Fatigue data for polyether ether ketone (PEEK) under fully-reversed cyclic loading
Shrestha, Rakish; Simsiriwong, Jutima; Shamsaei, Nima
2016-01-01
In this article, the data obtained from the uniaxial fully-reversed fatigue experiments conducted on polyether ether ketone (PEEK), a semi-crystalline thermoplastic, are presented. The tests were performed in either strain-controlled or load-controlled mode under various levels of loading. The data are categorized into four subsets according to the type of tests, including (1) strain-controlled fatigue tests with adjusted frequency to obtain the nominal temperature rise of the specimen surface, (2) strain-controlled fatigue tests with various frequencies, (3) load-controlled fatigue tests without step loadings, and (4) load-controlled fatigue tests with step loadings. Accompanied data for each test include the fatigue life, the maximum (peak) and minimum (valley) stress–strain responses for each cycle, and the hysteresis stress–strain responses for each collected cycle in a logarithmic increment. A brief description of the experimental method is also given. PMID:26937465
Fatigue data for polyether ether ketone (PEEK) under fully-reversed cyclic loading.
Shrestha, Rakish; Simsiriwong, Jutima; Shamsaei, Nima
2016-03-01
In this article, the data obtained from the uniaxial fully-reversed fatigue experiments conducted on polyether ether ketone (PEEK), a semi-crystalline thermoplastic, are presented. The tests were performed in either strain-controlled or load-controlled mode under various levels of loading. The data are categorized into four subsets according to the type of tests, including (1) strain-controlled fatigue tests with adjusted frequency to obtain the nominal temperature rise of the specimen surface, (2) strain-controlled fatigue tests with various frequencies, (3) load-controlled fatigue tests without step loadings, and (4) load-controlled fatigue tests with step loadings. Accompanied data for each test include the fatigue life, the maximum (peak) and minimum (valley) stress-strain responses for each cycle, and the hysteresis stress-strain responses for each collected cycle in a logarithmic increment. A brief description of the experimental method is also given.
Strain-controlled fatigue of acrylic bone cement.
Carter, D R; Gates, E I; Harris, W H
1982-09-01
Monotonic tensile tests and tension-compression fatigue tests were conducted of wet acrylic bone cement specimens at 37 degrees C. All testing was conducted in strain control at a strain rate of 0.02/s. Weibull analysis of the tensile tests indicated that monotonic fracture was governed more strongly by strain than stress. The number of cycles to fatigue failure was also more strongly controlled by strain amplitude than stress amplitude. Specimen porosity distribution played a major role in determining the tensile and fatigue strengths. The degree of data scatter suggests that Weibull analysis of fatigue data may be useful in developing design criteria for the surgical use of bone cement.
NASA Astrophysics Data System (ADS)
Yonekawa, M.; Ishii, T.; Ohmi, M.; Takada, F.; Hoshiya, T.; Niimi, M.; Ioka, I.; Miwa, Y.; Tsuji, H.
2002-12-01
In order to investigate effects of neutron irradiation on fatigue properties of nuclear materials, a remote-controlled high temperature fatigue test machine was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR) in the Japan Atomic Energy Research Institute (JAERI). A small-sized fatigue specimen having double blades to measure strain with a laser extensometer was designed for this machine. A strain amplitude in fatigue tests of a completely reversed push-pull type using a triangular wave was controlled with an accuracy of ±3% of the total strain range during test. Low cycle fatigue tests of type 304 stainless steel irradiated in JMTR at 823 K up to a fast neutron fluence of 1×10 25 n/m 2 ( E>1 MeV) were performed in total strain ranges of 0.7-1.4% at 823 K using the designed small-sized specimens.
Notched fatigue of single crystal PWA 1480 at turbine attachment temperatures
NASA Technical Reports Server (NTRS)
Meyer, T. G.; Nissley, D. M.; Swanson, G. A.
1989-01-01
The focus is on the lower temperature, uncoated and notched features of gas turbine blades. Constitutive and fatigue life prediction models applicable to these regions are being developed. Fatigue results are presented which were obtained thus far. Fatigue tests are being conducted on PWA 1480 single crystal material using smooth strain controlled specimens and three different notched specimens. Isothermal fatigue tests were conducted at 1200, 1400, and 1600 F. The bulk of the tests were conducted at 1200 F. The strain controlled tests were conducted at 0.4 percent per second strain rate and the notched tests were cycled at 1.0 cycle per second. A clear orientation dependence is observed in the smooth strain controlled fatigue results. The fatigue lifes of the thin, mild notched specimens agree fairly well with this smooth data when elastic stress range is used as a correlating parameter. Finite element analyses were used to calculate notch stresses. Fatigue testing will continue to further explore the trends observed thus far. Constitutive and life prediction models are being developed.
Fatigue Life Estimation under Cumulative Cyclic Loading Conditions
NASA Technical Reports Server (NTRS)
Kalluri, Sreeramesh; McGaw, Michael A; Halford, Gary R.
1999-01-01
The cumulative fatigue behavior of a cobalt-base superalloy, Haynes 188 was investigated at 760 C in air. Initially strain-controlled tests were conducted on solid cylindrical gauge section specimens of Haynes 188 under fully-reversed, tensile and compressive mean strain-controlled fatigue tests. Fatigue data from these tests were used to establish the baseline fatigue behavior of the alloy with 1) a total strain range type fatigue life relation and 2) the Smith-Wastson-Topper (SWT) parameter. Subsequently, two load-level multi-block fatigue tests were conducted on similar specimens of Haynes 188 at the same temperature. Fatigue lives of the multi-block tests were estimated with 1) the Linear Damage Rule (LDR) and 2) the nonlinear Damage Curve Approach (DCA) both with and without the consideration of mean stresses generated during the cumulative fatigue tests. Fatigue life predictions by the nonlinear DCA were much closer to the experimentally observed lives than those obtained by the LDR. In the presence of mean stresses, the SWT parameter estimated the fatigue lives more accurately under tensile conditions than under compressive conditions.
Dailey, Dana L; Keffala, Valerie J; Sluka, Kathleen A
2014-01-01
Objective Fibromyalgia is a condition characterized by chronic widespread muscle pain and fatigue. The primary objective of this study was to determine if pain, perceived cognitive fatigue, and perceived physical fatigue were enhanced in participants with fibromyalgia compared to healthy controls during a cognitive fatigue task, a physical fatigue task and a dual fatigue task. Methods Twenty four people with fibromyalgia and 33 healthy controls completed pain, fatigue and function measures. A cognitive fatigue task (Controlled Oral Word Association Test) and physical fatigue task (Valpar peg test) were done individually and combined for a dual fatigue task. Resting pain, perceived cognitive fatigue and perceived physical fatigue were assessed during each task using visual analogue scales. Function was assessed with shoulder range of motion and grip. Results People with fibromyalgia had significantly higher increases in pain, cognitive fatigue and physical fatigue when compared to healthy controls after completion of a cognitive fatigue task, a physical fatigue task, or a dual fatigue task (p<0.01). People with fibromyalgia performed equivalently on measures of physical performance and cognitive performance on the physical and cognitive fatigue tasks, respectively. Conclusions These data show that people with fibromyalgia show larger increases in pain, perceived cognitive fatigue and perceived physical fatigue to both cognitive and physical fatigue tasks compared to healthy controls. The increases in pain and fatigue during cognitive and physical fatigue tasks could influence subject participation in daily activities and rehabilitation. PMID:25074583
Fatigue Characterization of Alloy 10: a 1300F Disk Alloy for Small Gas Turbine Engines
NASA Technical Reports Server (NTRS)
Gayda, John
2000-01-01
A detailed fatigue characterization of Alloy 10, a high strength nickel-based disk alloy, was conducted on test coupons machined from a 'pancake' forging. Smooth bar, strain controlled fatigue testing at various R-ratios was run at representative bore, 750 F, and rim, 1300 F, temperatures. This was followed by notch fatigue testing (Kt=2) run under load control. Analysis of the fatigue data using a Smith-Watson-Topper approach and finite element analysis of the notch root was employed to understand material behavior in these tests. Smooth bar fatigue data showed a significant R-ratio dependence at either test temperature which could be accounted for using a Smith-Watson-Topper parameter (SWT). In general, fatigue life was longer at 750 F than 1300 F for a given SWT. For notch fatigue tests, life was longer at 750 F than 1300 F but only at higher stresses. This was attributed to differences in alloy strength. At lower stresses, finite element analysis suggested that convergence of fatigue life at both temperatures resulted from relaxation of stresses at the notch root in the 1300 F tests.
Tension and fatigue behavior of 316LVM 1x7 multi-strand cables used as implantable electrodes.
Lewandowski, John J; Varadarajan, Ravikumar; Smith, Brian; Tuma, Chris; Shazly, Mostafa; Vatamanu, Luciano O
2008-07-15
The mechanical behavior of 316LVM 1x7 cables were evaluated in uniaxial tension, and in cyclic strain-controlled fatigue with the use of a Flex tester operated to provide fully reversed bending fatigue. The magnitude of cyclic strains imparted to each cable tested was controlled via the use of different diameter mandrels. Smaller diameter mandrels produced higher values of cyclic strain and lower fatigue life. Multiple samples were tested and analyzed via scanning electron microscopy. The fatigue results were analyzed via a Coffin-Manson-Basquin approach and compared to fatigue data obtained from the literature where testing was conducted on similar materials, but under rotating bending fatigue conditions.
Evaluating cyclic fatigue of sealants during outdoor testing
R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White
2009-01-01
A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...
NASA Technical Reports Server (NTRS)
Conway, J. B.; Stentz, R. H.; Berling, J. T.
1976-01-01
Low-cycle fatigue tests of 1/2 Hard AMZIRC Copper and NARloy Z were performed in argon at 538 C to determine partitioned strain range versus life relationships. Strain-controlled low-cycle fatigue tests of a Zr-Cr-Mg copper-base alloy were also performed. Strain ranges, lower than those employed in previous tests, were imposed in order to extend the fatigue life curve out to approximately 400,000 cycles. An experimental copper alloy and an experimental silver alloy were also studied. Tensile tests were performed in air at room temperature and in argon at 538 C. Strain-controlled low-cycle fatigue tests were performed at 538 C in argon to define the fatigue life over the regime from 300 to 3,000 cycles. For the silver alloy, three additional heat treatments were introduced, and a limited evaluation of the short-term tensile and low-cycle fatigue behavior at 538 C was performed.
Xu, L; Fan, S; Cai, B; Fang, Z; Jiang, X
2017-05-01
This study aimed to investigate whether the fatigue induced by sustained motor task in the jaw elevator muscles differed between healthy subjects and patients with temporomandibular disorder (TMD). Fifteen patients with TMD and thirteen age- and sex-matched healthy controls performed a fatigue test consisting of sustained clenching contractions at 30% maximal voluntary clenching intensity until test failure (the criterion for terminating the fatigue test was when the biting force decreased by 10% or more from the target force consecutively for >3 s). The pre- and post-maximal bite forces (MBFs) were measured. Surface electromyographic signals were recorded from the superficial masseter muscles and anterior temporal muscles bilaterally, and the median frequency at the beginning, middle and end of the fatigue test was calculated. The duration of the fatigue test was also quantified. Both pre- and post-MBFs were lower in patients with TMD than in controls (P < 0·01). No significant difference was found in the percentage change in MBF between groups. The duration of the fatigue test in TMD patients was significantly shorter than that of the controls (P < 0·05). Our results suggest that, compared to healthy subjects, patients with TMD become more easily fatigued, but the electromyographic activation process during the fatigue test is similar between healthy subjects and patients with TMD. However, the mechanisms involved in this process remain unclear, and further research is warranted. © 2017 John Wiley & Sons Ltd.
Johnston, William; Dolan, Kara; Reid, Niamh; Coughlan, Garrett F; Caulfield, Brian
2018-01-01
The Y Balance Test is one of the most commonly used dynamic balance assessments, providing an insight into the integration of the sensorimotor subsystems. In recent times, there has been an increase in interest surrounding it's use in various clinical populations demonstrating alterations in motor function. Therefore, it is important to examine the effect physiological influences such as fatigue play in dynamic postural control, and establish a timeframe for its recovery. Descriptive laboratory study. Twenty male and female (age 23.75±4.79years, height 174.12±8.45cm, mass 69.32±8.76kg) partaking in competitive sport, completed the Y Balance Test protocol at 0, 10 and 20min, prior to a modified 60s Wingate fatiguing protocol. Post-fatigue assessments were then completed at 0, 10 and 20 min post-fatiguing intervention. Intraclass correlation coefficients demonstrated excellent intra-session reliability (0.976-0.982) across the three pre-fatigue YBT tests. Post-hoc paired sample t-tests demonstrated that all three reach directions demonstrated statistically significant differences between pre-fatigue and the first post-fatigue measurement (anterior; p=0.019, posteromedial; p=0.019 & posterolateral; p=0.003). The anterior reach direction returned to pre-fatigue levels within 10min (p=0.632). The posteromedial reach direction returned to pre-fatigue levels within 20min (p=0.236), while the posterolateral direction maintained a statistically significant difference at 20min (p=0.023). Maximal anaerobic fatigue has a negative effect on normalised Y balance test scores in all three directions. Following the fatiguing protocol, dynamic postural control returns to pre-fatigue levels for the anterior (<10min), posteromedial (<20min) and posterolateral (>20min). Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Lee, Young-Mee; Sohng, Kyeong-Yae
2005-12-01
The purpose of this study was to determine the effects of foot reflexology on fatigue and insomnia in patients suffering from coal workers' pneumoconiosis. This study was a quasi-experimental study of pre-test and post-test design in a non-equivalent control group. The subjects of this study consisted of both the experimental group of twenty-nine and the control group of thirty coal workers' pneumoconiosis patients. Data was collected from December 10, 2002 to February 15, 2003. Foot reflexology was performed for 60 minutes twice a week through five weeks in the experimental group, but none in the control group. To evaluate the effects of foot reflexology, the scores of fatigue and insomnia were measured before and after the experiment in both groups. Fatigue was evaluated by Fatigue Symptoms Inventory. Insomnia was measured with the visual analogue scale (VAS). Data of this experiment was analyzed by Chi-square test, t-test, unpaired t-test and Repeated Measures ANOVA with the SAS Program. The scores of fatigue and insomnia decreased in the experimental group but not in the control group. There was a significant difference of fatigue and insomnia between the two groups. It is suggested that foot reflexology might have beneficial effects on reducing fatigue and insomnia in patients suffering from coal workers' pneumoconiosis, and can be recommended as a nursing intervention program for patients with coal workers' pneumoconiosis.
Review of specimen heating in mechanical tests at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Ogata, T.; Yuri, T.; Ono, Y.
2014-01-01
At cryogenic temperatures near 4 K, a discontinuous deformation produces a large amount of specimen temperature rise that might bring significant changes in mechanical properties. The authors measured the specimen heating in tensile tests, fatigue test, and other tests in liquid helium for stainless steels and other materials. In this paper, we have measured the specimen temperature in high-cycle and low-cycle fatigue tests for stainless steels at various frequencies and stress levels and evaluated the testing conditions to keep the specimen at a specified temperature. We proposed maximum frequency in load-controlled fatigue tests for specified loading variables and a maximum strain rate in strain-controlled fatigue tests.
Effects of Control Mode and R-Ratio on the Fatigue Behavior of a Metal Matrix Composite
NASA Technical Reports Server (NTRS)
2005-01-01
Composite Because of their high specific stiffness and strength at elevated temperatures, continuously reinforced metal matrix composites (MMC's) are under consideration for a future generation of aeropropulsion systems. Since components in aeropropulsion systems experience substantial cyclic thermal and mechanical loads, the fatigue behavior of MMC's is of great interest. Almost without exception, previous investigations of the fatigue behavior of MMC's have been conducted in a tension-tension, load-controlled mode. This has been due to the fact that available material is typically less than 2.5-mm thick and, therefore, unable to withstand high compressive loads without buckling. Since one possible use of MMC's is in aircraft skins, this type of testing mode may be appropriate. However, unlike aircraft skins, most engine components are thick. In addition, the transient thermal gradients experienced in an aircraft engine will impose tension-compression loading on engine components, requiring designers to understand how the MMC will behave under fully reversed loading conditions. The increased thickness of the MMC may also affect the fatigue life. Traditionally, low-cycle fatigue (LCF) tests on MMC's have been performed in load control. For monolithic alloys, low-cycle fatigue tests are more typically performed in strain control. Two reasons justify this choice: (1) the critical volume from which cracks initiate and grow is generally small and elastically constrained by the larger surrounding volume of material, and (2) load-controlled, low-cycle fatigue tests of monolithics invariably lead to unconstrained ratcheting and localized necking--an undesired material response because the failure mechanism is far more severe than, and unrelated to, the fatigue mechanism being studied. It is unknown if this is the proper approach to composite testing. However, there is a lack of strain-controlled data on which to base any decisions. Consequently, this study addresses the isothermal, LCF behavior of a [0]_32 MMC tested under strain- and load-controlled conditions for both zero-tension and tension-compression loading conditions. These tests were run at 427 C on thick specimens of SiC-reinforced Ti-15-3. For the fully-reversed tests, no difference was observed in the lives between the load- and strain-controlled tests. However, for the zero-tension tests, the strain-controlled tests had longer lives by a factor of 3 in comparison to the load-controlled tests. This was due to the fact that under strain-control the specimens cyclically softened, reducing the cracking potential. In contrast, the load-controlled tests ratcheted toward larger tensile strains leading to an eventual overload of the fibers. Fatigue tests revealed that specimens tested under fully-reversed conditions had lives approximately an order of magnitude longer than for those specimens tested under zero tension. When examined on a strain-range basis, the fully reversed specimens had similar, but still shorter lives than those of the unreinforced matrix material. However, the composite had a strain limitation at short lives because of the limited strain capacity of the brittle ceramic fiber. The composite also suffered at very high lives because of the lack of an apparent fatigue limit in comparison to the unreinforced matrix. The value of adding fibers to the matrix is apparent when the fatigue lives are plotted as a function of stress range. Here, the composite is far superior to the unreinforced matrix because of the additional load-carrying capacity of the fibers.
2015-12-01
hardening heat treatment were the controlling factors of the fatigue resistance, while testing directions have the least impact. Leuders et al. [16...radius. The microstructurally-small fatigue crack growth test was run under load control at constant stress ratio R=0.1 and a cyclic frequency of 20 Hz...not been thoroughly investigated. In this study, long fatigue crack growth tests were conducted at two stress ratios (R=0.1 and 0.8), using Ti-6Al
Cognitive fatigue in patients with myasthenia gravis.
Jordan, Berit; Schweden, Tabea L K; Mehl, Theresa; Menge, Uwe; Zierz, Stephan
2017-09-01
Cognitive fatigue has frequently been reported in myasthenia gravis (MG). However, objective assessment of cognitive fatigability has never been evaluated. Thirty-three MG patients with stable generalized disease and 17 healthy controls underwent a test battery including repeated testing of attention and concentration (d2-R) and Paced Auditory Serial Addition Test. Fatigability was based on calculation of linear trend (LT) reflecting dynamic performance within subsequent constant time intervals. Additionally, fatigue questionnaires were used. MG patients showed a negative LT in second d2-R testing, indicating cognitive fatigability. This finding significantly differed from stable cognitive performance in controls (P < 0.05). Results of Paced Auditory Serial Addition Test testing did not differ between groups. Self-assessed fatigue was significantly higher in MG patients compared with controls (P < 0.001), but did not correlate with LT. LT quantifies cognitive fatigability as an objective measurement of performance decline in MG patients. Self-assessed cognitive fatigue is not correlated with objective findings. Muscle Nerve 56: 449-457, 2017. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Scholz, R.; Mueller, R.
1998-10-01
Strain controlled fatigue tests have been performed in torsion at 400°C on type 316L stainless steel samples in both 20% cold worked and annealed conditions during an irradiation with 19 MeV deuterons. A hold-time was imposed in the loading cycle. For the cold worked (cw) material, at shear strain ranges of 1.13% and 1.3%, irradiation creep induced stress relaxation led to the built up of a mean stress. The fatigue life was significantly reduced in comparison to thermal control tests. For the annealed (ann) material, tested under similar experimental conditions, irradiation creep effects were negligibly small compared to cyclic and irradiation hardening. The fatigue life was only slightly reduced. Continuous cycling tests conducted under irradiation conditions lay in the scatter band of the thermal control tests. The difference in fatigue life between continuous cycling and hold-time tests is attributed mainly to the observed difference in irradiation hardening.
Steib, Simon; Hentschke, Christian; Welsch, Goetz; Pfeifer, Klaus; Zech, Astrid
2013-08-01
Sensorimotor control is permanently impaired following functional ankle instability and temporarily decreased following fatigue. Little is known on potential interactions between both conditions. The purpose was to investigate the effect of fatiguing exercise on sensorimotor control in athletes with and without (coper, controls) functional ankle instability. 19 individuals with functional ankle instability, 19 ankle sprain copers, and 19 non-injured controls participated in this cohort study. Maximum reach distance in the star excursion balance test, unilateral jump landing stabilization time, center of pressure sway velocity in single-leg-stance, and passive ankle joint position sense were assessed before and immediately after fatiguing treadmill running. A three factorial linear mixed model was specified for each outcome to evaluate the effects of group, exhausting exercise (fatigue) and their interactions (group by fatigue). Effect sizes were calculated as Cohen's d. Maximum reach distance in the star excursion balance test, jump stabilization time and sway velocity, but not joint position sense, were negatively affected by fatigue in all groups. Effect sizes were moderate, ranging from 0.27 to 0.68. No significant group by fatigue interactions were found except for one measure. Copers showed significantly larger prefatigue to postfatigue reductions in anterior reach direction (P≤0.001; d=-0.55) compared to the ankle instability (P=0.007) and control group (P=0.052). Fatiguing exercise negatively affected postural control but not proprioception. Ankle status did not appear to have an effect on fatigue-induced sensorimotor control impairments. © 2013.
NASA Technical Reports Server (NTRS)
Gabb, T. P.; Gayda, J.; Lerch, B. A.; Halford, G. R.
1991-01-01
The relationship between constituent and MMC properties in fatigue loading is investigated with low-cycle fatigue-resistance testing of an alloy Ti-15-3 matrix reinforced with SiC SCS-6 fibers. The fabrication of the composite is described, and specimens are generated that are weak and ductile (WD), strong and moderately ductile (SM), or strong and brittle (SB). Strain is measured during MMC fatigue tests at a constant load amplitude with a load-controlled waveform and during matrix-alloy fatigue tests at a constant strain amplitude using a strain-controlled waveform. The fatigue resistance of the (0)8 SiC/Ti-15-3 composite is found to be slightly influenced by matrix mechanical properties, and the composite- and matrix-alloy fatigue lives are not correlated. This finding is suggested to relate to the different crack-initiation and -growth processes in MMCs and matrix alloys.
An Axial-Torsional, Thermomechanical Fatigue Testing Technique
NASA Technical Reports Server (NTRS)
Kalluri, Sreeramesh; Bonacuse, Peter J.
1995-01-01
A technique for conducting strain-controlled, thermomechanical, axial-torsional fatigue tests on thin-walled tubular specimens was developed. Three waveforms of loading, namely, the axial strain waveform, the engineering shear strain waveform, and the temperature waveform were required in these tests. The phasing relationships between the mechanical strain waveforms and the temperature and axial strain waveforms were used to define a set of four axial-torsional, thermomechanical fatigue (AT-TMF) tests. Real-time test control (3 channels) and data acquisition (a minimum of 7 channels) were performed with a software program written in C language and executed on a personal computer. The AT-TMF testing technique was used to investigate the axial-torsional thermomechanical fatigue behavior of a cobalt-base superalloy, Haynes 188. The maximum and minimum temperatures selected for the AT-TMF tests were 760 and 316 C, respectively. Details of the testing system, calibration of the dynamic temperature profile of the thin-walled tubular specimen, thermal strain compensation technique, and test control and data acquisition schemes, are reported. The isothermal, axial, torsional, and in- and out-of-phase axial-torsional fatigue behaviors of Haynes 188 at 316 and 760 C were characterized in previous investigations. The cyclic deformation and fatigue behaviors of Haynes 188 in AT-TMF tests are compared to the previously reported isothermal axial-torsional behavior of this superalloy at the maximum and minimum temperatures.
Fatigue acceptance test limit criterion for larger diameter rolled thread fasteners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kephart, A.R.
1997-05-01
This document describes a fatigue lifetime acceptance test criterion by which studs having rolled threads, larger than 1.0 inches in diameter, can be assured to meet minimum quality attributes associated with a controlled rolling process. This criterion is derived from a stress dependent, room temperature air fatigue database for test studs having a 0.625 inch diameter threads of Alloys X-750 HTH and direct aged 625. Anticipated fatigue lives of larger threads are based on thread root elastic stress concentration factors which increase with increasing thread diameters. Over the thread size range of interest, a 30% increase in notch stress ismore » equivalent to a factor of five (5X) reduction in fatigue life. The resulting diameter dependent fatigue acceptance criterion is normalized to the aerospace rolled thread acceptance standards for a 1.0 inch diameter, 0.125 inch pitch, Unified National thread with a controlled Root radius (UNR). Testing was conducted at a stress of 50% of the minimum specified material ultimate strength, 80 Ksi, and at a stress ratio (R) of 0.10. Limited test data for fastener diameters of 1.00 to 2.25 inches are compared to the acceptance criterion. Sensitivity of fatigue life of threads to test nut geometry variables was also shown to be dependent on notch stress conditions. Bearing surface concavity of the compression nuts and thread flank contact mismatch conditions can significantly affect the fastener fatigue life. Without improved controls these conditions could potentially provide misleading acceptance data. Alternate test nut geometry features are described and implemented in the rolled thread stud specification, MIL-DTL-24789(SH), to mitigate the potential effects on fatigue acceptance data.« less
Fatigue of immature baboon cortical bone.
Keller, T S; Lovin, J D; Spengler, D M; Carter, D R
1985-01-01
Strain-controlled uniaxial fatigue and monotonic tensile tests were conducted on turned femoral cortical bone specimens obtained from baboons at various ages of maturity. Fatigue loading produced a progressive loss in stiffness and an increase in hysteresis prior to failure, indicating that immature primate cortical bone responds to repeated loading in a fashion similar to that previously observed for adult human cortical bone. Bone fatigue resistance under this strain controlled testing decreased during maturation. Maturation was also associated with an increase in bone dry density, ash fraction and elastic modulus. The higher elastic modulus of more mature bone meant that these specimens were subjected to higher stress levels during testing than more immature bone specimens. Anatomical regions along the femoral shaft exhibited differences in strength and fatigue resistance.
Boggero, Ian A; Rojas-Ramirez, Marcia V; Carlson, Charles R
2017-03-01
Fatigue is known to be a pathway through which depression, psychological distress, pain intensity, and sleep disturbance influence pain interference, but the independent effects of fatigue on pain interference after controlling for these variables remains unknown. In addition, no study to date has tested whether fatigue subtypes of general fatigue, mental fatigue, emotional fatigue, physical fatigue, or vigor differentially predict pain interference. The current study tested these associations using archival medical data of 2133 chronic orofacial pain patients, who completed a battery of psychological questionnaires at the time of their first appointment at an orofacial pain clinic. Hierarchical linear regression analysis revealed that after controlling for depression, psychological distress, sleep disturbance, pain intensity, and demographic variables, fatigue predicted higher pain interference (B=0.70, SE=0.17, P<0.001, η=0.01). Physical fatigue (B=1.70, SE=0.48, P<0.001, η=0.01) and vigor (B=-3.24, SE=0.47, P<0.001, η=0.03) were independently associated with pain interference after controlling for the aforementioned variables. The findings suggest that fatigue is an important independent predictor of pain interference and not merely a mediator. These findings also suggest that not all fatigue is created equal. Interventions aimed at reducing pain interference should target specific fatigue symptoms of physical fatigue and vigor. Future research investigating the independent associations of fatigue subtypes on pain outcomes may help clarify the nature of the interrelationships between pain and fatigue.
Rolling-Element Fatigue Testing and Data Analysis - A Tutorial
NASA Technical Reports Server (NTRS)
Vlcek, Brian L.; Zaretsky, Erwin V.
2011-01-01
In order to rank bearing materials, lubricants and other design variables using rolling-element bench type fatigue testing of bearing components and full-scale rolling-element bearing tests, the investigator needs to be cognizant of the variables that affect rolling-element fatigue life and be able to maintain and control them within an acceptable experimental tolerance. Once these variables are controlled, the number of tests and the test conditions must be specified to assure reasonable statistical certainty of the final results. There is a reasonable correlation between the results from elemental test rigs with those results obtained with full-scale bearings. Using the statistical methods of W. Weibull and L. Johnson, the minimum number of tests required can be determined. This paper brings together and discusses the technical aspects of rolling-element fatigue testing and data analysis as well as making recommendations to assure quality and reliable testing of rolling-element specimens and full-scale rolling-element bearings.
Reduced Electromyographic Fatigue Threshold after Performing a Cognitive Fatiguing Task.
Ferris, Justine R; Tomlinson, Mary A; Ward, Tayler N; Pepin, Marie E; Malek, Moh H
2018-02-22
Cognitive fatigue tasks performed prior to exercise may reduce exercise capacity. The electromyographic fatigue threshold (EMGFT) is the highest exercise intensity that can be maintained without significant increase in the EMG amplitude versus time relationship. To date, no studies have examined the effect of cognitive fatigue on the estimation of the EMGFT. The purpose of this study, therefore, was to determine whether or not cognitive fatigue prior to performing exercise reduces the estimated EMGFT. Eight healthy college-aged men were recruited from a university student population and visited the laboratory on multiple occasions. In a randomized order, subjects performed either the cognitive fatigue task (AX Continuous Performance Test; AX-CPT) for 60 min on one visit (experimental condition) or watched a video on trains for 60 min on the other visit (control condition). After each condition, subjects performed the incremental single-leg knee-extensor ergometry test while the EMG amplitude was recorded from the rectus femoris muscle and heart rate was monitored throughout. Thereafter, the EMGFT was calculated for each participant for each visit and compared using paired samples t-test. For exercise outcomes, there were no significant mean differences for maximal power output between the two conditions (control: 51 ± 5 vs. fatigue: 50 ± 3 W), but a significant decrease in EMGFT between the two conditions (control: 31 ± 3 vs. fatigue: 24 ± 2 W; p = 0.013). Moreover, maximal heart rate was significantly different between the two conditions (control: 151 ± 5 vs. fatigue: 132 ± 6; p = 0.027). These results suggest that performing the cognitive fatiguing task reduces the EMGFT with a corresponding reduction in maximal heart rate response.
Failure and fatigue characteristics of adhesive athletic tape.
Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P
2002-03-01
Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.
Evaluation of materials during outdoor testing using a computer-controlled test apparatus
R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White
2006-01-01
Ultraviolet radiation, moisture, heat, and cyclic fatigue are some of the stressors that cause materials to degrade outdoors. Considerable research has addressed the effects of ultraviolet radiation and moisture on the rate of this degradation. An often overlooked stressor on materials, during outdoor testing, is the cyclic fatigue. Cyclic fatigue is caused by self-...
Assessment of physical fatigability and fatigue perception in myasthenia gravis.
Jordan, Berit; Mehl, Theresa; Schweden, Tabea L K; Menge, Uwe; Zierz, Stephan
2017-05-01
Fatigue includes both performance fatigability and fatigue perception. In 32 stable patients with generalized myasthenia gravis (MG) and 17 controls, time-dependent physical performance was assessed by the arm movement test (AMT) and 6-minute walk test (6MWT). MG patients presented with low quantitative MG scores (mean 0.5, SD 0.5) and without pathologic decrement. Fatigability was based on calculation of linear trend (LT) reflecting dynamic performance within subsequent constant time intervals. Perception of physical fatigue was analyzed using fatigue questionnaires. MG patients showed a negative LT in both AMT and 6MWT, significantly differing from stable performance in controls. LT inversely correlated with elevation of acetylcholine receptor antibodies (r = -0.59, P < 0.005) but not with quantitative MG score and fatigue perception. LT allows quantification of fatigability as an objective measurement of decline in individual performance, even in patients without obvious neuromuscular deficits in routine testing. The missing correlation of experienced fatigue supports the multidimensional fatigue model. Muscle Nerve 55: 657-663, 2017. © 2016 Wiley Periodicals, Inc.
Low cycle fatigue and creep-fatigue behavior of Ni-based alloy 230 at 850 C
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiang; Yang, Zhiqing; Sokolov, Mikhail A
Strain-controlled low cycle fatigue (LCF) and creep-fatigue testing of Ni-based alloy 230 were carried out at 850 C. The material creep-fatigue life decreased compared with its low cycle fatigue life at the same total strain range. Longer hold time at peak tensile strain further reduced the material creep-fatigue life. Based on the electron backscatter diffraction, a novel material deformation characterization method was applied, which revealed that in low cycle fatigue testing as the total strain range increased, the deformation was segregated to grain boundaries since the test temperature was higher than the material equicohesive temperature and grain boundaries became weakermore » regions compared with grains. Creep-fatigue tests enhanced the localized deformation, resulting in material interior intergranular cracking, and accelerated material damage. Precipitation in alloy 230 helped slip dispersion, favorable for fatigue property, but grain boundary cellular precipitates formed after material exposure to the elevated temperature had a deleterious effect on the material low cycle fatigue and creep-fatigue property.« less
Creep-Fatigue Damage Investigation and Modeling of Alloy 617 at High Temperatures
NASA Astrophysics Data System (ADS)
Tahir, Fraaz
The Very High Temperature Reactor (VHTR) is one of six conceptual designs proposed for Generation IV nuclear reactors. Alloy 617, a solid solution strengthened Ni-base superalloy, is currently the primary candidate material for the tubing of the Intermediate Heat Exchanger (IHX) in the VHTR design. Steady-state operation of the nuclear power plant at elevated temperatures leads to creep deformation, whereas loading transients including startup and shutdown generate fatigue. A detailed understanding of the creep-fatigue interaction in Alloy 617 is necessary before it can be considered as a material for nuclear construction in ASME Boiler and Pressure Vessel Code. Current design codes for components undergoing creep-fatigue interaction at elevated temperatures require creep-fatigue testing data covering the entire range from fatigue-dominant to creep-dominant loading. Classical strain-controlled tests, which produce stress relaxation during the hold period, show a saturation in cycle life with increasing hold periods due to the rapid stress-relaxation of Alloy 617 at high temperatures. Therefore, applying longer hold time in these tests cannot generate creep-dominated failure. In this study, uniaxial isothermal creep-fatigue tests with non-traditional loading waveforms were designed and performed at 850 and 950°C, with an objective of generating test data in the creep-dominant regime. The new loading waveforms are hybrid strain-controlled and force-controlled testing which avoid stress relaxation during the creep hold. The experimental data showed varying proportions of creep and fatigue damage, and provided evidence for the inadequacy of the widely-used time fraction rule for estimating creep damage under creep-fatigue conditions. Micro-scale damage features in failed test specimens, such as fatigue cracks and creep voids, were quantified using a Scanning Electron Microscope (SEM) to find a correlation between creep and fatigue damage. Quantitative statistical imaging analysis showed that the microstructural damage features (cracks and voids) are correlated with a new mechanical driving force parameter. The results from this image-based damage analysis were used to develop a phenomenological life-prediction methodology called the effective time fraction approach. Finally, the constitutive creep-fatigue response of the material at 950°C was modeled using a unified viscoplastic model coupled with a damage accumulation model. The simulation results were used to validate an energy-based constitutive life-prediction model, as a mechanistic model for potential component and structure level creep-fatigue analysis.
Experimental and modeling results of creep fatigue life of Inconel 617 and Haynes 230 at 850 C
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiang; Sokolov, Mikhail A; Sham, Sam
Creep fatigue testing of Ni-based superalloy Inconel 617 and Haynes 230 were conducted in the air at 850 C. Tests were performed with fully reversed axial strain control at a total strain range of 0.5%, 1.0% or 1.5% and hold time at maximum tensile strain for 3, 10 or 30 min. In addition, two creep fatigue life prediction methods, i.e. linear damage summation and frequency-modified tensile hysteresis energy modeling, were evaluated and compared with experimental results. Under all creep fatigue tests, Haynes 230 performed better than Inconel 617. Compared to the low cycle fatigue life, the cycles to failure formore » both materials decreased under creep fatigue test conditions. Longer hold time at maximum tensile strain would cause a further reduction in both material creep fatigue life. The linear damage summation could predict the creep fatigue life of Inconel 617 for limited test conditions, but considerably underestimated the creep fatigue life of Haynes 230. In contrast, frequency-modified tensile hysteresis energy modeling showed promising creep fatigue life prediction results for both materials.« less
Experimental and modeling results of creep-fatigue life of Inconel 617 and Haynes 230 at 850 °C
NASA Astrophysics Data System (ADS)
Chen, Xiang; Sokolov, Mikhail A.; Sham, Sam; Erdman, Donald L., III; Busby, Jeremy T.; Mo, Kun; Stubbins, James F.
2013-01-01
Creep-fatigue testing of Ni-based superalloy Inconel 617 and Haynes 230 were conducted in the air at 850 °C. Tests were performed with fully reversed axial strain control at a total strain range of 0.5%, 1.0% or 1.5% and hold time at maximum tensile strain for 3, 10 or 30 min. In addition, two creep-fatigue life prediction methods, i.e. linear damage summation and frequency-modified tensile hysteresis energy modeling, were evaluated and compared with experimental results. Under all creep-fatigue tests, Haynes 230 performed better than Inconel 617. Compared to the low cycle fatigue life, the cycles to failure for both materials decreased under creep-fatigue test conditions. Longer hold time at maximum tensile strain would cause a further reduction in both material creep-fatigue life. The linear damage summation could predict the creep-fatigue life of Inconel 617 for limited test conditions, but considerably underestimated the creep-fatigue life of Haynes 230. In contrast, frequency-modified tensile hysteresis energy modeling showed promising creep-fatigue life prediction results for both materials.
Effect of acute fatigue of the hip abductors on control of balance in young and older women.
Bellew, James W; Panwitz, Beth L; Peterson, Laura; Brock, Mary C; Olson, Katie E; Staples, William H
2009-07-01
To examine the effects of acute fatigue of the hip abductors on the control of balance in young and older women. Pretest-posttest. University research laboratory. Healthy young women (n=20; age, 23.0+/-1.5y; height, 166.52+/-4.5 cm; mass, 65.33+/-10.5 kg) and community-dwelling older women (n=20; age, 71.65+/-7.2y; height, 162.31+/-3.8 cm; mass, 71.16+/-11.6 kg) without a fall history. Measurements of control of single-limb balance before and after fatiguing the hip abductors of the dominant leg. Performance on 3 clinical assessments of control of balance: the modified Functional Reach Test in the forward, left, and right directions; the Lower-Extremity Reach Test in forward and lateral directions; and the Single-Limb Stance Time Test (SLSTT). Although the younger subjects showed a significantly greater control of balance than the older women in most tests, control of balance after acute fatigue failed to show a significant decline in either age group. The only exception to this was the SLSTT in the younger women in whom a significant 26% decline was noted (P<.05). Acute fatigue of the hip abductors did not result in a decreased control of balance in healthy young or older women without fall history. Despite considerable changes in movement strategies used to complete the postfatigue tests of balance, quantitative measures of balance did not decrease.
Low cycle fatigue behavior of polycrystalline NiAl at 300 and 1000 K
NASA Technical Reports Server (NTRS)
Lerch, Bradley A.; Noebe, Ronald D.
1993-01-01
The low cycle fatigue behavior of polycrystalline NiAl was determined at 300 and 1000 K - temperatures below and above the brittle- to-ductile transition temperature (BDTT). Fully reversed, plastic strain-controlled fatigue tests were conducted on two differently fabricated alloy samples: hot isostatically pressed (HIP'ed) prealloyed powder and hot extruded castings. HIP'ed powder (HP) samples were tested only at 1000 K, whereas the more ductile cast-and-extruded (C+E) NiAl samples were tested at both 1000 and 300 K. Plastic strain ranges of 0.06 to 0.2 percent were used. The C+E NiAl cyclically hardened until fracture, reaching stress levels approximately 60 percent greater than the ultimate tensile strength of the alloy. Compared on a strain basis, NiAl had a much longer fatigue life than other B2 ordered compounds in which fracture initiated at processing-related defects. These defects controlled fatigue life at 300 K, with fracture occurring rapidly once a critical stress level was reached. At 1000 K, above the BDTT, both the C+E and HP samples cyclically softened during most of the fatigue tests in air and were insensitive to processing defects. The processing method did not have a major effect on fatigue life; the lives of the HP samples were about a factor of three shorter than the C+E NiAl, but this was attributed to the lower stress response of the C+E material. The C+E NiAl underwent dynamic grain growth, whereas the HP material maintained a constant grain size during testing. In both materials, fatigue life was controlled by intergranular cavitation and creep processes, which led to fatigue crack growth that was primarily intergranular in nature. Final fracture by overload was transgranular in nature. Also, HP samples tested in vacuum had a life three times longer than their counterparts tested in air and, in contrast to those tested in air, hardened continuously over half of the sample life, thereby indicating an environmentally assisted fatigue damage mechanism. The C+E samples were tested only in air. At 1000 K, NiAl exhibited a superior fatigue life when compared to most superalloys on a plastic strain basis, but was inferior to most superalloys on a stress basis.
Moore, Halle C F; Parsons, Michael W; Yue, Guang H; Rybicki, Lisa A; Siemionow, Wlodzimierz
2014-08-01
Persistent fatigue and cognitive dysfunction are poorly understood potential long-term effects of adjuvant chemotherapy. In this pilot study, we assessed the value of electroencephalogram (EEG) power measurements as a means to evaluate physical and mental fatigue associated with chemotherapy. Women planning to undergo adjuvant chemotherapy for breast cancer and healthy controls underwent neurophysiologic assessments at baseline, during the time of chemotherapy treatment, and at 1 year. Repeated measures analysis of variance was used to analyze the data. Compared with controls, patients reported more subjective fatigue at baseline that increased during chemotherapy and did not entirely resolve by 1 year. Performance on endurance testing was similar in patients versus controls at all time points; however, values of EEG power increased after a physical task in patients during chemotherapy but not controls. Compared with controls, subjective mental fatigue was similar for patients at baseline and 1 year but worsened during chemotherapy. Patients performed similarly to controls on formal cognitive testing at all time points, but EEG activity after the cognitive task was increased in patients only during chemotherapy. EEG power measurement has the potential to provide a sensitive neurophysiologic correlate of cancer treatment-related fatigue and cognitive dysfunction.
Orbital fatigue tester for use in Skylab experiment T032
NASA Technical Reports Server (NTRS)
Sandorff, P. E.
1973-01-01
A prototype fatigue test machine is described which is suitable for use by an astronaut in conducting constant amplitude materials fatigue tests aboard a Skylab or space shuttle vehicle. The machine is comparised of a mechanical tester, which would be passed through a small (7.6-inch square) airlock to be supported in the space environment on an extendible boom, and a control console, which would provide remote control from within the space vehicle.
[Development and Application of an Overcoming Compassion Fatigue Program for Emergency Nurses].
Kim, Yeong Ah; Park, Jeong Sook
2016-04-01
This study was conducted to develop a program to help emergency nurses overcome compassion fatigue, and to analyze the effects of the program. A nonequivalent control group pretest-posttest design was used. There were 14 participants in the experimental group and 18 subjects in the control group. The program was comprised of five, weekly 80-minute sessions including understanding and assessment of compassion fatigue, enhancing positive affect, balancing work-life, planning self care, training in relaxation techniques and cognitive restructuring, and getting social support. Research variables were ego-resiliency, compassion satisfaction and compassion fatigue of the ProQOL 5, and salivary cortisol. Data were analyzed using Chi-square test, independent t-test, and paired t-test. The first hypothesis, "There will be a difference in scores for ego resiliency between the experimental group and the control group". was not supported. The second hypothesis, "There will be a difference in scores for compassion satisfaction between the experimental group and the control group" was supported (t=2.15, p=.046). The third hypothesis, "There will be a difference in scores for compassion fatigue between the experimental group and the control group" was not supported. The first program for emergency nurses to overcome compassion fatigue in Korea was effective in increasing emergency nurses' compassion satisfaction and decreasing salivary cortisol level in the experimental group. Therefore, this program for overcoming compassion fatigue is useful to increase emergency nurses' compassion satisfaction. However replication studies of short-term intensive program reflecting emergency nurses' opinion are needed.
Prediction of Mean and Design Fatigue Lives of Self Compacting Concrete Beams in Flexure
NASA Astrophysics Data System (ADS)
Goel, S.; Singh, S. P.; Singh, P.; Kaushik, S. K.
2012-02-01
In this paper, result of an investigation conducted to study the flexural fatigue characteristics of self compacting concrete (SCC) beams in flexure are presented. An experimental programme was planned in which approximately 60 SCC beam specimens of size 100 × 100 × 500 mm were tested under flexural fatigue loading. Approximately 45 static flexural tests were also conducted to facilitate fatigue testing. The flexural fatigue and static flexural strength tests were conducted on a 100 kN servo-controlled actuator. The fatigue life data thus obtained have been used to establish the probability distributions of fatigue life of SCC using two-parameter Weibull distribution. The parameters of the Weibull distribution have been obtained by different methods of analysis. Using the distribution parameters, the mean and design fatigue lives of SCC have been estimated and compared with Normally vibrated concrete (NVC), the data for which have been taken from literature. It has been observed that SCC exhibits higher mean and design fatigue lives compared to NVC.
Implementation of a Biaxial Resonant Fatigue Test Method on a Large Wind Turbine Blade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snowberg, D.; Dana, S.; Hughes, S.
2014-09-01
A biaxial resonant test method was utilized to simultaneously fatigue test a wind turbine blade in the flap and edge (lead-lag) direction. Biaxial resonant blade fatigue testing is an accelerated life test method utilizing oscillating masses on the blade; each mass is independently oscillated at the respective flap and edge blade resonant frequency. The flap and edge resonant frequency were not controlled, nor were they constant for this demonstrated test method. This biaxial resonant test method presented surmountable challenges in test setup simulation, control and data processing. Biaxial resonant testing has the potential to complete test projects faster than single-axismore » testing. The load modulation during a biaxial resonant test may necessitate periodic load application above targets or higher applied test cycles.« less
Energy-based fatigue model for shape memory alloys including thermomechanical coupling
NASA Astrophysics Data System (ADS)
Zhang, Yahui; Zhu, Jihong; Moumni, Ziad; Van Herpen, Alain; Zhang, Weihong
2016-03-01
This paper is aimed at developing a low cycle fatigue criterion for pseudoelastic shape memory alloys to take into account thermomechanical coupling. To this end, fatigue tests are carried out at different loading rates under strain control at room temperature using NiTi wires. Temperature distribution on the specimen is measured using a high speed thermal camera. Specimens are tested to failure and fatigue lifetimes of specimens are measured. Test results show that the fatigue lifetime is greatly influenced by the loading rate: as the strain rate increases, the fatigue lifetime decreases. Furthermore, it is shown that the fatigue cracks initiate when the stored energy inside the material reaches a critical value. An energy-based fatigue criterion is thus proposed as a function of the irreversible hysteresis energy of the stabilized cycle and the loading rate. Fatigue life is calculated using the proposed model. The experimental and computational results compare well.
Gamma Radiation Sterilization Reduces the High-cycle Fatigue Life of Allograft Bone.
Islam, Anowarul; Chapin, Katherine; Moore, Emily; Ford, Joel; Rimnac, Clare; Akkus, Ozan
2016-03-01
Sterilization by gamma radiation impairs the mechanical properties of bone allografts. Previous work related to radiation-induced embrittlement of bone tissue has been limited mostly to monotonic testing which does not necessarily predict the high-cycle fatigue life of allografts in vivo. We designed a custom rotating-bending fatigue device to answer the following questions: (1) Does gamma radiation sterilization affect the high-cycle fatigue behavior of cortical bone; and (2) how does the fatigue life change with cyclic stress level? The high-cycle fatigue behavior of human cortical bone specimens was examined at stress levels related to physiologic levels using a custom-designed rotating-bending fatigue device. Test specimens were distributed among two treatment groups (n = 6/group); control and irradiated. Samples were tested until failure at stress levels of 25, 35, and 45 MPa. At 25 MPa, 83% of control samples survived 30 million cycles (run-out) whereas 83% of irradiated samples survived only 0.5 million cycles. At 35 MPa, irradiated samples showed an approximately 19-fold reduction in fatigue life compared with control samples (12.2 × 10(6) ± 12.3 × 10(6) versus 6.38 × 10(5) ± 6.81 × 10(5); p = 0.046), and in the case of 45 MPa, this reduction was approximately 17.5-fold (7.31 × 10(5) ± 6.39 × 10(5) versus 4.17 × 10(4) ± 1.91 × 10(4); p = 0.025). Equations to estimate high-cycle fatigue life of irradiated and control cortical bone allograft at a certain stress level were derived. Gamma radiation sterilization severely impairs the high cycle fatigue life of structural allograft bone tissues, more so than the decline that has been reported for monotonic mechanical properties. Therefore, clinicians need to be conservative in the expectation of the fatigue life of structural allograft bone tissues. Methods to preserve the fatigue strength of nonirradiated allograft bone tissue are needed. As opposed to what monotonic tests might suggest, the cyclic fatigue life of radiation-sterilized structural allografts is likely severely compromised relative to the nonirradiated condition and therefore should be taken into consideration. Methods to reduce the effect of irradiation or to recover structural allograft bone tissue fatigue strength are important to pursue.
Muz, Gamze; Taşcı, Sultan
2017-10-01
The most common problems in hemodialysis patients are sleep disorders and fatigue. This randomized-controlled experimental study was conducted to determine the effect of aromatherapy applied by inhalation on sleep quality and fatigue level in hemodialysis patients. The study was completed in five hemodialysis centers settled in two provinces with 27 intervention group patients and 35 controls, being totally 62 patients, recruited with simple randomization. Ethical approval, informed consent from the individuals and institutional permission were obtained. Data were collected with a questionnaire form and Visual Analogue Scale (VAS) for fatigue, Piper fatigue scale, Pittsburgh Sleep Quality Index (PSQI), and follow-up forms for the patient and the researcher. Aromatherapy inhalation (sweet orange and lavender oil) was performed before going to bed every day for one month to the intervention group patients. No other application has been made to the control group patients except for standard hemodialysis treatment. All of the forms were performed at baseline and at follow-up at the end of the four weeks (baseline and last follow-up), VAS and Piper fatigue scale were performed during follow-ups at the end of every week (the first, second and third follow-ups). Data were statistically analyzed with Independent Samples t-test, one way analysis of variance, Pearson correlation analysis, chi-square test, Friedman and Mann Whitney U tests and Bonferroni test. p<0.05 was set as statistically significant in comparisons. Mean total and sub-dimension scores of VAS, Piper fatigue scale and PSQI (except for daytime sleepiness dysfunction sub-dimension) of the intervention and control groups at baseline were not significantly different (p>0.05). It was found that mean total and sub-dimension scores of VAS, Piper fatigue scale and PSQI of the intervention group significantly decreased in other follow-ups compared to the control group (p<0.05). Consequently, it was determined that aromatherapy applied by inhalation improved sleep quality, decreased fatigue level and severity in hemodialysis patients. Accordingly, aromatherapy prepared with sweet orange and lavender oil may be recommended to increase sleep quality and to decrease fatigue level of the hemodialysis patients. Copyright © 2017 Elsevier Inc. All rights reserved.
The influence of matrix microstructure
NASA Astrophysics Data System (ADS)
Vyletel, G. M.; Allison, J. E.; Aken, D. C.
1993-11-01
The low-cycle and high-cycle fatigue behavior and cyclic response of naturally aged and artificially aged 2219/TiC/15p and unreinforced 2219 Al were investigated utilizing plastic strain-controlled and stress-controlled testing. The cyclic response of both the reinforced and un-reinforced materials was similar for all plastic strain amplitudes tested except that the saturation stress level for the composite was always greater than that of the unreinforced material. The cyclic response of the naturally aged materials exhibited cyclic hardening and, in some cases, cyclic softening, while the cyclic response for the artificially aged materials showed no evidence of either cyclic hardening or softening. The higher ductility of the unreinforced material made it more resistant to fatigue failure at high strains, and thus, at a given plastic strain, it had longer fatigue life. It should be noted that the tensile ductilities of the 2219/TiC/15p were significantly higher than those previously reported for 2XXX-series composites. During stress-controlled test-ing at stresses below 220 MPa, the presence of TiC particles lead to an improvement in fatigue life. Above 220 MPa, no influence of TiC reinforcement on fatigue life could be detected. In both the composite and unreinforced materials, the low-cycle and high-cycle fatigue lives were found to be virtually independent of matrix microstructure.
Windsor, Phyllis M; Nicol, Kathleen F; Potter, Joan
2004-08-01
Advice to rest and take things easy if patients become fatigued during radiotherapy may be detrimental. Aerobic walking improves physical functioning and has been an intervention for chemotherapy-related fatigue. A prospective, randomized, controlled trial was performed to determine whether aerobic exercise would reduce the incidence of fatigue and prevent deterioration in physical functioning during radiotherapy for localized prostate carcinoma. Sixty-six men were randomized before they received radical radiotherapy for localized prostate carcinoma, with 33 men randomized to an exercise group and 33 men randomized to a control group. Outcome measures were fatigue and distance walked in a modified shuttle test before and after radiotherapy. There were no significant between group differences noted with regard to fatigue scores at baseline (P = 0.55) or after 4 weeks of radiotherapy (P = 0.18). Men in the control group had significant increases in fatigue scores from baseline to the end of radiotherapy (P = 0.013), with no significant increases observed in the exercise group (P = 0.203). A nonsignificant reduction (2.4%) in shuttle test distance at the end of radiotherapy was observed in the control group; however, in the exercise group, there was a significant increase (13.2%) in distance walked (P = 0.0003). Men who followed advice to rest and take things easy if they became fatigued demonstrated a slight deterioration in physical functioning and a significant increase in fatigue at the end of radiotherapy. Home-based, moderate-intensity walking produced a significant improvement in physical functioning with no significant increase in fatigue. Improved physical functioning may be necessary to combat radiation fatigue.
High temperature fatigue behavior of a SiC/Ti-24Al-11Nb composite
NASA Technical Reports Server (NTRS)
Bartolotta, P. A.; Brindley, P. K.
1990-01-01
A series of tension-tension strain- and load-controlled tests were conducted on unidirectional SiC/Ti-24Al-11Nb (at percent) composites at 425 and 815 C. Several regimes of damage were identified using Talrega's concept of fatigue life diagrams. Issues of test technique, test control mode, and definition of failure were also addressed.
NASA Astrophysics Data System (ADS)
Wu, Z. R.; Li, X.; Fang, L.; Song, Y. D.
2018-04-01
A new multiaxial fatigue life prediction model has been proposed in this paper. The concepts of nonlinear continuum damage mechanics and critical plane criteria were incorporated in the proposed model. The shear strain-based damage control parameter was chosen to account for multiaxial fatigue damage under constant amplitude loading. Fatigue tests were conducted on nickel-based superalloy GH4169 tubular specimens at the temperature of 400 °C under proportional and nonproportional loading. The proposed method was checked against the multiaxial fatigue test data of GH4169. Most of prediction results are within a factor of two scatter band of the test results.
Cognition, depression, fatigue, and quality of life in primary Sjögren's syndrome: correlations.
Koçer, Belgin; Tezcan, Mehmet Engin; Batur, Hale Zeynep; Haznedaroğlu, Şeminur; Göker, Berna; İrkeç, Ceyla; Çetinkaya, Rümeysa
2016-12-01
The aim of the present study was to investigate the prevalence and pattern of cognitive dysfunction observed in primary Sjögren's syndrome (PSS) and to examine the relationships between cognitive abilities, depression, fatigue, and quality of life. Thirty-two subjects with PSS were compared with 19 healthy controls on comprehensive neuropsychological, depression, fatigue, health state, and daily-life activities tests. There was low performance in Clock Drawing, COWAT, Paced Auditory Serial Addition Test (PASAT), Colorless Word Reading (Stroop1) and Recognizing Colors (Stroop2) Patterns of STROOP test, SDLT, Auditory-Verbal Learning Test (AVLT), immediate and long-term verbal memory, Benton Judgment of Line Orientation Test (BJLOT), and in all the patterns of RCFT in PSS patients compared to the healthy control group ( p < .05). It was observed an increased depression frequency and fatigue severity, impairment in health condition, and a decreased quality of life in PSS cases compared to the healthy controls ( p < .05). All the depression, fatigue severity, and quality of life tests showed a significant positive correlation with each other ( p < .05). A significant negative correlation between Clock Drawing and SF-36-BP ( p = .031, r = -.382) and SF-36-GH ( p = .027, r = -.392) was observed. Clock Drawing, PASAT, and AVLT are very useful tests to determine the subclinical and clinical cognitive dysfunction to evaluate attention, information processing speed, executive functions, and short-term and long-term verbal memory in PSS patients. Depression and fatigue may not affect the neuropsychological tests performance.
Cumulative Axial and Torsional Fatigue: An Investigation of Load-Type Sequencing Effects
NASA Technical Reports Server (NTRS)
Kalluri, Sreeramesh; Bonacuse, Peter J.
2000-01-01
Cumulative fatigue behavior of a wrought cobalt-base superalloy, Haynes 188 was investigated at 538 C under various single-step sequences of axial and torsional loading conditions. Initially, fully-reversed, axial and torsional fatigue tests were conducted under strain control at 538 C on thin-walled tubular specimens to establish baseline fatigue life relationships. Subsequently, four sequences (axial/axial, torsional/torsional, axial/torsional, and torsional/axial) of two load-level fatigue tests were conducted to characterize both the load-order (high/low) and load-type sequencing effects. For the two load-level tests, summations of life fractions and the remaining fatigue lives at the second load-level were computed by the Miner's Linear Damage Rule (LDR) and a nonlinear Damage Curve Approach (DCA). In general, for all four cases predictions by LDR were unconservative. Predictions by the DCA were within a factor of two of the experimentally observed fatigue lives for a majority of the cumulative axial and torsional fatigue tests.
Fatigue and durability of Nitinol stents.
Pelton, A R; Schroeder, V; Mitchell, M R; Gong, Xiao-Yan; Barney, M; Robertson, S W
2008-04-01
Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, the cyclic fatigue and durability properties of Nitinol-based endovascular stents are discussed in terms of an engineering-based experimental testing program. In this paper, the combined effects of cardiac pulsatile fatigue and stent-vessel oversizing are evaluated for application to both stents and stent subcomponents. In particular, displacement-controlled fatigue tests were performed on stent-like specimens processed from Nitinol microtubing. Fatigue data were collected with combinations of simulated oversizing conditions and pulsatile cycles that were identified by computer modeling of the stent that mimic in vivo deformation conditions. These data are analyzed with non-linear finite element computations and are illustrated with strain-life and strain-based constant-life diagrams. The utility of this approach is demonstrated in conjunction with 10 million cycle pulsatile fatigue tests of Cordis SMART Control((R)) Nitinol self-expanding stents to calculate fatigue safety factors and thereby predict in vivo fatigue resistance. These results demonstrate the non-linear constant fatigue-life response of Nitinol stents, whereby, contrary to conventional engineering materials, the fatigue life of Nitinol is observed to increase with increasing mean strain.
Fatigue-environment interactions in a SiC/Ti-15-3 composite
NASA Technical Reports Server (NTRS)
Gayda, J.; Gabb, T. P.; Lerch, B. A.
1993-01-01
Load-controlled isothermal and nonisothermal fatigue lives of a (0-deg)s SiC/Ti-15-3 were evaluated at temperatures between 150 and 550 C and a target strain range of about 0.45 percent. In nonisothermal fatigue tests, load was first cycled at minimum temperature and then temperature was cycled at zero load. For fatigue tests with peak temperatures at or above 300 C, fatigue life was dramatically reduced compared to that at 150 C. The shortest life was produced by the nonisothermal test with the greatest temperature range (Delta T = 400 C) and highest peak temperature (T(max) = 550 C). Vacuum testing showed that much of the life reduction under isothermal and nonisothermal conditions was related to environmental effects, although the nature of the fatigue-environment interaction was decidedly different for the isothermal and nonisothermal test cycles which were studied.
Evidence for sensitized fatigue pathways in patients with chronic fatigue syndrome.
Staud, Roland; Mokthech, Meriem; Price, Donald D; Robinson, Michael E
2015-04-01
Patients with chronic fatigue syndrome (CFS) frequently demonstrate intolerance to physical exertion that is often reported as increased and long-lasting fatigue. Because no specific metabolic alterations have been identified in CFS patients, we hypothesized that sensitized fatigue pathways become activated during exercise corresponding with increased fatigue. After exhausting handgrip exercise, muscle metabolites were trapped in the forearm tissues of 39 CFS patients and 29 normal control (NC) by sudden occlusion for up to 5 minutes. A nonocclusive condition of similar duration was used as control. Repeated fatigue and pain ratings were obtained before and after exercise. Mechanical and heat hyperalgesia were assessed by quantitative sensory testing. All subjects fulfilled the 1994 Fukuda Criteria for CFS. Normal control and CFS subjects exercised for 6.6 (2.4) and 7.0 (2.7) minutes (P > 0.05). Forearm occlusion lasted for 4.7 (1.3) and 4.9 (1.8) minutes in NC and CFS subjects, respectively (P > 0.05). Although fatigue ratings of CFS subjects increased from 4.8 (2.0) to 5.6 (2.1) visual analogue scale (VAS) units during forearm occlusion, they decreased from 5.0 (1.8) to 4.8 (2.0) VAS units during the control condition without occlusion (P = 0.04). A similar time course of fatigue ratings was observed in NC (P > 0.05), although their ratings were significantly lower than those of CFS subjects (P < 0.001). Quantitative sensory testing demonstrated heat and mechanical hyperalgesia in CFS subjects. Our findings provide indirect evidence for significant contributions of peripheral tissues to the increased exercise-related fatigue in CFS patients consistent with sensitization of fatigue pathways. Future interventions that reduce sensitization of fatigue pathways in CFS patients may be of therapeutic benefit.
Is the Sørensen test valid to assess muscle fatigue of the trunk extensor muscles?
Demoulin, Christophe; Boyer, Mathieu; Duchateau, Jacques; Grosdent, Stéphanie; Jidovtseff, Boris; Crielaard, Jean-Michel; Vanderthommen, Marc
2016-01-01
Very few studies have quantified the degree of fatigue characterized by the decline in the maximal voluntary contraction (MVC) force of the trunk extensors induced by the widely used Sørensen test. Measure the degree of fatigue of the trunk extensor muscles induced by the Sørensen test. Eighty young healthy subjects were randomly divided into a control group (CG) and an experimental group (EG), each including 50% of the two genders. The EG performed an isometric MVC of the trunk extensors (pre-fatigue test) followed by the Sørensen test, the latter being immediately followed by another MVC (post-fatigue test). The CG performed only the pre- and post-fatigue tests without any exertion in between. The comparison of the pre- and post-fatigue tests revealed a significant (P< 0.05) decrease in MVC force normalized by body mass (-13%) in the EG, whereas a small increase occurred in the CG (+2.7%, P= 0.001). This study shows that the Sørensen test performed until failure in a young healthy population results in a reduced ability of the trunk extensor muscles to generate maximal force, and indicates that this test is valid for the assessment of fatigue in trunk extensor muscles.
Crack Initiation and Growth Behavior at Corrosion Pit in 7075-T6 Under Biaxial and Uniaxial Fatigue
2014-06-19
al. examined the effect of biaxial loading on the fatigue crack growth [52]. They conducted their fatigue tests on SUS 304 stainless steel using a...specimens. Their experiments were carried out on cruciform test coupons using a digitally controlled four actuator biaxial testing system. Steel ...as shown in Figure 3.7. The test specimen was placed between two stainless steel chambers. These chambers were connected together using screws, and
Creep-fatigue of low cobalt superalloys
NASA Technical Reports Server (NTRS)
Halford, G. R.
1982-01-01
Testing for the low cycle fatigue and creep fatigue resistance of superalloys containing reduced amounts of cobalt is described. The test matrix employed involves a single high temperature appropriate for each alloy. A single total strain range, again appropriate to each alloy, is used in conducting strain controlled, low cycle, creep fatigue tests. The total strain range is based upon the level of straining that results in about 10,000 cycles to failure in a high frequency (0.5 Hz) continuous strain-cycling fatigue test. No creep is expected to occur in such a test. To bracket the influence of creep on the cyclic strain resistance, strain hold time tests with ore minute hold periods are introduced. One test per composition is conducted with the hold period in tension only, one in compression only, and one in both tension and compression. The test temperatures, alloys, and their cobalt compositions that are under study are given.
Shirazi, Zahra Rojhani; Jahromi, Fatemeh Nikhalat
2013-09-01
The maintenance of balance is an essential requirement for the performance of daily tasks and sporting activities and muscular fatigue is a factor to impair postural control, so this study was done to compare the effect of selected muscle groups fatigue on postural control during bipedal stance in healthy subjects. Fifteen healthy female students (24.3 ± 2.6 years) completed three testing session with a break period of at least 2 days. During each session, postural control was assessed during two 30-s trials of bipedal stance with eyes close before and after the fatigue protocol. Fatigue protocols were performed by 60% of their unfatigued Maximum Voluntary Contraction of unilateral ankle plantar flexors, bilateral lumbar extensors and bilateral neck extensors. One of the three fatigue protocols was performed on each session. The result showed that fatigue had a significant effect on COP velocity and it increase COP velocity but there was not found any difference in postural sway between muscle groups. Localized muscle fatigue caused deficits in postural control regardless of the location of fatigue. Authors suggest the possibility of the contributions of central mechanisms to postural deficits due to fatigue and it seems that difference was not between muscle groups due to central fatigue.
Deformation history and load sequence effects on cumulative fatigue damage and life predictions
NASA Astrophysics Data System (ADS)
Colin, Julie
Fatigue loading seldom involves constant amplitude loading. This is especially true in the cooling systems of nuclear power plants, typically made of stainless steel, where thermal fluctuations and water turbulent flow create variable amplitude loads, with presence of mean stresses and overloads. These complex loading sequences lead to the formation of networks of microcracks (crazing) that can propagate. As stainless steel is a material with strong deformation history effects and phase transformation resulting from plastic straining, such load sequence and variable amplitude loading effects are significant to its fatigue behavior and life predictions. The goal of this study was to investigate the effects of cyclic deformation on fatigue behavior of stainless steel 304L as a deformation history sensitive material and determine how to quantify and accumulate fatigue damage to enable life predictions under variable amplitude loading conditions for such materials. A comprehensive experimental program including testing under fully-reversed, as well as mean stress and/or mean strain conditions, with initial or periodic overloads, along with step testing and random loading histories was conducted on two grades of stainless steel 304L, under both strain-controlled and load-controlled conditions. To facilitate comparisons with a material without deformation history effects, similar tests were also carried out on aluminum 7075-T6. Experimental results are discussed, including peculiarities observed with stainless steel behavior, such as a phenomenon, referred to as secondary hardening characterized by a continuous increase in the stress response in a strain-controlled test and often leading to runout fatigue life. Possible mechanisms for secondary hardening observed in some tests are also discussed. The behavior of aluminum is shown not to be affected by preloading, whereas the behavior of stainless steel is greatly influenced by prior loading. Mean stress relaxation in strain control and ratcheting in load control and their influence on fatigue life are discussed. Some unusual mean strain test results are presented for stainless steel 304L, where in spite of mean stress relaxation fatigue lives were significantly longer than fully-reversed tests. Prestraining indicated no effect on either deformation or fatigue behavior of aluminum, while it induced considerable hardening in stainless steel 304L and led to different results on fatigue life, depending on the test control mode. In step tests for stainless steel 304L, strong hardening induced by the first step of a high-low sequence significantly affects the fatigue behavior, depending on the test control mode used. For periodic overload tests of stainless steel 340L, hardening due to the overloads was progressive throughout life and more significant than in high-low step tests. For aluminum, no effect on deformation behavior was observed due to periodic overloads. However, the direction of the overloads was found to affect fatigue life, as tensile overloads led to longer lives, while compressive overloads led to shorter lives. Deformation and fatigue behaviors under random loading conditions are also presented and discussed for the two materials. The applicability of a common cumulative damage rule, the linear damage rule, is assessed for the two types of material, and for various loading conditions. While the linear damage rule associated with a strain-life or stress-life curve is shown to be fairly accurate for life predictions for aluminum, it is shown to poorly represent the behavior of stainless steel, especially in prestrained and high-low step tests, in load control. In order to account for prior deformation effects and achieve accurate fatigue life predictions for stainless steel, parameters including both stress and strain terms are required. The Smith-Watson-Topper and Fatemi-Socie approaches, as such parameters, are shown to correlate most test data fairly accurately. For damage accumulation under variable amplitude loading, the linear damage rule associated with strain-life or stress-life curves can lead to inaccurate fatigue life predictions, especially for materials presenting strong deformation memory effect, such as stainless steel 304L. The inadequacy of this method is typically attributed to the linear damage rule itself. On the contrary, this study demonstrates that damage accumulation using the linear damage rule can be accurate, provided that the linear damage rule is used in conjunction with parameters including both stress and strain terms. By including both loading history and response of the material in damage quantification, shortcomings of the commonly used linear damage rule approach can be circumvented in an effective manner. In addition, cracking behavior was also analyzed under various loading conditions. Results on microcrack initiation and propagation are presented in relation to deformation and fatigue behaviors of the materials. Microcracks were observed to form during the first few percent of life, indicating that most of the fatigue life of smooth specimens is spent in microcrack formation and growth. Analyses of fractured specimens showed that microcrack formation and growth is dependent on the loading history, and less important in aluminum than stainless steel 304L, due to the higher toughness of this latter material.
Assessing fatigue in inflammatory bowel disease: comparison of three fatigue scales.
Norton, C; Czuber-Dochan, W; Bassett, P; Berliner, S; Bredin, F; Darvell, M; Forbes, A; Gay, M; Ream, E; Terry, H
2015-07-01
Fatigue is commonly reported by patients with inflammatory bowel disease (IBD), both in quiescent and active disease. Few fatigue scales have been tested in IBD. To assess three fatigue assessment scales in IBD and to determine correlates of fatigue. Potential participants (n = 2131) were randomly selected from an IBD organisation's members' database; 605 volunteered and were posted three fatigue scales: Inflammatory Bowel Disease Fatigue scale, Multidimensional Fatigue Inventory and Multidimensional Assessment Fatigue scale and questionnaires assessing anxiety, depression, quality of life (QoL) and IBD activity. The questionnaires were tested for stability over time with another group (n = 70) of invited participants. Internal consistency was measured by Cronbach's alpha and test-retest reliability by the intraclass correlation coefficient (ICC). Four hundred and sixty-five of 605 (77%) questionnaires were returned; of 70 invited, 48/70 returned test (68.6%) and 41/70 (58.6%) returned retest. The three scales are highly correlated (P < 0.001). Test-retest suggests reasonable agreement with ICC values between 0.65 and 0.84. Lower age, female gender, IBD diagnosis, anxiety, depression and QoL were associated with fatigue (P < 0.001) on univariable analysis. However, on multivariable analysis only depression and low QoL were consistently associated with fatigue, while female gender was associated on most scales. IBD diagnosis, age and other factors were not consistently associated with severity or impact of fatigue once other variables were controlled for. All three fatigue scales are likely to measure IBD fatigue adequately. Responsiveness to change has not been tested. Depression, poorer QoL and probably female gender are the major associations of fatigue in IBD. © 2015 John Wiley & Sons Ltd.
Locomotor Muscle Fatigue Does Not Alter Oxygen Uptake Kinetics during High-Intensity Exercise.
Hopker, James G; Caporaso, Giuseppe; Azzalin, Andrea; Carpenter, Roger; Marcora, Samuele M
2016-01-01
The [Formula: see text] slow component ([Formula: see text]) that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre-fatigue condition) or rest for 33 min (control condition) according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-s maximal sprints at a fixed pedaling cadence of 90 rev·min -1 . Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE) were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and [Formula: see text] determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue ( P = 0.03), the [Formula: see text] was not significantly different between the pre-fatigue (464 ± 301 mL·min -1 ) and the control (556 ± 223 mL·min -1 ) condition ( P = 0.50). Blood lactate response was not significantly different between conditions ( P = 0.48) but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition ( P < 0.01) suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the [Formula: see text] kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the [Formula: see text] is strongly associated with locomotor muscle fatigue.
Locomotor Muscle Fatigue Does Not Alter Oxygen Uptake Kinetics during High-Intensity Exercise
Hopker, James G.; Caporaso, Giuseppe; Azzalin, Andrea; Carpenter, Roger; Marcora, Samuele M.
2016-01-01
The V˙O2 slow component (V˙O2sc) that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre-fatigue condition) or rest for 33 min (control condition) according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-s maximal sprints at a fixed pedaling cadence of 90 rev·min−1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE) were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and V˙O2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03), the V˙O2sc was not significantly different between the pre-fatigue (464 ± 301 mL·min−1) and the control (556 ± 223 mL·min−1) condition (P = 0.50). Blood lactate response was not significantly different between conditions (P = 0.48) but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01) suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the V˙O2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the V˙O2sc is strongly associated with locomotor muscle fatigue. PMID:27790156
Isothermal and thermal-mechanical fatigue of VVER-440 reactor pressure vessel steels
NASA Astrophysics Data System (ADS)
Fekete, Balazs; Trampus, Peter
2015-09-01
The fatigue life of the structural materials 15Ch2MFA (CrMoV-alloyed ferritic steel) and 08Ch18N10T (CrNi-alloyed austenitic steel) of VVER-440 reactor pressure vessel under completely reserved total strain controlled low cycle fatigue tests were investigated. An advanced test facility was developed for GLEEBLE-3800 physical simulator which was able to perform thermomechanical fatigue experiments under in-service conditions of VVER nuclear reactors. The low cycle fatigue results were evaluated with the plastic strain based Coffin-Manson law, and plastic strain energy based model as well. It was shown that both methods are able to predict the fatigue life of reactor pressure vessel steels accurately. Interrupted fatigue tests were also carried out to investigate the kinetic of the fatigue evolution of the materials. On these samples microstructural evaluation by TEM was performed. The investigated low cycle fatigue behavior can provide reference for remaining life assessment and lifetime extension analysis.
Fatigue, Creep-Fatigue, and Thermomechanical Fatigue Life Testing of Alloys
NASA Technical Reports Server (NTRS)
Halford, Gary R.; Lerch, Bradley A.; McGaw, Michael A.
2000-01-01
The fatigue crack initiation resistance of an alloy is determined by conducting a series of tests over a range of values of stress amplitude or strain range. The observed number of cycles to failure is plotted against the stress amplitude or strain range to obtain a fatigue curve. The fatigue properties quoted for an alloy are typically the constants used in the equation(s) that describe the fatigue curve. Fatigue lives of interest may be as low as 10(exp 2) or higher than 10(exp 9) cycles. Because of the enormous scatter associated with fatigue, dozens of tests may be needed to confidently establish a fatigue curve, and the cost may run into several thousands of dollars. To further establish the effects on fatigue life of the test temperature, environment, alloy condition, mean stress effects, creep-fatigue effects, thermomechanical cycling, etc. requires an extraordinarily large and usually very costly test matrix. The total effort required to establish the fatigue resistance of an alloy should not be taken lightly. Fatigue crack initiation tests are conducted on relatively small and presumed to be initially crack-free, samples of an alloy that are intended to be representative of the alloy's metallurgical and physical condition. Generally, samples are smooth and have uniformly polished surfaces within the test section. Some may have intentionally machined notches of well-controlled geometry, but the surface at the root of the notch is usually not polished. The purpose of polishing is to attain a reproducible surface finish. This is to eliminate surface finish as an uncontrolled variable. Representative test specimen geometries will be discussed later. Test specimens are cyclically loaded until macroscopically observable cracks initiate and eventually grow to failure. Normally, the fatigue failure life of a specimen is defined as the number of cycles to separation of the specimen into two pieces. Alternative definitions are becoming more common, particularly for low-cycle fatigue testing, wherein some prescribed indication of impending failure due to cracking is adopted. Specific criteria will be described later. As a rule, cracks that develop during testing are not measured nor are the test parameters intentionally altered owing to the presence of cracking.
Choi, Mi Son; Lee, Eun Ja
2015-08-01
To identify the effects of foot reflexology massage on fatigue, stress and depression of postpartum women. A nonequivalent control group pre-post design was used. A total of 70 women in a postpartum care center were recruited and were assigned to the experimental group (35) or control group (35). Foot reflexology massage was provided to the experimental group once a day for three days. Data were collected before and after the intervention program which was carried out from December, 2013 to February, 2014. Data were analyzed using Chi-square test, Fisher's exact test, and t-test. The level of fatigue in the experimental group was significantly lower than the control group (t=-2.74, p=.008). The level of cortisol in the urine of women in the experimental group was significantly lower than the control group (t=-2.19, p=.032). The level of depression in the experimental group was significantly lower than the control group (t=-3.00, p=.004). The results show that the foot reflexology massage is an effective nursing intervention to relieve fatigue, stress, and depression for postpartum women.
