Sample records for controlled frequency detection

  1. Structural Damage Detection Using Virtual Passive Controllers

    NASA Technical Reports Server (NTRS)

    Lew, Jiann-Shiun; Juang, Jer-Nan

    2001-01-01

    This paper presents novel approaches for structural damage detection which uses the virtual passive controllers attached to structures, where passive controllers are energy dissipative devices and thus guarantee the closed-loop stability. The use of the identified parameters of various closed-loop systems can solve the problem that reliable identified parameters, such as natural frequencies of the open-loop system may not provide enough information for damage detection. Only a small number of sensors are required for the proposed approaches. The identified natural frequencies, which are generally much less sensitive to noise and more reliable than the identified natural frequencies, are used for damage detection. Two damage detection techniques are presented. One technique is based on the structures with direct output feedback controllers while the other technique uses the second-order dynamic feedback controllers. A least-squares technique, which is based on the sensitivity of natural frequencies to damage variables, is used for accurately identifying the damage variables.

  2. Hierarchical Decentralized Control Strategy for Demand-Side Primary Frequency Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, Jianming; Hansen, Jacob; Marinovici, Laurentiu D.

    The Grid Friendlymore » $$^\\textrm{TM}$$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, was designed for the purpose of autonomously switching off appliances by detecting under-frequency events. In this paper, a new frequency responsive load~(FRL) controller is first proposed by extending the functionality of the original GFA controller. The proposed FRL controller can autonomously switch on (or off) end-use loads by detecting over-frequency (or under-frequency) events through local frequency measurement. Then, a hierarchical decentralized control framework is developed for engaging the end-use loads to provide primary frequency response with the proposed FRL controller. The developed framework has several important features that are desirable in terms of providing primary frequency control. It not only exclusively maintains the autonomous operation of the end-use loads, but also effectively overcomes the stability issue associated with high penetration of FRLs. The simulation results illustrate the effectiveness of the developed hierarchical control framework for providing primary frequency response with the proposed FRL controller.« less

  3. System Detects Vibrational Instabilities

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1990-01-01

    Sustained vibrations at two critical frequencies trigger diagnostic response or shutdown. Vibration-analyzing electronic system detects instabilities of combustion in rocket engine. Controls pulse-mode firing of engine and identifies vibrations above threshold amplitude at 5.9 and/or 12kHz. Adapted to other detection and/or control schemes involving simultaneous real-time detection of signals above or below preset amplitudes at two or more specified frequencies. Potential applications include rotating machinery and encoders and decoders in security systems.

  4. Transcranial alternating current stimulation modulates auditory temporal resolution in elderly people.

    PubMed

    Baltus, Alina; Vosskuhl, Johannes; Boetzel, Cindy; Herrmann, Christoph Siegfried

    2018-05-13

    Recent research provides evidence for a functional role of brain oscillations for perception. For example, auditory temporal resolution seems to be linked to individual gamma frequency of auditory cortex. Individual gamma frequency not only correlates with performance in between-channel gap detection tasks but can be modulated via auditory transcranial alternating current stimulation. Modulation of individual gamma frequency is accompanied by an improvement in gap detection performance. Aging changes electrophysiological frequency components and sensory processing mechanisms. Therefore, we conducted a study to investigate the link between individual gamma frequency and gap detection performance in elderly people using auditory transcranial alternating current stimulation. In a within-subject design, twelve participants were electrically stimulated with two individualized transcranial alternating current stimulation frequencies: 3 Hz above their individual gamma frequency (experimental condition) and 4 Hz below their individual gamma frequency (control condition) while they were performing a between-channel gap detection task. As expected, individual gamma frequencies correlated significantly with gap detection performance at baseline and in the experimental condition, transcranial alternating current stimulation modulated gap detection performance. In the control condition, stimulation did not modulate gap detection performance. In addition, in elderly, the effect of transcranial alternating current stimulation on auditory temporal resolution seems to be dependent on endogenous frequencies in auditory cortex: elderlies with slower individual gamma frequencies and lower auditory temporal resolution profit from auditory transcranial alternating current stimulation and show increased gap detection performance during stimulation. Our results strongly suggest individualized transcranial alternating current stimulation protocols for successful modulation of performance. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Deep Learning-Based Data Forgery Detection in Automatic Generation Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fengli; Li, Qinghua

    Automatic Generation Control (AGC) is a key control system in the power grid. It is used to calculate the Area Control Error (ACE) based on frequency and tie-line power flow between balancing areas, and then adjust power generation to maintain the power system frequency in an acceptable range. However, attackers might inject malicious frequency or tie-line power flow measurements to mislead AGC to do false generation correction which will harm the power grid operation. Such attacks are hard to be detected since they do not violate physical power system models. In this work, we propose algorithms based on Neural Networkmore » and Fourier Transform to detect data forgery attacks in AGC. Different from the few previous work that rely on accurate load prediction to detect data forgery, our solution only uses the ACE data already available in existing AGC systems. In particular, our solution learns the normal patterns of ACE time series and detects abnormal patterns caused by artificial attacks. Evaluations on the real ACE dataset show that our methods have high detection accuracy.« less

  6. System and method for islanding detection and prevention in distributed generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhowmik, Shibashis; Mazhari, Iman; Parkhideh, Babak

    Various examples are directed to systems and methods for detecting an islanding condition at an inverter configured to couple a distributed generation system to an electrical grid network. A controller may determine a command frequency and a command frequency variation. The controller may determine that the command frequency variation indicates a potential islanding condition and send to the inverter an instruction to disconnect the distributed generation system from the electrical grid network. When the distributed generation system is disconnected from the electrical grid network, the controller may determine whether the grid network is valid.

  7. Portable receiver for radar detection

    DOEpatents

    Lopes, Christopher D.; Kotter, Dale K.

    2008-10-14

    Various embodiments are described relating to a portable antenna-equipped device for multi-band radar detection. The detection device includes a plurality of antennas on a flexible substrate, a detection-and-control circuit, an indicator and a power source. The antenna may include one or more planar lithographic antennas that may be fabricated on a thin-film substrate. Each antenna may be tuned to a different selection frequency or band. The antennas may include a bolometer for radar detection. Each antenna may include a frequency selective surface for tuning to the selection frequency.

  8. Bubble measuring instrument and method

    NASA Technical Reports Server (NTRS)

    Magari, Patrick J. (Inventor); Kline-Schoder, Robert (Inventor)

    2003-01-01

    Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

  9. Bubble Measuring Instrument and Method

    NASA Technical Reports Server (NTRS)

    Kline-Schoder, Robert (Inventor); Magari, Patrick J. (Inventor)

    2002-01-01

    Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

  10. Genetic diversity and frequency of bovine viral diarrhea virus (BVDV) detected in cattle in Turkey

    USDA-ARS?s Scientific Manuscript database

    Rapid detection and culling of persistently infected animals and efficacious vaccination are key factors to control bovine viral diarrhea virus (BVDV) infections in cattle. The aim of this study was to investigate frequency of detection of persistently infected cattle and examine the diversity of bo...

  11. Electrostatically tunable resonance frequency beam utilizing a stress-sensitive film

    DOEpatents

    Thundat, Thomas G.; Wachter, Eric A.; Davis, J. Kenneth

    2001-01-01

    Methods and apparatus for detecting particular frequencies of acoustic vibration utilize an electrostatically-tunable beam element having a stress-sensitive coating and means for providing electrostatic force to controllably deflect the beam element thereby changing its stiffness and its resonance frequency. It is then determined from the response of the electrostatically-tunable beam element to the acoustical vibration to which the beam is exposed whether or not a particular frequency or frequencies of acoustic vibration are detected.

  12. Magnetically tunable resonance frequency beam utilizing a stress-sensitive film

    DOEpatents

    Davis, J. Kenneth; Thundat, Thomas G.; Wachter, Eric A.

    2001-01-01

    Methods and apparatus for detecting particular frequencies of vibration utilize a magnetically-tunable beam element having a stress-sensitive coating and means for providing magnetic force to controllably deflect the beam element thereby changing its stiffness and its resonance frequency. It is then determined from the response of the magnetically-tunable beam element to the vibration to which the beam is exposed whether or not a particular frequency or frequencies of vibration are detected.

  13. Method for detecting gas turbine engine flashback

    DOEpatents

    Singh, Kapil Kumar; Varatharajan, Balachandar; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin Paul

    2012-09-04

    A method for monitoring and controlling a gas turbine, comprises predicting frequencies of combustion dynamics in a combustor using operating conditions of a gas turbine, receiving a signal from a sensor that is indicative of combustion dynamics in the combustor, and detecting a flashback if a frequency of the received signal does not correspond to the predicted frequencies.

  14. Piezoelectrically tunable resonance frequency beam utilizing a stress-sensitive film

    DOEpatents

    Thundat, Thomas G.; Wachter, Eric A.

    2002-01-01

    Methods and apparatus for detecting particular frequencies of acoustic vibration utilize a piezoelectrically-tunable beam element having a piezoelectric layer and a stress sensitive layer and means for providing an electrical potential across the piezoelectric layer to controllably change the beam's stiffness and thereby change its resonance frequency. It is then determined from the response of the piezoelectrically-tunable beam element to the acoustical vibration to which the beam element is exposed whether or not a particular frequency or frequencies of acoustic vibration are detected.

  15. Gear-box fault detection using time-frequency based methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Odgaard, Peter Fogh; Stoustrup, Jakob

    2015-01-01

    Gear-box fault monitoring and detection is important for optimization of power generation and availability of wind turbines. The current industrial approach is to use condition monitoring systems, which runs in parallel with the wind turbine control system, using expensive additional sensors. An alternative would be to use the existing measurements which are normally available for the wind turbine control system. The usage of these sensors instead would cut down the cost of the wind turbine by not using additional sensors. One of these available measurements is the generator speed, in which changes in the gear-box resonance frequency can be detected.more » Two different time-frequency based approaches are presented in this paper. One is a filter based approach and the other is based on a Karhunen-Loeve basis. Both of them detects the gear-box fault with an acceptable detection delay.« less

  16. Sonic resonator control and method for determining component concentration in multiple component molten liquids

    DOEpatents

    Shen, Sin-Yan

    1984-01-01

    This invention teaches a control to be used in smelting aluminum by the electrolysis breakdown of alumina (A1.sub.2 O.sub.3) in a molten electrolyte heated to approximately 950.degree.-1000.degree. C. The invention provides a sonic resonator and control that can accurately detect the resonant frequency of the resonator in the molten electrolyte. The resonator preferably is made with tubular side wall 1/4 of the sonic wavelength, or is a quarter wave resonator. A wave generator inputs a signal having a range of frequencies that includes the resonant frequency, so that a peak resonant output at the resonant frequency can be detected on an oscilloscope or like detector. This instantaneous resonant frequency is then checked against an accurate data base correlating the resonant frequencies of the resonator in the electrolyte at specific alumina concentrations normally experienced throughout the electrolysis cycle. The electrolysis cycle can thus be controlled and recharged at any predetermined low alumina concentration greater than where the anode effect phase of the cycle normally might begin.

  17. Evaluation of selective control information detection scheme in orthogonal frequency division multiplexing-based radio-over-fiber and visible light communication links

    NASA Astrophysics Data System (ADS)

    Dalarmelina, Carlos A.; Adegbite, Saheed A.; Pereira, Esequiel da V.; Nunes, Reginaldo B.; Rocha, Helder R. O.; Segatto, Marcelo E. V.; Silva, Jair A. L.

    2017-05-01

    Block-level detection is required to decode what may be classified as selective control information (SCI) such as control format indicator in 4G-long-term evolution systems. Using optical orthogonal frequency division multiplexing over radio-over-fiber (RoF) links, we report the experimental evaluation of an SCI detection scheme based on a time-domain correlation (TDC) technique in comparison with the conventional maximum likelihood (ML) approach. When compared with the ML method, it is shown that the TDC method improves detection performance over both 20 and 40 km of standard single mode fiber (SSMF) links. We also report a performance analysis of the TDC scheme in noisy visible light communication channel models after propagation through 40 km of SSMF. Experimental and simulation results confirm that the TDC method is attractive for practical orthogonal frequency division multiplexing-based RoF and fiber-wireless systems. Unlike the ML method, another key benefit of the TDC is that it requires no channel estimation.

  18. Detection Performance Evaluation of the ASDE-3 Using Fixed Frequency and Frequency-Agile Operation

    DOT National Transportation Integrated Search

    1981-03-01

    The ASDE-3 (Airport Surface Detection Equipment) Radar design has many features to enhance operational usefulness. The purpose of all these features is to provide a better airport surface surveillance display for the control power tower cab. One of t...

  19. Tunable multiwalled nanotube resonator

    DOEpatents

    Jensen, Kenneth J; Girit, Caglar O; Mickelson, William E; Zettl, Alexander K; Grossman, Jeffrey C

    2013-11-05

    A tunable nanoscale resonator has potential applications in precise mass, force, position, and frequency measurement. One embodiment of this device consists of a specially prepared multiwalled carbon nanotube (MWNT) suspended between a metal electrode and a mobile, piezoelectrically controlled contact. By harnessing a unique telescoping ability of MWNTs, one may controllably slide an inner nanotube core from its outer nanotube casing, effectively changing its length and thereby changing the tuning of its resonance frequency. Resonant energy transfer may be used with a nanoresonator to detect molecules at a specific target oscillation frequency, without the use of a chemical label, to provide label-free chemical species detection.

  20. Tunable multiwalled nanotube resonator

    DOEpatents

    Zettl, Alex K [Kensington, CA; Jensen, Kenneth J [Berkeley, CA; Girit, Caglar [Albany, CA; Mickelson, William E [San Francisco, CA; Grossman, Jeffrey C [Berkeley, CA

    2011-03-29

    A tunable nanoscale resonator has potential applications in precise mass, force, position, and frequency measurement. One embodiment of this device consists of a specially prepared multiwalled carbon nanotube (MWNT) suspended between a metal electrode and a mobile, piezoelectrically controlled contact. By harnessing a unique telescoping ability of MWNTs, one may controllably slide an inner nanotube core from its outer nanotube casing, effectively changing its length and thereby changing the tuning of its resonance frequency. Resonant energy transfer may be used with a nanoresonator to detect molecules at a specific target oscillation frequency, without the use of a chemical label, to provide label-free chemical species detection.

  1. Benefit from NASA

    NASA Image and Video Library

    2004-04-15

    Technology derived by NASA for monitoring control gyros in the Skylab program is directly applicable to the problems of fault detection of railroad wheel bearings. Marhsall Space Flight Center's scientists have developed a detection concept based on the fact that bearing defects excite resonant frequency of rolling elements of the bearing as they impact the defect. By detecting resonant frequency and subsequently analyzing the character of this signal, bearing defects may be detected and identified as to source.

  2. Controller for controlling operation of at least one electrical load operating on an AC supply, and a method thereof

    DOEpatents

    Cantin, Luc; Deschenes, Mario; D'Amours, Mario

    1995-08-15

    A controller is provided for controlling operation of at least one electrical load operating on an AC supply having a typical frequency, the AC supply being provided via power transformers by an electrical power distribution grid. The controller is associated with the load and comprises an input interface for coupling the controller to the grid, a frequency detector for detecting the frequency of the AC supply and producing a signal indicative of the frequency, memory modules for storing preprogrammed commands, a frequency monitor for reading the signal indicative of the frequency and producing frequency data derived thereof, a selector for selecting at least one of the preprogrammed commands with respect to the frequency data, a control unit for producing at least one command signal representative of the selected preprogrammed commands, and an output interface including a device responsive to the command signal for controlling the load. Therefore, the load can be controlled by means of the controller depending on the frequency of the AC supply.

  3. Impacts of Inverter-Based Advanced Grid Support Functions on Islanding Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Austin; Hoke, Anderson; Miller, Brian

    A long-standing requirement for inverters paired with distributed energy resources is that they are required to disconnect from the electrical power system (EPS) when an electrical island is formed. In recent years, advanced grid support controls have been developed for inverters to provide voltage and frequency support by integrating functions such as voltage and frequency ride-through, volt-VAr control, and frequency-Watt control. With these new capabilities integrated into the inverter, additional examination is needed to determine how voltage and frequency support will impact pre-existing inverter functions like island detection. This paper inspects how advanced inverter functions will impact its ability tomore » detect the formation of an electrical island. Results are presented for the unintentional islanding laboratory tests of three common residential-scale photovoltaic inverters performing various combinations of grid support functions. For the inverters tested, grid support functions prolonged island disconnection times slightly; however, it was found that in all scenarios the inverters disconnected well within two seconds, the limit imposed by IEEE Std 1547-2003.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Stephen F; Moore, James A

    Systems and methods are described for carrier phase synchronization for improved AM and TV broadcast reception. A method includes synchronizing the phase of a carrier frequency of a broadcast signal with the phase of a remote reference frequency. An apparatus includes a receiver to detect the phase of a reference signal; a phase comparator coupled to the reference signal-phase receiver; a voltage controlled oscillator coupled to the phase comparator; and a phase-controlled radio frequency output coupled to the voltage controlled oscillator.

  5. An integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection

    NASA Astrophysics Data System (ADS)

    Liu, Hai-Tao; Wen, Zhi-Yu; Xu, Yi; Shang, Zheng-Guo; Peng, Jin-Lan; Tian, Peng

    2017-09-01

    In this paper, an integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection was purposed based on microfluidic chips dielectrophoresis technique and electrochemical impedance detection principle. The microsystems include microfluidic chip, main control module, and drive and control module, and signal detection and processing modulet and result display unit. The main control module produce the work sequence of impedance detection system parts and achieve data communication functions, the drive and control circuit generate AC signal which amplitude and frequency adjustable, and it was applied on the foodborne pathogens impedance analysis microsystems to realize the capture enrichment and impedance detection. The signal detection and processing circuit translate the current signal into impendence of bacteria, and transfer to computer, the last detection result is displayed on the computer. The experiment sample was prepared by adding Escherichia coli standard sample into chicken sample solution, and the samples were tested on the dielectrophoresis chip capture enrichment and in-situ impedance detection microsystems with micro-array electrode microfluidic chips. The experiments show that the Escherichia coli detection limit of microsystems is 5 × 104 CFU/mL and the detection time is within 6 min in the optimization of voltage detection 10 V and detection frequency 500 KHz operating conditions. The integrated microfluidic analysis microsystems laid the solid foundation for rapid real-time in-situ detection of bacteria.

  6. On-Line Loss of Control Detection Using Wavelets

    NASA Technical Reports Server (NTRS)

    Brenner, Martin J. (Technical Monitor); Thompson, Peter M.; Klyde, David H.; Bachelder, Edward N.; Rosenthal, Theodore J.

    2005-01-01

    Wavelet transforms are used for on-line detection of aircraft loss of control. Wavelet transforms are compared with Fourier transform methods and shown to more rapidly detect changes in the vehicle dynamics. This faster response is due to a time window that decreases in length as the frequency increases. New wavelets are defined that further decrease the detection time by skewing the shape of the envelope. The wavelets are used for power spectrum and transfer function estimation. Smoothing is used to tradeoff the variance of the estimate with detection time. Wavelets are also used as front-end to the eigensystem reconstruction algorithm. Stability metrics are estimated from the frequency response and models, and it is these metrics that are used for loss of control detection. A Matlab toolbox was developed for post-processing simulation and flight data using the wavelet analysis methods. A subset of these methods was implemented in real time and named the Loss of Control Analysis Tool Set or LOCATS. A manual control experiment was conducted using a hardware-in-the-loop simulator for a large transport aircraft, in which the real time performance of LOCATS was demonstrated. The next step is to use these wavelet analysis tools for flight test support.

  7. Detection of changes of high-frequency activity by statistical time-frequency analysis in epileptic spikes

    PubMed Central

    Kobayashi, Katsuhiro; Jacobs, Julia; Gotman, Jean

    2013-01-01

    Objective A novel type of statistical time-frequency analysis was developed to elucidate changes of high-frequency EEG activity associated with epileptic spikes. Methods The method uses the Gabor Transform and detects changes of power in comparison to background activity using t-statistics that are controlled by the false discovery rate (FDR) to correct type I error of multiple testing. The analysis was applied to EEGs recorded at 2000 Hz from three patients with mesial temporal lobe epilepsy. Results Spike-related increase of high-frequency oscillations (HFOs) was clearly shown in the FDR-controlled t-spectra: it was most dramatic in spikes recorded from the hippocampus when the hippocampus was the seizure onset zone (SOZ). Depression of fast activity was observed immediately after the spikes, especially consistently in the discharges from the hippocampal SOZ. It corresponded to the slow wave part in case of spike-and-slow-wave complexes, but it was noted even in spikes without apparent slow waves. In one patient, a gradual increase of power above 200 Hz preceded spikes. Conclusions FDR-controlled t-spectra clearly detected the spike-related changes of HFOs that were unclear in standard power spectra. Significance We developed a promising tool to study the HFOs that may be closely linked to the pathophysiology of epileptogenesis. PMID:19394892

  8. Laser frequency-offset locking based on the frequency modulation spectroscopy with higher harmonic detection

    NASA Astrophysics Data System (ADS)

    Wang, Anqi; Meng, Zhixin; Feng, Yanying

    2017-10-01

    We design a fiber electro-optic modulator (FEOM)-based laser frequency-offset locking system using frequency modulation spectroscopy (FMS) with the 3F modulation. The modulation signal and the frequency-offset control signal are simultaneously loaded on the FEOM by a mixer in order to suppress the frequency and power jitter caused by internal modulation on the current or piezoelectric ceramic transducer (PZT). It is expected to accomplish a fast locking, a widely tunable frequency-offset, a sensitive and rapid detection of narrow spectral features with the 3F modulation. The laser frequency fluctuation is limited to +/-1MHz and its overlapping Allan deviation is around 10-12 in twenty minutes, which successfully meets the requirements of the cold atom interferometer.

  9. Multiple sound source localization using gammatone auditory filtering and direct sound componence detection

    NASA Astrophysics Data System (ADS)

    Chen, Huaiyu; Cao, Li

    2017-06-01

    In order to research multiple sound source localization with room reverberation and background noise, we analyze the shortcomings of traditional broadband MUSIC and ordinary auditory filtering based broadband MUSIC method, then a new broadband MUSIC algorithm with gammatone auditory filtering of frequency component selection control and detection of ascending segment of direct sound componence is proposed. The proposed algorithm controls frequency component within the interested frequency band in multichannel bandpass filter stage. Detecting the direct sound componence of the sound source for suppressing room reverberation interference is also proposed, whose merits are fast calculation and avoiding using more complex de-reverberation processing algorithm. Besides, the pseudo-spectrum of different frequency channels is weighted by their maximum amplitude for every speech frame. Through the simulation and real room reverberation environment experiments, the proposed method has good performance. Dynamic multiple sound source localization experimental results indicate that the average absolute error of azimuth estimated by the proposed algorithm is less and the histogram result has higher angle resolution.

  10. Stimulus Disparity and Punisher Control of Human Signal-Detection Performance

    ERIC Educational Resources Information Center

    Lie, Celia; Alsop, Brent

    2010-01-01

    The present experiment examined the effects of varying stimulus disparity and relative punisher frequencies on signal detection by humans. Participants were placed into one of two groups. Group 3 participants were presented with 1:3 and 3:1 punisher frequency ratios, while Group 11 participants were presented with 1:11 and 11:1 punisher frequency…

  11. Carrier phase synchronization system for improved amplitude modulation and television broadcast reception

    DOEpatents

    Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN

    2011-02-01

    Systems and methods are described for carrier phase synchronization for improved AM and TV broadcast reception. A method includes synchronizing the phase of a carrier frequency of a broadcast signal with the phase of a remote reference frequency. An apparatus includes a receiver to detect the phase of a reference signal; a phase comparator coupled to the reference signal-phase receiver; a voltage controlled oscillator coupled to the phase comparator; and a phase-controlled radio frequency output coupled to the voltage controlled oscillator.

  12. A prevalence-based association test for case-control studies.

    PubMed

    Ryckman, Kelli K; Jiang, Lan; Li, Chun; Bartlett, Jacquelaine; Haines, Jonathan L; Williams, Scott M

    2008-11-01

    Genetic association is often determined in case-control studies by the differential distribution of alleles or genotypes. Recent work has demonstrated that association can also be assessed by deviations from the expected distributions of alleles or genotypes. Specifically, multiple methods motivated by the principles of Hardy-Weinberg equilibrium (HWE) have been developed. However, these methods do not take into account many of the assumptions of HWE. Therefore, we have developed a prevalence-based association test (PRAT) as an alternative method for detecting association in case-control studies. This method, also motivated by the principles of HWE, uses an estimated population allele frequency to generate expected genotype frequencies instead of using the case and control frequencies separately. Our method often has greater power, under a wide variety of genetic models, to detect association than genotypic, allelic or Cochran-Armitage trend association tests. Therefore, we propose PRAT as a powerful alternative method of testing for association.

  13. [Effects of extremely low frequency electromagnetic radiation on cardiovascular system of workers].

    PubMed

    Zhao, Long-yu; Song, Chun-xiao; Yu, Duo; Liu, Xiao-liang; Guo, Jian-qiu; Wang, Chuan; Ding, Yuan-wei; Zhou, Hong-xia; Ma, Shu-mei; Liu, Xiao-dong; Liu, Xin

    2012-03-01

    To observe the exposure levels of extremely low frequency electromagnetic fields in workplaces and to analyze the effects of extremely low frequency electromagnetic radiation on cardiovascular system of occupationally exposed people. Intensity of electromagnetic fields in two workplaces (control and exposure groups) was detected with EFA-300 frequency electromagnetic field strength tester, and intensity of the noise was detected with AWA5610D integral sound level. The information of health physical indicators of 188 controls and 642 occupationally exposed workers was collected. Data were analyzed by SPSS17.0 statistic software. The intensity of electric fields and the magnetic fields in exposure groups was significantly higher than that in control group (P < 0.05), but there was no significant difference of noise between two workplaces (P > 0.05). The results of physical examination showed that the abnormal rates of HCY, ALT, AST, GGT, ECG in the exposure group were significantly higher than those in control group (P < 0.05). There were no differences of sex, age, height, weight between two groups (P > 0.05). Exposure to extremely low frequency electromagnetic radiation may have some effects on the cardiovascular system of workers.

  14. Vibration detection of component health and operability

    NASA Technical Reports Server (NTRS)

    Baird, B. C.

    1975-01-01

    In order to prevent catastrophic failure and eliminate unnecessary periodic maintenance in the shuttle orbiter program environmental control system components, some means of detecting incipient failure in these components is required. The utilization was investigated of vibrational/acoustic phenomena as one of the principal physical parameters on which to base the design of this instrumentation. Baseline vibration/acoustic data was collected from three aircraft type fans and two aircraft type pumps over a frequency range from a few hertz to greater than 3000 kHz. The baseline data included spectrum analysis of the baseband vibration signal, spectrum analysis of the detected high frequency bandpass acoustic signal, and amplitude distribution of the high frequency bandpass acoustic signal. A total of eight bearing defects and two unbalancings was introduced into the five test items. All defects were detected by at least one of a set of vibration/acoustic parameters with a margin of at least 2:1 over the worst case baseline. The design of a portable instrument using this set of vibration/acoustic parameters for detecting incipient failures in environmental control system components is described.

  15. Wavelet-frequency analysis for the detection of discontinuities in switched system models of human balance.

    PubMed

    Nema, Salam; Kowalczyk, Piotr; Loram, Ian

    2017-01-01

    This paper is concerned with detecting the presence of switching behavior in experimentally obtained posturographic data sets by means of a novel algorithm that is based on a combination of wavelet analysis and Hilbert transform. As a test-bed for the algorithm, we first use a switched model of human balance control during quiet standing with known switching behavior in four distinct configurations. We obtain a time-frequency representation of a signal generated by our model system. We are then able to detect manifestations of discontinuities (switchings) in the signal as spiking behavior. The frequency of switchings, measured by means of our algorithm and detected in our models systems, agrees with the frequency of spiking behavior found in the experimentally obtained posturographic data. Copyright © 2016. Published by Elsevier B.V.

  16. Detection frequency of human herpesviruses-6A, -6B, and -7 genomic sequences in central nervous system DNA samples from post-mortem individuals with unspecified encephalopathy.

    PubMed

    Chapenko, Svetlana; Roga, Silvija; Skuja, Sandra; Rasa, Santa; Cistjakovs, Maksims; Svirskis, Simons; Zaserska, Zane; Groma, Valerija; Murovska, Modra

    2016-08-01

    In this autopsy-based study, human herpesvirus-6 (HHV-6) and -7 (HHV-7) genomic sequence frequency, HHV-6 variants, HHV-6 load and the expression of HHV-6 antigens in brain samples from the individuals, with and without unspecified encephalopathy (controls), using nested and real-time polymerase chain reactions, restriction endonuclease, and immunohistochemical analysis were examined. GraphPad Prism 6.0 Mann-Whitney nonparametric and chi-square test and Fisher's exact test were used for statistical analysis. The encephalopathy diagnoses were shown by magnetic resonance imaging made during their lifetime and macro- and microscopically studied autopsy tissue materials. Widespread HHV-6 and/or HHV-7 positivity was detected in the brain tissue of various individuals with encephalopathy, as well as in controls (51/57, 89.4 % and 35/51, 68.6 %, respectively; p = 0.009). Significantly higher detection frequency of single HHV-6 and concurrent HHV-6 + HHV-7 DNA was found in pia mater meninges, frontal lobe, temporal lobe, and olfactory tract DNAs in individuals with encephalopathy compared to the control group. HHV-6 load and higher frequency of the viral load >10 copies/10(6) cells significantly differed in samples from individuals with and without encephalopathy. The expression of HHV-6 antigens was revealed in different neural cell types with strong predominance in the encephalopathy group. In all HHV-6-positive autopsy samples of individuals with and without encephalopathy, HHV-6B was revealed. Significantly higher detection frequency of beta-herpesvirus DNA, more often detected HHV-6 load >10 copies/10(6) cells, as well as the expression of HHV-6 antigens in different brain tissue samples from individuals with encephalopathy in comparison with control group indicate on potential involvement of these viruses in encephalopathy development.

  17. The role of modern control theory in the design of controls for aircraft turbine engines

    NASA Technical Reports Server (NTRS)

    Zeller, J.; Lehtinen, B.; Merrill, W.

    1982-01-01

    The development, applications, and current research in modern control theory (MCT) are reviewed, noting the importance for fuel-efficient operation of turbines with variable inlet guide vanes, compressor stators, and exhaust nozzle area. The evolution of multivariable propulsion control design is examined, noting a basis in a matrix formulation of the differential equations defining the process, leading to state space formulations. Reports and papers which appeared from 1970-1982 which dealt with problems in MCT applications to turbine engine control design are outlined, including works on linear quadratic regulator methods, frequency domain methods, identification, estimation, and model reduction, detection, isolation, and accommodation, and state space control, adaptive control, and optimization approaches. Finally, NASA programs in frequency domain design, sensor failure detection, computer-aided control design, and plant modeling are explored

  18. Spectrophone stabilized laser with line center offset frequency control

    NASA Technical Reports Server (NTRS)

    Kavaya, M. J.; Menzies, R. T. (Inventor)

    1984-01-01

    Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

  19. [Human Papilloma virus in Quechua women from Jujuy with high frequency of cervical cancer: viral types and HPV-16 variants].

    PubMed

    Picconi, Maria Alejandra; Gronda, Jorge; Alonio, Lidia V; Villa, Luisa L; Sichero, Laura; Miranda, Sergio; Barcena, Martin; Teyssie, Angelica

    2002-01-01

    Human Papillomaviruses (HPVs) are etiologically associated to cervical carcinoma. In order to evaluate HPV infection and its relationship with the high frequency of this neoplasia in Quechua women from Jujuy (Argentina), 271 cervical samples from preneoplastic and neoplastic lesions (biopsies) and normal controls (cytologies) were studied. Detection and typing were performed using PCR-RFLP or PCR-hybridization and the HPV-16 variability in L1 and E6 genes (by PCR-hybridization) was analysed. HPV was detected in 52% of controls, 91% of low-grade lesions, 97% of high-grade lesions and 100% of invasive carcinomas, corresponding 55% to HPV-16. HPV-16 European variants were predominant, most of them being non-prototypic strains. The high frequency of high risk infection types and the raised proportion of HPV-16 non-prototypic variants related to a greater oncogenic potential could explain, in part, the high cervical cancer frequency of this native population. These data may contribute to disease control and vaccinal formulation.

  20. Methodological demonstration of laser beam pointing control for space gravitational wave detection missions.

    PubMed

    Dong, Yu-Hui; Liu, He-Shan; Luo, Zi-Ren; Li, Yu-Qiong; Jin, Gang

    2014-07-01

    In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.

  1. Methodological demonstration of laser beam pointing control for space gravitational wave detection missions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Yu-Hui; Liu, He-Shan; University of Chinese Academy of Sciences, Beijing 100190

    In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differentialmore » Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.« less

  2. Automated surface-scanning detection of pathogenic bacteria on fresh produce

    NASA Astrophysics Data System (ADS)

    Horikawa, Shin; Du, Songtao; Liu, Yuzhe; Chen, I.-Hsuan; Xi, Jianguo; Crumpler, Michael S.; Sirois, Donald L.; Best, Steve R.; Wikle, Howard C.; Chin, Bryan A.

    2017-05-01

    This paper investigates the effects of surface-scanning detector position on the resonant frequency and signal amplitude of a wireless magnetoelastic (ME) biosensor for direct pathogen detection on solid surfaces. The experiments were conducted on the surface of a flat polyethylene (PE) plate as a model study. An ME biosensor (1 mm × 0.2 mm × 30 μm) was placed on the PE surface, and a surface-scanning detector was brought close and aligned to the sensor for wireless resonant frequency measurement. The position of the detector was accurately controlled by using a motorized three-axis translation system (i.e., controlled X, Y, and Z positions). The results showed that the resonant frequency variations of the sensor were -125 to +150 Hz for X and Y detector displacements of +/-600 μm and Z displacements of +100 to +500 μm. These resonant frequency variations were small compared to the sensor's initial resonant frequency (< 0.007% of 2.2 MHz initial resonant frequency) measured at the detector home position, indicating high accuracy of the measurement. In addition, the signal amplitude was, as anticipated, found to decrease exponentially with increasing detection distance (i.e., Z distance). Finally, additional experiments were conducted on the surface of cucumbers. Similar results were obtained.

  3. Variable frequency microwave furnace system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bible, D.W.; Lauf, R.J.

    1994-06-14

    A variable frequency microwave furnace system designed to allow modulation of the frequency of the microwaves introduced into a furnace cavity for testing or other selected applications. The variable frequency microwave furnace system includes a microwave signal generator or microwave voltage-controlled oscillator for generating a low-power microwave signal for input to the microwave furnace. A first amplifier may be provided to amplify the magnitude of the signal output from the microwave signal generator or the microwave voltage-controlled oscillator. A second amplifier is provided for processing the signal output by the first amplifier. The second amplifier outputs the microwave signal inputmore » to the furnace cavity. In the preferred embodiment, the second amplifier is a traveling-wave tube (TWT). A power supply is provided for operation of the second amplifier. A directional coupler is provided for detecting the direction of a signal and further directing the signal depending on the detected direction. A first power meter is provided for measuring the power delivered to the microwave furnace. A second power meter detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load. 5 figs.« less

  4. Variable frequency microwave furnace system

    DOEpatents

    Bible, D.W.; Lauf, R.J.

    1994-06-14

    A variable frequency microwave furnace system designed to allow modulation of the frequency of the microwaves introduced into a furnace cavity for testing or other selected applications. The variable frequency microwave furnace system includes a microwave signal generator or microwave voltage-controlled oscillator for generating a low-power microwave signal for input to the microwave furnace. A first amplifier may be provided to amplify the magnitude of the signal output from the microwave signal generator or the microwave voltage-controlled oscillator. A second amplifier is provided for processing the signal output by the first amplifier. The second amplifier outputs the microwave signal input to the furnace cavity. In the preferred embodiment, the second amplifier is a traveling-wave tube (TWT). A power supply is provided for operation of the second amplifier. A directional coupler is provided for detecting the direction of a signal and further directing the signal depending on the detected direction. A first power meter is provided for measuring the power delivered to the microwave furnace. A second power meter detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load. 5 figs.

  5. Frequency of Atrial Septal Aneurysms in Patients with Cerebral Ischemic Events

    NASA Technical Reports Server (NTRS)

    Agmon, Yoram; Khandheria, Bijoy K.; Meissner, Irene; Gentile, Federico; Whisnant, Jack P.; Sicks, JoRean D.; O'Fallon, W. Michael; Covalt, Jody L.; Wiebers, David O.; Seward, James B.

    1999-01-01

    Background-Atrial septal aneurysm (ASA) is a putative risk factor for cardioembolism. However, the frequency of ASA in the general population has not been adequately determined. Therefore, the frequency in patients with cerebral ischemic events, compared with the frequency in the general population, is poorly defined. We sought to determine the frequency of ASA in the general population and to compare the frequency of ASA in patients with cerebral ischemic events with the frequency in the general population. Methods and Results-The frequency of ASA in the population was determined in 363 subjects, a sample of the participants in the Stroke Prevention: Assessment of Risk in a Community study (control subjects), and was compared with the frequency in 355 age- and sex-matched patients undergoing transesophageal echocardiography in search of a cardiac source of embolism after a focal cerebral ischemic event. The proportion with ASA was 7.9% in patients versus 2.2% in control subjects (P=0.002; odds ratio of ASA, 3.65; 95% CI, 1.64 to 8.13, in patients versus control subjects). Patent foramen ovale (PFO) was detected with contrast injections in 56% of subjects with ASA. The presence of ASA predicted the presence of PFO (odds ratio of PFO, 4.57; 95% CI, 2.18 to 9.57, in subjects with versus those without ASA). In 86% of subjects with ASA and cerebral ischemia, transesophageal echocardiography did not detect an alternative source of cardioembolism other than an associated PFO. Conclusions-The prevalence of ASA based on this population-based study is 2.2%. The frequency of ASA is relatively higher in patients evaluated with transesophageal echocardiography after a cerebral ischemic event. ASA is frequently associated with PFO, suggesting paradoxical embolism as a mechanism of cardioembolism. In patients with cerebral ischemia and ASA, ASA (with or without PFO) commonly is the only potential cardioembolic source detected with transesophageal echocardiography.

  6. Effects of visual erotic stimulation on vibrotactile detection thresholds in men.

    PubMed

    Jiao, Chuanshu; Knight, Peter K; Weerakoon, Patricia; Turman, A Bulent

    2007-12-01

    This study examined the effects of sexual arousal on vibration detection thresholds in the right index finger of 30 healthy, heterosexual males who reported no sexual dysfunction. Vibrotactile detection thresholds at frequencies of 30, 60, and 100 Hz were assessed before and after watching erotic and control videos using a forced-choice, staircase method. A mechanical stimulator was used to produce the vibratory stimulus. Results were analyzed using repeated measures analysis of variance. After watching the erotic video, the vibrotactile detection thresholds at 30, 60, and 100 Hz were significantly reduced (p < .01). No changes in thresholds were detected at any frequency following exposure to the non-erotic stimulus. The results show that sexual arousal resulted in an increase in vibrotactile sensitivity to low frequency stimuli in the index finger of sexually functional men.

  7. Self-Tuning Adaptive-Controller Using Online Frequency Identification

    NASA Technical Reports Server (NTRS)

    Chiang, W. W.; Cannon, R. H., Jr.

    1985-01-01

    A real time adaptive controller was designed and tested successfully on a fourth order laboratory dynamic system which features very low structural damping and a noncolocated actuator sensor pair. The controller, implemented in a digital minicomputer, consists of a state estimator, a set of state feedback gains, and a frequency locked loop (FLL) for real time parameter identification. The FLL can detect the closed loop natural frequency of the system being controlled, calculate the mismatch between a plant parameter and its counterpart in the state estimator, and correct the estimator parameter in real time. The adaptation algorithm can correct the controller error and stabilize the system for more than 50% variation in the plant natural frequency, compared with a 10% stability margin in frequency variation for a fixed gain controller having the same performance at the nominal plant condition. After it has locked to the correct plant frequency, the adaptive controller works as well as the fixed gain controller does when there is no parameter mismatch. The very rapid convergence of this adaptive system is demonstrated experimentally, and can also be proven with simple root locus methods.

  8. Signal injection as a fault detection technique.

    PubMed

    Cusidó, Jordi; Romeral, Luis; Ortega, Juan Antonio; Garcia, Antoni; Riba, Jordi

    2011-01-01

    Double frequency tests are used for evaluating stator windings and analyzing the temperature. Likewise, signal injection on induction machines is used on sensorless motor control fields to find out the rotor position. Motor Current Signature Analysis (MCSA), which focuses on the spectral analysis of stator current, is the most widely used method for identifying faults in induction motors. Motor faults such as broken rotor bars, bearing damage and eccentricity of the rotor axis can be detected. However, the method presents some problems at low speed and low torque, mainly due to the proximity between the frequencies to be detected and the small amplitude of the resulting harmonics. This paper proposes the injection of an additional voltage into the machine being tested at a frequency different from the fundamental one, and then studying the resulting harmonics around the new frequencies appearing due to the composition between injected and main frequencies.

  9. Signal Injection as a Fault Detection Technique

    PubMed Central

    Cusidó, Jordi; Romeral, Luis; Ortega, Juan Antonio; Garcia, Antoni; Riba, Jordi

    2011-01-01

    Double frequency tests are used for evaluating stator windings and analyzing the temperature. Likewise, signal injection on induction machines is used on sensorless motor control fields to find out the rotor position. Motor Current Signature Analysis (MCSA), which focuses on the spectral analysis of stator current, is the most widely used method for identifying faults in induction motors. Motor faults such as broken rotor bars, bearing damage and eccentricity of the rotor axis can be detected. However, the method presents some problems at low speed and low torque, mainly due to the proximity between the frequencies to be detected and the small amplitude of the resulting harmonics. This paper proposes the injection of an additional voltage into the machine being tested at a frequency different from the fundamental one, and then studying the resulting harmonics around the new frequencies appearing due to the composition between injected and main frequencies. PMID:22163801

  10. Climate, orography and scale controls on flood frequency in Triveneto (Italy)

    NASA Astrophysics Data System (ADS)

    Persiano, Simone; Castellarin, Attilio; Salinas, Jose Luis; Domeneghetti, Alessio; Brath, Armando

    2016-05-01

    The growing concern about the possible effects of climate change on flood frequency regime is leading Authorities to review previously proposed reference procedures for design-flood estimation, such as national flood frequency models. Our study focuses on Triveneto, a broad geographical region in North-eastern Italy. A reference procedure for design flood estimation in Triveneto is available from the Italian NCR research project "VA.PI.", which considered Triveneto as a single homogeneous region and developed a regional model using annual maximum series (AMS) of peak discharges that were collected up to the 1980s by the former Italian Hydrometeorological Service. We consider a very detailed AMS database that we recently compiled for 76 catchments located in Triveneto. All 76 study catchments are characterized in terms of several geomorphologic and climatic descriptors. The objective of our study is threefold: (1) to inspect climatic and scale controls on flood frequency regime; (2) to verify the possible presence of changes in flood frequency regime by looking at changes in time of regional L-moments of annual maximum floods; (3) to develop an updated reference procedure for design flood estimation in Triveneto by using a focused-pooling approach (i.e. Region of Influence, RoI). Our study leads to the following conclusions: (1) climatic and scale controls on flood frequency regime in Triveneto are similar to the controls that were recently found in Europe; (2) a single year characterized by extreme floods can have a remarkable influence on regional flood frequency models and analyses for detecting possible changes in flood frequency regime; (3) no significant change was detected in the flood frequency regime, yet an update of the existing reference procedure for design flood estimation is highly recommended and we propose the RoI approach for properly representing climate and scale controls on flood frequency in Triveneto, which cannot be regarded as a single homogeneous region.

  11. Active stabilization of a rapidly chirped laser by an optoelectronic digital servo-loop control.

    PubMed

    Gorju, G; Jucha, A; Jain, A; Crozatier, V; Lorgeré, I; Le Gouët, J-L; Bretenaker, F; Colice, M

    2007-03-01

    We propose and demonstrate a novel active stabilization scheme for wide and fast frequency chirps. The system measures the laser instantaneous frequency deviation from a perfectly linear chirp, thanks to a digital phase detection process, and provides an error signal that is used to servo-loop control the chirped laser. This way, the frequency errors affecting a laser scan over 10 GHz on the millisecond timescale are drastically reduced below 100 kHz. This active optoelectronic digital servo-loop control opens new and interesting perspectives in fields where rapidly chirped lasers are crucial.

  12. Monitoring controlled graves representing common burial scenarios with ground penetrating radar

    NASA Astrophysics Data System (ADS)

    Schultz, John J.; Martin, Michael M.

    2012-08-01

    Implementing controlled geophysical research is imperative to understand the variables affecting detection of clandestine graves during real-life forensic searches. This study focused on monitoring two empty control graves (shallow and deep) and six burials containing a small pig carcass (Sus scrofa) representing different burial forensic scenarios: a shallow buried naked carcass, a deep buried naked carcass, a deep buried carcass covered by a layer of rocks, a deep buried carcass covered by a layer of lime, a deep buried carcass wrapped in an impermeable tarpaulin and a deep buried carcass wrapped in a cotton blanket. Multi-frequency, ground penetrating radar (GPR) data were collected monthly over a 12-month monitoring period. The research site was a cleared field within a wooded area in a humid subtropical environment, and the soil consisted of a Spodosol, a common soil type in Florida. This study compared 2D GPR reflection profiles and horizontal time slices obtained with both 250 and 500 MHz dominant frequency antennae to determine the utility of both antennae for grave detection in this environment over time. Overall, a combination of both antennae frequencies provided optimal detection of the targets. Better images were noted for deep graves, compared to shallow graves. The 250 MHz antenna provided better images for detecting deep graves, as less non-target anomalies were produced with lower radar frequencies. The 250 MHz antenna also provided better images detecting the disturbed ground. Conversely, the 500 MHz antenna provided better images when detecting the shallow pig grave. The graves that contained a pig carcass with associated grave items provided the best results, particularly the carcass covered with rocks and the carcass wrapped in a tarpaulin. Finally, during periods of increased soil moisture levels, there was increased detection of graves that was most likely related to conductive decompositional fluid from the carcasses.

  13. Improved Controller Design of Grid Friendly™ Appliances for Primary Frequency Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, Jianming; Sun, Yannan; Marinovici, Laurentiu D.

    2015-09-01

    The Grid Friendlymore » $$^\\textrm{TM}$$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, can autonomously switch off the appliances by detecting the under-frequency events. In this paper, the impacts of curtailing frequency threshold on the performance of frequency responsive GFAs are carefully analyzed first. The current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In addition, the power reduction of online GFAs could be so excessive that it can even impact the system response negatively. As a remedy to the deficiency of the current controller design, a different way of selecting curtailing frequency thresholds is proposed to ensure the effectiveness of GFAs in frequency protection. Moreover, it is also proposed to introduce a supervisor at each distribution feeder to monitor the curtailing frequency thresholds of online GFAs and take corrective actions if necessary.« less

  14. Reactor control rod timing system. [LMFBR

    DOEpatents

    Wu, P.T.K.

    1980-03-18

    A fluid driven jet-edge whistle timing system is described for control rods of a nuclear reactor for producing real-time detection of the timing of each control rod in its scram operation. An important parameter in reactor safety, particularly for liquid metal fast breeder reactors (LMFBR), is the time deviation between the time the control rod is released and the time the rod actually reaches the down position. The whistle has a nearly pure tone signal with center frequency (above 100 kHz) far above the frequency band in which the energy of the background noise is concentrated. Each control rod can be fitted with a whistle with a different frequency so that there is no ambiguity in differentiating the signal from each control rod.

  15. Reactor control rod timing system

    DOEpatents

    Wu, Peter T. K.

    1982-01-01

    A fluid driven jet-edge whistle timing system for control rods of a nuclear reactor for producing real-time detection of the timing of each control rod in its scram operation. An important parameter in reactor safety, particularly for liquid metal fast breeder reactors (LMFBR), is the time deviation between the time the control rod is released and the time the rod actually reaches the down position. The whistle has a nearly pure tone signal with center frequency (above 100 kHz) far above the frequency band in which the energy of the background noise is concentrated. Each control rod can be fitted with a whistle with a different frequency so that there is no ambiguity in differentiating the signal from each control rod.

  16. Optical superheterodyne receiver.

    PubMed

    Lucy, R F; Lang, K; Peters, C J; Duval, K

    1967-08-01

    Optical communications experiments at 6328 A, comparing the fading characteristics of coherent and noncoherent optical detection, have been performed over a 1-km real atmospheric path in different weather conditions. The results show that fading is less severe for noncoherent detection and that the fading characteristic for both types vary significantly with weather conditions. In addition, the similarity of optical FM to rf FM is demonstrated. The measurements were performed using a remote laser transmitter and an optical superheterodyne receiver operating simultaneously in both a coherent and noncoherent detection mode. The receiver, tunable over a frequency range of 1 GHz at the IF difference frequency of 30 MHz, has automatic frequency control and also uses a precision angle tracking servo to maintain receiver spatial alignment with a remote transmitter. The angle and frequency tracking capability permit operation between moving transmitter and receiver terminals.

  17. Application of statistical process control to qualitative molecular diagnostic assays.

    PubMed

    O'Brien, Cathal P; Finn, Stephen P

    2014-01-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  18. A versatile microprocessor-controlled hybrid receiver. [with firmware control for operation over large frequency uncertainty

    NASA Technical Reports Server (NTRS)

    Grant, T. L.

    1978-01-01

    A hybrid receiver has been designed for the Galileo Project. The receiver, located on the Galileo Orbiter, will autonomously acquire and track signals from the first atmospheric probe of Jupiter as well as demodulate, bit-synchronize, and buffer the telemetry data. The receiver has a conventional RF and LF front end but performs multiple functions digitally under firmware control. It will be a self-acquiring receiver that operates under a large frequency uncertainty; it can accommodate different modulation types, bit rates, and other parameter changes via reprogramming. A breadboard receiver and test set demonstrate a preliminary version of the sequential detection process and verify the hypothesis that a fading channel does not reduce the probability of detection.

  19. Direct detection of a transport-blocking trap in a nanoscaled silicon single-electron transistor by radio-frequency reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villis, B. J.; Sanquer, M.; Jehl, X.

    2014-06-09

    The continuous downscaling of transistors results in nanoscale devices which require fewer and fewer charged carriers for their operation. The ultimate charge controlled device, the single-electron transistor (SET), controls the transfer of individual electrons. It is also the most sensitive electrometer, and as a result the electron transport through it can be dramatically affected by nearby charges. Standard direct-current characterization techniques, however, are often unable to unambiguously detect and resolve the origin of the observed changes in SET behavior arising from changes in the charge state of a capacitively coupled trap. Using a radio-frequency (RF) reflectometry technique, we are ablemore » to unequivocally detect this process, in very close agreement with modeling of the trap's occupation probability.« less

  20. Harmonic Characteristics of Rectifier Substations and Their Impact on Audio Frequency Track Circuits

    DOT National Transportation Integrated Search

    1982-05-01

    This report describes the basic operation of substation rectifier equipment and the modes of possible interference with audio frequency track circuits used for train detection, cab signalling, and vehicle speed control. It also includes methods of es...

  1. Variable frequency microwave furnace system

    DOEpatents

    Bible, Don W.; Lauf, Robert J.

    1994-01-01

    A variable frequency microwave furnace system (10) designed to allow modulation of the frequency of the microwaves introduced into a furnace cavity (34) for testing or other selected applications. The variable frequency microwave furnace system (10) includes a microwave signal generator (12) or microwave voltage-controlled oscillator (14) for generating a low-power microwave signal for input to the microwave furnace. A first amplifier (18) may be provided to amplify the magnitude of the signal output from the microwave signal generator (12) or the microwave voltage-controlled oscillator (14). A second amplifier (20) is provided for processing the signal output by the first amplifier (18). The second amplifier (20) outputs the microwave signal input to the furnace cavity (34). In the preferred embodiment, the second amplifier (20) is a traveling-wave tube (TWT). A power supply (22) is provided for operation of the second amplifier (20). A directional coupler (24) is provided for detecting the direction of a signal and further directing the signal depending on the detected direction. A first power meter (30) is provided for measuring the power delivered to the microwave furnace (32). A second power meter (26) detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load (28).

  2. A digital frequency stabilization system of external cavity diode laser based on LabVIEW FPGA

    NASA Astrophysics Data System (ADS)

    Liu, Zhuohuan; Hu, Zhaohui; Qi, Lu; Wang, Tao

    2015-10-01

    Frequency stabilization for external cavity diode laser has played an important role in physics research. Many laser frequency locking solutions have been proposed by researchers. Traditionally, the locking process was accomplished by analog system, which has fast feedback control response speed. However, analog system is susceptible to the effects of environment. In order to improve the automation level and reliability of the frequency stabilization system, we take a grating-feedback external cavity diode laser as the laser source and set up a digital frequency stabilization system based on National Instrument's FPGA (NI FPGA). The system consists of a saturated absorption frequency stabilization of beam path, a differential photoelectric detector, a NI FPGA board and a host computer. Many functions, such as piezoelectric transducer (PZT) sweeping, atomic saturation absorption signal acquisition, signal peak identification, error signal obtaining and laser PZT voltage feedback controlling, are totally completed by LabVIEW FPGA program. Compared with the analog system, the system built by the logic gate circuits, performs stable and reliable. User interface programmed by LabVIEW is friendly. Besides, benefited from the characteristics of reconfiguration, the LabVIEW program is good at transplanting in other NI FPGA boards. Most of all, the system periodically checks the error signal. Once the abnormal error signal is detected, FPGA will restart frequency stabilization process without manual control. Through detecting the fluctuation of error signal of the atomic saturation absorption spectrum line in the frequency locking state, we can infer that the laser frequency stability can reach 1MHz.

  3. Ajustement automatique des parametres de coupe pour l'obtention de stabilite dynamique en usinage

    NASA Astrophysics Data System (ADS)

    Tabet, Ricardo

    High speed machining has as principal limitation the dynamic stability of the cutting action which can generate premature wear of the machine spindle and the cutting tool, tool breakage and dimensional errors on the machined part. This phenomenon is known in the literature as chatter and is defined as being self-excited vibrations. This master thesis presents an approach applicable to manufacturing environments that allows eliminating chatter in real time during machining of aerospace aluminum alloys before the damaging effect can occur. A control algorithm is developed in order to detect chatter using a microphone and by analyzing the audio signal in the frequency domain. The analysis allows determining precisely the frequency at which the chatter occurs and therefore, the spindle speed is adjusted in order to make the tooth passing frequency equal to the detected chatter frequency. Also, a new feedrate is determined by keeping a constant chip load and within the physical limits of the cutting tool. The new cutting parameters are then sent out to the machine controller as a command using a communication interface between an external computer and the controller. Multiples experimental tests were conducted to validate the effectiveness to detect and suppress chatter. High speed machining tests, between 15 000 and 33 000 RPM, were performed in order to reflect real conditions for aerospace components manufacturing.

  4. Detecting submerged bodies: controlled research using side-scan sonar to detect submerged proxy cadavers.

    PubMed

    Healy, Carrie A; Schultz, John J; Parker, Kenneth; Lowers, Bim

    2015-05-01

    Forensic investigators routinely deploy side-scan sonar for submerged body searches. This study adds to the limited body of literature by undertaking a controlled project to understand how variables affect detection of submerged bodies using side-scan sonar. Research consisted of two phases using small and medium-sized pig (Sus scrofa) carcasses as proxies for human bodies to investigate the effects of terrain, body size, frequency, swath width, and state of decomposition. Results demonstrated that a clear, flat, sandy pond floor terrain was optimal for detection of the target as irregular terrain and/or vegetation are major limitations that can obscure the target. A higher frequency towfish was preferred for small bodies, and a 20 m swath width allowed greater visibility and easier maneuverability of the boat in this environment. Also, the medium-sized carcasses were discernable throughout the 81-day study period, indicating that it is possible to detect bodies undergoing decomposition with side-scan sonar. © 2015 American Academy of Forensic Sciences.

  5. System and method of detecting cavitation in pumps

    DOEpatents

    Lu, Bin; Sharma, Santosh Kumar; Yan, Ting; Dimino, Steven A.

    2017-10-03

    A system and method for detecting cavitation in pumps for fixed and variable supply frequency applications is disclosed. The system includes a controller having a processor programmed to repeatedly receive real-time operating current data from a motor driving a pump, generate a current frequency spectrum from the current data, and analyze current data within a pair of signature frequency bands of the current frequency spectrum. The processor is further programmed to repeatedly determine fault signatures as a function of the current data within the pair of signature frequency bands, repeatedly determine fault indices based on the fault signatures and a dynamic reference signature, compare the fault indices to a reference index, and identify a cavitation condition in a pump based on a comparison between the reference index and a current fault index.

  6. Decreased human leukocyte antigen A*02:01 frequency is associated with risk of glioma and existence of human cytomegalovirus: a case-control study in Northern China.

    PubMed

    Han, Sheng; Deng, Jian; Wang, Zixun; Liu, Huan; Cheng, Wen; Wu, Anhua

    2017-10-01

    Human leukocyte antigens (HLAs) play an important role in host defense against viral infection and tumorigenesis. Human cytomegalovirus (HCMV) has been linked to glioma development. This study investigated the relationship between HLA distribution, presence of HCMV, and glioma development in a Han Chinese population. The study population included 150 glioma patients and 150 tumor-free brain injury control subjects (control-A) matched according to geography, ethnicity, age, and gender. HLA allele frequency was compared between the two groups using peripheral blood samples by PCR sequence-based typing. These data were also compared with HLA frequencies obtained from a Northern Chinese Han population database (control-B). HCMV DNA was detected in the peripheral blood of glioma patients and control group-A by nested PCR. The expression of HCMV proteins IE1-72 and pp65 in tumor tissues was evaluated by immunohistochemistry. The frequency of HLA-A*02:01 was decreased in glioma patients as compared to control group-A and -B (P < 0.001 and P = 0.001, respectively). The age/sex-adjusted odds ratio for HLA-A*02:01 positivity vs. negativity was 0.392 (95% confidence interval 0.225-0.683). HCMV was more frequently detected in the peripheral blood and tumor tissue of HLA-A*02:01-negative glioma patients. HLA-A*02:01 and HCMV were not associated with overall survival. There is a correlation between decreased HLA-A*0201 allele frequency and glioma susceptibility.

  7. Dielectric studies of the paracetamol-lenticular tissue interactions.

    PubMed

    Marzec, E; Olszewski, J; Grześkowiak, E; Kamińska, A; Bienert, A; Iwanik, K

    2011-05-01

    This paper reports on the effect of paracetamol on the dielectric behavior of the rabbit lens. Measurements were performed over the frequency range of 100 Hz-100 kHz in air and at the temperature of 35°C. The frequency dependencies of the relative permittivity and dielectric loss for the control and paracetamol-control lenses are described in terms of a power-low, Debye and Cole-Cole relations. The effect of paracetamol on the dielectric properties of the lens is visible in the lower values of the relative permittivity than those for the control sample at the same frequency. In addition, the relaxations around 18 and 46 kHz for the paracetamol-control lens are shifted to lower frequencies compared with the control lens. The results of this work indicate that the present method is useful in detection of the lens toxicity elicited by overdoses of paracetamol in animal. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. About the Power Generation Confirmation of the Induction Motor and the Influence on the Islanding Detection Device

    NASA Astrophysics Data System (ADS)

    Igarashi, Hironobu; Sato, Takashi; Miyamoto, Kazunori; Kurokawa, Kousuke

    The photovoltaic generation system must have protection device and islanding detection devices to connect with utility line of the electric power company. It is regulated in the technological requirement guideline and the electric equipment technology standard that the country provides. The islanding detection device detected purpose install for blackout due to the accident occurrence of the earth fault and the short-circuit in the utility line. When the islanding detection device detects the power blackout, it is necessary to stop the photovoltaic generation system immediately. If the photovoltaic generation system is not stopped immediately, electricity comes to charge the utility power line very at risk. We had already known that the islanding detection device can't detect the islanding phenomenon, if is there the induction motor in the loads. Authors decided to investigate the influence that the induction motors gave to the islanding detection device. The result was the load condition that the induction motors changed generator the voltage is restraining. Moreover, it was clarified that the time of the islanding was long compared with the load condition of not changing into the state of the generator. The value changes into the reactance of the induction motors according to the frequency change after the supply of electric power line stops. The frequency after the supply of electric power line stops changes for the unbalance the reactive power by the effect of the power rate constancy control with PLL of the power conditioner. However, the induction motors is also to the changing frequency, makes amends for the amount of reactive power, and the change in the frequency after the supply of electric power line stops as a result is controlled. When the frequency changed after the supply of electric power line stopped, it was clarified of the action on the direction where it made amends from the change of the constant for the amount of an invalid electric power, and the possession of the characteristic in which the continuance of the individual operation was promoted.

  9. EEG error potentials detection and classification using time-frequency features for robot reinforcement learning.

    PubMed

    Boubchir, Larbi; Touati, Youcef; Daachi, Boubaker; Chérif, Arab Ali

    2015-08-01

    In thought-based steering of robots, error potentials (ErrP) can appear when the action resulting from the brain-machine interface (BMI) classifier/controller does not correspond to the user's thought. Using the Steady State Visual Evoked Potentials (SSVEP) techniques, ErrP, which appear when a classification error occurs, are not easily recognizable by only examining the temporal or frequency characteristics of EEG signals. A supplementary classification process is therefore needed to identify them in order to stop the course of the action and back up to a recovery state. This paper presents a set of time-frequency (t-f) features for the detection and classification of EEG ErrP in extra-brain activities due to misclassification observed by a user exploiting non-invasive BMI and robot control in the task space. The proposed features are able to characterize and detect ErrP activities in the t-f domain. These features are derived from the information embedded in the t-f representation of EEG signals, and include the Instantaneous Frequency (IF), t-f information complexity, SVD information, energy concentration and sub-bands' energies. The experiment results on real EEG data show that the use of the proposed t-f features for detecting and classifying EEG ErrP achieved an overall classification accuracy up to 97% for 50 EEG segments using 2-class SVM classifier.

  10. Based on optical fiber Michelson interferometer for acoustic emission detection experimental research

    NASA Astrophysics Data System (ADS)

    Liang, Yijun; Qu, Dandan; Deng, Hu

    2013-08-01

    A type of Michelson interferometer with two optical fiber loop reflectors acoustic emission sensor is proposed in the article to detect the vibrations produced by ultrasonic waves propagating in a solid body. Two optical fiber loop reflectors are equivalent to the sensing arm and the reference arm instead of traditional Michelson interferometer end reflecter Theoretical analyses indicate that the sensitivity of the system has been remarkably increased because of the decrease of the losses of light energy. The best operating point of optical fiber sensor is fixed by theoretical derivation and simulation of computer, and the signal frequency which is detected by the sensor is the frequency of input signal. PZT (Piezoelectric Ceramic) is powered by signal generator as known ultrasonic source, The Polarization controller is used to make the reflected light interference,The fiber length is changed by adjusting the DC voltage on the PZT with the fiber loop to make the sensor system response that ΔΦ is closed to π/2. the signal basis frequency detected by the sensor is the frequency of the input signal. Then impacts the surface of the marble slab with home-made mechanical acoustic emission source. And detect it. and then the frequency characteristic of acoustic emission signal is obtained by Fourier technique. The experimental results indicate that the system can identify the frequency characteristic of acoustic emission signal, and it can be also used to detect the surface feeble vibration which is generated by ultrasonic waves propagating in material structure.

  11. Effect of parameters in moving average method for event detection enhancement using phase sensitive OTDR

    NASA Astrophysics Data System (ADS)

    Kwon, Yong-Seok; Naeem, Khurram; Jeon, Min Yong; Kwon, Il-bum

    2017-04-01

    We analyze the relations of parameters in moving average method to enhance the event detectability of phase sensitive optical time domain reflectometer (OTDR). If the external events have unique frequency of vibration, then the control parameters of moving average method should be optimized in order to detect these events efficiently. A phase sensitive OTDR was implemented by a pulsed light source, which is composed of a laser diode, a semiconductor optical amplifier, an erbium-doped fiber amplifier, a fiber Bragg grating filter, and a light receiving part, which has a photo-detector and high speed data acquisition system. The moving average method is operated with the control parameters: total number of raw traces, M, number of averaged traces, N, and step size of moving, n. The raw traces are obtained by the phase sensitive OTDR with sound signals generated by a speaker. Using these trace data, the relation of the control parameters is analyzed. In the result, if the event signal has one frequency, then the optimal values of N, n are existed to detect the event efficiently.

  12. Doppler flowmeter

    DOEpatents

    Karplus, H.H.B.; Raptis, A.C.

    1981-11-13

    A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.

  13. Doppler flowmeter

    DOEpatents

    Karplus, Henry H. B.; Raptis, Apostolos C.

    1983-01-01

    A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.

  14. Auditory Deficits in Amusia Extend Beyond Poor Pitch Perception

    PubMed Central

    Whiteford, Kelly L.; Oxenham, Andrew J.

    2017-01-01

    Congenital amusia is a music perception disorder believed to reflect a deficit in fine-grained pitch perception and/or short-term or working memory for pitch. Because most measures of pitch perception include memory and segmentation components, it has been difficult to determine the true extent of pitch processing deficits in amusia. It is also unclear whether pitch deficits persist at frequencies beyond the range of musical pitch. To address these questions, experiments were conducted with amusics and matched controls, manipulating both the stimuli and the task demands. First, we assessed pitch discrimination at low (500 Hz and 2000 Hz) and high (8000 Hz) frequencies using a three-interval forced-choice task. Amusics exhibited deficits even at the highest frequency, which lies beyond the existence region of musical pitch. Next, we assessed the extent to which frequency coding deficits persist in one- and two-interval frequency-modulation (FM) and amplitude-modulation (AM) detection tasks at 500 Hz at slow (fm = 4 Hz) and fast (fm = 20 Hz) modulation rates. Amusics still exhibited deficits in one-interval FM detection tasks that should not involve memory or segmentation. Surprisingly, amusics were also impaired on AM detection, which should not involve pitch processing. Finally, direct comparisons between the detection of continuous and discrete FM demonstrated that amusics suffer deficits both in coding and segmenting pitch information. Our results reveal auditory deficits in amusia extending beyond pitch perception that are subtle when controlling for memory and segmentation, and are likely exacerbated in more complex contexts such as musical listening. PMID:28315696

  15. Quantum sensing with arbitrary frequency resolution

    NASA Astrophysics Data System (ADS)

    Boss, J. M.; Cujia, K. S.; Zopes, J.; Degen, C. L.

    2017-05-01

    Quantum sensing takes advantage of well-controlled quantum systems for performing measurements with high sensitivity and precision. We have implemented a concept for quantum sensing with arbitrary frequency resolution, independent of the qubit probe and limited only by the stability of an external synchronization clock. Our concept makes use of quantum lock-in detection to continuously probe a signal of interest. Using the electronic spin of a single nitrogen-vacancy center in diamond, we demonstrate detection of oscillating magnetic fields with a frequency resolution of 70 microhertz over a megahertz bandwidth. The continuous sampling further guarantees an enhanced sensitivity, reaching a signal-to-noise ratio in excess of 104 for a 170-nanotesla test signal measured during a 1-hour interval. Our technique has applications in magnetic resonance spectroscopy, quantum simulation, and sensitive signal detection.

  16. Analysis on frequency response of trans-impedance amplifier (TIA) for signal-to-noise ratio (SNR) enhancement in optical signal detection system using lock-in amplifier (LIA)

    NASA Astrophysics Data System (ADS)

    Kim, Ji-Hoon; Jeon, Su-Jin; Ji, Myung-Gi; Park, Jun-Hee; Choi, Young-Wan

    2017-02-01

    Lock-in amplifier (LIA) has been widely used in optical signal detection systems because it can measure small signal under high noise level. Generally, The LIA used in optical signal detection system is composed of transimpedance amplifier (TIA), phase sensitive detector (PSD) and low pass filter (LPF). But commercial LIA using LPF is affected by flicker noise. To avoid flicker noise, there is 2ω detection LIA using BPF. To improve the dynamic reserve (DR) of the 2ω LIA, the signal to noise ratio (SNR) of the TIA should be improved. According to the analysis of frequency response of the TIA, the noise gain can be minimized by proper choices of input capacitor (Ci) and feed-back network in the TIA in a specific frequency range. In this work, we have studied how the SNR of the TIA can be improved by a proper choice of frequency range. We have analyzed the way to control this frequency range through the change of passive component in the TIA. The result shows that the variance of the passive component in the TIA can change the specific frequency range where the noise gain is minimized in the uniform gain region of the TIA.

  17. Design and performance of an ultra-wideband stepped-frequency radar with precise frequency control for landmine and IED detection

    NASA Astrophysics Data System (ADS)

    Phelan, Brian R.; Sherbondy, Kelly D.; Ranney, Kenneth I.; Narayanan, Ram M.

    2014-05-01

    The Army Research Laboratory (ARL) has developed an impulse-based vehicle-mounted forward-looking ultra- wideband (UWB) radar for imaging buried landmines and improvised explosive devices (IEDs). However, there is no control of the radiated spectrum in this system. As part of ARL's Partnerships in Research Transition (PIRT) program, the above deficiency is addressed by the design of a Stepped-Frequency Radar (SFR) which allows for precise control over the radiated spectrum, while still maintaining an effective ultra-wide bandwidth. The SFR utilizes a frequency synthesizer which can be configured to excise prohibited and interfering frequency bands and also implement frequency-hopping capabilities. The SFR is designed to be a forward-looking ground- penetrating (FLGPR) Radar utilizing a uniform linear array of sixteen (16) Vivaldi notch receive antennas and two (2) Quad-ridge horn transmit antennas. While a preliminary SFR consisting of four (4) receive channels has been designed, this paper describes major improvements to the system, and an analysis of expected system performance. The 4-channel system will be used to validate the SFR design which will eventually be augmented in to the full 16-channel system. The SFR has an operating frequency band which ranges from 300 - 2000 MHz, and a minimum frequency step-size of 1 MHz. The radar system is capable of illuminating range swaths that have maximum extents of 30 to 150 meters (programmable). The transmitter has the ability to produce approximately -2 dBm/MHz average power over the entire operating frequency range. The SFR will be used to determine the practicality of detecting and classifying buried and concealed landmines and IEDs from safe stand-off distances.

  18. [Association between polymorphism in DVWA and IL-1beta and Kashin-Beck disease].

    PubMed

    Y U, Min; Guo, Xiong; Gao, Xiao-Yun; Lai, Jiang-Hua; Tu, Qian-Qian

    2010-07-01

    To investigate the association between IL-1beta and DVWA gene and Kashin-Beck disease (KBD). Peripheral genomic DNA were extracted from 105 patients with KBD and 98 healthy controls. PCR-RFLP were performed to detect SNP loci of IL-1beta gene and DVWA gene. The patients with KBD had significantly higher frequency of rs16944 (IL-1beta) locus (chi2 = 24.28, P < 0.001) and single allele frequency of rs16944 (chi2 = 5.683, P = 0.0171) than the healthy controls. There were no significant differences in genotype frequencies,single allele frequencies and haplotypes in rs4685241 and rs1143627 between the patients with KBD and the healthy controls. rs16944 (IL-1beta) is associated with KBD.

  19. Continuous-wave cavity ringdown spectroscopy based on the control of cavity reflection.

    PubMed

    Li, Zhixin; Ma, Weiguang; Fu, Xiaofang; Tan, Wei; Zhao, Gang; Dong, Lei; Zhang, Lei; Yin, Wangbao; Jia, Suotang

    2013-07-29

    A new type of continuous-wave cavity ringdown spectrometer based on the control of cavity reflection for trace gas detection was designed and evaluated. The technique separated the acquisitions of the ringdown event and the trigger signal to optical switch by detecting the cavity reflection and transmission, respectively. A detailed description of the time sequence of the measurement process was presented. In order to avoid the wrong extraction of ringdown time encountered accidentally in fitting procedure, the laser frequency and cavity length were scanned synchronously. Based on the statistical analysis of measured ringdown times, the frequency normalized minimum detectable absorption in the reflection control mode was 1.7 × 10(-9)cm(-1)Hz(-1/2), which was 5.4 times smaller than that in the transmission control mode. However the signal-to-noise ratio of the absorption spectrum was only 3 times improved since the etalon effect existed. Finally, the peak absorption coefficients of the C(2)H(2) transition near 1530.9nm under different pressures showed a good agreement with the theoretical values.

