD is the structure called ``river,`` which ,allows the current generated on Si-SiO{sub 2} interface to ``flow`` into the guard anode,more » and thus can minimize the leakage current at the signed anode. The test result showed that most of the signal anodes have the leakage current about 0.3 nA/cm{sup 2} for the best detector.« less

  3. Junctionless Thin-Film Transistors Gated by an H₃PO₄-Incorporated Chitosan Proton Conductor.

    PubMed

    Liu, Huixuan; Xun, Damao

    2018-04-01

    We fabricated an H3PO4-incorporated chitosan proton conductor film that exhibited the electric double layer effect and showed a high specific capacitance of 4.42 μF/cm2. Transparent indium tin oxide thin-film transistors gated by H3PO4-incorporated chitosan films were fabricated by sputtering through a shadow mask. The operating voltage was as low as 1.2 V because of the high specific capacitance of the H3PO4-incorporated chitosan dielectrics. The junctionless transparent indium tin oxide thin film transistors exhibited good performance, including an estimated current on/off ratio and field-effect mobility of 1.2 × 106 and 6.63 cm2V-1s-1, respectively. These low-voltage thin-film electric-double-layer transistors gated by H3PO4-incorporated chitosan are promising for next generation battery-powered "see-through" portable sensors.

  4. Super-resolution photon-efficient imaging by nanometric double-helix point spread function localization of emitters (SPINDLE)

    PubMed Central

    Grover, Ginni; DeLuca, Keith; Quirin, Sean; DeLuca, Jennifer; Piestun, Rafael

    2012-01-01

    Super-resolution imaging with photo-activatable or photo-switchable probes is a promising tool in biological applications to reveal previously unresolved intra-cellular details with visible light. This field benefits from developments in the areas of molecular probes, optical systems, and computational post-processing of the data. The joint design of optics and reconstruction processes using double-helix point spread functions (DH-PSF) provides high resolution three-dimensional (3D) imaging over a long depth-of-field. We demonstrate for the first time a method integrating a Fisher information efficient DH-PSF design, a surface relief optical phase mask, and an optimal 3D localization estimator. 3D super-resolution imaging using photo-switchable dyes reveals the 3D microtubule network in mammalian cells with localization precision approaching the information theoretical limit over a depth of 1.2 µm. PMID:23187521

  5. LC and LD50 values of Bacillus thuringiensis Serovar japonensis strain buibui toxin to Oriental beetle and northern masked chafer larvae (Coleoptera: Scarabaeidae).

    PubMed

    Mashtoly, Tamer A; El-Zemaity, Mohamed El-Said; Hussien, Mohamed I; Alm, Steven R

    2009-10-01

    Bacillus thuringiensis serovar japonensis strain Buibui has the potential to be an important control agent for pest scarabs. Bioassays were designed to test B. t. japonensis against two of the major turf and ornamental scarab pests infesting turfgrasses and ornamentals and to serve as a basis for further tests against other scarab pests. LC and LD50 values of B. t. serovarjaponensis strain Buibui toxin and spores were determined by four different bioassays for the oriental beetle, Anomala orientalis (Waterhouse), and northern masked chafer, Cyclocephala borealis Arrow. Oriental beetle larvae were bioassayed in autoclaved and nonautoclaved soil from where they were collected (Kingston, RI [native]), in nonautoclaved soil from where the northern masked chafer larvae were collected (Groton, CT [foreign]), and per os. Northern masked chafer larvae were bioassayed in autoclaved and nonautoclaved soil from where they were collected (Groton, CT [native]), in nonautoclaved soil from where the oriental beetle larvae were collected (Kingston, RI [foreign]) and per os. LC50 values of 3.93 microg toxin/g autoclaved native soil, 1.80 microg toxin/g nonautoclaved native soil, and 0.42 microg toxin/g nonautoclaved foreign soil and an LD50 value of 0.41 microg per os were determined at 14 d forA. orientalis. LC50 values of 588.28 microg toxin/g autoclaved native soil, 155.10 microg toxin/g nonautoclaved native soil, 265.32 microg toxin/g nonautoclaved foreign soil, and LD50 of 5.21 microg per os were determined at 14 d (soils) and 10 d (per os) for C. borealis. There were significant differences in LC50 values for oriental beetles in autoclaved, nonautoclaved native soil and nonautoclaved foreign soil. There were significant differences in LCo values for northern masked chafers in autoclaved and nonautoclaved native soil. B. t. japonensis can be applied now for control of oriental beetles at rates that are economically competitive with synthetic chemicals. If we can determine the component of nonautoclaved soil that enhances the activity of toxin, it may be possible to lower the rates of toxin needed for control to more economical levels for more difficult to control species such as the northern masked chafer.

  6. Altered affective response in marijuana smokers: an FMRI study.

    PubMed

    Gruber, Staci A; Rogowska, Jadwiga; Yurgelun-Todd, Deborah A

    2009-11-01

    More than 94 million Americans have tried marijuana, and it remains the most widely used illicit drug in the nation. Investigations of the cognitive effects of marijuana report alterations in brain function during tasks requiring executive control, including inhibition and decision-making. Endogenous cannabinoids regulate a variety of emotional responses, including anxiety, mood control, and aggression; nevertheless, little is known about smokers' responses to affective stimuli. The anterior cingulate and amygdala play key roles in the inhibition of impulsive behavior and affective regulation, and studies using PET and fMRI have demonstrated changes within these regions in marijuana smokers. Given alterations in mood and perception often observed in smokers, we hypothesized altered fMRI patterns of response in 15 chronic heavy marijuana smokers relative to 15 non-marijuana smoking control subjects during the viewing of masked happy and fearful faces. Despite no between-group differences on clinical or demographic measures, smokers demonstrated a relative decrease in both anterior cingulate and amygdalar activity during masked affective stimuli compared to controls, who showed relative increases in activation within these regions during the viewing of masked faces. Findings indicate that chronic heavy marijuana smokers demonstrate altered activation of frontal and limbic systems while viewing masked faces, consistent with autoradiographic studies reporting high CB-1 receptor density in these regions. These data suggest differences in affective processing in chronic smokers, even when stimuli are presented below the level of conscious processing, and underscore the likelihood that marijuana smokers process emotional information differently from those who do not smoke, which may result in negative consequences.

  7. A masked negative self-esteem? Implicit and explicit self-esteem in patients with Narcissistic Personality Disorder.

    PubMed

    Marissen, Marlies A E; Brouwer, Marlies E; Hiemstra, Annemarie M F; Deen, Mathijs L; Franken, Ingmar H A

    2016-08-30

    The mask model of narcissism states that the narcissistic traits of patients with NPD are the result of a compensatory reaction to underlying ego fragility. This model assumes that high explicit self-esteem masks low implicit self-esteem. However, research on narcissism has predominantly focused on non-clinical participants and data derived from patients diagnosed with Narcissistic Personality Disorder (NPD) remain scarce. Therefore, the goal of the present study was to test the mask model hypothesis of narcissism among patients with NPD. Male patients with NPD were compared to patients with other PD's and healthy participants on implicit and explicit self-esteem. NPD patients did not differ in levels of explicit and implicit self-esteem compared to both the psychiatric and the healthy control group. Overall, the current study found no evidence in support of the mask model of narcissism among a clinical group. This implicates that it might not be relevant for clinicians to focus treatment of NPD on an underlying negative self-esteem. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Preparation of orally disintegrating tablets with taste-masking function: masking effect in granules prepared with correctives using the dry granulation method and evaluation of tablets prepared using the taste-masked granules.

    PubMed

    Kawano, Yayoi; Ito, Akihiko; Sasatsu, Masanaho; Machida, Yoshiharu

    2010-01-01

    We investigated several methods of taste masking in the preparation of orally disintegrating tablets (ODTs), using furosemide (FU) as a model drug. Four types of FU preparations were prepared: granules with maltitol (MA), granules with yogurt powder (YO), a physical mixture of FU and MA, and a physical mixture of FU and YO. All taste-masking granules were prepared using the dry granulation method. The taste of each type of preparation was evaluated. All four preparations markedly improved the taste of the FU tablets, but the mixing ratios of the correctives did not affect the masking effect. No difference in masking effect was found between MA and YO in the physical mixtures, but the masking effect in the granules with YO was superior to that of the granules with MA. Taste-masked FU tablets were prepared using the direct compression method; crystalline cellulose (Avicel PH-302) and mannitol were added as excipients at the mixing ratio of 1/1. All four types of tablets displayed sufficient hardness, but MA-containing tablets were harder than YO-containing tablets. The hardness of the tablets prepared from YO granules increased as the YO content increased. The most rapidly disintegrating tablets were those of YO granules prepared at a mixing ratio of FU/YO=1/1, which disintegrated within 20 s, followed by the tablets of MA granules prepared at a mixing ratio of FU/MA=1/1. The disintegration times of the tablets made from physical mixtures, in contrast, were longer than 200 s. Disintegration time lengthened as the mixing ratio of YO or MA increased. The hardness and disintegration time of these tablets could be controlled by varying the compression pressure. We found that YO is more useful than MA in masking unpleasant tastes and confirmed that orally disintegrating tablets with taste-masking function can be prepared using granules of YO prepared using the dry granulation method as a new corrective.

  9. Metal oxide multilayer hard mask system for 3D nanofabrication

    NASA Astrophysics Data System (ADS)

    Han, Zhongmei; Salmi, Emma; Vehkamäki, Marko; Leskelä, Markku; Ritala, Mikko

    2018-02-01

    We demonstrate the preparation and exploitation of multilayer metal oxide hard masks for lithography and 3D nanofabrication. Atomic layer deposition (ALD) and focused ion beam (FIB) technologies are applied for mask deposition and mask patterning, respectively. A combination of ALD and FIB was used and a patterning procedure was developed to avoid the ion beam defects commonly met when using FIB alone for microfabrication. ALD grown Al2O3/Ta2O5/Al2O3 thin film stacks were FIB milled with 30 keV gallium ions and chemically etched in 5% tetramethylammonium hydroxide at 50 °C. With metal evaporation, multilayers consisting of amorphous oxides Al2O3 and Ta2O5 can be tailored for use in 2D lift-off processing, in preparation of embedded sub-100 nm metal lines and for multilevel electrical contacts. Good pattern transfer was achieved by lift-off process from the 2D hard mask for micro- and nano-scaled fabrication. As a demonstration of the applicability of this method to 3D structures, self-supporting 3D Ta2O5 masks were made from a film stack on gold particles. Finally, thin film resistors were fabricated by utilizing controlled stiction of suspended Ta2O5 structures.

  10. Observation of EUVL mask using coherent EUV scatterometry microscope with high-harmonic-generation EUV source

    NASA Astrophysics Data System (ADS)

    Mamezaki, Daiki; Harada, Tetsuo; Nagata, Yutaka; Watanabe, Takeo

    2017-07-01

    In extreme ultraviolet (EUV) lithography, development of review tools for EUV mask pattern and phase defect at working wavelength of 13.5 nm is required. The EUV mask is composed of an absorber pattern (50 - 70 nm thick) and Mo/Si multilayer (280 nm thick) on a glass substrate. This mask pattern seems three-dimensional (3D) structure. This 3D structure would modulate EUV reflection phase, which would cause focus and pattern shifts. Thus, EUV phase imaging is important to evaluate this phase modulation. We have developed coherent EUV scatterometry microscope (CSM), which is a simple microscope without objective optics. EUV phase and intensity image are reconstructed with diffraction images by ptychography with coherent EUV illumination. The high-harmonic-generation (HHG) EUV source was employed for standalone CSM system. In this study, we updated HHG system of pump-laser reduction and gas-pressure control. Two types of EUV mask absorber patterns were observed. An 88-nm lines-and-spaces and a cross-line patterns were clearly reconstructed by ptychography. In addition, a natural defect with 2-μm diameter on the cross-line was well reconstructed. This demonstrated the high capability of the standalone CSM, which system will be used in the factories, such as mask shops and semiconductor fabrication plants.

  11. Randomized Controlled Crossover Trial Comparing the Impact of Sham or Intranasal Tear Neurostimulation on Conjunctival Goblet Cell Degranulation.

    PubMed

    Gumus, Koray; Schuetzle, Karri L; Pflugfelder, Stephen C

    2017-05-01

    The aim of the study was to investigate the effects of the Allergan Intranasal Tear Neurostimulator (ITN) on conjunctival goblet cell (GC) degranulation. A randomized, double-masked, placebo-controlled crossover trial. A total of 15 subjects (5 normal and 10 dry eye) were enrolled in a 3-visit study consisting of 1 screening and 2 separate randomized-masked ITN treatments (sham extranasal or intranasal). Tear meniscus height (TMH) was measured by anterior segment optical coherence tomography before and after applications. Impression cytology (IC) was taken from the bulbar conjunctiva of the right eye for periodic acid-Schiff staining and from the left eye for MUC5AC mucin immunostaining at baseline and after each treatment. The ratio of degranulated to nondegranulated GCs was measured as a marker of secretion. In all participants, both inferior bulbar (IB) and temporal bulbar (TB) cytology specimens stained for MUC5AC revealed a significantly higher ratio of degranulated to nondegranulated GCs after the ITN (IB: 2.28 ± 1.27 and TB: 1.81 ± 1.01) compared to baseline (IB: 0.56 ± 0.55, P = .015) (TB: 0.56 ± 0.32, P = .003) and extranasal sham application (IB: 0.37 ± 0.29, P = .001) (TB: 0.39 ± 0.33, P = .001). When the same analysis was repeated in the dry eye or control groups, the ratio was significantly higher after ITN than the baseline ratio and ratio after extranasal application in both groups (P < .05). Moreover, although control subjects had a higher ratio of degranulated to nondegranulated GCs at baseline (0.75 ± 0.52) compared with the dry eye group (0.41 ± 0.27), the ratio became slightly higher in dry eye (2.04 ± 1.12 vs 1.99 ± 1.21 in control) after the ITN application. There was no significant difference between the IB or TB conjunctiva locations in terms of the effectiveness of the ITN application on conjunctival goblet cell secretory response. These preliminary results document that the Allergan ITN can stimulate degranulation of goblet cells in the conjunctiva, which is a promising new approach for the management of dry eye. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  12. Umbilical vein oxytocin for the treatment of retained placenta (Release Study): a double-blind, randomised controlled trial.

    PubMed

    Weeks, Andrew D; Alia, Godfrey; Vernon, Gillian; Namayanja, Annette; Gosakan, Radhika; Majeed, Tayyaba; Hart, Anna; Jafri, Hussain; Nardin, Juan; Carroli, Guillermo; Fairlie, Fiona; Raashid, Yasmin; Mirembe, Florence; Alfirevic, Zarko

    2010-01-09

    Retained placenta is associated with post-partum haemorrhage. Meta-analysis has suggested that umbilical injection of oxytocin could increase placental expulsion without the need for a surgeon or anaesthetic. We assessed the effect of high-dose umbilical vein oxytocin as a treatment for retained placenta. In this double-blind, placebo-controlled trial, haemodynamically stable women with a retained placenta for more than 30 min were recruited from 13 sites in the UK, Uganda, and Pakistan. 577 women were randomly assigned by a computer-generated randomisation list stratified by centre to 30 mL saline containing either 50 IU oxytocin (n=292) or 5 mL water (n=285), which was injected into the placenta through an umbilical vein catheter. All trial participants, study workers, and data handlers were masked to individual allocations. The primary outcome was the need for manual removal of the placenta. Analysis was by intention to treat. This study is registered, number ISRCTN 13204258. The primary outcome was recorded for all participants. We detected no difference between the groups in the need for manual removal of placenta (oxytocin 179/292 [61.3%] vs placebo 177/285 [62.1%]; relative risk 0.98, 95% CI 0.87-1.12; p=0.84). The need for manual removal was higher in the UK (overall 250/361 [69%]) than in Uganda (90/190 [47%]) or Pakistan (16/26 [62%]). Adverse events did not differ between the two groups. Umbilical oxytocin has no clinically significant effect on the need for manual removal for women with retained placenta. WHO, WellBeing of Women, Pakistan Higher Education Commission. Copyright 2010 Elsevier Ltd. All rights reserved.

  13. Relevance of casual contact with peanut butter in children with peanut allergy.

    PubMed

    Simonte, Steven J; Ma, Songhui; Mofidi, Shideh; Sicherer, Scott H

    2003-07-01

    Casual skin contact or inhalation of peanut butter fumes is reported and feared to cause allergic reactions in highly sensitive children with peanut allergy but has not been systematically studied. We sought to determine the clinical relevance of exposure to peanut butter by means of inhalation and skin contact in children with peanut allergy. Children with significant peanut allergy (recent peanut-specific IgE antibody concentration >50 kIU/L or evidence of peanut-specific IgE antibody and one of the following: clinical anaphylaxis, a reported inhalation-contact reaction, or positive double-blind, placebo-controlled oral challenge result to peanut) underwent double-blind, placebo-controlled, randomized exposures to peanut butter by means of contact with intact skin (0.2 mL pressed flat for 1 minute) and inhalation (surface area of 6.3 square inches 12 inches from the face for 10 minutes). Placebo challenges were performed by using soy butter mixed with histamine (contact), and scent was masked with soy butter, tuna, and mint (inhalation). Thirty children underwent the challenges (median age, 7.7 years; median peanut IgE level, >100 kIU/L; 13 with prior history of contact and 11 with inhalation reactions). None experienced a systemic or respiratory reaction. Erythema (3 subjects), pruritus without erythema (5 subjects), and wheal-and-flare reactions (2 subjects) developed only at the site of skin contact with peanut butter. From this number of participants, it can be stated with 96% confidence that at least 90% of highly sensitive children with peanut allergy would not experience a systemic-respiratory reaction from casual exposure to peanut butter. Casual exposure to peanut butter is unlikely to elicit significant allergic reactions. The results cannot be generalized to larger exposures or to contact with peanut in other forms (flour and roasted peanuts).

  14. Sildenafil citrate as a medical expulsive therapy for distal ureteric stones: A randomised double-blind placebo-controlled study.

    PubMed

    Shokeir, Ahmed A; Tharwat, Mohamed A; Abolazm, Ahmed Elhussein; Harraz, Ahmed

    2016-03-01

    To study the effect of sildenafil citrate on spontaneous passage of distal ureteric stones (DUS). This was a randomised double-blinded placebo-controlled study of 100 patients with DUS. Inclusion criteria were: male, age 18-65 years, normal renal function, and a single radiopaque unilateral DUS of 5-10 mm. Patients were randomly allocated into two equal groups, one that received placebo and the other that received 50 mg sildenafil citrate once daily. Both investigators and patients were masked to the type of treatment. Patients self-administered the medication until spontaneous passage of the DUS. In patients where there was uncontrolled pain, fever, an increase in serum creatinine of >1.8 mg/dL, progressive hydronephrosis or no further progress after 4 weeks, a decision was taken for further treatment. In all, 47 and 49 patients were available for analysis in both the placebo and sildenafil citrate groups; respectively. Both groups were comparable for age and stone characteristics. Spontaneous expulsion occurred in 19 of 47 patients (40.4%) in the placebo group and in 33 of 49 (67.3%) in the sildenafil citrate group (P = 0.014). The mean time to stone expulsion was significantly shorter in the sildenafil citrate group (P < 0.001). A multivariable Cox proportional hazards model showed that receiving sildenafil citrate was the only independent factor that had a significant impact on stone passage with a hazard ratio of 2.7 (95% confidence interval 1.5-4.8; P < 0.001). Sildenafil citrate enhances spontaneous passage of 5-10 mm DUS.

  15. Do different perceptual task sets modulate electrophysiological correlates of masked visuomotor priming? Attention to shape and color put to the test.

    PubMed

    Zovko, Monika; Kiefer, Markus

    2013-02-01

    According to classical theories, automatic processes operate independently of attention. Recent evidence, however, shows that masked visuomotor priming, an example of an automatic process, depends on attention to visual form versus semantics. In a continuation of this approach, we probed feature-specific attention within the perceptual domain and tested in two event-related potential (ERP) studies whether masked visuomotor priming in a shape decision task specifically depends on attentional sensitization of visual pathways for shape in contrast to color. Prior to the masked priming procedure, a shape or a color decision task served to induce corresponding task sets. ERP analyses revealed visuomotor priming effects over the occipitoparietal scalp only after the shape, but not after the color induction task. Thus, top-down control coordinates automatic processing streams in congruency with higher-level goals even at a fine-grained level. Copyright © 2012 Society for Psychophysiological Research.

  16. The role of lines and corners of geometric figures in recognition performance.

    PubMed

    Shevelev, Igor A; Kamenkovich, Viktorina M; Sharaev, George A

    2003-01-01

    A relative role of lines and corners of images of outline geometric figures in recognition performance was studied psychophysically. Probability of correct response to the shape of the whole figure (control) and figures with lines or corners masked to a different extent was compared. Increase in the extent of masking resulted in a drop of recognition performance that was significantly lower for figures without corners, than for figures without part of their lines. The whole 3D figures were recognized better than 2D ones, whereas the opposite relations were observed under conditions of masking. Significant gender difference in a recognition performance was found: men recognize entire and partly masked figures better than women. Possible mechanisms of relatively better recognition of figures with corners than with lines are discussed in connection with finding of high sensitivity of many neurons in the primary visual cortex to line crossing and branching.

  17. Low cost solar array project cell and module formation research area: Process research of non-CZ silicon material

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Liquid diffusion masks and liquid applied dopants to replace the CVD Silox masking and gaseous diffusion operations specified for forming junctions in the Westinghouse baseline process sequence for producing solar cells from dendritic web silicon were investigated. The baseline diffusion masking and drive processes were compared with those involving direct liquid applications to the dendritic web silicon strips. Attempts were made to control the number of variables by subjecting dendritic web strips cut from a single web crystal to both types of operations. Data generated reinforced earlier conclusions that efficiency levels at least as high as those achieved with the baseline back junction formation process can be achieved using liquid diffusion masks and liquid dopants. The deliveries of dendritic web sheet material and solar cells specified by the current contract were made as scheduled.