High temperature fatigue behavior of tungsten copper composites
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Kim, Yong-Suk; Gabb, Timothy P.
1989-01-01
The high temperature fatigue behavior of a 9 vol percent, tungsten fiber reinforced copper matrix composite was investigated. Load-controlled isothermal fatigue experiments at 260 and 560 C and thermomechanical fatigue (TMF) experiments, both in phase and out of phase between 260 and 560 C, were performed. The stress-strain response displayed considerable inelasticity under all conditions. Also, strain ratcheting was observed during all the fatigue experiments. For the isothermal fatigue and in-phase TMF tests, the ratcheting was always in a tensile direction, continuing until failure. The ratcheting during the out-of-phase TMF test shifted from a tensile direction to a compressive direction. This behavior was thought to be associated with the observed bulging and the extensive cracking of the out-of-phase specimen. For all cases, the fatigue lives were found to be controlled by damage to the copper matrix. Grain boundary cavitation was the dominant damage mechanism of the matrix. On a stress basis, TMF loading reduced lives substantially, relative to isothermal cycling. In-phase cycling resulted in the shortest lives, and isothermal fatigue at 260 C, the longest.
The effect of weld porosity on the cryogenic fatigue strength of ELI grade Ti-5Al-2.5Sn
NASA Technical Reports Server (NTRS)
Rogers, P. R.; Lambdin, R. C.; Fox, D. E.
1992-01-01
The effect of weld porosity on the fatigue strength of ELI grade Ti-5Al-2.5Sn at cryogenic temperature was determined. A series of high cycle fatigue (HCF) and tensile tests were performed at -320 F on specimens made from welded sheets of the material. All specimens were tested with weld beads intact and some amount of weld offset. Specimens containing porosity and control specimens containing no porosity were tested. Results indicate that for the weld configuration tested, the fatigue life of the material is not affected by the presence of spherical embedded pores.
Development of a powered outdoor sealant fatigue test apparatus
Steven Lacher; R. Sam Williams; Corey Halpin; Christopher White
2005-01-01
This chapter describes a new cyclic fatigue test apparatus (CFTA) developed at the USDA Forest Service, Forest Products Laboratory. The new CFTA is computer controlled and powered by electric linear actuators. Computer control allows the CFTA to subject specimens to specific strain/time profiles or replicate input strain data in real time from thermal and/or moisture...
A computerized test system for thermal-mechanical fatigue crack growth
NASA Technical Reports Server (NTRS)
Marchand, N.; Pelloux, R. M.
1986-01-01
A computerized testing system to measure fatigue crack growth under thermal-mechanical fatigue conditions is described. Built around a servohydraulic machine, the system is capable of a push-pull test under stress-controlled or strain-controlled conditions in the temperature range of 25 to 1050 C. Temperature and mechanical strain are independently controlled by the closed-loop system to simulate the complex inservice strain-temperature relationship. A d-c electrical potential method is used to measure crack growth rates. The correction procedure of the potential signal to take into account powerline and RF-induced noises and thermal changes is described. It is shown that the potential drop technique can be used for physical mechanism studies and for modelling crack tip processes.
NASA Technical Reports Server (NTRS)
Jones, David J.; Kurath, Peter
1988-01-01
Fully reversed uniaxial strain controlled fatigue tests were performed on smooth cylindrical specimens made of 304 stainless steel. Fatigue life data and cracking observations for uniaxial tests were compared with life data and cracking behavior observed in fully reversed torsional tests. It was determined that the product of maximum principle strain amplitude and maximum principle stress provided the best correlation of fatigue lives for these two loading conditions. Implementation of this parameter is in agreement with observed physical damage and it accounts for the variation of stress-strain response, which is unique to specific loading conditions. Biaxial fatigue tests were conducted on tubular specimens employing both in-phase and out-of-phase tension torsion cyclic strain paths. Cracking observations indicated that the physical damage which occurred in the biaxial tests was similar to the damage observed in uniaxial and torsional tests. The Smith, Watson, and Topper parameter was then extended to predict the fatigue lives resulting from the more complex loading conditions.
Flachenecker, Peter; Meissner, Heike; Frey, Rebecca; Guldin, Wolfgang
2017-01-01
Attentional deficits may be pathophysiologically relevant in MS-associated fatigue. Thirty MS patients with fatigue and attentional deficits in neuropsychological testing participated in this randomized, placebo-controlled, double-blind trial. The intervention group (IG; n = 14) was treated with 10 h of computerized, specific neuropsychological training performing simple reaction time tasks, whereas the control group (CG; n = 16) also runs through computerized, but unspecific neuropsychological training using tasks without time components. The subjective feeling of fatigue was assessed with the Würzburg Fatigue Inventory for Multiple Sclerosis (WEIMuS) questionnaire, and testing of alertness was used as an objective measure at baseline and after the 2-week study period. Reaction times of alertness were significantly decreased in IG but not CG after 2 weeks. The subjective feeling of fatigue was ameliorated in both groups but more pronounced in IG. Effect sizes were below 0.7 for alertness and WEIMuS scores in CG but large and clinically meaningful in IG for both measures. Our pilot study suggests that neuropsychological training of attention may improve both measures of fatigue. The parallel improvement of attentional deficits and subjective fatigue after specific neuropsychological training support previous findings that fatigue may be at least partially caused by impaired intensity of attention. © 2017 S. Karger AG, Basel.
NASA Technical Reports Server (NTRS)
Krempl, Erhard; An, Deukman
1991-01-01
Fatigue tests conducted with and without internal pressure have been found to possess approximately the same fatigue life as (+/-45)s graphite/epoxy tubes for zero-to-tension axial load-controlled conditions on an axial torsion servohydraulic apparatus. These tests therefore cannot be considered as confirmations of the suspected detrimental effect of interlaminar tensile stresses on the fatigue performance of thin-walled tubes. The addition of 90-deg plies on both the inside and the outside is found to significantly improve the tubes' static and fatigue strengths.
Mental Fatigue and Physical and Cognitive Performance During a 2-Bout Exercise Test.
Vrijkotte, Susan; Meeusen, Romain; Vandervaeren, Cloe; Buyse, Luk; Cutsem, Jeroen van; Pattyn, Nathalie; Roelands, Bart
2018-04-01
The 2-bout exercise protocol has been developed to diagnose nonfunctional overreaching and the "overtraining syndrome." It consists of 2 maximal exercise bouts separated by 4 hours. Mental fatigue negatively influences performance, but the effects of its occurrence during the 2-bout exercise protocol have never been investigated. The aim of this study was to examine whether mental fatigue (induced during the rest period) influences physical and cognitive performance during/after the second exercise bout of the 2-bout exercise protocol. Nine healthy, well-trained male cyclists participated in a single-blind, randomized, placebo-controlled crossover study. The intervention consisted of either 1.5-hour rest (control) or performing a computer-based Stroop task to induce mental fatigue. Cognitive (Eriksen Flanker task), physiological (lactate, maximum heart rate, and maximum wattage), and subjective data (mental fatigue-visual analog scale, Profile of Mood States, and rating of perceived exertion) were gathered. Ratings of fatigue, tension, and mental fatigue were affected in the mental fatigue condition (P < .05). Neither physiological nor cognitive differences were found between conditions. Ratings of mental fatigue were already affected after the first maximum exercise test (P < .05). Neither physical nor cognitive performance was affected by mental fatigue, but subjective ratings did reveal significant differences. It is recommended to exclude mentally challenging tasks during the 2-bout exercise protocol rest period to ascertain unaffected subjective test results. This study should be repeated in athletes diagnosed with nonfunctional overreaching/overtraining syndrome.
Self-reported post-exertional fatigue in Gulf War veterans: roles of autonomic testing
Li, Mian; Xu, Changqing; Yao, Wenguo; Mahan, Clare M.; Kang, Han K.; Sandbrink, Friedhelm; Zhai, Ping; Karasik, Pamela A.
2014-01-01
To determine if objective evidence of autonomic dysfunction exists from a group of Gulf War veterans with self-reported post-exertional fatigue, we evaluated 16 Gulf War ill veterans and 12 Gulf War controls. Participants of the ill group had self- reported, unexplained chronic post-exertional fatigue and the illness symptoms had persisted for years until the current clinical study. The controls had no self-reported post-exertional fatigue either at the time of initial survey nor at the time of the current study. We intended to identify clinical autonomic disorders using autonomic and neurophysiologic testing in the clinical context. We compared the autonomic measures between the 2 groups on cardiovascular function at both baseline and head-up tilt, and sudomotor function. We identified 1 participant with orthostatic hypotension, 1 posture orthostatic tachycardia syndrome, 2 distal small fiber neuropathy, and 1 length dependent distal neuropathy affecting both large and small fiber in the ill group; whereas none of above definable diagnoses was noted in the controls. The ill group had a significantly higher baseline heart rate compared to controls. Compound autonomic scoring scale showed a significant higher score (95% CI of mean: 1.72–2.67) among ill group compared to controls (0.58–1.59). We conclude that objective autonomic testing is necessary for the evaluation of self-reported, unexplained post-exertional fatigue among some Gulf War veterans with multi-symptom illnesses. Our observation that ill veterans with self-reported post-exertional fatigue had objective autonomic measures that were worse than controls warrants validation in a larger clinical series. PMID:24431987
A data acquisition and control program for axial-torsional fatigue testing
NASA Technical Reports Server (NTRS)
Kalluri, Sreeramesh; Bonacuse, Peter J.
1989-01-01
A computer program was developed for data acquisition and control of axial-torsional fatigue experiments. The multitasked, interrupt-driven program was written in Pascal and Assembly. This program is capable of dual-channel control and six-channel data acquisition. It can be utilized to perform inphase and out-of-phase axial-torsional isothermal fatigue or deformation experiments. The program was successfully used to conduct inphase axial-torsional fatigue experiments on 304 stainless steel at room temperature and on Hastelloy X at 800 C. The details of the software and some of the results generated to date are presented.
Soysal Tomruk, Melda; Uz, Muhammed Zahid; Kara, Bilge; İdiman, Egemen
2016-05-01
Decreased postural control, sensory integration deficits and fatigue are important problems that cause functional impairments in patients with multiple sclerosis (pwMS). To examine the effect of modified clinical Pilates exercises on sensory interaction and balance, postural control and fatigue in pwMS. Eleven patients with multiple sclerosis and 12 healthy matched controls were recruited in this study. Limits of stability and postural stability tests were used to evaluate postural control by Biodex Balance System and sensory interaction assessed. Fatigue was assessed by Modified Fatigue Impact Scale. Pilates exercises were applied two times a week for 10 weeks and measurements were repeated to pwMS after exercise training. Postural control and fatigue (except psychosocial parameter) of pwMS were significantly worser than healthy controls (p<0.05). Significant improvements occurred in sensory interaction (eyes open, foam surface) and total, physical and cognitive scores of fatigue after 10-week modified clinical Pilates training (p<0.05). No significant changes were detected in postural control after the pilates exercises (p>0.05). Ten-week Pilates training is effective to improve sensory interaction and to decrease fatigue. Pilates exercises can be applied safely in ambulatory pwMS for enhance sensory interaction and balance and combat fatigue. More investigations are needed. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chan, Kwai S.; Koike, Marie; Mason, Robert L.; Okabe, Toru
2013-02-01
Additive layer deposition techniques such as electron beam melting (EBM) and laser beam melting (LBM) have been utilized to fabricate rectangular plates of Ti-6Al-4V with extra low interstitial (ELI) contents. The layer-by-layer deposition techniques resulted in plates that have different surface finishes which can impact significantly on the fatigue life by providing potential sites for fatigue cracks to initiate. The fatigue life of Ti-6Al-4V ELI alloys fabricated by EBM and LBM deposition techniques was investigated by three-point testing of rectangular beams of as-fabricated and electro-discharge machined surfaces under stress-controlled conditions at 10 Hz until complete fracture. Fatigue life tests were also performed on rolled plates of Ti-6Al-4V ELI, regular Ti-6Al-4V, and CP Ti as controls. Fatigue surfaces were characterized by scanning electron microscopy to identify the crack initiation site in the various types of specimen surfaces. The fatigue life data were analyzed statistically using both analysis of variance techniques and the Kaplan-Meier survival analysis method with the Gehan-Breslow test. The results indicate that the LBM Ti-6Al-4V ELI material exhibits a longer fatigue life than the EBM counterpart and CP Ti, but a shorter fatigue life compared to rolled Ti-6Al-4V ELI. The difference in the fatigue life behavior may be largely attributed to the presence of rough surface features that act as fatigue crack initiation sites in the EBM material.
Laboratory Study on the Fatigue Resistance of Asphaltic Concrete Containing Titanium Dioxide
NASA Astrophysics Data System (ADS)
Buhari, Rosnawati; Ezree Abdullah, Mohd; Khairul Ahmad, Mohd; Azhar Tajudin, Saiful; Khatijah Abu Bakar, Siti
2018-03-01
This study aims to evaluate the fatigue performance of modified asphalt mixture using Indirect Tensile Fatigue Test. Titanium Dioxide (TiO2) powder in a form of rutile was used for producing asphalt concrete with lower mixing and compaction temperature compared to conventional hot mix asphalt without reducing its physical and mechanical also resistance to fatigue. The characteristic of the asphalt and modified asphalt was evaluated using penetration test, softening test and rotational viscosity test. Titanium dioxide of 2%, 4%, 6%, 8% and 10% by weight of asphalt has been incorporated into unaged 80/100 asphalt mix in order to improvise its performance and to fulfill the objectives of this experimental study. As a result, TiO2 as an additive is potential to decrease the penetration and increasing the softening point of the asphalt. In terms of fatigue performance testing, addition TiO2 additive does help in improving the fatigue properties as it shows greater result than the control asphalt. In conclusion, TiO2 is great in improving fatigue properties.
NASA Technical Reports Server (NTRS)
Conway, J. B.; Stentz, R. H.; Berling, J. T.
1973-01-01
The low-cycle fatigue characteristics of smooth bar and notched bar specimens (hourglass shape) of zirconium-copper, 1/2 Hard, material (R-2 Series) were evaluated at room temperature in axial strain control. Over the fatigue life range from about 300 to 3000 cycles the ratio of fatigue life for smooth bar to fatigue life for notched bar remained constant at a value of about 6.0. Some additional hold-time data for the R-2 alloy tested in argon at 538 C are reported. An analysis of the relaxation data obtained in these hold-time tests is also reported and it is shown that these data yield a fairly consistent correlation in terms of instantaneous stress rate divided by instantaneous stress. Two thermal-mechanical strain cycling tests were also performed using a cyclic frequency of 4.5 cycles per hour and a temperature cycling interval from 260 to 538 C. The fatigue life values in these tests were noticeably lower than that observed in isothermal tests at 538 C.
Effects of sour crude oil on fatigue properties of steel plates for shipbuilding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouchi, H.; Kobayashi, J.; Ishikawa, T.
1994-12-31
The concentration of diffusible hydrogen introduced into steel was measured, and fatigue crack growth tests and fatigue life tests were carried out in sour crude oil containing a high concentration of hydrogen sulfide and under electrolytic hydrogen-charging conditions in neutral solution, using a high strength steel produced by the thermo-mechanical control process (TMCP) and a mild steel which are steels for hull plates. Comparison of the results demonstrated that a very small amount of hydrogen such as that introduced into steel from sour crude oil under atmospheric pressure accelerated the fatigue crack growth in the high {Delta}K regime and shortenedmore » the fatigue life in the high stress range region, but did not shorten the fatigue life in the low stress region. The electrolytic hydrogen-charging condition appeared to be appropriate as a fatigue-crack-growth test environment to simulate sour crude oil. The deterioration of fatigue characteristics of the TMCP high strength steel was similar with that of the mild steel.« less
Novel Electrochemical Test Bench for Evaluating the Functional Fatigue Life of Biomedical Alloys
NASA Astrophysics Data System (ADS)
Ijaz, M. F.; Dubinskiy, S.; Zhukova, Y.; Korobkova, A.; Pustov, Y.; Brailovski, V.; Prokoshkin, S.
2017-08-01
The aim of the present work was first to develop and validate a test bench that simulates the in vitro conditions to which the biomedical implants will be actually subjected in vivo. For the preliminary application assessments, the strain-controlled fatigue tests of biomedically pure Ti and Ti-Nb-Zr alloy in simulated body fluid were undertaken. The in situ open-circuit potential measurements from the test bench demonstrated a strong dependence on the dynamic cycling and kind of material under testing. The results showed that during fatigue cycling, the passive oxide film formed on the surface of Ti-Nb-Zr alloy was more resistant to fatigue degradation when compared with pure Ti. The Ti-Nb-Zr alloy exhibited prolonged fatigue life when compared with pure Ti. The fractographic features of both materials were also characterized using scanning electron microscopy. The electrochemical results and the fractographic evidence confirmed that the prolonged functional fatigue life of the Ti-Nb-Zr alloy is apparently ascribable to the reversible martensitic phase transformation.
2013-01-01
Background The purpose of the present study was to compare dynamic muscle strength, functional performance, fatigue, and quality of life in premenopausal systemic lupus erythematosus (SLE) patients with low disease activity versus matched-healthy controls and to determine the association of dynamic muscle strength with fatigue, functional performance, and quality of life in SLE patients. Methods We evaluated premenopausal (18–45 years) SLE patients with low disease activity (Systemic lupus erythematosus disease activity index [SLEDAI]: mean 1.5 ± 1.2). The control (n = 25) and patient (n = 25) groups were matched by age, physical characteristics, and the level of physical activities in daily life (International Physical Activity Questionnaire IPAQ). Both groups had not participated in regular exercise programs for at least six months prior to the study. Dynamic muscle strength was assessed by one-repetition maximum (1-RM) tests. Functional performance was assessed by the Timed Up and Go (TUG), in 30-s test a chair stand and arm curl using a 2-kg dumbbell and balance test, handgrip strength and a sit-and-reach flexibility test. Quality of life (SF-36) and fatigue were also measured. Results The SLE patients showed significantly lower dynamic muscle strength in all exercises (leg press 25.63%, leg extension 11.19%, leg curl 15.71%, chest press 18.33%, lat pulldown 13.56%, 1-RM total load 18.12%, P < 0.001-0.02) compared to the controls. The SLE patients also had lower functional performance, greater fatigue and poorer quality of life. In addition, fatigue, SF-36 and functional performance accounted for 52% of the variance in dynamic muscle strength in the SLE patients. Conclusions Premenopausal SLE patients with low disease activity showed lower dynamic muscle strength, along with increased fatigue, reduced functional performance, and poorer quality of life when compared to matched controls. PMID:24011222
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanders, B.P.; Mall, S.; Dennis, L.B.
1997-10-01
A study was conducted to investigate the fatigue behavior of a cross-ply metal matrix composite subjected to fully-reversed, strain-controlled fatigue cycling at elevated temperature. The stress-strain response, maximum and minimum stresses, and modulus during cycling were analyzed to characterize the macro-mechanical behavior. Additionally, microscopy and fractography were conducted to identify damage mechanisms. Damage always initiated in the 90 deg plies, but the governing factor in the fatigue life was damage in the 0 deg plies. The dominant failure mode was fracturing of fibers in the 0 deg plies when the maximum strain was greater than 0.55%, but the dominant failuremore » mode was matrix cracking when the maximum strain was less than 0.55%. Combining the fatigue life data with the macro-mechanical and microscopic observations, a fatigue life diagram was developed and partitioned into three regions. These regions showed relationships between the maximum applied strain and the dominant damage mechanisms. Also, on a strain range basis, the fatigue lives of the specimens tested under the strain-controlled mode in this study were compared with its counterpart under the load-controlled mode of the previous study. It was found that the fatigue lives for these two conditions were the same within the experimental scatter. The MMC tested in this investigation was the Ti-15V-3Cr-3Al-3Sn titanium alloy reinforced with 36 volume percent of silicon carbide fibers (SCS-6).« less
Field test and finite element of I-345 bridge in Dallas.
DOT National Transportation Integrated Search
2009-07-01
This report documents a field test to determine the stresses at areas where fatigue cracks had formed in the : bridges. Two bridges were instrumented and subjected to controlled truck traffic. In addition, the service fatigue : stresses were evaluate...
Influence of neutron irradiation at 430$deg;C on the fatigue properties of SA 316L steel
NASA Astrophysics Data System (ADS)
Vandermeulen, W.; Hendrix, W.; Massaut, V.; Van de Velde, J.
1988-07-01
Fatigue tests have been carried out at 430°C on hour-glass shaped specimens of the CEC reference heat of SA 316L stainless steel. The tests were performed under constant total axial strain control with a triangular fully reversed wave shape at frequencies of 0.5, 0.05 and 0.005 Hz. Specimens irradiated at 430°C to doses of 9-12 dpa and helium contents of 80 to 145 appm showed a fatigue life reduction by about a factor of two, compared to unirradiated specimens. The cyclic stress is found to be strongly increased by the irradiation. The test frequency influences the fatigue hardening slightly but it does not affect the fatigue life.
Fatigue Behavior of AM60B Subjected to Variable Amplitude Loading
NASA Astrophysics Data System (ADS)
Kang, H.; Kari, K.; Khosrovaneh, A. K.; Nayaki, R.; Su, X.; Zhang, L.; Lee, Y.-L.
Magnesium alloys are considered as an alternative material to reduce vehicle weight due to their weight which are 33% lighter than aluminum alloys. There has been a significant expansion in the applications of magnesium alloys in automotives components in an effort to improve fuel efficiency through vehicle mass reduction. In this project, a simple front shock tower of passenger vehicle is constructed with various magnesium alloys. To predict the fatigue behavior of the structure, fatigue properties of the magnesium alloy (AM60B) were determined from strain controlled fatigue tests. Notched specimens were also tested with three different variable amplitude loading profiles obtained from the shock tower of the similar size of vehicle. The test results were compared with various fatigue prediction results. The effect of mean stress and fatigue prediction method were discussed.
NASA Astrophysics Data System (ADS)
Hojo, M.; Osawa, K.; Adachi, T.; Inoue, Y.; Osamura, K.; Ochiai, S.; Ayai, N.; Hayashi, K.
2010-11-01
Tensile strain tolerance of the critical current in (Bi,Pb)2Sr2Ca2Cu3Ox (Bi2223) composite superconductor is dramatically improved when the tape is laminated with stainless steel. For practical applications, it is important to understand whether this reinforcement by lamination is effective under fatigue loading. In the present study, we carried out fatigue tests in LN2 and measured the critical current at the specific fatigue cycles to clarify the strain tolerance of the critical current in stainless steel-laminated drastically innovative Bi2223 (DI-BSCCO®) tapes. The fatigue tests were carried out using a computer-controlled 10 kN servo-hydraulic fatigue testing machine with a load cell capacity of 2.5 kN. Tests under static loading showed that the irreversible stress at which the critical current is reduced by 1% from the original value (tensile stress at Ic/Ic0 = 0.99) was 315 MPa when measured at unloading state. The present fatigue tests results indicated that the critical current was maintained at over 98% of the original value at unloading state after stress cycles of 106 when the static irreversible stress was selected as the maximum stress under fatigue loading. Thus, laminated DI-BSCCO tapes showed excellent mechanical properties even under fatigue loading.
Krabbe, David; Ellbin, Susanne; Nilsson, Michael; Jonsdottir, Ingibjörg H; Samuelsson, Hans
2017-07-01
Cognitive impairment has frequently been shown in patients who seek medical care for stress-related mental health problems. This study aims to extend the current knowledge of cognitive impairments in these patients by focusing on perceived fatigue and effects of distraction during cognitive testing. Executive function and attention were tested in a group of patients with stress-related exhaustion (n = 25) and compared with healthy controls (n = 25). Perceived fatigue was measured before, during and after the test session, and some of the tests were administered with and without standardized auditory distraction. Executive function and complex attention performance were poorer among the patients compared to controls. Interestingly, their performance was not significantly affected by auditory distraction but, in contrast to the controls, they reported a clear-cut increase in mental tiredness, during and after the test session. Thus, patients with stress-related exhaustion manage to perform during distraction but this was achieved at a great cost. These findings are discussed in terms of a possible tendency to adopt a high-effort approach despite cognitive impairments and the likelihood that such an approach will require increased levels of effort, which can result in increased fatigue. We tentatively conclude that increased fatigue during cognitive tasks is a challenge for patients with stress-related exhaustion and plausibly of major importance when returning to work demanding high cognitive performance.
NASA Astrophysics Data System (ADS)
Solomon, H. D.; Amzallag, C.; Vallee, A. J.; DeLair, R. E.
This is a study of the 107 cycle fatigue limit of Type 304L Stainless Steel, as measured in fully reversed (R=-1) load-controlled tests, at 150°C and 300°C, in air and PWR water. The staircase method was used to determine the fatigue limit. The tests run here utilized a cycle frequency of 1.818Hz and are compared to other tests from the literature that were run at 30Hz. The fatigue limit measured in the tests run at the high frequency was higher than that measured here. This is explained by measurements of the strain developed during cycling, using the different cycle frequencies. The tests run at the higher frequencies yielded lower strains for a given stress and, as expected, this resulted in higher fatigue limits. Using 107 cycles to define a run-out also led to a lower fatigue limit. These results are important as most previous fatigue limit measurements utilized 106 cycles or less to define a run-out, and when lives as long as 107 cycles are used the tests are generally run at high cycle frequencies, thus leading to higher fatigue limits than those measured here.
Guo, Wei; Ren, Jie; Wang, Biye; Zhu, Qin
2015-01-01
The purpose of this study was to investigate whether listening to relaxing music would help reduce mental fatigue and to maintain performance after a continuous performance task. The experiment involved two fatigue evaluation phases carried out before and after a fatigue inducing phase. A 1-hour AX-continuous performance test was used to induce mental fatigue in the fatigue-inducing phase, and participants' subjective evaluation on the mental fatigue, as well as their neurobehavioral performance in a Go/NoGo task, were measured before and after the fatigue-inducing phase. A total of 36 undergraduate students (18-22 years) participated in the study and were randomly assigned to the music group and control group. The music group performed the fatigue-inducing task while listening to relaxing music, and the control group performed the same task without any music. Our results revealed that after the fatigue-inducing phase, (a) the music group demonstrated significantly less mental fatigue than control group, (b) reaction time significantly increased for the control group but not for the music group, (c) larger Go-P3 and NoGo-P3 amplitudes were observed in the music group, although larger NoGo-N2 amplitudes were detected for both groups. These results combined to suggest that listening to relaxing music alleviated the mental fatigue associated with performing an enduring cognitive-motor task.
Fatigue of DIN 1.4914 martensitic stainless steel in a hydrogen environment
NASA Astrophysics Data System (ADS)
Shakib, J. I.; Ullmaier, H.; Little, E. A.; Faulkner, R. G.; Schmilz, W.; Chung, T. E.
1994-09-01
Fatigue tests at room temperature in vacuum, air and hydrogen have been carried out on specimens of DIN 1.4914 martensitic stainless steel in load-controlled, push-pull type experiments. Fatigue lifetimes in hydrogen are significantly lower than in both vacuum and air and the degradation is enhanced by lowering the test frequency or introducing hold times into the tension half-cycle. Fractographic examinations reveal hydrogen embrittlement effects in the form of internal cracking between fatigue striations together with surface modifications, particularly at low stress amplitudes. It is suggested that gaseous hydrogen can influence both fatigue crack initiation and propagation events in martensitic steels.
Tensile and fatigue behavior of tungsten/copper composites
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Gabb, Timothy P.; Kim, Y. S.
1989-01-01
Work on W/Cu unidirectional composites was initiated to study the behavior of this ductile-ductile composite system under thermomechanical fatigue and to examine the applicability of fatigue-life prediction methods for thermomechanical fatigue of this metal matrix composite. The first step was to characterize the tensile behavior of four ply, 10 vol. percent W/Cu plates at room and elevated temperatures. Fatigue tests were conducted in load control on 0 degree specimens at 260 C. The maximum cyclic stress was varied but the minimum cyclic stress was kept constant. All tests were performed in vacuum. The strain at failure increased with increasing maximum cyclic stress.
Cryogenic properties of dispersion strengthened copper for high magnetic fields
NASA Astrophysics Data System (ADS)
Toplosky, V. J.; Han, K.; Walsh, R. P.; Swenson, C. A.
2014-01-01
Cold deformed copper matrix composite conductors, developed for use in the 100 tesla multi-shot pulsed magnet at the National High Magnetic Field Laboratory (NHMFL), have been characterized. The conductors are alumina strengthened copper which is fabricated by cold drawing that introduces high dislocation densities and high internal stresses. Both alumina particles and high density of dislocations provide us with high tensile strength and fatigue endurance. The conductors also have high electrical conductivities because alumina has limited solubility in Cu and dislocations have little scattering effect on conduction electrons. Such a combination of high strength and high conductivity makes it an excellent candidate over other resistive magnet materials. Thus, characterization is carried out by tensile testing and fully reversible fatigue testing. In tensile tests, the material exceeds the design criteria parameters. In the fatigue tests, both the load and displacement were measured and used to control the amplitude of the tests to simulate the various loading conditions in the pulsed magnet which is operated at 77 K in a non-destructive mode. In order to properly simulate the pulsed magnet operation, strain-controlled tests were more suitable than load controlled tests. For the dispersion strengthened coppers, the strengthening mechanism of the aluminum oxide provided better tensile and fatigue properties over convention copper.
NASA Technical Reports Server (NTRS)
Gyekenyesi, Andrew L.; Gastelli, Michael G.; Ellis, John R.; Burke, Christopher S.
1995-01-01
An experimental study was conducted to investigate the mechanical behavior of a T650-35/AMB21 eight-harness satin weave polymer composite system. Emphasis was placed on the development and refinement of techniques used in elevated temperature uniaxial PMC testing. Issues such as specimen design, gripping, strain measurement, and temperature control and measurement were addressed. Quasi-static tensile and fatigue properties (R(sub sigma) = 0.1) were examined at room and elevated temperatures. Stiffness degradation and strain accumulation during fatigue cycling were recorded to monitor damage progression and provide insight for future analytical modeling efforts. Accomplishments included an untabbed dog-bone specimen design which consistently failed in the gage section, accurate temperature control and assessment, and continuous in-situ strain measurement capability during fatigue loading at elevated temperatures. Finally, strain accumulation and stiffness degradation during fatigue cycling appeared to be good indicators of damage progression.
Thermomechanical Multiaxial Fatigue Testing Capability Developed
NASA Technical Reports Server (NTRS)
1996-01-01
Structural components in aeronautical gas turbine engines typically experience multiaxial states of stress under nonisothermal conditions. To estimate the durability of the various components in the engine, one must characterize the cyclic deformation and fatigue behavior of the materials used under thermal and complex mechanical loading conditions. To this end, a testing protocol and associated test control software were developed at the NASA Lewis Research Center for thermomechanical axial-torsional fatigue tests. These tests are to be performed on thin-walled, tubular specimens fabricated from the cobalt-based superalloy Haynes 188. The software is written in C and runs on an MS-DOS based microcomputer.
ERIC Educational Resources Information Center
Hockey, G. Robert J.; Earle, Fiona
2006-01-01
Two experiments tested the hypothesis that task-induced mental fatigue is moderated by control over work scheduling. Participants worked for 2 hr on simulated office work, with control manipulated by a yoking procedure. Matched participants were assigned to conditions of either high control (HC) or low control (LC). HC participants decided their…
Kim, Namhee; De Souza, Grace M.
2017-01-01
Objective To determine the effects of whitening strips on bovine dentin fatigue resistance and flexural strength in vitro. Materials and methods A total of eighty bovine dentin specimens (2x2x17mm) were treated with either: control glycerine gel on plastic film wrap or whitening strips containing 9.5% hydrogen peroxide. Treatment was applied for 30 minutes, twice a day, for 1- or 4-weeks. After the last treatment, ten specimens per group were randomly selected to undergo fatigue testing (106 cycles, 3Hz, 20N) while the other ten were subjected to flexural strength testing after ten days of storage in artificial saliva. Kaplan-Meier method with a log rank test, Wilcoxon test and Cox regression were used to assess fatigue test results (p<0.05). One-way ANOVA and Tukey’s tests were used to compare the flexural strength results (p<0.05). Results There were significant differences in survival during the fatigue test among the groups (p<0.001). Treatment (control or bleach) was a significant factor for specimen survival (p<0.001, Exp(B) = 33.45). There were significant differences in mean flexural strength (p<0.001). No significant difference was found between “1-wk control” and “4-wk control”. The mean flexural strength and fatigue resistance of the “4-wk bleach” were significantly lower than all the other groups. Conclusions The use of whitening strips reduced the fatigue resistance and flexural strength of bovine dentin in vitro. Until the effect of whitening strips on mechanical properties of human dentin is fully elucidated, it remains prudent to advise patients to avoid excessive direct use of whitening strips on dentin. PMID:28278191
A systems approach to solder joint fatigue in spacecraft electronic packaging
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.
1991-01-01
Differential expansion induced fatigue resulting from temperature cycling is a leading cause of solder joint failures in spacecraft. Achieving high reliability flight hardware requires that each element of the fatigue issue be addressed carefully. This includes defining the complete thermal-cycle environment to be experienced by the hardware, developing electronic packaging concepts that are consistent with the defined environments, and validating the completed designs with a thorough qualification and acceptance test program. This paper describes a useful systems approach to solder fatigue based principally on the fundamental log-strain versus log-cycles-to-failure behavior of fatigue. This fundamental behavior has been useful to integrate diverse ground test and flight operational thermal-cycle environments into a unified electronics design approach. Each element of the approach reflects both the mechanism physics that control solder fatigue, as well as the practical realities of the hardware build, test, delivery, and application cycle.
A wireless body measurement system to study fatigue in multiple sclerosis.
Yu, Fei; Bilberg, Arne; Stenager, Egon; Rabotti, Chiara; Zhang, Bin; Mischi, Massimo
2012-12-01
Fatigue is reported as the most common symptom by patients with multiple sclerosis (MS). The physiological and functional parameters related to fatigue in MS patients are currently not well established. A new wearable wireless body measurement system, named Fatigue Monitoring System (FAMOS), was developed to study fatigue in MS. It can continuously measure electrocardiogram, body-skin temperature, electromyogram and motions of feet. The goal of this study is to test the ability of distinguishing fatigued MS patients from healthy subjects by the use of FAMOS. This paper presents the realization of the measurement system including the design of both hardware and dedicated signal processing algorithms. Twenty-six participants including 17 MS patients with fatigue and 9 sex- and age-matched healthy controls were included in the study for continuous 24 h monitoring. The preliminary results show significant differences between fatigued MS patients and healthy controls. In conclusion, the FAMOS enables continuous data acquisition and estimation of multiple physiological and functional parameters. It provides a new, flexible and objective approach to study fatigue in MS, which can distinguish between fatigued MS patients and healthy controls. The usability and reliability of the FAMOS should however be further improved and validated through larger clinical trials.
Creep fatigue life prediction for engine hot section materials (isotropic)
NASA Technical Reports Server (NTRS)
Nelson, R. S.; Levan, G. W.; Schoendorf, J. F.
1992-01-01
A series of high temperature strain controlled fatigue tests have been completed to study the effects of thermomechanical fatigue, multiaxial loading, reactive environments, and imposed mean stresses. The baseline alloy used in these tests was cast B1900+Hf (with and without coatings); a small number of tests of wrought INCO 718 are also included. A strong path dependence was demonstrated during the thermomechanical fatigue testing, using in-phase, out-phase, and non-proportional (elliptical and 'dogleg') strain-temperature cycles. The multiaxial tests also demonstrated cycle path to be a significant variable, using both proportional and non-proportional tension-torsion loading. Environmental screening tests were conducted in moderate pressure oxygen and purified argon; the oxygen reduced the specimen lives by two, while the argon testing produced ambiguous data. Both NiCoCrAlY overlay and diffusion aluminide coatings were evaluated under isothermal and TMF conditions; in general, the lives of the coated specimens were higher that those of uncoated specimens. Controlled mean stress TMF tests showed that small mean stress changes could change initiation lives by orders of magnitude; these results are not conservatively predicted using traditional linear damage summation rules. Microstructures were evaluated using optical, SEM and TEM methods.
Thorndike, Frances P.; Ritterband, Lee M.; Gonder-Frederick, Linda A.; Lord, Holly R.; Ingersoll, Karen S.; Morin, Charles M.
2014-01-01
Objective Insomnia is frequently comorbid with other medical and psychological disorders. This secondary data analysis investigated whether an Internet-delivered cognitive behavioral therapy for insomnia (CBT-I) intervention could also reduce comorbid psychological and fatigue symptoms. Method Data from a pilot randomized controlled trial (RCT) testing the efficacy of Internet-delivered CBT-I relative to a waitlist control was used to examine changes in symptoms of depression, anxiety, mental health quality of life (QOL), and fatigue. Results Group by time interactions from repeated measures analyses revealed significant post intervention improvements in Internet participants (n = 22) relative to control participants (n = 22) on all psychological symptoms, mental health QOL, and fatigue. A small post hoc subsample of Internet participants with mild or moderate depression also showed large effect size changes in these constructs (depression, anxiety, mental health QOL, and fatigue). Conclusion Internet-delivered CBT-I appears to not only improve sleep but also reduce comorbid psychological and fatigue symptoms. PMID:24014057
Thorndike, Frances P; Ritterband, Lee M; Gonder-Frederick, Linda A; Lord, Holly R; Ingersoll, Karen S; Morin, Charles M
2013-10-01
Insomnia is frequently comorbid with other medical and psychological disorders. This secondary data analysis investigated whether an Internet-delivered cognitive behavioral therapy for insomnia (CBT-I) intervention could also reduce comorbid psychological and fatigue symptoms. Data from a pilot randomized controlled trial (RCT) testing the efficacy of Internet-delivered CBT-I relative to a waitlist control was used to examine changes in symptoms of depression, anxiety, mental health quality of life (QOL), and fatigue. Group by time interactions from repeated measures analyses revealed significant post intervention improvements in Internet participants (n = 22) relative to control participants (n = 22) on all psychological symptoms, mental health QOL, and fatigue. A small post hoc subsample of Internet participants with mild or moderate depression also showed large effect size changes in these constructs (depression, anxiety, mental health QOL, and fatigue). Internet-delivered CBT-I appears to not only improve sleep but also reduce comorbid psychological and fatigue symptoms. © 2013 Wiley Periodicals, Inc.
Real-time sensing of fatigue crack damage for information-based decision and control
NASA Astrophysics Data System (ADS)
Keller, Eric Evans
Information-based decision and control for structures that are subject to failure by fatigue cracking is based on the following notion: Maintenance, usage scheduling, and control parameter tuning can be optimized through real time knowledge of the current state of fatigue crack damage. Additionally, if the material properties of a mechanical structure can be identified within a smaller range, then the remaining life prediction of that structure will be substantially more accurate. Information-based decision systems can rely one physical models, estimation of material properties, exact knowledge of usage history, and sensor data to synthesize an accurate snapshot of the current state of damage and the likely remaining life of a structure under given assumed loading. The work outlined in this thesis is structured to enhance the development of information-based decision and control systems. This is achieved by constructing a test facility for laboratory experiments on real-time damage sensing. This test facility makes use of a methodology that has been formulated for fatigue crack model parameter estimation and significantly improves the quality of predictions of remaining life. Specifically, the thesis focuses on development of an on-line fatigue crack damage sensing and life prediction system that is built upon the disciplines of Systems Sciences and Mechanics of Materials. A major part of the research effort has been expended to design and fabricate a test apparatus which allows: (i) measurement and recording of statistical data for fatigue crack growth in metallic materials via different sensing techniques; and (ii) identification of stochastic model parameters for prediction of fatigue crack damage. To this end, this thesis describes the test apparatus and the associated instrumentation based on four different sensing techniques, namely, traveling optical microscopy, ultrasonic flaw detection, Alternating Current Potential Drop (ACPD), and fiber-optic extensometry-based compliance, for crack length measurements.
Effects of knee and ankle muscle fatigue on postural control in the unipedal stance.
Bizid, Riadh; Margnes, Eric; François, Yrieix; Jully, Jean Louis; Gonzalez, Gerard; Dupui, Philippe; Paillard, Thierry
2009-06-01
The aim of this study was to compare the effects of acute muscle fatigue of the ankle and knee musculature on postural control by immediate measures after performing fatiguing tasks (POST condition). One group of subjects (n = 8) performed a fatiguing task by voluntary contractions of the triceps surae (group TRI) and the other (n = 9) performed a fatiguing task by voluntary contractions of the quadriceps femoris (group QUA). Each muscle group was exercised until the loss of maximal voluntary contraction torque reached 50% (isokinetic dynamometer). Posture was assessed by measuring the centre of foot pressure (COP) with a force platform during a test of unipedal quiet standing posture with eyes closed. Initially (in PRE condition), the mean COP velocity was not significantly different between group TRI and group QUA. In POST condition, the mean COP velocity increased more in group QUA than in group TRI. The postural control was more impaired by knee muscle fatigue than by ankle muscle fatigue.
Microtexture Analysis and Modeling of Ambient Fatigue and Creep-Fatigue Damages in Ti-6Al-4V Alloy
NASA Astrophysics Data System (ADS)
Kumar, Jalaj; Singh, A. K.; Raman, S. Ganesh Sundara; Kumar, Vikas
2017-02-01
In the present investigation, microtexture analysis using electron back-scattered diffraction technique has been performed to study fatigue- and creep-fatigue damages and associated deformation structures in Ti-6Al-4V alloy. Special emphasis has been given to low-angle grain boundary configuration and its possible application as a damage indicator. Damage is mostly present in the form of voids as investigated through scanning electron microscopy. Stored deformation energies have been evaluated for the strain-controlled fatigue-, the stress-controlled fatigue-, and the creep-fatigue-tested samples. Stored deformation energies have also been analyzed vis-à-vis total damage energies to quantify the contribution of damages to various samples. A relation between the stored deformation energy and the applied strain amplitude has been proposed in this study.
Effect of Pre-Strain on the Fatigue Behavior of Extruded AZ31 Alloys
NASA Astrophysics Data System (ADS)
Wu, Yanjun
2017-09-01
An attempt is made to rationalize the effect of pre-strain history on fatigue behaviors of AZ31 magnesium alloy. Axial fatigue tests were conducted in the extruded and pre-compressioned AZ31 alloy under low cycle total strain control fatigue conditions. The pre-strain process influences the plastic deformation mechanism activated during fatigue deformation, especially during tensile loading, by enhancing the activity of detwinning mechanism. The low-cycle fatigue lifetime of extruded AZ31 alloy can be enhanced by the pre-compression process. And the hysteresis energy was successfully used to predict the low-cycle fatigue lifetime.
Bidirectional Relationships Between Fatigue and Everyday Experiences in Persons Living With HIV.
Cook, Paul F; Hartson, Kimberly R; Schmiege, Sarah J; Jankowski, Catherine; Starr, Whitney; Meek, Paula
2016-06-01
Fatigue symptoms are very common among persons living with HIV (PLWH). Fatigue is related to functional and psychological problems and to treatment nonadherence. Using secondary data from ecological momentary assessment, we examined fatigue as a predictor of PLWH everyday experiences. In bidirectional analyses based on the shape shifters model, we also examined these experiences as predictors of fatigue. Data were examined from 67 PLWH who completed daily surveys on a handheld computer. Brief validated scales were used to assess participants' control beliefs, mood, stress, coping, social support, experience of stigma, and motivation. At the beginning and end of the study, fatigue was measured with two CES-D items that have been used in past HIV symptom research. Multilevel models and logistic regression were used to test reciprocal predictive relationships between variables. Moderate to severe fatigue affected 45% of PLWH in the study. Initial fatigue predicted PLWH subsequent overall level of control beliefs, mood, stress, coping, and social support, all p < .05. These state variables remained relatively constant over time, regardless of participants' initial fatigue. In tests for reciprocal relationships with 33 PLWH, average daily stress, OR = 4.74, and stigma, OR = 4.86, also predicted later fatigue. Fatigue predicted several daily survey variables including stress and social support. Stress and support in turn predicted fatigue at a later time, suggesting a self-perpetuating cycle but also a possible avenue for intervention. Future studies should examine daily variation in fatigue among PLWH and its relation to other everyday experiences and behaviors. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Wang, Hong; Lee, Sung-Min; Wang, James L.; Lin, Hua-Tay
2014-12-01
Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 108 cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and the fatigue index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications, such as piezoelectric fuel injectors in heavy-duty diesel engines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hong; Lee, Sung Min; Wang, James L.
Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 10^8 cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and themore » fatigue index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications such as piezoelectric fuel injectors in heavy-duty diesel engines.« less
Wang, Hong; Lee, Sung Min; Wang, James L.; ...
2014-12-19
Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 10^8 cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and themore » fatigue index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications such as piezoelectric fuel injectors in heavy-duty diesel engines.« less
Taltirelin alleviates fatigue-like behavior in mouse models of cancer-related fatigue.
Dougherty, John P; Wolff, Brian S; Cullen, Mary J; Saligan, Leorey N; Gershengorn, Marvin C
2017-10-01
Fatigue affects most cancer patients and has numerous potential causes, including cancer itself and cancer treatment. Cancer-related fatigue (CRF) is not relieved by rest, can decrease quality of life, and has no FDA-approved therapy. Thyrotropin-releasing hormone (TRH) has been proposed as a potential novel treatment for CRF, but its efficacy against CRF remains largely untested. Thus, we tested the TRH analog, taltirelin (TAL), in mouse models of CRF. To model fatigue, we used a mouse model of chemotherapy, a mouse model of radiation therapy, and mice bearing colon 26 carcinoma tumors. We used the treadmill fatigue test to assess fatigue-like behavior after treatment with TAL. Additionally, we used wild-type and TRH receptor knockout mice to determine which TRH receptor was necessary for the actions of TAL. Tumor-bearing mice displayed muscle wasting and all models caused fatigue-like behavior, with mice running a shorter distance in the treadmill fatigue test than controls. TAL reversed fatigue-like behavior in all three models and the mouse TRH 1 receptor was necessary for the effects of TAL. These data suggest that TAL may be useful in alleviating fatigue in all cancer patients and provide further support for evaluating TAL as a potential therapy for CRF in humans. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Bartolotta, Paul A.
1991-01-01
Metal Matrix Composites (MMC) and Intermetallic Matrix Composites (IMC) were identified as potential material candidates for advanced aerospace applications. They are especially attractive for high temperature applications which require a low density material that maintains its structural integrity at elevated temperatures. High temperature fatigue resistance plays an important role in determining the structural integrity of the material. This study attempts to examine the relevance of test techniques, failure criterion, and life prediction as they pertain to an IMC material, specifically, unidirectional SiC fiber reinforced titanium aluminide. A series of strain and load controlled fatigue tests were conducted on unidirectional SiC/Ti-24Al-11Nb composite at 425 and 815 C. Several damage mechanism regimes were identified by using a strain-based representation of the data, Talreja's fatigue life diagram concept. Results of these tests were then used to address issues of test control modes, definition of failure, and testing techniques. Finally, a strain-based life prediction method was proposed for an IMC under tensile cyclic loadings at elevated temperatures.
Williamson, A M; Feyer, A M; Mattick, R P; Friswell, R; Finlay-Brown, S
2001-05-01
The effects of 28 h of sleep deprivation were compared with varying doses of alcohol up to 0.1% blood alcohol concentration (BAC) in the same subjects. The study was conducted in the laboratory. Twenty long-haul truck drivers and 19 people not employed as professional drivers acted as subjects. Tests were selected that were likely to be affected by fatigue, including simple reaction time, unstable tracking, dual task, Mackworth clock vigilance test, symbol digit coding, visual search, sequential spatial memory and logical reasoning. While performance effects were seen due to alcohol for all tests, sleep deprivation affected performance on most tests, but had no effect on performance on the visual search and logical reasoning tests. Some tests showed evidence of a circadian rhythm effect on performance, in particular, simple reaction time, dual task, Mackworth clock vigilance, and symbol digit coding, but only for response speed and not response accuracy. Drivers were slower but more accurate than controls on the symbol digit test, suggesting that they took a more conservative approach to performance of this test. This study demonstrated which tests are most sensitive to sleep deprivation and fatigue. The study therefore has established a set of tests that can be used in evaluations of fatigue and fatigue countermeasures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dennis, L.B.
1994-12-01
This research extends the existing knowledge of cross-ply metal matrix composites (MMC) to include fatigue behavior under strain-controlled fully reversed loading. This study investigated fatigue life, failure modes and damage mechanisms of the SCS-6/Ti-15-3, (O/9O)2s, MMC. The laminate was subjected to fully reversed fatigue at elevated temperature (427 deg C) at various strain levels. Stress, strain and modulus data were analyzed to characterize the macro-mechanical behavior of the composite. Microscopy and fractography were accomplished to identify and characterize the damage mechanisms at the microscopic level. Failure modes varied according to the maximum applied strain level showing either mixed mode (i.e.more » combination of both fiber and matrix dominated modes) or matrix dominated fatigue failures. As expected, higher strain loadings resulted in more ductility of the matrix at failure, evidenced by fracture surface features. For testing of the same composite laminate, the fatigue life under strain controlled mode slightly increased, compared to its load-controlled mode counterpart, using the effective strain range comparison basis. However, the respective fatigue life curves converged in the high cycle region, suggesting that the matrix dominated failure mode produces equivalent predicted fatigue lives for both control modes.« less
Efficacy of a footbath for post-partum fatigue in South Korea: A quasi-experimental study.
Choi, Eunsun; Song, Eunju
2017-04-01
The purpose of this study was to identify the effects of a footbath on post-partum fatigue. This study used a quasi-experimental design by using an unequivalent control group, pre-post-test design. The participants were divided into experimental and control groups. Fifty post-partum women who were admitted to an obstetrics and gynecology ward of a general hospital were the experimental group and 50 post-partum women who were admitted to an obstetrics and gynecology ward of a women's hospital were the control group. Two hospitals were providing similar postnatal care to their patients and they were located in the same city. The experimental group received a footbath along with postnatal care at the hospital, while the control group received only postnatal care from the hospital. Each group completed the Fatigue Continuum Form at a specified time. The general characteristics and pretest dependent variables were homogenous between the two groups. The hypothesis was supported post-test as the Fatigue Continuum Form scores differed significantly between the experimental and the control groups. This study showed that a footbath helps to decrease fatigue among post-partum women. In addition, it is a good preventative strategy for post-partum women who should initiate it in the early post-partum period. © 2016 Japan Academy of Nursing Science.
NASA Astrophysics Data System (ADS)
Takahashi, Kyouhei; Ogawa, Takeshi
Ultrasonic fatigue tests have been performed in austenitic stainless steel, SUS316NG, in order to investigate giga-cycle fatigue strength of pre-strained materials, i.e. 5, 10 and 20% tensile pre-strains and -20% compressive pre-strain. The pre-strains were applied before specimen machining. The austenitic stainless steels are known to exhibit remarkable self-heating during the fatigue experiment. Therefore, heat radiation method was established by setting fatigue specimens in a low temperature chamber at about -100°C. The self-heating was controlled by intermittent loading condition, which enabled us to maintain the test section of the specimens at about room temperature. The results revealed that the fatigue strength increased with increasing pre-strain levels. Fish-eye fracture was observed for -20% pre-strained specimen fractured at 4.11×107 cycles, while the other specimens exhibited ordinary fatigue fracture surface originated from stage I facet on the specimen surface. The increase in fatigue limit was predicted by Vickers hardness, HV, which depended on the size of indented region. The prediction was successful using HV values obtained by the size of the indented region similar to those of the stage I facets.
Holtzer, Roee; Foley, Frederick; D'Orio, Vanessa; Spat, Jessica; Shuman, Melissa; Wang, Cuiling
2013-10-01
Compromised learning and cognitive fatigue are critical clinical features in multiple sclerosis. This study was designed to determine the effect of repeated exposures within and across study visits on performance measures of learning and cognitive fatigue in relapsing-remitting multiple sclerosis (RRMS). Thirty patients with RRMS and 30 controls were recruited. Using a burst measurement design (i.e. repeated assessments within and across study visits) the oral version of the Symbol Digit Modalities Test (SDMT) was administered three times during the baseline and two consecutive monthly follow-up visits for a total of nine test administrations. Learning was assessed within and across study visits whereas cognitive fatigue was assessed during the course of each test administration that was divided into three 30-second intervals. Linear mixed-effect models revealed compromised learning within (95% CI: 2.6355 to 3.9867) and across (95% CI: 1.3250 to 3.1861) visits and worse cognitive fatigue (95% CI: -2.1761 to -0.1720) in patients with RRMS compared with controls. Among patients with RRMS, worse self-rated cognitive dysfunction predicted poor learning within (95% CI: -0.1112 to -0.0020) and across (95% CI: -0.0724 to -0.0106) visits. Burst design is optimal to study learning and cognitive fatigue. This methodology, using the SDMT or other time-efficient tests as outcome measures, can be successfully implemented in longitudinal studies and clinical trials.
Progress Report on Long Hold Time Creep Fatigue of Alloy 617 at 850°C
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carroll, Laura Jill
Alloy 617 is the leading candidate material for an intermediate heat exchanger for the very high temperature reactor. To evaluate the behavior of this material in the expected service conditions, strain-controlled cyclic tests that include long hold times up to 240 minutes at maximum tensile strain were conducted at 850°C. In terms of the total number of cycles to failure, the fatigue resistance decreased when a hold time was added at peak tensile strain. Increases in the tensile hold duration degraded the creep-fatigue resistance, at least to the investigated strain controlled hold time of up to 60 minutes at themore » 0.3% strain range and 240 minutes at the 1.0% strain range. The creep-fatigue deformation mode is considered relative to the lack of saturation, or continually decreasing number of cycles to failure with increasing hold times. Additionally, preliminary values from the 850°C creep-fatigue data are calculated for the creep-fatigue damage diagram and have higher values of creep damage than those from tests at 950°C.« less
Stubberud, Jan; Edvardsen, Espen; Schanke, Anne-Kristine; Lerdal, Anners; Kjeverud, Anita; Schillinger, Andreas; Løvstad, Marianne
2017-07-05
The purpose of this pilot study was to describe and explore a group-based multifaceted intervention for patients with fatigue after acquired brain injury (ABI). We hypothesised that post-intervention changes would result in reduced fatigue, in addition to improved emotional health, sleep and attentional control. Eight subjects with traumatic brain injury (n = 3) and cerebrovascular insults (n = 5) were included. Inclusion was based upon the presence of fatigue complaints. The participants received 36 hours of intervention. Changes related to fatigue, emotional health and sleep was assessed with self-rating measures. Additionally, a neuropsychological test (Conners' Continuous Performance Test II) was included as a measure of attentional control. All subjects were assessed at baseline, post-intervention, and at 3 and 9 months follow-up. Findings indicated reduced fatigue levels (post-intervention and 3 months follow-up), anxiety (9 months follow-up), and daytime sleepiness (3 and 9 months follow-up). Pilot results suggest that multifaceted group-based interventions may have the potential to alleviate symptoms of fatigue, anxiety and sleepiness after ABI. At an individual level, a low load of psychological distress, insomnia symptoms, dysexecutive symptoms, in addition to a strong sense of self-efficacy, may be central in order to reduce levels of fatigue.
Damage development in titanium metal matrix composites subjected to cyclic loading
NASA Technical Reports Server (NTRS)
Johnson, W. S.
1992-01-01
Several layups of SCS-6/Ti-15-3 composites were investigated. Fatigue tests were conducted and analyzed for both notched and unnotched specimens at room temperature and elevated temperatures. Thermo-mechanical fatigue results were analyzed. Test results indicated that the stress in the 0 degree fibers is the controlling factor in fatigue life. The static and fatigue strength of these materials is shown to be strongly dependent on the level of residual stresses and the fiber/matrix interfacial strength. Fatigue tests of notched specimens showed that cracks can initiate and grow many fiber spacings in the matrix materials without breaking fibers. Fiber bridging models were applied to characterize the crack growth behavior. The matrix cracks are shown to significantly reduce the residual strength of notched composites. The notch strength of these composites was accurately predicted using a micromechanics based methodology.
Damage development in titanium metal-matrix composites subjected to cyclic loading
NASA Technical Reports Server (NTRS)
Johnson, W. S.
1993-01-01
Several layups of SCS-6/Ti-15-3 composites were investigated. Fatigue tests were conducted and analyzed for both notched and unnotched specimens at room temperature and elevated temperatures. Thermo-mechanical fatigue results were analyzed. Test results indicated that the stress in the 0 degree fibers is the controlling factor in fatigue life. The static and fatigue strength of these materials is shown to be strongly dependent on the level of residual stresses and the fiber/matrix interfacial strength. Fatigue tests of notched specimens showed that cracks can initiate and grow many fiber spacings in the matrix materials without breaking fibers. Fiber bridging models were applied to characterize the crack growth behavior. The matrix cracks are shown to significantly reduce the residual strength of notched composites. The notch strength of these composites was accurately predicted using a micromechanics based methodology.
Montgomery, Guy H; Kangas, Maria; David, Daniel; Hallquist, Michael N; Green, Sheryl; Bovbjerg, Dana H; Schnur, Julie B
2009-05-01
The study purpose was to test the effectiveness of a psychological intervention combining cognitive-behavioral therapy and hypnosis (CBTH) to treat radiotherapy-related fatigue. Women (n = 42) scheduled for breast cancer radiotherapy were randomly assigned to receive standard medical care (SMC) (n = 20) or a CBTH intervention (n = 22) in addition to SMC. Participants assigned to receive CBTH met individually with a clinical psychologist. CBTH participants received training in hypnosis and CBT. Participants assigned to the SMC control condition did not meet with a study psychologist. Fatigue was measured on a weekly basis by using the fatigue subscale of the Functional Assessment of Chronic Illness Therapy (FACIT) and daily using visual analogue scales. Multilevel modeling indicated that for weekly FACIT fatigue data, there was a significant effect of the CBTH intervention on the rate of change in fatigue (p < .05), such that on average, CBTH participants' fatigue did not increase over the course of treatment, whereas control group participants' fatigue increased linearly. Daily data corroborated the analyses of weekly data. The results suggest that CBTH is an effective means for controlling and potentially preventing fatigue in breast cancer radiotherapy patients.
Closed-Loop Control for Sonic Fatigue Testing Systems
NASA Technical Reports Server (NTRS)
Rizzi, Stephen A.; Bossaert, Guido
2001-01-01
This article documents recent improvements to the acoustic control system of the Thermal Acoustic Fatigue Apparatus (TAFA), a progressive wave tube test facility at the NASA Langley Research Center, Hampton, VA. A brief summary of past acoustic performance is first given to serve as a basis of comparison with the new performance data using a multiple-input, closed-loop, narrow-band controller. Performance data in the form of test section acoustic power spectral densities and coherence are presented for a variety of input spectra including uniform, band-limited random and an expendable launch vehicle payload bay environment.
Stiffness reductions during tensile fatigue testing of graphite/epoxy angle-ply laminates
NASA Technical Reports Server (NTRS)
Odom, E. M.; Adams, D. F.
1982-01-01
Tensile fatigue data was generated under carefully controlled test conditions. A computerized data acquisition system was used to permit the measurement of dynamic modulus without interrupting the fatigue cycling. Two different 8-ply laminate configurations, viz, + or - 45 (2s) and + or - 67.5 (2s), of a T300/5208 graphite/epoxy composite were tested. The + or - 45 (2s) laminate did exhibit some modulus decay, although there was no well-defined correlation with applied stress level or number of cycles. The + or - 67.5 (2s) laminate did not exhibit any measurable modulus decay. Secondary effects observed included a small but distinct difference between modulus as measured statically and dynamically, a slight recovery of the modulus decay after a test interruption, and a significant viscoelastic (creep) response of the + or - 45 (2s) laminate during fatigue testing.
Effect of lubricant extreme-pressure additives on surface fatigue life of AISI 9310 spur gears
NASA Technical Reports Server (NTRS)
Scibbe, H. W.; Townsend, D. P.; Aron, P. R.
1984-01-01
Surface fatigue tests were conducted with AISI 9310 spur gears using a formulated synthetic tetraester oil (conforming to MIL-L-23699 specifications) as the lubricant containing either sulfur or phosphorus as the EP additive. Four groups of gears were tested. One group of gears tested without an additive in the lubricant acted as the reference oil. In the other three groups either a 0.1 wt % sulfur or phosphorus additive was added to the tetraester oil to enhance gear surface fatigue life. Test conditions included a gear temperature of 334 K (160 F), a maximum Hertz stress of 1.71 GPa (248 000 psi), and a speed of 10,000 rpm. The gears tested with a 0.1 wt % phosphorus additive showed pitting fatigue life 2.6 times the life of gears tested with the reference tetraester based oil. Although fatigue lives of two groups of gears tested with the sulfur additive in the oil showed improvement over the control group gear life, the results, unlike those obtained with the phosphorus oil, were not considered to be statistically significant.
Amaral, Marina; Rocha, Regina FV; Melo, Renata Marques; Pereira, Gabriel KR; Zhang, Yu; Valandro, Luiz Felipe; Bottino, Marco Antonio
2017-01-01
Objectives To determine the fatigue limits of three-unit monolithic zirconia FDPs before and after grinding of the gingival areas of connectors with diamond burs. Material and Methods FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue limits and standard deviations were obtained using a staircase fatigue method (n = 20, 100,000 loading cycles/5 Hz). The initial test load was 70% of the mean load-to-fracture (n = 3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student’s T-test (α ≤ 0.05). Results Both the control and ground groups exhibited similar values of load-to-fracture and fatigue limits. Neither the surface treatments nor ageing affected the surface roughness of the specimens. Conclusions The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue limit of the three-unit monolithic zirconia FDP. PMID:28494273
Load-bearing capacity of all-ceramic posterior inlay-retained fixed dental prostheses.
Puschmann, Djamila; Wolfart, Stefan; Ludwig, Klaus; Kern, Matthias
2009-06-01
The purpose of this in vitro study was to compare the quasi-static load-bearing capacity of all-ceramic resin-bonded three-unit inlay-retained fixed dental prostheses (IRFDPs) made from computer-aided design/computer-aided manufacturing (CAD/CAM)-manufactured yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) frameworks with two different connector dimensions, with and without fatigue loading. Twelve IRFDPs each were made with connector dimensions 3 x 3 mm(2) (width x height) (control group) and 3 x 2 mm(2) (test group). Inlay-retained fixed dental prostheses were adhesively cemented on identical metal-models using composite resin cement. Subgroups of six specimens each were fatigued with maximal 1,200,000 loading cycles in a chewing simulator with a weight load of 25 kg and a load frequency of 1.5 Hz. The load-bearing capacity was tested in a universal testing machine for IRFDPs without fatigue loading and for IRFDPs that had not already fractured during fatigue loading. During fatigue testing one IRFDP (17%) of the test group failed. Under both loading conditions, IRFDPs of the control group exhibited statistically significantly higher load-bearing capacities than the test group. Fatigue loading reduced the load-bearing capacity in both groups. Considering the maximum chewing forces in the molar region, it seems possible to use zirconia ceramic as a core material for IRFDPs with a minimum connector dimension of 9 mm(2). A further reduction of the connector dimensions to 6 mm(2) results in a significant reduction of the load-bearing capacity.
Stroke-Related Changes in Neuromuscular Fatigue of the Hip Flexors and Functional Implications
Hyngstrom, Allison S.; Onushko, Tanya; Heitz, Robert P.; Rutkowski, Anthony; Hunter, Sandra K.; Schmit, Brian D.
2014-01-01
Objective To compare stroke-related changes in hip-flexor neuromuscular fatigue of the paretic leg during a sustained, isometric sub-maximal contraction with the non-paretic leg and controls, and correlate fatigue with clinical measures of function. Design Hip torques were measured during a fatiguing hip-flexion contraction at 20% of the hip flexion maximal voluntary contraction (MVC) in the paretic and non-paretic legs of 13 people with chronic stroke and 10 age-matched controls. In addition, participants with stroke performed a fatiguing contraction of the paretic leg at the absolute torque equivalent to 20% MVC of the non-paretic leg and were tested for self-selected walking speed (Ten-Meter Walk Test) and balance (Berg). Results When matching the non-paretic target torque, the paretic hip flexors had a shorter time to task failure compared with the non-paretic leg and controls (p<0.05). Time to failure of the paretic leg was inversely correlated with the reduction of hip flexion MVC torque. Self-selected walking speed was correlated with declines in torque and steadiness. Berg-Balance scores were inversely correlated with the force fluctuation amplitude. Conclusions Fatigue and precision of contraction are correlated with walking function and balance post stroke. PMID:22157434
Zenouzi, Roman; von der Gablentz, Janina; Heldmann, Marcus; Göttlich, Martin; Weiler-Normann, Christina; Sebode, Marcial; Ehlken, Hanno; Hartl, Johannes; Fellbrich, Anja; Siemonsen, Susanne; Schramm, Christoph; Münte, Thomas F; Lohse, Ansgar W
2018-01-01
In primary biliary cholangitis (PBC) fatigue is a major clinical challenge of unknown etiology. By demonstrating that fatigue in PBC is associated with an impaired cognitive performance, previous studies have pointed out the possibility of brain abnormalities underlying fatigue in PBC. Whether structural brain changes are present in PBC patients with fatigue, however, is unclear. To evaluate the role of structural brain abnormalities in PBC patients severely affected from fatigue we, therefore, performed a case-control cerebral magnetic resonance imaging (cMRI) study and correlated changes of white and grey brain matter with the cognitive and attention performance. 20 female patients with PBC and 20 female age-matched controls were examined in this study. The assessment of fatigue, psychological symptoms, cognitive and attention performance included clinical questionnaires, established cognition tests and a computerized test battery of attention performance. T1-weighted cMRI and diffusion tensor imaging (DTI) scans were acquired with a 3 Tesla scanner. Structural brain alterations were investigated with voxel-based morphometry (VBM) and DTI analyses. Results were correlated to the cognitive and attention performance. Compared to healthy controls, PBC patients had significantly higher levels of fatigue and associated psychological symptoms. Except for an impairment of verbal fluency, no cognitive or attention deficits were found in the PBC cohort. The VBM and DTI analyses revealed neither major structural brain abnormalities in the PBC cohort nor correlations with the cognitive and attention performance. Despite the high burden of fatigue and selected cognitive deficits, the attention performance of PBC patients appears to be comparable to healthy people. As structural brain alterations do not seem to be present in PBC patients with fatigue, fatigue in PBC must be regarded as purely functional. Future studies should evaluate, whether functional brain changes underlie fatigue in PBC.
Clinical, laboratory, and neuroimaging characteristics of fatigue in HIV-infected individuals.
Schifitto, Giovanni; Deng, Lijuan; Yeh, Tzu-Min; Evans, Scott R; Ernst, Thomas; Zhong, Jianhui; Clifford, David
2011-02-01
Fatigue is among the most common symptoms reported by HIV-infected individuals. Previous reports suggest that the prevalence of fatigue varies by disease status with rates close to 80% in patients with AIDS. However, most studies have not been conducted in the setting of a controlled trial and have not assessed the association of fatigue with cellular markers of brain activity. Data for this study were derived from baseline and longitudinal evaluations in ACTG A5090, a randomized, double-blind, placebo-controlled trial of the Selegiline Transdermal System for the treatment of HIV-associated cognitive impairment. Fatigue was assessed using the Fatigue Severity Scale with scores of >4 considered "fatigued". Participants in a substudy underwent brain magnetic resonance spectroscopy (MRS) imaging, an in vivo method for assessing brain metabolites associated with neuronal and glia activity. Differences between fatigued and non-fatigued participants were evaluated with respect to demographics and clinical characteristics, plasma and CSF HIV-1 RNA concentration, CD4 counts, and brain metabolites. One hundred and twenty-eight participants were enrolled (88% male, median age = 45 years) and 82 participants (64%, 95% confidence interval 55%, 72%) were fatigued at baseline. MRS was conducted in 62 of the 128 participants. Fatigued participants were significantly younger (p = 0.011), had lower Karnofsky scores (p = 0.032), and had higher levels of depressive symptoms on the Center for Epidemiologic Studies Depression (CES-D) scale (p < 0.001) than non-fatigued participants. Statistically significant differences between fatigued and non-fatigued groups were not detected for plasma and CSF HIV-1RNA concentration, CD4 counts, or on neuropsychological tests. MRS revealed significantly lower levels of the cellular energy marker total creatine (p = 0.002) in the basal ganglia of fatigued participants. Statistically significant differences in other brain metabolites were not detected. Longitudinal data showed that fatigue persisted and worse fatigue at baseline was predictor of future fatigue. Among the cognitive tests, baseline Stroop score was associated with future fatigue. Fatigue was present in 64% of A5090 study participants and persisted during the 24 weeks of follow-up. Fatigue was associated with worse functional performance and depressive mood. Lower cellular energy levels in the basal ganglia, as measured by MRS total creatine concentration, suggest energy dysmetabolism in this brain region. This observation, taken together with the association between fatigue and neuropsychological tests of frontal lobe performance is consistent with the hypothesis of a striatal-cortical circuitry involvement in the symptoms of fatigue.
The relationship between cell phone use and management of driver fatigue: It's complicated.
Saxby, Dyani Juanita; Matthews, Gerald; Neubauer, Catherine
2017-06-01
Voice communication may enhance performance during monotonous, potentially fatiguing driving conditions (Atchley & Chan, 2011); however, it is unclear whether safety benefits of conversation are outweighed by costs. The present study tested whether personalized conversations intended to simulate hands-free cell phone conversation may counter objective and subjective fatigue effects elicited by vehicle automation. A passive fatigue state (Desmond & Hancock, 2001), characterized by disengagement from the task, was induced using full vehicle automation prior to drivers resuming full control over the driving simulator. A conversation was initiated shortly after reversion to manual control. During the conversation an emergency event occurred. The fatigue manipulation produced greater task disengagement and slower response to the emergency event, relative to a control condition. Conversation did not mitigate passive fatigue effects; rather, it added worry about matters unrelated to the driving task. Conversation moderately improved vehicle control, as measured by SDLP, but it failed to counter fatigue-induced slowing of braking in response to an emergency event. Finally, conversation appeared to have a hidden danger in that it reduced drivers' insights into performance impairments when in a state of passive fatigue. Automation induced passive fatigue, indicated by loss of task engagement; yet, simulated cell phone conversation did not counter the subjective automation-induced fatigue. Conversation also failed to counter objective loss of performance (slower braking speed) resulting from automation. Cell phone conversation in passive fatigue states may impair drivers' awareness of their performance deficits. Practical applications: Results suggest that conversation, even using a hands-free device, may not be a safe way to reduce fatigue and increase alertness during transitions from automated to manual vehicle control. Copyright © 2017 Elsevier Ltd and National Safety Council. All rights reserved.
Nanosecond pulsed laser micromachining for experimental fatigue life study of Ti-3Al-2.5V tubes
NASA Astrophysics Data System (ADS)
Lin, Yaomin; Gupta, Mool C.; Taylor, Robert E.; Lei, Charles; Stone, William; Spidel, Tom; Yu, Michael; Williams, Reanne
2009-01-01
Defects on external surface of in-service hydraulic tubes can reduce total life cycles for operation. Evaluation of fatigue life of the tubes with damage is thus critical for safety reasons. A methodology of generating defects in the Ti-3Al-2.5V tube—a widely used pipeline in hydraulic systems of aircrafts—using nanosecond pulsed laser for experimental fatigue life study is described in this paper. Straight tubes of five different sizes were laser micromachined to generate notches of given length and depths on the outside surface. Approaches were developed to precisely control the notch dimensions. The laser-notched tubes were tested with cyclic internal impulse pressure and fatigue life was measured. The laser notches and fatigue cracks were characterized after the test. It is concluded that laser micromachining generated consistent notches, and the influence of notch depth on fatigue life of the tube is significant. Based on the experimental test results, the relationship between the fatigue life of the Ti-3Al-2.5V tube and the notch depth was revealed. The research demonstrated that laser micromachining is applicable for experimental fatigue life study of titanium tubes. The presented test data are useful for estimating the damage limits of the titanium tubes in service environment and for further theoretical studies.
On massive carbide precipitation during high temperature low cycle fatigue in alloy 800H
NASA Technical Reports Server (NTRS)
Sankararao, K. Bhanu; Schuster, H.; Halford, G. R.
1994-01-01
The effect of strain rate on massive precipitation and the mechanism for the occurrence of massive precipitation of M23C6 in alloy 800H is investigated during elevated temperature low cycle fatigue testing. It was observed that large M23C6 platelets were in the vicinity of grain and incoherent twin boundaries. The strain controlled fatigue testing at higher strain rates that promoted cyclic hardening enabled massive precipitation to occur more easily.
Clinical, laboratory, and neuroimaging characteristics of fatigue in HIV-infected individuals
Schifitto, Giovanni; Deng, Lijuan; Yeh, Tzu-min; Evans, Scott R.; Ernst, Thomas; Zhong, Jianhui; Clifford, David
2011-01-01
Fatigue is among the most common symptoms reported by HIV-infected individuals. Previous reports suggest that the prevalence of fatigue varies by disease status with rates close to 80% in patients with AIDS. However, most studies have not been conducted in the setting of a controlled trial and have not assessed the association of fatigue with cellular markers of brain activity. Data for this study were derived from baseline and longitudinal evaluations in ACTG A5090, a randomized, double-blind, placebo-controlled trial of the Selegiline Transdermal System for the treatment of HIV-associated cognitive impairment. Fatigue was assessed using the Fatigue Severity Scale with scores of >4 considered “fatigued”. Participants in a substudy underwent brain magnetic resonance spectroscopy (MRS) imaging, an in vivo method for assessing brain metabolites associated with neuronal and glia activity. Differences between fatigued and non-fatigued participants were evaluated with respect to demographics and clinical characteristics, plasma and CSF HIV-1 RNA concentration, CD4 counts, and brain metabolites. One hundred and twenty-eight participants were enrolled (88% male, median age=45 years) and 82 participants (64%, 95% confidence interval 55%, 72%) were fatigued at baseline. MRS was conducted in 62 of the 128 participants. Fatigued participants were significantly younger (p=0.011), had lower Karnofsky scores (p=0.032), and had higher levels of depressive symptoms on the Center for Epidemiologic Studies Depression (CES-D) scale (p<0.001) than non-fatigued participants. Statistically significant differences between fatigued and non-fatigued groups were not detected for plasma and CSF HIV-1RNA concentration, CD4 counts, or on neuropsychological tests. MRS revealed significantly lower levels of the cellular energy marker total creatine (p=0.002) in the basal ganglia of fatigued participants. Statistically significant differences in other brain metabolites were not detected. Longitudinal data showed that fatigue persisted and worse fatigue at baseline was predictor of future fatigue. Among the cognitive tests, baseline Stroop score was associated with future fatigue. Fatigue was present in 64% of A5090 study participants and persisted during the 24 weeks of follow-up. Fatigue was associated with worse functional performance and depressive mood. Lower cellular energy levels in the basal ganglia, as measured by MRS total creatine concentration, suggest energy dysmetabolism in this brain region. This observation, taken together with the association between fatigue and neuropsychological tests of frontal lobe performance is consistent with the hypothesis of a striatal–cortical circuitry involvement in the symptoms of fatigue. PMID:21181521
Fogt, Donovan L; Kalns, John E; Michael, Darren J
2010-12-01
Fatigue is known to impair cognitive performance, but it remains unclear whether concurrent common stressors affect cognitive performance similarly. We used the Stroop Color-Word Conflict Test to assess cognitive performance over 24 hours for four groups: control, sleep-deprived (SD), SD + energy deficit, and SD + energy deficit + fluid restricted. Fatigue levels were quantified using the Profile of Mood States (POMS) survey. Linear mixed-effects (LME) models allowed for testing of group-specific differences in cognitive performance while accounting for subject-level variation. Starting fatigue levels were similar among all groups, while 24-hour fatigue levels differed significantly. For each cognitive performance test, results were modeled separately. The simplest LME model contained a significant fixed-effects term for slope and intercept. Moreover, the simplest LME model used a single slope coefficient to fit data from all four groups, suggesting that loss in cognitive performance over a 24-hour duty cycle with respect to fatigue level is similar regardless of the cause.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hong, E-mail: wangh@ornl.gov; Lee, Sung-Min; Wang, James L.
Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 10{sup 8} cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and the fatiguemore » index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications, such as piezoelectric fuel injectors in heavy-duty diesel engines.« less
Verification of Cold Working and Interference Levels at Fastener Holes
2009-02-01
of the Residual Stress Field on the Fatigue Coupons ........................................ 32 3.3.3 Fractography of Fatigue Test Coupons...predictions to fatigue experiment results (none of the literature we reviewed described fractography of cracks propagating through residual stress...ensures continued safety, readiness, and controlled maintenance costs. These methods augment and enhance traditional safe-life and damage tolerance
Ye, Jia; Gao, Yong
2012-01-01
Rotary instruments made of a new nickel-titanium (NiTi) alloy (M-Wire) have shown improved cyclic fatigue resistance and mechanical properties compared with those made of conventional superelastic NiTi wires. The objective of this study was to characterize microstructural changes of M-Wire throughout the cyclic fatigue process under controlled strain amplitude. The average fatigue life was calculated from 30 M-Wire samples that were subjected to a strain-controlled (≈ 4%) rotating bend fatigue test at room temperature and rotational speed of 300 rpm. Microstructural evolution of M-Wire has been investigated by different metallurgical characterization techniques, including differential scanning calorimetry, Vickers microhardness, and transmission electron microscopy at 4 different stages (as-received state, 30%, 60%, and 90% of average fatigue life). During rotating bend fatigue test, no statistically significant difference (P > .05) was found on austenite finish temperatures between as-received M-Wire and fatigued samples. However, significant differences (P < .05) were observed on Vickers microhardness for samples with 60% and 90% fatigue life compared with as-received and 30% fatigue life. Coincidentally, substantial growth of martensite grains and martensite twins was observed in microstructure under transmission electron microscopy after 60% fatigue life. The results of the present study suggested that endodontic instruments manufactured with M-Wire are expected to have higher strength and wear resistance than similar instruments made of conventional superelastic NiTi wires because of its unique nano-crystalline martensitic microstructure. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Stokes, M J; Colter, C; Klestov, A; Cooper, R G
1993-08-01
Paraspinal muscle fatigue mechanisms were compared in 14 primary fibromyalgia patients and 14 age and sex matched normal subjects using a standardized 60-s isometric endurance test of the paraspinal muscles, during which surface integrated electromyographic (IEMG) activity was recorded. Fatigue-induced IEMG increases were similar for both groups during the initial 40 s (up to 112 +/- 20% and 111 +/- 6% of initial values in patients and normal subjects respectively). Thereafter, IEMG fell significantly in patients (P < 0.05) but only slightly in controls, so that at 58 s IEMG was 102 +/- 13% in patients and 109 +/- 12% in controls. If patients were divided according to body mass index (BMI, range 19-25 in controls) those with a BMI < 26 (n = 5) showed IEMG changes similar to those of control subjects throughout the test, while obese patients with BMI > 26 (n = 9) showed greater IEMG declines after 40 s than either normal subjects or in the fibromyalgia group as a whole. Paraspinal muscle fatigue mechanisms appear normal in primary fibromyalgia patients. Isometric force maintenance in overweight patients, despite IEMG declines, illustrates the action of intrinsic fatigue resistance mechanisms which were presumably utilized to a greater extent in these patients to cope with the extra load.
Low-Cycle Fatigue Behavior of Die-Cast Mg Alloy AZ91
NASA Astrophysics Data System (ADS)
Rettberg, Luke; Anderson, Warwick; Jones, J. Wayne
An investigation has been conducted on the influence of microstructure and artificial aging response (T6) on the low-cycle fatigue behavior of super vacuum die-cast (SVDC) AZ91. Fatigue lifetimes were determined from total strain-controlled fatigue tests for strain amplitudes of 0.2%, 0.4% and 0.6%, under fully reversed loading at a frequency of 5 Hz. Cyclic stress-strain behavior was determined using incremental step test (IST) methods. Two locations in a prototype casting with different thicknesses and, therefore, solidification rates, microstructure and porosity, were examined. In general., at all total strain amplitudes fatigue life was unaffected by microstructure refinement and was attributed to significant levels of porosity. Cyclic softening and a subsequent increased cyclic hardening rate, compared to monotonic tests, were observed, independent of microstructure. These results, fractography and damage accumulation processes, determined from metallographic sectioning, are discussed.
Sarzi-Puttini, Piercarlo; Atzeni, Fabiola; Di Franco, Manuela; Lama, Nicola; Batticciotto, Alberto; Iannuccelli, Cristina; Dell'Acqua, Donata; de Portu, Simona; Riccieri, Valeria; Carrabba, Mario; Buskila, Dan; Doria, Andrea; Valesini, Guido
2008-02-01
To investigate the prevalence of antipolymer antibody (APA) in patients with fibromyalgia (FM) and to examine its association with FM severity symptoms. The study population consisted of 79 FM patients and 75 controls: 32 with psoriatic arthritis and 43 with rheumatoid arthritis APA levels were indirectly assayed using a commercial ELISA kit from Corgenix (Westmister, Colorado, USA). Optical density (OD) values were recorded on duplicates of each of the reference and patient samples. Among clinical variables we investigated pain, measured according to visual analog scales (VAS: 0-100), fatigue, stiffness, anxiety, depression, all measured by VAS (0-100), and health status measured by Fibromyalgia Impact Questionnaire (FIQ). Sixteen of the 79 FM patients (20.3%) and 12/78 controls (15.4%) were positive for APAs (P = 0.536). Following ROC analysis, area under curve (AUC) was 0.49 (95% CI: 0.40, 0.58). Focusing on FM patients, we observed a correlation between APA titre and pain (tau: - 0.221; P = 0.020) and fatigue (tau: - 0.205; P = 0.032) at univariate analysis. Binomial regression analysis, controlling for clinical and demographic variables, showed that pain (PPR: 0.923; P = 0.007) and fatigue (PPR: 0.948; P = 0.024) were significantly associated with APA test sensitivity. APA test exhibited a low sensitivity in FM patients and it did not distinguish this group of patients from the controls enrolled in this study. Interestingly, positive APA test prevalence increased with less severe pain or fatigue.
Determination of Failure Point of Asphalt-Mixture Fatigue-Test Results Using the Flow Number Method
NASA Astrophysics Data System (ADS)
Wulan, C. E. P.; Setyawan, A.; Pramesti, F. P.
2018-03-01
The failure point of the results of fatigue tests of asphalt mixtures performed in controlled stress mode is difficult to determine. However, several methods from empirical studies are available to solve this problem. The objectives of this study are to determine the fatigue failure point of the results of indirect tensile fatigue tests using the Flow Number Method and to determine the best Flow Number model for the asphalt mixtures tested. In order to achieve these goals, firstly the best asphalt mixture of three was selected based on their Marshall properties. Next, the Indirect Tensile Fatigue Test was performed on the chosen asphalt mixture. The stress-controlled fatigue tests were conducted at a temperature of 20°C and frequency of 10 Hz, with the application of three loads: 500, 600, and 700 kPa. The last step was the application of the Flow Number methods, namely the Three-Stages Model, FNest Model, Francken Model, and Stepwise Method, to the results of the fatigue tests to determine the failure point of the specimen. The chosen asphalt mixture is EVA (Ethyl Vinyl Acetate) polymer -modified asphalt mixture with 6.5% OBC (Optimum Bitumen Content). Furthermore, the result of this study shows that the failure points of the EVA-modified asphalt mixture under loads of 500, 600, and 700 kPa are 6621, 4841, and 611 for the Three-Stages Model; 4271, 3266, and 537 for the FNest Model; 3401, 2431, and 421 for the Francken Model, and 6901, 6841, and 1291 for the Stepwise Method, respectively. These different results show that the bigger the loading, the smaller the number of cycles to failure. However, the best FN results are shown by the Three-Stages Model and the Stepwise Method, which exhibit extreme increases after the constant development of accumulated strain.
The effects of mental fatigue on cricket-relevant performance among elite players.
Veness, Darren; Patterson, Stephen David; Jeffries, Owen; Waldron, Mark
2017-12-01
This study investigated the effects of a mentally fatiguing test on physical tasks among elite cricketers. In a cross-over design, 10 elite male cricket players from a professional club performed a cricket run-two test, a Batak Lite reaction time test and a Yo-Yo-Intermittent Recovery Level 1 (Yo-Yo-IR1) test, providing a rating of perceived exertion (RPE) after completing a 30-min Stroop test (mental fatigue condition) or 30-min control condition. Perceived fatigue was assessed before and after the two conditions and motivation was measured before testing. There were post-treatment differences in the perception of mental fatigue (P < 0.001; d = -7.82, 95% CIs = -9.05-6.66; most likely). Cricket run-two (P = 0.002; d = -0.51, 95% CIs = -0.72-0.30; very likely), Yo-Yo-IR1 distance (P = 0.023; d = 0.39, 95% CIs = 0.14-0.64; likely) and RPE (P = 0.001; d = -1.82, 95% CIs = -2.49-1.14; most likely) were negatively affected by mental fatigue. The Batak Lite test was not affected (P = 0.137), yet a moderate (d = 0.41, 95% CIs = -0.05-0.87) change was likely. Mental fatigue, induced by an app-based Stroop test, negatively affected cricket-relevant performance.
Jacobsen, Henrik B.; Aasvik, Julie K.; Borchgrevink, Petter C.; Landrø, Nils I.; Stiles, Tore C.
2016-01-01
Background: Subjective cognitive impairments are frequent, but poorly understood in patients with chronic fatigue. We hypothesized that maladaptive metacognitive beliefs at baseline were associated with baseline subjective cognitive impairments, that they predict subjective cognitive impairments at treatment termination, and that a reduction in maladaptive metacognitive beliefs was associated with less subjective cognitive impairments at treatment termination, independent of changes in fatigue, pain, insomnia, depression, and anxiety. Methods: In this non-controlled study, patients (n = 137) on sick leave due to chronic fatigue received a 3.5-week inpatient RTW rehabilitation program. Of these patients 69 (50.4%) was referred with a ICPC-2 diagnosis of chronic fatigue. Patients completed questionnaires about metacognitive beliefs, somatic complaints, psychological complaints, and cognitive impairments before and after treatment. To test the hypotheses we performed paired t-tests of change, as well as seven hierarchical linear regressions. Results: Results showed that baseline maladaptive metacognitive beliefs were significantly associated with subjective cognitive impairments at baseline, controlling for symptoms. Score on baseline metacognitive beliefs did not predict impairments post-treatment. Testing specific maladaptive beliefs, pre-treatment scores on cognitive confidence were associated with subjective cognitive impairments both pre and post-treatment, controlling for symptoms. Post-treatment metacognitive beliefs and post-treatment cognitive confidence were associated with post-treatment subjective cognitive impairments, controlling for pre-treatment impairments and pre-treatment metacognitive beliefs, as well as pre and post-scores on symptom measures. Conclusion: This study reports associations between maladaptive metacognitive beliefs and subjective cognitive impairments in patients with chronic fatigue. Targeting metacognitive beliefs could prove an effective therapeutic intervention for subjective cognitive impairments in these patients. PMID:27242634
Dynamic and static fatigue behavior of sintered silicon nitrides
NASA Technical Reports Server (NTRS)
Chang, J.; Khandelwal, P.; Heitman, P. W.
1987-01-01
The dynamic and static fatigue behavior of Kyocera SN220M sintered silicon nitride at 1000 C was studied. Fractographic analysis of the material failing in dynamic fatigue revealed the presence of slow crack growth (SCG) at stressing rates below 41 MPa/min. Under conditions of static fatigue this material also displayed SCG at stresses below 345 MPa. SCG appears to be controlled by microcracking of the grain boundaries. The crack velocity exponent (n) determined from both dynamic and static fatigue tests ranged from 11 to 16.
Dynamic Postural Control in Female Athletes and Nonathletes After a Whole-Body Fatigue Protocol.
Baghbani, Fatemeh; Woodhouse, Linda J; Gaeini, Abbas A
2016-07-01
Baghbani, F, Woodhouse, LJ, and Gaeini, AA. Dynamic postural control in female athletes and nonathletes after a whole-body fatigue protocol. J Strength Cond Res 30(7): 1942-1947, 2016-Postural control is a crucial element in regular training of athletes, development of complex technical movement, and injury prevention; however, distributing factor of the postural control such as fatigue has been neglected by athletic trainers in novice and inexperienced athletes. The objective of this study was to compare changes in dynamic postural control of young female athletes and nonathletes after a fatigue protocol. Thirty females (15 athletes and 15 nonathletes) with no orthopedic problems were recruited to participate in this study. All participants completed the pre-SEBT (star excursion balance test) in 8 directions at baseline; then, they performed a 20-minute fatigue protocol after which post-SEBT was measured. Rating of perceived exertion was measured using the Borg scale immediately before, mid-way through (i.e., after the third station), and after performing the fatigue protocol (i.e., immediately before the post-SEBT). Female nonathlete groups had significant differences in dynamic balance performance after fatigue in the medial, posteromedial, and posterior directions (p < 0.01) measured by SEBT. Athletes, however, showed no significant changes after the fatigue protocol. Our results indicates the importance of evaluation and monitoring of dynamic postural control of the novice with progressing the exercise time. Our findings could also help coaches to develop trainings focused on the 3 directions of medial, posteromedial, and posterior directions and aimed at exercises increasing fatigue resistance.
Ahn, Ick Keun; Kim, You Lim; Bae, Young-Hyeon; Lee, Suk Min
2015-01-01
Objectives. The purpose of this cross-sectional single-blind study was to investigate the immediate effects of Kinesiology taping of quadriceps on motor performance after muscle fatigued induction. Design. Randomized controlled cross-sectional design. Subjects. Forty-five subjects participated in this study. Participants were divided into three groups: Kinesiology taping group, placebo taping group, and nontaping group. Methods. Subjects performed short-term exercise for muscle fatigued induction, followed by the application of each intervention. Peak torque test, one-leg single hop test, active joint position sense test, and one-leg static balance test were carried out before and after the intervention. Results. Peak torque and single-leg hopping distance were significantly increased when Kinesiology taping was applied (p < 0.05). But there were no significant effects on active joint position sense and single-leg static balance. Conclusions. We proved that Kinesiology taping is effective in restoring muscle power reduced after muscle fatigued induction. Therefore, we suggest that Kinesiology taping is beneficial for fatigued muscles.
Ultrasonic fatigue of a high strength steel
NASA Astrophysics Data System (ADS)
Koster, M.; Wagner, G.; Eifler, D.
2010-07-01
At the Institute of Materials Science and Engineering at the University of Kaiserslautern an ultrasonic testing system for the fatigue assessment of metallic materials in the very high cycle fatigue (VHCF) regime was developed. The ultrasonic testing system allows to control the test and to measure detailed fatigue data. The achieved results can be used to describe the cyclic deformation behaviour of wheel steels at ultrasonic frequencies. In load increase tests (LIT), the critical stress amplitude can be determined, which leads to a defined change of process parameters like generator power, dissipated energy and specimen temperature. With SEM investigations it was proved that the change of the process parameters correlates with irreversible changes in the microstructure. It can be shown that the stress amplitude, leading to first irreversible changes in the microstructure, strongly depends on the depth position within the original wheel rim. New and basic results on the fatigue mechanisms of high strength steels in the VHCF-regime can be achieved.
The NASA Lewis Research Center High Temperature Fatigue and Structures Laboratory
NASA Technical Reports Server (NTRS)
Mcgaw, M. A.; Bartolotta, P. A.
1987-01-01
The physical organization of the NASA Lewis Research Center High Temperature Fatigue and Structures Laboratory is described. Particular attention is given to uniaxial test systems, high cycle/low cycle testing systems, axial torsional test systems, computer system capabilities, and a laboratory addition. The proposed addition will double the floor area of the present laboratory and will be equipped with its own control room.
Mechanical degradation of fuel cell membranes under fatigue fracture tests
NASA Astrophysics Data System (ADS)
Khorasany, Ramin M. H.; Sadeghi Alavijeh, Alireza; Kjeang, Erik; Wang, G. G.; Rajapakse, R. K. N. D.
2015-01-01
The effects of cyclic stresses on the fatigue and mechanical stability of perfluorosulfonic acid (PFSA) membranes are experimentally investigated under standard fuel cell conditions. The experiments are conducted ex-situ by subjecting membrane specimens to cyclic uniaxial tension at controlled temperature and relative humidity. The fatigue lifetime is measured in terms of the number of cycles until ultimate fracture. The results indicate that the membrane fatigue lifetime is a strong function of the applied stress, temperature, and relative humidity. The fatigue life increases exponentially with reduced stresses in all cases. The effect of temperature is found to be more significant than that of humidity, with reduced fatigue life at high temperatures. The maximum membrane strain at fracture is determined to decrease exponentially with increasing membrane lifetime. At a given fatigue life, a membrane exposed to fuel cell conditions is shown to accommodate more plastic strain before fracture than one exposed to room conditions. Overall, the proposed ex-situ membrane fatigue experiment can be utilized to benchmark the fatigue lifetime of new materials in a fraction of the time and cost associated with conventional in-situ accelerated stress testing methods.
NASA Astrophysics Data System (ADS)
Rao, K. Bhanu Sankara; Valsan, M.; Sandhya, R.; Mannan, S. L.; Rodriguez, P.
1993-04-01
The influence of prior cold work (PCW) on low-cycle fatigue (LCF) behavior of type 304 stainless steel has been studied at 300, 823, 923, and 1023 K by conducting total axial strain-controlled tests in solution annealed (SA, 0 pct PCW) condition and on specimens having three levels of PCW, namely, 10, 20, and 30 pct. A triangular waveform with a constant frequency of 0.1 Hz was employed for all of the tests performed over strain amplitudes in the range of ±0.25 to ± 1.25 pct. These studies have revealed that fatigue life is strongly dependent on PCW, temperature, and strain amplitude employed in testing. The SA material generally displayed better endurance in terms of total and plastic strain amplitudes than the material in 10, 20, and 30 pct PCW conditions at all of the temperatures. However, at 300 K at very low strain amplitudes, PCW material exhibited better total strain fatigue resistance. At 823 K, LCF life decreased with increasing PCW, whereas at 923 K, 10 pct PCW displayed the lowest life. An improvement in life occurred for prior deformations exceeding 10 pct at all strain amplitudes at 923 K. Fatigue life showed a noticeable decrease with increasing temperature up to 1023 K in PCW state. On the other hand, SA material displayed a minimum in fatigue life at 923 K. The fatigue life results of SA as well as all of the PCW conditions obeyed the Basquin and Coffin-Manson relationships at 300, 823, and 923 K. The constants and exponents in these equations were found to depend on the test temperature and prior metallurgical state of the material. A study is made of cyclic stress-strain behavior in SA and PCW states and the relationship between the cyclic strain-hardening exponent and fatigue behavior at different temperatures has been explored. The influence of environment on fatigue crack initiation and propagation behavior has been examined.
Myoelectrical Manifestation of Fatigue Less Prominent in Patients with Cancer Related Fatigue
Kisiel-Sajewicz, Katarzyna; Siemionow, Vlodek; Seyidova-Khoshknabi, Dilara; Davis, Mellar P.; Wyant, Alexandria; Ranganathan, Vinoth K.; Walsh, Declan; Yan, Jin H.; Hou, Juliet; Yue, Guang H.
2013-01-01
Purpose A lack of fatigue-related muscle contractile property changes at time of perceived physical exhaustion and greater central than peripheral fatigue detected by twitch interpolation technique have recently been reported in cancer survivors with fatigue symptoms. Based on these observations, it was hypothesized that compared to healthy people, myoelectrical manifestation of fatigue in the performing muscles would be less significant in these individuals while sustaining a prolonged motor task to self-perceived exhaustion (SPE) since their central fatigue was more prominent. The purpose of this study was to test this hypothesis by examining electromyographic (EMG) signal changes during fatiguing muscle performance. Methods Twelve individuals who had advanced solid cancer and cancer-related fatigue (CRF), and 12 age- and gender-matched healthy controls performed a sustained elbow flexion at 30% maximal voluntary contraction till SPE. Amplitude and mean power frequency (MPF) of EMG signals of the biceps brachii, brachioradialis, and triceps brachii muscles were evaluated when the individuals experienced minimal, moderate, and severe fatigue. Results CRF patients perceived physical “exhaustion” significantly sooner than the controls. The myoelectrical manifestation of muscular fatigue assessed by EMG amplitude and MPF was less significant in CRF than controls. The lower MPF even at minimal fatigue stage in CRF may indicate pathophysiologic condition of the muscle. Conclusions CRF patients experience less myoelectrical manifestation of muscle fatigue than healthy individuals near the time of SPE. The data suggest that central nervous system fatigue plays a more important role in limiting endurance-type of motor performance in patients with CRF. PMID:24391800
Dominelli, Paolo B; Molgat-Seon, Yannick; Griesdale, Donald E G; Peters, Carli M; Blouin, Jean-Sébastien; Sekhon, Mypinder; Dominelli, Giulio S; Henderson, William R; Foster, Glen E; Romer, Lee M; Koehle, Michael S; Sheel, A William
2017-08-01
High work of breathing and exercise-induced arterial hypoxaemia (EIAH) can decrease O 2 delivery and exacerbate exercise-induced quadriceps fatigue in healthy men. Women have a higher work of breathing during exercise, dedicate a greater fraction of whole-body V̇O2 towards their respiratory muscles and develop EIAH. Despite a greater reduction in men's work of breathing, the attenuation of quadriceps fatigue was similar between the sexes. The degree of EIAH was similar between sexes, and regardless of sex, those who developed the greatest hypoxaemia during exercise demonstrated the most attenuation of quadriceps fatigue. Based on our previous finding that women have a greater relative oxygen cost of breathing, women appear to be especially susceptible to work of breathing-related changes in quadriceps muscle fatigue. Reducing the work of breathing or eliminating exercise-induced arterial hypoxaemia (EIAH) during exercise decreases the severity of quadriceps fatigue in men. Women have a greater work of breathing during exercise, dedicate a greater fraction of whole-body V̇O2 towards their respiratory muscles, and demonstrate EIAH, suggesting women may be especially susceptible to quadriceps fatigue. Healthy subjects (8 male, 8 female) completed three constant load exercise tests over 4 days. During the first (control) test, subjects exercised at ∼85% of maximum while arterial blood gases and work of breathing were assessed. Subsequent constant load exercise tests were iso-time and iso-work rate, but with EIAH prevented by inspiring hyperoxic gas or work of breathing reduced via a proportional assist ventilator (PAV). Quadriceps fatigue was assessed by measuring force in response to femoral nerve stimulation. For both sexes, quadriceps force was equally reduced after the control trial (-27 ± 2% baseline) and was attenuated with hyperoxia and PAV (-18 ± 1 and -17 ± 2% baseline, P < 0.01, respectively), with no sex difference. EIAH was similar between the sexes, and regardless of sex, subjects with the lowest oxyhaemoglobin saturation during the control test had the greatest quadriceps fatigue attenuation with hyperoxia (r 2 = 0.79, P < 0.0001). For the PAV trial, despite reducing the work of breathing to a greater degree in men (men: 60 ± 5, women: 75 ± 6% control, P < 0.05), the attenuation of quadriceps fatigue was similar between the sexes (36 ± 4 vs. 37 ± 7%). Owing to a greater relative V̇O2 of the respiratory muscles in women, less of a change in work of breathing is needed to reduce quadriceps fatigue. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Damage mechanisms in alloy 800H under creep-fatigue conditions
NASA Astrophysics Data System (ADS)
Mu, Z.; Bothe, K.; Gerold, V.
1994-05-01
The interaction between fatigue damage (i.e., fatigue crack propagation) and internal grain boundary damage (i.e., cavity formation at grain boundaries) has been studied for the Alloy 800H at 750 C for constant plastic strain ranges but different experimental conditions. Most experiments were performed at constant ranges of alternating tensile/compression stresses. Symmetrical as well as asymmetrical tests (with larger compression stresses) were performed. In comparison to the former tests, asymmetrical tests led to shorter cyclic lifetimes mainly due to cavity formation which was not observed for symmetrical tests. It could be shown that a fast compressive and a slow tensile half cycle (at large compressive and low tensile stresses) are ideal conditions for the nucleation and growth of cavities. Based on quantitative measurements of the cavity density from interrupted fatigue tests, a physical model is presented which can predict the number of cycles to failure. This cycle number is determined only by fatigue crack growth which is controlled by (1) athermal plastic deformation, (2) creep deformation and (3) rate enhancement by cavitation.
Fatigue in primary Sjögren's syndrome is associated with lower levels of proinflammatory cytokines.
Howard Tripp, Nadia; Tarn, Jessica; Natasari, Andini; Gillespie, Colin; Mitchell, Sheryl; Hackett, Katie L; Bowman, Simon J; Price, Elizabeth; Pease, Colin T; Emery, Paul; Lanyon, Peter; Hunter, John; Gupta, Monica; Bombardieri, Michele; Sutcliffe, Nurhan; Pitzalis, Costantino; McLaren, John; Cooper, Annie; Regan, Marian; Giles, Ian; Isenberg, David A; Saravanan, Vadivelu; Coady, David; Dasgupta, Bhaskar; McHugh, Neil; Young-Min, Steven; Moots, Robert; Gendi, Nagui; Akil, Mohammed; Griffiths, Bridget; Lendrem, Dennis W; Ng, Wan-Fai
2016-01-01
This article reports relationships between serum cytokine levels and patient-reported levels of fatigue, in the chronic immunological condition primary Sjögren's syndrome (pSS). Blood levels of 24 cytokines were measured in 159 patients with pSS from the United Kingdom Primary Sjögren's Syndrome Registry and 28 healthy non-fatigued controls. Differences between cytokines in cases and controls were evaluated using Wilcoxon test. Patient-reported scores for fatigue were evaluated, classified according to severity and compared with cytokine levels using analysis of variance. Logistic regression was used to determine the most important predictors of fatigue levels. 14 cytokines were significantly higher in patients with pSS (n=159) compared to non-fatigued healthy controls (n=28). While serum levels were elevated in patients with pSS compared to healthy controls, unexpectedly, the levels of 4 proinflammatory cytokines-interferon-γ-induced protein-10 (IP-10) (p=0.019), tumour necrosis factor-α (p=0.046), lymphotoxin-α (p=0.034) and interferon-γ (IFN-γ) (p=0.022)-were inversely related to patient-reported levels of fatigue. A regression model predicting fatigue levels in pSS based on cytokine levels, disease-specific and clinical parameters, as well as anxiety, pain and depression, revealed IP-10, IFN-γ (both inversely), pain and depression (both positively) as the most important predictors of fatigue. This model correctly predicts fatigue levels with reasonable (67%) accuracy. Cytokines, pain and depression appear to be the most powerful predictors of fatigue in pSS. Our data challenge the notion that proinflammatory cytokines directly mediate fatigue in chronic immunological conditions. Instead, we hypothesise that mechanisms regulating inflammatory responses may be important.
Fatigue in primary Sjögren's syndrome is associated with lower levels of proinflammatory cytokines
Howard Tripp, Nadia; Tarn, Jessica; Natasari, Andini; Gillespie, Colin; Mitchell, Sheryl; Hackett, Katie L; Bowman, Simon J; Price, Elizabeth; Pease, Colin T; Emery, Paul; Lanyon, Peter; Hunter, John; Gupta, Monica; Bombardieri, Michele; Sutcliffe, Nurhan; Pitzalis, Costantino; McLaren, John; Cooper, Annie; Regan, Marian; Giles, Ian; Isenberg, David A; Saravanan, Vadivelu; Coady, David; Dasgupta, Bhaskar; McHugh, Neil; Young-Min, Steven; Moots, Robert; Gendi, Nagui; Akil, Mohammed; Griffiths, Bridget; Lendrem, Dennis W; Ng, Wan-Fai
2016-01-01
Objectives This article reports relationships between serum cytokine levels and patient-reported levels of fatigue, in the chronic immunological condition primary Sjögren's syndrome (pSS). Methods Blood levels of 24 cytokines were measured in 159 patients with pSS from the United Kingdom Primary Sjögren's Syndrome Registry and 28 healthy non-fatigued controls. Differences between cytokines in cases and controls were evaluated using Wilcoxon test. Patient-reported scores for fatigue were evaluated, classified according to severity and compared with cytokine levels using analysis of variance. Logistic regression was used to determine the most important predictors of fatigue levels. Results 14 cytokines were significantly higher in patients with pSS (n=159) compared to non-fatigued healthy controls (n=28). While serum levels were elevated in patients with pSS compared to healthy controls, unexpectedly, the levels of 4 proinflammatory cytokines—interferon-γ-induced protein-10 (IP-10) (p=0.019), tumour necrosis factor-α (p=0.046), lymphotoxin-α (p=0.034) and interferon-γ (IFN-γ) (p=0.022)—were inversely related to patient-reported levels of fatigue. A regression model predicting fatigue levels in pSS based on cytokine levels, disease-specific and clinical parameters, as well as anxiety, pain and depression, revealed IP-10, IFN-γ (both inversely), pain and depression (both positively) as the most important predictors of fatigue. This model correctly predicts fatigue levels with reasonable (67%) accuracy. Conclusions Cytokines, pain and depression appear to be the most powerful predictors of fatigue in pSS. Our data challenge the notion that proinflammatory cytokines directly mediate fatigue in chronic immunological conditions. Instead, we hypothesise that mechanisms regulating inflammatory responses may be important. PMID:27493792
Effect of stress concentration on the fatigue strength of A7N01S-T5 welded joints
NASA Astrophysics Data System (ADS)
Zhang, Mingyue; Gou, Guoqing; Hang, Zongqiu; Chen, Hui
2017-07-01
Stress concentration is a key factor that affects the fatigue strength of welded joints. In this study, the fatigue strengths of butt joints with and without the weld reinforcement were tested to quantify the effect of stress concentration. The fatigue strength of the welded joints was measured with a high-frequency fatigue machine. The P-S-N curves were drawn under different confidence levels and failure probabilities. The results show that butt joints with the weld reinforcement have much lower fatigue strength than joints without the weld reinforcement. Therefore, stress concentration introduced by the weld reinforcement should be controlled.
Amaral, Marina; Villefort, Regina F; Melo, Renata Marques; Pereira, Gabriel K R; Zhang, Yu; Valandro, Luiz Felipe; Bottino, Marco Antonio
2017-08-01
To determine the fatigue limits of three-unit monolithic zirconia fixed dental prosthesis (FDPs) before and after grinding of the gingival areas of connectors with diamond burs. FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue limits and standard deviations were obtained using a staircase fatigue method (n=20, 100,000 loading cycles/5Hz). The initial test load was 70% of the mean load-to-fracture (n=3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student's T-test (α≤0.05). Both the control and ground groups exhibited similar values of load-to-fracture and fatigue limits. Neither the surface treatments nor ageing affected the surface roughness of the specimens. The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue limit of the three-unit monolithic zirconia FDP. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effects of processing on the transverse fatigue properties of low-sulfur AISI 4140 steel
NASA Astrophysics Data System (ADS)
Collins, Sunniva R.; Michal, Gary M.
1993-12-01
The effects of inclusions due to steelmaking processes on the fatigue life of AISI 4140 have been investigated. The test matrix consisted of three commercially produced heats of AISI 4140 of comparable cleanliness: one was conventionally cast (CC), and two were inert gas-shielded/ bottom-poured (IGS). One of the IGS heats was calcium-treated to explore the effects of inclusion shape control (IGS/SC). All heats were hot-rolled and reduced over 95 pct to produce bar stock of 127 to 152 mm (5 to 6 in.) in diameter. Transverse axial specimens conforming to ASTM E466 were machined, quenched, and tempered to approximately 40 HRC, and they were fatigue tested in tension-tension cycling ( R = 0.1). Test results and statistical analyses of the stress-life data show that the IGS grade has several times the fatigue strength of the CC grade at 107 cycles. Lower-limit fatigue strengths calculated at a 99.9 pct probability were 518.5 MPa (75.2 ksi) for IGS vs 55.6 MPa (8.1 ksi) for the CC grade. The IGS/SC grade had the best performance at all stress and life levels. The results obtained indicate that fatigue performance can be improved by choosing a processing method that reduces the incidence of exogenous oxides and by controlling the shape of the sulfides.
NASA Astrophysics Data System (ADS)
Ji, Dongmei; Ren, Jianxing; Zhang, Lai-Chang
2016-11-01
A novel creep-fatigue life prediction model was deduced based on an expression of the strain energy density in this study. In order to obtain the expression of the strain energy density, the load-controlled creep-fatigue (CF) tests of P92 steel at 873 K were carried out. Cyclic strain of P92 steel under CF load was divided into elastic strain, applying and unloading plastic strain, creep strain, and anelastic strain. Analysis of cyclic strain indicates that the damage process of P92 steel under CF load consists of three stages, similar to pure creep. According to the characteristics of the strains above, an expression was defined to describe the strain energy density for each cycle. The strain energy density at stable stage is inversely proportional to the total strain energy density dissipated by P92 steel. However, the total strain energy densities under different test conditions are proportional to the fatigue life. Therefore, the expression of the strain energy density at stable stage was chosen to predict the fatigue life. The CF experimental data on P92 steel were employed to verify the rationality of the novel model. The model obtained from the load-controlled CF test of P92 steel with short holding time could predict the fatigue life of P92 steel with long holding time.
Exercise capacity, muscle strength and fatigue in sarcoidosis.
Marcellis, R G J; Lenssen, A F; Elfferich, M D P; De Vries, J; Kassim, S; Foerster, K; Drent, M
2011-09-01
The aim of this case-control study was to investigate the prevalence of exercise intolerance, muscle weakness and fatigue in sarcoidosis patients. Additionally, we evaluated whether fatigue can be explained by exercise capacity, muscle strength or other clinical characteristics (lung function tests, radiographic stages, prednisone usage and inflammatory markers). 124 sarcoidosis patients (80 males) referred to the Maastricht University Medical Centre (Maastricht, the Netherlands) were included (mean age 46.6±10.2 yrs). Patients performed a 6-min walk test (6MWT) and handgrip force (HGF), elbow flexor muscle strength (EFMS), quadriceps peak torque (QPT) and hamstring peak torque (HPT) tests. Maximal inspiratory pressure (P(I,max)) was recorded. All patients completed the Fatigue Assessment Scale (FAS) questionnaire. The 6MWT was reduced in 45% of the population, while HGF, EFMS, QPT and HPT muscle strength were reduced in 15, 12, 27 and 18%, respectively. P(I,max) was reduced in 43% of the population. The majority of the patients (81%) reported fatigue (FAS ≥22). Patients with reduced peripheral muscle strength of the upper and/or lower extremities were more fatigued and demonstrated impaired lung functions, fat-free mass, P(I,max), 6MWT and quality of life. Fatigue was neither predicted by exercise capacity, nor by muscle strength. Besides fatigue, exercise intolerance and muscle weakness are frequent problems in sarcoidosis. We therefore recommend physical tests in the multidisciplinary management of sarcoidosis patients, even in nonfatigued patients.
NASA Astrophysics Data System (ADS)
Seifi, Mohsen; Dahar, Matthew; Aman, Ron; Harrysson, Ola; Beuth, Jack; Lewandowski, John J.
2015-03-01
This preliminary work documents the effects of test orientation with respect to build and beam raster directions on the fracture toughness and fatigue crack growth behavior of as-deposited EBM Ti-6Al-4V. Although ASTM/ISO standards exist for determining the orientation dependence of various mechanical properties in both cast and wrought materials, these standards are evolving for materials produced via additive manufacturing (AM) techniques. The current work was conducted as part of a larger America Makes funded project to begin to examine the effects of process variables on the microstructure and fracture and fatigue behavior of AM Ti-6Al-4V. In the fatigue crack growth tests, the fatigue threshold, Paris law slope, and overload toughness were determined at different load ratios, R, whereas fatigue precracked samples were tested to determine the fracture toughness. The as-deposited material exhibited a fine-scale basket-weave microstructure throughout the build, and although fracture surface examination revealed the presence of unmelted powders, disbonded regions, and isolated porosity, the resulting mechanical properties were in the range of those reported for cast and wrought Ti-6Al-4V. Remote access and control of testing was also developed at Case Western Reserve University to improve efficiency of fatigue crack growth testing.
NASA Technical Reports Server (NTRS)
Yun, Gunjin; Abdullah, A. B. M.; Binienda, Wieslaw; Krause, David L.; Kalluri, Sreeramesh
2014-01-01
A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses
US/Australia Collaborative Research Project on Corrosion Fatigue in D6AC Steel Joints
1978-12-01
Life of Exposure Groups at 80,000 psi Max Load Level (R=0.1) 77 10 Location of Observable Fatigue Cracks on Failed D6AC Steel Specimen Surfaces 78 11...ing the machining and assembly process. Such liquids might have a serious deleterious effect on the fatigue life of the aircraft. Further, there was...control tests were to provide a base for determining the various corrosion effects on fatigue life , and to deter- mine any differences in laboratory
The role of cyclic plastic zone size on fatigue crack growth behavior in high strength steels
NASA Astrophysics Data System (ADS)
Korda, Akhmad A.; Miyashita, Y.; Mutoh, Y.
2015-09-01
The role of cyclic plastic zone in front of the crack tip was studied in high strength steels. Estimated plastic zone size would be compared with actual observation. Strain controlled fatigue tests of the steels were carried out to obtain cyclic stress-strain curves for plastic zone estimation. Observations of plastic zone were carried out using in situ SEM fatigue crack growth tests under a constant-ΔK. Hard microstructures in structural steels showed to inhibit the extent of plastic deformation around the crack tip. The rate of crack growth can be correlated with the size of plastic zone. The smaller the plastic zone size, the slower the fatigue crack growth.
McElhiney, Martin; Rabkin, Judith; Van Gorp, Wilfred; Rabkin, Richard
2010-06-01
Both mild cognitive impairment and fatigue are common among people with HIV/AIDS. This study examined the efficacy of modafinil for HIV+ patients who sought treatment for fatigue in a placebo-controlled double-blind 4-week trial. A battery of standard neuropsychological tests was administered at study entry and Week 4, and change in performance was compared for 59 patients receiving modafinil versus 44 patients receiving placebo. A significant effect on fatigue was observed. In addition, cognitive performance, as measured by a global change score, improved more in the modafinil than in the placebo group although the effect was not specific to any cognitive domain.
NASA Astrophysics Data System (ADS)
Torries, Brian; Shamsaei, Nima
2017-12-01
The effects of different cooling rates, as achieved by varying the interlayer time interval, on the fatigue behavior of additively manufactured Ti-6Al-4V specimens were investigated and modeled via a microstructure-sensitive fatigue model. Comparisons are made between two sets of specimens fabricated via Laser Engineered Net Shaping (LENS™), with variance in interlayer time interval accomplished by depositing either one or two specimens per print operation. Fully reversed, strain-controlled fatigue tests were conducted, with fractography following specimen failure. A microstructure-sensitive fatigue model was calibrated to model the fatigue behavior of both sets of specimens and was found to be capable of correctly predicting the longer fatigue lives of the single-built specimens and the reduced scatter of the double-built specimens; all data points fell within the predicted upper and lower bounds of fatigue life. The time interval effects and the ability to be modeled are important to consider when producing test specimens that are smaller than the production part (i.e., property-performance relationships).
NASA Technical Reports Server (NTRS)
Dicus, D. L.
1984-01-01
The effects of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate at frequencies of 1 Hz and 10 Hz were investigated. Twenty-five mm thick compact specimens were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Fatigue crack growth rates were calculated from effective crack lengths determined using a compliance method. Tests were conducted in hard vacuum and at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. Fatigue crack growth rates were frequency insensitive under all environment conditions tested. For constant stress intensity factor ranges crack growth rate transitions occurred at low and high water vapor pressures. Crack growth rates at intermediate pressures were relatively constant and showed reasonable agreement with published data for two Al-Cu-Mg alloys. The existence of two crack growth rate transitions suggests either a change in rate controlling kinetics or a change in corrosion fatigue mechanism as a function of water vapor pressure. Reduced residual deformation and transverse cracking specimens tested in water vapor versus vacuum may be evidence of embrittlement within the plastic zone due to environmental interaction.
NASA Technical Reports Server (NTRS)
Dicus, D. L.
1982-01-01
The effects of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate at frequencies of 1 Hz and 10 Hz were investigated. Twenty-five mm thick compact specimens were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Fatigue crack growth rates were calculated from effective crack lengths determined using a compliance method. Tests were conducted in hard vacuum and at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. Fatigue crack growth rates were frequency insensitive under all environment conditions tested. For constant stress intensity factor ranges crack growth rate transitions occurred at low and high water vapor pressures. Crack growth rates at intermediate pressures were relatively constant and showed reasonable agreement with published data for two Al-Cu-Mg alloys. The existence of two crack growth rate transitions suggests either a change in rate controlling kinetics or a change in corrosion fatigue mechanism as a function of water vapor pressure. Reduced residual deformation and transverse cracking specimens tested in water vapor versus vacuum may be evidence of embrittlement within the plastic zone due to environmental interaction.
Vardy, J. L.; Dhillon, H. M.; Pond, G. R.; Renton, C.; Dodd, A.; Zhang, H.; Clarke, S. J.; Tannock, I. F.
2016-01-01
Background Fatigue is associated with cancer and chemotherapy and may be sustained. Here, we describe a prospective longitudinal study evaluating fatigue and putative mechanisms in people with colorectal cancer (CRC). Patients and methods People with localized CRC completed the Functional Assessment of Cancer Treatment-Fatigue (FACT-F) questionnaire at baseline (before chemotherapy, if given), 6, 12, and 24 months. Healthy controls (HCs) were assessed at the first three time points. Fatigue was defined by standardized FACT-F scores ≤68/100. Quality-of-life (QoL, assessed by the FACT-G questionnaire), affective, and cognitive symptoms were evaluated. Associations were sought between fatigue, baseline factors, and blood tests (including hemoglobin, cytokines, and sex hormones). Regression analyses, Fisher's exact tests, and Wilcoxon rank-sum tests assessed levels of fatigue at each time point and change in fatigue from baseline. A repeated-measures analysis investigated prognostic factors of fatigue across all time points. Results A total of 289 subjects with localized CRC (173 received chemotherapy) and 72 HCs were assessed. More CRC patients had fatigue than HCs at baseline (52% versus 26%, P < 0.001). Fatigue was increased in the chemotherapy (CTh) group at 6 months [CTh+ 70% versus CTh− 31% (P < 0.001), HCs 22%] and remained more common at 12 [CTh+ 44% versus CTh− 31% (P = 0.079)] and 24 months [CTh+ 39% versus CTh− 24% (P = 0.047)]. There was no significant difference between those not receiving chemotherapy and HCs at follow-up assessments. Fatigue was associated with poor QoL, affective and cognitive symptoms, but not consistently with cytokine levels. Predictors for sustained fatigue were baseline fatigue, treatment group, cognitive and affective symptoms, poorer QoL, and comorbidities. Conclusions CRC patients have more fatigue than HCs at baseline. Fatigue peaks immediately after adjuvant chemotherapy, but remains common for 2 years in those who receive chemotherapy. Cognitive and affective symptoms, QoL, comorbidities, chemotherapy, and baseline fatigue predict for longer term fatigue. PMID:27443634
NASA Astrophysics Data System (ADS)
McCullough, R. R.; Jordon, J. B.; Brammer, A. T.; Manigandan, K.; Srivatsan, T. S.; Allison, P. G.; Rushing, T. W.
2014-01-01
In this paper, the use of a microstructure-sensitive fatigue model is put forth for the analysis of discontinuously reinforced aluminum alloy metal matrix composite. The fatigue model was used for a ceramic particle-reinforced aluminum alloy deformed under conditions of fully reversed strain control. Experimental results revealed the aluminum alloy to be strongly influenced by volume fraction of the particulate reinforcement phase under conditions of strain-controlled fatigue. The model safely characterizes the evolution of fatigue damage in this aluminum alloy composite into the distinct stages of crack initiation and crack growth culminating in failure. The model is able to capture the specific influence of particle volume fraction, particle size, and nearest neighbor distance in quantifying fatigue life. The model yields good results for correlation of the predicted results with the experimental test results on the fatigue behavior of the chosen aluminum alloy for two different percentages of the ceramic particle reinforcement. Further, the model illustrates that both particle size and volume fraction are key factors that govern fatigue lifetime. This conclusion is well supported by fractographic observations of the cyclically deformed and failed specimens.
Validation of the Fatigue Impact Scale in Hungarian patients with multiple sclerosis.
Losonczi, Erika; Bencsik, Krisztina; Rajda, Cecília; Lencsés, Gyula; Török, Margit; Vécsei, László
2011-03-01
Fatigue is one of the most frequent complaints of patients with multiple sclerosis (MS). The Fatigue Impact Scale (FIS), one of the 30 available fatigue questionnaires, is commonly applied because it evaluates multidimensional aspects of fatigue. The main purposes of this study were to test the validity, test-retest reliability, and internal consistency of the Hungarian version of the FIS. One hundred and eleven MS patients and 85 healthy control (HC) subjects completed the FIS and the Beck Depression Inventory, a large majority of them on two occasions, 3 months apart. The total FIS score and subscale scores differed statistically between the MS patients and the HC subjects in both FIS sessions. In the test-retest reliability assessment, statistically, the intraclass correlation coefficients were high in both the MS and HC groups. Cronbach's alpha values were also notably high. The results of this study indicate that the FIS can be regarded as a valid and reliable scale with which to improve our understanding of the impact of fatigue on the health-related quality of life in MS patients without severe disability.
Yokota, Yuki; Sonoda, Takuya; Tashiro, Yuto; Suzuki, Yusuke; Kajiwara, Yu; Zeidan, Hala; Nakayama, Yasuaki; Kawagoe, Mirei; Shimoura, Kanako; Tatsumi, Masataka; Nakai, Kengo; Nishida, Yuichi; Bito, Tsubasa; Yoshimi, Soyoka; Aoyama, Tomoki
2018-05-01
[Purpose] This study aimed to clarify the effects of Capacitive and Resistive electric transfer (CRet) on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise. [Subjects and Methods] Twenty-two healthy males were assigned into either the CRet (n=11) or control (n=11) group. Fatiguing exercise and CRet intervention were applied at the quadriceps muscle of the participants' dominant legs. The Ely test, pelvic tilt, lumbar lordosis, and superficial temperature were measured before and after exercise and for 30 minutes after intervention. Statistical analysis was performed using one-way analysis of variance, with Tukey's post-hoc multiple comparison test to clarify within-group changes and Student's t-test to clarify between-group differences. [Results] The Ely test and pelvic tilt were significantly different in both groups after exercise, but there was no difference in the CRet group after intervention. Superficial temperature significantly increased in the CRet group for 30 minutes after intervention, in contrast to after the exercise and intervention in the control group. There was no significant between-group difference at any timepoint, except in superficial temperature. [Conclusion] CRet could effectively improve muscle flexibility and lumbopelvic alignment after fatiguing exercise.
Yokota, Yuki; Sonoda, Takuya; Tashiro, Yuto; Suzuki, Yusuke; Kajiwara, Yu; Zeidan, Hala; Nakayama, Yasuaki; Kawagoe, Mirei; Shimoura, Kanako; Tatsumi, Masataka; Nakai, Kengo; Nishida, Yuichi; Bito, Tsubasa; Yoshimi, Soyoka; Aoyama, Tomoki
2018-01-01
[Purpose] This study aimed to clarify the effects of Capacitive and Resistive electric transfer (CRet) on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise. [Subjects and Methods] Twenty-two healthy males were assigned into either the CRet (n=11) or control (n=11) group. Fatiguing exercise and CRet intervention were applied at the quadriceps muscle of the participants’ dominant legs. The Ely test, pelvic tilt, lumbar lordosis, and superficial temperature were measured before and after exercise and for 30 minutes after intervention. Statistical analysis was performed using one-way analysis of variance, with Tukey’s post-hoc multiple comparison test to clarify within-group changes and Student’s t-test to clarify between-group differences. [Results] The Ely test and pelvic tilt were significantly different in both groups after exercise, but there was no difference in the CRet group after intervention. Superficial temperature significantly increased in the CRet group for 30 minutes after intervention, in contrast to after the exercise and intervention in the control group. There was no significant between-group difference at any timepoint, except in superficial temperature. [Conclusion] CRet could effectively improve muscle flexibility and lumbopelvic alignment after fatiguing exercise. PMID:29765189
Karataşlıoglu, E; Aydın, U; Yıldırım, C
2018-02-01
The aim of this in vitro study was to compare the static cyclic fatigue resistance of thermal treated rotary files with a conventional nickel-titanium (NiTi) rotary file. Four groups of 60 rotary files with similar file dimensions, geometries, and motion were selected. Groups were set as HyFlex Group [controlled memory wire (CM-Wire)], ProfileVortex Group (M-Wire), Twisted File Group (R-Phase Wire), and OneShape Group (conventional NiTi wire)] and tested using a custom-made static cyclic fatigue testing apparatus. The fracture time and fragment length of the each file was also recorded. Statistical analysis was performed using one-way analysis of variance and Tukey's test at the 95% confidence level (P = 0.05). The HyFlex group had a significantly higher mean cyclic fatigue resistance than the other three groups (P < 0.001). The OneShape groups had the least fatigue resistance. CM-Wire alloy represented the best performance in cyclic fatigue resistance, and NiTi alloy in R-Phase had the second highest fatigue resistance. CM and R-Phase manufacturing technology processed to the conventional NiTi alloy enhance the cyclic fatigue resistance of files that have similar design and size. M-wire alloy did not show any superiority in cyclic fatigue resistance when compared with conventional NiTi wire.
Lenaert, Bert; Jansen, Rebecca; van Heugten, Caroline M
2018-04-01
Chronic fatigue is highly prevalent in the general population as well as in multiple chronic diseases and psychiatric disorders. Its etiology however remains poorly understood and cannot be explained by biological factors alone. Occurring in a psychosocial context, the experience and communication of fatigue may be shaped by social interactions. In particular, interpersonal operant conditioning may strengthen and perpetuate fatigue complaints. In this experiment, individuals (N = 44) repeatedly rated their currently experienced fatigue while engaging in cognitive effort (working memory task). Subtle social reward was given when fatigue increased relative to the previous rating; or disapproval when fatigue decreased. In the control condition, only neutral feedback was given. Although all participants became more fatigued during cognitive effort, interpersonal operant conditioning led to increased fatigue reporting relative to neutral feedback. This effect occurred independently of conscious awareness. Interestingly, the experimental condition also performed worse on the working memory task. Results suggest that fatigue complaints (and cognitive performance) may become controlled by their consequences such as social reward, and not exclusively by their antecedents such as effort. Results have implications for treatment development and suggest that interpersonal operant conditioning may contribute to fatigue becoming a chronic symptom. Copyright © 2018 Elsevier Ltd. All rights reserved.
Saxby, Dyani J.; Matthews, Gerald; Warm, Joel S.; Hitchcock, Edward M.; Neubauer, Catherine
2015-01-01
Despite the known dangers of driver fatigue, it is a difficult construct to study empirically. Different forms of task-induced fatigue may differ in their effects on driver performance and safety. Desmond and Hancock (2001) defined active and passive fatigue states that reflect different styles of workload regulation. In 2 driving simulator studies we investigated the multidimensional subjective states and safety outcomes associated with active and passive fatigue. Wind gusts were used to induce active fatigue, and full vehicle automation to induce passive fatigue. Drive duration was independently manipulated to track the development of fatigue states over time. Participants were undergraduate students. Study 1 (N = 108) focused on subjective response and associated cognitive stress processes, while Study 2 (N = 168) tested fatigue effects on vehicle control and alertness. In both studies the 2 fatigue manipulations produced different patterns of subjective response reflecting different styles of workload regulation, appraisal, and coping. Active fatigue was associated with distress, overload, and heightened coping efforts, whereas passive fatigue corresponded to large-magnitude declines in task engagement, cognitive underload, and reduced challenge appraisal. Study 2 showed that only passive fatigue reduced alertness, operationalized as speed of braking and steering responses to an emergency event. Passive fatigue also increased crash probability, but did not affect a measure of vehicle control. Findings support theories that see fatigue as an outcome of strategies for managing workload. The distinction between active and passive fatigue is important for assessment of fatigue and for evaluating automated driving systems which may induce dangerous levels of passive fatigue. PMID:24041288
A tension-torsional fatigue testing apparatus for micro-scale components.
Fu, Sichao; Wang, Lei; Chen, Gang; Yu, Dunji; Chen, Xu
2016-01-01
Mechanical characterization of micro-scale components under complex loading conditions is a great challenge. To meet such a challenge, a microtension-torsional fatigue testing apparatus is developed in this study that specializes in the evaluation of multiaxial fatigue behavior of thin stent wires. The actuation and measurement in two controlled directions are incorporated in the tensile and torsional load frames, respectively, and a thrust air bearing is applied for the coupling of the two frames. The axial deformation of specimens measured by a grating sensor built in the linear motor and by a non-contact displacement detect system is compared and corrected. The accuracy of the torque measurement is proved by torsion tests on thin wires of 316L stainless steel in nominal diameters of 100 μm. Multistep torsion test, multiaxial ratcheting test, and a fully strain controlled multiaxial cyclic test are performed on 100 μm and 200 μm-diameter 316L wires using this apparatus. The capability of the equipment in tension-torsional cyclic tests for micro-scale specimens is demonstrated by the experimental results.
A tension-torsional fatigue testing apparatus for micro-scale components
NASA Astrophysics Data System (ADS)
Fu, Sichao; Wang, Lei; Chen, Gang; Yu, Dunji; Chen, Xu
2016-01-01
Mechanical characterization of micro-scale components under complex loading conditions is a great challenge. To meet such a challenge, a microtension-torsional fatigue testing apparatus is developed in this study that specializes in the evaluation of multiaxial fatigue behavior of thin stent wires. The actuation and measurement in two controlled directions are incorporated in the tensile and torsional load frames, respectively, and a thrust air bearing is applied for the coupling of the two frames. The axial deformation of specimens measured by a grating sensor built in the linear motor and by a non-contact displacement detect system is compared and corrected. The accuracy of the torque measurement is proved by torsion tests on thin wires of 316L stainless steel in nominal diameters of 100 μm. Multistep torsion test, multiaxial ratcheting test, and a fully strain controlled multiaxial cyclic test are performed on 100 μm and 200 μm-diameter 316L wires using this apparatus. The capability of the equipment in tension-torsional cyclic tests for micro-scale specimens is demonstrated by the experimental results.
Ragnarsson, Oskar; Berglund, Peter; Eder, Derek N; Johannsson, Gudmundur
2012-09-01
Cognitive function is impaired in patients with active Cushing's syndrome (CS). The aim was to study cognitive function in patients with CS in long-term remission. We conducted a cross-sectional, case-controlled, single center study. Fifty-five patients previously treated for Cushing's disease (n = 43) and cortisol-producing adrenal adenoma (n = 12) and 55 controls matched for age, gender, and educational level participated in the study. Working memory, attention, information-processing speed, verbal fluency, and reading speed were studied using standardized neuropsychological testing and alerting, orienting, and executive control using the Attentional Network Test. Fatigue impact scale and the comprehensive psychopathological rating scale were used to evaluate fatigue and affective disorder. Median (interquartile range) duration of remission was 13 (5-19) yr and the mean ± SD age at follow-up was 54 ± 14 yr. Compared to controls, patients had a higher score on the fatigue impact scale, indicating greater burdens of fatigue, and a higher score on the comprehensive psychopathological rating scale subscales for depression and anxiety. In a multivariate analysis, attention, spatial orienting, alerting, working memory, verbal fluency, and reading speed were all diminished in comparison to controls, independent of scores for affective disorder and fatigue. No overall difference in outcome was seen between patients in long-term remission for Cushing's disease and cortisol-producing adrenal adenoma. Patients with CS in remission have impaired cognitive function that cannot be explained by the coexistence of affective disorder or chronic fatigue. The pattern of cognitive and attentional deficits suggests a more global involvement of the brain function than has previously been suggested.
Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments.
Capar, Ismail Davut; Ertas, Huseyin; Arslan, Hakan
2015-04-01
New files (ProTaper Next/HyFlex/OneShape) are made from novel nickel-titanium (NiTi) alloys/treatments. The purpose of this study was to compare the cyclic fatigue resistance of these new instruments with that of Revo-S instruments. Four groups of 20 NiTi endodontic instruments were tested in steel canals with a 3 mm radius and a 60° angle of curvature. The cyclic fatigue of the following NiTi instruments with a tip size 25 and 0.06 taper that were manufactured with different alloys was tested: ProTaper Next X2 (M-Wire), OneShape (conventional NiTi), Revo-S Shaping Universal (conventional NiTi) and HyFlex 25/0.6 (controlled memory NiTi wire). A one-way anova and post-hoc Tukey's test (α = 0.05) revealed that the HyFlex files had the highest fatigue resistance and the Revo-S had the least fatigue resistance among the groups (P < 0.001). © 2014 Australian Society of Endodontology.
Effect of helium to dpa ratio on fatigue behavior of austenitic stainless steel irradiated to 2 dpa
NASA Astrophysics Data System (ADS)
Ioka, I.; Yonekawa, M.; Miwa, Y.; Mimura, H.; Tsuji, H.; Hoshiya, T.
2000-12-01
The effect of helium due to nuclear transmutation reactions during neutron irradiation on low cycle fatigue life of type 304 stainless steel was investigated. The specimens were irradiated in spectrally tailored capsules in the Japan Materials Testing Reactor (JMTR) at a temperature of 823 K to a neutron fluence of approximately 1×1025 n/m2 (E>1 MeV) and helium levels of 0.8, 2.5 and 8.1 appm. The low cycle fatigue tests were performed in total axial strain ranges of 0.8-1.6% at 823 K. A laser extensometer was used for controlling the axial strain of a specimen under cyclic testing. The difference between unirradiated and irradiated specimens is quite clear and appears to be a reduction by a factor of 2-5 in fatigue life. The helium concentration of the specimen is not the main factor to shorten fatigue life in the present experimental condition.
Bithermal Low-Cycle Fatigue Evaluation of Automotive Exhaust System Alloy SS409
NASA Technical Reports Server (NTRS)
Lu, Gui-Ying; Behling, Mike B.; Halford, Gary R.
2000-01-01
This investigation provides, for the first time, cyclic strainrange-controlled, thermomechanical fatigue results for the ferritic stainless steel alloy SS409. The alloy has seen extensive application for automotive exhaust system components. The data were generated to calibrate the Total Strain Version of the Strainrange Partitioning (TS-SRP) method for eventual application to the design and durability assessment of automotive exhaust systems. The thermomechanical cyclic lifetime and cyclic stress-strain constitutive behavior for alloy SS409 were measured using bithermal tests cycling between isothermal extremes of 400 and 800 C. Lives ranged up to 10,000 cycles to failure with hold-times of 0.33 to 2.0 minutes. The bithermal fatigue behavior is compared to isothermal, strain-controlled fatigue behavior at both 400 and 800 C. Thermomechanical cycling was found to have a profound detrimental influence on the fatigue failure resistance of SS409 compared to isothermal cycling. Supplementary bithermal cyclic stress-strain constitutive tests with hold-times ranging from 40 seconds up to 1.5 hours were conducted to calibrate the TS-SRP equation for extrapolation to longer lifetime predictions. Observed thermomechanical (bithermal) fatigue lives correlated well with lives calculated using the calibrated TS-SRP equations: 70% of the bithermal fatigue data fall within a factor of 1.2 of calculated life; 85% within a factor of 1.4; and 100% within a factor of 1.8.
Katz, Ben Z.; Boas, Steven; Shiraishi, Yukiko; Mears, Cynthia J.; Taylor, Renee
2010-01-01
Objective Six months following acute infectious mononucleosis (IM), 13%, of adolescents meet criteria for chronic fatigue syndrome (CFS). We measured exercise tolerance in adolescents with CFS and controls 6 months following IM. Study design 21 adolescents with CFS 6 months following IM and 21 recovered controls performed a maximal incremental exercise tolerance test with breath-by-breath gas analysis. Values expressed are mean ± standard deviation. Results The adolescents diagnosed with CFS and controls did not differ in age, weight, body-mass index or peak work capacity. Lower VO2 (oxygen consumption) peak percent of predicted was seen in adolescents with CFS compared with controls (CFS 99.3 ± 16.6 vs control 110.7 ± 19.9, p = 0.05). Peak oxygen pulse also was lower in adolescents with CFS compared with recovered controls (CFS 12.4 ± 2.9 vs controls 14.9 ± 4.3, p = 0.03). Conclusions Adolescents with CFS 6 months following IM have a lower degree of fitness and efficiency of exercise than recovered adolescents. Whether these abnormal exercise findings are a cause or effect of CFS is unknown. IM can lead to both fatigue and measurable changes in exercise testing in a subset of adolescents. PMID:20447647
The use of fatigue tests in the manufacture of automotive steel wheels.
NASA Astrophysics Data System (ADS)
Drozyner, P.; Rychlik, A.
2016-08-01
Production for the automotive industry must be particularly sensitive to the aspect of safety and reliability of manufactured components. One of such element is the rim, where durability is a feature which significantly affects the safety of transport. Customer complaints regarding this element are particularly painful for the manufacturer because it is almost always associated with the event of accident or near-accident. Authors propose original comprehensive method of quality control at selected stages of rims production: supply of materials, production and pre-shipment inspections. Tests by the proposed method are carried out on the originally designed inertial fatigue machine The machine allows bending fatigue tests in the frequency range of 0 to 50 Hz at controlled increments of vibration amplitude. The method has been positively verified in one of rims factory in Poland. Implementation resulted in an almost complete elimination of complaints resulting from manufacturing and material errors.
Positive inotropism in mammalian skeletal muscle in vitro during and after fatigue.
Reading, S A; Murrant, C L; Barclay, J K
2004-04-01
We tested the hypothesis that positive inotropic factors decrease fatigue and improve recovery from fatigue in mammalian skeletal muscle in vitro. To induce fatigue, we stimulated mouse soleus and extensor digitorum longus (EDL) to perform isometric tetanic contractions (50 impulses x s(-1) for 0.5 s) at 6 contractions x min(-1) for 60 min in soleus and 3 contractions x min(-1) for 20 min in EDL. Muscles were submerged in Krebs-Henseleit bicarbonate solution (Krebs) at 27 degrees C gassed with 95% nitrogen - 5% carbon dioxide (anoxia). Before and for 67 min after the fatigue period, muscles contracted at 0.6 contractions x min(-1) in 95% oxygen - 5% carbon dioxide (hyperoxia). We added a permeable cAMP analog (N6, 2'-O-dibutyryladenosine 3':5'-cyclic monophosphate at 10(-3) mol x L(-1) (dcAMP)), caffeine (2 x 10(-3) mol x L(-1), or Krebs as vehicle control at 25 min before, during, or at the end of the fatigue period. In soleus and EDL, both challenges added before fatigue significantly increased developed force but only caffeine increased developed force when added during the fatigue period. At the end of fatigue, the decrease in force in challenged muscles was equal to or greater than in controls so that the force remaining was the same or less than in controls. EDL challenged with dcAMP or caffeine at any time recovered more force than controls. In soleus, caffeine improved recovery except when added before fatigue. With dcAMP added to soleus, recovery was better after challenges at 10 min and the end of the fatigue period. Thus, increased intracellular concentrations of cAMP and (or) Ca2+ did not decrease fatigue in either muscle but improved recovery from fatigue in EDL and, in some conditions, in soleus.
Fatigue Behavior and Deformation Mechanisms in Inconel 718 Superalloy Investigated
NASA Technical Reports Server (NTRS)
2005-01-01
The nickel-base superalloy Inconel 718 (IN 718) is used as a structural material for a variety of components in the space shuttle main engine (SSME) and accounts for more than half of the total weight of this engine. IN 718 is the bill-of-material for the pressure vessels of nickel-hydrogen batteries for the space station. In the case of the space shuttle main engine, structural components are typically subjected to startup and shutdown load transients and occasional overloads in addition to high-frequency vibratory loads from routine operation. The nickel-hydrogen battery cells are prooftested before service and are subjected to fluctuating pressure loads during operation. In both of these applications, the structural material is subjected to a monotonic load initially, which is subsequently followed by fatigue. To assess the life of these structural components, it is necessary to determine the influence of a prior monotonic load on the subsequent fatigue life of the superalloy. An insight into the underlying deformation and damage mechanisms is also required to properly account for the interaction between the prior monotonic load and the subsequent fatigue loading. An experimental investigation was conducted to establish the effect of prior monotonic straining on the subsequent fatigue behavior of wrought, double-aged, IN 718 at room temperature. First, monotonic strain tests and fully-reversed, strain-controlled fatigue tests were conducted on uniform-gage-section IN 718 specimens. Next, fully reversed fatigue tests were conducted under strain control on specimens that were monotonically strained in tension. Results from this investigation indicated that prior monotonic straining reduced the fatigue resistance of the superalloy particularly at the lowest strain range. Some of the tested specimens were sectioned and examined by transmission electron microscopy to reveal typical microstructures as well as the active deformation and damage mechanisms under each of the loading conditions. In monotonically strained specimens, deformation during the subsequent fatigue loading was mainly confined to the deformation bands initiated during the prior monotonic straining. This can cause dislocations to move more readily along the previously activated deformation bands and to pile up near grain boundaries, eventually making the grain boundaries susceptible to fatigue crack initiation. The mechanisms inferred from the microstructural investigation were extremely valuable in interpreting the influence of prior monotonic straining on the subsequent fatigue life of Inconel 718 superalloy.
Montgomery, Guy H; David, Daniel; Kangas, Maria; Green, Sheryl; Sucala, Madalina; Bovbjerg, Dana H; Hallquist, Michael N; Schnur, Julie B
2014-02-20
The objective of this study was to test the efficacy of cognitive-behavioral therapy plus hypnosis (CBTH) to control fatigue in patients with breast cancer undergoing radiotherapy. We hypothesized that patients in the CBTH group receiving radiotherapy would have lower levels of fatigue than patients in an attention control group. Patients (n = 200) were randomly assigned to either the CBTH (n = 100; mean age, 55.59 years) or attention control (n = 100; mean age, 55.97 years) group. Fatigue was measured at four time points (baseline, end of radiotherapy, 4 weeks, and 6 months after radiotherapy). Fatigue was measured using the Functional Assessment of Chronic Illness Therapy (FACIT) -Fatigue subscale and Visual Analog Scales (VASs; Fatigue and Muscle Weakness). The CBTH group had significantly lower levels of fatigue (FACIT) at the end of radiotherapy (z, 6.73; P < .001), 4-week follow-up (z, 6.98; P < .001), and 6-month follow-up (z, 7.99; P < .001) assessments. Fatigue VAS scores were significantly lower in the CBTH group at the end of treatment (z, 5.81; P < .001) and at the 6-month follow-up (z, 4.56; P < .001), but not at the 4-week follow-up (P < .07). Muscle Weakness VAS scores were significantly lower in the CBTH group at the end of treatment (z, 9.30; P < .001) and at the 6-month follow-up (z, 3.10; P < .02), but not at the 4-week follow-up (P < .13). The results support CBTH as an evidence-based intervention to control fatigue in patients undergoing radiotherapy for breast cancer. CBTH is noninvasive, has no adverse effects, and its beneficial effects persist long after the last intervention session. CBTH seems to be a candidate for future dissemination and implementation.
Montgomery, Guy H.; David, Daniel; Kangas, Maria; Green, Sheryl; Sucala, Madalina; Bovbjerg, Dana H.; Hallquist, Michael N.; Schnur, Julie B.
2014-01-01
Purpose The objective of this study was to test the efficacy of cognitive-behavioral therapy plus hypnosis (CBTH) to control fatigue in patients with breast cancer undergoing radiotherapy. We hypothesized that patients in the CBTH group receiving radiotherapy would have lower levels of fatigue than patients in an attention control group. Patients and Methods Patients (n = 200) were randomly assigned to either the CBTH (n = 100; mean age, 55.59 years) or attention control (n = 100; mean age, 55.97 years) group. Fatigue was measured at four time points (baseline, end of radiotherapy, 4 weeks, and 6 months after radiotherapy). Fatigue was measured using the Functional Assessment of Chronic Illness Therapy (FACIT) –Fatigue subscale and Visual Analog Scales (VASs; Fatigue and Muscle Weakness). Results The CBTH group had significantly lower levels of fatigue (FACIT) at the end of radiotherapy (z, 6.73; P < .001), 4-week follow-up (z, 6.98; P < .001), and 6-month follow-up (z, 7.99; P < .001) assessments. Fatigue VAS scores were significantly lower in the CBTH group at the end of treatment (z, 5.81; P < .001) and at the 6-month follow-up (z, 4.56; P < .001), but not at the 4-week follow-up (P < .07). Muscle Weakness VAS scores were significantly lower in the CBTH group at the end of treatment (z, 9.30; P < .001) and at the 6-month follow-up (z, 3.10; P < .02), but not at the 4-week follow-up (P < .13). Conclusion The results support CBTH as an evidence-based intervention to control fatigue in patients undergoing radiotherapy for breast cancer. CBTH is noninvasive, has no adverse effects, and its beneficial effects persist long after the last intervention session. CBTH seems to be a candidate for future dissemination and implementation. PMID:24419112
NASA Astrophysics Data System (ADS)
Holzwarth, Uwe; Schaaff, Petra
2004-03-01
Positron-lifetime measurements have been performed on austenitic stainless steel during (i) stress- and (ii) strain-controlled fatigue experiments for different applied stress and strain amplitudes, respectively. For this purpose a generator-detector assembly with a 72Se/72As positron generator [maximum activity 25 μCi (0.9 MBq)] has been mounted on mechanical testing machines in order to measure the positron lifetime without removing the specimens from the load train. The average positron lifetime has been determined by a β+-γ coincidence. The feasibility to use the average positron lifetime for monitoring the evolution of fatigue damage and to predict early failure has been examined. In strain- and stress-controlled experiments the average positron lifetime shows a pronounced increase within the first 10% and 40% of the fatigue life, respectively. In stress-controlled experiments the average positron lifetime at failure depends significantly on the applied stress amplitude. In strain-controlled experiments significantly different positron lifetimes for different applied plastic strain amplitudes are obtained within the first 1.000 fatigue cycles, whereas differences get wiped out during further cycling until failure.
Ghahari, Setareh; Packer, Tanya
2012-01-01
To evaluate effectiveness of a face-to-face and an online fatigue self-management programme and to compare these to two control groups (information-only and no-intervention) in a sample of adults (n = 115) with neurological conditions reporting extreme fatigue. Non-equivalent pre-test post-test control group design using the Fatigue Impact Scale, Personal Wellbeing Index and Activity Card Sort as primary outcome measures. Participants in the two intervention groups and the information-only group showed clinically significant improvements in fatigue over time (p < 0.05). When compared to the no-intervention group, face-to-face participants showed significantly greater improvement in overall and cognitive fatigue, while participants in the online group showed significant improvement in self-efficacy and stress. Participation in either the online or face-to-face programme appears to result in improved self-management, however, with different potency depending on outcomes. The improvement in the online information only group further complicates the understanding of the results. With few other comparisons of online and face-to-face self-management protocols available, further research is needed to understand differential impacts which may be related to the delivery format, the rural versus urban split of participants or other unknown factors.
Measurement of fatigue following 18 msw dry chamber dives breathing air or enriched air nitrox.
Harris, R J D; Doolette, D J; Wilkinson, D C; Williams, D J
2003-01-01
Many divers report less fatigue following diving breathing oxygen rich N2-O2 mixtures compared with breathing air. In this double blinded, randomized controlled study 11 divers breathed either air or Enriched Air Nitrox 36% (oxygen 36%, nitrogen 64%) during an 18 msw (281 kPa(a)) dry chamber dive for a bottom time of 40 minutes. Two periods of exercise were performed during the dive. Divers were assessed before and after each dive using the Multidimensional Fatigue Inventory-20, a visual analogue scale, Digit Span Tests, Stroop Tests, and Divers Health Survey (DHS). Diving to 18m produced no measurable difference in fatigue, attention levels, ability to concentrate or DHS scores, following dives using either breathing gas.
Low cycle fatigue properties of type 316 stainless steel in vacuum
NASA Astrophysics Data System (ADS)
Furuya, Kazuo; Nagata, Norio; Watanabe, Ryoji
1980-04-01
Low cycle fatigue tests in vacuum were carried out on Type 316 stainless steel under the push-pull type, strain-controlled, continuous cycling mode in the temperature range from room temperature to 1073 K and strain rate from 5 × 10 -3 to 5 × 10 -5/s . Little temperature dependence of the fatigue life at a given plastic strain range is observed. The fatigue life decreases with decreasing strain rate at room temperature and 823 K, but shows little change at 973 and 1073 K. The fracture mode is transgranular in most cases, but an indication of intergranular cracking is observed in the specimens tested at 1073 K and at the lowest strain rate. The results are treated by the general adsorption model.
The Effect of Porosity on Fatigue of Die Cast AM60
NASA Astrophysics Data System (ADS)
Yang, Zhuofei; Kang, Jidong; Wilkinson, David S.
2016-07-01
AM60 high-pressure die castings are known to contain significant porosity which can affect fatigue life. We have studied this using samples drawn from prototype AM60 shock towers by conducting strain-controlled fatigue tests accompanied by X-ray computed tomography analysis. The results show that the machined surface is the preferential location for fatigue crack development, with pores close to these surfaces serving as initiation sites. Fatigue life shows a strong inverse correlation with the size of the fatigue-crack-initiating pore. Pore shape and pore orientation also influence the response. A supplemental study on surface roughness shows that porosity is the dominant factor in fatigue. Tomography enables the link between porosity and fatigue crack initiation to be clearly identified. These data are complemented by SEM observations of the fracture surfaces which are generally flat and full of randomly oriented serration patterns but without long-range fatigue striations.
NASA Astrophysics Data System (ADS)
Liu, Jia; Li, Jing; Zhang, Zhong-ping
2013-04-01
In this article, a fatigue damage parameter is proposed to assess the multiaxial fatigue lives of ductile metals based on the critical plane concept: Fatigue crack initiation is controlled by the maximum shear strain, and the other important effect in the fatigue damage process is the normal strain and stress. This fatigue damage parameter introduces a stress-correlated factor, which describes the degree of the non-proportional cyclic hardening. Besides, a three-parameter multiaxial fatigue criterion is used to correlate the fatigue lifetime of metallic materials with the proposed damage parameter. Under the uniaxial loading, this three-parameter model reduces to the recently developed Zhang's model for predicting the uniaxial fatigue crack initiation life. The accuracy and reliability of this three-parameter model are checked against the experimental data found in literature through testing six different ductile metals under various strain paths with zero/non-zero mean stress.
In-phase and out-of-phase axial-torsional fatigue behavior of Haynes 188 at 760 C
NASA Technical Reports Server (NTRS)
Kalluri, Sreeramesh; Bonacuse, Peter J.
1991-01-01
Isothermal, in-phase and out-of-phase axial-torsional fatigue experiments have been conducted at 760 C on uniform gage section, thin-walled tubular specimens of a wrought cobalt-base superalloy, Haynes 188. Test-control and data acquisition were accomplished with a minicomputer. Fatigue lives of the in- and out-of-phase axial-torsional fatigue tests have been estimated with four different multiaxial fatigue life prediction models that were developed primarly for predicting axial-torsional fatigue lives at room temperature. The models investigated were: (1) the von Mises equivalent strain range; (2) the Modified Multiaxiality Factor Approach; (3) the Modified Smith-Watson-Topper Parameter; and (4) the critical shear plane method of Fatemi, Socie, and Kurath. In general, life predictions by the von Mises equivalent strain range model were within a factor of 2 for a majority of the tests and the predictions by the Modified Multiaxiality Factor Approach were within a factor of 2, while predictions of the Modified Smith-Watson-Topper Parameter and of the critical shear plane method of Fatemi, Socie, and Kurath were unconservative and conservative, respectively, by up to factors of 4. In some of the specimens tested under combined axial-torsional loading conditions, fatigue cracks initiated near extensometer indentations. Two design modifications have been proposed to the thin-walled tubular specimen to overcome this problem.
B-52 control configured vehicles: Flight test results
NASA Technical Reports Server (NTRS)
Arnold, J. I.; Murphy, F. B.
1976-01-01
Recently completed B-52 Control Configured Vehicles (CCV) flight testing is summarized, and results are compared to analytical predictions. Results are presented for five CCV system concepts: ride control, maneuver load control, flutter mode control, augmented stability, and fatigue reduction. Test results confirm analytical predictions and show that CCV system concepts achieve performance goals when operated individually or collectively.