  20. Correlated evolution between hearing sensitivity and social calls in bats

    PubMed Central

    Bohn, Kirsten M; Moss, Cynthia F; Wilkinson, Gerald S

    2006-01-01

    Echolocating bats are auditory specialists, with exquisite hearing that spans several octaves. In the ultrasonic range, bat audiograms typically show highest sensitivity in the spectral region of their species-specific echolocation calls. Well-developed hearing in the audible range has been commonly attributed to a need to detect sounds produced by prey. However, bat pups often emit isolation calls with low-frequency components that facilitate mother–young reunions. In this study, we examine whether low-frequency hearing in bats exhibits correlated evolution with (i) body size; (ii) high-frequency hearing sensitivity or (iii) pup isolation call frequency. Using published audiograms, we found that low-frequency hearing sensitivity is not dependent on body size but is related to high-frequency hearing. After controlling for high-frequency hearing, we found that low-frequency hearing exhibits correlated evolution with isolation call frequency. We infer that detection and discrimination of isolation calls have favoured enhanced low-frequency hearing because accurate parental investment is critical: bats have low reproductive rates, non-volant altricial young and must often identify their pups within large crèches. PMID:17148288

  1. A spectral power analysis of driving behavior changes during the transition from nondistraction to distraction.

    PubMed

    Wang, Yuan; Bao, Shan; Du, Wenjun; Ye, Zhirui; Sayer, James R

    2017-11-17

    This article investigated and compared frequency domain and time domain characteristics of drivers' behaviors before and after the start of distracted driving. Data from an existing naturalistic driving study were used. Fast Fourier transform (FFT) was applied for the frequency domain analysis to explore drivers' behavior pattern changes between nondistracted (prestarting of visual-manual task) and distracted (poststarting of visual-manual task) driving periods. Average relative spectral power in a low frequency range (0-0.5 Hz) and the standard deviation in a 10-s time window of vehicle control variables (i.e., lane offset, yaw rate, and acceleration) were calculated and further compared. Sensitivity analyses were also applied to examine the reliability of the time and frequency domain analyses. Results of the mixed model analyses from the time and frequency domain analyses all showed significant degradation in lateral control performance after engaging in visual-manual tasks while driving. Results of the sensitivity analyses suggested that the frequency domain analysis was less sensitive to the frequency bandwidth, whereas the time domain analysis was more sensitive to the time intervals selected for variation calculations. Different time interval selections can result in significantly different standard deviation values, whereas average spectral power analysis on yaw rate in both low and high frequency bandwidths showed consistent results, that higher variation values were observed during distracted driving when compared to nondistracted driving. This study suggests that driver state detection needs to consider the behavior changes during the prestarting periods, instead of only focusing on periods with physical presence of distraction, such as cell phone use. Lateral control measures can be a better indicator of distraction detection than longitudinal controls. In addition, frequency domain analyses proved to be a more robust and consistent method in assessing driving performance compared to time domain analyses.

  2. Distribution of oral mucosal bacteria with mecA in patients undergoing hematopoietic cell transplantation.

    PubMed

    Ebinuma, Takayuki; Soga, Yoshihiko; Sato, Takamaro; Matsunaga, Kazuyuki; Kudo, Chieko; Maeda, Hiroshi; Maeda, Yoshinobu; Tanimoto, Mitsune; Takashiba, Shogo

    2014-06-01

    We recently reported frequent detection of antibiotic-resistant bacteria on the oral mucosa during the period of hematopoietic cell transplantation (HCT) and suggested an association between oral mucositis and antibiotic-resistant bacterial infection. Methicillin-resistant Staphylococcus spp. were frequently detected, and the oral cavity may be a reservoir of the gene mediating methicillin resistance, mecA. Here, we examined the frequency of mecA carriers in patients undergoing HCT. Fifty-nine patients (male (M) = 37, female (F) = 22, 47.3 ± 11.0 years) receiving HCT were enrolled in this study. Buccal swab samples were obtained four times from day -7 to day +20 (once/week), and mecA was detected by PCR. Fifty-two subjects without systemic disease, who completed dental treatment, especially periodontal treatment (M = 21, F = 31, 55.4 ± 14.2 years), were also enrolled as controls and checked for mecA on the oral mucosa. Seventy-six percent (45/59) of the HCT patients carried mecA at least once in the study period (days -7 to +20), while no control subjects had mecA. The frequency of mecA carriers was 19.2 % from days -7 to -1, while it was significantly increased on days +7 to +13 and +14 to +20, with frequencies of 60.9 and 63.2 %, respectively (P < 0.01, ANOVA). mecA was detected in oral mucosa of patients undergoing HCT. The high detection frequency of staphylococci resistant to penicillin and beta-lactams in our recent report was supported.

  3. Magnetoencephalography for the Detection of Intervention Effects of a Specific Nutrient Combination in Patients with Mild Alzheimer’s Disease: Results from an Exploratory Double-Blind, Randomized, Controlled Study

    PubMed Central

    van Straaten, Elisabeth C. W.; de Waal, Hanneke; Lansbergen, Marieke M.; Scheltens, Philip; Maestu, Fernando; Nowak, Rafal; Hillebrand, Arjan; Stam, Cornelis J.

    2016-01-01

    Synaptic loss is an early pathological finding in Alzheimer’s disease (AD) and correlates with memory impairment. Changes in macroscopic brain activity measured with electro- and magnetoencephalography (EEG and MEG) in AD indicate synaptic changes and may therefore serve as markers of intervention effects in clinical trials. EEG peak frequency and functional networks have shown, in addition to improved memory performance, to be sensitive to detect an intervention effect in mild AD patients of the medical food Souvenaid containing the specific nutrient combination Fortasyn® Connect, which is designed to enhance synapse formation and function. Here, we explore the value of MEG, with higher spatial resolution than EEG, in identifying intervention effects of the nutrient combination by comparing MEG spectral measures, functional connectivity, and networks between an intervention and a control group. Quantitative markers describing spectral properties, functional connectivity, and graph theoretical aspects of MEG from the exploratory 24-week, double-blind, randomized, controlled Souvenir II MEG sub-study (NTR1975, http://www.trialregister.nl) in drug naïve patients with mild AD were compared between a test group (n = 27), receiving Souvenaid, and a control group (n = 28), receiving an isocaloric control product. The groups were unbalanced at screening with respect to Mini-Mental State Examination. Peak frequencies of MEG were compared with EEG peak frequencies, recorded in the same patients at similar time points, were compared with respect to sensitivity to intervention effects. No consistent statistically significant intervention effects were detected. In addition, we found no difference in sensitivity between MEG and EEG peak frequency. This exploratory study could not unequivocally establish the value of MEG in detecting interventional effects on brain activity, possibly due to small sample size and unbalanced study groups. We found no indication that the difference could be attributed to a lack of sensitivity of MEG compared with EEG. MEG in randomized controlled trials is feasible but its value to disclose intervention effects of Souvenaid in mild AD patients needs to be studied further. PMID:27799918

  4. Magnetoencephalography for the Detection of Intervention Effects of a Specific Nutrient Combination in Patients with Mild Alzheimer's Disease: Results from an Exploratory Double-Blind, Randomized, Controlled Study.

    PubMed

    van Straaten, Elisabeth C W; de Waal, Hanneke; Lansbergen, Marieke M; Scheltens, Philip; Maestu, Fernando; Nowak, Rafal; Hillebrand, Arjan; Stam, Cornelis J

    2016-01-01

    Synaptic loss is an early pathological finding in Alzheimer's disease (AD) and correlates with memory impairment. Changes in macroscopic brain activity measured with electro- and magnetoencephalography (EEG and MEG) in AD indicate synaptic changes and may therefore serve as markers of intervention effects in clinical trials. EEG peak frequency and functional networks have shown, in addition to improved memory performance, to be sensitive to detect an intervention effect in mild AD patients of the medical food Souvenaid containing the specific nutrient combination Fortasyn ® Connect, which is designed to enhance synapse formation and function. Here, we explore the value of MEG, with higher spatial resolution than EEG, in identifying intervention effects of the nutrient combination by comparing MEG spectral measures, functional connectivity, and networks between an intervention and a control group. Quantitative markers describing spectral properties, functional connectivity, and graph theoretical aspects of MEG from the exploratory 24-week, double-blind, randomized, controlled Souvenir II MEG sub-study (NTR1975, http://www.trialregister.nl) in drug naïve patients with mild AD were compared between a test group ( n  = 27), receiving Souvenaid, and a control group ( n  = 28), receiving an isocaloric control product. The groups were unbalanced at screening with respect to Mini-Mental State Examination. Peak frequencies of MEG were compared with EEG peak frequencies, recorded in the same patients at similar time points, were compared with respect to sensitivity to intervention effects. No consistent statistically significant intervention effects were detected. In addition, we found no difference in sensitivity between MEG and EEG peak frequency. This exploratory study could not unequivocally establish the value of MEG in detecting interventional effects on brain activity, possibly due to small sample size and unbalanced study groups. We found no indication that the difference could be attributed to a lack of sensitivity of MEG compared with EEG. MEG in randomized controlled trials is feasible but its value to disclose intervention effects of Souvenaid in mild AD patients needs to be studied further.

  5. Selective Impairment in Frequency Discrimination in a Mouse Model of Tinnitus

    PubMed Central

    Mwilambwe-Tshilobo, Laetitia; Davis, Andrew J. O.; Aizenberg, Mark; Geffen, Maria N.

    2015-01-01

    Tinnitus is an auditory disorder, which affects millions of Americans, including active duty service members and veterans. It is manifested by a phantom sound that is commonly restricted to a specific frequency range. Because tinnitus is associated with hearing deficits, understanding how tinnitus affects hearing perception is important for guiding therapies to improve the quality of life in this vast group of patients. In a rodent model of tinnitus, prolonged exposure to a tone leads to a selective decrease in gap detection in specific frequency bands. However, whether and how hearing acuity is affected for sounds within and outside those frequency bands is not well understood. We induced tinnitus in mice by prolonged exposure to a loud mid-range tone, and behaviorally assayed whether mice exhibited a change in frequency discrimination acuity for tones embedded within the mid-frequency range and high-frequency range at 1, 4, and 8 weeks post-exposure. A subset of tone-exposed mice exhibited tinnitus-like symptoms, as demonstrated by selective deficits in gap detection, which were restricted to the high frequency range. These mice exhibited impaired frequency discrimination both for tones in the mid-frequency range and high-frequency range. The remaining tone exposed mice, which did not demonstrate behavioral evidence of tinnitus, showed temporary deficits in frequency discrimination for tones in the mid-frequency range, while control mice remained unimpaired. Our findings reveal that the high frequency-specific deficits in gap detection, indicative of tinnitus, are associated with impairments in frequency discrimination at the frequency of the presumed tinnitus. PMID:26352864

  6. A study of universal modulation techniques applied to satellite data collection

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A universal modulation and frequency control system for use with data collection platform (DCP) transmitters is examined. The final design discussed can, under software/firmwave control, generate all of the specific digital data modulation formats currently used in the NASA satellite data collection service and can simultaneously synthesize the proper RF carrier frequencies employed. A novel technique for DCP time and frequency control is presented. The emissions of NBS radio station WWV/WWVH are received, detected, and finally decoded in microcomputer software to generate a highly accurate time base for the platform; with the assistance of external hardware, the microcomputer also directs the recalibration of all DCP oscillators to achieve very high frequency accuracies and low drift rates versus temperature, supply voltage, and time. The final programmable DCP design also employs direct microcomputer control of data reduction, formatting, transmitter switching, and system power management.

  7. Method and apparatus for monitoring the rotating frequency of de-energized induction motors

    DOEpatents

    Mikesell, H.E.; Lucy, E.

    1998-02-03

    The rotational speed of a coasting induction motor is measured by sensing e residual electrical voltages at the power terminals of the motor, thus eliminating the need for conventional tachometer equipment, additional mechanical components or modifications to the induction motor itself. The power terminal voltage signal is detected and transformed into a DC voltage proportional to the frequency of the signal. This DC voltage can be input to the control system of a variable frequency motor controller to regulate the output characteristics thereof relative to the speed of the coasting motor. 6 figs.

  8. Method and apparatus for monitoring the rotating frequency of de-energized induction motors

    DOEpatents

    Mikesell, Harvey E.; Lucy, Eric

    1998-01-01

    The rotational speed of a coasting induction motor is measured by sensing e residual electrical voltages at the power terminals of the motor, thus eliminating the need for conventional tachometer equipment, additional mechanical components or modifications to the induction motor itself. The power terminal voltage signal is detected and transformed into a DC voltage proportional to the frequency of the signal. This DC voltage can be input to the control system of a variable frequency motor controller to regulate the output characteristics thereof relative to the speed of the coasting motor.

  9. The HABP2 G534E Variant Is an Unlikely Cause of Familial Nonmedullary Thyroid Cancer

    PubMed Central

    Sahasrabudhe, Ruta; Stultz, Jacob; Williamson, John; Lott, Paul; Estrada, Ana; Bohorquez, Mabel; Palles, Claire; Polanco-Echeverry, Guadalupe; Jaeger, Emma; Martin, Lynn; Echeverry, Maria Magdalena; Tomlinson, Ian

    2016-01-01

    Context: A recent study reported the nonsynonymous G534E (rs7080536, allele A) variant in the HABP2 gene as causal in familial nonmedullary thyroid cancer (NMTC). Objective: The objective of this study was to evaluate the causality of HABP2 G534E in the TCUKIN study, a multicenter population-based study of NMTC cases from the British Isles. Design and Setting: A case-control analysis of rs7080536 genotypes was performed using 2105 TCUKIN cases and 5172 UK controls. Participants: Cases comprised 2105 NMTC cases. Patient subgroups with papillary (n = 1056), follicular (n = 691), and Hürthle cell (n = 86) thyroid cancer cases were studied separately. Controls comprised 5172 individuals from the 1958 Birth Cohort and the National Blood Donor Service study. The controls had previously been genotyped using genome-wide single nucleotide polymorphism arrays by the Wellcome Trust Case Control Consortium study. Outcome Measures: Association between HABP2 G534E (rs7080536A) and NMTC risk was evaluated using logistic regression. Results: The frequency of the HABP2 G534E was 4.2% in cases and 4.6% in controls. We did not detect an association between this variant and NMTC risk (odds ratio [OR] = 0.896; 95% confidence interval, 0.746–1.071; P = .233). We also failed to detect an association between the HABP2 G534E and cases with papillary (1056 cases; G534E frequency = 3.5%; OR = 0.74; P = .017), follicular (691 cases; G534E frequency = 4.7%; OR = 1.00; P = 1.000), or Hürthle cell (86 cases; G534E frequency = 6.3%; OR = 1.40; P = .279) histology. Conclusions: We found that HABP2 G534E is a low-to-moderate frequency variant in the British Isles and failed to detect an association with NMTC risk, independent of histological type. Hence, our study does not implicate HABP2 G534E or a correlated polymorphism in familial NMTC, and additional data are required before using this variant in NMTC risk assessment. PMID:26691890

  10. The HABP2 G534E variant is an unlikely cause of familial non-medullary thyroid cancer.

    PubMed

    Sahasrabudhe, Ruta; Stultz, Jacob; Williamson, John; Lott, Paul; Estrada, Ana; Bohorquez, Mabel; Palles, Claire; Polanco-Echeverry, Guadalupe; Jaeger, Emma; Martin, Lynn; Magdalena Echeverry, Maria; Tomlinson, Ian; Carvajal-Carmona, Luis G

    2016-03-01

    A recent study reported the non-synonymous G534E (rs7080536, allele A) variant in the HABP2 gene as causal in familial non-medullary thyroid cancer (NMTC). The objective of this study was to evaluate the causality of HABP2 G534E in the TCUKIN study, a multi-center population based study of NMTC cases from the British Isles. A case-control analysis of rs7080536 genotypes was performed using 2,105 TCUKIN cases and 5,172 UK controls. Cases comprised 2,105 NMTC cases. Patients sub-groups with papillary (N=1,056), follicular (N=691) and Hurthle cell (N=86) TC cases were studied separately. Controls comprised 5,172 individuals from the 1958 Birth Cohort (58C) and the National Blood Donor Service (NBS) study. The controls had previously been genotyped using genome-wide SNP arrays by the Wellcome Trust Case Control Consortium study. Measures: Association between HABP2 G534E (rs7080536A) and NMTC risk was evaluated using logistic regression. The frequency of HABP2 G534E was 4.2% in cases and 4.6% in controls. We did not detect an association between this variant and NMTC risk (OR=0.896, 95% CI: 0.746-1.071, P=0.233). We also failed to detect an association between HABP2 G534E and cases with papillary (1056 cases, G534E frequency= 3.5%, OR=0.74, P=0.017), follicular (691 cases, G534E frequency= 4.7%, OR=1.00, P=1.000) or Hurthle cell (86 cases, G534E frequency= 6.3%, OR=1.40, P=0.279) histology. We found that HABP2 G534E is a low-to-moderate frequency variant in the British Isles and failed to detect an association with NMTC risk, independent of histological type. Hence, our study does not implicate HABP2 G534E or a correlated polymorphism in familial NMTC and additional data are required before using this variant in NMTC risk assessment.

  11. Deterrence Requirements and Arms Control Responsibilities: The United State’s Obligation to Ratify the Comprehensive Nuclear Test Ban Treaty

    DTIC Science & Technology

    2010-02-17

    systems to detect a nuclear explosion; seismic, hydroacoustic, infrasound , and radionuclide. These stations are able to detect a nuclear explosion as...These sites detect thousands of seismic events a year, mainly from earthquakes and mining explosions, and have proved effective in detecting past...that detect sound waves in the oceans, and the 60 infrasound stations above ground that detect ultra-low frequency sound waves emitted by nuclear

  12. Acoustic emission intrusion detector

    DOEpatents

    Carver, Donald W.; Whittaker, Jerry W.

    1980-01-01

    An intrusion detector is provided for detecting a forcible entry into a secured structure while minimizing false alarms. The detector uses a piezoelectric crystal transducer to sense acoustic emissions. The transducer output is amplified by a selectable gain amplifier to control the sensitivity. The rectified output of the amplifier is applied to a Schmitt trigger circuit having a preselected threshold level to provide amplitude discrimination. Timing circuitry is provided which is activated by successive pulses from the Schmitt trigger which lie within a selected time frame for frequency discrimination. Detected signals having proper amplitude and frequency trigger an alarm within the first complete cycle time of a detected acoustical disturbance signal.

  13. HFE gene mutation and iron overload in Egyptian pediatric acute lymphoblastic leukemia survivors: a single-center study.

    PubMed

    El-Rashedi, Farida H; El-Hawy, Mahmoud A; El-Hefnawy, Sally M; Mohammed, Mona M

    2017-08-01

    Hereditary hemochromatosis gene (HFE) mutations have a role in iron overload in pediatric acute lymphoblastic leukemia (ALL) survivors. We aimed to evaluate the genotype frequency and allelic distribution of the two HFE gene mutations (C282Y and H63D) in a sample of Egyptian pediatric ALL survivors and to detect the impact of these two mutations on their iron profile. This study was performed on 35 ALL survivors during their follow-up visits to the Hematology and Oncology Unit, Pediatric Department, Menoufia University Hospitals. Thirty-five healthy children of matched age and sex were chosen as controls. After completing treatment course, ALL survivors were screened for the prevalence of these two mutations by polymerase chain reaction-restriction fragment length polymorphism. Serum ferritin levels were measured by an enzyme-linked immunosorbent assay technique (ELISA). C282Y mutation cannot be detected in any of the 35 survivors or the 35 controls. The H63D heterozygous state (CG) was detected in 28.6% of the survivors group and in 20% of controls, while the H63D homozygous (GG) state was detected in 17.1% of survivors. No compound heterozygosity (C282Y/H63D) was detected at both groups with high G allele frequency (31.4%) in survivors more than controls (10%). There were significant higher levels of iron parameters in homozygote survivors than heterozygotes and the controls. H63D mutation aggravates the iron overload status in pediatric ALL survivors.

  14. Precision asteroseismology of the pulsating white dwarf GD 1212 using a two-wheel-controlled Kepler spacecraft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermes, J. J.; Charpinet, S.; Barclay, Thomas

    We present a preliminary analysis of the cool pulsating white dwarf (WD) GD 1212, enabled by more than 11.5 days of space-based photometry obtained during an engineering test of the two-reaction-wheel-controlled Kepler spacecraft. We detect at least 19 independent pulsation modes, ranging from 828.2-1220.8 s, and at least 17 nonlinear combination frequencies of those independent pulsations. Our longest uninterrupted light curve, 9.0 days in length, evidences coherent difference frequencies at periods inaccessible from the ground, up to 14.5 hr, the longest-period signals ever detected in a pulsating WD. These results mark some of the first science to come from amore » two-wheel-controlled Kepler spacecraft, proving the capability for unprecedented discoveries afforded by extending Kepler observations to the ecliptic.« less

  15. Induction machine bearing faults detection based on a multi-dimensional MUSIC algorithm and maximum likelihood estimation.

    PubMed

    Elbouchikhi, Elhoussin; Choqueuse, Vincent; Benbouzid, Mohamed

    2016-07-01

    Condition monitoring of electric drives is of paramount importance since it contributes to enhance the system reliability and availability. Moreover, the knowledge about the fault mode behavior is extremely important in order to improve system protection and fault-tolerant control. Fault detection and diagnosis in squirrel cage induction machines based on motor current signature analysis (MCSA) has been widely investigated. Several high resolution spectral estimation techniques have been developed and used to detect induction machine abnormal operating conditions. This paper focuses on the application of MCSA for the detection of abnormal mechanical conditions that may lead to induction machines failure. In fact, this paper is devoted to the detection of single-point defects in bearings based on parametric spectral estimation. A multi-dimensional MUSIC (MD MUSIC) algorithm has been developed for bearing faults detection based on bearing faults characteristic frequencies. This method has been used to estimate the fundamental frequency and the fault related frequency. Then, an amplitude estimator of the fault characteristic frequencies has been proposed and fault indicator has been derived for fault severity measurement. The proposed bearing faults detection approach is assessed using simulated stator currents data, issued from a coupled electromagnetic circuits approach for air-gap eccentricity emulating bearing faults. Then, experimental data are used for validation purposes. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  16. An Accurate Transmitting Power Control Method in Wireless Communication Transceivers

    NASA Astrophysics Data System (ADS)

    Zhang, Naikang; Wen, Zhiping; Hou, Xunping; Bi, Bo

    2018-01-01

    Power control circuits are widely used in transceivers aiming at stabilizing the transmitted signal power to a specified value, thereby reducing power consumption and interference to other frequency bands. In order to overcome the shortcomings of traditional modes of power control, this paper proposes an accurate signal power detection method by multiplexing the receiver and realizes transmitting power control in the digital domain. The simulation results show that this novel digital power control approach has advantages of small delay, high precision and simplified design procedure. The proposed method is applicable to transceivers working at large frequency dynamic range, and has good engineering practicability.

  17. Effect of Concurrent Visual Feedback Frequency on Postural Control Learning in Adolescents.

    PubMed

    Marco-Ahulló, Adrià; Sánchez-Tormo, Alexis; García-Pérez, José A; Villarrasa-Sapiña, Israel; González, Luis M; García-Massó, Xavier

    2018-04-13

    The purpose was to find better augmented visual feedback frequency (100% or 67%) for learning a balance task in adolescents. Thirty subjects were divided randomly into a control group, and 100% and 67% feedback groups. The three groups performed pretest (3 trials), practice (12 trials), posttest (3 trials) and retention (3 trials, 24 hours later). The reduced feedback group showed lower RMS in the posttest than in the pretest (p = 0.04). The control and reduced feedback groups showed significant lower median frequency in the posttest than in the pretest (p < 0.05). Both feedback groups showed lower values in retention than in the pretest (p < 0.05). Even when the effect of feedback frequency could not be detected in motor learning, 67% of the feedback was recommended for motor adaptation.

  18. A closed-loop phase-locked interferometer for wide bandwidth position sensing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, Andrew J., E-mail: Andrew.Fleming@Newcastle.edu.au; Routley, Ben S., E-mail: Ben.Routley@Newcastle.edu.au

    This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization ormore » modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.« less

  19. Simultaneously frequency down-conversion, independent multichannel phase shifting and zero-IF receiving using a phase modulator in a sagnac loop and balanced detection

    NASA Astrophysics Data System (ADS)

    Zhu, Zihang; Zhao, Shanghong; Li, Xuan; Lin, Tao; Hu, Dapeng

    2018-03-01

    Photonic microwave frequency down-conversion with independent multichannel phase shifting and zero-intermediate frequency (IF) receiving is proposed and demonstrated by simulation. By combined use of a phase modulator (PM) in a sagnac loop and an optical bandpass filter (OBPF), orthogonal polarized carrier suppression single sideband (CS-SSB) signals are obtained. By adjusting the polarization controllers (PCs) to introduce the phase difference in the optical domain and using balanced detection to eliminate the direct current components, the phase of the generated IF signal can be arbitrarily tuned. Besides, the radio frequency (RF) vector signal can be also frequency down-converted to baseband directly by choosing two quadrature channels. In the simulation, high gain and continuously tunable phase shifts over the 360 degree range are verified. Furthermore, 2.5 Gbit/s RF vector signals centered at 10 GHz with different modulation formats are successfully demodulated.

  20. Susceptibility of linear and nonlinear otoacoustic emission components to low-dose styrene exposure.

    PubMed

    Tognola, G; Chiaramello, E; Sisto, R; Moleti, A

    2015-03-01

    To investigate potential susceptibility of active cochlear mechanisms to low-level styrene exposure by comparing TEOAEs in workers and controls. Two advanced analysis techniques were applied to detect sub-clinical changes in linear and nonlinear cochlear mechanisms of OAE generation: the wavelet transform to decompose TEOAEs into time-frequency components and extract signal-to-noise ratio and latency of each component, and the bispectrum to detect and extract nonlinear TEOAE contributions as quadratic frequency couplings (QFCs). Two cohorts of workers were examined: subjects exposed exclusively to styrene (N = 9), and subjects exposed to styrene and noise (N = 6). The control group was perfectly matched by age and sex to the exposed group. Exposed subjects showed significantly lowered SNR in TEOAE components at mid-to-high frequencies (above 1.6 kHz) and a shift of QFC distribution towards lower frequencies than controls. No systematic differences were observed in latency. Low-level styrene exposure may have induced a modification of cochlear functionality as concerns linear and nonlinear OAE generation mechanisms. The lack of change in latency seems to suggest that the OAE components, where generation region and latency are tightly coupled, may not have been affected by styrene and noise exposure levels considered here.

  1. Use of Fiber Bragg Grating (FBG) sensors for performing automated bridge pier structural damage detection and scour monitoring.

    DOT National Transportation Integrated Search

    2012-04-01

    The goal of this study was to evaluate the performance of Fiber Bragg Grating (FBG) sensors able to detect impacts with : different frequencies on a bridge pier. The FBG technology was evaluated under controlled conditions in a laboratory : flume set...

  2. Occurrence and concentrations of pharmaceutical compounds in deep groundwater used for public drinking-water supply in California

    USGS Publications Warehouse

    Fram, Miranda S.; Belitz, Kenneth

    2011-01-01

    Pharmaceutical compounds were detected at low concentrations in 2.3% of 1231 samples of groundwater (median depth to top of screened interval in wells = 61 m) used for public drinking-water supply in California. Samples were collected statewide for the California State Water Resources Control Board's Groundwater Ambient Monitoring and Assessment (GAMA) Program. Of 14 pharmaceutical compounds analyzed, 7 were detected at concentrations greater than or equal to method detection limits: acetaminophen (used as an analgesic, detection frequency 0.32%, maximum concentration 1.89 μg/L), caffeine (stimulant, 0.24%, 0.29 μg/L), carbamazepine (mood stabilizer, 1.5%, 0.42 μg/L), codeine (opioid analgesic, 0.16%, 0.214 μg/L), p-xanthine (caffeine metabolite, 0.08%, 0.12 μg/L), sulfamethoxazole (antibiotic, 0.41%, 0.17 μg/L), and trimethoprim (antibiotic, 0.08%, 0.018 μg/L). Detection frequencies of pesticides (33%), volatile organic compounds not including trihalomethanes (23%), and trihalomethanes (28%) in the same 1231 samples were significantly higher. Median detected concentration of pharmaceutical compounds was similar to those of volatile organic compounds, and higher than that of pesticides. Pharmaceutical compounds were detected in 3.3% of the 855 samples containing modern groundwater (tritium activity > 0.2 TU). Pharmaceutical detections were significantly positively correlated with detections of urban-use herbicides and insecticides, detections of volatile organic compounds, and percentage of urban land use around wells. Groundwater from the Los Angeles metropolitan area had higher detection frequencies of pharmaceuticals and other anthropogenic compounds than groundwater from other areas of the state with similar proportions of urban land use. The higher detection frequencies may reflect that groundwater flow systems in Los Angeles area basins are dominated by engineered recharge and intensive groundwater pumping.

  3. Development of Novel Piezoelectric Biosensor Using PZT Ceramic Resonator for Detection of Cancer Markers.

    PubMed

    Su, Li; Fong, Chi-Chun; Cheung, Pik-Yuan; Yang, Mengsu

    2017-01-01

    A novel biosensor based on piezoelectric ceramic resonator was developed for direct detection of cancer markers in the study. For the first time, a commercially available PZT ceramic resonator with high resonance frequency was utilized as transducer for a piezoelectric biosensor. A dual ceramic resonators scheme was designed wherein two ceramic resonators were connected in parallel: one resonator was used as the sensing unit and the other as the control unit. This arrangement minimizes environmental influences including temperature fluctuation, while achieving the required frequency stability for biosensing applications. The detection of the cancer markers Prostate Specific Antigen (PSA) and α-Fetoprotein (AFP) was carried out through frequency change measurement. The device showed high sensitivity (0.25 ng/ml) and fast detection (within 30 min) with small samples (1 μl), which is compatible with the requirements of clinical measurements. The results also showed that the ceramic resonator-based piezoelectric biosensor platform could be utilized with different chemical interfaces, and had the potential to be further developed into biosensor arrays with different specificities for simultaneous detection of multiple analytes.

  4. Modeling of an 8-12 GHz receiver front-end based on an in-line MEMS frequency discriminator

    NASA Astrophysics Data System (ADS)

    Chu, Chenlei; Liao, Xiaoping

    2018-06-01

    This paper focuses on the modeling of an 8-12 GHz RF (radio frequency) receiver front-end based on an in-line MEMS (microelectromechanical systems) frequency discriminator. Actually, the frequency detection is realized by measuring the output dc thermal voltage generated by the MEMS thermoelectric power sensor. Based on this thermal voltage, it has a great potential to tune the resonant frequency of the VCO (voltage controlled oscillator) in the RF receiver front-end application. The equivalent circuit model of the in-line frequency discriminator is established and the measurement verification is also implemented. Measurement and simulation results show that the output dc thermal voltage has a nearly linear relation with frequency. A new construction of RF receiver front-end is then obtained by connecting the in-line frequency discriminator with the voltage controlling port of VCO. Lastly, a systemic simulation is processed by computer-aided software and the real-time simulation waveform at each key point is observed clearly.

  5. Ayahuasca in adolescence: a preliminary psychiatric assessment.

    PubMed

    Da Silveira, Dartiu Xavier; Grob, Charles S; de Rios, Marlene Dobkin; Lopez, Enrique; Alonso, Luisa K; Tacla, Cristiane; Doering-Silveira, Evelyn

    2005-06-01

    Ayahuasca is believed to be harmless for those (including adolescents) drinking it within a religious setting. Nevertheless controlled studies on the mental/ psychiatric status of ritual hallucinogenic ayahuasca concoction consumers are still lacking. In this study, 40 adolescents from a Brazilian ayahuasca sect were compared with 40 controls matched on sex, age, and educational background for psychiatric symptomatology. Screening scales for depression, anxiety, alcohol consumption patterns (abuse), attentional problems, and body dysmorphic disorders were used. It was found that, compared to controls, considerable lower frequencies of positive scoring for anxiety, body dismorphism, and attentional problems were detected among ayahuasca-using adolescents despite overall similar psychopathological profiles displayed by both study groups. Low frequencies of psychiatric symptoms detected among adolescents consuming ayahuasca within a religious context may reflect a protective effect due to their religious affiliation. However further studies on the possible interference of other variables in the outcome are necessary.

  6. Single-shot detection and direct control of carrier phase drift of midinfrared pulses.

    PubMed

    Manzoni, Cristian; Först, Michael; Ehrke, Henri; Cavalleri, Andrea

    2010-03-01

    We introduce a scheme for single-shot detection and correction of the carrier-envelope phase (CEP) drift of femtosecond pulses at mid-IR wavelengths. Difference frequency mixing between the mid-IR field and a near-IR gate pulse generates a near-IR frequency-shifted pulse, which is then spectrally interfered with a replica of the gate pulse. The spectral interference pattern contains shot-to-shot information of the CEP of the mid-IR field, and it can be used for simultaneous correction of its slow drifts. We apply this technique to detect and compensate long-term phase drifts at 17 microm wavelength, reducing fluctuations to only 110 mrad over hours of operation.

  7. Acoustic Beam Forming Array Using Feedback-Controlled Microphones for Tuning and Self-Matching of Frequency Response

    NASA Technical Reports Server (NTRS)

    Radcliffe, Eliott (Inventor); Naguib, Ahmed (Inventor); Humphreys, Jr., William M. (Inventor)

    2014-01-01

    A feedback-controlled microphone includes a microphone body and a membrane operatively connected to the body. The membrane is configured to be initially deflected by acoustic pressure such that the initial deflection is characterized by a frequency response. The microphone also includes a sensor configured to detect the frequency response of the initial deflection and generate an output voltage indicative thereof. The microphone additionally includes a compensator in electric communication with the sensor and configured to establish a regulated voltage in response to the output voltage. Furthermore, the microphone includes an actuator in electric communication with the compensator, wherein the actuator is configured to secondarily deflect the membrane in opposition to the initial deflection such that the frequency response is adjusted. An acoustic beam forming microphone array including a plurality of the above feedback-controlled microphones is also disclosed.

  8. [Increased expressions of peripheral PD-1+ lymphocytes and CD4+CD25+FOXP3+ T cells in gastric adenocarcinoma patients].

    PubMed

    Li, Hao; Li, Songyan; Hu, Shidong; Zou, Guijun; Hu, Zilong; Wei, Huahua; Wang, Yufeng; Du, Xiaohui

    2017-01-01

    Objective To detect the frequencies of peripheral programmed death-1 + (PD-1 + ) lymphocytes and CD4 + CD25 + FOXP3 + regulatory T cells in patients with gastric adenocarcinoma. Methods The study enrolled 29 patients with gastric adenocarcinoma and 29 age- and sex-matched healthy controls. Frequencies of PD-1 + lymphocytes and CD4 + CD25 + FOXP3 + regulatory T cells were detected using flow cytometry. Results The number of PD-1 + lymphocytes and CD4 + CD25 + FOXP3 + regulatory T cells in peripheral blood was higher in patients with gastric adenocarcinoma than that in the control group. Moreover, linear correlation analysis indicated a positive correlation between PD-1 expression and frequency of CD4 + CD25 + FOXP3 + regulatory T cells in peripheral blood of the patients. Conclusion Gastric adenocarcinoma patients present with increased PD-1 + lymphocytes and CD4 + CD25 + FOXP3 + regulatory T cells in the peripheral blood.

  9. Testbed-based Performance Evaluation of Attack Resilient Control for AGC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashok, Aditya; Sridhar, Siddharth; McKinnon, Archibald D.

    The modern electric power grid is a complex cyber-physical system whose reliable operation is enabled by a wide-area monitoring and control infrastructure. This infrastructure, supported by an extensive communication backbone, enables several control applications functioning at multiple time scales to ensure the grid is maintained within stable operating limits. Recent events have shown that vulnerabilities in this infrastructure may be exploited to manipulate the data being exchanged. Such a scenario could cause the associated control application to mis-operate, potentially causing system-wide instabilities. There is a growing emphasis on looking beyond traditional cybersecurity solutions to mitigate such threats. In this papermore » we perform a testbed-based validation of one such solution - Attack Resilient Control (ARC) - on Iowa State University's \\textit{PowerCyber} testbed. ARC is a cyber-physical security solution that combines domain-specific anomaly detection and model-based mitigation to detect stealthy attacks on Automatic Generation Control (AGC). In this paper, we first describe the implementation architecture of the experiment on the testbed. Next, we demonstrate the capability of stealthy attack templates to cause forced under-frequency load shedding in a 3-area test system. We then validate the performance of ARC by measuring its ability to detect and mitigate these attacks. Our results reveal that ARC is efficient in detecting stealthy attacks and enables AGC to maintain system operating frequency close to its nominal value during an attack. Our studies also highlight the importance of testbed-based experimentation for evaluating the performance of cyber-physical security and control applications.« less

  10. Multichannel linear descriptors analysis for event-related EEG of vascular dementia patients during visual detection task.

    PubMed

    Lou, Wutao; Xu, Jin; Sheng, Hengsong; Zhao, Songzhen

    2011-11-01

    Multichannel EEG recorded in a task condition could contain more information about cognition. However, that has not been widely investigated in the vascular-dementia (VaD)- related studies. The purpose of this study was to explore the differences of brain functional states between VaD patients and normal controls while performing a detection task. Three multichannel linear descriptors, i.e. spatial complexity (Ω), field strength (Σ) and frequency of field changes (Φ), were applied to analyse four frequency bands (delta, theta, alpha and beta) of multichannel event-related EEG signals for 12 VaD patients (mean age ± SD: 69.25 ± 10.56 years ; MMSE score ± SD: 22.58 ± 4.42) and 12 age-matched healthy subjects (mean age ± SD: 67.17 ± 5.97 years ; MMSE score ± SD: 29.08 ± 0.9). The correlations between the three measures and MMSE scores were also analysed. VaD patients showed a significant higher Ω value in the delta (p = 0.013) and theta (p = 0.021) frequency bands, a lower Σ value (p = 0.011) and a higher Φ (p = 0.008) value in the delta frequency band compared with normal controls. The MMSE scores were negatively correlated with the Ω (r = -0.52, p = 0.01) and Φ (r = -0.47, p = 0.02) values in the delta frequency band. The results indicated the VaD patients presented a reduction of synchronization in the slow frequency band during target detection, and suggested more neurons might be activated in VaD patients compared with normal controls. The Ω and Φ measures in the delta frequency band might be used to evaluate the degree of cognitive dysfunction. The multichannel linear descriptors are promising measures to reveal the differences in brain functions between VaD patients and normal subjects, and could potentially be used to evaluate the degree of cognitive dysfunction in VaD patients. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Association of gene polymorphisms in ABO blood group chromosomal regions and menstrual disorders

    PubMed Central

    SU, YONG; KONG, GUI-LIAN; SU, YA-LI; ZHOU, YAN; LV, LI-FANG; WANG, QIONG; HUANG, BAO-PING; ZHENG, RUI-ZHI; LI, QUAN-ZHONG; YUAN, HUI-JUAN; ZHAO, ZHI-GANG

    2015-01-01

    This study aimed to investigate whether single nucleotide polymorphisms (SNPs) located near the gene of the ABO blood group play an important role in the genetic aetiology of menstrual disorders (MDs). Polymerase chain reaction-ligase detection reaction technology was used to detect eight SNPs near the ABO gene location on the chromosomes in 250 cases of MD and 250 cases of normal menstruation. The differences in the distribution of each genotype, as well as the allele frequency in the normal and control groups, were analysed using Pearson's χ2 test to search for disease-associated loci. SHEsis software was used to analyse the linkage disequilibrium and haplotype frequencies and to inspect the correlation between haplotypes and the disease. Compared with the control group, the experimental group exhibited statistically significant differences in the genotype distribution frequencies of the rs657152 locus of the ABO blood group gene and the rs17250673 locus of the tumour necrosis factor cofactor 2 (TRAF2) gene, which is located downstream of the ABO gene. The allele distribution frequencies of rs657152 and rs495828 loci in the ABO blood group gene exhibited significant differences between the groups. Dominant and recessive genetic model analysis of each locus revealed that the experimental group exhibited statistically significant differences from the control group in the genotype distribution frequencies of rs657152 and rs495828 loci, respectively. These results indicate that the ABO blood group gene and TRAF2 gene may be a cause of MDs. PMID:26136981

  12. Autonomous Decentralized Control of Supply and Demand by Inverter Based Distributed Generations in Isolated Microgrid

    NASA Astrophysics Data System (ADS)

    Shiki, Akira; Yokoyama, Akihiko; Baba, Jyunpei; Takano, Tomihiro; Gouda, Takahiro; Izui, Yoshio

    Recently, because of the environmental burden mitigation, energy conservations, energy security, and cost reductions, distributed generations are attracting our strong attention. These distributed generations (DGs) have been already installed to the distribution system, and much more DGs will be expected to be connected in the future. On the other hand, a new concept called “Microgrid” which is a small power supply network consisting of only DGs was proposed and some prototype projects are ongoing in Japan. The purpose of this paper is to develop the three-phase instantaneous valued digital simulator of microgrid consisting of a lot of inverter based DGs and to develop a supply and demand control method in isolated microgrid. First, microgrid is modeled using MATLAB/SIMULINK. We develop models of three-phase instantaneous valued inverter type CVCF generator, PQ specified generator, PV specified generator, PQ specified load as storage battery, photovoltaic generation, fuel cell and inverter load respectively. Then we propose an autonomous decentralized control method of supply and demand in isolated microgrid where storage batteries, fuel cells, photovoltaic generations and loads are connected. It is proposed here that the system frequency is used as a means to control DG output. By changing the frequency of the storage battery due to unbalance of supply and demand, all inverter based DGs detect the frequency fluctuation and change their own outputs. Finally, a new frequency control method in autonomous decentralized control of supply and demand is proposed. Though the frequency is used to transmit the information on the supply and demand unbalance to DGs, after the frequency plays the role, the frequency finally has to return to a standard value. To return the frequency to the standard value, the characteristic curve of the fuel cell is shifted in parallel. This control is carried out corresponding to the fluctuation of the load. The simulation shows that the frequency can be controlled well and has been made clear the effectiveness of the frequency control system.

  13. System and method for quench protection of a superconductor

    DOEpatents

    Huang, Xianrui; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas

    2008-03-11

    A system and method for protecting a superconductor from a quench condition. A quench protection system is provided to protect the superconductor from damage due to a quench condition. The quench protection system comprises a voltage detector operable to detect voltage across the superconductor. The system also comprises a frequency filter coupled to the voltage detector. The frequency filter is operable to couple voltage signals to a control circuit that are representative of a rise in superconductor voltage caused by a quench condition and to block voltage signals that are not. The system is operable to detect whether a quench condition exists in the superconductor based on the voltage signal received via the frequency filter and to initiate a protective action in response.

  14. Hydrogeology from 10,000 ft below: lessons learned in applying pulse testing for leakage detection in a carbon sequestration formation

    NASA Astrophysics Data System (ADS)

    Sun, A. Y.; Lu, J.; Hovorka, S. D.; Freifeld, B. M.; Islam, A.

    2015-12-01

    Monitoring techniques capable of deep subsurface detection are desirable for early warning and leakage pathway identification in geologic carbon storage formations. This work investigates the feasibility of a leakage detection technique based on pulse testing, which is a traditional hydrogeological characterization tool. In pulse testing, the monitoring reservoir is stimulated at a fixed frequency and the acquired pressure perturbation signals are analyzed in the frequency domain to detect potential deviations in the reservoir's frequency domain response function. Unlike traditional time-domain analyses, the frequency-domain analysis aims to minimize the interference of reservoir noise by imposing coded injection patterns such that the reservoir responses to injection can be uniquely determined. We have established the theoretical basis of the approach in previous work. Recently, field validation of this pressure-based, leakage detection technique was conducted at a CO2-EOR site located in Mississippi, USA. During the demonstration, two sets of experiments were performed using 90-min and 150-min pulsing periods, for both with and without leak scenarios. Because of the lack of pre-existing leakage pathways, artificial leakage CO2 was simulated by rate-controlled venting from one of the monitoring wells. Our results show that leakage events caused a significant deviation in the amplitude of the frequency response function, indicating that pulse testing may be used as a cost-effective monitoring technique with a strong potential for automation.

  15. Eddy Current System and Method for Crack Detection

    NASA Technical Reports Server (NTRS)

    Wincheski, Russell A. (Inventor); Simpson, John W. (Inventor)

    2012-01-01

    An eddy current system and method enables detection of sub-surface damage in a cylindrical object. The invention incorporates a dual frequency, orthogonally wound eddy current probe mounted on a stepper motor-controlled scanning system. The system is designed to inspect for outer surface damage from the interior of the cylindrical object.

  16. Acoustic detection of pneumothorax

    NASA Astrophysics Data System (ADS)

    Mansy, Hansen A.; Royston, Thomas J.; Balk, Robert A.; Sandler, Richard H.

    2003-04-01

    This study aims at investigating the feasibility of using low-frequency (<2000 Hz) acoustic methods for medical diagnosis. Several candidate methods of pneumothorax detection were tested in dogs. In the first approach, broadband acoustic signals were introduced into the trachea during end-expiration and transmitted waves were measured at the chest surface. Pneumothorax was found to consistently decrease pulmonary acoustic transmission in the 200-1200-Hz frequency band, while less change was observed at lower frequencies (p<0.0001). The ratio of acoustic energy between low (<220 Hz) and mid (550-770 Hz) frequency bands was significantly different in the control (healthy) and pneumothorax states (p<0.0001). The second approach measured breath sounds in the absence of an external acoustic input. Pneumothorax was found to be associated with a preferential reduction of sound amplitude in the 200- to 700-Hz range, and a decrease of sound amplitude variation (in the 300 to 600-Hz band) during the respiration cycle (p<0.01 for each). Finally, chest percussion was implemented. Pneumothorax changed the frequency and decay rate of percussive sounds. These results imply that certain medical conditions may be reliably detected using appropriate acoustic measurements and analysis. [Work supported by NIH/NHLBI #R44HL61108.

  17. Fractal Analysis and Hurst Parameter for Intrapartum Fetal Heart Rate Variability Analysis: A Versatile Alternative to Frequency Bands and LF/HF Ratio

    PubMed Central

    Doret, Muriel; Spilka, Jiří; Chudáček, Václav; Gonçalves, Paulo; Abry, Patrice

    2015-01-01

    Background The fetal heart rate (FHR) is commonly monitored during labor to detect early fetal acidosis. FHR variability is traditionally investigated using Fourier transform, often with adult predefined frequency band powers and the corresponding LF/HF ratio. However, fetal conditions differ from adults and modify spectrum repartition along frequencies. Aims This study questions the arbitrariness definition and relevance of the frequency band splitting procedure, and thus of the calculation of the underlying LF/HF ratio, as efficient tools for characterizing intrapartum FHR variability. Study Design The last 30 minutes before delivery of the intrapartum FHR were analyzed. Subjects Case-control study. A total of 45 singletons divided into two groups based on umbilical cord arterial pH: the Index group with pH ≤ 7.05 (n = 15) and Control group with pH > 7.05 (n = 30). Outcome Measures Frequency band-based LF/HF ratio and Hurst parameter. Results This study shows that the intrapartum FHR is characterized by fractal temporal dynamics and promotes the Hurst parameter as a potential marker of fetal acidosis. This parameter preserves the intuition of a power frequency balance, while avoiding the frequency band splitting procedure and thus the arbitrary choice of a frequency separating bands. The study also shows that extending the frequency range covered by the adult-based bands to higher and lower frequencies permits the Hurst parameter to achieve better performance for identifying fetal acidosis. Conclusions The Hurst parameter provides a robust and versatile tool for quantifying FHR variability, yields better acidosis detection performance compared to the LF/HF ratio, and avoids arbitrariness in spectral band splitting and definitions. PMID:26322889

  18. [Alcoholism during pregnancy: an underestimated health problem].

    PubMed

    Montesinos Balboa, Jorge Eduardo; Altúzar González, Marlene; Benítez Castillejos, Fortunato

    2004-10-01

    To identify the frequency of consumption of alcohol in pregnant women who went to a module of prenatal control; to describe the consumption habits and to identify the number of cases in those that the physician of first level identified the addiction, using the institutional instruments. A descriptive and prospective study was carried out, the study population was selected by means of non randomized sampling of the total of pregnant women who went to receive services of prenatal control, in two units of family medicine of the Mexican Institute of Social Security, of Tapachula, Chiapas, Mexico. The instrument AUDIT (Alcoholism Disorders Identification Test) was used, to identify use-frequency, abuse, dependence and physical/mental damage conditioned by the alcohol. In 132 studied women, it found a frequency of 45.5% of pregnant women with positive consumption and a case of dependence, none of which was identified by the family doctor. The consumption of alcohol in the studied population is high, even bigger than the frequency detected in populations of non pregnant women. The use of detection tests such as the AUDIT and the implementation of measures guided to the training and the personnel's of health sensitization about the magnitude and impact of this problem are recommended.

  19. Detection of micronuclei formation and nuclear anomalies in regenerative nodules of human cirrhotic livers and relationship to hepatocellular carcinoma.

    PubMed

    de Almeida, Terezinha M B; Leitão, Regina C; Andrade, Joyce D; Beçak, Willy; Carrilho, Flair J; Sonohara, Shigueko

    2004-04-01

    Human cirrhosis is considered an important factor in hepatocarcinogenesis. The lack of substantial genetics and cytogenetics data in human cirrhosis led us to investigate spontaneous micronuclei formation, as an indicator of chromosomal damage. The analysis was performed in hepatocytes of regenerative, macroregenerative, and tumoral nodules from 30 cases of cirrhosis (paraffin-embedded archival material), retrospectively selected: cryptogenic, hepatitis C virus, and hepatitis C virus associated with hepatocellular carcinoma (HCC). Thirteen control liver samples of healthy organ donors were included. Micronucleated hepatocytes were analyzed with Feulgen-fast-green dyeing techniques. The spontaneous frequency of micronucleated hepatocytes in both regenerative and macroregenerative nodules of all cirrhotic patients was significantly higher than for the normal control group. There was no significant difference in frequency of micronucleated hepatocytes in regenerative nodules compared with macroregenerative nodules for all cases analyzed, whereas a significantly higher frequency of micronucleated hepatocytes was detected in tumoral nodules, compared with cirrhotic regenerative nodules and normal parenchyma. A higher frequency of the nuclear anomalies termed broken-eggs was observed in hepatitis C virus-related samples. Chromatinic losses and genotoxicity already existed in the cirrhotic regenerative nodules, which might predispose to development of HCC.

  20. Intrinsic biocontainment: Multiplex genome safeguards combine transcriptional and recombinational control of essential yeast genes

    PubMed Central

    Cai, Yizhi; Agmon, Neta; Choi, Woo Jin; Ubide, Alba; Stracquadanio, Giovanni; Caravelli, Katrina; Hao, Haiping; Bader, Joel S.; Boeke, Jef D.

    2015-01-01

    Biocontainment may be required in a wide variety of situations such as work with pathogens, field release applications of engineered organisms, and protection of intellectual properties. Here, we describe the control of growth of the brewer’s yeast, Saccharomyces cerevisiae, using both transcriptional and recombinational “safeguard” control of essential gene function. Practical biocontainment strategies dependent on the presence of small molecules require them to be active at very low concentrations, rendering them inexpensive and difficult to detect. Histone genes were controlled by an inducible promoter and controlled by 30 nM estradiol. The stability of the engineered genes was separately regulated by the expression of a site-specific recombinase. The combined frequency of generating viable derivatives when both systems were active was below detection (<10−10), consistent with their orthogonal nature and the individual escape frequencies of <10−6. Evaluation of escaper mutants suggests strategies for reducing their emergence. Transcript profiling and growth test suggest high fitness of safeguarded strains, an important characteristic for wide acceptance. PMID:25624482

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beker, M. G., E-mail: M.Beker@Nikhef.nl; Bertolini, A.; Hennes, E.

    There is a strong scientific case for the study of gravitational waves at or below the lower end of current detection bands. To take advantage of this scientific benefit, future generations of ground based gravitational wave detectors will need to expand the limit of their detection bands towards lower frequencies. Seismic motion presents a major challenge at these frequencies and vibration isolation systems will play a crucial role in achieving the desired low-frequency sensitivity. A compact vibration isolation system designed to isolate in-vacuum optical benches for Advanced Virgo will be introduced and measurements on this system are used to presentmore » its performance. All high performance isolation systems employ an active feedback control system to reduce the residual motion of their suspended payloads. The development of novel control schemes is needed to improve the performance beyond what is currently feasible. Here, we present a multi-channel feedback approach that is novel to the field. It utilizes a linear quadratic regulator in combination with a Kalman state observer and is shown to provide effective suppression of residual motion of the suspended payload. The application of state observer based feedback control for vibration isolation will be demonstrated with measurement results from the Advanced Virgo optical bench suspension system.« less

  2. High sensitivity real-time NVR monitor

    NASA Technical Reports Server (NTRS)

    Bowers, William D. (Inventor); Chuan, Raymond L. (Inventor)

    1997-01-01

    A real time non-volatile residue (NVR) monitor, which utilizes surface acoustic wave (SAW) resonators to detect molecular contamination in a given environment. The SAW resonators operate at a resonant frequency of approximately 200 MHz-2,000 MHz which enables the NVR monitor to detect molecular contamination on the order of 10.sup.-11 g-cm.sup.-2 to 10.sup.-13 g-cm.sup.2. The NVR monitor utilizes active temperature control of (SAW) resonators to achieve a stable resonant frequency. The temperature control system of the NVR monitor is able to directly heat and cool the SAW resonators utilizing a thermoelectric element to maintain the resonators at a present temperature independent of the environmental conditions. In order to enable the direct heating and cooling of the SAW resonators, the SAW resonators are operatively mounted to a heat sink. In one embodiment, the heat sink is located in between the SAW resonators and an electronic circuit board which contains at least a portion of the SAW control electronics. The electrical leads of the SAW resonators are connected through the heat sink to the circuit board via an electronic path which prevents inaccurate frequency measurement.

  3. Algorithms for the detection of chewing behavior in dietary monitoring applications

    NASA Astrophysics Data System (ADS)

    Schmalz, Mark S.; Helal, Abdelsalam; Mendez-Vasquez, Andres

    2009-08-01

    The detection of food consumption is key to the implementation of successful behavior modification in support of dietary monitoring and therapy, for example, during the course of controlling obesity, diabetes, or cardiovascular disease. Since the vast majority of humans consume food via mastication (chewing), we have designed an algorithm that automatically detects chewing behaviors in surveillance video of a person eating. Our algorithm first detects the mouth region, then computes the spatiotemporal frequency spectrum of a small perioral region (including the mouth). Spectral data are analyzed to determine the presence of periodic motion that characterizes chewing. A classifier is then applied to discriminate different types of chewing behaviors. Our algorithm was tested on seven volunteers, whose behaviors included chewing with mouth open, chewing with mouth closed, talking, static face presentation (control case), and moving face presentation. Early test results show that the chewing behaviors induce a temporal frequency peak at 0.5Hz to 2.5Hz, which is readily detected using a distance-based classifier. Computational cost is analyzed for implementation on embedded processing nodes, for example, in a healthcare sensor network. Complexity analysis emphasizes the relationship between the work and space estimates of the algorithm, and its estimated error. It is shown that chewing detection is possible within a computationally efficient, accurate, and subject-independent framework.

  4. Apparatus and method for microwave processing of materials

    DOEpatents

    Johnson, A.C.; Lauf, R.J.; Bible, D.W.; Markunas, R.J.

    1996-05-28

    Disclosed is a variable frequency microwave heating apparatus designed to allow modulation of the frequency of the microwaves introduced into a furnace cavity for testing or other selected applications. The variable frequency heating apparatus is used in the method of the present invention to monitor the resonant processing frequency within the furnace cavity depending upon the material, including the state thereof, from which the workpiece is fabricated. The variable frequency microwave heating apparatus includes a microwave signal generator and a high-power microwave amplifier or a microwave voltage-controlled oscillator. A power supply is provided for operation of the high-power microwave oscillator or microwave amplifier. A directional coupler is provided for detecting the direction and amplitude of signals incident upon and reflected from the microwave cavity. A first power meter is provided for measuring the power delivered to the microwave furnace. A second power meter detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load. 10 figs.

  5. Femtosecond Chirp-Free Transient Absorption Method And Apparatus

    DOEpatents

    McBranch, Duncan W.; Klimov, Victor I.

    2001-02-20

    A method and apparatus for femtosecond transient absorption comprising phase-sensitive detection, spectral scanning and simultaneous controlling of a translation stage to obtain TA spectra information having at least a sensitivity two orders of magnitude higher than that for single-shot methods, with direct, simultaneous compensation for chirp as the data is acquired. The present invention includes a amplified delay translation stage which generates a splittable frequency-doubled laser signal at a predetermined frequency f, a controllable means for synchronously modulating one of the laser signals at a repetition rate of f/2, applying the laser signals to a material to be sample, and acquiring data from the excited sample while simultaneously controlling the controllable means for synchronously modulating.

  6. A diode laser-based velocimeter providing point measurements in unseeded flows using modulated filtered Rayleigh scattering (MFRS)

    NASA Astrophysics Data System (ADS)

    Jagodzinski, Jeremy James

    2007-12-01

    The development to date of a diode-laser based velocimeter providing point-velocity-measurements in unseeded flows using molecular Rayleigh scattering is discussed. The velocimeter is based on modulated filtered Rayleigh scattering (MFRS), a novel variation of filtered Rayleigh scattering (FRS), utilizing modulated absorption spectroscopy techniques to detect a strong absorption of a relatively weak Rayleigh scattered signal. A rubidium (Rb) vapor filter is used to provide the relatively strong absorption; alkali metal vapors have a high optical depth at modest vapor pressures, and their narrow linewidth is ideally suited for high-resolution velocimetry. Semiconductor diode lasers are used to generate the relatively weak Rayleigh scattered signal; due to their compact, rugged construction diode lasers are ideally suited for the environmental extremes encountered in many experiments. The MFRS technique utilizes the frequency-tuning capability of diode lasers to implement a homodyne detection scheme using lock-in amplifiers. The optical frequency of the diode-based laser system used to interrogate the flow is rapidly modulated about a reference frequency in the D2-line of Rb. The frequency modulation is imposed on the Rayleigh scattered light that is collected from the probe volume in the flow under investigation. The collected frequency modulating Rayleigh scattered light is transmitted through a Rb vapor filter before being detected. The detected modulated absorption signal is fed to two lock-in amplifers synchronized with the modulation frequency of the source laser. High levels of background rejection are attained since the lock-ins are both frequency and phase selective. The two lock-in amplifiers extract different Fourier components of the detected modulated absorption signal, which are ratioed to provide an intensity normalized frequency dependent signal from a single detector. A Doppler frequency shift in the collected Rayleigh scattered light due to a change in the velocity of the flow under investigation results in a change in the detected modulated absorption signal. This change in the detected signal provides a quantifiable measure of the Doppler frequency shift, and hence the velocity in the probe volume, provided that the laser source exhibits acceptable levels of frequency stability (determined by the magnitude of the velocities being measured). An extended cavity diode laser (ECDL) in the Littrow configuration provides frequency tunable, relatively narrow-linewidth lasing for the MFRS velocimeter. Frequency stabilization of the ECDL is provided by a proportional-integral-differential (PID) controller based on an error signal in the reference arm of the experiment. The optical power of the Littrow laser source is amplified by an antireflection coated (AR coated) broad stripe diode laser. The single-mode, frequency-modulatable, frequency-stable O(50 mW) of optical power provided by this extended cavity diode laser master oscillator power amplifier (ECDL-MOPA) system provided sufficient scattering signal from a condensing jet of CO2 to implement the MFRS technique in the frequency-locked mode of operation.

  7. Coaxial cable Bragg grating assisted microwave coupler.

    PubMed

    Huang, Jie; Wei, Tao; Fan, Jun; Xiao, Hai

    2014-01-01

    This paper reports a microwave coupler based on two parallel coaxial cable Bragg gratings fabricated by drilling U-grooves across the cables at periodic distance along the cable direction. Electromagnetic field couplings between two cables were observed at discrete frequencies through both near and far ends detections. The coupling frequency and strength can be precisely controlled by varying the grating period and length. The coupling bandwidth may also be controlled through specific grating design. The device physics was also described through transfer matrix which matched well with the experimental results.

  8. TeraSCREEN: multi-frequency multi-mode Terahertz screening for border checks

    NASA Astrophysics Data System (ADS)

    Alexander, Naomi E.; Alderman, Byron; Allona, Fernando; Frijlink, Peter; Gonzalo, Ramón; Hägelen, Manfred; Ibáñez, Asier; Krozer, Viktor; Langford, Marian L.; Limiti, Ernesto; Platt, Duncan; Schikora, Marek; Wang, Hui; Weber, Marc Andree

    2014-06-01

    The challenge for any security screening system is to identify potentially harmful objects such as weapons and explosives concealed under clothing. Classical border and security checkpoints are no longer capable of fulfilling the demands of today's ever growing security requirements, especially with respect to the high throughput generally required which entails a high detection rate of threat material and a low false alarm rate. TeraSCREEN proposes to develop an innovative concept of multi-frequency multi-mode Terahertz and millimeter-wave detection with new automatic detection and classification functionalities. The system developed will demonstrate, at a live control point, the safe automatic detection and classification of objects concealed under clothing, whilst respecting privacy and increasing current throughput rates. This innovative screening system will combine multi-frequency, multi-mode images taken by passive and active subsystems which will scan the subjects and obtain complementary spatial and spectral information, thus allowing for automatic threat recognition. The TeraSCREEN project, which will run from 2013 to 2016, has received funding from the European Union's Seventh Framework Programme under the Security Call. This paper will describe the project objectives and approach.

  9. Visual signal detection in structured backgrounds. II. Effects of contrast gain control, background variations, and white noise

    NASA Technical Reports Server (NTRS)

    Eckstein, M. P.; Ahumada, A. J. Jr; Watson, A. B.

    1997-01-01

    Studies of visual detection of a signal superimposed on one of two identical backgrounds show performance degradation when the background has high contrast and is similar in spatial frequency and/or orientation to the signal. To account for this finding, models include a contrast gain control mechanism that pools activity across spatial frequency, orientation and space to inhibit (divisively) the response of the receptor sensitive to the signal. In tasks in which the observer has to detect a known signal added to one of M different backgrounds grounds due to added visual noise, the main sources of degradation are the stochastic noise in the image and the suboptimal visual processing. We investigate how these two sources of degradation (contrast gain control and variations in the background) interact in a task in which the signal is embedded in one of M locations in a complex spatially varying background (structured background). We use backgrounds extracted from patient digital medical images. To isolate effects of the fixed deterministic background (the contrast gain control) from the effects of the background variations, we conduct detection experiments with three different background conditions: (1) uniform background, (2) a repeated sample of structured background, and (3) different samples of structured background. Results show that human visual detection degrades from the uniform background condition to the repeated background condition and degrades even further in the different backgrounds condition. These results suggest that both the contrast gain control mechanism and the background random variations degrade human performance in detection of a signal in a complex, spatially varying background. A filter model and added white noise are used to generate estimates of sampling efficiencies, an equivalent internal noise, an equivalent contrast-gain-control-induced noise, and an equivalent noise due to the variations in the structured background.

  10. Performance of the unique-word-reverse-modulation type demodulator for mobile satellite communications

    NASA Technical Reports Server (NTRS)

    Dohi, Tomohiro; Nitta, Kazumasa; Ueda, Takashi

    1993-01-01

    This paper proposes a new type of coherent demodulator, the unique-word (UW)-reverse-modulation type demodulator, for burst signal controlled by voice operated transmitter (VOX) in mobile satellite communication channels. The demodulator has three individual circuits: a pre-detection signal combiner, a pre-detection UW detector, and a UW-reverse-modulation type demodulator. The pre-detection signal combiner combines signal sequences received by two antennas and improves bit energy-to-noise power density ratio (E(sub b)/N(sub 0)) 2.5 dB to yield 10(exp -3) average bit error rate (BER) when carrier power-to-multipath power ratio (CMR) is 15 dB. The pre-detection UW detector improves UW detection probability when the frequency offset is large. The UW-reverse-modulation type demodulator realizes a maximum pull-in frequency of 3.9 kHz, the pull-in time is 2.4 seconds and frequency error is less than 20 Hz. The performances of this demodulator are confirmed through computer simulations and its effect is clarified in real-time experiments at a bit rate of 16.8 kbps using a digital signal processor (DSP).

  11. No evidence for spectral jamming avoidance in echolocation behavior of foraging pipistrelle bats

    PubMed Central

    Götze, Simone; Koblitz, Jens C.; Denzinger, Annette; Schnitzler, Hans-Ulrich

    2016-01-01

    Frequency shifts in signals of bats flying near conspecifics have been interpreted as a spectral jamming avoidance response (JAR). However, several prerequisites supporting a JAR hypothesis have not been controlled for in previous studies. We recorded flight and echolocation behavior of foraging Pipistrellus pipistrellus while flying alone and with a conspecific and tested whether frequency changes were due to a spectral JAR with an increased frequency difference, or whether changes could be explained by other reactions. P. pipistrellus reacted to conspecifics with a reduction of sound duration and often also pulse interval, accompanied by an increase in terminal frequency. This reaction is typical of behavioral situations where targets of interest have captured the bat’s attention and initiated a more detailed exploration. All observed frequency changes were predicted by the attention reaction alone, and do not support the JAR hypothesis of increased frequency separation. Reaction distances of 1–11 m suggest that the attention response may be elicited either by detection of the conspecific by short range active echolocation or by long range passive acoustic detection of echolocation calls. PMID:27502900

  12. Recurrence plot analysis of nonstationary data: the understanding of curved patterns.

    PubMed

    Facchini, A; Kantz, H; Tiezzi, E

    2005-08-01

    Recurrence plots of the calls of the Nomascus concolor (Western black crested gibbon) and Hylobates lar (White-handed gibbon) show characteristic circular, curved, and hyperbolic patterns superimposed to the main temporal scale of the signal. It is shown that these patterns are related to particular nonstationarities in the signal. Some of them can be reproduced by artificial signals like frequency modulated sinusoids and sinusoids with time divergent frequency. These modulations are too faint to be resolved by conventional time-frequency analysis with similar precision. Therefore, recurrence plots act as a magnifying glass for the detection of multiple temporal scales in slightly modulated signals. The detected phenomena in these acoustic signals can be explained in the biomechanical context by taking in account the role of the muscles controlling the vocal folds.

  13. Seismic Characterizations of Fractures: Dynamic Diagnostics

    NASA Astrophysics Data System (ADS)

    Pyrak-Nolte, L. J.

    2017-12-01

    Fracture geometry controls fluid flow in a fracture, affects mechanical stability and influences energy partitioning that affects wave scattering. Our ability to detect and monitor fracture evolution is controlled by the frequency of the signal used to probe a fracture system, i.e. frequency selects the scales. No matter the frequency chosen, some set of discontinuities will be optimal for detection because different wavelengths sample different subsets of fractures. The select subset of fractures is based on the stiffness of the fractures which in turn is linked to fluid flow. A goal is obtaining information from scales outside the optimal detection regime. Fracture geometry trajectories are a potential approach to drive a fracture system across observation scales, i.e. moving systems between effective medium and scattering regimes. Dynamic trajectories (such as perturbing stress, fluid pressure, chemical alteration, etc.) can be used to perturb fracture geometry to enhance scattering or give rise to discrete modes that are intimately related to the micro-structural evolution of a fracture. However, identification of these signal features will require methods for identifying these micro-structural signatures in complicated scattered fields. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Geosciences Research Program under Award Number (DE-FG02-09ER16022).

  14. Radial-piston pump for drive of test machines

    NASA Astrophysics Data System (ADS)

    Nizhegorodov, A. I.; Gavrilin, A. N.; Moyzes, B. B.; Cherkasov, A. I.; Zharkevich, O. M.; Zhetessova, G. S.; Savelyeva, N. A.

    2018-01-01

    The article reviews the development of radial-piston pump with phase control and alternating-flow mode for seismic-testing platforms and other test machines. The prospects for use of the developed device are proved. It is noted that the method of frequency modulation with the detection of the natural frequencies is easily realized by using the radial-piston pump. The prospects of further research are given proof.

  15. Occurrence and concentrations of pharmaceutical compounds in groundwater used for public drinking-water supply in California.

    PubMed

    Fram, Miranda S; Belitz, Kenneth

    2011-08-15

    Pharmaceutical compounds were detected at low concentrations in 2.3% of 1231 samples of groundwater (median depth to top of screened interval in wells=61 m) used for public drinking-water supply in California. Samples were collected statewide for the California State Water Resources Control Board's Groundwater Ambient Monitoring and Assessment (GAMA) Program. Of 14 pharmaceutical compounds analyzed, 7 were detected at concentrations greater than or equal to method detection limits: acetaminophen (used as an analgesic, detection frequency 0.32%, maximum concentration 1.89 μg/L), caffeine (stimulant, 0.24%, 0.29 μg/L), carbamazepine (mood stabilizer, 1.5%, 0.42 μg/L), codeine (opioid analgesic, 0.16%, 0.214 μg/L), p-xanthine (caffeine metabolite, 0.08%, 0.12 μg/L), sulfamethoxazole (antibiotic, 0.41%, 0.17 μg/L), and trimethoprim (antibiotic, 0.08%, 0.018 μg/L). Detection frequencies of pesticides (33%), volatile organic compounds not including trihalomethanes (23%), and trihalomethanes (28%) in the same 1231 samples were significantly higher. Median detected concentration of pharmaceutical compounds was similar to those of volatile organic compounds, and higher than that of pesticides. Pharmaceutical compounds were detected in 3.3% of the 855 samples containing modern groundwater (tritium activity>0.2 TU). Pharmaceutical detections were significantly positively correlated with detections of urban-use herbicides and insecticides, detections of volatile organic compounds, and percentage of urban land use around wells. Groundwater from the Los Angeles metropolitan area had higher detection frequencies of pharmaceuticals and other anthropogenic compounds than groundwater from other areas of the state with similar proportions of urban land use. The higher detection frequencies may reflect that groundwater flow systems in Los Angeles area basins are dominated by engineered recharge and intensive groundwater pumping. Published by Elsevier B.V.

  16. Simultaneously measured signals in scanning probe microscopy with a needle sensor: frequency shift and tunneling current.

    PubMed

    Morawski, Ireneusz; Voigtländer, Bert

    2010-03-01

    We present combined noncontact scanning force microscopy and tunneling current images of a platinum(111) surface obtained by means of a 1 MHz quartz needle sensor. The low-frequency circuit of the tunneling current was combined with a high-frequency signal of the quartz resonator enabling full electrical operation of the sensor. The frequency shift and the tunneling current were detected simultaneously, while the feedback control loop of the topography signal was fed using one of them. In both cases, the free signal that was not connected to the feedback loop reveals proportional-integral controller errorlike behavior, which is governed by the time derivative of the topography signal. A procedure is proposed for determining the mechanical oscillation amplitude by utilizing the tunneling current also including the average tip-sample work function.

  17. Covert laser remote sensing and vibrometry

    NASA Technical Reports Server (NTRS)

    Maleki, Lutfollah (Inventor); Yu, Nan (Inventor); Matsko, Andrey B. (Inventor); Savchenkov, Anatoliy (Inventor)

    2012-01-01

    Designs of single-beam laser vibrometry systems and methods. For example, a method for detecting vibrations of a target based on optical sensing is provided to include operating a laser to produce a laser probe beam at a laser frequency and modulated at a modulation frequency onto a target; collecting light at or near the laser to collect light from the target while the target is being illuminated by the laser probe beam through an optical receiver aperture; using a narrow-band optical filter centered at the laser frequency to filter light collected from the optical receiver aperture to transmit light at the laser frequency while blocking light at other frequencies; using an optical detector to convert filtered light from the narrow-band optical filter to produce a receiver electrical signal; using a lock-in amplifier to detect and amplify the receiver electrical signal at the modulation frequency while rejecting signal components at other frequencies to produce an amplified receiver electrical signal; processing the amplified receiver electrical signal to extract information on vibrations of the target carried by reflected laser probe beam in the collected light; and controlling optical power of the laser probe beam at the target to follow optical power of background illumination at the target.

  18. The simple ears of noctuoid moths are tuned to the calls of their sympatric bat community.

    PubMed

    ter Hofstede, Hannah M; Goerlitz, Holger R; Ratcliffe, John M; Holderied, Marc W; Surlykke, Annemarie

    2013-11-01

    Insects with bat-detecting ears are ideal animals for investigating sensory system adaptations to predator cues. Noctuid moths have two auditory receptors (A1 and A2) sensitive to the ultrasonic echolocation calls of insectivorous bats. Larger moths are detected at greater distances by bats than smaller moths. Larger moths also have lower A1 best thresholds, allowing them to detect bats at greater distances and possibly compensating for their increased conspicuousness. Interestingly, the sound frequency at the lowest threshold is lower in larger than in smaller moths, suggesting that the relationship between threshold and size might vary across frequencies used by different bat species. Here, we demonstrate that the relationships between threshold and size in moths were only significant at some frequencies, and these frequencies differed between three locations (UK, Canada and Denmark). The relationships were more likely to be significant at call frequencies used by proportionately more bat species in the moths' specific bat community, suggesting an association between the tuning of moth ears and the cues provided by sympatric predators. Additionally, we found that the best threshold and best frequency of the less sensitive A2 receptor are also related to size, and that these relationships hold when controlling for evolutionary relationships. The slopes of best threshold versus size differ, however, such that the difference in threshold between A1 and A2 is greater for larger than for smaller moths. The shorter time from A1 to A2 excitation in smaller than in larger moths could potentially compensate for shorter absolute detection distances in smaller moths.

  19. Genetic Surveillance Detects Both Clonal and Epidemic Transmission of Malaria following Enhanced Intervention in Senegal

    PubMed Central

    Séne, Papa Diogoye; Park, Danny C.; Neafsey, Daniel E.; Schaffner, Stephen F.; Hamilton, Elizabeth J.; Lukens, Amanda K.; Van Tyne, Daria; Mboup, Souleymane; Sabeti, Pardis C.; Ndiaye, Daouda; Wirth, Dyann F.