  18. Interocular suppression in normal and amblyopic vision: spatio-temporal properties.

    PubMed

    Huang, Pi-Chun; Baker, Daniel H; Hess, Robert F

    2012-10-31

    We measured the properties of interocular suppression in strabismic amblyopes and compared these to dichoptic masking in binocularly normal observers. We used a dichoptic version of the well-established probed-sinewave paradigm that measured sensitivity to a brief target stimulus (one of four letters to be discriminated) in the amblyopic eye at different times relative to a suppression-inducing mask in the fixing eye. This was done using both sinusoidal steady state and transient approaches. The suppression-inducing masks were either modulations of luminance or contrast (full field, just overlaying the target, or just surrounding the target). Our results were interpreted using a descriptive model that included contrast gain control and spatio-temporal filtering prior to excitatory binocular combination. The suppression we measured, other than in magnitude, was not fundamentally different from normal dichoptic masking: lowpass spatio-temporal properties with similar contributions from both surround and overlay suppression.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crane, Cameron C.; Tao, Jing; Wang, Feng

    Controlling the deposition of exotic metals in the seeded growth of multi-metal nanostructures is challenging. This work describes a seeded growth method assisted by a mask for synthesis of segmented binary or ternary metal nanostructures. Silica is used as a mask to partially block the surface of a seed and a second metal is subsequently deposited on the exposed area, forming a bimetallic heterodimer. The initial demonstration was carried out on a Au seed, followed by deposition of Pd or Pt on the seed. It was found that Pd tends to spread out laterally on the seed while Pt inclinesmore » to grow vertically into branched topology on Au. Without removal of the SiO₂ mask, Pt could be further deposited on the unblocked Pd of the Pd-Au dimer to form a Pt-Pd-Au trimer. The mask-assisted seeded growth provides a general strategy to construct segmented metallic nanoarchitectures.« less

  20. An orbital angular momentum radio communication system optimized by intensity controlled masks effectively: Theoretical design and experimental verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Xinlu; Applied Optics Beijing Area Major Laboratory, Department of Physics, Beijing Normal University, Beijing 100875; Huang, Shanguo, E-mail: shghuang@bupt.edu.cn

    A system of generating and receiving orbital angular momentum (OAM) radio beams, which are collectively formed by two circular array antennas (CAAs) and effectively optimized by two intensity controlled masks, is proposed and experimentally investigated. The scheme is effective in blocking of the unwanted OAM modes and enhancing the power of received radio signals, which results in the capacity gain of system and extended transmission distance of the OAM radio beams. The operation principle of the intensity controlled masks, which can be regarded as both collimator and filter, is feasible and simple to realize. Numerical simulations of intensity and phasemore » distributions at each key cross-sectional plane of the radio beams demonstrate the collimated results. The experimental results match well with the theoretical analysis and the receive distance of the OAM radio beam at radio frequency (RF) 20 GHz is extended up to 200 times of the wavelength of the RF signals, the measured distance is 5 times of the original measured distance. The presented proof-of-concept experiment demonstrates the feasibility of the system.« less

  1. Control of odour nuisance in urban areas: the efficiency and social acceptance of the application of masking agents.

    PubMed

    Lazarova, Valentina; Abed, Brahim; Markovska, Gabriela; Dezenclos, Thierry; Amara, Aït

    2013-01-01

    This paper presents and discusses the results of the project named 'Jasmin' implemented in Algiers to control the strong odours of the river named Oued El Harrach, one of the largest rivers in the centre of the city. Pending the achievement of curative solutions, a temporary option for mitigation of nuisance odour by masking agents was implemented in the vicinity of the main bridges. The efficiency of this technology has been followed by means of an odour panel with the participation of representatives of all stakeholders. A sociological study by means of 1,000 questionnaires and face-to-face interviews of the local population demonstrated the benefits and the positive outcomes of the attenuation of odour nuisance: 70% of the surveyed population is satisfied or very satisfied with the application of masking agents and 96% of respondents support the continuation of the project. In terms of size and public access, the project Jasmin is a world-first demonstration of odour control in urban areas in developing countries.

  2. Digital Images and Human Vision

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Null, Cynthia H. (Technical Monitor)

    1997-01-01

    Processing of digital images destined for visual consumption raises many interesting questions regarding human visual sensitivity. This talk will survey some of these questions, including some that have been answered and some that have not. There will be an emphasis upon visual masking, and a distinction will be drawn between masking due to contrast gain control processes, and due to processes such as hypothesis testing, pattern recognition, and visual search.

  3. The effectiveness of robust RMCD control chart as outliers’ detector

    NASA Astrophysics Data System (ADS)

    Darmanto; Astutik, Suci

    2017-12-01

    A well-known control chart to monitor a multivariate process is Hotelling’s T 2 which its parameters are estimated classically, very sensitive and also marred by masking and swamping of outliers data effect. To overcome these situation, robust estimators are strongly recommended. One of robust estimators is re-weighted minimum covariance determinant (RMCD) which has robust characteristics as same as MCD. In this paper, the effectiveness term is accuracy of the RMCD control chart in detecting outliers as real outliers. In other word, how effectively this control chart can identify and remove masking and swamping effects of outliers. We assessed the effectiveness the robust control chart based on simulation by considering different scenarios: n sample sizes, proportion of outliers, number of p quality characteristics. We found that in some scenarios, this RMCD robust control chart works effectively.

  4. Illusionary delusions. Willingness to exercise self-control can mask effects of glucose on self-control performance in experimental paradigms that use identical self-control tasks.

    PubMed

    Chatzisarantis, Nikos L D; Hagger, Martin S

    2015-01-01

    The purpose of the present article is to highlight limitations of Lange and Eggert's methodology of using identical self-control tasks in testing effects of glucose on depletion of self-control resources and self-control performance. We suggest that when participants engage in two identical self-control tasks, cognitions developed during initial act of self-control may mask the effects of glucose on self-control performance by undermining willingness to exert effort during the second act of self-control. As a consequence, glucose may increase ability to exercise self-control but participants may not want to capitalize on this "ability advantage" because they are unwilling to exercise self-control. The present article concludes that researchers who test the glucose hypothesis in the context of a depletion paradigm should employ dissimilar acts of self-control and ensure that depleted participants are sufficiently motivated to exercise self-control. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  5. Impact of the flu mask regulation on health care personnel influenza vaccine acceptance rates.

    PubMed

    Edwards, Frances; Masick, Kevin D; Armellino, Donna

    2016-10-01

    Achieving high vaccination rates of health care personnel (HCP) is critical in preventing influenza transmission from HCP to patients and from patients to HCP; however, acceptance rates remain low. In 2013, New York State adopted the flu mask regulation, requiring unvaccinated HCP to wear a mask when in areas where patients are present. The purpose of this study assessed the impact of the flu mask regulation on the HCP influenza vaccination rate. A 13-question survey was distributed electronically and manually to the HCP to examine their knowledge of influenza transmission and the influenza vaccine and their personal vaccine acceptance history and perception about the use of the mask while working if not vaccinated. There were 1,905 respondents; 87% accepted the influenza vaccine, and 63% were first-time recipients who agreed the regulation influenced their vaccination decision. Of the respondents who declined the vaccine, 72% acknowledge HCP are at risk for transmitting influenza to patients, and 56% reported they did not receive enough information to make an educated decision. The flu mask protocol may have influenced HCP's choice to be vaccinated versus wearing a mask. The study findings supported that HCP may not have adequate knowledge on the morbidity and mortality associated with influenza. Regulatory agencies need to consider an alternative approach to increase HCP vaccination, such as mandating the influenza vaccine for HCP. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Development of Personalized Fitting Device With 3-Dimensional Solution for Prevention of NIV Oronasal Mask-Related Pressure Ulcers.

    PubMed

    Shikama, Maiko; Nakagami, Gojiro; Noguchi, Hiroshi; Mori, Taketoshi; Sanada, Hiromi

    2018-05-22

    Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. We conducted a randomized crossover experimental study of 20 healthy participants to study the use of this personalized fitting device between the face and an NIV mask designed with 3D solutions. The fitting device was not used under the NIV mask for the control. The outcome measures were the presence of blanchable erythema, standardized redness intensity, discomfort level, and contact pressure. The incidence of blanchable erythema and standardized redness intensity values were significantly lower for subjects who used the fitting device when worn for 30 min ( P < .001). The discomfort levels at the forehead, nasal bridge, and both cheeks, as well as leakage, were significantly reduced as well ( P = .008, P < .001, P = .001, P = .002, P = .001, P = .02, P < .001, P < .001, P < .001). Contact pressure at the nasal bridge, where pressure ulcers most frequently develop, was significantly decreased with the fitting device ( P < .001). Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort. Copyright © 2018 by Daedalus Enterprises.

  7. Process optimization for particle removal on blank chrome mask plates in preparation for resist application

    NASA Astrophysics Data System (ADS)

    Osborne, Stephen; Smith, Eryn; Woster, Eric; Pelayo, Anthony

    2002-03-01

    As integrated circuits require smaller lines to provide the memory and processing capability for tomorrow's marketplace, the photomask industry is adopting higher contrast resists to improve photomask lithography. Photomask yield for several high-contrast resist recipes may be improved by coating masks at the mask shop. When coating at a mask shop, an effective method is available that uses coat/bake cluster tools to ensure blanks are clean prior to coating. Many high-contrast resists are available, and some are more susceptible to time-dependent performance factors than conventional resists. One of these factors is the time between coating and writing. Although future methods may reduce the impact of this factor, one current trend is to reduce this time by coating plates at the mask shop just prior to writing. Establishing an effective process to clean blanks prior to coating is necessary for product quality control and is a new task that is critical for maskmakers who previously purchased mask plates but have decided to begin coating them within their facility. This paper provides a strategy and method to be used within coat/bake cluster tools to remove particle contamination from mask blanks. The process uses excimer-UV ionizing radiation and ozone to remove organic contaminants, and then uses a wet process combined with megasonic agitation, surfactant, and spin forces. Megasonic agitation with surfactant lifts up particles, while the convective outflow of water enhances centripetal shear without accumulating harmful charge.

  8. Thermal image analysis for detecting facemask leakage

    NASA Astrophysics Data System (ADS)

    Dowdall, Jonathan B.; Pavlidis, Ioannis T.; Levine, James

    2005-03-01

    Due to the modern advent of near ubiquitous accessibility to rapid international transportation the epidemiologic trends of highly communicable diseases can be devastating. With the recent emergence of diseases matching this pattern, such as Severe Acute Respiratory Syndrome (SARS), an area of overt concern has been the transmission of infection through respiratory droplets. Approved facemasks are typically effective physical barriers for preventing the spread of viruses through droplets, but breaches in a mask"s integrity can lead to an elevated risk of exposure and subsequent infection. Quality control mechanisms in place during the manufacturing process insure that masks are defect free when leaving the factory, but there remains little to detect damage caused by transportation or during usage. A system that could monitor masks in real-time while they were in use would facilitate a more secure environment for treatment and screening. To fulfill this necessity, we have devised a touchless method to detect mask breaches in real-time by utilizing the emissive properties of the mask in the thermal infrared spectrum. Specifically, we use a specialized thermal imaging system to detect minute air leakage in masks based on the principles of heat transfer and thermodynamics. The advantage of this passive modality is that thermal imaging does not require contact with the subject and can provide instant visualization and analysis. These capabilities can prove invaluable for protecting personnel in scenarios with elevated levels of transmission risk such as hospital clinics, border check points, and airports.

  9. Assisted suicide by oxygen deprivation with helium at a Swiss right-to-die organisation.

    PubMed

    Ogden, Russel D; Hamilton, William K; Whitcher, Charles

    2010-03-01

    In Switzerland, right-to-die organisations assist their members with suicide by lethal drugs, usually barbiturates. One organisation, Dignitas, has experimented with oxygen deprivation as an alternative to sodium pentobarbital. To analyse the process of assisted suicide by oxygen deprivation with helium and a common face mask and reservoir bag. This study examined four cases of assisted suicide by oxygen deprivation using helium delivered via a face mask. Videos of the deaths were provided by the Zurich police. Dignitas provided protocol and consent information. One man and three women were assisted to death by oxygen deprivation. There was wide variation in the time to unconsciousness and the time to death, probably due to the poor mask fit. Swiss law prevented attendants from effectively managing the face mask apparatus. Purposeless movements of the extremities were disconcerting for Dignitas attendants, who are accustomed to assisting suicide with barbiturates. None of the dying individuals attempted self-rescue. The dying process of oxygen deprivation with helium is potentially quick and appears painless. It also bypasses the prescribing role of physicians, effectively demedicalising assisted suicide. Oxygen deprivation with a face mask is not acceptable because leaks are difficult to control and it may not eliminate rebreathing. These factors will extend time to unconsciousness and time to death. A hood method could reduce the problem of mask fit. With a hood, a flow rate of helium sufficient to provide continuous washout of expired gases would remedy problems observed with the mask.

  10. Continuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.

    PubMed

    Chidini, Giovanna; Piastra, Marco; Marchesi, Tiziana; De Luca, Daniele; Napolitano, Luisa; Salvo, Ida; Wolfler, Andrea; Pelosi, Paolo; Damasco, Mirco; Conti, Giorgio; Calderini, Edoardo

    2015-04-01

    Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced ARF. In this multicenter randomized controlled trial, 30 infants with respiratory syncytial virus-induced ARF were randomized to receive CPAP by helmet (n = 17) or facial mask (n = 13). The primary endpoint was treatment failure rate (defined as due to intolerance or need for intubation). Secondary outcomes were CPAP application time, number of patients requiring sedation, and complications with each interface. Compared with the facial mask, CPAP by helmet had a lower treatment failure rate due to intolerance (3/17 [17%] vs 7/13 [54%], P = .009), and fewer infants required sedation (6/17 [35%] vs 13/13 [100%], P = .023); the intubation rates were similar. In successfully treated patients, CPAP resulted in better gas exchange and breathing pattern with both interfaces. No major complications due to the interfaces occurred, but CPAP by mask had higher rates of cutaneous sores and leaks. These findings confirm that CPAP delivered by helmet is better tolerated than CPAP delivered by facial mask and requires less sedation. In addition, it is safe to use and free from adverse events, even in a prolonged clinical setting. Copyright © 2015 by the American Academy of Pediatrics.

  11. Cross-orientation suppression in human visual cortex

    PubMed Central

    Heeger, David J.

    2011-01-01

    Cross-orientation suppression was measured in human primary visual cortex (V1) to test the normalization model. Subjects viewed vertical target gratings (of varying contrasts) with or without a superimposed horizontal mask grating (fixed contrast). We used functional magnetic resonance imaging (fMRI) to measure the activity in each of several hypothetical channels (corresponding to subpopulations of neurons) with different orientation tunings and fit these orientation-selective responses with the normalization model. For the V1 channel maximally tuned to the target orientation, responses increased with target contrast but were suppressed when the horizontal mask was added, evident as a shift in the contrast gain of this channel's responses. For the channel maximally tuned to the mask orientation, a constant baseline response was evoked for all target contrasts when the mask was absent; responses decreased with increasing target contrast when the mask was present. The normalization model provided a good fit to the contrast-response functions with and without the mask. In a control experiment, the target and mask presentations were temporally interleaved, and we found no shift in contrast gain, i.e., no evidence for suppression. We conclude that the normalization model can explain cross-orientation suppression in human visual cortex. The approach adopted here can be applied broadly to infer, simultaneously, the responses of several subpopulations of neurons in the human brain that span particular stimulus or feature spaces, and characterize their interactions. In addition, it allows us to investigate how stimuli are represented by the inferred activity of entire neural populations. PMID:21775720

  12. Emergence times and airway reactions in general laryngeal mask airway anesthesia: study protocol for a randomized controlled trial.

    PubMed

    Stevanovic, Ana; Rossaint, Rolf; Keszei, András P; Fritz, Harald; Fröba, Gebhard; Pühringer, Friedrich; Coburn, Mark

    2015-07-26

    The use of a laryngeal mask airway (LMA) in appropriate patients supports fast-track anesthesia with a lower incidence of postoperative airway-connected adverse events. Data on the most favorable anesthetic in this context, with the lowest rate of upper airway complications and fast emergence times, are controversial and limited. Desflurane seems to match these criteria best, but large randomized controlled trials (RCTs) with a standardized study protocol are lacking. Therefore, we aim to compare desflurane with other commonly used anesthetics, sevoflurane and propofol, in a sufficiently powered RCT. We hypothesize that desflurane is noninferior regarding the frequency of upper airway events and superior regarding the emergence times to sevoflurane and propofol. A total of 351 patients undergoing surgery with an LMA will be included in this prospective, randomized, double-blind controlled, multicenter clinical trial. The patients will be randomly assigned to the three treatment arms: desflurane (n = 117), sevoflurane (n = 117), and propofol (n = 117). The emergence time (time to state the date of birth) will be the primary endpoint of this study. The secondary endpoints include further emergence times, such as time to open eyes, to remove LMA, to respond to command and to state name. Additionally, we will determine the frequency of cough and laryngospasm, measured intraoperatively and at emergence. We will assess the postoperative recovery on the first postoperative day via the Postoperative Quality Recovery Scale. Despite increasing importance of cost-effective and safe anesthesia application, we lack proof for the most advantageous anesthetic agent, when an LMA is used. There are only a few RCTs comparing desflurane to other commonly used anesthetics (sevoflurane, propofol and isoflurane) in patients with LMA. These RCTs were conducted with small sample sizes, huge interstudy variability, and some also showed strong biases. The present multicenter RCT will provide results from a large sample size with a standardized study protocol and minimized bias, which is feasible in the clinical routine. Furthermore, we will expand our knowledge regarding the most favorable recovery on the first postoperative day, which impacts patients' comfort after surgery. EudraCT Identifier: 2014-003810-96, 5 September 2014 ClinicalTrials.gov: NCT02322502, December 2014.

  13. Designs and Materials for Better Coronagraph Occulting Masks

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatham

    2010-01-01

    New designs, and materials appropriate for such designs, are under investigation in an effort to develop coronagraph occulting masks having broad-band spectral characteristics superior to those currently employed. These designs and materials are applicable to all coronagraphs, both ground-based and spaceborne. This effort also offers potential benefits for the development of other optical masks and filters that are required (1) for precisely tailored spatial transmission profiles, (2) to be characterized by optical-density neutrality and phase neutrality (that is, to be characterized by constant optical density and constant phase over broad wavelength ranges), and/or (3) not to exhibit optical- density-dependent phase shifts. The need for this effort arises for the following reasons: Coronagraph occulting masks are required to impose, on beams of light transmitted through them, extremely precise control of amplitude and phase according to carefully designed transmission profiles. In the original application that gave rise to this effort, the concern has been to develop broad-band occulting masks for NASA s Terrestrial Planet Finder coronagraph. Until now, experimental samples of these masks have been made from high-energy-beam-sensitive (HEBS) glass, which becomes locally dark where irradiated with a high-energy electron beam, the amount of darkening depending on the electron-beam energy and dose. Precise mask profiles have been written on HEBS glass blanks by use of electron beams, and the masks have performed satisfactorily in monochromatic light. However, the optical-density and phase profiles of the HEBS masks vary significantly with wavelength; consequently, the HEBS masks perform unsatisfactorily in broad-band light. The key properties of materials to be used in coronagraph occulting masks are their extinction coefficients, their indices of refraction, and the variations of these parameters with wavelength. The effort thus far has included theoretical predictions of performances of masks that would be made from alternative materials chosen because the wavelength dependences of their extinction coefficients and their indices of refraction are such that that the optical-density and phase profiles of masks made from these materials can be expected to vary much less with wavelength than do those of masks made from HEBS glass. The alternative materials considered thus far include some elemental metals such as Pt and Ni, metal alloys such as Inconel, metal nitrides such as TiN, and dielectrics such as SiO2. A mask as now envisioned would include thin metal and dielectric films having stepped or smoothly varying thicknesses (see figure). The thicknesses would be chosen, taking account of the indices of refraction and extinction coefficients, to obtain an acceptably close approximation of the desired spatial transmittance profile with a flat phase profile

  14. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    PubMed

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.

  15. Effects of subliminally presented auditory suggestions of itching on scratching behavior.

    PubMed

    Mitchell, C W

    1995-02-01

    This study investigated effects of masked verbal suggestions of itching, utilizing a design closely analogous to commercially available subliminal audiotapes. Students participated in 1 of 3 groups (n = 21): an experimental group listened to an audiotape with music masking suggestions of itching, Control Group 1 listened to an audiotape with music only, and Control Group 2 listened to suggestions of itching presented supraliminally. Dependent variables included both behavioral and self-report measures of itching. There was no evidence of influence from subliminal suggestion; however, results assessing the influence of supraliminally presented suggestions were mixed for self-report and behavioral measures.