Hartkamp, A; Geenen, R; Bijl, M; Kruize, A; Godaert, G; Derksen, R
2004-01-01
Methods: Sixty female patients with pSS filled out a questionnaire to assess multiple dimensions of fatigue. Scores were compared with values in a population based control group (n = 139). Levels of interleukin (IL)1ß, IL2, IL6, IL10, and tumour necrosis factor α were measured in serum with commercial sandwich ELISAs. The relationship between self reported dimensions of fatigue and these serum cytokine levels was determined. Results: Patients with pSS had high scores at all dimensions of fatigue (p<0.001): general fatigue, physical fatigue, reduced activity, reduced motivation, and mental fatigue. Fatigue levels were not related to serum cytokine levels. The incidental finding that reduced motivation was higher in patients with detectable serum levels of IL10 (p = 0.04) disappeared after correction for multiple testing. Conclusion: Fatigue is prominent in patients with pSS and involves all dimensions of fatigue. The findings do not suggest a widespread effect of circulating cytokines on multiple aspects of fatigue. PMID:15361396
Creep-Fatigue Interaction Testing
NASA Technical Reports Server (NTRS)
Halford, Gary R.
2001-01-01
Fatigue fives in metals are nominally time independent below 0.5 T(sub Melt). At higher temperatures, fatigue lives are altered due to time-dependent, thermally activated creep. Conversely, creep rates are altered by super. imposed fatigue loading. Creep and fatigue generally interact synergistically to reduce material lifetime. Their interaction, therefore, is of importance to structural durability of high-temperature structures such as nuclear reactors, reusable rocket engines, gas turbine engines, terrestrial steam turbines, pressure vessel and piping components, casting dies, molds for plastics, and pollution control devices. Safety and lifecycle costs force designers to quantify these interactions. Analytical and experimental approaches to creep-fatigue began in the era following World War II. In this article experimental and life prediction approaches are reviewed for assessing creep-fatigue interactions of metallic materials. Mechanistic models are also discussed briefly.
Saxby, Dyani J; Matthews, Gerald; Warm, Joel S; Hitchcock, Edward M; Neubauer, Catherine
2013-12-01
Despite the known dangers of driver fatigue, it is a difficult construct to study empirically. Different forms of task-induced fatigue may differ in their effects on driver performance and safety. Desmond and Hancock (2001) defined active and passive fatigue states that reflect different styles of workload regulation. In 2 driving simulator studies we investigated the multidimensional subjective states and safety outcomes associated with active and passive fatigue. Wind gusts were used to induce active fatigue, and full vehicle automation to induce passive fatigue. Drive duration was independently manipulated to track the development of fatigue states over time. Participants were undergraduate students. Study 1 (N = 108) focused on subjective response and associated cognitive stress processes, while Study 2 (N = 168) tested fatigue effects on vehicle control and alertness. In both studies the 2 fatigue manipulations produced different patterns of subjective response reflecting different styles of workload regulation, appraisal, and coping. Active fatigue was associated with distress, overload, and heightened coping efforts, whereas passive fatigue corresponded to large-magnitude declines in task engagement, cognitive underload, and reduced challenge appraisal. Study 2 showed that only passive fatigue reduced alertness, operationalized as speed of braking and steering responses to an emergency event. Passive fatigue also increased crash probability, but did not affect a measure of vehicle control. Findings support theories that see fatigue as an outcome of strategies for managing workload. The distinction between active and passive fatigue is important for assessment of fatigue and for evaluating automated driving systems which may induce dangerous levels of passive fatigue. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Golan, Daniel; Doniger, Glen M; Wissemann, Karl; Zarif, Myassar; Bumstead, Barbara; Buhse, Marijean; Fafard, Lori; Lavi, Idit; Wilken, Jeffrey; Gudesblatt, Mark
2018-02-01
The association between subjective cognitive fatigue and objective cognitive dysfunction in patients with multiple sclerosis (PwMS) has been studied, with conflicting results. To explore the impact of fatigue on cognitive function, while controlling for the influence of depression, disability, comorbidities, and psychotropic medications. PwMS completed a computerized cognitive testing battery with age- and education-adjusted cognitive domain scores. Disability (Expanded Disability Status Scale (EDSS)), cognitive fatigue, and depression were concurrently evaluated. In all, 699 PwMS were included. Both cognitive fatigue and depression were significantly and negatively correlated with the same cognitive domains: information processing speed, executive function, attention, motor function, and memory (-0.15 ⩽ r ⩽ -0.14 for cognitive fatigue; -0.24 ⩽ r ⩽ -0.19 for depression). Multivariate analysis revealed significant but small independent correlations only between depression and neuropsychological test results, while cognitive fatigue had no independent correlation with objective cognitive function except for a trend toward impaired motor function in highly fatigued PwMS. Depression and cognitive fatigue accounted for no more than 6% of the variance in objective cognitive domain scores. Cognitive fatigue is not independently related to objective cognitive impairment. Depression may influence cognitive function of PwMS primarily when it is severe. Cognitive impairment in PwMS should not be ascribed to fatigue or mild depression.
DETERMINATION OF THE CREEP–FATIGUE INTERACTION DIAGRAM FOR ALLOY 617
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, J. K.; Carroll, L. J.; Sham, T. -L.
Alloy 617 is the leading candidate material for an intermediate heat exchanger for the very high temperature reactor. To evaluate the behavior of this material in the expected service conditions, creep-fatigue testing was performed. Testing has been performed primarily on a single heat of material at 850 and 950°C for total strain ranges of 0.3 to 1% and tensile hold times as long as 240 minutes. At 850°C, increases in the tensile hold duration degraded the creep fatigue resistance, at least to the investigated strain-controlled hold time of up to 60 minutes at the 0.3% strain range and 240 minutesmore » at the 1.0% strain range. At 950°C, the creep-fatigue cycles to failure becomes constant with increasing hold times, indicating saturation occurs at relatively short hold times. The creep and fatigue damage fractions have been calculated and plotted on a creep-fatigue interaction D-diagram. Results from earlier creep-fatigue tests at 800 and 1000°C on an additional heat of Alloy 617 are also plotted on the D-diagram. The methodology for calculating the damage fractions will be presented, and the effects of strain rate, strain range, temperature, hold time, and strain profile (i.e. holds in tension, compression or both) on the creep-fatigue damage will be explored.« less
Low cycle fatigue behaviour of a plasma-sprayed coating material
NASA Technical Reports Server (NTRS)
Gayda, J.; Gabb, T. P.; Miner, R. V.
1986-01-01
Single crystal nickel-base superalloys employed in turbine blade applications are often used with a plasma spray coating for oxidation and hot corrosion resistance. These coatings may also affect fatigue life of the superalloy substrate. As part of a large program to understand the fatigue behavior of coated single crystals, fully reversed, total strain controlled fatigue tests were run on a free standing NiCoCrAlY coating alloy, PWA 276, at 0.1 Hz. Fatigue tests were conducted at 650 C, where the NiCoCrAlY alloy has modest ductility, and at 1050 C, where it is extremely ductile, showing tensile elongation in excess of 100 percent. At the lower test temperature, deformation induced disordering softened the NiCoCrAlY alloy, while at the higher test temperature cyclic hardening was observed which was linked to gradual coarsening of the two phase microstructure. Fatigue life of the NiCoCrAlY alloy was significantly longer at the higher temperature. Further, the life of the NiCoCrAlY alloy exceeds that of coated, /001/-oriented PWA 1480 single crystals at 1050 C but at 650 C the life of the coated crystal is greater than that of the NiCoCrAlY alloy on a total strain basis.
The low cycle fatigue behavior of a plasma-sprayed coating material
NASA Technical Reports Server (NTRS)
Gayda, J.; Gabb, T. P.; Miner, R. V., Jr.
1986-01-01
Single crystal nickel-base superalloys employed in turbine blade applications are often used with a plasma spray coating for oxidation and hot corrosion resistance. These coatings may also affect fatigue life of the superalloy substrate. As part of a large program to understand the fatigue behavior of coated single crystals, fully reversed, total strain controlled fatigue tests were run on a free standing NiCoCrAlY coating alloy, PWA 276, at 0.1 Hz. Fatigue tests were conducted at 650 C, where the NiCoCrAlY alloy has modest ductility, and at 1050 C, where it is extremely ductile, showing tensile elongation in excess of 100 percent. At the lower test temperature, deformation induced disordering softened the NiCoCrAlY alloy, while at the higher test temperature cyclic hardening was observed which was linked to gradual coarsening of the two phase microstructure. Fatigue life of the NiCoCrAlY alloy was significantly longer at the higher temperature. Further, the life of the NiCoCrAlY alloy exceeds that of coated, /001/-oriented PWA 1480 single crystals at 1050 C, but at 650 C the life of the coated crystal is greater than that of the NiCoCrAlY alloy on a total strain basis.
Low-cycle fatigue of Fe-20%Cr alloy processed by equal- channel angular pressing
NASA Astrophysics Data System (ADS)
Kaneko, Yoshihisa; Tomita, Ryuji; Vinogradov, Alexei
2014-08-01
Low-cycle fatigue properties were investigated on Fe-20%Cr ferritic stainless steel processed by equal channel angular pressing (ECAP). The Fe-20%Cr alloy bullets were processed for one to four passes via Route-Bc. The ECAPed samples were cyclically deformed at the constant plastic strain amplitude ɛpl of 5x10-4 at room temperature in air. After the 1-pass ECAP, low-angle grain boundaries were dominantly formed. During the low-cycle fatigue test, the 1-pass sample revealed the rapid softening which continued until fatigue fracture. Fatigue life of the 1-pass sample was shorter than that of a coarse-grained sample. After the 4-pass ECAP, the average grain size reduced down to about 1.5 μm. At initial stage of the low-cycle fatigue tests, the stress amplitude increased with increasing ECAP passes. At the samples processed for more than 2 passes, the cyclic softening was relatively moderate. It was found that fatigue life of the ECAPed Fe-20%Cr alloy excepting the 1-pass sample was improved as compared to the coarse-grained sample, even under the strain controlled fatigue condition.
NASA Astrophysics Data System (ADS)
Zhang, Shuiqiang; Mao, Shuangshuang; Arola, Dwayne; Zhang, Dongsheng
2014-09-01
Characterizing the strain-life fatigue behavior of thin sheet metals is often challenging since the required specimens have short gauge lengths to avoid buckling, thereby preventing the use of conventional mechanical extensometers. To overcome this obstacle a microscopic optical imaging system has been developed to measure the strain amplitude during fatigue testing using Digital Image Correlation (DIC). A strategy for rapidly recording images is utilized to enable sequential image sampling rates of at least 10 frames per second (fps) using a general digital camera. An example of a complete strain-life fatigue test for thin sheet steel under constant displacement control is presented in which the corresponding strain within the gage section of the specimen is measured using the proposed imaging system. The precision in strain measurement is assessed and methods for improving the image sampling rates in dynamic testing are discussed.
Use of atomic force microscopy for characterizing damage evolution during fatigue
NASA Astrophysics Data System (ADS)
Cretegny, Laurent
2000-10-01
A study of the development of surface fatigue damage in PH 13-8 Mo stainless steel and copper by atomic force microscopy (AFM) was performed. AFM observations allow highly automated, quantitative characterization of surface deformation with a resolution of 5 nm or better, which is ideal for understanding fatigue damage evolution. A secondary objective was to establish a correlation between fatigue life exhausted and impedance spectroscopy. Strain controlled fatigue tests were conducted both in high and low cycle fatigue regimes, and interruptions of the fatigue tests allowed characterizing the evolution of the surface upset at various life-fractions. In the low strain amplitude tests on stainless steel (Deltaepsilonpl/2 = 0.0026%), surface damage occurred in the shape of narrow streaks at the interface between martensite laths where reverted austenite was present. The streaks eventually coalesced to form crack nuclei. In high strain amplitude tests (Deltaepsilon pl/2 = 0.049%), fatigue surface damage was essentially dominated by the formation of extrusions. In copper, both low (Deltaepsilonpl/2 = 0.061%) and high (Deltaepsilonpl/2 = 0.134%) strain amplitude tests showed the formation of slip bands (mainly extrusions) across entire grains. Protrusions were present only in copper specimens tested at the high strain amplitude. Crack nucleation in the low strain amplitude tests occurred in both materials at the interface between a region that sustained a high level of deformation and one with little evidence of surface upset. This commonality between these two materials that are otherwise very dissimilar in nature suggests a universal scheme for location of fatigue crack nucleation sites during HCF. A procedure was developed in this study to quantitatively characterize the amount of irreversible surface strain. The proposed formalism is applicable to any material, independently of the type of surface damage, and leads to a criterion for crack nucleation based on physical evidence of surface damage. A correlation between fatigue damage and impedance spectroscopy measurements was shown in copper, in particular during the primary cyclic hardening stage. The measurements were however less sensitive to the development of surface upset that occurred beyond that stage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, Julie Knibloe
2015-08-01
Alloy 617 is the leading candidate material for an intermediate heat exchanger for the very high temperature reactor. To evaluate the behavior of this material in the expected service conditions, strain controlled cyclic tests that include long hold times up to 240 minutes at maximum tensile strain were conducted at 850°C. In terms of the total number of cycles to failure, the fatigue resistance decreased when a hold time was added at peak tensile strain. Increases in the tensile hold duration degraded the creep fatigue resistance, at least to the investigated strain controlled hold time of up to 60 minutesmore » at the 0.3% strain range and 240 minutes at the 1.0% strain range. The creep fatigue deformation mode is considered relative to the lack of saturation, or continually decreasing number of cycles to failure with increasing hold times. Additionally, preliminary values from the 850°C creep fatigue data are calculated for the creep fatigue damage diagram and have higher values of creep damage than those from tests at 950°C.« less
NASA Astrophysics Data System (ADS)
Zeng, Fan Wen; Wang, Hong; Lin, Hua-Tay
2013-07-01
Lead zirconate titanate (PZT) multilayer actuators with an interdigital electrode design were studied under high electric fields (3 and 6 kV/mm) in a unipolar cycling mode. A 100 Hz sine wave was used in cycling. Five specimens tested under 6 kV/mm failed from 3.8 × 105 to 7 × 105 cycles, whereas three other specimens tested under 3 kV/mm were found to be still functional after 108 cycles. Variations in piezoelectric and dielectric responses of the tested specimens were observed during the fatigue test, depending on the measuring and cycling conditions. Selected fatigued and damaged actuators were characterized using an impedance analyzer or small signal measurement. Furthermore, involved fatigue and failure mechanisms were investigated using scanning acoustic microscope and scanning electron microscope. The extensive cracks and porous regions were revealed across the PZT layers on the cross sections of a failed actuator. The results from this study have demonstrated that the high-field cycling can accelerate the fatigue of PZT stacks as long as the partial discharge is controlled. The small signal measurement can also be integrated into the large signal measurement to characterize the fatigue response of PZT stacks in a more comprehensive basis. The former can further serve as an experimental method to test and monitor the behavior of PZT stacks.
NASA Astrophysics Data System (ADS)
Song, Di; Kang, Guozheng; Kan, Qianhua; Yu, Chao; Zhang, Chuanzeng
2015-07-01
In this work, the low-cycle fatigue failure of super-elastic NiTi shape memory alloy micro-tubes with a wall thickness of 150 μm is investigated by uniaxial stress-controlled cyclic tests at human body temperature 310 K. The effects of mean stress, peak stress, and stress amplitude on the uniaxial whole-life transformation ratchetting and fatigue failure of the NiTi alloy are observed. It is concluded that the fatigue life depends significantly on the stress levels, and the extent of martensite transformation and its reverse play an important role in determining the fatigue life. High peak stress or complete martensite transformation shortens the fatigue life.
Vargas, Sara; Antoni, Michael H; Carver, Charles S; Lechner, Suzanne C; Wohlgemuth, William; Llabre, Maria; Blomberg, Bonnie B; Glück, Stefan; DerHagopian, Robert P
2014-12-01
Sleep disruption and fatigue are ubiquitous among cancer patients and are sources of stress that may compromise treatment outcomes. Previously, we showed that a cognitive behavioral stress management (CBSM) intervention reduced anxiety and other stress-related processes in women undergoing primary treatment for breast cancer. This study examined secondary outcomes from a CBSM intervention trial for women with early-stage breast cancer to test if CBSM would improve sleep quality and fatigue among these patients at a single site in southern Florida. CBSM-related effects have already been demonstrated for indicators of psychosocial adaptation (e.g., general and cancer-related anxiety). Patients were randomized to CBSM (n= 120) or a 1-day psychoeducation control group (n= 120). The Pittsburgh Sleep Quality Index (PSQI) and Fatigue Symptom Inventory were completed prior to randomization and 6 and 12 months after the baseline assignment. In latent growth analyses, women in CBSM reported greater improvements in PSQI sleep quality scores than controls, although there were no significant differences between conditions on PSQI total scores. Women in CBSM also reported greater reductions in fatigue-related daytime interference than controls, though there were no significant differences in changes in fatigue intensity. Changes in sleep quality were associated with changes in fatigue. Future work may consider integrating sleep and fatigue content into stress management interventions for women with early-stage breast cancer.
Scatter of fatigue data owing to material microscopic effects
NASA Astrophysics Data System (ADS)
Tang, XueSong
2014-01-01
A common phenomenon of fatigue test data reported in the open literature such as S-N curves exhibits the scatter of points for a group of same specimens under the same loading condition. The reason is well known that the microstructure is different from specimen to specimen even in the same group. Specifically, a fatigue failure process is a multi-scale problem so that a fatigue failure model should have the ability to take the microscopic effect into account. A physically-based trans-scale crack model is established and the analytical solution is obtained by coupling the micro- and macro-scale. Obtained is the trans-scale stress intensity factor as well as the trans-scale strain energy density (SED) factor. By taking this trans-scale SEDF as a key controlling parameter for the fatigue crack propagation from micro- to macro-scale, a trans-scale fatigue crack growth model is proposed in this work which can reflect the microscopic effect and scale transition in a fatigue process. The fatigue test data of aluminum alloy LY12 plate specimens is chosen to check the model. Two S-N experimental curves for cyclic stress ratio R=0.02 and R=0.6 are selected. The scattering test data points and two S-N curves for both R=0.02 and R=0.6 are exactly re-produced by application of the proposed model. It is demonstrated that the proposed model is able to reflect the multiscaling effect in a fatigue process. The result also shows that the microscopic effect has a pronounced influence on the fatigue life of specimens.
NASA Technical Reports Server (NTRS)
Barrie, Robert L.; Gabb, Timothy P.; Telesman, Jack; Kantzos, Peter T.; Prescenzi, Anthony; Biles, T.; Bonacuse, P. J.
2006-01-01
The fatigue lives of modern powder metallurgy disk alloys can be reduced over an order of magnitude by cracking at inherent non-metallic inclusions. The objective of this work was to study the effectiveness of shot peening in suppressing LCF crack initiation and growth at surface nonmetallic inclusions. Inclusions were carefully introduced at elevated levels during powder metallurgy processing of the nickel-base disk superalloy Udimet 720. Multiple strain-controlled fatigue tests were then performed on machined specimens with and without shot peened test sections at 427 C and 650 C. The low cycle fatigue lives and failure initiation sites varied as functions of inclusion content, shot peening, and fatigue conditions. A large majority of the failures in as-machined specimens with the introduced inclusions occurred at cracks initiating from inclusions intersecting the specimen surface. These inclusions reduced fatigue life by up to 100X, when compared to lives of material without inclusions residing at specimen surface. Large inclusions produced the greatest reductions in life for tests at low strain ranges and high strain ratios. Shot peening improved life in many cases by reducing the most severe effects of inclusions.
Results of inphase axial-torsional fatigue experiments on 304 stainless steel
NASA Technical Reports Server (NTRS)
Bonacuse, Peter J.; Kalluri, Sreeramesh
1989-01-01
A series of axial-torsional, inphase, strain-controlled, low-cycle fatigue tests were performed at room temperature on tubular specimens of 304 stainless steel. The program was conducted in cooperation with the task group on multiaxial fatigue research of ASTM committee E-09. The objective was to quantify the variability in multiaxial test results among several laboratories. Only included is data which was generated at the NASA Lewis Research Center's High Temperature Fatigue and Structures Laboratory. The experimental equipment and procedures used are described. The tubular specimens were polished on the outer surface to aid in the use of a cellulose film surface replication technique for crack detection. However, cracking initiated predominantly on the internal surface for all specimens. Honing of the bore of the tubular specimens lessened but did not entirely eliminate this problem. The observed fatigue lives are compared with lives calculated from three multiaxial life models. Constants for the life prediction models were obtained from uniaxial and torsional tests performed on the same heat of material. The observed fatigue lives agreed with calculated lives to within a factor of two for all but one of the life prediction models.
Persistent Fatigue in Hematopoietic Stem Cell Transplantation Survivors
Hacker, Eileen Danaher; Fink, Anne M.; Peters, Tara; Park, Chang; Fantuzzi, Giamila; Rondelli, Damiano
2016-01-01
Background Fatigue is highly prevalent following hematopoietic stem cell transplantation (HCT). It has been described as intense and may last for years following treatment. Objective to compare fatigue, physical activity, sleep, emotional distress, cognitive function, and biological measures in HCT survivors with persistent fatigue (n = 25) to age- and gender-matched healthy controls with occasional tiredness (n = 25). Methods Data were collected using: (a) objective, real-time assessments of physical activity and sleep over 7 days; (b) patient-reported fatigue assessments; (c) computerized objective testing of cognitive functioning; and (d) biological measures. Differences between groups were examined using MANOVA. Results HCT survivors reported increased physical (p < .001), mental (p <.001), and overall fatigue (p < .001) as well as increased anxiety (p < .05) and depression (p < .01) compared to healthy controls. Red blood cell (RBC) levels were significantly lower in HCT survivors (p < .001). RBC levels for both groups, however, were in the normal range. TNF-α (p < .001) and IL-6 (p < .05) were significantly higher in HCT survivors. Conclusions Persistent fatigue in HCT survivors compared to healthy controls with occasional tiredness is accompanied by increased anxiety and depression along with decreased RBCs. Elevated TNF-α and IL-6 may be important biomarkers. Implications for Practice This study provides preliminary support for the conceptualization of fatigue as existing on a continuum, with tiredness anchoring one end and exhaustion the other. Persistent fatigue experienced by HCT survivors is more severe than the occasional tiredness of everyday life. PMID:27333126
Koopman, Fieke S; Brehm, Merel A; Beelen, Anita; Voet, Nicole; Bleijenberg, Gijs; Geurts, Alexander; Nollet, Frans
2017-07-07
Cognitive behavioural therapy does not reduce fatigue in post-polio syndrome, but is effective in facioscapulohumeral dystrophy. This difference in efficacy might be explained by a different role of cognitions in these conditions. To compare fatigue-related cognitions between patients with post-polio syndrome and facio-scapulohumeral dystrophy. Patients with post-polio syndrome (n = 21) and facioscapulohumeral dystrophy (n = 24) allocated to a cognitive behavioural therapy intervention in 2 identical trials. Assessed cognitions included: sense of control over fatigue; catastrophizing; acceptance; focusing on fatigue; and perceived social support. Group differences in cognitions (independent t-tests or Mann-Whitney U tests) and group differences in the association of cognitions with fatigue (linear regression models) were studied. No differences in cognitions were found between the 2 groups (p > 0.18). Furthermore, there were no cognition-by-group interaction effects, except for "perceived social support", for which a different association with fatigue was found between the 2 groups (p = 0.01). However, univariate models revealed no associations per group. Fatigue-related cognitions in severely fatigued patients with post-polio syndrome are not clearly different from that in facioscapulohumeral dystrophy. Thus, the lack of efficacy of cognitive behavioural therapy in post-polio syndrome cannot be attributed to unique cognitive characteristics of this population.
High Load Ratio Fatigue Strength and Mean Stress Evolution of Quenched and Tempered 42CrMo4 Steel
NASA Astrophysics Data System (ADS)
Bertini, Leonardo; Le Bone, Luca; Santus, Ciro; Chiesi, Francesco; Tognarelli, Leonardo
2017-08-01
The fatigue strength at a high number of cycles with initial elastic-plastic behavior was experimentally investigated on quenched and tempered 42CrMo4 steel. Fatigue tests on unnotched specimens were performed both under load and strain controls, by imposing various levels of amplitude and with several high load ratios. Different ratcheting and relaxation trends, with significant effects on fatigue, are observed and discussed, and then reported in the Haigh diagram, highlighting a clear correlation with the Smith-Watson-Topper model. High load ratio tests were also conducted on notched specimens with C (blunt) and V (sharp) geometries. A Chaboche model with three parameter couples was proposed by fitting plain specimen cyclic and relaxation tests, and then finite element analyses were performed to simulate the notched specimen test results. A significant stress relaxation at the notch root became clearly evident by reporting the numerical results in the Haigh diagram, thus explaining the low mean stress sensitivity of the notched specimens.
Gupta, Arun; Kumar, Satyendra; Rajput, Rashmi; Srivastava, Ruchi; Rai, Rajiv K.; Sastry, J. L. N.
2015-01-01
Context: Traditional medicines have been considered as important resources for postponing fatigue, accelerating elimination of fatigue related metabolites and improving physical ability. Rasāyanās or rejuvenative therapies are mentioned as one of the eight clinical specialties in Ayurveda for attaining longevity, healthy life and regulation of bodily balance. Eventhough more detailed studies are needed to confirm the claims of benefits in the light of evidence based research, Ratnaprash, a herbo-mineral rasāyana formulation, is proposed here to be an antifatigue supplement that is good in promoting strength and stamina. Materials and Methods: In the present study, anti fatigue, strength and stamina enhancing properties of Ratnaprash were examined based on swim endurance capacity and the change in biochemical parameters in Swiss Albino mice. Treatment groups were orally administered Ratnaprash at various test doses (500, 1000, 2000 mg/Kg per day), while the control group received distilled water at similar dose volumes. Effect of therapy was evaluated after 28 days of treatment. Results: At the end of study period, the swimming times to exhaustion were longer in the treated groups than in the control group. Plasma lactate levels of treated groups were lower than those of the control group (P < 0.05) while tissue ATP levels were higher. These effects were dose dependent and the strongest effect was seen in groups treated at 1000 mg/Kg. Conclusion: Ratnaprash enhanced the forced swimming capacity of mice and exhibited elevated anti-fatigue activity, reduced blood lactate levels and increased tissue ATP levels in preclinical models in comparison to vehicle control, exhibiting possible role in increasing strength and stamina and contributing anti-fatigue activity. PMID:26600664
Gupta, Arun; Kumar, Satyendra; Rajput, Rashmi; Srivastava, Ruchi; Rai, Rajiv K; Sastry, J L N
2015-01-01
Traditional medicines have been considered as important resources for postponing fatigue, accelerating elimination of fatigue related metabolites and improving physical ability. Rasāyanās or rejuvenative therapies are mentioned as one of the eight clinical specialties in Ayurveda for attaining longevity, healthy life and regulation of bodily balance. Eventhough more detailed studies are needed to confirm the claims of benefits in the light of evidence based research, Ratnaprash, a herbo-mineral rasāyana formulation, is proposed here to be an antifatigue supplement that is good in promoting strength and stamina. In the present study, anti fatigue, strength and stamina enhancing properties of Ratnaprash were examined based on swim endurance capacity and the change in biochemical parameters in Swiss Albino mice. Treatment groups were orally administered Ratnaprash at various test doses (500, 1000, 2000 mg/Kg per day), while the control group received distilled water at similar dose volumes. Effect of therapy was evaluated after 28 days of treatment. At the end of study period, the swimming times to exhaustion were longer in the treated groups than in the control group. Plasma lactate levels of treated groups were lower than those of the control group (P < 0.05) while tissue ATP levels were higher. These effects were dose dependent and the strongest effect was seen in groups treated at 1000 mg/Kg. Ratnaprash enhanced the forced swimming capacity of mice and exhibited elevated anti-fatigue activity, reduced blood lactate levels and increased tissue ATP levels in preclinical models in comparison to vehicle control, exhibiting possible role in increasing strength and stamina and contributing anti-fatigue activity.
NASA Technical Reports Server (NTRS)
Smith, Robert W.; Smith, Gordon T.
1960-01-01
Thermal-fatigue crack-growth characteristics of notched- and unnotched-disk specimens of A-286, Discaloy, hot-cold worked 16-25-6, and overaged 16-25-6 were experimentally studied. Separately controlled variables were total strain range (0.0043 to 0.0079 in./in.), maximum cycle temperature (1300 and 1100 F), and hold time at maximum temperature (O and 5 min). A limited number of mechanical, push-pull, constant-strain cycle tests at room temperature were made using notched and un-notched bars of the same materials. In these tests the number of cycles to failure as well as the variation of load change with accumulated cycles was measured, and the effects of mean stress were observed. Constant-strain-range mechanical-fatigue tests at room temperature revealed notched-bar fatigue life to be strongly influenced by mean stress. For a specific strain range, the longest fatigue life was always found to be associated with the least-tensile (or most compressive) mean stress. By defining thermal-fatigue life as the number of cycles required to produce a crack area of 6000 square mils, the relative thermal-fatigue resistances of the test materials were established. Notched-disk specimens of A-286 and Discaloy steels exhibited longer fatigue lives than either hot-cold worked or overaged 16-25-6. On the other hand, unnotched-disk specimens of Discaloy and hot-cold worked 16-25-6 had longer lives than A-286 and overaged 16-25-6. Separation of the crack-growth data into microstage and macrostage periods revealed that the macrostage period accounted for the greatest part of the difference among materials when tested in the notched configuration, while the microstage was largely responsible for the differences encountered in unnotched disks.
Long-Term Muscle Fatigue After Standing Work.
Garcia, Maria-Gabriela; Läubli, Thomas; Martin, Bernard J
2015-11-01
The aims of this study were to determine long-term fatigue effects in the lower limbs associated with standing work and to estimate possible age and gender influences. The progressive accumulation of muscle fatigue effects is assumed to lead to musculoskeletal disorders, as fatigue generated by sustained low-level exertions exhibits long-lasting effects. However, these effects have received little attention in the lower limbs. Fourteen men and 12 women from two different age groups simulated standing work for 5 hr including 5-min seated rest breaks and a 30-min lunch. The younger group was also tested in a control day. Muscle fatigue was quantified by electrically induced muscle twitches (muscle twitch force [MTF]), postural stability, and subjective evaluation of discomfort. MTF showed a significant fatigue effect after standing work that persisted beyond 30 min after the end of the workday. MTF was not affected on the control day. The center of pressure displacement speed increased significantly over time after standing work but was also affected on the control day. Subjective evaluations of discomfort indicated a significant increase in perception of fatigue immediately after the end of standing work; however, this perception did not persist 30 min after. Age and gender did not influence fatigue. Objective measures show the long-term effects of muscle fatigue after 5 hr of standing work; however, this fatigue is no longer perceived after 30 min of rest postwork. The present results suggest that occupational activities requiring prolonged standing are likely to contribute to lower-extremity and/or back disorders. © 2015, Human Factors and Ergonomics Society.
Sensing sheets based on large area electronics for fatigue crack detection
NASA Astrophysics Data System (ADS)
Yao, Yao; Glisic, Branko
2015-03-01
Reliable early-stage damage detection requires continuous structural health monitoring (SHM) over large areas of structure, and with high spatial resolution of sensors. This paper presents the development stage of prototype strain sensing sheets based on Large Area Electronics (LAE), in which thin-film strain gauges and control circuits are integrated on the flexible electronics and deposited on a polyimide sheet that can cover large areas. These sensing sheets were applied for fatigue crack detection on small-scale steel plates. Two types of sensing-sheet interconnects were designed and manufactured, and dense arrays of strain gauge sensors were assembled onto the interconnects. In total, four (two for each design type) strain sensing sheets were created and tested, which were sensitive to strain at virtually every point over the whole sensing sheet area. The sensing sheets were bonded to small-scale steel plates, which had a notch on the boundary so that fatigue cracks could be generated under cyclic loading. The fatigue tests were carried out at the Carleton Laboratory of Columbia University, and the steel plates were attached through a fixture to the loading machine that applied cyclic fatigue load. Fatigue cracks then occurred and propagated across the steel plates, leading to the failure of these test samples. The strain sensor that was close to the notch successfully detected the initialization of fatigue crack and localized the damage on the plate. The strain sensor that was away from the crack successfully detected the propagation of fatigue crack based on the time history of measured strain. Overall, the results of the fatigue tests validated general principles of the strain sensing sheets for crack detection.
Zwambag, Derek P; Freeman, Nikole E; Brown, Stephen H M
2015-04-01
Sudden loads, originating at either the hands or the feet, can cause injury to spine structures. As muscles are primarily responsible for stabilization following a perturbation, the effect of spine muscle fatigue in this context has been well investigated. However, the effect of fatigue of arm muscles, which can help control perturbations originating at the hands, on the spine is unknown. The purpose of this study was to determine if the magnitude of spine flexion or the pre-activation, reflex amplitude, and reflex latency of spine muscles were altered by elbow flexor fatigue during a sudden loading (6.8 kg) perturbation at the hands. Elbow flexor fatigue was induced by an isometric 30% maximal elbow flexion moment until failure. Results demonstrate that spine kinematics were not altered in the presence of elbow flexor fatigue. Small magnitude differences in trunk muscle pre- and peak activation indicate that the presence of elbow flexor fatigue does not necessitate substantially greater spine muscle action under the tested conditions. Despite fatigued elbow flexors, the arm muscles were sufficiently able to control the perturbation. Interestingly, 5/14 participants demonstrated altered reflex latencies in all observed muscles that lasted up to 10 min after the fatiguing task. Copyright © 2015 Elsevier Ltd. All rights reserved.
Bi-axial Vibration Energy Harvesting
2012-07-01
included early dedicated portable signal averaging equipment, Nomad, CT4 and F18 fatigue test control systems and some field trials. Currently he is...and repairs to acoustically- fatigued structures. ____________________ ________________________________________________ UNCLASSIFIED...Physicists at the Tokyo Institute of Technology investigated various piezoceramic materials [20], developing lead zirconate titanate ( PZT ) in around 1952
Evoked EMG-based torque prediction under muscle fatigue in implanted neural stimulation
NASA Astrophysics Data System (ADS)
Hayashibe, Mitsuhiro; Zhang, Qin; Guiraud, David; Fattal, Charles
2011-10-01
In patients with complete spinal cord injury, fatigue occurs rapidly and there is no proprioceptive feedback regarding the current muscle condition. Therefore, it is essential to monitor the muscle state and assess the expected muscle response to improve the current FES system toward adaptive force/torque control in the presence of muscle fatigue. Our team implanted neural and epimysial electrodes in a complete paraplegic patient in 1999. We carried out a case study, in the specific case of implanted stimulation, in order to verify the corresponding torque prediction based on stimulus evoked EMG (eEMG) when muscle fatigue is occurring during electrical stimulation. Indeed, in implanted stimulation, the relationship between stimulation parameters and output torques is more stable than external stimulation in which the electrode location strongly affects the quality of the recruitment. Thus, the assumption that changes in the stimulation-torque relationship would be mainly due to muscle fatigue can be made reasonably. The eEMG was proved to be correlated to the generated torque during the continuous stimulation while the frequency of eEMG also decreased during fatigue. The median frequency showed a similar variation trend to the mean absolute value of eEMG. Torque prediction during fatigue-inducing tests was performed based on eEMG in model cross-validation where the model was identified using recruitment test data. The torque prediction, apart from the potentiation period, showed acceptable tracking performances that would enable us to perform adaptive closed-loop control through implanted neural stimulation in the future.
Feys, Peter; Moumdjian, Lousin; Van Halewyck, Florian; Wens, Inez; Eijnde, Bert O; Van Wijmeersch, Bart; Popescu, Veronica; Van Asch, Paul
2017-11-01
Exercise therapy studies in persons with multiple sclerosis (pwMS) primarily focused on motor outcomes in mid disease stage, while cognitive function and neural correlates were only limitedly addressed. This pragmatic randomized controlled study investigated the effects of a remotely supervised community-located "start-to-run" program on physical and cognitive function, fatigue, quality of life, brain volume, and connectivity. In all, 42 pwMS were randomized to either experimental (EXP) or waiting list control (WLC) group. The EXP group received individualized training instructions during 12 weeks (3×/week), to be performed in their community aiming to participate in a running event. Measures were physical (VO 2max , sit-to-stand test, Six-Minute Walk Test (6MWT), Multiple Sclerosis Walking Scale-12 (MSWS-12)) and cognitive function (Rao's Brief Repeatable Battery (BRB), Paced Auditory Serial Attention Test (PASAT)), fatigue (Fatigue Scale for Motor and Cognitive Function (FSMC)), quality of life (Multiple Sclerosis Impact Scale-29 (MSIS-29)), and imaging. Brain volumes and diffusion tensor imaging (DTI) were quantified using FSL-SIENA/FIRST and FSL-TBSS. In all, 35 pwMS completed the trial. Interaction effects in favor of the EXP group were found for VO 2max , sit-to-stand test, MSWS-12, Spatial Recall Test, FSMC, MSIS-29, and pallidum volume. VO 2max improved by 1.5 mL/kg/min, MSWS-12 by 4, FSMC by 11, and MSIS-29 by 14 points. The Spatial Recall Test improved by more than 10%. Community-located run training improved aerobic capacity, functional mobility, visuospatial memory, fatigue, and quality of life and pallidum volume in pwMS.
NASA Astrophysics Data System (ADS)
Jost, Benjamin; Klein, Marcus; Eifler, Dietmar
This paper focuses on the ductile cast iron EN-GJS-600 which is often used for components of combustion engines. Under service conditions, those components are mechanically loaded at different temperatures. Therefore, this investigation targets at the fatigue behavior of EN-GJS-600 at ambient and elevated temperatures. Light and scanning electron microscopic investigations were done to characterize the sphericity of the graphite as well as the ferrite, pearlite and graphite fraction. At elevated temperatures, the consideration of dynamic strain ageing effects is of major importance. In total strain increase, temperature increase and constant total strain amplitude tests, the plastic strain amplitude, the stress amplitude, the change in temperature and the change in electrical resistance were measured. The measured values depend on plastic deformation processes in the bulk of the specimens and at the interfaces between matrix and graphite. The fatigue behavior of EN-GJS-600 is dominated by cyclic hardening processes. The physically based fatigue life calculation "PHYBALSIT" (SIT = strain increase test) was developed for total strain controlled fatigue tests. Only one temperature increase test is necessary to determine the temperature interval of pronounced dynamic strain ageing effects.
BULEM, Üreyen Kaya; KECECI, Ayse Diljin; GULDAS, Hilmi Egemen
2013-01-01
NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. Objective To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). Material and Methods The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). Results Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexmaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). Conclusions Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance. PMID:24473715
Sacco, Rosaria; Bussman, Rita; Oesch, Peter; Kesselring, Jürg; Beer, Serafin
2011-05-01
Gait impairment and fatigue are common and disabling problems in multiple sclerosis (MS). Characterisation of abnormal gait in MS patients has been done mainly using observational studies and simple walking tests providing only limited quantitative and no qualitative data, or using intricate and time-consuming assessment procedures. In addition, the correlation of gait impairments with fatigue is largely unknown. The aim of this study was to characterise spatio-temporal gait parameters by a simple and easy-to-use gait analysis system (GAITRite®) in MS patients compared with healthy controls, and to analyse changes and correlation with fatigue during inpatient rehabilitation. Twenty-four MS patients (EDSS <6.5) admitted for inpatient rehabilitation and 19 healthy subjects were evaluated using the GAITRite® Functional Ambulation System. Between-group differences and changes of gait parameters during inpatient rehabilitation were analysed, and correlation with fatigue, using the Wurzburg Fatigue Inventory for Multiple Sclerosis (WEIMuS), was determined. Compared to healthy controls MS patients showed significant impairments in different spatio-temporal gait parameters, which showed a significant improvement during inpatient rehabilitation. Different gait parameters were correlated with fatigue physical score, and change of gait parameters was correlated with improvement of fatigue. Spatio-temporal gait analysis is helpful to assess specific walking impairments in MS patients and subtle changes during rehabilitation. Correlation with fatigue may indicate a possible negative impact of fatigue on rehabilitation outcome.
Ishii, Akira; Tanaka, Masaaki; Watanabe, Yasuyoshi
2014-01-01
Adequate rest is essential to avoid fatigue and disruption of homeostasis. However, the neural mechanisms underlying the decision to rest are not well understood. In the present study, we aimed to clarify the neural mechanisms of this decision-making process using magnetoencephalography. Fifteen healthy volunteers participated in decision and control experiments performed in a cross-over fashion. In the decision experiment, participants performed 1,200 reverse Stroop test trials and were intermittently asked to decide whether they wanted to take a rest or continue. In the control experiments, participants performed 1,200 reverse Stroop test trials and were instructed to press a response button intermittently without making any decision. Changes in oscillatory brain activity were assessed using a narrow-band adaptive spatial filtering method. The levels of decrease in theta (4–8 Hz) band power in left Brodmann's area (BA) 31, alpha (8–13 Hz) band power in left BA 10 and BA 9, and beta (13–25 Hz) band power in right BA 46 and left BA 10 were greater in trials when the participant opted to rest (rest trials) than those in control trials. The decrease in theta band power in BA 31 in the rest trials was positively correlated with the subjective level of fatigue after the decision experiment. These results demonstrated that the dorsolateral prefrontal cortex, frontal pole, and posterior cingulate cortex play a role in the decision to rest in the presence of fatigue. These findings may help clarify the neural mechanisms underlying fatigue and fatigue-related problems. PMID:25303465
Foil system fatigue load environments for commercial hydrofoil operation
NASA Technical Reports Server (NTRS)
Graves, D. L.
1979-01-01
The hydrofoil fatigue loads environment in the open sea is examined. The random nature of wave orbital velocities, periods and heights plus boat heading, speed and control system design are considered in the assessment of structural fatigue requirements. Major nonlinear load events such as hull slamming and foil unwetting are included in the fatigue environment. Full scale rough water load tests, field experience plus analytical loads work on the model 929 Jetfoil commercial hydrofoil are discussed. The problem of developing an overall sea environment for design is defined. State of the art analytical approaches are examined.
Evaluation of the cyclic behavior of aircraft turbine disk alloys
NASA Technical Reports Server (NTRS)
Cowles, B. A.; Sims, D. L.; Warren, J. R.
1978-01-01
Five aircraft turbine disk alloys representing various strength and processing histories were evaluated at 650 C to determine if recent strength advances in powder metallurgy have resulted in corresponding increases in low cycle fatigue (LCF) capability. Controlled strain LCF tests and controlled load crack propagation tests were performed. Results were used for direct material comparisons and in the analysis of an advanced aircraft turbine disk, having a fixed design and operating cycle. Crack initiation lives were found to increase with increasing tensile yield strength, while resistance to fatigue crack propagation generally decreased with increasing strength.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, Subhasish; Barua, Bipul; Listwan, Joseph
In financial year 2017, we are focusing on developing a mechanistic fatigue model of surge line pipes for pressurized water reactors (PWRs). To that end, we plan to perform the following tasks: (1) conduct stress- and strain-controlled fatigue testing of surge-line base metal such as 316 stainless steel (SS) under constant, variable, and random fatigue loading, (2) develop cyclic plasticity material models of 316 SS, (3) develop one-dimensional (1D) analytical or closed-form model to validate the material models and to understand the mechanics associated with 316 SS cyclic hardening and/or softening, (4) develop three-dimensional (3D) finite element (FE) models withmore » implementation of evolutionary cyclic plasticity, and (5) develop computational fluid dynamics (CFD) model for thermal stratification, thermal-mechanical stress, and fatigue of example reactor components, such as a PWR surge line under plant heat-up, cool-down, and normal operation with/without grid-load-following. This semi-annual progress report presents the work completed on the above tasks for a 316 SS laboratory-scale specimen subjected to strain-controlled cyclic loading with constant, variable, and random amplitude. This is the first time that the accurate 3D-FE modeling of the specimen for its entire fatigue life, including the hardening and softening behavior, has been achieved. We anticipate that this work will pave the way for the development of a fully mechanistic-computer model that can be used for fatigue evaluation of safety-critical metallic components, which are traditionally evaluated by heavy reliance on time-consuming and costly test-based approaches. This basic research will not only help the nuclear reactor industry for fatigue evaluation of reactor components in a cost effective and less time-consuming way, but will also help other safety-related industries, such as aerospace, which is heavily dependent on test-based approaches, where a single full-scale fatigue test can cost millions of dollars and require years of effort to conduct. Toward our goal of demonstration of fully mechanistic fatigue evaluation of reactor components, we also started work on developing a component-level computer model of reactor components, such as 316 SS surge line pipe. This requires developing a thermal-mechanical stress analysis model of the reactor surge line, which, in turn, requires time-dependent temperature and stratification information along the boundary of the pipe. Toward that goal, CFD models of surge lines are being developed. In this report, we also present some preliminary results showing the temperature conditions along the surge line wall under reactor heat-up, cool-down, and steady-state power operation.« less
Creep-Fatigue Interaction and Cyclic Strain Analysis in P92 Steel Based on Test
NASA Astrophysics Data System (ADS)
Ji, Dongmei; Zhang, Lai-Chang; Ren, Jianxing; Wang, Dexian
2015-04-01
This work focused on the interaction of creep and fatigue and cyclic strain analysis in high-chromium ferritic P92 steel based on load-controlled creep-fatigue (CF) tests and conventional creep test at 873 K. Mechanical testing shows that the cyclic load inhibits the propagation of creep damage in the P92 steel and CF interaction becomes more severe with the decrease in the holding period duration and stress ratio. These results are also verified by the analysis of cyclic strain. The fatigue lifetime reduces with the increasing of the holding period duration and it does not reduce much with the increasing stress ratio especially under the conditions of long holding period duration. The cyclic strains (i.e., the strain range and creep strain) of CF tests consist of three stages, which is the same as those for the conventional creep behavior. The microscopic fracture surface observations illustrated that two different kinds of voids are observed at the fracture surfaces and Laves phase precipitates at the bottom of the voids.
Neil, Sarah E; Klika, Riggs J; Garland, S Jayne; McKenzie, Donald C; Campbell, Kristin L
2013-03-01
Fatigue is one of the most commonly reported side effects during treatment for breast cancer and can persist following treatment completion. Cancer-related fatigue after treatment is multifactorial in nature, and one hypothesized mechanism is cardiorespiratory and neuromuscular deconditioning. The purpose of this study was to compare cardiorespiratory and neuromuscular function in breast cancer survivors who had completed treatment and met the specified criteria for cancer-related fatigue and a control group of breast cancer survivors without fatigue. Participants in the fatigue (n = 16) and control group (n = 11) performed a maximal exercise test on a cycle ergometer for determination of peak power, power at lactate threshold, and VO(2) peak. Neuromuscular fatigue was induced with a sustained submaximal contraction of the right quadriceps. Central fatigue (failure of voluntary activation) was evaluated using twitch interpolation, and peripheral fatigue was measured with an electrically evoked twitch. Power at lactate threshold was lower in the fatigue group (p = 0.05). There were no differences between groups for power at lactate threshold as percentage of peak power (p = 0.10) or absolute or relative VO(2) peak (p = 0.08 and 0.33, respectively). When adjusted for age, the fatigue group had a lower power at lactate threshold (p = 0.02) and absolute VO(2) peak (p = 0.03). There were no differences between groups in change in any neuromuscular parameters after the muscle-fatiguing protocol. Findings support the hypothesis that cardiorespiratory deconditioning may play a role in the development and persistence of cancer-related fatigue following treatment. Future research into the use of exercise training to reduce cardiorespiratory deconditioning as a treatment for cancer-related fatigue is warranted to confirm these preliminary findings.
Kwekkeboom, Kristine L; Bratzke, Lisa C
2016-01-01
Pain, dyspnea, fatigue, and sleep disturbance are prevalent and distressing symptoms in persons with advanced heart failure. Although many lifestyle and self-care interventions have been developed to control heart failure progression, very few studies have explored treatments exclusively for symptom palliation. Cognitive-behavioral strategies may be effective treatment for these symptoms in advanced heart failure. A systemic review was conducted to describe the effect of cognitive-behavioral strategies on pain, dyspnea, fatigue, and sleep disturbance in patients with heart failure. CINAHL, Medline, and PsychINFO were searched from inception through December 2014. Articles were selected for inclusion if they tested a cognitive-behavioral strategy using a quasi-experimental or experimental design, involved a sample of adults with heart failure, and measured pain, dyspnea, fatigue, sleep disturbance, or symptom-related quality of life. The 2 authors evaluated study quality, abstracted data elements from each study, and synthesized findings. Thirteen articles describing 9 unique studies met criteria and were included in the review. Five studies tested relaxation strategies, 3 tested meditation strategies, and 1 tested a guided imagery strategy. Of the 9 studies, 7 demonstrated some improvement in symptom outcomes. Relaxation, meditation, guided imagery, or combinations of these strategies resulted in less dyspnea and better sleep compared with attention control or usual care conditions and reduced pain, dyspnea, fatigue, and sleep disturbance within treatment groups (pretreatment to posttreatment). Symptom-related quality of life was improved with meditation compared with attention control and usual care conditions and improved pre- to post-guided imagery. Studies exploring cognitive-behavioral symptom management strategies in heart failure vary in quality and report mixed findings but indicate potential beneficial effects of relaxation, meditation, and guided imagery on heart failure-related symptoms. Future research should test cognitive-behavioral strategies in rigorously designed efficacy trials, using samples selected for their symptom experience, and measure pain, dyspnea, fatigue, and sleep disturbance outcomes with targeted symptom measures.
Kwekkeboom, Kristine L.; Bratzke, Lisa C.
2015-01-01
Background Pain, dyspnea, fatigue, and sleep disturbance are prevalent and distressing symptoms in persons with advanced heart failure. Although many lifestyle and self-care interventions have been developed to control heart failure progression, very few studies have explored treatments exclusively for symptom palliation. Cognitive-behavioral strategies may be effective treatment for these symptoms in advanced heart failure. Objective A systemic review was conducted to describe the effect of cognitive-behavioral strategies on pain, dyspnea, fatigue, and sleep disturbance in patients with heart failure. Methods CINAHL, Medline, and PsychINFO were searched from inception through December 2014. Articles were selected for inclusion if they tested a cognitive-behavioral strategy using a quasi-experimental or experimental design, involved a sample of adults with heart failure, and measured pain, dyspnea, fatigue, sleep disturbance, or symptom-related quality of life (QoL). The two authors evaluated study quality, abstracted data elements from each study, and synthesized findings. Results Thirteen articles describing nine unique studies met criteria and were included in the review. Five studies tested relaxation strategies, three tested meditation strategies, and one tested a guided imagery strategy. Seven of the nine studies demonstrated some improvement in symptom outcomes. Relaxation, meditation, guided imagery, or combinations of these strategies resulted in less dyspnea and better sleep compared to attention control or usual care conditions, and reduced pain, dyspnea, fatigue and sleep disturbance within treatment groups (pre- to post-treatment). Symptom-related QoL was improved with meditation compared to attention control and usual care conditions, and improved pre- to post-guided imagery. Conclusions Studies exploring cognitive-behavioral symptom management strategies in heart failure vary in quality and report mixed findings, but indicate potential beneficial effects of relaxation, meditation, and guided imagery on heart failure-related symptoms. Future research should test cognitive-behavioral strategies in rigorously designed efficacy trials, using samples selected for their symptom experience, and measure pain, dyspnea, fatigue, and sleep disturbance outcomes with targeted symptom measures. PMID:26065388
Mechanical Properties of Ceramics for High Temperature Applications
1976-12-01
difficult so far. Also torsion creep tests have been performed /2 /, not considered in this figure. The data show a relatively consistent picture...mittent creep test. Corrosion effects are claimed to be operative during fatigue : The lifetime of a fa- tigue specimen, being controlled by the slow...of plot at extremely low rates of loading. The static fatigue limit on this type of plot is the strength below which there is no effect of loading
Thermomechanical fatigue behavior of SiC/Ti-24Al-11Nb in air and argon environments
NASA Technical Reports Server (NTRS)
Bartolotta, Paul A.; Verrilli, Michael J.
1992-01-01
A series of tension-tension, load-controlled thermomechanical fatigue (TMF) tests were conducted on a titanium aluminide composite in both laboratory air and a flowing argon environment. Results from these tests show that the environment plays an increasingly important role as applied stress levels are decreased. Differences in damage mechanisms between the two environments were observed which corresponds to observed variations in TMF lives.
Mental Fatigue Impairs Soccer-Specific Physical and Technical Performance.
Smith, Mitchell R; Coutts, Aaron J; Merlini, Michele; Deprez, Dieter; Lenoir, Matthieu; Marcora, Samuele M
2016-02-01
To investigate the effects of mental fatigue on soccer-specific physical and technical performance. This investigation consisted of two separate studies. Study 1 assessed the soccer-specific physical performance of 12 moderately trained soccer players using the Yo-Yo Intermittent Recovery Test, Level 1 (Yo-Yo IR1). Study 2 assessed the soccer-specific technical performance of 14 experienced soccer players using the Loughborough Soccer Passing and Shooting Tests (LSPT, LSST). Each test was performed on two occasions and preceded, in a randomized, counterbalanced order, by 30 min of the Stroop task (mentally fatiguing treatment) or 30 min of reading magazines (control treatment). Subjective ratings of mental fatigue were measured before and after treatment, and mental effort and motivation were measured after treatment. Distance run, heart rate, and ratings of perceived exertion were recorded during the Yo-Yo IR1. LSPT performance time was calculated as original time plus penalty time. LSST performance was assessed using shot speed, shot accuracy, and shot sequence time. Subjective ratings of mental fatigue and effort were higher after the Stroop task in both studies (P < 0.001), whereas motivation was similar between conditions. This mental fatigue significantly reduced running distance in the Yo-Yo IR1 (P < 0.001). No difference in heart rate existed between conditions, whereas ratings of perceived exertion were significantly higher at iso-time in the mental fatigue condition (P < 0.01). LSPT original time and performance time were not different between conditions; however, penalty time significantly increased in the mental fatigue condition (P = 0.015). Mental fatigue also impaired shot speed (P = 0.024) and accuracy (P < 0.01), whereas shot sequence time was similar between conditions. Mental fatigue impairs soccer-specific running, passing, and shooting performance.
Reliability Quantification of the Flexure: A Critical Stirling Convertor Component
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Zampino, Edward J.
2004-01-01
Uncertainties in the manufacturing, fabrication process, material behavior, loads, and boundary conditions results in the variation of the stresses and strains induced in the flexures and its fatigue life. Past experience and the test data at material coupon levels revealed a significant amount of scatter of the fatigue life. Owing to these facts, the design of the flexure, using conventional approaches based on safety factor or traditional reliability based on similar equipment considerations does not provide a direct measure of reliability. Additionally, it may not be feasible to run actual long term fatigue tests due to cost and time constraints. Therefore it is difficult to ascertain material fatigue strength limit. The objective of the paper is to present a methodology and quantified results of numerical simulation for the reliability of flexures used in the Stirling convertor for their structural performance. The proposed approach is based on application of finite element analysis method in combination with the random fatigue limit model, which includes uncertainties in material fatigue life. Additionally, sensitivity of fatigue life reliability to the design variables is quantified and its use to develop guidelines to improve design, manufacturing, quality control and inspection design process is described.
NASA Astrophysics Data System (ADS)
Texier, Damien; Gómez, Ana Casanova; Pierret, Stéphane; Franchet, Jean-Michel; Pollock, Tresa M.; Villechaise, Patrick; Cormier, Jonathan
2016-03-01
The low-cycle fatigue behavior of two direct-aged versions of the nickel-based superalloy Inconel 718 (IN718DA) was examined in the low-strain amplitude regime at intermediate temperature. High variability in fatigue life was observed, and abnormally short lifetimes were systematically observed to be due to crack initiation at (sub)-surface non-metallic inclusions. However, crack initiation within (sub)-surface non-metallic inclusions did not necessarily lead to short fatigue life. The macro- to micro-mechanical mechanisms of deformation and damage have been examined by means of detailed microstructural characterization, tensile and fatigue mechanical tests, and in situ tensile testing. The initial stages of crack micro-propagation from cracked non-metallic particles into the surrounding metallic matrix occupies a large fraction of the fatigue life and requires extensive local plastic straining in the matrix adjacent to the cracked inclusions. Differences in microstructure that influence local plastic straining, i.e., the δ-phase content and the grain size, coupled with the presence of non-metallic inclusions at the high end of the size distribution contribute strongly to the fatigue life variability.
Research on fatigue cracking growth parameters in asphaltic mixtures using computed tomography
NASA Astrophysics Data System (ADS)
Braz, D.; Lopes, R. T.; Motta, L. M. G.
2004-01-01
Distress of asphalt concrete pavement due to repeated bending from traffic loads has been a well-recognized problem in Brazil. If it is assumed that fatigue cracking growth is governed by the conditions at the crack tip, and that the crack tip conditions can be characterized by the stress intensity factor, then fatigue cracking growth as a function of stress intensity range Δ K can be determined. Computed tomography technique is used to detect crack evolution in asphaltic mixtures which were submitted to fatigue tests. Fatigue tests under conditions of controlled stress were carried out using diametral compression equipment and repeat loading. The aim of this work is imaging several specimens at different stages of the fatigue tests. In preliminary studies it was noted that the trajectory of a crack was influenced by the existence of voids in the originally unloaded specimens. Cracks would first be observed in the central region of a specimen, propagating in the direction of the extremities. Analyzing the graphics, that represent the fatigue cracking growth (d c/d N) as a function of stress intensity factor (Δ K), it is noticed that the curve has practically shown the same behavior for all specimens at the same level of the static tension rupture stress. The experimental values obtained for the constants A and n (of the Paris-Erdogan Law) present good agreement with the results obtained by Liang and Zhou.
Development of a fatigue testing setup for dielectric elastomer membrane actuators
NASA Astrophysics Data System (ADS)
Hill, M.; Rizzello, G.; Seelecke, S.
2017-04-01
Dielectric elastomers (DE's) represent a transduction technology with high potential in many fields, including industries, due to their low weight, flexibility, and small energy consumption. For industrial applications, it is of fundamental importance to quantify the lifetime of DE technology, in terms of electrical and mechanical fatigue, when operating in realistic environmental conditions. This work contributes toward this direction, by presenting the development of an experimental setup which permits systematic fatigue testing of DE membranes. The setup permits to apply both mechanical and electrical stimuli to several membranes simultaneously, while measuring at the same time their mechanical (force, deformation) and electrical response (capacitance, resistance). In its final state, the setup will allow to test up to 15 DE membranes at the same time for several thousands of cycles. Control of the modules, monitoring of the actuators, and data acquisition are realized on a cRio FPGA-system running with LabVIEW. The setup is located in a climate chamber, in order to investigate the fatigue mechanisms at different environmental conditions, i.e., in terms of temperature and humidity. The setup consists of two main parts, namely a fatigue group and a measurement group. The fatigue group stays permanently in the climate chamber, while the measurement group is assembled to the fatigue group and allows to perform measurements at 20°C.
Persistent Fatigue in Hematopoietic Stem Cell Transplantation Survivors.
Hacker, Eileen Danaher; Fink, Anne M; Peters, Tara; Park, Chang; Fantuzzi, Giamila; Rondelli, Damiano
Fatigue is highly prevalent after hematopoietic stem cell transplantation (HCT). It has been described as intense and may last for years following treatment. The aim of this study is to compare fatigue, physical activity, sleep, emotional distress, cognitive function, and biological measures in HCT survivors with persistent fatigue (n = 25) with age- and gender-matched healthy controls with occasional tiredness (n = 25). Data were collected using (a) objective, real-time assessments of physical activity and sleep over 7 days; (b) patient-reported fatigue assessments; (c) computerized objective testing of cognitive functioning; and (d) biological measures. Differences between groups were examined using multivariate analysis of variance. Survivors of HCT reported increased physical (P < .001), mental (P < .001), and overall (P < .001) fatigue as well as increased anxiety (P < .05) and depression (P < .01) compared with healthy controls. Red blood cell (RBC) levels were significantly lower in HCT survivors (P < .001). Levels of RBC for both groups, however, were in the normal range. Tumor necrosis factor-α (P < .001) and interleukin-6 (P < .05) levels were significantly higher in HCT survivors. Persistent fatigue in HCT survivors compared with healthy controls with occasional tiredness is accompanied by increased anxiety and depression along with decreased RBC counts. Elevated tumor necrosis factor-α and interleukin-6 levels may be important biomarkers. This study provides preliminary support for the conceptualization of fatigue as existing on a continuum, with tiredness anchoring one end and exhaustion the other. Persistent fatigue experienced by HCT survivors is more severe than the occasional tiredness of everyday life.
High rates of fatigue and sleep disturbances in dystonia.
Wagle Shukla, A; Brown, R; Heese, K; Jones, J; Rodriguez, R L; Malaty, I M; Okun, M S; Kluger, B M
2016-10-01
Nonmotor symptoms in dystonia are increasingly recognized to impair the quality of life. The primary objective of this study was to determine the prevalence of fatigue and sleep disturbances in dystonia and to ascertain their impact on quality of life using standardized questionnaires. Dystonia patients presenting to a Botulinum toxin clinic were prospectively administered Fatigue Severity Scale (FSS), Multidimensional Fatigue Inventory (MFI), Epworth Sleepiness Scale (ESS) and Parkinson's Disease Sleep Scale (PDSS) for assessment of fatigue and sleep disturbances. Health-related Quality of life (HRQOL) was determined using MOS SF-36 scale and depressive symptoms were assessed using the Beck Depression Inventory II. Ninety-one patients with dystonia participated (66 women, 25 men, mean age 60 ± 17 years). Nine subjects had generalized dystonia, 18 segmental dystonia and 64 had focal dystonia. Moderate to severe fatigue was present in 43% of the cohort (FSS), excessive daytime somnolence in 27% (ESS) and other sleep disturbances in 26% (PDSS). FSS and MFI scores correlated significantly with HRQOL even when controlled for depression and sleep disturbances. Excessive daytime somnolence and nocturnal sleep disturbances correlated significantly with the HRQOL; however, these effects were not seen for daytime somnolence when controlled for depression. Psychometric testing found adequate reliabilities and convergent validities for both fatigue and sleep scales. Fatigue and sleep disturbances revealed high prevalence rates in this large, first of its dystonia study. They negatively impacted the quality of life even when controlled for comorbid depression.
Vargas, Sara; Antoni, Michael H.; Carver, Charles S.; Lechner, Suzanne C.; Wohlgemuth, William; Llabre, Maria; Blomberg, Bonnie B.; Glück, Stefan; DerHagopian, Robert P.
2015-01-01
Background Sleep disruption and fatigue are ubiquitous among cancer patients and is a source of stress that may compromise treatment outcomes. Previously we showed that a cognitive behavioral stress management (CBSM) intervention reduced anxiety and other stress-related processes in women undergoing primary treatment for breast cancer. Purpose This study examined secondary outcomes from a CBSM intervention trial for women with early-stage breast cancer to test if CBSM would improve sleep quality and fatigue among these patients at a single site in Southern Florida. CBSM-related effects have already been demonstrated for indicators of psychosocial adaptation (e.g., general and cancer-related anxiety). Methods Patients were randomized to CBSM (n = 120) or a one-day psychoeducation control group (n = 120). The Pittsburgh Sleep Quality Index (PSQI) and Fatigue Symptom Inventory were completed prior to randomization and 6 and 12 months after the baseline assignment. Results In latent growth analyses, women in CBSM reported greater improvements in PSQI sleep quality scores than controls, although there were no significant differences between conditions on PSQI total scores. Women in CBSM also reported greater reductions in fatigue-related daytime interference than controls, though there were no significant differences in changes in fatigue intensity. Changes in sleep quality were associated with changes in fatigue. Conclusions Future work may consider integrating sleep and fatigue content into stress management interventions for women with early-stage breast cancer. PMID:24318654
DOT National Transportation Integrated Search
2011-06-01
The main objective of this study is to investigate the use of the semi-circular bend (SCB) : test as a quality assurance/quality control (QA/QC) measure for field construction. : Comparison of fracture properties from the SCB test and fatigue beam te...
Evaluation of the New B-REX Fatigue Testing System for Multi-Megawatt Wind Turbine Blades: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, D.; Musial, W.; Engberg, S.
2004-12-01
The National Renewable Energy Laboratory (NREL) recently developed a new hybrid fatigue testing system called the Blade Resonance Excitation (B-REX) test system. The new system uses 65% less energy to test large wind turbine blades in half the time of NREL's dual-axis forced-displacement test method with lower equipment and operating costs. The B-REX is a dual-axis test system that combines resonance excitation with forced hydraulic loading to reduce the total test time required while representing the operating strains on the critical inboard blade stations more accurately than a single-axis test system. The analysis and testing required to fully implement themore » B-REX was significant. To control unanticipated blade motion and vibrations caused by dynamic coupling between the flap, lead-lag, and torsional directions, we needed to incorporate additional test hardware and control software. We evaluated the B-REX test system under stable operating conditions using a combination of various sensors. We then compared our results with results from the same blade, tested previously using NREL's dual-axis forced-displacement test method. Experimental results indicate that strain levels produced by the B-REX system accurately replicated the forced-displacement method. This paper describes the challenges we encountered while developing the new blade fatigue test system and the experimental results that validate its accuracy.« less
A longitudinal study to explain the pain-depression link in older adults with osteoarthritis.
Hawker, Gillian A; Gignac, Monique A M; Badley, Elizabeth; Davis, Aileen M; French, Melissa R; Li, Ye; Perruccio, Anthony V; Power, J Denise; Sale, Joanna; Lou, Wendy
2011-10-01
To evaluate whether osteoarthritis (OA) pain determines depressed mood, taking into consideration fatigue and disability and controlling for other factors. In a community cohort with hip/knee OA, telephone interviews assessed OA pain and disability (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]), fatigue (Multidimensional Fatigue Symptom Inventory), depressed mood (Center for Epidemiologic Studies Depression Scale), and covariates (demographics, self-rated health, comorbidity, pain coping, pain catastrophizing, and social support) at 3 time points over 2 years. Drawing on previous research, a path model was developed to test the interrelationships among the key concepts (pain, depression, fatigue, disability) over time, controlling for covariates. The baseline mean age was 75.4 years; 78.5% of the subjects were women, 37.2% were living alone, and 15.5% had ≥3 comorbid conditions. WOMAC scores indicated moderate OA symptoms and disability. From the final model with 529 subjects, adjusting for covariates, we found that current OA pain strongly predicted future fatigue and disability (both short and long term), that fatigue and disability in turn predicted future depressed mood, that depressed mood and fatigue were interrelated such that depressed mood exacerbated fatigue and vice versa, and that fatigue and disability, but not depressed mood, led to worsening of OA pain. Controlling for other factors, OA pain determined subsequent depressed mood through its effect on fatigue and disability. These effects led to worsening of pain and disability over time. These results support the need for improved pain management in OA to prevent or attenuate the downstream effects of pain on disability and mood. Copyright © 2011 by the American College of Rheumatology.
Cashman, Paul M; Schneider, Robert L; Schneider, Galen B; Stanford, Clark M; Clancy, James M; Qian, Fang
2011-10-01
This study analyzed baseline and post-fatigue reverse-torque values (RTVs) for a specific brand control abutment relative to a third party compatible abutment. The purpose of this study was to compare the abutments' fatigue resistance to simulated function, using RTVs as an indication of residual preload at the implant/abutment interface. Forty Straumann tissue-level implants were mounted in resin and divided into four groups (n = 10). Forty abutments were seated, 20 control and 20 third-party abutments, according to manufacturer guidelines. Ten abutments from each manufacturer were evaluated for RTV without fatigue loading, using a calibrated digital torque gauge to provide a baseline RTVs. Fatigue loading was carried out on the remaining ten specimens from each manufacturer according to ISO 14801 guidelines. A moving-magnet linear motor was used to load one specimen per sequence, alternating from 10 to 200 N at 15 Hz for 5×10(6) cycles. RTV was recorded post-fatigue loading. The results were subjected to two-sample t-testing and two-way ANOVA. Scanning electron microphotography was carried out on three specimens from both manufacturers at baseline and post-fatigue cycling to visualize thread geometry and the abutment/implant interface. The data indicated that mean post-fatigue RTV observed for the control group was significantly higher than the third-party group (RTV 42.65 ± 6.70 N vs. 36.25 ± 2.63 N, p= 0.0161). Visual differences at the macro/microscopic level were also apparent for thread geometry, with third-party abutments demonstrating considerably greater variation in geometrical architecture than control specimens. Within the limitations of this in vitro model, the effect of component manufacturer resulted in a significantly higher RTV in the control group (two-way ANOVA, p= 0.0032) indicating greater residual preload; however, there was no significant decrease in post-fatigue RTV for either manufacturer compared to baseline. © 2011 by The American College of Prosthodontists.
Isometric muscle fatigue of the paravertebral and upper extremity muscles after whiplash injury.
Rastovic, Pejana; Gojanovic, Marija Definis; Berberovic, Marina; Pavlovic, Marko; Lesko, Josip; Galic, Gordan; Pandza, Maja
2017-01-01
Whiplash-associated disorders (WAD) result from injury of neck structures that most often occur during traffic accidents as a result of rapid acceleration-deceleration. The dominant symptoms manifest in the musculoskeletal system and include increased fatigue. Because of the frequency of whiplash injuries, a simple, cheap and useful diagnostic tool is needed to differentiate whiplash injury from healthy patients or those faking symptoms. To determine muscle fatigue in patients with whiplash injury in six body positions. Analytical cross-sectional study. Emergency center, university hospital. We studied patients with whiplash injury from vehicular traffic accidents who presented to the emergency center within 6 hours of sustaining the injury. We determined whiplash injury grade according to the Quebec Task Force (QTF) classification and measured isometric muscle endurance in six different body positions. Control subjects for each patient were matched by age, gender and anthropomorphic characteristics. Cut-off values were determined to distinguish patients with whiplash injury from controls and for determination of injury grade . QTF grade, time to muscle fatigue in seconds. From September 2013 to September 2016, we enrolled 75 patients with whiplash injury and 75 matching control subjects. In all six positions, the patients with whiplash injury felt muscle fatigue faster than equivalent controls (P < .05) and the time to onset of muscle fatigue decreased with increasing injury grades in all six positions. Assignment to the patient or control group and to injury grade could be predicted with more than 90% accuracy on the basis of time to muscle fatigue. The most efficient position was the highest injury grade, by which 99.9% of the patients were accurately categorized. Isometric muscle endurance correlated with whiplash injury grade in all six positions (P < .01). Under clinical conditions, muscle endurance and the appearance of isometric muscle fatigue during testing can be a useful indicator of whiplash injury and grade. The size of the sample was small. An objective parameter such as electromyography is needed to confirm isometric muscle fatigue.
Seebacher, Barbara; Kuisma, Raija; Glynn, Angela; Berger, Thomas
2017-02-01
Motor imagery and rhythmic auditory stimulation are physiotherapy strategies for walking rehabilitation. To investigate the effect of motor imagery combined with rhythmic cueing on walking, fatigue and quality of life (QoL) in people with multiple sclerosis (MS). Individuals with MS and Expanded Disability Status Scale scores of 1.5-4.5 were randomised into one of three groups: 17 minutes of motor imagery, six times per week, for 4 weeks, with music (A) or metronome cues (B), both with verbal cueing, and (C) controls. Primary outcomes were walking speed (Timed 25-Foot Walk) and distance (6-Minute Walk Test). Secondary outcomes were walking perception (Multiple Sclerosis Walking Scale-12), fatigue (Modified Fatigue Impact Scale) and QoL (Short Form-36 Health Survey, Multiple Sclerosis Impact Scale-29, Euroquol-5D-3L Questionnaire). Of the 112 participants randomised, 101 completed the study. Compared to controls, both interventions significantly improved walking speed, distance and perception. Significant improvements in cognitive but not psychosocial fatigue were seen in the intervention groups, and physical fatigue improved only in the music-based group. Both interventions improved QoL; however, music-cued motor imagery was superior at improving health-related QoL. Rhythmic-cued motor imagery improves walking, fatigue and QoL in people with MS, with music-cued motor imagery being more effective.
Childhood Adversity and Cumulative Life Stress: Risk Factors for Cancer-Related Fatigue.
Bower, Julienne E; Crosswell, Alexandra D; Slavich, George M
2014-01-01
Fatigue is a common symptom in healthy and clinical populations, including cancer survivors. However, risk factors for cancer-related fatigue have not been identified. On the basis of research linking stress with other fatigue-related disorders, we tested the hypothesis that stress exposure during childhood and throughout the life span would be associated with fatigue in breast cancer survivors. Stress exposure was assessed using the Stress and Adversity Inventory, a novel computer-based instrument that assesses for 96 types of acute and chronic stressors that may affect health. Results showed that breast cancer survivors with persistent fatigue reported significantly higher levels of cumulative lifetime stress exposure, including more stressful experiences in childhood and in adulthood, compared to a control group of nonfatigued survivors. These findings identify a novel risk factor for fatigue in the growing population of cancer survivors and suggest targets for treatment.
Childhood Adversity and Cumulative Life Stress: Risk Factors for Cancer-Related Fatigue
Bower, Julienne E.; Crosswell, Alexandra D.; Slavich, George M.
2013-01-01
Fatigue is a common symptom in healthy and clinical populations, including cancer survivors. However, risk factors for cancer-related fatigue have not been identified. On the basis of research linking stress with other fatigue-related disorders, we tested the hypothesis that stress exposure during childhood and throughout the life span would be associated with fatigue in breast cancer survivors. Stress exposure was assessed using the Stress and Adversity Inventory, a novel computer-based instrument that assesses for 96 types of acute and chronic stressors that may affect health. Results showed that breast cancer survivors with persistent fatigue reported significantly higher levels of cumulative lifetime stress exposure, including more stressful experiences in childhood and in adulthood, compared to a control group of nonfatigued survivors. These findings identify a novel risk factor for fatigue in the growing population of cancer survivors and suggest targets for treatment. PMID:24377083
Hilfer, Paul B; Bergeron, Brian E; Mayerchak, Michael J; Roberts, Howard W; Jeansonne, Billie G
2011-01-01
Novel nickel-titanium rotary files with proprietary manufacturing techniques have recently been marketed. The purpose of this study was to assess multiple autoclave cycle effects on cyclic fatigue of GT Series X files (Dentsply Tulsa Dental Specialties, Tulsa, OK) and Twisted Files (SybronEndo, Orange, CA) METHODS: A jig using a 5-mm radius curve with 90° of maximum file flexure was used to induce cyclic fatigue failure. Files (n = 10) representing each experimental group (GT Series X 20/.04 and 20/.06; Twisted Files 25/.04 and 25/.06) were first tested to establish baseline mean cycles to failure (MCF). Experimental groups (n = 20) were then cycled to 25% of the established baseline MCF and then autoclaved. Additional autoclaving was accomplished at 50% and 75% of MCF followed by continual testing until failure. Control groups (n = 20) underwent the same procedures except autoclaving was not accomplished. The GT Series X (20/.04 and 20/.06) files showed no significant difference (p = 0.918/p = 0.096) in MCF for experimental versus control files. Twisted Files (25/.04) showed no significant difference (p = 0.432) in MCF between experimental and control groups. However, the Twisted Files (25/.06) experimental group showed a significantly lower (p = 0.0175) MCF compared with the controls. Under the conditions of this evaluation, autoclave sterilization significantly decreased cyclic fatigue resistance of one of the four file groups tested. Repeated autoclaving significantly reduced the MCF of 25/.06 Twisted Files; however, 25/.04 Twisted Files and both GT Series X files tested were not significantly affected by the same conditions. Published by Elsevier Inc.
Alguacil Diego, I M; Pedrero Hernández, C; Molina Rueda, F; Cano de la Cuerda, R
2012-04-01
Postural and balance disorders, functionality impairment and fatigue, are the most incapacitating problems in multiple sclerosis (MS) patients. Whole Body Vibration (WBV), through the transmission of mechanical stimuli, appears to be a useful therapeutic tool in the treatment of neurological diseases. The objective of this study is to assess the effect of the WBV on postural control, balance, functionality and fatigue in patients with MS. A total of 34 patients with mild-moderate MS were randomised into a control group and an intervention group. For the intervention group, the protocol consisted of 5 consecutive days, daily series of 5 periods of 1 minute of duration of WBV at a frequency of 6 Hz. Posturographic assessment using the Sensory Organization Test (SOT) and Motor Control Test (MCT), the Timed Get Up and Go Test, 10 metres Test, the Berg Balance Scale and Krupp's Fatigue Severity Scale were used before and after intervention. The analysis showed improvements in the intervention group for conditions SOT 1, SOT 3 and latency in MCT. In the comparison between groups, only the latency or reaction time in MCT improved significantly in favour of the intervention group (from 173.78±12.46 to 161.25±13.64 ms; P=.04). No side-effects were found. The results of this pilot study show that WBV can improve, in the short-term, the time of response to recover the uprightness after sudden disturbances, appearing as a possible therapeutic tool maintaining balance and posture. Copyright © 2011 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.
Thermal-mechanical fatigue test apparatus for metal matrix composites and joint attachments
NASA Technical Reports Server (NTRS)
Westfall, L. J.; Petrasek, D. W.