    2013-01-01

    Using parasite genotyping tools, we screened patients with mild uncomplicated malaria seeking treatment at a clinic in Thiès, Senegal, from 2006 to 2011. We identified a growing frequency of infections caused by genetically identical parasite strains, coincident with increased deployment of malaria control interventions and decreased malaria deaths. Parasite genotypes in some cases persisted clonally across dry seasons. The increase in frequency of genetically identical parasite strains corresponded with decrease in the probability of multiple infections. Further, these observations support evidence of both clonal and epidemic population structures. These data provide the first evidence of a temporal correlation between the appearance of identical parasite types and increased malaria control efforts in Africa, which here included distribution of insecticide treated nets (ITNs), use of rapid diagnostic tests (RDTs) for malaria detection, and deployment of artemisinin combination therapy (ACT). Our results imply that genetic surveillance can be used to evaluate the effectiveness of disease control strategies and assist a rational global malaria eradication campaign. PMID:23593309

  20. Optical Control of Mechanical Mode-Coupling within a MoS2 Resonator in the Strong-Coupling Regime.

    PubMed

    Liu, Chang-Hua; Kim, In Soo; Lauhon, Lincoln J

    2015-10-14

    Two-dimensional (2-D) materials including graphene and transition metal dichalcogenides (TMDs) are an exciting platform for ultrasensitive force and displacement detection in which the strong light-matter coupling is exploited in the optical control of nanomechanical motion. Here we report the optical excitation and displacement detection of a ∼ 3 nm thick MoS2 resonator in the strong-coupling regime, which has not previously been achieved in 2-D materials. Mechanical mode frequencies can be tuned by more than 12% by optical heating, and they exhibit avoided crossings indicative of strong intermode coupling. When the membrane is optically excited at the frequency difference between vibrational modes, normal mode splitting is observed, and the intermode energy exchange rate exceeds the mode decay rate by a factor of 15. Finite element and analytical modeling quantifies the extent of mode softening necessary to control intermode energy exchange in the strong coupling regime.

  1. Psychophysical correspondence between vibrotactile intensity and intracortical microstimulation for tactile neuroprostheses in rats

    NASA Astrophysics Data System (ADS)

    Devecioğlu, İsmail; Güçlü, Burak

    2017-02-01

    Objective. Recent studies showed that intracortical microstimulation (ICMS) generates artificial sensations which can be utilized as somatosensory feedback in cortical neuroprostheses. To mimic the natural psychophysical response, ICMS parameters are modulated according to psychometric equivalence functions (PEFs). PEFs match the intensity levels of ICMS and mechanical stimuli, which elicit equal detection probabilities, but they typically do not include the frequency as a control variable. We aimed to establish frequency-dependent PEFs for vibrotactile stimulation of the glabrous skin and ICMS in the primary somatosensory cortex of awake freely behaving rats. Approach. We collected psychometric data for vibrotactile and ICMS detection at three stimulation frequencies (40, 60 and 80 Hz). The psychometric data were fitted with a model equation of two independent variables (stimulus intensity and frequency) and four subject-dependent parameters. For each rat, we constructed a separate PEF which was used to estimate the ICMS current amplitude for a given displacement amplitude and frequency. The ICMS frequency was set equal to the vibrotactile frequency. We validated the PEFs in a modified task which included randomly selected probe trials presented either with a vibrotactile or an ICMS stimulus, and also at frequencies and intensity levels not tested before. Main results. The PEFs were generally successful in estimating the ICMS current intensities (no significant differences between vibrotactile and ICMS trials in Kolmogorov-Smirnov tests). Specifically, hit rates from both trial conditions were significantly correlated in 86% of the cases, and 52% of all data had perfect match in linear regression. Significance. The psychometric correspondence model presented in this study was constructed based on surface functions which define psychophysical detection probability as a function of stimulus intensity and frequency. Therefore, it may be used for the real-time modulation of the frequency and intensity of ICMS pulses in somatosensory neuroprostheses.

  2. Psychophysical correspondence between vibrotactile intensity and intracortical microstimulation for tactile neuroprostheses in rats.

    PubMed

    Devecioğlu, İsmail; Güçlü, Burak

    2017-02-01

    Recent studies showed that intracortical microstimulation (ICMS) generates artificial sensations which can be utilized as somatosensory feedback in cortical neuroprostheses. To mimic the natural psychophysical response, ICMS parameters are modulated according to psychometric equivalence functions (PEFs). PEFs match the intensity levels of ICMS and mechanical stimuli, which elicit equal detection probabilities, but they typically do not include the frequency as a control variable. We aimed to establish frequency-dependent PEFs for vibrotactile stimulation of the glabrous skin and ICMS in the primary somatosensory cortex of awake freely behaving rats. We collected psychometric data for vibrotactile and ICMS detection at three stimulation frequencies (40, 60 and 80 Hz). The psychometric data were fitted with a model equation of two independent variables (stimulus intensity and frequency) and four subject-dependent parameters. For each rat, we constructed a separate PEF which was used to estimate the ICMS current amplitude for a given displacement amplitude and frequency. The ICMS frequency was set equal to the vibrotactile frequency. We validated the PEFs in a modified task which included randomly selected probe trials presented either with a vibrotactile or an ICMS stimulus, and also at frequencies and intensity levels not tested before. The PEFs were generally successful in estimating the ICMS current intensities (no significant differences between vibrotactile and ICMS trials in Kolmogorov-Smirnov tests). Specifically, hit rates from both trial conditions were significantly correlated in 86% of the cases, and 52% of all data had perfect match in linear regression. The psychometric correspondence model presented in this study was constructed based on surface functions which define psychophysical detection probability as a function of stimulus intensity and frequency. Therefore, it may be used for the real-time modulation of the frequency and intensity of ICMS pulses in somatosensory neuroprostheses.

  3. Gastrointestinal parasites in stray and shelter cats in the municipality of Rio de Janeiro, Brazil.

    PubMed

    Pereira, Pâmela Figueiredo; Barbosa, Alynne da Silva; Moura, Ana Paula Pereira de; Vasconcellos, Marcelo Leitão; Uchôa, Claudia Maria Antunes; Bastos, Otílio Machado Pereira; Amendoeira, Maria Regina Reis

    2017-01-01

    The increasingly urban nature of the population has led many people to choose independent pets, such as cats. This situation has also made it possible for these animals to be abandoned, thus increasing the numbers of cats on the streets and in shelters. These animals can act as a source of infection for other hosts. Between 2014 and 2015, the frequency of gastrointestinal parasites in captive and stray cats in the municipality of Rio de Janeiro was analyzed. Ninety-one fecal samples were collected from captive cats and 172 from stray cats. Centrifugal sedimentation and flotation techniques were used. The frequency of parasites among the stray cats was 77.3%, and this was significantly higher than the frequency observed in captive cats (49.5%). Helminths were detected more frequently, and hookworms were the parasites most detected. Toxocara cati, Cystoisospora sp. and Dipylidium caninum were also detected. No statistical difference in the frequency of parasites was observed between the sexes among the captive cats. However, among the stray cats, males (85.5%) presented higher positivity than females (71.8%). The high frequency of hookworms, which are the agent for "cutaneous larva migrans" in humans, shows the need to control parasitic infections among the cats studied.

  4. Modulation-format-free and automatic bias control for optical IQ modulators based on dither-correlation detection.

    PubMed

    Li, Xiaolei; Deng, Lei; Chen, Xiaoman; Cheng, Mengfan; Fu, Songnian; Tang, Ming; Liu, Deming

    2017-04-17

    A novel automatic bias control (ABC) method for optical in-phase and quadrature (IQ) modulator is proposed and experimentally demonstrated. In the proposed method, two different low frequency sine wave dither signals are generated and added on to the I/Q bias signal respectively. Instead of power monitoring of the harmonics of the dither signal, dither-correlation detection is proposed and used to adjust the bias voltages of the optical IQ modulator. By this way, not only frequency spectral analysis isn't required but also the directional bias adjustment could be realized, resulting in the decrease of algorithm complexity and the growth of convergence rate of ABC algorithm. The results show that the sensitivity of the proposed ABC method outperforms that of the traditional dither frequency monitoring method. Moreover, the proposed ABC method is proved to be modulation-format-free, and the transmission penalty caused by this method for both 10 Gb/s optical QPSK and 17.9 Gb/s optical 16QAM-OFDM signal transmission are negligible in our experiment.

  5. Sister chromatid exchanges and micronuclei analysis in lymphocytes of men exposed to simazine through drinking water.

    PubMed

    Suárez, Susanna; Rubio, Arantxa; Sueiro, Rosa Ana; Garrido, Joaquín

    2003-06-06

    In some cities of the autonomous community of Extremadura (south-west of Spain), levels of simazine from 10 to 30 ppm were detected in tap water. To analyse the possible effect of this herbicide, two biomarkers, sister chromatid exchanges (SCE) and micronuclei (MN), were used in peripheral blood lymphocytes from males exposed to simazine through drinking water. SCE and MN analysis failed to detect any statistically significant increase in the people exposed to simazine when compared with the controls. With respect to high frequency cells (HFC), a statistically significant difference was detected between exposed and control groups.

  6. Radio frequency detection assembly and method for detecting radio frequencies

    DOEpatents

    Cown, Steven H.; Derr, Kurt Warren

    2010-03-16

    A radio frequency detection assembly is described and which includes a radio frequency detector which detects a radio frequency emission produced by a radio frequency emitter from a given location which is remote relative to the radio frequency detector; a location assembly electrically coupled with the radio frequency detector and which is operable to estimate the location of the radio frequency emitter from the radio frequency emission which has been received; and a radio frequency transmitter electrically coupled with the radio frequency detector and the location assembly, and which transmits a radio frequency signal which reports the presence of the radio frequency emitter.

  7. Sample size requirements for indirect association studies of gene-environment interactions (G x E).

    PubMed

    Hein, Rebecca; Beckmann, Lars; Chang-Claude, Jenny

    2008-04-01

    Association studies accounting for gene-environment interactions (G x E) may be useful for detecting genetic effects. Although current technology enables very dense marker spacing in genetic association studies, the true disease variants may not be genotyped. Thus, causal genes are searched for by indirect association using genetic markers in linkage disequilibrium (LD) with the true disease variants. Sample sizes needed to detect G x E effects in indirect case-control association studies depend on the true genetic main effects, disease allele frequencies, whether marker and disease allele frequencies match, LD between loci, main effects and prevalence of environmental exposures, and the magnitude of interactions. We explored variables influencing sample sizes needed to detect G x E, compared these sample sizes with those required to detect genetic marginal effects, and provide an algorithm for power and sample size estimations. Required sample sizes may be heavily inflated if LD between marker and disease loci decreases. More than 10,000 case-control pairs may be required to detect G x E. However, given weak true genetic main effects, moderate prevalence of environmental exposures, as well as strong interactions, G x E effects may be detected with smaller sample sizes than those needed for the detection of genetic marginal effects. Moreover, in this scenario, rare disease variants may only be detectable when G x E is included in the analyses. Thus, the analysis of G x E appears to be an attractive option for the detection of weak genetic main effects of rare variants that may not be detectable in the analysis of genetic marginal effects only.

  8. Data acquisition and processing system and method for investigating sub-surface features of a rock formation

    DOEpatents

    Vu, Cung Khac; Nihei, Kurt; Johnson, Paul A; Guyer, Robert; Ten Cate, James A; Le Bas, Pierre-Yves; Larmat, Carene S

    2015-01-27

    A system and a method includes generating a first signal at a first frequency; and a second signal at a second frequency. Respective sources are positioned within the borehole and controllable such that the signals intersect in an intersection volume outside the borehole. A receiver detects a difference signal returning to the borehole generated by a non-linear mixing process within the intersection volume, and records the detected signal and stores the detected signal in a storage device and records measurement parameters including a position of the first acoustic source, a position of the second acoustic source, a position of the receiver, elevation angle and azimuth angle of the first acoustic signal and elevation angle and azimuth angle of the second acoustic signal.

  9. The Flashlight Fish Anomalops katoptron Uses Bioluminescent Light to Detect Prey in the Dark

    PubMed Central

    Hellinger, Jens; Jägers, Peter; Donner, Marcel; Sutt, Franziska; Mark, Melanie D.; Senen, Budiono; Tollrian, Ralph

    2017-01-01

    Bioluminescence is a fascinating phenomenon occurring in numerous animal taxa in the ocean. The reef dwelling splitfin flashlight fish (Anomalops katoptron) can be found in large schools during moonless nights in the shallow water of coral reefs and in the open surrounding water. Anomalops katoptron produce striking blink patterns with symbiotic bacteria in their sub-ocular light organs. We examined the blink frequency in A. katoptron under various laboratory conditions. During the night A. katoptron swims in schools roughly parallel to their conspecifics and display high blink frequencies of approximately 90 blinks/minute with equal on and off times. However, when planktonic prey was detected in the experimental tank, the open time increased compared to open times in the absence of prey and the frequency decreased to 20% compared to blink frequency at night in the absence of planktonic prey. During the day when the school is in a cave in the reef tank the blink frequency decreases to approximately 9 blinks/minute with increasing off-times of the light organ. Surprisingly the non-luminescent A. katoptron with non-functional light organs displayed the same blink frequencies and light organ open/closed times during the night and day as their luminescent conspecifics. In the presence of plankton non-luminescent specimens showed no change in the blink frequency and open/closed times compared to luminescent A. katoptron. Our experiments performed in a coral reef tank show that A. katoptron use bioluminescent illumination to detect planktonic prey and that the blink frequency of A. katoptron light organs follow an exogenous control by the ambient light. PMID:28178297

  10. Level of Automation and Failure Frequency Effects on Simulated Lunar Lander Performance

    NASA Technical Reports Server (NTRS)

    Marquez, Jessica J.; Ramirez, Margarita

    2014-01-01

    A human-in-the-loop experiment was conducted at the NASA Ames Research Center Vertical Motion Simulator, where instrument-rated pilots completed a simulated terminal descent phase of a lunar landing. Ten pilots participated in a 2 x 2 mixed design experiment, with level of automation as the within-subjects factor and failure frequency as the between subjects factor. The two evaluated levels of automation were high (fully automated landing) and low (manual controlled landing). During test trials, participants were exposed to either a high number of failures (75% failure frequency) or low number of failures (25% failure frequency). In order to investigate the pilots' sensitivity to changes in levels of automation and failure frequency, the dependent measure selected for this experiment was accuracy of failure diagnosis, from which D Prime and Decision Criterion were derived. For each of the dependent measures, no significant difference was found for level of automation and no significant interaction was detected between level of automation and failure frequency. A significant effect was identified for failure frequency suggesting failure frequency has a significant effect on pilots' sensitivity to failure detection and diagnosis. Participants were more likely to correctly identify and diagnose failures if they experienced the higher levels of failures, regardless of level of automation

  11. Detection of Neutrinos from Galactic and Cosmic Supernovae

    NASA Astrophysics Data System (ADS)

    Beacom, John

    2010-11-01

    Detecting neutrinos is the key to understanding core-collapse supernovae, but this is notoriously difficult due to the small interaction cross section of neutrinos and the low frequency of supernovae. The prospects for detecting Galactic supernovae depend almost completely on the probability of a fluctuation from the low supernova rate; the detection aspects are largely under control. The prospects for detecting Cosmic supernovae instead depend almost completely on the detection aspects, especially regarding reducing detector backgrounds; the supernova rate and neutrino flux of the universe are now rather well measured or predicted. After decades of effort and patience, we have good reasons to anticipate that detecting supernova neutrinos is within reach.

  12. {open_quotes}Horizontal{close_quotes} gene transfer from a transgenic potato line to a bacterial pathogen (Erwinia chrysanthemi) occurs - if at all - at an extremely low frequency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlueter, K.; Fuetterer, J.; Potrykus, I.

    1995-10-01

    The frequency of possible {open_quotes}horizontal{close_quotes} gene transfer between a plant and a tightly associated bacterial pathogen was studied in a model system consisting of transgenic Solanum tuberosum, containing a {beta}-lactamase gene linked to a pBR322 origin of replication, and Erwinia chrysanthemi. This experimental system offers optimal conditions for the detection of possible horizontal gene transfer events, even when they occur at very low frequency. Horizontal gene transfer was not detected under conditions mimicking a {open_quotes}natural{close_quotes} infection. The gradual, stepwise alteration of artificial, positive control conditions to idealized natural conditions, however, allowed the characterization of factors that affected gene transfer, andmore » revealed a gradual decrease of the gene transfer frequency from 6.3 x 10{sup -2} under optimal control conditions to a calculated 2.0 x 10{sub -17} under idealized natural conditions. These data, in combination with other published studies, argue that horizontal gene transfer is so rare as to be essentially irrelevant to any realistic assessment of the risk involved in release experiments involving transgenic plants. 22 refs., 3 figs., 2 tabs.« less

  13. Wireless Low-Power Integrated Basal-Body-Temperature Detection Systems Using Teeth Antennas in the MedRadio Band.

    PubMed

    Yang, Chin-Lung; Zheng, Gou-Tsun

    2015-11-20

    This study proposes using wireless low power thermal sensors for basal-body-temperature detection using frequency modulated telemetry devices. A long-term monitoring sensor requires low-power circuits including a sampling circuit and oscillator. Moreover, temperature compensated technologies are necessary because the modulated frequency might have additional frequency deviations caused by the varying temperature. The temperature compensated oscillator is composed of a ring oscillator and a controlled-steering current source with temperature compensation, so the output frequency of the oscillator does not drift with temperature variations. The chip is fabricated in a standard Taiwan Semiconductor Manufacturing Company (TSMC) 0.18-μm complementary metal oxide semiconductor (CMOS) process, and the chip area is 0.9 mm². The power consumption of the sampling amplifier is 128 µW. The power consumption of the voltage controlled oscillator (VCO) core is less than 40 µW, and the output is -3.04 dBm with a buffer stage. The output voltage of the bandgap reference circuit is 1 V. For temperature measurements, the maximum error is 0.18 °C with a standard deviation of ±0.061 °C, which is superior to the required specification of 0.1 °C.

  14. Longitudinal Detection and Persistence of Minority Drug-Resistant Populations and Their Effect on Salvage Therapy

    PubMed Central

    Nishizawa, Masako; Matsuda, Masakazu; Hattori, Junko; Shiino, Teiichiro; Matano, Tetsuro; Heneine, Walid; Johnson, Jeffrey A.; Sugiura, Wataru

    2015-01-01

    Background Drug-resistant HIV are more prevalent and persist longer than previously demonstrated by bulk sequencing due to the ability to detect low-frequency variants. To clarify a clinical benefit to monitoring minority-level drug resistance populations as a guide to select active drugs for salvage therapy, we retrospectively analyzed the dynamics of low-frequency drug-resistant population in antiretroviral (ARV)-exposed drug resistant individuals. Materials and Methods Six HIV-infected individuals treated with ARV for more than five years were analyzed. These individuals had difficulty in controlling viremia, and treatment regimens were switched multiple times guided by standard drug resistance testing using bulk sequencing. To detect minority variant populations with drug resistance, we used a highly sensitive allele-specific PCR (AS-PCR) with detection thresholds of 0.3–2%. According to ARV used in these individuals, we focused on the following seven reverse transcriptase inhibitor-resistant mutations: M41L, K65R, K70R, K103N, Y181C, M184V, and T215F/Y. Results of AS-PCR were compared with bulk sequencing data for concordance and presence of additional mutations. To clarify the genetic relationship between low-frequency and high-frequency populations, AS-PCR amplicon sequences were compared with bulk sequences in phylogenetic analysis. Results The use of AS-PCR enabled detection of the drug-resistant mutations, M41L, K103N, Y181C, M184V and T215Y, present as low-frequency populations in five of the six individuals. These drug resistant variants persisted for several years without ARV pressure. Phylogenetic analysis indicated that pre-existing K103N and T215I variants had close genetic relationships with high-frequency K103N and T215I observed during treatment. Discussion and Conclusion Our results demonstrate the long-term persistence of drug-resistant viruses in the absence of drug pressure. The rapid virologic failures with pre-existing mutant viruses detectable by AS-PCR highlight the clinical importance of low-frequency drug-resistant viruses. Thus, our results highlight the usefulness of AS-PCR and support its expanded evaluation in ART clinical management. PMID:26360259

  15. State observers and Kalman filtering for high performance vibration isolation systems.

    PubMed

    Beker, M G; Bertolini, A; van den Brand, J F J; Bulten, H J; Hennes, E; Rabeling, D S

    2014-03-01

    There is a strong scientific case for the study of gravitational waves at or below the lower end of current detection bands. To take advantage of this scientific benefit, future generations of ground based gravitational wave detectors will need to expand the limit of their detection bands towards lower frequencies. Seismic motion presents a major challenge at these frequencies and vibration isolation systems will play a crucial role in achieving the desired low-frequency sensitivity. A compact vibration isolation system designed to isolate in-vacuum optical benches for Advanced Virgo will be introduced and measurements on this system are used to present its performance. All high performance isolation systems employ an active feedback control system to reduce the residual motion of their suspended payloads. The development of novel control schemes is needed to improve the performance beyond what is currently feasible. Here, we present a multi-channel feedback approach that is novel to the field. It utilizes a linear quadratic regulator in combination with a Kalman state observer and is shown to provide effective suppression of residual motion of the suspended payload. The application of state observer based feedback control for vibration isolation will be demonstrated with measurement results from the Advanced Virgo optical bench suspension system.

  16. Satellite-Based EMI Detection, Identification, and Mitigation

    NASA Astrophysics Data System (ADS)

    Stottler, R.; Bowman, C.

    2016-09-01

    Commanding, controlling, and maintaining the health of satellites requires a clear operating spectrum for communications. Electro Magnetic Interference (EMI) from other satellites can interfere with these communications. Determining which satellite is at fault improves space situational awareness and can be used to avoid the problem in the future. The Rfi detection And Prediction Tool, Optimizing Resources (RAPTOR) monitors the satellite communication antenna signals to detect EMI (also called RFI for Radio Frequency Interference) using a neural network trained on past cases of both normal communications and EMI events. RAPTOR maintains a database of satellites that have violated the reserved spectrum in the past. When satellite-based EMI is detected, RAPTOR first checks this list to determine if any are angularly close to the satellite being communicated with. Additionally, RAPTOR checks the Space Catalog to see if any of its active satellites are angularly close. RAPTOR also consults on-line databases to determine if the described operating frequencies of the satellites match the detected EMI and recommends candidates to be added to the known offenders database, accordingly. Based on detected EMI and predicted orbits and frequencies, RAPTOR automatically reschedules satellite communications to avoid current and future satellite-based EMI. It also includes an intuitive display for a global network of satellite communications antennas and their statuses including the status of their EM spectrum. RAPTOR has been prototyped and tested with real data (amplitudes versus frequency over time) for both satellite communication signals and is currently undergoing full-scale development. This paper describes the RAPTOR technologies and results of testing.

  17. Structural damage identification using damping: a compendium of uses and features

    NASA Astrophysics Data System (ADS)

    Cao, M. S.; Sha, G. G.; Gao, Y. F.; Ostachowicz, W.

    2017-04-01

    The vibration responses of structures under controlled or ambient excitation can be used to detect structural damage by correlating changes in structural dynamic properties extracted from responses with damage. Typical dynamic properties refer to modal parameters: natural frequencies, mode shapes, and damping. Among these parameters, natural frequencies and mode shapes have been investigated extensively for their use in damage characterization by associating damage with reduction in local stiffness of structures. In contrast, the use of damping as a dynamic property to represent structural damage has not been comprehensively elucidated, primarily due to the complexities of damping measurement and analysis. With advances in measurement technologies and analysis tools, the use of damping to identify damage is becoming a focus of increasing attention in the damage detection community. Recently, a number of studies have demonstrated that damping has greater sensitivity for characterizing damage than natural frequencies and mode shapes in various applications, but damping-based damage identification is still a research direction ‘in progress’ and is not yet well resolved. This situation calls for an overall survey of the state-of-the-art and the state-of-the-practice of using damping to detect structural damage. To this end, this study aims to provide a comprehensive survey of uses and features of applying damping in structural damage detection. First, we present various methods for damping estimation in different domains including the time domain, the frequency domain, and the time-frequency domain. Second, we investigate the features and applications of damping-based damage detection methods on the basis of two predominant infrastructure elements, reinforced concrete structures and fiber-reinforced composites. Third, we clarify the influential factors that can impair the capability of damping to characterize damage. Finally, we recommend future research directions for advancing damping-based damage detection. This work holds the promise of (a) helping researchers identify crucial components in damping-based damage detection theories, methods, and technologies, and (b) leading practitioners to better implement damping-based structural damage identification.

  18. Dual-thread parallel control strategy for ophthalmic adaptive optics.

    PubMed

    Yu, Yongxin; Zhang, Yuhua

    To improve ophthalmic adaptive optics speed and compensate for ocular wavefront aberration of high temporal frequency, the adaptive optics wavefront correction has been implemented with a control scheme including 2 parallel threads; one is dedicated to wavefront detection and the other conducts wavefront reconstruction and compensation. With a custom Shack-Hartmann wavefront sensor that measures the ocular wave aberration with 193 subapertures across the pupil, adaptive optics has achieved a closed loop updating frequency up to 110 Hz, and demonstrated robust compensation for ocular wave aberration up to 50 Hz in an adaptive optics scanning laser ophthalmoscope.

  19. Dual-thread parallel control strategy for ophthalmic adaptive optics

    PubMed Central

    Yu, Yongxin; Zhang, Yuhua

    2015-01-01

    To improve ophthalmic adaptive optics speed and compensate for ocular wavefront aberration of high temporal frequency, the adaptive optics wavefront correction has been implemented with a control scheme including 2 parallel threads; one is dedicated to wavefront detection and the other conducts wavefront reconstruction and compensation. With a custom Shack-Hartmann wavefront sensor that measures the ocular wave aberration with 193 subapertures across the pupil, adaptive optics has achieved a closed loop updating frequency up to 110 Hz, and demonstrated robust compensation for ocular wave aberration up to 50 Hz in an adaptive optics scanning laser ophthalmoscope. PMID:25866498

  20. Unique capabilities of AC frequency scanning and its implementation on a Mars Organic Molecule Analyzer linear ion trap.

    PubMed

    Snyder, Dalton T; Kaplan, Desmond A; Danell, Ryan M; van Amerom, Friso H W; Pinnick, Veronica T; Brinckerhoff, William B; Mahaffy, Paul R; Cooks, R Graham

    2017-06-21

    A limitation of conventional quadrupole ion trap scan modes which use rf amplitude control for mass scanning is that, in order to detect a subset of an ion population, the rest of the ion population must also be interrogated. That is, ions cannot be detected out of order; they must be detected in order of either increasing or decreasing mass-to-charge (m/z). However, an ion trap operated in the ac frequency scan mode, where the rf amplitude is kept constant and instead the ac frequency is used for mass-selective operations, has no such limitation because any variation in the ac frequency affects only the subset of ions whose secular frequencies match the perturbation frequency. Hence, an ion trap operated in the ac frequency scan mode can perform any arbitrary mass scan, as well as a sequence of scans, using a single ion injection; we demonstrate both capabilities here. Combining these two capabilities, we demonstrate the acquisition of a full mass spectrum, a product ion spectrum, and a second generation product ion spectrum using a single ion injection event. We further demonstrate a "segmented scan" in which different mass ranges are interrogated at different rf amplitudes in order to improve resolution over a portion of the mass range, and a "periodic scan" in which ions are continuously introduced into the ion trap to achieve a nearly 100% duty cycle. These unique scan modes, along with other characteristics of ac frequency scanning, are particularly appropriate for miniature ion trap mass spectrometers. Hence, implementation of ac frequency scanning on a prototype of the Mars Organic Molecule Analyzer mass spectrometer is also described.

  1. Design of remote control alarm system by microwave detection

    NASA Astrophysics Data System (ADS)

    Wang, Junli

    2018-04-01

    A microwave detection remote control alarm system is designed, which is composed of a Microwave detectors, a radio receiving/transmitting module and a digital encoding/decoding IC. When some objects move into the surveillance area, microwave detectors will generate a control signal to start transmitting system. A radio control signal will be spread by the transmitting module, once the signal can be received, and it will be disposed by some circuits, arousing some voices that awake the watching people. The whole device is a modular configuration, it not only has some advantage of frequency stable, but also reliable and adjustment-free, and it is suitable for many kinds of demands within the distance of 100m.

  2. Apparatus and method for microwave processing of materials

    DOEpatents

    Johnson, Arvid C.; Lauf, Robert J.; Bible, Don W.; Markunas, Robert J.

    1996-01-01

    A variable frequency microwave heating apparatus (10) designed to allow modulation of the frequency of the microwaves introduced into a furnace cavity (34) for testing or other selected applications. The variable frequency heating apparatus (10) is used in the method of the present invention to monitor the resonant processing frequency within the furnace cavity (34) depending upon the material, including the state thereof, from which the workpiece (36) is fabricated. The variable frequency microwave heating apparatus (10) includes a microwave signal generator (12) and a high-power microwave amplifier (20) or a microwave voltage-controlled oscillator (14). A power supply (22) is provided for operation of the high-power microwave oscillator (14) or microwave amplifier (20). A directional coupler (24) is provided for detecting the direction and amplitude of signals incident upon and reflected from the microwave cavity (34). A first power meter (30) is provided for measuring the power delivered to the microwave furnace (32). A second power meter (26) detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load (28).

  3. [Relationship between the Fnu4HI site polymorphism of monoamine oxidase A gene and Parkinson's disease].

    PubMed

    Jiang, Xiao-hua; Yang, Hui; Yang, Jing-fang; Dong, Xiu-min; Xu, Qun-yuan; Chen, Biao

    2003-06-01

    To study the association between the polymorphism of human monoamine oxidase type A (MAO-A) gene and Parkinson's disease(PD). Fnu4HI restriction fragment length polymorphism(RFLP) and PCR-RFLP were used to detect the mutation of MAO-A gene. The frequencies of alleles and genotypes at the MAO-A Fnu4HI locus on the X chromosome in different PD group were compared with those of the control group. It was found that the frequencies of G allele in the patients with PD and controls were 0.613 and 0.527 respectively, P=0.039 "the frequencies of TT genotype were 0.303 and 0.415(P=0.014), and the frequencies of GG genotype were 0.564 and 0.451 respectively(P=0.021). When the patients were divided into two groups by age-onset, significant difference in the allelic and genotypic frequencies was observed only between early-onset PD group and control group. And when the PD patients were grouped by sex, significant difference was observed only between male PD group and male control group (the frequencies of G allele being 0.669 and 0.500 respectively, P=0.005). This study revealed significant differences between PD group and control group in allelic and genotypic frequencies. The findings supported the hypothesis about an association between MAO-A gene and PD, suggesting that age at onset of PD and gender predisposition might be related to the putative association, and Fnu4HI SNP be a risk factor for PD.

  4. Hand-arm vibration syndrome: clinical characteristics, conventional electrophysiology and quantitative sensory testing.

    PubMed

    Rolke, Roman; Rolke, Silke; Vogt, Thomas; Birklein, Frank; Geber, Christian; Treede, Rolf-Detlef; Letzel, Stephan; Voelter-Mahlknecht, Susanne

    2013-08-01

    Workers exposed to vibrating tools may develop hand-arm vibration syndrome (HAVS). We assessed the somatosensory phenotype using quantitative sensory testing (QST) in comparison to electrophysiology to characterize (1) the most sensitive QST parameter for detecting sensory loss, (2) the correlation of QST and electrophysiology, and (3) the frequency of a carpal tunnel syndrome (CTS) in HAVS. QST, cold provocation tests, fine motor skills, and median nerve neurography were used. QST included thermal and mechanical detection and pain thresholds. Thirty-two patients were examined (54 ± 11 years, 91% men) at the more affected hand compared to 16 matched controls. Vibration detection threshold was the most sensitive parameter to detect sensory loss that was more pronounced in the sensitivity range of Pacinian (150 Hz, x12) than Meissner's corpuscles (20 Hz, x3). QST (84% abnormal) was more sensitive to detect neural dysfunction than conventional electrophysiology (37% abnormal). Motor (34%) and sensory neurography (25%) were abnormal in HAVS. CTS frequency was not increased (9.4%). Findings are consistent with a mechanically-induced, distally pronounced motor and sensory neuropathy independent of CTS. HAVS involves a neuropathy predominantly affecting large fibers with a sensory damage related to resonance frequencies of vibrating tools. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Experience with dynamic reinforcement rates decreases resistance to extinction.

    PubMed

    Craig, Andrew R; Shahan, Timothy A

    2016-03-01

    The ability of organisms to detect reinforcer-rate changes in choice preparations is positively related to two factors: the magnitude of the change in rate and the frequency with which rates change. Gallistel (2012) suggested similar rate-detection processes are responsible for decreases in responding during operant extinction. Although effects of magnitude of change in reinforcer rate on resistance to extinction are well known (e.g., the partial-reinforcement-extinction effect), effects of frequency of changes in rate prior to extinction are unknown. Thus, the present experiments examined whether frequency of changes in baseline reinforcer rates impacts resistance to extinction. Pigeons pecked keys for variable-interval food under conditions where reinforcer rates were stable and where they changed within and between sessions. Overall reinforcer rates between conditions were controlled. In Experiment 1, resistance to extinction was lower following exposure to dynamic reinforcement schedules than to static schedules. Experiment 2 showed that resistance to presession feeding, a disruptor that should not involve change-detection processes, was unaffected by baseline-schedule dynamics. These findings are consistent with the suggestion that change detection contributes to extinction. We discuss implications of change-detection processes for extinction of simple and discriminated operant behavior and relate these processes to the behavioral-momentum based approach to understanding extinction. © 2016 Society for the Experimental Analysis of Behavior.

  6. High-frequency acoustic spectrum analyzer based on polymer integrated optics

    NASA Astrophysics Data System (ADS)

    Yacoubian, Araz

    This dissertation presents an acoustic spectrum analyzer based on nonlinear polymer-integrated optics. The device is used in a scanning heterodyne geometry by zero biasing a Michelson interferometer. It is capable of detecting vibrations from DC to the GHz range. Initial low frequency experiments show that the device is an effective tool for analyzing an acoustic spectrum even in noisy environments. Three generations of integrated sensors are presented, starting with a very lossy (86 dB total insertion loss) initial device that detects vibrations as low as λ/10, and second and third generation improvements with a final device of 44 dB total insertion loss. The sensor was further tested for detecting a pulsed laser-excited vibration and resonances due to the structure of the sample. The data are compared to the acoustic spectrum measured using a low loss passive fiber interferometer detection scheme which utilizes a high speed detector. The peaks present in the passive detection scheme are clearly visible with our sensor data, which have a lower noise floor. Hybrid integration of GHz electronics is also investigated in this dissertation. A voltage controlled oscillator (VCO) is integrated on a polymer device using a new approach. The VCO is shown to operate as specified by the manufacturer, and the RF signal is efficiently launched onto the micro-strip line used for EO modulation. In the future this technology can be used in conjunction with the presented sensor to produce a fully integrated device containing high frequency drive electronics controlled by low DC voltage. Issues related to device fabrication, loss analysis, RF power delivery to drive circuitry, efficient poling of large area samples, and optimizing poling conditions are also discussed throughout the text.

  7. Undisturbed dust as a metric of long-term indoor insecticide exposure: Residential DDT contamination from indoor residual spraying and its association with serum levels in the VHEMBE cohort.

    PubMed

    Gaspar, Fraser W; Chevrier, Jonathan; Bornman, Riana; Crause, Madelein; Obida, Muvhulawa; Barr, Dana Boyd; Bradman, Asa; Bouwman, Henk; Eskenazi, Brenda

    2015-12-01

    Although approximately 123 million people may be exposed to high levels of insecticides through the use of indoor residual spraying (IRS) for malaria control, few studies exist on indoor insecticide contamination due to IRS and its relationship with human exposure. In the present study, we developed a sampling method to collect undisturbed dust from 50 homes in Limpopo, South Africa, a region where dichlorodiphenyltrichloroethane (DDT) has been used in IRS programs to prevent malaria for ~70years. We quantified DDT and its degradation products, dichlorodiphenyldichloroethylene (DDE), and dichlorodiphenyldichloroethane (DDD) in dust samples to determine dust loading levels and compared these levels to paired serum concentrations of p,p'-DDT and p,p'-DDE in women residents. p,p'-DDT and p,p'-DDE had the highest detection frequencies in both dust (58% and 34% detection, respectively) and serum samples (98% and 100% detection, respectively). Significantly higher detection frequencies for o,p'-DDT, p,p'-DDE, and p,p'-DDD were observed in dust samples collected in buildings that had been previously sprayed for malaria control. We also observed a significant, positive association between dust loading and serum concentrations of p,p'-DDT and p,p'-DDE (Spearman's rho=0.68 and 0.54, respectively). Despite the low detection frequency in dust, our results indicate that undisturbed dust may be a good metric to quantify long-term home exposure to DDT-related compounds and that contamination of the home environment may be an important determinant/source of DDT and DDE exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Kullback-Leibler divergence for detection of rare haplotype common disease association.

    PubMed

    Lin, Shili

    2015-11-01

    Rare haplotypes may tag rare causal variants of common diseases; hence, detection of such rare haplotypes may also contribute to our understanding of complex disease etiology. Because rare haplotypes frequently result from common single-nucleotide polymorphisms (SNPs), focusing on rare haplotypes is much more economical compared with using rare single-nucleotide variants (SNVs) from sequencing, as SNPs are available and 'free' from already amassed genome-wide studies. Further, associated haplotypes may shed light on the underlying disease causal mechanism, a feat unmatched by SNV-based collapsing methods. In recent years, data mining approaches have been adapted to detect rare haplotype association. However, as they rely on an assumed underlying disease model and require the specification of a null haplotype, results can be erroneous if such assumptions are violated. In this paper, we present a haplotype association method based on Kullback-Leibler divergence (hapKL) for case-control samples. The idea is to compare haplotype frequencies for the cases versus the controls by computing symmetrical divergence measures. An important property of such measures is that both the frequencies and logarithms of the frequencies contribute in parallel, thus balancing the contributions from rare and common, and accommodating both deleterious and protective, haplotypes. A simulation study under various scenarios shows that hapKL has well-controlled type I error rates and good power compared with existing data mining methods. Application of hapKL to age-related macular degeneration (AMD) shows a strong association of the complement factor H (CFH) gene with AMD, identifying several individual rare haplotypes with strong signals.

  9. Quantitative phase and texture angularity analysis of brain white matter lesions in multiple sclerosis

    NASA Astrophysics Data System (ADS)

    Baxandall, Shalese; Sharma, Shrushrita; Zhai, Peng; Pridham, Glen; Zhang, Yunyan

    2018-03-01

    Structural changes to nerve fiber tracts are extremely common in neurological diseases such as multiple sclerosis (MS). Accurate quantification is vital. However, while nerve fiber damage is often seen as multi-focal lesions in magnetic resonance imaging (MRI), measurement through visual perception is limited. Our goal was to characterize the texture pattern of the lesions in MRI and determine how texture orientation metrics relate to lesion structure using two new methods: phase congruency and multi-resolution spatial-frequency analysis. The former aims to optimize the detection of the `edges and corners' of a structure, and the latter evaluates both the radial and angular distributions of image texture associated with the various forming scales of a structure. The radial texture spectra were previously confirmed to measure the severity of nerve fiber damage, and were thus included for validation. All measures were also done in the control brain white matter for comparison. Using clinical images of MS patients, we found that both phase congruency and weighted mean phase detected invisible lesion patterns and were significantly greater in lesions, suggesting higher structure complexity, than the control tissue. Similarly, multi-angular spatial-frequency analysis detected much higher texture across the whole frequency spectrum in lesions than the control areas. Such angular complexity was consistent with findings from radial texture. Analysis of the phase and texture alignment may prove to be a useful new approach for assessing invisible changes in lesions using clinical MRI and thereby lead to improved management of patients with MS and similar disorders.

  10. Development of fast wireless detection system for fixed offshore platform

    NASA Astrophysics Data System (ADS)

    Li, Zhigang; Yu, Yan; Jiao, Dong; Wang, Jie; Li, Zhirui; Ou, Jinping

    2011-04-01

    Offshore platforms' security is concerned since in 1950s and 1960s, and in the early 1980s some important specifications and standards are built, and all these provide technical basis of fixed platform design, construction, installation and evaluation. With the condition that more and more platforms are in serving over age, the research about the evaluation and detection technology of offshore platform has been a hotspot, especially underwater detection, and assessment method based on the finite element calculation. For fixed platform structure detection, conventional NDT methods, such as eddy current, magnetic powder, permeate, X-ray and ultrasonic, etc, are generally used. These techniques are more mature, intuitive, but underwater detection needs underwater robot, the necessary supporting tools of auxiliary equipment, and trained professional team, thus resources and cost used are considerable, installation time of test equipment is long. This project presents a new kind of fast wireless detection and damage diagnosis system for fixed offshore platform using wireless sensor networks, that is, wireless sensor nodes can be put quickly on the offshore platform, detect offshore platform structure global status by wireless communication, and then make diagnosis. This system is operated simply, suitable for offshore platform integrity states rapid assessment. The designed system consists in intelligence acquisition equipment and 8 wireless collection nodes, the whole system has 64 collection channels, namely every wireless collection node has eight 16-bit accuracy of A/D channels. Wireless collection node, integrated with vibration sensing unit, embedded low-power micro-processing unit, wireless transceiver unit, large-capacity power unit, and GPS time synchronization unit, can finish the functions such as vibration data collection, initial analysis, data storage, data wireless transmission. Intelligence acquisition equipment, integrated with high-performance computation unit, wireless transceiver unit, mobile power unit and embedded data analysis software, can totally control multi-wireless collection nodes, receive and analyze data, parameter identification. Data is transmitted at the 2.4GHz wireless communication channel, every sensing data channel in charge of data transmission is in a stable frequency band, control channel responsible for the control of power parameters is in a public frequency band. The test is initially conducted for the designed system, experimental results show that the system has good application prospects and practical value with fast arrangement, high sampling rate, high resolution, capacity of low frequency detection.

  11. Ultrasensitive, self-calibrated cavity ring-down spectrometer for quantitative trace gas analysis.

    PubMed

    Chen, Bing; Sun, Yu R; Zhou, Ze-Yi; Chen, Jian; Liu, An-Wen; Hu, Shui-Ming

    2014-11-10

    A cavity ring-down spectrometer is built for trace gas detection using telecom distributed feedback (DFB) diode lasers. The longitudinal modes of the ring-down cavity are used as frequency markers without active-locking either the laser or the high-finesse cavity. A control scheme is applied to scan the DFB laser frequency, matching the cavity modes one by one in sequence and resulting in a correct index at each recorded spectral data point, which allows us to calibrate the spectrum with a relative frequency precision of 0.06 MHz. Besides the frequency precision of the spectrometer, a sensitivity (noise-equivalent absorption) of 4×10-11  cm-1  Hz-1/2 has also been demonstrated. A minimum detectable absorption coefficient of 5×10-12  cm-1 has been obtained by averaging about 100 spectra recorded in 2  h. The quantitative accuracy is tested by measuring the CO2 concentrations in N2 samples prepared by the gravimetric method, and the relative deviation is less than 0.3%. The trace detection capability is demonstrated by detecting CO2 of ppbv-level concentrations in a high-purity nitrogen gas sample. Simple structure, high sensitivity, and good accuracy make the instrument very suitable for quantitative trace gas analysis.

  12. Determination of Vascular Dementia Brain in Distinct Frequency Bands with Whole Brain Functional Connectivity Patterns

    PubMed Central

    Zhang, Delong; Liu, Bo; Chen, Jun; Peng, Xiaoling; Liu, Xian; Fan, Yuanyuan; Liu, Ming; Huang, Ruiwang

    2013-01-01

    Recent studies have shown that multivariate pattern analysis (MVPA) can be useful for distinguishing brain disorders into categories. Such analyses can substantially enrich and facilitate clinical diagnoses. Using MPVA methods, whole brain functional networks, especially those derived using different frequency windows, can be applied to detect brain states. We constructed whole brain functional networks for groups of vascular dementia (VaD) patients and controls using resting state BOLD-fMRI (rsfMRI) data from three frequency bands - slow-5 (0.01∼0.027 Hz), slow-4 (0.027∼0.073 Hz), and whole-band (0.01∼0.073 Hz). Then we used the support vector machine (SVM), a type of MVPA classifier, to determine the patterns of functional connectivity. Our results showed that the brain functional networks derived from rsfMRI data (19 VaD patients and 20 controls) in these three frequency bands appear to reflect neurobiological changes in VaD patients. Such differences could be used to differentiate the brain states of VaD patients from those of healthy individuals. We also found that the functional connectivity patterns of the human brain in the three frequency bands differed, as did their ability to differentiate brain states. Specifically, the ability of the functional connectivity pattern to differentiate VaD brains from healthy ones was more efficient in the slow-5 (0.01∼0.027 Hz) band than in the other two frequency bands. Our findings suggest that the MVPA approach could be used to detect abnormalities in the functional connectivity of VaD patients in distinct frequency bands. Identifying such abnormalities may contribute to our understanding of the pathogenesis of VaD. PMID:23359801

  13. Detection of an enzootic plague focus by serological methods

    PubMed Central

    Cavanaugh, D. C.; Thorpe, B. D.; Bushman, J. B.; Nicholes, P. S.; Rust, J. H.

    1965-01-01

    Complement-fixation and haemagglutination tests, utilizing a highly purified, specific Fraction 1 antigen of Pasteurella pestis, have been employed to detect specific plague antibody in the sera of rodents resident in a sylvatic plague focus. The data show that while the isolation of P. pestis is seasonal and rather rare, antibodies can be detected for long periods of time and with great frequency in rodents surviving infection. The authors recommend that serological methods be incorporated into epidemiological surveys and control programmes involving rodent plague. PMID:14310906

  14. DETECTION OF AN ENZOOTIC PLAGUE FOCUS BY SEROLOGICAL METHODS.

    PubMed

    CAVANAUGH, D C; THORPE, B D; BUSHMAN, J B; NICHOLES, P S; RUST, J H

    1965-01-01

    Complement-fixation and haemagglutination tests, utilizing a highly purified, specific Fraction 1 antigen of Pasteurella pestis, have been employed to detect specific plague antibody in the sera of rodents resident in a sylvatic plague focus. The data show that while the isolation of P. pestis is seasonal and rather rare, antibodies can be detected for long periods of time and with great frequency in rodents surviving infection. The authors recommend that serological methods be incorporated into epidemiological surveys and control programmes involving rodent plague.

  15. Phase-locked, erbium-fiber-laser-based frequency comb in the near infrared.

    PubMed

    Washburn, Brian R; Diddams, Scott A; Newbury, Nathan R; Nicholson, Jeffrey W; Yan, Man F; Jørgensen, Carsten G

    2004-02-01

    A phase-locked frequency comb in the near infrared is demonstrated with a mode-locked, erbium-doped, fiber laser whose output is amplified and spectrally broadened in dispersion-flattened, highly nonlinear optical fiber to span from 1100 to >2200 nm. The supercontinuum output comprises a frequency comb with a spacing set by the laser repetition rate and an offset by the carrier-envelope offset frequency, which is detected with the standard f-to-2f heterodyne technique. The comb spacing and offset frequency are phase locked to a stable rf signal with a fiber stretcher in the laser cavity and by control of the pump laser power, respectively. This infrared comb permits frequency metrology experiments in the near infrared in a compact, fiber-laser-based system.

  16. Degree and frequency of inhibition in a routine real-time PCR detecting Pneumocystis jirovecii for the diagnosis of Pneumocystis pneumonia in Turkey.

    PubMed

    Döskaya, Mert; Caner, Ayse; Degirmenci, Aysu; Wengenack, Nancy L; Yolasigmaz, Aysegül; Turgay, Nevin; Ozensoy Töz, Seray; Gürüz, Yüksel

    2011-07-01

    Routine laboratory diagnosis of Pneumocystis jirovecii is currently achieved by PCR in almost all laboratories with sufficient equipment due to its high sensitivity and specificity compared to staining methods. A current issue that limits the reliability and sensitivity of PCR is the degree of inhibition caused by inhibitory substances in respiratory samples. The present study aimed to analyse the degree and frequency of inhibition in real-time PCR detecting P. jirovecii in respiratory specimens submitted to a Pneumocystis pneumonia (PcP) diagnosis laboratory in Ege University Medical School, Turkey. Between July 2009 and December 2010, 76 respiratory specimens [63 bronchoalveolar lavage (BAL) fluid, 10 sputum samples, two tracheal aspiration fluid and one thoracentesis fluid] obtained from 69 PcP-suspected patients were investigated for the presence of P. jirovecii using real-time PCR targeting the cdc2 gene. Of these samples, 42 of the specimens were stained and examined by microscopy according to the request of the clinicians. PCR was positive in 15 specimens in the initial run. Of the remaining 61 samples, 41 of them were negative with positive internal inhibition controls (i.e. true-negative group). The frequency of inhibition in the initial run was 26.31 % (20/76) as determined by spiked negative controls. All of the inhibited samples were resolved after 1 : 2, 1 : 5, 1 : 10 and 1 : 20 dilutions. P. jirovecii was detected by PCR in two inhibited specimens after retesting with diluted samples which were also positive by microscopy. The incidence of P. jirovecii in respiratory specimens was 22.36 % (17/76) as determined by real-time PCR and 7.14 % (3/42) by microscopy. Overall, the incidence of P. jirovecii in respiratory samples was 23.68 % (18/76) as detected by both methods. In conclusion, inclusion of spiked positive controls in each sample and retesting with diluted samples to resolve inhibition increased the reliability of the real-time PCR assay in terms of determining false-negative results and influencing the treatment of the patient. Furthermore, results of the present study determined for the first time the frequency and degree of inhibition in a real-time PCR detecting P. jirovecii in respiratory specimens during routine diagnosis of PcP.

  17. Frequency of Dendritic Cells and Their Expression of Costimulatory Molecules in Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Saad, Khaled; Zahran, Asmaa M.; Elsayh, Khalid I.; Abdel-Rahman, Ahmed A.; Al-Atram, Abdulrahman A.; Hussein, Almontaser; El-Gendy, Yasmin G.

    2017-01-01

    The aim of our study was to evaluate the frequencies of myeloid dendritic cells (mDCs) and plasmacytoid dendritic cells (pDCs) in children with ASD. Subjects were 32 children with ASD and 30 healthy children as controls. The numbers of mDCs and pDCs and the expression of CD86 and CD80 on the entire DCs were detected by flow cytometry. ASD children…

  18. Closed-loop pulsed helium ionization detector

    DOEpatents

    Ramsey, Roswitha S.; Todd, Richard A.

    1987-01-01

    A helium ionization detector for gas chromatography is operated in a constant current, pulse-modulated mode by configuring the detector, electrometer and a high voltage pulser in a closed-loop control system. The detector current is maintained at a fixed level by varying the frequency of fixed-width, high-voltage bias pulses applied to the detector. An output signal proportional to the pulse frequency is produced which is indicative of the charge collected for a detected species.

  19. Detection of driver metabolites in the human liver metabolic network using structural controllability analysis

    PubMed Central

    2014-01-01

    Background Abnormal states in human liver metabolism are major causes of human liver diseases ranging from hepatitis to hepatic tumor. The accumulation in relevant data makes it feasible to derive a large-scale human liver metabolic network (HLMN) and to discover important biological principles or drug-targets based on network analysis. Some studies have shown that interesting biological phenomenon and drug-targets could be discovered by applying structural controllability analysis (which is a newly prevailed concept in networks) to biological networks. The exploration on the connections between structural controllability theory and the HLMN could be used to uncover valuable information on the human liver metabolism from a fresh perspective. Results We applied structural controllability analysis to the HLMN and detected driver metabolites. The driver metabolites tend to have strong ability to influence the states of other metabolites and weak susceptibility to be influenced by the states of others. In addition, the metabolites were classified into three classes: critical, high-frequency and low-frequency driver metabolites. Among the identified 36 critical driver metabolites, 27 metabolites were found to be essential; the high-frequency driver metabolites tend to participate in different metabolic pathways, which are important in regulating the whole metabolic systems. Moreover, we explored some other possible connections between the structural controllability theory and the HLMN, and find that transport reactions and the environment play important roles in the human liver metabolism. Conclusion There are interesting connections between the structural controllability theory and the human liver metabolism: driver metabolites have essential biological functions; the crucial role of extracellular metabolites and transport reactions in controlling the HLMN highlights the importance of the environment in the health of human liver metabolism. PMID:24885538

  20. An Active Z Gravity Compensation System

    DTIC Science & Technology

    1992-07-01

    is necessary to convert the modified digital controller back into continuous time, assuming a zero -order hold for output, and using the Padd ...most likely higher frequency pole- zero pairs introduced by the motor and torque servo, these are generally non-oscillatory, and small in amplitude...on the output of the PI control. The detection scheme is the following: if the output of the fuzzy controller has remained zero (static system) for

  1. Millimeter wave sensor for monitoring effluents

    DOEpatents

    Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Dieckman, Stephen L.

    1995-01-01

    A millimeter-wave sensor for detecting and measuring effluents from processing plants either remotely or on-site includes a high frequency signal source for transmitting frequency-modulated continuous waves in the millimeter or submillimeter range with a wide sweep capability and a computer-controlled detector for detecting a plurality of species of effluents on a real time basis. A high resolution spectrum of an effluent, or effluents, is generated by a deconvolution of the measured spectra resulting in a narrowing of the line widths by 2 or 3 orders of magnitude as compared with the pressure broadened spectra detected at atmospheric pressure for improved spectral specificity and measurement sensitivity. The sensor is particularly adapted for remote monitoring such as where access is limited or sensor cost restricts multiple sensors as well as for large area monitoring under nearly all weather conditions.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Moses; Kim, Keonhui; Muljadi, Eduard

    This paper proposes a torque limit-based inertial control scheme of a doubly-fed induction generator (DFIG) that supports the frequency control of a power system. If a frequency deviation occurs, the proposed scheme aims to release a large amount of kinetic energy (KE) stored in the rotating masses of a DFIG to raise the frequency nadir (FN). Upon detecting the event, the scheme instantly increases its output to the torque limit and then reduces the output with the rotor speed so that it converges to the stable operating range. To restore the rotor speed while causing a small second frequency dipmore » (SFD), after the rotor speed converges the power reference is reduced by a small amount and maintained until it meets the reference for maximum power point tracking control. The test results demonstrate that the scheme can improve the FN and maximum rate of change of frequency while causing a small SFD in any wind conditions and in a power system that has a high penetration of wind power, and thus the scheme helps maintain the required level of system reliability. The scheme releases the KE from 2.9 times to 3.7 times the Hydro-Quebec requirement depending on the power reference.« less

  3. ACE: an efficient and sensitive tool to detect insecticide resistance-associated mutations in insect acetylcholinesterase from RNA-Seq data.

    PubMed

    Guo, Dianhao; Luo, Jiapeng; Zhou, Yuenan; Xiao, Huamei; He, Kang; Yin, Chuanlin; Xu, Jianhua; Li, Fei

    2017-07-10

    Insecticide resistance is a substantial problem in controlling agricultural and medical pests. Detecting target site mutations is crucial to manage insecticide resistance. Though PCR-based methods have been widely used in this field, they are time-consuming and inefficient, and typically have a high false positive rate. Acetylcholinesterases (Ace) is the neural target of the widely used organophosphate (OP) and carbamate insecticides. However, there is not any software available to detect insecticide resistance associated mutations in RNA-Seq data at present. A computational pipeline ACE was developed to detect resistance mutations of ace in insect RNA-Seq data. Known ace resistance mutations were collected and used as a reference. We constructed a Web server for ACE, and the standalone software in both Linux and Windows versions is available for download. ACE was used to analyse 971 RNA-Seq data from 136 studies in 7 insect pests. The mutation frequency of each RNA-Seq dataset was calculated. The results indicated that the resistance frequency was 30%-44% in an eastern Ugandan Anopheles population, thus suggesting this resistance-conferring mutation has reached high frequency in these mosquitoes in Uganda. Analyses of RNA-Seq data from the diamondback moth Plutella xylostella indicated that the G227A mutation was positively related with resistance levels to organophosphate or carbamate insecticides. The wasp Nasonia vitripennis had a low frequency of resistant reads (<5%), but the agricultural pests Chilo suppressalis and Bemisia tabaci had a high resistance frequency. All ace reads in the 30 B. tabaci RNA-Seq data were resistant reads, suggesting that insecticide resistance has spread to very high frequency in B. tabaci. To the best of our knowledge, the ACE pipeline is the first tool to detect resistance mutations from RNA-Seq data, and it facilitates the full utilization of large-scale genetic data obtained by using next-generation sequencing.

  4. [Study on the relationship of MTHFR polymorphisms with unexplained recurrent spontaneous abortion].

    PubMed

    Li, Xiao-mei; Zhang, You-zhong; Xu, Yan-xue; Jiang, Sen

    2004-02-01

    To assess the relationship of methylenetetrahydrofolate reductase (MTHFR) C677T genotypes to unexplained recurrent spontaneous abortion (URSA). This study included two groups:57 currently non-pregnant women with a history of URSA (URSA group), and 50 currently non-pregnant women with a history of having given birth to at least one live baby and without any history of spontaneous abortion, still-born fetus, placental thrombosis and intrauterine growth retardation(IUGR)(control group). The fasting serum-Hcy was measured with high pressure liquid chromatography. Folic acid and vitamin B(12) were detected by radioimmune assay; antiphospholipid antibody (ACA) was detected by ELISA. MTHFR C677T gene polymorphisms were detected by the technique of polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). C/C genotype in URSA group was significantly lower than that in control group, the total mutant T allele frequency was significantly higher than that in control group. There was no significant difference in respect of "age, rural area/city, period, primary/secondary abortion" between the genotype distributions of MTHFR C677T. The T/T genotype and C/T+T/T genotypes frequencies for "abortion times>or=3" were higher than those for "abortion time <3". MTHFR C677T gene polymorphism is a genetic risk factor for URSA.

  5. The positive effects of high-frequency right dorsolateral prefrontal cortex repetitive transcranial magnetic stimulation on memory, correlated with increases in brain metabolites detected by proton magnetic resonance spectroscopy in recently detoxified alcohol-dependent patients.

    PubMed

    Qiao, Jun; Jin, Guixing; Lei, Licun; Wang, Lan; Du, Yaqiang; Wang, Xueyi

    2016-01-01

    To explore the effect of right dorsolateral prefrontal cortex (DLPFC) repetitive transcranial magnetic stimulation (rTMS) on memory, and its correlation with levels of hippocampal brain metabolites detected by proton magnetic resonance spectroscopy ( 1 H-MRS) in recently detoxified alcohol-dependent patients. In this randomized, double-blind sham-controlled trial, alcohol-dependent patients were enrolled and randomized into two groups: the experimental group (rTMS, 10 Hz, on right DLPFC, 20 sessions) and the control group (sham stimulation). Memory function was assessed using Hopkins Verbal Learning Test-Revised (HVLT-R) and Brief Visuospatial Memory Test-Revised (BVMT-R) before and after treatment. 1 H-MRS was used to detect the levels of N -acetyl aspartic acid (NAA), choline (Cho), and creatine (Cr) in bilateral hippocampi before and after treatment. Thirty-eight patients (18 in the experimental group and 20 in the control group) were included in the analyses. The experimental group showed significantly greater changes in HVLT-R, BVMT-R, NAA/Cr, and Cho/Cr after rTMS from baseline than the control group. The percentage change in BVMT-R and HVLT-R correlated with the percentage change in NAA/Cr and Cho/Cr in the right brain. High-frequency right DLPFC rTMS was associated with improvement in memory dysfunction, which is correlated with levels of hippocampal brain metabolites detected by 1 H-MRS in recently detoxified alcohol-dependent patients.

  6. Design and analysis of control system for VCSEL of atomic interference magnetometer

    NASA Astrophysics Data System (ADS)

    Zhang, Xiao-nan; Sun, Xiao-jie; Kou, Jun; Yang, Feng; Li, Jie; Ren, Zhang; Wei, Zong-kang

    2016-11-01

    Magnetic field detection is an important means of deep space environment exploration. Benefit from simple structure and low power consumption, atomic interference magnetometer become one of the most potential detector payloads. Vertical Cavity Surface Emitting Laser (VCSEL) is usually used as a light source in atomic interference magnetometer and its frequency stability directly affects the stability and sensitivity of magnetometer. In this paper, closed-loop control strategy of VCSEL was designed and analysis, the controller parameters were selected and the feedback error algorithm was optimized as well. According to the results of experiments that were performed on the hardware-in-the-loop simulation platform, the designed closed-loop control system is reasonable and it is able to effectively improve the laser frequency stability during the actual work of the magnetometer.

  7. Mutual 3:1 subharmonic synchronization in a micromachined silicon disk resonator

    NASA Astrophysics Data System (ADS)

    Taheri-Tehrani, Parsa; Guerrieri, Andrea; Defoort, Martial; Frangi, Attilio; Horsley, David A.

    2017-10-01

    We demonstrate synchronization between two intrinsically coupled oscillators that are created from two distinct vibration modes of a single micromachined disk resonator. The modes have a 3:1 subharmonic frequency relationship and cubic, non-dissipative electromechanical coupling between the modes enables their two frequencies to synchronize. Our experimental implementation allows the frequency of the lower frequency oscillator to be independently controlled from that of the higher frequency oscillator, enabling study of the synchronization dynamics. We find close quantitative agreement between the experimental behavior and an analytical coupled-oscillator model as a function of the energy in the two oscillators. We demonstrate that the synchronization range increases when the lower frequency oscillator is strongly driven and when the higher frequency oscillator is weakly driven. This result suggests that synchronization can be applied to the frequency-selective detection of weak signals and other mechanical signal processing functions.

  8. Spacecraft dynamics characterization and control system failure detection. Volume 3: Control system failure monitoring

    NASA Technical Reports Server (NTRS)

    Vanschalkwyk, Christiaan M.

    1992-01-01

    We discuss the application of Generalized Parity Relations to two experimental flexible space structures, the NASA Langley Mini-Mast and Marshall Space Flight Center ACES mast. We concentrate on the generation of residuals and make no attempt to implement the Decision Function. It should be clear from the examples that are presented whether it would be possible to detect the failure of a specific component. We derive the equations from Generalized Parity Relations. Two special cases are treated: namely, Single Sensor Parity Relations (SSPR) and Double Sensor Parity Relations (DSPR). Generalized Parity Relations for actuators are also derived. The NASA Langley Mini-Mast and the application of SSPR and DSPR to a set of displacement sensors located at the tip of the Mini-Mast are discussed. The performance of a reduced order model that includes the first five models of the mast is compared to a set of parity relations that was identified on a set of input-output data. Both time domain and frequency domain comparisons are made. The effect of the sampling period and model order on the performance of the Residual Generators are also discussed. Failure detection experiments where the sensor set consisted of two gyros and an accelerometer are presented. The effects of model order and sampling frequency are again illustrated. The detection of actuator failures is discussed. We use Generalized Parity Relations to monitor control system component failures on the ACES mast. An overview is given of the Failure Detection Filter and experimental results are discussed. Conclusions and directions for future research are given.

  9. Optomechanical proposal for monitoring microtubule mechanical vibrations

    NASA Astrophysics Data System (ADS)

    Barzanjeh, Sh.; Salari, V.; Tuszynski, J. A.; Cifra, M.; Simon, C.

    2017-07-01

    Microtubules provide the mechanical force required for chromosome separation during mitosis. However, little is known about the dynamic (high-frequency) mechanical properties of microtubules. Here, we theoretically propose to control the vibrations of a doubly clamped microtubule by tip electrodes and to detect its motion via the optomechanical coupling between the vibrational modes of the microtubule and an optical cavity. In the presence of a red-detuned strong pump laser, this coupling leads to optomechanical-induced transparency of an optical probe field, which can be detected with state-of-the art technology. The center frequency and line width of the transparency peak give the resonance frequency and damping rate of the microtubule, respectively, while the height of the peak reveals information about the microtubule-cavity field coupling. Our method opens the new possibilities to gain information about the physical properties of microtubules, which will enhance our capability to design physical cancer treatment protocols as alternatives to chemotherapeutic drugs.

  10. Induction heating apparatus and methods of operation thereof

    DOEpatents

    Richardson, John G.

    2006-08-01

    Methods of operation of an induction melter include providing material within a cooled crucible proximate an inductor. A desired electromagnetic flux skin depth for heating the material within the crucible may be selected, and a frequency of an alternating current for energizing the inductor and for producing the desired skin depth may be selected. The alternating current frequency may be adjusted after energizing the inductor to maintain the desired electromagnetic flux skin depth. The desired skin depth may be substantially maintained as the temperature of the material varies. An induction heating apparatus includes a sensor configured to detect changes in at least one physical characteristic of a material to be heated in a crucible, and a controller configured for selectively varying a frequency of an alternating current for energizing an inductor at least partially in response to changes in the physical characteristic to be detected by the sensor.

  11. Epstein-Barr virus in oral shedding of children with multiple sclerosis

    PubMed Central

    Yea, Carmen; Tellier, Raymond; Chong, Patrick; Westmacott, Garrett; Marrie, Ruth Ann; Bar-Or, Amit

    2013-01-01

    Objective: To investigate Epstein-Barr virus (EBV) oral shedding frequency and EBV genetic diversity in pediatric patients with multiple sclerosis (MS). Methods: This was a prospective case-control study. We used PCR-based assays to detect viral DNA in the monthly mouth swabs of 22 pediatric patients with MS and 77 age- and sex-matched healthy controls. EBV-positive samples were further analyzed for sequence variation in the EBV BCRF1 (ebvIL-10) gene using direct DNA sequencing methods, and in the EBV LMP1 gene by mass spectrometry. Results: Nineteen of the 22 (86.4%) children with MS were seropositive for remote EBV infection compared to 35 out of 77 (45.5%) healthy controls (p = 0.008). Baseline analysis of mouth swabs revealed a higher proportion of EBV-positive samples from EBV-seropositive patients with MS compared to EBV-seropositive healthy controls (52.6% vs 20%, p = 0.007). Longitudinal analysis of monthly swabs revealed average EBV detection rates of 50.6% in patients with MS and 20.4% in controls (p = 0.01). The oral shedding frequencies of Herpesviruses herpes simplex virus–1, cytomegalovirus, human herpesvirus (HHV)-6, and HHV-7 did not differ between groups. Changes in the predominant EBV genetic variants were detected more frequently in patients with MS; however, no specific EBV genetic variant was preferentially associated with MS. Conclusion: Children with MS demonstrate abnormally increased rates of EBV viral reactivation and a broader range of genetic variants, suggesting a selective impairment in their immunologic control of EBV. PMID:24014504

  12. Compact mobile-reader system for two-way wireless communication, tracking and status monitoring for transport safety and security

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Han-Chung; Liu, Yung Y.; Lee, Hok L.

    A system for monitoring a plurality radio frequency identification tags is described. The system uses at least one set of radio frequency identification tags. Each tag is attached to a container and includes several sensors for detecting physical conditions of said container. The system includes at least one autonomous intermediate reader in wireless communication with the frequency identification tags. The intermediate reader includes external wireless communication system, intermediate reader logic controller, and a self-contained rechargeable power supply. The system uses a central status reporting system in communication the intermediate reader.

  13. The control of the magnetosphere by power line radiation

    NASA Technical Reports Server (NTRS)

    Luette, J. P.; Park, C. G.; Helliwell, R. A.

    1979-01-01

    Evidence is presented that radiated power line harmonics leak into high-altitude regions of the magnetosphere with sufficient intensity to control the starting frequencies of chorus emissions. OGO-3 data from three passes show that the starting frequencies of all measurable chorus emissions were within a few hertz of power line harmonics. It is also found that emissions detected over Western Europe were controlled by harmonics of 50 Hz; over the eastern United States and Canada by 60 Hz; and along the Alaska-New Zealand meridian by harmonics of both 50 and 60 Hz. These results indicate that man-made VLF noise plays an important role in the generation of chorus, one of the commonly observed forms of wave activity in the outer magnetosphere.

  14. The common single-nucleotide polymorphism rs2681472 is associated with early-onset preeclampsia in Northern Han Chinese women.

    PubMed

    Wan, Ji-Peng; Wang, Hong; Li, Chang-Zhong; Zhao, Han; You, Li; Shi, Dong-Hong; Sun, Xiu-Hua; Lv, Hong; Wang, Fei; Wen, Ze-Qing; Wang, Xie-Tong; Chen, Zi-Jiang

    2014-11-01

    Preeclampsia, characterized by hypertension and proteinuria, remains a leading cause of maternal morbidity and mortality. Recently, a genome-wide association study (GWAS) identified the single-nucleotide polymorphism, rs2681472, as a new hypertension susceptibility genetic variant. The purpose of this study was to evaluate the association between preeclampsia and rs268172 in a Northern Han Chinese population. We genotyped 1218 unrelated Northern Han Chinese women, including 515 patients with preeclampsia and 703 healthy controls. No significant differences were detected in the allele frequencies between patients and controls (P = .23). When patients were divided into early-onset and late-onset preeclampsia according to gestational age of disease onset, the allele frequencies significantly differed between controls and patients with early-onset preeclampsia (P = .02). Genotype frequencies also were significantly different between controls and patients early-onset preeclampsia when data were analyzed under additive (P = .03) and dominant (P = .009) models. We replicated this association in an independent Northern Han Chinese population and observed a significant difference in the allele frequencies between patients with early-onset preeclampsia and controls (P = .011). We report that rs2681472 is associated with early-onset preeclampsia in Northern Han Chinese women. © The Author(s) 2014.

  15. Feasibility of vibration monitoring of small rotating machines for the environmental control and life support systems (ECLSS) of the NASA advanced space craft

    NASA Technical Reports Server (NTRS)

    Milner, G. Martin; Black, Mike; Hovenga, Mike; Mcclure, Paul; Miller, Patrice

    1988-01-01

    The application of vibration monitoring to the rotating machinery typical of ECLSS components in advanced NASA spacecraft was studied. It is found that the weighted summation of the accelerometer power spectrum is the most successful detection scheme for a majority of problem types. Other detection schemes studied included high-frequency demodulation, cepstrum, clustering, and amplitude processing.

  16. An atomic magnetometer with autonomous frequency stabilization and large dynamic range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pradhan, S., E-mail: spradhan@barc.gov.in, E-mail: pradhans75@gmail.com; Poornima,; Dasgupta, K.

    2015-06-15

    The operation of a highly sensitive atomic magnetometer using elliptically polarized resonant light is demonstrated. It is based on measurement of zero magnetic field resonance in degenerate two level systems using polarimetric detection. The transmitted light through the polarimeter is used for laser frequency stabilization, whereas reflected light is used for magnetic field measurement. Thus, the experimental geometry allows autonomous frequency stabilization of the laser frequency leading to compact operation of the overall device and has a preliminary sensitivity of <10 pT/Hz{sup 1/2} @ 1 Hz. Additionally, the dynamic range of the device is improved by feedback controlling the biasmore » magnetic field without compromising on its sensitivity.« less

  17. Development of Feedhorn-Coupled Multichroic Polarimeters for the Inflation Probe Mission

    NASA Astrophysics Data System (ADS)

    McMahon, Jeff

    This proposal seeks support for the development of millimeter-wavelength multichroic polarimeters optimized for detecting Cosmic Microwave Background (CMB) polarization signals with a future NASA Inflation Probe Mission. The technologies developed under this proposal would also have applications in future submillimeter astrophysics satellite missions. The proposed technology would increase the overall experimental sensitivity of an Inflation Probe Mission over that achievable by single-frequency pixels, making efficient use of available diffraction-limited focal plane area while maintaining unmatched control over systematics through the use of corrugated feedhorns. The sensitivity, multi-frequency coverage, and control of detector systematics offered by this technology on the Inflation Probe Mission would provide the definitive measurement of CMB polarization and foreground sources. These data would unambiguously detect or rule out all models of Grand Unified Theory (GUT) scale inflation, provide a precise measurement of the sum of the neutrino masses, and enable a wide variety of astrophysical and additional cosmological measurements. Control of systematics and foregrounds are paramount for a successful detection of the faint inflationary signal. Corrugated feedhorns are the gold standard for producing symmetric beams with low cross-polarization. Using ring-loaded slots, they can be designed to exceed one octave in bandwidth, allowing for multiple bands using a single feed. For the optimal characterization and control of foregrounds, approximately 10 bands are needed over a frequency range roughly spanning 40-300 GHz. Our plan is to develop a scalable multichroic architecture with four frequency bands within an octave of bandwidth, which we will then scale to three different frequency ranges, for a total of 12 bands with band centers on a logarithmic scale ranging from 40-288 GHz. At the key frequencies for CMB polarization (100-150 GHz) our proposed detectors achieve a sensitivity equal to 98% of that achieved with 3:1 bandwidth detectors and 85% of the ideal broad-frequency sensitivity, while providing the systematics benefits of using corrugated feedhorns. This work builds on the efforts of the TRUCE collaboration which has successfully developed 150 GHz polarization-sensitive bolometric detectors fabricated at NIST which are now being deployed in multiple CMB polarization experiments, ABS, ACTPol and SPTPol. Work to extend this architecture to realize broad-band multichroic detectors has already begun, using McMahon's startup funds. A prototype detector and ring-loaded corrugated feedhorn operating in both the 90 and 150 GHz bands has been designed, fabricated, and are now being tested. We will build on this work by developing quadruplexers to separate four bands, scaling this design to higher and lower frequencies, and fully optimizing these detectors for space. We will investigate the use of spline- profiled feeds to use at frequencies where corrugated horns are impractical. The broadband planar microwave technology we propose to develop is scalable to both higher and lower frequencies, and can be employed with a number of different detector technologies, including microwave kinetic inductance detectors (MKIDs). The objectives of the proposed work are directly related to the objectives given in the NASA Research Announcement (NRA) Astronomy and Astrophysics Decadal Survey.