  16. MACVIA-ARIA Sentinel NetworK for allergic rhinitis (MASK-rhinitis): the new generation guideline implementation.

    PubMed

    Bousquet, J; Schunemann, H J; Fonseca, J; Samolinski, B; Bachert, C; Canonica, G W; Casale, T; Cruz, A A; Demoly, P; Hellings, P; Valiulis, A; Wickman, M; Zuberbier, T; Bosnic-Anticevitch, S; Bedbrook, A; Bergmann, K C; Caimmi, D; Dahl, R; Fokkens, W J; Grisle, I; Lodrup Carlsen, K; Mullol, J; Muraro, A; Palkonen, S; Papadopoulos, N; Passalacqua, G; Ryan, D; Valovirta, E; Yorgancioglu, A; Aberer, W; Agache, I; Adachi, M; Akdis, C A; Akdis, M; Annesi-Maesano, I; Ansotegui, I J; Anto, J M; Arnavielhe, S; Arshad, H; Baiardini, I; Baigenzhin, A K; Barbara, C; Bateman, E D; Beghé, B; Bel, E H; Ben Kheder, A; Bennoor, K S; Benson, M; Bewick, M; Bieber, T; Bindslev-Jensen, C; Bjermer, L; Blain, H; Boner, A L; Boulet, L P; Bonini, M; Bonini, S; Bosse, I; Bourret, R; Bousquet, P J; Braido, F; Briggs, A H; Brightling, C E; Brozek, J; Buhl, R; Burney, P G; Bush, A; Caballero-Fonseca, F; Calderon, M A; Camargos, P A M; Camuzat, T; Carlsen, K H; Carr, W; Cepeda Sarabia, A M; Chavannes, N H; Chatzi, L; Chen, Y Z; Chiron, R; Chkhartishvili, E; Chuchalin, A G; Ciprandi, G; Cirule, I; Correia de Sousa, J; Cox, L; Crooks, G; Costa, D J; Custovic, A; Dahlen, S E; Darsow, U; De Carlo, G; De Blay, F; Dedeu, T; Deleanu, D; Denburg, J A; Devillier, P; Didier, A; Dinh-Xuan, A T; Dokic, D; Douagui, H; Dray, G; Dubakiene, R; Durham, S R; Dykewicz, M S; El-Gamal, Y; Emuzyte, R; Fink Wagner, A; Fletcher, M; Fiocchi, A; Forastiere, F; Gamkrelidze, A; Gemicioğlu, B; Gereda, J E; González Diaz, S; Gotua, M; Grouse, L; Guzmán, M A; Haahtela, T; Hellquist-Dahl, B; Heinrich, J; Horak, F; Hourihane, J O 'b; Howarth, P; Humbert, M; Hyland, M E; Ivancevich, J C; Jares, E J; Johnston, S L; Joos, G; Jonquet, O; Jung, K S; Just, J; Kaidashev, I; Kalayci, O; Kalyoncu, A F; Keil, T; Keith, P K; Khaltaev, N; Klimek, L; Koffi N'Goran, B; Kolek, V; Koppelman, G H; Kowalski, M L; Kull, I; Kuna, P; Kvedariene, V; Lambrecht, B; Lau, S; Larenas-Linnemann, D; Laune, D; Le, L T T; Lieberman, P; Lipworth, B; Li, J; Louis, R; Magard, Y; Magnan, A; Mahboub, B; Majer, I; Makela, M J; Manning, P; De Manuel Keenoy, E; Marshall, G D; Masjedi, M R; Maurer, M; Mavale-Manuel, S; Melén, E; Melo-Gomes, E; Meltzer, E O; Merk, H; Miculinic, N; Mihaltan, F; Milenkovic, B; Mohammad, Y; Molimard, M; Momas, I; Montilla-Santana, A; Morais-Almeida, M; Mösges, R; Namazova-Baranova, L; Naclerio, R; Neou, A; Neffen, H; Nekam, K; Niggemann, B; Nyembue, T D; O'Hehir, R E; Ohta, K; Okamoto, Y; Okubo, K; Ouedraogo, S; Paggiaro, P; Pali-Schöll, I; Palmer, S; Panzner, P; Papi, A; Park, H S; Pavord, I; Pawankar, R; Pfaar, O; Picard, R; Pigearias, B; Pin, I; Plavec, D; Pohl, W; Popov, T A; Portejoie, F; Postma, D; Potter, P; Price, D; Rabe, K F; Raciborski, F; Radier Pontal, F; Repka-Ramirez, S; Robalo-Cordeiro, C; Rolland, C; Rosado-Pinto, J; Reitamo, S; Rodenas, F; Roman Rodriguez, M; Romano, A; Rosario, N; Rosenwasser, L; Rottem, M; Sanchez-Borges, M; Scadding, G K; Serrano, E; Schmid-Grendelmeier, P; Sheikh, A; Simons, F E R; Sisul, J C; Skrindo, I; Smit, H A; Solé, D; Sooronbaev, T; Spranger, O; Stelmach, R; Strandberg, T; Sunyer, J; Thijs, C; Todo-Bom, A; Triggiani, M; Valenta, R; Valero, A L; van Hage, M; Vandenplas, O; Vezzani, G; Vichyanond, P; Viegi, G; Wagenmann, M; Walker, S; Wang, D Y; Wahn, U; Williams, D M; Wright, J; Yawn, B P; Yiallouros, P K; Yusuf, O M; Zar, H J; Zernotti, M E; Zhang, L; Zhong, N; Zidarn, M; Mercier, J

    2015-11-01

    Several unmet needs have been identified in allergic rhinitis: identification of the time of onset of the pollen season, optimal control of rhinitis and comorbidities, patient stratification, multidisciplinary team for integrated care pathways, innovation in clinical trials and, above all, patient empowerment. MASK-rhinitis (MACVIA-ARIA Sentinel NetworK for allergic rhinitis) is a simple system centred around the patient which was devised to fill many of these gaps using Information and Communications Technology (ICT) tools and a clinical decision support system (CDSS) based on the most widely used guideline in allergic rhinitis and its asthma comorbidity (ARIA 2015 revision). It is one of the implementation systems of Action Plan B3 of the European Innovation Partnership on Active and Healthy Ageing (EIP on AHA). Three tools are used for the electronic monitoring of allergic diseases: a cell phone-based daily visual analogue scale (VAS) assessment of disease control, CARAT (Control of Allergic Rhinitis and Asthma Test) and e-Allergy screening (premedical system of early diagnosis of allergy and asthma based on online tools). These tools are combined with a clinical decision support system (CDSS) and are available in many languages. An e-CRF and an e-learning tool complete MASK. MASK is flexible and other tools can be added. It appears to be an advanced, global and integrated ICT answer for many unmet needs in allergic diseases which will improve policies and standards. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Evaluation of Synthetic Self-Oscillating Models of the Vocal Folds

    NASA Astrophysics Data System (ADS)

    Hubler, Elizabeth P.; Weiland, Kelley S.; Hancock, Adrienne B.; Plesniak, Michael W.

    2013-11-01

    Approximately 30% of people will suffer from a voice disorder at some point in their lives. The probability doubles for those who rely heavily on their voice, such as teachers and singers. Synthetic vocal fold (VF) models are fabricated and evaluated experimentally in a vocal tract simulator to replicate physiological conditions. Pressure measurements are acquired along the vocal tract and high-speed images are captured at varying flow rates during VF oscillation to facilitate understanding of the characteristics of healthy and damaged VFs. The images are analyzed using a videokymography line-scan technique that has been used to examine VF motion and mucosal wave dynamics in vivo. Clinically relevant parameters calculated from the volume-velocity output of a circumferentially-vented mask (Rothenberg mask) are compared to patient data. This study integrates speech science with engineering and flow physics to overcome current limitations of synthetic VF models to properly replicate normal phonation in order to advance the understanding of resulting flow features, progression of pathological conditions, and medical techniques. Supported by the GW Institute for Biomedical Engineering (GWIBE) and GW Center for Biomimetics and Bioinspired Engineering (COBRE).

  18. Improvement of a block co-polymer (PS-b-PDMS) template etch profile using amorphous carbon layer

    NASA Astrophysics Data System (ADS)

    Oh, JiSoo; Oh, Jong Sik; Sung, DaIn; Yim, SoonMin; Song, SeungWon; Yeom, GeunYoung

    2017-03-01

    Block copolymers (BCPs) are consisted of at least two types of monomers which have covalent bonding. One of the widely investigated BCPs is polystyrene-block-polydimethylsiloxane (PS-b-PDMS), which is used as an alternative patterning method for various deep nanoscale devices due to its high Flory-Huggins interaction parameter (χ), such as optical devices and transistors, replacing conventional photolithography. As an alternate or supplementary nextgeneration lithography technology to extreme ultraviolet lithography (EUVL), BCP lithography utilizing the DSA of BCP has been actively studied. However, the nanoscale BCP mask material is easily damaged by the plasma and has a very low etch selectivity over bottom semiconductor materials, because it is composed of polymeric materials even though it contains Si in PDMS. In this study, an amorphous carbon layer (ACL) was inserted as a hardmask material between BCP and materials to be patterned, and, by using O2 plasmas, the characteristics of dry etching of ACL for high aspect ratio (HAR) using a 10 nm PDMS pattern were investigated. The results showed that, by using a PS-b-PDMS pattern with an aspect ratio of 0.3 0.9:1, a HAR PDMS/ACL double layer mask with an aspect ratio of 10:1 could be fabricated. In addition, by the optimization of the plasma etch process, ACL masks with excellent sidewall roughness (SWR,1.35 nm) and sidewall angle (SWA, 87.9˚) could be fabricated.

  19. Motion-Induced Blindness and Troxler Fading: Common and Different Mechanisms

    PubMed Central

    Bonneh, Yoram S.; Donner, Tobias H.; Cooperman, Alexander; Heeger, David J.; Sagi, Dov

    2014-01-01

    Extended stabilization of gaze leads to disappearance of dim visual targets presented peripherally. This phenomenon, known as Troxler fading, is thought to result from neuronal adaptation. Intense targets also disappear intermittently when surrounded by a moving pattern (the “mask”), a phenomenon known as motion-induced blindness (MIB). The similar phenomenology and dynamics of these disappearances may suggest that also MIB is, likewise, solely due to adaptation, which may be amplified by the presence of the mask. Here we directly compared the dependence of both phenomena on target contrast. Observers reported the disappearance and reappearance of a target of varying intensity (contrast levels: 8%–80%). MIB was induced by adding a mask that moved at one of various different speeds. The results revealed a lawful effect of contrast in both MIB and Troxler fading, but with opposite trends. Increasing target contrast increased (doubled) the rate of disappearance events for MIB, but decreased the disappearance rate to half in Troxler fading. The target mean invisible period decreased equally strongly with target contrast in MIB and in Troxler fading. The results suggest that both MIB and Troxler are equally affected by contrast adaptation, but that the rate of MIB is governed by an additional mechanism, possibly involving antagonistic processes between neuronal populations processing target and mask. Our results link MIB to other bi-stable visual phenomena that involve neuronal competition (such as binocular rivalry), which exhibit an analogous dependency on the strength of the competing stimulus components. PMID:24658600

  20. Acute tryptophan depletion attenuates conscious appraisal of social emotional signals in healthy female volunteers.

    PubMed

    Beacher, Felix D C C; Gray, Marcus A; Minati, Ludovico; Whale, Richard; Harrison, Neil A; Critchley, Hugo D

    2011-02-01

    Acute tryptophan depletion (ATD) decreases levels of central serotonin. ATD thus enables the cognitive effects of serotonin to be studied, with implications for the understanding of psychiatric conditions, including depression. To determine the role of serotonin in conscious (explicit) and unconscious/incidental processing of emotional information. A randomized, double-blind, cross-over design was used with 15 healthy female participants. Subjective mood was recorded at baseline and after 4 h, when participants performed an explicit emotional face processing task, and a task eliciting unconscious processing of emotionally aversive and neutral images presented subliminally using backward masking. ATD was associated with a robust reduction in plasma tryptophan at 4 h but had no effect on mood or autonomic physiology. ATD was associated with significantly lower attractiveness ratings for happy faces and attenuation of intensity/arousal ratings of angry faces. ATD also reduced overall reaction times on the unconscious perception task, but there was no interaction with emotional content of masked stimuli. ATD did not affect breakthrough perception (accuracy in identification) of masked images. ATD attenuates the attractiveness of positive faces and the negative intensity of threatening faces, suggesting that serotonin contributes specifically to the appraisal of the social salience of both positive and negative salient social emotional cues. We found no evidence that serotonin affects unconscious processing of negative emotional stimuli. These novel findings implicate serotonin in conscious aspects of active social and behavioural engagement and extend knowledge regarding the effects of ATD on emotional perception.

  1. ELECTRIC PULSE GENERATOR

    DOEpatents

    Buntenbach, R.W.

    1959-06-01

    S>An electro-optical apparatus is described which produces electric pulses in programmed sequences at times and durations controlled with great accuracy. An oscilloscope CRT is supplied with signals to produce a luminous spot moving in a circle. An opaque mask with slots of variable width transmits light from the spot to a photoelectric transducer. For shorter pulse decay times a CRT screen which emits UV can be used with a UVtransmitting filter and a UV- sensitive photoelectric cell. Pulses are varied by changing masks or by using masks with variable slots. This device may be used in multiple arrangements to produce other pulse aT rangements, or it can be used to trigger an electronic pulse generator. (T.R.H.)

  2. Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial.

    PubMed

    Oto, Jun; Li, Qian; Kimball, William R; Wang, Jingping; Sabouri, Abdolnabi S; Harrell, Priscilla G; Kacmarek, Robert M; Jiang, Yandong

    2013-12-23

    Upper airway obstruction (UAO) is a major problem in unconscious subjects, making full face mask ventilation difficult. The mechanism of UAO in unconscious subjects shares many similarities with that of obstructive sleep apnea (OSA), especially the hypotonic upper airway seen during rapid eye movement sleep. Continuous positive airway pressure (CPAP) via nasal mask is more effective at maintaining airway patency than a full face mask in patients with OSA. We hypothesized that CPAP via nasal mask and ventilation (nCPAP) would be more effective than full face mask CPAP and ventilation (FmCPAP) for unconscious subjects, and we tested our hypothesis during induction of general anesthesia for elective surgery. In total, 73 adult subjects requiring general anesthesia were randomly assigned to one of four groups: nCPAP P0, nCPAP P5, FmCPAP P0, and FmCPAP P5, where P0 and P5 represent positive end-expiratory pressure (PEEP) 0 and 5 cm H2O applied prior to induction. After apnea, ventilation was initiated with pressure control ventilation at a peak inspiratory pressure over PEEP (PIP/PEEP) of 20/0, then 20/5, and finally 20/10 cm H2O, each applied for 1 min. At each pressure setting, expired tidal volume (Vte) was calculated by using a plethysmograph device. The rate of effective tidal volume (Vte > estimated anatomical dead space) was higher (87.9% vs. 21.9%; P<0.01) and the median Vte was larger (6.9 vs. 0 mL/kg; P<0.01) with nCPAP than with FmCPAP. Application of CPAP prior to induction of general anesthesia did not affect Vte in either approach (nCPAP pre- vs. post-; 7.9 vs. 5.8 mL/kg, P = 0.07) (FmCPAP pre- vs. post-; 0 vs. 0 mL/kg, P = 0.11). nCPAP produced more effective tidal volume than FmCPAP in unconscious subjects. ClinicalTrials.gov identifier: NCT01524614.

  3. Active Masks and Active Inhibition: A Comment on Lleras and Enns (2004) and on Verleger, Jaskowski, Aydemir, van der Lubbe, and Groen (2004)

    ERIC Educational Resources Information Center

    Schlaghecken, Friederike; Eimer, Martin

    2006-01-01

    Verleger, Jaskowski, Aydemir, van der Lubbe, and Groen (see record 2004-21166-002) and Lleras and Enns (see record 2004-21166-001) have argued that negative compatibility effects (NCEs) obtained with masked primes do not reflect self-inhibition processes in motor control. Instead, NCEs are assumed to reflect activation of the response opposite to…

  4. Matching OPC and masks on 300-mm lithography tools utilizing variable illumination settings

    NASA Astrophysics Data System (ADS)

    Palitzsch, Katrin; Kubis, Michael; Schroeder, Uwe P.; Schumacher, Karl; Frangen, Andreas

    2004-05-01

    CD control is crucial to maximize product yields on 300mm wafers. This is particularly true for DRAM frontend lithography layers, like gate level, and deep trench (capacitor) level. In the DRAM process, large areas of the chip are taken up by array structures, which are difficult to structure due to aggressive pitch requirements. Consequently, the lithography process is centered such that the array structures are printed on target. Optical proximity correction is applied to print gate level structures in the periphery circuitry on target. Only slight differences of the different Zernike terms can cause rather large variations of the proximity curves, resulting in a difference of isolated and semi-isolated lines printed on different tools. If the deviations are too large, tool specific OPC is needed. The same is true for deep trench level, where the length to width ratio of elongated contact-like structures is an important parameter to adjust the electrical properties of the chip. Again, masks with specific biases for tools with different Zernikes are needed to optimize product yield. Additionally, mask making contributes to the CD variation of the process. Theoretically, the CD deviation caused by an off-centered mask process can easily eat up the majority of the CD budget of a lithography process. In practice, masks are very often distributed intelligently among production tools, such that lens and mask effects cancel each other. However, only dose adjusting and mask allocation may still result in a high CD variation with large systematical contributions. By adjusting the illumination settings, we have successfully implemented a method to reduce CD variation on our advanced processes. Especially inner and outer sigma for annular illumination, and the numerical aperture, can be optimized to match mask and stepper properties. This process will be shown to overcome slight lens and mask differences effectively. The effects on lithography process windows have to be considered, nonetheless.

  5. Forward masking of dynamic acoustic intensity: effects of intensity region and end-level.

    PubMed

    Olsen, Kirk N; Stevens, Catherine J

    2012-01-01

    Overestimation of loudness change typically occurs in response to up-ramp auditory stimuli (increasing intensity) relative to down-ramps (decreasing intensity) matched on frequency, duration, and end-level. In the experiment reported, forward masking is used to investigate a sensory component of up-ramp overestimation: persistence of excitation after stimulus presentation. White-noise and synthetic vowel 3.6 s up-ramp and down-ramp maskers were presented over two regions of intensity change (40-60 dB SPL, 60-80 dB SPL). Three participants detected 10 ms 1.5 kHz pure tone signals presented at masker-offset to signal-offset delays of 10, 20, 30, 50, 90, 170 ms. Masking magnitude was significantly greater in response to up-ramps compared with down-ramps for masker-signal delays up to and including 50 ms. When controlling for an end-level recency bias (40-60 dB SPL up-ramp vs 80-60 dB SPL down-ramp), the difference in masking magnitude between up-ramps and down-ramps was not significant at each masker-signal delay. Greater sensory persistence in response to up-ramps is argued to have minimal effect on perceptual overestimation of loudness change when response biases are controlled. An explanation based on sensory adaptation is discussed.

  6. Joint Service Aircrew Mask (JSAM) - Tactical Aircraft (TA) A/P22P-14A Respirator Assembly (V)3: Noise Attenuation and Speech Intelligibility Performance with Double Hearing Protection, HGU-55A/P JHMCS Flight Helmet

    DTIC Science & Technology

    2017-03-01

    in an environment 71-115 dB Sound Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme... Test (MRT) score as listed below. Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a...minimum of ten talkers and of ten listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication amplification. Test must

  7. Advanced detectors and signal processing

    NASA Technical Reports Server (NTRS)

    Greve, D. W.; Rasky, P. H. L.; Kryder, M. H.

    1986-01-01

    Continued progress is reported toward development of a silicon on garnet technology which would allow fabrication of advanced detection and signal processing circuits on bubble memories. The first integrated detectors and propagation patterns have been designed and incorporated on a new mask set. In addition, annealing studies on spacer layers are performed. Based on those studies, a new double layer spacer is proposed which should reduce contamination of the silicon originating in the substrate. Finally, the magnetic sensitivity of uncontaminated detectors from the last lot of wafers is measured. The measured sensitivity is lower than anticipated but still higher than present magnetoresistive detectors.

  8. Effect of Three Different Core Materials on Masking Ability of a Zirconia Ceramic.

    PubMed

    Tabatabaian, Farhad; Masoomi, Faeze; Namdari, Mahshid; Mahshid, Minoo

    2016-09-01

    Masking ability of a restorative material plays a role in hiding colored substructures; however, the masking ability of zirconia ceramic (ZRC) has not yet been clearly understood in zirconia-based restorations. This study evaluated the effect of three different core materials on masking ability of a ZRC. Ten zirconia disc samples, 0.5mm in thickness and 10mm in diameter, were fabricated. A white (W) substrate (control) and three substrates of nickel-chromium alloy (NCA), non-precious gold alloy (NPGA), and ZRC were prepared. The zirconia discs were placed on the four types of substrates for spectrophotometry. The L*, a*, and b* values of the specimens were measured by a spectrophotometer and color change (ΔE) values were calculated to determine color differences between the test and control groups and were then compared with the perceptual threshold. Randomized block ANOVA and Bonferroni test analyzed the data. A significance level of 0.05 was considered. The mean and standard deviation values of ΔE for NCA, NPGA, and ZRC groups were 10.26±2.43, 9.45±1.74, and 6.70±1.91 units, respectively. Significant differences were found in the ΔE values between ZRC and the other two experimental groups (NCA and NPGA; P<0.0001 and P=0.001, respectively). The ΔE values for the groups were more than the predetermined perceptual threshold. Within the limitations of this study, it was concluded that the tested ZRC could not well mask the examined core materials.

  9. Sex differences in neural responses to subliminal sad and happy faces in healthy individuals: Implications for depression.