1985-01-01
Two thermal-mechanical fatigue (TMF) test facilities were designed and developed, one to test tungsten fiber reinforced metal matrix composite specimens at temperature up to 1430C (2600F) and another to test composite/metal attachment bond joints at temperatures up to 760C (1400 F). The TMF facility designed for testing tungsten fiber reinforced metal matrix composites permits test specimen temperature excursions from room temperature to 1430C (2600F) with controlled heating and loading rates. A strain-measuring device measures the strain in the test section of the specimen during each heating and cooling cycle with superimposed loads. Data is collected and recorded by a computer. The second facility is designed to test composite/metal attachment bond joints and to permit heating to a maximum temperature of 760C (1400F) within 10 min and cooling to 150C (300F) within 3 min. A computer controls specimen temperature and load cycling.
Thermal-mechanical fatigue test apparatus for metal matrix composites and joint attachments
NASA Technical Reports Server (NTRS)
Westfall, Leonard J.; Petrasek, Donald W.
1988-01-01
Two thermal-mechanical fatigue (TMF) test facilities were designed and developed, one to test tungsten fiber reinforced metal matrix composite specimens at temperature up to 1430C (2600F) and another to test composite/metal attachment bond joints at temperatures up to 760F (1400F). The TMF facility designed for testing tungsten fiber reinforced metal matrix composites permits test specimen temperature excursions from room temperature to 1430C (2600F) with controlled heating and loading rates. A strain-measuring device measures the strain in the test section of the specimen during each heating and cooling cycle with superimposed loads. Data is collected and recorded by a computer. The second facility is designed to test composite/metal attachment bond joints and to permit heating to a maximum temperature of 760C (1400F) within 10 min and cooling to 150C (300F) within 3 min. A computer controls specimen temperature and load cycling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyum, E.A.
1993-12-01
This research, the first load-controlled tension-compression fatigue testing to be performed on a MMC, extends the existing knowledge of MMC fatigue damage mechanisms to include the tension compression loading condition. To accomplish this, a (0/90)2, SCS-6/Ti-15-3 laminate was subjected to tension-tension fatigue at room temperature, and tension-compression fatigue at both room temperature and 427 deg C. Stress and strain data was taken to evaluate the macro-mechanic behavior of the material. Microscopy and fractography were performed to characterize the damage on a micro-mechanic level. On a maximum applied stress basis, the room temperature tension-tension specimens had longer fatigue lives than themore » room temperature tension-compression specimens. The room and high temperature tension-compression fatigue lives were nearly identical in the fiber-dominated high stress region of the SN curve. However, the increased ductility and diffused plasticity of the titanium matrix at 427 deg C delayed the onset and severity of matrix cracking, and thus increased the elevated temperature fatigue lives in the matrix dominated region of the SN curve. In all cases, matrix damage initiated at reaction zone cracks which nucleated both matrix plasticity and matrix cracking. Metal matrix composite, Elevated temperature, Fatigue testing, Compression, Fully-reversed, Titanium, Silicon carbide.« less
Fatigue Properties of Modified 316LN Stainless Steel at 4 K for High Field Cable-In Applications
NASA Astrophysics Data System (ADS)
Toplosky, V. J.; Walsh, R. P.; Han, K.
2010-04-01
Cable-In-Conduit-Conductor (CICC) alloys, exposed to Nb3Sn reaction heat-treatments, such as modified 316LN require a design specific database. A lack of fatigue life data (S-n curves) that could be applied in the design of the ITER CS and the NHMFL Series Connected Hybrid magnets is the impetus for the research presented here. The modified 316LN is distinguished by a lower carbon content and higher nitrogen content when compared to conventional 316LN. Because the interstitial alloying elements affect the mechanical properties significantly, it is necessary to characterize this alloy in a systematic way. In conjunction, to ensure magnet reliability and performance, several criteria and expectations must be met, including: high fatigue life at the operating stresses, optimal stress management at cryogenic temperatures and thin walled conduit to reduce coil mass. Tension-tension load control axial fatigue tests have good applicability to CICC solenoid magnet design, thus a series of 4 K strength versus fatigue life curves have been generated. In-situ samples of 316LN base metal, seam welded, butt welded and seam plus butt welded are removed directly from the conduit in order to address base and weld material fatigue life variability. The more than 30 fatigue tests show good grouping on the fatigue life curve and allow discretionary 4 K fatigue life predictions for conduit made with modified 316LN.
Macgregor, Lewis J; Ditroilo, Massimiliano; Smith, Iain J; Fairweather, Malcolm M; Hunter, Angus M
2016-08-01
Assessments of skeletal-muscle functional capacity often necessitate maximal contractile effort, which exacerbates muscle fatigue or injury. Tensiomyography (TMG) has been investigated as a means to assess muscle contractile function after fatigue; however, observations have not been contextualized by concurrent physiological measures. To measure peripheral-fatigue-induced alterations in mechanical and contractile properties of the plantar-flexor muscles through noninvasive TMG concurrently with maximal voluntary contraction (MVC) and passive muscle tension (PMT) to validate TMG as a gauge of peripheral fatigue. Pre- and posttest intervention with control. University laboratory. 21 healthy male volunteers. Subjects' plantar flexors were tested for TMG parameters, along with MVC and PMT, before and after either a 5-min rest period (control) or a 5-min electrical-stimulation intervention (fatigue). Temporal (contraction velocity) and spatial (radial displacement) contractile parameters of the gastrocnemius medialis were recorded through TMG. MVC was measured as an indicator of muscle fatigue, and PMT was measured to assess muscle stiffness. Radial displacement demonstrated a fatigue-associated reduction (3.3 ± 1.2 vs 4.0 ± 1.4 mm, P = .031), while contraction velocity remained unaltered. In addition, MVC significantly declined by 122.6 ± 104 N (P < .001) after stimulation (fatigue). PMT was significantly increased after fatigue (139.8 ± 54.3 vs 111.3 ± 44.6 N, P = .007). TMG successfully detected fatigue, evident from reduced MVC, by displaying impaired muscle displacement accompanied by elevated PMT. TMG could be useful in establishing skeletal-muscle fatigue status without exacerbating the functional decrement of the muscle.
The fatigue life of a cobalt-chromium alloy after laser welding.
Al-Bayaa, Nabil Jalal Ahmad; Clark, Robert K F; Juszczyk, Andrzej S; Radford, David R
2011-03-01
The aim of this study was to investigate the fatigue life of laser welded joints in a commercially available cast cobalt-chromium alloy. Twenty rod shaped specimens (40 mm x 1.5 mm) were cast and sand blasted. Ten specimens were used as controls and the remaining ten were sectioned and repaired using a pulsed Nd: YAG laser welder. All specimens were subjected to fatigue testing (30N - 2Hz) in a controlled environment. A statistically significant difference in median fatigue life was found between as-cast and laser welded specimens (p < 0.001). Consequently, the technique may not be appropriate for repairing cobalt chromium clasps on removable partial dentures. Scanning electron microscopy indicated the presence of cracks, pores and constriction of the outer surface in the welded specimens despite 70% penetration of the weld.
In vitro fatigue behavior of restorative composites and glass ionomers.
Braem, M J; Lambrechts, P; Gladys, S; Vanherle, G
1995-03-01
This in vitro study was conducted to investigate the fatigue behavior of several dental restoratives, including composites, glass ionomers and a resin-reinforced glass ionomer. Fatigue was imposed under a reverse stress-controlled regimen, following a staircase approach. Samples were stored and tested under both dry and wet conditions. The following parameters were measured and analyzed: Young's modulus, restrained fracture strength, and flexural fatigue limit. As a general trend, all products showed a decrease in Young's modulus following water sorption. For all products except the resin-reinforced glass ionomer, the same trend was seen in the restrained fracture strength. This is, however, no longer valid for the flexural fatigue limit: the trend is steady-state for the glass ionomers, status quo for the resin-reinforced glass ionomer, and all composites tested show a decrease. The diversity in structure of both composites and glass ionomers does not allow findings for one product to be extrapolated to other similar products.
Su, Chun; Zhou, Jianzhong; Meng, Xiankai; Huang, Shu
2016-09-26
As a new treatment process after welding, the process parameters of laser shock peening (LSP) in dynamic strain aging (DSA) temperature regimes can be precisely controlled, and the process is a non-contact one. The effects of LSP at elevated temperatures on the distribution of the surface residual stress of AA6061-T6 welded joints were investigated by using X-ray diffraction technology with the sin² ϕ method and Abaqus software. The fatigue life of the welded joints was estimated by performing tensile fatigue tests. The microstructural evolution in surface and fatigue fractures of the welded joints was presented by means of surface integrity and fracture surface testing. In the DSA temperature regime of AA6061-T6 welded joints, the residual compressive stress was distributed more stably than that of LSP at room temperature. The thermal corrosion resistance and fatigue properties of the welded joints were also improved. The experimental results and numerical analysis were in mutual agreement.
Su, Chun; Zhou, Jianzhong; Meng, Xiankai; Huang, Shu
2016-01-01
As a new treatment process after welding, the process parameters of laser shock peening (LSP) in dynamic strain aging (DSA) temperature regimes can be precisely controlled, and the process is a non-contact one. The effects of LSP at elevated temperatures on the distribution of the surface residual stress of AA6061-T6 welded joints were investigated by using X-ray diffraction technology with the sin2ϕ method and Abaqus software. The fatigue life of the welded joints was estimated by performing tensile fatigue tests. The microstructural evolution in surface and fatigue fractures of the welded joints was presented by means of surface integrity and fracture surface testing. In the DSA temperature regime of AA6061-T6 welded joints, the residual compressive stress was distributed more stably than that of LSP at room temperature. The thermal corrosion resistance and fatigue properties of the welded joints were also improved. The experimental results and numerical analysis were in mutual agreement. PMID:28773920
Hall, Daniel L; Antoni, Michael H; Lattie, Emily G; Jutagir, Devika R; Czaja, Sara J; Perdomo, Dolores; Lechner, Suzanne C; Stagl, Jamie M; Bouchard, Laura C; Gudenkauf, Lisa M; Traeger, Lara; Fletcher, MaryAnn; Klimas, Nancy G
Persistent fatigue and depressive symptoms are both highly prevalent among patients with Chronic Fatigue Syndrome/Myalgic Encephalomyelitis (CFS/ME) as well as breast cancer survivors. This study aimed to assess and directly compare perceptions of fatigue as highly interfering in one's daily functioning in both patient populations to better understand their relationships with depressed mood. Participants were 95 female CFS/ME patients and 67 females who were approximately 5 years post-treatment for stage 0-III breast cancer presenting with clinically elevated fatigue severity. Self-report measures were obtained on participants' fatigue-related interference in daily functioning and fatigue severity as well as depressed mood. Hierarchical regression was used to test effects controlling for relevant demographic, psychosocial, and medical covariates. CFS/ME patients endorsed greater depressed mood and fatigue interference than did fatigued breast cancer survivors, p's <.001. These factors were significantly positively correlated among CFS/ME patients (β=.36, p <.001), but not the fatigued breast cancer survivors (β=.18, p =.19). CFS/ME patients reported elevated fatigue symptoms and depression relative to fatigued breast cancer survivors. In the former group, greater depressed mood was highly and significantly associated with greater fatigue-related inference in daily activities. Potential targets for cognitive behavioral interventions are discussed.
NASA Astrophysics Data System (ADS)
Ma, Longzhou; Roy, Shawoon K.
2013-04-01
The fatigue crack propagation (FCP) behavior of two solid-solution-strengthened Ni-based superalloys, INCONEL 617 and HAYNES 230, were studied simultaneously in laboratory air using a constant stress intensity factor (K)-controlled mode with different load ratios (R-ratio) at 700 °C. The FCP tests were performed in both cycle and time-dependent FCP domains to examine the effect of R-ratio on the FCP rate, da/dn. For cycle-dependent FCP test, a 1-s sinusoidal fatigue was applied for a compact tension (CT) specimen of INCONEL 617 and HAYNES 230 to measure their FCP rates. For time-dependent FCP test, a 3-s sinusoidal fatigue with a hold time of 300 s at maximum load was applied. Both cycle/time-dependent FCP behaviors were characterized and analyzed. The results showed that increasing R-ratio would introduce the fatigue incubation and decrease the FCP rates at cycle-dependent FCP tests. On the contrary, fatigue incubation was not observed at time-dependent FCP tests for both INCONEL 617 and HAYNES 230 at each tested R-ratio, suggesting that association of maximum load (Kmax) with crack tip open displacement (CTOD) and environmental factor governed the FCP process. Also, for time-dependent FCP, HAYNES 230 showed lower FCP rates than INCONEL 617 regardless of R-ratio. However, for cycle-dependent FCP, HAYNES 230 showed the lower FCP rates only at high R-ratios. Fracture surface of specimens were examined using SEM to investigate the cracking mechanism under cycle/time-dependent FCP condition with various R-ratios.
Yang, Chiu-Ling; Chen, Chung-Hey
2018-01-01
Gymnastics is a preferable safe exercise for postnatal women performing regularly. The aim of this pilot randomized controlled trial was to determine whether the aerobic gymnastic exercise improves stress, fatigue, sleep quality and depression in postpartum women. Single-blinded, randomized controlled trial held from December 2014 until September 2015. Postnatal clinic of a medical center in southern Taiwan. 140 eligible postnatal women were systematically assigned, with a random start to experimental (n=70) or a control (n=70) group. Engage in aerobic gymnastic exercise at least three times (15min per section) a week for three months using compact disc in the home. Perceived Stress Scale, Postpartum Fatigue Scale, Postpartum Sleep Quality Scale, and Edinburgh Postnatal Depression Scale. In a two-way ANOVA with repeated measures, the aerobic gymnastic exercise group showed significant decrease in fatigue after practicing exercise 4 weeks and the positive effects extended to the 12-week posttests. Paired t-tests revealed that aerobic gymnastic exercise participants had improved significantly in perceived stress and fatigue after 4 weeks gymnastic exercise; these positive effects extended to the 12-week posttests. In addition, the changes in physical symptoms-related sleep inefficiency after 12 weeks gymnastic exercise were significantly decreased in the experimental group compared with the control group. The findings can be used to encourage postnatal women to perform moderate-intensity gymnastic exercise in their daily life to reduce their stress, fatigue and improve sleep quality. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effects of Muscle Atrophy on Motor Control: Cage-size Effects
NASA Technical Reports Server (NTRS)
Stuart, D. G.
1985-01-01
Two populations of male Sprague-Dawley rats were raised either in conventional minimum-specification cages or in a larger cage. When the animals were mature (125 to 150 d), the physiological status of the soleus (SOL) and extensor digitorum longus (EDL) muscles of the small- and large-cage animals were compared. Analysis of whole-muscle properties including the performance of the test muscle during a standardized fatigue test in which the nerve to the test muscle was subjected to supramaximal intermittent stimulation shows: (1) the amplitude, area, mean amplitude, and peak-to-peak rate of the compound muscle action potential decreased per the course of the fatigue test; (2) cage size did not affect the profile of changes for any of the action-potential measurements; (3) changes exhibited in the compound muscle action potential by SOL and EDL were substantially different; and (4) except for SOL of the large-cage rats, there was a high correlation between all four measures of the compound muscle action potential and the peak tetanic force during the fatigue test; i.e., either the electrical activity largely etermines the force profile during the fatigue test or else contractile-related activity substantially affects the compound muscle action potential.
Snell, Christopher R; Stevens, Staci R; Davenport, Todd E; Van Ness, J Mark
2013-11-01
Reduced functional capacity and postexertion fatigue after physical activity are hallmark symptoms of chronic fatigue syndrome (CFS) and may even qualify for biomarker status. That these symptoms are often delayed may explain the equivocal results for clinical cardiopulmonary exercise testing in people with CFS. Test reproducibility in people who are healthy is well documented. Test reproducibility may not be achievable in people with CFS because of delayed symptoms. The objective of this study was to determine the discriminative validity of objective measurements obtained during cardiopulmonary exercise testing to distinguish participants with CFS from participants who did not have a disability but were sedentary. A prospective cohort study was conducted. Gas exchange data, workloads, and related physiological parameters were compared in 51 participants with CFS and 10 control participants, all women, for 2 maximal exercise tests separated by 24 hours. Multivariate analysis showed no significant differences between control participants and participants with CFS for test 1. However, for test 2, participants with CFS achieved significantly lower values for oxygen consumption and workload at peak exercise and at the ventilatory or anaerobic threshold. Follow-up classification analysis differentiated between groups with an overall accuracy of 95.1%. Only individuals with CFS who were able to undergo exercise testing were included in this study. Individuals who were unable to meet the criteria for maximal effort during both tests, were unable to complete the 2-day protocol, or displayed overt cardiovascular abnormalities were excluded from the analysis. The lack of any significant differences between groups for the first exercise test would appear to support a deconditioning hypothesis for CFS symptoms. However, the results from the second test indicated the presence of CFS-related postexertion fatigue. It might be concluded that a single exercise test is insufficient to reliably demonstrate functional impairment in people with CFS. A second test might be necessary to document the atypical recovery response and protracted fatigue possibly unique to CFS, which can severely limit productivity in the home and workplace.
Fatigue behavior of a 2XXX series aluminum alloy reinforced with 15 vol Pct SiCp
NASA Astrophysics Data System (ADS)
Bonnen, J. J.; Allison, J. E.; Jones, J. W.
1991-05-01
The fatigue behavior of a naturally aged powder metallurgy 2xxx series aluminum alloy (Alcoa MB85) and a composite made of this alloy with 15 vol pct SiCp, has been investigated. Fatigue lives were determined using load-controlled axial testing of unnotched cylindrical samples. The influence of mean stress was determined at stress ratios of -1, 0.1, and 0.7. Mean stress had a significant influence on fatigue life, and this influence was consistent with that normally observed in metals. At each stress ratio, the incorporation of SiC reinforcement led to an increase in fatigue life at low and intermediate stresses. When considered on a strain-life basis, however, the composite materials had a somewhat inferior resistance to fatigue. Fatigue cracks initiated from several different microstructural features or defect types, but fatigue life did not vary significantly with the specific initiation site. As the fatigue crack advanced away from the fatigue crack initiation site, increasing numbers of SiC particles were fractured, in agreement with crack-tip process zone models.
A Modified Constant-Stress Coupon for Enhanced Natural Crack Start during Fatigue Testing
2016-05-01
improved numerically controlled manufacture. DSTO Research Report DSTO-RR-0340, July 2009. Wescott R, M Jones, M Heller. Stress analysis for design of...has been confirmed by Yu et al. (2014) through experimental strain measurement as well as fatigue tests under spectrum loading. However, as designed ...the results of analyses of a variety of typical non -optimal non -constant stress dog-bone coupon designs . One of those designs has in fact previously
Influence of shear cutting parameters on the fatigue behavior of a dual-phase steel
NASA Astrophysics Data System (ADS)
Paetzold, I.; Dittmann, F.; Feistle, M.; Golle, R.; Haefele, P.; Hoffmann, H.; Volk, W.
2017-09-01
The influence of the edge condition of car body and chassis components made of steel sheet on fatigue behavior under dynamic loading presents a major challenge for automotive manufacturers and suppliers. The calculated lifetime is based on material data determined by the fatigue testing of specimens with polished edges. Prototype components are often manufactured by milling or laser cutting, whereby in practice, the series components are produced by shear cutting due to its cost-efficiency. Since the fatigue crack in such components usually starts from a shear cut edge, the calculated and experimental determined lifetime will vary due to the different conditions at the shear cut edges. Therefore, the material data determined with polished edges can result in a non-conservative component design. The aim of this study is to understand the relationship between the shear cutting process and the fatigue behavior of a dual-phase steel sheet. The geometry of the shear cut edge as well as the depth and degree of work hardening in the shear affected zone can be adjusted by using specific shear cutting parameters, such as die clearance and cutting edge radius. Stress-controlled fatigue tests of unnotched specimens were carried out to compare the fatigue behavior of different edge conditions. By evaluating the results of the fatigue experiments, influential shear cutting parameters on fatigue behavior were identified. It was possible to assess investigated shear cutting strategies regarding the fatigue behavior of a high-strength steel DP800.
Solder creep-fatigue interactions with flexible leaded parts
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.; Wen, L. C.; Mon, G. R.; Jetter, E.
1992-01-01
With flexible leaded parts, the solder-joint failure process involves a complex interplay of creep and fatigue mechanisms. To better understand the role of creep in typical multi-hour cyclic loading conditions, a specialized non-linear finite-element creep simulation computer program has been formulated. The numerical algorithm includes the complete part-lead-solder-PWB system, accounting for strain-rate dependence of creep on applied stress and temperature, and the role of the part-lead dimensions and flexibility that determine the total creep deflection (solder strain range) during stress relaxation. The computer program has been used to explore the effects of various solder creep-fatigue parameters such as lead height and stiffness, thermal-cycle test profile, and part/board differential thermal expansion properties. One of the most interesting findings is the strong presence of unidirectional creep-ratcheting that occurs during thermal cycling due to temperature dominated strain-rate effects. To corroborate the solder fatigue model predictions, a number of carefully controlled thermal-cycle tests have been conducted using special bimetallic test boards.
2014-06-01
Even well- controlled laboratory testing saw a range of COV from less than 10 percent to over 500 percent for different steels (Tryon & Cruse...identified. This 6-year limit is driven by concerns about corrosion fatigue , a process initiated by water gaining access to the carbon steel of the shaft...physics and is controlled by different parameters and interactions of the many variables involved. Figure 2 depicts the corrosion fatigue sequence of
Three parameters optimizing closed-loop control in sequential segmental neuromuscular stimulation.
Zonnevijlle, E D; Somia, N N; Perez Abadia, G; Stremel, R W; Maldonado, C J; Werker, P M; Kon, M; Barker, J H
1999-05-01
In conventional dynamic myoplasties, the force generation is poorly controlled. This causes unnecessary fatigue of the transposed/transplanted electrically stimulated muscles and causes damage to the involved tissues. We introduced sequential segmental neuromuscular stimulation (SSNS) to reduce muscle fatigue by allowing part of the muscle to rest periodically while the other parts work. Despite this improvement, we hypothesize that fatigue could be further reduced in some applications of dynamic myoplasty if the muscles were made to contract according to need. The first necessary step is to gain appropriate control over the contractile activity of the dynamic myoplasty. Therefore, closed-loop control was tested on a sequentially stimulated neosphincter to strive for the best possible control over the amount of generated pressure. A selection of parameters was validated for optimizing control. We concluded that the frequency of corrections, the threshold for corrections, and the transition time are meaningful parameters in the controlling algorithm of the closed-loop control in a sequentially stimulated myoplasty.
NASA Technical Reports Server (NTRS)
Namkung, M.; Nath, S.; Wincheski, B.; Fulton, J. P.
1994-01-01
A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles and the knowledge of the precise location of the crack tip at any given time. One technique currently available for measuring fatigue crack length is the Potential Drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another popular approach is to optically view the crack using a high magnification microscope, but this entails a person constantly monitoring it. The present proposed technique uses an automated scheme, in order to eliminate the need for a person to constantly monitor the experiment. Another technique under development elsewhere is to digitize an optical image of the test specimen surface and then apply a pattern recognition algorithm to locate the crack tip. A previous publication showed that the self nulling eddy current probe successfully tracked a simulated crack in an aluminum sample. This was the impetus to develop an online real time crack monitoring system. An automated system has been developed which includes a two axis scanner mounted on the tensile testing machine, the probe and its instrumentation and a personal computer (PC) to communicate and control all the parameters. The system software controls the testing parameters as well as monitoring the fatigue crack as it propagates. This paper will discuss the experimental setup in detail and demonstrate its capabilities. A three dimensional finite element model is utilized to model the magnetic field distribution due to the probe and how the probe voltage changes as it scans the crack. Experimental data of the probe for different samples under zero load, static load and high cycle fatigue load will be discussed. The final section summarizes the major accomplishments of the present work, the elements of the future R&D needs and the advantages and disadvantages of using this system in the laboratory and field.
Effects of fatigue induced damage on the longitudinal fracture resistance of cortical bone.
Fletcher, Lloyd; Codrington, John; Parkinson, Ian
2014-07-01
As a composite material, cortical bone accumulates fatigue microdamage through the repetitive loading of everyday activity (e.g. walking). The accumulation of fatigue microdamage is thought to contribute to the occurrence of fragility fractures in older people. Therefore it is beneficial to understand the relationship between microcrack accumulation and the fracture resistance of cortical bone. Twenty longitudinally orientated compact tension fracture specimens were machined from a single bovine femur, ten specimens were assigned to both the control and fatigue damaged groups. The damaged group underwent a fatigue loading protocol to induce microdamage which was assessed via fluorescent microscopy. Following fatigue loading, non-linear fracture resistance tests were undertaken on both the control and damaged groups using the J-integral method. The interaction of the crack path with the fatigue induced damage and inherent toughening mechanisms were then observed using fluorescent microscopy. The results of this study show that fatigue induced damage reduces the initiation toughness of cortical bone and the growth toughness within the damage zone by three distinct mechanisms of fatigue-fracture interaction. Further analysis of the J-integral fracture resistance showed both the elastic and plastic component were reduced in the damaged group. For the elastic component this was attributed to a decreased number of ligament bridges in the crack wake while for the plastic component this was attributed to the presence of pre-existing fatigue microcracks preventing energy absorption by the formation of new microcracks.
Examining depletion theories under conditions of within-task transfer.
Brewer, Gene A; Lau, Kevin K H; Wingert, Kimberly M; Ball, B Hunter; Blais, Chris
2017-07-01
In everyday life, mental fatigue can be detrimental across many domains including driving, learning, and working. Given the importance of understanding and accounting for the deleterious effects of mental fatigue on behavior, a growing body of literature has studied the role of motivational and executive control processes in mental fatigue. In typical laboratory paradigms, participants complete a task that places demand on these self-control processes and are later given a subsequent task. Generally speaking, decrements to subsequent task performance are taken as evidence that the initial task created mental fatigue through the continued engagement of motivational and executive functions. Several models have been developed to account for negative transfer resulting from this "ego depletion." In the current study, we provide a brief literature review, specify current theoretical approaches to ego-depletion, and report an empirical test of current models of depletion. Across 4 experiments we found minimal evidence for executive control depletion along with strong evidence for motivation mediated ego depletion. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Beaulieu-Bonneau, Simon; Fortier-Brochu, Émilie; Ivers, Hans; Morin, Charles M
2017-03-01
The objectives of this study were to compare individuals with traumatic brain injury (TBI) and healthy controls on neuropsychological tests of attention and driving simulation performance, and explore their relationships with participants' characteristics, sleep, sleepiness, and fatigue. Participants were 22 adults with moderate or severe TBI (time since injury ≥ one year) and 22 matched controls. They completed three neuropsychological tests of attention, a driving simulator task, night-time polysomnographic recordings, and subjective ratings of sleepiness and fatigue. Results showed that participants with TBI exhibited poorer performance compared to controls on measures tapping speed of information processing and sustained attention, but not on selective attention measures. On the driving simulator task, a greater variability of the vehicle lateral position was observed in the TBI group. Poorer performance on specific subsets of neuropsychological variables was associated with poorer sleep continuity in the TBI group, and with a greater increase in subjective sleepiness in both groups. No significant relationship was found between cognitive performance and fatigue. These findings add to the existing evidence that speed of information processing is still impaired several years after moderate to severe TBI. Sustained attention could also be compromised. Attention seems to be associated with sleep continuity and daytime sleepiness; this interaction needs to be explored further.
Pitcher, Mark J.; Behm, David G.; MacKinnon, Scott N.
2007-01-01
Studies employing modified Biering-Sørenson tests have reported that low back endurance is related to the potential for developing low back pain. Understanding the manner in which spinal musculature fatigues in people with and without LBP is necessary to gain insight into the sensitivity of the modified Biering-Sørenson test to differentiate back health. Twenty male volunteers were divided into a LBP group of subjects with current subacute or a history of LBP that limited their activity (n = 10) and a control group (n = 10). The median frequency of the fast Fourier transform was calculated from bilateral surface electromyography (EMG) of the upper lumbar erector spinae (ULES), lower lumbar erector spinae (LLES) and biceps femoris while maintaining a prescribed modified Biering-Sørensen test position and exerting isometric forces equivalent to 100, 120, 140 and 160% of the estimated mass of the head-arms-trunk (HAT) segment. Time to failure was also investigated across the percentages of HAT. Fatigue time decreased with increasing load and differences between groups increased as load increased, however these differences were not significant. Significant differences in the EMG median frequency between groups occurred in the right biceps femoris (p ≤ 0.05) with significant pairwise differences occurring at 140% for the left biceps femoris and at 160% for the right biceps femoris. There were significant pairwise differences at 120% for average EMG of the right biceps femoris and at 140% for the right ULES, and right and left biceps femoris (p ≤ 0.05). The modified Biering-Sørensen test as usually performed at 100% HAT is not sufficient to demonstrate significant differences between controls and subjects with varying degrees of mild back disability based on the Oswestry classification. Key pointsThe results do not wholly support the modified Biering-Sørensen test utilizing resistance of 100% HAT to discern differences in fatigue in subjects with mild low back pain.A greater activation of the biceps femoris by low back pain individuals probably contributed to the lack of significant differences in back fatigue times.The possibility exists that subjects with more sophisticated strategies could yield higher fatigue times despite inferior neuromuscular fatigue and the existence of low back pain. PMID:24149491
Topçuoğlu, Hüseyin Sinan; Pala, Kanşad; Aktı, Ahmet; Düzgün, Salih; Topçuoğlu, Gamze
2016-07-01
The aim of this study was to investigate the effect of immersion in sodium hypochlorite (NaOCl) on cyclic fatigue resistance of three different rotary nickel-titanium (NiTi) retreatment files. A total of 90 new ProTaper, D-RaCe, and Mtwo retreatment files were tested. Thirty files of the same brand were randomly assigned to two groups (n = 15). Group 1 was no immersion (control group) and 16 mm of group 2 instruments were immersed in 5 % NaOCl at 37 °C for 5 min. All instruments were then tested for cyclic fatigue. Resistance to cyclic fatigue was determined by counting the numbers of cycles to failure in a 60° curve with a 5-mm radius, recording the time in seconds to fracture. Data were analyzed by two-way analysis of variance. Resistance to cyclic fatigue decreased significantly for D-RaCe retreatment files after immersion in NaOCl. ProTaper and Mtwo retreatment files were not affected from immersion to NaOCl. D-RaCe retreatment instruments showed better cyclic fatigue resistance than ProTaper and Mtwo retreatment instruments, and the difference was statistically significant (p < 0.05). There was no significant difference between ProTaper and Mtwo retreatment instrument groups (p > 0.05). D-RaCe retreatment instruments had the highest cyclic fatigue resistance among retreatment files tested in this study, but immersion to NaOCl decreased the cyclic fatigue resistance of D-RaCe retreatment instrument. It should be considered that cyclic fatigue resistance of D-RaCe can decrease in contact with NaOCl during the removal of canal filling material.
The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners
Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda
2014-01-01
Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835
Razazian, Nazanin; Yavari, Zeinab; Farnia, Vahid; Azizi, Akram; Kordavani, Laleh; Bahmani, Dena Sadeghi; Holsboer-Trachsler, Edith; Brand, Serge
2016-05-01
Multiple sclerosis (MS) is a chronic progressive autoimmune disease impacting both body and mind. Typically, patients with MS report fatigue, depression, and paresthesia. Standard treatment consists of immune modulatory medication, though there is growing evidence that exercising programs have a positive influence on fatigue and psychological symptoms such as depression. We tested the hypothesis that, in addition to the standard immune regulatory medication, either yoga or aquatic exercise can ameliorate both fatigue and depression, and we examined whether these interventions also influence paresthesia compared with a nonexercise control condition. Fifty-four women with MS (mean age: M = 33.94 yr, SD = 6.92) were randomly assigned to one of the following conditions: yoga, aquatic exercise, or nonexercise control. Their existing immune modulatory therapy remained unchanged. Participants completed questionnaires covering symptoms of fatigue, depression, and paresthesia, both at baseline and on completion of the study 8 wk later. Compared with the nonexercise control condition and over time, fatigue, depression, and paresthesia decreased significantly in the yoga and aquatic exercise groups. On study completion, the likelihood of reporting moderate to severe depression was 35-fold higher in the nonexercise control condition than in the intervention conditions (yoga and aquatic exercising values collapsed). The pattern of results suggests that for females with MS and treated with standard immune regulatory medication, exercise training programs such as yoga and aquatic exercising positively impact on core symptoms of MS, namely, fatigue, depression, and paresthesia. Exercise training programs should be considered in the future as possible complements to standard treatments.
Murray, D; Hardiman, O; Campion, A; Vance, R; Horgan, F; Meldrum, D
2017-07-01
To investigate the effect of an eight-week home-based arm ergometry aerobic exercise programme on physical fitness, fatigue, activity and quality of life in Polio Survivors. An assessor blinded randomised controlled trial. Home-based exercise. Fifty-five Polio survivors randomised to exercise or control groups. Home-based arm ergometry at an intensity of 50%-70% maximum heart rate, compared with usual physiotherapy care. The Six-minute Arm Test, Fatigue Severity Scale, Physical Activity Scale for Individuals with Physical Disabilities and SF-36. Assessments were completed at baseline and at eight weeks. There was no significant difference in the primary outcome, exercising heart rate during the Six-minute Arm Test, between the groups at follow-up [97.6 (SD10.1) compared to 102.4 (SD13.7) beats per minute ( P=0.20)]. Blood pressure was significantly lower in the intervention group at follow-up [systolic blood pressure 132(18.6)mmHg compared to 144.1(14.6)mmHg ( P=0.002)]. There were no between group differences in the Fatigue Severity Scale ( P=0.25) or Physical Activity Scale for Individuals with Physical Disabilities ( P=0.49), with a small difference in SF-36 physical component score ( P=0.04). This home-based arm ergometry programme successfully facilitated aerobic exercise in Polio Survivors, but did not result in a significant change in physical fitness, measured by the Six-minute Arm Test.
Learning to control an SSVEP-based BCI speller in naïve subjects.
Zhihua Tang; Yijun Wang; Guoya Dong; Weihua Pei; Hongda Chen
2017-07-01
High-speed steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) has been demonstrated in several recent studies. This study aimed to investigate some issues regarding feasibility of learning to control an SSVEP-based BCI speller in naïve subjects. An experiment with new BCI users was designed to answer the following questions: (1) How many people can use the SSVEP-BCI speller? (2) How much time is required to train the user? (3) Does continuous system use lead to user fatigue and deteriorated BCI performance? The experiment consisted of three tasks including a 40-class BCI spelling task, a psychomotor vigilance test (PVT) task, and a test of sleepiness scale. Subjects' reaction time (RT) in the PVT task and the fatigue rank in the sleepiness scale test were used as objective and subjective parameters to evaluate subjects' alertness level. Among 11 naïve subjects, 10 of them fulfilled the 9-block experiment. Four of them showed clear learning effects (i.e., an increasing trend of classification accuracy and information transfer rate (ITR)) over time. The remaining subjects showed stable BCI performance during the whole experiment. The results of RT and fatigue rank showed a gradually increasing trend, which is not significant across blocks. In summary, the results of this study suggest that controlling an SSVEP-based BCI speller is in general feasible to learn by naïve subjects after a short training procedure, showing no clear performance deterioration related to fatigue.
The Effect of Drive Signal Limiting on High Cycle Fatigue Life Analysis
NASA Technical Reports Server (NTRS)
Kihm, Frederic; Rizzi, Stephen A.
2014-01-01
It is common practice to assume a Gaussian distribution of both the input acceleration and the response when modeling random vibration tests. In the laboratory, however, shaker controllers often limit the drive signal to prevent high amplitude peaks. The high amplitudes may either be truncated at a given level (socalled brick wall limiting or abrupt clipping), or compressed (soft limiting), resulting in drive signals which are no longer Gaussian. The paper first introduces several methods for limiting a drive signal, including brick wall limiting and compression. The limited signal is then passed through a linear time-invariant system representing a device under test. High cycle fatigue life predictions are subsequently made using spectral fatigue and rainflow cycle counting schemes. The life predictions are compared with those obtained from unclipped input signals. Some guidelines are provided to help the test engineer decide how clipping should be applied under different test scenarios.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; Johnston, William M., Jr.
2014-01-01
Mixed mode I-mode II interlaminar tests were conducted on IM7/8552 tape laminates using the mixed-mode bending test. Three mixed mode ratios, G(sub II)/G(sub T) = 0.2, 0.5, and 0.8, were considered. Tests were performed at all three mixed-mode ratios under quasi-static and cyclic loading conditions, where the former static tests were used to determine initial loading levels for the latter fatigue tests. Fatigue tests at each mixed-mode ratio were performed at four loading levels, Gmax, equal to 0.5G(sub c), 0.4G(sub c), 0.3G(sub c), and 0.2G(sub c), where G(sub c) is the interlaminar fracture toughness of the corresponding mixed-mode ratio at which a test was performed. All fatigue tests were performed using constant-amplitude load control and delamination growth was automatically documented using compliance solutions obtained from the corresponding quasi-static tests. Static fracture toughness data yielded a mixed-mode delamination criterion that exhibited monotonic increase in Gc with mixed-mode ratio, G(sub II)/G(sub T). Fatigue delamination onset parameters varied monotonically with G(sub II)/G(sub T), which was expected based on the fracture toughness data. Analysis of non-normalized data yielded a monotonic change in Paris law exponent with mode ratio. This was not the case when normalized data were analyzed. Fatigue data normalized by the static R-curve were most affected in specimens tested at G(sub II)/G(sub T)=0.2 (this process has little influence on the other data). In this case, the normalized data yielded a higher delamination growth rate compared to the raw data for a given loading level. Overall, fiber bridging appeared to be the dominant mechanism, affecting delamination growth rates in specimens tested at different load levels and differing mixed-mode ratios.
The Neural Substrates of Self-Evaluation of Mental Fatigue: A Magnetoencephalography Study
Ishii, Akira; Tanaka, Masaaki; Watanabe, Yasuyoshi
2014-01-01
There have been several studies of the neural mechanisms underlying sensation of fatigue. However, little is known about the neural mechanisms underlying self-evaluation of the level of fatigue. The aim of this study was to identify the neural substrates involved in self-evaluation of the level of mental fatigue. We used magnetoencephalography (MEG) with high temporal resolution on 14 healthy participants. During MEG recordings, participants were asked to evaluate their level of mental fatigue in time with execution cues (evaluation trials) or to do nothing in time with execution cues (control trials). The MEG data were analyzed with equivalent current dipole (ECD) and spatial filtering methods to localize the neural activity related to the evaluation of mental fatigue. The daily level of fatigue sensation was assessed using the Checklist Individual Strength questionnaire. In evaluation trials, ECDs were observed in the posterior cingulate cortex (PCC) in seven of 14 participants, with a mean latency of 366.0 ms. The proportion of the participants with ECDs in the PCC was higher in evaluation trials than in control trials (P<0.05, McNemar test). The extent of the decreased delta band power in the PCC (Brodmann’s area 31) 600–700 ms after the onset of the execution cue and that in the dorsolateral prefrontal cortex (DLPFC; Brodmann’s area 9) 800–900 ms after the onset of the execution cue were greater in the evaluation trials than in the control trials. The decrease in delta band power in the DLPFC was positively related to that in the PCC and to the daily level of fatigue sensation. These data suggest that the PCC and DLPFC are involved in the self-evaluation of mental fatigue. PMID:24752677
Depression and helplessness-induced cognitive deficits in the aged.
Kennelly, K J; Hayslip, B; Richardson, S K
1985-01-01
Sixty-six community-residing elderly (mean age = 72.5) were categorized as depressed (mean = 11.3) or nondepressed (mean = 3.9) based on Beck Depression Inventory scores. After a pre-test battery measuring short-term memory and crystallized/fluid intelligence, the subjects responded to a word association task, disguised as a test of interpersonal empathy, under response dependent or response independent reinforcement conditions, or were assigned to a no treatment control. A post-test battery of alternate forms followed. Four of seven measures showed significant pre- to post-test declines in performance. For two of these four, response dependent reinforcement prevented otherwise significant declines. With pre-test differences statistically controlled, depression produced significant post-test deficits in three measures. Response dependent reinforcement eliminated this depression deficit in one measure. The results indicate that depression may exacerbate fatigue effects for the elderly and response dependent reinforcement may prevent fatigue-caused deficits in short-term memory.
Lima, Camila D; Brown, Lee E; Wong, Megan A; Leyva, Whitney D; Pinto, Ronei S; Cadore, Eduardo L; Ruas, Cassio V
2016-11-01
Lima, CD, Brown, LE, Wong, MA, Leyva, WD, Pinto, RS, Cadore, EL, and Ruas, CV. Acute effects of static vs. ballistic stretching on strength and muscular fatigue between ballet dancers and resistance-trained women. J Strength Cond Res 30(11): 3220-3227, 2016-Stretching is used to increase joint range of motion, but the acute effects can decrease muscle strength. However, this may depend on the population or mode of stretching. The purpose of this study was to compare the acute effects of static vs. ballistic stretching on strength and muscular fatigue between ballet dancers and resistance-trained women. Fifteen resistance-trained women (age 23.8 ± 1.80 years, mass 67.47 ± 7.77 kg, height 168.30 ± 5.53 cm) and 12 ballet dancers (age 22.8 ± 3.04 years, mass 58.67 ± 5.65 kg, height 168.00 ± 7.69 cm) performed 5 days of testing. The first day was control (no stretching), whereas the other 4 days were static or ballistic stretching in a counterbalanced order. Range of motion, strength, and fatigue tests were also performed. Both groups demonstrated a significant decrease in hamstrings strength after static (102.71 ± 2.67 N·m) and ballistic stretching (99.49 ± 2.61 N·m) compared with control (113.059 ± 3.25 N·m), with no changes in quadriceps strength. For fatigue, only ballet dancers demonstrated a decrease from control (71.79 ± 4.88%) to ballistic (65.65 ± 8.19%), but no difference with static (65.01 ± 12.29%). These findings suggest that stretching decreases hamstrings strength similarly in ballet dancers and resistance-trained women, with no differences between modes of stretching. However, ballistic stretching only decreased muscular fatigue in ballet dancers, but not in resistance-trained women. Therefore, no stretching should be performed before strength performance. However, ballistic stretching may decrease acute muscular fatigue in ballet dancers.
Tsujimoto, Akimasa; Fischer, Nicholas; Barkmeier, Wayne; Baruth, Andrew; Takamizawa, Toshiki; Latta, Mark; Miyazaki, Masashi
2017-01-01
To examine the effect of reduced phosphoric acid pre-etching times on enamel fatigue bond strength of universal adhesives and surface characteristics by using atomic force microscopy (AFM). Three universal adhesives were used in this study (Clearfil Universal Bond [C], G-Premio Bond [GP], Scotchbond Universal Adhesive [SU]). Four pre-etching groups were employed: enamel pre-etched with phosphoric acid and immediately rinsed with an air-water spray, and enamel pre-etched with phosphoric acid for 5, 10, or 15 s. Ground enamel was used as the control group. For the initial bond strength test, 15 specimens per etching group for each adhesive were used. For the shear fatigue test, 20 specimens per etching group for each adhesive were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. Initial shear bond strengths and fatigue shear strengths of composite adhesively bonded to ground and pre-etched enamel were determined. AFM observations of ground and pre-etched enamel were also conducted, and surface roughness as well as surface area were evaluated. The initial shear bond strengths and fatigue shear strengths of the universal adhesives in the pre-etched groups were significantly higher than those of the control group, and were not influenced by the pre-etching time. Significantly higher surface roughness and surface area of enamel surfaces in pre-etched groups were observed compared with those in the control group. While the surface area was not significantly influenced by etching time, surface roughness of the enamel surfaces in the pre-etched groups significantly increased with pre-etching time. The results of this in vitro study suggest that reduced phosphoric acid pre-etching times do not impair the fatigue bond strength of universal adhesives. Although fatigue bond strength and surface area were not influenced by phosphoric-acid etching times, surface roughness increased with increasing etching time.
NASA Astrophysics Data System (ADS)
Scholz, R.
1995-09-01
Strain-controlled fatigue tests have been performed in torsion on 20% cold-worked Type 316L stainless steel specimens during irradiation with 19 MeV deuterons. A hold-time was imposed at the minimum strain value in the loading cycle. The irradiation creep induced stress relaxation led to the buildup of a mean stress. The number of cycles to failure may be significantly reduced in comparison to analogous continuous cycling tests under thermal conditions.
Eken, Maaike M; Houdijk, Han; Doorenbosch, Caroline A M; Kiezebrink, Francisca E M; van Bennekom, Coen A M; Harlaar, Jaap; Dallmeijer, Annet J
2016-08-01
To investigate the relation between muscle endurance and subjectively reported fatigue, walking capacity, and participation in mildly affected adolescents with cerebral palsy (CP) and peers with typical development. In this case-control study, knee extensor muscle endurance was estimated from individual load-endurance curves as the load corresponding to a 15-repetition maximum in 17 adolescents with spastic CP (six males, 11 females; age 12-19y) and 18 adolescents with typical development (eight males, 10 females; age 13-19y). Questionnaires were used to assess subjectively reported fatigue (Pediatric Quality of Life Inventory Multidimensional Fatigue Scale) and participation (Life-Habits questionnaire). Walking capacity was assessed using the 6-minute walk test. Relations were determined using multiple regression analyses. Muscle endurance related significantly to subjectively reported fatigue and walking capacity in adolescents with CP, while no relations were found for adolescents with typical development (subjectively reported fatigue: regression coefficient β [95% confidence intervals] for CP=23.72 [6.26 to 41.18], for controls=2.72 [-10.26 to 15.69]; walking capacity β for CP=125m [-87 to 337], for controls=2m [-86 to 89]). The 15-repetition maximum did not relate to participation in adolescents with CP. Subjectively reported fatigue and reduced walking capacity in adolescents with CP are partly caused by lower muscle endurance of knee extensors. Training of muscle endurance might contribute to reducing the experience of fatigue and improving walking capacity. Reduced muscle endurance seems to have no effect on participation. © 2016 Mac Keith Press.
Fatigue-induced balance impairment in young soccer players.
Pau, Massimiliano; Ibba, Gianfranco; Attene, Giuseppe
2014-01-01
Although balance is generally recognized to be an important feature in ensuring good performance in soccer, its link with functional performance remains mostly unexplored, especially in young athletes. To investigate changes in balance induced by fatigue for unipedal and bipedal static stances in young soccer players. Crossover study. Biomechanics laboratory and outdoor soccer field. Twenty-one male soccer players (age = 14.5 ± 0.2 years, height = 164.5 ± 5.6 cm, mass = 56.8 ± 6.8 kg). Static balance was assessed with postural-sway analysis in unipedal and bipedal upright stance before and after a fatigue protocol consisting of a repeated sprint ability (RSA) test (2 × 15-m shuttle sprint interspersed with 20 seconds of passive recovery, repeated 6 times). On the basis of the center-of-pressure (COP) time series acquired during the experimental tests, we measured sway area, COP path length, and COP maximum displacement and velocity in the anteroposterior and mediolateral directions. Fatigue increased all sway values in bipedal stance and all values except COP velocity in the mediolateral direction in unipedal stance. Fatigue index (calculated on the basis of RSA performance) was positively correlated with fatigue/rest sway ratio for COP path length and COP velocity in the anteroposterior and mediolateral directions for nondominant single-legged stance. Fatigued players exhibited reduced performance of the postural-control system. Participants with better performance in the RSA test appeared less affected by balance impairment, especially in single-legged stance.
NASA Astrophysics Data System (ADS)
Martinez, Rudy D.
A multiaxial fatigue model is proposed, as it would apply to cylindrical geometry in the form of industrial sized pressure vessels. The main focus of the multiaxial fatigue model will be based on using energy methods with the loading states confined to fluctuating tractions under proportional loading. The proposed fatigue model is an effort to support and enhance existing fatigue life predicting methods for pressure vessel design, beyond the ASME Boiler and Pressure Vessel codes, ASME Section VIII Division 2 and 3, which is currently used in industrial engineering practice for pressure vessel design. Both uniaxial and biaxial low alloy pearlittic-ferritic steel cylindrical cyclic test data are utilized to substantiate the proposed fatigue model. Approximate material hardening and softening aspects from applied load cycling states and the Bauschinger effect are accounted for by adjusting strain control generated hysteresis loops and the cyclic stress strain curve. The proposed fatigue energy model and the current ASME fatigue model are then compared with regards to the accuracy of predicting fatigue life cycle consistencies.
Fatigue Behavior of a Third Generation PM Disk Superalloy
NASA Technical Reports Server (NTRS)
Gayda, John; Gabb, Timothy P.
2008-01-01
The fatigue behavior of a 3rd generation PM disk alloy, LSHR, was studied at 1300 F. Tensile, creep, and fatigue tests were run on smooth and notched (Kt = 2) bars under a variety of conditions. Analysis of smooth bar fatigue data, run under strain and load control with R ratios of 0 and -1, showed that a stress based Smith-Watson-Topper approach could collapse the data set. While the tensile and creep data showed substantial notch strengthening at 1300 F, the fatigue data showed a life deficit for the notch specimens. A viscoplastic finite element model, which accounted for stress relaxation at the notch tip, provided the best correlation between the notched and smooth bar behavior, although the fatigue data was not fully rationalized based on this simplified viscoplastic model of the stresses at the notch tip.Inclusion of a 90 sec dwell at peak load was found to dramatically decrease notch fatigue life. This result was shown to be consistent with a simple linear creep-fatigue damage rule, where creep damage dominated at low stresses and fatigue damage was more prevalent at higher stresses.
Villefort, Regina Furbino; Amaral, Marina; Pereira, Gabriel Kalil Rocha; Campos, Tiago Moreira Bastos; Zhang, Yu; Bottino, Marco Antonio; Valandro, Luiz Felipe; de Melo, Renata Marques
2017-01-01
Objective This study evaluated the effects of two grading zirconia techniques on the fatigue limit of 3-unit fixed dental prostheses (FDPs). Methods Presintered blocks of 3Y-TZP were milled to obtain sixty-nine 3-unit FDPs, which were divided into three groups (n = 23). The control group (CTL) was sintered and glazed following manufacturer’s instructuctions. The two experimental groups presintered FDPs received a surface silica/glass infiltration treatment before the sintering process. Silica sol-gel group (SSG) was graded by the sol-gel processing route, while the glass-zirconia-glass group (GZG) was graded by an enameling technique. Graded groups did not receive a glaze layer after sintering. All FDPs were then luted with a dual-curing resin cement on composite abutments, embedded in polyurethane and stored in water for five days. The initial load of the fatigue test was calculated based on the results of the monotonic testing applied on three specimens of each group. To determine the fatigue limit, 20 samples of each group were subjected to staircase testing (100,000 cycles/5 Hz). Results The fatigue limits (in Newtons) were CTL = 1607.27, SSG = 1824.31, and GZG = 2006.57, and the Dixon and Mood test indicated statistically significant differences among groups (95% confidence interval). Significance The infiltration of silica and glass on bulk zirconia, by two different grading methods, increased the fatigue limits of monolithic zirconia FDPs. PMID:28118929
Design of Linear Control System for Wind Turbine Blade Fatigue Testing
NASA Astrophysics Data System (ADS)
Toft, Anders; Roe-Poulsen, Bjarke; Christiansen, Rasmus; Knudsen, Torben
2016-09-01
This paper proposes a linear method for wind turbine blade fatigue testing at Siemens Wind Power. The setup consists of a blade, an actuator (motor and load mass) that acts on the blade with a sinusoidal moment, and a distribution of strain gauges to measure the blade flexure. Based on the frequency of the sinusoidal input, the blade will start oscillating with a given gain, hence the objective of the fatigue test is to make the blade oscillate with a controlled amplitude. The system currently in use is based on frequency control, which involves some non-linearities that make the system difficult to control. To make a linear controller, a different approach has been chosen, namely making a controller which is not regulating on the input frequency, but on the input amplitude. A non-linear mechanical model for the blade and the motor has been constructed. This model has been simplified based on the desired output, namely the amplitude of the blade. Furthermore, the model has been linearised to make it suitable for linear analysis and control design methods. The controller is designed based on a simplified and linearised model, and its gain parameter determined using pole placement. The model variants have been simulated in the MATLAB toolbox Simulink, which shows that the controller design based on the simple model performs adequately with the non-linear model. Moreover, the developed controller solves the robustness issue found in the existent solution and also reduces the needed energy for actuation as it always operates at the blade eigenfrequency.
Effects of oral administration of caffeine and D-ribose on mental fatigue.
Ataka, Suzuka; Tanaka, Masaaki; Nozaki, Satoshi; Mizuma, Hiroshi; Mizuno, Kei; Tahara, Tsuyoshi; Sugino, Tomohiro; Shirai, Tomoko; Kajimoto, Yoshitaka; Kuratsune, Hirohiko; Kajimoto, Osami; Watanabe, Yasuyoshi
2008-03-01
We examined the effects of administering two different candidate antifatigue substances, caffeine and D-ribose, on mental fatigue. In a double-blinded, placebo-controlled, three-way crossover design, 17 healthy volunteers were randomized to oral caffeine (200 mg/d), D-ribose (2000 mg/d), or placebo for 8 d. As fatigue-inducing mental tasks, subjects performed a 30-min Uchida-Kraepelin psychodiagnostic test and a 30-min advanced trail-making test on four occasions. During the tasks, the task performance of the caffeine group was better than that of the placebo group. However, after the fatigue-inducing tasks, although subjective perception of fatigue, motivation, or sleepiness was not significantly different, plasma branched-chain amino acid levels in the caffeine group were lower than those of the placebo group. Administration of D-ribose had no effect. Because plasma branched-chain amino acid levels are decreased by mental fatigue, these results suggest that administration of caffeine improved task performance through the enhancement of central nervous system activity without increasing the sensation of fatigue. However, further decreases in branched-chain amino acid levels indicate that caffeine might promote deeper fatigue than placebo. Unfortunately, research subsequent to our study design has shown that D-ribose dosing higher than we used is needed to see a clinical effect and therefore no conclusions can be made from this study as to the efficacy of D-ribose.
Hydraulic Fatigue-Testing Machine
NASA Technical Reports Server (NTRS)
Hodo, James D.; Moore, Dennis R.; Morris, Thomas F.; Tiller, Newton G.
1987-01-01
Fatigue-testing machine applies fluctuating tension to number of specimens at same time. When sample breaks, machine continues to test remaining specimens. Series of tensile tests needed to determine fatigue properties of materials performed more rapidly than in conventional fatigue-testing machine.
Fatigue Properties of Butt Welded Aluminum Alloy and Carbon Steel Joints by Friction Stirring
NASA Astrophysics Data System (ADS)
Okane, M.; Shitaka, T.; Ishida, M.; Chaki, T.; Yasui, T.; Fukumoto, M.
2017-05-01
The butt dissimilar joints of Al-Mg-Si alloy JIS A6063 and carbon steel JIS S45C by means of friction stir welding were prepared for investigating fatigue properties of the joints. The joining tool used has cemented carbide thread probe and a shoulder made of alloy tool steel. All the fatigue tests were carried out under a load-controlled condition with a load ratio R=0.1 in air at room temperature. From the experimental results, it was found that hardness near the interface in A6063 was lower than that of base material. Three types of fatigue fracture occurred even in case of same welding condition. The first one was fracture at boundary between the lower hardness region and base material in A6063, the second type was initiated in the stir zone by FSW process and the last one was fracture at interface. Fatigue strength in case of the second one was lower than others. Furthermore, to investigate the effect of heat treatment on fatigue properties of the dissimilar joints, fatigue tests were also carried out with using the specimens which were heat treated under the same condition to aging process in T6 treatment. Fatigue fracture was initiated at interface between A6063 and S45C in case of the heat treated specimen, but fatigue strength was improved approximately 25% as compared with that of the non-heat treated specimen.
Hall, Daniel L.; Antoni, Michael H.; Lattie, Emily G.; Jutagir, Devika R.; Czaja, Sara J.; Perdomo, Dolores; Lechner, Suzanne C.; Stagl, Jamie M.; Bouchard, Laura C.; Gudenkauf, Lisa M.; Traeger, Lara; Fletcher, MaryAnn; Klimas, Nancy G.
2015-01-01
Objective Persistent fatigue and depressive symptoms are both highly prevalent among patients with Chronic Fatigue Syndrome/Myalgic Encephalomyelitis (CFS/ME) as well as breast cancer survivors. This study aimed to assess and directly compare perceptions of fatigue as highly interfering in one’s daily functioning in both patient populations to better understand their relationships with depressed mood. Methods Participants were 95 female CFS/ME patients and 67 females who were approximately 5 years post-treatment for stage 0-III breast cancer presenting with clinically elevated fatigue severity. Self-report measures were obtained on participants’ fatigue-related interference in daily functioning and fatigue severity as well as depressed mood. Hierarchical regression was used to test effects controlling for relevant demographic, psychosocial, and medical covariates. Results CFS/ME patients endorsed greater depressed mood and fatigue interference than did fatigued breast cancer survivors, p’s<.001. These factors were significantly positively correlated among CFS/ME patients (β=.36, p<.001), but not the fatigued breast cancer survivors (β=.18, p=.19). Conclusions CFS/ME patients reported elevated fatigue symptoms and depression relative to fatigued breast cancer survivors. In the former group, greater depressed mood was highly and significantly associated with greater fatigue-related inference in daily activities. Potential targets for cognitive behavioral interventions are discussed. PMID:26180660
Jensen, Lauren; Dancisak, Michael; Korndorffer, James
2016-10-01
A localized, intermittent muscle-cooling protocol was implemented to determine cooling garment efficacy in reducing upper extremity muscular fatigue and tremor in novice ( n = 10) and experienced surgeons ( n = 9). Subjects wore a muscle-cooling garment while performing multiple trials of a forearm exercise and paired suturing task to induce muscular fatigue and exercise-induced tremor. A reduction in tremor amplitude and an extension in time to fatigue were expected with muscle cooling as compared with control trials. Each subject completed an intervention session (5°C cooling condition) and a control session (32°C or thermal neutral condition). A paired samples t test indicated that tremor amplitude was significantly reduced ( t [8] = 1.89458; p < 0.05) in experienced surgeons in two dimensions (up and down, and back and forth). Tremor amplitude was reduced in novice surgeons but the effect was not significant. Time to fatigue and suture time improved in both cohorts with muscle cooling, but the effect did not reach significance. Results from the pilot work suggest muscle cooling as an intervention for reduction of fatigue and tremor is very promising, warranting further investigation. Surgical specialties that require prolonged procedures might benefit more from this intervention.
NASA Technical Reports Server (NTRS)
Barrie, Robert L.; Gabb, Timothy P.; Telesman, Jack; Kantzos, Peter T.; Prescenzi, Anthony; Biles, Tiffany; Bonacuse, Peter J.
2005-01-01
The fatigue lives of modern powder metallurgy disk alloys can be reduced by over an order of magnitude by surface cracking at inherent non-metallic inclusions. The objective of this work was to study the effectiveness of shot peening in suppressing LCF crack initiation and growth at surface nonmetallic inclusions. Inclusions were carefully introduced at elevated levels during powder metallurgy processing of the nickel-base disk superalloy Udimet 720. Multiple strain-controlled fatigue tests were then performed on machined specimens at 427 and 650 C in peened and unpeened conditions. Analyses were performed to compare the low cycle fatigue lives and failure initiation sites as a function of inclusion content, shot peening, and fatigue conditions. A large majority of the failures in as-machined specimens with introduced inclusions occurred at cracks initiating from inclusions intersecting the specimen surface. The inclusions could reduce fatigue life by up to 100X. Large inclusions had the greatest effect on life in tests at low strain ranges and high strain ratios. Shot peening can be used to improve life in these conditions by reducing the most severe effects of inclusions.
(abstract) A Brief, Selective Review of Thermal Cycling Fatigue in Eutectic Tin-Lead Solder
NASA Technical Reports Server (NTRS)
Winslow, J. W.; Silveira, C. de
1993-01-01
This paper reviews selected parts of the current literature relevant to thermo-mechanical fatigue mechanisms in eutectic tin-lead solder, and suggests a general outline to account for some observed failures. The field is found to be complex. One recent experimental study finds some failure modes to be sensitive to joint geometry. Attempts to extrapolate from test environments to service environments have had only limited success. Much work remains to be done before fatigue failures in this material can be considered as under practical control.
Ratcheting fatigue behavior of Zircaloy-2 at room temperature
NASA Astrophysics Data System (ADS)
Rajpurohit, R. S.; Sudhakar Rao, G.; Chattopadhyay, K.; Santhi Srinivas, N. C.; Singh, Vakil
2016-08-01
Nuclear core components of zirconium alloys experience asymmetric stress or strain cycling during service which leads to plastic strain accumulation and drastic reduction in fatigue life as well as dimensional instability of the component. Variables like loading rate, mean stress, and stress amplitude affect the influence of asymmetric loading. In the present investigation asymmetric stress controlled fatigue tests were conducted with mean stress from 80 to 150 MPa, stress amplitude from 270 to 340 MPa and stress rate from 30 to 750 MPa/s to study the process of plastic strain accumulation and its effect on fatigue life of Zircaloy-2 at room temperature. It was observed that with increase in mean stress and stress amplitude accumulation of ratcheting strain was increased and fatigue life was reduced. However, increase in stress rate led to improvement in fatigue life due to less accumulation of ratcheting strain.
Failure Mechanisms and Damage Model of Ductile Cast Iron Under Low-Cycle Fatigue Conditions
NASA Astrophysics Data System (ADS)
Wu, Xijia; Quan, Guangchun; MacNeil, Ryan; Zhang, Zhong; Sloss, Clayton
2014-10-01
Strain-controlled low-cycle fatigue (LCF) tests were conducted on ductile cast iron (DCI) at strain rates of 0.02, 0.002, and 0.0002/s in the temperature range from room temperature to 1073 K (800 °C). A constitutive-damage model was developed within the integrated creep-fatigue theory (ICFT) framework on the premise of strain decomposition into rate-independent plasticity and time-dependent creep. Four major damage mechanisms: (i) plasticity-induced fatigue, (ii) intergranular embrittlement (IE), (iii) creep, and (iv) oxidation were considered in a nonlinear creep-fatigue interaction model which represents the overall damage accumulation process consisting of oxidation-assisted fatigue crack nucleation and propagation in coalescence with internally distributed damage ( e.g., IE and creep), leading to final fracture. The model was found to agree with the experimental observations of the complex DCI-LCF phenomena, for which the linear damage summation rule would fail.
Low-Cycle Fatigue Properties of P92 Ferritic-Martensitic Steel at Elevated Temperature
NASA Astrophysics Data System (ADS)
Zhang, Zhen; Hu, ZhengFei; Schmauder, Siegfried; Mlikota, Marijo; Fan, KangLe
2016-04-01
The low-cycle fatigue behavior of P92 ferritic-martensitic steel and the corresponding microstructure evolution at 873 K has been extensively studied. The test results of fatigue lifetime are consistent with the Coffin-Manson relationship over a range of controlled total strain amplitudes from 0.15 to 0.6%. The influence of strain amplitude on the fatigue crack initiation and growth has been observed using optical microscopy and scanning electron microscopy. The formation mechanism of secondary cracks is established according to the observation of fracture after fatigue process and there is an intrinsic relationship between striation spacing, current crack length, and strain amplitude. Transmission electron microscopy has been employed to investigate the microstructure evolution after fatigue process. It indicates the interaction between carbides and dislocations together with the formation of cell structure inhibits the cyclic softening. The low-angle sub-boundary elimination in the martensite is mainly caused by the cyclic stress.
NASA Astrophysics Data System (ADS)
Jeong, Chang Yeol; Nam, Soo Woo; Lim, Jong Dae
2003-04-01
A new life prediction function based on a model formulated in terms of stress relaxation during hold time under creep-fatigue conditions is proposed. From the idea that reduction in fatigue life with hold is due to the creep effect of stress relaxation that results in additional energy dissipation in the hysteresis loop, it is suggested that the relaxed stress range may be a creep-fatigue damage function. Creep-fatigue data from the present and other investigators are used to check the validity of the proposed life prediction equation. It is shown that the data satisfy the applicability of the life relation model. Accordingly, using this life prediction model, one may realize that all the Coffin-Manson plots at various levels of hold time in strain-controlled creep-fatigue tests can be normalized to make one straight line.
[Counseling in the prevention of fatigue in psychiatric nurses].
Greeff, M; Poggenpoel, M
1991-12-01
Nursing is a stressful activity and therefore it is necessary for nurses to develop effective coping mechanisms, or to strengthen existing ones in a healthy manner, in order to be capable of dealing with stress, arising from their personal and professional lives. It is, however, not solely stress itself which predisposes nurses to fatigue (physical, psychological and emotional exhaustion) but rather the chronic nature and excessive amount of stressors which place excessive demands on the energy resources and coping, mechanisms of nurses resulting in the ineffective handling of stress which in turn leads to the eventual development of fatigue. The detrimental results of this experience are, however, not confined to the nurse herself, but extends further to the patient and the organization. Thus, if fatigue is not controlled or dealt with, all parties and organizations concerned could suffer. This research covers the accompaniment function of the psychiatric nurse specialist in the prevention of fatigue in psychiatric nurses by strengthening their mental preparedness. As a possible solution to the experience of fatigue, a structured, accompanied program of three days was offered to a group of psychiatric nurses. The Solomon four group design was followed in order to eliminate influences on the subjects resulting from the completion of the self-evaluation scale as pre-test. The data which was obtained from the test results was statistically compared. Results showed that there was a definite decrease in the levels of fatigue experienced by the experimental group that received the structured accompanied programme, but no real change occurred in the control group that had merely been provided with relevant literature.(ABSTRACT TRUNCATED AT 250 WORDS)
Effect of Grinding and Multi-Stimuli Aging on the Fatigue Strength of a Y-TZP Ceramic.
Silvestri, Tais; Pereira, Gabriel Kalil Rocha; Guilardi, Luis Felipe; Rippe, Marilia Pivetta; Valandro, Luiz Felipe
2018-01-01
This study aimed to investigate the effect of grinding and multi-stimuli aging on the fatigue strength, surface topography and the phase transformation of Y-TZP ceramic. Discs were manufactured according to ISO-6872:2008 for biaxial flexure testing (diameter: 15 mm; thickness: 1.2 mm) and randomly assigned considering two factors "grinding" and "aging": C- control (as-sintered); CA- control + aging; G- ground; GA- ground + aging. Grinding was carried out with coarse diamond burs under water-cooling. Aging protocols consisted of: autoclave (134°C, 2 bars pressure, 20 hours), followed by storage for 365 days (samples were kept untouched at room temperature), and by mechanical cycling (106 cycles by 20 Hz under a load of 50% from the biaxial flexure monotonic tests). Flexural fatigue strengths (20,000 cycles; 6 Hz) were determined under sinusoidal cyclic loading using staircase approach. Additionally, surface topography analysis by FE-SEM and phase transformation analysis by X-ray Diffractometry were performed. Dixon and Mood methodology was used to analyze the fatigue strength data. Grinding promotes alterations of topographical pattern, while aging apparently did not alter it. Grinding triggered t-m phase transformation without impacting the fatigue strength of the Y-TZP ceramic; and aging promoted an intense t-m transformation that resulted in a toughening mechanism leading to higher fatigue strength for as-sintered condition, and a tendency of increase for ground condition (C < CA; G = GA). It concludes that grinding and aging procedures did not affect deleteriously the fatigue strength of the evaluated Y-TZP ceramic, although, it promotes surface topography alterations, except to aging, and t-m phase transformation.
The effect of muscle fatigue and low back pain on lumbar movement variability and complexity.
Bauer, C M; Rast, F M; Ernst, M J; Meichtry, A; Kool, J; Rissanen, S M; Suni, J H; Kankaanpää, M
2017-04-01
Changes in movement variability and complexity may reflect an adaptation strategy to fatigue. One unresolved question is whether this adaptation is hampered by the presence of low back pain (LBP). This study investigated if changes in movement variability and complexity after fatigue are influenced by the presence of LBP. It is hypothesised that pain free people and people suffering from LBP differ in their response to fatigue. The effect of an isometric endurance test on lumbar movement was tested in 27 pain free participants and 59 participants suffering from LBP. Movement variability and complexity were quantified with %determinism and sample entropy of lumbar angular displacement and velocity. Generalized linear models were fitted for each outcome. Bayesian estimation of the group-fatigue effect with 95% highest posterior density intervals (95%HPDI) was performed. After fatiguing %determinism decreased and sample entropy increased in the pain free group, compared to the LBP group. The corresponding group-fatigue effects were 3.7 (95%HPDI: 2.3-7.1) and -1.4 (95%HPDI: -2.7 to -0.1). These effects manifested in angular velocity, but not in angular displacement. The effects indicate that pain free participants showed more complex and less predictable lumbar movement with a lower degree of structure in its variability following fatigue while participants suffering from LBP did not. This may be physiological responses to avoid overload of fatigued tissue, increase endurance, or a consequence of reduced movement control caused by fatigue. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Vyletel, G. M.; Allison, J. E.; van Aken, D. C.
1995-12-01
The low-cycle and high-cycle fatigue behavior and cyclic response of naturally aged and overaged 2219/TiC/15p and unreinforced 2219 Al were investigated using plastic strain-controlled and stress-controlled testing. In addition, the influence of grain size on the particle-reinforced materials was examined. In both reinforced and unreinforced materials, the naturally aged conditions were cyclically unstable, exhibiting an initial hardening behavior followed by an extended region of cyclic stability and ultimately a softening region. The overaged reinforced material was cyclically stable for the plastic strains examined, while the overaged unreinforced material exhibited cyclic hardening at plastic strains greater than 2.5 × 10-4. Decreasing grain size of particle-reinforced materials modestly increased the cyclic flow stress of both naturally aged and overaged materials. Reinforced and unreinforced materials exhibited similar fatigue life behaviors; however, the reinforced and unreinforced naturally aged materials had superior fatigue lives in comparison to the overaged materials. Grain size had no effect on the fatigue life behavior of the particle-reinforced materials. The fatigue lives were strongly influenced by the presence of clusters of TiC particles and exogenous Al3Ti intermetallics.
Multi-mode evaluation of power-maximizing cross-flow turbine controllers
Forbush, Dominic; Cavagnaro, Robert J.; Donegan, James; ...
2017-09-21
A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performancemore » at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.« less
Multi-mode evaluation of power-maximizing cross-flow turbine controllers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forbush, Dominic; Cavagnaro, Robert J.; Donegan, James
A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performancemore » at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.« less
An Electromagnetic Tool for Damping and Fatigue Analysis
2004-03-01
Serway , Raymond A . Physics For Scientists & Engineers (3rd Edition). Philadelphia: Saunders College Publishing, 1990. 15. Kurtus, Ron...system was initially designed to reduce the time and manpower required to characterize damping treatments. It is based on a digitally controlled...the capability to study fatigue under a free boundary condition. The system consists of a test specimen suspended by a pendulum to closely
Kargarfard, Mehdi; Shariat, Ardalan; Ingle, Lee; Cleland, Joshua A; Kargarfard, Mina
2018-02-01
To assess the effects of an 8-week aquatic exercise training program on functional capacity, balance, and perceptions of fatigue in women with multiple sclerosis (MS). Randomized controlled design. Referral center of an MS society. Women (N=32; mean age ± SD, 36.4±8.2y) with diagnosed relapsing-remitting MS. After undergoing baseline testing by a neurologist, participants were allocated to either an intervention (aquatic training program, n=17) or a control group (n=15). The intervention consisted of an 8-week aquatic training program (3 supervised training sessions per week; session duration, 45-60min; 50%-75% estimated maximum heart rate). Six-minute walk test (6-MWT), balance (Berg Balance Scale [BBS]), and perceptions of fatigue (Modified Fatigue Impact Scale; [MFIS]) at baseline and after the 8-week intervention. Differences over time between the experimental and control groups were assessed by a 2×2 (group by time) repeated-measures analysis of variance. Thirty-two women completed the 8-week aquatic training intervention (experimental group, n=17; control group, n=15). All outcome measures improved in the experimental group: 6-MWT performance (pretest mean ± SD, 451±58m; posttest mean ± SD, 503±57m; P<.001); BBS (pretest mean ± SD, 53.59±1.70; posttest mean ± SD, 55.18±1.18; P<.001), and MFIS (pretest mean ± SD, 43.1±14.6; posttest mean ± SD, 32.8±5.9; P<.01). A significant group-by-time interaction was evident between the experimental and control groups for 6-MWT (P<.001, partial eta 2 [η p 2 ]=.551), BBS (P<.001, η p 2 =.423), and MFIS (P<.001, η p 2 =.679). Aquatic exercise training improved functional capacity, balance, and perceptions of fatigue in women with MS. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Application of millisecond pulsed laser for thermal fatigue property evaluation
NASA Astrophysics Data System (ADS)
Pan, Sining; Yu, Gang; Li, Shaoxia; He, Xiuli; Xia, Chunyang; Ning, Weijian; Zheng, Caiyun
2018-02-01
An approach based on millisecond pulsed laser is proposed for thermal fatigue property evaluation in this paper. Cyclic thermal stresses and strains within millisecond interval are induced by complex and transient temperature gradients with pulsed laser heating. The influence of laser parameters on surface temperature is studied. The combination of low pulse repetition rate and high pulse energy produces small temperature oscillation, while high pulse repetition rate and low pulse energy introduces large temperature shock. The possibility of application is confirmed by two thermal fatigue tests of compacted graphite iron with different laser controlled modes. The developed approach is able to fulfill the preset temperature cycles and simulate thermal fatigue failure of engine components.
Low cycle fatigue properties of MAR-M-246 Hf in hydrogen. [a cast nickel-base alloy
NASA Technical Reports Server (NTRS)
Warren, J. R.
1979-01-01
The transverse, low cycle fatigue properties were determined for directionally solidified and single crystal samples of a cast nickel-base alloy proposed for use in space propulsion systems in pure or partial high pressure hydrogen environments at elevated temperatures. The test temperature was 760 C (1400F) and the pressure of the gaseous hydrogen was 34.5 MPa (5000 psig). Low cycle fatique life was established by strain controlled testing using smooth specimens and a servohydraulic closed-loop test machine modified with a high pressure environmental chamber. Results and conclusions are discussed.
Fatigue Crack Growth Behavior of Gas Metal Arc Welded AISI 409 Grade Ferritic Stainless Steel Joints
NASA Astrophysics Data System (ADS)
Lakshminarayanan, A. K.; Shanmugam, K.; Balasubramanian, V.
2009-10-01
The effect of filler metals such as austenitic stainless steel, ferritic stainless steel, and duplex stainless steel on fatigue crack growth behavior of the gas metal arc welded ferritic stainless steel joints was investigated. Rolled plates of 4 mm thickness were used as the base material for preparing single ‘V’ butt welded joints. Center cracked tensile specimens were prepared to evaluate fatigue crack growth behavior. Servo hydraulic controlled fatigue testing machine with a capacity of 100 kN was used to evaluate the fatigue crack growth behavior of the welded joints. From this investigation, it was found that the joints fabricated by duplex stainless steel filler metal showed superior fatigue crack growth resistance compared to the joints fabricated by austenitic and ferritic stainless steel filler metals. Higher yield strength and relatively higher toughness may be the reasons for superior fatigue performance of the joints fabricated by duplex stainless steel filler metal.
Some aspects of thermomechanical fatigue of AISI 304L stainless steel: Part I. creep- fatigue damage
NASA Astrophysics Data System (ADS)
Zauter, R.; Christ, H. J.; Mughrabi, H.
1994-02-01
Thermomechanical fatigue (TMF) tests on the austenitic stainless steel AISI 304L have been conducted under “true≓ plastic-strain control in vacuum. This report considers the damage oc-curring during TMF loading. It is shown how the temperature interval and the phasing (in-phase, out-of-phase) determine the mechanical response and the lifetime of the specimens. If creep-fatigue interaction takes place during in-phase cycling, the damage occurs inside the ma-terial, leading to intergranular cracks which reduce the lifetime considerably. Out-of-phase cy-cling inhibits creep-induced damage, and no lifetime reduction occurs, even if the material is exposed periodically to temperatures in the creep regime. A formula is proposed which allows prediction of the failure mode, depending on whether creep-fatigue damage occurs or not. At a given strain rate, the formula is able to estimate the temperature of transition between pure fatigue and creep-fatigue damage.