  18. Dual-frequency ultrasound for detecting and sizing bubbles.

    PubMed

    Buckey, Jay C; Knaus, Darin A; Alvarenga, Donna L; Kenton, Marc A; Magari, Patrick J

    2005-01-01

    ISS construction and Mars exploration require extensive extravehicular activity (EVA), exposing crewmembers to increased decompression sickness risk. Improved bubble detection technologies could help increase EVA efficiency and safety. Creare Inc. has developed a bubble detection and sizing instrument using dual-frequency ultrasound. The device emits "pump" and "image" signals at two frequencies. The low-frequency pump signal causes an appropriately-sized bubble to resonate. When the image frequency hits a resonating bubble, mixing signals are returned at the sum and difference of the two frequencies. To test the feasibility of transcutaneous intravascular detection, intravascular bubbles in anesthetized swine were produced using agitated saline and decompression stress. Ultrasonic transducers on the chest provided the two frequencies. Mixing signals were detected transthoracically in the right atrium using both methods. A histogram of estimated bubble sizes could be constructed. Bubbles can be detected and sized transthoracically in the right atrium using dual-frequency ultrasound. c2005 Elsevier Ltd. All rights reserved.

  19. Frequency-velocity mismatch: a fundamental abnormality in parkinsonian gait.

    PubMed

    Cho, Catherine; Kunin, Mikhail; Kudo, Koji; Osaki, Yasuhiro; Olanow, C Warren; Cohen, Bernard; Raphan, Theodore

    2010-03-01

    Gait dysfunction and falling are major sources of disability for patients with advanced Parkinson's disease (PD). It is presently thought that the fundamental defect is an inability to generate normal stride length. Our data suggest, however, that the basic problem in PD gait is an impaired ability to match step frequency to walking velocity. In this study, foot movements of PD and normal subjects were monitored with an OPTOTRAK motion-detection system while they walked on a treadmill at different velocities. PD subjects were also paced with auditory stimuli at different frequencies. PD gait was characterized by step frequencies that were faster and stride lengths that were shorter than those of normal controls. At low walking velocities, PD stepping had a reduced or absent terminal toe lift, which truncated swing phases, producing shortened steps. Auditory pacing was not able to normalize step frequency at these lower velocities. Peak forward toe velocities increased with walking velocity and PD subjects could initiate appropriate foot dynamics during initial phases of the swing. They could not control the foot appropriately in terminal phases, however. Increased treadmill velocity, which matched the natural PD step frequency, generated a second toe lift, normalizing step size. Levodopa increased the bandwidth of step frequencies, but was not as effective as increases in walking velocity in normalizing gait. We postulate that the inability to control step frequency and adjust swing phase dynamics to slower walking velocities are major causes for the gait impairment in PD.

  20. Frequency-Velocity Mismatch: A Fundamental Abnormality in Parkinsonian Gait

    PubMed Central

    Kunin, Mikhail; Kudo, Koji; Osaki, Yasuhiro; Olanow, C. Warren; Cohen, Bernard; Raphan, Theodore

    2010-01-01

    Gait dysfunction and falling are major sources of disability for patients with advanced Parkinson's disease (PD). It is presently thought that the fundamental defect is an inability to generate normal stride length. Our data suggest, however, that the basic problem in PD gait is an impaired ability to match step frequency to walking velocity. In this study, foot movements of PD and normal subjects were monitored with an OPTOTRAK motion-detection system while they walked on a treadmill at different velocities. PD subjects were also paced with auditory stimuli at different frequencies. PD gait was characterized by step frequencies that were faster and stride lengths that were shorter than those of normal controls. At low walking velocities, PD stepping had a reduced or absent terminal toe lift, which truncated swing phases, producing shortened steps. Auditory pacing was not able to normalize step frequency at these lower velocities. Peak forward toe velocities increased with walking velocity and PD subjects could initiate appropriate foot dynamics during initial phases of the swing. They could not control the foot appropriately in terminal phases, however. Increased treadmill velocity, which matched the natural PD step frequency, generated a second toe lift, normalizing step size. Levodopa increased the bandwidth of step frequencies, but was not as effective as increases in walking velocity in normalizing gait. We postulate that the inability to control step frequency and adjust swing phase dynamics to slower walking velocities are major causes for the gait impairment in PD. PMID:20042701

  1. [Frequency of cancer in a specialty hospital in Mexico City. Implications for the development of early detection methods].

    PubMed

    Herrera-Torre, Analy; García-Rodríguez, Francisco Mario; García, Rebeca Gil; Jiménez-Villanueva, Xicoténcatl; Hernández-Rubio, Angela; Aboharp-Hasan, Ziad

    2014-01-01

    Cancer is the second cause of death in Mexico. The Juarez Hospital of Mexico is a highly specialized general hospital in which the frequency of cancer treated at the Oncology Unit is a representative sample of the frequency of cancer in the country. To learn about the frequency of presentation of tumors diagnosed in a third level hospital. We reviewed all the biopsies and surgical specimens diagnosed as cancer or malignant tumors registered in the pathology unit during the years 2006 to 2010. We grouped the cases by age, sex, and anatomic site. We identified the 10 most common cancers for both sexes, age groups and sex affected, raising the chances of early detection campaigns reinforce for the most common cancers and try to increase control and cure rates and improve coverage of the economically weak, for their integration into health systems. Information obtained reflects the reality of the country to the general population without entitlements. That in our country women suffer more than men of cancer that breast neoplasms and genital tract are the most frequent, and timely detection systems exist and should be strengthened to achieve greater eligible for early identification of cases in our population.

  2. Regional Cerebral Abnormalities Measured by Frequency-Domain Near-Infrared Spectroscopy in Pediatric Patients During Extracorporeal Membrane Oxygenation.

    PubMed

    Tian, Fenghua; Jenks, Christopher; Potter, Donald; Miles, Darryl; Raman, Lakshmi

    Extracorporeal membrane oxygenation (ECMO) is a form of advanced cardiorespiratory support provided to critically ill patients with severe respiratory or cardiovascular failure. While children undergoing ECMO therapy have significant risk for neurological morbidity, currently there is a lack of reliable bedside tool to detect the neurologic events for patients on ECMO. This study assessed the feasibility of frequency-domain near-infrared spectroscopy (NIRS) for detection of intracranial complications during ECMO therapy. The frequency-domain NIRS device measured the absorption coefficient (µa) and reduced scattering coefficient (µs') at six cranial positions from seven pediatric patients (0-16 years) during ECMO support and five healthy controls (2-14 years). Regional abnormalities in both absorption and scattering were identified among ECMO patients. A main finding in this study is that the abnormalities in scattering appear to be associated with lower-than-normal µs' values in regional areas of the brain. Because light scattering originates from the intracellular structures (such as nuclei and mitochondria), a reduction in scattering primarily reflects loss or decreased density of the brain matter. The results from this study indicate a potential to use the frequency-domain NIRS as a safe and complementary technology for detection of intracranial complications during ECMO therapy.

  3. Biosensing in a microelectrofluidic system using optical whispering-gallery mode spectroscopy

    PubMed Central

    Huang, Lei; Guo, Zhixiong

    2011-01-01

    Label-free detection of biomolecules using an optical whispering-gallery mode sensor in a microelectrofluidic channel is simulated. Negatively charged bovine serum albumin is considered as the model protein analyte. The analyte transport in aqueous solution is controlled by an externally applied electrical field. The finite element method is employed for solving the equations of the charged species transport, the Poisson equation of electric potential, the equations of conservation of momentum and energy, and the Helmholtz equations of electromagnetic waves. The adsorption process of the protein molecules on the microsensor head surface is monitored by the resonance frequency shifts. Frequency shift caused by temperature variation due to Joule heating is analyzed and found to be negligible. The induced shifts behave in a manner similar to Langmuir-like adsorption kinetics; but the time constant increases due to the presence of the external electrical field. A correlation of the frequency shift, the analyte feed concentration in the solution, and the applied voltage gradient is obtained, in which an excellent linear relationship between the frequency shift and the analyte concentration is revealed. The applied voltage gradient enhances significantly the analyte concentration in the vicinity of the sensor surface; thus, the sensor sensitivity which has a power function of the voltage gradient with exponent 2.85 in the controlled voltage range. Simulated detection of extremely low protein concentration to the pico-molar level is carried out. PMID:22662041

  4. Real-time PCR genotyping assay for canine progressive rod-cone degeneration and mutant allele frequency in Toy Poodles, Chihuahuas and Miniature Dachshunds in Japan.

    PubMed

    Kohyama, Moeko; Tada, Naomi; Mitsui, Hiroko; Tomioka, Hitomi; Tsutsui, Toshihiko; Yabuki, Akira; Rahman, Mohammad Mahbubur; Kushida, Kazuya; Mizukami, Keijiro; Yamato, Osamu

    2016-03-01

    Canine progressive rod-cone degeneration (PRCD) is a middle- to late-onset, autosomal recessive, inherited retinal disorder caused by a substitution (c.5G>A) in the canine PRCD gene that has been identified in 29 or more purebred dogs. In the present study, a TaqMan probe-based real-time PCR assay was developed and evaluated for rapid genotyping and large-scale screening of the mutation. Furthermore, a genotyping survey was carried out in a population of the three most popular breeds in Japan (Toy Poodles, Chihuahuas and Miniature Dachshunds) to determine the current mutant allele frequency. The assay separated all the genotypes of canine PRCD rapidly, indicating its suitability for large-scale surveys. The results of the survey showed that the mutant allele frequency in Toy Poodles was high enough (approximately 0.09) to allow the establishment of measures for the prevention and control of this disorder in breeding kennels. The mutant allele was detected in Chihuahuas for the first time, but the frequency was lower (approximately 0.02) than that in Toy Poodles. The mutant allele was not detected in Miniature Dachshunds. This assay will allow the selective breeding of dogs from the two most popular breeds (Toy Poodle and Chihuahua) in Japan and effective prevention or control of the disorder.

  5. Real-time PCR genotyping assay for canine progressive rod-cone degeneration and mutant allele frequency in Toy Poodles, Chihuahuas and Miniature Dachshunds in Japan

    PubMed Central

    KOHYAMA, Moeko; TADA, Naomi; MITSUI, Hiroko; TOMIOKA, Hitomi; TSUTSUI, Toshihiko; YABUKI, Akira; RAHMAN, Mohammad Mahbubur; KUSHIDA, Kazuya; MIZUKAMI, Keijiro; YAMATO, Osamu

    2015-01-01

    Canine progressive rod-cone degeneration (PRCD) is a middle- to late-onset, autosomal recessive, inherited retinal disorder caused by a substitution (c.5G>A) in the canine PRCD gene that has been identified in 29 or more purebred dogs. In the present study, a TaqMan probe-based real-time PCR assay was developed and evaluated for rapid genotyping and large-scale screening of the mutation. Furthermore, a genotyping survey was carried out in a population of the three most popular breeds in Japan (Toy Poodles, Chihuahuas and Miniature Dachshunds) to determine the current mutant allele frequency. The assay separated all the genotypes of canine PRCD rapidly, indicating its suitability for large-scale surveys. The results of the survey showed that the mutant allele frequency in Toy Poodles was high enough (approximately 0.09) to allow the establishment of measures for the prevention and control of this disorder in breeding kennels. The mutant allele was detected in Chihuahuas for the first time, but the frequency was lower (approximately 0.02) than that in Toy Poodles. The mutant allele was not detected in Miniature Dachshunds. This assay will allow the selective breeding of dogs from the two most popular breeds (Toy Poodle and Chihuahua) in Japan and effective prevention or control of the disorder. PMID:26549343

  6. A novel vibration measurement and active control method for a hinged flexible two-connected piezoelectric plate

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Wang, Xian-feng; Zhang, Xian-Min; Liu, Jin-guo

    2018-07-01

    A novel non-contact vibration measurement method using binocular vision sensors is proposed for piezoelectric flexible hinged plate. Decoupling methods of the bending and torsional low frequency vibration on measurement and driving control are investigated, using binocular vision sensors and piezoelectric actuators. A radial basis function neural network controller (RBFNNC) is designed to suppress both the larger and the smaller amplitude vibrations. To verify the non-contact measurement method and the designed controller, an experimental setup of the flexible hinged plate with binocular vision is constructed. Experiments on vibration measurement and control are conducted by using binocular vision sensors and the designed RBFNNC controllers, compared with the classical proportional and derivative (PD) control algorithm. The experimental measurement results demonstrate that the binocular vision sensors can detect the low-frequency bending and torsional vibration effectively. Furthermore, the designed RBF can suppress the bending vibration more quickly than the designed PD controller owing to the adjustment of the RBF control, especially for the small amplitude residual vibrations.

  7. Advances in SAW gas sensors based on the condensate-adsorption effect.

    PubMed

    Liu, Jiuling; Wang, Wen; Li, Shunzhou; Liu, Minghua; He, Shitang

    2011-01-01

    A surface-acoustic-wave (SAW) gas sensor with a low detection limit and fast response for volatile organic compounds (VOCs) based on the condensate-adsorption effect detection is developed. In this sensor a gas chromatography (GC) column acts as the separator element and a dual-resonator oscillator acts as the detector element. Regarding the surface effective permittivity method, the response mechanism analysis, which relates the condensate-adsorption effect, is performed, leading to the sensor performance prediction prior to fabrication. New designs of SAW resonators, which act as feedback of the oscillator, are devised in order to decrease the insertion loss and to achieve single-mode control, resulting in superior frequency stability of the oscillator. Based on the new phase modulation approach, excellent short-term frequency stability (±3 Hz/s) is achieved with the SAW oscillator by using the 500 MHz dual-port resonator as feedback element. In a sensor experiment investigating formaldehyde detection, the implemented SAW gas sensor exhibits an excellent threshold detection limit as low as 0.38 pg.

  8. On the design of a postprocessor for a search for extraterrestrial intelligence /SETI/ system

    NASA Technical Reports Server (NTRS)

    Healy, T. J.; Seeger, C. L.; Stull, M. A.

    1979-01-01

    The design of an on-line postprocessor for a search for extraterrestrial intelligence (SETI) system is described. Signal processing tasks of the postprocessor include: (1) analysis of power level, phase coherence, and state of polarization of single-channel signals in a search for significant signals; (2) grouping or aggregation of adjacent channel data, time averaging of data; and (3) the detection of drifting and modulated signals. Control functions include multichannel spectrum analyzer frequency and clock control, system calibration and selfdiagnostic, control of data flow to and from short-term and long-term (archival) memories, and operation of detection subsystems, such as a visual display and a tunable receiver.

  9. Multi-Frequency Signal Detection Based on Frequency Exchange and Re-Scaling Stochastic Resonance and Its Application to Weak Fault Diagnosis.

    PubMed

    Liu, Jinjun; Leng, Yonggang; Lai, Zhihui; Fan, Shengbo

    2018-04-25

    Mechanical fault diagnosis usually requires not only identification of the fault characteristic frequency, but also detection of its second and/or higher harmonics. However, it is difficult to detect a multi-frequency fault signal through the existing Stochastic Resonance (SR) methods, because the characteristic frequency of the fault signal as well as its second and higher harmonics frequencies tend to be large parameters. To solve the problem, this paper proposes a multi-frequency signal detection method based on Frequency Exchange and Re-scaling Stochastic Resonance (FERSR). In the method, frequency exchange is implemented using filtering technique and Single SideBand (SSB) modulation. This new method can overcome the limitation of "sampling ratio" which is the ratio of the sampling frequency to the frequency of target signal. It also ensures that the multi-frequency target signals can be processed to meet the small-parameter conditions. Simulation results demonstrate that the method shows good performance for detecting a multi-frequency signal with low sampling ratio. Two practical cases are employed to further validate the effectiveness and applicability of this method.

  10. The detectability of high frequency energy at teleseismic and regional distances, 1. Studies of radiation from high-explosive and nuclear cratering events, 2

    NASA Astrophysics Data System (ADS)

    der, Z. A.; Blandford, R. R.

    1981-03-01

    A survey of the literature on short period seismic studies showed that seismic waves of high frequency in the 3-10 Hz range can be observed regularly at both regional and teleseismic distances. These observations show that the low Q values proposed for the long period seismic waves cannot be valid in the short period band. The data indicate that, in the mantle, Q increases with frequency and may be as much as five times higher at 5-10 Hz than in the long period band. Even with the most conservative assumptions, the level of high frequency amplitudes in the teleseismic P waves exceeds that predicted with a constant t*p = 1 sec by a factor of at least 100,000 at and beyond 5 Hz. The apparent Q beta of the lithosphere, which may be largely due to scattering by the small scale inhomogeneities in the crust, also shows an increase with frequency by as much as a factor of four within the 1-10 Hz band. This parameter controls the attenuation and the detectability of seismic waves at regional distances such as Pn, Pg, Su and Lg.

  11. Detecting Mild Traumatic Brain Injury Using Resting State Magnetoencephalographic Connectivity

    PubMed Central

    da Costa, Leodante; Jetly, Rakesh; Pang, Elizabeth W.; Taylor, Margot J.

    2016-01-01

    Accurate means to detect mild traumatic brain injury (mTBI) using objective and quantitative measures remain elusive. Conventional imaging typically detects no abnormalities despite post-concussive symptoms. In the present study, we recorded resting state magnetoencephalograms (MEG) from adults with mTBI and controls. Atlas-guided reconstruction of resting state activity was performed for 90 cortical and subcortical regions, and calculation of inter-regional oscillatory phase synchrony at various frequencies was performed. We demonstrate that mTBI is associated with reduced network connectivity in the delta and gamma frequency range (>30 Hz), together with increased connectivity in the slower alpha band (8–12 Hz). A similar temporal pattern was associated with correlations between network connectivity and the length of time between the injury and the MEG scan. Using such resting state MEG network synchrony we were able to detect mTBI with 88% accuracy. Classification confidence was also correlated with clinical symptom severity scores. These results provide the first evidence that imaging of MEG network connectivity, in combination with machine learning, has the potential to accurately detect and determine the severity of mTBI. PMID:27906973

  12. Different auditory feedback control for echolocation and communication in horseshoe bats.

    PubMed

    Liu, Ying; Feng, Jiang; Metzner, Walter

    2013-01-01

    Auditory feedback from the animal's own voice is essential during bat echolocation: to optimize signal detection, bats continuously adjust various call parameters in response to changing echo signals. Auditory feedback seems also necessary for controlling many bat communication calls, although it remains unclear how auditory feedback control differs in echolocation and communication. We tackled this question by analyzing echolocation and communication in greater horseshoe bats, whose echolocation pulses are dominated by a constant frequency component that matches the frequency range they hear best. To maintain echoes within this "auditory fovea", horseshoe bats constantly adjust their echolocation call frequency depending on the frequency of the returning echo signal. This Doppler-shift compensation (DSC) behavior represents one of the most precise forms of sensory-motor feedback known. We examined the variability of echolocation pulses emitted at rest (resting frequencies, RFs) and one type of communication signal which resembles an echolocation pulse but is much shorter (short constant frequency communication calls, SCFs) and produced only during social interactions. We found that while RFs varied from day to day, corroborating earlier studies in other constant frequency bats, SCF-frequencies remained unchanged. In addition, RFs overlapped for some bats whereas SCF-frequencies were always distinctly different. This indicates that auditory feedback during echolocation changed with varying RFs but remained constant or may have been absent during emission of SCF calls for communication. This fundamentally different feedback mechanism for echolocation and communication may have enabled these bats to use SCF calls for individual recognition whereas they adjusted RF calls to accommodate the daily shifts of their auditory fovea.

  13. Different Auditory Feedback Control for Echolocation and Communication in Horseshoe Bats

    PubMed Central

    Liu, Ying; Feng, Jiang; Metzner, Walter

    2013-01-01

    Auditory feedback from the animal's own voice is essential during bat echolocation: to optimize signal detection, bats continuously adjust various call parameters in response to changing echo signals. Auditory feedback seems also necessary for controlling many bat communication calls, although it remains unclear how auditory feedback control differs in echolocation and communication. We tackled this question by analyzing echolocation and communication in greater horseshoe bats, whose echolocation pulses are dominated by a constant frequency component that matches the frequency range they hear best. To maintain echoes within this “auditory fovea”, horseshoe bats constantly adjust their echolocation call frequency depending on the frequency of the returning echo signal. This Doppler-shift compensation (DSC) behavior represents one of the most precise forms of sensory-motor feedback known. We examined the variability of echolocation pulses emitted at rest (resting frequencies, RFs) and one type of communication signal which resembles an echolocation pulse but is much shorter (short constant frequency communication calls, SCFs) and produced only during social interactions. We found that while RFs varied from day to day, corroborating earlier studies in other constant frequency bats, SCF-frequencies remained unchanged. In addition, RFs overlapped for some bats whereas SCF-frequencies were always distinctly different. This indicates that auditory feedback during echolocation changed with varying RFs but remained constant or may have been absent during emission of SCF calls for communication. This fundamentally different feedback mechanism for echolocation and communication may have enabled these bats to use SCF calls for individual recognition whereas they adjusted RF calls to accommodate the daily shifts of their auditory fovea. PMID:23638137

  14. Development of Acceleration Sensor and Acceleration Evaluation System for Super-Low-Range Frequencies

    NASA Astrophysics Data System (ADS)

    Asano, Shogo; Matsumoto, Hideki

    2001-05-01

    This paper describes the development process for acceleration sensors used on automobiles and an acceleration evaluation system designed specifically for acceleration at super-low-range frequencies. The features of the newly developed sensor are as follows. 1) Original piezo-bimorph design based on a disc-center-fixed structure achieves pyroeffect cancelling and stabilization of sensor characteristics and enables the detection of the acceleration of 0.0009 G at the super-low-range-frequency of 0.03 Hz. 2) The addition of a self-diagnostic function utilizing the characteristics of piezoceramics enables constant monitoring of sensor failure. The frequency range of acceleration for accurate vehicle motion control is considered to be from DC to about 50 Hz. However, the measurement of acceleration in the super-low-range frequency near DC has been difficult because of mechanical and electrical noise interruption. This has delayed the development of the acceleration sensor for automotive use. We have succeeded in the development of an acceleration evaluation system for super-low-range frequencies from 0.015 Hz to 2 Hz with detection of the acceleration range from 0.0002 G (0.2 gal) to 1 G, as well as the development of a piezoelectric-type acceleration sensor for automotive use.

  15. Digital implementation of a laser frequency stabilisation technique in the telecommunications band

    NASA Astrophysics Data System (ADS)

    Jivan, Pritesh; van Brakel, Adriaan; Manuel, Rodolfo Martínez; Grobler, Michael

    2016-02-01

    Laser frequency stabilisation in the telecommunications band was realised using the Pound-Drever-Hall (PDH) error signal. The transmission spectrum of the Fabry-Perot cavity was used as opposed to the traditionally used reflected spectrum. A comparison was done using an analogue as well as a digitally implemented system. This study forms part of an initial step towards developing a portable optical time and frequency standard. The frequency discriminator used in the experimental setup was a fibre-based Fabry-Perot etalon. The phase sensitive system made use of the optical heterodyne technique to detect changes in the phase of the system. A lock-in amplifier was used to filter and mix the input signals to generate the error signal. This error signal may then be used to generate a control signal via a PID controller. An error signal was realised at a wavelength of 1556 nm which correlates to an optical frequency of 1.926 THz. An implementation of the analogue PDH technique yielded an error signal with a bandwidth of 6.134 GHz, while a digital implementation yielded a bandwidth of 5.774 GHz.

  16. Detection and Identification of Translocations by Increased Specific Nondisjunction in ASPERGILLUS NIDULANS

    PubMed Central

    Upshall, Alan; Käfer, Etta

    1974-01-01

    A meiotic technique for visual detection of translocations has been applied to ten mitotically identified interchanges, and three new translocations were discovered using this method. Testcrosses between "standard" strains and potential translocation strains—e.g. strains with newly induced mutants or descendants from translocation crosses—are inspected for the frequency of abnormal-looking colonies. In all heterozygous translocation crosses "abnormals" are increased at least tenfold compared to the average control level of 0.15%. Most of these are disomics, and can be recognized by their characteristic phenotypes. Each translocation produces a few specific types, since nondisjunction is increased mainly in the linkage groups involved in the translocation (50–100-fold over control values). Therefore, translocations were not only detected but often tentatively assigned to linkage groups from the analysis of the disomic progeny in crosses. In addition, this technique allows reciprocal and nonreciprocal translocations to be distinguished, since only the latter produce one-third phenotypically abnormal duplication progeny. While results are clearcut in most cases, occasionally problems are encountered, e.g. when morphological mutants segregate in crosses, or when other genetic factors which increase or reduce the frequency of nondisjunction are present in certain strains. PMID:4594334

  17. Carrier-envelope phase-controlled quantum interference of injected photocurrents in semiconductors.

    PubMed

    Fortier, T M; Roos, P A; Jones, D J; Cundiff, S T; Bhat, R D R; Sipe, J E

    2004-04-09

    We demonstrate quantum interference control of injected photocurrents in a semiconductor using the phase stabilized pulse train from a mode-locked Ti:sapphire laser. Measurement of the comb offset frequency via this technique results in a signal-to-noise ratio of 40 dB (10 Hz resolution bandwidth), enabling solid-state detection of carrier-envelope phase shifts of a Ti:sapphire oscillator.

  18. A Simple Accelerometer Calibrator

    NASA Astrophysics Data System (ADS)

    Salam, R. A.; Islamy, M. R. F.; Munir, M. M.; Latief, H.; Irsyam, M.; Khairurrijal

    2016-08-01

    High possibility of earthquake could lead to the high number of victims caused by it. It also can cause other hazards such as tsunami, landslide, etc. In that case it requires a system that can examine the earthquake occurrence. Some possible system to detect earthquake is by creating a vibration sensor system using accelerometer. However, the output of the system is usually put in the form of acceleration data. Therefore, a calibrator system for accelerometer to sense the vibration is needed. In this study, a simple accelerometer calibrator has been developed using 12 V DC motor, optocoupler, Liquid Crystal Display (LCD) and AVR 328 microcontroller as controller system. The system uses the Pulse Wave Modulation (PWM) form microcontroller to control the motor rotational speed as response to vibration frequency. The frequency of vibration was read by optocoupler and then those data was used as feedback to the system. The results show that the systems could control the rotational speed and the vibration frequencies in accordance with the defined PWM.

  19. Maternal self-efficacy and experimentally manipulated infant difficulty effects on maternal sensory sensitivity: a signal detection analysis.

    PubMed

    Donovan, Wilberta; Leavitt, Lewis; Taylor, Nicole

    2005-09-01

    The impact of differences in maternal self-efficacy and infant difficulty on mothers' sensitivity to small changes in the fundamental frequency of an audiotaped infant's cry was explored in 2 experiments. The experiments share in common experimental manipulations of infant difficulty, a laboratory derived measure of maternal efficacy (low, moderate, and high illusory control), and the use of signal detection methodology to measure maternal sensory sensitivity. In Experiment 1 (N = 72), easy and difficult infant temperament was manipulated by varying the amount of crying (i.e., frequency of cry termination) in a simulated child-care task. In Experiment 2 (N = 51), easy and difficult infant temperament was manipulated via exposure to the solvable or unsolvable pretreatment of a learned helplessness task to mirror mothers' ability to soothe a crying infant. In both experiments, only mothers with high illusory control showed reduced sensory sensitivity under the difficult infant condition compared with the easy infant condition. Copyright 2005 APA, all rights reserved.

  20. Delayed entanglement echo for individual control of a large number of nuclear spins

    PubMed Central

    Wang, Zhen-Yu; Casanova, Jorge; Plenio, Martin B.

    2017-01-01

    Methods to selectively detect and manipulate nuclear spins by single electrons of solid-state defects play a central role for quantum information processing and nanoscale nuclear magnetic resonance (NMR). However, with standard techniques, no more than eight nuclear spins have been resolved by a single defect centre. Here we develop a method that improves significantly the ability to detect, address and manipulate nuclear spins unambiguously and individually in a broad frequency band by using a nitrogen-vacancy (NV) centre as model system. On the basis of delayed entanglement control, a technique combining microwave and radio frequency fields, our method allows to selectively perform robust high-fidelity entangling gates between hardly resolved nuclear spins and the NV electron. Long-lived qubit memories can be naturally incorporated to our method for improved performance. The application of our ideas will increase the number of useful register qubits accessible to a defect centre and improve the signal of nanoscale NMR. PMID:28256508

  1. Delayed entanglement echo for individual control of a large number of nuclear spins.

    PubMed

    Wang, Zhen-Yu; Casanova, Jorge; Plenio, Martin B

    2017-03-03

    Methods to selectively detect and manipulate nuclear spins by single electrons of solid-state defects play a central role for quantum information processing and nanoscale nuclear magnetic resonance (NMR). However, with standard techniques, no more than eight nuclear spins have been resolved by a single defect centre. Here we develop a method that improves significantly the ability to detect, address and manipulate nuclear spins unambiguously and individually in a broad frequency band by using a nitrogen-vacancy (NV) centre as model system. On the basis of delayed entanglement control, a technique combining microwave and radio frequency fields, our method allows to selectively perform robust high-fidelity entangling gates between hardly resolved nuclear spins and the NV electron. Long-lived qubit memories can be naturally incorporated to our method for improved performance. The application of our ideas will increase the number of useful register qubits accessible to a defect centre and improve the signal of nanoscale NMR.

  2. Mutation frequencies of the cytochrome CYP2D6 gene in Parkinson disease patients and in families

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucotte, G.; Turpin, J.C.; Gerard, N.

    1996-07-26

    The frequencies of five mutations of the debrisoquine 4-hydroxylase (CYP2D6) gene (mutations D6-A, B, C, D, and T), corresponding to poor metabolizer (PM) phenotypes, were determined by restriction fragment length polymorphism (RFLP) and polymerase chain reaction (PCR) in 47 patients with Parkinson disease, and compared with the findings in 47 healthy controls. These mutant alleles were about twice as frequent among patients as in controls, with an approximate relative risk ratio of 2.12 (95% confidence interval, 1.41-2.62). There seem to be no significant differences in frequencies of mutant genotypes in patients among gender and modalities of response with levodopa therapy;more » but frequency of the mutations was slightly enhanced after age-at-onset of 60 years. Mutations D6-B, D, and T were detected in 7 patients belonging to 10 Parkinson pedigrees. 25 refs., 1 fig., 2 tabs.« less

  3. High frequency electroporation efficiency is under control of membrane capacitive charging and voltage potential relaxation.

    PubMed

    Novickij, Vitalij; Ruzgys, Paulius; Grainys, Audrius; Šatkauskas, Saulius

    2018-02-01

    The study presents the proof of concept for a possibility to achieve a better electroporation in the MHz pulse repetition frequency (PRF) region compared to the conventional low frequency protocols. The 200ns×10 pulses bursts of 10-14kV/cm have been used to permeabilize Chinese hamster ovary (CHO) cells in a wide range (1Hz-1MHz) of PRF. The permeabilization efficiency was evaluated using fluorescent dye assay (propidium iodide) and flow cytometry. It was determined that a threshold PRF exists when the relaxation of the cell transmembrane potential is longer than the delay between the consequent pulses, which results in accumulation of the charge on the membrane. For the CHO cells and 0.1S/m electroporation medium, this phenomenon is detectable in the 0.5-1MHz range. It was shown that the PRF is an important parameter that could be used for flexible control of electroporation efficiency in the high frequency range. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Application of quality risk management to set viable environmental monitoring frequencies in biotechnology processing and support areas.

    PubMed

    Sandle, Tim

    2012-01-01

    Environmental monitoring programs are essential for pharmaceutical facilities in order to assess the level of environmental control. For biotechnology facilities there is little advice as to the frequency at which viable environmental monitoring should be conducted. This paper outlines an approach, based on the principles of quality risk management, for the development of a framework from which monitoring frequencies can be determined. This involved the identification of common hazards and the evaluation those hazards in terms of the severity of contamination and the probability of contamination occurring. These elements of risk were evaluated for different cleanrooms and the relative risks ranked. Once the risk scores were calculated, the methods for detecting risks within the cleanrooms were assessed. Risk filtering was then used to group different cleanrooms based on their relative risks and detection methods against predetermined monitoring frequencies. Through use of case study examples, the paper presents the model and describes how appropriate frequencies for the environmental monitoring of cleanrooms can be set. Cleanrooms in which biotechnology pharmaceutical processing takes place are subject to environmental monitoring. The frequency at which such monitoring should be performed can be difficult to determine. This paper uses quality risk assessment methods to construct a framework for determining monitoring frequencies and illustrates the suitability of the framework through a case study.

  5. Modeling inter-signal arrival times for accurate detection of CAN bus signal injection attacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Michael Roy; Bridges, Robert A; Combs, Frank L

    Modern vehicles rely on hundreds of on-board electronic control units (ECUs) communicating over in-vehicle networks. As external interfaces to the car control networks (such as the on-board diagnostic (OBD) port, auxiliary media ports, etc.) become common, and vehicle-to-vehicle / vehicle-to-infrastructure technology is in the near future, the attack surface for vehicles grows, exposing control networks to potentially life-critical attacks. This paper addresses the need for securing the CAN bus by detecting anomalous traffic patterns via unusual refresh rates of certain commands. While previous works have identified signal frequency as an important feature for CAN bus intrusion detection, this paper providesmore » the first such algorithm with experiments on five attack scenarios. Our data-driven anomaly detection algorithm requires only five seconds of training time (on normal data) and achieves true positive / false discovery rates of 0.9998/0.00298, respectively (micro-averaged across the five experimental tests).« less

  6. Gastrointestinal symptoms and quality of life in screen-detected celiac disease.

    PubMed

    Paavola, Aku; Kurppa, Kalle; Ukkola, Anniina; Collin, Pekka; Lähdeaho, Marja-Leena; Huhtala, Heini; Mäki, Markku; Kaukinen, Katri

    2012-10-01

    Active serological screening has proved an effective means of increasing the diagnostic rate in celiac disease. The effects of a long-term gluten-free diet on possible gastrointestinal symptoms and psychological well-being in screen-detected patients have nevertheless remained obscure. Abdominal symptoms and quality of life were measured in a large cohort of treated screen-detected celiac adults. Comparisons were made with corresponding symptom-detected patients and with non-celiac controls. Dietary adherence was assessed both by structured interview and by serological testing. In both screen- and symptom-detected celiac groups, 88% of the patients were adherent. On a diet, both screen- and symptom-detected patients reported significantly more gastrointestinal symptoms than non-celiac controls. Those screen-detected patients who reported having no symptoms at the time of diagnosis, also remained asymptomatic during the diet. Despite persistent symptoms, psychological well-being in screen-detected patients was comparable with that in non-celiac controls, whereas the symptom-detected patients showed lower quality of life. Long-term treated screen-detected celiac patients, especially women, suffer from gastrointestinal symptoms on a gluten free diet similarly to symptom-detected patients. However, despite a similar frequency of persistent symptoms, the quality of life was unimpaired in the screen found, but remained low in the symptom-detected group. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  7. Arrays of Individually Controlled Ions Suitable for Two-Dimensional Quantum Simulations (Open Access, Publisher’s Version)

    DTIC Science & Technology

    2016-06-13

    motional ground state, the ratio of Rabi frequencies of carrier and sideband couplings is given by the Lamb-Dicke parameter48, which is for u1 and Dkx...carrier Rabi - frequencies determine Lamb-Dicke parameters and allow for finding the orientation of modes. We use a single ion near T0 to determine the...and find corresponding coefficient settings where we obtain a maximal Rabi rate of the detection transition and/or minimal Rabi rates of micromotion

  8. Pattern-Recognition Algorithm for Locking Laser Frequency

    NASA Technical Reports Server (NTRS)

    Karayan, Vahag; Klipstein, William; Enzer, Daphna; Yates, Philip; Thompson, Robert; Wells, George

    2006-01-01

    A computer program serves as part of a feedback control system that locks the frequency of a laser to one of the spectral peaks of cesium atoms in an optical absorption cell. The system analyzes a saturation absorption spectrum to find a target peak and commands a laser-frequency-control circuit to minimize an error signal representing the difference between the laser frequency and the target peak. The program implements an algorithm consisting of the following steps: Acquire a saturation absorption signal while scanning the laser through the frequency range of interest. Condition the signal by use of convolution filtering. Detect peaks. Match the peaks in the signal to a pattern of known spectral peaks by use of a pattern-recognition algorithm. Add missing peaks. Tune the laser to the desired peak and thereafter lock onto this peak. Finding and locking onto the desired peak is a challenging problem, given that the saturation absorption signal includes noise and other spurious signal components; the problem is further complicated by nonlinearity and shifting of the voltage-to-frequency correspondence. The pattern-recognition algorithm, which is based on Hausdorff distance, is what enables the program to meet these challenges.

  9. Correlation between systemic lupus erythematosus and cytomegalovirus infection detected by different methods.

    PubMed

    Chen, Jing; Zhang, Huidi; Chen, Peirong; Lin, Qiaoai; Zhu, Xiaochun; Zhang, Lifang; Xue, Xiangyang

    2015-04-01

    Human cytomegalovirus (HCMV), a β-herpes virus subfamily member, leads to a lifelong, latent infection in most humans, but the correlation between HCMV infection and systemic lupus erythematosus (SLE) remains controversial. We analyzed the relevance of HCMV infection in SLE by analyzing the peripheral blood leukocytes (PBLs) and serum samples of 60 patients with SLE and 111 healthy individuals. HCMV genes UL55 and UL138 were detected in PBLs by polymerase chain reaction (PCR), and HCMV-specific serum IgG and IgM antibodies were investigated by enzyme-linked immunosorbent assay. The relationship between cellular HCMV infection in PBLs and common clinical indicators of SLE was further explored. Data indicated that the frequency of positive IgG and IgM anti-CMV antibodies was not significantly different in SLE patients and controls. However, compared to the healthy controls, the titers of IgG and IgM anti-CMV antibodies in SLE patients were significantly higher. The detection of cellular HCMV infection showed that almost all subjects were positive for UL138 gene in PBLs, but the positivity for UL55 gene was lower in PBLs. HCMV UL138 detection in PBLs was highly consistent with the frequency of the HCMV-specific IgG test and did not show significant difference in SLE patients and healthy controls. However, compared with that in healthy people, the positivity rate for cellular HCMV UL55 detection was significantly higher in SLE patients (P < 0.001). In addition, cellular HCMV UL55 with positive detection in PBLs was associated with significantly different clinical characteristics of SLE than that with negative detection. In conclusion, our data confirmed that the HCMV infection was related to the development of SLE. Especially, some clinical strains or substrains of HCMV, such as containing the UL55 gene in HCMV's genome, might play a vital role in the development of SLE.

  10. Detecting an atomic clock frequency anomaly using an adaptive Kalman filter algorithm

    NASA Astrophysics Data System (ADS)

    Song, Huijie; Dong, Shaowu; Wu, Wenjun; Jiang, Meng; Wang, Weixiong

    2018-06-01

    The abnormal frequencies of an atomic clock mainly include frequency jump and frequency drift jump. Atomic clock frequency anomaly detection is a key technique in time-keeping. The Kalman filter algorithm, as a linear optimal algorithm, has been widely used in real-time detection for abnormal frequency. In order to obtain an optimal state estimation, the observation model and dynamic model of the Kalman filter algorithm should satisfy Gaussian white noise conditions. The detection performance is degraded if anomalies affect the observation model or dynamic model. The idea of the adaptive Kalman filter algorithm, applied to clock frequency anomaly detection, uses the residuals given by the prediction for building ‘an adaptive factor’ the prediction state covariance matrix is real-time corrected by the adaptive factor. The results show that the model error is reduced and the detection performance is improved. The effectiveness of the algorithm is verified by the frequency jump simulation, the frequency drift jump simulation and the measured data of the atomic clock by using the chi-square test.

  11. Research on the relativity between gene polymorphism and children cardiac insufficiency.

    PubMed

    He, X-H; Li, C-L; Ling, N; Wang, Q-W; Wang, Z-Z; An, X-J

    2017-08-01

    We analyzed the relationship between Mink-S27 gene polymorphism and children with cardiac insufficiency. From April 2013 to April 2015, we enrolled 73 cases of children with cardiac insufficiency for this study, and all 73 were placed in the observation group. 76 normal cases were selected for the control group. Restriction fragment length polymorphism (RFLP) was used to make polymorphism analysis of the Mink-S27. Our results showed no significant differences in Mink-S27 genotype and allele distribution in both observation and control groups (p>0.05). In lesion samples collected from children with cardiac insufficiency, we detected significant difference in AA, CC genotype frequency and allele frequency between the observation group and the control group (p< 0.05) (X2 = 15.43, p<0.05; X2  = 16.27, p<0.05). Further studies on samples obtained from both groups revealed certain differences of AA, CC, AC genotype frequency and allele frequency in the observation group. The proportion of homozygote (AA, CC) in children with severe cardiac insufficiency was relatively high. GNAS2 gene polymorphism was associated with the prevalence of cardiac insufficiency in children. And also the patients' condition was correlated to the frequency of different genotypes and alleles.

  12. Impact of the 4G/5G polymorphism in the plasminogen activator inhibitor-1 gene on primary nephrotic syndrome.

    PubMed

    Luo, Yuezhong; Wang, Chao; Tu, Haitao

    2014-03-01

    The aim of the present study was to investigate whether the four guanosines (4G)/five guanosines (5G) polymorphism in the gene coding for plasminogen activator inhibitor-1 (PAI-1) affects the clinical features of primary nephrotic syndrome (PNS). A cohort of 200 biopsy-diagnosed PNS patients was studied, with 40 healthy subjects as controls. The PAI-1 gene polymorphism was detected by polymerase chain reaction and DNA sequencing. Associations between the PAI-1 4G/5G polymorphism and clinical features and pathological types of PNS were analyzed. The results indicated that the PAI-1 genotype distribution is significantly different between patients with PNS and healthy controls, with significantly higher numbers of the 4G/4G genotype and lower numbers of the 5G5G genotype detected in PNS patients compared to controls (both P<0.05). The frequency of the 4G allele was also significantly higher in PNS patients compared to healthy controls (P<0.01). Among the different pathological types of PNS, IgA nephropathy (IgAN) and membranous nephropathy (MN) were associated with significantly increased frequencies of the 4G/4G and 4G/5G genotypes, as well as of the 4G allele. The increased 4G frequency was also detected in patients with minimal change disease (MCD). Significantly increased international normalized ratio (INR) and prolonged activated partial thromboplastin time (APTT) were observed in 4G/4G compared to 5G/5G PNS subjects. The response to steroids was not significantly different among the three genotypes. In conclusion, the 4G allele of the PAI-1 gene appears to be associated with PNS, especially in MN and IgAN patients. These findings suggest that specific targeting may be required for the treatment of PNS patients with the 4G/4G genotype.

  13. Frequency-dependent baroreflex control of blood pressure and heart rate during physical exercise.

    PubMed

    Spadacini, Giammario; Passino, Claudio; Leuzzi, Stefano; Valle, Felice; Piepoli, Massimo; Calciati, Alessandro; Sleight, Peter; Bernardi, Luciano

    2006-02-15

    It is widely recognised that during exercise vagal heart rate control is markedly impaired but blood pressure control may or may not be retained. We hypothesised that this uncertainty arose from the differing responses of the vagus (fast) and sympathetic (slow) arms of the autonomic effectors, and to differing sympatho-vagal balance at different exercise intensities. We studied 12 normals at rest, during moderate (50% maximal heart rate) and submaximal (80% maximal heart rate) exercise. The carotid baroreceptors were stimulated by sinusoidal neck suction at the frequency of the spontaneous high- (during moderate exercise) and low-frequency (during submaximal) fluctuations in heart period and blood pressure. The increases in these oscillations induced by neck suction were measured by autoregressive spectral analysis. At rest neck stimulation increased variability at low frequency (RR: from 6.99+/-0.24 to 8.87+/-0.18 ln-ms2; systolic pressure: from 3.05+/-1.7 to 4.09+/-0.17 ln-mm Hg2) and high frequency (RR: from 4.67+/-0.25 to 6.79+/-0.31 ln-ms2; systolic pressure: from 1.93+/-0.2 to 2.67+/-0.125 ln-mm Hg2) (all p<0.001). During submaximal exercise RR variability decreased but systolic pressure variability rose (p<0.01 vs rest); during submaximal exercise low-frequency neck stimulation increased the low-frequency fluctuations in blood pressure (2.35+/-0.51 to 4.25+/-0.38 ln-mm Hg2, p<0.05) and RR. Conversely, neck suction at high frequency was ineffective on systolic pressure, and had only minor effects on RR interval during moderate exercise. During exercise baroreflex control is active on blood pressure, but the efferent response on blood pressure and heart rate is only detected during low frequency stimulation, indicating a frequency-dependent effect.

  14. Scalable digital hardware for a trapped ion quantum computer

    NASA Astrophysics Data System (ADS)

    Mount, Emily; Gaultney, Daniel; Vrijsen, Geert; Adams, Michael; Baek, So-Young; Hudek, Kai; Isabella, Louis; Crain, Stephen; van Rynbach, Andre; Maunz, Peter; Kim, Jungsang

    2016-12-01

    Many of the challenges of scaling quantum computer hardware lie at the interface between the qubits and the classical control signals used to manipulate them. Modular ion trap quantum computer architectures address scalability by constructing individual quantum processors interconnected via a network of quantum communication channels. Successful operation of such quantum hardware requires a fully programmable classical control system capable of frequency stabilizing the continuous wave lasers necessary for loading, cooling, initialization, and detection of the ion qubits, stabilizing the optical frequency combs used to drive logic gate operations on the ion qubits, providing a large number of analog voltage sources to drive the trap electrodes, and a scheme for maintaining phase coherence among all the controllers that manipulate the qubits. In this work, we describe scalable solutions to these hardware development challenges.

  15. Multi-Frequency Signal Detection Based on Frequency Exchange and Re-Scaling Stochastic Resonance and Its Application to Weak Fault Diagnosis

    PubMed Central

    Leng, Yonggang; Fan, Shengbo

    2018-01-01

    Mechanical fault diagnosis usually requires not only identification of the fault characteristic frequency, but also detection of its second and/or higher harmonics. However, it is difficult to detect a multi-frequency fault signal through the existing Stochastic Resonance (SR) methods, because the characteristic frequency of the fault signal as well as its second and higher harmonics frequencies tend to be large parameters. To solve the problem, this paper proposes a multi-frequency signal detection method based on Frequency Exchange and Re-scaling Stochastic Resonance (FERSR). In the method, frequency exchange is implemented using filtering technique and Single SideBand (SSB) modulation. This new method can overcome the limitation of "sampling ratio" which is the ratio of the sampling frequency to the frequency of target signal. It also ensures that the multi-frequency target signals can be processed to meet the small-parameter conditions. Simulation results demonstrate that the method shows good performance for detecting a multi-frequency signal with low sampling ratio. Two practical cases are employed to further validate the effectiveness and applicability of this method. PMID:29693577

  16. Increased peripheral blood CD4+ T cell responses to deamidated but not to native gliadin in children with coeliac disease

    PubMed Central

    Lammi, A; Arikoski, P; Vaarala, O; Kinnunen, T; Ilonen, J

    2012-01-01

    T cell recognition of gliadin from dietary gluten is essential for the pathogenesis of coeliac disease (CD). The aim of the present study was to analyse whether gliadin-specific T cells are detectable in the circulation of children with newly diagnosed coeliac disease by using a sensitive carboxfluorescein diacetate succinimidyl ester (CFSE) dilution method. Peripheral blood CD4+ T cell responses were analysed in 20 children at diagnosis of CD and compared to those in 64 healthy control children carrying the CD-associated human leucocyte antigen (HLA)-DQ2 or -DQ8 alleles. Deamidated gliadin (gTG)-specific T cells were detectable in the peripheral blood of more than half the children with CD (11 of 20, 55%) compared to 15 of 64 (23·4%) of the control children (P = 0·008). Proliferative responses to gTG were also significantly stronger in children with CD than in controls (P = 0·01). In contrast, T cells specific to native gliadin were detectable at comparable frequencies in children with CD (two of 19, 10·5%) and controls (13 of 64, 20·3%). gTG-specific T cells had a memory phenotype more often than those specific to native gliadin in children with CD (P = 0·02), whereas controls had similar percentages of memory cells in both stimulations. Finally, gTG-specific CD4+ T cells had a higher expression of the gut-homing molecule β7 integrin than those specific to the control antigen tetanus toxoid. Collectively, our current results demonstrate that the frequency of circulating memory CD4+ T cells specific to gTG but not native gliadin is increased in children with newly diagnosed CD. PMID:22471282

  17. Increased peripheral blood CD4+ T cell responses to deamidated but not to native gliadin in children with coeliac disease.

    PubMed

    Lammi, A; Arikoski, P; Vaarala, O; Kinnunen, T; Ilonen, J

    2012-05-01

    T cell recognition of gliadin from dietary gluten is essential for the pathogenesis of coeliac disease (CD). The aim of the present study was to analyse whether gliadin-specific T cells are detectable in the circulation of children with newly diagnosed coeliac disease by using a sensitive carboxfluorescein diacetate succinimidyl ester (CFSE) dilution method. Peripheral blood CD4(+) T cell responses were analysed in 20 children at diagnosis of CD and compared to those in 64 healthy control children carrying the CD-associated human leucocyte antigen (HLA)-DQ2 or -DQ8 alleles. Deamidated gliadin (gTG)-specific T cells were detectable in the peripheral blood of more than half the children with CD (11 of 20, 55%) compared to 15 of 64 (23.4%) of the control children (P = 0.008). Proliferative responses to gTG were also significantly stronger in children with CD than in controls (P = 0.01). In contrast, T cells specific to native gliadin were detectable at comparable frequencies in children with CD (two of 19, 10.5%) and controls (13 of 64, 20.3%). gTG-specific T cells had a memory phenotype more often than those specific to native gliadin in children with CD (P = 0.02), whereas controls had similar percentages of memory cells in both stimulations. Finally, gTG-specific CD4(+) T cells had a higher expression of the gut-homing molecule β7 integrin than those specific to the control antigen tetanus toxoid. Collectively, our current results demonstrate that the frequency of circulating memory CD4(+) T cells specific to gTG but not native gliadin is increased in children with newly diagnosed CD. © 2012 The Authors;Clinical and Experimental Immunology © 2012 British Society for Immunology.

  18. FRF-based structural damage detection of controlled buildings with podium structures: Experimental investigation

    NASA Astrophysics Data System (ADS)

    Xu, Y. L.; Huang, Q.; Zhan, S.; Su, Z. Q.; Liu, H. J.

    2014-06-01

    How to use control devices to enhance system identification and damage detection in relation to a structure that requires both vibration control and structural health monitoring is an interesting yet practical topic. In this study, the possibility of using the added stiffness provided by control devices and frequency response functions (FRFs) to detect damage in a building complex was explored experimentally. Scale models of a 12-storey main building and a 3-storey podium structure were built to represent a building complex. Given that the connection between the main building and the podium structure is most susceptible to damage, damage to the building complex was experimentally simulated by changing the connection stiffness. To simulate the added stiffness provided by a semi-active friction damper, a steel circular ring was designed and used to add the related stiffness to the building complex. By varying the connection stiffness using an eccentric wheel excitation system and by adding or not adding the circular ring, eight cases were investigated and eight sets of FRFs were measured. The experimental results were used to detect damage (changes in connection stiffness) using a recently proposed FRF-based damage detection method. The experimental results showed that the FRF-based damage detection method could satisfactorily locate and quantify damage.

  19. Impaired circulating CD4+ LAP+ regulatory T cells in patients with acute coronary syndrome and its mechanistic study.

    PubMed

    Zhu, Zheng-Feng; Meng, Kai; Zhong, Yu-Cheng; Qi, Liang; Mao, Xiao-Bo; Yu, Kun-Wu; Zhang, Wei; Zhu, Peng-Fei; Ren, Ze-Peng; Wu, Bang-Wei; Ji, Qin-Wei; Wang, Xiang; Zeng, Qiu-Tang

    2014-01-01

    CD4(+) latency-associated peptide (LAP)(+) regulatory T cells (Tregs) are a newly discovered T cell subset in humans and the role of these cells in patients with acute coronary syndrome (ACS) has not been explored. We designed to investigate whether circulating frequency and function of CD4(+)LAP(+) Tregs are defective in ACS. One hundred eleven ACS patients (acute myocardial infarction and unstable angina) and 117 control patients were enrolled in the study. The control patients consisted of chronic stable angina (CSA) and chest pain syndrome (CPS). The frequencies of circulating CD4(+)LAP(+) Tregs and the expression of the transmembrane protein glycoprotein-A repetitions predominant (GARP) on CD4(+) T cells were determined by flow cytometry. The function of CD4(+)LAP(+) Tregs was detected using thymidine uptake. Serum interleukin-10 (IL-10) and transforming growth factor-β protein (TGF-β) levels were detected using ELISA and expression of GARP mRNA in peripheral blood mononuclear cells (PBMCs) was measured by real time-polymerase chain reaction. We found ACS patients had a significantly lower frequency of circulating CD4(+)LAP(+) Tregs, and the function of these cells was reduced compared to controls. The expression of GARP in CD4(+) T cells and the serum levels of TGF-β in ACS patients were lower than those of control patients. The serum levels of IL-10 were similar between the two cohorts. A novel regulatory T cell subset, defined as CD4(+)LAP(+) T cells is defective in ACS patients.

  20. Fault detection and diagnosis for refrigerator from compressor sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keres, Stephen L.; Gomes, Alberto Regio; Litch, Andrew D.

    A refrigerator, a sealed refrigerant system, and method are provided where the refrigerator includes at least a refrigerated compartment and a sealed refrigerant system including an evaporator, a compressor, a condenser, a controller, an evaporator fan, and a condenser fan. The method includes monitoring a frequency of the compressor, and identifying a fault condition in the at least one component of the refrigerant sealed system in response to the compressor frequency. The method may further comprise calculating a compressor frequency rate based upon the rate of change of the compressor frequency, wherein a fault in the condenser fan is identifiedmore » if the compressor frequency rate is positive and exceeds a condenser fan fault threshold rate, and wherein a fault in the evaporator fan is identified if the compressor frequency rate is negative and exceeds an evaporator fan fault threshold rate.« less

  1. Unconditional analyses can increase efficiency in assessing gene-environment interaction of the case-combined-control design.

    PubMed

    Goldstein, Alisa M; Dondon, Marie-Gabrielle; Andrieu, Nadine

    2006-08-01

    A design combining both related and unrelated controls, named the case-combined-control design, was recently proposed to increase the power for detecting gene-environment (GxE) interaction. Under a conditional analytic approach, the case-combined-control design appeared to be more efficient and feasible than a classical case-control study for detecting interaction involving rare events. We now propose an unconditional analytic strategy to further increase the power for detecting gene-environment (GxE) interactions. This strategy allows the estimation of GxE interaction and exposure (E) main effects under certain assumptions (e.g. no correlation in E between siblings and the same exposure frequency in both control groups). Only the genetic (G) main effect cannot be estimated because it is biased. Using simulations, we show that unconditional logistic regression analysis is often more efficient than conditional analysis for detecting GxE interaction, particularly for a rare gene and strong effects. The unconditional analysis is also at least as efficient as the conditional analysis when the gene is common and the main and joint effects of E and G are small. Under the required assumptions, the unconditional analysis retains more information than does the conditional analysis for which only discordant case-control pairs are informative leading to more precise estimates of the odds ratios.

  2. Radio Frequency Based Programmable Logic Controller Anomaly Detection

    DTIC Science & Technology

    2013-09-01

    include wireless radios, IEEE 802.15 Blue- tooth devices, cellular phones, and IEEE 802.11 WiFi networking devices. While wireless communication...MacKenzie, H. Shamoon Malware and SCADA Security What are the Im- pacts? . Technical Report, Tofino Security, Sep 2012. 61. Mateti,P. Hacking Techniques

  3. SPERM COUNT, MORPHOLOGY AND FLUORESCENT BODY FREQUENCY IN AUTOPSY SERVICE WORKERS EXPOSED TO FORMALDEHYDE

    EPA Science Inventory

    The ability of a battery of genetic monitoring tests to detect occupational formaldehyde exposure in a population of a hospital autopsy service workers was investigated. Eleven exposed individuals and 11 matched controls were evaluated for sperm count, abnormal sperm morphology a...

  4. Methods of automated absence seizure detection, interference by stimulation, and possibilities for prediction in genetic absence models.

    PubMed

    van Luijtelaar, Gilles; Lüttjohann, Annika; Makarov, Vladimir V; Maksimenko, Vladimir A; Koronovskii, Alexei A; Hramov, Alexander E

    2016-02-15

    Genetic rat models for childhood absence epilepsy have become instrumental in developing theories on the origin of absence epilepsy, the evaluation of new and experimental treatments, as well as in developing new methods for automatic seizure detection, prediction, and/or interference of seizures. Various methods for automated off and on-line analyses of ECoG in rodent models are reviewed, as well as data on how to interfere with the spike-wave discharges by different types of invasive and non-invasive electrical, magnetic, and optical brain stimulation. Also a new method for seizure prediction is proposed. Many selective and specific methods for off- and on-line spike-wave discharge detection seem excellent, with possibilities to overcome the issue of individual differences. Moreover, electrical deep brain stimulation is rather effective in interrupting ongoing spike-wave discharges with low stimulation intensity. A network based method is proposed for absence seizures prediction with a high sensitivity but a low selectivity. Solutions that prevent false alarms, integrated in a closed loop brain stimulation system open the ways for experimental seizure control. The presence of preictal cursor activity detected with state of the art time frequency and network analyses shows that spike-wave discharges are not caused by sudden and abrupt transitions but that there are detectable dynamic events. Their changes in time-space-frequency characteristics might yield new options for seizure prediction and seizure control. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. An integration time adaptive control method for atmospheric composition detection of occultation

    NASA Astrophysics Data System (ADS)

    Ding, Lin; Hou, Shuai; Yu, Fei; Liu, Cheng; Li, Chao; Zhe, Lin

    2018-01-01

    When sun is used as the light source for atmospheric composition detection, it is necessary to image sun for accurate identification and stable tracking. In the course of 180 second of the occultation, the magnitude of sun light intensity through the atmosphere changes greatly. It is nearly 1100 times illumination change between the maximum atmospheric and the minimum atmospheric. And the process of light change is so severe that 2.9 times per second of light change can be reached. Therefore, it is difficult to control the integration time of sun image camera. In this paper, a novel adaptive integration time control method for occultation is presented. In this method, with the distribution of gray value in the image as the reference variable, and the concepts of speed integral PID control, the integration time adaptive control problem of high frequency imaging. The large dynamic range integration time automatic control in the occultation can be achieved.

  6. Automatic seizure detection in SEEG using high frequency activities in wavelet domain.

    PubMed

    Ayoubian, L; Lacoma, H; Gotman, J

    2013-03-01

    Existing automatic detection techniques show high sensitivity and moderate specificity, and detect seizures a relatively long time after onset. High frequency (80-500 Hz) activity has recently been shown to be prominent in the intracranial EEG of epileptic patients but has not been used in seizure detection. The purpose of this study is to investigate if these frequencies can contribute to seizure detection. The system was designed using 30 h of intracranial EEG, including 15 seizures in 15 patients. Wavelet decomposition, feature extraction, adaptive thresholding and artifact removal were employed in training data. An EMG removal algorithm was developed based on two features: Lack of correlation between frequency bands and energy-spread in frequency. Results based on the analysis of testing data (36 h of intracranial EEG, including 18 seizures) show a sensitivity of 72%, a false detection of 0.7/h and a median delay of 5.7 s. Missed seizures originated mainly from seizures with subtle or absent high frequencies or from EMG removal procedures. False detections were mainly due to weak EMG or interictal high frequency activities. The system performed sufficiently well to be considered for clinical use, despite the exclusive use of frequencies not usually considered in clinical interpretation. High frequencies have the potential to contribute significantly to the detection of epileptic seizures. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  7. Automatic seizure detection in SEEG using high frequency activities in wavelet domain

    PubMed Central

    Ayoubian, L.; Lacoma, H.; Gotman, J.

    2015-01-01

    Existing automatic detection techniques show high sensitivity and moderate specificity, and detect seizures a relatively long time after onset. High frequency (80–500 Hz) activity has recently been shown to be prominent in the intracranial EEG of epileptic patients but has not been used in seizure detection. The purpose of this study is to investigate if these frequencies can contribute to seizure detection. The system was designed using 30 h of intracranial EEG, including 15 seizures in 15 patients. Wavelet decomposition, feature extraction, adaptive thresholding and artifact removal were employed in training data. An EMG removal algorithm was developed based on two features: Lack of correlation between frequency bands and energy-spread in frequency. Results based on the analysis of testing data (36 h of intracranial EEG, including 18 seizures) show a sensitivity of 72%, a false detection of 0.7/h and a median delay of 5.7 s. Missed seizures originated mainly from seizures with subtle or absent high frequencies or from EMG removal procedures. False detections were mainly due to weak EMG or interictal high frequency activities. The system performed sufficiently well to be considered for clinical use, despite the exclusive use of frequencies not usually considered in clinical interpretation. High frequencies have the potential to contribute significantly to the detection of epileptic seizures. PMID:22647836

  8. Insecticide resistance of Anopheles sinensis and An. vagus in Hainan Island, a malaria-endemic area of China.

    PubMed

    Qin, Qian; Li, Yiji; Zhong, Daibin; Zhou, Ning; Chang, Xuelian; Li, Chunyuan; Cui, Liwang; Yan, Guiyun; Chen, Xiao-Guang

    2014-03-03

    Malaria is one of the most important public health problems in Southeast Asia, including Hainan Island, China. Vector control is the main malaria control measure, and insecticide resistance is a major concern for the effectiveness of chemical insecticide control programs. The objective of this study is to determine the resistance status of the main malaria vector species to pyrethroids and other insecticides recommended by the World Health Organization (WHO) for indoor residual sprays. The larvae and pupae of Anopheles mosquitoes were sampled from multiple sites in Hainan Island, and five sites yielded sufficient mosquitoes for insecticide susceptibility bioassays. Bioassays of female adult mosquitoes three days after emergence were conducted in the two most abundant species, Anopheles sinensis and An. vagus, using three insecticides (0.05% deltamethrin, 4% DDT, and 5% malathion) and following the WHO standard tube assay procedure. P450 monooxygenase, glutathione S-transferase and carboxylesterase activities were measured. Mutations at the knockdown resistance (kdr) gene and the ace-1 gene were detected by DNA sequencing and PCR-RFLP analysis, respectively. An. sinensis and An. vagus were the predominant Anopheles mosquito species. An. sinensis was found to be resistant to DDT and deltamethrin. An. vagus was susceptible to deltamethrin but resistant to DDT and malathion. Low kdr mutation (L1014F) frequency (<10%) was detected in An. sinensis, but no kdr mutation was detected in An. vagus populations. Modest to high (45%-75%) ace-1 mutation frequency was found in An. sinensis populations, but no ace-1 mutation was detected in An. vagus populations. Significantly higher P450 monooxygenase and carboxylesterase activities were detected in deltamethrin-resistant An. sinensis, and significantly higher P450 monooxygenase, glutathione S-transferase and carboxylesterase activities were found in malathion-resistant An. vagus mosquitoes. Multiple insecticide resistance was found in An. sinensis and An. vagus in Hainan Island, a malaria-endemic area of China. Cost-effective integrated vector control programs that go beyond synthetic insecticides are urgently needed.

  9. Design of temperature detection device for drum of belt conveyor

    NASA Astrophysics Data System (ADS)

    Zhang, Li; He, Rongjun

    2018-03-01

    For difficult wiring and big measuring error existed in the traditional temperature detection method for drum of belt conveyor, a temperature detection device for drum of belt conveyor based on Radio Frequency(RF) communication is designed. In the device, detection terminal can collect temperature data through tire pressure sensor chip SP370 which integrates temperature detection and RF emission. The receiving terminal which is composed of RF receiver chip and microcontroller receives the temperature data and sends it to Controller Area Network(CAN) bus. The test results show that the device meets requirements of field application with measuring error ±3.73 ° and single button battery can provide continuous current for the detection terminal over 1.5 years.

  10. Optimising 4-D surface change detection: an approach for capturing rockfall magnitude-frequency

    NASA Astrophysics Data System (ADS)

    Williams, Jack G.; Rosser, Nick J.; Hardy, Richard J.; Brain, Matthew J.; Afana, Ashraf A.

    2018-02-01

    We present a monitoring technique tailored to analysing change from near-continuously collected, high-resolution 3-D data. Our aim is to fully characterise geomorphological change typified by an event magnitude-frequency relationship that adheres to an inverse power law or similar. While recent advances in monitoring have enabled changes in volume across more than 7 orders of magnitude to be captured, event frequency is commonly assumed to be interchangeable with the time-averaged event numbers between successive surveys. Where events coincide, or coalesce, or where the mechanisms driving change are not spatially independent, apparent event frequency must be partially determined by survey interval.The data reported have been obtained from a permanently installed terrestrial laser scanner, which permits an increased frequency of surveys. Surveying from a single position raises challenges, given the single viewpoint onto a complex surface and the need for computational efficiency associated with handling a large time series of 3-D data. A workflow is presented that optimises the detection of change by filtering and aligning scans to improve repeatability. An adaptation of the M3C2 algorithm is used to detect 3-D change to overcome data inconsistencies between scans. Individual rockfall geometries are then extracted and the associated volumetric errors modelled. The utility of this approach is demonstrated using a dataset of ˜ 9 × 103 surveys acquired at ˜ 1 h intervals over 10 months. The magnitude-frequency distribution of rockfall volumes generated is shown to be sensitive to monitoring frequency. Using a 1 h interval between surveys, rather than 30 days, the volume contribution from small (< 0.1 m3) rockfalls increases from 67 to 98 % of the total, and the number of individual rockfalls observed increases by over 3 orders of magnitude. High-frequency monitoring therefore holds considerable implications for magnitude-frequency derivatives, such as hazard return intervals and erosion rates. As such, while high-frequency monitoring has potential to describe short-term controls on geomorphological change and more realistic magnitude-frequency relationships, the assessment of longer-term erosion rates may be more suited to less-frequent data collection with lower accumulative errors.

  11. Self-seeded single-frequency solid-state ring laser and system using same

    DOEpatents

    Dane, C. Brent; Hackel, Lloyd; Harris, Fritz B.

    2007-02-20

    A method of operating a laser to obtain an output pulse having a single wavelength, comprises inducing an intracavity loss into a laser resonator having an amount that prevents oscillation during a time that energy from the pump source is being stored in the gain medium. Gain is built up in the gain medium with energy from the pump source until formation of a single-frequency relaxation oscillation pulse in the resonator. Upon detection of the onset of the relaxation oscillation pulse, the intracavity loss is reduced, such as by Q-switching, so that the built-up gain stored in the gain medium is output from the resonator in the form of an output pulse at a single frequency. An electronically controllable output coupler is controlled to affect output pulse characteristics. The laser acts a master oscillator in a master oscillator power amplifier configuration. The laser is used for laser peening.

  12. Self-seeded single-frequency laser peening method

    DOEpatents

    Dane, C Brent [Livermore, CA; Hackel, Lloyd [Livermore, CA; Harris, Fritz B [Rocklin, CA

    2009-08-11

    A method of operating a laser to obtain an output pulse having a single wavelength, comprises inducing an intracavity loss into a laser resonator having an amount that prevents oscillation during a time that energy from the pump source is being stored in the gain medium. Gain is built up in the gain medium with energy from the pump source until formation of a single-frequency relaxation oscillation pulse in the resonator. Upon detection of the onset of the relaxation oscillation pulse, the intracavity loss is reduced, such as by Q-switching, so that the built-up gain stored in the gain medium is output from the resonator in the form of an output pulse at a single frequency. An electronically controllable output coupler is controlled to affect output pulse characteristics. The laser acts a master oscillator in a master oscillator power amplifier configuration. The laser is used for laser peening.

  13. Self-seeded single-frequency laser peening method

    DOEpatents

    DAne, C Brent; Hackey, Lloyd A; Harris, Fritz B

    2012-06-26

    A method of operating a laser to obtain an output pulse having a single wavelength, comprises inducing an intracavity loss into a laser resonator having an amount that prevents oscillation during a time that energy from the pump source is being stored in the gain medium. Gain is built up in the gain medium with energy from the pump source until formation of a single-frequency relaxation oscillation pulse in the resonator. Upon detection of the onset of the relaxation oscillation pulse, the intracavity loss is reduced, such as by Q-switching, so that the built-up gain stored in the gain medium is output from the resonator in the form of an output pulse at a single frequency. An electronically controllable output coupler is controlled to affect output pulse characteristics. The laser acts a master oscillator in a master oscillator power amplifier configuration. The laser is used for laser peening.

  14. Association of neonatal necrotizing enterocolitis with myeloid differentiation-2 and GM2 activator protein genetic polymorphisms.

    PubMed

    Zhou, Wei; Yuan, Weiming; Huang, Longguang; Wang, Ping; Rong, Xiao; Tang, Juan

    2015-07-01

    The aim of the present study was to investigate the association of neonatal necrotizing enterocolitis (NEC) with myeloid differentiation-(MD-2) and GM2 activator protein (GM2A) genetic polymorphisms. Gene resequencing of the MD-2 and GM2A gene exons was performed on 42 neonates, diagnosed with NEC (NEC group), as well as in the rs11465996 locus, located in the MD-2 gene promoter region. The aim was to detect the genetic polymorphisms present in the neonates with NEC and compare the functional polymorphic loci with 83 neonates without NEC (control group), who had been born during the same period. A polymorphic locus with abnormal frequency was detected in the exon region of the MD-2 gene. In the NEC group, the frequency of genotypes carrying the low frequency allele (G) in the rs11465996 locus (MD-2 promoter region) was significantly higher compared with the control group (χ(2)=4.388, P=0.036). Furthermore, the frequencies of genotypes carrying the low frequency A and C alleles in the rs1048719 (GM2A gene exon 1) and rs2075783 loci (GM2A intron), respectively, were significantly higher in the NEC group compared with the control group (χ(2)=4.316, P=0.038; and χ(2)=13.717, P=0.000, respectively). In addition, the rs11465996 polymorphism in the MD-2 gene promoter region was found to be associated with the severity of NEC. Furthermore, the rs2075783 polymorphism in the GM2A gene exon 1 and the rs1048719 polymorphism in the intron region of this gene, were associated with the occurrence of NEC. The present study demonstrated that gene polymorphisms of MD-2 and GM2A were associated with the occurrence or severity of NEC; however, further in-depth exploration is required to clarify the associations between genetic predispositions to polymorphisms, and NEC.

  15. Tuning time-frequency methods for the detection of metered HF speech

    NASA Astrophysics Data System (ADS)

    Nelson, Douglas J.; Smith, Lawrence H.

    2002-12-01

    Speech is metered if the stresses occur at a nearly regular rate. Metered speech is common in poetry, and it can occur naturally in speech, if the speaker is spelling a word or reciting words or numbers from a list. In radio communications, the CQ request, call sign and other codes are frequently metered. In tactical communications and air traffic control, location, heading and identification codes may be metered. Moreover metering may be expected to survive even in HF communications, which are corrupted by noise, interference and mistuning. For this environment, speech recognition and conventional machine-based methods are not effective. We describe Time-Frequency methods which have been adapted successfully to the problem of mitigation of HF signal conditions and detection of metered speech. These methods are based on modeled time and frequency correlation properties of nearly harmonic functions. We derive these properties and demonstrate a performance gain over conventional correlation and spectral methods. Finally, in addressing the problem of HF single sideband (SSB) communications, the problems of carrier mistuning, interfering signals, such as manual Morse, and fast automatic gain control (AGC) must be addressed. We demonstrate simple methods which may be used to blindly mitigate mistuning and narrowband interference, and effectively invert the fast automatic gain function.

  16. Cardiovagal Autonomic Function in HIV-Infected Patients with Unsuppressed HIV Viremia

    PubMed Central

    Chow, Dominic C.; Wood, Robert; Choi, Julia; Grandinetti, Andrew; Gerschenson, Mariana; Sriratanaviriyakul, Narin; Nakamoto, Beau; Shikuma, Cecilia; Low, Phillip

    2011-01-01

    Purpose HIV infection has been implicated in dysregulation of the autonomic nervous system. Method Cross-sectional study examining the relationship between the presence of persistent detectable HIV viral load with autonomic function, measured by heart rate variability (HRV). Non-virologic suppression (NVS) was defined as having a detectable viral load for at least 3 months prior to autonomic function testing. HRV was measured during the following 4 maneuvers: resting and paced respirations and sustained handgrip and tilt. Inferences on parasympathetic and sympathetic modulations were determined by analyzing time and frequency domains of HRV. Results 57 participants were enrolled in 3 groups: 22 were HIV-infected participants with HIV virologic suppression (VS; undetectable HIV viral load), 9 were HIV-infected participants who had NVS, and 26 were HIV seronegative controls. There were lower time domain parameters in the HIV-infected group as a whole compared to controls. There were no significant differences in time domain parameters among HIV-infected participants. There were no differences in frequency domain parameters during any of the maneuvers between controls and all HIV-infected participants, nor between the NVS and VS groups. Conclusion There were differences in autonomic function between HIV-infected individuals and HIV seronegative controls, but not between the NVS and VS groups. PMID:21684854

  17. Cervical neoplasia and human papilloma virus infection in prostitutes.

    PubMed

    Gitsch, G; Kainz, C; Reinthaller, A; Kopp, W; Tatra, G; Breitenecker, G

    1991-12-01

    To evaluate the prevalence and incidence of PAP smears indicating cervical dysplasia as well as human papillomavirus (HPV) infection in prostitutes. Prevalence and incidence study of cervical dysplasia and HPV infection in prostitutes. For detection and typing of HPV-DNA In Situ Hybridisation (ISH) was performed in tissue samples with CIN gained by colposcopically directed punch biopsies. Second Department of Obstetrics and Gynecology, University of Vienna Medical School and STD Clinic of the Public Health Office, Vienna. Registered prostitutes attending the STD Clinic of the Public Health Office and a control group. 978 prostitutes and 5493 women with unknown cytological anamnesis were compared. Frequency of positive PAP smears was significantly higher in prostitutes (6.13% versus 1.43%). To determine the pick-up rate of cervical dysplasia during one year after negative cytology we compared 722 prostitutes and 3162 controls. Prostitutes showed a significant higher dysplasia pick-up rate (3.05% to 1.07%) compared with controls. HPV detection rate in prostitutes was similar to that in the control group. The distribution of HPV types revealed a higher frequency of "high risk" HPV 16/18 and 31/33 in prostitutes. The results demonstrate a higher incidence and prevalence of cervical dysplasia in prostitutes and therefore suggest regular cervical PAP smear screening in registered prostitutes twice a year.