    PubMed

    Victor, Teresa A; Drevets, Wayne C; Misaki, Masaya; Bodurka, Jerzy; Savitz, Jonathan

    2017-01-02

    Twice as many women as men suffer from mood and anxiety disorders, yet the biological underpinnings of this phenomenon have been understudied and remain unclear. We and others have shown that the hemodynamic response to subliminally presented sad or happy faces during functional MRI (fMRI) is a robust biomarker for the attentional bias toward negative information classically observed in major depression. Here we used fMRI to compare the performance of healthy females (n = 28) and healthy males (n = 28) on a backward masking task using a fast event-related design with gradient-recalled, echoplanar imaging with sensitivity encoding. The image data were compared across groups using a region-of-interest analysis with small-volume correction to control for multiple testing (P corrected  < 0.05, cluster size ≥ 20 voxels). Notably, compared with males, females showed greater BOLD activity in the subgenual anterior cingulate cortex (sgACC) and the right hippocampus when viewing masked sad vs. masked happy faces. Furthermore, females displayed reduced BOLD activity in the right pregenual ACC and left amygdala when viewing masked happy vs. masked neutral faces. Given that we have previously reported similar findings for depressed participants compared with healthy controls (regardless of gender), our results raise the possibility that on average healthy females show subtle emotional processing biases that conceivably reflect a subgroup of women predisposed to depression. Nevertheless, we note that the differences between males and females were small and derived from region-of-interest rather than voxelwise analyses. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Size-Selective Synthesis and Stabilization of Small Silver Nanoparticles on TiO 2 Partially Masked by SiO 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bo, Zhenyu; Eaton, Todd R.; Gallagher, James R.

    Controlling metal nanoparticle size is one of the principle challenges in developing new supported catalysts. Typical methods where a metal salt is deposited and reduced can result in a polydisperse mixture of metal nanoparticles, especially at higher loading. Polydispersity can exacerbate the already significant challenge of controlling sintering at high temperatures, which decreases catalytic surface area. Here, we demonstrate the size-selective photoreduction of Ag nanoparticles on TiO2 whose surface has been partially masked with a thin SiO2 layer. To synthesize this layered oxide material, TiO2 particles are grafted with tert-butylcalix[4]arene molecular templates (~2 nm in diameter) at surface densities ofmore » 0.05–0.17 templates.nm–2, overcoated with ~2 nm of SiO2 through repeated condensation cycles of limiting amounts of tetraethoxysilane (TEOS), and the templates are removed oxidatively. Ag photodeposition results in uniform nanoparticle diameters ≤ 3.5 nm (by transmission electron microscopy (TEM)) on the partially masked TiO2, whereas Ag nanoparticles deposited on the unmodified TiO2 are larger and more polydisperse (4.7 ± 2.7 nm by TEM). Furthermore, Ag nanoparticles on the partially masked TiO2 do not sinter after heating at 450 °C for 3 h, while nanoparticles on the control surfaces sinter and grow by at least 30%, as is typical. Overall, this new synthesis approach controls metal nanoparticle dispersion and enhances thermal stability, and this facile synthesis procedure is generalizable to other TiO2-supported nanoparticles and sizes and may find use in the synthesis of new catalytic materials.« less

  11. Adhesive Systems as an Alternative Material for Color Masking of White Spot Lesions: Do They Work?

    PubMed

    de Lacerda, Ana Júlia Farias; da Silva Ávila, Daniele Mara; Borges, Alessandra Buhler; Pucci, Cesar Rogerio; Rocha Gomes Torres, Carlos

    2016-01-01

    To evaluate the color masking effect of infiltration treatment of artificial white spot lesions (AWSL) using a dedicated resin in comparison to different adhesive systems. Enamel/dentin specimens were obtained from bovine incisors and baseline color was assessed using a reflectance spectrophotometer, according to the CIE L*a*b* system. AWSL were produced using a buffered acid solution and a new color evaluation was performed. The specimens were divided into 8 groups: control: artificial saliva changed daily for 7 days; IC: infiltrating resin Icon; EC: EquiaCoat; FU: Futurabond U; SBU: Single Bond U; SBMP: Scotchbond MP; OB: OptibondFL; BF: Bioforty. After the treatments, the color was evaluated again and the values for the parameters ΔL (change in lightness), Δa (change in chroma), Δb (change in hue), and ΔE (general color difference) were calculated in relation to baseline. Data were analyzed by one-way ANOVA and Tukey's tests. After treatment, ANOVA showed significant differences for all parameters (p = 0.001). Tukey's test showed the greatest lightness reduction (ΔL) for the IC group, followed by EC, FU, and SBU. The SBMP, OB, and BF groups were similar to the control. For Δb values, all groups showed differences in relation to the control, with no differences between them. In relation to ΔE, all groups showed differences in relation to the control (ΔE = 5.24), with no significant differences between them. ΔE values after application of all resinous materials were lower than the threshold of 3.7, indicating effective color masking. The Icon infiltrant produced a greater lightness reduction of white lesions (ΔL). For general color difference (ΔE), all the resinous materials tested were able to color mask artificial AWSL.

  12. Topical Mannitol Reduces Capsaicin-Induced Pain: Results of a Pilot-Level, Double-Blind, Randomized Controlled Trial.

    PubMed

    Bertrand, Helene; Kyriazis, Marylene; Reeves, K Dean; Lyftogt, John; Rabago, David

    2015-11-01

    Capsaicin specifically activates, and then gradually exhausts, the transient receptor potential vanilloid type 1 (TRPV1) receptor, a key receptor in neuropathic pain. Activation of the TRPV-1 receptor is accompanied by burning pain. A natural substance or medication that can reduce the burning pain resulting from capsaicin application may have therapeutic potential in neuropathic pain. To assess the pain-relieving effects of a mannitol-containing cream in a capsaicin-based pain model. Randomized, placebo-controlled, double-blind clinical trial. Outpatient pain clinic. Twenty-five adults with pain-free lips. Capsaicin .075% cream was applied to both halves of each participant's upper lip, inducing pain via stimulation of the transient receptor potential vanilloid 1 (TRPV1, capsaicin) receptor, then removed after 5 minutes or when participants reported a burning pain of 8/10, whichever came first. A cream containing mannitol and the same cream without mannitol (control) were then immediately applied, 1 on each side of the lip, in an allocation-masked manner. Participants self-recorded a numeric rating scale (NRS, 0-10) pain score for each side of the lip per minute for 10 minutes. A t-test was performed to evaluate the pain score change from baseline between each side of the lip at each recording. Area under the curve (AUC) analysis was used to determine the overall difference between groups. Participants reached a capsaicin-induced pain level of 7.8 ± 1.0 points in 3.3 ± 1.6 minutes that was equal on both sides of the lip. Both groups reported progressive diminution of pain over the 10-minute study period. However, participants reported significantly reduced pain scores on the mannitol cream half-lip compared to control at 3 through 10 minutes (P < .05) and in AUC analysis (P < .001). Mannitol cream reduced self-reported pain scores in a capsaicin pain model more rapidly than a control cream, potentially via a TRPV1 receptor effect. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  13. Validation of masks for determination of V̇O2 max in horses exercising at high intensity.

    PubMed

    Sides, R H; Kirkpatrick, R; Renner, E; Gough, K; Katz, L M; Evans, D L; Bayly, W M

    2018-01-01

    The need for a horse to be ridden while wearing a measurement device that allows unrestricted ventilation and gas exchange has hampered accurate measurement of its maximal oxygen consumption (V̇O 2 max) under field conditions. Design and validate a facemask with the potential to measure V̇O 2 max accurately in the field. Experiment with 6 × 6 Latin square design. Two variations of a mask and associated electronic control module (ECM) were designed to enable breath-by-breath measurement of airflows through two 7.8 cm diameter pneumotachometers located 7.5 cm in front of each narus. The ECM was comprised of an analogue-to-digital converter and a lithium-ion battery that provided power and signal filtering to the pneumotachometers and an oxygen sensing cell, and powered a pump connected to gas sampling ports between the nares and pneumotachometers. Airflow and oxygen content of inspired and expired gases were recorded through the ECM and electronically transferred to a notebook. V̇O 2 was determined from these recordings using a customised software program. Mask B encased the lower jaw. Mask R left the jaw free so the horse could wear a bit if ridden. V̇O 2 max and arterial blood gases were measured in 6 horses during multiple treadmill tests. Each mask was worn twice and results compared to those from an established open flow-through system (O) by ANOVA-RM (P<0.05). System utility was evaluated using the intraclass correlation coefficient of 4 independent raters. Blood gases and V̇O 2 max (151.9±7.0 [mean±s.d.; O], 151.5±9.6 [B], 149.5±7.5 [R] ml/[kg.min]) were not different between masks. V̇O 2 max measures were reproducible for each mask. Intraclass correlation coefficient between raters = 0.99. Some rebreathing of expired air from mask dead space. Masks capable of measuring V̇O 2 max during treadmill exercise were developed, tested and found to be accurate. Mask R has potential application to measurement of V̇O 2 max under field conditions. © 2017 EVJ Ltd.

  14. Availability, consistency and evidence-base of policies and guidelines on the use of mask and respirator to protect hospital health care workers: a global analysis

    PubMed Central

    2013-01-01

    Background Currently there is an ongoing debate and limited evidence on the use of masks and respirators for the prevention of respiratory infections in health care workers (HCWs). This study aimed to examine available policies and guidelines around the use of masks and respirators in HCWs and to describe areas of consistency between guidelines, as well as gaps in the recommendations, with reference to the WHO and the CDC guidelines. Methods Policies and guidelines related to mask and respirator use for the prevention of influenza, SARS and TB were examined. Guidelines from the World Health Organization (WHO), the Center for Disease Control and Prevention (CDC), three high-income countries and six low/middle-income countries were selected. Results Uniform recommendations are made by the WHO and the CDC in regards to protecting HCWs against seasonal influenza (a mask for low risk situations and a respirator for high risk situations) and TB (use of a respirator). However, for pandemic influenza and SARS, the WHO recommends mask use in low risk and respirators in high risk situations, whereas, the CDC recommends respirators in both low and high risk situations. Amongst the nine countries reviewed, there are variations in the recommendations for all three diseases. While, some countries align with the WHO recommendations, others align with those made by the CDC. The choice of respirator and the level of filtering ability vary amongst the guidelines and the different diseases. Lastly, none of the policies discuss reuse, extended use or the use of cloth masks. Conclusion Currently, there are significant variations in the policies and recommendations around mask and respirator use for protection against influenza, SARS and TB. These differences may reflect the scarcity of level-one evidence available to inform policy development. The lack of any guidelines on the use of cloth masks, despite widespread use in many low and middle-income countries, remains a policy gap. Health organizations and countries should jointly evaluate the available evidence, prioritize research to inform evidence gaps, and develop consistent policy on masks and respirator use in the health care setting. PMID:23725338

  15. Availability, consistency and evidence-base of policies and guidelines on the use of mask and respirator to protect hospital health care workers: a global analysis.

    PubMed

    Chughtai, Abrar Ahmad; Seale, Holly; MacIntyre, Chandini Raina

    2013-05-31

    Currently there is an ongoing debate and limited evidence on the use of masks and respirators for the prevention of respiratory infections in health care workers (HCWs). This study aimed to examine available policies and guidelines around the use of masks and respirators in HCWs and to describe areas of consistency between guidelines, as well as gaps in the recommendations, with reference to the WHO and the CDC guidelines. Policies and guidelines related to mask and respirator use for the prevention of influenza, SARS and TB were examined. Guidelines from the World Health Organization (WHO), the Center for Disease Control and Prevention (CDC), three high-income countries and six low/middle-income countries were selected. Uniform recommendations are made by the WHO and the CDC in regards to protecting HCWs against seasonal influenza (a mask for low risk situations and a respirator for high risk situations) and TB (use of a respirator). However, for pandemic influenza and SARS, the WHO recommends mask use in low risk and respirators in high risk situations, whereas, the CDC recommends respirators in both low and high risk situations. Amongst the nine countries reviewed, there are variations in the recommendations for all three diseases. While, some countries align with the WHO recommendations, others align with those made by the CDC. The choice of respirator and the level of filtering ability vary amongst the guidelines and the different diseases. Lastly, none of the policies discuss reuse, extended use or the use of cloth masks. Currently, there are significant variations in the policies and recommendations around mask and respirator use for protection against influenza, SARS and TB. These differences may reflect the scarcity of level-one evidence available to inform policy development. The lack of any guidelines on the use of cloth masks, despite widespread use in many low and middle-income countries, remains a policy gap. Health organizations and countries should jointly evaluate the available evidence, prioritize research to inform evidence gaps, and develop consistent policy on masks and respirator use in the health care setting.

  16. Three-dimensional rearrangement of single atoms using actively controlled optical microtraps.

    PubMed

    Lee, Woojun; Kim, Hyosub; Ahn, Jaewook

    2016-05-02

    We propose and demonstrate three-dimensional rearrangements of single atoms. In experiments performed with single 87Rb atoms in optical microtraps actively controlled by a spatial light modulator, we demonstrate various dynamic rearrangements of up to N = 9 atoms including rotation, 2D vacancy filling, guiding, compactification, and 3D shuffling. With the capability of a phase-only Fourier mask to generate arbitrary shapes of the holographic microtraps, it was possible to place single atoms at arbitrary geometries of a few μm size and even continuously reconfigure them by conveying each atom. For this purpose, we loaded a series of computer-generated phase masks in the full frame rate of 60 Hz of the spatial light modulator, so the animation of phase mask transformed the holographic microtraps in real time, driving each atom along the assigned trajectory. Possible applications of this method of transformation of single atoms include preparation of scalable quantum platforms for quantum computation, quantum simulation, and quantum many-body physics.

  17. The pilus usher controls protein interactions via domain masking and is functional as an oligomer

    DOE PAGES

    Werneburg, Glenn T.; Li, Huilin; Henderson, Nadine S.; ...

    2015-06-08

    The chaperone/usher (CU) pathway is responsible for biogenesis of organelles termed pili or fimbriae in Gram-negative bacteria. Type 1 pili expressed by uropathogenic Escherichia coli are prototypical structures assembled by the CU pathway. Assembly and secretion of pili by the CU pathway requires a dedicated periplasmic chaperone and a multidomain outer membrane protein termed the usher (FimD). We show that the FimD C-terminal domains provide the high-affinity substrate binding site, but that these domains are masked in the resting usher. Domain masking requires the FimD plug domain, which served as a central switch controlling usher activation. In addition, we demonstratemore » that usher molecules can act in trans for pilus biogenesis, providing conclusive evidence for a functional usher oligomer. These results reveal mechanisms by which molecular machines such as the usher regulate and harness protein-protein interactions, and suggest that ushers may interact in a cooperative manner during pilus assembly in bacteria.« less

  18. Tachistoscopic illumination and masking of real scenes.

    PubMed

    Chichka, David; Philbeck, John W; Gajewski, Daniel A

    2015-03-01

    Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and directional locations of objects in 2-D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues can be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This article describes the system and the timing characteristics of each component. We verified the system's ability to control exposure to time scales as low as a few milliseconds.

  19. Inspection system qualification and integration into the mask manufacturing environment

    NASA Astrophysics Data System (ADS)

    LaVoy, Rosanne; Fujioka, Ron

    1995-12-01

    Integration of a mask inspection system into a manufacturing environment poses new challenges to both the inspection engineer and the equipment supplier. Traditional specifications (limited primarily to sensitivity and uptime) are no longer sufficient to successfully integrate a system into a 7 by 24 manufacturing area with multiple systems. Issues such as system sensitivity matching, sensitivity characterization by defect type, operator training and certification standards, and real-time SPC control of the systems must be addressed. This paper outlines some of the techniques Intel Mask Operation uses for integration of a new inspection system into the manufacturing line. Specifically moving a beta- site type tool out of the beta-site mode and into volume production. Examples are presented, including installation for manufacturing (including ergonomic modifications), techniques for system-to-system matching, use of SPC charts to monitor system performance, and operator training/certifications. Relationships between system PMs, or other environmental changes, and the system sensitivity SPC control charts also are discussed.

  20. Topical interleukin 1 receptor antagonist for treatment of dry eye disease: a randomized clinical trial.

    PubMed

    Amparo, Francisco; Dastjerdi, Mohammad H; Okanobo, Andre; Ferrari, Giulio; Smaga, Leila; Hamrah, Pedram; Jurkunas, Ula; Schaumberg, Debra A; Dana, Reza

    2013-06-01

    The immunopathogenic mechanisms of dry eye disease (DED), one of the most common ophthalmic conditions, is incompletely understood. Data from this prospective, double-masked, randomized trial demonstrate that targeting interleukin 1 (IL-1) by topical application of an IL-1 antagonist is efficacious in significantly reducing DED-related patient symptoms and corneal epitheliopathy. To evaluate the safety and efficacy of treatment with the topical IL-1 receptor antagonist anakinra (Kineret; Amgen Inc) in patients having DED associated with meibomian gland dysfunction. Prospective phase 1/2, randomized, double-masked, vehicle-controlled clinical trial. Seventy-five patients with refractory DED. Participants were randomized to receive treatment with topical anakinra, 2.5% (n = 30), anakinra, 5% (n = 15), or vehicle (1% carboxymethylcellulose) (n = 30) 3 times daily for 12 weeks. Primary outcomes were corneal fluorescein staining (CFS), complete bilateral CFS clearance, dry eye-related symptoms as measured by the Ocular Surface Disease Index, tear film breakup time, and meibomian gland secretion quality. Topical anakinra was well tolerated compared with vehicle, with no reports of serious adverse reactions attributable to the therapy. After 12 weeks of therapy, participants treated with anakinra, 2.5%, achieved a 46% reduction in their mean CFS score (P = .12 compared with vehicle and P < .001 compared with baseline); participants treated with anakinra, 5%, achieved a 17% reduction in their mean CFS score (P = .88 compared with vehicle and P = .33 compared with baseline); and patients treated with vehicle achieved a 19% reduction in their mean CFS score (P = .11). Complete bilateral CFS clearance was noted in 8 of 28 patients (29%) treated with anakinra, 2.5%, vs in 2 of 29 patients (7%) treated with vehicle (P = .03). By week 12, treatment with anakinra, 2.5%, and treatment with anakinra, 5%, led to significant reductions in symptoms of 30% and 35%, respectively (P = .02 and P = .01, respectively, compared with vehicle); treatment with vehicle led to a 5% reduction in symptoms. Treatment with topical anakinra, 2.5%, for 12 weeks was safe and significantly reduced symptoms and corneal epitheliopathy in patients with DED. These data suggest that the use of an IL-1 antagonist may have a role as a novel therapeutic option for patients with DED. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00681109.

  1. Collinear masking effect in visual search is independent of perceptual salience.

    PubMed

    Jingling, Li; Lu, Yi-Hui; Cheng, Miao; Tseng, Chia-Huei

    2017-07-01

    Searching for a target in a salient region should be easier than looking for one in a nonsalient region. However, we previously discovered a contradictory phenomenon in which a local target in a salient structure was more difficult to find than one in the background. The salient structure was constructed of orientation singletons aligned to each other to form a collinear structure. In the present study, we undertake to determine whether such a masking effect was a result of salience competition between a global structure and the local target. In the first 3 experiments, we increased the salience value of the local target with the hope of adding to its competitive advantage and eventually eliminating the masking effect; nevertheless, the masking effect persisted. In an additional 2 experiments, we reduced salience of the global collinear structure by altering the orientation of the background bars and the masking effect still emerged. Our salience manipulations were validated by a controlled condition in which the global structure was grouped noncollinearly. In this case, local target salience increase (e.g., onset) or global distractor salience reduction (e.g., randomized flanking orientations) effectively removed the facilitation effect of the noncollinear structure. Our data suggest that salience competition is unlikely to explain the collinear masking effect, and other mechanisms such as contour integration, border formation, or the crowding effect may be prospective candidates for further investigation.

  2. A schlieren optical study of the human cough with and without wearing masks for aerosol infection control

    PubMed Central

    Tang, Julian W.; Liebner, Thomas J.; Craven, Brent A.; Settles, Gary S.

    2009-01-01

    Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask). PMID:19815575

  3. A schlieren optical study of the human cough with and without wearing masks for aerosol infection control.

    PubMed

    Tang, Julian W; Liebner, Thomas J; Craven, Brent A; Settles, Gary S

    2009-12-06

    Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask).

  4. Getting the cocktail party started: masking effects in speech perception

    PubMed Central

    Evans, S; McGettigan, C; Agnew, ZK; Rosen, S; Scott, SK

    2016-01-01

    Spoken conversations typically take place in noisy environments and different kinds of masking sounds place differing demands on cognitive resources. Previous studies, examining the modulation of neural activity associated with the properties of competing sounds, have shown that additional speech streams engage the superior temporal gyrus. However, the absence of a condition in which target speech was heard without additional masking made it difficult to identify brain networks specific to masking and to ascertain the extent to which competing speech was processed equivalently to target speech. In this study, we scanned young healthy adults with continuous functional Magnetic Resonance Imaging (fMRI), whilst they listened to stories masked by sounds that differed in their similarity to speech. We show that auditory attention and control networks are activated during attentive listening to masked speech in the absence of an overt behavioural task. We demonstrate that competing speech is processed predominantly in the left hemisphere within the same pathway as target speech but is not treated equivalently within that stream, and that individuals who perform better in speech in noise tasks activate the left mid-posterior superior temporal gyrus more. Finally, we identify neural responses associated with the onset of sounds in the auditory environment, activity was found within right lateralised frontal regions consistent with a phasic alerting response. Taken together, these results provide a comprehensive account of the neural processes involved in listening in noise. PMID:26696297

  5. Real-Time Functional Magnetic Resonance Imaging Amygdala Neurofeedback Changes Positive Information Processing in Major Depressive Disorder.