Kara, Bilge; Küçük, Fadime; Poyraz, Esra Coşkuner; Tomruk, Melda Soysal; İdıman, Egemen
2017-01-01
The aim of our study is to examine effects of aerobic and Pilates exercises on disability, cognition, physical performance, balance, depression and fatigue in relapsing-remitting Multiple Sclerosis (MS) patients as compared to healthy controls. The subjects were divided as aerobic exercise (n = 26), Pilates (n = 9), and the healthy control group (n = 21). We used MSFC, physical performance, Berg balance scale, Beck depression scale, fatigue impact scale. All evaluations were performed before and after exercise training. There are statistically meaningful differences between Nine hole testing, PASAT 3, physical performance and fatique impact scale before and after aerobic exercise. Also we found significant difference for physical performance in the Pilates group. There are no significant differences in measures of fatique impact scale and depression between aerobic exercise group and the healthy controls after exercise. We found significant differences between Pilates and control group's after measurements except depression. There were significant differences between the Pilates and aerobic group for cognitive tests in favor of the Pilates group. Aerobic exercise and clinical Pilates exercises revealed moderate changes in levels of cognitive, physical performance, balance, depression, fatigue in MS patients.
Eisenlohr-Moul, Tory A; Burris, Jessica L; Evans, Daniel R
2013-12-01
A growing body of evidence suggests that chronic pain patients suffer from chronic self-regulatory fatigue: difficulty controlling thoughts, emotions, and behavior. Pain acceptance, which involves responding to pain and related experiences without attempts to control or avoid them (pain willingness), and pursuit of valued life activities regardless of pain (activity engagement) has been associated with various favorable outcomes in chronic pain patients, including better psychological functioning. The study presented here tested the hypotheses that pain acceptance is associated with less psychological distress, higher psychological well-being, and reduced self-regulatory fatigue in temporomandibular disorder (TMD) patients, particularly for those with longer pain duration. Cross-sectional data were provided by 135 TMD patients during an initial evaluation at a university-based tertiary orofacial pain clinic. Results of hierarchical linear regression models indicated that, controlling for pain severity, pain willingness is associated with less psychological distress and lower self-regulatory fatigue, and activity engagement is associated with greater psychological well-being. Furthermore, the effect of pain willingness on psychological distress was moderated by pain duration such that pain willingness was more strongly associated with less psychological distress in patients with longer pain duration; this moderating effect was fully mediated by self-regulatory fatigue. These findings suggest pain willingness may buffer against self-regulatory fatigue in those with longer pain duration, and such conservation of self-regulatory resources may protect against psychological symptoms.
A preliminary placebo-controlled crossover trial of fludrocortisone for chronic fatigue syndrome.
Peterson, P K; Pheley, A; Schroeppel, J; Schenck, C; Marshall, P; Kind, A; Haugland, J M; Lambrecht, L J; Swan, S; Goldsmith, S
1998-04-27
To provide a preliminary assessment of the efficacy and safety of fludrocortisone acetate treatment of chronic fatigue syndrome. A placebo-controlled, double-blind, random-allocation crossover trial of 6 weeks of fludrocortisone. An outpatient clinical trials unit. Twenty-five participants with chronic fatigue syndrome (mean age, 40 years; 19 [76%] women; mean duration of illness, 7.0 years) were recruited from a research and clinic registry. Five patients withdrew from the trial. All participants were scheduled to receive fludrocortisone acetate (0.1-0.2 mg) or a placebo for 6 weeks in each treatment. Self-administered questionnaires were completed at the beginning and end of each treatment arm that asked patients to rate the severity of their symptoms on a visual analogue scale. The Medical Outcomes Study 36-Item Short-Form Health Survey, a reaction time test, and a treadmill exercise test were used to assess functional status. Blood pressure, heart rate, and plasma norepinephrine levels were obtained at baseline. Blood pressure and heart rate were recorded at the end of the exercise test and monitored at all subsequent visits. At baseline, the study participants reported symptom severity greater than 5 for most symptoms, and all had evidence of marked functional impairments. No improvement was observed in the severity of any symptom or in any test of function for the 20 participants who completed both arms of the trial. Blood pressure and heart rate readings were unaffected by treatment, and plasma norepinephrine levels did not differ from those of a healthy control group. The incidence of adverse experiences was similar in the fludrocortisone and placebo arms of the trial. Low-dose fludrocortisone does not provide sufficient benefit to be evident in a preliminary blinded trial of unselected patients with chronic fatigue syndrome.
Thermomechanical fatigue life prediction for several solders
NASA Astrophysics Data System (ADS)
Wen, Shengmin
Since solder connections operate at high homologous temperature, solders are high temperature materials. This feature makes their mechanical behavior and fatigue phenomena unique. Based on experimental findings, a physical damage mechanism is introduced for solders. The mechanism views the damage process as a series of independent local damage events characterized by the failure of individual grains, while the structural damage is the eventual percolation result of such local events. Fine's dislocation energy density concept and Mura's microcrack initiation theory are adopted to derive the fatigue formula for an individual grain. A physical damage metric is introduced to describe the material with damage. A unified creep and plasticity constitutive model is adopted to simulate the mechanical behavior of solders. The model is cast into a continuum damage mechanics framework to simulate material with damage. The model gives good agreement with the experimental results of 96.5Pb-3.5Sn and 96.5Sn-3.5Ag solders under uniaxial strain-controlled cyclic loading. The model is convenient for implementation into commercial computational packages. Also presented is a fatigue theory with its failure criterion for solders based on physical damage mechanism. By introducing grain orientation into the fatigue formula, an m-N curve (m is Schmid factor) at constant loading condition is suggested for fatigue of grains with different orientations. A solder structure is defined as fatigued when the damage metric reaches a critical threshold, since at this threshold the failed grains may form a cluster and percolate through the structure according to percolation theory. Fatigue data of 96.5Pb-3.5Sn solder bulk specimens under various uniaxial tension tests were analyzed. Results show that the theory gives consistent predictions under broad conditions, while inelastic strain theory does not. The theory is anisotropic with no size limitation to its application, which could be suitable for anisotropic small-scale (micron or nano scale) solder joints. More importantly, the theory is materials science based so that the parameters of the fatigue formula can be worked out by testing of bulk specimens while the formula can be applicable to small-scale structures. The theory suggests metallurgical control in the manufacturing process to optimize the fatigue life of solder structures.
Driving Sodium/Potassium Pumps with an Oscillating Electric field: Effects on Muscle Fatigue
NASA Astrophysics Data System (ADS)
Lanes, Olivia; Bovyn, Matthew; Chen, Wei
2013-03-01
Dr. Chen has developed a technique called Synchronization Modulation, which has already been proven to be an effective tool in synchronizing and speeding up the sodium/potassium pumps in cell membranes. When synchronized, it is thought that these pumps are more efficient because they require less ATP. We hypothesized that if this was correct, this technique may be used to reduce muscle fatigue. To test our hypothesis, we had multiple test subjects hold a 15 lb weight for as long as they could while isolating the bicep muscle and applying an oscillating electric field. We compared the EMG data we took during these trials to the control, which was done the same way but without applying the electric field. To compare how fatigued subjects were, we did a Fast Fourier Transform on the first and last 10 seconds of each trial to measure the Fatigue Index. Our preliminary results suggest that the Fatigue Index decreased at a slower rate in the trials where the subject held the weight with Synchronization Modulation.
Heredia-Jimenez, Jose; Latorre-Roman, Pedro; Santos-Campos, Maria; Orantes-Gonzalez, Eva; Soto-Hermoso, Victor M
2016-03-01
Gait disorders in fibromyalgia patients affect several gait parameters and different muscle recruitment patterns. The aim of this study was to assess the gait differences observed during a six-minute walk test between fibromyalgia patients and healthy controls. Forty-eight women with fibromyalgia and 15 healthy women were evaluated. Fibromyalgia patients met the American College of Rheumatology criteria for fibromyalgia selected of an ambulatory care. Both patients and controls had a negative history of musculoskeletal disease, neurological disorders, and gait abnormalities. The 15 controls were healthy women matched to the patients in age, height and body weight. Spatio-temporal gait variables and the rate of perceived exertion during the six-minute walk test (all subjects) and Fibromyalgia Impact Questionnaire (fibromyalgia subjects) were evaluated. All walking sets on the GaitRITE were collected and the gait variables were selected at three stages during the six-minute walk test: two sets at the beginning, two sets at 3 min and two sets at the end of the test. In addition, the Fibromyalgia Impact Questionnaire was used for the fibromyalgia patients. Fibromyalgia patients showed a significant decrease in all spatio-temporal gait variables at each of the three stages and had a lower walk distance covered in the six-minute walk test and higher rate of perceived exertion. No correlations were found between the Fibromyalgia Impact Questionnaire and gait variables. The fibromyalgia and control subjects showed lower gait fatigue indices between the middle and last stages. Gait analysis during a six-minute walk test is a good tool to assess the fatigue and physical symptoms of patients with fibromyalgia. Copyright © 2016 Elsevier Ltd. All rights reserved.
Prefrontal Structure Varies as a Function of Pain Symptoms in Chronic Fatigue Syndrome.
van der Schaaf, Marieke E; De Lange, Floris P; Schmits, Iris C; Geurts, Dirk E M; Roelofs, Karin; van der Meer, Jos W M; Toni, Ivan; Knoop, Hans
2017-02-15
Chronic fatigue syndrome (CFS) is characterized by severe fatigue persisting for ≥6 months and leading to considerable impairment in daily functioning. Neuroimaging studies of patients with CFS have revealed alterations in prefrontal brain morphology. However, it remains to be determined whether these alterations are specific for fatigue or whether they relate to other common CFS symptoms (e.g., chronic pain, lower psychomotor speed, and reduced physical activity). We used magnetic resonance imaging to quantify gray matter volume (GMV) and the N-acetylaspartate and N-acetylaspartylglutamate/creatine ratio (NAA/Cr) in a group of 89 women with CFS. Building on previous reports, we tested whether GMV and NAA/Cr in the dorsolateral prefrontal cortex are associated with fatigue severity, pain, psychomotor speed, and physical activity, while controlling for depressive symptoms. We also considered GMV and NAA/Cr differences between patients with CFS and 26 sex-, age-, and education-matched healthy controls. The presence of pain symptoms was the main predictor of both GMV and NAA/Cr in the left dorsolateral prefrontal cortex of patients with CFS. More pain was associated with reduced GMVs and NAA/Cr, over and above the effects of fatigue, depressive symptoms, physical activity, and psychomotor speed. In contrast to previous reports and despite a large representative sample, global GMV did not differ between the CFS and healthy control groups. CFS, as diagnosed by Centers for Disease Control and Prevention criteria, is not a clinical entity reliably associated with reduced GMV. Individual variation in the presence of pain, rather than fatigue, is associated with neuronal alterations in the dorsolateral prefrontal cortex of patients with CFS. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Fatigue Test Design: Scenarios for Biaxial Fatigue Testing of a 60-Meter Wind Turbine Blade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Post, Nathan
Current practice in commercial certification of wind turbine blades is to perform separate flap and lead-lag fatigue tests. The National Renewable Energy Laboratory has been researching and evaluating biaxial fatigue testing techniques and demonstrating various options, typically on smaller-scale test articles at the National Wind Technology Center. This report evaluates some of these biaxial fatigue options in the context of application to a multimegawatt blade certification test program at the Wind Technology Testing Center in Charlestown, Massachusetts.
Kinetics and microscopic processes of long term fracture in polyethylene piping materials
NASA Astrophysics Data System (ADS)
Brown, N.; Lu, X.
1992-07-01
The report contains 9 completed works as follows: The Dependence of Slow Crack Growth in a Polyethylene Copolymer on Testing Temperature and Morphology; A Test of Slow Crack Growth Failure of PE Under Constant Load; Effect of Annealing on Slow Crack Growth in an Ethylene-Hexene Copolymer; The Fundamental Material Parameters that Govern Slow Crack Growth in Linear Polyethylene; Slow Crack Growth in Blends of HDPE and UHMWPE; The Mechanism of Fatigue Failure in a Polyethylene Copolymer; PENT Quality Control Test for PE Gas Pipes and Resins; International Round Robin Study of a Fatigue Test Approach to the Ranking of Polyethylene Pipe Material; and Proposed ASTM Specification for ASTM F17.40 Test Methods Committee.
Doerfler, R Eric; Goodfellow, Linda
2016-01-01
No study has tested the effectiveness of individualized cognitive behavioral therapy (CBT) interventions to reduce persistent nausea, pain, anxiety, and fatigue in patients on continuous antiretroviral therapy (ART). Our objective was to determine if CBT could reduce nausea, pain, anxiety, and fatigue in patients with HIV on ART. Men ages 40 to 56 years on ART (n = 18) at a suburban HIV clinic were randomly assigned to a control group or the CBT intervention. Usual adherence education and side-effect management were provided to both groups. Symptoms, health perception, medication adherence, and side-effect-reducing medication use were measured at four time points over 3 months. Participants in the intervention group rated usual fatigue and worst fatigue at 60 days, and nausea duration at 90 days significantly lower than controls (p < .05). Brief CBT training may reduce fatigue and nausea in patients with HIV undergoing ART. Copyright © 2016 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.
Carillon, Julie; Notin, Claire; Schmitt, Karine; Simoneau, Guy; Lacan, Dominique
2014-06-19
We aimed to investigate effects of superoxide dismutase (SOD)-melon concentrate supplementation on psychological stress, physical and mental fatigue in healthy people. A randomized, double-blind, placebo-controlled trial was performed on 61 people divided in two groups: active supplement (n = 32) and placebo (n = 29) for 12 weeks. Volunteers were given one small hard capsule per day. One capsule contained 10 mg of SOD-melon concentrate (140 U of SOD) and starch for the active supplement and starch only for the placebo. Stress and fatigue were evaluated using four psychometric scales: PSS-14; SF-36; Stroop tests and Prevost scale. The supplementation with SOD-melon concentrate significantly decreased perceived stress, compared to placebo. Moreover, quality of life was improved and physical and mental fatigue were reduced with SOD-melon concentrate supplementation. SOD-melon concentrate supplementation appears to be an effective and natural way to reduce stress and fatigue. trial approved by the ethical committee of Poitiers (France), and the ClinicalTrials.gov Identifier is NCT01767922.
Effects of Grain Size on the Fatigue Properties in Cold-Expanded Austenitic HNSs
NASA Astrophysics Data System (ADS)
Shin, Jong-Ho; Kim, Young-Deak; Lee, Jong-Wook
2018-05-01
Cold-expanded austenitic high nitrogen steel (HNS) was subjected to investigate the effects of grain size on the stress-controlled high cycle fatigue (HCF) as well as the strain-controlled low cycle fatigue (LCF) properties. The austenitic HNSs with two different grain sizes (160 and 292 μm) were fabricated by the different hot forging strain. The fine-grained (FG) specimen exhibited longer LCF life and higher HCF limit than those of the coarse-grained (CG) specimen. Fatigue crack growth testing showed that crack propagation rate in the FG specimen was the same as that in the CG specimen, implying that crack propagation rate did not affect the discrepancy of LCF life and HCF limit between two cold-expanded HNSs. Therefore, it was estimated that superior LCF and HCF properties in the FG specimen resulted from the retardation of the fatigue crack initiation as compared with the CG specimen. Transmission electron microscopy showed that the effective grain size including twin boundaries are much finer in the FG specimen than that in the CG specimen, which can give favorable contributions to strengthening.
Experimental studies on fatigue behavior of macro fiber composite (MFC) under mechanical loading
NASA Astrophysics Data System (ADS)
Pandey, Akash; Arockiarajan, A.
2016-04-01
Macro fiber Composite (MFC) finds its application in active control, vibration control and sensing elements. MFC can be laminated to surfaces or embedded in the structures to be used as an actuator and sensors. Due to its attractive properties and applications, it may be subjected to continuous loading, which leads to the deterioration of the properties. This study is focused on the fatigue lifetime of MFC under tensile and compressive loading at room temperature. Experiments were performed using 4 point bending setup, with MFC pasted at the center of the mild steel beam, to maintain constant bending stress along MFC. MFC is pasted using vacuum bagging technique. Sinusoidal loading is given to sample while maintaining R=0.13 (for tensile testing) and R=10 (for compressive testing). For d31 and d33 type of MFC, test was conducted for the strain values of 727 μ strain, 1400 μ strain, 1700 μ strain and 1900 μ strain for fatigue under tensile loading. For fatigue under compressive loading, both d33 and d31, was subjected to minimum strain of -2000 μ strain. Decrease in the slope of dielectric displacement vs. strain is the measure for the degradation. 10 percent decrease in the slope is set as the failure criteria. Experimental results show that MFC is very reliable below 1700 μ strain (R=0.13) at the room temperature.
Cumulative fatigue damage behavior of MAR M-247
NASA Technical Reports Server (NTRS)
Mcgaw, Michael A.; Halford, Gary R.; Kalluri, Sreeramesh
1991-01-01
The objective was to examine the room temperature fatigue and nonlinear cumulative fatigue damage behavior of the cast nickel-based superalloy, MAR M-247. The fatigue test matrix consisted of single-level, fully reversed fatigue experiments. Two series of tests were performed: one of the two baseline fatigue LCF (Low-Cycle Fatigue) life levels was used in the first loading block, and the HCF (High-Cycle Fatigue) baseline loading level was used in the second block in each series. For each series, duplicate tests were performed at each applied LCF life fraction.
NASA Technical Reports Server (NTRS)
Phillips, E. P.
1974-01-01
Specimens of Ti-6Al-4V titanium alloy sheet in the annealed and the solution-treated and aged heat-treatment condition were exposed outdoors at ambient and 560 K (550 F) temperatures to determine the effect of outdoor exposure on fatigue life. Effects of exposure were determined by comparing fatigue lives of exposed specimens to those of unexpected specimens. Two procedures for fatigue testing the exposed specimens were evaluated: (1) fatigue tests conducted outdoors by applying 1200 load cycles per week until failure occurred and (2) conventional fatigue tests (continuous cycling until failure occurred) conducted indoors after outdoor exposure under static load. The exposure period ranged from 9 to 28 months for the outdoor fatigue-test group and was 24 months for the static-load group. All fatigue tests were constant-amplitude bending of specimens containing a drilled hole (stress concentration factor of 1.6). The results of the tests indicate that the fatigue lives of solution-treated and aged specimens were significantly reduced by the outdoor exposure at 560 K but not by the exposure at ambient temperature. Fatigue lives of the annealed specimens were essentially unaffected by the outdoor exposure at either temperature. The two test procedures - outdoor fatigue test and indoor fatigue test after outdoor exposure - led to the same conclusions about exposure effects.
Effect of Heat Exposure on the Fatigue Properties of AA7050 Friction Stir Welds
NASA Astrophysics Data System (ADS)
White, B. C.; Rodriguez, R. I.; Cisko, A.; Jordon, J. B.; Allison, P. G.; Rushing, T.; Garcia, L.
2018-05-01
This work examines the effect of heat exposure on the subsequent monotonic and fatigue properties of friction stir-welded AA7050. Mechanical characterization tests were conducted on friction stir-welded specimens as-welded (AW) and specimens heated to 315 °C in air for 20 min. Monotonic testing revealed high joint efficiencies of 98% (UTS) in the AW specimens and 60% in the heat-damaged (HD) specimens. Experimental results of strain-controlled fatigue testing revealed shorter fatigue lives for the HD coupons by nearly a factor of four, except for the highest strain amplitude tested. Postmortem fractography analysis found similar crack initiation or propagation behavior between the AW and HD specimens; however, the failure locations for the AW were predominantly in the heat-affected zone, while the HD specimens also failed in the stir zone. Microhardness measurements revealed a relatively uniform strength profile in the HD group, accounting for the variety of failure locations observed. The differences in both monotonic and cyclic properties observed between the AW and HD specimens support the conclusion that the heat damage (315 °C at 20 min) acts as an over-aging and a quasi-annealing treatment.
Shobeiri, Fatemeh; Manoucheri, Behnaz; Parsa, Parisa; Roshanaei, Ghodratolah
2017-06-01
Increase of fatigue may lead to problems during pregnancy, delivery and post delivery. Sole reflexology is the application of pressure to areas on the feet. Reflexology is generally relaxing and may be an effective way to alleviate fatigue and stress. To investigate the effect of counselling and sole reflexology on fatigue in pregnant women, referred to the medical centers of Hamadan city, Iran. This study was a randomized clinical trial with three groups - Group A (counselling and reflexology), Group B (reflexology) and Group C (control) with pre and post intervention. A total of forty two pregnant women were selected for each group. Measurement tool was a 30 question standard checklist for fatigue assessment. For all three groups, an explanatory session was held to get their written consents and conduct a pretest. The intervention included five education sessions, twice a week about reflexology in the form of counselling and sole reflexology. The groups were assessed immediately after intervention. Data were analysed using IBM SPSS Statistics 20.0. To analyse the data, descriptive statistics, t test and ANOVA with repeated measures were used. In group A and group B, the mean score of fatigue severity after the intervention demonstrated a significant decrease (p<0.05); furthermore, after intervention, a significant difference was observed between the control and experimental groups in terms of fatigue severity (p<0.01). Based on the results of this study, counselling and sole reflexology significantly decreased fatigue in pregnant women. It is hoped that the results of this study can be used by all treatment groups and midwives for controlling and providing midwifery cares for pregnant women.
Shobeiri, Fatemeh; Parsa, Parisa; Roshanaei, Ghodratolah
2017-01-01
Introduction Increase of fatigue may lead to problems during pregnancy, delivery and post delivery. Sole reflexology is the application of pressure to areas on the feet. Reflexology is generally relaxing and may be an effective way to alleviate fatigue and stress. Aim To investigate the effect of counselling and sole reflexology on fatigue in pregnant women, referred to the medical centers of Hamadan city, Iran. Materials and Methods This study was a randomized clinical trial with three groups - Group A (counselling and reflexology), Group B (reflexology) and Group C (control) with pre and post intervention. A total of forty two pregnant women were selected for each group. Measurement tool was a 30 question standard checklist for fatigue assessment. For all three groups, an explanatory session was held to get their written consents and conduct a pretest. The intervention included five education sessions, twice a week about reflexology in the form of counselling and sole reflexology. The groups were assessed immediately after intervention. Data were analysed using IBM SPSS Statistics 20.0. To analyse the data, descriptive statistics, t test and ANOVA with repeated measures were used. Results In group A and group B, the mean score of fatigue severity after the intervention demonstrated a significant decrease (p<0.05); furthermore, after intervention, a significant difference was observed between the control and experimental groups in terms of fatigue severity (p<0.01). Conclusion Based on the results of this study, counselling and sole reflexology significantly decreased fatigue in pregnant women. It is hoped that the results of this study can be used by all treatment groups and midwives for controlling and providing midwifery cares for pregnant women. PMID:28764252
Severijns, Deborah; Van Geel, Fanny; Feys, Peter
2018-01-01
Motor fatigability is increasingly acknowledged in persons with MS (pwMS). It is unknown whether fatigability is generalized across upper limb muscles and relates to fatigue and perceived difficulties in upper limb use. This observational case-controlled study included twenty PwMS (median EDSS = 3, range 1.5-6.5) and twenty healthy controls who performed 30″ sustained maximal muscle contractions for index finger abduction, hand grip, elbow flexion and shoulder abduction. A static fatigue index (SFI) was calculated to assess motor fatigability for each muscle group. PwMS completed the Fatigue Severity Scale (FSS) and Modified Fatigue Index Scale (MFIS), to quantify severity and perceived impact of fatigue and the Manual Ability Measure (MAM-36) reflecting perceived difficulty in using the upper limbs. Comparisons between groups and muscles was made by t-tests. Associations between outcomes were calculated with correlation coefficients. Fatigue was highest in pwMS. PwMS showed preserved muscle strength and a greater motor fatigability in elbow flexors compared to healthy controls. SFI of elbow flexors and shoulder abductors were associated, and contributed to FSS and MFIS. SFI of elbow flexors and finger abductors predicted half of the variation in MAM-36. Increased motor fatigability was only present in elbow flexors of PwMS, indicating that expression of motor fatigability is not generalized. Fatigability was associated with perceived fatigue (impact) and daily life upper limb use. Results are preliminary given the small sample size with predominantly persons with mild MS. Copyright © 2017 Elsevier B.V. All rights reserved.
[Study on relationship between fatigue and work ability in chemistry workers].
Wu, Si-Ying; Wang, Mian-Zhen; Wang, Zhi-Ming; Lan, Ya-Jia
2005-01-01
Explore the relationship between fatigue and work ability in 976 chemistry workers. A test of fatigue and work ability was carried out with fatigue scale and work ability index (WAI) for 976 workers, other influence factors of the work ability (such as work environment, labor load, job factors) were investigated with questionnaire. (1) The frequency of fatigue of the unmarried workers was significantly lower than that of the married workers and other marital status workers, while the score of WAI of the unmarried was significantly higher than that of those( P < 0.05); (2) the frequency of fatigue of the mental workers was significantly lower than that of the mixed physical and mental workers, while the score of WAI of the mental workers was significantly higher than that of physical workers and mixed physical and mental workers ( P < 0.05); (3) compared with the workers free of fatigue, the other workers had lower WAI scores; (4) the fatigue score correlated negatively to the WAI score (r = -0.499, P < 0.01); (5) Cumulative odds model analysis showed that after controlling the other risk factors, fatigue was an important risk factor of work ability (OR = 4.005). Fatigue has affected work ability in chemistry workers, the frequency of fatigue is higher, the score of WAI is lower.
Lipinski, P; Barbas, A; Bonnet, A-S
2013-12-01
Because of its biocompatibility and high mechanical properties, the commercially pure grade 2 titanium (CPG2Ti) is largely used for fabrication of patient specific implants or hard tissue substitutes with complex shape. To avoid the stress-shielding and help their colonization by bone, prostheses with a controlled porosity are designed. The selective laser melting (SLM) is well adapted to manufacture such geometrically complicated structures constituted by struts with rough surfaces and relatively small diameters. Few studies were dedicated to characterize the fatigue properties of SLM processed samples and bulk parts. They followed conventional or standard protocols. The fatigue behavior of standard samples is very different from the one of porous raw structures. In this study, the SLM made "as built" (AB) and "heat treated" (HT) tubular samples were tested in fatigue. Wöhler curves were determined in both cases. The obtained endurance limits were equal to σD(AB)=74.5MPa and σD(HT)=65.7MPa, respectively. The heat treatment worsened the endurance limit by relaxation of negative residual stresses measured on the external surface of the samples. Modified Goodman diagram was established for raw specimens. Porous samples, based on the pattern developed by Barbas et al. (2012), were manufactured by SLM. Fatigue tests and finite element simulations performed on these samples enabled the determination of a simple rule of fatigue assessment. The method based on the stress gradient appeared as the best approach to take into account the notch influence on the fatigue life of CPG2Ti structures with a controlled porosity. The direction dependent apparent fatigue strength was found. A criterion based on the effective, or global, nominal stress was proposed taking into account the anisotropy of the porous structures. Thanks to this criterion, the usual calculation methods can be used to design bone substitutes, without a precise modelling of their internal fine porosity. © 2013 Elsevier Ltd. All rights reserved.
Corbett, Teresa; Walsh, Jane C; Groarke, AnnMarie; Moss-Morris, Rona; McGuire, Brian E
2016-01-01
Introduction Many post-treatment cancer survivors experience persistent fatigue that can disrupt attempts to resume normal everyday activities after treatment. Theoretical models that aim to explain contributory factors that initiate and sustain fatigue symptoms, or that influence the efficacy of interventions for cancer-related fatigue (CrF) require testing. Adjustment to fatigue is likely to be influenced by coping behaviours that are guided by the representations of the symptom. Objectives This paper describes the protocol for a pilot trial of a systematically and theoretically designed online intervention to enable self-management of CrF after cancer treatment. Methods and analysis This 2-armed randomised controlled pilot trial will study the feasibility and potential effectiveness of an online intervention. Participants will be allocated to either the online intervention (REFRESH (Recovery from Cancer-Related Fatigue)), or a leaflet comparator. Participants 80 post-treatment cancer survivors will be recruited for the study. Interventions An 8-week online intervention based on cognitive–behavioural therapy. Primary and secondary outcome measures The primary outcome is a change in fatigue as measured by the Piper Fatigue Scale (revised). Quality of life will be measured using the Quality of Life in Adult Survivors of Cancer Scale. Outcome measures will be collected at baseline, and at completion of intervention. Results The feasibility of trial procedures will be tested, as well as the effect of the intervention on the outcomes. Conclusions This study may lead to the development of a supportive resource to target representations and coping strategies of cancer survivors with CrF post-treatment. Setting Recruitment from general public in Ireland. Ethics and dissemination This trial was approved by the Research Ethics Committee at National University of Ireland Galway in January 2013. Trial results will be communicated in a peer-reviewed journal. Trial registration number ISRCTN55763085; Pre-results. PMID:27288384
NASA Astrophysics Data System (ADS)
Zhou, Yihui; Ou, Yu-Chen; Lee, George C.; O'Connor, Jerome S.
2010-09-01
Use of stainless reinforcing steel (SRS) in reinforced concrete (RC) structures is a promising solution to corrosion issues. However, for SRS to be used in seismic applications, several mechanical properties need to be investigated. These include specified and actual yield strengths, tensile strengths, uniform elongations and low-cycle fatigue behavior. Three types of SRSs (Talley S24100, Talley 316LN and Talley 2205) were tested and the results are reported in this paper. They were compared with the properties of A706 carbon reinforcing steel (RS), which is typical for seismic applications, and MMFX II, which is a high strength, corrosion resistant RS. Low-cycle fatigue tests of the RS coupons were conducted under strain control with constant amplitude to obtain strain life models of the steels. Test results show that the SRSs have slightly lower moduli of elasticity, higher uniform elongations before necking, and better low-cycle fatigue performance than A706 and MMFX II. All five types of RSs tested satisfy the requirements of the ACI 318 code on the lower limit of the tensile to yield strength ratio. Except Talley 2205, the other four types of RSs investigated meet the ACI 318 requirement that the actual yield strength does not exceed the specified yield strength by more than 18 ksi (124 MPa). Among the three types of SRSs tested, Talley S24100 possesses the highest uniform elongation before necking, and the best low-cycle fatigue performance.
Development of a high-frequency and large-stroke fatigue testing system for rubber
NASA Astrophysics Data System (ADS)
Chen, Gang; Wu, Hao; Gao, Jianwen; Lin, Qiang
2017-04-01
The limited capabilities of current fatigue testing machines have resulted in studies on the fatigue behavior of rubber under large-displacement amplitude and high frequency being very sparse. In this study, a fatigue testing system that can carry out large-displacement amplitude and high-frequency fatigue tests on rubber was developed using a moving magnet voice coil motor (MMVCM) actuator, with finite element analysis applied to analyze the thrust of the MMVCM actuator. The results of a series of cyclic tension tests conducted on vulcanized natural rubber specimens using the developed fatigue testing system verify that it has high precision, low noise, large-stroke, and high-frequency characteristics. Further, the load frame with the developed MMVCM actuator is feasible for material testing, especially for large-stroke and high-frequency fatigue tests.
Fatigue-Induced Balance Impairment in Young Soccer Players
Pau, Massimiliano; Ibba, Gianfranco; Attene, Giuseppe
2014-01-01
Context: Although balance is generally recognized to be an important feature in ensuring good performance in soccer, its link with functional performance remains mostly unexplored, especially in young athletes. Objective: To investigate changes in balance induced by fatigue for unipedal and bipedal static stances in young soccer players. Design: Crossover study. Setting: Biomechanics laboratory and outdoor soccer field. Patients or Other Participants: Twenty-one male soccer players (age = 14.5 ± 0.2 years, height = 164.5 ± 5.6 cm, mass = 56.8 ± 6.8 kg). Intervention(s): Static balance was assessed with postural-sway analysis in unipedal and bipedal upright stance before and after a fatigue protocol consisting of a repeated sprint ability (RSA) test (2 × 15-m shuttle sprint interspersed with 20 seconds of passive recovery, repeated 6 times). Main Outcome Measure(s): On the basis of the center-of-pressure (COP) time series acquired during the experimental tests, we measured sway area, COP path length, and COP maximum displacement and velocity in the anteroposterior and mediolateral directions. Results: Fatigue increased all sway values in bipedal stance and all values except COP velocity in the mediolateral direction in unipedal stance. Fatigue index (calculated on the basis of RSA performance) was positively correlated with fatigue/rest sway ratio for COP path length and COP velocity in the anteroposterior and mediolateral directions for nondominant single-legged stance. Conclusions: Fatigued players exhibited reduced performance of the postural-control system. Participants with better performance in the RSA test appeared less affected by balance impairment, especially in single-legged stance. PMID:24568227
Effect of Temper Condition on the Corrosion and Fatigue Performance of AA2219 Aluminum Alloy
NASA Astrophysics Data System (ADS)
Ghosh, Rahul; Venugopal, A.; Rao, G. Sudarshan; Ramesh Narayanan, P.; Pant, Bhanu; Cherian, Roy M.
2018-02-01
The effect of temper condition and corrosion on the fatigue behavior of alloy AA2219 has been investigated in different temper conditions (T87 and T851). Corrosion testing was performed by exposing the tensile specimens to 3.5% NaCl solution for different time periods, and the corrosion damage was quantified using a 3D profilometer. The exposure-tested specimens were subjected for fatigue testing at different stress levels, and the reduction in fatigue life was measured along with detailed fracture morphology variations. The results indicated that the alloy in both tempers suffers localized corrosion damage and the measured corrosion depth was 120 and 1200 µm, respectively, for T87 and T851 conditions. The loss in fatigue strength was found to be high for T851 (67%) when compared to that of T87 temper condition (58%) for a pre-corrosion time of 15 days. In both cases, fatigue crack initiation is associated with corrosion pits, which act as stress raisers. However, the crack propagation was predominantly transgranular for T87 and a mixed transgranular and intergranular fracture in the case of T851 temper condition. This was shown to be due to the heterogeneous microstructure due to the thermomechanical working and the delay in quench time imposed on the alloy forging in T851 temper condition. The findings in this paper present useful information for the selection of appropriate heat treatment condition to facilitate control of the corrosion behavior which is of great significance for their fatigue performance.
Trębacz, Hanna; Zdunek, Artur; Wlizło-Dyś, Ewa; Cybulska, Justyna; Pieczywek, Piotr
2015-10-16
The aim of this study was to test a hypothesis that fatigue-induced weakening of cortical bone was intensified in bone incubated in glucose and that this weakening is revealed in the microstructure and mechanical competence of the bone matrix. Cubic specimens of bovine femoral shaft were incubated in glucose solution (G) or in buffer (NG). One half of G samples and one half of NG were axially loaded in 300 cycles (30 mm/min) at constant deformation (F); the other half was a control (C). Samples from each group (GF, NGF, GC, NGC) were completely demineralized. Slices from demineralized samples were used for microscopic image analysis. A combined effect of glycation and fatigue on demineralized bone was tested in compression (10 mm/min). Damage of samples during the test was examined in terms of acoustic emission analysis (AE). During the fatigue procedure, resistance to loading in glycated samples decreased by 14.5% but only by 8.1% in nonglycated samples. In glycated samples fatigue resulted in increased porosity with pores significantly larger than in the other groups. Under compression, strain at failure in demineralized bone was significantly affected by glucose and fatigue. AE from demineralized bone matrix was considerably related to the largest pores in the tissue. The results confirm the hypothesis that the effect of fatigue on cortical bone tissue was intensified after incubation in glucose, both in the terms of the mechanical competence of bone tissue and the structural changes in the collagenous matrix of bone.
NASA Astrophysics Data System (ADS)
Chung, T. E.; Kalantary, M. R.; Faulkner, R. G.; Boutard, J.-L.
1992-09-01
Strain-controlled low cycle fatigue tests (with and without tensile hold) were performed on type 316L stainless steel over the temperature range 20-200°C. The results indicate that for strain ranges of less than 1%, the fatigue life was temperature independent. By contrast, for strain ranges of 1% or more, fatigue life decreased significantly as temperature was increased from 20 to approximately 50°C. It then increased with further increases in temperature until approximately 100°C and beyond when it became relatively temperature insensitive. Fatigue life at all temperatures was reduced with the superimposition of a speak tension hold of 50 s. A model based on the temperature-assisted diffusion of interstitial carbon atoms is proposed to explain the phenomenon.
Fatigue tests on big structure assemblies of concorde aircraft
NASA Technical Reports Server (NTRS)
Nguyen, V. P.; Perrais, J. P.
1972-01-01
Fatigue tests on structural assemblies of the Concorde supersonic transport aircraft are reported. Two main sections of the aircraft were subjected to pressure, mechanical load, and thermal static tests. The types of fatigue tests conducted and the results obtained are discussed. It was concluded that on a supersonic aircraft whose structural weight is a significant part of the weight analysis, many fatigue and static strength development tests should be made and fatigue and thermal tests of the structures are absolutely necessary.
Cognitive Fatigue Facilitates Procedural Sequence Learning.
Borragán, Guillermo; Slama, Hichem; Destrebecqz, Arnaud; Peigneux, Philippe
2016-01-01
Enhanced procedural learning has been evidenced in conditions where cognitive control is diminished, including hypnosis, disruption of prefrontal activity and non-optimal time of the day. Another condition depleting the availability of controlled resources is cognitive fatigue (CF). We tested the hypothesis that CF, eventually leading to diminished cognitive control, facilitates procedural sequence learning. In a two-day experiment, 23 young healthy adults were administered a serial reaction time task (SRTT) following the induction of high or low levels of CF, in a counterbalanced order. CF was induced using the Time load Dual-back (TloadDback) paradigm, a dual working memory task that allows tailoring cognitive load levels to the individual's optimal performance capacity. In line with our hypothesis, reaction times (RT) in the SRTT were faster in the high- than in the low-level fatigue condition, and performance improvement was higher for the sequential than the motor components. Altogether, our results suggest a paradoxical, facilitating impact of CF on procedural motor sequence learning. We propose that facilitated learning in the high-level fatigue condition stems from a reduction in the cognitive resources devoted to cognitive control processes that normally oppose automatic procedural acquisition mechanisms.
Krueger, Eddy; Popović-Maneski, Lana; Nohama, Percy
2018-02-01
A motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord-injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on the rectus femoris, vastus lateralis, and vastus medialis muscles. Data segments were decomposed into 11 frequency bands using a Cauchy wavelet transform. In the initial time interval (non-fatigued muscle), the power peak was concentrated in the 11.31 Hz frequency band. In the final interval (muscle fatigued) this peak shifted to lower frequencies (2 and 6 Hz frequency bands). The decreased frequency was most prominent during the last 4 s of the recordings. It was shown that MMG could be used as a real-time indicator of muscle fatigue during FES-induced isometric contraction of quadriceps; hence, MMG could be used in closed-loop control as a fatigue detector. Subsequent studies for non-isometric contractions could possibly lead to prediction of muscle fatigue before contractile failure during functional use of the muscle. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Fatigue crack growth in SA508-CL2 steel in a high temperature, high purity water environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerber, T.L.; Heald, J.D.; Kiss, E.
1974-10-01
Fatigue crack growth tests were conducted with 1 in. plate specimens of SA508-CL 2 steel in room temperature air, 550$sup 0$F air and in a 550$sup 0$F, high purity, water environment. Zero-tension load controlled tests were run at cyclic frequencies as low as 0.037 CPM. Results show that growth rates in the simulated Boiling Water Reactor (BWR) water environment are faster than growth rates observed in 550$sup 0$F air and these rates are faster than the room temperature rate. In the BWR water environment, lowering the cyclic frequency from 0.37 to 0.037 CPM caused only a slight increase in themore » fatigue crack growth rate. All growth rates measured in these tests were below the upper bound design curve presented in Section XI of the ASME Code. (auth)« less
The fatigue life prediction of aluminium alloy using genetic algorithm and neural network
NASA Astrophysics Data System (ADS)
Susmikanti, Mike
2013-09-01
The behavior of the fatigue life of the industrial materials is very important. In many cases, the material with experiencing fatigue life cannot be avoided, however, there are many ways to control their behavior. Many investigations of the fatigue life phenomena of alloys have been done, but it is high cost and times consuming computation. This paper report the modeling and simulation approaches to predict the fatigue life behavior of Aluminum Alloys and resolves some problems of computation. First, the simulation using genetic algorithm was utilized to optimize the load to obtain the stress values. These results can be used to provide N-cycle fatigue life of the material. Furthermore, the experimental data was applied as input data in the neural network learning, while the samples data were applied for testing of the training data. Finally, the multilayer perceptron algorithm is applied to predict whether the given data sets in accordance with the fatigue life of the alloy. To achieve rapid convergence, the Levenberg-Marquardt algorithm was also employed. The simulations results shows that the fatigue behaviors of aluminum under pressure can be predicted. In addition, implementation of neural networks successfully identified a model for material fatigue life.
The Effects of Hot Corrosion Pits on the Fatigue Resistance of a Disk Superalloy
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Telesman, Jack; Hazel, Brian; Mourer, David P.
2009-01-01
The effects of hot corrosion pits on low cycle fatigue life and failure modes of the disk superalloy ME3 were investigated. Low cycle fatigue specimens were subjected to hot corrosion exposures producing pits, then tested at low and high temperatures. Fatigue lives and failure initiation points were compared to those of specimens without corrosion pits. Several tests were interrupted to estimate the fraction of fatigue life that fatigue cracks initiated at pits. Corrosion pits significantly reduced fatigue life by 60 to 98 percent. Fatigue cracks initiated at a very small fraction of life for high temperature tests, but initiated at higher fractions in tests at low temperature. Critical pit sizes required to promote fatigue cracking were estimated, based on measurements of pits initiating cracks on fracture surfaces.
Subacromial impingement syndrome: An electromyographic study of shoulder girdle muscle fatigue.
Alizadehkhaiyat, Omid; Roebuck, Margaret M; Makki, Ahmed T; Frostick, Simon P
2018-02-01
Muscle fatigue affecting glenohumeral and/or scapular muscles is suggested as one of the contributing factors to the development of subacromial impingement syndrome (SAIS). Nonetheless, the fatigability of shoulder girdle muscles in association with the pathomechanics of SAIS has not been reported. This study aimed to measure and compare fatigue progression within the shoulder girdle musculature of patients and healthy controls. 75 participants including 39 patients (20 females; 19 males) and 36 healthy controls (15 females; 21 males) participated in the study. Study evaluated the progression of muscle fatigue in 15 shoulder girdle muscles by means of surface and fine-wire EMG during submaximal contraction of four distinct movements (abduction, flexion, internal and external rotation). Shoulder strength, subjective pain experience (McGill Pain Questionnaire), and psychological status (Hospital Anxiety and Depression Scale) were also assessed. The results were compared between patient and control groups according to the gender. Despite marked fatigue observed in the majority of muscles particularly during flexion and abduction at 90°, overall results indicated a lower tendency of fatigue progression in the impingement group across the tests (p < 0.05 - p < 0.001). Shoulder Strength, pain experience, and psychological status were significantly different between the two groups (P < .05). Lower tendency to fatigue progression in the impingement group can be attributed to the presence of fear avoidance and pain-related muscle inhibition, which in turn lead to adaptations in motor programme to reduce muscle recruitment and activation. The significantly higher levels of pain experience and anxiety/depression in the impingement group further support this proposition. Copyright © 2017 Elsevier Ltd. All rights reserved.
A comparative analysis of passive twin tube and skyhook MRF dampers for motorcycle front suspensions
NASA Astrophysics Data System (ADS)
Ahmadian, Mehdi; Gravatt, John
2004-07-01
A comparative analysis between conventional passive twin tube dampers and skyhook-controlled magneto-rheological fluid (MRF) dampers for motorcycle front suspensions is provided, based on single axis testing in a damper test rig and suspension performance testing in road trials. Performance motorcycles, while boasting extremely light suspension components and competition-ready performance, have an inherent weakness in comfort, as the suspension systems are designed primarily for racing purposes. Front suspension acceleration and shock loading transmit directly through the front suspension triple clamp into the rider's arms and shoulders, causing rapid fatigue in shoulder muscles. Magneto-rheological fluid dampers and skyhook control systems offer an alternative to conventional sport motorcycle suspensions - both performance and comfort can be combined in the same package. Prototype MRF dampers designed and manufactured specifically for this application require no more space than conventional twin tube designs while adding only 1.7 pounds total weight to the system. The MRF dampers were designed for high controllability and low power consumption, two vital considerations for a motorcycle application. The tests conducted include the dampers' force-velocity curve testing in a damper test rig and suspension performance based on damper position, velocity, and acceleration measurement. Damper test rig results show the MRF dampers have a far greater range of adjustability than the test vehicle's OEM dampers. Combined with a modified sky-hook control system, the MRF dampers can greatly decrease the acceleration and shock loading transmitted to the rider through the handlebars while contributing performance in manners such as anti-dive under braking. Triple clamp acceleration measurements from a variety of staged road conditions, such as sinusoidal wave inputs, will be compared to subjective test-rider field reports to establish a correlation between rider fatigue and the front suspension performance. This testing will be conducted on the OEM vehicle suspension, the passive MRF dampers, and the skyhook-controlled MRF damper front suspension. The results of this test will determine the viability of skyhook-controlled MRF damper systems on motorcycles for performance gain and fatigue reduction.
NASA Technical Reports Server (NTRS)
Bisagni, Chiara; Davila, Carlos G.; Rose, Cheryl A.; Zalameda, Joseph N.
2014-01-01
The durability and damage tolerance of postbuckled composite structures are not yet completely understood, and remain difficult to predict due to the nonlinearity of the geometric response and its interaction with local damage modes. A research effort was conducted to investigate experimentally the quasi-static and fatigue damage progression in a single-stringer compression (SSC) specimen. Three specimens were manufactured with a hat-stiffener, and an initial defect was introduced with a Teflon film embedded between one flange of the stringer and the skin. One of the specimens was tested under quasi-static compressive loading, while the remaining two specimens were tested by cycling in postbuckling. The tests were performed at the NASA Langley Research Center under controlled conditions and with instrumentation that allows a precise evaluation of the postbuckling response and of the damage modes. Three-dimensional digital image correlation VIC-3D systems were used to provide full field displacements and strains on the skin and the stringer. Passive thermal monitoring was conducted during the fatigue tests using an infrared camera that showed the location of the delamination front while the specimen was being cycled. The live information from the thermography was used to stop the fatigue tests at critical stages of the damage evolution to allow detailed ultrasonic scans.
Myoelectric manifestations of jaw elevator muscle fatigue and recovery in healthy and TMD subjects.
Castroflorio, T; Falla, D; Tartaglia, G M; Sforza, C; Deregibus, A
2012-09-01
The effects of muscle pain and fatigue on the control of jaw elevator muscles are not well known. Furthermore, the myoelectric manifestations of fatigue and recovery from fatigue in the masticatory muscles are not reported in literature. The main aims of this study were (i) to evaluate the possible use of surface electromyography (sEMG) as an objective measure of fatigue of the jaw elevator muscles, (ii) to compare the myoelectric manifestations of fatigue in the temporalis anterior and masseter muscles bilaterally, (iii) to assess recovery of the investigated muscles after an endurance test and (iv) to compare fatigue and recovery of the jaw elevator muscles in healthy subjects and patients with muscle-related temporomandibular disorders (TMD). The study was performed on twenty healthy volunteers and eighteen patients with muscle-related TMD. An intra-oral compressive-force sensor was used to measure the voluntary contraction forces close to the intercuspal position and to provide visual feedback of submaximal forces to the subject. Surface EMG signals were recorded with linear electrode arrays during isometric contractions at 20%, 40%, 60% and 80% of the maximum voluntary contraction force, during an endurance test and during the recovery phase. The results showed that (i) the slope of the mean power spectral frequency (MNF) and the initial average rectified value (ARV) could be used to monitor fatigue of the jaw elevators, (ii) the temporalis anterior and masseter muscle show the same myoelectric manifestations of fatigue and recovery and (iii) the initial values of MNF and ARV were lower in patients with muscle-related TMD. The assessment of myoelectric manifestations of fatigue in the masticatory muscles may assist in the clinical assessment of TMDs. © 2012 Blackwell Publishing Ltd.
Assessment of Low Cycle Fatigue Behavior of Powder Metallurgy Alloy U720
NASA Technical Reports Server (NTRS)
Gabb, Tomothy P.; Bonacuse, Peter J.; Ghosn, Louis J.; Sweeney, Joseph W.; Chatterjee, Amit; Green, Kenneth A.
2000-01-01
The fatigue lives of modem powder metallurgy disk alloys are influenced by variabilities in alloy microstructure and mechanical properties. These properties can vary as functions of variables the different steps of materials/component processing: powder atomization, consolidation, extrusion, forging, heat treating, and machining. It is important to understand the relationship between the statistical variations in life and these variables, as well as the change in life distribution due to changes in fatigue loading conditions. The objective of this study was to investigate these relationships in a nickel-base disk superalloy, U720, produced using powder metallurgy processing. Multiple strain-controlled fatigue tests were performed at 538 C (1000 F) at limited sets of test conditions. Analyses were performed to: (1) assess variations of microstructure, mechanical properties, and LCF failure initiation sites as functions of disk processing and loading conditions; and (2) compare mean and minimum fatigue life predictions using different approaches for modeling the data from assorted test conditions. Significant variations in life were observed as functions of the disk processing variables evaluated. However, the lives of all specimens could still be combined and modeled together. The failure initiation sites for tests performed at a strain ratio R(sub epsilon) = epsilon(sub min)/epsilon(sub max) of 0 were different from those in tests at a strain ratio of -1. An approach could still be applied to account for the differences in mean and maximum stresses and strains. This allowed the data in tests of various conditions to be combined for more robust statistical estimates of mean and minimum lives.
Wyller, Vegard B; Helland, Ingrid B
2013-02-07
Chronic Fatigue Syndrome (CFS) is characterized by severe impairment and multiple symptoms. Autonomic dysregulation has been demonstrated in several studies. We aimed at exploring the relationship between indices of autonomic cardiovascular control, the case definition from Centers for Disease Control and Prevention (CDC criteria), important clinical symptoms, and disability in adolescent chronic fatigue syndrome. 38 CFS patients aged 12-18 years were recruited according to a wide case definition (ie. not requiring accompanying symptoms) and subjected to head-up tilt test (HUT) and a questionnaire. The relationships between variables were explored with multiple linear regression analyses. In the final models, disability was positively associated with symptoms of cognitive impairments (p<0.001), hypersensitivity (p<0.001), fatigue (p=0.003) and age (p=0.007). Symptoms of cognitive impairments were associated with age (p=0.002), heart rate (HR) at baseline (p=0.01), and HR response during HUT (p=0.02). Hypersensitivity was associated with HR response during HUT (p=0.001), high-frequency variability of heart rate (HF-RRI) at baseline (p=0.05), and adherence to the CDC criteria (p=0.005). Fatigue was associated with gender (p=0.007) and adherence to the CDC criteria (p=0.04). In conclusion, a) The disability of CFS patients is not only related to fatigue but to other symptoms as well; b) Altered cardiovascular autonomic control is associated with certain symptoms; c) The CDC criteria are poorly associated with disability, symptoms, and indices of altered autonomic nervous activity.
NASA Astrophysics Data System (ADS)
Barlas, Thanasis; Pettas, Vasilis; Gertz, Drew; Madsen, Helge A.
2016-09-01
The application of active trailing edge flaps in an industrial oriented implementation is evaluated in terms of capability of alleviating design extreme loads. A flap system with basic control functionality is implemented and tested in a realistic full Design Load Basis (DLB) for the DTU 10MW Reference Wind Turbine (RWT) model and for an upscaled rotor version in DTU's aeroelastic code HAWC2. The flap system implementation shows considerable potential in reducing extreme loads in components of interest including the blades, main bearing and tower top, with no influence on fatigue loads and power performance. In addition, an individual flap controller for fatigue load reduction in above rated power conditions is also implemented and integrated in the general controller architecture. The system is shown to be a technology enabler for rotor upscaling, by combining extreme and fatigue load reduction.
The Boeing 747 fatigue integrity program
NASA Technical Reports Server (NTRS)
Spencer, M. M.
1972-01-01
The fatigue integrity program which was established to insure economic operations and to provide foundation data for inspection and maintenance is discussed. Significant features of the 747 fatigue integrity program are: (1) fatigue analyses which are continually updated to reflect design changes, fatigue test results, and static and flight load survey measurements; (2) material selection and detail design by using initial fatigue analyses, service experience, and testing; and (3) fatigue testing to check detail design quality and to verify the analyses, culminated by the test of a structurally complete airframe. Fatigue stress analyses were performed with the aid of experimental as well as analytical procedures. Extensive application was made of the stress severity factor, developed at Boeing, for evaluating peak stresses in complex joints. A frame of reference was established by families of structural fatigue performance curves (S-N curves) encompassing the range of materials and fatigue qualities anticipated for the 747 airplane design.
Intelligent walkers for the elderly: performance and safety testing of VA-PAMAID robotic walker.
Rentschler, Andrew J; Cooper, Rory A; Blasch, Bruce; Boninger, Michael L
2003-01-01
A walker that could help navigate and avoid collisions with obstacles could help reduce health costs and increase the quality of care and independence of thousands of people. This study evaluated the safety and performance of the Veterans Affairs Personal Adaptive Mobility Aid (VA-PAMAID). We performed engineering tests on the VA-PAMAID to determine safety factors, including stability, energy consumption, fatigue life, and sensor and control malfunctions. The VA-PAMAID traveled 10.9 km on a full charge and avoided obstacles while traveling at a speed of up to 1.2 m/s. No failures occurred during static stability, climatic, or fatigue testing. Some problems were encountered during obstacle climbing and sensor and control testing. The VA-PAMAID has good range, has adequate reaction time, and is structurally sound. Clinical trials are planned to compare the device to other low-technical adaptive mobility devices.
2011-01-01
Background Fatigue is a common complaint among elementary and junior high school students, and is known to be associated with reduced academic performance. Recently, we demonstrated that fatigue was correlated with decreased cognitive function in these students. However, no studies have identified cognitive predictors of fatigue. Therefore, we attempted to determine independent cognitive predictors of fatigue in these students. Methods We performed a prospective cohort study. One hundred and forty-two elementary and junior high school students without fatigue participated. They completed a variety of paper-and-pencil tests, including list learning and list recall tests, kana pick-out test, semantic fluency test, figure copying test, digit span forward test, and symbol digit modalities test. The participants also completed computerized cognitive tests (tasks A to E on the modified advanced trail making test). These cognitive tests were used to evaluate motor- and information-processing speed, immediate and delayed memory function, auditory and visual attention, divided and switching attention, retrieval of learned material, and spatial construction. One year after the tests, a questionnaire about fatigue (Japanese version of the Chalder Fatigue Scale) was administered to all the participants. Results After the follow-up period, we confirmed 40 cases of fatigue among 118 students. In multivariate logistic regression analyses adjusted for grades and gender, poorer performance on visual information-processing speed and attention tasks was associated with increased risk of fatigue. Conclusions Reduced visual information-processing speed and poor attention are independent predictors of fatigue in elementary and junior high school students. PMID:21672212
Mizuno, Kei; Tanaka, Masaaki; Fukuda, Sanae; Yamano, Emi; Shigihara, Yoshihito; Imai-Matsumura, Kyoko; Watanabe, Yasuyoshi
2011-06-14
Fatigue is a common complaint among elementary and junior high school students, and is known to be associated with reduced academic performance. Recently, we demonstrated that fatigue was correlated with decreased cognitive function in these students. However, no studies have identified cognitive predictors of fatigue. Therefore, we attempted to determine independent cognitive predictors of fatigue in these students. We performed a prospective cohort study. One hundred and forty-two elementary and junior high school students without fatigue participated. They completed a variety of paper-and-pencil tests, including list learning and list recall tests, kana pick-out test, semantic fluency test, figure copying test, digit span forward test, and symbol digit modalities test. The participants also completed computerized cognitive tests (tasks A to E on the modified advanced trail making test). These cognitive tests were used to evaluate motor- and information-processing speed, immediate and delayed memory function, auditory and visual attention, divided and switching attention, retrieval of learned material, and spatial construction. One year after the tests, a questionnaire about fatigue (Japanese version of the Chalder Fatigue Scale) was administered to all the participants. After the follow-up period, we confirmed 40 cases of fatigue among 118 students. In multivariate logistic regression analyses adjusted for grades and gender, poorer performance on visual information-processing speed and attention tasks was associated with increased risk of fatigue. Reduced visual information-processing speed and poor attention are independent predictors of fatigue in elementary and junior high school students. © 2011 Mizuno et al; licensee BioMed Central Ltd.
Hanken, Katrin; Bosse, Mona; Möhrke, Kim; Eling, Paul; Kastrup, Andreas; Antal, Andrea; Hildebrandt, Helmut
2016-01-01
Fatigue in multiple sclerosis (MS) patients appears to correlate with vigilance decrement as reflected in an increase in reaction time (RT) and errors with prolonged time-on-task. The aim of this study was to investigate whether anodal transcranial direct current stimulation (tDCS) over the right parietal or frontal cortex counteracts fatigue-associated vigilance decrement and subjective fatigue. In study I, a randomized double-blind placebo-controlled study, anodal tDCS (1.5 mA) was delivered to the right parietal cortex or the right frontal cortex of 52 healthy participants during the first 20 min of a 40-min lasting visual vigilance task. Study II, also a randomized double-blind placebo-controlled study, investigated the effect of anodal tDCS (1.5 mA) over the right parietal cortex in 46 MS patients experiencing cognitive fatigue. tDCS was delivered for 20 min before patients performed a 20-min lasting visual vigilance task. Study I showed that right parietal stimulation, but not right frontal stimulation, counteracts the increase in RT associated with vigilance decrement. Hence, only right parietal stimulation was applied to the MS patients in study II. Stimulation had a significant effect on vigilance decrement in mildly to moderately cognitively fatigued MS patients. Vigilance testing significantly increased the feeling of fatigue independent of stimulation. Anodal tDCS over the right parietal cortex can counteract the increase in RTs during vigilance performance, but not the increase in subjective fatigue. This finding is compatible with our model of fatigue in MS, suggesting a dissociation between the feeling and the behavioral characteristics of fatigue.
Effect of armodafinil on cognition in patients with HIV/AIDS and fatigue.
McElhiney, Martin; Rabkin, Judith; Van Gorp, Wilfred; Rabkin, Richard
2013-01-01
Fatigue and cognitive impairment are common in HIV+ adults and may occur independently or be causally linked. This study examined whether alleviation of fatigue with armodafinil in a placebo-controlled double-blind 4-week trial had an effect on cognitive function among those with and without mild neuropsychological impairment at baseline. Sixty-one patients completed a standard battery of neuropsychological tests at study entry and Week 4: A total of 33 were randomized to armodafinil and 28 to placebo. While there was a significant effect of active medication on fatigue, cognitive performance measured by a global change score did not differ between treatment groups, or in those on active treatment with or without mild neuropsychological impairment.
Assessment of microalloying effects on the high temperature fatigue behavior of NiAl
NASA Technical Reports Server (NTRS)
Noebe, R. D.; Lerch, B. A.; Rao, K. B. S.
1995-01-01
Binary NiAl suffers from a lack of strength and poor creep properties at and above 1000 K. Poor creep resistance in turn affects low cycle fatigue (LCF) lives at low strain ranges due to the additional interactions of creep damage. One approach for improving these properties involved microalloying with either Zr or N. As an integral part of a much larger alloying program the low cycle fatigue behavior of Zr and N doped nickel aluminides produced by extrusion of prealloyed powders has been investigated. Strain controlled LCF tests were performed in air at 1000 K. The influence of these microalloying additions on the fatigue life and cyclic stress response of polycrystalline NiAl are discussed.
The effect of notches and pits on corrosion fatigue strength
NASA Astrophysics Data System (ADS)
Tatner, Ian
An investigation has been undertaken to examine the fatigue behaviour of two martensitic steels in air and aggressive environments. The steels studied are, 18% Ni marageing steel and FV520B, the later being a stainless steel turbine blade material and the former being a marageing steel that suffers general corrosion in mild environments. Both steels were heat treated to give similar tensile strength.The design and manufacture of an autoclave allowed push-pull fatigue tests to be conducted in aggressive environments at elevated temperatures.Corrosion potential was monitored using a three electrode cell and was controlled during testing. Base-line fatigue tests were conducted with a range of constant corrosion potentials, using both notched and plain FV520B specimens. In addition fatigue tests with pulsed corrosion potential were performed to asses the effect of transient corrosion conditions on the corrosion fatigue strength. The pulsed tests were designed to simulate service transients in the oxygen content and general chemical hostility in the condensing steam environment during start-up and shut down of the steam turbine.Post test examination of fractured samples was performed using Scanning Electron Microscopy (SEM) and optical microscope techniques. The fractography results were used to quantify microstructural and fracture features of the steels.A model based on the size and geometry of the initial corrosion pitting has been proposed to asses the fatigue life of FV520B in an aggressive environment.The effect of pitting on the corrosion fatigue strength of FV520B has been modelled using linear elastic fracture mechanics (LEFM) type approach. The model has shown a good correlation between predicted fatigue lives with experimental results.The results suggest that the fatigue life is governed by the mechanical stress concentrating effect of the pits rather than the electrochemical damage caused by the environment.Finite Element Analysis (FEA) of the notch allowed calculation of the elastic stress intensity factor (K[t]) for the specimen geometry used. The experimental results together with numerical results of FEA were used to calculate of the notch strength reduction factor (K[f]) for the material. This has been used to derive the notch sensitivity factors (q) for both materials.The results of fatigue tests in air showed that although both materials have similar tensile strength their plain fatigue strengths are different. The sensitivity of the fatigue strength to notches was also found to be significantly different. The marageing steel showed a higher sensitivity to a notch than the FV520B.An empirical model has been proposed to quantify the notch sensitivity and the effects of various microstructural features on the fatigue strength. A model has been developed to predict the serviceable life of a peak hardened FV520B turbine blade subjected to aggressive low load conditions during start-up and non-aggressive high load conditions during continual running. The model is based on the conclusions suggested in the work of a threshold stress intensity factor being reached where a fatigue crack will grow from a corrosion pit at the root of a notch. The model is then used to highlight the life reduction caused to steam turbine blades due to increased numbers of start-up cycles.
Laser thermal shock and fatigue testing system
NASA Astrophysics Data System (ADS)
Fantini, Vincenzo; Serri, Laura; Bianchi, P.
1997-08-01
Thermal fatigue consists in repeatedly cycling the temperature of a specimen under test without any other constraint and stopping the test when predefined damage aspects. The result is a lifetime in terms of number of cycles. The parameters of the thermal cycle are the following: minimum and maximum temperature, time of heating, of cooling and time at high or at low temperature. When the temperature jump is very big and fast, phenomena of thermal shock can be induced. Among the numerous techniques used to perform these tests, the laser thermal fatigue cycling is very effective when fast heating of small and localized zones is required. That's the case of test performed to compare new and repaired blades of turbogas machines or components of combustion chambers of energy power plants. In order to perform these tests a thermal fatigue system, based on 1 kW Nd-YAG laser as source of heating, has been developed. The diameter of the heated zone of the specimen irradiated by the laser is in the range 0.5 - 20 mm. The temperatures can be chosen between 200 degree(s)C and 1500 degree(s)C and the piece can be maintained at high and/or low temperature from 0 s to 300 s. Temperature are measured by two sensors: a pyrometer for the high range (550 - 1500 degree(s)C) and a contactless thermocouple for the low range (200 - 550 degree(s)C). Two different gases can be blown on the specimen in the irradiated spot or in sample backside to speed up cooling phase. A PC-based control unit with a specially developed software performs PID control of the temperature cycle by fast laser power modulation. A high resolution vision system of suitable magnification is connected to the control unit to detect surface damages on the specimen, allowing real time monitoring of the tested zone as well as recording and reviewing the images of the sample during the test. Preliminary thermal fatigue tests on flat specimens of INCONEL 738 and HAYNES 230 are presented. IN738 samples, laser cladded by powder of the same material to simulate the refurbishing of a damaged turbine blade after long-term operation, are compared to the parents. Lifetimes are decreasing when high temperature of the cycle is increased and shorter lifetimes of repaired pieces have been found. Laser and TIG welding on HY230 specimens are compared to the parent. Parent and repaired samples have no evidence of cracks after 1500 thermal cycles between 650 and 1000 degree(s)C.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skochko, G.W.; Herrmann, T.P.
Axial load cycling fatigue tests of threaded fasteners are useful in determining fastener fatigue failure or design properties. By using appropriate design factors between the failure and design fatigue strengths, such tests are used to establish fatigue failure and design parameters of fasteners for axial and bending cyclic load conditions. This paper reviews the factors which influence the fatigue strength of low Alloy steel threaded fasteners, identifies those most significant to fatigue strength, and provides design guidelines based on the direct evaluation of fatigue tests of threaded fasteners. Influences on fatigue strength of thread manufacturing process (machining and rolling ofmore » threads), effect of fastener membrane and bending stresses, thread root radii, fastener sizes, fastener tensile strength, stress relaxation, mean stress, and test temperature are discussed.« less
Analysis of fatigue on surface course using dissipated energy approach
NASA Astrophysics Data System (ADS)
Michael; Setyawan, A.; Pramesti, F. P.
2018-03-01
As an important transportation infrastructure, pavement is subjected to repeated vehicle loads that may cause fatigue, which often leads to cracking. The point when this cracking initiates can be determined from the energy dissipated during the loading. This research investigates fatigue in Adi Soemarmo Airport mix-design using bitumen Pen 60/70 + EVA (Ethyl Vinyl Acetate) polymer. An Indirect Tensile Fatigue Test (ITFT) was conducted using stress-controlled loading mode to determine its fatigue life. The stress levels were 500, 600, and 700 kPa, while the loading frequency and the temperature were 10 Hz and 20°C, respectively. The test exhibits strain levels for each loading cycle, which were used to determine the dissipated energy (DE). The result indicates that the DE increases when the number of loading cycles increases, due to progress of the strain levels. The values of DE are 7122.8, 8614.3, and 2654.9 J/m3 for loading levels of 500, 600, and 700 kPa, respectively, whereas the failure points for stress levels of 500, 600, and 700 kPa are 8171, 5161, and 841 cycles, respectively. Thus, the longer the time until the pavement failure point is reached (fatigue life), the greater the amount of energy that is dissipated.
Fatigue Behavior of Ultrafine-Grained 5052 Al Alloy Processed Through Different Rolling Methods
NASA Astrophysics Data System (ADS)
Yogesha, K. K.; Joshi, Amit; Jayaganthan, R.
2017-05-01
In the present study, 5052 Al alloy was processed through different rolling methods to obtain ultrafine grains and its high-cycle fatigue behavior were investigated. The solution-treated Al-Mg alloys (AA 5052) were deformed through different methods such as cryorolling (CR), cryo groove rolling (CGR) and cryo groove rolling followed by warm rolling (CGW), up to 75% thickness reduction. The deformed samples were subjected to mechanical testing such as hardness, tensile and high-cycle fatigue (HCF) test at stress control mode. The CGW samples exhibit better HCF strength when compared to other conditions. The microstructure of the tested samples was characterized by optical microscopy, SEM fractography and TEM to understand the deformation behavior of deformed Al alloy. The improvement in fatigue life of CR and CGR samples is due to effective grain refinement, subgrain formations, and high dislocation density observed in the heavily deformed samples at cryogenic condition as observed from SEM and TEM analysis. However, in case of CGW samples, formation of nanoshear bands accommodates the applied strain during cyclic loading, thereby facilitating dislocation accumulation along with subgrain formations, leading to the high fatigue life. The deformed or broken impurity phase particles found in the deformed samples along with the precipitates that were formed during warm rolling also play a prominent role in enhancing the fatigue strength. These tiny particles hindered the dislocation movement by effectively pinning it at grain boundaries, thereby improving the resistance of crack propagation under cyclic load.
NASA Astrophysics Data System (ADS)
Kramer, Hendrik; Klein, Marcus; Eifler, Dietmar
Conventional methods to characterize the fatigue behavior of metallic materials are very time and cost consuming. That is why the new short-time procedure PHYBALCHT was developed at the Institute of Materials Science and Engineering at the University of Kaiserslautern. This innovative method requires only a planar material surface to perform cyclic force-controlled hardness indentation tests. To characterize the cyclic elastic-plastic behavior of the test material the change of the force-indentation-depth-hysteresis is plotted versus the number of indentation cycles. In accordance to the plastic strain amplitude the indentation-depth width of the hysteresis loop is measured at half minimum force and is called plastic indentation-depth amplitude. Its change as a function of the number of cycles of indentation can be described by power-laws. One of these power-laws contains the hardening-exponentCHT e II , which correlates very well with the amount of cyclic hardening in conventional constant amplitude fatigue tests.
Micromechanical Fatigue Visco-Damage Model for Short Glass Fiber Reinforced Polyamide-66
NASA Astrophysics Data System (ADS)
Despringre, N.; Chemisky, Y.; Robert, G.; Meraghni, F.
This work presents a micromechanical fatigue damage model developed for short glass fiber reinforced PA66. It has been developed to predict the high cycle fatigue behavior of PA66/GF30. The model is based on an extended Mori-Tanaka method which includes coated inclusions, matrix viscoelasticity and the evolution of micro-scale damage. The developed model accounts for the nonlinear matrix viscoelasticity and the reinforcement orientation. The description of the damage processes is based on the experimental investigation of damage mechanisms previously performed through in-situ SEM tests and X-ray micro-computed tomography observations. Damage chronologies have been proposed involving three different processes: interface debonding/coating, matrix micro-cracking and fiber breakages. Their occurrence strongly depends on the microstructure and the relative humidity. Each damage mechanism is introduced through an evolution law coupled to local stress fields. The developed model is implemented using a UMAT subroutine. Its experimental validation is achieved under stress or strain controlled fatigue tests.
Villafañe, Jorge H; Gobbo, Massimiliano; Peranzoni, Matteo; Naik, Ganesh; Imperio, Grace; Cleland, Joshua A; Negrini, Stefano
2016-09-01
This systematic literature review aimed at examining the validity and applicability in everyday clinical rehabilitation practise of methods for the assessment of back muscle fatiguability in patients with chronic non-specific low back pain (CNSLBP). Extensive research was performed in MEDLINE, Cumulative Index of Nursing and Allied Health Literature (CINAHL), Embase, Physiotherapy Evidence Database (PEDro) and Cochrane Central Register of Controlled Trials (CENTRAL) databases from their inception to September 2014. Potentially relevant articles were also manually looked for in the reference lists of the identified publications. Studies examining lumbar muscle fatigue in people with CNSLBP were selected. Two reviewers independently selected the articles, carried out the study quality assessment and extracted the results. A modified Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) scale was used to evaluate the scientific rigour of the selected works. Twenty-four studies fulfilled the selection criteria and were included in the systematic review. We found conflicting data regarding the validity of methods used to examine back muscle fatigue. The Biering-Sorensen test, performed in conjunction with surface electromyography spectral analysis, turned out to be the most widely used and comparatively, the most optimal modality currently available to assess objective back muscle fatigue in daily clinical practise, even though critical limitations are discussed. Future research should address the identification of an advanced method for lower back fatigue assessment in patients with CNSLBP which, eventually, might provide physical therapists with an objective and reliable test usable in everyday clinical practise. Implications for Rehabilitation Despite its limitations, the Biering-Sorensen test is currently the most used, convenient and easily available fatiguing test for lumbar muscles. To increase validity and reliability of the Biering-Sorensen test, concomitant activation of synergistic muscles should be taken into account. Pooled mean frequency and half-width of the spectrum are currently the most valid electromyographic parameters to assess fatigue in chronic non-specific low back pain. Body mass index, grading of pain and level of disability of the study population should be reported to enhance research quality.
Active tower damping and pitch balancing - design, simulation and field test
NASA Astrophysics Data System (ADS)
Duckwitz, Daniel; Shan, Martin
2014-12-01
The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine.
Ho, Rainbow T H; Chan, Jessie S M; Wang, Chong-Wen; Lau, Benson W M; So, Kwok Fai; Yuen, Li Ping; Sham, Jonathan S T; Chan, Cecilia L W
2012-10-01
Chronic fatigue is common in the general population. Complementary therapies are often used by patients with chronic fatigue or chronic fatigue syndrome to manage their symptoms. This study aimed to assess the effect of a 4-month qigong intervention program among patients with chronic fatigue or chronic fatigue syndrome. Sixty-four participants were randomly assigned to either an intervention group or a wait list control group. Outcome measures included fatigue symptoms, physical functioning, mental functioning, and telomerase activity. Fatigue symptoms and mental functioning were significantly improved in the qigong group compared to controls. Telomerase activity increased in the qigong group from 0.102 to 0.178 arbitrary units (p < 0.05). The change was statistically significant when compared to the control group (p < 0.05). Qigong exercise may be used as an alternative and complementary therapy or rehabilitative program for chronic fatigue and chronic fatigue syndrome.
Kim, Ja Ok; Kim, In Sook
2012-10-01
This study was done to examine the effects of aroma self-foot reflexology massage on stress and immune responses and fatigue in middle-aged women in rural areas. The study was a nonequivalent control group pre-post test design. The participants were 52 middle-aged women from rural areas of which 26 were assigned to the experimental group and 26 to the control group. Data were collected from July to September, 2011 and analyzed using SPSS Win 17.0 version program. The intervention was conducted 3 times a week for six weeks. There were significant differences in reported perceived stress, systolic blood pressure, diastolic blood pressure and fatigue between the two groups. However, the issue of salivary cortisol and immune response were not significant. Aroma self-foot reflexology massage can be utilized as an effective intervention for perceived stress, systolic blood pressure, diastolic blood pressure and fatigue in middle-aged woman in rural areas.
NASA Astrophysics Data System (ADS)
Maday, Marie-Françoise
2000-12-01
The low cycle fatigue (LCF) behaviour of F82H modified steel with three different degrees of hardness produced by specific thermal treatments has been investigated at 240°C under load control, in oxygen-free lithiated solutions containing either no or 2 ppm dissolved hydrogen. In all cases, it was found that the aqueous environments reduced the fatigue life of the material and promoted fracture modes different from those observed in air tests; the fracture modes comprised intergranular and transgranular quasi-cleavage separations as well as microvoid coalescence, which depended on material conditions and water chemistry. All these features were ascribed to a hydrogen-assisted-cracking (HAC) phenomenon, as the basic mechanism for controlling the fatigue behaviour of various F82H heats in lithiated solutions. The observed differences in HAC paths are discussed from the standpoint of material microstructural and substructural parameters.
An optical motion measuring system for laterally oscillated fatigue tests
NASA Technical Reports Server (NTRS)
Tripp, John S.; Tcheng, Ping; Murri, Gretchen B.; Sharpe, Scott
1993-01-01
This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.
AlShwaimi, E
2018-01-01
To compare the cyclic fatigue properties of a novel file made using controlled memory Ni-Ti technology with those of files made from M-wire. Twelve files with similar cross-sectional geometry and tip size from each of the following groups were tested: Proflexendo made from CMT (PE; size 30 0.04; Nexden, Houston, Tx, USA), ProFile Vortex made from M-wire (PV; size 30 0.04; Dentsply Tulsa Dental, Tulsa, OK, USA) and ProTaper Universal made from regular alloy (PU; F3; Dentsply Tulsa Dental). A custom-made cyclic fatigue device was made to evaluate the total number of cycles to failure for each system. A scanning electron microscope (SEM) was used to examine the fractured surfaces of the fragments. The arithmetic means and standard deviations were calculated for the total number of cycles to failure. One-way analysis of variance was used to compare the mean cyclic failure amongst the three groups. Post hoc Tukey's test was performed to compare the difference of the means between the groups at a significance level of P < 0.05. Proflexendo had a significantly greater resistance to cyclic fatigue compared to other systems (P < 0.001). Proflexendo files were able to withstand 500% more cycles to fracture when compared to ProFile Vortex files. Manufacturing technique had a significant impact on the resistance to cyclic fatigue. Proflexendo files made from controlled memory Ni-Ti technology had the highest number of cycles to failure compared to ProFile Vortex made from M-wire files with similar taper and tip size. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Effect of Different Levels of Localized Muscle Fatigue on Knee Position Sense
Gear, William S.
2011-01-01
There is little information available regarding how proprioceptive abilities decline as the amount of exertion increases during exercise. The purpose of this study was to determine the role of different levels of fatigue on knee joint position sense. A repeated measures design was used to examine changes in active joint reposition sense (AJRS) prior to and following three levels of fatigue. Eighteen participants performed knee extension and flexion isokinetic exercise until torque output was 90%, 70%, or 50% of the peak hamstring torque for three consecutive repetitions. Active joint reposition sense at 15, 30, or 45 degrees was tested following the isokinetic exercise session. Following testing of the first independent measure, participants were given a 20 minute rest period. Testing procedures were repeated for two more exercise sessions following the other levels of fatigue. Testing of each AJRS test angle was conducted on three separate days with 48 hours between test days. Significant main effect for fatigue was indicated (p = 0.001). Pairwise comparisons indicated a significant difference between the pre-test and following 90% of peak hamstring torque (p = 0.02) and between the pre-test and following 50% of peak hamstring torque (p = 0.02). Fatigue has long been theorized to be a contributing factor in decreased proprioceptive acuity, and therefore a contributing factor to joint injury. The findings of the present study indicate that fatigue may have an effect on proprioception following mild and maximum fatigue. Key points A repeated measures design was used to examine the effect of different levels of fatigue on active joint reposition sense (AJRS) of the knee at joint angles of 15°, 30° and 45° of flexion. A statistically significant main effect for fatigue was found, specifically between no fatigue and mild fatigue and no fatigue and maximum fatigue. A statistically significant interaction effect between AJRS and fatigue was not found. Secondary analysis of the results indicated a potential plateau effect of AJRS as fatigue continues to increase. Further investigation of the effect of increasing levels of fatigue on proprioception is warranted. PMID:24149565
Effect of different levels of localized muscle fatigue on knee position sense.