  18. No association of the neuropeptide Y (Leu7Pro) and ghrelin gene (Arg51Gln, Leu72Met, Gln90Leu) single nucleotide polymorphisms with eating disorders.

    PubMed

    Kindler, Jochen; Bailer, Ursula; de Zwaan, Martina; Fuchs, Karoline; Leisch, Friedrich; Grün, Bettina; Strnad, Alexandra; Stojanovic, Mirjana; Windisch, Julia; Lennkh-Wolfsberg, Claudia; El-Giamal, Nadja; Sieghart, Werner; Kasper, Siegfried; Aschauer, Harald

    2011-06-01

    Genetic factors likely contribute to the biological vulnerability of eating disorders. Case-control association study on one neuropeptide Y gene (Leu7Pro) polymorphism and three ghrelin gene (Arg51Gln, Leu72Met and Gln90Leu) polymorphisms. 114 eating disorder patients (46 with anorexia nervosa, 30 with bulimia nervosa, 38 with binge eating disorder) and 164 healthy controls were genotyped. No differences were detected between patients and controls for any of the four polymorphisms in allele frequency and genotype distribution (P > 0.05). Allele frequencies and genotypes had no significant influence on body mass index (P > 0.05) in eating disorder patients. Positive findings of former case-control studies of associations between ghrelin gene polymorphisms and eating disorders could not be replicated. Neuropeptide Y gene polymorphisms have not been investigated in eating disorders before.

  19. Microwave Kinetic Inductance Detector with Selective Polarization Coupling

    NASA Technical Reports Server (NTRS)

    Wollack, Edward; U-yen, Kongpop; Stevenson, Thomas; Brown, Ari; Moseley, Samuel; Hsieh, Wen-Ting

    2013-01-01

    A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

  20. Emergent HIV-1 Drug Resistance Mutations Were Not Present at Low-Frequency at Baseline in Non-Nucleoside Reverse Transcriptase Inhibitor-Treated Subjects in the STaR Study

    PubMed Central

    Porter, Danielle P.; Daeumer, Martin; Thielen, Alexander; Chang, Silvia; Martin, Ross; Cohen, Cal; Miller, Michael D.; White, Kirsten L.

    2015-01-01

    At Week 96 of the Single-Tablet Regimen (STaR) study, more treatment-naïve subjects that received rilpivirine/emtricitabine/tenofovir DF (RPV/FTC/TDF) developed resistance mutations compared to those treated with efavirenz (EFV)/FTC/TDF by population sequencing. Furthermore, more RPV/FTC/TDF-treated subjects with baseline HIV-1 RNA >100,000 copies/mL developed resistance compared to subjects with baseline HIV-1 RNA ≤100,000 copies/mL. Here, deep sequencing was utilized to assess the presence of pre-existing low-frequency variants in subjects with and without resistance development in the STaR study. Deep sequencing (Illumina MiSeq) was performed on baseline and virologic failure samples for all subjects analyzed for resistance by population sequencing during the clinical study (n = 33), as well as baseline samples from control subjects with virologic response (n = 118). Primary NRTI or NNRTI drug resistance mutations present at low frequency (≥2% to 20%) were detected in 6.6% of baseline samples by deep sequencing, all of which occurred in control subjects. Deep sequencing results were generally consistent with population sequencing but detected additional primary NNRTI and NRTI resistance mutations at virologic failure in seven samples. HIV-1 drug resistance mutations emerging while on RPV/FTC/TDF or EFV/FTC/TDF treatment were not present at low frequency at baseline in the STaR study. PMID:26690199

  1. Emergent HIV-1 Drug Resistance Mutations Were Not Present at Low-Frequency at Baseline in Non-Nucleoside Reverse Transcriptase Inhibitor-Treated Subjects in the STaR Study.

    PubMed

    Porter, Danielle P; Daeumer, Martin; Thielen, Alexander; Chang, Silvia; Martin, Ross; Cohen, Cal; Miller, Michael D; White, Kirsten L

    2015-12-07

    At Week 96 of the Single-Tablet Regimen (STaR) study, more treatment-naïve subjects that received rilpivirine/emtricitabine/tenofovir DF (RPV/FTC/TDF) developed resistance mutations compared to those treated with efavirenz (EFV)/FTC/TDF by population sequencing. Furthermore, more RPV/FTC/TDF-treated subjects with baseline HIV-1 RNA >100,000 copies/mL developed resistance compared to subjects with baseline HIV-1 RNA ≤100,000 copies/mL. Here, deep sequencing was utilized to assess the presence of pre-existing low-frequency variants in subjects with and without resistance development in the STaR study. Deep sequencing (Illumina MiSeq) was performed on baseline and virologic failure samples for all subjects analyzed for resistance by population sequencing during the clinical study (n = 33), as well as baseline samples from control subjects with virologic response (n = 118). Primary NRTI or NNRTI drug resistance mutations present at low frequency (≥2% to 20%) were detected in 6.6% of baseline samples by deep sequencing, all of which occurred in control subjects. Deep sequencing results were generally consistent with population sequencing but detected additional primary NNRTI and NRTI resistance mutations at virologic failure in seven samples. HIV-1 drug resistance mutations emerging while on RPV/FTC/TDF or EFV/FTC/TDF treatment were not present at low frequency at baseline in the STaR study.

  2. Interference Information Based Power Control for Cognitive Radio with Multi-Hop Cooperative Sensing

    NASA Astrophysics Data System (ADS)

    Yu, Youngjin; Murata, Hidekazu; Yamamoto, Koji; Yoshida, Susumu

    Reliable detection of other radio systems is crucial for systems that share the same frequency band. In wireless communication channels, there is uncertainty in the received signal level due to multipath fading and shadowing. Cooperative sensing techniques in which radio stations share their sensing information can improve the detection probability of other systems. In this paper, a new cooperative sensing scheme that reduces the false detection probability while maintaining the outage probability of other systems is investigated. In the proposed system, sensing information is collected using multi-hop transmission from all sensing stations that detect other systems, and transmission decisions are based on the received sensing information. The proposed system also controls the transmit power based on the received CINRs from the sensing stations. Simulation results reveal that the proposed system can reduce the outage probability of other systems, or improve its link success probability.

  3. Cytogenetic Biomonitoring in Buccal Mucosal Cells from Municipal Solid Waste Collectors.

    PubMed

    Andrade, Mariana Carvalho; Dos Santos, Jean Nunes; Cury, Patricia Ramos; Flygare, Ana Carolina Correa; Claudio, Samuel Rangel; Oshima, Celina Tizuko Fujiyama; Ribeiro, Daniel Araki

    2017-02-01

    Waste collectors collect, transport, and process the garbage produced by people living in the city. Nowadays, this activity requires special attention due to the environmental impact of garbage and its potential consequences on human health. The aim of this study was to evaluate potential cytotoxic and mutagenic effects of garbage collection on waste collectors. For this purpose, a total of 47 male waste collectors aged from 24 to 53 years were included in the experimental group. A total of 30 men matched by age were used as the control group. Cytotoxicity and mutagenicity were analyzed by micronucleus test in buccal mucosaI cells. No statistically significant difference (p>0.05) in the frequency of micronuclei was detected in the waste collectors when compared to controls. Nevertheless, higher frequencies of karyolysis and pyknosis (p<0.05) were detected in buccal mucosaI cells from waste collectors when compared to matched controls. Taken together, our results indicate that waste collectors comprise an at-risk group as a result of increased cytotoxicity apparent from buccal mucosa cells. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  4. Polymorphisms of glutathione S-transferase π 1 and toll-like receptors 2 and 9: Association with breast cancer susceptibility

    PubMed Central

    AL-HARRAS, MOHAMMAD F.; HOUSSEN, MAHA E.; SHAKER, MOHAMED E.; FARAG, KAMEL; FAROUK, OMAR; MONIR, REHAN; EL-MAHDY, RASHA; ABO-HASHEM, EKBAL M.

    2016-01-01

    Polymorphisms in antioxidant enzymes and innate immune receptors have been implicated in the development of various types of cancer. The present study aimed to investigate whether polymorphisms of glutathione S-transferase π 1 (GSTP1) and toll-like receptors (TLRs) 2 and 9 are associated with susceptibility to breast cancer among females. The study was conducted on 72 Egyptian female patients with breast cancer, along with 100 healthy volunteers. Polymorphisms of GSTP1 (codon 105 Ile/Val) and TLR9 rs187084 (1237T/C) genes were assessed by polymerase chain reaction (PCR)-restriction fragment length polymorphism, while the −196 to −174 deletion/insertion (del/ins) polymorphism of TLR2 was detected by PCR. The results indicated a decrease in GSTP1 Val allele frequency in breast cancer patients compared with healthy controls, at rates of 22.9 vs. 32.5%, respectively. In addition, the breast cancer group demonstrated a decreased TLR9 C allele frequency compared with the control group, at rates of 36.1 vs. 51.5%, respectively (P=0.0047). A non-significant difference was detected in the frequency of the TLR2 −196 to −174 del allele in breast cancer patients when compared to normal controls. In conclusion, these results suggested that the GSTP1 Val and TLR9 1237C alleles, but not TLR2 −196 to −174 del, are likely to be associated with breast cancer development among females. PMID:26998146

  5. Polymorphisms of glutathione S-transferase π 1 and toll-like receptors 2 and 9: Association with breast cancer susceptibility.

    PubMed

    Al-Harras, Mohammad F; Houssen, Maha E; Shaker, Mohamed E; Farag, Kamel; Farouk, Omar; Monir, Rehan; El-Mahdy, Rasha; Abo-Hashem, Ekbal M

    2016-03-01

    Polymorphisms in antioxidant enzymes and innate immune receptors have been implicated in the development of various types of cancer. The present study aimed to investigate whether polymorphisms of glutathione S-transferase π 1 (GSTP1) and toll-like receptors (TLRs) 2 and 9 are associated with susceptibility to breast cancer among females. The study was conducted on 72 Egyptian female patients with breast cancer, along with 100 healthy volunteers. Polymorphisms of GSTP1 (codon 105 Ile/Val) and TLR9 rs187084 (1237T/C) genes were assessed by polymerase chain reaction (PCR)-restriction fragment length polymorphism, while the -196 to -174 deletion/insertion (del/ins) polymorphism of TLR2 was detected by PCR. The results indicated a decrease in GSTP1 Val allele frequency in breast cancer patients compared with healthy controls, at rates of 22.9 vs. 32.5%, respectively. In addition, the breast cancer group demonstrated a decreased TLR9 C allele frequency compared with the control group, at rates of 36.1 vs. 51.5%, respectively (P=0.0047). A non-significant difference was detected in the frequency of the TLR2 -196 to -174 del allele in breast cancer patients when compared to normal controls. In conclusion, these results suggested that the GSTP1 Val and TLR9 1237C alleles, but not TLR2 -196 to -174 del, are likely to be associated with breast cancer development among females.

  6. [Acoustic detection of absorption of millimeter-band electromagnetic waves in biological objects].

    PubMed

    Polnikov, I G; Putvinskiĭ, A V

    1988-01-01

    Principles of photoacoustic spectroscopy were applied to elaborate a new method for controlling millimeter electromagnetic waves absorption in biological objects. The method was used in investigations of frequency dependence of millimeter wave power absorption in vitro and in vivo in the commonly used experimental irradiation systems.

  7. Middle infrared optoelectronic absorption systems for monitoring physiological glucose solutions

    NASA Astrophysics Data System (ADS)

    Martin, W. Blake

    Tight monitoring of the glucose levels for diabetic individuals is essential to control long-term complications. A definitive diabetes management system has yet to be developed for the diabetic. This research investigates the application of middle infrared absorption frequencies for monitoring glucose levels in biological solutions. Three frequencies were identified using a Fourier transform infrared spectrometer and correlated to changes in glucose concentrations. The 1035 +/- 1 cm-1 frequency was determined to be the best representative frequency. Other biological molecules contributed no significant interference to monitoring glucose absorption. A second frequency at 1193 cm-1 was suggested as a representative background absorption frequency, which could be used for more accurate glucose absorption values. Next, a quantum cascade laser optoelectronic absorption system was designed and developed to monitor glucose. After careful alignment and design, the system was used to monitor physiological glucose concentrations. Correlation at 1036 cm-1 with glucose changes was comparable to the previous results. The use of the background absorption frequency was verified. This frequency essentially acts as a calibrating frequency to adjust in real-time to any changes in the background absorption that may alter the accuracy of the predicted glucose value. An evanescent wave cavity ring-down spectroscopy technique was explored to monitor molecules in a biological solution. Visible light at 425 nm was used to monitor hemoglobin in control urine samples. An adsorption isotherm for hemoglobin was detectable to limit of 5.8 nM. Evanescent wave cavity ring-down spectroscopy would be useful for a glucose solution. Given an equivalent system designed for the middle infrared, the molar extinction coefficient of glucose allows for a detectable limit of 45 mg/dl for a free-floating glucose solution, which is below normal physiological concentrations. The future use of a hydrophobic coating could limit the adsorption of glucose to the surface but still allow physiological monitoring. Three middle infrared optoelectronic absorption systems have been designed for monitoring glucose in a physiological solution. The systems are applicable for the monitoring of glucose. These systems may lead to a useful monitoring device for the diabetic so that the universal complications associated with the disease may be limited.

  8. Detection of small metal particles by a quasi-optical system at sub-millimeter wavelength

    NASA Astrophysics Data System (ADS)

    Kitahara, Yasuyuki; Domier, C. W.; Ikeda, Makoto; Pham, Anh-Vu; Luhmann, Neville C.

    2016-04-01

    Inspection of alien metal particles in electronic materials such as glass fibers and resins is a critical issue to control the quality and guarantee the safety of products. In this paper, we present a new detection technique using sub-millimeter wave for films as electric materials in product lines. The advantage of using sub-millimeter wave frequency is that it is easy to distinguish conductive particles from a nonconductive material such as plastic films. Scattering of a submillimeter wave by a metal particle is used as the detection principle. By simulation, it is observed that the scattering pattern varies intricately as the diameter varies from 10 to 700 μm at 300 GHz. The demonstration system is composed of a Keysight performance network analyzer (N5247A PNA-X) with 150-330 GHz VDI extension modules, transmitting and receiving antennas, and focusing dielectric lens. An output signal is radiated via an antenna and focused onto a metal particle on a film. The wave scattered by the metal particle is detected by an identical antenna through a lens. The signal scattered from a metal particle is evaluated from the insertion loss between antennas (S21). The result shows that a particle of diameter 300 μm is detectable at 150-330 GHz through S21 in the experimental system that we prepared. Peaks calculated in simulation were detected in experimental data as well as in the curves of the particle diameter versus S21. It was shown that using this peak frequency could improve S21 level without higher frequency.

  9. Precise fiber length measurement using harmonic detection of phase-locked cavity modes

    NASA Astrophysics Data System (ADS)

    Terra, Osama

    2018-06-01

    In this paper, precise length measurements of optical fibers are performed by employing harmonic detection of the pulse-train frequency of a passively mode-locked fiber laser. This frequency is proportional to the length of the laser cavity in which the measured fiber is installed. Our proposed technique enables length measurement of long fibers from 1 to 40 km with precision from 0.4 to 8 mm and short fibers of few meters with precision as low as 26 μm. Such superior precision is achieved not only by the selection of higher harmonics of up to 1410, but also by the careful control of the wavelength at which the passive mode-locking occur, because of the broadband nature of the used gain medium.

  10. Stable Short-Term Frequency Support Using Adaptive Gains for a DFIG-Based Wind Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jinsik; Jang, Gilsoo; Muljadi, Eduard

    For the fixed-gain inertial control of wind power plants (WPPs), a large gain setting provides a large contribution to supporting system frequency control, but it may cause over-deceleration for a wind turbine generator that has a small amount of kinetic energy (KE). Further, if the wind speed decreases during inertial control, even a small gain may cause over-deceleration. This paper proposes a stable inertial control scheme using adaptive gains for a doubly fed induction generator (DFIG)-based WPP. The scheme aims to improve the frequency nadir (FN) while ensuring stable operation of all DFIGs, particularly when the wind speed decreases duringmore » inertial control. In this scheme, adaptive gains are set to be proportional to the KE stored in DFIGs, which is spatially and temporally dependent. To improve the FN, upon detecting an event, large gains are set to be proportional to the KE of DFIGs; to ensure stable operation, the gains decrease with the declining KE. The simulation results demonstrate that the scheme improves the FN while ensuring stable operation of all DFIGs in various wind and system conditions. Further, it prevents over-deceleration even when the wind speed decreases during inertial control.« less

  11. Tumour necrosis factor (TNF)-α-308 gene polymorphism in Indian patients with Takayasu's arteritis - a pilot study.

    PubMed

    Sandhya, P; Danda, Sumita; Danda, Debashish; Lonarkar, Shraddha; Luke, Shana S; Sinha, Shanta; Joseph, George

    2013-04-01

    Tumour necrosis factor-alpha (TNF-α)- 308 promoter gene polymorphism has been shown to be associated with several autoimmune disorders and infections such as tuberculosis. There is no study on TNF-α gene polymorphism in Takayasu's arteritis (TA) till date. We aimed to study this polymorphism in TA, a granulomatous vasculitis, probably triggered by Mycobacterium tuberculosis. TNF-α - 308 gene polymorphism was studied in 34 patients with TA and 39 healthy controls recruited from Christian Medical College, India. PCR was done followed by enzyme digestion. G and A polymorphisms were analysed. Occurrence of alleles in the disease group was compared with controls as well as with historical controls. GG allele was most frequent in TA and in controls. GA allele was detected in four controls but only in one patient who was the oldest in the study group. AA polymorphism was detected in one control but not in TA. When compared with controls from other populations, it was found that our allelic frequency was similar to that in Japan as well as from USA with mixed population. However, predominantly Caucasian population studied from Netherlands, Germany and England, where TA is rare, had a higher frequency of A allele as compared to our controls. Our preliminary results indicated that G allele at TNF-α - 308 was more common in TA patients and controls similar to that in other Indian as well as Japanese population. Compared to the western population, A allele was relatively less common in our study subjects.

  12. Dangerous animals capture and maintain attention in humans.

    PubMed

    Yorzinski, Jessica L; Penkunas, Michael J; Platt, Michael L; Coss, Richard G

    2014-05-28

    Predation is a major source of natural selection on primates and may have shaped attentional processes that allow primates to rapidly detect dangerous animals. Because ancestral humans were subjected to predation, a process that continues at very low frequencies, we examined the visual processes by which men and women detect dangerous animals (snakes and lions). We recorded the eye movements of participants as they detected images of a dangerous animal (target) among arrays of nondangerous animals (distractors) as well as detected images of a nondangerous animal (target) among arrays of dangerous animals (distractors). We found that participants were quicker to locate targets when the targets were dangerous animals compared with nondangerous animals, even when spatial frequency and luminance were controlled. The participants were slower to locate nondangerous targets because they spent more time looking at dangerous distractors, a process known as delayed disengagement, and looked at a larger number of dangerous distractors. These results indicate that dangerous animals capture and maintain attention in humans, suggesting that historical predation has shaped some facets of visual orienting and its underlying neural architecture in modern humans.

  13. Objective measurement of subjective tinnitus using the acoustic change complex.

    PubMed

    Han, Ji-Hye; Won, Joong Yeon; Hong, Sung Kwang; Kim, Ja Hee; Kim, Eun Soo; Kim, Hyung-Jong; Lee, Hyo-Jeong

    2017-01-01

    At present, there is no objective method for diagnosing subjective sensorineural tinnitus. Recently, the acoustic change complex (ACC) has been used to evaluate neural detection of sounds. Thus, the present study aimed to examine whether the ACC can reflect cortical detection and discrimination of sounds matched with tinnitus frequencies. We hypothesized that the ACC to change stimuli matched with tinnitus frequencies would be decreased in tinnitus patients because the tinnitus interferes with the perception of acoustic changes. To test the hypothesis, 96 ears of normal-hearing (NH) tinnitus patients and controls were tested. Among the tinnitus patients, 33 ears with a tinnitus frequency of 8 kHz constituted the tinnitus group, and the remaining 63 ears with no experience of tinnitus were allocated to the control group. For the 4 kHz non-tinnitus matched frequency, a subset of tinnitus (n = 17) and NH (n = 47) subjects was tested. The acoustic stimuli were pure tones with a total duration of 500 ms consisting of a 1 kHz tone in the first 250 ms and a second tone of either 8 kHz or 4 kHz in the latter 250 ms. The normalized amplitude of the ACC (naACC) was calculated separately for the amplitude of the N1'-P2' complex evoked by an 8 kHz or 4 kHz change stimulus and for the amplitude of the N1-P2 complex elicited by the initial 1 kHz background stimulus. Our results showed that the naACC to an 8 kHz stimulus in the tinnitus group was significantly smaller than those to 4 kHz and 8 kHz in normal controls. Additionally, in the tinnitus group, the naACC to 4 kHz was greater compared to 8 kHz. The receiver operating characteristic (ROC) curve analysis conducted for naACC to 8 kHz at UCL revealed a fair degree of diagnostic efficacy. Overall, our results indicated that the ACC to a change stimulus matched with the tinnitus frequency can provide an objective measure of frequency-specific tinnitus.

  14. Objective measurement of subjective tinnitus using the acoustic change complex

    PubMed Central

    Han, Ji-Hye; Won, Joong Yeon; Hong, Sung Kwang; Kim, Ja Hee; Kim, Eun Soo; Kim, Hyung-Jong

    2017-01-01

    At present, there is no objective method for diagnosing subjective sensorineural tinnitus. Recently, the acoustic change complex (ACC) has been used to evaluate neural detection of sounds. Thus, the present study aimed to examine whether the ACC can reflect cortical detection and discrimination of sounds matched with tinnitus frequencies. We hypothesized that the ACC to change stimuli matched with tinnitus frequencies would be decreased in tinnitus patients because the tinnitus interferes with the perception of acoustic changes. To test the hypothesis, 96 ears of normal-hearing (NH) tinnitus patients and controls were tested. Among the tinnitus patients, 33 ears with a tinnitus frequency of 8 kHz constituted the tinnitus group, and the remaining 63 ears with no experience of tinnitus were allocated to the control group. For the 4 kHz non-tinnitus matched frequency, a subset of tinnitus (n = 17) and NH (n = 47) subjects was tested. The acoustic stimuli were pure tones with a total duration of 500 ms consisting of a 1 kHz tone in the first 250 ms and a second tone of either 8 kHz or 4 kHz in the latter 250 ms. The normalized amplitude of the ACC (naACC) was calculated separately for the amplitude of the N1’-P2’ complex evoked by an 8 kHz or 4 kHz change stimulus and for the amplitude of the N1-P2 complex elicited by the initial 1 kHz background stimulus. Our results showed that the naACC to an 8 kHz stimulus in the tinnitus group was significantly smaller than those to 4 kHz and 8 kHz in normal controls. Additionally, in the tinnitus group, the naACC to 4 kHz was greater compared to 8 kHz. The receiver operating characteristic (ROC) curve analysis conducted for naACC to 8 kHz at UCL revealed a fair degree of diagnostic efficacy. Overall, our results indicated that the ACC to a change stimulus matched with the tinnitus frequency can provide an objective measure of frequency-specific tinnitus. PMID:29176873

  15. Malformations detected by abdominal ultrasound in children with congenital heart disease.

    PubMed

    Rosa, Rosana Cardoso Manique; Rosa, Rafael Fabiano Machado; Flores, José Antônio Monteiro; Golendziner, Eliete; Oliveira, Ceres Andréia Vieira de; Varella-Garcia, Marileila; Paskulin, Giorgio Adriano; Zen, Paulo Ricardo Gazzola

    2012-12-01

    Extracardiac malformations may be present in patients with congenital heart disease (CHD), bringing greater risk of comorbidity and mortality. Verify frequency and types of abdominal abnormalities detected in children with and without CHD through abdominal ultrasound (AUS), compare the patients in relation to their dysmorphic/cytogenetic findings and perform an estimative of the cost-effectiveness of the screening through AUS. We conducted a cross-sectional study with a control cohort. The cases consisted of patients with CHD admitted for the first time in a pediatric intensive care unit; the controls consisted of children without CHD who underwent AUS at the hospital shortly thereafter a case. All patients with CHD underwent AUS, high-resolution karyotype and fluorescence in situ hybridization (FISH) for microdeletion 22q11.2. AUS identified clinically significant abnormalities in 12.2% of the cases and 5.2% of controls (p= 0.009), with a power of significance of 76.6%. Most malformations with clinical significance were renal anomalies (10.4% in cases and 4.9% in controls; p= 0.034). In Brazil, the cost of an AUS examination for the Unified Health System is US$ 21. Since clinically significant abnormalities were observed in one in every 8.2 CHD patients, the cost to identify an affected child was calculated as approximately US$ 176. Patients with CHD present a significant frequency of abdominal abnormalities detected by AUS, an inexpensive and noninvasive diagnostic method with good sensitivity. The cost of screening for these defects is considerably lower than the cost to treat the complications of late diagnoses of abdominal malformations such as renal disease.

  16. Proposal and verification numerical simulation for a microwave forward scattering technique at upper hybrid resonance for the measurement of electron gyroscale density fluctuations in the electron cyclotron frequency range in magnetized plasmas

    NASA Astrophysics Data System (ADS)

    Kawamori, E.; Igami, H.

    2017-11-01

    A diagnostic technique for detecting the wave numbers of electron density fluctuations at electron gyro-scales in an electron cyclotron frequency range is proposed, and the validity of the idea is checked by means of a particle-in-cell (PIC) numerical simulation. The technique is a modified version of the scattering technique invented by Novik et al. [Plasma Phys. Controlled Fusion 36, 357-381 (1994)] and Gusakov et al., [Plasma Phys. Controlled Fusion 41, 899-912 (1999)]. The novel method adopts forward scattering of injected extraordinary probe waves at the upper hybrid resonance layer instead of the backward-scattering adopted by the original method, enabling the measurement of the wave-numbers of the fine scale density fluctuations in the electron-cyclotron frequency band by means of phase measurement of the scattered waves. The verification numerical simulation with the PIC method shows that the technique has a potential to be applicable to the detection of electron gyro-scale fluctuations in laboratory plasmas if the upper-hybrid resonance layer is accessible to the probe wave. The technique is a suitable means to detect electron Bernstein waves excited via linear mode conversion from electromagnetic waves in torus plasma experiments. Through the numerical simulations, some problems that remain to be resolved are revealed, which include the influence of nonlinear processes such as the parametric decay instability of the probe wave in the scattering process, and so on.

  17. One-shot and aberration-tolerable homodyne detection for holographic storage readout through double-frequency grating-based lateral shearing interferometry.

    PubMed

    Yu, Yeh-Wei; Xiao, Shuai; Cheng, Chih-Yuan; Sun, Ching-Cherng

    2016-05-16

    A simple method to decode the stored phase signal of volume holographic data storage with adequate wave aberration tolerance is highly demanded. We proposed and demonstrated a one-shot scheme to decode a binary-phase encoding signal through double-frequency-grating based shearing interferometry (DFGSI). The lateral shearing amount is dependent on the focal length of the collimated lens and the frequency difference between the gratings. Diffracted waves with phase encoding were successfully decoded through experimentation. An optical model for the DFGSI was built to analyze phase-error induction and phase-difference control by shifting the double-frequency grating longitudinally and laterally, respectively. The optical model was demonstrated experimentally. Finally, a high aberration tolerance of the DFGSI was demonstrated using the optical model.

  18. Benzimidazole resistance in equine cyathostomins in India.

    PubMed

    Kumar, Sunil; Garg, Rajat; Kumar, Saroj; Banerjee, P S; Ram, Hira; Prasad, A

    2016-03-15

    Benzimidazole resistance is a major hindrance to the control of equine cyathostominosis throughout the world. There is a paucity of knowledge on the level of benzimidazole resistance in small strongyles of horses in India. In the present study, allele-specific PCR (AS-PCR) that detects F200Y mutation of the isotype 1 β-tubulin gene and faecal egg count reduction test (FECRT) were used for detecting benzimidazole resistance in equine cyathostomin populations in different agro-climatic zones of Uttar Pradesh, India. Results of the FECRT revealed prevalence of benzimidazole resistance in cyathostomins in an intensively managed equine farm in the mid-western plain (FECR=27.5%, LCI=0) and in working horses (extensively managed) at three locations in central plains of Uttar Pradesh (FECR=75.7-83.6%, LCI=29-57%). Post-treatment larval cultures revealed the presence of exclusively cyathostomin larvae. Genotyping of cyathostomin larvae by AS-PCR revealed that the frequency of homozygous resistant (rr) individuals and the resistant allele frequency was significantly higher (p<0.001) in the intensively managed farm in the mid-western plain and in working horses at two locations in central plains of the state. The resistant allele (r) frequency in cyathostomins was significantly higher (p<0.05) in Vindhyan and Tarai and Bhabar zones of Uttar Pradesh. The prevalence of benzimidazole resistant allele (r) was significantly higher (p<0.05) in cyathostomins of intensively managed horses (allelic frequency-0.35) as compared to extensively managed horses (allelic frequency-0.22). The widespread prevalence of benzimidazole resistant alleles in equine cyathostomins in Uttar Pradesh, India, necessitates immediate replacement of the drugs of benzimidazole group with other unrelated effective anthelmintics for management and control of equine cyathostomins. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. High prevalence of dengue antibodies and the arginine variant of the FcγRIIa polymorphism in asymptomatic individuals in a population of Minas Gerais State, Southeast Brazil.

    PubMed

    Pereira, Anna Carolina Toledo da Cunha; de Siqueira, Tatiane Ribeiro; de Oliveira Prado, Andressa Anunciação; da Silva, Camila Almeida Veiga; de Fátima Silva Moraes, Thaís; Aleixo, Alan Alex; de Magalhaes, José Carlos; de Souza, Gabriel Augusto Pires; Drumond, Betânia Paiva; Ferreira, Gustavo Portela; de Mello Silva, Breno; de Brito Magalhães, Cintia Lopes; Santos, Luciana Lara; Ferreira, Jaqueline Maria Siqueira; Malaquias, Luiz Cosme Cotta; Coelho, Luiz Felipe Leomil

    2018-06-01

    Dengue is the most prevalent arthropod-borne viral illness in humans worldwide. Single-nucleotide polymorphisms (SNPs) in genes involved in the immune response, such as dendritic cell-specific intercellular adhesion molecule-3-grabbing non-integrin (DC-SIGN), IgG Fc receptor II-A (FcγRIIa), vitamin D receptor (VDR), and tumor necrosis factor alpha (TNF-α), were previously reported to be associated with susceptibility to dengue disease in different human populations. Therefore, due to the relevant association of host immune and genetic status with disease susceptibility/severity of dengue, this work aims to verify the frequency of anti-dengue virus antibodies and some dengue-associated risk SNPs in a population in Minas Gerais State, Southeast Brazil. A total of 1560 individuals were genotyped for polymorphisms in DC-SIGN (rs4804803), FcγRIIa (rs1801274), VDR (rs7975232), and TNF-α (rs1800629). The presence of anti-dengue antibodies (IgM and/or IgG) in these samples was also assayed. Anti-dengue antibodies were detected at an overall frequency of 16.86%, indicating a virus infection in asymptomatic individuals. The genotypic frequencies of all SNPs studied did not differ between the asymptomatic and control groups. Regarding the allelic frequencies of the four SNPs analyzed, a higher frequency was detected of the G allele of FcγRIIa/rs1801274 in the asymptomatic individuals when compared to that in the control group (p = 0.03). Therefore, the results showed a high prevalence of asymptomatic individuals in Minas Gerais State, with a potential association between the presence of the G allele of FcγRIIa/rs1801274 and protection against symptomatic disease.

  20. On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sappok, Alex; Ragaller, Paul; Herman, Andrew

    The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directlymore » monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.« less

  1. Research on Integrated Control of Microgrid Operation Mode

    NASA Astrophysics Data System (ADS)

    Cheng, ZhiPing; Gao, JinFeng; Li, HangYu

    2018-03-01

    The mode switching control of microgrid is the focus of its system control. According to the characteristics of different control, an integrated control system is put forward according to the detecting voltage and frequency deviation after switching of microgrid operating mode. This control system employs master-slave and peer-to-peer control. Wind turbine and photovoltaic(PV) adopt P/Q control, so the maximum power output can be achieved. The energy storage will work under the droop control if the system is grid-connected. When the system is off-grid, whether to employ droop control or P/f control is determined by system status. The simulation has been done and the system performance can meet the requirement.

  2. Beat frequency ultrasonic microsphere contrast agent detection system

    NASA Technical Reports Server (NTRS)

    Pretlow, Robert A., III (Inventor); Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor)

    1995-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  3. Beat frequency ultrasonic microsphere contrast agent detection system

    NASA Technical Reports Server (NTRS)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  4. Herbicides and nitrate in near-surface aquifers in the midcontinental United States, 1991

    USGS Publications Warehouse

    Kolpin, Dana W.; Burkart, Michael R.; Thurman, E. Michael

    1994-01-01

    Hydrogeologic factors, land use, agricultural practices, local features, and water chemistry were analyzed for possible relation to herbicide and excess-nitrate detections. Herbicides and excess nitrate were detected more frequently in near-surface unconsolidated aquifers than in nearsurface bedrock aquifers. The depth to the top of the aquifer was inversely related to the frequency of detection of herbicides and excess nitrate. The proximity of streams to sampled wells also affected the frequency of herbicide detection. Significant seasonal differences were determined for the frequency of herbicide detection, but not for the frequency of excess nitrate.

  5. [Reparative Osteogenesis and Angiogenesis in Low Intensity Electromagnetic Radiation of Ultra-High Frequency].

    PubMed

    Iryanov, Y M; Kiryanov, N A

    2015-01-01

    Non-drug correction of reparative bone tissue regeneration in different pathological states - one of the most actual problems of modern medicine. Our aim was to conduct morphological analysis of the influence of electromagnetic radiation of ultra-high frequency and low intensity on reparative osteogenesis and angiogenesis in fracture treatment under transosseous osteosynthesis. A controlled nonrandomized study was carried out. In the experiment conducted on rats we modeled tibial fracture with reposition and fixation of the bone fragments both in control and experimental groups. In the animals of the experimental group the fracture zone was exposed to low intensity electromagnetic radiation of ultra-high frequency. Exposure simulation was performed in the control group. The operated bones were examined using radiography, light and electronic microscopy, X-ray electronic probe microanalysis. It has been established that electromagnetic radiation of ultra-high frequency sessions in fracture treatment stimulate secretory activity and degranulation of mast cells, produce microcirculatory bed vascular permeability increase, endotheliocyte migration phenotype expression, provide endovascular endothelial outgrowth formation, activate reparative osteogenesis and angiogenesis while fracture reparation becomes the one of the primary type. The full periosteal, intermediary and intraosteal bone union was defined in 28 days. Among the therapeutic benefits of electromagnetic radiation of ultra-high frequency in fracture treatment we can detect mast cell secretorv activity stimulation and endovascular anziozenesis activation.

  6. Tissue reservoirs of antiviral T cell immunity in persistent human CMV infection

    PubMed Central

    Gordon, Claire L.; Thome, Joseph J.C.; Igarashi, Suzu

    2017-01-01

    T cell responses to viruses are initiated and maintained in tissue sites; however, knowledge of human antiviral T cells is largely derived from blood. Cytomegalovirus (CMV) persists in most humans, requires T cell immunity to control, yet tissue immune responses remain undefined. Here, we investigated human CMV-specific T cells, virus persistence and CMV-associated T cell homeostasis in blood, lymphoid, mucosal and secretory tissues of 44 CMV seropositive and 28 seronegative donors. CMV-specific T cells were maintained in distinct distribution patterns, highest in blood, bone marrow (BM), or lymph nodes (LN), with the frequency and function in blood distinct from tissues. CMV genomes were detected predominantly in lung and also in spleen, BM, blood and LN. High frequencies of activated CMV-specific T cells were found in blood and BM samples with low virus detection, whereas in lung, CMV-specific T cells were present along with detectable virus. In LNs, CMV-specific T cells exhibited quiescent phenotypes independent of virus. Overall, T cell differentiation was enhanced in sites of viral persistence with age. Together, our results suggest tissue T cell reservoirs for CMV control shaped by both viral and tissue-intrinsic factors, with global effects on homeostasis of tissue T cells over the lifespan. PMID:28130404

  7. Tissue reservoirs of antiviral T cell immunity in persistent human CMV infection.

    PubMed

    Gordon, Claire L; Miron, Michelle; Thome, Joseph J C; Matsuoka, Nobuhide; Weiner, Joshua; Rak, Michael A; Igarashi, Suzu; Granot, Tomer; Lerner, Harvey; Goodrum, Felicia; Farber, Donna L

    2017-03-06

    T cell responses to viruses are initiated and maintained in tissue sites; however, knowledge of human antiviral T cells is largely derived from blood. Cytomegalovirus (CMV) persists in most humans, requires T cell immunity to control, yet tissue immune responses remain undefined. Here, we investigated human CMV-specific T cells, virus persistence and CMV-associated T cell homeostasis in blood, lymphoid, mucosal and secretory tissues of 44 CMV seropositive and 28 seronegative donors. CMV-specific T cells were maintained in distinct distribution patterns, highest in blood, bone marrow (BM), or lymph nodes (LN), with the frequency and function in blood distinct from tissues. CMV genomes were detected predominantly in lung and also in spleen, BM, blood and LN. High frequencies of activated CMV-specific T cells were found in blood and BM samples with low virus detection, whereas in lung, CMV-specific T cells were present along with detectable virus. In LNs, CMV-specific T cells exhibited quiescent phenotypes independent of virus. Overall, T cell differentiation was enhanced in sites of viral persistence with age. Together, our results suggest tissue T cell reservoirs for CMV control shaped by both viral and tissue-intrinsic factors, with global effects on homeostasis of tissue T cells over the lifespan. @Gordon et al.

  8. Inner ear involvement in Behçet's disease.

    PubMed

    Süslü, Ahmet Emre; Polat, Mualla; Köybaşi, Serap; Biçer, Yusuf Ozgür; Funda, Yasemin Ongun; Parlak, Ali Haydar

    2010-06-01

    To assess cochlear involvement and hearing loss in patients with Behçet's disease (BD). Forty-two patients with BD and 24 sex and age matched healthy subjects were included in the study. pure-tone audiometry including high frequencies (250-16000Hz) and DPOAE were performed to all participants. Results of the audiological evaluation were compared and correlation between the audiologic status and clinical manifestations of the BD were investigated. Bilateral sensorineural hearing loss was detected in 27 (64.3%) patients. Hearing thresholds were found to be higher in patients with BD at all of the frequencies except at 500Hz when compared to control group (p<0.05). The difference in the hearing levels tend to increase in high frequencies. Compared with control group, distortion products and SNR of the BD patients were lower in all of the tested frequencies (p<0.05) which indicates weaker outer hair cell motility. There was no correlation between the clinical manifestations and the audiological parameters. Even having hearing levels within normal limits in speech frequencies, increased hearing thresholds in high frequencies and decreased signal-noise ratios (SNR) in distortion product otoacoustic emission (DPOAE) indicate a cochlear involvement in patients with BD. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  9. A 24-GHz portable FMCW radar with continuous beam steering phased array (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Peng, Zhengyu; Li, Changzhi

    2017-05-01

    A portable 24-GHz frequency-modulated continuous-wave (FMCW) radar with continuous beam steering phased array is presented. This board-level integrated radar system consists of a phased array antenna, a radar transceiver and a baseband. The phased array used by the receiver is a 4-element linear array. The beam of the phased array can be continuously steered with a range of ±30° on the H-plane through an array of vector controllers. The vector controller is based on the concept of vector sum with binary-phase-shift attenuators. Each vector controller is capable of independently controlling the phase and the amplitude of each element of the linear array. The radar transceiver is based on the six-port technique. A free-running voltage controlled oscillator (VCO) is controlled by an analog "sawtooth" voltage generator to produce frequency-modulated chirp signal. This chirp signal is used as the transmitter signal, as well as the local oscillator (LO) signal to drive the six-port circuit. The transmitter antenna is a single patch antenna. In the baseband, the beat signal of the FMCW radar is detected by the six-port circuit and then processed by a laptop in real time. Experiments have been performed to reveal the capabilities of the proposed radar system for applications including indoor inverse synthetic aperture radar (ISAR) imaging, vital sign detection, and short-range navigation, etc. (This abstract is for the profiles session.)

  10. Design and performance of the collective Thomson scattering receiver at ASDEX Upgrade.

    PubMed

    Furtula, V; Salewski, M; Leipold, F; Michelsen, P K; Korsholm, S B; Meo, F; Moseev, D; Nielsen, S K; Stejner, M; Johansen, T

    2012-01-01

    Here we present the design of the fast-ion collective Thomson scattering receiver for millimeter wave radiation installed at ASDEX Upgrade, a tokamak for fusion plasma experiments. The receiver can detect spectral power densities of a few eV against the electron cyclotron emission background on the order of 100 eV under presence of gyrotron stray radiation that is several orders of magnitude stronger than the signal to be detected. The receiver down converts the frequencies of scattered radiation (100-110 GHz) to intermediate frequencies (IF) (4.5-14.5 GHz) by heterodyning. The IF signal is divided into 50 IF channels tightly spaced in frequency space. The channels are terminated by square-law detector diodes that convert the signal power into DC voltages. We present measurements of the transmission characteristics and performance of the main receiver components operating at mm-wave frequencies (notch, bandpass, and lowpass filters, a voltage-controlled variable attenuator, and an isolator), the down-converter unit, and the IF components (amplifiers, bandpass filters, and detector diodes). Furthermore, we determine the performance of the receiver as a unit through spectral response measurements and find reasonable agreement with the expectation based on the individual component measurements.

  11. Scheme for efficient extraction of low-frequency signal beyond the quantum limit by frequency-shift detection.

    PubMed

    Yang, R G; Zhang, J; Zhai, Z H; Zhai, S Q; Liu, K; Gao, J R

    2015-08-10

    Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.

  12. Object detection with a multistatic array using singular value decomposition

    DOEpatents

    Hallquist, Aaron T.; Chambers, David H.

    2014-07-01

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across a surface and that travels down the surface. The detection system converts the return signals from a time domain to a frequency domain, resulting in frequency return signals. The detection system then performs a singular value decomposition for each frequency to identify singular values for each frequency. The detection system then detects the presence of a subsurface object based on a comparison of the identified singular values to expected singular values when no subsurface object is present.

  13. CHIT1 genetic defects in the Portuguese population.

    PubMed

    Duarte, Ana Joana; Ribeiro, Diogo; Amaral, Olga

    2013-01-01

    Chitotriosidase is an enzyme secreted by activated macrophages and a useful biomarker in several lysosomal and nonlysosomal diseases. However, chitotriosidase gene (CHIT1) mutations may lead to inaccuracy in the significance of this biomarker. Reports on the molecular spectrum of genetic variation in chitotriosidase are rare, and this is one of the few that focus on a specific population group. In this work we assessed the variation of CHIT1 mutations in ten normal controls and detected six missense alterations. G102S, a polymorphism with known altered catalytic properties, was the most frequent being detected in 4/10 individuals. Using allelic discrimination we tested 503 individuals, randomly sampled from the Portuguese population. Variant G102S was detected in 49.5% of the individuals and presented an allele frequency of 0.29. The results of this study showed that variability in CHIT1 gene is considerable and that G102S polymorphism presents a high frequency in the Portuguese. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. A high sensitivity real-time NVR monitor. [Nonvolatile Residue

    NASA Technical Reports Server (NTRS)

    Bowers, William D.; Chuan, R. L.

    1992-01-01

    The use of a temperature-controlled 200-MHz SAW resonator piezoelectric mass microbalance to monitor the mass of nonvolatile residue (NVR) deposited on its surface in real time is reported. The fundamental frequency of this device is mainly dependent on the configuration of the transducers and not on the thickness of the substrate. Therefore, higher operating frequencies can be achieved without reducing the thickness of the crystal. The real-time instrument was integrated onto a conventional stainless steel NVR plate and operated flawlessly over a 14-d period at Kennedy Space Center and successfully measured less than 1 ng/sq cm d NVR contamination. Contamination episodes detected by the instrument were correlated with scheduled activities on the test stand. Under the assumption of a baseline noise level of +/- 2 Hz, the absolute mass lower limit of detection would be 0.065 ng/sq cm. This would enable the detection of a daily NVR deposition rate of less than 0.1 ng/sq cm d.

  15. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    NASA Astrophysics Data System (ADS)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  16. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

    PubMed

    Yang, Lin; Dai, Meng; Xu, Canhua; Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen

    2017-01-01

    Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.

  17. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz

    PubMed Central

    Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen

    2017-01-01

    Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects’ heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection. PMID:28107524

  18. Methods and apparatus for broadband frequency comb stabilization

    DOEpatents

    Cox, Jonathan A; Kaertner, Franz X

    2015-03-17

    Feedback loops can be used to shift and stabilize the carrier-envelope phase of a frequency comb from a mode-locked fibers laser or other optical source. Compared to other frequency shifting and stabilization techniques, feedback-based techniques provide a wideband closed-loop servo bandwidth without optical filtering, beam pointing errors, or group velocity dispersion. It also enables phase locking to a stable reference, such as a Ti:Sapphire laser, continuous-wave microwave or optical source, or self-referencing interferometer, e.g., to within 200 mrad rms from DC to 5 MHz. In addition, stabilized frequency combs can be coherently combined with other stable signals, including other stabilized frequency combs, to synthesize optical pulse trains with pulse durations of as little as a single optical cycle. Such a coherent combination can be achieved via orthogonal control, using balanced optical cross-correlation for timing stabilization and balanced homodyne detection for phase stabilization.

  19. Sleep spindle alterations in patients with Parkinson's disease

    PubMed Central

    Christensen, Julie A. E.; Nikolic, Miki; Warby, Simon C.; Koch, Henriette; Zoetmulder, Marielle; Frandsen, Rune; Moghadam, Keivan K.; Sorensen, Helge B. D.; Mignot, Emmanuel; Jennum, Poul J.

    2015-01-01

    The aim of this study was to identify changes of sleep spindles (SS) in the EEG of patients with Parkinson's disease (PD). Five sleep experts manually identified SS at a central scalp location (C3-A2) in 15 PD and 15 age- and sex-matched control subjects. Each SS was given a confidence score, and by using a group consensus rule, 901 SS were identified and characterized by their (1) duration, (2) oscillation frequency, (3) maximum peak-to-peak amplitude, (4) percent-to-peak amplitude, and (5) density. Between-group comparisons were made for all SS characteristics computed, and significant changes for PD patients vs. control subjects were found for duration, oscillation frequency, maximum peak-to-peak amplitude and density. Specifically, SS density was lower, duration was longer, oscillation frequency slower and maximum peak-to-peak amplitude higher in patients vs. controls. We also computed inter-expert reliability in SS scoring and found a significantly lower reliability in scoring definite SS in patients when compared to controls. How neurodegeneration in PD could influence SS characteristics is discussed. We also note that the SS morphological changes observed here may affect automatic detection of SS in patients with PD or other neurodegenerative disorders (NDDs). PMID:25983685

  20. Improvement of charge-pumping electrically detected magnetic resonance and its application to silicon metal-oxide-semiconductor field-effect transistor

    NASA Astrophysics Data System (ADS)

    Hori, Masahiro; Tsuchiya, Toshiaki; Ono, Yukinori

    2017-01-01

    Charge-pumping electrically detected magnetic resonance (CP EDMR), or EDMR in the CP mode, is improved and applied to a silicon metal-oxide-semiconductor field-effect transistor (MOSFET). Real-time monitoring of the CP process reveals that high-frequency transient currents are an obstacle to signal amplification for EDMR. Therefore, we introduce cutoff circuitry, leading to a detection limit for the number of spins as low as 103 for Si MOS interface defects. With this improved method, we demonstrate that CP EDMR inherits one of the most important features of the CP method: the gate control of the energy window of the detectable interface defects for spectroscopy.

  1. Sensorless Sinusoidal Drives for Fan and Pump Motors by V/f Control

    NASA Astrophysics Data System (ADS)

    Kiuchi, Mitsuyuki; Ohnishi, Tokuo

    This paper proposes sensorless sinusoidal driving methods of permanent magnet synchronous motors for fans and pumps by V/f control. The proposed methods are simple methods that control the motor peak current constant by voltage or frequency control, and are characterized by DC link current detection using a single shunt resistor at carrier wave signal bottom timing. As a result of the dumping factor from square torque load characteristics of fan and pump motors, it is possible to control stable starting and stable steady state by V/f control. In general, pressure losses as a result of the fluid pass of fan and pump systems are nearly constant; therefore, the flow rate and motor torque are determined by revolutions. Accordingly, high efficiency driving is possible by setting corresponding currents to q-axis currents (torque currents) at target revolutions. Because of the simple current detection and motor control methods, the proposed methods are optimum for fan and pump motor driving systems of home appliances.

  2. A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whittaker, J. D., E-mail: jwhittaker@dwavesys.com; Swenson, L. J.; Volkmann, M. H.

    Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of bandwidth utilization. Here, we present the design, implementation, and initial characterization of a superconducting microresonator readout integrating two tunable inductances per detector. Wemore » demonstrate that these tuning elements provide independent control of both the detector frequency and sensitivity, allowing us to maximize the transmission line bandwidth utilization. Finally, we discuss the integration of these detectors in a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, highlighting the use of control and routing circuitry composed of single-flux-quantum loops to minimize the number of control wires at the lowest temperature stage.« less

  3. A simple laser locking system based on a field-programmable gate array.

    PubMed

    Jørgensen, N B; Birkmose, D; Trelborg, K; Wacker, L; Winter, N; Hilliard, A J; Bason, M G; Arlt, J J

    2016-07-01

    Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection, and a proportional-integral-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The locking system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements were performed to characterize the system. The linewidth of the locked laser was measured to be 0.7 ± 0.1 MHz with a settling time of 10 ms. The system can thus fully match laser systems currently in use for atom trapping and cooling applications.

  4. A simple laser locking system based on a field-programmable gate array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jørgensen, N. B.; Birkmose, D.; Trelborg, K.

    Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection, and a proportional-integral-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The lockingmore » system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements were performed to characterize the system. The linewidth of the locked laser was measured to be 0.7 ± 0.1 MHz with a settling time of 10 ms. The system can thus fully match laser systems currently in use for atom trapping and cooling applications.« less

  5. Background-free millimeter-wave ultra-wideband signal generation based on a dual-parallel Mach-Zehnder modulator.

    PubMed

    Zhang, Fangzheng; Pan, Shilong

    2013-11-04

    A novel scheme for photonic generation of a millimeter-wave ultra-wideband (MMW-UWB) signal is proposed and experimentally demonstrated based on a dual-parallel Mach-Zehnder modulator (DPMZM). In the proposed scheme, a single-frequency radio frequency (RF) signal is applied to one sub-MZM of the DPMZM to achieve optical suppressed-carrier modulation, and an electrical control pulse train is applied to the other sub-MZM biased at the minimum transmission point, to get an on/off switchable optical carrier. By filtering out the optical carrier with one of the first-order sidebands, and properly setting the amplitude of the control pulse, an MMW-UWB pulse train without the residual local oscillation is generated after photo-detection. The generated MMW-UWB signal is background-free, because the low-frequency components in the electrical spectrum are effectively suppressed. In the experiment, an MMW-UWB pulse train centered at 25 GHz with a 10-dB bandwidth of 5.5 GHz is successfully generated. The low frequency components are suppressed by 22 dB.

  6. Radar network communication through sensing of frequency hopping

    DOEpatents

    Dowla, Farid; Nekoogar, Faranak

    2013-05-28

    In one embodiment, a radar communication system includes a plurality of radars having a communication range and being capable of operating at a sensing frequency and a reporting frequency, wherein the reporting frequency is different than the sensing frequency, each radar is adapted for operating at the sensing frequency until an event is detected, each radar in the plurality of radars has an identification/location frequency for reporting information different from the sensing frequency, a first radar of the radars which senses the event sends a reporting frequency corresponding to its identification/location frequency when the event is detected, and all other radars in the plurality of radars switch their reporting frequencies to match the reporting frequency of the first radar upon detecting the reporting frequency switch of a radar within the communication range. In another embodiment, a method is presented for communicating information in a radar system.

  7. Performance assessment of multi-frequency processing of ICU chest images for enhanced visualization of tubes and catheters

    NASA Astrophysics Data System (ADS)

    Wang, Xiaohui; Couwenhoven, Mary E.; Foos, David H.; Doran, James; Yankelevitz, David F.; Henschke, Claudia I.

    2008-03-01

    An image-processing method has been developed to improve the visibility of tube and catheter features in portable chest x-ray (CXR) images captured in the intensive care unit (ICU). The image-processing method is based on a multi-frequency approach, wherein the input image is decomposed into different spatial frequency bands, and those bands that contain the tube and catheter signals are individually enhanced by nonlinear boosting functions. Using a random sampling strategy, 50 cases were retrospectively selected for the study from a large database of portable CXR images that had been collected from multiple institutions over a two-year period. All images used in the study were captured using photo-stimulable, storage phosphor computed radiography (CR) systems. Each image was processed two ways. The images were processed with default image processing parameters such as those used in clinical settings (control). The 50 images were then separately processed using the new tube and catheter enhancement algorithm (test). Three board-certified radiologists participated in a reader study to assess differences in both detection-confidence performance and diagnostic efficiency between the control and test images. Images were evaluated on a diagnostic-quality, 3-megapixel monochrome monitor. Two scenarios were studied: the baseline scenario, representative of today's workflow (a single-control image presented with the window/level adjustments enabled) vs. the test scenario (a control/test image pair presented with a toggle enabled and the window/level settings disabled). The radiologists were asked to read the images in each scenario as they normally would for clinical diagnosis. Trend analysis indicates that the test scenario offers improved reading efficiency while providing as good or better detection capability compared to the baseline scenario.

  8. Candida albicans and non-albicans species as etiological agent of vaginitis in pregnant and non-pregnant women.

    PubMed

    Babic, Mirela; Hukic, Mirsada

    2010-02-01

    Pregnancy represents a risk factor in the occurrence of vaginal candidosis. The objectives of our study were: to make determination of the microscopic findings of vaginal swab, frequency of Candida species in the culture of pregnant women and patients who are not pregnant, determine the Candida species in all cultures, and to determine the frequency and differences in the frequency of C. albicans and other non-albicans species. In one year study performed during 2006 year, we tested patients of Gynaecology and Obstetrics clinic of the Clinical Centre in Sarajevo and Gynaecology department of the General hospital in Sarajevo. 447 woman included in the study were separated in two groups: 203 pregnant (in the last trimester of pregnancy), and 244 non-pregnant woman in period of fertility. Each vaginal swab was examined microscopically. The yeast, number of colonies, and the species of Candida were determined on Sabouraud dextrose agar with presence of antibiotics. For determination of Candida species, we used germ tube test for detection of C. albicans, and cultivation on the selective medium and assimilation tests for detection of non-albicans species. The results indicated positive microscopic findings in the test group (40,9%), as well as greater number of positive cultures (46,8%). The most commonly detected species for both groups was C. albicans ( test group 40.9% and control group 23,0%). The most commonly detected non-albicans species for the test group were C. glabrata (4,2 %) and C. krusei (3,2%), and for the control group were C. glabrata (3,2%) and C. parapsilosis (3,2%). The microscopic findings correlated with the number of colonies in positive cultures. In the test group, we found an increased number of yeasts (64,3%), and the pseudopyphae and blastopores by microscopic examination as an indication of infection. In the control group, we found a small number of yeasts (64,6%) , in the form of blastopores, as an indication of the candida colonisation. Our results indicate that gravidity, as the risc factor for incidence of infection, has the significant role in the incidence of vaginal candidosis.

  9. Identification of opportunistic enteric parasites among immunocompetent patients with diarrhoea from Northern India and genetic characterisation of Cryptosporidium and Microsporidia.

    PubMed

    Ghoshal, U; Dey, A; Ranjan, P; Khanduja, S; Agarwal, V; Ghoshal, U C

    2016-01-01

    Enteric parasitic infestation is a major public health problem in developing countries. Parasites such as Cryptosporidium spp., Cyclospora spp., Cystoisospora spp. and Microsporidia may cause severe diarrhoea among immunocompromised patients. There is scanty data on their frequency among immunocompetent patients. Accordingly, we studied the frequency of enteric opportunistic parasites among immunocompetent patients with diarrhoea from northern India; we also performed genetic characterisation of Cryptosporidia and Microsporidia among them. Stool samples from 80 immunocompetent patients with diarrhoea, and 110 healthy controls were examined. Parasites were detected by direct microscopy, modified acid-fast (Kinyoun's) and modified trichrome stain. Polymerase chain reaction--restriction fragment length polymorphism was used for genetic characterisation of selected species such as Cryptosporidia and Microsporidia. Enteric parasites were detected in 16/80 (20%) patients (mean age 28.8±20 years, 45, 56% males) and in 2/110 (1.8%) healthy controls (P=0.00007). Parasites detected were Cryptosporidium spp. (8/16, 50.0%), Cystoisospora spp. (4/16, 25%), Microsporidia (1/16, 6.25%), Cyclospora spp. (1/16, 6.25%) and Giardia spp. (1/16, 6.25%). One patient had mixed infection with Cystoisospora spp. and Giardia spp. The species of Cryptosporidia and Microsporidia detected were Cryptosporidium hominis and Enterocytozoon bieneusi, respectively. Parasites were more often detected in younger patients (≤20 years of age) than in older. Most of the parasite infected patients presented with chronic diarrhoea. Opportunistic enteric parasitic infestation was more common among immunocompetent patients with diarrhoea than healthy subjects. Special staining as well as molecular methods are essential for appropriate diagnosis of these parasites.

  10. Phase-locked Optical Signal Recovery

    DTIC Science & Technology

    2009-01-01

    detection . However, implementing an optical phase lock loop ( OPLL ) to generate the synchronised carrier for the homodyne technique requires... Loop (OIPLL) in which a narrow bandwidth optical phase lock loop ( OPLL ) is used to control the free -running frequency of an optically injection...receiver uses an Optical Injection Phase Lock Loop (OIPLL) for carrier recovery,

  11. Phase-locked Optical Signal Recovery

    DTIC Science & Technology

    2009-01-01

    detection . However, implementing an optical phase lock loop ( OPLL ) to generate the synchronised carrier for the homodyne technique requires... Loop (OIPLL) in which a narrow bandwidth optical phase lock loop ( OPLL ) is used to control the free -running frequency of an optically injection...The receiver uses an Optical Injection Phase Lock Loop (OIPLL) for carrier

  12. Developing an active artificial hair cell using nonlinear feedback control

    NASA Astrophysics Data System (ADS)

    Joyce, Bryan S.; Tarazaga, Pablo A.

    2015-09-01

    The hair cells in the mammalian cochlea convert sound-induced vibrations into electrical signals. These cells have inspired a variety of artificial hair cells (AHCs) to serve as biologically inspired sound, fluid flow, and acceleration sensors and could one day replace damaged hair cells in humans. Most of these AHCs rely on passive transduction of stimulus while it is known that the biological cochlea employs active processes to amplify sound-induced vibrations and improve sound detection. In this work, an active AHC mimics the active, nonlinear behavior of the cochlea. The AHC consists of a piezoelectric bimorph beam subjected to a base excitation. A feedback control law is used to reduce the linear damping of the beam and introduce a cubic damping term which gives the AHC the desired nonlinear behavior. Model and experimental results show the AHC amplifies the response due to small base accelerations, has a higher frequency sensitivity than the passive system, and exhibits a compressive nonlinearity like that of the mammalian cochlea. This bio-inspired accelerometer could lead to new sensors with lower thresholds of detection, improved frequency sensitivities, and wider dynamic ranges.

  13. Increased levels of lead in the blood and frequencies of lymphocytic micronucleated binucleated cells among workers from an electronic-waste recycling site.

    PubMed

    Wang, Qian; He, An M; Gao, Bo; Chen, Lan; Yu, Qiang Z; Guo, Huan; Shi, Bin J; Jiang, Pu; Zhang, Zeng Y; Li, Ping L; Sheng, Ying G; Fu, Mo J; Wu, Chun T; Chen, Min X; Yuan, Jing

    2011-01-01

    In recent years, adverse health effects of chemicals from electronic waste (e-waste) have been reported. However, little is known about the genotoxic effects of chemicals in e-waste. In the present study, air concentrations of the toxic metals at e-waste and control sites were analyzed using inductively-coupled plasma mass spectrometry. Levels of toxic metals (lead, copper and cadmium) in blood and urine were detected using atomic absorption spectrophotometry in 48 exposed individuals and 56 age- and sex-matched controls. The frequencies of lymphocytic micronucleated binucleated cells (MNBNCs) were determined using a cytokinesis-block micronucleus assay. Results indicated that blood lead levels were significantly higher in the exposed group (median: 11.449 μg/dL, 1st/3rd quartiles: 9.351-14.410 μg/dL) than in the control group (median: 9.104 μg/dL, 1st/3rd quartiles: 7.275-11.389 μg/dL). The exposed group had higher MNBNCs frequencies (median: 4.0 per thousand, 1st/3rd quartiles: 2.0-7.0 per thousand) compared with the controls (median: 1.0 per thousand, 1st/3rd quartiles: 0.0-2.0 per thousand). Additionally, MNBNCs frequencies and blood lead levels were positively correlated (r = 0.254, p<0.01). Further analysis suggested that a history of working with e-waste was a predictor for increased blood lead levels and MNBNCs frequencies in the subjects. The results suggest that both the living and occupational environments at the e-waste site may be risk factors for increased MNBNCs frequencies among those who are exposed.

  14. Dissolved pesticides, dissolved organic carbon, and water-quality characteristics in selected Idaho streams, April--December 2010

    USGS Publications Warehouse

    Reilly, Timothy J.; Smalling, Kelly L.; Wilson, Emma R.; Battaglin, William A.

    2012-01-01

    Water-quality samples were collected from April through December 2010 from four streams in Idaho and analyzed for a suite of pesticides, including fungicides, by the U.S. Geological Survey. Water samples were collected from two agricultural and two nonagricultural (control) streams approximately biweekly from the beginning of the growing season (April) through the end of the calendar year (December). Samples were analyzed for 90 pesticides using gas chromatography/mass spectrometry. Twenty-three pesticides, including 8 fungicides, 10 herbicides, 3 insecticides, and 2 pesticide degradates, were detected in 45 water samples. The most frequently detected compounds in the two agricultural streams and their detection frequencies were metolachlor, 96 percent; azoxystrobin, 79 percent; boscalid, 79 percent; atrazine, 46 percent; pendimethalin, 33 percent; and trifluralin, 33 percent. Dissolved-pesticide concentrations ranged from below instrumental limits of detection (0.5-1.0 nanograms per liter) to 771 nanograms per liter (hexazinone). The total number of pesticides detected in any given water sample ranged from 0 to 11. Only three pesticides (atrazine, fipronil, and simazine) were detected in samples from the control streams during the sampling period.

  15. Cocaine effects on pulsatile secretion of anterior pituitary, gonadal, and adrenal hormones.

    PubMed

    Mendelson, J H; Mello, N K; Teoh, S K; Ellingboe, J; Cochin, J

    1989-12-01

    Pulse frequency analysis of LH, PRL, testosterone, and cortisol was carried out with the Cluster Analysis Program in eight male cocaine abusers and eight aged-matched normal men. Four of the eight cocaine abusers had hyperprolactinemia (range, 22.08-44.65 micrograms/L). Cocaine users as a group had significantly higher mean peak height (P less than 0.02) than control subjects. Cocaine users with hyperprolactinemia had higher mean peak height than control subjects or cocaine users with normal PRL levels (P less than 0.01). Cocaine users with hyperprolactinemia also had higher mean amplitude increments than control subjects (P less than 0.02). Cocaine users with hyperprolactinemia had a higher mean valley than controls (P less than 0.01) and cocaine users with normal PRL levels (P less than 0.03). However, there were no significant differences in PRL peak frequency, peak duration, or interpulse intervals between cocaine users with or without hyperprolactinemia and control subjects. There were minimal differences between cocaine users and control subjects in pulse frequency analysis of LH parameters; the small differences in mean LH levels and average interpulse interval were not in the abnormal range and were probably not biologically significant. No differences between cocaine users and controls were detected for pulse frequency analysis of testosterone or cortisol. Cocaine-induced hyperprolactinemia may contribute to disorders of sexual and reproductive function in men who abuse the drug, and recent reports that PRL modulates immune function suggest that cocaine-induced derangements of PRL secretion may also contribute to cocaine-related comorbidity in infectious disease. Since cocaine users with hyperprolactinemia had a higher mean valley as well as a higher peak pulse PRL height than control subjects, but did not have greater PRL pulse frequencies, we conclude that hyperprolactinemia in these men may be due to a cocaine-induced derangement of dopaminergic inhibition of basal PRL secretion.

  16. Frequency and significance of parvovirus B19 infection in patients with rheumatoid arthritis.

    PubMed

    Naciute, Milda; Mieliauskaite, Diana; Rugiene, Rita; Nikitenkiene, Rita; Jancoriene, Ligita; Mauricas, Mykolas; Nora-Krukle, Zaiga; Murovska, Modra; Girkontaite, Irute

    2016-12-01

    The present study aims to clarify the possible involvement of parvovirus B19 (B19V) infection in rheumatoid arthritis (RA) pathogenesis by investigating the presence of B19V infection markers (genomic sequences and virus-specific antibodies) in association with the level of cytokines and RA clinical activity and aggressiveness. A total of 118 RA patients and 49 age- and sex-matched healthy volunteers were enrolled in the study. Nested PCR was used to detect B19V sequences in whole blood and cell-free plasma DNA, ELISA to detect virus-specific antibodies and cytokine levels in plasma and recomLine dot blot assay for antibodies to separate B19V antigens. The detection frequency of B19V DNA was higher in patients with RA (25.4 %) in comparison with healthy persons (18.4 %). B19V DNA in cell-free plasma (B19+p) was detected significantly often in RA patients in comparison with healthy controls (13.6 vs 2 %; P=0.0002). RA B19+p patients had higher disease activity and aggressiveness, decreased haemoglobin and increased erythrocyte sedimentation rates. IL-6 plasma levels were significantly higher in RA patients than in controls. Within the RA patients' group the IL-6 level was significantly increased in B19+p patients with disease activity scores of DAS28>5.2, high C-reactive protein and low haemoglobin. Contrary to the healthy controls, the majority of RA B19+p patients did not have antibodies to VP-1S (VP1u) and VP-N (N-terminal half of structural proteins VP1 and VP2), which correspond to the epitopes of neutralizing antibodies. These results indicate that B19V infection at least in some patients is involved in RA pathogenesis.

  17. [Genetic polymorphisms of ARL15 and HLA-DMA are associated with rheumatoid arthritis in Han population from northwest China].

    PubMed

    Wang, Jiao; Qi, Xiaoming; Zhang, Xiaozhen; Yan, Wen; You, Chongge

    2017-12-01

    Objective To establish the methods for detecting single nucleotide polymorphisms (SNPs) of ADP-ribosylation factor-like GTPase 15 (ARL15), major histocompatibility complex class II-DM alpha (HLA-DMA ) and nuclear factor kappa B subunit 2 (NFKB2) genes using high resolution melting (HRM) technology, and to explore the association of those SNPs with the susceptibility of rheumatoid arthritis (RA) in northwestern Han Chinese population. Methods The PCR-HRM detection system for four SNPs (rs255758, rs1063478, rs397514331 and rs397514332) was established for genotyping, and gene sequencing was performed to validate the genotyping ability of the system. 588 RA cases and 200 controls were enrolled in a case-control study to analyze the associations of ARL15 and HLA-DMA gene polymorphisms with RA risk. Results The direct sequencing validated that the established PCR-HRM detection system could be used for genotyping clinical samples correctly. The mutated genotype of rs397514331 and rs397514332 from NFKB2 gene are not found in this study. The genotype frequencies of rs255758 and rs1063478 had statistical difference between the cases and controls, but no statistical difference in allelic frequencies. Under the dominant model (AA vs AC/CC), the AA genotype of rs255758 decreases the RA risk (OR=0.666, 95%CI=0.478-0.927, P=0.016). Conclusion The method of PCR-HRM we established can be applied to the routine detection of rs255758, rs1063478, rs397514331 and rs397514332. The ARL15 and HLA-DMA gene polymorphisms are associated with RA risk in Northwestern Han Chinese population.

  18. Gap detection threshold in the rat before and after auditory cortex ablation.

    PubMed

    Syka, J; Rybalko, N; Mazelová, J; Druga, R

    2002-10-01

    Gap detection threshold (GDT) was measured in adult female pigmented rats (strain Long-Evans) by an operant conditioning technique with food reinforcement, before and after bilateral ablation of the auditory cortex. GDT was dependent on the frequency spectrum and intensity of the continuously present noise in which the gaps were embedded. The mean values of GDT for gaps embedded in white noise or low-frequency noise (upper cutoff frequency 3 kHz) at 70 dB sound pressure level (SPL) were 1.57+/-0.07 ms and 2.9+/-0.34 ms, respectively. Decreasing noise intensity from 80 dB SPL to 20 dB SPL produced a significant increase in GDT. The increase in GDT was relatively small in the range of 80-50 dB SPL for white noise and in the range of 80-60 dB for low-frequency noise. The minimal intensity level of the noise that enabled GDT measurement was 20 dB SPL for white noise and 30 dB SPL for low-frequency noise. Mean GDT values at these intensities were 10.6+/-3.9 ms and 31.3+/-4.2 ms, respectively. Bilateral ablation of the primary auditory cortex (complete destruction of the Te1 and partial destruction of the Te2 and Te3 areas) resulted in an increase in GDT values. The fifth day after surgery, the rats were able to detect gaps in the noise. The values of GDT observed at this time were 4.2+/-1.1 ms for white noise and 7.4+/-3.1 ms for low-frequency noise at 70 dB SPL. During the first month after cortical ablation, recovery of GDT was observed. However, 1 month after cortical ablation GDT still remained slightly higher than in controls (1.8+/-0.18 for white noise, 3.22+/-0.15 for low-frequency noise, P<0.05). A decrease in GDT values during the subsequent months was not observed.

  19. Fly Eye radar: detection through high scattered media

    NASA Astrophysics Data System (ADS)

    Molchanov, Pavlo; Gorwara, Ashok

    2017-05-01

    Longer radio frequency waves better penetrating through high scattered media than millimeter waves, but imaging resolution limited by diffraction at longer wavelength. Same time frequency and amplitudes of diffracted waves (frequency domain measurement) provides information of object. Phase shift of diffracted waves (phase front in time domain) consists information about shape of object and can be applied for reconstruction of object shape or even image by recording of multi-frequency digital hologram. Spectrum signature or refracted waves allows identify the object content. Application of monopulse method with overlap closely spaced antenna patterns provides high accuracy measurement of amplitude, phase, and direction to signal source. Digitizing of received signals separately in each antenna relative to processor time provides phase/frequency independence. Fly eye non-scanning multi-frequency radar system provides simultaneous continuous observation of multiple targets and wide possibilities for stepped frequency, simultaneous frequency, chaotic frequency sweeping waveform (CFS), polarization modulation for reliable object detection. Proposed c-band fly eye radar demonstrated human detection through 40 cm concrete brick wall with human and wall material spectrum signatures and can be applied for through wall human detection, landmines, improvised explosive devices detection, underground or camouflaged object imaging.