    PubMed

    Young, Kymberly D; Misaki, Masaya; Harmer, Catherine J; Victor, Teresa; Zotev, Vadim; Phillips, Raquel; Siegle, Greg J; Drevets, Wayne C; Bodurka, Jerzy

    2017-10-15

    In participants with major depressive disorder who are trained to upregulate their amygdalar hemodynamic responses during positive autobiographical memory recall with real-time functional magnetic resonance imaging neurofeedback (rtfMRI-nf) training, depressive symptoms diminish. This study tested whether amygdalar rtfMRI-nf also changes emotional processing of positive and negative stimuli in a variety of behavioral and imaging tasks. Patients with major depressive disorder completed two rtfMRI-nf sessions (18 received amygdalar rtfMRI-nf, 16 received control parietal rtfMRI-nf). One week before and following rtfMRI-nf training, participants performed tasks measuring responses to emotionally valenced stimuli including a backward-masking task, which measures the amygdalar hemodynamic response to emotional faces presented for traditionally subliminal duration and followed by a mask, and the Emotional Test Battery in which reaction times and performance accuracy are measured during tasks involving emotional faces and words. During the backward-masking task, amygdalar responses increased while viewing masked happy faces but decreased to masked sad faces in the experimental versus control group following rtfMRI-nf. During the Emotional Test Battery, reaction times decreased to identification of positive faces and during self-identification with positive words and vigilance scores increased to positive faces and decreased to negative faces during the faces dot-probe task in the experimental versus control group following rtfMRI-nf. rtfMRI-nf training to increase the amygdalar hemodynamic response to positive memories was associated with changes in amygdalar responses to happy and sad faces and improved processing of positive stimuli during performance of the Emotional Test Battery. These results may suggest that amygdalar rtfMRI-nf training alters responses to emotional stimuli in a manner similar to antidepressant pharmacotherapy. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  6. Splendidly blended: a machine learning set up for CDU control

    NASA Astrophysics Data System (ADS)

    Utzny, Clemens

    2017-06-01

    As the concepts of machine learning and artificial intelligence continue to grow in importance in the context of internet related applications it is still in its infancy when it comes to process control within the semiconductor industry. Especially the branch of mask manufacturing presents a challenge to the concepts of machine learning since the business process intrinsically induces pronounced product variability on the background of small plate numbers. In this paper we present the architectural set up of a machine learning algorithm which successfully deals with the demands and pitfalls of mask manufacturing. A detailed motivation of this basic set up followed by an analysis of its statistical properties is given. The machine learning set up for mask manufacturing involves two learning steps: an initial step which identifies and classifies the basic global CD patterns of a process. These results form the basis for the extraction of an optimized training set via balanced sampling. A second learning step uses this training set to obtain the local as well as global CD relationships induced by the manufacturing process. Using two production motivated examples we show how this approach is flexible and powerful enough to deal with the exacting demands of mask manufacturing. In one example we show how dedicated covariates can be used in conjunction with increased spatial resolution of the CD map model in order to deal with pathological CD effects at the mask boundary. The other example shows how the model set up enables strategies for dealing tool specific CD signature differences. In this case the balanced sampling enables a process control scheme which allows usage of the full tool park within the specified tight tolerance budget. Overall, this paper shows that the current rapid developments off the machine learning algorithms can be successfully used within the context of semiconductor manufacturing.

  7. Oxygen therapy for cluster headache. A mask comparison trial. A single-blinded, placebo-controlled, crossover study.

    PubMed

    Petersen, Anja S; Barloese, Mads Cj; Lund, Nunu Lt; Jensen, Rigmor H

    2017-03-01

    Purpose The purpose of this article is to investigate possible differences in effect between three types of masks in the acute treatment of cluster headache (CH). Patients and methods Fifty-seven CH patients according to ICHD-II-criteria participated in a single-blinded, semi-randomized, placebo-controlled, crossover inpatient study, and 102 CH attacks were treated with 100% oxygen delivered by demand valve oxygen (DVO), O 2 ptimask or simple mask (15 liters/min) or placebo delivered by DVO for 15 minutes. Primary endpoint: Two-point decrease of pain on a five-point rating scale within 15 minutes. Results Only 10 CH patients had multiple attacks and reached the point of placebo. There were no significant differences between masks in the primary endpoints ( p = 0.412). After 15 minutes 48% had a two-point decrease using the DVO compared to 45% with placebo ( p = 0.867). After 30 minutes 68% were pain free or had pain relief using DVO and 45% by placebo ( p = 0.061). The DVO was preferred by 62% compared to 5% and 33% for simple mask ( p < 0.0001) and O 2 ptimask ( p = 0.061). In the first attack the DVO was significantly better at achieving pain relief at 15 minutes ( p = 0.018). Treatment with DVO or O 2 ptimask reduced the need for rescue medication compared to the simple mask (23%, 19%, 50%, respectively). No treatment-related adverse events were observed. Conclusion The primary endpoint with pain relief at 15 minutes was non-significant; however, a post hoc analysis of the first attack significantly favored DVO. Further, therapy by O 2 ptimask and DVO resulted in a decreased need for rescue medication. We recommend that CH patients be offered DVO or O 2 ptimask before oxygen therapy is abandoned.

  8. Applications of CPL mask technology for sub-65nm gate imaging

    NASA Astrophysics Data System (ADS)

    Litt, Lloyd C.; Conley, Will; Wu, Wei; Peters, Richie; Parker, Colita; Cobb, Jonathan; Kasprowicz, Bryan S.; van den Broeke, Doug; Park, J. C.; Karur-Shanmugam, Ramkumar

    2005-05-01

    The requirements for critical dimension control on gate layer for high performance products are increasingly demanding. Phase shift techniques provide aerial image enhancement, which can translate into improved process window performance and greater critical dimension (CD) control if properly applied. Unfortunately, the application of hard shifter technology to production requires significant effort in layout and optical proximity correction (OPC) application. Chromeless Phase Lithography (CPL) has several advantages over complementary phase mask (c:PSM) such as use of a single mask, and lack of phase placement 'coloring' conflicts and phase imbalance issues. CPL does have implementation issues that must be resolved before it can be used in full-scale production. CPL mask designs can be approached by separating features into three zones based on several parameters, including size relative to the lithographic resolution of the stepper lens, wavelength, and illumination conditions defined. Features are placed into buckets for different treatment zones. Zone 1 features are constructed with 100% transmission phase shifted structures and Zone 3 features are chrome (binary) structures. Features that fall into Zone 2, which are too wide to be defined using the 100% transmission of pure CPL (i.e. have negative mask error factor, MEEF) are the most troublesome and can be approached in several ways. The authors have investigated the application of zebra structures of various sizes to product type layouts. Previous work to investigate CPL using test structures set the groundwork for the more difficult task of applying CPL rules to actual random logic design layouts, which include many zone transitions. Mask making limitations have been identified that play a role in the zebra sizing that can be applied to Zone 2 features. The elimination of Zone 2 regions was also investigated in an effort to simplify the application of CPL and improve manufacturability of reticle through data enhancements.

  9. Prognosis of white-coat and masked hypertension: International Database of HOme blood pressure in relation to Cardiovascular Outcome.

    PubMed

    Stergiou, George S; Asayama, Kei; Thijs, Lutgarde; Kollias, Anastasios; Niiranen, Teemu J; Hozawa, Atsushi; Boggia, José; Johansson, Jouni K; Ohkubo, Takayoshi; Tsuji, Ichiro; Jula, Antti M; Imai, Yutaka; Staessen, Jan A

    2014-04-01

    Home blood pressure monitoring is useful in detecting white-coat and masked hypertension and is recommended for patients with suspected or treated hypertension. The prognostic significance of white-coat and masked hypertension detected by home measurement was investigated in 6458 participants from 5 populations enrolled in the International Database of HOme blood pressure in relation to Cardiovascular Outcomes. During a median follow-up of 8.3 years, 714 fatal plus nonfatal cardiovascular events occurred. Among untreated subjects (n=5007), cardiovascular risk was higher in those with white-coat hypertension (adjusted hazard ratio 1.42; 95% CI [1.06-1.91]; P=0.02), masked hypertension (1.55; 95% CI [1.12-2.14]; P<0.01) and sustained hypertension (2.13; 95% CI [1.66-2.73]; P<0.0001) compared with normotensive subjects. Among treated patients (n=1451), the cardiovascular risk did not differ between those with high office and low home blood pressure (white-coat) and treated controlled subjects (low office and home blood pressure; 1.16; 95% CI [0.79-1.72]; P=0.45). However, treated subjects with masked hypertension (low office and high home blood pressure; 1.76; 95% CI [1.23-2.53]; P=0.002) and uncontrolled hypertension (high office and home blood pressure; 1.40; 95% CI [1.02-1.94]; P=0.04) had higher cardiovascular risk than treated controlled patients. In conclusion, white-coat hypertension assessed by home measurements is a cardiovascular risk factor in untreated but not in treated subjects probably because the latter receive effective treatment on the basis of their elevated office blood pressure. In contrast, masked uncontrolled hypertension is associated with increased cardiovascular risk in both untreated and treated patients, who are probably undertreated because of their low office blood pressure.

  10. Preclinical in vitro activity of QR-435 against influenza A virus as a virucide and in paper masks for prevention of viral transmission.

    PubMed

    Oxford, John S; Lambkin, Robert; Guralnik, Mario; Rosenbloom, Richard A; Petteruti, Michael P; Digian, Kelly; Lefante, Carolyn

    2007-01-01

    Prophylaxis against influenza is difficult, and current approaches against pandemics may be ineffective because of shortages of the two proven classes of antivirals in the face of a large-scale infection. Herbal/natural products may represent an effective alternative to conventional attempts to protect against infection by avian influenza virus. QR-435, an all-natural compound of green tea extract and other agents, has been developed to provide protection against a wide range of viral infections. The antiviral activities of several QR-435 preparations as well as QR-435 (1) green tea extract were tested against A/Sydney/5/97 and A/Panama-Resvir 17 strains of avian influenza virus H3N2 by means of an assay based on Madin-Darby canine kidney cells. Toxic effects of QR-435 formulations on these cells were also evaluated as were the virucidal properties of a commercially available mask impregnated with QR-435. The efficacy of a QR-435/mask combination was compared with that of the QR control/mask combination, an untreated mask, and no mask. QR-435 had significant in vitro activity against H3N2 at concentrations that were not associated with significant cellular toxic effects. The antiviral activity of QR-435 (1) was similar to that of QR-435. Masks impregnated with QR-435 were highly effective in blocking the passage of live H3N2 virus. These preclinical results warrant further evaluation of the prophylactic use of QR-435 against viral infection in humans.

  11. Phase-shifting coronagraph

    NASA Astrophysics Data System (ADS)

    Hénault, François; Carlotti, Alexis; Vérinaud, Christophe

    2017-09-01

    With the recent commissioning of ground instruments such as SPHERE or GPI and future space observatories like WFIRST-AFTA, coronagraphy should probably become the most efficient tool for identifying and characterizing extrasolar planets in the forthcoming years. Coronagraphic instruments such as Phase mask coronagraphs (PMC) are usually based on a phase mask or plate located at the telescope focal plane, spreading the starlight outside the diameter of a Lyot stop that blocks it. In this communication is investigated the capability of a PMC to act as a phase-shifting wavefront sensor for better control of the achieved star extinction ratio in presence of the coronagraphic mask. We discuss the two main implementations of the phase-shifting process, either introducing phase-shifts in a pupil plane and sensing intensity variations in an image plane, or reciprocally. Conceptual optical designs are described in both cases. Numerical simulations allow for better understanding of the performance and limitations of both options, and optimizing their fundamental parameters. In particular, they demonstrate that the phase-shifting process is a bit more efficient when implemented into an image plane, and is compatible with the most popular phase masks currently employed, i.e. fourquadrants and vortex phase masks.

  12. 24-month intervention with a specific multinutrient in people with prodromal Alzheimer's disease (LipiDiDiet): a randomised, double-blind, controlled trial.

    PubMed

    Soininen, Hilkka; Solomon, Alina; Visser, Pieter Jelle; Hendrix, Suzanne B; Blennow, Kaj; Kivipelto, Miia; Hartmann, Tobias

    2017-12-01

    Nutrition is an important modifiable risk factor in Alzheimer's disease. Previous trials of the multinutrient Fortasyn Connect showed benefits in mild Alzheimer's disease dementia. LipiDiDiet investigated the effects of Fortasyn Connect on cognition and related measures in prodromal Alzheimer's disease. Here, we report the 24-month results of the trial. LipiDiDiet was a 24-month randomised, controlled, double-blind, parallel-group, multicentre trial (11 sites in Finland, Germany, the Netherlands, and Sweden), with optional 12-month double-blind extensions. The trial enrolled individuals with prodromal Alzheimer's disease, defined according to the International Working Group (IWG)-1 criteria. Participants were randomly assigned (1:1) to active product (125 mL once-a-day drink containing Fortasyn Connect) or control product. Randomisation was computer-generated centrally in blocks of four, stratified by site. All study personnel and participants were masked to treatment assignment. The primary endpoint was change in a neuropsychological test battery (NTB) score. Analysis was by modified intention to treat. Safety analyses included all participants who consumed at least one study product dose. This trial is registered with the Dutch Trial Register, number NTR1705. Between April 20, 2009, and July 3, 2013, 311 of 382 participants screened were randomly assigned to the active group (n=153) or control group (n=158). Mean change in NTB primary endpoint was -0·028 (SD 0·453) in the active group and -0·108 (0·528) in the control group; estimated mean treatment difference was 0·098 (95% CI -0·041 to 0·237; p=0·166). The decline in the control group was less than the prestudy estimate of -0·4 during 24 months. 66 (21%) participants dropped out of the study. Serious adverse events occurred in 34 (22%) participants in the active group and 30 (19%) in control group (p=0·487), none of which were regarded as related to the study intervention. The intervention had no significant effect on the NTB primary endpoint over 2 years in prodromal Alzheimer's disease. However, cognitive decline in this population was much lower than expected, rendering the primary endpoint inadequately powered. Group differences on secondary endpoints of disease progression measuring cognition and function and hippocampal atrophy were observed. Further study of nutritional approaches with larger sample sizes, longer duration, or a primary endpoint more sensitive in this pre-dementia population, is needed. European Commission 7th Framework Programme. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  13. Odor Control Technology

    ERIC Educational Resources Information Center

    Turk, Amos; And Others

    1972-01-01

    Dispersion, chemical oxidation, and masking are reviewed as techniques primarily employed for odor control. Devices and systems, costs, and problems of measurement are considered in light of environmental agencies' efforts to curb smelly emissions. (BL)

  14. Comparing the Efficacy, Mask Leak, Patient Adherence, and Patient Preference of Three Different CPAP Interfaces to Treat Moderate-Severe Obstructive Sleep Apnea.

    PubMed

    Rowland, Sharn; Aiyappan, Vinod; Hennessy, Cathy; Catcheside, Peter; Chai-Coezter, Ching Li; McEvoy, R Doug; Antic, Nick A

    2018-01-15

    To determine if the type of continuous positive airway pressure (CPAP) mask interface influences CPAP treatment efficacy, adherence, side effects, comfort and sleep quality in patients with moderate-severe obstructive sleep apnea (OSA). This took place in a hospital-based tertiary sleep disorders unit. It is a prospective, randomized, crossover trial comparing three CPAP interfaces: nasal mask (NM), nasal mask plus chinstrap (NM-CS) and oronasal mask (ONM) each tried in random order, for 4 weeks. After each 4-week period, patient outcomes were assessed. Participants had a new diagnosis of obstructive sleep apneas. Forty-eight patients with moderate-severe OSA (32 males, mean ± standard deviation apnea-hypopnea index (AHI) 55.6 ± 21.1 events/h, age 54.9 ± 13.1 years, body mass index 35.8 ± 7.2 kg/m 2 ) were randomized. Thirty-five participants completed the full study, with complete data available for 34 patients. There was no statistically significant difference in CPAP adherence; however, residual AHI was higher with ONM than NM and NM-CS (residual AHI 7.1 ± 7.7, 4.0 ± 3.1, 4.2 ± 3.7 events/h respectively, main effect P = .001). Patient satisfaction and quality of sleep were higher with the NM and NM-CS than the ONM. Fewer leak and mask fit problems were reported with NM (all chi-square P < .05), which patients preferred over the NM-CS and ONM options (n = 22, 9 and 4 respectively, P = .001). The CPAP adherence did not differ between the three different mask interfaces but the residual AHI was lower with NM than ONM and patients reported greater mask comfort, better sleep, and overall preference for a NM. A nasal mask with or without chinstrap should be the first choice for patients with OSA referred for CPAP treatment. Registry: Australian and New Zealand Clinical Trials Registry, URL: https://www.anzctr.org.au, title: A comparison of continuous positive airway pressure (CPAP) interface in the control of leak, patient compliance and patient preference: nasal CPAP mask and chinstrap versus full face mask in patients with obstructive sleep apnoea (OSA), identifier: ACTRN12609000029291. © 2018 American Academy of Sleep Medicine

  15. Analgesic Effect of Topical Sodium Diclofenac before Retinal Photocoagulation for Diabetic Retinopathy: A Randomized Double-masked Placebo-controlled Intraindividual Crossover Clinical Trial.

    PubMed

    Ramezani, Alireza; Entezari, Morteza; Shahbazi, Mohammad Mehdi; Semnani, Yosef; Nikkhah, Homayoun; Yaseri, Mehdi

    2017-04-01

    To evaluate the analgesic effect of topical sodium diclofenac 0.1% before retinal laser photocoagulation for diabetic retinopathy. Diabetic patients who were candidates for peripheral laser photocoagulation were included in a randomized, placebo-controlled, intraindividual, two-period, and crossover clinical trial. At the first session and based on randomization, one eye received topical sodium diclofenac 0.1% and the other eye received an artificial tear drop (as placebo) three times before laser treatment. At the second session, eyes were given the alternate drug. Patients scored their pain using visual analogue scale (max, 10 cm) at both sessions. Patients and the surgeon were blinded to the drops given. Difference of pain level was the main outcome measure. A total of 200 eyes of 100 patients were enrolled. Both treatments were matched regarding the applied laser. Pain sensation based on visual analogue scale was 5.6 ± 3.0 in the treated group and 5.5 ± 3.0 in the control group. The calculated treatment effect was 0.15 (95% confidence interval, -0.27 to 0.58; p = 0.486). The estimated period effect was 0.24 ( p = 0.530) and the carryover effect was not significant ( p = 0.283). Pretreatment with topical sodium diclofenac 0.1% does not have any analgesic effect during peripheral retinal laser photocoagulation in diabetic patients.

  16. Tolerance of young infants to a single, large dose of vitamin A: a randomized community trial in Nepal.

    PubMed

    West, K P; Khatry, S K; LeClerq, S C; Adhikari, R; See, L; Katz, J; Shrestha, S R; Pradhan, E K; Pokhrel, R P; Sommer, A

    1992-01-01

    A randomized, double-masked trial was carried out in rural Nepal to investigate the incidence and severity of acute side-effects among neonates ( < 1 month of age) and infants aged 1-6 months who received a large, oral dose of vitamin A (15,000 retinol equivalents (RE) (50,000 IU) and 30,000 RE (100,000 IU), respectively) or placebo (75 RE (250 IU) and 150 RE (500 IU), respectively) in oil. Infants (vitamin A group, n = 1461; controls, n = 1379) were assessed for vomiting, loose stools, fever, and irritability during the 24 hours before and after dosing. Fontanelles were palpated 24 hours after dosing. Neonates exhibited no excess risk of adverse side-effects after receiving 15,000 RE. Compared with controls the older infants who ingested 30,000 RE had a 1.6% excess rate of vomiting (95% confidence interval (CI): 0.2-3.0%) and a 0.5% excess rate (95% CI: -0.1 to 1.1%) in the occurrence of bulging fontanelles. There were no other significant differences in the older infants. The controlled, periodic distribution of a single 15,000 RE dose of vitamin A therefore confers no apparent acute risk to young infants; a 30,000 RE dose is associated with a minimum risk of transient, acute side-effects.

  17. Double knockout of pendrin and Na-Cl cotransporter (NCC) causes severe salt wasting, volume depletion, and renal failure.

    PubMed

    Soleimani, Manoocher; Barone, Sharon; Xu, Jie; Shull, Gary E; Siddiqui, Faraz; Zahedi, Kamyar; Amlal, Hassane

    2012-08-14

    The Na-Cl cotransporter (NCC), which is the target of inhibition by thiazides, is located in close proximity to the chloride-absorbing transporter pendrin in the kidney distal nephron. Single deletion of pendrin or NCC does not cause salt wasting or excessive diuresis under basal conditions, raising the possibility that these transporters are predominantly active during salt depletion or in response to excess aldosterone. We hypothesized that pendrin and NCC compensate for loss of function of the other under basal conditions, thereby masking the role that each plays in salt absorption. To test our hypothesis, we generated pendrin/NCC double knockout (KO) mice by crossing pendrin KO mice with NCC KO mice. Pendrin/NCC double KO mice displayed severe salt wasting and sharp increase in urine output under basal conditions. As a result, animals developed profound volume depletion, renal failure, and metabolic alkalosis without hypokalemia, which were all corrected with salt replacement. We propose that the combined inhibition of pendrin and NCC can provide a strong diuretic regimen without causing hypokalemia for patients with fluid overload, including patients with congestive heart failure, nephrotic syndrome, diuretic resistance, or generalized edema.

  18. Detection of DNA double-strand breaks and chromosome translocations using ligation-mediated PCR and inverse PCR.

    PubMed

    Singh, Sheetal; Shih, Shyh-Jen; Vaughan, Andrew T M

    2014-01-01

    Current techniques for examining the global creation and repair of DNA double-strand breaks are restricted in their sensitivity, and such techniques mask any site-dependent variations in breakage and repair rate or fidelity. We present here a system for analyzing the fate of documented DNA breaks, using the MLL gene as an example, through application of ligation-mediated PCR. Here, a simple asymmetric double-stranded DNA adapter molecule is ligated to experimentally induced DNA breaks and subjected to seminested PCR using adapter- and gene-specific primers. The rate of appearance and loss of specific PCR products allows detection of both the break and its repair. Using the additional technique of inverse PCR, the presence of misrepaired products (translocations) can be detected at the same site, providing information on the fidelity of the ligation reaction in intact cells. Such techniques may be adapted for the analysis of DNA breaks and rearrangements introduced into any identifiable genomic location. We have also applied parallel sequencing for the high-throughput analysis of inverse PCR products to facilitate the unbiased recording of all rearrangements located at a specific genomic location.