Gear, William S
2011-01-01
There is little information available regarding how proprioceptive abilities decline as the amount of exertion increases during exercise. The purpose of this study was to determine the role of different levels of fatigue on knee joint position sense. A repeated measures design was used to examine changes in active joint reposition sense (AJRS) prior to and following three levels of fatigue. Eighteen participants performed knee extension and flexion isokinetic exercise until torque output was 90%, 70%, or 50% of the peak hamstring torque for three consecutive repetitions. Active joint reposition sense at 15, 30, or 45 degrees was tested following the isokinetic exercise session. Following testing of the first independent measure, participants were given a 20 minute rest period. Testing procedures were repeated for two more exercise sessions following the other levels of fatigue. Testing of each AJRS test angle was conducted on three separate days with 48 hours between test days. Significant main effect for fatigue was indicated (p = 0.001). Pairwise comparisons indicated a significant difference between the pre-test and following 90% of peak hamstring torque (p = 0.02) and between the pre-test and following 50% of peak hamstring torque (p = 0.02). Fatigue has long been theorized to be a contributing factor in decreased proprioceptive acuity, and therefore a contributing factor to joint injury. The findings of the present study indicate that fatigue may have an effect on proprioception following mild and maximum fatigue. Key pointsA repeated measures design was used to examine the effect of different levels of fatigue on active joint reposition sense (AJRS) of the knee at joint angles of 15°, 30° and 45° of flexion.A statistically significant main effect for fatigue was found, specifically between no fatigue and mild fatigue and no fatigue and maximum fatigue.A statistically significant interaction effect between AJRS and fatigue was not found.Secondary analysis of the results indicated a potential plateau effect of AJRS as fatigue continues to increase.Further investigation of the effect of increasing levels of fatigue on proprioception is warranted.
Modeling stiffness loss in boron/aluminum below the fatigue limit
NASA Technical Reports Server (NTRS)
Johnson, W. S.
1982-01-01
Boron/aluminum can develop significant internal matrix cracking when fatigued. These matrix cracks can result in a 40 percent secant modulus loss in some laminates, even when fatigued below the fatigue limit. It is shown that the same amount of fatigue damage will develop during stress or strain-controlled tests. Stacking sequence has little influence on secant modulus loss. The secant modulus loss in unidirectional composites is small, whereas the losses are substantial in laminates containing off-axis plies. A simple analysis is presented that predicts unnotched laminate secant modulus loss due to fatigue. The analysis is based upon the elastic modulus and Poisson's ratio of the fiber and matrix, fiber volume fraction, fiber orientations, and the cyclic-hardened yield stress of the matrix material. Excellent agreement was achieved between model predictions and experimental results. With this model, designers can project the material stiffness loss for design load or strain levels and assess the feasibility of its use in stiffness-critical parts.
Predicting Fatigue Lives Of Metal-Matrix/Fiber Composites
NASA Technical Reports Server (NTRS)
Bartolotta, Paul A.
1994-01-01
Method of prediction of fatigue lives of intermetallic-matrix/fiber composite parts at high temperatures styled after method of universal slopes. It suffices to perform relatively small numbers of fatigue tests. Data from fatigue tests correlated with tensile-test data by fitting universal-slopes equation to both sets of data. Thereafter, universal-slopes equation used to predict fatigue lives from tensile properties.
Iancheva, Dessislava; Trenova, Anastasiya G; Terziyski, Kiril; Kandilarova, Sevdalina; Mantarova, Stefka
2018-04-03
Paced Auditory Serial Addition Test (PASAT) is used for assessment of information processing speed, attention, and working memory, which are the most frequently affected cognitive domains in multiple sclerosis (MS) patients, and may be significantly affected by fatigue. However, the effect of fatigue and mood on the PASAT performance in MS patients translationally validated by fMRI has not been studied yet. The aim of this study is to investigate the translational validity of the PASAT, using fMRI during a paced visual serial addition test (PVSAT) paradigm in patients with relapsing remitting MS (RRMS) and to assess the impact of fatigue and mood on test performance. Fourteen patients with RRMS in remission and 14 healthy controls, matched by sex, age, and educational status, were enrolled in the study. The subjects underwent a standard neurological examination, neuropsychological evaluation with the PASAT 3', fMRI scanning with a PVSAT paradigm, and Beck Depression Inventory. All patients were assessed by the Modified Fatigue Impact Scale. Paced Auditory Serial Addition Test score was lower in patients (41.4 ± 15.5 vs 51.6 ± 7.5, P = .035). A moderate negative correlation (P = -0.563, P = 0.036) was found between PASAT and MIFS scores. The fMRI scanning showed significant activations in several clusters that differed between patients and controls. The patient group presented wider cluster activation; Brodmann area (BA) 6-bilaterally; left BA7, 8, and 9; and right BA40, while controls presented with activations in left BA6 and BA44. Significant negative correlations between PASAT score and cortical activations in left BA23, right BA32, and left BA7 were observed in patients only. Our results show that poorer performance on the PASAT is associated with higher activation in areas connected with working memory, attention, and emotional processes during the fMRI assessment with PVSAT paradigm, which provides evidence for the translational validity of the PASAT in patients with RRMS. © 2018 John Wiley & Sons, Ltd.
Janse, Anthonie; Worm-Smeitink, Margreet; Bussel-Lagarde, José; Bleijenberg, Gijs; Nikolaus, Stephanie; Knoop, Hans
2015-08-12
Cognitive behavioural therapy (CBT) is an effective treatment for fatigue and disabilities in patients with chronic fatigue syndrome (CFS). However, treatment capacity is limited. Providing web-based CBT and tailoring the amount of contact with the therapist to the individual needs of the patient may increase the efficiency of the intervention. Web-based CBT for adolescents with CFS has proven to be effective in reducing fatigue and increasing school attendance. In the proposed study the efficacy of a web-based CBT intervention for adult patients with CFS will be explored. Two different formats of web-based CBT will be tested. In the first format named protocol driven feedback, patients report on their progress and receive feedback from a therapist according to a preset schedule. In the second format named support on demand, feedback and support of the therapist is only given when patients ask for it. The primary objective of the study is to determine the efficacy of a web-based CBT intervention on fatigue severity. A randomized clinical trial will be conducted. Two-hundred-forty adults who have been diagnosed with CFS according to the US Centers for Disease Control and Prevention (CDC) consensus criteria will be recruited and randomized to one of three conditions: web-based CBT with protocol driven feedback, web-based CBT with support on demand, or wait list. Feedback will be delivered by therapists specialized in CBT for CFS. Each of the web-based CBT interventions will be compared to a wait list condition with respect to its effect on the primary outcome measure; fatigue severity. Secondary outcome measures are level of disability, physical functioning, psychological distress, and the proportion of patients with clinical significant improvement in fatigue severity. Outcomes will be assessed at baseline and six months post randomization. The web-based CBT formats will be compared with respect to the time therapists need to deliver the intervention. As far as we know this is the first randomized controlled trial (RCT) that evaluates the efficacy of a web-based CBT intervention for adult patients with CFS. NTR4013.
Evaluation of fatigue life of CRM-reinforced SMA and its relationship to dynamic stiffness.
Mashaan, Nuha Salim; Karim, Mohamed Rehan; Abdel Aziz, Mahrez; Ibrahim, Mohd Rasdan; Katman, Herda Yati; Koting, Suhana
2014-01-01
Fatigue cracking is an essential problem of asphalt concrete that contributes to pavement damage. Although stone matrix asphalt (SMA) has significantly provided resistance to rutting failure, its resistance to fatigue failure is yet to be fully addressed. The aim of this study is to evaluate the effect of crumb rubber modifier (CRM) on stiffness and fatigue properties of SMA mixtures at optimum binder content, using four different modification levels, namely, 6%, 8%, 10%, and 12% CRM by weight of the bitumen. The testing undertaken on the asphalt mix comprises the dynamic stiffness (indirect tensile test), dynamic creep (repeated load creep), and fatigue test (indirect tensile fatigue test) at temperature of 25°C. The indirect tensile fatigue test was conducted at three different stress levels (200, 300, and 400 kPa). Experimental results indicate that CRM-reinforced SMA mixtures exhibit significantly higher fatigue life compared to the mixtures without CRM. Further, higher correlation coefficient was obtained between the fatigue life and resilient modulus as compared to permanent strain; thus resilient modulus might be a more reliable indicator in evaluating the fatigue life of asphalt mixture.
Sigrist, Hannes; Seifritz, Erich; Fikse, Lianne; Bosker, Fokko J.; Schoevers, Robert A.; Klein, Hans C.
2017-01-01
Electroconvulsive therapy (ECT) is an effective treatment for depression, but can have negative side effects including amnesia. The mechanisms of action underlying both the antidepressant and side effects of ECT are not well understood. An equivalent manipulation that is conducted in experimental animals is electroconvulsive seizure (ECS). Rodent studies have provided valuable insights into potential mechanisms underlying the antidepressant and side effects of ECT. However, relatively few studies have investigated the effects of ECS in animal models with a depression-relevant manipulation such as chronic stress. In the present study, mice were first exposed to chronic social stress (CSS) or a control procedure for 15 days followed by ECS or a sham procedure for 10 days. Behavioral effects were investigated using an auditory fear conditioning (learning) and expression (memory) test and a treadmill-running fatigue test. Thereafter, immunohistochemistry was conducted on brain material using the microglial marker Iba-1 and the cholinergic fibre marker ChAT. CSS did not increase fear learning and memory in the present experimental design; in both the control and CSS mice ECS reduced fear learning and fear memory expression. CSS induced the expected fatigue-like effect in the treadmill-running test; ECS induced increased fatigue in CSS and control mice. In CSS and control mice ECS induced inflammation in hippocampus in terms of increased expression of Iba-1 in radiatum of CA1 and CA3. CSS and ECS both reduced acetylcholine function in hippocampus as indicated by decreased expression of ChAT in several hippocampal sub-regions. Therefore, CSS increased fatigue and reduced hippocampal ChAT activity and, rather than reversing these effects, a repeated ECS regimen resulted in impaired fear learning-memory, increased fatigue, increased hippocampal Iba-1 expression, and decreased hippocampal ChAT expression. As such, the current model does not provide insights into the mechanism of ECT antidepressant function but does provide evidence for pathophysiological mechanisms that might contribute to important ECT side-effects. PMID:28910337
van Buel, Erin M; Sigrist, Hannes; Seifritz, Erich; Fikse, Lianne; Bosker, Fokko J; Schoevers, Robert A; Klein, Hans C; Pryce, Christopher R; Eisel, Ulrich Lm
2017-01-01
Electroconvulsive therapy (ECT) is an effective treatment for depression, but can have negative side effects including amnesia. The mechanisms of action underlying both the antidepressant and side effects of ECT are not well understood. An equivalent manipulation that is conducted in experimental animals is electroconvulsive seizure (ECS). Rodent studies have provided valuable insights into potential mechanisms underlying the antidepressant and side effects of ECT. However, relatively few studies have investigated the effects of ECS in animal models with a depression-relevant manipulation such as chronic stress. In the present study, mice were first exposed to chronic social stress (CSS) or a control procedure for 15 days followed by ECS or a sham procedure for 10 days. Behavioral effects were investigated using an auditory fear conditioning (learning) and expression (memory) test and a treadmill-running fatigue test. Thereafter, immunohistochemistry was conducted on brain material using the microglial marker Iba-1 and the cholinergic fibre marker ChAT. CSS did not increase fear learning and memory in the present experimental design; in both the control and CSS mice ECS reduced fear learning and fear memory expression. CSS induced the expected fatigue-like effect in the treadmill-running test; ECS induced increased fatigue in CSS and control mice. In CSS and control mice ECS induced inflammation in hippocampus in terms of increased expression of Iba-1 in radiatum of CA1 and CA3. CSS and ECS both reduced acetylcholine function in hippocampus as indicated by decreased expression of ChAT in several hippocampal sub-regions. Therefore, CSS increased fatigue and reduced hippocampal ChAT activity and, rather than reversing these effects, a repeated ECS regimen resulted in impaired fear learning-memory, increased fatigue, increased hippocampal Iba-1 expression, and decreased hippocampal ChAT expression. As such, the current model does not provide insights into the mechanism of ECT antidepressant function but does provide evidence for pathophysiological mechanisms that might contribute to important ECT side-effects.
The effect of reflexology applied on haemodialysis patients with fatigue, pain and cramps.
Ozdemir, Gülistan; Ovayolu, Nimet; Ovayolu, Ozlem
2013-06-01
The research was conducted to evaluate the effect of foot reflexology on fatigue, pain and cramps in haemodialysis patients. The sample consisted of 80 patients in total, 40 intervention and 40 control patients, receiving treatment in the haemodialysis units of two institutions. Data were collected by using a questionnaire, Piper Fatigue Scale and visual analogue scale for measuring the severity of cramp and pain. The intervention group received reflexology treatment for 1 week in three sessions following haemodialysis, each session lasting approximately 30 min. Parametric and non-parametric tests were used in data analysis. It was determined that reflexology reduced the fatigue subscale scores and total scale scores as well as pain and cramp mean scores in the intervention group. The research results revealed that the severity of fatigue, pain and cramp decreased in patients receiving reflexology. © 2013 Wiley Publishing Asia Pty Ltd.
Effects of Hot Rolling on Low-Cycle Fatigue Properties of Zn-22 wt.% Al Alloy at Room Temperature
NASA Astrophysics Data System (ADS)
Dong, X. H.; Cao, Q. D.; Ma, S. J.; Han, S. H.; Tang, W.; Zhang, X. P.
2016-09-01
The effects of the reduction ratio (RR) on the low-cycle fatigue (LCF) properties of the Zn-22 wt.% Al (Zn-22Al) alloy were investigated. Various grain sizes from 0.68 to 1.13 μm were obtained by controlled RRs. Tensile and LCF tests were carried out at room temperature. Superplasticity and cyclic softening were observed. Strength and ductility of the rolled Zn-22Al alloy increased with the RR, owing to the decrease in its grain size. The RR did not affect the cyclic softening behavior of the alloy. The fatigue life of the alloy decreased with increasing strain amplitude, while the fatigue life first decreased and then increased with increasing RR. The longest fatigue life was observed for the alloy rolled at a RR of 60%. A bilinear Coffin-Manson relationship was observed to hold true for this alloy.
High temperature tension-compression fatigue behavior of a tungsten copper composite
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Gabb, Timothy P.
1990-01-01
The high temperature fatigue of a (O)12 tungsten fiber reinforced copper matrix composite was investigated. Specimens having fiber volume percentages of 10 and 36 were fatigued under fully-reversed, strain-controlled conditions at both 260 and 560 C. The fatigue life was found to be independent of fiber volume fraction because fatigue damage preferentially occurred in the matrix. Also, the composite fatigue lives were shorter at 560 C as compared to 260 C due to changes in mode of matrix failure. On a total strain basis, the fatigue life of the composite at 560 C was the same as the life of unreinforced copper, indicating that the presence of the fibers did not degrade the fatigue resistance of the copper matrix in this composite system. Comparison of strain-controlled fatigue data to previously-generated load-controlled data revealed that the strain-controlled fatigue lives were longer because of mean strain and mean stress effects.
McCullagh, Ruth; Fitzgerald, Anthony P; Murphy, Raymond P; Cooke, Grace
2008-03-01
To determine if exercise benefits patients with multiple sclerosis. Randomized controlled trial. Participants exercised at home and also attended exercise classes held in a hospital physiotherapy gym. Thirty patients, diagnosed and independently mobile, were recruited in the Dublin area. For three months, classes were held twice-weekly and participants exercised independently once-weekly. The control group was monitored monthly and management remained unchanged. Measurements were taken at baseline, three and six months. The Modified Fatigue Impact Scale (MFIS), Multiple Sclerosis Impact Scale-29 (MSIS-29) and Functional Assessment of Multiple Sclerosis (FAMS) were used to measure fatigue and quality of life (QOL). Heart rate (HR) and the Borg's Rating of Perceived Exertion (RPE) were recorded during an incremental exercise test. The change from baseline scores between groups was compared using the Mann-Whitney U-test. Twenty-four participants completed the programme (n = 12 in each group). Based on the change in scores at three months, the exercise group had significantly greater improvements in exercise capacity (HR: -14 [-18.5, -2.5] versus 0.5 [-4, 5.5], P= 0.009), QOL (FAMS: 23 [9.5, 42.5] versus -3.5 [-16, 5], P=0.006) and fatigue (MFIS: -13 [-20, -3] versus 1 [-4, 4.5], P=0.02). At six months, the difference in change scores remained significant for FAMS (19 [14, 31] versus -4.5 [-25, 8], P=0.002) and MFIS (-8.5 [-19.5, -1] versus 0.5 [-2.5, 6.5], P=0.02) only. A three-month exercise programme improved participants' exercise capacity, QOL and fatigue, with the improvements in QOL and fatigue lasting beyond the programme.
Kumar, Anil; Vashist, Aditi; Kumar, Puneet; Kalonia, Harikesh; Mishra, Jitendriya
2012-01-01
Chronic fatigue stress (CFS) is a common complaint among general population. Persistent and debilitating fatigue severely impairs daily functioning and is usually accompanied by combination of several physical and psychiatric problems. It is now well established fact that oxidative stress and neuroinflammation are involved in the pathophysiology of chronic fatigue and related disorders. Targeting both COX (cyclooxygenase) and 5-LOX (lipoxygenase) pathways have been proposed to be involved in neuroprotective effect. In the present study, mice were put on the running wheel apparatus for 6 min test session daily for 21 days, what produced fatigue like condition. The locomotor activity and anxiety like behavior were measured on 0, 8(th), 15(th) and 22(nd) day. The brains were isolated on 22(nd) day immediately after the behavioral assessments for the estimation of oxidative stress parameters and mitochondrial enzyme complexes activity. Pre-treatment with licofelone (2.5, 5 and 10 mg/kg, po) and minocycline (50 and 100 mg/kg, po) for 21 days, significantly attenuated fatigue like behavior as compared to the control (rotating wheel activity test session, RWATS) group. Further, licofelone (5 and 10 mg/kg, po) and minocycline (50 and 100 mg/kg, po) drug treatments for 21 days significantly attenuated behavioral alterations, oxidative damage and restored mitochondrial enzyme complex activities (I, II, III and IV) as compared to control, whereas combination of licofelone (5 mg/kg) with minocycline (50 mg/kg) significantly potentiated their protective effect which was significant as compared to their effect per se. The present study highlights the therapeutic potential of licofelone, minocycline and their combination against CFS in mice.
Fatigue crack identification method based on strain amplitude changing
NASA Astrophysics Data System (ADS)
Guo, Tiancai; Gao, Jun; Wang, Yonghong; Xu, Youliang
2017-09-01
Aiming at the difficulties in identifying the location and time of crack initiation in the castings of helicopter transmission system during fatigue tests, by introducing the classification diagnostic criteria of similar failure mode to find out the similarity of fatigue crack initiation among castings, an engineering method and quantitative criterion for detecting fatigue cracks based on strain amplitude changing is proposed. This method is applied on the fatigue test of a gearbox housing, whose results indicates: during the fatigue test, the system alarms when SC strain meter reaches the quantitative criterion. The afterwards check shows that a fatigue crack less than 5mm is found at the corresponding location of SC strain meter. The test result proves that the method can provide accurate test data for strength life analysis.
Determination of the Proper Rest Time for a Cyclic Mental Task Using ACT-R Architecture.
Atashfeshan, Nooshin; Razavi, Hamideh
2017-03-01
Objective Analysis of the effect of mental fatigue on a cognitive task and determination of the right start time for rest breaks in work environments. Background Mental fatigue has been recognized as one of the most important factors influencing individual performance. Subjective and physiological measures are popular methods for analyzing fatigue, but they are restricted to physical experiments. Computational cognitive models are useful for predicting operator performance and can be used for analyzing fatigue in the design phase, particularly in industrial operations and inspections where cognitive tasks are frequent and the effects of mental fatigue are crucial. Method A cyclic mental task is modeled by the ACT-R architecture, and the effect of mental fatigue on response time and error rate is studied. The task includes visual inspections in a production line or control workstation where an operator has to check products' conformity to specifications. Initially, simulated and experimental results are compared using correlation coefficients and paired t test statistics. After validation of the model, the effects are studied by human and simulated results, which are obtained by running 50-minute tests. Results It is revealed that during the last 20 minutes of the tests, the response time increased by 20%, and during the last 12.5 minutes, the error rate increased by 7% on average. Conclusion The proper start time for the rest period can be identified by setting a limit on the error rate or response time. Application The proposed model can be applied early in production planning to decrease the negative effects of mental fatigue by predicting the operator performance. It can also be used for determining the rest breaks in the design phase without an operator in the loop.
Motor unit behaviour and contractile changes during fatigue in the human first dorsal interosseus
Carpentier, Alain; Duchateau, Jacques; Hainaut, Karl
2001-01-01
In 67 single motor units, the mechanical properties, the recruitment and derecruitment thresholds, and the discharge rates were recorded concurrently in the first dorsal interosseus (FDI) of human subjects during intermittent fatiguing contractions. The task consisted of isometric ramp-and-hold contractions performed at 50% of the maximal voluntary contraction (MVC). The purpose of this study was to examine the influence of fatigue on the behaviour of motor units with a wide range of activation thresholds. For low-threshold (< 25% MVC) motor units, the mean twitch force increased with fatigue and the recruitment threshold either did not change or increased. In contrast, the twitch force and the activation threshold decreased for the high-threshold (> 25% MVC) units. The observation that in low-threshold motor units a quick stretch of the muscle at the end of the test reset the unit force and recruitment threshold to the prefatigue value suggests a significant role for fatigue-related changes in muscle stiffness but not twitch potentiation or motor unit synchronization. Although the central drive intensified during the fatigue test, as indicated by an increase in surface electromyogram (EMG), the discharge rate of the motor units during the hold phase of each contraction decreased progressively over the course of the task for motor units that were recruited at the beginning of the test, especially the low-threshold units. In contrast, the discharge rates of newly activated units first increased and then decreased. Such divergent behaviour of low- and high-threshold motor units could not be individually controlled by the central drive to the motoneurone pool. Rather, the different behaviours must be the consequence of variable contributions from motoneurone adaptation and afferent feedback from the muscle during the fatiguing contraction. PMID:11483719
Fatigue properties of superelastic Ti-Ni filaments and braided cables for bone fixation.
Baril, Y; Brailovski, V
2010-02-01
This work is focused on the fatigue properties of the braided hollow tubular cables for bone fixation made of superelastic Ti-Ni filaments. To evaluate the fatigue life of the cable and the impact of braiding on fatigue life, a comparative study was conducted on both the braided cable and the single filament. The results of strain-controlled fatigue testing under variable mean and alternating strain conditions demonstrated that: (a) even though alternating strain is the most influent parameter, mean strain also has a significant impact on the fatigue life of both the filament and the braid; an improvement in the braided cable's fatigue life is observed under mean strains corresponding to the middle of the superelastic loop plateau; and (b) run-out (10(5) cycles) is reached at 1% of alternating strain for the filament, and at 0.3% for the braided cable. It was proved that the negative impact of braiding on fatigue life is caused: (a) by friction-induced damage of the braided filaments during cable manufacturing and (b) by locally occurring bending in the vicinity of the filaments' crossing, combined with the interfilament fretting during repetitive stretching of the braided cable.
Effects of microstructural inclusions on fatigue life of polyether ether ketone (PEEK).
Simsiriwong, Jutima; Shrestha, Rakish; Shamsaei, Nima; Lugo, Marcos; Moser, Robert D
2015-11-01
In this study, the effects of microstructural inclusions on fatigue life of polyether ether ketone (PEEK) was investigated. Due to the versatility of its material properties, the semi-crystralline PEEK polymer has been increasingly adopted in a wide range of applications particularly as a biomaterial for orthopedic, trauma, and spinal implants. To obtain the cyclic behavior of PEEK, uniaxial fully-reversed strain-controlled fatigue tests were conducted at ambient temperature and at 0.02 mm/mm to 0.04 mm/mm strain amplitudes. The microstructure of PEEK was obtained using the optical and the scanning electron microscope (SEM) to determine the microstructural inclusion properties in PEEK specimen such as inclusion size, type, and nearest neighbor distance. SEM analysis was also conducted on the fracture surface of fatigue specimens to observe microstructural inclusions that served as the crack incubation sites. Based on the experimental strain-life results and the observed microstructure of fatigue specimens, a microstructure-sensitive fatigue model was used to predict the fatigue life of PEEK that includes both crack incubation and small crack growth regimes. Results show that the employed model is applicable to capture microstructural effects on fatigue behavior of PEEK. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dailey, Dana L; Rakel, Barbara A; Vance, Carol GT; Liebano, Richard E; Anand, Amrit S; Bush, Heather M; Lee, Kyoung S; Lee, Jennifer E; Sluka, Kathleen A
2014-01-01
Because TENS works by reducing central excitability and activating central inhibition pathways, we tested the hypothesis that TENS would reduce pain and fatigue and improve function and hyperalgesia in people with fibromyalgia who have enhanced central excitability and reduced inhibition. The current study used a double-blinded randomized, placebo controlled cross-over design to test effects of a single treatment of TENS in people with fibromyalgia. Three treatments were assessed in random order: active TENS, placebo TENS, no TENS. The following measures were assessed before and after each TENS treatment: pain and fatigue at rest and movement, pressure pain thresholds (PPTs), 6 minute walk test (6MWT), range of motion (ROM), five time sit to stand test (FTSTS), and single leg stance (SLS). Conditioned pain modulation (CPM) was completed at end of testing. There was a significant decrease in pain and fatigue with movement for active TENS compared to placebo and no TENS. PPTs increased at site of TENS (spine) and outside site of TENS (leg) when compared to placebo TENS or no TENS. During Active TENS CPM was significantly stronger compared to placebo TENS and no TENS. No changes in functional tasks were observed with TENS. Thus, the current study suggests TENS has short-term efficacy in relieving symptoms of fibromyalgia while the stimulator is active. Future clinical trials should examine the effects of repeated daily delivery of TENS, similar to how TENS is used clinically, on pain, fatigue, function and quality of life in individuals with fibromyalgia. PMID:23900134
Miladinia, Mojtaba; Baraz, Shahram; Shariati, Abdolali; Malehi, Amal Saki
Patients with acute leukemia usually experience pain, fatigue, and sleep disorders, which affect their quality of life. Massage therapy, as a nondrug approach, can be useful in controlling such problems. However, very few studies have been conducted on the effects of massage therapy on the complications of leukemia. The aim of this study was to examine the effects of slow-stroke back massage (SSBM) on the symptom cluster in acute leukemia adult patients undergoing chemotherapy. In this randomized controlled trial, 60 patients with acute leukemia were allocated randomly to either the intervention or control group. The intervention group received SSBM 3 times a week (every other day for 10 minutes) for 4 weeks. The pain, fatigue, and sleep disorder intensities were measured using the numeric rating scale. The sleep quality was measured using the Pittsburgh Sleep Quality Index. Statistical tests of χ, t test, and the repeated-measure analysis of variance were used for data analysis. Results showed that the SSBM intervention significantly reduced the progressive sleep disorder, pain, fatigue, and improved sleep quality over time. Slow-stroke back massage, as a simple, noninvasive, and cost-effective approach, along with routine nursing care, can be used to improve the symptom cluster of pain, fatigue, and sleep disorders in leukemia patients. Oncology nurses can increase their knowledge regarding this symptom cluster and work to diminish the cluster components by using SSBM in adult leukemia patients.
Westbrook, Travis D; Maddocks, Kami; Andersen, Barbara L
2016-07-01
Chronic lymphocytic leukaemia (CLL) is the most prevalent adult leukaemia and is incurable. The course and treatment of CLL is unique and characterised by repeated cycles of treatment, stable disease and relapse. Utilising a Self-Regulatory Model framework, we examined the relationship between patients' illness perceptions and cancer-specific stress, depressive symptoms and fatigue. Our aim was to test illness perceptions as predictors of these outcomes when variance due to disease and treatment variables was controlled. Data were collected on 147 patients with relapsed/refractory CLL as they entered a phase II clinical trial of an investigational medication at a university affiliated, National Cancer Institute designated comprehensive cancer center. Cancer-specific stress, depressive symptoms and fatigue interference. . Hierarchical multiple regression was used. Consequences and emotional representation were related to all outcomes (ps < .01). Illness concern was related to cancer-specific stress (p < .01), and identity was related to fatigue interference (p < .01). All relationships were observed while controlling for number of previous CLL therapies received. Illness perceptions are related to cancer-specific stress, depressive symptoms and fatigue interference in relapsed/refractory CLL. Interventions targeted at restructuring maladaptive illness perceptions may have clinical benefit in this population.
Koyama, Taku; Sato, Toru; Yoshinari, Masao
2012-01-01
This study investigated the influence of surface roughness and cyclic loading on fatigue resistance in Y-TZP subjected to hot isostatic pressing (HIP). Fifty Y-TZP cylinders 3.0 mm in diameter were divided into Group A (polished by centerless method; TZP-CP) or Group B (blasted and acid-etched: TZP-SB150E). Twenty five cp-titanium cylinders (Ti-SB150E) were used as a control. Static and cyclic tests were carried out according to ISO 14801. The cyclic fatigue test was performed in distilled water at 37°C. Surface morphology and roughness as well as crystal phase on the surfaces were also evaluated. Fracture force under the static test was 1,765N (TZP-CP), 1,220N (TZP-SB150E), and 850 N (yield force, Ti-SB150E). Fracture values under the cyclic test decreased to approximately 70% of those under the static tests. These results indicate that HIPed Y-TZP with a 3.0-mm diameter has sufficient durability for application to dental implants.
The Cyclic Stress-Strain Behavior of a Single Crystal Nickel-Base Superalloy. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.
1988-01-01
The cyclic stress-strain response and similar deformation structures of the single crystal nickel based superalloy was described under a specific set of conditions. The isothermal low cycle fatigue response and deformation structures were described at a typical intermediate temperature and at high temperature. Specimens oriented near the (001) and (111) crystallographic orientations were tested at 1050 C, where more moderate orientation effects were expected. This enabled the description of the deformation structures at each of the 2 temperatures and their relationship to the observed cyclic stress-strain behavior. The initial yield strength of all specimens tested at 650 C was controlled by the shearing of the gamma prime precipitates by dislocation pairs. Low cycle fatigue tests at 650 C had cyclic hardening, which was associated with dislocation interactions in the gamma matrix. The initial yield strength of specimens tested at 1050 C was associated with dislocation bypassing of the gamma prime precipitates. Low cycle fatigue tests at 1050 C had cyclic softening, associated with extensive dislocation recovery at the gamma-gamma prime interfaces along with some gamma prime precipitate coarsening.
Influence of Lumbar Muscle Fatigue on Trunk Adaptations during Sudden External Perturbations
Abboud, Jacques; Nougarou, François; Lardon, Arnaud; Dugas, Claude; Descarreaux, Martin
2016-01-01
Introduction: When the spine is subjected to perturbations, neuromuscular responses such as reflex muscle contractions contribute to the overall balance control and spinal stabilization mechanisms. These responses are influenced by muscle fatigue, which has been shown to trigger changes in muscle recruitment patterns. Neuromuscular adaptations, e.g., attenuation of reflex activation and/or postural oscillations following repeated unexpected external perturbations, have also been described. However, the characterization of these adaptations still remains unclear. Using high-density electromyography (EMG) may help understand how the nervous system chooses to deal with an unknown perturbation in different physiological and/or mechanical perturbation environments. Aim: To characterize trunk neuromuscular adaptations following repeated sudden external perturbations after a back muscle fatigue task using high-density EMG. Methods: Twenty-five healthy participants experienced a series of 15 sudden external perturbations before and after back muscle fatigue. Erector spinae muscle activity was recorded using high-density EMG. Trunk kinematics during perturbation trials were collected using a 3-D motion analysis system. A two-way repeated measure ANOVA was conducted to assess: (1) the adaptation effect across trials; (2) the fatigue effect; and (3) the interaction effect (fatigue × adaptation) for the baseline activity, the reflex latency, the reflex peak and trunk kinematic variables (flexion angle, velocity and time to peak velocity). Muscle activity spatial distribution before and following the fatigue task was also compared using t-tests for dependent samples. Results: An attenuation of muscle reflex peak was observed across perturbation trials before the fatigue task, but not after. The spatial distribution of muscle activity was significantly higher before the fatigue task compared to post-fatigue trials. Baseline activity showed a trend to higher values after muscle fatigue, as well as reduction through perturbation trials. Main effects of fatigue and adaptation were found for time to peak velocity. No adaptation nor fatigue effect were identified for reflex latency, flexion angle or trunk velocity. Conclusion: The results show that muscle fatigue leads to reduced spatial distribution of back muscle activity and suggest a limited ability to use across-trial redundancy to adapt EMG reflex peak and optimize spinal stabilization using retroactive control. PMID:27895569
Prediction of Frequency for Simulation of Asphalt Mix Fatigue Tests Using MARS and ANN
Fakhri, Mansour
2014-01-01
Fatigue life of asphalt mixes in laboratory tests is commonly determined by applying a sinusoidal or haversine waveform with specific frequency. The pavement structure and loading conditions affect the shape and the frequency of tensile response pulses at the bottom of asphalt layer. This paper introduces two methods for predicting the loading frequency in laboratory asphalt fatigue tests for better simulation of field conditions. Five thousand (5000) four-layered pavement sections were analyzed and stress and strain response pulses in both longitudinal and transverse directions was determined. After fitting the haversine function to the response pulses by the concept of equal-energy pulse, the effective length of the response pulses were determined. Two methods including Multivariate Adaptive Regression Splines (MARS) and Artificial Neural Network (ANN) methods were then employed to predict the effective length (i.e., frequency) of tensile stress and strain pulses in longitudinal and transverse directions based on haversine waveform. It is indicated that, under controlled stress and strain modes, both methods (MARS and ANN) are capable of predicting the frequency of loading in HMA fatigue tests with very good accuracy. The accuracy of ANN method is, however, more than MARS method. It is furthermore shown that the results of the present study can be generalized to sinusoidal waveform by a simple equation. PMID:24688400
Prediction of frequency for simulation of asphalt mix fatigue tests using MARS and ANN.
Ghanizadeh, Ali Reza; Fakhri, Mansour
2014-01-01
Fatigue life of asphalt mixes in laboratory tests is commonly determined by applying a sinusoidal or haversine waveform with specific frequency. The pavement structure and loading conditions affect the shape and the frequency of tensile response pulses at the bottom of asphalt layer. This paper introduces two methods for predicting the loading frequency in laboratory asphalt fatigue tests for better simulation of field conditions. Five thousand (5000) four-layered pavement sections were analyzed and stress and strain response pulses in both longitudinal and transverse directions was determined. After fitting the haversine function to the response pulses by the concept of equal-energy pulse, the effective length of the response pulses were determined. Two methods including Multivariate Adaptive Regression Splines (MARS) and Artificial Neural Network (ANN) methods were then employed to predict the effective length (i.e., frequency) of tensile stress and strain pulses in longitudinal and transverse directions based on haversine waveform. It is indicated that, under controlled stress and strain modes, both methods (MARS and ANN) are capable of predicting the frequency of loading in HMA fatigue tests with very good accuracy. The accuracy of ANN method is, however, more than MARS method. It is furthermore shown that the results of the present study can be generalized to sinusoidal waveform by a simple equation.
Recovery of upper limb muscle function in chronic fatigue syndrome with and without fibromyalgia.
Ickmans, Kelly; Meeus, Mira; De Kooning, Margot; Lambrecht, Luc; Nijs, Jo
2014-02-01
Chronic fatigue syndrome (CFS) patients frequently complain of muscle fatigue and abnormally slow recovery, especially of the upper limb muscles during and after activities of daily living. Furthermore, disease heterogeneity has not yet been studied in relation to recovery of muscle function in CFS. Here, we examine recovery of upper limb muscle function from a fatiguing exercise in CFS patients with (CFS+FM) and without (CFS-only) comorbid fibromyalgia and compare their results with a matched inactive control group. In this case-control study, 18 CFS-only patients, 30 CFS+FM patients and 30 healthy inactive controls performed a fatiguing upper limb exercise test with subsequent recovery measures. There was no significant difference among the three groups for maximal handgrip strength of the non-dominant hand. A significant worse recovery of upper limb muscle function was found in the CFS+FM, but not in de CFS-only group compared with the controls (P < 0·05). This study reveals, for the first time, delayed recovery of upper limb muscle function in CFS+FM, but not in CFS-only patients. The results underline that CFS is a heterogeneous disorder suggesting that reducing the heterogeneity of the disorder in future research is important to make progress towards a better understanding and uncovering of mechanisms regarding the nature of divers impairments in these patients. © 2013 Stichting European Society for Clinical Investigation Journal Foundation. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Yu, W.; Esaklul, K.; Gerberich, W. W.
1984-05-01
It is shown that closure mechanisms alone cannot fully explain increasing fatigue thresholds with decreasing test temperature for a sequence of Fe-Si binary alloys and an HSLA steel. Implications are that fatigue crack propagation near threshold is a thermally activated process. The effective threshold stress intensity, which was obtained by subtracting the closure portion from the fatigue threshold, was examined. This effective stress intensity was found to correlate very well to the thermal component of the flow stress. A detailed fractographic study of the fatigue surface was performed. Water vapor in the room air was found to promote the formation of oxide and intergranular crack growth. At lower temperature, a brittle-type cyclic cleavage fatigue surface was observed but the ductile process persisted even at 123 K. Arrest marks were found on all three modes of fatigue crack growth. The regular spacings between these lines and dislocation modeling suggested that fatigue crack growth was controlled by the subcell structure near threshold. A model based on the slip-off of dislocations was examined. From this, it is shown that the effective fatigue threshold may be related to the square root of (one plus the strain rate sensitivity).
Location, location & size: defects close to surfaces dominate fatigue crack initiation
NASA Astrophysics Data System (ADS)
Serrano-Munoz, Itziar; Buffiere, Jean-Yves; Mokso, Rajmund; Verdu, Catherine; Nadot, Yves
2017-03-01
Metallic cast components inevitably contain defects such as shrinkage cavities which are inherent to the solidification process. Those defects are known to significantly alter the fatigue life of components. Yet very little is known, quantitatively, on the dangerosity of internal casting defects compared to surface ones. In this study, fatigue specimens containing controlled internal defects (shrinkage pores) are used to foster internal cracking. In situ fatigue tests monitored by X ray synchrotron tomography revealed that the internal nucleation and propagation of cracks was systematically overran by surface cracking initiated at castings defects up to ten times smaller than the internal ones. These findings indicate that the presence of internal defects in cast components can be tolerated to a larger extent than is allowed by nowadays standards
Location, location &size: defects close to surfaces dominate fatigue crack initiation.
Serrano-Munoz, Itziar; Buffiere, Jean-Yves; Mokso, Rajmund; Verdu, Catherine; Nadot, Yves
2017-03-27
Metallic cast components inevitably contain defects such as shrinkage cavities which are inherent to the solidification process. Those defects are known to significantly alter the fatigue life of components. Yet very little is known, quantitatively, on the dangerosity of internal casting defects compared to surface ones. In this study, fatigue specimens containing controlled internal defects (shrinkage pores) are used to foster internal cracking. In situ fatigue tests monitored by X ray synchrotron tomography revealed that the internal nucleation and propagation of cracks was systematically overran by surface cracking initiated at castings defects up to ten times smaller than the internal ones. These findings indicate that the presence of internal defects in cast components can be tolerated to a larger extent than is allowed by nowadays standards.
Location, location & size: defects close to surfaces dominate fatigue crack initiation
Serrano-Munoz, Itziar; Buffiere, Jean-Yves; Mokso, Rajmund; Verdu, Catherine; Nadot, Yves
2017-01-01
Metallic cast components inevitably contain defects such as shrinkage cavities which are inherent to the solidification process. Those defects are known to significantly alter the fatigue life of components. Yet very little is known, quantitatively, on the dangerosity of internal casting defects compared to surface ones. In this study, fatigue specimens containing controlled internal defects (shrinkage pores) are used to foster internal cracking. In situ fatigue tests monitored by X ray synchrotron tomography revealed that the internal nucleation and propagation of cracks was systematically overran by surface cracking initiated at castings defects up to ten times smaller than the internal ones. These findings indicate that the presence of internal defects in cast components can be tolerated to a larger extent than is allowed by nowadays standards PMID:28345599
Hosoi, Atsushi; Kishi, Tomoya; Ju, Yang
2013-01-01
A technique to heal a fatigue crack in austenitic stainless steel SUS316 by applying a controlled, high-density pulsed current was developed. A surface-activated pre-coating (SAPC), which eliminates the oxide layer and coats a Ni film on the crack surface, was used to improve the adhesion between crack surfaces. Cracks were observed by scanning electron microscopy before and after the application of high-density electropulsing. To evaluate the healing effect of the SAPC during crack propagation, fatigue tests were conducted under a constant stress intensity factor. The fatigue crack treated with the SAPC was found to be effectively healed as a result of electropulsing, and also showed a slower rate of crack propagation. PMID:28788327
Möller, Marika C; Nordin, Love Engström; Bartfai, Aniko; Julin, Per; Li, Tie-Qiang
2017-01-01
Fatigue is the most frequently reported persistent symptom following a mild traumatic brain injury (mTBI), but the explanations for the persisting fatigue symptoms in mTBI remain controversial. In this study, we investigated the change of cerebral blood flow during the performance of a psychomotor vigilance task (PVT) by using pseudo-continuous arterial spin labeling (PCASL) MRI technique to better understand the relationship between fatigability and brain activity in mTBI. Ten patients (mean age: 37.5 ± 11.2 years) with persistent complaints of fatigue after mTBI and 10 healthy controls (mean age 36.9 ± 11.0 years) were studied. Both groups completed a 20-min long PVT inside a clinical MRI scanner during simultaneous measurements of reaction time and regional cerebral blood flow (rCBF) with PCASL technique. Cognitive fatigability and neural activity during PVT were analyzed by dividing the performance and rCBF data into quintiles in addition to the assessment of self-rated fatigue before and after the PVT. The patients showed significant fatigability during the PVT while the controls had a stable performance. The variability in performance was also significantly higher among the patients, indicating monitoring difficulty. A three-way ANOVA, modeling of the rCBF data demonstrated that there was a significant interaction effect between the subject group and performance time during PVT in a mainly frontal/thalamic network, indicating that the pattern of rCBF change for the mTBI patients differed significantly from that of healthy controls. In the mTBI patients, fatigability at the end of the PVT was related to increased rCBF in the right middle frontal gyrus, while self-rated fatigue was related to increased rCBF in left medial frontal and anterior cingulate gyri and decreases of rCBF in a frontal/thalamic network during this period. This study demonstrates that PCASL is a useful technique to investigate neural correlates of fatigability and fatigue in mTBI patients. Patients suffering from fatigue after mTBI used different brain networks compared to healthy controls during a vigilance task and in mTBI, there was a distinction between rCBF changes related to fatigability vs. perceived fatigue. Whether networks for fatigability and self-rated fatigue are different, needs to be investigated in future studies.
Elevated temperature axial and torsional fatigue behavior of Haynes 188
NASA Astrophysics Data System (ADS)
Bonacuse, Peter J.; Kalluri, Sreeramesh
1992-06-01
The results of high-temperature axial and torsional low-cycle fatigue experiments performed on Haynes 188, a wrought cobalt-base superalloy, are reported. Fatigue tests were performed at 760 C in air on thin-walled tubular specimens at various ranges under strain control. Data are also presented for coefficient of thermal expansion, elastic modulus, and shear modulus at various temperatures from room to 1000 C, and monotonic and cyclic stress-strain curves in tension and in shear at 760 C. The data set is used to evaluate several multiaxial fatigue life models (most were originally developed for room temperature multiaxial life prediction) including von Mises equivalent strain range (ASME boiler and pressure vessel code), Manson-Halford, Modified Multiaxiality Factor (proposed here), Modified Smith-Watson-Topper, and Fatemi-Socie-Kurath. At von Mises equivalent strain ranges (the torsional strain range divided by the square root of 3, taking the Poisson's ratio to be 0.5), torsionally strained specimens lasted, on average, factors of 2 to 3 times longer than axially strained specimens. The Modified Multiaxiality Factor approach shows promise as a useful method of estimating torsional fatigue life from axial fatigue data at high temperatures. Several difficulties arose with the specimen geometry and extensometry used in these experiments. Cracking at extensometer probe indentations was a problem at smaller strain ranges. Also, as the largest axial and torsional strain range fatigue tests neared completion, a small amount of specimen buckling was observed.
NASA Astrophysics Data System (ADS)
Yang, Zhuofei; Kang, Jidong; Wilkinson, David S.
2015-08-01
AM60 high pressure die castings have been used in automobile applications to reduce the weight of vehicles. However, the pore defects that are inherent in die casting may negatively affect mechanical properties, especially the fatigue properties. Here we have studied damage ( e.g., pore defects, fatigue cracks) during strained-controlled fatigue using 3-dimensional X-ray computed tomography (XCT). The fatigue test was interrupted every 2000 cycles and the specimen was removed to be scanned using a desktop micro-CT system. XCT reveals pore defects, cracks, and fracture surfaces. The results show that pores can be accurately measured and modeled in 3D. Defect bands are found to be made of pores under 50 µm (based on volume-equivalent sphere diameter). Larger pores are randomly distributed in the region between the defect bands. Observation of fatigue cracks by XCT is performed in three ways such that the 3D model gives the best illustration of crack-porosity interaction while the other two methods, with the cracks being viewed on transverse or longitudinal cross sections, have better detectability on crack initiation and crack tip observation. XCT is also of value in failure analysis on fracture surfaces. By assessing XCT data during fatigue testing and observing fracture surfaces on a 3D model, a better understanding on the crack initiation, crack-porosity interaction, and the morphology of fracture surface is achieved.
Low-Cycle Fatigue Behavior of 10CrNi3MoV High Strength Steel and Its Undermatched Welds
Liu, Xuesong; Berto, Filippo
2018-01-01
The use of high strength steel allows the design of lighter, more slender and simpler structures due to high strength and favorable ductility. Nevertheless, the increase of yield strength does not guarantee the corresponding improvement of fatigue resistance, which becomes a major concern for engineering structure design, especially for the welded joints. The paper presents a comparison of the low cycle fatigue behaviors between 10CrNi3MoV high strength steel and its undermatched weldments. Uniaxial tension tests, Push-pull, strain-controlled fatigue tests were conducted on base metal and weldments in the strain range of 0.2–1.2%. The monotonic and cyclic stress-strain curves, stress-life, strain-life and energy-life in terms of these materials were analyzed for fatigue assessment of materials discrepancy. The stress-life results of base metal and undermatched weld metal exhibit cyclic softening behaviors. Furthermore, the shapes of 10CrNi3MoV steel hysteresis loops show a satisfactory Masing-type behavior, while the weld metal shows a non-Masing type behavior. Strain, plastic and total strain energy density amplitudes against the number of reversals to failure results demonstrate that the undermatched weld metal presents a higher resistance to fatigue crack initiation than 10CrNi3MoV high strength steel. Finally, fatigue fracture surfaces of specimens were compared by scanning electron microscopy to identify the differences of crack initiation and the propagation between them. PMID:29695140
Elevated temperature axial and torsional fatigue behavior of Haynes 188
NASA Technical Reports Server (NTRS)
Bonacuse, Peter J.; Kalluri, Sreeramesh
1992-01-01
The results of high-temperature axial and torsional low-cycle fatigue experiments performed on Haynes 188, a wrought cobalt-base superalloy, are reported. Fatigue tests were performed at 760 C in air on thin-walled tubular specimens at various ranges under strain control. Data are also presented for coefficient of thermal expansion, elastic modulus, and shear modulus at various temperatures from room to 1000 C, and monotonic and cyclic stress-strain curves in tension and in shear at 760 C. The data set is used to evaluate several multiaxial fatigue life models (most were originally developed for room temperature multiaxial life prediction) including von Mises equivalent strain range (ASME boiler and pressure vessel code), Manson-Halford, Modified Multiaxiality Factor (proposed here), Modified Smith-Watson-Topper, and Fatemi-Socie-Kurath. At von Mises equivalent strain ranges (the torsional strain range divided by the square root of 3, taking the Poisson's ratio to be 0.5), torsionally strained specimens lasted, on average, factors of 2 to 3 times longer than axially strained specimens. The Modified Multiaxiality Factor approach shows promise as a useful method of estimating torsional fatigue life from axial fatigue data at high temperatures. Several difficulties arose with the specimen geometry and extensometry used in these experiments. Cracking at extensometer probe indentations was a problem at smaller strain ranges. Also, as the largest axial and torsional strain range fatigue tests neared completion, a small amount of specimen buckling was observed.
Low-Cycle Fatigue Behavior of 10CrNi3MoV High Strength Steel and Its Undermatched Welds.
Song, Wei; Liu, Xuesong; Berto, Filippo; Razavi, S M J
2018-04-24
The use of high strength steel allows the design of lighter, more slender and simpler structures due to high strength and favorable ductility. Nevertheless, the increase of yield strength does not guarantee the corresponding improvement of fatigue resistance, which becomes a major concern for engineering structure design, especially for the welded joints. The paper presents a comparison of the low cycle fatigue behaviors between 10CrNi3MoV high strength steel and its undermatched weldments. Uniaxial tension tests, Push-pull, strain-controlled fatigue tests were conducted on base metal and weldments in the strain range of 0.2⁻1.2%. The monotonic and cyclic stress-strain curves, stress-life, strain-life and energy-life in terms of these materials were analyzed for fatigue assessment of materials discrepancy. The stress-life results of base metal and undermatched weld metal exhibit cyclic softening behaviors. Furthermore, the shapes of 10CrNi3MoV steel hysteresis loops show a satisfactory Masing-type behavior, while the weld metal shows a non-Masing type behavior. Strain, plastic and total strain energy density amplitudes against the number of reversals to failure results demonstrate that the undermatched weld metal presents a higher resistance to fatigue crack initiation than 10CrNi3MoV high strength steel. Finally, fatigue fracture surfaces of specimens were compared by scanning electron microscopy to identify the differences of crack initiation and the propagation between them.
Effects of Acute Fatigue of the Hip Flexor Muscles on Hamstring Muscle Extensibility.
Muyor, José M; Arrabal-Campos, Francisco M
2016-12-01
The purpose of the present study was to evaluate the influence of acute fatigue of the hip flexor muscles on scores attained in tests frequently used in literature to measure hamstring muscle extensibility, namely the passive straight leg raise (PSLR), active straight leg raise (ASLR), passive knee extension (PKE), active knee extension (AKE), sit-and-reach (SR) and toe-touch (TT) tests. A total of seventy-five healthy and recreationally active adults voluntarily participated in this study. To reach fatigue, the participants actively lifted their legs alternately as many times as possible. In the passive tests, the results were 7.10 ± 5.21° and 5.68 ± 4.54° higher (p < 0.01) for PSLR and PKE tests, respectively, after acute fatigue. However, in the ASLR test, the results were lower post-fatigue than pre-fatigue (mean difference = -5.30° ± 9.51°; p < 0.01). The AKE, SR and TT tests did not show significant differences between pre- and post-fatigue (p > 0.05). Moderate (r = 0.40) to high (r = 0.97) correlation coefficients were found, which were statistically significant among all the measured flexibility tests both pre- and post-fatigue. In conclusion, the active implication of the hip flexor muscles until reaching fatigue had acute influences on the results of the PSLR, PKE and ASLR tests, but not on the results of the AKE, SR and TT tests. It is recommended to use the AKE test to assess hamstring muscle extensibility in situations where athletes show fatigue in their hip flexor muscles.
Kargarfard, Mehdi; Etemadifar, Masoud; Baker, Peter; Mehrabi, Maryam; Hayatbakhsh, Reza
2012-10-01
To examine the effectiveness of aquatic exercise training on fatigue and health-related quality of life (HRQOL) in women with multiple sclerosis (MS). Randomized controlled trial, 4-week and 8-week follow-up. Referral center of a multiple sclerosis society. Women (N=32) diagnosed with relapsing-remitting MS (mean age ± SD, 32.6±8.0y) were recruited into this study. After undergoing baseline testing by a neurologist, participants were randomly assigned to either an intervention (aquatic exercise) or a control group. The intervention consisted of 8 weeks supervised aquatic exercise in a swimming pool (3 times a week, each session lasting 60min). At baseline, 4 weeks, and 8 weeks, fatigue and HRQOL were assessed by a blind assessor using the Modified Fatigue Impact Scale and the Multiple Sclerosis Quality of Life-54 questionnaire, respectively. A mixed-model approach to repeated-measures analysis of variance was used to detect within- and between-subject effects. Findings are based on 21 patients (10 from the exercise group and 11 from the control group) who had data available on outcomes. There was no significant difference between the 2 groups at the baseline. Patients in the aquatic exercise group showed significant improvements in fatigue and subscores of HRQOL after 4 and 8 weeks compared with the control group. Results obtained from the intention-to-treat analysis were consistent with those of per-protocol analysis. The findings suggest that aquatic exercise training can effectively improve fatigue and HRQOL of patients with MS and should be considered in the management of this relatively common public health problem. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Zimmerman, Richard S.; Adams, Donald F.
1989-01-01
Static laminate and tension-tension fatigue tests of IM7/8551-7 composite materials was performed. The Edge Delamination Test (EDT) was utilized to evaluate the temperature and preloading history effect on the critical strain energy release rate. Static and fatigue testing was performed at room temperature and 180 F (82 C). Three preloading schemes were used to precondition fatigue test specimens prior to performing the normal tension-tension fatigue EDT testing. Computer software was written to perform all fatigue testing while monitoring the dynamic modulus to detect the onset of delamination and record the test information for later retrieval and reduction.
Steady-state temperature determination on the base of hysteresis loop energy for CuZn37 brass
NASA Astrophysics Data System (ADS)
Lipski, Adam; Skibicki, Dariusz; Pejkowski, Łukasz
2017-03-01
This paper presents the verification of the relationship between the temperature and the hysteresis loop energy for the CuZn37 brass under multiaxial fatigue loading. Fatigue tests were performed on the hollow specimens subjected to fully reversed tension-compression, torsion, proportional loading, 90° out-of-phase non-proportional loading and two another non-proportional loadings with frequency differences. All test were strain-controlled. Calculations of a plastic strain energy were based on midlife strain hysteresis loops data. The calculated specimen temperatures were compared with temperatures observed by thermographic camera.
NASA Astrophysics Data System (ADS)
Vecchio, Kenneth S.; Fitzpatrick, Michael D.; Klarstrom, Dwaine
1995-03-01
Strain-controlled low-cycle fatigue tests have been conducted in air at elevated temperature to determine the influence of subsolvus thermomechanical processing on the low-cycle fatigue (LCF) behavior of HAYNES 230 alloy. A series of tests at various strain ranges was conducted on material experimentally processed at 1121 °C, which is below the M23C6 carbide solvus temperature, and on material fully solution annealed at 1232 °C. A comparative strain-life analysis was performed on the LCF results, and the cyclic hardening/softening characteristics were examined. At 760 °C and 871 °C, the fatigue life of the experimental 230/1121 material was improved relative to the standard 230/1232 material up to a factor of 3. The fatigue life advantage of the experimental material was related primarily to a lower plastic (inelastic) strain amplitude response for a given imposed total strain range. It appears the increase in monotonic flow stress exhibited by the finer grain size experimental material has been translated into an increase in cyclic flow stress at the 760 °C and 871 °C test temperatures. Both materials exhibited entirely transgranular fatigue crack initiation and propagation modes at these temperatures. The LCF performance of the experimental material in tests performed at 982 °C was improved relative to the standard material up to a factor as high as 2. The life advantage of the 230/1121 material occurred despite having a larger plastic strain amplitude than the standard 230/1232 material for a given total strain range. Though not fully understood at present, it is suspected that this behavior is related to the deleterious influence of grain boundaries in the fatigue crack initiations of the standard processed material relative to the experimental material, and ultimately to differences in carbide morphology as a result of thermomechanical processing.
Carter, Stephen J; Hunter, Gary R; McAuley, Edward; Courneya, Kerry S; Anton, Philip M; Rogers, Laura Q
2016-10-01
Research showing a link between exercise-induced changes in aerobic fitness and reduced fatigue after a cancer diagnosis has been inconsistent. We evaluated associations of fatigue and rate-pressure product (RPP), a reliable index of myocardial oxygen demand, at rest and during submaximal walking following a physical activity intervention among post-primary treatment breast cancer survivors (BCS). Secondary analyses of 152 BCS in a randomized controlled trial testing a physical activity intervention (INT) versus usual care (UC) were performed. The INT group completed counseling/group discussions along with supervised exercise sessions tapered to unsupervised exercise. Evaluations were made at baseline and immediately post-intervention (M3) on measures of physical activity (accelerometry), graded walk test, and average fatigue over the previous 7 days. RPP was calculated by dividing the product of heart rate and systolic blood pressure by 100. Resting and submaximal RPPs were significantly improved in both groups at M3; however, the magnitude of change (∆) was greater in the INT group from stage 1 (∆RPP1; INT -13 ± 17 vs. UC -7 ± 18; p = 0.03) through stage 4 (∆RPP4; INT -21 ± 26 vs. UC -9 ± 24; p < 0.01) of the walk test. The INT group reported significantly reduced fatigue (INT -0.7 ± 2.0 vs. UC +0.1 ± 2.0; p = 0.02) which was positively associated with ∆RPP during stages 2-4 of the walk test but not ∆aerobic fitness. Lower RPP during submaximal walking was significantly associated with reduced fatigue in BCS. Exercise/physical activity training programs that lower the physiological strain during submaximal walking may produce the largest improvements in reported fatigue.
Mediators of the effects on fatigue of pragmatic rehabilitation for chronic fatigue syndrome.
Wearden, Alison J; Emsley, Richard
2013-10-01
To examine potential mediators of the effect of pragmatic rehabilitation on improvements in fatigue following a randomized controlled trial for patients with chronic fatigue syndrome (CFS/ME) in primary care (IRCTN 74156610). Patients fulfilled the Oxford criteria for CFS. Ninety-five patients were randomized to pragmatic rehabilitation and 100 to general practitioner (GP) treatment as usual. The outcome was the Chalder fatigue scale score (0123 scoring) at end of treatment (20 weeks) and 1-year follow up (70 weeks). First, the effect of treatment on potential mediators was assessed. Then fatigue was regressed on significant mediators, treatment allocation, and baseline measures of fatigue and significant mediators. Reduction in limiting activities at 20 weeks mediated the positive effect of pragmatic rehabilitation on fatigue at 70 weeks (mediated effect size = -2.64, SE = 0.81, p = .001, proportion of effect mediated = 82.0%). Reduction in catastrophizing at 20 weeks mediated the positive effect of pragmatic rehabilitation on fatigue at 70 weeks (mediated effect size = -1.39, SE = 0.61, p = .023, proportion of effect mediated = 43.2%). Reductions in 70-week measures of fear avoidance, embarrassment avoidance, limiting activities, and all-or-nothing behavior all mediated improvement in fatigue at 70 weeks, although the causal direction of these cross-sectional effects cannot be determined. There were no between-group differences on measures of exercise capacity (a timed step test). Improvements in fatigue following pragmatic rehabilitation are related to changes in behavioral responses to and beliefs about fatigue.
Fatigue behavior of ULTIMETRTM alloy: Experiment and theoretical modeling
NASA Astrophysics Data System (ADS)
Jiang, Liang
ULTIMETRTM alloy is a commercial Co-26Cr-9Ni (weight percent) superalloy, which possesses excellent resistance to both wear and corrosion. In order to extend the structural applications of this alloy and improve the fundamental understanding of the fatigue damage mechanisms, stress- and strain-controlled fatigue tests were performed at various temperatures and in different environments. The stress- and strain-life data were developed for the structural design and engineering applications of this material. Fractographic studies characterized the crack-initiation and propagation behavior of the alloy. Microstructure evolution during fatigue was revealed by x-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Specifically, it was found that the metastable face-centered-cubic structure of this alloy in the as-received condition could be transformed into a hexagonal-close-packed structure either under the action of plastic deformation at room temperature, or due to the aging and cyclic deformation at intermediate temperatures. This interesting observation constructed a sound basis for the alloy development. The dominant mechanisms, which control the fatigue behavior of ULTIMET alloy, were characterized. High-speed, high-resolution infrared (IR) thermography, as a non-contact, full-field, and nondestructive technique, was used to characterize the damage during fatigue. The temperature variations during each fatigue cycle, which were due to the thermal-elastic-plastic effect, were observed and related to stress-strain analyses. The temperature evolution during fatigue manifested the cumulative fatigue damage process. A constitutive model was developed to predict thermal and mechanical responses of ULTIMET alloy subjected to cyclic deformation. The predicted cyclic stress-strain responses and temperature variations were found to be in good agreement with the experimental results. In addition, a fatigue life prediction model was developed based on the strain-energy consideration, and the measured temperature could be utilized as an index for fatigue-life prediction.
A Chronic Fatigue Syndrome (CFS) severity score based on case designation criteria.
Baraniuk, James N; Adewuyi, Oluwatoyin; Merck, Samantha Jean; Ali, Mushtaq; Ravindran, Murugan K; Timbol, Christian R; Rayhan, Rakib; Zheng, Yin; Le, Uyenphuong; Esteitie, Rania; Petrie, Kristina N
2013-01-01
Chronic Fatigue Syndrome case designation criteria are scored as physicians' subjective, nominal interpretations of patient fatigue, pain (headaches, myalgia, arthralgia, sore throat and lymph nodes), cognitive dysfunction, sleep and exertional exhaustion. Subjects self-reported symptoms using an anchored ordinal scale of 0 (no symptom), 1 (trivial complaints), 2 (mild), 3 (moderate), and 4 (severe). Fatigue of 3 or 4 distinguished "Fatigued" from "Not Fatigued" subjects. The sum of the 8(Sum8) ancillary criteria was tested as a proxy for fatigue. All subjects had history and physical examinations to exclude medical fatigue, and ensure categorization as healthy or CFS subjects. Fatigued subjects were divided into CFS with ≥4 symptoms or Chronic Idiopathic Fatigue (CIF) with ≤3 symptoms. ROC of Sum8 for CFS and Not Fatigued subjects generated a threshold of 14 (specificity=0.934; sensitivity=0.928). CFS (n=256) and CIF (n=55) criteria were refined to include Sum8≥14 and ≤13, respectively. Not Fatigued subjects had highly skewed Sum8 responses. Healthy Controls (HC; n=269) were defined by fatigue≤2 and Sum8≤13. Those with Sum8≥14 were defined as CFS-Like With Insufficient Fatigue Syndrome (CFSLWIFS; n=20). Sum8 and Fatigue were highly correlated (R(2)=0.977; Cronbach's alpha=0.924) indicating an intimate relationship between symptom constructs. Cluster analysis suggested 4 clades each in CFS and HC. Translational utility was inferred from the clustering of proteomics from cerebrospinal fluid. Plotting Fatigue severity versus Sum8 produced an internally consistent classifying system. This is a necessary step for translating symptom profiles into fatigue phenotypes and their pathophysiological mechanisms.
Kwekkeboom, Kristine L.; Abbott-Anderson, Kristen; Wanta, Britt
2009-01-01
Purpose To evaluate the feasibility of a patient-controlled cognitive-behavioral intervention for pain, fatigue, and sleep disturbance during treatment for advanced cancer, and to assess initial efficacy of the intervention in controlling symptoms. Design One-group pretest-posttest design. Setting Outpatient oncology clinics at a Comprehensive Cancer Center in the Midwestern United States. Sample 30 adults with advanced (recurrent or metastatic) colorectal, lung, prostate, or GYN cancer receiving chemotherapy or radiotherapy. Methods Participants completed baseline measures (demographics, symptom inventory) and received education and training to use an MP3 player loaded with 12 cognitive-behavioral strategies (e.g., relaxation exercises, guided imagery, nature sound recordings). Participants used the strategies as needed for symptom management over the following 2-weeks, keeping a log of symptom ratings with each use. Following the two-week intervention, participants completed a second symptom inventory and an evaluation of the intervention. Main Research Variables Feasibility, patient-controlled cognitive-behavioral intervention, pain, fatigue, sleep disturbance. Findings 73% of the 43 eligible patients agreed to participate (N=30) and of these, 90% (n=27) completed the study. The majority of participants reported that they enjoyed the intervention, had learned useful skills, and perceived improvement in their symptoms. Symptom scores at 2-weeks did not differ significantly from baseline, however significant reductions in pain, fatigue, and sleep disturbance severity were found in ratings made immediately before and after use of a cognitive-behavioral strategy. Conclusions The patient-controlled cognitive-behavioral intervention appears feasible for further study and could reduce day-to-day severity of co-occurring pain, fatigue, and sleep disturbance. Implications for Nursing A randomized controlled trial is necessary to test efficacy of the intervention for co-occurring pain, fatigue, and sleep disturbance. In the mean time, based on previous efficacy studies, cognitive-behavioral strategies can be recommended for certain individual symptoms. PMID:20439200
Travier, Noémie; Velthuis, Miranda J; Steins Bisschop, Charlotte N; van den Buijs, Bram; Monninkhof, Evelyn M; Backx, Frank; Los, Maartje; Erdkamp, Frans; Bloemendal, Haiko J; Rodenhuis, Carla; de Roos, Marnix A J; Verhaar, Marlies; ten Bokkel Huinink, Daan; van der Wall, Elsken; Peeters, Petra H M; May, Anne M
2015-06-08
Exercise started shortly after breast cancer diagnosis might prevent or diminish fatigue complaints. The Physical Activity during Cancer Treatment (PACT) study was designed to primarily examine the effects of an 18-week exercise intervention, offered in the daily clinical practice setting and starting within 6 weeks after diagnosis, on preventing an increase in fatigue. This multi-centre controlled trial randomly assigned 204 breast cancer patients to usual care (n = 102) or supervised aerobic and resistance exercise (n = 102). By design, all patients received chemotherapy between baseline and 18 weeks. Fatigue (i.e., primary outcome at 18 weeks), quality of life, anxiety, depression, and physical fitness were measured at 18 and 36 weeks. Intention-to-treat mixed linear model analyses showed that physical fatigue increased significantly less during cancer treatment in the intervention group compared to control (mean between-group differences at 18 weeks: -1.3; 95 % CI -2.5 to -0.1; effect size -0.30). Results for general fatigue were comparable but did not reach statistical significance (-1.0, 95%CI -2.1; 0.1; effect size -0.23). At 18 weeks, submaximal cardiorespiratory fitness and several muscle strength tests (leg extension and flexion) were significantly higher in the intervention group compared to control, whereas peak oxygen uptake did not differ between groups. At 36 weeks these differences were no longer statistically significant. Quality of life outcomes favoured the exercise group but were not significantly different between groups. A supervised 18-week exercise programme offered early in routine care during adjuvant breast cancer treatment showed positive effects on physical fatigue, submaximal cardiorespiratory fitness, and muscle strength. Exercise early during treatment of breast cancer can be recommended. At 36 weeks, these effects were no longer statistically significant. This might have been caused by the control participants' high physical activity levels during follow-up. Current Controlled Trials ISRCTN43801571, Dutch Trial Register NTR2138. Trial registered on December 9th, 2009.
Creep fatigue life prediction for engine hot section materials (isotropic)
NASA Technical Reports Server (NTRS)
Nelson, R. S.; Levan, G. W.; Harvey, P. R.
1992-01-01
This Final Report covers the activities completed under the optional program of the NASA HOST Contract, NAS3-23288. The initial effort of the optional program was report-in NASA CR189221, which consisted of high temperature strain controlled fatigue tests to study the effects of thermomechanical fatigue, multiaxial loading, reactive environments, and imposed stresses. The baseline alloy used in the tests included B1900+Hf (with or without coating) and wrought INCO 718. Tests conducted on B1900+Hf included environmental tests using various atmospheres (75 psig oxygen, purified argon, or block exposures) and specimen tests of wrought INCO 718 included tensile, creep, stress rupture, TMF, multiaxial, and mean stress tests. Results of these testings were used to calibrate a CDA model for INCO 718 alloy and to develop modifications or corrections to the CDA model to handle additional failure mechanisms. The Socie parameter was found to provide the best correlation for INCO multiaxial loading. Microstructural evaluations consisting of optical, Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM) techniques, and surface replication techniques to determine crack initiation lives provided data which were used to develop life prediction models.
Anti-Fatigue Effects of the Unique Polysaccharide Marker of Dendrobium officinale on BALB/c Mice.
Wei, Wei; Li, Zhi-Peng; Zhu, Tong; Fung, Hau-Yee; Wong, Tin-Long; Wen, Xin; Ma, Dik-Lung; Leung, Chung-Hang; Han, Quan-Bin
2017-01-18
Dendrobium officinale extract shows potent anti-fatigue effects; however, the active substance responsible for these effects remains undetermined. A glucomannan with a huge molecular size of 730 kDa, called DOP, was identified as the unique authentication marker of this expensive herb. DOP exhibited immunomodulating effects on macrophages and lymphocytes in our previous study. Clinical reports also showed that people with fatigue syndrome have a disturbed immune system. Because DOP is the unique and dominant component of D. officinale , we hypothesize that DOP may also have anti-fatigue activity. The present study aims to evaluate the anti-fatigue activity of DOP on BALB/c mice, with Rhodiola rosea extract as a positive control. DOP and Rhodiola rosea extract were orally administered at doses of 50 mg/kg and 100 mg/kg, respectively, for four weeks, and the anti-fatigue activity of DOP on BALB/c mice was evaluated using the weight-loaded swimming test. The contents of lactic dehydrogenase (LDH), creatine phosphokinase (CK), triglyceride (TG), blood urea nitrogen (BUN), superoxide dismutase (SOD), malondialdehyde (MDA), lactic acid (LD), and glutathione peroxidase (GSH-Px) in serum, glycogen of liver and gastrocnemius muscle were also determined. Their effects on variability of T cells and B cells were determined by using tetrazolium compound (MTS) method. The weight-loaded swimming exercise caused fatigue syndrome, mainly including the decreases of serum SOD/GSH-Px and gastrocnemius glycogen, as well as the increases of LDH, BUN, MDA, CK, TG, and LD in serum. All of these indicators of fatigue were inhibited to a certain extent by both DOP and Rhodiola rosea extract; however, the effects of DOP were much stronger than those of Rhodiola rosea extract. Compared to the positive control, mice dosed with DOP showed increases in endurance, body weight, and food intake. Furthermore, DOP-feeding mice significantly increased the cell variability of T lymphocytes and B lymphocytes, compared with that of mice in control group. This study indicates that the unique and dominant polysaccharide DOP of D. officinale has stronger anti-fatigue activity than Rhodiola rosea extract. As such, DOP has promising potential for pharmaceutical development into health products to reduce fatigue.
Giboin, Louis-Solal; Thumm, Patrick; Bertschinger, Raphael; Gruber, Markus
2016-01-01
Despite the potential of repetitive transcranial magnetic stimulation (rTMS) to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesized that after an intermittent theta burst (iTBS) treatment, performance during the Wingate Anaerobic Test (WAnT) will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment. Ten subjects participated in two randomized experiments consisting of a WAnT 5 min after either an iTBS or a control treatment. We determined voluntary activation (VA) of the right knee extensors with TMS (VATMS) and with peripheral nerve stimulation (VAPNS) of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a two way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioral changes related to fatigue (mean power and fatigue index) were observed. These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task. PMID:27486391
Giboin, Louis-Solal; Thumm, Patrick; Bertschinger, Raphael; Gruber, Markus
2016-01-01
Despite the potential of repetitive transcranial magnetic stimulation (rTMS) to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesized that after an intermittent theta burst (iTBS) treatment, performance during the Wingate Anaerobic Test (WAnT) will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment. Ten subjects participated in two randomized experiments consisting of a WAnT 5 min after either an iTBS or a control treatment. We determined voluntary activation (VA) of the right knee extensors with TMS (VATMS) and with peripheral nerve stimulation (VAPNS) of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a two way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioral changes related to fatigue (mean power and fatigue index) were observed. These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task.
Effects of local and widespread muscle fatigue on movement timing.
Cowley, Jeffrey C; Dingwell, Jonathan B; Gates, Deanna H
2014-12-01
Repetitive movements can cause muscle fatigue, leading to motor reorganization, performance deficits, and/or possible injury. The effects of fatigue may depend on the type of fatigue task employed, however. The purpose of this study was to determine how local fatigue of a specific muscle group versus widespread fatigue of various muscle groups affected the control of movement timing. Twenty healthy subjects performed an upper extremity low-load work task similar to sawing for 5 continuous minutes both before and after completing a protocol that either fatigued all the muscles used in the task (widespread fatigue) or a protocol that selectively fatigued the primary muscles used to execute the pushing stroke of the sawing task (localized fatigue). Subjects were instructed to time their movements with a metronome. Timing error, movement distance, and speed were calculated for each movement. Data were then analyzed using a goal-equivalent manifold approach to quantify changes in goal-relevant and non-goal-relevant variability. We applied detrended fluctuation analysis to each time series to quantify changes in fluctuation dynamics that reflected changes in the control strategies used. After localized fatigue, subjects made shorter, slower movements and exerted greater control over non-goal-relevant variability. After widespread fatigue, subjects exerted less control over non-goal-relevant variability and did not change movement patterns. Thus, localized and widespread muscle fatigue affected movement differently. Local fatigue may reduce the available motor solutions and therefore cause greater movement reorganization than widespread muscle fatigue. Subjects altered their control strategies but continued to achieve the timing goal after both fatigue tasks.
Evaluation of Fatigue Life of CRM-Reinforced SMA and Its Relationship to Dynamic Stiffness
Mashaan, Nuha Salim; Karim, Mohamed Rehan; Abdel Aziz, Mahrez; Ibrahim, Mohd Rasdan; Katman, Herda Yati
2014-01-01
Fatigue cracking is an essential problem of asphalt concrete that contributes to pavement damage. Although stone matrix asphalt (SMA) has significantly provided resistance to rutting failure, its resistance to fatigue failure is yet to be fully addressed. The aim of this study is to evaluate the effect of crumb rubber modifier (CRM) on stiffness and fatigue properties of SMA mixtures at optimum binder content, using four different modification levels, namely, 6%, 8%, 10%, and 12% CRM by weight of the bitumen. The testing undertaken on the asphalt mix comprises the dynamic stiffness (indirect tensile test), dynamic creep (repeated load creep), and fatigue test (indirect tensile fatigue test) at temperature of 25°C. The indirect tensile fatigue test was conducted at three different stress levels (200, 300, and 400 kPa). Experimental results indicate that CRM-reinforced SMA mixtures exhibit significantly higher fatigue life compared to the mixtures without CRM. Further, higher correlation coefficient was obtained between the fatigue life and resilient modulus as compared to permanent strain; thus resilient modulus might be a more reliable indicator in evaluating the fatigue life of asphalt mixture. PMID:25050406
Divided attention deficits in patients with chronic fatigue syndrome.
Ross, S; Fantie, B; Straus, S F; Grafman, J
2001-01-01
Chronic fatigue syndrome (CFS) patients and controls were compared on a variety of mood state, personality, and neuropsychological measures, including memory, word finding, and attentional tasks that required participants to focus, sustain, or divide their attention, or to perform a combination of these functions. CFS patients demonstrated a selective deficit on 3 measures of divided attention. Their performance on the other neuropsychological tests of intelligence, fluency, and memory was no different than that of normal controls despite their reports of generally diminished cognitive capacity. There was an inverse relation between CFS patient fatigue severity and performance on 1 of the divided attention measures. Given these findings, it is probable that CFS patients will report more cognitive difficulties in real-life situations that cause them to divide their effort or rapidly reallocate cognitive resources between 2 response channels (vision and audition).
Elbow flexor fatigue modulates central excitability of the knee extensors.