  20. Between-Frequency and Between-Ear Gap Detections and Their Relation to Perception of Stop Consonants.

    PubMed

    Mori, Shuji; Oyama, Kazuki; Kikuchi, Yousuke; Mitsudo, Takako; Hirose, Nobuyuki

    2015-01-01

    The objective of this study was to examine the hypothesis that between-channel gap detection, which includes between-frequency and between-ear gap detection, and perception of stop consonants, which is mediated by the length of voice-onset time (VOT), share common mechanisms, namely relative-timing operation in monitoring separate perceptual channels. The authors measured gap detection thresholds and identification functions of /ba/ and /pa/ along VOT in 49 native young adult Japanese listeners. There were three gap detection tasks. In the between-frequency task, the leading and trailing markers differed in terms of center frequency (Fc). The leading marker was a broadband noise of 10 to 20,000 Hz. The trailing marker was a 0.5-octave band-passed noise of 1000-, 2000-, 4000-, or 8000-Hz Fc. In the between-ear task, the two markers were spectrally identical but presented to separate ears. In the within-frequency task, the two spectrally identical markers were presented to the same ear. The /ba/-/pa/ identification functions were obtained in a task in which the listeners were presented synthesized speech stimuli of varying VOTs from 10 to 46 msec and asked to identify them as /ba/ or /pa/. The between-ear gap thresholds were significantly positively correlated with the between-frequency gap thresholds (except those obtained with the trailing marker of 4000-Hz Fc). The between-ear gap thresholds were not significantly correlated with the within-frequency gap thresholds, which were significantly correlated with all the between-frequency gap thresholds. The VOT boundaries and slopes of /ba/-/pa/ identification functions were not significantly correlated with any of these gap thresholds. There was a close relation between the between-ear and between-frequency gap detection, supporting the view that these two types of gap detection share common mechanisms of between-channel gap detection. However, there was no evidence for a relation between the perception of stop consonants and the between-frequency/ear gap detection in native Japanese speakers.

  1. Solar Photovoltaic (PV) Distributed Generation Systems - Control and Protection

    NASA Astrophysics Data System (ADS)

    Yi, Zhehan

    This dissertation proposes a comprehensive control, power management, and fault detection strategy for solar photovoltaic (PV) distribution generations. Battery storages are typically employed in PV systems to mitigate the power fluctuation caused by unstable solar irradiance. With AC and DC loads, a PV-battery system can be treated as a hybrid microgrid which contains both DC and AC power resources and buses. In this thesis, a control power and management system (CAPMS) for PV-battery hybrid microgrid is proposed, which provides 1) the DC and AC bus voltage and AC frequency regulating scheme and controllers designed to track set points; 2) a power flow management strategy in the hybrid microgrid to achieve system generation and demand balance in both grid-connected and islanded modes; 3) smooth transition control during grid reconnection by frequency and phase synchronization control between the main grid and microgrid. Due to the increasing demands for PV power, scales of PV systems are getting larger and fault detection in PV arrays becomes challenging. High-impedance faults, low-mismatch faults, and faults occurred in low irradiance conditions tend to be hidden due to low fault currents, particularly, when a PV maximum power point tracking (MPPT) algorithm is in-service. If remain undetected, these faults can considerably lower the output energy of solar systems, damage the panels, and potentially cause fire hazards. In this dissertation, fault detection challenges in PV arrays are analyzed in depth, considering the crossing relations among the characteristics of PV, interactions with MPPT algorithms, and the nature of solar irradiance. Two fault detection schemes are then designed as attempts to address these technical issues, which detect faults inside PV arrays accurately even under challenging circumstances, e.g., faults in low irradiance conditions or high-impedance faults. Taking advantage of multi-resolution signal decomposition (MSD), a powerful signal processing technique based on discrete wavelet transformation (DWT), the first attempt is devised, which extracts the features of both line-to-line (L-L) and line-to-ground (L-G) faults and employs a fuzzy inference system (FIS) for the decision-making stage of fault detection. This scheme is then improved as the second attempt by further studying the system's behaviors during L-L faults, extracting more efficient fault features, and devising a more advanced decision-making stage: the two-stage support vector machine (SVM). For the first time, the two-stage SVM method is proposed in this dissertation to detect L-L faults in PV system with satisfactory accuracies. Numerous simulation and experimental case studies are carried out to verify the proposed control and protection strategies. Simulation environment is set up using the PSCAD/EMTDC and Matlab/Simulink software packages. Experimental case studies are conducted in a PV-battery hybrid microgrid using the dSPACE real-time controller to demonstrate the ease of hardware implementation and the controller performance. Another small-scale grid-connected PV system is set up to verify both fault detection algorithms which demonstrate promising performances and fault detecting accuracies.

  2. Imaging-based molecular barcoding with pixelated dielectric metasurfaces

    NASA Astrophysics Data System (ADS)

    Tittl, Andreas; Leitis, Aleksandrs; Liu, Mingkai; Yesilkoy, Filiz; Choi, Duk-Yong; Neshev, Dragomir N.; Kivshar, Yuri S.; Altug, Hatice

    2018-06-01

    Metasurfaces provide opportunities for wavefront control, flat optics, and subwavelength light focusing. We developed an imaging-based nanophotonic method for detecting mid-infrared molecular fingerprints and implemented it for the chemical identification and compositional analysis of surface-bound analytes. Our technique features a two-dimensional pixelated dielectric metasurface with a range of ultrasharp resonances, each tuned to a discrete frequency; this enables molecular absorption signatures to be read out at multiple spectral points, and the resulting information is then translated into a barcode-like spatial absorption map for imaging. The signatures of biological, polymer, and pesticide molecules can be detected with high sensitivity, covering applications such as biosensing and environmental monitoring. Our chemically specific technique can resolve absorption fingerprints without the need for spectrometry, frequency scanning, or moving mechanical parts, thereby paving the way toward sensitive and versatile miniaturized mid-infrared spectroscopy devices.

  3. Coherent Excitation of Optical Phonons in GaAs by Broadband Terahertz Pulses

    PubMed Central

    Fu, Zhengping; Yamaguchi, Masashi

    2016-01-01

    Coherent excitation and control of lattice motion by electromagnetic radiation in optical frequency range has been reported through variety of indirect interaction mechanisms with phonon modes. However, coherent phonon excitation by direct interaction of electromagnetic radiation and nuclei has not been demonstrated experimentally in terahertz (THz) frequency range mainly due to the lack of THz emitters with broad bandwidth suitable for the purpose. We report the experimental observation of coherent phonon excitation and detection in GaAs using ultrafast THz-pump/optical-probe scheme. From the results of THz pump field dependence, pump/probe polarization dependence, and crystal orientation dependence, we attributed THz wave absorption and linear electro-optic effect to the excitation and detection mechanisms of coherent polar TO phonons. Furthermore, the carrier density dependence of the interaction of coherent phonons and free carriers is reported. PMID:27905563

  4. Amplitude modulation detection with concurrent frequency modulation.

    PubMed

    Nagaraj, Naveen K

    2016-09-01

    Human speech consists of concomitant temporal modulations in amplitude and frequency that are crucial for speech perception. In this study, amplitude modulation (AM) detection thresholds were measured for 550 and 5000 Hz carriers with and without concurrent frequency modulation (FM), at AM rates crucial for speech perception. Results indicate that adding 40 Hz FM interferes with AM detection, more so for 5000 Hz carrier and for frequency deviations exceeding the critical bandwidth of the carrier frequency. These findings suggest that future cochlear implant processors, encoding speech fine-structures may consider limiting the FM to narrow bandwidth and to low frequencies.

  5. Effects of sleep bruxism related tinnitus on quality of life.

    PubMed

    Saltürk, Ziya; Özçelik, Erdinç; Kumral, Tolgar Lütfi; Çakır, Ozan; Kasımoğlu, Şeref; Atar, Yavuz; Yıldırım, Güven; Berkiten, Güler; Göker, Ayşe Enise; Uyar, Yavuz

    2015-01-01

    This study aims to analyze the subjective and objective characteristics of tinnitus in sleep bruxism patients. The study included 57 patients (12 males; 45 females; mean age 33.89±12.50 years; range 19 to 55 years) with sleep bruxism and tinnitus (sleep bruxism group) and 24 patients (6 males, 18 females; mean age 43.75±16.19 years; range 21 to 58 years) only with tinnitus (control group). Sleep bruxism was diagnosed by the diagnostic criteria of American Academy of Sleep Medicine. Patients were performed pure tone audiometry to detect hearing thresholds at standard and high frequencies. Tinnitus frequency and loudness were assessed. Subjective aspects of tinnitus were identified by tinnitus handicap inventory. The statistical analysis revealed that the sleep bruxism group had significantly lower hearing thresholds except 1000 Hz and 2000 Hz. Tinnitus frequency was between 3000 Hz and 18000 Hz in sleep bruxism group while it was between 6000 and 16000 Hz in control group with no statistically significant difference (p=0.362). Sleep bruxism group had significantly lower tinnitus loudness and tinnitus handicap inventory scores in comparison to control group (p=0.024 and p=0.000, respectively). Tinnitus caused by sleep bruxism and temporomandibular joint issues has higher frequency and lower loudness compared to patients with only tinnitus.

  6. Frequency hopping signal detection based on wavelet decomposition and Hilbert-Huang transform

    NASA Astrophysics Data System (ADS)

    Zheng, Yang; Chen, Xihao; Zhu, Rui

    2017-07-01

    Frequency hopping (FH) signal is widely adopted by military communications as a kind of low probability interception signal. Therefore, it is very important to research the FH signal detection algorithm. The existing detection algorithm of FH signals based on the time-frequency analysis cannot satisfy the time and frequency resolution requirement at the same time due to the influence of window function. In order to solve this problem, an algorithm based on wavelet decomposition and Hilbert-Huang transform (HHT) was proposed. The proposed algorithm removes the noise of the received signals by wavelet decomposition and detects the FH signals by Hilbert-Huang transform. Simulation results show the proposed algorithm takes into account both the time resolution and the frequency resolution. Correspondingly, the accuracy of FH signals detection can be improved.

  7. Global warming alters sound transmission: differential impact on the prey detection ability of echolocating bats

    PubMed Central

    Luo, Jinhong; Koselj, Klemen; Zsebők, Sándor; Siemers, Björn M.; Goerlitz, Holger R.

    2014-01-01

    Climate change impacts the biogeography and phenology of plants and animals, yet the underlying mechanisms are little known. Here, we present a functional link between rising temperature and the prey detection ability of echolocating bats. The maximum distance for echo-based prey detection is physically determined by sound attenuation. Attenuation is more pronounced for high-frequency sound, such as echolocation, and is a nonlinear function of both call frequency and ambient temperature. Hence, the prey detection ability, and thus possibly the foraging efficiency, of echolocating bats and susceptible to rising temperatures through climate change. Using present-day climate data and projected temperature rises, we modelled this effect for the entire range of bat call frequencies and climate zones around the globe. We show that depending on call frequency, the prey detection volume of bats will either decrease or increase: species calling above a crossover frequency will lose and species emitting lower frequencies will gain prey detection volume, with crossover frequency and magnitude depending on the local climatic conditions. Within local species assemblages, this may cause a change in community composition. Global warming can thus directly affect the prey detection ability of individual bats and indirectly their interspecific interactions with competitors and prey. PMID:24335559

  8. Global warming alters sound transmission: differential impact on the prey detection ability of echolocating bats.

    PubMed

    Luo, Jinhong; Koselj, Klemen; Zsebok, Sándor; Siemers, Björn M; Goerlitz, Holger R

    2014-02-06

    Climate change impacts the biogeography and phenology of plants and animals, yet the underlying mechanisms are little known. Here, we present a functional link between rising temperature and the prey detection ability of echolocating bats. The maximum distance for echo-based prey detection is physically determined by sound attenuation. Attenuation is more pronounced for high-frequency sound, such as echolocation, and is a nonlinear function of both call frequency and ambient temperature. Hence, the prey detection ability, and thus possibly the foraging efficiency, of echolocating bats and susceptible to rising temperatures through climate change. Using present-day climate data and projected temperature rises, we modelled this effect for the entire range of bat call frequencies and climate zones around the globe. We show that depending on call frequency, the prey detection volume of bats will either decrease or increase: species calling above a crossover frequency will lose and species emitting lower frequencies will gain prey detection volume, with crossover frequency and magnitude depending on the local climatic conditions. Within local species assemblages, this may cause a change in community composition. Global warming can thus directly affect the prey detection ability of individual bats and indirectly their interspecific interactions with competitors and prey.

  9. Low frequency aeration of pig slurry affects slurry characteristics and emissions of greenhouse gases and ammonia.

    PubMed

    Calvet, Salvador; Hunt, John; Misselbrook, Tom H

    2017-07-01

    Low frequency aeration of slurries may reduce ammonia (NH 3 ) and methane (CH 4 ) emissions without increasing nitrous oxide (N 2 O) emissions. The aim of this study was to quantify this potential reduction and to establish the underlying mechanisms. A batch experiment was designed with 6 tanks with 1 m 3 of pig slurry each. After an initial phase of 7 days when none of the tanks were aerated, a second phase of 4 weeks subjected three of the tanks to aeration (2 min every 6 h, airflow 10 m 3  h -1 ), whereas the other three tanks remained as a control. A final phase of 9 days was established with no aeration in any tank. Emissions of NH 3 , CH 4 , carbon dioxide (CO 2 ) and N 2 O were measured. In the initial phase no differences in emissions were detected, but during the second phase aeration increased NH 3 emissions by 20% with respect to the controls (8.48 vs. 7.07 g m -3  [slurry] d -1 , P < 0.05). A higher pH was found in the aerated tanks at the end of this phase (7.7 vs. 7.0 in the aerated and control tanks, respectively, P < 0.05). CH 4 emissions were 40% lower in the aerated tanks (2.04 vs. 3.39 g m -3  [slurry] d -1 , P < 0.05). These differences in NH 3 and CH 4 emissions remained after the aeration phase had finished. No effect was detected for CO 2 , and no relevant N 2 O emissions were detected during the experiment. Our results demonstrate that low frequency aeration of stored pig slurry increases slurry pH and increases NH 3 emissions.

  10. Design of Dual-Mode Local Oscillators Using CMOS Technology for Motion Detection Sensors.

    PubMed

    Ha, Keum-Won; Lee, Jeong-Yun; Kim, Jeong-Geun; Baek, Donghyun

    2018-04-01

    Recently, studies have been actively carried out to implement motion detecting sensors by applying radar techniques. Doppler radar or frequency-modulated continuous wave (FMCW) radar are mainly used, but each type has drawbacks. In Doppler radar, no signal is detected when the movement is stopped. Also, FMCW radar cannot function when the detection object is near the sensor. Therefore, by implementing a single continuous wave (CW) radar for operating in dual-mode, the disadvantages in each mode can be compensated for. In this paper, a dual mode local oscillator (LO) is proposed that makes a CW radar operate as a Doppler or FMCW radar. To make the dual-mode LO, a method that controls the division ratio of the phase locked loop (PLL) is used. To support both radar mode easily, the proposed LO is implemented by adding a frequency sweep generator (FSG) block to a fractional-N PLL. The operation mode of the LO is determined by according to whether this block is operating or not. Since most radar sensors are used in conjunction with microcontroller units (MCUs), the proposed architecture is capable of dual-mode operation by changing only the input control code. In addition, all components such as VCO, LDO, and loop filter are integrated into the chip, so complexity and interface issues can be solved when implementing radar sensors. Thus, the proposed dual-mode LO is suitable as a radar sensor.

  11. Design of Dual-Mode Local Oscillators Using CMOS Technology for Motion Detection Sensors

    PubMed Central

    Lee, Jeong-Yun; Kim, Jeong-Geun

    2018-01-01

    Recently, studies have been actively carried out to implement motion detecting sensors by applying radar techniques. Doppler radar or frequency-modulated continuous wave (FMCW) radar are mainly used, but each type has drawbacks. In Doppler radar, no signal is detected when the movement is stopped. Also, FMCW radar cannot function when the detection object is near the sensor. Therefore, by implementing a single continuous wave (CW) radar for operating in dual-mode, the disadvantages in each mode can be compensated for. In this paper, a dual mode local oscillator (LO) is proposed that makes a CW radar operate as a Doppler or FMCW radar. To make the dual-mode LO, a method that controls the division ratio of the phase locked loop (PLL) is used. To support both radar mode easily, the proposed LO is implemented by adding a frequency sweep generator (FSG) block to a fractional-N PLL. The operation mode of the LO is determined by according to whether this block is operating or not. Since most radar sensors are used in conjunction with microcontroller units (MCUs), the proposed architecture is capable of dual-mode operation by changing only the input control code. In addition, all components such as VCO, LDO, and loop filter are integrated into the chip, so complexity and interface issues can be solved when implementing radar sensors. Thus, the proposed dual-mode LO is suitable as a radar sensor. PMID:29614777

  12. Laser source for dimensional metrology: investigation of an iodine stabilized system based on narrow linewidth 633 nm DBR diode

    NASA Astrophysics Data System (ADS)

    Rerucha, Simon; Yacoot, Andrew; Pham, Tuan M.; Cizek, Martin; Hucl, Vaclav; Lazar, Josef; Cip, Ondrej

    2017-04-01

    We demonstrated that an iodine stabilized distributed Bragg reflector (DBR) diode based laser system lasing at a wavelength in close proximity to λ =633 nm could be used as an alternative laser source to the helium-neon lasers in both scientific and industrial metrology. This yields additional advantages besides the optical frequency stability and coherence: inherent traceability, wider optical frequency tuning range, higher output power and high frequency modulation capability. We experimentally investigated the characteristics of the laser source in two major steps: first using a wavelength meter referenced to a frequency comb controlled with a hydrogen maser and then on an interferometric optical bench testbed where we compared the performance of the laser system with that of a traditional frequency stabilized He-Ne laser. The results indicate that DBR diode laser system provides a good laser source for applications in dimensional (nano)metrology, especially in conjunction with novel interferometric detection methods exploiting high frequency modulation or multiaxis measurement systems.

  13. Assessment of Time and Frequency Domain Parameters of Heart Rate Variability and Interictal Cardiac Rhythm Abnormalities in Drug-naïve Patients with Idiopathic Generalized Epilepsy.

    PubMed

    Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye

    2016-06-01

    Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures.

  14. Binaural auditory beats affect vigilance performance and mood.

    PubMed

    Lane, J D; Kasian, S J; Owens, J E; Marsh, G R

    1998-01-01

    When two tones of slightly different frequency are presented separately to the left and right ears the listener perceives a single tone that varies in amplitude at a frequency equal to the frequency difference between the two tones, a perceptual phenomenon known as the binaural auditory beat. Anecdotal reports suggest that binaural auditory beats within the electroencephalograph frequency range can entrain EEG activity and may affect states of consciousness, although few scientific studies have been published. This study compared the effects of binaural auditory beats in the EEG beta and EEG theta/delta frequency ranges on mood and on performance of a vigilance task to investigate their effects on subjective and objective measures of arousal. Participants (n = 29) performed a 30-min visual vigilance task on three different days while listening to pink noise containing simple tones or binaural beats either in the beta range (16 and 24 Hz) or the theta/delta range (1.5 and 4 Hz). However, participants were kept blind to the presence of binaural beats to control expectation effects. Presentation of beta-frequency binaural beats yielded more correct target detections and fewer false alarms than presentation of theta/delta frequency binaural beats. In addition, the beta-frequency beats were associated with less negative mood. Results suggest that the presentation of binaural auditory beats can affect psychomotor performance and mood. This technology may have applications for the control of attention and arousal and the enhancement of human performance.

  15. Frequencies of neuronal autoantibodies in healthy controls

    PubMed Central

    Lang, Katharina

    2017-01-01

    Objective: To provide an extensive overview on the prevalence of antibodies against neuronal surfaces (neuronal surface antibody [NSAb]) in healthy participants and disease controls. Methods: We searched the PubMed database (1974 to October 2016) for studies that analyzed frequencies of 22 different NSAbs in serum or CSF and included controls. Antibody prevalence was calculated for patients with NSAb-mediated disease and controls, including healthy participants, and those with neurologic and nonneurologic diseases. Different assays for antibody detection were compared. Results: In 309 articles, 743,299 antibody tests for 22 NSAbs were performed, including 30,485 tests for 19 NSAbs in healthy controls (HCs). Of these, 26,423 (86.7%) were tested with current standard methods, usually cell-based assays. Prevalence was very low in HCs (mean 0.23%, absent for 9/19 antibodies), and test numbers ranged from 21 to 3,065 per antibody. One study reported >1,000 healthy participants, and the others contained 21–274 samples. CSF samples were virtually not available from HCs. NSAb prevalence was considerably higher (1.5%) in 69,850 disease controls, i.e., patients not initially suspected to have NSAb-mediated diseases. Antibody determination in controls using nonstandard assays (such as ELISA) resulted in 6% positivity. Conclusions: NSAbs are rarely found in healthy participants, particularly with standard detection methods, suggesting high disease specificity and supporting their diagnostic usefulness. Conversely, positive titers in atypical patients might point to the still expanding phenotypic spectrum. Future studies should include more CSF samples, data from HCs, and experimental evidence for antibody pathogenicity. PMID:28761905

  16. Control of treatment size in cavitation-enhanced high-intensity focused ultrasound using radio-frequency echo signals

    NASA Astrophysics Data System (ADS)

    Tomiyasu, Kentaro; Takagi, Ryo; Iwasaki, Ryosuke; Yoshizawa, Shin; Umemura, Shin-ichiro

    2017-07-01

    In high-intensity focused ultrasound (HIFU) treatment, controlling the ultrasound dose at each focal target spot is important because it is a problem that the length of the coagulated region in front of the focal point deviates owing to the differences in absorption in each focal target spot and attenuation in the intervening tissues. In this study, the detected changes in the power spectra of HIFU echoes were used by controlling the HIFU duration in the “trigger HIFU” sequence with the aim to increase coagulation size through the enhancement of the ultrasonic heating by the cavitation induced by the preceding extremely high intensity short “trigger” pulse. The result shows that this method can be used to detect boiling bubbles and the following generated cavitation bubbles at their early stage. By automatically stopping HIFU exposure immediately after detecting the bubbles, overheating was prevented and the deviation of the length of the coagulated region was reduced.

  17. Technical specifications of low-frequency radio identification bedload tracking from field experiments: Differences in antennas, tags and operators

    NASA Astrophysics Data System (ADS)

    Arnaud, F.; Piégay, H.; Vaudor, L.; Bultingaire, L.; Fantino, G.

    2015-06-01

    Low-frequency passive integrated transponders (PIT tags) have been increasingly used for tracking bedload transport in gravel-bed rivers. Prior studies have reported high recovery rates in small streams, while recovery rates remained much lower in large systems, in large part because of the limited reading distance of the tags (< 1 m). Some laboratory tests have identified controlling factors for detection ranges (tag and antenna size, tag orientation, burial, submergence, etc.). Beyond these tests, improving our understanding of PIT tag functioning, using different equipment within different environments, is still needed in order to select the most suitable device for each geomorphic context. We address this knowledge gap with technical specifications for a low-frequency radio identification (RFID) device by working for the first time with real fluvial constraints, i.e., the gravel deposits and the aquatic channel. The three-dimensional detection envelopes of two types of tags and three types of antennas are quantified as well as the effect of practices (interoperator bias, battery power) on the detection. The interoperator variability and the intertag variability can be considered as negligible. The influence of burial in dry and water-saturated sediment and the influence of water immersion are shown to be minor. Finally, we summarize practical implications for RFID bedload tracking through these experiments.

  18. Chromosome aberration analysis in atomic bomb survivors and Thorotrast patients using two- and three-colour chromosome painting of chromosomal subsets.

    PubMed

    Tanaka, K; Popp, S; Fischer, C; Van Kaick, G; Kamada, N; Cremer, T; Cremer, C

    1996-07-01

    Chromosomal translocations in peripheral lymphocytes of three healthy Hiroshima atomic (A)-bomb survivors, as well as three Thorotrast patients and two non-irradiated age-matched control persons from the German Thorotrast study were studied by two- and three-colour fluorescence in situ hybridization (chromosome painting) with various combinations of whole chromosome composite probes, including chromosomes 1, 2, 3, 4, 6, 7, 8, 9 and 12. Translocation frequencies detected by chromosome painting in cells of the A-bomb survivors were compared with results obtained by G-banding. A direct comparison was made, i.e. only those cells with simple translocations or complex aberrations detected by G-banding were taken into consideration which in principle could be detected also with the respective painting combination. The statistical analysis revealed no significant differences from a 1:1 relationship between the frequencies of aberrant cells obtained by both methods. The use of genomic translocation frequencies estimated from subsets of chromosomes for biological dosimetry is discussed in the light of evidence that chromosomes occupy distinct territories and are variably arranged in human lymphocyte nuclei. This territorial organization of interphase chromosomes implies that translocations will be restricted to chromatin located at the periphery of adjacent chromosome territories.

  19. Can poison control data be used for pharmaceutical poisoning surveillance?

    PubMed

    Naun, Christopher A; Olsen, Cody S; Dean, J Michael; Olson, Lenora M; Cook, Lawrence J; Keenan, Heather T

    2011-05-01

    To determine the association between the frequencies of pharmaceutical exposures reported to a poison control center (PCC) and those seen in the emergency department (ED). A statewide population-based retrospective comparison of frequencies of ED pharmaceutical poisonings with frequencies of pharmaceutical exposures reported to a regional PCC. ED poisonings, identified by International Classification of Diseases, Version 9 (ICD-9) codes, were grouped into substance categories. Using a reproducible algorithm facilitated by probabilistic linkage, codes from the PCC classification system were mapped into the same categories. A readily identifiable subset of PCC calls was selected for comparison. Correlations between frequencies of quarterly exposures by substance categories were calculated using Pearson correlation coefficients and partial correlation coefficients with adjustment for seasonality. PCC reported exposures correlated with ED poisonings in nine of 10 categories. Partial correlation coefficients (r(p)) indicated strong associations (r(p)>0.8) for three substance categories that underwent large changes in their incidences (opiates, benzodiazepines, and muscle relaxants). Six substance categories were moderately correlated (r(p)>0.6). One category, salicylates, showed no association. Limitations Imperfect overlap between ICD-9 and PCC codes may have led to miscategorization. Substances without changes in exposure frequency have inadequate variability to detect association using this method. PCC data are able to effectively identify trends in poisonings seen in EDs and may be useful as part of a pharmaceutical poisoning surveillance system. The authors developed an algorithm-driven technique for mapping American Association of Poison Control Centers codes to ICD-9 codes and identified a useful subset of poison control exposures for analysis.

  20. A finite state machine read-out chip for integrated surface acoustic wave sensors

    NASA Astrophysics Data System (ADS)

    Rakshit, Sambarta; Iliadis, Agis A.

    2015-01-01

    A finite state machine based integrated sensor circuit suitable for the read-out module of a monolithically integrated SAW sensor on Si is reported. The primary sensor closed loop consists of a voltage controlled oscillator (VCO), a peak detecting comparator, a finite state machine (FSM), and a monolithically integrated SAW sensor device. The output of the system oscillates within a narrow voltage range that correlates with the SAW pass-band response. The period of oscillation is of the order of the SAW phase delay. We use timing information from the FSM to convert SAW phase delay to an on-chip 10 bit digital output operating on the principle of time to digital conversion (TDC). The control inputs of this digital conversion block are generated by a second finite state machine operating under a divided system clock. The average output varies with changes in SAW center frequency, thus tracking mass sensing events in real time. Based on measured VCO gain of 16 MHz/V our system will convert a 10 kHz SAW frequency shift to a corresponding mean voltage shift of 0.7 mV. A corresponding shift in phase delay is converted to a one or two bit shift in the TDC output code. The system can handle alternate SAW center frequencies and group delays simply by adjusting the VCO control and TDC delay control inputs. Because of frequency to voltage and phase to digital conversion, this topology does not require external frequency counter setups and is uniquely suitable for full monolithic integration of autonomous sensor systems and tags.

  1. Quality Control of Next-generation Sequencing-based In vitro Diagnostic Test for Onco-relevant Mutations Using Multiplex Reference Materials in Plasma.

    PubMed

    Liu, Donglai; Zhou, Haiwei; Shi, Dawei; Shen, Shu; Tian, Yabin; Wang, Lin; Lou, Jiatao; Cong, Rong; Lu, Juan; Zhang, Henghui; Zhao, Meiru; Zhu, Shida; Cao, Zhisheng; Jin, Ruilin; Wang, Yin; Zhang, Xiaoni; Yang, Guohua; Wang, Youchun; Zhang, Chuntao

    2018-01-01

    Background: Widespread clinical implementation of next-generation sequencing (NGS)-based cancer in vitro diagnostic tests (IVDs) highlighted the urgency to establish reference materials which could provide full control of the process from nucleic acid extraction to test report generation. The formalin-fixed, paraffin-embedded (FFPE) tissue and blood plasma containing circulating tumor deoxyribonucleic acid (ctDNA) were mostly used for clinically detecting onco-relevant mutations. Methods: We respectively developed multiplex FFPE and plasma reference materials covering three clinically onco-relevant mutations within the epidermal growth factor receptor ( EGFR ) gene at serial allelic frequencies. All reference materials were quantified and validated via droplet digital polymerase chain reaction (ddPCR), and then were distributed to eight domestic manufacturers for the collaborative evaluation of the performance of several domestic NGS-based cancer IVDs covering four major NGS platforms (NextSeq, HiSeq, Ion Proton and BGISEQ). Results: All expected mutations except one at extremely low allelic frequencies were detected, despite some differences in coefficient of variation (CV) which increased with the decrease of allelic frequency (CVs ranging from 18% to 106%). It was worth noting that the CV value seemed to correlate with a particular mutation as well. The repeatability of determination of different mutations was L858R>T790M>19del. Conclusions: The results indicated our reference materials would be pivotal for quality control of NGS-based cancer IVDs and would guide the further development of reference materials covering more onco-relevant mutations.

  2. [Frequency of CHEK2 gene mutations in patients with breast cancer from the Republic of Bashkortostan].

    PubMed

    2014-01-01

    Several studies have shown, that mutation in CHEK2 gene can increase the risk of different cancers, including breast cancer (BC). Clearly, that character of mutations distribution in the defined regions is depended on genetic structure of the population. We conducted the screening of mutations c.1100delC, c.444 + 1G>A, de15395, p.I157T andIp.R145Win CHEK2 gene in patients with breast cancer (n = 977) and in control group (n = 1069) originating from the Republic of Bashkortostan. The mutation de15395 in CHEK2 gene was detected with frequency of 1,23% (12/977)in woman with BC and 0.09% (1/1069) in controls (OR:13.28, CI 95%: 1.72-102.33, p = 0.003). Mutations c.1100delC and c.444 + 1G>A were found in BC patients and controls with frequencies of 0.4%, 0.4% (4/977) and 0.09% (1/1069), 0.2% (2/1069), respectively. The missense mutation p.I157T in CHEK2 was found as the most common variant in two studied cohorts (approximately 5%), but differences did not achieved statistical significance. We found the ethnic specificity in distribution of truncating mutations, which occurs mainly among the women of Slavic origin. All three mutations were identified in women of Russian and Ukrainian ethnic origin. Mutations c.1100delC and c.444 + 1G>A in CHEK2 gene were not detected in Bashkirs and Tatars, but CHEK2 de15395 mutation was observed in Tatars.

  3. Frequency-agile THz-wave generation and detection system using nonlinear frequency conversion at room temperature.

    PubMed

    Guo, Ruixiang; Ikar'i, Tomofumi; Zhang, Jun; Minamide, Hiroaki; Ito, Hiromasa

    2010-08-02

    A surface-emitting THz parametric oscillator is set up to generate a narrow-linewidth, nanosecond pulsed THz-wave radiation. The THz-wave radiation is coherently detected using the frequency up-conversion in MgO: LiNbO(3) crystal. Fast frequency tuning and automatic achromatic THz-wave detection are achieved through a special optical design, including a variable-angle mirror and 1:1 telescope devices in the pump and THz-wave beams. We demonstrate a frequency-agile THz-wave parametric generation and THz-wave coherent detection system. This system can be used as a frequency-domain THz-wave spectrometer operated at room-temperature, and there are a high possible to develop into a real-time two-dimensional THz spectral imaging system.

  4. Gamma frequency SSVEP components differentiate children with febrile seizures from normal controls.

    PubMed

    Birca, Ala; Carmant, Lionel; Lortie, Anne; Vannasing, Phetsamone; Lassonde, Maryse

    2008-11-01

    Gamma band electroencephalography (EEG) abnormalities have been reported in patients with epilepsy. We aimed to investigate whether patients with febrile seizures (FS) show abnormalities of the gamma frequency steady-state visual evoked potential (SSVEP) components evoked by intermittent photic stimulation (IPS). We analyzed the magnitude and phase alignment of the 50-100 Hz SSVEP components elicited by IPS from 12 FS patients, 5 siblings of FS patients, and 15 control children between 6 and 36 months of age. Patients with FS showed significantly higher SSVEP magnitude and phase alignment values when compared to both the siblings and control groups. Detected abnormalities could either represent the direct consequence of seizures or indicate a preexisting tendency to hypersynchrony in FS patients. Future prospective studies could assess whether SSVEP abnormalities are associated with complex rather than simple FS, or have a prognostic value for the development of epilepsy following FS.

  5. [Association Between SNP rs6007897 of CELSR1 and Acute Ischemic Stroke in Western China Han Population: a Case-control Study].

    PubMed

    Qin, Feng-qin; Yu, Li-hua; Hu, Wen-ting; Guo, Jian; Chen, Ning; Guo, Jiang; Fang, Jing-huan; He, Li

    2015-07-01

    To investigate the relationship between single nucleotide polymorphism (SNP) rs6007897 of CELSR1 and acute ischemic stroke in Western China Han population. All subjects (759 acute ischemic stroke patients and 786 controls) were genotyped using ligation detection reaction (LDR). We analyzed the differences between SNP rs6007897 genotypes and allele frequencies between two groups. Two genotypes (AA, AG) of rs6007897 were found in both stroke and control group. There was no statistically significance between two groups about genotype and allele frequency. After adjusting for risk factors, we found there was no significant association between rs6007897 and ischemic stroke CP = 0.797, odds ratio (OR) = 0.886, 95% confidence interval (CI) = 0.352-2.227). SNP rs6007897 of CELSR1 was not significantly associated with ischemic stroke in Western China Han population.

  6. Feedback control of persistent-current oscillation based on the atomic-clock technique

    NASA Astrophysics Data System (ADS)

    Yu, Deshui; Dumke, Rainer

    2018-05-01

    We propose a scheme of stabilizing the persistent-current Rabi oscillation based on the flux qubit-resonator-atom hybrid structure. The low-Q L C resonator weakly interacts with the flux qubit and maps the persistent-current Rabi oscillation of the flux qubit onto the intraresonator electric field. This oscillating electric field is further coupled to a Rydberg-Rydberg transition of the 87Rb atoms. The Rabi-frequency fluctuation of the flux qubit is deduced from measuring the atomic population via the fluorescence detection and stabilized by feedback controlling the external flux bias. Our numerical simulation indicates that the feedback-control method can efficiently suppress the background fluctuations in the flux qubit, especially in the low-frequency limit. This technique may be extensively applicable to different types of superconducting circuits, paving a way to long-term-coherence superconducting quantum information processing.

  7. Failure detection and identification

    NASA Technical Reports Server (NTRS)

    Massoumnia, Mohammad-Ali; Verghese, George C.; Willsky, Alan S.

    1989-01-01

    Using the geometric concept of an unobservability subspace, a solution is given to the problem of detecting and identifying control system component failures in linear, time-invariant systems. Conditions are developed for the existence of a causal, linear, time-invariant processor that can detect and uniquely identify a component failure, first for the case where components can fail simultaneously, and then for the case where they fail only one at a time. Explicit design algorithms are provided when these conditions are satisfied. In addition to time-domain solvability conditions, frequency-domain interpretations of the results are given, and connections are drawn with results already available in the literature.

  8. A Dual Frequency Carrier Phase Error Difference Checking Algorithm for the GNSS Compass.

    PubMed

    Liu, Shuo; Zhang, Lei; Li, Jian

    2016-11-24

    The performance of the Global Navigation Satellite System (GNSS) compass is related to the quality of carrier phase measurement. How to process the carrier phase error properly is important to improve the GNSS compass accuracy. In this work, we propose a dual frequency carrier phase error difference checking algorithm for the GNSS compass. The algorithm aims at eliminating large carrier phase error in dual frequency double differenced carrier phase measurement according to the error difference between two frequencies. The advantage of the proposed algorithm is that it does not need additional environment information and has a good performance on multiple large errors compared with previous research. The core of the proposed algorithm is removing the geographical distance from the dual frequency carrier phase measurement, then the carrier phase error is separated and detectable. We generate the Double Differenced Geometry-Free (DDGF) measurement according to the characteristic that the different frequency carrier phase measurements contain the same geometrical distance. Then, we propose the DDGF detection to detect the large carrier phase error difference between two frequencies. The theoretical performance of the proposed DDGF detection is analyzed. An open sky test, a manmade multipath test and an urban vehicle test were carried out to evaluate the performance of the proposed algorithm. The result shows that the proposed DDGF detection is able to detect large error in dual frequency carrier phase measurement by checking the error difference between two frequencies. After the DDGF detection, the accuracy of the baseline vector is improved in the GNSS compass.

  9. Frequency and genotype of human parvovirus B19 among Iranian patients infected with HIV.

    PubMed

    Azadmanesh, Kayhan; Mohraz, Minoo; Kazemimanesh, Monireh; Aghakhani, Arezoo; Foroughi, Maryam; Banifazl, Mohammad; Eslamifar, Ali; Ramezani, Amitis

    2015-07-01

    The human parvovirus B19 (B19) usually causes a subclinical infection in immunocompetent individuals. Whereas immunocompromised individuals such as patients infected with HIV are at risk of persistent anemia due to B19 infection. Only few studies have been carried out on distribution and molecular epidemiology of B19 in Iran. We aimed to determine the frequency and genotype of B19 among Iranian patients infected with HIV. We conducted a survey on 99 HIV patients and 64 healthy controls. IgG and IgM antibodies against B19 were detected by ELISA and B19 DNA was assessed by nested PCR. PCR products were subjected to direct sequencing and classified after phylogenetic analysis. The prevalence of B19 immunoglobulin was 11.1% for IgG and 1% for IgM. B19 DNA was detected in 13.1% of cases. The prevalence of B19 IgG, IgM, and DNA in control group was 25%, 1.6%, and 9.4%, respectively. B19 IgG was significantly lower in HIV group than in normal controls. There was no significant difference regarding anemia between cases and controls. All sequenced B19 isolates belonged to genotype 1A with low genetic diversity. Our findings indicated that in the HAART era, the importance of B19 infections in HIV patients may be limited whereas persistent B19 viremia in the circulation of healthy controls raises a potential concern in blood donations. © 2015 Wiley Periodicals, Inc.

  10. Effect of occupational safety measures on micronucleus frequency in semiconductor workers.

    PubMed

    Winker, Robert; Roos, Gerhard; Pilger, Alexander; Rüdiger, Hugo W

    2008-02-01

    To examine whether semiconductor workers exposed to complex mixtures of chemical waste show an increase in genotoxic effects, and, if so, whether occupational safety measures protect these workers. To assess chemical exposure in the workplace, air monitoring of boron trifluoride and boron trichloride was performed and urinary concentrations of fluoride were measured. The cytokinesis-block micronucleus test on isolated lymphocytes was used for the detection of genotoxic effects. Two series of monitoring have been performed in order to assess the effect of implemented protection measures. We found a significantly higher mean frequency of micronuclei in exposed workers than in controls, whereas air monitoring and measurement of urinary fluoride failed to detect chemical exposure of these workers. Twelve years after implementation of protective measures, the mean level of micronuclei in exposed individuals was found to be as low as those from controls. These findings indicate that exposed workers in the semiconductor industry may have an increased risk of genotoxic effects from complex mixtures of chemical waste products. The decline of the mean level of micronuclei in exposed workers down to the base level of controls after implementation of protective measures points to the significance of adequate safety standards to protect against chromosomal damage in semiconductor personnel.

  11. Early Oscillation Detection Technique for Hybrid DC/DC Converters

    NASA Technical Reports Server (NTRS)

    Wang, Bright L.

    2011-01-01

    Oscillation or instability is a situation that must be avoided for reliable hybrid DC/DC converters. A real-time electronics measurement technique was developed to detect catastrophic oscillations at early stages for hybrid DC/DC converters. It is capable of identifying low-level oscillation and determining the degree of the oscillation at a unique frequency for every individual model of the converters without disturbing their normal operations. This technique is specially developed for space-used hybrid DC/DC converters, but it is also suitable for most of commercial and military switching-mode power supplies. This is a weak-electronic-signal detection technique to detect hybrid DC/DC converter oscillation presented as a specific noise signal at power input pins. It is based on principles of feedback control loop oscillation and RF signal modulations, and is realized by using signal power spectral analysis. On the power spectrum, a channel power amplitude at characteristic frequency (CPcf) and a channel power amplitude at switching frequency (CPsw) are chosen as oscillation level indicators. If the converter is stable, the CPcf is a very small pulse and the CPsw is a larger, clear, single pulse. At early stage of oscillation, the CPcf increases to a certain level and the CPsw shows a small pair of sideband pulses around it. If the converter oscillates, the CPcf reaches to a higher level and the CPsw shows more high-level sideband pulses. A comprehensive stability index (CSI) is adopted as a quantitative measure to accurately assign a degree of stability to a specific DC/DC converter. The CSI is a ratio of normal and abnormal power spectral density, and can be calculated using specified and measured CPcf and CPsw data. The novel and unique feature of this technique is the use of power channel amplitudes at characteristic frequency and switching frequency to evaluate stability and identify oscillations at an early stage without interfering with a DC/DC converter s normal operation. This technique eliminates the probing problem of a gain/phase margin method by connecting the power input to a spectral analyzer. Therefore, it is able to evaluate stability for all kinds of hybrid DC/DC converters with or without remote sense pins, and is suitable for real-time and in-circuit testing. This frequency-domain technique is more sensitive to detect oscillation at early stage than the time-domain method using an oscilloscope.

  12. Chronic effects of cannabis use on the auditory mismatch negativity.

    PubMed

    Greenwood, Lisa-Marie; Broyd, Samantha J; Croft, Rodney; Todd, Juanita; Michie, Patricia T; Johnstone, Stuart; Murray, Robin; Solowij, Nadia

    2014-03-15

    Cannabis use is associated with the development of psychotic symptoms and increased risk for schizophrenia. The mismatch negativity (MMN) is a brain event-related potential marker of change detection thought to index glutamatergic N-methyl-D-aspartate receptor-mediated neurotransmission, which is known to be deficient in schizophrenia. This study examined auditory MMN in otherwise healthy chronic cannabis users compared with nonuser control subjects. Forty-two chronic cannabis users and 44 nonuser healthy control subjects completed a multi-feature MMN paradigm, which included duration, frequency, and intensity deviants (deviants 6%; standards 82%). The MMN was compared between users and control subjects as well as between long- and short-term users and age- and gender-matched control subjects. Associations between MMN, cannabis use measures, and symptoms were examined. The MMN amplitude was significantly reduced to frequency but not duration or intensity deviants in overall cannabis users relative to control subjects. Frequency MMN was similarly attenuated in short- and long-term users relative to control subjects. Long-term users also exhibited reduced duration MMN relative to control subjects and short-term users and this was correlated with increased duration of exposure to cannabis and increased psychotic-like experiences during intoxication. In short-term users, a younger age of onset of regular cannabis use and greater frequency of use were associated with greater psychotic-like experiences and symptomatic distress. These results suggest impaired sensory memory that might reflect N-methyl-D-aspartate receptor dysfunction in chronic cannabis users. The pattern of MMN alterations in cannabis users differed from that typically observed in patients with schizophrenia, indicating overlapping but distinct underlying pathology. Copyright © 2014 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  13. Enhanced detection of a low-frequency signal by using broad squeezed light and a bichromatic local oscillator

    NASA Astrophysics Data System (ADS)

    Li, Wei; Jin, Yuanbin; Yu, Xudong; Zhang, Jing

    2017-08-01

    We experimentally study a protocol of using the broadband high-frequency squeezed vacuum to detect the low-frequency signal. In this scheme, the lower sideband field of the squeezed light carries the low-frequency modulation signal, and the two strong coherent light fields are applied as the bichromatic local oscillator in the homodyne detection to measure the quantum entanglement of the upper and lower sideband for the broadband squeezed light. The power of one of the local oscillators for detecting the upper sideband can be adjusted to optimize the conditional variance in the low-frequency regime by subtracting the photocurrent of the upper sideband field of the squeezed light from that of the lower sideband field. By means of the quantum correlation of the upper and lower sideband for the broadband squeezed light, the low-frequency signal beyond the standard quantum limit is measured. This scheme is appropriate for enhancing the sensitivity of the low-frequency signal by the aid of the broad squeezed light, such as gravitational waves detection, and does not need to directly produce the low-frequency squeezing in an optical parametric process.

  14. Multi-dynamic range compressional wave detection using optical-frequency comb

    NASA Astrophysics Data System (ADS)

    Minamikawa, Takeo; Masuoka, Takashi; Oe, Ryo; Nakajima, Yoshiaki; Yamaoka, Yoshihisa; Minoshima, Kaoru; Yasui, Takeshi

    2018-02-01

    Compressional wave detection is useful means for health monitoring of building, detection of abnormal vibration of moving objects, defect evaluation, and biomedical imaging such as echography and photoacoustic imaging. The frequency of the compressional wave is varied from quasi-static to a few tens of megahertz depending on applications. Since the dynamic range of general compressional wave detectors is limited, we need to choose a proper compressional wave detector depending on applications. For the compressional wave detection with wide dynamic range, two or more detectors with different detection ranges is required. However, these detectors with different detection ranges generally has different accuracy and precision, disabling the seamless detection over these detection ranges. In this study, we proposed a compressional wave detector employing optical frequency comb (OFC). The compressional wave was sensed with a part of an OFC cavity, being encoded into OFC. The spectrally encoded OFC was converted to radio-frequency by the frequency link nature of OFC. The compressional wave-encoded radio-frequency can therefore be directly measured with a high-speed photodetector. To enhance the dynamic range of the compressional wave detection, we developed a cavityfeedback-based system and a phase-sensitive detection system, both of which the accuracy and precision are coherently linked to these of the OFC. We provided a proof-of-principle demonstration of the detection of compressional wave from quasi-static to ultrasound wave by using the OFC-based compressional wave sensor. Our proposed approach will serve as a unique and powerful tool for detecting compressional wave versatile applications in the future.

  15. High-accuracy resolver-to-digital conversion via phase locked loop based on PID controller

    NASA Astrophysics Data System (ADS)

    Li, Yaoling; Wu, Zhong

    2018-03-01

    The problem of resolver-to-digital conversion (RDC) is transformed into the problem of angle tracking control, and a phase locked loop (PLL) method based on PID controller is proposed in this paper. This controller comprises a typical PI controller plus an incomplete differential which can avoid the amplification of higher-frequency noise components by filtering the phase detection error with a low-pass filter. Compared with conventional ones, the proposed PLL method makes the converter a system of type III and thus the conversion accuracy can be improved. Experimental results demonstrate the effectiveness of the proposed method.

  16. Characterization of ultrafast devices using novel optical techniques

    NASA Astrophysics Data System (ADS)

    Ali, Md Ershad

    Optical techniques have been extensively used to examine the high frequency performance of a number of devices including High Electron Mobility Transistors (HEMTs), Heterojunction Bipolar Phototransistors (HPTs) and Low Temperature GaAs (LT-GaAs) Photoconductive Switches. To characterize devices, frequency and time domain techniques, namely optical heterodyning and electro-optic sampling, having measurement bandwidths in excess of 200 GHz, were employed. Optical mixing in three-terminal devices has been extended for the first time to submillimeter wave frequencies. Using a new generation of 50-nm gate pseudomorphic InP-based HEMTs, optically mixed signals were detected to 552 GHz with a signal-to-noise ratio of approximately 5 dB. To the best of our knowledge, this is the highest frequency optical mixing obtained in three- terminal devices to date. A novel harmonic three-wave detection scheme was used for the detection of the optically generated signals. The technique involved downconversion of the signal in the device by the second harmonic of a gate-injected millimeter wave local oscillator. Measurements were also conducted up to 212 GHz using direct optical mixing and up to 382 GHz using a fundamental three-wave detection scheme. New interesting features in the bias dependence of the optically mixed signals have been reported. An exciting novel development from this work is the successful integration of near-field optics with optical heterodyning. The technique, called near-field optical heterodyning (NFOH), allows for extremely localized injection of high-frequency stimulus to any arbitrary point of an ultrafast device or circuit. Scanning the point of injection across the sample provides details of the high frequency operation of the device with high spatial resolution. For the implementation of the technique, fiber-optic probes with 100 nm apertures were fabricated. A feedback controlled positioning system was built for accurate placement and scanning of the fiber probe with nanometric precision. The applicability of the NFOH technique was first confirmed by measurements on heterojunction phototransistors at 100 GHz. Later NFOH scans were performed at 63 GHz on two other important devices, HEMTs and LT-GaAs Photoconductive Switches. Spatially resolved response characteristics of these devices revealed interesting details of their operation.

  17. Characteristics and Frequency of Chipping Effects in Near-Contact Gunshot Wounds.

    PubMed

    Amadasi, Alberto; Mazzarelli, Debora; Merli, Daniele; Brandone, Alberto; Cattaneo, Cristina

    2017-05-01

    The presence of "chipping" or "flaking" around the edges of gunshot entry wounds has been described among the characteristics of gunshot wounds in bone. In this study, the real frequency of such a peculiar feature was investigated. The presence of "chipping" was assessed on 22 gunshot wounds fired at a near-contact range on bovine ribs with 9-mm bullets. As controls, five samples were shot with a 3 cm range, and five from 40 cm. In 77% of cases shot at near-contact range, a detachment of small fragments of the upper layers of bone was detected, mainly with a circumferential disposition, whereas this feature was lacking in control samples. The study demonstrated the frequency of "chipping" and that it may probably be due to a combined ballistic effect of impact of the bullet itself and expansion of gases. It may be thus considered indicative of close-range shots. © 2016 American Academy of Forensic Sciences.

  18. Electrodiagnostic applications of somatosensory evoked high-frequency EEG oscillations: Technical considerations.

    PubMed

    Simpson, A J; Cunningham, M O; Baker, M R

    2018-03-01

    High frequency oscillations (HFOs) embedded within the somatosensory evoked potential (SEP) are not routinely recorded/measured as part of standard clinical SEPs. However, HFOs could provide important additional diagnostic/prognostic information in various patient groups in whom SEPs are tested routinely. One area is the management of patients with hypoxic ischaemic encephalopathy (HIE) in the intensive care unit (ICU). However, the sensitivity of standard clinical SEP recording techniques for detecting HFOs is unknown. SEPs were recorded using routine clinical methods in 17 healthy subjects (median nerve stimulation; 0.5 ms pulse width; 5 Hz; maximum 4000 stimuli) in an unshielded laboratory. Bipolar EEG recordings were acquired (gain 50 k; bandpass 3Hz-2 kHz; sampling rate 5 kHz; non-inverting electrode 2 cm anterior to C3/C4; inverting electrode 2 cm posterior to C3/C4). Data analysis was performed in MATLAB. SEP-HFOs were detected in 65% of controls using standard clinical recording techniques. In 3 controls without significant HFOs, experiments were repeated using a linear electrode array with higher spatial sampling frequency. SEP-HFOs were observed in all 3 subjects. Currently standard clinical methods of recording SEPs are not sufficiently sensitive to permit the inclusion of SEP-HFOs in routine clinical diagnostic/prognostic assessments. Whilst an increase in the number/density of EEG electrodes should improve the sensitivity for detecting SEP-HFOs, this requires confirmation. By improving and standardising clinical SEP recording protocols to permit the acquisition/analysis of SEP-HFOs, it should be possible to gain important insights into the pathophysiology of neurological disorders and refine the management of conditions such as HIE. Copyright © 2018. Published by Elsevier Inc.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowla, F

    Long-range, ultra-wideband (UWB), passive radio frequency (RF) tags are key components in Radio Frequency IDentification (RFID) system that will revolutionize inventory control and tracking applications. Unlike conventional, battery-operated (active) RFID tags, LLNL's small UWB tags, called 'UTag', operate at long range (up to 20 meters) in harsh, cluttered environments. Because they are battery-less (that is, passive), they have practically infinite lifetimes without human intervention, and they are lower in cost to manufacture and maintain than active RFID tags. These robust, energy-efficient passive tags are remotely powered by UWB radio signals, which are much more difficult to detect, intercept, and jammore » than conventional narrowband frequencies. The features of long range, battery-less, and low cost give UTag significant advantage over other existing RFID tags.« less

  20. Performance analysis of ultrasono-therapy transducer with contact detection.

    PubMed

    Moreno, Eduardo; González, Gilberto; Leija, Lorenzo; Rodríguez, Orlando; Castillo, Martha; Fuentes, Martín

    2003-06-01

    The performance of ultrasono-therapy transducer with contact detection by using the impedance phase change is described. Usually a therapy transducer is designed with a lambda/2 frontal plate glued to a PZT-4 piezoceramic. This plate ensures a good mechanical protection of the piezoceramic with a corresponding high-transmission energy. Normally this transducer is operated at the minimum at the frequency of the impedance module of its input electric impedance, but this operation point is affected by the shift caused by the expected temperature increase. This shift could be higher than the narrow bandwidth presented. As a result we obtain a decrease in the power level for medical treatment. Usually it is designed electronic drivers with automatic control that follow the frequency change, but the relatively narrow bandwidth introduces difficulty in the design. Another frequency operation point is presented here and analyzed using the criteria of the maximum of the impedance phase with a wider bandwidth than in the previous case. Simulation with mechanical losses are presented with experimental results that show the convenience of this criteria for practical application.

  1. Efferent control of temporal response properties of the Limulus lateral eye

    PubMed Central

    1990-01-01

    The sensitivity of the Limulus lateral eye exhibits a pronounced circadian rhythm. At night a circadian oscillator in the brain activates efferent fibers in the optic nerve, inducing multiple changes in the physiological and anatomical characteristics of retinal cells. These changes increase the sensitivity of the retina by about five orders of magnitude. We investigated whether this increase in retinal sensitivity is accompanied by changes in the ability of the retina to process temporal information. We measured the frequency transfer characteristic (FTC) of single receptors (ommatidia) by recording the response of their optic nerve fibers to sinusoidally modulated light. We first measured the FTC in the less sensitive daytime state and then after converting the retina to the more sensitive nighttime state by electrical stimulation of the efferent fibers. The activation of these fibers shifted the peak of the FTC to lower frequencies and reduced the slope of the low-frequency limb. These changes reduce the eye's ability to detect rapid changes in light intensity but enhance its ability to detect dim flashes of light. Apparently Limulus sacrifices temporal resolution for increased visual sensitivity at night. PMID:2307958

  2. Sensitivity Limits of Rydberg Atom-Based Radio Frequency Electric Field Sensing

    NASA Astrophysics Data System (ADS)

    Jahangiri, Akbar J.; Kumar, Santosh; Kuebler, Harald; Fan, Haoquan; Shaffer, James P.

    2017-04-01

    We present progress on Rydberg atom-based RF electric field sensing using Rydberg state electromagnetically induced transparency (EIT) in room temperature atomic vapor cells. In recent experiments on homodyne detection with a Mach-Zehnder interferometer and frequency modulation spectroscopy with active control of residual amplitude modulation we determined that photon shot noise on the probe laser detector limits the sensitivity. Another factor that limits the accuracy is residual Doppler broadening due to the wave-vector mismatch between the coupling and the probe lasers. The sensor as limited by project noise can be orders of magnitude better. A multi-photon scheme is presented that can eliminate the residual Doppler effect by matching the wave-vectors of three lasers and reduce the photon shot noise limit by correctly choosing the Rabi frequencies of the first two steps of the EIT scheme. Using density matrix calculations, we predict that the three-photon approach can improve the detection sensitivity to below 200 nV cm-1 Hz- 1 / 2 and expand the Autler-Townes regime which improves the accuracy. This work is supported by DARPA and the NRO.

  3. Differential neural responses to acupuncture revealed by MEG using wavelet-based time-frequency analysis: a pilot study.

    PubMed

    You, Youbo; Bai, Lijun; Dai, Ruwei; Xue, Ting; Zhong, Chongguang; Feng, Yuanyuan; Wang, Hu; Liu, Zhenyu; Tian, Jie

    2011-01-01

    Acupoint specificity, lying at the core of the Traditional Chinese Medicine, still faces many controversies. As previous neuroimaging studies on acupuncture mainly adopted relatively low time-resolution functional magnetic resonance imaging (fMRI) technology and inappropriate block-designed experimental paradigm due to sustained effect, in the current study, we employed a single block-designed paradigm together with high temporal-resolution magnetoencephalography (MEG) technology. We applied time-frequency analysis based upon Morlet wavelet transforming approach to detect differential oscillatory brain dynamics induced by acupuncture at Stomach Meridian 36 (ST36) using a nearby nonacupoint (NAP) as control condition. We observed that frequency power changes were mainly restricted to delta band for both ST36 group and NAP group. Consistently increased delta band power in contralateral temporal regions and decreased power in the counterparts of ipsilateral hemisphere were detected following stimulation at ST36 on the right leg. Compared with ST36, no significant delta ranges were found in temporal regions in NAP group, illustrating different oscillatory brain patterns. Our results may provide additional evidence to support the specificity of acupuncture modulation effects.

  4. Effects of a prior stretching of the plantarflexor muscles on the capacity to control upright stance maintenance in healthy adults.

    PubMed

    Rougier, Patrice; Burdet, Cyril; Genthon, Nicolas

    2006-10-01

    To assess whether prior stretching of a muscle can induce improved postural control, 15 healthy adults stood still upright with their eyes closed before and after a series of bilateral stretches of the triceps surae muscles. The analysis focused on the center of pressure (CP) and the vertical projection of the center of gravity (CGv) trajectories and their difference (CP - CGv). The prolonged stretching induced a forward shift of the mean position of the CGv. The frequency analysis showed a constancy of the amplitudes of both basic movements whereas an increased mean power frequency was seen for the CP - CGv movements. A fractional Brownian motion modeling of the trajectories indicates shortest time intervals and lower covered distances by the CGv before a change in its control occurs along the antero-posterior axis. This reorganization is thought to be a result of improved body movement detection, which allows postural control over the longest time intervals to be triggered more rapidly.

  5. Blastocystosis in patients with gastrointestinal symptoms: a case–control study

    PubMed Central

    2012-01-01

    Background Blastocystosis is a frequent bowel disease. We planned to to evaluate the prevalence of Blastocystis spp. in patients who applied to the same internal medicine-gastroenterology clinic with or without gastrointestinal complaints to reveal the association of this parasite with diagnosed IBS and IBD. Methods A total of 2334 patients with gastrointestinal symptoms composed the study group, which included 335 patients with diagnosed inflammatory bowel disease and 877 with irritable bowel syndrome. Patients without any gastrointestinal symptoms or disease (n = 192) composed the control group. Parasite presence was investigated by applying native-Lugol and formol ethyl acetate concentration to stool specimens, and trichrome staining method in suspicious cases. Results Blastocystis spp. was detected in 134 patients (5.74%) in the study group and 6 (3.12%) in the control group (p = 0.128). In the study group, Blastocystis spp. was detected at frequencies of 8.7% in ulcerative colitis (24/276), 6.78% in Crohn’s disease (4/59), 5.82% in irritable bowel syndrome (51/877), and 4.9% in the remaining patients with gastrointestinal symptoms (55/1122). Blastocystis spp. was detected at a statistically significant ratio in the inflammatory bowel disease (odds ratio [OR] = 2.824; 95% confidence interval [CI]: 1.149-6.944; p = 0.019) and ulcerative colitis (OR = 2.952; 95% CI: 1.183-7.367; p = 0.016) patients within this group compared to controls. There were no statistically significant differences between the control group and Crohn’s disease or irritable bowel syndrome patients in terms Blastocystis spp. frequency (p = 0.251, p = 0.133). Conclusions Blastocystosis was more frequent in patients with inflammatory bowel disease, especially those with ulcerative colitis. Although symptomatic irritable bowel syndrome and Crohn’s disease patients had higher rates of Blastocystis spp. infection, the differences were not significant when compared to controls. PMID:22963003

  6. Blastocystosis in patients with gastrointestinal symptoms: a case-control study.

    PubMed

    Cekin, Ayhan Hilmi; Cekin, Yesim; Adakan, Yesim; Tasdemir, Ezel; Koclar, Fatma Gulsun; Yolcular, Basak Oguz

    2012-09-10

    Blastocystosis is a frequent bowel disease. We planned to to evaluate the prevalence of Blastocystis spp. in patients who applied to the same internal medicine-gastroenterology clinic with or without gastrointestinal complaints to reveal the association of this parasite with diagnosed IBS and IBD. A total of 2334 patients with gastrointestinal symptoms composed the study group, which included 335 patients with diagnosed inflammatory bowel disease and 877 with irritable bowel syndrome. Patients without any gastrointestinal symptoms or disease (n = 192) composed the control group. Parasite presence was investigated by applying native-Lugol and formol ethyl acetate concentration to stool specimens, and trichrome staining method in suspicious cases. Blastocystis spp. was detected in 134 patients (5.74%) in the study group and 6 (3.12%) in the control group (p = 0.128). In the study group, Blastocystis spp. was detected at frequencies of 8.7% in ulcerative colitis (24/276), 6.78% in Crohn's disease (4/59), 5.82% in irritable bowel syndrome (51/877), and 4.9% in the remaining patients with gastrointestinal symptoms (55/1122). Blastocystis spp. was detected at a statistically significant ratio in the inflammatory bowel disease (odds ratio [OR] = 2.824; 95% confidence interval [CI]: 1.149-6.944; p = 0.019) and ulcerative colitis (OR = 2.952; 95% CI: 1.183-7.367; p = 0.016) patients within this group compared to controls. There were no statistically significant differences between the control group and Crohn's disease or irritable bowel syndrome patients in terms Blastocystis spp. frequency (p = 0.251, p = 0.133). Blastocystosis was more frequent in patients with inflammatory bowel disease, especially those with ulcerative colitis. Although symptomatic irritable bowel syndrome and Crohn's disease patients had higher rates of Blastocystis spp. infection, the differences were not significant when compared to controls.

  7. Label-free in-flow detection of single DNA molecules using glass nanopipettes.

    PubMed

    Gong, Xiuqing; Patil, Amol V; Ivanov, Aleksandar P; Kong, Qingyuan; Gibb, Thomas; Dogan, Fatma; deMello, Andrew J; Edel, Joshua B

    2014-01-07

    With the view of enhancing the functionality of label-free single molecule nanopore-based detection, we have designed and developed a highly robust, mechanically stable, integrated nanopipette-microfluidic device which combines the recognized advantages of microfluidic systems and the unique properties/advantages of nanopipettes. Unlike more typical planar solid-state nanopores, which have inherent geometrical constraints, nanopipettes can be easily positioned at any point within a microfluidic channel. This is highly advantageous, especially when taking into account fluid flow properties. We show that we are able to detect and discriminate between DNA molecules of varying lengths when motivated through a microfluidic channel, upon the application of appropriate voltage bias across the nanopipette. The effects of applied voltage and volumetric flow rates have been studied to ascertain translocation event frequency and capture rate. Additionally, by exploiting the advantages associated with microfluidic systems (such as flow control and concomitant control over analyte concentration/presence), we show that the technology offers a new opportunity for single molecule detection and recognition in microfluidic devices.

  8. Millimeter wave imaging for concealed weapon detection and surveillance at up to 220 GHz

    NASA Astrophysics Data System (ADS)

    Stanko, S.; Nötel, D.; Huck, J.; Wirtz, S.; Klöppel, F.; Essen, H.

    2008-04-01

    Sensors used for security purposes have to cover the non-invasive control of men and direct surroundings of buildings and camps to detect weapons, explosives and chemical or biological threat material. Those sensors have to cope with different environmental conditions. Ideally, the control of people has to be done at a longer distance as standoff detection. The work described in this paper concentrates on passive radiometric sensors at 0.1 and 0.2 THz which are able to detect non-metallic objects like ceramic knifes. Also the identification of objects like mobile phones or PDAs will be shown. Additionally, standoff surveillance is possible, which is of high importance with regard to suicide bombers. The presentation will include images at both mentioned frequencies comparing the efficiency in terms of range and resolution. In addition, the concept of the sensor design showing a Dicke-type 220GHz radiometer using new LNAs and the results along with image enhancement methods are shown. 2.1 Main principle

  9. The present situation and forecasts of semiconductor elements performance within the microwave range, 1970-1985

    NASA Technical Reports Server (NTRS)

    Peterson, B.

    1978-01-01

    The present situation and possible developments over the period 1970-1985 for active semiconductor elements in the microwave range are outlined. After a short historical survey of FT techniques, the following are discussed: Generation, power amplification, amplification of small signals, frequency conversion, detection, electronic signal control and integrated microwave circuits.

  10. 40 CFR 65.107 - Standards: Pumps in light liquid service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... frequency of drips and to the sensor that indicates failure of the seal system, the barrier fluid system, or... or fuel gas system or connected by a closed vent system to a control device that complies with the... equipped with a sensor that will detect failure of the seal system, the barrier fluid system, or both. (v...

  11. 40 CFR 63.1026 - Pumps in light liquid service standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... presence and frequency of drips and to the sensor that indicates failure of the seal system, the barrier... or fuel gas system or connected by a closed-vent system to a control device that complies with the.... (iv) Each barrier fluid system is equipped with a sensor that will detect failure of the seal system...

  12. Polarization feedback laser stabilization

    DOEpatents

    Esherick, Peter; Owyoung, Adelbert

    1988-01-01

    A system for locking two Nd:YAG laser oscillators includes an optical path for feeding the output of one laser into the other with different polarizations. Elliptical polarization is incorporated into the optical path so that the change in polarization that occurs when the frequencies coincide may be detected to provide a feedback signal to control one laser relative to the other.

  13. Acoustic-Emission Weld-Penetration Monitor

    NASA Technical Reports Server (NTRS)

    Maram, J.; Collins, J.

    1986-01-01

    Weld penetration monitored by detection of high-frequency acoustic emissions produced by advancing weld pool as it melts and solidifies in workpiece. Acoustic emission from TIG butt weld measured with 300-kHz resonant transducer. Rise in emission level coincides with cessation of weld penetration due to sudden reduction in welding current. Such monitoring applied to control of automated and robotic welders.

  14. Validation of Serum Markers for the Early Detection of Hepatocellular Carcinoma — EDRN Public Portal

    Cancer.gov

    Using the guidelines for cancer biomarker validation suggested by Pepe et al. (23), we propose to perform a Phase 2 study of DCP for the detection of early stage HCC. In this proposal, we plan to perform a larger case-control study to compare the sensitivity and specificity of DCP and AFP alone and in combination in differentiating patients with all stages of HCC and more importantly those with early HCC from patients with cirrhosis. We plan to enroll consecutive patients with HCC seen at 7 centers in the United States. Controls are frequency matched to cases (all center combined) using the following criteria: age (±10 years), gender (+10%) and etiology of liver disease (viral vs non-viral (+5%). Within each participating institution, there will be an equal number (+20%) of cases and controls.

  15. A Preliminary Engineering Design of Intravascular Dual-Frequency Transducers for Contrast-Enhanced Acoustic Angiography and Molecular Imaging

    PubMed Central

    Ma, Jianguo; Martin, K. Heath; Dayton, Paul A.; Jiang, Xiaoning

    2014-01-01

    Current intravascular ultrasound (IVUS) probes are not optimized for contrast detection because of their design for high-frequency fundamental-mode imaging. However, data from transcutaneous contrast imaging suggests the possibility of utilizing contrast ultrasound for molecular imaging or vasa vasorum assessment to further elucidate atherosclerotic plaque deposition. This paper presents the design, fabrication, and characterization of a small-aperture (0.6 × 3 mm) IVUS probe optimized for high-frequency contrast imaging. The design utilizes a dual-frequency (6.5 MHz/30 MHz) transducer arrangement for exciting microbubbles at low frequencies (near their resonance) and detecting their broadband harmonics at high frequencies, minimizing detected tissue backscatter. The prototype probe is able to generate nonlinear microbubble response with more than 1.2 MPa of rarefractional pressure (mechanical index: 0.48) at 6.5 MHz, and is also able to detect microbubble response with a broadband receiving element (center frequency: 30 MHz, −6-dB fractional bandwidth: 58.6%). Nonlinear super-harmonics from microbubbles flowing through a 200-μm-diameter micro-tube were clearly detected with a signal-to-noise ratio higher than 12 dB. Preliminary phantom imaging at the fundamental frequency (30 MHz) and dual-frequency super-harmonic imaging results suggest the promise of small aperture, dual-frequency IVUS transducers for contrast-enhanced IVUS imaging. PMID:24801226

  16. Effect of radar frequency on the detection of shaped (low RCS) targets

    NASA Astrophysics Data System (ADS)

    Moraitis, D.; Alland, S.

    The use of shaping to reduce the radar cross-section (RCS) of aircraft and missiles can result in the RCS varying significantly with radar operating frequency. This RCS sensitivity to frequency should be considered when selecting radar frequency and should be accounted for when evaluating radar performance. A detection range increase for shaped (low RCS) targets of a factor of two or greater can be realized for lower frequency radar (e.g., UHF-Band or L-Band) when compared to higher frequency radar (C-Band or X-Band). For low flying (sea skimming) targets, the RCS variation with frequency for shaped (low RCS) targets neutralizes the advantage that higher radar frequencies realize in multipath propagation resulting in approximately the same detection range across the radar bands from UHF to X-Band.

  17. Single- and multi-frequency detection of surface displacements via scanning probe microscopy.

    PubMed

    Romanyuk, Konstantin; Luchkin, Sergey Yu; Ivanov, Maxim; Kalinin, Arseny; Kholkin, Andrei L

    2015-02-01

    Piezoresponse force microscopy (PFM) provides a novel opportunity to detect picometer-level displacements induced by an electric field applied through a conducting tip of an atomic force microscope (AFM). Recently, it was discovered that superb vertical sensitivity provided by PFM is high enough to monitor electric-field-induced ionic displacements in solids, the technique being referred to as electrochemical strain microscopy (ESM). ESM has been implemented only in multi-frequency detection modes such as dual AC resonance tracking (DART) and band excitation, where the response is recorded within a finite frequency range, typically around the first contact resonance. In this paper, we analyze and compare signal-to-noise ratios of the conventional single-frequency method with multi-frequency regimes of measuring surface displacements. Single-frequency detection ESM is demonstrated using a commercial AFM.

  18. Close-loop Dynamic Stall Control on a Pitching Airfoil

    NASA Astrophysics Data System (ADS)

    Giles, Ian; Corke, Thomas

    2017-11-01

    A closed-loop control scheme utilizing a plasma actuator to control dynamic stall is presented. The plasma actuator is located at the leading-edge of a pitching airfoil. It initially pulses at an unsteady frequency that perturbs the boundary layer flow over the suction surface of the airfoil. As the airfoil approaches and enters stall, the amplification of the unsteady disturbance is detected by an onboard pressure sensor also located near the leading edge. Once detected, the actuator is switched to a higher voltage control state that in static airfoil experiments would reattach the flow. The threshold level of the detection is a parameter in the control scheme. Three stall regimes were examined: light, medium, and deep stall, that were defined by their stall penetration angles. The results showed that in general, the closed-loop control scheme was effective at controlling dynamic stall. The cycle-integrated lift improved in all cases, and increased by as much as 15% at the lowest stall penetration angle. As important, the cycle-integrated aerodynamic damping coefficient also increased in all cases, and was made to be positive at the light stall regime where it traditionally is negative. The latter is important in applications where negative damping can lead to stall flutter.

  19. Development of a long-gauge vibration sensor

    NASA Astrophysics Data System (ADS)

    Kung, Peter; Comanici, Maria I.; Li, Qian; Zhang, Yiwei

    2014-11-01

    Recently, we found that by terminating a long length of fiber of up to 1 km with an in-fiber cavity structure, the entire structure can detect vibrations over a frequency range from 5 Hz to 100 Hz. We want to determine whether the structure (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to the maintenance cost. Similarly, it will help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that will require the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Then, at even higher frequencies, the structure can be useful to detect acoustic vibrations (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large reenforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed long-gauge vibration sensor depends on packaging.

  20. Search for HRV-parameters that detect a sympathetic shift in heart failure patients on β-blocker treatment.

    PubMed

    Zhang, Yanru; de Peuter, Olav R; Kamphuisen, Pieter W; Karemaker, John M

    2013-01-01

    A sympathetic shift in heart rate variability (HRV) from high to lower frequencies may be an early signal of deterioration in a monitored patient. Most chronic heart failure (CHF) patients receive β-blockers. This tends to obscure HRV observation by increasing the fast variations. We tested which HRV parameters would still detect the change into a sympathetic state. β-blocker (Carvedilol®) treated CHF patients underwent a protocol of 10 min supine rest, followed by 10 min active standing. CHF patients (NYHA Class II-IV) n = 15, 10m/5f, mean age 58.4 years (47-72); healthy controls n = 29, 18m/11f, mean age 62.9 years (49-78). Interbeat intervals (IBI) were extracted from the finger blood pressure wave (Nexfin®). Both linear and non-linear HRV analyses were applied that (1) might be able to differentiate patients from healthy controls under resting conditions and (2) detect the change into a sympathetic state in the present short recordings. Linear: mean-IBI, SD-IBI, root mean square of successive differences (rMSSD), pIBI-50 (the proportion of intervals that differs by more than 50 ms from the previous), LF, HF, and LF/HF ratio. Non-linear: Sample entropy (SampEn), Multiscale entropy (MSE), and derived: Multiscale variance (MSV) and Multiscale rMSSD (MSD). In the supine resting situation patients differed from controls by having higher HF and, consequently, lower LF/HF. In addition their longer range (τ = 6-10) MSE was lower as well. The sympathetic shift was, in controls, detected by mean-IBI, rMSSD, pIBI-50, and LF/HF, all going down; in CHF by mean-IBI, rMSSD, pIBI-50, and MSD (τ = 6-10) going down. MSD6-10 introduced here works as a band-pass filter favoring frequencies from 0.02 to 0.1 Hz. In β-blocker treated CHF patients, traditional time domain analysis (mean-IBI, rMSSD, pIBI-50) and MSD6-10 provide the most useful information to detect a condition change.