  19. Double knockout of pendrin and Na-Cl cotransporter (NCC) causes severe salt wasting, volume depletion, and renal failure

    PubMed Central

    Soleimani, Manoocher; Barone, Sharon; Xu, Jie; Shull, Gary E.; Siddiqui, Faraz; Zahedi, Kamyar; Amlal, Hassane

    2012-01-01

    The Na-Cl cotransporter (NCC), which is the target of inhibition by thiazides, is located in close proximity to the chloride-absorbing transporter pendrin in the kidney distal nephron. Single deletion of pendrin or NCC does not cause salt wasting or excessive diuresis under basal conditions, raising the possibility that these transporters are predominantly active during salt depletion or in response to excess aldosterone. We hypothesized that pendrin and NCC compensate for loss of function of the other under basal conditions, thereby masking the role that each plays in salt absorption. To test our hypothesis, we generated pendrin/NCC double knockout (KO) mice by crossing pendrin KO mice with NCC KO mice. Pendrin/NCC double KO mice displayed severe salt wasting and sharp increase in urine output under basal conditions. As a result, animals developed profound volume depletion, renal failure, and metabolic alkalosis without hypokalemia, which were all corrected with salt replacement. We propose that the combined inhibition of pendrin and NCC can provide a strong diuretic regimen without causing hypokalemia for patients with fluid overload, including patients with congestive heart failure, nephrotic syndrome, diuretic resistance, or generalized edema. PMID:22847418

  20. Quality assessment and improvement of the EUMETSAT Meteosat Surface Albedo Climate Data Record

    NASA Astrophysics Data System (ADS)

    Lattanzio, A.; Fell, F.; Bennartz, R.; Trigo, I. F.; Schulz, J.

    2015-10-01

    Surface albedo has been identified as an important parameter for understanding and quantifying the Earth's radiation budget. EUMETSAT generated the Meteosat Surface Albedo (MSA) Climate Data Record (CDR) currently comprising up to 24 years (1982-2006) of continuous surface albedo coverage for large areas of the Earth. This CDR has been created within the Sustained, Coordinated Processing of Environmental Satellite Data for Climate Monitoring (SCOPE-CM) framework. The long-term consistency of the MSA CDR is high and meets the Global Climate Observing System (GCOS) stability requirements for desert reference sites. The limitation in quality due to non-removed clouds by the embedded cloud screening procedure is the most relevant weakness in the retrieval process. A twofold strategy is applied to efficiently improve the cloud detection and removal. The first step consists of the application of a robust and reliable cloud mask, taking advantage of the information contained in the measurements of the infrared and visible bands. Due to the limited information available from old radiometers, some clouds can still remain undetected. A second step relies on a post-processing analysis of the albedo seasonal variation together with the usage of a background albedo map in order to detect and screen out such outliers. The usage of a reliable cloud mask has a double effect. It enhances the number of high-quality retrievals for tropical forest areas sensed under low view angles and removes the most frequently unrealistic retrievals on similar surfaces sensed under high view angles. As expected, the usage of a cloud mask has a negligible impact on desert areas where clear conditions dominate. The exploitation of the albedo seasonal variation for cloud removal has good potentialities but it needs to be carefully addressed. Nevertheless it is shown that the inclusion of cloud masking and removal strategy is a key point for the generation of the next MSA CDR release.

  1. Comparative randomised controlled clinical trial of a herbal eye drop with artificial tear and placebo in computer vision syndrome.

    PubMed

    Biswas, N R; Nainiwal, S K; Das, G K; Langan, U; Dadeya, S C; Mongre, P K; Ravi, A K; Baidya, P

    2003-03-01

    A comparative randomised double masked multicentric clinical trial has been conducted to find out the efficacy and safety of a herbal eye drop preparation, itone eye drops with artificial tear and placebo in 120 patients with computer vision syndrome. Patients using computer for at least 2 hours continuosly per day having symptoms of irritation, foreign body sensation, watering, redness, headache, eyeache and signs of conjunctival congestion, mucous/debris, corneal filaments, corneal staining or lacrimal lake were included in this study. Every patient was instructed to put two drops of either herbal drugs or placebo or artificial tear in the eyes regularly four times for 6 weeks. Objective and subjective findings were recorded at bi-weekly intervals up to six weeks. Side-effects, if any, were also noted. In computer vision syndrome the herbal eye drop preparation was found significantly better than artificial tear (p < 0.01). No side-effects were noted by any of the drugs. Both subjective and objective improvements were observed in itone treated cases. So, itone can be considered as a useful drug in computer vision syndrome.

  2. Ocular response to hydrogen peroxide.

    PubMed

    Paugh, J R; Brennan, N A; Efron, N

    1988-02-01

    A controlled, randomized, double-masked study was conducted on eight human subjects to determine the threshold level of hydrogen peroxide, which is toxic when introduced into the eye via a high water content (75%; Durasoft 4) hydrogel contact lens. Subjective comfort, conjunctival hyperemia, corneal and conjunctival epithelial staining, and corneal oxygen uptake were assessed in response to 5-min wear of lenses that were presoaked in isotonic saline solutions of physiologic pH containing 0, 25, 50, 100, 200, 400, and 800 parts per million (ppm) hydrogen peroxide. Higher levels of hydrogen peroxide were associated with greater discomfort (p less than 0.05) and increased conjunctival hyperemia (p less than 0.001). The highest level of hydrogen peroxide tested (800 ppm) did not induce significant corneal or conjunctival epithelial staining or alter the corneal aerobic response. We conclude that residual concentrations of hydrogen peroxide in contact lens care systems should not exceed 100 ppm. Practitioners can use these data to estimate the level of residual hydrogen peroxide to which a patient may have been exposed upon lens application after neutralization.

  3. Debate on MERS-CoV respiratory precautions: surgical mask or N95 respirators?

    PubMed Central

    Chung, Jasmine Shimin; Ling, Moi Lin; Seto, Wing Hong; Ang, Brenda Sze Peng; Tambyah, Paul Anantharajah

    2014-01-01

    Since the emergence of Middle East respiratory syndrome coronavirus (MERS-CoV) in mid-2012, there has been controversy over the respiratory precaution recommendations in different guidelines from various international bodies. Our understanding of MERS-CoV is still evolving. Current recommendations on infection control practices are heavily influenced by the lessons learnt from severe acute respiratory syndrome. A debate on respiratory precautions for MERS-CoV was organised by Infection Control Association (Singapore) and the Society of Infectious Disease (Singapore). We herein discuss and present the evidence for surgical masks for the protection of healthcare workers from MERS-CoV. PMID:25017402

  4. Gender Differences in Neural Responses to Perceptually Invisible Fearful Face—An ERP Study

    PubMed Central

    Lee, Seung A.; Kim, Chai-Youn; Shim, Miseon; Lee, Seung-Hwan

    2017-01-01

    Women tend to respond to emotional stimuli differently from men. This study aimed at investigating whether neural responses to perceptually “invisible” emotional stimuli differ between men and women by exploiting event-related potential (ERP). Forty healthy participants (21 women) were recruited for the main experiment. A control experiment was conducted by excluding nine (7 women) participants from the main experiment and replacing them with additional ten (6 women) participants (total 41 participants) where Beck's Anxiety Inventory (BAI) and Beck's Depression Inventory (BDI) scores were controlled. Using the visual backward masking paradigm, either a fearful or a neutral face stimulus was presented in varied durations (subthreshold, near-threshold, or suprathreshold) followed by a mask. Participants performed a two-alternative forced choice (2-AFC) emotion discrimination task on each face. Behavioral analysis showed that participants were unaware of masked stimuli of which duration was the shortest and, therefore, processed at subthreshold. Nevertheless, women showed significantly larger response in P100 amplitude to subthreshold fearful faces than men. This result remained consistent in the control experiment. Our findings indicate gender-differences in neural response to subthreshold emotional face, which is reflected in the early processing stage. PMID:28184189

  5. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    PubMed Central

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F4,20  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. Conclusions: The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated. PMID:21062179

  6. Lactate signalling regulates fungal β-glucan masking and immune evasion

    PubMed Central

    Ballou, Elizabeth R.; Avelar, Gabriela M.; Childers, Delma S.; Mackie, Joanna; Bain, Judith M.; Wagener, Jeanette; Kastora, Stavroula L.; Panea, Mirela D.; Hardison, Sarah E.; Walker, Louise A.; Erwig, Lars P.; Munro, Carol A.; Gow, Neil A.R.; Brown, Gordon D.; MacCallum, Donna M.; Brown, Alistair J.P.

    2017-01-01

    Summary Paragraph As they proliferate, fungi expose antigens at their cell surface that are potent stimulators of the innate immune response, and yet the commensal fungus Candida albicans is able to colonize immuno-competent individuals. We show that C. albicans may evade immune detection by presenting a moving immunological target. We report that the exposure of β-glucan, a key Pathogen Associated Molecular Pattern (PAMP) located at the cell surface of C. albicans and other pathogenic Candida species, is modulated in response to changes in carbon source. Exposure to lactate induces β-glucan masking in C. albicans via a signaling pathway that has recruited an evolutionarily conserved receptor (Gpr1) and transcriptional factor (Crz1) from other well-characterized pathways. In response to lactate, these regulators control the expression of cell wall related genes that contribute to β-glucan masking. This represents the first description of active PAMP masking by a Candida species, a process that reduces the visibility of the fungus to the immune system. PMID:27941860

  7. Tradeoff between insensitivity to depth-induced spherical aberration and resolution of 3D fluorescence imaging due to the use of wavefront encoding with a radially symmetric phase mask

    NASA Astrophysics Data System (ADS)

    Doblas, Ana; Dutta, Ananya; Saavedra, Genaro; Preza, Chrysanthe

    2018-02-01

    Previously, a wavefront encoded (WFE) imaging system implemented using a squared cubic (SQUBIC) phase mask has been verified to reduce the sensitivity of the imaging system to spherical aberration (SA). The strength of the SQUBIC phase mask and, as consequence, the performance of the WFE system are controlled by a design parameter, A. Although the higher the A-value, the more tolerant the WFE system is to SA, this is accomplished at the expense of the effective imaging resolution. In this contribution, we investigate this tradeoff in order to find an optimal A-value to balance the effect of SA and loss of resolution.

  8. Regional brain activity during early visual perception in unaffected siblings of schizophrenia patients.

    PubMed

    Lee, Junghee; Cohen, Mark S; Engel, Stephen A; Glahn, David; Nuechterlein, Keith H; Wynn, Jonathan K; Green, Michael F

    2010-07-01

    Visual masking paradigms assess the early part of visual information processing, which may reflect vulnerability measures for schizophrenia. We examined the neural substrates of visual backward performance in unaffected sibling of schizophrenia patients using functional magnetic resonance imaging (fMRI). Twenty-one unaffected siblings of schizophrenia patients and 19 healthy controls performed a backward masking task and three functional localizer tasks to identify three visual processing regions of interest (ROI): lateral occipital complex (LO), the motion-sensitive area, and retinotopic areas. In the masking task, we systematically manipulated stimulus onset asynchronies (SOAs). We analyzed fMRI data in two complementary ways: 1) an ROI approach for three visual areas, and 2) a whole-brain analysis. The groups did not differ in behavioral performance. For ROI analysis, both groups increased activation as SOAs increased in LO. Groups did not differ in activation levels of the three ROIs. For whole-brain analysis, controls increased activation as a function of SOAs, compared with siblings in several regions (i.e., anterior cingulate cortex, posterior cingulate cortex, inferior prefrontal cortex, inferior parietal lobule). The study found: 1) area LO showed sensitivity to the masking effect in both groups; 2) siblings did not differ from controls in activation of LO; and 3) groups differed significantly in several brain regions outside visual processing areas that have been related to attentional or re-entrant processes. These findings suggest that LO dysfunction may be a disease indicator rather than a risk indicator for schizophrenia. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  9. Latanoprostene Bunod 0.024% in Subjects With Open-angle Glaucoma or Ocular Hypertension: Pooled Phase 3 Study Findings.

    PubMed

    Weinreb, Robert N; Liebmann, Jeffrey M; Martin, Keith R; Kaufman, Paul L; Vittitow, Jason L

    2018-01-01

    To compare the diurnal intraocular pressure (IOP)-lowering effect of latanoprostene bunod (LBN) 0.024% with timolol maleate 0.5% in subjects with open-angle glaucoma (OAG) or ocular hypertension (OHT). Pooled analysis of two phase 3, randomized, multicenter, double-masked, parallel-group, noninferiority trials (APOLLO and LUNAR), each with open-label safety extension phases. Adults with OAG or OHT were randomized 2:1 to double-masked treatment with LBN once daily (qd) or timolol twice daily (bid) for 3 months followed by open-label LBN treatment for 3 (LUNAR) or 9 (APOLLO) months. IOP was measured at 8 AM, 12 PM, and 4 PM at week 2, week 6, and months 3, 6, 9, and 12. Of the 840 subjects randomized, 774 (LBN, n=523; timolol crossover to LBN, n=251) completed the efficacy phase, and 738 completed the safety extension phase. Mean IOP was significantly lower with LBN versus timolol at all 9 evaluation timepoints during the efficacy phase (P<0.001). A significantly greater proportion of LBN-treated subjects attained a mean IOP ≤18 mm Hg and IOP reduction ≥25% from baseline versus timolol-treated subjects (P<0.001). The IOP reduction with LBN was sustained through the safety phase; subjects crossed over from timolol to LBN experienced additional significant IOP lowering (P≤0.009). Both treatments were well tolerated, and there were no safety concerns with long-term LBN treatment. In this pooled analysis of subjects with OAG and OHT, LBN 0.024% qd provided greater IOP-lowering compared with timolol 0.5% bid and maintained lowered IOP through 12 months. LBN demonstrated a safety profile comparable to that of prostaglandin analogs.

  10. Longitudinal comparison of outcomes after sub-Bowman keratomileusis and laser in situ keratomileusis: randomized, double-masked study.

    PubMed

    Wong, Rachel Chung Yin; Yu, Marco; Chan, Tommy C Y; Chong, Kelvin K L; Jhanji, Vishal

    2015-05-01

    To compare the outcomes of sub-Bowman keratomileusis (100-μm flap) and laser in situ keratomileusis (LASIK) (120-μm flap) using 150-kHz femtosecond laser. Randomized, double-masked, contralateral clinical trial. One hundred patients (200 eyes) with myopia or myopic astigmatism were included. Postoperative examinations were performed at week 1 and months 1, 3, 6, and 12. Main outcome measures included postoperative uncorrected (UCVA) and best-corrected distance visual acuity (BCVA); manifest refraction spherical equivalent; efficacy and safety indices; corneal thickness; and complications. The mean age of patients was 33.9 ± 7.9 years. Overall, the preoperative UCVA, BCVA, and manifest refraction spherical equivalent were 1.349 ± 0.332, -0.022 ± 0.033, and -5.81 ± 1.61 diopters, respectively. No significant difference was observed in preoperative (P ≥ .226) or intraoperative parameters (P ≥ .452) between both groups, except residual stromal thickness (P < .001). The UCVA, manifest refraction spherical equivalent, and central corneal thickness stabilized by 1 week, while the thinnest corneal thickness stabilized by 3 months postoperatively. There was no significant difference between both groups for any parameter during all follow-up visits (P ≥ .132) except the 3-month safety index, which was better in the sub-Bowman keratomileusis group (P = .007). Soft opaque bubble layer was noted intraoperatively in 12 cases (7, 100-μm group; 5, 120-μm group; P = .577). No postoperative complications were observed. Our study did not find any differences in the visual and refractive outcomes between femtosecond-assisted sub-Bowman keratomileusis and LASIK. Both surgeries resulted in quick visual recovery as early as 1 week postoperatively. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Tolerability of loteprednol/tobramycin versus dexamethasone/tobramycin in healthy volunteers: results of a 4-week, randomized, double-masked, parallel-group study.

    PubMed

    Bartlett, Jimmy D; Holland, Edward J; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L

    2008-08-01

    To compare the ocular comfort and tolerability of loteprednol etabonate 0.5%/tobramycin 0.3% (LE/T; Zylet) with dexamethasone 0.1%/tobramycin 0.3% (DM/T; TobraDex) in healthy volunteers. In this multicenter, randomized, double-masked, parallel-group study, healthy volunteers (n = 306) were randomized to receive LE/T or DM/T four times per day for 28 days. Subjects recorded subjective ratings for seven comfort/tolerability parameters using an electronic patient diary (EPD). The primary endpoint was the difference at week 4 from the ratings of an artificial tear at baseline in comfort/tolerability parameters between treatment groups, using a noninferiority paradigm. ClinicalTrials. gov, NCT 00532961. The 97.5% confidence intervals for the lower bound were within -10 for all of the seven comfort/ tolerability parameters evaluated (pain, stinging/burning, irritation, itchiness, foreign-body sensation, dryness, and light sensitivity). Secondary analysis revealed small but significant within-treatment differences in pain favoring LE/T over tears and in light sensitivity favoring tears over DM/T (p < 0.01). Small between-treatment differences in the changes from baseline tear ratings to individual study visits favored LE/T for pain, stinging/burning, irritation, itchiness, foreign-body sensation, and light sensitivity at visit 4 (p < or = 0.04); for pain, stinging/burning, and foreignbody sensation at visit 5 (p < or = 0.03), and for dryness and light sensitivity at visit 6 (p < or = 0.05). LE/T satisfied all conditions of noninferiority to DM/T in comfort and tolerability. Subjects receiving LE/T were more likely to report better ocular comfort/tolerability ratings relative to baseline artificial tears than subjects receiving DM/T. The study population consisted of healthy volunteers.

  12. Interaction of emitted sonar pulses and simulated echoes in a false killer whale: an evoked-potential study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2011-09-01

    Auditory evoked potentials (AEP) were recorded during echolocation in a false killer whale Pseudorca crassidens. An electronically synthesized and played-back (simulated) echo was triggered by an emitted biosonar pulse, and its intensity was proportional to that of the emitted click. The delay and transfer factor of the echo relative to the emitted click was controlled by the operator. The echo delay varied from 2 to 16 ms (by two-fold steps), and the transfer factor varied within ranges from -45 to -30 dB at the 2-ms delay to -60 to -45 dB at the 16-ms delay. Echo-related AEPs featured amplitude dependence both on echo delay at a constant transfer factor (the longer the delay, the higher amplitude) and on echo transfer factor at a constant delay (the higher transfer factor, the higher amplitude). Conjunctional variation of the echo transfer factor and delay kept the AEP amplitude constant when the delay to transfer factor trade was from -7.1 to -8.4 dB per delay doubling. The results confirm the hypothesis that partial forward masking of the echoes by the preceding emitted sonar pulses serves as a time-varying automatic gain control in the auditory system of echolocating odontocetes. © 2011 Acoustical Society of America

  13. Failure to preserve beta-cell function with mycophenolate mofetil and daclizumab combined therapy in patients with new- onset type 1 diabetes.

    PubMed

    Gottlieb, Peter A; Quinlan, Scott; Krause-Steinrauf, Heidi; Greenbaum, Carla J; Wilson, Darrell M; Rodriguez, Henry; Schatz, Desmond A; Moran, Antoinette M; Lachin, John M; Skyler, Jay S

    2010-04-01

    This trial tested whether mycophenolate mofetil (MMF) alone or with daclizumab (DZB) could arrest the loss of insulin-producing beta-cells in subjects with new-onset type 1 diabetes. A multi-center, randomized, placebo-controlled, double-masked trial was initiated by Type 1 Diabetes TrialNet at 13 sites in North America and Europe. Subjects diagnosed with type 1 diabetes and with sufficient C-peptide within 3 months of diagnosis were randomized to either MMF alone, MMF plus DZB, or placebo, and then followed for 2 years. The primary outcome was the geometric mean area under the curve (AUC) C-peptide from the 2-h mixed meal tolerance test. One hundred and twenty-six subjects were randomized and treated during the trial. The geometric mean C-peptide AUC at 2 years was unaffected by MMF alone or MMF plus DZB versus placebo. Adverse events were more frequent in the active therapy groups relative to the control group, but not significantly. Neither MMF alone nor MMF in combination with DZB had an effect on the loss of C-peptide in subjects with new-onset type 1 diabetes. Higher doses or more targeted immunotherapies may be needed to affect the autoimmune process.

  14. Failure to Preserve β-Cell Function With Mycophenolate Mofetil and Daclizumab Combined Therapy in Patients With New- Onset Type 1 Diabetes

    PubMed Central

    Gottlieb, Peter A.; Quinlan, Scott; Krause-Steinrauf, Heidi; Greenbaum, Carla J.; Wilson, Darrell M.; Rodriguez, Henry; Schatz, Desmond A.; Moran, Antoinette M.; Lachin, John M.; Skyler, Jay S.