Aboodarda, Saied Jalal; Copithorne, David B; Power, Kevin E; Drinkwater, Eric; Behm, David G
2015-09-01
The present study investigated the effects of exercise-induced elbow flexor fatigue on voluntary force output, electromyographic (EMG) activity and motoneurone excitability of the nonexercised knee extensor muscles. Eleven participants attended 3 testing sessions: (i) control, (ii) unilateral fatiguing elbow flexion and (iii) bilateral fatiguing elbow flexion (BiFlex). The nonfatigued knee extensor muscles were assessed with thoracic motor evoked potentials (TMEPs), maximal compound muscle action potential (Mmax), knee extensor maximal voluntary contractions (MVCs), and normalized EMG activity before and at 30 s, 3 min, and 5 min postexercise. BiFlex showed significantly lower (Δ = -18%, p = 0.03) vastus lateralis (VL) normalized EMG activity compared with the control session whereas knee extension MVC force did not show any statistical difference between the 3 conditions (p = 0.12). The TMEP·Mmax(-1) ratio measured at the VL showed a significantly higher value (Δ = +46%, p = 0.003) following BiFlex compared with the control condition at 30 s postexercise. The results suggest that the lower VL normalized EMG following BiFlex might have been due to a reduction in supraspinal motor output because spinal motoneuronal responses demonstrated substantially higher value (30 s postexercise) and peripheral excitability (compound muscle action potential) showed no change following BiFelex than control condition.
Yazdizadeh, Mohammad; Skini, Masoumeh; Hoseini Goosheh, Seyyed Mohsen; Jafarzadeh, Mansour; Shamohammadi, Milad; Rakhshan, Vahid
2017-01-01
Introduction: Cyclic fatigue is the common reason for breakage of rotary instruments. This study was conducted to evaluate the effect of cryogenic treatment (CT) in improving the resistance to cyclic fatigue of endodontic rotary instruments. Methods and Materials: In this in vitro study, 20 RaCe and 20 Mtwo files were randomly divided into two groups of negative control and CT. CT files were stored in liquid nitrogen at -196°C for 24 h, and then were gradually warmed to the room temperature. All files were used (at torques and speeds recommended by their manufacturers) in a simulated canal with a 45° curvature until breakage. The time to fail (TF) was recorded and used to calculate the number of cycle to fail (NCF). Groups were compared using independent-samples t-test. Results: Mean NCFs were 1248.2±68.1, 1281.6±78.6, 4126.0±179.2, and 4175.4±190.1 cycles, for the Mtwo-control, Mtwo-CT, RaCe-control, and RaCe-CT, respectively. The difference between the controls and their respective CT groups were not significant (P>0.3). The difference between the systems was significant. Conclusion: Deep CT did not improve resistance to cyclic fatigue of the evaluated rotary files. PMID:28512489
Fractography of induction-hardened steel fractured in fatigue and overload
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santos, C.G.; Laird, C.
1997-07-01
The fracture surfaces of induction-hardened steel specimens obtained from an auto axle were characterized, macroscopically and microscopically, after being fractured in fatigue and monotonic overload. Specimens were tested in cyclic three-point bending under load control, and the S-N curve was established for specimens that had been notched by spark machining to facilitate fractography. Scanning electron microscopy of the fractured surfaces obtained for lives spanning the range 17,000 to 418,000 cycles revealed diverse fracture morphologies, including intergranular fracture and transgranular fatigue fracture. The results are being offered to assist in the analysis of complex field failures in strongly hardened steel.
Combustion Device Failures During Space Shuttle Main Engine Development
NASA Technical Reports Server (NTRS)
Goetz, Otto K.; Monk, Jan C.
2005-01-01
Major Causes: Limited Initial Materials Properties. Limited Structural Models - especially fatigue. Limited Thermal Models. Limited Aerodynamic Models. Human Errors. Limited Component Test. High Pressure. Complicated Control.
NASA Technical Reports Server (NTRS)
Russell, H W; Jackson, L R; Grover, H J; Beaver, W W
1944-01-01
Report contains detailed results of a number of fatigue tests on spot-welded joints in aluminum alloys. The tests described include: (1) fatigue tests on spot-welded lap joints in sheets of unequal thickness of alclad 24s-t. These tests indicate that the fatigue strength of a spot-welded joint in sheets of two different gages is slightly higher than that of a similar joint in two sheets of the thinner gage but definitely lower than that of a similar joint in two sheets of the thicker gage. (2) Fatigue tests on spot-welded alclad 75s-t spot-welded lap-joint specimens of alclad 75s-t were not any stronger in fatigue than similar specimens of alclad 24s-t. (3) Fatigue tests on lap-joint specimens spot -welded after various surface preparations--these included ac welding wire-brushed surfaces, dc welding wire-brushed surfaces, and dc welding chemically cleaned surfaces. While the ac welds were strongest statically, the dc welds on wire-brushed surfaces were strongest in fatigue. Specimens prepared in this way were very nearly as strong as the best riveted specimens tested for comparison. (4) Fatigue tests on specimens spot-welded with varying voltage so as to include a wide range of static spot-weld strengths. The fatigue strengths were in the same order as the static strengths but showed less range. (author)
Maroti, Daniel; Westerberg, Annika Fryxell; Saury, Jean-Michel; Bileviciute-Ljungar, Indre
2015-08-18
Patients with myalgic encephalomyelitis/chronic fatigue syndrome experience cognitive difficulties. The aim of this study was to evaluate the effect of computerized training on working memory in this syndrome. Non-randomized (quasi-experimental) study with no-treatment control group and non-equivalent dependent variable design in a myalgic encephalomyelitis/chronic fatigue syndrome-cohort. Patients with myalgic encephalomyelitis/chronic fatigue syndrome who participated in a 6-month outpatient rehabilitation programme were included in the study. Eleven patients who showed signs of working memory deficit were recruited for additional memory training and 12 patients with no working memory deficit served as controls. Cognitive training with computerized working memory tasks of increasing difficulty was performed 30-45 min/day, 5 days/week over a 5-week period. Short-term and working memory tests (Digit Span - forward, backward, total) were used as primary outcome measures. Nine of the 11 patients were able to complete the training. Cognitive training increased working memory (p = 0.003) and general attention (p = 0.004) to the mean level. Short-term memory was also improved, but the difference was not statistically significant (p = 0.052) vs prior training. The control group did not show any significant improvement in primary outcome measures. Cognitive training may be a new treatment for patients with myalgic encephalomyelitis/chronic fatigue syndrome.
Simulation of Fatigue Crack Initiation at Corrosion Pits With EDM Notches
NASA Technical Reports Server (NTRS)
Smith, Stephen W.; Newman, John A.; Piascik, Robert S.
2003-01-01
Uniaxial fatigue tests were conducted to compare the fatigue life of laboratory produced corrosion pits, similar to those observed in the shuttle main landing gear wheel bolt-hole, and an electro-discharged-machined (EDM) flaw. EDM Jaws are used to simulate corrosion pits during shuttle wheel (dynamometer) testing. The aluminum alloy, (AA 7050) laboratory fatigue tests were conducted to simulate the local stress level contained in the wheel bolt-hole. Under this high local stress condition, the EDM notch produced a fatigue life similar to test specimens containing corrosion pits of similar size. Based on the laboratory fatigue test results, the EDM Jaw (semi-circular disc shaped) produces a local stress state similar to corrosion pits and can be used to simulate a corrosion pit during the shuttle wheel dynamometer tests.
Comparing the effects of reflexology and relaxation on fatigue in women with multiple sclerosis.
Nazari, Fatemeh; Shahreza, Mozhgan Soheili; Shaygannejad, Vahid; Valiani, Mahboubeh
2015-01-01
Fatigue is the most common and highly disabling symptom of multiple sclerosis (MS) that has negative effects on employment, the process of socialization, compliance with the disease, and other factors effective on activities of daily living. The usage of complementary and alternative medicine methods in MS patients is higher than in the general population. However, there is no scientific evidence to support their effectiveness. Therefore, this study aimed to compare the effects of reflexology and relaxation on fatigue in women with MS. This study is a single-blinded randomized clinical trial that was done on 75 patients with MS who referred to the MS Clinic of Ayatollah Kashani Hospital (Isfahan, Iran). After simple non-random sampling, participants were randomly assigned by minimization method to three groups: Reflexology, relaxation, and control groups (25 patients in each group). In the experimental groups, the interventions foot reflexology and relaxation (Jacobson and Benson) were performed for 4 weeks, twice a week for 40 min in each session, and the control group received care and routine medical treatment as directed by a physician. Data were collected through a questionnaire and the fatigue severity scale before, immediately after, and 2 months after interventions from all three groups. Data analysis was performed by SPSS version 18 using descriptive and inferential statistical methods. Findings obtained from analysis of variance (ANOVA) showed that there was no significant difference in the mean fatigue severity scores in the pre-interventions between the three groups (P > 0.05), but there was significant difference immediately after and 2 months after interventions between the three groups (P < 0.05). Findings obtained from repeated measures (ANOVA) showed that there was significant difference in the mean fatigue severity scores during different times between the three groups (P < 0.05), while this difference was not significant in the control group (P > 0.05). Furthermore, least significant difference post-hoc test revealed that the mean scores of fatigue severity immediately after intervention was lower in the reflexology group than in the other two groups and were lower in the relaxation group than in the control group; 2 months after interventions, the mean scores of fatigue severity were lower in the reflexology group than in the other two groups, but there was no significant difference between the two groups of relaxation and control (P > 0.05). It seems that both interventions were effective in reducing fatigue, but the effects of reflexology on reducing fatigue were more than those of relaxation. Hence, as these two methods are effective and affordable techniques, they can be recommended.
External anal sphincter fatigue is not improved by N-acetylcysteine in an animal model.
Healy, C F; McMorrow, C; O'Herlihy, C; O'Connell, P R; Jones, J F X
2008-06-01
Oxidative stress is associated with skeletal muscle fatigue. This study tests the hypotheses that N-acetylcysteine (NAC) reduces fatigue and accelerates recovery of the rat external anal sphincter (EAS). Fifteen female Wistar rats were killed humanely. The EAS was mounted as a ring preparation and electrically stimulated with 50 Hz trains of 200 ms in duration every 4 s for three and a half minutes. Three groups were analysed: a control group (n = 5), a group pretreated with NAC (10(-4) mol L(-1); n = 5) and a group pretreated with NAC (10(-3) mol L(-1); n = 5). A novel fatigue index was formulated and was compared to a conventional method of expressing fatigue. There was no significant difference at concentrations of NAC (10(-4) mol L(-1); P > 0.05). At high concentrations of NAC (10(-3) mol L(-1)) there was a significant depression in peak twitch amplitude before fatigue (P = 0.04). N-acetylcysteine in both concentrations used, did not alter fatigue or recovery of the rat EAS. There was a significant positive correlation between the two methods of expressing fatigue but the conventional method produced a higher fatigue index (22.4% on average). N-acetylcysteine does not ameliorate fatigue or accelerate recovery of the EAS and may not be a useful medical therapy for faecal incontinence.
Evaluation of the ergogenic potential of noni juice.
Ma, De-lu; West, Brett J; Su, Chen X; Gao, Jian-hua; Liu, Tin-zhong; Liu, Yu-Wen
2007-11-01
Morinda citrifolia (noni) fruit juice is an increasingly popular health food with many reported benefits, such as antioxidant and immunomodulatory properties. Traditionally, noni fruit was used by Polynesians to combat fatigue. Also, clinical studies have revealed that noni juice consumption improves quality of life scores related to physical functioning and energy levels. To further evaluate the ergogenic (antifatigue and endurance promoting) potential of noni juice, aged mice were pretreated orally with increasing doses (10, 20 and 40 mL/kg body weight) of Tahitian Noni Juice (TNJ) and then compared with young and aged controls in the forced swim test and rotarod test. The average times of all TNJ dose groups were significantly longer than the aged controls in both the swim test (36% to 45%) and the rotarod test (59% to 128%), and were similar to those of the young controls. This demonstrates not only an improvement in endurance but also in balance and flexibility. These results confirm the reported use of noni juice to combat fatigue, improve endurance and increase overall physical performance. Copyright (c) 2007 John Wiley & Sons, Ltd.
Dual-axis resonance testing of wind turbine blades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, Scott; Musial, Walter; White, Darris
An apparatus (100) for fatigue testing test articles (104) including wind turbine blades. The apparatus (100) includes a test stand (110) that rigidly supports an end (106) of the test article (104). An actuator assembly (120) is attached to the test article (104) and is adapted for substantially concurrently imparting first and second forcing functions in first and second directions on the test article (104), with the first and second directions being perpendicular to a longitudinal axis. A controller (130) transmits first and second sets of displacement signals (160, 164) to the actuator assembly (120) at two resonant frequencies ofmore » the test system (104). The displacement signals (160, 164) initiate the actuator assembly (120) to impart the forcing loads to concurrently oscillate the test article (104) in the first and second directions. With turbine blades, the blades (104) are resonant tested concurrently for fatigue in the flapwise and edgewise directions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yongming; Oskay, Caglar
This report outlines the research activities that were carried out for the integrated experimental and simulation investigation of creep-fatigue damage mechanism and life prediction of Nickel-based alloy, Inconel 617 at high temperatures (950° and 850°). First, a novel experimental design using a hybrid control technique is proposed. The newly developed experimental technique can generate different combinations of creep and fatigue damage by changing the experimental design parameters. Next, detailed imaging analysis and statistical data analysis are performed to quantify the failure mechanisms of the creep fatigue of alloy 617 at high temperatures. It is observed that the creep damage ismore » directly associated with the internal voids at the grain boundaries and the fatigue damage is directly related to the surface cracking. It is also observed that the classical time fraction approach does not has a good correlation with the experimental observed damage features. An effective time fraction parameter is seen to have an excellent correlation with the material microstructural damage. Thus, a new empirical damage interaction diagram is proposed based on the experimental observations. Following this, a macro level viscoplastic model coupled with damage is developed to simulate the stress/strain response under creep fatigue loadings. A damage rate function based on the hysteresis energy and creep energy is proposed to capture the softening behavior of the material and a good correlation with life prediction and material hysteresis behavior is observed. The simulation work is extended to include the microstructural heterogeneity. A crystal plasticity finite element model considering isothermal and large deformation conditions at the microstructural scale has been developed for fatigue, creep-fatigue as well as creep deformation and rupture at high temperature. The model considers collective dislocation glide and climb of the grains and progressive damage accumulation of the grain boundaries. The glide model incorporates a slip resistance evolution model that characterizes the solute-drag creep effects and can capture well the stress-strain and stress time response of fatigue and creep-fatigue tests at various strain ranges and hold times. In order to accurately capture the creep strains that accumulate particularly at relatively low stress levels, a dislocation climb model has been incorporated into the crystal plasticity modeling framework. The dislocation climb model parameters are calibrated and verified through experimental creep tests performed at 950°. In addition, a cohesive zone model has been fully implemented in the context of the crystal plasticity finite element model to capture the intergranular creep damage. The parameters of the cohesive zone model have been calibrated using available experimental data. The numerical simulations illustrate the capability of the proposed model in capturing damage initiation and growth under creep loads as compared to the experimental observations. The microscale analysis sheds light on the crack initiation sites and propagation patterns within the microstructure. The model is also utilized to investigate the hybrid-controlled creep-fatigue tests and has been found to capture reasonably well the stress-strain response with different hold times and hold stress magnitudes.« less
Thermomechanical and isothermal fatigue behavior of a (90)sub 8 titanium matrix composite
NASA Technical Reports Server (NTRS)
Castelli, Michael G.
1993-01-01
An experimental investigation was conducted to analyze the fatigue damage mechanisms operative in a 35 fiber volume percent (90 deg) titanium matrix composite (TMC) under 427 C isothermal and thermomechanical loading conditions. The thermomechanical fatigue (TMF) tests were performed with a temperature cycle from 200 to 427 C under closely controlled conditions to define both the deformation and fatigue life behavior. Degradation of the TMC's isothermal elastic moduli and coefficient of thermal expansion were monitored throughout the TMF tests. The results indicated TMF life trends which contrasted those established in a comparable (0 deg) system, as TMF loading of the (90 deg) TMC was not found to be 'life-limiting' in comparison to maximum temperature isothermal conditions. In-phase lives were very similar to those established under 427 C isothermal conditions. High stress isothermal fatigue at 427 C produced increased strain ratchetting and stiffness degradation relative to TMF conditions. Out-of-phase loadings produced TMF lives approximately an order of magnitude greater than the lives determined under isothermal and in-phase conditions. Extensive fractography and metallography were also performed. Two key issues were identified and appeared to dominate the fatigue damage and life of the (90 deg) TMC, namely, the weak fiber/matrix interface and environmental attack of the fiber/matrix interface via the exposed (90 deg) fiber ends.
Detecting Gear Tooth Fatigue Cracks in Advance of Complete Fracture
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.; Lewicki, David G.
1996-01-01
Results of using vibration-based methods to detect gear tooth fatigue cracks are presented. An experimental test rig was used to fail a number of spur gear specimens through bending fatigue. The gear tooth fatigue crack in each test was initiated through a small notch in the fillet area of a tooth on the gear. The primary purpose of these tests was to verify analytical predictions of fatigue crack propagation direction and rate as a function of gear rim thickness. The vibration signal from a total of three tests was monitored and recorded for gear fault detection research. The damage consisted of complete rim fracture on the two thin rim gears and single tooth fracture on the standard full rim test gear. Vibration-based fault detection methods were applied to the vibration signal both on-line and after the tests were completed. The objectives of this effort were to identify methods capable of detecting the fatigue crack and to determine how far in advance of total failure positive detection was given. Results show that the fault detection methods failed to respond to the fatigue crack prior to complete rim fracture in the thin rim gear tests. In the standard full rim gear test all of the methods responded to the fatigue crack in advance of tooth fracture; however, only three of the methods responded to the fatigue crack in the early stages of crack propagation.
Ratcheting induced cyclic softening behaviour of 42CrMo4 steel
NASA Astrophysics Data System (ADS)
Kreethi, R.; Mondal, A. K.; Dutta, K.
2015-02-01
Ratcheting is an important field of fatigue deformation which happens under stress controlled cyclic loading of materials. The aim of this investigation is to study the uniaxial ratcheting behavior of 42CrMo4 steel in annealed condition, under various applied stresses. In view of this, stress controlled fatigue tests were carried out at room temperature up to 200 cycles using a servo-hydraulic universal testing machine. The results indicate that accumulation of ratcheting strain increases monotonically with increasing maximum applied stress however; the rate of strain accumulation attains a saturation plateau after few cycles. The investigated steel shows cyclic softening behaviour under the applied stress conditions. The nature of strain accumulation and cyclic softening has been discussed in terms of dislocation distribution and plastic damage incurred in the material.
Major Effects of Nonmetallic Inclusions on the Fatigue Life of Disk Superalloy Demonstrated
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Telesman, Jack; Kantzos, Peter T.; Bonacuse, Peter J.; Barrie, Robert L.
2002-01-01
The fatigue properties of modern powder metallurgy disk alloys can vary because of the different steps of materials and component processing and machining. Among these variables, the effects of nonmetallic inclusions introduced during the powder atomization and handling processes have been shown to significantly degrade low-cycle fatigue life. The levels of inclusion contamination have, therefore, been reduced to less than 1 part per million in state-of-the-art nickel disk powder-processing facilities. Yet the large quantities of compressor and turbine disks weighing from 100 to over 1000 lb have enough total volume and surface area for these rare inclusions to still be present and limit fatigue life. The objective of this study was to investigate the effects on fatigue life of these inclusions, as part of the Crack Resistant Disk Materials task within the Ultra Safe Propulsion Project. Inclusions were carefully introduced at elevated levels in a nickel-base disk superalloy, U720, produced using powder metallurgy processing. Multiple strain-controlled fatigue tests were then performed on extracted test specimens at 650 C. Analyses were performed to compare the low-cycle fatigue lives and failure initiation sites as functions of inclusion content and fatigue conditions. Powder of the nickel-base superalloy U720 was atomized in argon at Special Metals Corporation, Inc., using production-scale high-cleanliness powder-processing facilities and handling practices. The powder was then passed through a 270-mesh screen. One portion of this powder was set aside for subsequent consolidation without introduced inclusions. Two other portions of this powder were seeded with alumina inclusions. Small, polycrystalline soft (Type 2) inclusions of about 50 mm diameter were carefully prepared and blended into one powder lot, and larger hard (Type 1) inclusions of about 150 mm mean diameter were introduced into the other seeded portion of powder. All three portions of powder were then sealed in separate containers, hot isostatically pressurized, extruded, forged into subscale disks, and heat treated. Low-cycle-fatigue specimens were then extracted, machined, and tested. Fatigue tests were performed at 650 C in closed-loop servohydraulic testing machines using induction heating and axial extensometers. All tests were continued to failure, and fractographic evaluations were performed on all specimens to determine the crack initiation sites. A large majority of the failures in specimens with introduced inclusions occurred at cracks initiating from inclusions at the specimen surface, as shown for each type of inclusion in the following bar chart. The inclusions significantly reduced fatigue life from unseeded material levels, as shown in the bar chart. These effects were found to depend on the strain range, strain ratio, and inclusion size. Tests at lower strain ranges and higher strain ratios resulted in larger effects of inclusions on life. Inclusion effects on life were thereby maximized in tests at the lowest strain range of 0.6 percent and the most positive strain ratio of 0.5. Under these conditions, small Type 2 inclusions reduced life substantially-- about 20 times, whereas large Type 1 inclusions dramatically reduced life 100 times. These results clearly demonstrate that it is essential to include the effects of inclusions for realistic predictions of disk fatigue life. Important issues, including temperature dependence, crack initiation versus propagation, surface treatments, realistic disk features and machining, and realistic disk spin testing will be addressed to accurately model inclusion effects on disk fatigue life. Fatigue life varied from well over 105 cycles for no inclusions to a little over 103 cycles for 100-micrometer inclusions. A single crack initiating at a surface-connected seeded inclusion caused failure in each case.
Armbrust, Wineke; Lelieveld, Otto H T M; Tuinstra, Jolanda; Wulffraat, Nico M; Bos, G J F Joyce; Cappon, Jeannette; van Rossum, Marion A J; Sauer, Pieter J J; Hagedoorn, Mariët
2016-12-06
Fatigue is common in patients with JIA and affects daily life negatively. We assessed the presence and severity of fatigue in patients with JIA, including factors presumed associated with fatigue (e.g., disease activity, disability, pain, physical activity, exercise capacity, and self-efficacy), and whether fatigue is related to participation in physical education classes, school attendance, and sports frequency. The current study used baseline data of 80 patients with JIA (age 8-13) who participated in an intervention aimed at promoting physical activity. Primary outcome measurements were fatigue, assessed using the Pediatric-Quality-of-Life-Inventory (PedsQl)-Fatigue-scale and energy level assessed using a VAS scale. Other outcome measurements were disease activity (VAS Physician Global Assessment Scale), disability (Childhood Health Assessment Questionnaire), physical activity (accelerometer), exercise capacity (Bruce treadmill test), self-efficacy (Childhood Arthritis Self-Efficacy Scale), and participation (self-report). Sixty percent of patients with JIA suffered from daily low-energy levels; 27% suffered from very low-energy levels more than half the week. Low energy levels were best predicted by disability and low physical activity. Fatigue measured with the PEDsQL was higher compared to the control-population. Disability and low self-efficacy were main predictors of fatigue. Self-efficacy was a predictor of fatigue but did not act as moderator. Fatigue was a predictor for sports frequency but not for school attendance. Fatigue is a significant problem for JIA patients. Interventions aimed at reducing perceived disability, stimulating physical activity, and enhancing self-efficacy might reduce fatigue and thereby enhance participation. Trial number ISRCTN92733069.
Taso, Chao-Jung; Lin, Huey-Shyan; Lin, Wen-Li; Chen, Shu-Ming; Huang, Wen-Tsung; Chen, Shang-Wen
2014-09-01
Depression, anxiety, and fatigue are among the most significant problems that influence the quality of life of patients with breast cancer who receive adjuvant chemotherapy. Although evidence has shown yoga to decrease anxiety, depression, and fatigue in patients with cancer, few studies on the effects of yoga have targeted patients with breast cancer. Yoga interventions should be tested to promote the psychological and physical health of women with breast cancer. This study examines the effectiveness of an 8-week yoga exercise program in promoting the psychological and physical health of women with breast cancer undergoing adjuvant chemotherapy in terms of depression, anxiety, and fatigue. A sample of 60 women with nonmetastatic breast cancer was recruited. Participants were randomly assigned into either the experimental group (n = 30) or the control group (n = 30). A 60-minute, twice-per-week yoga exercise was implemented for 8 weeks as the intervention for the participants in the experimental group. The control group received standard care only. Analysis using the Johnson-Neyman procedure found that the yoga exercise reduced overall fatigue and the interference of fatigue in everyday life for the experimental group participants. Significant reductions were obtained after 4 weeks of intervention participation for those experimental group patients with relatively low starting baseline values (baseline item mean value < 3.31 and 3.22, respectively) and after 8 weeks for most patients (approximately 75%) with moderate starting baseline values (baseline item mean value < 7.30 and 5.34, respectively). The 8-week intervention did not significantly improve the levels of depression (F = 1.29, p > .05) or anxiety (F = 2.7, p > .05). The 8-week yoga exercise program developed in this study effectively reduced fatigue in patients with breast cancer but did not reduce depression or anxiety. Oncology nurses should strengthen their clinical health education and apply yoga to reduce the fatigue experienced by patients with breast cancer who undergo adjuvant chemotherapy.
Comments on the origin of acoustic emission in fatigue testing of aluminum alloys
NASA Astrophysics Data System (ADS)
Heiple, C. R.; Carpenter, S. H.; Armentrout, D. L.
The size of acoustic emission (AE) signals expected from inclusion fracture during fatigue testing of 7075 aluminum has been estimated on the basis of previous measurements of AE produced by the fracture of boron particles incorporated into 2219 aluminum. The AF signal size expected from deformation in the plastic zone ahead of the fatigue crack was estimated from the results of tensile tests on 7075 aluminum. The signals predicted from both processes are near or below the noise level in the fatigue experiments and are therefore far too small to account for the signals actually observed. Nearly simultaneous fracture of multiple inclusions could produce signals as large as those observed in fatigue tests of 7075 aluminum, however, fatigue tests of 7050 aluminum produced signals as large or larger than in 7075. Since 7050 has substantially fewer inclusions than 7075, the simultaneous failure of multiple inclusions is unlikely to be a major AE source in fatigue testing of either aluminum alloy. Thus, the most probable source of acoustic emission during fatigue testing of 7075 and 7050 aluminum is the crack advance itself. The measured crack advance per cycle is large enough to release sufficient elastic energy to account for the AE signals observed.
Moss-Morris, Rona; McCrone, Paul; Yardley, Lucy; van Kessel, Kirsten; Wills, Gary; Dennison, Laura
2012-06-01
The majority of people affected by Multiple Sclerosis (paMS) experience severe and disabling fatigue. A recent randomised controlled trial (RCT) showed that cognitive behaviour therapy with a clinical psychologist was an effective treatment for MS fatigue. An Internet-based version of this intervention, MS Invigor8, was developed for the current study using agile design and input from paMS. MS Invigor8 includes eight tailored, interactive sessions. The aim was to test the feasibility and potential efficacy and cost-effectiveness of the programme in a pilot RCT. 40 patients were randomised to MS Invigor8 (n=23) or standard care (n=17). The MS Invigor8 group accessed sessions over 8-10 weeks and received up to three 30-60min telephone support sessions. Participants completed online standardised questionnaires assessing fatigue, mood, quality of life and service use at baseline and 10 weeks follow-up. Large between group treatment effects were found for the primary outcomes of fatigue severity (d=1.19) and impact (d=1.02). The MS Invigor8 group also reported significantly greater improvements in anxiety, depression and quality-adjusted life years. These data suggest that Internet-based CBT may be a clinically and cost-effective treatment for MS fatigue. A larger RCT with longer term follow-up is warranted. Copyright © 2012 Elsevier Ltd. All rights reserved.
Evaluating Fatigue in Operational Settings: The NASA Ames Fatigue Countermeasures Program
NASA Technical Reports Server (NTRS)
Rosekind, Mark R.; Gregory, Kevin; Miller, Donna; Webbon, Lissa; Oyung, Ray
1996-01-01
In response to a 1980 Congressional request, NASA Ames initiated a program to examine fatigue in flight operations. The Program objectives are to examine fatigue, sleep loss, and circadian disruption in flight operations, determine the effects of these factors on flight crew performance, and the development of fatigue countermeasures. The NASA Ames Fatigue Countermeasures Program conducts controlled laboratory experiments, full-mission flight simulations, and field studies. A range of subjective, behavioral, performance, physiological, and environmental measures are used depending on study objectives. The Program has developed substantial expertise in gathering data during actual flight operations and in other work settings. This has required the development of ambulatory and other measures that can be carried throughout the world and used at 41,000 feet in aircraft cockpits. The NASA Ames Fatigue Countermeasures Program has examined fatigue in shorthaul, longhaul, overnight cargo, and helicopter operations. A recent study of planned cockpit rest periods demonstrated the effectiveness of a brief inflight nap to improve pilot performance and alertness. This study involved inflight reaction time/vigilance performance testing and EEG/EOG measures of physiological alertness. The NASA Ames Fatigue Countermeasures Program has applied scientific findings to the development of education and training materials on fatigue countermeasures, input to federal regulatory activities on pilot flight, duty, and rest requirements, and support of National Transportation Safety Board accident investigations. Current activities are examining fatigue in nonaugmented longhaul flights, regional/commuter flight operations, corporate/business aviation, and psychophysiological variables related to performance.
2013-01-01
Background The etiology of fibromyalgia and chronic fatigue syndrome (FM/CFS) is currently unknown. A recurrent viral infection is an attractive hypothesis repeatedly found in the literature since it would explain the persistent pain and tiredness these patients suffer from. The initial striking link of two distinct orphan retroviruses: the gamma retroviruses murine leukemia virus (MLV)-related virus and the delta retrovirus T-lymphotropic virus type 2 (HTLV-2) to chronic fatigue have not been confirmed to date. Results Genomic DNA (gDNA) from 75 fibromyalgia patients suffering from chronic fatigue and 79 age-matched local healthy controls were screened for the presence of MLV-related and HTLV-2 related proviral sequences. The XMRV env gene was amplified in 20% of samples tested (24% patients/15% healthy controls). Unexpectedly, no PCR amplifications from independent gDNA preparations of the same individuals were obtained. None of the positive samples showed presence of contaminating murine sequences previously reported by other investigators, neither contained additional regions of the virus making us conclude that the initial env amplification came from spurious air-driven amplicon contaminants. No specific HTLV-2 sequences were obtained at any time from any of the 154 quality-controlled gDNA preparations screened. Conclusions Previous associations between MLV-related or HTLV-2 retrovirus infection with chronic fatigue must be discarded. Thus, studies showing positive amplification of HTLV-2 sequences from chronic fatigue participants should be revised for possible undetected technical problems. To avoid false positives of viral infection, not only extreme precautions should be taken when nested-PCR reactions are prepared and exhaustive foreign DNA contamination controls performed, but also consistent amplification of diverse regions of the virus in independent preparations from the same individual must be demanded. The fact that our cohort of patients did not present evidence of any of the two types of retroviral infection formerly associated to chronic fatigue does not rule out the possibility that other viruses are involved in inciting or maintaining fibromyalgia and/or chronic fatigue conditions. PMID:24216038
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... describes the unsafe condition as: As a result of the fatigue-testing programme on the Jetstream fatigue... result of the fatigue-testing programme on the Jetstream fatigue test specimen, it has been identified....S. registry. We also estimate that it will take about 15 work-hours per product to comply with the...
A literature review and inventory of the effects of environment on the fatigue behavior of metals
NASA Technical Reports Server (NTRS)
Hudson, C. M.; Seward, S. K.
1976-01-01
The current state of knowledge of the effects of gas environments (at atmospheric pressure and below) on the fatigue behavior of metals is reviewed. Among the topics considered are the mechanisms proposed to explain the differences observed in the fatigue behavior of vacuum- and air-tested specimens, the effects of environment on the surface topography of fatigue cycled specimens, the effect of environment on the various phases of the fatigue phenomenon, the effect of prolonged exposure to vacuum on fatigue life, the variation of fatigue life with decreasing gas pressure, and gas evolution during fatigue cycling. Analysis of the findings of this review indicates that hydrogen embrittlement is primarily responsible for decreased fatigue resistance in humid environments, and that dislocations move more easily during tests in vacuum than during test in air. It was found that fatigue cracks generally initiated and propagated more rapidly in air than in vacuum. Prolonged exposure to vacuum does not adversely affect fatigue resistance. The variation of fatigue life with decreasing gas pressure is sometimes stepped and sometimes continuous.
Fatigue Behavior of Steel Fiber Reinforced High-Strength Concrete under Different Stress Levels
NASA Astrophysics Data System (ADS)
Zhang, Chong; Gao, Danying; Gu, Zhiqiang
2017-12-01
The investigation was conducted to study the fatigue behavior of steel fiber reinforced high-strength concrete (SFRHSC) beams. A series of 5 SFRHSC beams was conducted flexural fatigue tests at different stress level S of 0.5, 0.55, 0.6, 0.7 and 0.8 respectively. Static test was conducted to determine the ultimate static capacity prior to fatigue tests. Fatigue modes and S-N curves were analyzed. Besides, two fatige life prediction model were analyzed and compared. It was found that stress level S significantly influenced the fatigue life of SFRHSC beams and the fatigue behavior of SFRHSC beams was mainly determined by the tensile reinforcement.
Fatigue Life Methodology for Bonded Composite Skin/Stringer Configurations
NASA Technical Reports Server (NTRS)
Krueger, Ronald; Paris, Isabelle L.; OBrien, T. Kevin; Minguet, Pierre J.
2001-01-01
A methodology is presented for determining the fatigue life of composite structures based on fatigue characterization data and geometric nonlinear finite element (FE) analyses. To demonstrate the approach, predicted results were compared to fatigue tests performed on specimens which represented a tapered composite flange bonded onto a composite skin. In a first step, tension tests were performed to evaluate the debonding mechanisms between the flange and the skin. In a second step, a 2D FE model was developed to analyze the tests. To predict matrix cracking onset, the relationship between the tension load and the maximum principal stresses transverse to the fiber direction was determined through FE analysis. Transverse tension fatigue life data were used to -enerate an onset fatigue life P-N curve for matrix cracking. The resulting prediction was in good agreement with data from the fatigue tests. In a third step, a fracture mechanics approach based on FE analysis was used to determine the relationship between the tension load and the critical energy release rate. Mixed mode energy release rate fatigue life data were used to create a fatigue life onset G-N curve for delamination. The resulting prediction was in good agreement with data from the fatigue tests. Further, the prediction curve for cumulative life to failure was generated from the previous onset fatigue life curves. The results showed that the methodology offers a significant potential to Predict cumulative fatigue life of composite structures.
Mathiassen, Svend Erik; Hallman, David M.; Lyskov, Eugene; Hygge, Staffan
2014-01-01
Neurophysiologic theory and some empirical evidence suggest that fatigue caused by physical work may be more effectively recovered during “diverting” periods of cognitive activity than during passive rest; a phenomenon of great interest in working life. We investigated the extent to which development and recovery of fatigue during repeated bouts of an occupationally relevant reaching task was influenced by the difficulty of a cognitive activity between these bouts. Eighteen male volunteers performed three experimental sessions, consisting of six 7-min bouts of reaching alternating with 3 minutes of a memory test differing in difficulty between sessions. Throughout each session, recordings were made of upper trapezius muscle activity using electromyography (EMG), heart rate and heart rate variability (HRV) using electrocardiography, arterial blood pressure, and perceived fatigue (Borg CR10 scale and SOFI). A test battery before, immediately after and 1 hour after the work period included measurements of maximal shoulder elevation strength (MVC), pressure pain threshold (PPT) over the trapezius muscles, and a submaximal isometric contraction. As expected, perceived fatigue and EMG amplitude increased during the physical work bouts. Recovery did occur between the bouts, but fatigue accumulated throughout the work period. Neither EMG changes nor recovery of perceived fatigue during breaks were influenced by cognitive task difficulty, while heart rate and HRV recovered the most during breaks with the most difficult task. Recovery of perceived fatigue after the 1 hour work period was also most pronounced for the most difficult cognitive condition, while MVC and PPT showed ambiguous patterns, and EMG recovered similarly after all three cognitive protocols. Thus, we could confirm that cognitive tasks between bouts of fatiguing physical work can, indeed, accelerate recovery of some factors associated with fatigue, even if benefits may be moderate and some responses may be equivocal. Our results encourage further research into combinations of physical and mental tasks in an occupational context. PMID:25375644
Effects of High Mean Stress on High-cycle Fatigue Behavior of PWA 1480
NASA Technical Reports Server (NTRS)
Majumdar, S.; Antolovich, S. D.; Milligan, W. W.
1985-01-01
PWA 1480 is a potential candidate material for use in the high-pressure fuel turbine blade of the space shuttle main engine. As an engine material it will be subjected to high-cycle fatigue loading superimposed on a high mean stress due to combined centrifugal and thermal loadings. The present paper describes the results obtained in an ongoing program at the Argonne National Laboratory, sponsored by NASA Lewis, to determine the effects of a high mean stress on the high-cycle fatigue behavior of this material. Straight-gauge high-cycle fatigue specimens, 0.2 inch in diameter and with the specimen axis in the 001 direction, were supplied by NASA Lewis. The nominal room temperature yield and ultimate strength of the material were 146 and 154 ksi, respectively. Each specimen was polished with 1-micron diamond paste prior to testing. However, the surface of each specimen contained many pores, some of which were as large as 50 micron. In the initial tests, specimens were subjected to axial-strain-controlled cycles. However, very little cyclic plasticity was observed.
Effect of nitrogen on high temperature low cycle fatigue behaviors in type 316L stainless steel
NASA Astrophysics Data System (ADS)
Kim, Dae Whan; Ryu, Woo-Seog; Hong, Jun Hwa; Choi, Si-Kyung
1998-04-01
Strain-controlled low cycle fatigue (LCF) tests were conducted in the temperature range of RT-600°C and air atmosphere to investigate the nitrogen effect on LCF behavior of type 316L stainless steels with different nitrogen contents (0.04-0.15%). The waveform of LCF was a symmetrical triangle with a strain amplitude of ±0.5% and a constant strain rate of 2×10 -3/s was employed for most tests. Cyclic stress response of the alloys exhibited a gradual cyclic softening at RT, but a cyclic hardening at an early stage of fatigue life at 300-600°C. The hardening at high temperature was attributed to dynamic strain aging (DSA). Nitrogen addition decreased hardening magnitude (maximum cyclic stress — first cyclic stress) because nitrogen retarded DSA for these conditions. The dislocation structures were changed from cell to planar structure with increasing temperature and nitrogen addition by DSA and short range order (SRO). Fatigue life was a maximum at 0.1% nitrogen content, which was attributed to the balance between DSA and SRO.
Larson, Dennis J; Brown, Stephen H M
2018-02-01
The purpose of this study was to induce both trunk extensor and abdominal muscle fatigue, on separate occasions, and compare their effects on standing postural control and trunk proprioception, as well as look at the effects of a recovery period on these outcome measures. A total of 20 individuals participated, with 10 (5 males and 5 females) completing either a standing postural control or lumbar axial repositioning protocol. Participants completed their randomly assigned protocol on two occasions, separated by at least 4 days, with either their trunk extensor or abdominal muscles being fatigued on either day. Postural control centre of pressure variables and trunk proprioception errors were compared pre- and post-fatigue. Results showed that both trunk extensor and abdominal muscle fatigue significantly degraded standing postural control immediately post-fatigue, with recovery occurring within 2 min post-fatigue. In general, these degradative effects on postural control appeared to be greater when the trunk extensor muscles were fatigued compared to the abdominal muscles. No statistically significant changes in trunk proprioception were found after either fatigue protocol. The present findings demonstrate our body's ability to quickly adapt and reweight somatosensory information to maintain postural control and trunk proprioception, as well as illustrate the importance of considering the abdominal muscles, along with the trunk extensor muscles, when considering the impact of fatigue on trunk movement and postural control. Copyright © 2017 Elsevier B.V. All rights reserved.
High-temperature, low-cycle fatigue behavior of an Al-Mg-Si based heat-resistant aluminum alloy
NASA Astrophysics Data System (ADS)
Kim, Kyu-Sik; Sung, Si-Young; Han, Bum-Suck; Park, Joong-Cheol; Lee, Kee-Ahn
2015-11-01
High-temperature, low-cycle fatigue behavior of the new heat-resistant aluminum alloy was investigated in this study. The aluminum alloy consists of aluminum matrix and small amount of precipitated Mg2Si and (Co, Ni)3Al4 strengthening particles. At room temperature and 523 K, the yield and tensile strengths of Al-Mg-Si-(Co, Ni) the aluminum alloy were maintained with no significant decrease, and elongation increased slightly. Low-cycle fatigue tests controlled by total strain were performed with strain ratio (R) = -1, strain rate = 2×10-3 s-1 at 523 K. The fatigue limit of the low-cycle fatigue of this alloy showed plastic strain amplitude (Δ ɛ pa) of 0.22% at 103 cycles. This value was superior to that of conventional aluminum alloy such as A319. The results of the fractographical observation showed that second phases, especially (Co, Ni)3Al4 particles, affected fatigue behavior. This study also attempted to clarify the mechanism of high-temperature, low-cycle fatigue deformation of Al-Mg-Si-(Co, Ni) alloy in relation to its microstructure and energy dissipation analysis.
NASA Astrophysics Data System (ADS)
Chen, Zhi-kai; Lu, Shu-chao; Song, Xi-bin; Zhang, Haifeng; Yang, Wan-shi; Zhou, Hong
2015-03-01
To improve the fatigue wear resistance of gray cast iron (GCI), GCI samples were modified by a laser to imitate the unique structure of some soil animals alternating between soft and hard phases; the hard phase resists the deformation and the soft phase releases the deformation. Using the self-controlled fatigue wear test method, the fatigue wear behaviors of treated and untreated samples were investigated and compared experimentally. The results show that the bionic non-smooth surface obtains a beneficial effect on improving the fatigue wear resistance of a sample, and the fatigue wear resistance of the bionic sample assembled with reticulate units (60°+0°), whose mass loss was reduced by 62%, was superior to the others. Meanwhile, a finite element (FE) was used to simulate the compression and the distributions of strain and stress on the non-smooth surface was inferred. From these results, we understood that the functions of the bionic unit such as reducing strain and stress, and also obstructing the closure and propagation of cracks were the main reasons for improving the fatigue wear property of GCI.
Alibazi, Razie J; Moghadam, Afsun Nodehi; Cools, Ann M; Bakhshi, Enayatollah; Ahari, Alireza Aziz
2017-12-01
Muscle fatigue is considered to be one cause of shoulder pain, and subjects with generalized joint hypermobility (GJH) are affected more by shoulder pain. The purpose of this study was to examine the effects of muscle fatigue on acromiohumeral distance (AHD) and scapular dyskinesis in women with GJH. Thirty-six asymptomatic participants were assigned to either a GJH (n = 20) or control group (n = 16) using the Beighton scale. Before and after elevation fatigue trials, AHD was measured with ultrasonography at rest and when the arm was in 90° active elevation. A scapular dyskinesis test was used to visually observe alterations in scapular movement. Our results showed that in both groups, the fatigue reduced AHD in the 90° elevation position and increased the presence of scapular dyskinesis; however, no differences were found between the two groups. Although GJH has been identified as a factor for developing musculoskeletal disorders, generalized joint hypermobility did not result in changes to scapular dyskinesis or AHD, even after an elevation fatigue task. More studies are needed to evaluate the effects of muscle fatigue in subjects with GJH and a history of shoulder instability.
Dailey, Dana L; Rakel, Barbara A; Vance, Carol G T; Liebano, Richard E; Amrit, Anand S; Bush, Heather M; Lee, Kyoung S; Lee, Jennifer E; Sluka, Kathleen A
2013-11-01
Because transcutaneous electrical nerve stimulation (TENS) works by reducing central excitability and activating central inhibition pathways, we tested the hypothesis that TENS would reduce pain and fatigue and improve function and hyperalgesia in people with fibromyalgia who have enhanced central excitability and reduced inhibition. The current study used a double-blinded randomized, placebo-controlled cross-over design to test the effects of a single treatment of TENS with people with fibromyalgia. Three treatments were assessed in random order: active TENS, placebo TENS and no TENS. The following measures were assessed before and after each TENS treatment: pain and fatigue at rest and in movement; pressure pain thresholds, 6-m walk test, range of motion; 5-time sit-to-stand test, and single-leg stance. Conditioned pain modulation was completed at the end of testing. There was a significant decrease in pain and fatigue with movement for active TENS compared to placebo and no TENS. Pressure pain thresholds increased at the site of TENS (spine) and outside the site of TENS (leg) when compared to placebo TENS or no TENS. During active TENS, conditioned pain modulation was significantly stronger compared to placebo TENS and no TENS. No changes in functional tasks were observed with TENS. Thus, the current study suggests TENS has short-term efficacy in relieving symptoms of fibromyalgia while the stimulator is active. Future clinical trials should examine the effects of repeated daily delivery of TENS, similar to the way in which TENS is used clinically on pain, fatigue, function, and quality of life in individuals with fibromyalgia. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Fatigue in young survivors of extracranial childhood cancer: a Finnish nationwide survey.
Mört, Susanna; Lähteenmäki, Päivi M; Matomäki, Jaakko; Salmi, Toivo T; Salanterä, Sanna
2011-11-01
To evaluate self-reports of fatigue by young cancer survivors (aged 11-18 years), to compare young survivors' fatigue scores with the scores of a healthy control group and of the parent proxy evaluation, and to analyze whether demographic or disease-related factors are associated with young survivors' fatigue. Cross-sectional quantitative study. An urban hospital in southwestern Finland. 384 survivors diagnosed with an extracranial malignancy at age 16 or younger, who have survived four or more years postdiagnosis, and who are free of cancer. General matched population controls were randomly selected from the Finnish Population Registry. Demographic data and a self-report written fatigue questionnaire. Total fatigue (TF), general fatigue (GF), sleep or rest fatigue (SF), and cognitive fatigue. The control populations reported significantly more issues with TF, GF, and SF than did the survivor population. In survivors, older age, the need for remedial education at school, and a sarcoma diagnosis were associated with increasing fatigue, whereas female gender, better school grades, and greater health-related quality-of-life (HRQOL) scores were associated with lower fatigue. The study variables explained 49%-65% of the variation in fatigue scores. Although survivors and their matched controls seem to have similar fatigue, subgroups of survivors do experience excessive fatigue, which may have an impact on their HRQOL. This study increases the knowledge about fatigue levels of young survivors of extracranial malignancies and identifies the need for instruments specifically designed to assess fatigue in this population. The healthcare team should pay attention to the fatigue level of young survivors, particularly SF.
NASA Astrophysics Data System (ADS)
Amiri, Ali
Carbon fiber reinforced polymers (CFRP) have become an increasingly notable material for use in structural engineering applications. Some of their advantages include high strength-to-weight ratio, high stiffness-to-weight ratio, and good moldability. Prediction of the fatigue life of composite laminates has been the subject of various studies due to the cyclic loading experienced in many applications. Both theoretical studies and experimental tests have been performed to estimate the endurance limit and fatigue life of composite plates. One of the main methods to predict fatigue life is the four-point bending test. In most previous works, the tests have been done in one direction (load ratio, R, > 0). In the current work, we have designed and manufactured a special fixture to perform a fully reversed bending test (R = -1). Static four-point bending tests were carried out on three (0°/90°)15 and (± 45°)15 samples to measure the mechanical properties of CFRP. Testing was displacement-controlled at the rate of 10 mm/min until failure. In (0°/90°)15 samples, all failed by cracking/buckling on the compressive side of the sample. While in (± 45°)15 all three tests, no visual fracture or failure of the samples was observed. 3.4 times higher stresses were reached during four-point static bending test of (0° /90°)15 samples compared to (± 45°)15. Same trend was seen in literature for similar tests. Four-point bending fatigue tests were carried out on (0° /90°)15 sample with stress ratio, R = -1 and frequency of 5 Hz. Applied maximum stresses were approximately 45%, 56%, 67%, 72% and 76% of the measured yield stress for (0° /90°)15 samples. There was visible cracking through the thickness of the samples. The expected downward trend in fatigue life with increasing maximum applied stress was observed in S-N curves of samples. There appears to be a threshold for ‘infinite’ life, defined as 1.7 million cycles in the current work, at a maximum stress of about 200 MPa. The decay in flexural modulus of the beam as it goes under cyclic loading was calculated and it was seen that flexural modulus shows an exponential decay which can be expressed as: E = E0e AN. Four-point bending fatigue tests were carried out on three (±45°)15 samples with stress ratio, R = -1 and frequency of 5 Hz. Maximum applied stress was 85% of the measured yield stress of (±45°)15 samples. None of the samples failed, nor any sign of crack was seen. Tests were stopped once the number of cycles passed 1.7×106. In general, current study provided additional insight into the fatigue and static behavior of polymer composites and effect of fiber orientation in their mechanical behavior.
Sterling, Amanda J; Torries, Brian; Shamsaei, Nima; Thompson, Scott M
2016-03-01
Data is presented describing the strain-controlled, fully-reversed uniaxial cyclic deformation and fatigue behavior of Ti-6Al-4V specimens additively manufactured via Laser Engineered Net Shaping (LENS) - a Direct Laser Deposition (DLD) process. The data was collected by performing multiple fatigue tests on specimens with various microstructural states/conditions, i.e. in their 'as-built', annealed (below the beta transus temperature), or heat treated (above the beta transus temperature) condition. Such data aids in characterizing the mechanical integrity and fatigue resistance of DLD parts. Data presented herein also allows for elucidating the strong microstructure coupling of the fatigue behavior of DLD Ti-6Al-4V, as the data trends were found to vary with material condition (i.e. as-built, annealed or heat treated) [1]. This data is of interest to the additive manufacturing and fatigue scientific communities, as well as the aerospace and biomedical industries, since additively-manufactured parts cannot be reliably deployed for public use, until their mechanical properties are understood with high certainty.
Sterling, Amanda J.; Torries, Brian; Shamsaei, Nima; Thompson, Scott M.
2016-01-01
Data is presented describing the strain-controlled, fully-reversed uniaxial cyclic deformation and fatigue behavior of Ti–6Al–4V specimens additively manufactured via Laser Engineered Net Shaping (LENS) – a Direct Laser Deposition (DLD) process. The data was collected by performing multiple fatigue tests on specimens with various microstructural states/conditions, i.e. in their ‘as-built’, annealed (below the beta transus temperature), or heat treated (above the beta transus temperature) condition. Such data aids in characterizing the mechanical integrity and fatigue resistance of DLD parts. Data presented herein also allows for elucidating the strong microstructure coupling of the fatigue behavior of DLD Ti–6Al–4V, as the data trends were found to vary with material condition (i.e. as-built, annealed or heat treated) [1]. This data is of interest to the additive manufacturing and fatigue scientific communities, as well as the aerospace and biomedical industries, since additively-manufactured parts cannot be reliably deployed for public use, until their mechanical properties are understood with high certainty. PMID:26949728
Effects of EVA gloves on grip strength and fatigue under low temperature and low pressure.
Tian, Yinsheng; Ding, Li; Liu, Heqing; Li, Yan; Li, Deyu; Wang, Li
2016-03-01
To study the effects of wearing extravehicular activity (EVA) gloves on grip strength and fatigue in low temperature, low pressure and mixing of two factors (low temperature and low pressure). The maximum grip strength and fatigue tests were performed with 10 healthy male subjects wearing gloves in a variety of simulated environments. The data was analysed using the normalization method. The results showed that wearing gloves significantly affected the maximum grip strength and fatigue. Pressure (29.6, 39.2 kPa) had more influence on the maximum grip compared with control group while low temperatures (-50, -90, -110 °C) had no influence on grip but affected fatigue dramatically. The results also showed that the maximum grip strength and fatigue were influenced significantly in a compound environment. Space environment remarkably reduced strength and endurance of the astronauts. However, the effects brought by the compound environment cannot be understood as the superimposition of low temperature and pressure effects. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Effects of caffeine ingestion on endurance performance in mentally fatigued individuals.
Azevedo, Rafael; Silva-Cavalcante, Marcos David; Gualano, Bruno; Lima-Silva, Adriano E; Bertuzzi, Romulo
2016-12-01
To examine the effects of caffeine ingestion on physiological and perceptual responses in mentally fatigued individuals. Eight male physically active subjects completed four cycling constant-workload tests in four experimental conditions at 80 % of maximal power output: control (C), mental fatigue (MF), mental fatigue plus caffeine ingestion (5 mg/kg) (MF-CAF), and mental fatigue plus placebo (MF-PLA). The mental fatigue was induced by a continuous performance task A-X version (AX-CPT). Before and after the AX-CPT, the profile of mood state (POMS) and blood samples for lactate measurement were collected. Oxygen consumption ([Formula: see text]), rating of perceived exertion (RPE), and electromyography (EMG) activity were measured during the cycling test. The time to exhaustion in C, MF, MF-PLA, and MF-CAF were 251 ± 30, 222 ± 23, 248 ± 28, and 285 ± 42 s, respectively. Delta values (corrected by C condition) were higher in MF-CAF than MF (P = 0.031). MF-CAF reported higher Vigor scores when compared with C (P = 0.046) and MF (P = 0.020). RPE at the first minute was significantly higher in MF-PLA than in C (P = 0.050); at the second minute, RPE was higher in MF-PLA than in C (P = 0.049) and MF-CAF (P = 0.048). EMG activity was not different between the conditions. Caffeine ingestion increased approximately 14 % endurance performance after the induction of mental fatigue. This effect was accompanied by a tendency to improvement in mood state (i.e., vigor). Therefore, caffeine ingestion can promote a beneficial effect on endurance performance in mentally fatigued individuals.
A Chronic Fatigue Syndrome (CFS) severity score based on case designation criteria
Baraniuk, James N; Adewuyi, Oluwatoyin; Merck, Samantha Jean; Ali, Mushtaq; Ravindran, Murugan K; Timbol, Christian R; Rayhan, Rakib; Zheng, Yin; Le, Uyenphuong; Esteitie, Rania; Petrie, Kristina N
2013-01-01
Background: Chronic Fatigue Syndrome case designation criteria are scored as physicians’ subjective, nominal interpretations of patient fatigue, pain (headaches, myalgia, arthralgia, sore throat and lymph nodes), cognitive dysfunction, sleep and exertional exhaustion. Methods: Subjects self-reported symptoms using an anchored ordinal scale of 0 (no symptom), 1 (trivial complaints), 2 (mild), 3 (moderate), and 4 (severe). Fatigue of 3 or 4 distinguished “Fatigued” from “Not Fatigued” subjects. The sum of the 8(Sum8) ancillary criteria was tested as a proxy for fatigue. All subjects had history and physical examinations to exclude medical fatigue, and ensure categorization as healthy or CFS subjects. Results: Fatigued subjects were divided into CFS with ≥4 symptoms or Chronic Idiopathic Fatigue (CIF) with ≤3 symptoms. ROC of Sum8 for CFS and Not Fatigued subjects generated a threshold of 14 (specificity=0.934; sensitivity=0.928). CFS (n=256) and CIF (n=55) criteria were refined to include Sum8≥14 and ≤13, respectively. Not Fatigued subjects had highly skewed Sum8 responses. Healthy Controls (HC; n=269) were defined by fatigue≤2 and Sum8≤13. Those with Sum8≥14 were defined as CFS–Like With Insufficient Fatigue Syndrome (CFSLWIFS; n=20). Sum8 and Fatigue were highly correlated (R2=0.977; Cronbach’s alpha=0.924) indicating an intimate relationship between symptom constructs. Cluster analysis suggested 4 clades each in CFS and HC. Translational utility was inferred from the clustering of proteomics from cerebrospinal fluid. Conclusions: Plotting Fatigue severity versus Sum8 produced an internally consistent classifying system. This is a necessary step for translating symptom profiles into fatigue phenotypes and their pathophysiological mechanisms. PMID:23390566
Lee, Young-Mee
2011-02-01
The purpose of this study was to evaluate the effects of self-foot reflexology on stress (perceived stress, urine cortisol level, and serum cortisol level), fatigue, skin temperature and immune response in female undergraduate students. The research design was a nonequivalent control group pretest-post test design. Participants were 60 university students: 30 in the experiment group and 30 in the control group. The period of this study was from April to June 2010. The program was performed for 1 hr a session, three times a week for 6 weeks. The data were analyzed using the SPSS/WIN 17.0 program. The results showed that self-foot reflexology was effective in reducing perceived stress and fatigue, and raised skin temperature in female undergraduate students. But cortisol levels and immune response were not statistically significant different. The results of this study indicate that self-foot reflexology is an effective nursing intervention in reducing perceived stress and fatigue and, in improving skin temperature. Therefore, it is recommended that this be used in clinical practice as an effective nursing intervention for in female undergraduate students.
NASA Astrophysics Data System (ADS)
Mariappan, K.; Shankar, Vani; Sandhya, R.; Prasad Reddy, G. V.; Mathew, M. D.
2013-04-01
Influence of temperature and strain rate on low cycle fatigue (LCF) behavior of modified 9Cr-1Mo ferritic martensitic steel and 1.4W-0.06Ta reduced activation ferritic martensitic (RAFM) steel in normalized and tempered conditions was studied. Total strain controlled LCF tests between 300 and 873 K on modified 9Cr-1Mo steel and RAFM steel and at various strain rates on modified 9Cr-1Mo steel were performed at total strain amplitude of ±0.6%. Both the steels showed continuous cyclic softening at all temperatures. Whereas manifestations of dynamic strain aging (DSA) were observed in both the steels which decreased fatigue life at intermediate temperatures, at higher temperatures, oxidation played a crucial role in decreasing fatigue life.
NASA Astrophysics Data System (ADS)
Lee, S. Y.; Lu, Y. L.; Liaw, P. K.; Choo, H.; Thompson, S. A.; Blust, J. W.; Browning, P. F.; Bhattacharya, A. K.; Aurrecoechea, J. M.; Klarstrom, D. L.
2008-03-01
The creep-fatigue crack-growth tests of HASTELLOY® X alloy were carried out at the temperatures of 649°C, 816°C, and 927°C in laboratory air. The experiments were conducted under a constant stress-intensity-factor-range (Δ K) control mode with a R-ratio of 0.05. In the constant Δ K tests, a Δ K of 27.5 MPa sqrt{m} and a triangular waveform with a frequency of 0.333 Hz were used. Various tensile hold times at the maximum load were imposed to study fatigue and creep-fatigue interactions. Crack lengths were measured by a direct current potential drop method. In this paper, effects of hold time and temperature on the crack-growth rates are discussed. Furthermore, the crack-growth rates of the HASTELLOY® X alloy are compared to those of the HAYNES® 188 and HAYNES® 230® superalloys.
Spectrum Fatigue of 7075-T651 Aluminum Alloy under Overloading and Underloading
2016-03-15
underload, stress ratio, and environment on fatigue crack growth. Fatigue crack growth tests were conducted with a 7075-T651 aluminum alloy under constant...the UniGrow equation, the variation of crack length with number of loading cycle was predicted. The prediction and the fatigue test life were found to...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18 REPORT NO. NAWCADPAX/TIM-2015/282 ii SUMMARY Fatigue tests of 7075-T651
Zaretsky, Dmitry V; Kline, Hannah; Zaretskaia, Maria V; Brown, Mary Beth; Durant, Pamela J; Alves, Nathan J; Rusyniak, Daniel E
2018-06-15
Stimulants cause hyperthermia, in part, by increasing heat generation through exercise. Stimulants also delay the onset of fatigue and exhaustion allowing animals to exercise longer. If used in a warm environment, this combination (increased exercise and decreased fatigue) can cause heat stroke. The dorsomedial hypothalamus (DMH) is involved in mediating locomotion from stimulants. Furthermore, inhibiting the DMH decreases locomotion and prevents hyperthermia in rats given stimulants in a warm environment. Whether the DMH is involved in mediating exercise-induced fatigue and exhaustion is not known. We hypothesized that disinhibiting neurons in the dorsomedial hypothalamus (DMH) would delay the onset of fatigue and exhaustion in animals exercising in a warm environment. To test this hypothesis, we used automated video tracking software to measure fatigue and exhaustion. In rats, using wearable mini-pumps, we demonstrated that disinhibiting the DMH, via bicuculline perfusion (5 µM), increased the duration of exercise in a warm environment as compared to control animals (25 ± 3 min vs 15 ± 2 min). Bicuculline-perfused animals also had higher temperatures at exhaustion (41.4 ± 0.2 °C vs 40.0 ± 0.4 °C). Disinhibiting neurons in the DMH also increased the time to fatigue. Our data show that the same region of the hypothalamus that is involved in mediating locomotion to stimulants, is also involved in controlling exhaustion and fatigue. These findings have implications for understanding the cause and treatment of stimulant-induced-hyperthermia. Copyright © 2018 Elsevier B.V. All rights reserved.
Harlow, Iain; Inzlicht, Michael
2017-01-01
Self-control is often believed to operate as if it were a finite, domain-general resource. However, recent attempts to demonstrate this under transparent conditions have failed to yield positive results. In the current study, we monitor two groups of students (N1 = 8,867, N2 = 8,754) over separate 17-week intervals with 24-hour coverage, as they engage in voluntary learning and self-testing using an online program. We use daily behavior to assess whether time-of-day effects support domain-general theories of self-control. Additionally, we assess whether mental fatigue emerges within task during prolonged persistent effort. Results reveal within-task fatigue emerges within an hour on-task. However, there is a negligible effect on ability throughout the day. Additionally, time-of-day has no detrimental effect on motivation; rather there is a strong tendency to increase learning time at night. Results are consistent with theories indicating people lose motivation within a specific task, but at odds with theories that argue for a domain-general self-control resource. PMID:28931013
Effects of chicken essence on recovery from mental fatigue in healthy males
Yamano, Emi; Tanaka, Masaaki; Ishii, Akira; Tsuruoka, Nobuo; Abe, Keiichi; Watanabe, Yasuyoshi
2013-01-01
Background Fatigue is a common symptom in modern society. There has been a recent resurgence of interest in traditional remedies for fatigue. Chicken essence, which is rich in anserine and carnosine, has been widely taken in Asian countries as a traditional remedy with various aims, including attenuation of physical and mental fatigue. However, the evidence for its efficacy specifically for mental fatigue remains unclear. We examined the effect of essence of chicken on mental fatigue in humans, using our established fatigue-inducing task and evaluation methods. Material/Methods In this placebo-controlled crossover study, 20 healthy male volunteers were randomized to receive daily oral administration of essence of chicken or placebo drink provided by Cerebos Pacific Ltd. via Suntory holdings Ltd. for 4 weeks. The participants performed 2-back test trials as a fatigue-inducing mental task and then had a rest session. Just before and after each session, they completed cognitive task trials focusing on selective attention to evaluate the level of mental fatigue. Results After essence of chicken intake for 1 and 4 weeks, the reaction times on the cognitive task trials after the rest session were significantly shorter than those at baseline, and significant changes were not observed with placebo intake. The reaction times before and after the fatigue-inducing session were not altered by either essence of chicken or placebo intake. Conclusions We showed that daily intake of essence of chicken could be effective for the recovery from mental fatigue and is a promising candidate for use as an anti-fatigue food. PMID:23831862
Investigation of Gear and Bearing Fatigue Damage Using Debris Particle Distributions
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Lewicki, David G.; Decker, Harry J.
2004-01-01
A diagnostic tool was developed for detecting fatigue damage to spur gears, spiral bevel gears, and rolling element bearings. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig, Spiral Bevel Gear Test Facility, and the 500hp Helicopter Transmission Test Stand. During each test, data from an online, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of pitting damage. Results indicate oil debris alone cannot discriminate between bearing and gear fatigue damage.
Evaluation of Motor Control Using Haptic Device
NASA Astrophysics Data System (ADS)
Nuruki, Atsuo; Kawabata, Takuro; Shimozono, Tomoyuki; Yamada, Masafumi; Yunokuchi, Kazutomo
When the kinesthesia and the touch act at the same time, such perception is called haptic perception. This sense has the key role in motor information on the force and position control. The haptic perception is important in the field where the evaluation of the motor control is needed. The purpose of this paper is to evaluate the motor control, perception of heaviness and distance in normal and fatigue conditions using psychophysical experiment. We used a haptic device in order to generate precise force and distance, but the precedent of the evaluation system with the haptic device has been few. Therefore, it is another purpose to examine whether the haptic device is useful as evaluation system for the motor control. The psychophysical quantity of force and distance was measured by two kinds of experiments. Eight healthy subjects participated in this study. The stimulation was presented by haptic device [PHANTOM Omni: SensAble Company]. The subjects compared between standard and test stimulation, and answered it had felt which stimulation was strong. In the result of the psychophysical quantity of force, just noticeable difference (JND) had a significant difference, and point of subjective equality (PSE) was not different between normal and muscle fatigue. On the other hand, in the result of the psychophysical quantity of distance, JND and PSE were not difference between normal and muscle fatigue. These results show that control of force was influenced, but control of distance was not influenced in muscle fatigue. Moreover, these results suggested that the haptic device is useful as the evaluation system for the motor control.
Thermal-Mechanical Fatigue Testing of a Titanium-Aluminide Alloy.
1987-12-01
DIMSTRIBUTION STA Approved for pubi robing e% dQ *- AFIT/GAB/AA/87D-18 THERMAL-MECHANICAL FATIGUE TESTING OF A TITANIUM - ALUMINIDE ALLOY THESIS John J...THERMAL-MECHANICAL FATIGUE TESTING OF A TITANIUM - ALUMINIDE ALLOY THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute...develop a Thermal-Mechanical Fatigue (TMF) testing system for titanium - aluminide compact tension specimens. I could not have accomplished this without the
Single-leg hop testing following fatiguing exercise: reliability and biomechanical analysis.
Augustsson, J; Thomeé, R; Lindén, C; Folkesson, M; Tranberg, R; Karlsson, J
2006-04-01
A fatiguing exercise protocol was combined with single-leg hop testing to improve the possibilities of evaluating the effects of training or rehabilitation interventions. In the first test-retest experiment, 11 healthy male subjects performed two trials of single-leg hops under three different test conditions: non-fatigued and following fatiguing exercise, which consisted of unilateral weight machine knee extensions at 80% and 50%, respectively, of 1 repetition maximum (1 RM) strength. Intraclass correlation coefficients ranged from 0.75 to 0.98 for different hop test conditions, indicating that all tests were reliable. For the second experiment, eight healthy male subjects performed the fatiguing exercise protocol to investigate how fatigue influences lower-extremity joint kinematics and kinetics during single-leg hops. Hip, knee and ankle joint angles, moments and powers, as well as ground-reaction forces were recorded with a six-camera, motion-capture system and a force platform. Recovery of hop performance following the fatiguing exercise was also measured. During the take-off for the single-leg hops, hip and knee flexion angles, generated powers for the knee and ankle joints, and ground-reaction forces decreased for the fatigued hop conditions compared with the non-fatigued condition (P<0.05). Compared with landing during the non-fatigued condition, hip moments and ground-reaction forces were lower for the fatigued hop conditions (P<0.05). The negative joint power was two to three times greater for the knee than for the hip and five to 10 times greater for the knee than for the ankle during landing for all test conditions (P<0.05). Most measured variables had recovered three minutes post-exercise. It is concluded that the fatiguing exercise protocol combined with single-leg hop testing was a reliable method for investigating functional performance under fatigued test conditions. Further, subjects utilized an adapted hop strategy, which employed less hip and knee flexion and generated powers for the knee and ankle joints during take-off, and less hip joint moments during landing under fatigued conditions. The large negative power values observed at the knee joint during the landing phase of the single-leg hop, during which the quadriceps muscle activates eccentrically, indicate that not only hop distance but also the ability to perform successful landings should be investigated when assessing dynamic knee function.
NASA Astrophysics Data System (ADS)
Zhou, Bing; Cui, Hao; Liu, Haibo; Li, Yang; Liu, Gaofeng; Li, Shujun; Zhang, Shangzhou
2018-03-01
The fatigue behavior of single-lap four-riveted aluminum alloy 7050 joints was investigated by using high-frequency fatigue test and scanning electron microscope (SEM). Stress distributions obtained by finite element (FE) analysis help explain the fatigue performance. The fatigue test results showed that the fatigue lives of the joints depend on cold expansion and applied cyclic loads. FE analysis and fractography indicated that the improved fatigue lives can be attributed to the reduction in maximum stress and evolution of fatigue damage at the critical location. The beneficial effects of strengthening techniques result in tearing ridges or lamellar structure on fracture surface, decrease in fatigue striations spacing, delay of fatigue crack initiation, crack deflection in fatigue crack propagation and plasticity-induced crack closure.
Fatigue Lives Of Laser-Cut Metals
NASA Technical Reports Server (NTRS)
Martin, Michael R.
1988-01-01
Fatigue lives made to approach those attainable by traditional grinding methods. Fatigue-test specimens prepared from four metallic alloys, and material removed from specimens by manual grinding, by Nd:glass laser, and by Nd:YAG laser. Results of fatigue tests of all specimens indicated reduction of fatigue strengths of laser-fired specimens. Laser machining holds promise for improved balancing of components of gas turbines.
Zhong, Lei; Zhao, Liyan; Yang, Fangmei; Yang, Wenjian; Sun, Yong; Hu, Qiuhui
2017-01-01
Fatigue is a biological phenomenon that involves a feeling of extreme physical or mental tiredness that could potentially cause some severe chronic diseases. Recently, diet therapy has provided a new alternative to alleviate physical fatigue. In our previous study, addition of Cordyceps militaris ( C. militaris ) into an extruded product was shown to provide high nutrition and unique flavors; however, little is known whether this product has some scientific evidence regarding anti-fatigue property. The purpose of this study was to evaluate the anti-fatigue effects of extruded products of cereal grains (EC) and EC mixed with C. militaris (ECC). The mice were divided into seven groups: one group received distilled water (Control group, n = 20), and the other groups received different dosages of EC (5, 10 and 20 g/kg body weight, n = 20 per group) or of ECC (5, 10 and 20 g/kg body weight, n = 20 per group) solution in water. All of the mice were administered with distilled water, EC or ECC continuously for 30 days by gavage and the anti-fatigue activity was evaluated using a weight-loaded swimming test, along with assessments of fatigue-related indicators. The mode of fighting fatigue was investigated by determining changes in exercise endurance and biochemical markers, including exhaustive swimming time, lactate dehydrogenase (LDH), blood lactic acid (BLA), creatine kinase (CK), blood urea nitrogen (BUN), malondialdehyde (MDA), glutathione peroxidase (GSH-Px), superoxide dismutase (SOD), catalase (CAT), and hepatic and muscle glycogen levels. EC and ECC prolonged the swimming endurance time of mice compared to the control. The content of BLA at high dose of ECC group (20 g/kg) was significantly lower than that in the negative control group. CK, BUN and MDA levels were significantly reduced by treatment with EC and ECC compared to the negative control, while the low and middle dose of EC had no significant effect on MDA levels. Additionally, only the middle and high dose of EC (10, 20 g/kg) could significantly decrease the BUN level. EC and ECC treatments increased glycogen, LDH, SOD, CAT and GSH-Px levels. Low and middle dose of EC had no significant effects on muscle glycogen. Moreover, low dose of EC could increase the level of SOD but it was not statistically significant. Compared to the EC treatment groups, ECC demonstrated the efficacy of anti-fatigue potential, particularly at a high dose of ECC, the best performance in relieving fatigue. These results suggest that EC and ECC could prevent exercise-induced fatigue in mice and ECC provided a better effect. In addition, C. militaris in ECC might play a crucial role in the anti-fatigue activity of ECC.
Li, Xiang-fen; Zheng, Ping; Xu, Li; Su, Qin
2015-12-01
To investigate the effects of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 types of nickel-titanium rotary instruments (K3, Mtwo, ProTaper). Three brands of NiTi rotary endodontic instruments of the same size (tip diameter 0.25 mm and constant 0.06 taper) were selected: K3, Mtwo and Protaper (F2). 24 instruments for each brand were used to evaluate the effects of autoclave sterilization on inner character in the as-received condition and after subjection to 0, 1, 5, and 10 sterilization cycles (6 for each group). Time to fracture (TtF) from the start of the test to the moment of file breakage and the length of the fractured fragment were recorded. Means and standard deviations of TtF and fragment length were calculated. The data was analyzed with SPSS13.0 software package. Another 12 NiTi rotary instruments for each brand were used, 6 subjected to 10 autoclave sterilization cycles and the other as control. Scanning electron microscope was used to observe the changes in surface topography and inner character. For cyclic fatigue resistance, when sterilization was not performed, K3 showed the highest value of TtF means and ProTaper the lowest. The differences between each brand were statistically significant (P<0.05).When disinfection was performed, K3 brand showed greater fatigue resistance in comparison with the control when autoclave sterilization cycled 5 times and 10 times. The difference between 10 cycles of sterilization and the control was statistically significant (P<0.05); ProTaper brand showed significantly greater fatigue resistance in all the disinfected groups compared with the control (P<0.05) and 5 cycles of sterilization led to the greatest increment; The fatigue resistance of Mtwo brands increased with sterilization cycles and the difference between 5/10 cycles and the control were statistically significant (P<0.05). For surface characteristics, under scanning electron microscope, surface and inner imperfections in all instruments were intensified greatly after 10 cycles of sterilization. Cycle fatigue resistance is different among instruments of different brands. Autoclave sterilization may increase fatigue resistance of the 3 brands. Autoclave sterilization may increase the surface roughness and inner defects in cross section.
NASA Technical Reports Server (NTRS)
Jaske, C. E.; Rice, R. C.; Buchheit, R. D.; Roach, D. B.; Porfilio, T. L.
1976-01-01
An investigation was conducted to assess the low-cycle fatigue resistance of two alloys, Type 347 stainless steel and Hastelloy Alloy X, that were under consideration for use in nuclear-powered rocket vehicles. Constant-amplitude, strain-controlled fatigue tests were conducted under compressive strain cycling at a constant strain rate of 0.001/sec and at total axial strain ranges of 1.5, 3.0, and 5.0 %, in both laboratory-air and low-pressure hydrogen-gas environments at temperatures from 538 to 871 C. Specimens were obtained from three heats of Type 347 stainless steel bar and two heats of Hastelloy Alloy X. The tensile properties of each heat were determined at 21, 538, 649, and 760 C. The continuous cycling fatigue resistance was determined for each heat at temperatures of 538, 760, and 871 C. The Type 347 stainless steel exhibited equal or superior fatigue resistance to the Hastelloy Alloy X at all conditions of this study.
Cognitive fatigue effects on physical performance: A systematic review and meta-analysis.
McMorris, Terry; Barwood, Martin; Hale, Beverley J; Dicks, Matt; Corbett, Jo
2018-05-01
Recent research has examined the effect that undertaking a cognitively fatiguing task for ≤90 min has on subsequent physical performance. Cognitive fatigue is claimed to affect subsequent physical performance by inducing energy depletion in the brain, depletion of brain catecholamine neurotransmitters or changes in motivation. Observation of the psychophysiology and neurochemistry literature questions the ability of 90 min' cognitive activity to deplete energy or catecholamine resources. The purpose of this study, therefore, was to examine the evidence for cognitive fatigue having an effect on subsequent physical performance. A systematic, meta-analytic review was undertaken. We found a small but significant pooled effect size based on comparison between physical performance post-cognitive fatigue compared to post-control (g = -0.27, SE = -0.12, 95% CI -0.49 to -0.04, Z(10) = -2.283, p < 0.05). However, the results were not heterogenous (Q(10) = 2.789, p > 0.10, Τ 2 < 0.001), suggesting that the pooled effect size does not amount to a real effect and differences are due to random error. No publication bias was evident (Kendall's τ = -0.07, p > 0.05). Thus, the results are somewhat contradictory. The pooled effect size shows a small but significant negative effect of cognitive fatigue, however tests of heterogeneity show that the results are due to random error. Future research should use neuroscientific tests to ensure that cognitive fatigue has been achieved. Copyright © 2018 Elsevier Inc. All rights reserved.
Combined feedforward and feedback control of a redundant, nonlinear, dynamic musculoskeletal system.
Blana, Dimitra; Kirsch, Robert F; Chadwick, Edward K
2009-05-01
A functional electrical stimulation controller is presented that uses a combination of feedforward and feedback for arm control in high-level injury. The feedforward controller generates the muscle activations nominally required for desired movements, and the feedback controller corrects for errors caused by muscle fatigue and external disturbances. The feedforward controller is an artificial neural network (ANN) which approximates the inverse dynamics of the arm. The feedback loop includes a PID controller in series with a second ANN representing the nonlinear properties and biomechanical interactions of muscles and joints. The controller was designed and tested using a two-joint musculoskeletal model of the arm that includes four mono-articular and two bi-articular muscles. Its performance during goal-oriented movements of varying amplitudes and durations showed a tracking error of less than 4 degrees in ideal conditions, and less than 10 degrees even in the case of considerable fatigue and external disturbances.