  1. Study of Radio sources and interferences detected by MEXART

    NASA Astrophysics Data System (ADS)

    Villanueva Hernandez, P.; Gonzalez Esparza, J. A.; Carrillo, A.; Andrade, E.; Jeyacumar, S.; Kurtz, S.

    2007-05-01

    The Mexican Array Radio Telescope (MEXART) is a radio telescope that will perform studies of solar wind disturbances using the Interplanetary Scintillation (IPS) technique. The radiotelescope is its final calibration stage, and in this work we report two testings: the interference signals detected around the operation frequency, and the transit of the main radio sources detected by individual lines of 64 dipoles. These radio sources are: Sun, Casiopea, Crab nebula, Cygnus and Virgo. These testings allow us to know the response of the array elements in order to calibrate them. The final operation of the MEXART requires that the signal detected and transmitted by each East-West line of 64 dipoles arrives at the butler matrix (control room) with the same phase and amplitude.

  2. Dynamic ultrasonic contact detection using acoustic emissions.

    PubMed

    Turner, S L; Rabani, A; Axinte, D A; King, C W

    2014-03-01

    For a non-contact ultrasonic material removal process, the control of the standoff position can be crucial to process performance; particularly where the requirement is for a standoff of the order of <20 μm. The standoff distance relative to the surface to be machined can be set by first contacting the ultrasonic tool tip with the surface and then withdrawing the tool to the required position. Determination of this contact point in a dynamic system at ultrasonic frequencies (>20 kHz) is achieved by force measurement or by detection of acoustic emissions (AE). However, where detection of distance from a surface must be determined without contact taking place, an alternative method must be sought. In this paper, the effect of distance from contact of an ultrasonic tool is measured by detection of AE through the workpiece. At the point of contact, the amplitude of the signal at the fundamental frequency increases significantly, but the strength of the 2nd and 3rd harmonic signals increases more markedly. Closer examination of these harmonics shows that an increase in their intensities can be observed in the 10 μm prior to contact, providing a mechanism to detect near contact (<10 μm) without the need to first contact the surface in order to set a standoff. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. A DNA pooling based system to detect Escherichia coli virulence factors in fecal and wastewater samples

    PubMed Central

    Luz María Chacón, J; Lizeth Taylor, C; Carmen Valiente, A; Irene Alvarado, P; Ximena Cortés, B

    2012-01-01

    The availability of a useful tool for simple and timely detection of the most important virulent varieties of Escherichia coli is indispensable. To this end, bacterial DNA pools which had previously been categorized were obtained from isolated colonies as well as selected in terms of utilized phenotype; the pools were assessed by two PCR Multiplex for the detection of virulent E. coli eaeA, bfpA, stx1, stx2, ipaH, ST, LT, and aatA genes, with the 16S gene used as DNA control. The system was validated with 66 fecal samples and 44 wastewater samples. At least one positive isolate was detected by a virulent gene among the 20 that were screened. The analysis of fecal samples from children younger than 6 years of age detected frequencies of 25% LT positive strains, 8.3% eae, 8.3% bfpA, 16.7% ipaH, as well as 12.5 % aatA and ST. On the other hand, wastewater samples revealed frequencies of 25.7% eaeA positive, 30.3% stx1, 15.1% LT and 19.7% aatA. This study is an initial step toward carrying out epidemiological field research that will reveal the presence of these bacterial varieties. PMID:24031959

  4. Spatial gradient for unique-feature detection in patients with unilateral neglect: evidence from auditory and visual search.

    PubMed

    Eramudugolla, Ranmalee; Mattingley, Jason B

    2008-01-01

    Patients with unilateral spatial neglect following right hemisphere damage are impaired in detecting contralesional targets in both visual and haptic search tasks, and often show a graded improvement in detection performance for more ipsilesional spatial locations. In audition, multiple simultaneous sounds are most effectively perceived if they are distributed along the frequency dimension. Thus, attention to spectro-temporal features alone can allow detection of a target sound amongst multiple simultaneous distracter sounds, regardless of whether these sounds are spatially separated. Spatial bias in attention associated with neglect should not affect auditory search based on spectro-temporal features of a sound target. We report that a right brain damaged patient with neglect demonstrated a significant gradient favouring the ipsilesional side on a visual search task as well as an auditory search task in which the target was a frequency modulated tone amongst steady distractor tones. No such asymmetry was apparent in the auditory search performance of a control patient with a right hemisphere lesion but no neglect. The results suggest that the spatial bias in attention exhibited by neglect patients affects stimulus processing even when spatial information is irrelevant to the task.

  5. Gait Event Detection in Real-World Environment for Long-Term Applications: Incorporating Domain Knowledge Into Time-Frequency Analysis.

    PubMed

    Khandelwal, Siddhartha; Wickstrom, Nicholas

    2016-12-01

    Detecting gait events is the key to many gait analysis applications that would benefit from continuous monitoring or long-term analysis. Most gait event detection algorithms using wearable sensors that offer a potential for use in daily living have been developed from data collected in controlled indoor experiments. However, for real-word applications, it is essential that the analysis is carried out in humans' natural environment; that involves different gait speeds, changing walking terrains, varying surface inclinations and regular turns among other factors. Existing domain knowledge in the form of principles or underlying fundamental gait relationships can be utilized to drive and support the data analysis in order to develop robust algorithms that can tackle real-world challenges in gait analysis. This paper presents a novel approach that exhibits how domain knowledge about human gait can be incorporated into time-frequency analysis to detect gait events from long-term accelerometer signals. The accuracy and robustness of the proposed algorithm are validated by experiments done in indoor and outdoor environments with approximately 93 600 gait events in total. The proposed algorithm exhibits consistently high performance scores across all datasets in both, indoor and outdoor environments.

  6. Sensitivity to Regional Earthquake Triggering and Magnitude-Frequency Characteristics of Microseismicity Detected via Matched-Filter Analysis, Central Southern Alps, New Zealand

    NASA Astrophysics Data System (ADS)

    Boese, C. M.; Townend, J.; Chamberlain, C. J.; Warren-Smith, E.

    2016-12-01

    Microseismicity recorded since 2008 by the Southern Alps Microseismicity Borehole Array (SAMBA) and other predominantly short-period seismic networks deployed in the central Southern Alps, New Zealand, reveals distinctive patterns of triggering in response to regional seismicity (magnitudes larger than 5, epicentral distances of 100-500 km). Using matched-filter detection methods implemented in the EQcorrscan package (Chamberlain et al., in prep.), we analyze microseismicity occurring in several geographically distinct swarms in order to examine the responses of specific microearthquake sources to earthquakes of different sizes occurring at different distances and azimuths. The swarms exhibit complex responses to regional seismicity which reveal that microearthquake triggering in these cases involves a combination of extrinsic factors (related to the dynamic stresses produced by the regional earthquake) and intrinsic factors (controlled by the local state of stress and possibly by hydrogeological processes). We find also that the microearthquakes detected by individual templates have Gutenberg-Richter magnitude-frequency characteristics. Since the detected events, by design, have very similar hypocentres and focal mechanisms, the observed scaling pertains to a restricted set of fault planes.

  7. Data mining neocortical high-frequency oscillations in epilepsy and controls

    PubMed Central

    Stead, Matt; Krieger, Abba; Stacey, William; Maus, Douglas; Marsh, Eric; Viventi, Jonathan; Lee, Kendall H.; Marsh, Richard; Litt, Brian; Worrell, Gregory A.

    2011-01-01

    Transient high-frequency (100–500 Hz) oscillations of the local field potential have been studied extensively in human mesial temporal lobe. Previous studies report that both ripple (100–250 Hz) and fast ripple (250–500 Hz) oscillations are increased in the seizure-onset zone of patients with mesial temporal lobe epilepsy. Comparatively little is known, however, about their spatial distribution with respect to seizure-onset zone in neocortical epilepsy, or their prevalence in normal brain. We present a quantitative analysis of high-frequency oscillations and their rates of occurrence in a group of nine patients with neocortical epilepsy and two control patients with no history of seizures. Oscillations were automatically detected and classified using an unsupervised approach in a data set of unprecedented volume in epilepsy research, over 12 terabytes of continuous long-term micro- and macro-electrode intracranial recordings, without human preprocessing, enabling selection-bias-free estimates of oscillation rates. There are three main results: (i) a cluster of ripple frequency oscillations with median spectral centroid = 137 Hz is increased in the seizure-onset zone more frequently than a cluster of fast ripple frequency oscillations (median spectral centroid = 305 Hz); (ii) we found no difference in the rates of high frequency oscillations in control neocortex and the non-seizure-onset zone neocortex of patients with epilepsy, despite the possibility of different underlying mechanisms of generation; and (iii) while previous studies have demonstrated that oscillations recorded by parenchyma-penetrating micro-electrodes have higher peak 100–500 Hz frequencies than penetrating macro-electrodes, this was not found for the epipial electrodes used here to record from the neocortical surface. We conclude that the relative rate of ripple frequency oscillations is a potential biomarker for epileptic neocortex, but that larger prospective studies correlating high-frequency oscillations rates with seizure-onset zone, resected tissue and surgical outcome are required to determine the true predictive value. PMID:21903727

  8. Data mining neocortical high-frequency oscillations in epilepsy and controls.

    PubMed

    Blanco, Justin A; Stead, Matt; Krieger, Abba; Stacey, William; Maus, Douglas; Marsh, Eric; Viventi, Jonathan; Lee, Kendall H; Marsh, Richard; Litt, Brian; Worrell, Gregory A

    2011-10-01

    Transient high-frequency (100-500 Hz) oscillations of the local field potential have been studied extensively in human mesial temporal lobe. Previous studies report that both ripple (100-250 Hz) and fast ripple (250-500 Hz) oscillations are increased in the seizure-onset zone of patients with mesial temporal lobe epilepsy. Comparatively little is known, however, about their spatial distribution with respect to seizure-onset zone in neocortical epilepsy, or their prevalence in normal brain. We present a quantitative analysis of high-frequency oscillations and their rates of occurrence in a group of nine patients with neocortical epilepsy and two control patients with no history of seizures. Oscillations were automatically detected and classified using an unsupervised approach in a data set of unprecedented volume in epilepsy research, over 12 terabytes of continuous long-term micro- and macro-electrode intracranial recordings, without human preprocessing, enabling selection-bias-free estimates of oscillation rates. There are three main results: (i) a cluster of ripple frequency oscillations with median spectral centroid = 137 Hz is increased in the seizure-onset zone more frequently than a cluster of fast ripple frequency oscillations (median spectral centroid = 305 Hz); (ii) we found no difference in the rates of high frequency oscillations in control neocortex and the non-seizure-onset zone neocortex of patients with epilepsy, despite the possibility of different underlying mechanisms of generation; and (iii) while previous studies have demonstrated that oscillations recorded by parenchyma-penetrating micro-electrodes have higher peak 100-500 Hz frequencies than penetrating macro-electrodes, this was not found for the epipial electrodes used here to record from the neocortical surface. We conclude that the relative rate of ripple frequency oscillations is a potential biomarker for epileptic neocortex, but that larger prospective studies correlating high-frequency oscillations rates with seizure-onset zone, resected tissue and surgical outcome are required to determine the true predictive value.

  9. Gastro-Oesophageal Reflux and Apnoea: Is There a Temporal Relationship?

    PubMed

    Rossor, Thomas; Andradi, Gwendolyn; Ali, Kamal; Bhat, Ravindra; Greenough, Anne

    2018-01-01

    Gastro-oesophageal reflux (GOR) and apnoea are common in infants; whether there is a causal relationship is controversial. To determine whether there was a temporal relationship between GOR and apnoea, in particular, the frequency of obstructive apnoeas and if the frequency of GOR episodes correlated with apnoea frequency when maturity at testing was taken into account. Polysomnography and pH/multichannel intraluminal impedance (MII) studies were performed. Apnoeas were classified as central, obstructive, or mixed. MII events were classified as acidic (pH <4) or weakly acidic (4 < pH < 7). Apnoea frequency in the 5-min period after a reflux event was compared to that in the 5-min period preceding the event and that in a 5-min reflux-free period (control period). Forty infants (median gestational age 29 [range 24-42] weeks) were assessed at a post-conceptional age of 37 (30-54) weeks. Obstructive (n = 580), central (n = 900), and mixed (n = 452) apnoeas were identified; 381 acid reflux events were detected by MII and 153 by the pH probe only. Apnoeas were not more frequent following GOR than during control periods. Both the frequency of apnoeas (p = 0.002) and GOR episodes (p = 0.01) were inversely related to post-conceptional age at testing, but were not significantly correlated with each other when controlled for post-conceptional age. These results suggest that GOR does not cause apnoea. © 2017 S. Karger AG, Basel.

  10. The role of science in treaty verification.

    PubMed

    Gavron, Avigdor

    2005-01-01

    Technologically advanced nations are currently applying more science to treaty verification than ever before. Satellites gather a multitude of information relating to proliferation concerns using thermal imaging analysis, nuclear radiation measurements, and optical and radio frequency signals detection. Ground stations gather complementary signals such as seismic events and radioactive emissions. Export controls in many countries attempt to intercept materials and technical means that could be used for nuclear proliferation. Nevertheless, we have witnessed a plethora of nuclear proliferation episodes, that were undetected (or were belatedly detected) by these technologies--the Indian nuclear tests in 1998, the Libyan nuclear buildup, the Iranian enrichment program and the North Korea nuclear weapons program are some prime examples. In this talk, we will discuss some of the technologies used for proliferation detection. In particular, we will note some of the issues relating to nuclear materials control agreements that epitomize political difficulties as they impact the implementation of science and technology.

  11. An intelligent artificial throat with sound-sensing ability based on laser induced graphene

    PubMed Central

    Tao, Lu-Qi; Tian, He; Liu, Ying; Ju, Zhen-Yi; Pang, Yu; Chen, Yuan-Quan; Wang, Dan-Yang; Tian, Xiang-Guang; Yan, Jun-Chao; Deng, Ning-Qin; Yang, Yi; Ren, Tian-Ling

    2017-01-01

    Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas. PMID:28232739

  12. An intelligent artificial throat with sound-sensing ability based on laser induced graphene.

    PubMed

    Tao, Lu-Qi; Tian, He; Liu, Ying; Ju, Zhen-Yi; Pang, Yu; Chen, Yuan-Quan; Wang, Dan-Yang; Tian, Xiang-Guang; Yan, Jun-Chao; Deng, Ning-Qin; Yang, Yi; Ren, Tian-Ling

    2017-02-24

    Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas.

  13. An intelligent artificial throat with sound-sensing ability based on laser induced graphene

    NASA Astrophysics Data System (ADS)

    Tao, Lu-Qi; Tian, He; Liu, Ying; Ju, Zhen-Yi; Pang, Yu; Chen, Yuan-Quan; Wang, Dan-Yang; Tian, Xiang-Guang; Yan, Jun-Chao; Deng, Ning-Qin; Yang, Yi; Ren, Tian-Ling

    2017-02-01

    Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas.

  14. Optimum Detection Of Slow-Frequency-Hopping Signals

    NASA Technical Reports Server (NTRS)

    Levitt, Barry K.; Cheng, Unjeng

    1994-01-01

    Two papers present theoretical analyses of various schemes for coherent and noncoherent detection of M-ary-frequency-shift-keyed (MFSK) signals with slow frequency hopping. Special attention focused on continuous-phase-modulation (CPM) subset of SFH/MFSK signals, for which frequency modulation such carrier phase remains continuous (albeit unknown) during each hop.

  15. Bilinear Time-frequency Analysis for Lamb Wave Signal Detected by Electromagnetic Acoustic Transducer

    NASA Astrophysics Data System (ADS)

    Sun, Wenxiu; Liu, Guoqiang; Xia, Hui; Xia, Zhengwu

    2018-03-01

    Accurate acquisition of the detection signal travel time plays a very important role in cross-hole tomography. The experimental platform of aluminum plate under the perpendicular magnetic field is established and the bilinear time-frequency analysis methods, Wigner-Ville Distribution (WVD) and the pseudo-Wigner-Ville distribution (PWVD), are applied to analyse the Lamb wave signals detected by electromagnetic acoustic transducer (EMAT). By extracting the same frequency component of the time-frequency spectrum as the excitation frequency, the travel time information can be obtained. In comparison with traditional linear time-frequency analysis method such as short-time Fourier transform (STFT), the bilinear time-frequency analysis method PWVD is more appropriate in extracting travel time and recognizing patterns of Lamb wave.

  16. Next-generation sequencing of the monogenic obesity genes LEP, LEPR, MC4R, PCSK1 and POMC in a Norwegian cohort of patients with morbid obesity and normal weight controls.

    PubMed

    Nordang, Gry B N; Busk, Øyvind L; Tveten, Kristian; Hanevik, Hans Ivar; Fell, Anne Kristin M; Hjelmesæth, Jøran; Holla, Øystein L; Hertel, Jens K

    2017-05-01

    Rare sequence variants in at least five genes are known to cause monogenic obesity. In this study we aimed to investigate the prevalence of, and characterize, rare coding and splice site variants in LEP, LEPR, MC4R, PCSK1 and POMC in patients with morbid obesity and normal weight controls. Targeted next-generation sequencing of all exons in LEP, LEPR, MC4R, PCSK1 and POMC was performed in 485 patients with morbid obesity and 327 normal weight population-based controls from Norway. In total 151 variants were detected. Twenty-eight (18.5%) of these were rare, coding or splice variants and five (3.3%) were novel. All individuals, except one control, were heterozygous for the 28 variants, and the distribution of the rare variants showed a significantly higher carrier frequency among cases than controls (9.9% vs. 4.9%, p=0.011). Four variants in MC4R were classified as pathogenic or likely pathogenic. Four cases (0.8%) of monogenic obesity were detected, all due to MC4R variants previously linked to monogenic obesity. Significant differences in carrier frequencies among patients with morbid obesity and normal weight controls suggest an association between heterozygous rare coding variants in these five genes and morbid obesity. However, additional studies in larger cohorts and functional testing of the novel variants identified are required to confirm the findings. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Detection of Methicillin-resistant Staphylococcus aureus and Vancomycin-resistant Enterococci by Healthcare Workers on Infection Control Gown and Gloves

    PubMed Central

    Snyder, Graham M.; Thom, Kerri A.; Furuno, Jon P.; Perencevich, Eli N.; Roghmann, Mary-Claire; Strauss, Sandra M.; Netzer, Giora; Harris, Anthony D.

    2008-01-01

    Objective To assess the frequency of detection and risk factors for detection of methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) by healthcare workers on infection control protective gown and gloves. Design We observed interactions between healthcare workers and patients during routine clinical activities. Cultures were taken of healthcare workers’ hands prior to entering the room, disposable infection control gown and gloves after completing patient care activities, and of hands immediately following removal of infection control protective gown and gloves. Setting A 29-bed medical intensive care unit at an urban tertiary-care academic hospital, the University of Maryland Medical Center. Results Seventeen percent (24/137, 95%CI ± 6.4%) of healthcare workers caring for a patient with MRSA and/or VRE acquired that organism on their gloves, gown or both. Contacting an endotracheal tube or tracheostomy (P < 0.05), contacting the head and/or neck of a patient (P < 0.05), and the presence of a percutaneous endoscopic gastrostomy/jejunostomy tube (P < 0.05) were associated with increased risk of detection of antibiotic-resistant organisms. Conclusions Gloves and gowns are frequently contaminated with MRSA and VRE during routine care duties. Contact with the head or neck, care for an endotracheal tube or tracheostomy, and the presence of an endotracheal tube or tracheostomy may increase the risk of detection of antibiotic-resistant organisms. PMID:18549314

  18. Control system failure monitoring using generalized parity relations. M.S. Thesis Interim Technical Report

    NASA Technical Reports Server (NTRS)

    Vanschalkwyk, Christiaan Mauritz

    1991-01-01

    Many applications require that a control system must be tolerant to the failure of its components. This is especially true for large space-based systems that must work unattended and with long periods between maintenance. Fault tolerance can be obtained by detecting the failure of the control system component, determining which component has failed, and reconfiguring the system so that the failed component is isolated from the controller. Component failure detection experiments that were conducted on an experimental space structure, the NASA Langley Mini-Mast are presented. Two methodologies for failure detection and isolation (FDI) exist that do not require the specification of failure modes and are applicable to both actuators and sensors. These methods are known as the Failure Detection Filter and the method of Generalized Parity Relations. The latter method was applied to three different sensor types on the Mini-Mast. Failures were simulated in input-output data that were recorded during operation of the Mini-Mast. Both single and double sensor parity relations were tested and the effect of several design parameters on the performance of these relations is discussed. The detection of actuator failures is also treated. It is shown that in all the cases it is possible to identify the parity relations directly from input-output data. Frequency domain analysis is used to explain the behavior of the parity relations.

  19. Detrimental Effect Elimination of Laser Frequency Instability in Brillouin Optical Time Domain Reflectometer by Using Self-Heterodyne Detection

    PubMed Central

    Li, Yongqian; Li, Xiaojuan; An, Qi; Zhang, Lixin

    2017-01-01

    A useful method for eliminating the detrimental effect of laser frequency instability on Brillouin signals by employing the self-heterodyne detection of Rayleigh and Brillouin scattering is presented. From the analysis of Brillouin scattering spectra from fibers with different lengths measured by heterodyne detection, the maximum usable pulse width immune to laser frequency instability is obtained to be about 4 µs in a self-heterodyne detection Brillouin optical time domain reflectometer (BOTDR) system using a broad-band laser with low frequency stability. Applying the self-heterodyne detection of Rayleigh and Brillouin scattering in BOTDR system, we successfully demonstrate that the detrimental effect of laser frequency instability on Brillouin signals can be eliminated effectively. Employing the broad-band laser modulated by a 130-ns wide pulse driven electro-optic modulator, the observed maximum errors in temperatures measured by the local heterodyne and self-heterodyne detection BOTDR systems are 7.9 °C and 1.2 °C, respectively. PMID:28335508

  20. Dispersive detection of radio-frequency-dressed states

    NASA Astrophysics Data System (ADS)

    Jammi, Sindhu; Pyragius, Tadas; Bason, Mark G.; Florez, Hans Marin; Fernholz, Thomas

    2018-04-01

    We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.

  1. RF signal detection by a tunable optoelectronic oscillator based on a PS-FBG.

    PubMed

    Shao, Yuchen; Han, Xiuyou; Li, Ming; Zhao, Mingshan

    2018-03-15

    Low-power radio frequency (RF) signal detection is highly desirable for many applications, ranging from wireless communication to radar systems. A tunable optoelectronic oscillator (OEO) based on a phase-shifted fiber Bragg grating for detecting low-power RF signals is proposed and experimentally demonstrated. When the frequency of the input RF signal is matched with the potential oscillation mode of the OEO, it is detected and amplified. The frequency of the RF signal under detection can be estimated simultaneously by scanning the wavelength of the laser source. The RF signals from 1.5 to 5 GHz as low as -91  dBm are detected with a gain of about 10 dB, and the frequency is estimated with an error of ±100  MHz. The performance of the OEO system for detecting an RF signal with different modulation rates is also investigated.

  2. Recent Upgrades and Extensions of the ASDEX Upgrade ECRH System

    NASA Astrophysics Data System (ADS)

    Wagner, Dietmar; Stober, Jörg; Leuterer, Fritz; Monaco, Francesco; Münich, Max; Schmid-Lorch, Dominik; Schütz, Harald; Zohm, Hartmut; Thumm, Manfred; Scherer, Theo; Meier, Andreas; Gantenbein, Gerd; Flamm, Jens; Kasparek, Walter; Höhnle, Hendrik; Lechte, Carsten; Litvak, Alexander G.; Denisov, Gregory G.; Chirkov, Alexey; Popov, Leonid G.; Nichiporenko, Vadim O.; Myasnikov, Vadim E.; Tai, Evgeny M.; Solyanova, Elena A.; Malygin, Sergey A.

    2011-03-01

    The multi-frequency Electron Cyclotron Heating (ECRH) system at the ASDEX Upgrade tokamak employs depressed collector gyrotrons, step-tunable in the range 105-140 GHz. The system is equipped with a fast steerable launcher allowing for remote steering of the ECRH RF beam during the plasma discharge. The gyrotrons and the mirrors are fully integrated in the discharge control system. The polarization can be controlled in a feed-forward mode. 3 Sniffer probes for millimeter wave stray radiation detection have been installed.

  3. Prototype fiber Bragg Grattings (FBG) sensor based on intensity modulation of the laser diode low frequency vibrations measurement

    NASA Astrophysics Data System (ADS)

    Setiono, Andi; Ula, Rini Khamimatul; Hanto, Dwi; Widiyatmoko, Bambang; Purnamaningsih, Retno Wigajatri

    2016-02-01

    In general, Fiber Bragg Grating (FBG) sensor works based on observation of spectral response characteristic to detect the desired parameter. In this research, we studied intensity response characteristic of FBG to detect the dynamic strain. Experiment result show that the reflected intensity had linier relationships with dynamic strain. Based on these characteristics, we developed the FBG sensor to detect low frequency vibration. This sensor is designed by attaching the FBG on the bronze cantilever with dimensions of 85×3×0.5 mm. Measurement results showed that the sensor was able to detect vibrations in the frequency range of 7-10 Hz at temperature range of 25-45 ˚C. The measured frequency range is still within the frequency range of digging activity, therefore this vibration sensor can be applied for oil pipelines vandalisation detection system.

  4. Auditory detection of ultrasonic coded transmitters by seals and sea lions.

    PubMed

    Cunningham, Kane A; Hayes, Sean A; Michelle Wargo Rub, A; Reichmuth, Colleen

    2014-04-01

    Ultrasonic coded transmitters (UCTs) are high-frequency acoustic tags that are often used to conduct survivorship studies of vulnerable fish species. Recent observations of differential mortality in tag control studies suggest that fish instrumented with UCTs may be selectively targeted by marine mammal predators, thereby skewing valuable survivorship data. In order to better understand the ability of pinnipeds to detect UCT outputs, behavioral high-frequency hearing thresholds were obtained from a trained harbor seal (Phoca vitulina) and a trained California sea lion (Zalophus californianus). Thresholds were measured for extended (500 ms) and brief (10 ms) 69 kHz narrowband stimuli, as well as for a stimulus recorded directly from a Vemco V16-3H UCT, which consisted of eight 10 ms, 69 kHz pure-tone pulses. Detection thresholds for the harbor seal were as expected based on existing audiometric data for this species, while the California sea lion was much more sensitive than predicted. Given measured detection thresholds of 113 dB re 1 μPa and 124 dB re 1 μPa, respectively, both species are likely able to detect acoustic outputs of the Vemco V16-3H under water from distances exceeding 200 m in typical natural conditions, suggesting that these species are capable of using UCTs to detect free-ranging fish.

  5. Detection and classification of concealed weapons using a magnetometer-based portal

    NASA Astrophysics Data System (ADS)

    Kotter, Dale K.; Roybal, Lyle G.; Polk, Robert E.

    2002-08-01

    A concealed weapons detection technology was developed through the support of the National Institute of Justice (NIJ) to provide a non intrusive means for rapid detection, location, and archiving of data (including visual) of potential suspects and weapon threats. This technology, developed by the Idaho National Engineering and Environmental Laboratory (INEEL), has been applied in a portal style weapons detection system using passive magnetic sensors as its basis. This paper will report on enhancements to the weapon detection system to enable weapon classification and to discriminate threats from non-threats. Advanced signal processing algorithms were used to analyze the magnetic spectrum generated when a person passes through a portal. These algorithms analyzed multiple variables including variance in the magnetic signature from random weapon placement and/or orientation. They perform pattern recognition and calculate the probability that the collected magnetic signature correlates to a known database of weapon versus non-weapon responses. Neural networks were used to further discriminate weapon type and identify controlled electronic items such as cell phones and pagers. False alarms were further reduced by analyzing the magnetic detector response by using a Joint Time Frequency Analysis digital signal processing technique. The frequency components and power spectrum for a given sensor response were derived. This unique fingerprint provided additional information to aid in signal analysis. This technology has the potential to produce major improvements in weapon detection and classification.

  6. Parkinsonian rest tremor can be detected accurately based on neuronal oscillations recorded from the subthalamic nucleus.

    PubMed

    Hirschmann, J; Schoffelen, J M; Schnitzler, A; van Gerven, M A J

    2017-10-01

    To investigate the possibility of tremor detection based on deep brain activity. We re-analyzed recordings of local field potentials (LFPs) from the subthalamic nucleus in 10 PD patients (12 body sides) with spontaneously fluctuating rest tremor. Power in several frequency bands was estimated and used as input to Hidden Markov Models (HMMs) which classified short data segments as either tremor-free rest or rest tremor. HMMs were compared to direct threshold application to individual power features. Applying a threshold directly to band-limited power was insufficient for tremor detection (mean area under the curve [AUC] of receiver operating characteristic: 0.64, STD: 0.19). Multi-feature HMMs, in contrast, allowed for accurate detection (mean AUC: 0.82, STD: 0.15), using four power features obtained from a single contact pair. Within-patient training yielded better accuracy than across-patient training (0.84vs. 0.78, p=0.03), yet tremor could often be detected accurately with either approach. High frequency oscillations (>200Hz) were the best performing individual feature. LFP-based markers of tremor are robust enough to allow for accurate tremor detection in short data segments, provided that appropriate statistical models are used. LFP-based markers of tremor could be useful control signals for closed-loop deep brain stimulation. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  7. Development of a model to simulate infection dynamics of Mycobacterium bovis in cattle herds in the United States

    PubMed Central

    Smith, Rebecca L.; Schukken, Ynte H.; Lu, Zhao; Mitchell, Rebecca M.; Grohn, Yrjo T.

    2013-01-01

    Objective To develop a mathematical model to simulate infection dynamics of Mycobacterium bovis in cattle herds in the United States and predict efficacy of the current national control strategy for tuberculosis in cattle. Design Stochastic simulation model. Sample Theoretical cattle herds in the United States. Procedures A model of within-herd M bovis transmission dynamics following introduction of 1 latently infected cow was developed. Frequency- and density-dependent transmission modes and 3 tuberculin-test based culling strategies (no test-based culling, constant (annual) testing with test-based culling, and the current strategy of slaughterhouse detection-based testing and culling) were investigated. Results were evaluated for 3 herd sizes over a 10-year period and validated via simulation of known outbreaks of M bovis infection. Results On the basis of 1,000 simulations (1000 herds each) at replacement rates typical for dairy cattle (0.33/y), median time to detection of M bovis infection in medium-sized herds (276 adult cattle) via slaughterhouse surveillance was 27 months after introduction, and 58% of these herds would spontaneously clear the infection prior to that time. Sixty-two percent of medium-sized herds without intervention and 99% of those managed with constant test-based culling were predicted to clear infection < 10 years after introduction. The model predicted observed outbreaks best for frequency-dependent transmission, and probability of clearance was most sensitive to replacement rate. Conclusions and Clinical Relevance Although modeling indicated the current national control strategy was sufficient for elimination of M bovis infection from dairy herds after detection, slaughterhouse surveillance was not sufficient to detect M bovis infection in all herds and resulted in subjectively delayed detection, compared with the constant testing method. Further research is required to economically optimize this strategy. PMID:23865885

  8. Stably accessing octave-spanning microresonator frequency combs in the soliton regime.

    PubMed

    Li, Qing; Briles, Travis C; Westly, Daron A; Drake, Tara E; Stone, Jordan R; Ilic, B Robert; Diddams, Scott A; Papp, Scott B; Srinivasan, Kartik

    2017-02-01

    Microresonator frequency combs can be an enabling technology for optical frequency synthesis and timekeeping in low size, weight, and power architectures. Such systems require comb operation in low-noise, phase-coherent states such as solitons, with broad spectral bandwidths (e.g., octave-spanning) for self-referencing to detect the carrier-envelope offset frequency. However, accessing such states is complicated by thermo-optic dispersion. For example, in the Si 3 N 4 platform, precisely dispersion-engineered structures can support broadband operation, but microsecond thermal time constants often require fast pump power or frequency control to stabilize the solitons. In contrast, here we consider how broadband soliton states can be accessed with simple pump laser frequency tuning, at a rate much slower than the thermal dynamics. We demonstrate octave-spanning soliton frequency combs in Si 3 N 4 microresonators, including the generation of a multi-soliton state with a pump power near 40 mW and a single-soliton state with a pump power near 120 mW. We also develop a simplified two-step analysis to explain how these states are accessed without fast control of the pump laser, and outline the required thermal properties for such operation. Our model agrees with experimental results as well as numerical simulations based on a Lugiato-Lefever equation that incorporates thermo-optic dispersion. Moreover, it also explains an experimental observation that a member of an adjacent mode family on the red-detuned side of the pump mode can mitigate the thermal requirements for accessing soliton states.

  9. Auditory Temporal Resolution in Individuals with Diabetes Mellitus Type 2.

    PubMed

    Mishra, Rajkishor; Sanju, Himanshu Kumar; Kumar, Prawin

    2016-10-01

    Introduction  "Diabetes mellitus is a group of metabolic disorders characterized by elevated blood sugar and abnormalities in insulin secretion and action" (American Diabetes Association). Previous literature has reported connection between diabetes mellitus and hearing impairment. There is a dearth of literature on auditory temporal resolution ability in individuals with diabetes mellitus type 2. Objective  The main objective of the present study was to assess auditory temporal resolution ability through GDT (Gap Detection Threshold) in individuals with diabetes mellitus type 2 with high frequency hearing loss. Methods  Fifteen subjects with diabetes mellitus type 2 with high frequency hearing loss in the age range of 30 to 40 years participated in the study as the experimental group. Fifteen age-matched non-diabetic individuals with normal hearing served as the control group. We administered the Gap Detection Threshold (GDT) test to all participants to assess their temporal resolution ability. Result  We used the independent t -test to compare between groups. Results showed that the diabetic group (experimental) performed significantly poorer compared with the non-diabetic group (control). Conclusion  It is possible to conclude that widening of auditory filters and changes in the central auditory nervous system contributed to poorer performance for temporal resolution task (Gap Detection Threshold) in individuals with diabetes mellitus type 2. Findings of the present study revealed the deteriorating effect of diabetes mellitus type 2 at the central auditory processing level.

  10. Frequency-doubling technology perimetry and multifocal visual evoked potential in glaucoma, suspected glaucoma, and control patients

    PubMed Central

    Kanadani, Fabio N; Mello, Paulo AA; Dorairaj, Syril K; Kanadani, Tereza CM

    2014-01-01

    Introduction The gold standard in functional glaucoma evaluation is standard automated perimetry (SAP). However, SAP depends on the reliability of the patients’ responses and other external factors; therefore, other technologies have been developed for earlier detection of visual field changes in glaucoma patients. The frequency-doubling perimetry (FDT) is believed to detect glaucoma earlier than SAP. The multifocal visual evoked potential (mfVEP) is an objective test for functional evaluation. Objective To evaluate the sensitivity and specificity of FDT and mfVEP tests in normal, suspect, and glaucomatous eyes and compare the monocular and interocular mfVEP. Methods Ninety-five eyes from 95 individuals (23 controls, 33 glaucoma suspects, 39 glaucomatous) were enrolled. All participants underwent a full ophthalmic examination, followed by SAP, FDT, and mfVEP tests. Results The area under the curve for mean deviation and pattern standard deviation were 0.756 and 0.761, respectively, for FDT, 0.564 and 0.512 for signal and alpha for interocular mfVEP, and 0.568 and 0.538 for signal and alpha for monocular mfVEP. This difference between monocular and interocular mfVEP was not significant. Conclusion The FDT Matrix was superior to mfVEP in glaucoma detection. The difference between monocular and interocular mfVEP in the diagnosis of glaucoma was not significant. PMID:25075173

  11. Modulator for tone and binary signals. [phase of modulation of tone and binary signals on carrier waves in communication systems

    NASA Technical Reports Server (NTRS)

    Mcchesney, J. R.; Lerner, T.; Fitch, E. J. (Inventor)

    1975-01-01

    Tones and binary information are transmitted as phase variations on a carrier wave of constant amplitude and frequency. The carrier and tones are applied to a balanced modulator for deriving an output signal including a pair of sidebands relative to the carrier. The carrier is phase modulated by a digital signal so that it is + or - 90 deg out of phase with the predetermined phase of the carrier. The carrier is combined in an algebraic summing device with the phase modulated signal and the balanced modulator output signal. The output of the algebraic summing device is hard limited to derive a constant amplitude and frequency signal having very narrow bandwidth requirements. At a receiver, the tones and binary data are detected with a phase locked loop having a voltage controlled oscillator driving a pair of orthogonal detection channels.

  12. [Study on the optimization of monitoring indicators of drinking water quality during health supervision].

    PubMed

    Ye, Bixiong; E, Xueli; Zhang, Lan

    2015-01-01

    To optimize non-regular drinking water quality indices (except Giardia and Cryptosporidium) of urban drinking water. Several methods including drinking water quality exceed the standard, the risk of exceeding standard, the frequency of detecting concentrations below the detection limit, water quality comprehensive index evaluation method, and attribute reduction algorithm of rough set theory were applied, redundancy factor of water quality indicators were eliminated, control factors that play a leading role in drinking water safety were found. Optimization results showed in 62 unconventional water quality monitoring indicators of urban drinking water, 42 water quality indicators could be optimized reduction by comprehensively evaluation combined with attribute reduction of rough set. Optimization of the water quality monitoring indicators and reduction of monitoring indicators and monitoring frequency could ensure the safety of drinking water quality while lowering monitoring costs and reducing monitoring pressure of the sanitation supervision departments.

  13. Portable fiber-coupled diode-laser-based sensor for multiple trace gas detection

    NASA Technical Reports Server (NTRS)

    Lancaster, D. G.; Richter, D.; Tittel, F. K.

    1999-01-01

    Tunable narrowband mid-infrared radiation from 3.25 to 4.4 micrometers is generated by a compact fiber-coupled, difference-frequency-based spectroscopic source. A 20-mW external cavity diode laser (with a tuning range from 814 to 870 nm) and a 50-mW distributed-Bragg-reflector diode-laser-seeded ytterbium-doped fiber amplifier operating at 1083 nm are difference-frequency mixed in a multi-grating, temperature-controlled periodically poled LiNbO3 crystal. A conversion efficiency of 0.44 mW/(W2cm) (corresponding to a power of approximately equal to 3 microW at 3.3 micrometers) represents the highest conversion efficiency reported for a portable device. Performance characteristics of such a sensor and its application to spectroscopic detection of CO2, N2O, H2CO, HCl, NO2, and CH4 will be reported in this work.

  14. Clastogenic and mitodepressive effects of the insecticide dichlorvos on root meristems of Vicia faba.

    PubMed

    Kontek, Renata; Osiecka, Regina; Kontek, Bodgan

    2007-01-01

    Plant bioassays are an important and integral part of the test battery used in detecting genotoxic/carcinogenic contamination in the environment. Highly sensitive biomonitoring of plant models have been developed, which enables the detection of hazards arising from pesticides, insecticides, industrial contamination, heavy metals and radiation. Root tips of Vicia faba ssp. minor were treated with 1-60 mM of the organophosphorus insecticide dichlorvos (DDVP) for 2 h, followed by a 20-h recovery period. Maleic acid hydrazide (MH) was used as a positive control for the mitotic index, micronucleus and chromosomal aberration assays performed on the Vicia model system. All treatments with DDVP significantly decreased the mitotic activity and increased the frequency of chromosomal aberrations at the metaphase. The frequency of micronuclei was significantly increased at DDVP concentrations starting from 10 mM. The results demonstrate clastogenic and mitodepressive effects of DDVP on Vicia faba cells.

  15. [Effect of Tongluo Xingnao effervescent tablets on learning and memory dysfunction in rats with chronic cerebral ischemia].

    PubMed

    Hu, Yong; Ju, Shao-Hua; Zhang, Yin-Jie; Xiong, Min; Xu, Shi-Jun; Ma, Yun-Tong; Zhong, Zhen-Dong

    2014-05-01

    To study the effect of Tongluo Xingnao effervescent tablets on learning and memory capacity and expression of Na(+)-K(+)-ATPase in hippocampus of rats with chronic cerebral ischemia-induced learning and memory dysfunction model. The 2-VO method was used to establish sd rat model learning and memory dysfunction induced by chronic cerebral ischemia. The 50 rats in the successfully established model were randomly divided into the model control group, the Dihydroergotoxine Mesylate tablets group (0.7 mg x kg(-1), Tongluo Xingnao effervescent tablets high dose (7.56 g x kg(-1)), middle dose (3.78 g x kg(-1)) and low dose (1.59 g x kg(-1)) groups and the sham operation group (n = 10) as the control group. The groups were orally given 10 ml x kg(-1) x d(-1) drugs for consecutively 90 days. On the 86th day, Morris water maze was adopted for them. On the 90th day, a leaning and memory capacity test was held. The brain tissues were fixed with 10% formaldehyde and observed for pathomorphism after routine slide preparation and staining. The expression of hippocampal Na(+)-K(+)-ATPase was detected with immunohistochemistry and image quantitative analysis. Compared with the model group, all of Tongluo Xingnao effervescent tablets groups showed significant decrease in the escape latency at the 5th day in the Morris water maze, and notable increase in the frequency of the first quadrant dwell, the frequency passing the escape platform and the frequency entering effective area (p < 0.05). According to the pathomorphological detection, the control group showed a significantly higher pathological score than the sham operation group (p < 0.01), the middle dose group showed a significantly lower pathological score than the model group (p < 0.05). According to the immunohistochemistical detection, the model control group showed a remarkably lower mean OD value of Na(+)-K(+)-ATPase than the sham operation group (p < 0.05), high and middle dose groups showed a significantly higher mean od value than the model control group (p < 0.01). Tongluo Xingnao effervescent tablets can improve the learning and memory capacity, reduce pathological changes of hippocampal tissues of rats with chronic cerebral ischemia-induced learning and memory dysfunction model, and promote the expression of Na(+)-K(+)-ATPase in hippocampus.

  16. Acoustic resonance phase locked photoacoustic spectrometer

    DOEpatents

    Pilgrim, Jeffrey S.; Bomse, David S.; Silver, Joel A.

    2003-08-19

    A photoacoustic spectroscopy method and apparatus for maintaining an acoustic source frequency on a sample cell resonance frequency comprising: providing an acoustic source to the sample cell to generate a photoacoustic signal, the acoustic source having a source frequency; continuously measuring detection phase of the photoacoustic signal with respect to source frequency or a harmonic thereof; and employing the measured detection phase to provide magnitude and direction for correcting the source frequency to the resonance frequency.

  17. Jaw tremor as a physiological biomarker of bruxism.

    PubMed

    Laine, C M; Yavuz, Ş U; D'Amico, J M; Gorassini, M A; Türker, K S; Farina, D

    2015-09-01

    To determine if sleep bruxism is associated with abnormal physiological tremor of the jaw during a visually-guided bite force control task. Healthy participants and patients with sleep bruxism were given visual feedback of their bite force and asked to trace triangular target trajectories (duration=20s, peak force <35% maximum voluntary force). Bite force control was quantified in terms of the power spectra of force fluctuations, masseter EMG activity, and force-to-EMG coherence. Patients had greater jaw force tremor at ∼8 Hz relative to controls, along with increased masseter EMG activity and force-to-EMG coherence in the same frequency range. Patients also showed lower force-to-EMG coherence at low frequencies (<3 Hz), but greater coherence at high frequencies (20-40 Hz). Finally, patients had greater 6-10 Hz force tremor during periods of descending vs. ascending force, while controls showed no difference in tremor with respect to force dynamics. Patients with bruxism have abnormal jaw tremor when engaged in a visually-guided bite force task. Measurement of jaw tremor may aid in the detection/evaluation of bruxism. In light of previous literature, our results also suggest that bruxism is marked by abnormal or mishandled peripheral feedback from the teeth. Copyright © 2015. Published by Elsevier Ireland Ltd.

  18. Evaluation of genetic damage in Brazilian footwear-workers: biomarkers of exposure, effect, and susceptibility.

    PubMed

    Heuser, Vanina Dahlström; Erdtmann, Bernardo; Kvitko, Kátia; Rohr, Paula; da Silva, Juliana

    2007-04-11

    Employees in the footwear manufacturing industry are routinely exposed to complex mixtures of solvents used in cleaning and as diluents in glues, primers, and degreasers. The objective of this study was to determine the genotoxic effects in a group of footwear-workers occupationally exposed to solvent-based adhesive and solutions containing organic solvents, mainly toluene. Peripheral blood and buccal cells samples were collected from 39 footwear-workers (31 males and 8 females) and 55 controls (44 males and 11 females). As biomarker of exposure, we obtained data on hippuric acid (HA), the main metabolite of toluene in urine, and DNA damage detected by the Comet assay in blood cells. Micronucleus frequencies in binucleated lymphocytes (BNMN) and in epithelial buccal cells (EBCMN) were analyzed as biomarkers of effect, while polymorphisms in genes GSTT1, GSTM1, GSTP1, CYP1A1, and CYP2E1 were used as susceptibility biomarkers. Results of HA and Comet assay showed statistical increased values amongst footwear-workers relative to controls (P < or = 0.001). No differences were observed in BNMN and EBCMN frequencies between the groups, but a correlation test revealed that age was significantly associated with BNMN frequency in both control (r(s)=0.290; P < or = 0.05) and exposed groups (r(s)=0.674; P < or = 0.001). Regarding the results on genetic polymorphisms, GSTM1 null subjects from the control group showed a significant increase in EBCMN frequency relative to GSTM1 non-null subjects (P < or = 0.05). A significant increase in DNA damage detected by Comet assay in leukocytes was obtained for GSTP1 Ile/Val or Val/Val individuals from the exposed group relative to those with GSTP1 Ile/Ile (P < or = 0.05), especially in younger subjects (P < or = 0.01), and a suggestion of interaction with CYP2E1 polymorphism was found. In confirmation of these data, stepwise multiple regression analyses for selecting between the different independent variables showed that about 25% of levels of the DNA damage in footwear-worker can be associated with genetic polymorphisms in GSTP1 and CYP2E1 (P=0.006, F=5.876).

  19. Observations of toroidicity-induced Alfvén eigenmodes in a reversed field pinch plasma

    NASA Astrophysics Data System (ADS)

    Regnoli, G.; Bergsâker, H.; Tennfors, E.; Zonca, F.; Martines, E.; Serianni, G.; Spolaore, M.; Vianello, N.; Cecconello, M.; Antoni, V.; Cavazzana, R.; Malmberg, J.-A.

    2005-04-01

    High frequency peaks in the spectra of magnetic field signals have been detected at the edge of Extrap-T2R [P. R. Brunsell, H. Bergsåker, M. Cecconello, J. R. Drake, R. M. Gravestijn, A. Hedqvist, and J.-A. Malmberg, Plasma Phys. Controlled Fusion, 43, 1457 (2001)]. The measured fluctuation is found to be mainly polarized along the toroidal direction, with high toroidal periodicity n and Alfvénic scaling (f∝B/√mini ). Calculations for a reversed field pinch plasma predict the existence of an edge resonant, high frequency, high-n number toroidicity-induced Alfvén eigenmode with the observed frequency scaling. In addition, gas puffing experiments show that edge density fluctuations are responsible for the rapid changes of mode frequency. Finally a coupling with the electron drift turbulence is proposed as drive mechanism for the eigenmode.

  20. Lexical processing and distributional knowledge in sound-spelling mapping in a consistent orthography: A longitudinal study of reading and spelling in dyslexic and typically developing children.

    PubMed

    Marinelli, Chiara Valeria; Cellini, Pamela; Zoccolotti, Pierluigi; Angelelli, Paola

    This study examined the ability to master lexical processing and use knowledge of the relative frequency of sound-spelling mappings in both reading and spelling. Twenty-four dyslexic and dysgraphic children and 86 typically developing readers were followed longitudinally in 3rd and 5th grades. Effects of word regularity, word frequency, and probability of sound-spelling mappings were examined in two experimental tasks: (a) spelling to dictation; and (b) orthographic judgment. Dyslexic children showed larger regularity and frequency effects than controls in both tasks. Sensitivity to distributional information of sound-spelling mappings was already detected by third grade, indicating early acquisition even in children with dyslexia. Although with notable differences, knowledge of the relative frequencies of sound-spelling mapping influenced both reading and spelling. Results are discussed in terms of their theoretical and empirical implications.

  1. Underwater audiogram of the California sea lion by the conditioned vocalization technique1

    PubMed Central

    Schusterman, Ronald J.; Balliet, Richard F.; Nixon, James

    1972-01-01

    Conditioning techniques were developed demonstrating that pure tone frequencies under water can exert nearly perfect control over the underwater click vocalizations of the California sea lion (Zalophus californianus). Conditioned vocalizations proved to be a reliable way of obtaining underwater sound detection thresholds in Zalophus at 13 different frequencies, covering a frequency range of 250 to 64,000 Hz. The audiogram generated by these threshold measurements suggests that under water, the range of maximal sensitivity for Zalophus lies between one and 28 kHz with best sensitivity at 16 kHz. Between 28 and 36 kHz there is a loss in sensitivity of 60 dB/octave. However, with relatively intense acoustic signals (> 38 dB re 1 μb underwater), Zalophus will respond to frequencies at least as high as 192 kHz. These results are compared with the underwater hearing of other marine mammals. ImagesFig. 1. PMID:5033891

  2. Modulated microwave microscopy and probes used therewith

    DOEpatents

    Lai, Keji; Kelly, Michael; Shen, Zhi-Xun

    2012-09-11

    A microwave microscope including a probe tip electrode vertically positionable over a sample and projecting downwardly from the end of a cantilever. A transmission line connecting the tip electrode to the electronic control system extends along the cantilever and is separated from a ground plane at the bottom of the cantilever by a dielectric layer. The probe tip may be vertically tapped near or at the sample surface at a low frequency and the microwave signal reflected from the tip/sample interaction is demodulated at the low frequency. Alternatively, a low-frequency electrical signal is also a non-linear electrical element associated with the probe tip to non-linearly interact with the applied microwave signal and the reflected non-linear microwave signal is detected at the low frequency. The non-linear element may be semiconductor junction formed near the apex of the probe tip or be an FET formed at the base of a semiconducting tip.

  3. Association Study of Klotho Gene Polymorphism With Calcium Oxalate Stones in The Uyghur Population of Xinjiang, China.

    PubMed

    Ali, Abdusamat; Tursun, Halmurat; Talat, Alim; Abla, Akpar; Muhtar, Erpan; Zhang, Tao; Mahmut, Murat

    2017-01-18

    The aim of the present study was to investigate the correlation between Klotho gene polymorphisms andcalcium oxalate stones in Xinjiang Uyghur people. We compared 128 patients with calcium oxalate stones (case group) and 94 healthypeople (control group), detected the genotype and allele distributions of single-nucleotide polymorphisms (SNPs)of the Klotho gene (rs3752472, rs650439, and rs1207568) by reverse transcription polymerase chain reaction. The distributions of the genotype and allele frequencies of the SNPs were consistent with the Hardy-Weinberg equilibrium in the two groups. There were statistically significant differences between the genotype andallele distributions of rs3752472 between the case and control groups; the allele frequencies in the case/controlgroups were C = 240 (93.7%)/151 (80.3%) and T = 16 (6.3%)/37 (19.7%). There was no statistically significantdifference in the genotype distribution of rs650439 between the case and control groups, but there was a differencein the allele distribution; the allele frequencies in the case/control groups were A = 202 (78.9%)/143 (57.2%) andT = 54 (21.1%)/107 (42.8%). There were no statistically significant differences in genotype and allele distributionsbetween the case and control groups of rs1207568; the allele frequencies in the case/control groups were C = 194(71.3%)/145 (77.1%) and T = 78 (28.7%)/43 (22.9%). In rs3752472, the risk for patients with the C and A allelesincreased by 3.675 and 2.799 times, respectively. The rs3752472 and rs650439 SNPs are related to the risk of calcium oxalate stones in Xinjiang Uyghurpeople, and might be one of the risk factors.

  4. Economic Statistical Design of Integrated X-bar-S Control Chart with Preventive Maintenance and General Failure Distribution

    PubMed Central

    Caballero Morales, Santiago Omar

    2013-01-01

    The application of Preventive Maintenance (PM) and Statistical Process Control (SPC) are important practices to achieve high product quality, small frequency of failures, and cost reduction in a production process. However there are some points that have not been explored in depth about its joint application. First, most SPC is performed with the X-bar control chart which does not fully consider the variability of the production process. Second, many studies of design of control charts consider just the economic aspect while statistical restrictions must be considered to achieve charts with low probabilities of false detection of failures. Third, the effect of PM on processes with different failure probability distributions has not been studied. Hence, this paper covers these points, presenting the Economic Statistical Design (ESD) of joint X-bar-S control charts with a cost model that integrates PM with general failure distribution. Experiments showed statistically significant reductions in costs when PM is performed on processes with high failure rates and reductions in the sampling frequency of units for testing under SPC. PMID:23527082

  5. Non-group A streptococci in the pharynx. Pathogens or innocent bystanders?

    PubMed

    Hayden, G F; Murphy, T F; Hendley, J O

    1989-07-01

    To determine whether beta-hemolytic streptococci from groups other than A are an important cause of sporadic pharyngitis in children. Cross-sectional, case-referent survey. General pediatric clinic at a military base in Ohio. One hundred fifty children with symptomatic pharyngitis and 150 controls matched for age and time of presentation over a 20-month study period. None. Anaerobic culture technique was used to improve isolation of beta-hemolytic streptococci. Group A beta-hemolytic streptococci were detected significantly more often among the ill children than among the controls (39% vs 16%, respectively). In contrast, non-group A beta-hemolytic streptococci were isolated in similar frequency from the ill and control children (17% vs 21%, respectively). Non-group A beta-hemolytic streptococci from groups B, C, F, and G were each isolated in similar frequency among the ill and control children. The isolation rate of non-group A organisms increased with age among both patients and controls. Non-group A beta-hemolytic streptococci seemed not to be an important cause of sporadic pharyngitis in this pediatric population.

  6. A versatile computer-controlled pulsed nuclear quadrupole resonance spectrometer

    NASA Astrophysics Data System (ADS)

    Fisher, Gregory; MacNamara, Ernesto; Santini, Robert E.; Raftery, Daniel

    1999-12-01

    A new, pulsed nuclear quadrupole resonance (NQR) spectrometer capable of performing a variety of pulsed and swept experiments is described. The spectrometer features phase locked, superheterodyne detection using a commercial spectrum analyzer and a fully automatic, computer-controlled tuning and matching network. The tuning and matching network employs stepper motors which turn high power air gap capacitors in a "moving grid" optimization strategy to minimize the reflected power from a directional coupler. In the duplexer circuit, digitally controlled relays are used to switch different lengths of coax cable appropriate for the different radio frequencies. A home-built pulse programmer card controls the timing of radio frequency pulses sent to the probe, while data acquisition and control software is written in Microsoft Quick Basic. Spin-echo acquisition experiments are typically used to acquire the data, although a variety of pulse sequences can be employed. Scan times range from one to several hours depending upon the step resolution and the spectral range required for each experiment. Pure NQR spectra of NaNO2 and 3-aminopyridine are discussed.

  7. An Almost Complete Radio Survey of Magnetic Cataclysmic Variables

    NASA Astrophysics Data System (ADS)

    Dieck, Christopher A.; Everett Barrett, Paul; Beasley, Anthony J.; Pal Singh, Kulinder; Boboltz, David A.; Godon, Patrick; Mason, Paul A.

    2016-01-01

    This poster presents the results of a radio survey using the Jansky Very Large Array (JVLA) of 129 Magnetic Cataclysmic Variables (MCVs) north of declination -35 deg. 103 hours of observations were performed during the JVLA observing sessions 2013B and 2015A, when the array was mostly in its highest spatial-resolution configurations (i.e., A and B). Most targets were observed twice for 2-5 minutes at each of three frequencies (C, X, and K-bands), although a few targets were also observed at a fourth frequency (Q-band). 22 of the 129 MCVS were detected at one or more frequencies. Of these 22 detections, 15 are new. This number nearly triples the number of MCVs that are known radio sources. Most detections are at the C and X-band frequencies, although three sources were detected at the K-band frequency. One of the K-band frequency detections is the known rapidly-rotating radio source AE Aqr, while the other two are the polars, AI Tri and ST LMi. Of the 22 detected sources, two-thirds are polars (15) and all are believed to be nearby (<200 pc). Except for a few stronger sources, most detections are in the range of 100-200 µJy, which at a distance of 150 pc corresponds roughly to a luminosity of 2x1024 erg/s at the X-band frequency. The results of this survey are encouraging in that more MCVs are likely to be detected as the time on-source increases, since the flux from MCVs is highly variable.

  8. Functional connectivity changes detected with magnetoencephalography after mild traumatic brain injury

    PubMed Central

    Dimitriadis, Stavros I.; Zouridakis, George; Rezaie, Roozbeh; Babajani-Feremi, Abbas; Papanicolaou, Andrew C.

    2015-01-01

    Mild traumatic brain injury (mTBI) may affect normal cognition and behavior by disrupting the functional connectivity networks that mediate efficient communication among brain regions. In this study, we analyzed brain connectivity profiles from resting state Magnetoencephalographic (MEG) recordings obtained from 31 mTBI patients and 55 normal controls. We used phase-locking value estimates to compute functional connectivity graphs to quantify frequency-specific couplings between sensors at various frequency bands. Overall, normal controls showed a dense network of strong local connections and a limited number of long-range connections that accounted for approximately 20% of all connections, whereas mTBI patients showed networks characterized by weak local connections and strong long-range connections that accounted for more than 60% of all connections. Comparison of the two distinct general patterns at different frequencies using a tensor representation for the connectivity graphs and tensor subspace analysis for optimal feature extraction showed that mTBI patients could be separated from normal controls with 100% classification accuracy in the alpha band. These encouraging findings support the hypothesis that MEG-based functional connectivity patterns may be used as biomarkers that can provide more accurate diagnoses, help guide treatment, and monitor effectiveness of intervention in mTBI. PMID:26640764

  9. The cervical cancer detection system based on an endoscopic rotary probe

    NASA Astrophysics Data System (ADS)

    Yang, Yanshuang; Hou, Qiang; Zhao, Huijuan; Qin, Zhuanping; Gao, Feng

    2012-03-01

    To acquire the optical diffuse tomographic image of the cervix, a novel endoscopic rotary probe is designed and the frequency domain measurement system is developed. The finite element method and Gauss-Newton method are proposed to reconstruct the image of the phantom. In the optical diffuse tomographic imaging of the cervix, an endoscopic probe is needed and the detection of light at different separation to the irradiation spot is necessary. To simplify the system, only two optical fibers are adopted for light irradiation and collection, respectively. Two small stepper motors are employed to control the rotation of the incident fiber and the detection fiber, respectively. For one position of source fiber, the position of the detection fiber is changed from -61.875° to -50.625° and 50.625° to 61.875° to the source fiber, respectively. Then, the position of the source fiber is changed to another preconcerted position, which deviates the precious source position in an angle of 11.25°, and the detection fiber rotates within the above angles. To acquire the efficient irradiation and collection of the light, a gradient-index (GRIN) lens is connected at the head of the optical fiber. The other end of the GRIN lens is cut to 45°. With this design, light from optical fiber is reflected to the cervix wall, which is perpendicular to the optical fiber or vice versa. Considering the cervical size, the external diameter of the endoscopic probe is made to 20mm. A frequency domain (FD) near-infrared diffuse system is developed aiming at the detection of early cervical cancer, which modulates the light intensity in radio frequency and measures the amplitude attenuation and the phase delay of the diffused light using heterodyne detection. Phantom experiment results demonstrate that the endoscopic rotary scan probe and the system perform well in the endoscopic measurement.

  10. Generation and Coherent Control of Pulsed Quantum Frequency Combs.

    PubMed

    MacLellan, Benjamin; Roztocki, Piotr; Kues, Michael; Reimer, Christian; Romero Cortés, Luis; Zhang, Yanbing; Sciara, Stefania; Wetzel, Benjamin; Cino, Alfonso; Chu, Sai T; Little, Brent E; Moss, David J; Caspani, Lucia; Azaña, José; Morandotti, Roberto

    2018-06-08

    We present a method for the generation and coherent manipulation of pulsed quantum frequency combs. Until now, methods of preparing high-dimensional states on-chip in a practical way have remained elusive due to the increasing complexity of the quantum circuitry needed to prepare and process such states. Here, we outline how high-dimensional, frequency-bin entangled, two-photon states can be generated at a stable, high generation rate by using a nested-cavity, actively mode-locked excitation of a nonlinear micro-cavity. This technique is used to produce pulsed quantum frequency combs. Moreover, we present how the quantum states can be coherently manipulated using standard telecommunications components such as programmable filters and electro-optic modulators. In particular, we show in detail how to accomplish state characterization measurements such as density matrix reconstruction, coincidence detection, and single photon spectrum determination. The presented methods form an accessible, reconfigurable, and scalable foundation for complex high-dimensional state preparation and manipulation protocols in the frequency domain.

  11. [Immunodetection of bacteriophages by a piezoelectric resonator with lateral electric field].

    PubMed

    Gulii, O I; Zaitsev, B D; Shikhabudinov, A M; Teplykh, A A; Borodina, I A; Pavlii, S A; Larionova, O S; Fomin, A S; Staroverov, S A; Dykman, L A; Ignatov, O V

    2016-01-01

    It has been demonstrated that electroacoustic analysis with polyclonal antibodies can be used for bacteriophage detection. The frequency dependences of the real and imaginary parts of electrical impedance of a resonator with a viral suspension with antibodies were shown to be essentially different from the dependences of a resonator with control viral suspension without antibodies. It was shown that ΦAl-Sp59b bacteriophages were detected with the use of antibodies in the presence of foreign virus particles. The ΦAl-Sp59b bacteriophage content in the analyzed suspension was ~1010–106 phages/mL; the time of analysis was no more than 5 min. The optimally informative parameter for obtaining reliable information was the change in the real or imaginary part of electrical impedance at a fixed frequency near the resonance upon the addition of specific antibodies to the analyzed suspension. It was demonstrated that the interaction between bacteriophages and antibodies can be recorded, offering good prospects for the development of a biological sensor for liquid-phase identification and virus detection.

  12. Transmit/receive 3-20 GHz 1.2 mW packaged double-pole-16-throw switching matrix for radar-based target detection

    NASA Astrophysics Data System (ADS)

    Azhari, Afreen; Kuwano, Yuki; Xiao, Xia; Kikkawa, Takamaro

    2018-01-01

    A 3-20 GHz transmit/receive (T/R) double-pole-16-throw (DP16T) switching matrix has been developed on a printed circuit board (PCB) to control sixteen antennas in a radar-based portable breast-cancer detection system. The DP16T switch consists of four 65 nm CMOS 0.01-20 GHz double-pole-four-throw (DP4T) switches. The proposed switch increase the number of T/R combinations to 224 from the 196 of a conventional switching matrix in order to construct high-resolution images. Using this switch and a 4 × 4 slot antenna array, a 10 × 10 mm2 aluminum target was detected with an 8-GHz-center-frequency Gaussian monocycle pulse. The power consumption of the switch is only 1.2 mW. To the best of the authors’ knowledge, this is the first T/R radio frequency (RF) DP16T switching matrix, which was realized with four CMOS DP4T switches on a PCB and was measured with RF PCB connectors.

  13. Polymorphisms in the methylene tetrahydrofolate reductase and methionine synthase reductase genes and their correlation with unexplained recurrent spontaneous abortion susceptibility.

    PubMed

    Zhu, L

    2015-07-28

    We aimed to explore the correlation between unexplained recurrent spontaneous abortion and polymorphisms in the methylene tetrahydrofolate reductase (MTHFR) and methionine synthase reductase (MTRR) genes. A case control study was conducted in 118 patients with unexplained recurrent spontaneous abortion (abortion group) and 174 healthy women (control group). The genetic material was extracted from the oral mucosal epithelial cells obtained from all subjects. The samples were subjected to fluorescence quantitative PCR to detect the single nucleotide polymorphisms (SNPs) in the MTHFR (C677T and A1298C) and MTRR (A66G) gene loci. The distribution frequency (18/118, 15.3%) of the MTHFR 677TT genotype was significantly higher in the abortion group (χ2 = 11.006, P = 0.004) than in the control group (2/174, 1.1%); on the other hand, the distribution frequency of the MTHFR A1298C genotype did not significantly differ between the abortion and control groups (χ(2) = 0.441, P = 0.507). The distribution frequency of the MTRR A66G genotype was also significantly higher in the abortion group (14/118, 11.9%; χ(2) = 10.503, P = 0.005) than in the control group (8/174, 4.6%). The MTHFR C677T and MTRR A66G polymorphisms are significantly correlated with the occurrence of spontaneous abortion.

  14. Islanding detection technique using wavelet energy in grid-connected PV system

    NASA Astrophysics Data System (ADS)

    Kim, Il Song

    2016-08-01

    This paper proposes a new islanding detection method using wavelet energy in a grid-connected photovoltaic system. The method detects spectral changes in the higher-frequency components of the point of common coupling voltage and obtains wavelet coefficients by multilevel wavelet analysis. The autocorrelation of the wavelet coefficients can clearly identify islanding detection, even in the variations of the grid voltage harmonics during normal operating conditions. The advantage of the proposed method is that it can detect islanding condition the conventional under voltage/over voltage/under frequency/over frequency methods fail to detect. The theoretical method to obtain wavelet energies is evolved and verified by the experimental result.

  15. Development of a long-gauge vibration sensor

    NASA Astrophysics Data System (ADS)

    Kung, Peter; Comanici, Maria I.

    2014-06-01

    Recently, we found that by terminating a long length of fiber of up to 2 km with an in-fiber cavity structure, the entire structure can detect vibrations over a frequency range from 5 Hz to 100 Hz. We want to determine whether the structure (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to the maintenance cost. Similarly, it will help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that will require the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Then, at even higher frequencies, the structure can be useful to detect acoustic vibrations (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large re-enforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed long-gauge vibration sensor depends on packaging.

  16. Microcantilever sensor

    DOEpatents

    Thundat, Thomas G.; Wachter, Eric A.

    1998-01-01

    An improved microcantilever sensor is fabricated with at least one microcantilever attached to a piezoelectric transducer. The microcantilever is partially surface treated with a compound selective substance having substantially exclusive affinity for a targeted compound in a monitored atmosphere. The microcantilever sensor is also provided with a frequency detection means and a bending detection means. The frequency detection means is capable of detecting changes in the resonance frequency of the vibrated microcantilever in the monitored atmosphere. The bending detection means is capable of detecting changes in the bending of the vibrated microcantilever in the monitored atmosphere coactively with the frequency detection means. The piezoelectric transducer is excited by an oscillator means which provides a signal driving the transducer at a resonance frequency inducing a predetermined order of resonance on the partially treated microcantilever. Upon insertion into a monitored atmosphere, molecules of the targeted chemical attach to the treated regions of the microcantilever resulting in a change in oscillating mass as well as a change in microcantilever spring constant thereby influencing the resonant frequency of the microcantilever oscillation. Furthermore, the molecular attachment of the target chemical to the treated regions induce areas of mechanical strain in the microcantilever consistent with the treated regions thereby influencing microcantilever bending. The rate at which the treated microcantilever accumulates the target chemical is a function of the target chemical concentration. Consequently, the extent of microcantilever oscillation frequency change and bending is related to the concentration of target chemical within the monitored atmosphere.

  17. Microcantilever sensor

    DOEpatents

    Thundat, T.G.; Wachter, E.A.

    1998-02-17

    An improved microcantilever sensor is fabricated with at least one microcantilever attached to a piezoelectric transducer. The microcantilever is partially surface treated with a compound selective substance having substantially exclusive affinity for a targeted compound in a monitored atmosphere. The microcantilever sensor is also provided with a frequency detection means and a bending detection means. The frequency detection means is capable of detecting changes in the resonance frequency of the vibrated microcantilever in the monitored atmosphere. The bending detection means is capable of detecting changes in the bending of the vibrated microcantilever in the monitored atmosphere coactively with the frequency detection means. The piezoelectric transducer is excited by an oscillator means which provides a signal driving the transducer at a resonance frequency inducing a predetermined order of resonance on the partially treated microcantilever. Upon insertion into a monitored atmosphere, molecules of the targeted chemical attach to the treated regions of the microcantilever resulting in a change in oscillating mass as well as a change in microcantilever spring constant thereby influencing the resonant frequency of the microcantilever oscillation. Furthermore, the molecular attachment of the target chemical to the treated regions induce areas of mechanical strain in the microcantilever consistent with the treated regions thereby influencing microcantilever bending. The rate at which the treated microcantilever accumulates the target chemical is a function of the target chemical concentration. Consequently, the extent of microcantilever oscillation frequency change and bending is related to the concentration of target chemical within the monitored atmosphere. 16 figs.

  18. Phylogeography, intraspecific structure and sex-biased dispersal of Dall's porpoise, Phocoenoides dalli, revealed by mitochondrial and microsatellite DNA analyses.

    PubMed

    Escorza-Treviño, S; Dizon, A E

    2000-08-01

    Mitochondrial DNA (mtDNA) control-region sequences and microsatellite loci length polymorphisms were used to estimate phylogeographical patterns (historical patterns underlying contemporary distribution), intraspecific population structure and gender-biased dispersal of Phocoenoides dalli dalli across its entire range. One-hundred and thirteen animals from several geographical strata were sequenced over 379 bp of mtDNA, resulting in 58 mtDNA haplotypes. Analysis using F(ST) values (based on haplotype frequencies) and phi(ST) values (based on frequencies and genetic distances between haplotypes) yielded statistically significant separation (bootstrap values P < 0.05) among most of the stocks currently used for management purposes. A minimum spanning network of haplotypes showed two very distinctive clusters, differentially occupied by western and eastern populations, with some common widespread haplotypes. This suggests some degree of phyletic radiation from west to east, superimposed on gene flow. Highly male-biased migration was detected for several population comparisons. Nuclear microsatellite DNA markers (119 individuals and six loci) provided additional support for population subdivision and gender-biased dispersal detected in the mtDNA sequences. Analysis using F(ST) values (based on allelic frequencies) yielded statistically significant separation between some, but not all, populations distinguished by mtDNA analysis. R(ST) values (based on frequencies of and genetic distance between alleles) showed no statistically significant subdivision. Again, highly male-biased dispersal was detected for all population comparisons, suggesting, together with morphological and reproductive data, the existence of sexual selection. Our molecular results argue for nine distinct dalli-type populations that should be treated as separate units for management purposes.

  19. Linear and nonlinear frequency- and time-domain spectroscopy with multiple frequency combs.

    PubMed

    Bennett, Kochise; Rouxel, Jeremy R; Mukamel, Shaul

    2017-09-07

    Two techniques that employ equally spaced trains of optical pulses to map an optical high frequency into a low frequency modulation of the signal that can be detected in real time are compared. The development of phase-stable optical frequency combs has opened up new avenues to metrology and spectroscopy. The ability to generate a series of frequency spikes with precisely controlled separation permits a fast, highly accurate sampling of the material response. Recently, pairs of frequency combs with slightly different repetition rates have been utilized to down-convert material susceptibilities from the optical to microwave regime where they can be recorded in real time. We show how this one-dimensional dual comb technique can be extended to multiple dimensions by using several combs. We demonstrate how nonlinear susceptibilities can be quickly acquired using this technique. In a second class of techniques, sequences of ultrafast mode locked laser pulses are used to recover pathways of interactions contributing to nonlinear susceptibilities by using a photo-acoustic modulation varying along the sequences. We show that these techniques can be viewed as a time-domain analog of the multiple frequency comb scheme.

  20. Patient training in respiratory-gated radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kini, Vijay R.; Vedam, Subrahmanya S.; Keall, Paul J.