    2010-01-01

    OBJECTIVE This trial tested whether mycophenolate mofetil (MMF) alone or with daclizumab (DZB) could arrest the loss of insulin-producing β-cells in subjects with new-onset type 1 diabetes. RESEARCH DESIGN AND METHODS A multi-center, randomized, placebo-controlled, double-masked trial was initiated by Type 1 Diabetes TrialNet at 13 sites in North America and Europe. Subjects diagnosed with type 1 diabetes and with sufficient C-peptide within 3 months of diagnosis were randomized to either MMF alone, MMF plus DZB, or placebo, and then followed for 2 years. The primary outcome was the geometric mean area under the curve (AUC) C-peptide from the 2-h mixed meal tolerance test. RESULTS One hundred and twenty-six subjects were randomized and treated during the trial. The geometric mean C-peptide AUC at 2 years was unaffected by MMF alone or MMF plus DZB versus placebo. Adverse events were more frequent in the active therapy groups relative to the control group, but not significantly. CONCLUSIONS Neither MMF alone nor MMF in combination with DZB had an effect on the loss of C-peptide in subjects with new-onset type 1 diabetes. Higher doses or more targeted immunotherapies may be needed to affect the autoimmune process. PMID:20067954

  15. Masking ability of a zirconia ceramic on composite resin substrate shades.

    PubMed

    Tabatabaian, Farhad; Shabani, Sima; Namdari, Mahshid; Sadeghpour, Koroush

    2017-01-01

    Masking ability of a restorative material plays an important role to cover discolored tooth structure; however, this ability has not yet been well understood in zirconia-based restorations. This study assessed the masking ability of a zirconia ceramic on composite resin substrates with different shades. Ten zirconia disc specimens, with 0.5 mm thickness and 10 mm diameter, were fabricated by a computer-aided design/computer-aided manufacturing system. A white substrate (control) and six composite resin substrates with different shades including A1, A2, A3, B2, C2, and D3 were prepared. The substrates had a cylindrical shape with 10 mm diameter and height. The specimens were placed onto the substrates for spectrophotometric evaluation. A spectrophotometer measured the L*, a*, and b* values for the specimens. ΔE values were calculated to determine the color differences between the groups and the control and then were compared with a perceptional threshold (ΔE = 2.6). Repeated measures ANOVA and Bonferroni tests were used for data analysis ( P < 0.05). The mean and standard deviation of ΔE values for A1, A2, A3, B2, C2, and D3 groups were 6.78 ± 1.59, 8.13 ± 1.66, 9.81 ± 2.64, 9.61 ± 1.38, 9.59 ± 2.63, and 8.13 ± 1.89, respectively. A significant difference was found among the groups in the ΔE values ( P = 0.006). The ΔE values were more than the perceptional threshold in all the groups ( P < 0.0001). Within the limitations of this study, it can be concluded that the tested zirconia ceramic could not thoroughly mask different shades of the composite resin substrates. Moreover, color masking of zirconia depends on the shade of substrate.

  16. Designing to win in sub-90nm mask production

    NASA Astrophysics Data System (ADS)

    Zhang, Yuan

    2005-11-01

    An informal survey conducted with key customers by Photronics indicates that the time gap between technology nodes has accelerated in recent years. Previously the cycle was three years. However, between 130nm and 90nm there was less than a 2 year gap, and between 90nm and 65nm a 1.5 year gap exists. As a result, the technical challenges have increased substantially. In addition, mask costs are rising exponentially due to high capital equipment cost, a shrinking customer base, long write times and increased applications of 193nm EAPSM or AAPSM. Collaboration among EDA companies, mask houses and wafer manufacturers is now more important than ever. This paper will explore avenues for reducing mask costs, mainly in the areas of: write-time reduction through design for manufacturing (DFM), and yield improvement through specification relaxation. Our study conducted through layout vertex modeling suggests that a simple design shape such as a square versus a circle or an angled structure helps reduce shot count and write time. Shot count reduction through mask layout optimization, and advancement in new generation E-beam writers can reduce write time up to 65%. An advanced laser writer can produce those less critical E-beam layers in less than half the time of an e-beam writer. Additionally, the emerging imprint lithography brings new life and new challenges to the photomask industry with applications in many fields outside of the semiconductor industry. As immersion lithography is introduced for 45nm device production, polarization and MEEF effects due to the mask will become severe. Larger magnification not only provides benefits on CD control and MEEF, but also extends the life time of current 90nm/65nm tool sets where 45nm mask sets can be produced at a lower cost.

  17. Nasal vs Oronasal CPAP for OSA Treatment: A Meta-Analysis.

    PubMed

    Andrade, Rafaela G S; Viana, Fernanda M; Nascimento, Juliana A; Drager, Luciano F; Moffa, Adriano; Brunoni, André R; Genta, Pedro R; Lorenzi-Filho, Geraldo

    2018-03-01

    Nasal CPAP is the "gold standard" treatment for OSA. However, oronasal masks are frequently used in clinical practice. The aim of this study was to perform a meta-analysis of all randomized and nonrandomized trials that compared nasal vs oronasal masks on CPAP level, residual apnea-hypopnea index (AHI), and CPAP adherence to treat OSA. The Cochrane Central Register of Controlled Trials, Medline, and Web of Science were searched for relevant studies in any language with the following terms: "sleep apnea" and "CPAP" or "sleep apnea" and "oronasal mask" or "OSA" and "oronasal CPAP" or "oronasal mask" and "adherence." Studies on CPAP treatment for OSA were included, based on the following criteria: (1) original article; (2) randomized or nonrandomized trials; and (3) comparison between nasal and oronasal CPAP including pressure level, and/or residual AHI, and/or CPAP adherence. We identified five randomized and eight nonrandomized trials (4,563 patients) that reported CPAP level and/or residual AHI and/or CPAP adherence. Overall, the random-effects meta-analysis revealed that as compared with nasal, oronasal masks were associated with a significantly higher CPAP level (Hedges' g, -0.59; 95% CI, -0.82 to -0.37; P < .001) (on average, +1.5 cm H 2 O), higher residual AHI (Hedges' g, -0.34; 95% CI, -0.52 to -0.17; P < .001) (+2.8 events/h), and a poorer adherence (Hedges' g, 0.50; 95% CI, 0.21-0.79; P = .001) (-48 min/night). Oronasal masks are associated with a higher CPAP level, higher residual AHI, and poorer adherence than nasal masks. PROSPERO database; No.: CRD42017064584; URL: https://www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  18. Past and future challenges from a display mask writer perspective

    NASA Astrophysics Data System (ADS)

    Ekberg, Peter; von Sydow, Axel

    2012-06-01

    Since its breakthrough, the liquid crystal technology has continued to gain momentum and the LCD is today the dominating display type used in desktop monitors, television sets, mobile phones as well as other mobile devices. To improve production efficiency and enable larger screen sizes, the LCD industry has step by step increased the size of the mother glass used in the LCD manufacturing process. Initially the mother glass was only around 0.1 m2 large, but with each generation the size has increased and with generation 10 the area reaches close to 10 m2. The increase in mother glass size has in turn led to an increase in the size of the photomasks used - currently the largest masks are around 1.6 × 1.8 meters. A key mask performance criterion is the absence of "mura" - small systematic errors captured only by the very sensitive human eye. To eliminate such systematic errors, special techniques have been developed by Micronic Mydata. Some mura suppressing techniques are described in this paper. Today, the race towards larger glass sizes has come to a halt and a new race - towards higher resolution and better image quality - is ongoing. The display mask is therefore going through a change that resembles what the semiconductor mask went through some time ago: OPC features are introduced, CD requirements are increasing sharply and multi tone masks (MTMs) are widely used. Supporting this development, Micronic Mydata has introduced a number of compensation methods in the writer, such as Z-correction, CD map and distortion control. In addition, Micronic Mydata MMS15000, the world's most precise large area metrology tool, has played an important role in improving mask placement quality and is briefly described in this paper. Furthermore, proposed specifications and system architecture concept for a new generation mask writers - able to fulfill future image quality requirements - is presented in this paper. This new system would use an AOD/AOM writing engine and be capable of resolving 0.6 micron features.

  19. Role of inhibition in the specification of orientation selectivity of cells in the cat striate cortex.

    PubMed

    Bonds, A B

    1989-01-01

    Mechanisms supporting orientation selectivity of cat striate cortical cells were studied by stimulation with two superimposed sine-wave gratings of different orientations. One grating (base) generated a discharge of known amplitude which could be modified by the second grating (mask). Masks presented at nonoptimal orientations usually reduced the base-generated response, but the degree of reduction varied widely between cells. Cells with narrow orientation tuning tended to be more susceptible to mask presence than broadly tuned cells; similarly, simple cells generally showed more response reduction than did complex cells. The base and mask stimuli were drifted at different temporal frequencies which, in simple cells, permitted the identification of individual response components from each stimulus. This revealed that the reduction of the base response by the mask usually did not vary regularly with mask orientation, although response facilitation from the mask was orientation selective. In some sharply tuned simple cells, response reduction had clear local maxima near the limits of the cell's orientation-tuning function. Response reduction resulted from a nearly pure rightward shift of the response versus log contrast function. The lowest mask contrast yielding reduction was within 0.1-0.3 log unit of the lowest contrast effective for excitation. The temporal-frequency bandpass of the response-reduction mechanism resembled that of most cortical cells. The spatial-frequency bandpass was much broader than is typical for single cortical cells, spanning essentially the entire visual range of the cat. These findings are compatible with a model in which weak intrinsic orientation-selective excitation is enhanced in two stages: (1) control of threshold by nonorientation-selective inhibition that is continuously dependent on stimulus contrast; and (2) in the more narrowly tuned cells, orientation-selective inhibition that has local maxima serving to increase the slope of the orientation-tuning function.

  20. A Randomized, Double-Masked, Placebo-Controlled Clinical Trial of Two Forms of Omega-3 Supplements for Treating Dry Eye Disease.

    PubMed

    Deinema, Laura A; Vingrys, Algis J; Wong, Chinn Yi; Jackson, David C; Chinnery, Holly R; Downie, Laura E

    2017-01-01

    To assess the efficacy of 2 forms of oral long-chain omega-3 (ω-3) essential fatty acid (EFA) supplements, phospholipid (krill oil) and triacylglyceride (fish oil), for treating dry eye disease (DED). Randomized, double-masked, placebo-controlled clinical trial. This study was conducted at a single site and involved 60 participants with mild to moderate DED who were randomized (1:1:1) to 1 of 3 groups: placebo (olive oil), krill oil, or fish oil supplements. Participants received 1 of the 3 interventions: placebo (olive oil 1500 mg/day), krill oil (945 mg/day eicosapentaenoic acid [EPA], + 510 mg/day docosahexaenoic acid [DHA]), or fish oil (1000 mg/day EPA + 500 mg/day DHA) for 90 days, with monthly study visits. Primary outcome measures were mean change in (1) tear osmolarity and (2) DED symptoms (Ocular Surface Disease Index [OSDI] score) between days 1 and 90. Secondary outcomes included mean change in key clinical signs (tear stability, tear production, ocular surface staining, bulbar and limbal redness, tear volume, anterior blepharitis, meibomian gland capping) and tear inflammatory cytokine levels. In total, 54 participants completed the study. At day 90, tear osmolarity was reduced from baseline with both krill oil (mean ± standard error of the mean: -18.6±4.5 mOsmol/l; n = 18; P < 0.001) and fish oil (-19.8±3.9 mOsmol/l; n = 19; P < 0.001) supplements, compared with placebo (-1.5±4.4 mOsmol/l; n = 17). OSDI score was significantly reduced at day 90 relative to baseline in the krill oil group only, compared with placebo (-18.6±2.4 vs. -10.5±3.3; P = 0.02). At day 90, there were also relative improvements in tear breakup time and ocular bulbar redness, compared with placebo, for both forms of ω-3 EFAs. Basal tear levels of the proinflammatory cytokine interleukin 17A were significantly reduced in the krill oil group, compared with placebo, at day 90 (-27.1±10.9 vs. 46.5±30.4 pg/ml; P = 0.02). A moderate daily dose of both forms of long-chain ω-3 EFAs, for 3 months, resulted in reduced tear osmolarity and increased tear stability in people with DED. Omega-3 EFAs in a predominantly phospholipid form (krill oil) may confer additional therapeutic benefit, with improvements in DED symptoms and lower basal tear levels of interleukin 17A, relative to placebo. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. Besifloxacin ophthalmic suspension 0.6% in patients with bacterial conjunctivitis: A multicenter, prospective, randomized, double-masked, vehicle-controlled, 5-day efficacy and safety study.

    PubMed

    Karpecki, Paul; Depaolis, Michael; Hunter, Judy A; White, Eric M; Rigel, Lee; Brunner, Lynne S; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L

    2009-03-01

    Besifloxacin ophthalmic suspension 0.6% is a new topical fluoroquinolone for the treatment of bacterial conjunctivitis. Besifloxacin has potent in vitro activity against a broad spectrum of ocular pathogens, including drug-resistant strains. The primary objective of this study was to compare the clinical and microbiologic efficacy of besifloxacin ophthalmic suspension 0.6% with that of vehicle (the formulation without besifloxacin) in the treatment of bacterial conjunctivitis. This was a multicenter, prospective, randomized, double-masked, vehicle-controlled, parallel-group study in patients with acute bacterial conjunctivitis. Patients received either topical besifloxacin ophthalmic suspension or vehicle administered 3 times daily for 5 days. At study entry and on days 4 and 8 (visits 2 and 3), a clinical assessment of ocular signs and symptoms was performed in both eyes, as well as pinhole visual acuity testing, biomicroscopy, and culture of the infected eye(s). An ophthalmoscopic examination was performed at study entry and on day 8. The primary efficacy outcome measures were clinical resolution and eradication of the baseline bacterial infection on day 8 in culture-confirmed patients. The safety evaluation included adverse events, changes in visual acuity, and biomicroscopy and ophthalmoscopy findings in all patients who received at least 1 dose of active treatment or vehicle. The safety population consisted of 269 patients (mean [SD] age, 34.2 [22.3] years; 60.2% female; 82.5% white) with acute bacterial conjunctivitis. The culture-confirmed intent-to-treat population consisted of 118 patients (60 besifloxacin ophthalmic suspension, 58 vehicle). Significantly more patients receiving besifloxacin ophthalmic suspension than vehicle had clinical resolution of the baseline infection at visit 3 (44/60 [73.3%] vs 25/58 [43.1%], respectively; P < 0.001). Rates of bacterial eradication also were significantly greater with besifloxacin ophthalmic suspension compared with vehicle at visit 3 (53/60 [88.3%] vs35/58 [60.3%]; P < 0.001). The cumulative frequency of adverse events did not differ significantly between the 2 groups (69/137 [50.4%] and 70/132 [53.0%]). The most common ocular adverse events were eye pain (20/190 treated eyes [10.5%] and 13/188 [6.9%]), blurred vision (20/190 [10.5%] and 22/188 [11.7%]), and eye irritation (14/190 [7.4%] and 23/188 [12.2%]); these events were of mild or moderate severity. Changes in visual acuity and treatment-emergent events observed on biomicroscopy and direct ophthalmoscopy also were comparable between treatment groups. Besifloxacin ophthalmic suspension 0.6% given 3 times daily for 5 days was both efficacious and well tolerated compared with vehicle in the treatment of these patients with bacterial conjunctivitis. ClinicalTrials.gov Identifier: NCT00622908.

  2. Adjunctive rifampicin for Staphylococcus aureus bacteraemia (ARREST): a multicentre, randomised, double-blind, placebo-controlled trial.

    PubMed

    Thwaites, Guy E; Scarborough, Matthew; Szubert, Alexander; Nsutebu, Emmanuel; Tilley, Robert; Greig, Julia; Wyllie, Sarah A; Wilson, Peter; Auckland, Cressida; Cairns, Janet; Ward, Denise; Lal, Pankaj; Guleri, Achyut; Jenkins, Neil; Sutton, Julian; Wiselka, Martin; Armando, Gonzalez-Ruiz; Graham, Clive; Chadwick, Paul R; Barlow, Gavin; Gordon, N Claire; Young, Bernadette; Meisner, Sarah; McWhinney, Paul; Price, David A; Harvey, David; Nayar, Deepa; Jeyaratnam, Dakshika; Planche, Tim; Minton, Jane; Hudson, Fleur; Hopkins, Susan; Williams, John; Török, M Estee; Llewelyn, Martin J; Edgeworth, Jonathan D; Walker, A Sarah

    2018-02-17

    Staphylococcus aureus bacteraemia is a common cause of severe community-acquired and hospital-acquired infection worldwide. We tested the hypothesis that adjunctive rifampicin would reduce bacteriologically confirmed treatment failure or disease recurrence, or death, by enhancing early S aureus killing, sterilising infected foci and blood faster, and reducing risks of dissemination and metastatic infection. In this multicentre, randomised, double-blind, placebo-controlled trial, adults (≥18 years) with S aureus bacteraemia who had received ≤96 h of active antibiotic therapy were recruited from 29 UK hospitals. Patients were randomly assigned (1:1) via a computer-generated sequential randomisation list to receive 2 weeks of adjunctive rifampicin (600 mg or 900 mg per day according to weight, oral or intravenous) versus identical placebo, together with standard antibiotic therapy. Randomisation was stratified by centre. Patients, investigators, and those caring for the patients were masked to group allocation. The primary outcome was time to bacteriologically confirmed treatment failure or disease recurrence, or death (all-cause), from randomisation to 12 weeks, adjudicated by an independent review committee masked to the treatment. Analysis was intention to treat. This trial was registered, number ISRCTN37666216, and is closed to new participants. Between Dec 10, 2012, and Oct 25, 2016, 758 eligible participants were randomly assigned: 370 to rifampicin and 388 to placebo. 485 (64%) participants had community-acquired S aureus infections, and 132 (17%) had nosocomial S aureus infections. 47 (6%) had meticillin-resistant infections. 301 (40%) participants had an initial deep infection focus. Standard antibiotics were given for 29 (IQR 18-45) days; 619 (82%) participants received flucloxacillin. By week 12, 62 (17%) of participants who received rifampicin versus 71 (18%) who received placebo experienced treatment failure or disease recurrence, or died (absolute risk difference -1·4%, 95% CI -7·0 to 4·3; hazard ratio 0·96, 0·68-1·35, p=0·81). From randomisation to 12 weeks, no evidence of differences in serious (p=0·17) or grade 3-4 (p=0·36) adverse events were observed; however, 63 (17%) participants in the rifampicin group versus 39 (10%) in the placebo group had antibiotic or trial drug-modifying adverse events (p=0·004), and 24 (6%) versus six (2%) had drug interactions (p=0·0005). Adjunctive rifampicin provided no overall benefit over standard antibiotic therapy in adults with S aureus bacteraemia. UK National Institute for Health Research Health Technology Assessment. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  3. Integrase inhibitor versus protease inhibitor based regimen for HIV-1 infected women (WAVES): a randomised, controlled, double-blind, phase 3 study

    PubMed Central

    Squires, Kathleen; Kityo, Cissy; Hodder, Sally; Johnson, Margaret; Voronin, Evgeny; Hagins, Debbie; Avihingsanon, Anchalee; Koenig, Ellen; Jiang, Shuping; White, Kirsten; Cheng, Andrew; Szwarcberg, Javier; Cao, Huyen

    2018-01-01

    Summary Background Women are under-represented in HIV antiretroviral therapy (ART) studies. Guidelines for selection of ART as initial therapy in patients with HIV-1 infection do not contain sex-specific treatment. We aimed to assess the safety and efficacy of the single tablet integrase inhibitor regimen containing elvitegravir, cobicistat, emtricitabine, and tenofovir disoproxil fumarate compared with a boosted protease inhibitor regimen of ritonavir-boosted atazanavir with emtricitabine and tenofovir disoproxil fumarate. Methods In this international, randomised, controlled, double-blind, phase 3 study (Women AntiretroViral Efficacy and Safety study [WAVES]), we recruited treatment-naive HIV-infected women with an estimated creatinine clearance of 70 mL/min or higher from 80 centres in 11 countries. Women were randomly assigned (1:1) to receive elvitegravir, cobicistat, emtricitabine, and tenofovir disoproxil fumarate (integrase inhibitor regimen) or ritonavir-boosted atazanavir with emtricitabine and tenofovir disoproxil fumarate (protease inhibitor based regimen); regimens were masked with matching placebos. Randomisation was done by a computer-generated allocation sequence (block size four) and was stratified by HIV-1 RNA viral load and race. Investigators, patients, study staff, and those assessing outcomes were masked to treatment group. All participants who received one dose of study drug were included in the primary efficacy and safety analyses. The main outcome was the proportion of patients with plasma HIV-1 RNA less than 50 copies per mL at week 48 as defined by US Food and Drug Administration snapshot algorithm (prespecified non-inferiority margin of 12%). This study is registered with ClinicalTrials.gov, number NCT01705574. Findings Between Nov 28, 2012, and March 12, 2014, 575 women were enrolled. 289 were randomly assigned to receive the integrase inhibitor regimen and 286 to receive the protease inhibitor based regimen. 252 (87%) women in the integrase inhibitor group had plasma HIV-1 RNA less than 50 copies per mL at week 48 compared with 231 (81%) women in the protease inhibitor group (adjusted difference 6·5%; 95% CI 0·4–12·6). No participant had virological failure with resistance in the integrase inhibitor group compared with three participants ([1%]; all Met184Val/Ile) in the protease inhibitor group. 19 women in the protease inhibitor group discontinued because of adverse events compared with five in the integrase inhibitor group. Interpretation WAVES shows that clinical trials of ART regimens in global and diverse populations of treatment-naive women are possible. The findings support guidelines recommending integrase inhibitor based regimens in first-line antiretroviral therapy. PMID:27562742

  4. Preparation of polymer-blended quinine nanocomposite particles by spray drying and assessment of their instrumental bitterness-masking effect using a taste sensor.