    2003-03-31

    Respiratory gating is used to counter the effects of organ motion during radiotherapy for chest tumors. The effects of variations in patient breathing patterns during a single treatment and from day to day are unknown. We evaluated the feasibility of using patient training tools and their effect on the breathing cycle regularity and reproducibility during respiratory-gated radiotherapy. To monitor respiratory patterns, we used a component of a commercially available respiratory-gated radiotherapy system (Real Time Position Management (RPM) System, Varian Oncology Systems, Palo Alto, CA 94304). This passive marker video tracking system consists of reflective markers placed on the patient's chestmore » or abdomen, which are detected by a wall-mounted video camera. Software installed on a PC interfaced to this camera detects the marker motion digitally and records it. The marker position as a function of time serves as the motion signal that may be used to trigger imaging or treatment. The training tools used were audio prompting and visual feedback, with free breathing as a control. The audio prompting method used instructions to 'breathe in' or 'breathe out' at periodic intervals deduced from patients' own breathing patterns. In the visual feedback method, patients were shown a real-time trace of their abdominal wall motion due to breathing. Using this, they were asked to maintain a constant amplitude of motion. Motion traces of the abdominal wall were recorded for each patient for various maneuvers. Free breathing showed a variable amplitude and frequency. Audio prompting resulted in a reproducible frequency; however, the variability and the magnitude of amplitude increased. Visual feedback gave a better control over the amplitude but showed minor variations in frequency. We concluded that training improves the reproducibility of amplitude and frequency of patient breathing cycles. This may increase the accuracy of respiratory-gated radiation therapy.« less

  1. Assessment of Time and Frequency Domain Parameters of Heart Rate Variability and Interictal Cardiac Rhythm Abnormalities in Drug-naïve Patients with Idiopathic Generalized Epilepsy

    PubMed Central

    Kilinc, Ozden; Cincin, Altug; Pehlivan, Aslihan; Midi, Ipek; Kepez, Alper; Agan, Kadriye

    2016-01-01

    Background and Purpose: Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Methods: Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Results: Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Conclusions: Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures. PMID:27390676

  2. Overcoming the detection bandwidth limit in precision spectroscopy: The analytical apparatus function for a stepped frequency scan

    NASA Astrophysics Data System (ADS)

    Rohart, François

    2017-01-01

    In a previous paper [Rohart et al., Phys Rev A 2014;90(042506)], the influence of detection-bandwidth properties on observed line-shapes in precision spectroscopy was theoretically modeled for the first time using the basic model of a continuous sweeping of the laser frequency. Specific experiments confirmed general theoretical trends but also revealed several insufficiencies of the model in case of stepped frequency scans. As a consequence in as much as up-to-date experiments use step-by-step frequency-swept lasers, a new model of the influence of the detection-bandwidth is developed, including a realistic timing of signal sampling and frequency changes. Using Fourier transform techniques, the resulting time domain apparatus function gets a simple analytical form that can be easily implemented in line-shape fitting codes without any significant increase of computation durations. This new model is then considered in details for detection systems characterized by 1st and 2nd order bandwidths, underlining the importance of the ratio of detection time constant to frequency step duration, namely for the measurement of line frequencies. It also allows a straightforward analysis of corresponding systematic deviations on retrieved line frequencies and broadenings. Finally, a special attention is paid to consequences of a finite detection-bandwidth in Doppler Broadening Thermometry, namely to experimental adjustments required for a spectroscopic determination of the Boltzmann constant at the 1-ppm level of accuracy. In this respect, the interest of implementing a Butterworth 2nd order filter is emphasized.

  3. Micronucleus monitoring of a floriculturist population from western Liguria, Italy.

    PubMed

    Bolognesi, Claudia; Perrone, Emanuela; Landini, Eleonora

    2002-09-01

    A biomonitoring study was carried out to investigate whether exposure to complex pesticide mixtures in ornamental crop production represents a potential genotoxic risk. Exposed and control subjects were selected in western Liguria (Italy). The area was chosen for its intensive use of pesticides. The main crops produced were roses, mimosas, carnations and chrysanthemums, as ornamental non-edible plants, and tomato, lettuce and basil, as edible ones. The levels of micronuclei (MN) were analysed in peripheral blood lymphocytes of 107 floriculturists (92 men and 15 women) and 61 control subjects (42 men and 19 women). A statistically significant increase in binucleated cells with micronuclei (BNMN) was detected in floriculturists with respect to the control population (4.41 +/- 2.14 MN/1000 cells versus 3.04 +/- 2.14, P < 0.001). The mean number of BNMN varied as a function of sex and age. Smoking habit had no effect on MN frequency. A positive correlation between years of farming and MN frequency in peripheral blood lymphocytes was observed (r = 0.30, P = 0.02). The conditions of exposure were also associated with an increase in cytogenetic damage, with a 28% higher MN frequency in greenhouse workers compared with subjects working only outdoors in fields. Workers not using protective measures during high exposure activities showed an increase in MN frequency. Our findings suggest a potential genotoxic risk due to pesticide exposure.

  4. Prevalence of human papilloma virus infection in patients with male accessory gland infection.

    PubMed

    La Vignera, S; Vicari, E; Condorelli, R A; Franchina, C; Scalia, G; Morgia, G; Perino, A; Schillaci, R; Calogero, A E

    2015-04-01

    The frequency of human papillomavirus (HPV) infection in the semen of patients with male accessory gland infection (MAGI) was evaluated. One hundred infertile patients with MAGI were classified into group A: patients with an inflammatory MAGI (n = 48) and group B: patients with a microbial form (n = 52). Healthy age-matched fertile men (34.0 ± 4.0 years) made up the control group (n = 20). Amplification of HPV DNA was carried out by HPV-HS Bio nested polymerase chain reaction for the detection of HPV DNA sequences within the L1 ORF. Ten patients in group A (20.8%) and 15 patients in group B (28.8%) had a HPV infection; two controls (10.0%) had HPV infection. Patients with MAGI had a significantly higher frequency of HPV infection compared with controls; patients with a microbial MAGI had significantly higher frequency of HPV infection compared with patients with an inflammatory form (both P < 0.05). Patients with MAGI and HPV had a slight, but significantly lower sperm progressive motility and normal morphology compared with patients with MAGI HPV-negative (P < 0.05). Elevated frequency of HPV infection occurred in patients with MAGI, suggesting that HPV should be investigated in the diagnostic work-up of these patients. Copyright © 2014 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Detection of tiny amounts of fissile materials in large-sized containers with radioactive waste

    NASA Astrophysics Data System (ADS)

    Batyaev, V. F.; Skliarov, S. V.

    2018-01-01

    The paper is devoted to non-destructive control of tiny amounts of fissile materials in large-sized containers filled with radioactive waste (RAW). The aim of this work is to model an active neutron interrogation facility for detection of fissile ma-terials inside NZK type containers with RAW and determine the minimal detectable mass of U-235 as a function of various param-eters: matrix type, nonuniformity of container filling, neutron gen-erator parameters (flux, pulse frequency, pulse duration), meas-urement time. As a result the dependence of minimal detectable mass on fissile materials location inside container is shown. Nonu-niformity of the thermal neutron flux inside a container is the main reason of the space-heterogeneity of minimal detectable mass in-side a large-sized container. Our experiments with tiny amounts of uranium-235 (<1 g) confirm the detection of fissile materials in NZK containers by using active neutron interrogation technique.

  6. Time-Frequency Approach for Stochastic Signal Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, Ripul; Akula, Aparna; Kumar, Satish

    2011-10-20

    The detection of events in a stochastic signal has been a subject of great interest. One of the oldest signal processing technique, Fourier Transform of a signal contains information regarding frequency content, but it cannot resolve the exact onset of changes in the frequency, all temporal information is contained in the phase of the transform. On the other hand, Spectrogram is better able to resolve temporal evolution of frequency content, but has a trade-off in time resolution versus frequency resolution in accordance with the uncertainty principle. Therefore, time-frequency representations are considered for energetic characterisation of the non-stationary signals. Wigner Villemore » Distribution (WVD) is the most prominent quadratic time-frequency signal representation and used for analysing frequency variations in signals.WVD allows for instantaneous frequency estimation at each data point, for a typical temporal resolution of fractions of a second. This paper through simulations describes the way time frequency models are applied for the detection of event in a stochastic signal.« less

  7. Time-Frequency Approach for Stochastic Signal Detection

    NASA Astrophysics Data System (ADS)

    Ghosh, Ripul; Akula, Aparna; Kumar, Satish; Sardana, H. K.

    2011-10-01

    The detection of events in a stochastic signal has been a subject of great interest. One of the oldest signal processing technique, Fourier Transform of a signal contains information regarding frequency content, but it cannot resolve the exact onset of changes in the frequency, all temporal information is contained in the phase of the transform. On the other hand, Spectrogram is better able to resolve temporal evolution of frequency content, but has a trade-off in time resolution versus frequency resolution in accordance with the uncertainty principle. Therefore, time-frequency representations are considered for energetic characterisation of the non-stationary signals. Wigner Ville Distribution (WVD) is the most prominent quadratic time-frequency signal representation and used for analysing frequency variations in signals.WVD allows for instantaneous frequency estimation at each data point, for a typical temporal resolution of fractions of a second. This paper through simulations describes the way time frequency models are applied for the detection of event in a stochastic signal.

  8. Research progress of free space coherent optical communication

    NASA Astrophysics Data System (ADS)

    Tan, Zhenkun; Ke, Xizheng

    2018-02-01

    This paper mainly introduces the research progress of free space coherent optical communication in Xi'an University of Technology. In recent years, the research on the outer modulation technology of the laser, free-space-to-fiber coupling technique, the design of transmitting and receiving optical antenna, adaptive optical technology with or without wave-front sensor, automatic polarization control technology, frequency stabilization technology, heterodyne detection technology and high speed signal processing technology. Based on the above related research, the digital signal modulation, transmission, detection and data recovery are realized by the heterodyne detection technology in the free space optical communication system, and finally the function of smooth viewing high-definition video is realized.

  9. Visual Search Performance in the Autism Spectrum II: The Radial Frequency Search Task with Additional Segmentation Cues

    ERIC Educational Resources Information Center

    Almeida, Renita A.; Dickinson, J. Edwin; Maybery, Murray T.; Badcock, Johanna C.; Badcock, David R.

    2010-01-01

    The Embedded Figures Test (EFT) requires detecting a shape within a complex background and individuals with autism or high Autism-spectrum Quotient (AQ) scores are faster and more accurate on this task than controls. This research aimed to uncover the visual processes producing this difference. Previously we developed a search task using radial…

  10. Polarization feedback laser stabilization

    DOEpatents

    Esherick, P.; Owyoung, A.

    1987-09-28

    A system for locking two Nd:YAG laser oscillators includes an optical path for feeding the output of one laser into the other with different polarizations. Elliptical polarization is incorporated into the optical path so that the change in polarization that occurs when the frequencies coincide may be detected to provide a feedback signal to control one laser relative to the other. 4 figs.

  11. Fieldable Fourier transform spectrometer

    NASA Astrophysics Data System (ADS)

    Hatchell, Brian K.; Harper, Warren W.; Schultz, John F.

    2004-10-01

    The infrared sensors group at the Pacific Northwest National Laboratory (PNNL) is focused on the science and technology of remote and in-situ chemical sensors for detecting proliferation and countering terrorism. To support these vital missions, PNNL is developing frequency-modulation techniques for remote probing over long optical paths by means of differential-absorption light detecting and ranging (LIDAR). This technique can easily monitor large areas, or volumes, that could only be accomplished with a large network of point sensors. Recently, PNNL began development of a rugged frequency-modulation differential-abosrption LIDAR (FM-DIAL) system to conduct field experiments. To provide environmentla protection for the system and facilitate field deployments and operations, a large, well insulated, temperature controlled trailer was specified and acquired. The trailer was outfitted with a shock-mounted optical bench, an electronics rack, a liquid nitrogen Dewar, and a power generator. A computer-controlled gimbal-mounted mirror was added to allow the telescope beam to be accurately pointed in both the vertical and horizontal plane. This turned out to be the most complicated addition, and is described in detail. This paper provides an overview of the FM-DIAL system and illustrates innovative solutions developed to overcome several alignment and stability issues encountered in the field.

  12. Algorithm based on the short-term Rényi entropy and IF estimation for noisy EEG signals analysis.

    PubMed

    Lerga, Jonatan; Saulig, Nicoletta; Mozetič, Vladimir

    2017-01-01

    Stochastic electroencephalogram (EEG) signals are known to be nonstationary and often multicomponential. Detecting and extracting their components may help clinicians to localize brain neurological dysfunctionalities for patients with motor control disorders due to the fact that movement-related cortical activities are reflected in spectral EEG changes. A new algorithm for EEG signal components detection from its time-frequency distribution (TFD) has been proposed in this paper. The algorithm utilizes the modification of the Rényi entropy-based technique for number of components estimation, called short-term Rényi entropy (STRE), and upgraded by an iterative algorithm which was shown to enhance existing approaches. Combined with instantaneous frequency (IF) estimation, the proposed method was applied to EEG signal analysis both in noise-free and noisy environments for limb movements EEG signals, and was shown to be an efficient technique providing spectral description of brain activities at each electrode location up to moderate additive noise levels. Furthermore, the obtained information concerning the number of EEG signal components and their IFs show potentials to enhance diagnostics and treatment of neurological disorders for patients with motor control illnesses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    PubMed

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  14. Low-frequency drug-resistant HIV-1 and risk of virological failure to first-line NNRTI-based ART: a multicohort European case-control study using centralized ultrasensitive 454 pyrosequencing.

    PubMed

    Cozzi-Lepri, Alessandro; Noguera-Julian, Marc; Di Giallonardo, Francesca; Schuurman, Rob; Däumer, Martin; Aitken, Sue; Ceccherini-Silberstein, Francesca; D'Arminio Monforte, Antonella; Geretti, Anna Maria; Booth, Clare L; Kaiser, Rolf; Michalik, Claudia; Jansen, Klaus; Masquelier, Bernard; Bellecave, Pantxika; Kouyos, Roger D; Castro, Erika; Furrer, Hansjakob; Schultze, Anna; Günthard, Huldrych F; Brun-Vezinet, Francoise; Paredes, Roger; Metzner, Karin J

    2015-03-01

    It is still debated if pre-existing minority drug-resistant HIV-1 variants (MVs) affect the virological outcomes of first-line NNRTI-containing ART. This Europe-wide case-control study included ART-naive subjects infected with drug-susceptible HIV-1 as revealed by population sequencing, who achieved virological suppression on first-line ART including one NNRTI. Cases experienced virological failure and controls were subjects from the same cohort whose viraemia remained suppressed at a matched time since initiation of ART. Blinded, centralized 454 pyrosequencing with parallel bioinformatic analysis in two laboratories was used to identify MVs in the 1%-25% frequency range. ORs of virological failure according to MV detection were estimated by logistic regression. Two hundred and sixty samples (76 cases and 184 controls), mostly subtype B (73.5%), were used for the analysis. Identical MVs were detected in the two laboratories. 31.6% of cases and 16.8% of controls harboured pre-existing MVs. Detection of at least one MV versus no MVs was associated with an increased risk of virological failure (OR = 2.75, 95% CI = 1.35-5.60, P = 0.005); similar associations were observed for at least one MV versus no NRTI MVs (OR = 2.27, 95% CI = 0.76-6.77, P = 0.140) and at least one MV versus no NNRTI MVs (OR = 2.41, 95% CI = 1.12-5.18, P = 0.024). A dose-effect relationship between virological failure and mutational load was found. Pre-existing MVs more than double the risk of virological failure to first-line NNRTI-based ART. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.

  15. Sex-dependent alterations in resting-state cerebral blood flow, amplitude of low-frequency fluctuations and their coupling relationship in schizophrenia.

    PubMed

    Ma, Xiaomei; Wang, Di; Zhou, Yujing; Zhuo, Chuanjun; Qin, Wen; Zhu, Jiajia; Yu, Chunshui

    2016-04-01

    We aimed to investigate sex-dependent alterations in resting-state relative cerebral blood flow, amplitude of low-frequency fluctuations and relative cerebral blood flow-amplitude of low-frequency fluctuations coupling in patients with schizophrenia. Resting-state functional magnetic resonance imaging and three-dimensional pseudo-continuous arterial spin labeling imaging were performed to obtain resting-state amplitude of low-frequency fluctuations and relative cerebral blood flow in 95 schizophrenia patients and 99 healthy controls. Sex differences in relative cerebral blood flow and amplitude of low-frequency fluctuations were compared in both groups. Diagnostic group differences in relative cerebral blood flow, amplitude of low-frequency fluctuations and relative cerebral blood flow-amplitude of low-frequency fluctuations coupling were compared in male and female subjects, respectively. In both healthy controls and schizophrenia patients, the males had higher relative cerebral blood flow in anterior brain regions and lower relative cerebral blood flow in posterior brain regions than did the females. Compared with multiple regions exhibiting sex differences in relative cerebral blood flow, only the left middle frontal gyrus had a significant sex difference in amplitude of low-frequency fluctuations. In the females, schizophrenia patients exhibited increased relative cerebral blood flow and amplitude of low-frequency fluctuations in the basal ganglia, thalamus and hippocampus and reduced relative cerebral blood flow and amplitude of low-frequency fluctuations in the frontal, parietal and occipital regions compared with those of healthy controls. However, there were fewer brain regions with diagnostic group differences in the males than in the females. Brain regions with diagnostic group differences in relative cerebral blood flow and amplitude of low-frequency fluctuations only partially overlapped. Only the female patients exhibited increased relative cerebral blood flow-amplitude of low-frequency fluctuations couplings compared with those of healthy females. The alterations in the relative cerebral blood flow and amplitude of low-frequency fluctuations in schizophrenia are sex-specific, which should be considered in future neuroimaging studies. The relative cerebral blood flow and amplitude of low-frequency fluctuations have different sensitivity in detecting changes in neuronal activity in schizophrenia and can provide complementary information. © The Royal Australian and New Zealand College of Psychiatrists 2015.

  16. Phase-locked loop based on nanoelectromechanical resonant-body field effect transistor

    NASA Astrophysics Data System (ADS)

    Bartsch, S. T.; Rusu, A.; Ionescu, A. M.

    2012-10-01

    We demonstrate the room-temperature operation of a silicon nanoelectromechanical resonant-body field effect transistor (RB-FET) embedded into phase-locked loop (PLL). The very-high frequency resonator uses on-chip electrostatic actuation and transistor-based displacement detection. The heterodyne frequency down-conversion based on resistive FET mixing provides a loop feedback signal with high signal-to-noise ratio. We identify key parameters for PLL operation, and analyze the performance of the RB-FET at the system level. Used as resonant mass detector, the experimental frequency stability in the ppm-range translates into sub atto-gram (10-18 g) sensitivity in high vacuum. The feedback and control system are generic and may be extended to other mechanical resonators with transistor properties, such as graphene membranes and carbon nanotubes.

  17. Development of a long-gauge vibration sensor

    NASA Astrophysics Data System (ADS)

    Kung, Peter; Comanici, Maria I.; Li, Qian; Zhang, Yiwei

    2015-03-01

    We have recently found that a long length of fiber of up to 1 km terminated with an in-fiber cavity structure can detect vibrations over a frequency range from 5 Hz to 2 kHz. We want to determine whether the sensor (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to maintenance cost. The sensor may also help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that requires the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Acoustic vibration monitoring may need sensing at even higher frequencies (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large re-enforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed longgauge vibration sensor depends on packaging.

  18. Shapes of Magnetically Controlled Electron Density Structures in the Dayside Martian Ionosphere

    NASA Astrophysics Data System (ADS)

    Diéval, C.; Kopf, A. J.; Wild, J. A.

    2018-05-01

    Nonhorizontal localized electron density structures associated with regions of near-radial crustal magnetic fields are routinely detected via radar oblique echoes on the dayside of Mars with the ionospheric sounding mode of the Mars Advanced Radar for Subsurface and Ionospheric Sounding (MARSIS) radar onboard Mars Express. Previous studies mostly investigated these structures at a fixed plasma frequency and assumed that the larger apparent altitude of the structures compared to the normal surrounding ionosphere implied that they are bulges. However, the signal is subjected to dispersion when it propagates through the plasma, so interpretations based on the apparent altitude should be treated with caution. We go further by investigating the frequency dependence (i.e., the altitude dependence) of the shape of 48 density structure events, using time series of MARSIS electron density profiles corrected for signal dispersion. Four possible simplest shapes are detected in these time series, which can give oblique echoes: bulges, dips, downhill slopes, and uphill slopes. The altitude differences between the density structures and their edges are, in absolute value, larger at low frequency (high altitude) than at high frequency (low altitude), going from a few tens of kilometers to a few kilometers as frequency increases. Bulges dominate in numbers in most of the frequency range. Finally, the geographical extension of the density structures covers a wide range of crustal magnetic fields orientations, with near-vertical fields toward their center and near-horizontal fields toward their edges, as expected. Transport processes are suggested to be a key driver for these density structures.

  19. Segmentation of the Thalamus Based on BOLD Frequencies Affected in Temporal Lobe Epilepsy

    PubMed Central

    Morgan, Victoria L.; Rogers, Baxter P.; Abou-Khalil, Bassel

    2015-01-01

    Objective Temporal lobe epilepsy is associated with functional changes throughout the brain, particularly including a putative seizure propagation network involving the hippocampus, insula and thalamus. We identified a specified frequency range where functional connectivity in this network was related to duration of disease. Then, to identify specific thalamic nuclei involved in seizure propagation, we determined the subregions of the thalamus that have increased resting functional oscillations in this frequency range. Methods Resting-state functional MRI (fMRI) was acquired from twenty unilateral TLE (14 right, 6 left) patients and twenty healthy controls who were each age and gender matched to a specific patient. Wavelet based functional MRI connectivity mapping across the network was computed at each frequency to determine those frequencies where connectivity significantly decreases with duration of disease consistent with impairment due to repeated seizures. The voxel-wise power of the spontaneous blood oxygenation fluctuations of this frequency band was computed in the thalamus of each subject. Results Functional connectivity was impaired in the proposed seizure propagation network over a specific range (0.0067–0.013 Hz and 0.024–0.032 Hz) of blood oxygenation oscillations. Increased power in this frequency band (<0.032 Hz) was detected bilaterally in the pulvinar and anterior nucleus of the thalamus of healthy controls, and was increased over the ipsilateral thalamus compared to the contralateral thalamus in TLE. Significance This study identified frequencies of impaired connectivity in a TLE seizure propagation network and used them to localize the anterior nucleus and pulvinar of the thalamus as subregions most susceptible to TLE seizures. Further examinations of these frequencies in healthy and TLE subjects may provide unique information relating to the mechanism of seizure propagation and potential treatment using electrical stimulation. PMID:26360535

  20. CNV analysis in 169 patients with bladder exstrophy-epispadias complex.

    PubMed

    von Lowtzow, Catharina; Hofmann, Andrea; Zhang, Rong; Marsch, Florian; Ebert, Anne-Karoline; Rösch, Wolfgang; Stein, Raimund; Boemers, Thomas M; Hirsch, Karin; Marcelis, Carlo; Feitz, Wouter F J; Brusco, Alfredo; Migone, Nicola; Di Grazia, Massimo; Moebus, Susanne; Nöthen, Markus M; Reutter, Heiko; Ludwig, Michael; Draaken, Markus

    2016-04-30

    The bladder exstrophy-epispadias complex (BEEC) represents the severe end of the congenital uro-rectal malformation spectrum. Initial studies have implicated rare copy number variations (CNVs), including recurrent duplications of chromosomal region 22q11.21, in BEEC etiology. To detect further CNVs, array analysis was performed in 169 BEEC patients. Prior to inclusion, 22q11.21 duplications were excluded using multiplex ligation-dependent probe amplification. Following the application of stringent filter criteria, seven rare CNVs were identified: n = 4, not present in 1307 in-house controls; n = 3, frequency of <0.002 in controls. These CNVs ranged from 1 to 6.08 Mb in size. To identify smaller CNVs, relaxed filter criteria used in the detection of previously reported BEEC associated chromosomal regions were applied. This resulted in the identification of six additional rare CNVs: n = 4, not present in 1307 in-house controls; n = 2, frequency <0.0008 in controls. These CNVs ranged from 0.03-0.08 Mb in size. For 10 of these 13 CNVs, confirmation and segregation analyses were performed (5 of maternal origin; 5 of paternal origin). Interestingly, one female with classic bladder extrophy carried a 1.18 Mb duplication of 22q11.1, a chromosomal region that is associated with cat eye syndrome. A number of rare CNVs were identified in BEEC patients, and these represent candidates for further evaluation. Rare inherited CNVs may constitute modifiers of, or contributors to, multifactorial BEEC phenotypes.

  1. Visual Evoked Cortical Potential (VECP) Elicited by Sinusoidal Gratings Controlled by Pseudo-Random Stimulation

    PubMed Central

    Araújo, Carolina S.; Souza, Givago S.; Gomes, Bruno D.; Silveira, Luiz Carlos L.

    2013-01-01

    The contributions of contrast detection mechanisms to the visual cortical evoked potential (VECP) have been investigated studying the contrast-response and spatial frequency-response functions. Previously, the use of m-sequences for stimulus control has been almost restricted to multifocal electrophysiology stimulation and, in some aspects, it substantially differs from conventional VECPs. Single stimulation with spatial contrast temporally controlled by m-sequences has not been extensively tested or compared to multifocal techniques. Our purpose was to evaluate the influence of spatial frequency and contrast of sinusoidal gratings on the VECP elicited by pseudo-random stimulation. Nine normal subjects were stimulated by achromatic sinusoidal gratings driven by pseudo random binary m-sequence at seven spatial frequencies (0.4–10 cpd) and three stimulus sizes (4°, 8°, and 16° of visual angle). At 8° subtence, six contrast levels were used (3.12–99%). The first order kernel (K1) did not provide a consistent measurable signal across spatial frequencies and contrasts that were tested–signal was very small or absent–while the second order kernel first (K2.1) and second (K2.2) slices exhibited reliable responses for the stimulus range. The main differences between results obtained with the K2.1 and K2.2 were in the contrast gain as measured in the amplitude versus contrast and amplitude versus spatial frequency functions. The results indicated that K2.1 was dominated by M-pathway, but for some stimulus condition some P-pathway contribution could be found, while the second slice reflected the P-pathway contribution. The present work extended previous findings of the visual pathways contribution to VECP elicited by pseudorandom stimulation for a wider range of spatial frequencies. PMID:23940546

  2. Fast Interrogation of Fiber Bragg Gratings with Electro-Optical Dual Optical Frequency Combs

    PubMed Central

    Posada-Roman, Julio E.; Garcia-Souto, Jose A.; Poiana, Dragos A.; Acedo, Pablo

    2016-01-01

    Optical frequency combs (OFC) generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG) sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz). Measurements of ultrasounds (40 kHz and 120 kHz) are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal. PMID:27898043

  3. Fast Interrogation of Fiber Bragg Gratings with Electro-Optical Dual Optical Frequency Combs.

    PubMed

    Posada-Roman, Julio E; Garcia-Souto, Jose A; Poiana, Dragos A; Acedo, Pablo

    2016-11-26

    Optical frequency combs (OFC) generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG) sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz). Measurements of ultrasounds (40 kHz and 120 kHz) are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal.

  4. [Correlation of HLA-A, B, DRB1 genes with leukemia].

    PubMed

    Du, Ying; Liang, Xiao-lan; Li, Qian; Wu, Wen-jie; Liu, Jian; Sun, Le-jing; Qiu, Lu-gui

    2013-04-01

    This study was aimed to investigate the correlation between HLA gene distribution and allele frequency of the patients with leukemia. PCR-SSP technique was used to detect the HLA genotype of 2994 umbilical cord blood units from healthy newborns (as control), the detecting result of which was compared with HLA genotypes of 1246 patients with leukemia searched in our cord blood bank. The differences between two groups were compared and analyzed. The results indicated that as compared with the control group, the allele frequencies of HLA-B*56 (0.56%), B*70 (0.24%) obviously increased (RR = 2.2546, 6.2598, χ(2) = 5, 5.98, P < 0.05), while the allele frequencies of HLA-A*03 (3.45%), A*30 (4.86%), B*13 (8.75%), B44* (3.25%), B61* (5.70%), DRB1*07 (8.23%), DRB1*15 (14.21%) obviously decreased in patients with leukemia (RR = 0.5889, 0.7187, 0.7359, 0.5713, 0.7127, 0.6242, 0.7976, χ(2) = 19.23, 9.82, 14.33, 20.48, 11.99, 33.21, 11.56, P < 0.01). It is concluded that HLA-B*56, B*70 alleles seem to be characterized by the genetic susceptibility to leukemia and may be served as risk markers for leukemia occurrence, while the HLA-A*03, A*30, B*13, B*44, B*61, DRB1*07, DRB1*15 can be considered as genetic indicators for resistance of leukemia.

  5. Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoke, Anderson; Nelson, Austin; Miller, Brian

    As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly ormore » indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.« less

  6. [Detection of endotoxins of Gram-negative bacteria on the basis of electromagnetic radiation frequency spectrum].

    PubMed

    Likhoded, V G; Kuleshova, N V; Sergieva, N V; Konev, Iu V; Trubnikova, I A; Sudzhian, E V

    2007-01-01

    Method of Gram-negative bacteria endotoxins detection on the basis of their own spectrum of electromagnetic radiation frequency was developed. Frequency spectrum typical for chemotype Re glycolipid, which is a part of lypopolysaccharides in the majority of Gram-negative bacteria, was used. Two devices--"Mini- Expert-DT" (manufactured by IMEDIS, Moscow) and "Bicom" (manufactured by Regumed, Germany)--were used as generators of electromagnetic radiation. Detection of endotoxin using these devices was performed by electropuncture vegetative resonance test. Immunoenzyme reaction with antibodies to chemotype Re glycolipid was used during analysis of preparations for assessment of resonance-frequency method specificity. The study showed that resonance-frequency method can detect lypopolysaccharides of different enterobacteria in quantities up to 0.1 pg as well as bacteria which contain lypopolysaccharides. At the same time, this method does not detect such bacteria as Staphylococcus aureus, Bifidobacterium spp., Lactobacillus spp., and Candida albicans. The method does not require preliminary processing of blood samples and can be used for diagnostics of endotoxinemia, and detection of endotoxins in blood samples or injection solutions.

  7. Post-Control Surveillance of Triatoma infestans and Triatoma sordida with Chemically-Baited Sticky Traps

    PubMed Central

    Acosta, Nidia; López, Elsa; González, Nilsa; Zerba, Eduardo; Tarelli, Guillermo; Masuh, Héctor

    2012-01-01

    Background Chagas disease prevention critically depends on keeping houses free of triatomine vectors. Insecticide spraying is very effective, but re-infestation of treated dwellings is commonplace. Early detection-elimination of re-infestation foci is key to long-term control; however, all available vector-detection methods have low sensitivity. Chemically-baited traps are widely used in vector and pest control-surveillance systems; here, we test this approach for Triatoma spp. detection under field conditions in the Gran Chaco. Methodology/Principal Findings Using a repeated-sampling approach and logistic models that explicitly take detection failures into account, we simultaneously estimate vector occurrence and detection probabilities. We then model detection probabilities (conditioned on vector occurrence) as a function of trapping system to measure the effect of chemical baits. We find a positive effect of baits after three (odds ratio [OR] 5.10; 95% confidence interval [CI95] 2.59–10.04) and six months (OR 2.20, CI95 1.04–4.65). Detection probabilities are estimated at p≈0.40–0.50 for baited and at just p≈0.15 for control traps. Bait effect is very strong on T. infestans (three-month assessment: OR 12.30, CI95 4.44–34.10; p≈0.64), whereas T. sordida is captured with similar frequency in baited and unbaited traps. Conclusions/Significance Chemically-baited traps hold promise for T. infestans surveillance; the sensitivity of the system at detecting small re-infestation foci rises from 12.5% to 63.6% when traps are baited with semiochemicals. Accounting for imperfect detection, infestation is estimated at 26% (CI95 16–40) after three and 20% (CI95 11–34) after six months. In the same assessments, traps detected infestation in 14% and 8.5% of dwellings, whereas timed manual searches (the standard approach) did so in just 1.4% of dwellings only in the first survey. Since infestation rates are the main indicator used for decision-making in control programs, the approach we present may help improve T. infestans surveillance and control program management. PMID:23029583

  8. Interactions between amplitude modulation and frequency modulation processing: Effects of age and hearing loss.

    PubMed

    Paraouty, Nihaad; Ewert, Stephan D; Wallaert, Nicolas; Lorenzi, Christian

    2016-07-01

    Frequency modulation (FM) and amplitude modulation (AM) detection thresholds were measured for a 500-Hz carrier frequency and a 5-Hz modulation rate. For AM detection, FM at the same rate as the AM was superimposed with varying FM depth. For FM detection, AM at the same rate was superimposed with varying AM depth. The target stimuli always contained both amplitude and frequency modulations, while the standard stimuli only contained the interfering modulation. Young and older normal-hearing listeners, as well as older listeners with mild-to-moderate sensorineural hearing loss were tested. For all groups, AM and FM detection thresholds were degraded in the presence of the interfering modulation. AM detection with and without interfering FM was hardly affected by either age or hearing loss. While aging had an overall detrimental effect on FM detection with and without interfering AM, there was a trend that hearing loss further impaired FM detection in the presence of AM. Several models using optimal combination of temporal-envelope cues at the outputs of off-frequency filters were tested. The interfering effects could only be predicted for hearing-impaired listeners. This indirectly supports the idea that, in addition to envelope cues resulting from FM-to-AM conversion, normal-hearing listeners use temporal fine-structure cues for FM detection.

  9. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers

    NASA Astrophysics Data System (ADS)

    Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li

    2016-04-01

    Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r 2  =  0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.

  10. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.

    PubMed

    Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li

    2016-04-07

    Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r (2)  =  0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.

  11. Efficient Terahertz detection in black-phosphorus nano-transistors with selective and controllable plasma-wave, bolometric and thermoelectric response

    PubMed Central

    Viti, Leonardo; Hu, Jin; Coquillat, Dominique; Politano, Antonio; Knap, Wojciech; Vitiello, Miriam S.

    2016-01-01

    The ability to convert light into an electrical signal with high efficiencies and controllable dynamics, is a major need in photonics and optoelectronics. In the Terahertz (THz) frequency range, with its exceptional application possibilities in high data rate wireless communications, security, night-vision, biomedical or video-imaging and gas sensing, detection technologies providing efficiency and sensitivity performances that can be “engineered” from scratch, remain elusive. Here, by exploiting the inherent electrical and thermal in-plane anisotropy of a flexible thin flake of black-phosphorus (BP), we devise plasma-wave, thermoelectric and bolometric nano-detectors with a selective, switchable and controllable operating mechanism. All devices operates at room-temperature and are integrated on-chip with planar nanoantennas, which provide remarkable efficiencies through light-harvesting in the strongly sub-wavelength device channel. The achieved selective detection (∼5–8 V/W responsivity) and sensitivity performances (signal-to-noise ratio of 500), are here exploited to demonstrate the first concrete application of a phosphorus-based active THz device, for pharmaceutical and quality control imaging of macroscopic samples, in real-time and in a realistic setting. PMID:26847823

  12. Musicians Are Better than Non-musicians in Frequency Change Detection: Behavioral and Electrophysiological Evidence

    PubMed Central

    Liang, Chun; Earl, Brian; Thompson, Ivy; Whitaker, Kayla; Cahn, Steven; Xiang, Jing; Fu, Qian-Jie; Zhang, Fawen

    2016-01-01

    Objective: The objectives of this study were: (1) to determine if musicians have a better ability to detect frequency changes under quiet and noisy conditions; (2) to use the acoustic change complex (ACC), a type of electroencephalographic (EEG) response, to understand the neural substrates of musician vs. non-musician difference in frequency change detection abilities. Methods: Twenty-four young normal hearing listeners (12 musicians and 12 non-musicians) participated. All participants underwent psychoacoustic frequency detection tests with three types of stimuli: tones (base frequency at 160 Hz) containing frequency changes (Stim 1), tones containing frequency changes masked by low-level noise (Stim 2), and tones containing frequency changes masked by high-level noise (Stim 3). The EEG data were recorded using tones (base frequency at 160 and 1200 Hz, respectively) containing different magnitudes of frequency changes (0, 5, and 50% changes, respectively). The late-latency evoked potential evoked by the onset of the tones (onset LAEP or N1-P2 complex) and that evoked by the frequency change contained in the tone (the acoustic change complex or ACC or N1′-P2′ complex) were analyzed. Results: Musicians significantly outperformed non-musicians in all stimulus conditions. The ACC and onset LAEP showed similarities and differences. Increasing the magnitude of frequency change resulted in increased ACC amplitudes. ACC measures were found to be significantly different between musicians (larger P2′ amplitude) and non-musicians for the base frequency of 160 Hz but not 1200 Hz. Although the peak amplitude in the onset LAEP appeared to be larger and latency shorter in musicians than in non-musicians, the difference did not reach statistical significance. The amplitude of the onset LAEP is significantly correlated with that of the ACC for the base frequency of 160 Hz. Conclusion: The present study demonstrated that musicians do perform better than non-musicians in detecting frequency changes in quiet and noisy conditions. The ACC and onset LAEP may involve different but overlapping neural mechanisms. Significance: This is the first study using the ACC to examine music-training effects. The ACC measures provide an objective tool for documenting musical training effects on frequency detection. PMID:27826221

  13. Development of a compact laser-based single photon ionization time-of-flight mass spectrometer

    NASA Astrophysics Data System (ADS)

    Tonokura, Kenichi; Kanno, Nozomu; Yamamoto, Yukio; Yamada, Hiroyuki

    2010-02-01

    We have developed a compact, laser-based, single photon ionization time-of-flight mass spectrometer (SPI-TOF-MS) for on-line monitoring of trace organic species. To obtain the mass spectrum, we use a nearly fragmentation-free SPI technique with 10.5 eV (118 nm) vacuum ultraviolet laser pulses generated by frequency tripling of the third harmonic of an Nd:YAG laser. The instrument can be operated in a linear TOF-MS mode or a reflectron TOF-MS mode in the coaxial design. We designed ion optics to optimize detection sensitivity and mass resolution. For data acquisition, the instrument is controlled using LabVIEW control software. The total power requirement for the vacuum unit, control electronics unit, ion optics, and detection system is approximately 100 W. We achieve a detection limit of parts per billion by volume (ppbv) for on-line trace analysis of several organic compounds. A mass resolution of 800 at about 100 amu is obtained for reflectron TOF-MS mode in a 0.35 m long instrument. The application of on-line monitoring of diesel engine exhaust was demonstrated.

  14. [Activation of peripheral T lymphocytes in children with epilepsy and production of cytokines].

    PubMed

    Yang, Jie; Hu, Chongkang; Jiang, Xun

    2016-09-01

    Objective To study the state of peripheral T lymphocytes and cytokine levels in children with epilepsy. Methods Twenty children with epilepsy and 20 healthy age-matched children were recruited and their peripheral blood was collected. The activation of T lymphocytes was evaluated by detecting the expressions of CD25, CD69 and cytotoxic T lymphocyte-assicated antigen 4 (CTLA4). The function of T lymphocytes was evaluated by detecting the expressions of interferon γ (IFN-γ), tumor necrosis factor α (TNF-α), IL-17A and IL-6. The activation of regulatory T cells (Tregs) was evaluated by detecting the expression of IL-10. Results Children with epilepsy had higher expressions of CD25, CD69 and CTLA-4 in T lymphocytes than the controls did. The expressions of IFN-γ, TNF-α, IL-17A and IL-6 in T lymphocytes of children with epilepsy were higher than those of the controls. Frequency of Tregs producing IL-10 was higher in children with epilepsy as compared with the controls. Conclusion Peripheral T lymphocytes of children with epilepsy are activated and produce cytokines.

  15. Mutual Information in Frequency and Its Application to Measure Cross-Frequency Coupling in Epilepsy

    NASA Astrophysics Data System (ADS)

    Malladi, Rakesh; Johnson, Don H.; Kalamangalam, Giridhar P.; Tandon, Nitin; Aazhang, Behnaam

    2018-06-01

    We define a metric, mutual information in frequency (MI-in-frequency), to detect and quantify the statistical dependence between different frequency components in the data, referred to as cross-frequency coupling and apply it to electrophysiological recordings from the brain to infer cross-frequency coupling. The current metrics used to quantify the cross-frequency coupling in neuroscience cannot detect if two frequency components in non-Gaussian brain recordings are statistically independent or not. Our MI-in-frequency metric, based on Shannon's mutual information between the Cramer's representation of stochastic processes, overcomes this shortcoming and can detect statistical dependence in frequency between non-Gaussian signals. We then describe two data-driven estimators of MI-in-frequency: one based on kernel density estimation and the other based on the nearest neighbor algorithm and validate their performance on simulated data. We then use MI-in-frequency to estimate mutual information between two data streams that are dependent across time, without making any parametric model assumptions. Finally, we use the MI-in- frequency metric to investigate the cross-frequency coupling in seizure onset zone from electrocorticographic recordings during seizures. The inferred cross-frequency coupling characteristics are essential to optimize the spatial and spectral parameters of electrical stimulation based treatments of epilepsy.

  16. Decreased mutation frequencies among immunoglobulin G variable region genes during viremic HIV-1 infection.

    PubMed

    Bowers, Elisabeth; Scamurra, Ronald W; Asrani, Anil; Beniguel, Lydie; MaWhinney, Samantha; Keays, Kathryne M; Thurn, Joseph R; Janoff, Edward N

    2014-01-01

    HIV-1 infection is complicated by high rates of opportunistic infections against which specific antibodies contribute to immune defense. Antibody function depends on somatic hypermutation (SHM) of variable regions of immunoglobulin heavy chain genes (VH-D-J). We characterized the frequency of SHM in expressed IgG mRNA immunoglobulin transcripts from control and HIV-1-infected patients. We compared utilization of genes in the most prominent VH family (VH3) and mutation frequencies and patterns of cDNA from VH3-IgG genes from 10 seronegative control subjects and 21 patients with HIV-1 infection (6 without and 15 patients with detectable plasma viremia). Unique IgG VH3 family cDNA sequences (n = 1,565) were PCR amplified, cloned, and sequenced from blood. Sequences were analyzed using online (Vbase) and in-house immunoglobulin alignment resources. Mutation frequencies in the antigen-binding hypervariable complementarity determining regions (CDR1/2) of IgG class-switched B cells were lower among viremic HIV-1-infected patients vs. controls for nucleotides (CDR1/2: 10±5% vs. 13.5±6%, p = 0.03) and amino acids (CDR: 20%±10 vs. 25%±12, p = 0.02) and in structural framework regions. Mutation patterns were similar among groups. The most common VH3 gene, VH3-23, was utilized less frequently among viremic HIV-1-infected patients (p = 0.03), and overall, mutation frequencies were decreased in nearly all VH3 genes compared with controls. B cells from HIV-1-infected patients show decreased mutation frequencies, especially in antigen-binding VH3 CDR genes, and selective defects in gene utilization. Similar mutation patterns suggest defects in the quantity, but not quality, of mutator activity. Lower levels of SHM in IgG class-switched B cells from HIV-1-infected patients may contribute to the increased risk of opportunistic infections and impaired humoral responses to preventative vaccines.

  17. Stimulus change detection in phasic auditory units in the frog midbrain: frequency and ear specific adaptation.

    PubMed

    Ponnath, Abhilash; Hoke, Kim L; Farris, Hamilton E

    2013-04-01

    Neural adaptation, a reduction in the response to a maintained stimulus, is an important mechanism for detecting stimulus change. Contributing to change detection is the fact that adaptation is often stimulus specific: adaptation to a particular stimulus reduces excitability to a specific subset of stimuli, while the ability to respond to other stimuli is unaffected. Phasic cells (e.g., cells responding to stimulus onset) are good candidates for detecting the most rapid changes in natural auditory scenes, as they exhibit fast and complete adaptation to an initial stimulus presentation. We made recordings of single phasic auditory units in the frog midbrain to determine if adaptation was specific to stimulus frequency and ear of input. In response to an instantaneous frequency step in a tone, 28% of phasic cells exhibited frequency specific adaptation based on a relative frequency change (delta-f=±16%). Frequency specific adaptation was not limited to frequency steps, however, as adaptation was also overcome during continuous frequency modulated stimuli and in response to spectral transients interrupting tones. The results suggest that adaptation is separated for peripheral (e.g., frequency) channels. This was tested directly using dichotic stimuli. In 45% of binaural phasic units, adaptation was ear specific: adaptation to stimulation of one ear did not affect responses to stimulation of the other ear. Thus, adaptation exhibited specificity for stimulus frequency and lateralization at the level of the midbrain. This mechanism could be employed to detect rapid stimulus change within and between sound sources in complex acoustic environments.

  18. Stimulus change detection in phasic auditory units in the frog midbrain: frequency and ear specific adaptation

    PubMed Central

    Ponnath, Abhilash; Hoke, Kim L.

    2013-01-01

    Neural adaptation, a reduction in the response to a maintained stimulus, is an important mechanism for detecting stimulus change. Contributing to change detection is the fact that adaptation is often stimulus specific: adaptation to a particular stimulus reduces excitability to a specific subset of stimuli, while the ability to respond to other stimuli is unaffected. Phasic cells (e.g., cells responding to stimulus onset) are good candidates for detecting the most rapid changes in natural auditory scenes, as they exhibit fast and complete adaptation to an initial stimulus presentation. We made recordings of single phasic auditory units in the frog midbrain to determine if adaptation was specific to stimulus frequency and ear of input. In response to an instantaneous frequency step in a tone, 28 % of phasic cells exhibited frequency specific adaptation based on a relative frequency change (delta-f = ±16 %). Frequency specific adaptation was not limited to frequency steps, however, as adaptation was also overcome during continuous frequency modulated stimuli and in response to spectral transients interrupting tones. The results suggest that adaptation is separated for peripheral (e.g., frequency) channels. This was tested directly using dichotic stimuli. In 45 % of binaural phasic units, adaptation was ear specific: adaptation to stimulation of one ear did not affect responses to stimulation of the other ear. Thus, adaptation exhibited specificity for stimulus frequency and lateralization at the level of the midbrain. This mechanism could be employed to detect rapid stimulus change within and between sound sources in complex acoustic environments. PMID:23344947

  19. An interferometric fiber optic hydrophone with large upper limit of dynamic range

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Kan, Baoxi; Zheng, Baichao; Wang, Xuefeng; Zhang, Haiyan; Hao, Liangbin; Wang, Hailiang; Hou, Zhenxing; Yu, Wenpeng

    2017-10-01

    Interferometric fiber optic hydrophone based on heterodyne detection is used to measure the missile dropping point in the sea. The signal caused by the missile dropping in the water will be too large to be detected, so it is necessary to boost the upper limit of dynamic range (ULODR) of fiber optic hydrophone. In this article we analysis the factors which influence the ULODR of fiber optic hydrophone based on heterodyne detection, the ULODR is decided by the sampling frequency fsam and the heterodyne frequency Δf. The sampling frequency and the heterodyne frequency should be satisfied with the Nyquist sampling theorem which fsam will be two times larger than Δf, in this condition the ULODR is depended on the heterodyne frequency. In order to enlarge the ULODR, the Nyquist sampling theorem was broken, and we proposed a fiber optic hydrophone which the heterodyne frequency is larger than the sampling frequency. Both the simulation and experiment were done in this paper, the consequences are similar: When the sampling frequency is 100kHz, the ULODR of large heterodyne frequency fiber optic hydrophone is 2.6 times larger than that of the small heterodyne frequency fiber optic hydrophone. As the heterodyne frequency is larger than the sampling frequency, the ULODR is depended on the sampling frequency. If the sampling frequency was set at 2MHz, the ULODR of fiber optic hydrophone based on heterodyne detection will be boosted to 1000rad at 1kHz, and this large heterodyne fiber optic hydrophone can be applied to locate the drop position of the missile in the sea.

  20. Improved MIMO radar GMTI via cyclic-shift transmission of orthogonal frequency division signals

    NASA Astrophysics Data System (ADS)

    Li, Fuyou; He, Feng; Dong, Zhen; Wu, Manqing

    2018-05-01

    Minimum detectable velocity (MDV) and maximum detectable velocity are both important in ground moving target indication (GMTI) systems. Smaller MDV can be achieved by longer baseline via multiple-input multiple-output (MIMO) radar. Maximum detectable velocity is decided by blind velocities associated with carrier frequencies, and blind velocities can be mitigated by orthogonal frequency division signals. However, the scattering echoes from different carrier frequencies are independent, which is not good for improving MDV performance. An improved cyclic-shift transmission is applied in MIMO GMTI system in this paper. MDV performance is improved due to the longer baseline, and maximum detectable velocity performance is improved due to the mitigation of blind velocities via multiple carrier frequencies. The signal model for this mode is established, the principle of mitigating blind velocities with orthogonal frequency division signals is presented; the performance of different MIMO GMTI waveforms is analysed; and the performance of different array configurations is analysed. Simulation results by space-time-frequency adaptive processing proves that our proposed method is a valid way to improve GMTI performance.

  1. A Novel Zero Velocity Interval Detection Algorithm for Self-Contained Pedestrian Navigation System with Inertial Sensors

    PubMed Central

    Tian, Xiaochun; Chen, Jiabin; Han, Yongqiang; Shang, Jianyu; Li, Nan

    2016-01-01

    Zero velocity update (ZUPT) plays an important role in pedestrian navigation algorithms with the premise that the zero velocity interval (ZVI) should be detected accurately and effectively. A novel adaptive ZVI detection algorithm based on a smoothed pseudo Wigner–Ville distribution to remove multiple frequencies intelligently (SPWVD-RMFI) is proposed in this paper. The novel algorithm adopts the SPWVD-RMFI method to extract the pedestrian gait frequency and to calculate the optimal ZVI detection threshold in real time by establishing the function relationships between the thresholds and the gait frequency; then, the adaptive adjustment of thresholds with gait frequency is realized and improves the ZVI detection precision. To put it into practice, a ZVI detection experiment is carried out; the result shows that compared with the traditional fixed threshold ZVI detection method, the adaptive ZVI detection algorithm can effectively reduce the false and missed detection rate of ZVI; this indicates that the novel algorithm has high detection precision and good robustness. Furthermore, pedestrian trajectory positioning experiments at different walking speeds are carried out to evaluate the influence of the novel algorithm on positioning precision. The results show that the ZVI detected by the adaptive ZVI detection algorithm for pedestrian trajectory calculation can achieve better performance. PMID:27669266

  2. A detector for high frequency modulation in auroral particle fluxes

    NASA Technical Reports Server (NTRS)

    Spiger, R. J.; Oehme, D.; Loewenstein, R. F.; Murphree, J.; Anderson, H. R.; Anderson, R.

    1974-01-01

    A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.

  3. Design, Fabrication, and Testing of Lumped Element Kinetic inductance Detectors for 3 mm CMB Observations

    NASA Technical Reports Server (NTRS)

    Lowitz, Amy E.; Brown, Ari David; Stevenson, Thomas R.; Timbie, Peter T.; Wollack, Edward J.

    2014-01-01

    Kinetic inductance detectors (KIDs) are a promising technology for low-noise, highly-multiplexible mm- and submm-wave detection. KIDs have a number of advantages over other detector technologies, which make them an appealing option in the cosmic microwave background B-mode anisotropy search, including passive frequency domain multiplexing and relatively simple fabrication, but have suffered from challenges associated with noise control. Here we describe design and fabrication of a 20-pixel prototype array of lumped element molybdenum KIDs. We show Q, frequency and temperature measurements from the array under dark conditions. We also present evidence for a double superconducting gap in molybdenum.

  4. Plasma waves near saturn: initial results from voyager 1.

    PubMed

    Gurnett, D A; Kurth, W S; Scarf, F L

    1981-04-10

    The Voyager 1 plasma wave instrument detected many familiar types of plasma waves during the encounter with Saturn, including ion-acoustic waves and electron plasma oscillations upstream of the bow shock, an intense burst of electrostatic noise at the shock, and chorus, hiss, electrostatic electron cyclotron waves, and upper hybrid resonance emissions in the inner magnetosphere. A clocklike Saturn rotational control of low-frequency radio emissions was observed, and evidence was obtained of possible control by the moon Dione. Strong plasma wave emissions were detected at the Titan encounter indicating the presence of a turbulent sheath extending around Titan, and upper hybrid resonance measurements of the electron density show the existence of a dense plume of plasma being carried downstream of Titan by the interaction with the rapidly rotating magnetosphere of Saturn.

  5. Reliability of unstable periodic orbit based control strategies in biological systems.

    PubMed

    Mishra, Nagender; Hasse, Maria; Biswal, B; Singh, Harinder P

    2015-04-01

    Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry of the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.

  6. Reliability of unstable periodic orbit based control strategies in biological systems

    NASA Astrophysics Data System (ADS)

    Mishra, Nagender; Hasse, Maria; Biswal, B.; Singh, Harinder P.

    2015-04-01

    Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry of the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.

  7. Bidirectional Regulation of Innate and Learned Behaviors That Rely on Frequency Discrimination by Cortical Inhibitory Neurons

    PubMed Central

    Aizenberg, Mark; Mwilambwe-Tshilobo, Laetitia; Briguglio, John J.; Natan, Ryan G.; Geffen, Maria N.

    2015-01-01

    The ability to discriminate tones of different frequencies is fundamentally important for everyday hearing. While neurons in the primary auditory cortex (AC) respond differentially to tones of different frequencies, whether and how AC regulates auditory behaviors that rely on frequency discrimination remains poorly understood. Here, we find that the level of activity of inhibitory neurons in AC controls frequency specificity in innate and learned auditory behaviors that rely on frequency discrimination. Photoactivation of parvalbumin-positive interneurons (PVs) improved the ability of the mouse to detect a shift in tone frequency, whereas photosuppression of PVs impaired the performance. Furthermore, photosuppression of PVs during discriminative auditory fear conditioning increased generalization of conditioned response across tone frequencies, whereas PV photoactivation preserved normal specificity of learning. The observed changes in behavioral performance were correlated with bidirectional changes in the magnitude of tone-evoked responses, consistent with predictions of a model of a coupled excitatory-inhibitory cortical network. Direct photoactivation of excitatory neurons, which did not change tone-evoked response magnitude, did not affect behavioral performance in either task. Our results identify a new function for inhibition in the auditory cortex, demonstrating that it can improve or impair acuity of innate and learned auditory behaviors that rely on frequency discrimination. PMID:26629746

  8. Change detection using landsat time series: A review of frequencies, preprocessing, algorithms, and applications

    NASA Astrophysics Data System (ADS)

    Zhu, Zhe

    2017-08-01

    The free and open access to all archived Landsat images in 2008 has completely changed the way of using Landsat data. Many novel change detection algorithms based on Landsat time series have been developed We present a comprehensive review of four important aspects of change detection studies based on Landsat time series, including frequencies, preprocessing, algorithms, and applications. We observed the trend that the more recent the study, the higher the frequency of Landsat time series used. We reviewed a series of image preprocessing steps, including atmospheric correction, cloud and cloud shadow detection, and composite/fusion/metrics techniques. We divided all change detection algorithms into six categories, including thresholding, differencing, segmentation, trajectory classification, statistical boundary, and regression. Within each category, six major characteristics of different algorithms, such as frequency, change index, univariate/multivariate, online/offline, abrupt/gradual change, and sub-pixel/pixel/spatial were analyzed. Moreover, some of the widely-used change detection algorithms were also discussed. Finally, we reviewed different change detection applications by dividing these applications into two categories, change target and change agent detection.

  9. Maximum Temperature Detection System for Integrated Circuits

    NASA Astrophysics Data System (ADS)

    Frankiewicz, Maciej; Kos, Andrzej

    2015-03-01

    The paper describes structure and measurement results of the system detecting present maximum temperature on the surface of an integrated circuit. The system consists of the set of proportional to absolute temperature sensors, temperature processing path and a digital part designed in VHDL. Analogue parts of the circuit where designed with full-custom technique. The system is a part of temperature-controlled oscillator circuit - a power management system based on dynamic frequency scaling method. The oscillator cooperates with microprocessor dedicated for thermal experiments. The whole system is implemented in UMC CMOS 0.18 μm (1.8 V) technology.

  10. The detection error of thermal test low-frequency cable based on M sequence correlation algorithm

    NASA Astrophysics Data System (ADS)

    Wu, Dongliang; Ge, Zheyang; Tong, Xin; Du, Chunlin

    2018-04-01

    The problem of low accuracy and low efficiency of off-line detecting on thermal test low-frequency cable faults could be solved by designing a cable fault detection system, based on FPGA export M sequence code(Linear feedback shift register sequence) as pulse signal source. The design principle of SSTDR (Spread spectrum time-domain reflectometry) reflection method and hardware on-line monitoring setup figure is discussed in this paper. Testing data show that, this detection error increases with fault location of thermal test low-frequency cable.

  11. Vibration assessment for thrombus formation in the centrifugal pump.

    PubMed

    Nakazawa, T; Makinouchi, K; Takami, Y; Glueck, J; Tayama, E; Nosé, Y

    1997-04-01

    To clarify the correlation of vibration and thrombus formation inside a rotary blood pump, 40 preliminary vibration studies were performed on pivot bearing centrifugal pumps. No such studies were found in the literature. The primary data acquisition equipment included an accelerometer (Isotron PE accelerometer, ENDEVCO, San Juan Capistrano, CA, U.S.A.), digitizing oscilloscope (TDS 420, Tektronix Inc., Pittsfield, MA, U.S.A.), and pivot bearing centrifugal pumps. The pump impeller was coupled magnetically to the driver magnet. The accelerometer was mounted on the top of the pump casing to sense radial and axial accelerations. To simulate the 3 common areas of thrombus formation, a piece of silicone rubber was attached to each of the following 3 locations as described: a circular shape on the center bottom of the impeller (CI), an eccentric shape on the bottom of the impeller (EI), and a circular shape on the center bottom casing (CC). A fast Fourier transform (FFT) method at 5 L/min against 100 mm Hg, with a pump rotating speed of 1,600 rpm was used. The frequency response of the vibration sensors used spans of 40 Hz to 2 kHz. The frequency domain was already integrated into the oscilloscope, allowing for comparison of the vibration results. The area of frequency domain at a radial direction was 206 +/- 12.7 mVHz in CI, 239.5 +/- 12.1 mVHz in EI, 365 +/- 12.9 mVHz in CC, and 163 +/- 7.9 mVHz in the control (control vs. CI p = 0.07, control vs. EI p < 0.001, control vs. CC p < 0.001, EI vs. CC p < 0.001, CI vs. CC p < 0.001). Three types of imitation thrombus formations were roughly distinguishable. These results suggested the possibility of detecting thrombus formation using vibration signals, and these studies revealed the usefulness of vibration monitoring to detect thrombus formation in a centrifugal pump.

  12. Detection of high-frequency energy changes in sustained vowels produced by singers

    PubMed Central

    Monson, Brian B.; Lotto, Andrew J.; Ternström, Sten

    2011-01-01

    The human voice spectrum above 5 kHz receives little attention. However, there are reasons to believe that this high-frequency energy (HFE) may play a role in perceived quality of voice in singing and speech. To fulfill this role, differences in HFE must first be detectable. To determine human ability to detect differences in HFE, the levels of the 8- and 16-kHz center-frequency octave bands were individually attenuated in sustained vowel sounds produced by singers and presented to listeners. Relatively small changes in HFE were in fact detectable, suggesting that this frequency range potentially contributes to the perception of especially the singing voice. Detection ability was greater in the 8-kHz octave than in the 16-kHz octave and varied with band energy level. PMID:21476681

  13. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.

    PubMed

    Dao, Duy; Salehizadeh, S M A; Noh, Yeonsik; Chong, Jo Woon; Cho, Chae Ho; McManus, Dave; Darling, Chad E; Mendelson, Yitzhak; Chon, Ki H

    2017-09-01

    Motion and noise artifacts (MNAs) impose limits on the usability of the photoplethysmogram (PPG), particularly in the context of ambulatory monitoring. MNAs can distort PPG, causing erroneous estimation of physiological parameters such as heart rate (HR) and arterial oxygen saturation (SpO2). In this study, we present a novel approach, "TifMA," based on using the time-frequency spectrum of PPG to first detect the MNA-corrupted data and next discard the nonusable part of the corrupted data. The term "nonusable" refers to segments of PPG data from which the HR signal cannot be recovered accurately. Two sequential classification procedures were included in the TifMA algorithm. The first classifier distinguishes between MNA-corrupted and MNA-free PPG data. Once a segment of data is deemed MNA-corrupted, the next classifier determines whether the HR can be recovered from the corrupted segment or not. A support vector machine (SVM) classifier was used to build a decision boundary for the first classification task using data segments from a training dataset. Features from time-frequency spectra of PPG were extracted to build the detection model. Five datasets were considered for evaluating TifMA performance: (1) and (2) were laboratory-controlled PPG recordings from forehead and finger pulse oximeter sensors with subjects making random movements, (3) and (4) were actual patient PPG recordings from UMass Memorial Medical Center with random free movements and (5) was a laboratory-controlled PPG recording dataset measured at the forehead while the subjects ran on a treadmill. The first dataset was used to analyze the noise sensitivity of the algorithm. Datasets 2-4 were used to evaluate the MNA detection phase of the algorithm. The results from the first phase of the algorithm (MNA detection) were compared to results from three existing MNA detection algorithms: the Hjorth, kurtosis-Shannon entropy, and time-domain variability-SVM approaches. This last is an approach recently developed in our laboratory. The proposed TifMA algorithm consistently provided higher detection rates than the other three methods, with accuracies greater than 95% for all data. Moreover, our algorithm was able to pinpoint the start and end times of the MNA with an error of less than 1 s in duration, whereas the next-best algorithm had a detection error of more than 2.2 s. The final, most challenging, dataset was collected to verify the performance of the algorithm in discriminating between corrupted data that were usable for accurate HR estimations and data that were nonusable. It was found that on average 48% of the data segments were found to have MNA, and of these, 38% could be used to provide reliable HR estimation.

  14. Y chromosome microdeletions frequency in idiopathic azoospermia, oligoasthenozoospermia, and oligospermia.

    PubMed

    Gholami, Delnya; Jafari-Ghahfarokhi, Hamideh; Nemati-Dehkordi, Maryam; Teimori, Hossien

    2017-11-01

    Genetic factors are candidates for about 30% of male infertility with sperm production-related abnormalities. Y chromosome microdeletions are responsible for around 10% of male infertility. These microdeletions generally occur in azoospermia factor on the Yq. That is often associated with the quantitative reduction of sperm. The aim of this cross-sectional study was to determine the frequency of Yq microdeletions among idiopathic azoospermic, oligoasthenozoospermic, and oligospermic men in Shohada infertility center, Chaharmahal va Bakhtiari province. A total of 81 idiopathic azoospermic, oligoasthenozoospermic, and oligospermic infertile men were selected as cases and 81 fertile men assigned to control group. For molecular investigations, 13 sequence-tagged site markers were chosen from azoospermia factor (AZF) region for detection of Y chromosome microdeletions and amplified by two separate multiplex-polymerase chain reaction. The relationship between the AZF microdeletions and incidence of male infertility in the family, consanguineous parents, smoking, and the levels of reproductive hormones among infertile men were investigated. The total frequency of the microdeletions was 6.17% (2 cases in azoospermic, 3 cases in oligoasthenozoospermic subgroups, and none in the oligospermic participants and the control group). Most deletions (3.7%) were seen in the AZFb followed by the AZFc (2.46%) and none in AZFa. No significant association was seen between the microdeletions and clinical characteristics. Although the frequency of Yq chromosome microdeletions in Chaharmahal va Bakhtiari province is lower than the mean frequency of Iran, the frequency is comparable to those reported by some studies in Iran.

  15. HLA-A and -B alleles and haplotypes in hemochromatosis probands with HFE C282Y homozygosity in central Alabama.

    PubMed

    Barton, James C; Acton, Ronald T

    2002-10-07

    We wanted to quantify HLA-A and -B allele and haplotype frequencies in Alabama hemochromatosis probands with HFE C282Y homozygosity and controls, and to compare results to those in other populations. Alleles were detected using DNA-based typing (probands) and microlymphocytotoxicity (controls). Alleles were determined in 139 probands (1,321 controls) and haplotypes in 118 probands (605 controls). In probands, A*03 positivity was 0.7482 (0.2739 controls; p = or < 0.0001; odds ratio (OR) 7.9); positivity for B*07, B*14, and B*56 was also increased. In probands, haplotypes A*03-B*07 and A*03-B*14 were more frequent (p < 0.0001, respectively; OR = 12.3 and 11.1, respectively). The haplotypes A*01-B*60, A*02-B*39, A*02-B*62, A*03-B*13, A*03-B*15, A*03-B*27, A*03-B*35, A*03-B*44, A*03-B*47, and A*03-B*57 were also significantly more frequent in probands. 37.3% of probands were HLA-haploidentical with other proband(s). A*03 and A*03-B*07 frequencies are increased in Alabama probands, as in other hemochromatosis cohorts. Increased absolute frequencies of A*03-B*35 have been reported only in the present Alabama probands and in hemochromatosis patients in Italy. Increased absolute frequencies of A*01-B*60, A*02-B*39, A*02-B*62, A*03-B*13, A*03-B*15, A*03-B*27, A*03-B*44, A*03-B*47, and A*03-B*57 in hemochromatosis cohorts have not been reported previously.

  16. Stably accessing octave-spanning microresonator frequency combs in the soliton regime

    PubMed Central

    Li, Qing; Briles, Travis C.; Westly, Daron A.; Drake, Tara E.; Stone, Jordan R.; Ilic, B. Robert; Diddams, Scott A.; Papp, Scott B.; Srinivasan, Kartik

    2017-01-01

    Microresonator frequency combs can be an enabling technology for optical frequency synthesis and timekeeping in low size, weight, and power architectures. Such systems require comb operation in low-noise, phase-coherent states such as solitons, with broad spectral bandwidths (e.g., octave-spanning) for self-referencing to detect the carrier-envelope offset frequency. However, accessing such states is complicated by thermo-optic dispersion. For example, in the Si3N4 platform, precisely dispersion-engineered structures can support broadband operation, but microsecond thermal time constants often require fast pump power or frequency control to stabilize the solitons. In contrast, here we consider how broadband soliton states can be accessed with simple pump laser frequency tuning, at a rate much slower than the thermal dynamics. We demonstrate octave-spanning soliton frequency combs in Si3N4 microresonators, including the generation of a multi-soliton state with a pump power near 40 mW and a single-soliton state with a pump power near 120 mW. We also develop a simplified two-step analysis to explain how these states are accessed without fast control of the pump laser, and outline the required thermal properties for such operation. Our model agrees with experimental results as well as numerical simulations based on a Lugiato-Lefever equation that incorporates thermo-optic dispersion. Moreover, it also explains an experimental observation that a member of an adjacent mode family on the red-detuned side of the pump mode can mitigate the thermal requirements for accessing soliton states. PMID:28603754

  17. A novel oscillation control for MEMS vibratory gyroscopes using a modified electromechanical amplitude modulation technique

    NASA Astrophysics Data System (ADS)

    Ma, Wei; Lin, Yiyu; Liu, Siqi; Zheng, Xudong; Jin, Zhonghe

    2017-02-01

    This paper reports a novel oscillation control algorithm for MEMS vibratory gyroscopes using a modified electromechanical amplitude modulation (MEAM) technique, which enhances the robustness against the frequency variation of the driving mode, compared to the conventional EAM (CEAM) scheme. In this approach, the carrier voltage exerted on the proof mass is frequency-modulated by the drive resonant frequency. Accordingly, the pick-up signal from the interface circuit involves a constant-frequency component that contains the amplitude and phase information of the vibration displacement. In other words, this informational detection signal is independent of the mechanical resonant frequency, which varies due to different batches, imprecise micro-fabrication and changing environmental temperature. In this paper, the automatic gain control loop together with the phase-locked loop are simultaneously analyzed using the averaging method and Routh-Hurwitz criterion, deriving the stability condition and the parameter optimization rules of the transient response. Then, a simulation model based on the real system is set up to evaluate the control algorithm. Further, the proposed MEAM method is tested using a field-programmable-gate-array based digital platform on a capacitive vibratory gyroscope. By optimizing the control parameters, the transient response of the drive amplitude reveals a settling time of 45.2 ms without overshoot, according well with the theoretical prediction and simulation results. The first measurement results show that the amplitude variance of the drive displacement is 12 ppm in an hour while the phase standard deviation is as low as 0.0004°. The mode-split gyroscope operating under atmospheric pressure demonstrates an outstanding performance. By virtue of the proposed MEAM method, the bias instability and angle random walk are measured to be 0.9° h-1 (improved by 2.4 times compared to the CEAM method) and 0.068° (√h)-1 (improved by 1.4 times), respectively.

  18. Computerized detection of breast cancer using resonance-frequency-based electrical impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Fan, Ming; Zhao, Weijie; Zheng, Bin; Li, Lihua

    2017-03-01

    This study developed and tested a multi-probe resonance-frequency-based electrical impedance spectroscopy (REIS) system aimed at detection of breast cancer. The REIS system consists of specially designed mechanical supporting device that can be easily lifted to fit women of different height, a seven probe sensor cup, and a computer providing software for system control and management. The sensor cup includes one central probe for direct contact with the nipple, and other six probes uniformly distributed at a distance of 35mm away from the center probe to enable contact with breast skin surface. It takes about 18 seconds for this system to complete a data acquisition process. We utilized this system for examination of breast cancer, collecting a dataset of 289 cases including biopsy verified 74 malignant and 215 benign tumors. After that, 23 REIS based features, including seven frequency, fifteen magnitude features were extracted, and an age feature. To reduce redundancy we selected 6 features using the evolutionary algorithm for classification. The area under a receiver operating characteristic curve (AUC) was computed to assess classifier performance. A multivariable logistic regression method was performed for detection of the tumors. The results of our study showed for the 23 REIS features AUC and ACC, Sensitivity and Specificity of 0.796, 0.727, 0.731 and 0.726, respectively. The AUC and ACC, Sensitivity and Specificity for the 6 REIS features of 0.840, 0.80, 0.703 and 0.833, respectively, and AUC of 0.662 and 0.619 for the frequency and magnitude based REIS features, respectively. The performance of the classifiers using all the 6 features was significantly better than solely using magnitude features (p=3.29e-08) and frequency features (5.61e-07). Smote algorithm was used to expand small samples to balance the dataset, the AUC after data balance of 0.846 increased than the original data classification performance. The results indicated that the REIS system is a promising tool for detection of breast cancer and may be acceptable for clinical implementation.

  19. Photon Shot Noise Limited Radio Frequency Electric Field Sensing Using Rydberg Atoms in Vapor Cells

    NASA Astrophysics Data System (ADS)

    Kumar, Santosh; Jahangiri, Akbar J.; Fan, Haoquan; Kuebler, Harald; Shaffer, James P.

    2017-04-01

    We report Rydberg atom-based radio frequency (RF) electrometry measurements at a sensitivity limited by probe laser photon shot noise. By utilizing the phenomena of electromagnetically induced transparency (EIT) in room temperature atomic vapor cells, Rydberg atoms can be used for absolute electric field measurements that significantly surpass conventional methods in utility, sensitivity and accuracy. We show that by using a Mach-Zehnder interferometer with homodyne detection or using frequency modulation spectroscopy with active control of residual amplitude modulation we can achieve a RF electric field detection sensitivity of 3 μVcm-1Hz/2. The sensitivity is limited by photon shot noise on the detector used to readout the probe laser of the EIT scheme. We suggest a new multi-photon scheme that can mitigate the effect of photon shot noise. The multi-photon approach allows an increase in probe laser power without decreasing atomic coherence times that result from collisions caused by an increase in Rydberg atom excitation. The multi-photon scheme also reduces Residual Doppler broadening enabling more accurate measurements to be carried out. This work is supported by DARPA, and NRO.

  20. [Effect of FABP2 gene G54A polymorphism on lipid and glucose metabolism in simple obesity children].

    PubMed

    Xu, Yunpeng; Rao, Xiaojiao; Hao, Min; Hou, Lijuan; Zhu, Xiaobo; Chang, Xiaotong

    2016-01-01

    To explore the relationship between intestinal fatty acid binding protein (FABP2) gene G54A polymorphism and simple childhood obesity, the effect of mutant 54A FABP2 gene on serum lipids and glucose metabolism. The total of 83 subjects with overweight/obesity and 100 subjects with healthy/normal weight were involved in this study. The G54A FABP2 gene allele and genotype frequencies between control group and overweight/obesity group were detected using polymerase chain reaction (PCR) -restriction fragment length polymorphism (RFLP) technology, and DNA sequences were confirmed by DNA sequencing. The automatic biochemical analyzer was used to detect fasting blood glucose (FBG), triglyceride (TG), total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C) and low-density lipoprotein cholesterol (LDL-C) levels. Plasma insulin (Ins) was detected by radiation immune method, free fatty acids (FFA) was tested by ELISA method, insulin resistance index ( HOMA-IR ) was also calculated. The correlation between FABP2 G54A polymorphism and the development of children' obesity was analyzed. The relation between FABP2 G54A polymorphism and abnormal blood lipid and insulin resistance was assessed. The results of study on FABP2 gene polymorphism revealed as followed. In overweight/obese groups, the frequencies of GG, GA, AA genotypes was 33.7%, 49.4% and 16.9%, respectively. In control group, the frequencies of GG, GA, AA genotypes was 51. 0% , 40. 0% and 9. 0% , respectively. The differences between two groups was statistically significant (Χ2 = 6.27, P < 0.05). In overweight/obesity group, the frequencies of alleles were 58.4% for 54G and 41.6% for 54A. In control group, the frequencies of alleles were 71.0% for 54G and 29.0% for 54A. There was significant differences (Χ2 = 6.32, P < 0.05). The plasma biochemical variables results showed that compared with the normal control group, plasma TG (P < 0.01), Ins (P < 0.05), HOMA-IR (P < 0.05) were elevated in overweight/obesity group, the difference between two groups was statistically significant. At the same time, in overweight/obesity group, the carriers of AA homozygous genotypes had significantly higher plasma TG levels than those with GG wild genotypes (P < 0.05). A increased tendency of plasma Ins, FFA levels and HOMA-IR was found in the carriers with AA homozygous genotypes, but no differences compared with those with GG wild genotypes. Compared with those with GG wild genotypes, related plasma biochemical variables in the carriers with GA heterozygous genotypes had no differences (P > 0.05). The FABP2 gene G54A polymorphism is related to simple children obesity and lipid metabolism abnormality. The allele encoding in FABP2 gene may be a potential factor contributing to promoting lipid metabolism abnormality of and insulin resistance.

Top