    PubMed

    Taki, Moeko; Tagami, Tatsuaki; Ozeki, Tetsuya

    2017-05-01

    The development of taste-masking technologies for foods and drugs is essential because it would enable people to consume and receive healthy and therapeutic effect without distress. In the current study, in order to develop a novel method to prepare nanocomposite particles (microparticles containing bitter nanoparticles) in only one step, by using spray drying, a two-solution mixing nozzle-equipped spray dryer that we previously reported was used. The nanocomposite particles with or without poorly water-soluble polymers prepared using our spray-drying technique were characterized. (1) The organic solution containing quinine, a model of bitter compound and poorly water-soluble polymers and (2) sugar alcohol (mannitol) aqueous solution were separately flown in tubes and two solutions were spray dried through two-solution type spray nozzle to prepare polymer-blended quinine nanocomposite particles. Mean diameters of nanoparticles, taste-masking effect and dissolution rate of quinine were evaluated. The results of taste masking by taste sensor suggested that the polymer (Eudragit EPO, Eudragit S100 or Ethyl cellulose)-blended quinine nanocomposite particles exhibited marked masking of instrumental quinine bitterness compared with the quinine nanocomposite particles alone. Quinine nanocomposite formulations altered the quinine dissolution rate, indicating that they can control intestinal absorption of quinine. These results suggest that polymer-blended quinine composite particles prepared using our spray-drying technique are useful for masking bitter tastes in the field of food and pharmaceutical industry.

  5. Synchrotron Infrared Confocal Microspectroscopical Detection of Heterogeneity Within Chemically Modified Single Starch Granules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wetzel, D.; Shi, Y; Reffner, J

    This reports the first detection of chemical heterogeneity in octenyl succinic anhydride modified single starch granules using a Fourier transform infrared (FT-IR) microspectroscopical technique that combines diffraction-limited infrared microspectroscopy with a step size that is less than the mask projected spot size focused on the plane of the sample. The high spatial resolution was achieved with the combination of the application of a synchrotron infrared source and the confocal image plane masking system of the double-pass single-mask Continuum{reg_sign} infrared microscope. Starch from grains such as corn and wheat exists in granules. The size of the granules depends on the plantmore » producing the starch. Granules used in this study typically had a median size of 15 {micro}m. In the production of modified starch, an acid anhydride typically is reacted with OH groups of the starch polymer. The resulting esterification adds the ester carbonyl (1723 cm{sup -1}) organic functional group to the polymer and the hydrocarbon chain of the ester contributes to the CH{sub 2} stretching vibration to enhance the intensity of the 2927 cm{sup -1} band. Detection of the relative modifying population on a single granule was accomplished by ratioing the baseline adjusted peak area of the carbonyl functional group to that of a carbohydrate band. By stepping a confocally defined infrared beam as small as 5 {micro}m x 5 {micro}m across a starch granule 1 {micro}m at a time in both the x and y directions, the heterogeneity is detected with the highest possible spatial resolution.« less

  6. Impact of study oximeter masking algorithm on titration of oxygen therapy in the Canadian oxygen trial.

    PubMed

    Schmidt, Barbara; Roberts, Robin S; Whyte, Robin K; Asztalos, Elizabeth V; Poets, Christian; Rabi, Yacov; Solimano, Alfonso; Nelson, Harvey

    2014-10-01

    To compare oxygen saturations as displayed to caregivers on offset pulse oximeters in the 2 groups of the Canadian Oxygen Trial. In 5 double-blind randomized trials of oxygen saturation targeting, displayed saturations between 88% and 92% were offset by 3% above or below the true values but returned to true values below 84% and above 96%. During the transition, displayed values remained static at 96% in the lower and at 84% in the higher target group during a 3% change in true saturations. In contrast, displayed values changed rapidly from 88% to 84% in the lower and from 92% to 96% in the higher target group during a 1% change in true saturations. We plotted the distributions of median displayed saturations on days with >12 hours of supplemental oxygen in 1075 Canadian Oxygen Trial participants to reconstruct what caregivers observed at the bedside. The oximeter masking algorithm was associated with an increase in both stability and instability of displayed saturations that occurred during the transition between offset and true displayed values at opposite ends of the 2 target ranges. Caregivers maintained saturations at lower displayed values in the higher than in the lower target group. This differential management reduced the separation between the median true saturations in the 2 groups by approximately 3.5%. The design of the oximeter masking algorithm may have contributed to the smaller-than-expected separation between true saturations in the 2 study groups of recent saturation targeting trials in extremely preterm infants. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Feasibility of retinoids for the treatment of emphysema study.

    PubMed

    Roth, Michael D; Connett, John E; D'Armiento, Jeanine M; Foronjy, Robert F; Friedman, Paul J; Goldin, Jonathan G; Louis, Thomas A; Mao, Jenny T; Muindi, Josephia R; O'Connor, George T; Ramsdell, Joe W; Ries, Andrew L; Scharf, Steven M; Schluger, Neil W; Sciurba, Frank C; Skeans, Melissa A; Walter, Robert E; Wendt, Christine H; Wise, Robert A

    2006-11-01

    Retinoids promote alveolar septation in the developing lung and stimulate alveolar repair in some animal models of emphysema. One hundred forty-eight subjects with moderate-to-severe COPD and a primary component of emphysema, defined by diffusing capacity of the lung for carbon monoxide (Dlco) [37.1 +/- 12.0% of predicted] and CT density mask (38.5 +/- 12.8% of voxels <- 910 Hounsfield units) [mean +/- SD] were enrolled into a randomized, double-blind, feasibility study at five university hospitals. Participants received all-trans retinoic acid (ATRA) at either a low dose (LD) [1 mg/kg/d] or high dose (HD) [2 mg/kg/d], 13-cis retinoic acid (13-cRA) [1 mg/kg/d], or placebo for 6 months followed by a 3-month crossover period. No treatment was associated with an overall improvement in pulmonary function, CT density mask score, or health-related quality of life (QOL) at the end of 6 months. However, time-dependent changes in Dlco (initial decrease with delayed recovery) and St. George Respiratory Questionnaire (delayed improvement) were observed in the HD-ATRA cohort and correlated with plasma drug levels. In addition, 5 of 25 participants in the HD-ATRA group had delayed improvements in their CT scores that also related to ATRA levels. Retinoid-related side effects were common but generally mild. No definitive clinical benefits related to the administration of retinoids were observed in this feasibility study. However, time- and dose-dependent changes in Dlco, CT density mask score, and health-related QOL were observed in subjects treated with ATRA, suggesting the possibility of exposure-related biological activity that warrants further investigation.

  8. Acute tryptophan depletion attenuates conscious appraisal of social emotional signals in healthy female volunteers

    PubMed Central

    Gray, Marcus A.; Minati, Ludovico; Whale, Richard; Harrison, Neil A.; Critchley, Hugo D.

    2010-01-01

    Rationale Acute tryptophan depletion (ATD) decreases levels of central serotonin. ATD thus enables the cognitive effects of serotonin to be studied, with implications for the understanding of psychiatric conditions, including depression. Objective To determine the role of serotonin in conscious (explicit) and unconscious/incidental processing of emotional information. Materials and methods A randomized, double-blind, cross-over design was used with 15 healthy female participants. Subjective mood was recorded at baseline and after 4 h, when participants performed an explicit emotional face processing task, and a task eliciting unconscious processing of emotionally aversive and neutral images presented subliminally using backward masking. Results ATD was associated with a robust reduction in plasma tryptophan at 4 h but had no effect on mood or autonomic physiology. ATD was associated with significantly lower attractiveness ratings for happy faces and attenuation of intensity/arousal ratings of angry faces. ATD also reduced overall reaction times on the unconscious perception task, but there was no interaction with emotional content of masked stimuli. ATD did not affect breakthrough perception (accuracy in identification) of masked images. Conclusions ATD attenuates the attractiveness of positive faces and the negative intensity of threatening faces, suggesting that serotonin contributes specifically to the appraisal of the social salience of both positive and negative salient social emotional cues. We found no evidence that serotonin affects unconscious processing of negative emotional stimuli. These novel findings implicate serotonin in conscious aspects of active social and behavioural engagement and extend knowledge regarding the effects of ATD on emotional perception. PMID:20596858

  9. Variations in backward masking with different masking stimuli: II. The effects of spatially quantised masks in the light of local contour interaction, interchannel inhibition, perceptual retouch, and substitution theories.

    PubMed

    Bachmann, Talis; Luiga, Iiris; Põder, Endel

    2005-01-01

    In part I we showed that with spatially non-overlapping targets and masks both local metacontrast-like interactions and attentional processes are involved in backward masking. In this second part we extend the strategy of varying the contents of masks to pattern masking where targets and masks overlap in space, in order to compare different masking theories. Images of human faces were backward-masked by three types of spatially quantised masks (the same faces as targets, faces different from targets, and Gaussian noise with power spectra typical for faces). Configural characteristics, rather than the spectral content of the mask, predicted the extent of masking at relatively long stimulus onset asynchronies (SOAs). This poses difficulties for the theory of transient-on-sustained inhibition as the principal mechanism of masking and also for local contour interaction being a decisive factor in pattern masking. The scale of quantisation had no effect on the masking capacity of noise masks and a strong effect on the capacity of different-face masks. Also, the decrease of configural masking with an increase in the coarseness of the quantisation of the mask highlights ambiguities inherent in the re-entrance-based substitution theory of masking. Different masking theories cannot solve the problems of masking separately. They should be combined in order to create a complex, yet comprehensible mode of interaction for the different mechanisms involved in visual backward masking.

  10. Is a controlled randomised trial the non-plus-ultra design? A contribution to discussion on comparative, controlled, non-randomised trials.

    PubMed

    Gaus, Wilhelm; Muche, Rainer

    2013-05-01

    Clinical studies provide formalised experience for evidence-based medicine (EBM). Many people consider a controlled randomised trial (CRT, identical to a randomised controlled trial RCT) to be the non-plus-ultra design. However, CRTs also have limitations. The problem is not randomisation itself but informed consent for randomisation and masking of therapies according to today's legal and ethical standards. We do not want to de-rate CRTs, but we would like to contribute to the discussion on clinical research methodology. Informed consent to a CRT and masking of therapies plainly select patients. The excellent internal validity of CRTs can be counterbalanced by poor external validity, because internal and external validity act as antagonists. In a CRT, patients may feel like guinea pigs, this can decrease compliance, cause protocol violations, reduce self-healing properties, suppress unspecific therapeutic effects and possibly even modify specific efficacy. A control group (comparative study) is most important for the degree of evidence achieved by a trial. Study control by detailed protocol and good clinical practice (controlled study) is second in importance and randomisation and masking is third (thus the sequence CRT instead of RCT). Controlled non-randomised trials are just as ambitious and detailed as CRTs. We recommend clinicians and biometricians to take high quality controlled non-randomised trials into consideration more often. They combine good internal and external validity, better suit daily medical practice, show better patient compliance and fewer protocol violations, deliver estimators unbiased by alienated patients, and perhaps provide a clearer explanation of the achieved success. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Binaural sluggishness in the perception of tone sequences and speech in noise.

    PubMed

    Culling, J F; Colburn, H S

    2000-01-01

    The binaural system is well-known for its sluggish response to changes in the interaural parameters to which it is sensitive. Theories of binaural unmasking have suggested that detection of signals in noise is mediated by detection of differences in interaural correlation. If these theories are correct, improvements in the intelligibility of speech in favorable binaural conditions is most likely mediated by spectro-temporal variations in interaural correlation of the stimulus which mirror the spectro-temporal amplitude modulations of the speech. However, binaural sluggishness should limit the temporal resolution of the representation of speech recovered by this means. The present study tested this prediction in two ways. First, listeners' masked discrimination thresholds for ascending vs descending pure-tone arpeggios were measured as a function of rate of frequency change in the NoSo and NoSpi binaural configurations. Three-tone arpeggios were presented repeatedly and continuously for 1.6 s, masked by a 1.6-s burst of noise. In a two-interval task, listeners determined the interval in which the arpeggios were ascending. The results showed a binaural advantage of 12-14 dB for NoSpi at 3.3 arpeggios per s (arp/s), which reduced to 3-5 dB at 10.4 arp/s. This outcome confirmed that the discrimination of spectro-temporal patterns in noise is susceptible to the effects of binaural sluggishness. Second, listeners' masked speech-reception thresholds were measured in speech-shaped noise using speech which was 1, 1.5, and 2 times the original articulation rate. The articulation rate was increased using a phase-vocoder technique which increased all the modulation frequencies in the speech without altering its pitch. Speech-reception thresholds were, on average, 5.2 dB lower for the NoSpi than for the NoSo configuration, at the original articulation rate. This binaural masking release was reduced to 2.8 dB when the articulation rate was doubled, but the most notable effect was a 6-8 dB increase in thresholds with articulation rate for both configurations. These results suggest that higher modulation frequencies in masked signals cannot be temporally resolved by the binaural system, but that the useful modulation frequencies in speech are sufficiently low (<5 Hz) that they are invulnerable to the effects of binaural sluggishness, even at elevated articulation rates.

  12. Single closed contact for 0.18-micron photolithography process

    NASA Astrophysics Data System (ADS)

    Cheung, Cristina; Phan, Khoi A.; Chiu, Robert J.

    2000-06-01

    With the rapid advances of deep submicron semiconductor technology, identifying defects is converted into a challenge for different modules in the fabrication of chips. Yield engineers often do bitmap on a memory circuit array (SRAM) to identify the failure bits. This is followed by a wafer stripback to look for visual defects at each deprocessed layer for feedback to the Fab. However, to identify the root cause of a problem, Fab engineers must be able to detect similar defects either on the product wafers in process or some short loop test wafers. In the photolithography process, we recognize that the detection of defects is becoming as important as satisfying the critical dimension (CD) of the device. For a multi-level metallization chemically mechanical polish backend process, it is very difficult to detect missing contacts or via at the masking steps due to metal grain roughness, film color variation and/or previous layer defects. Often, photolithography engineer must depend on Photo Cell Monitor (PCM) and short loop experiments for controlling baseline defects and improvement. In this paper, we discuss the findings on the Poly mask PCM and the Contact mask PCM. We present the comparison between the Poly mask and the Contact mask of the I-line Phase Shifted Via mask and DUV mask process for a 0.18 micron process technology. The correlation and the different type of defects between the Contact PCM and the Poly Mask are discussed. The Contact PCM was found to be more sensitive and correlated to contact failure at sort yield better. We also dedicate to study the root cause of a single closed contact hole in the Contact mask short loop experiment for a 0.18 micron process technology. A single closed contact defect was often caused by the developer process, such as bubbles in the line, resist residue left behind, and the rinse mechanism. We also found surfactant solution helps to improve the surface tension of the wafer for the developer process and this prevents/eliminates a single closed contact hole defects. The applications and effects of using different substrates like SiON, different thicknesses of Oxides, and Poly in the Contact Photo Mask is shown. Finally, some defect troubleshooting techniques and the root cause analysis are also discussed.

  13. Imaging performance improvement of coherent extreme-ultraviolet scatterometry microscope with high-harmonic-generation extreme-ultraviolet source

    NASA Astrophysics Data System (ADS)

    Mamezaki, Daiki; Harada, Tetsuo; Nagata, Yutaka; Watanabe, Takeo

    2017-06-01

    In extreme-ultraviolet (EUV) lithography, the development of a review apparatus for the EUV mask pattern at an exposure wavelength of 13.5 nm is required. The EUV mask is composed of an absorber pattern and a Mo/Si multilayer on a glass substrate. This mask pattern has a three-dimensional (3D) structure. The 3D structure would modulate the EUV reflection phase, which would cause focus and pattern shifts. Thus, the review of the EUV phase image is also important. We have developed a coherent EUV scatterometry microscope (CSM), which is a simple microscope without objective optics. The EUV phase and intensity images were reconstructed with diffraction images by ptychography. For a standalone mask review, the high-harmonic-generation (HHG) EUV source was employed. In this study, we updated the sample stage, pump-laser reduction system, and gas-pressure control system to reconstruct the image. As a result, an 88 nm line-and-space pattern and a cross-line pattern were reconstructed. In addition, a particle defect of 2 µm diameter was well reconstructed. This demonstrated the high capability of the standalone CSM, which can hence be used in factories, such as mask shops and semiconductor fabrication plants.

  14. Benefits of using culturally unfamiliar stimuli in ambiguous emotion identification: A cross-cultural study.

    PubMed

    Koelkebeck, Katja; Kohl, Waldemar; Luettgenau, Julia; Triantafillou, Susanna; Ohrmann, Patricia; Satoh, Shinji; Minoshita, Seiko

    2015-07-30

    A novel emotion recognition task that employs photos of a Japanese mask representing a highly ambiguous stimulus was evaluated. As non-Asians perceive and/or label emotions differently from Asians, we aimed to identify patterns of task-performance in non-Asian healthy volunteers with a view to future patient studies. The Noh mask test was presented to 42 adult German participants. Reaction times and emotion attribution patterns were recorded. To control for emotion identification abilities, a standard emotion recognition task was used among others. Questionnaires assessed personality traits. Finally, results were compared to age- and gender-matched Japanese volunteers. Compared to other tasks, German participants displayed slowest reaction times on the Noh mask test, indicating higher demands of ambiguous emotion recognition. They assigned more positive emotions to the mask than Japanese volunteers, demonstrating culture-dependent emotion identification patterns. As alexithymic and anxious traits were associated with slower reaction times, personality dimensions impacted on performance, as well. We showed an advantage of ambiguous over conventional emotion recognition tasks. Moreover, we determined emotion identification patterns in Western individuals impacted by personality dimensions, suggesting performance differences in clinical samples. Due to its properties, the Noh mask test represents a promising tool in the differential diagnosis of psychiatric disorders, e.g. schizophrenia. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. What's in a mask? Information masking with forward and backward visual masks.

    PubMed

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  16. In search of multipath interference using large molecules

    PubMed Central

    Cotter, Joseph P.; Brand, Christian; Knobloch, Christian; Lilach, Yigal; Cheshnovsky, Ori; Arndt, Markus

    2017-01-01

    The superposition principle is fundamental to the quantum description of both light and matter. Recently, a number of experiments have sought to directly test this principle using coherent light, single photons, and nuclear spin states. We extend these experiments to massive particles for the first time. We compare the interference patterns arising from a beam of large dye molecules diffracting at single, double, and triple slit material masks to place limits on any high-order, or multipath, contributions. We observe an upper bound of less than one particle in a hundred deviating from the expectations of quantum mechanics over a broad range of transverse momenta and de Broglie wavelength. PMID:28819641

  17. Posthypnotic suggestion alters conscious color perception in an automatic manner.

    PubMed

    Kallio, Sakari; Koivisto, Mika

    2013-01-01

    The authors studied whether a posthypnotic suggestion to see a brief, masked target as gray can change the color experience of a hypnotic virtuoso. The visibility of the target was manipulated by varying the delay between the target and the mask that followed it. The virtuoso's subjective reports indicated that her conscious color experience was altered already at short delays between the target and the subsequent mask. The virtuoso's objectively measured pattern of responding under posthypnotic suggestion could not be mimicked either by control participants nor the virtuoso herself. Due to posthypnotic amnesia, the virtuoso was unaware of suggestions given during hypnosis. Importantly, the virtuoso could not alter her color perception without a hypnotic suggestion. These results suggest that hypnosis can affect even a highly automatic process such as color perception.

  18. Fabrication of sub-12 nm thick silicon nanowires by processing scanning probe lithography masks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyoung Ryu, Yu; Garcia, Ricardo, E-mail: r.garcia@csic.es; Aitor Postigo, Pablo

    2014-06-02

    Silicon nanowires are key elements to fabricate very sensitive mechanical and electronic devices. We provide a method to fabricate sub-12 nm silicon nanowires in thickness by combining oxidation scanning probe lithography and anisotropic dry etching. Extremely thin oxide masks (0.3–1.1 nm) are transferred into nanowires of 2–12 nm in thickness. The width ratio between the mask and the silicon nanowire is close to one which implies that the nanowire width is controlled by the feature size of the nanolithography. This method enables the fabrication of very small single silicon nanowires with cross-sections below 100 nm{sup 2}. Those values are the smallest obtained withmore » a top-down lithography method.« less

  19. Etching nano-holes in silicon carbide using catalytic platinum nano-particles

    NASA Astrophysics Data System (ADS)

    Moyen, E.; Wulfhekel, W.; Lee, W.; Leycuras, A.; Nielsch, K.; Gösele, U.; Hanbücken, M.

    2006-09-01

    The catalytic reaction of platinum during a hydrogen etching process has been used to perform controlled vertical nanopatterning of silicon carbide substrates. A first set of experiments was performed with platinum powder randomly distributed on the SiC surface. Subsequent hydrogen etching in a hot wall reactor caused local atomic hydrogen production at the catalyst resulting in local SiC etching and hole formation. Secondly, a highly regular and monosized distribution of Pt was obtained by sputter deposition of Pt through an Au membrane serving as a contact mask. After the lift-off of the mask, the hydrogen etching revealed the onset of well-controlled vertical patterned holes on the SiC surface.

  20. A Novel Catalyst Deposition Technique for the Growth of Carbon Nanotubes

    NASA Technical Reports Server (NTRS)

    Delzeit, Lance; Cassell, A.; Stevens, R.; Nguyen, C.; Meyyappan, M.; DeVincenzi, Donald L. (Technical Monitor)

    2001-01-01

    This viewgraph presentation provides information on the development of a technique at NASA's Ames Research Center by which carbon nanotubes (NT) can be grown. The project had several goals which included: 1) scaleability, 2) ability to control single wall nanotube (SWNT) and multiwall nanotube (MWNT) formation, 3) ability to control the density of nanotubes as they grow, 4) ability to apply standard masking techniques for NT patterning. Information regarding the growth technique includes its use of a catalyst deposition process. SWNTs of varying thicknesses can be grown by changing the catalyst composition. Demonstrations are given of various methods of masking including the use of transmission electron microscopic (TEM) grids.

Top