ERIC Educational Resources Information Center
Belanger, Rachelle M.; Conant, Stephanie B.; Grabowski, Gregory M.
2013-01-01
Rats can be used as a model organism to teach physiological concepts in a laboratory setting. This article describes a two-part laboratory that introduces students to hypothesis testing, experimental design, the appropriate use of controls and surgical techniques. Students perform both a castration and sham-control surgery on male rats and test…
Njelesani, Janet; Dacombe, Russell; Palmer, Tanith; Smith, Helen; Koudou, Benjamin; Bockarie, Moses; Bates, Imelda
2014-01-01
Background The lack of capacity in laboratory systems is a major barrier to achieving the aims of the London Declaration (2012) on neglected tropical diseases (NTDs). To counter this, capacity strengthening initiatives have been carried out in NTD laboratories worldwide. Many of these initiatives focus on individuals' skills or institutional processes and structures ignoring the crucial interactions between the laboratory and the wider national and international context. Furthermore, rigorous methods to assess these initiatives once they have been implemented are scarce. To address these gaps we developed a set of assessment and monitoring tools that can be used to determine the capacities required and achieved by laboratory systems at the individual, organizational, and national/international levels to support the control of NTDs. Methodology and principal findings We developed a set of qualitative and quantitative assessment and monitoring tools based on published evidence on optimal laboratory capacity. We implemented the tools with laboratory managers in Ghana, Malawi, Kenya, and Sri Lanka. Using the tools enabled us to identify strengths and gaps in the laboratory systems from the following perspectives: laboratory quality benchmarked against ISO 15189 standards, the potential for the laboratories to provide support to national and regional NTD control programmes, and the laboratory's position within relevant national and international networks and collaborations. Conclusion We have developed a set of mixed methods assessment and monitoring tools based on evidence derived from the components needed to strengthen the capacity of laboratory systems to control NTDs. Our tools help to systematically assess and monitor individual, organizational, and wider system level capacity of laboratory systems for NTD control and can be applied in different country contexts. PMID:24603407
Importance of implementing an analytical quality control system in a core laboratory.
Marques-Garcia, F; Garcia-Codesal, M F; Caro-Narros, M R; Contreras-SanFeliciano, T
2015-01-01
The aim of the clinical laboratory is to provide useful information for screening, diagnosis and monitoring of disease. The laboratory should ensure the quality of extra-analytical and analytical process, based on set criteria. To do this, it develops and implements a system of internal quality control, designed to detect errors, and compare its data with other laboratories, through external quality control. In this way it has a tool to detect the fulfillment of the objectives set, and in case of errors, allowing corrective actions to be made, and ensure the reliability of the results. This article sets out to describe the design and implementation of an internal quality control protocol, as well as its periodical assessment intervals (6 months) to determine compliance with pre-determined specifications (Stockholm Consensus(1)). A total of 40 biochemical and 15 immunochemical methods were evaluated using three different control materials. Next, a standard operation procedure was planned to develop a system of internal quality control that included calculating the error of the analytical process, setting quality specifications, and verifying compliance. The quality control data were then statistically depicted as means, standard deviations, and coefficients of variation, as well as systematic, random, and total errors. The quality specifications were then fixed and the operational rules to apply in the analytical process were calculated. Finally, our data were compared with those of other laboratories through an external quality assurance program. The development of an analytical quality control system is a highly structured process. This should be designed to detect errors that compromise the stability of the analytical process. The laboratory should review its quality indicators, systematic, random and total error at regular intervals, in order to ensure that they are meeting pre-determined specifications, and if not, apply the appropriate corrective actions. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.
Introducing Quality Control in the Chemistry Teaching Laboratory Using Control Charts
ERIC Educational Resources Information Center
Schazmann, Benjamin; Regan, Fiona; Ross, Mary; Diamond, Dermot; Paull, Brett
2009-01-01
Quality control (QC) measures are less prevalent in teaching laboratories than commercial settings possibly owing to a lack of commercial incentives or teaching resources. This article focuses on the use of QC assessment in the analytical techniques of high performance liquid chromatography (HPLC) and ultraviolet-visible spectroscopy (UV-vis) at…
AMT's Position on Physician's Office Laboratories.
ERIC Educational Resources Information Center
AMT Events, 1986
1986-01-01
The following standards are affirmed by the American Medical Technologists organization: (1) regardless of the size of the laboratory setting, the patient deserves the highest quality of laboratory service available; (2) certified personnel should be employed by physicians in office laboratories; (3) quality control should be mandatory and…
Zhang, Helen L; Omondi, Michael W; Musyoka, Augustine M; Afwamba, Isaac A; Swai, Remigi P; Karia, Francis P; Muiruri, Charles; Reddy, Elizabeth A; Crump, John A; Rubach, Matthew P
2016-08-01
Using a clinical research laboratory as a case study, we sought to characterize barriers to maintaining Good Clinical Laboratory Practice (GCLP) services in a developing world setting. Using a US Centers for Disease Control and Prevention framework for program evaluation in public health, we performed an evaluation of the Kilimanjaro Christian Medical Centre-Duke University Health Collaboration clinical research laboratory sections of the Kilimanjaro Clinical Research Institute in Moshi, Tanzania. Laboratory records from November 2012 through October 2014 were reviewed for this analysis. During the 2-year period of study, seven instrument malfunctions suspended testing required for open clinical trials. A median (range) of 9 (1-55) days elapsed between instrument malfunction and biomedical engineer service. Sixteen (76.1%) of 21 suppliers of reagents, controls, and consumables were based outside Tanzania. Test throughput among laboratory sections used a median (range) of 0.6% (0.2%-2.7%) of instrument capacity. Five (55.6%) of nine laboratory technologists left their posts over 2 years. These findings demonstrate that GCLP laboratory service provision in this setting is hampered by delays in biomedical engineer support, delays and extra costs in commodity procurement, low testing throughput, and high personnel turnover. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.
2011-01-01
Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.
Patrick, David M; Miller, Ruth R; Gardy, Jennifer L; Parker, Shoshana M; Morshed, Muhammad G; Steiner, Theodore S; Singer, Joel; Shojania, Kam; Tang, Patrick
2015-10-01
A subset of patients reporting a diagnosis of Lyme disease can be described as having alternatively diagnosed chronic Lyme syndrome (ADCLS), in which diagnosis is based on laboratory results from a nonreference Lyme specialty laboratory using in-house criteria. Patients with ADCLS report symptoms similar to those reported by patients with chronic fatigue syndrome (CFS). We performed a case-control study comparing patients with ADCLS and CFS to each other and to both healthy controls and controls with systemic lupus erythematosus (SLE). Subjects completed a history, physical exam, screening laboratory tests, 7 functional scales, reference serology for Lyme disease using Centers for Disease Control and Prevention criteria, reference serology for other tick-associated pathogens, and cytokine expression studies. The study enrolled 13 patients with ADCLS (12 of whom were diagnosed by 1 alternative US laboratory), 25 patients with CFS, 25 matched healthy controls, and 11 SLE controls. Baseline clinical data and functional scales indicate significant disability among ADCLS and CFS patients and many important differences between these groups and controls, but no significant differences between each other. No ADCLS patient was confirmed as having positive Lyme serology by reference laboratory testing, and there was no difference in distribution of positive serology for other tick-transmitted pathogens or cytokine expression across the groups. In British Columbia, a setting with low Lyme disease incidence, ADCLS patients have a similar phenotype to that of CFS patients. Disagreement between alternative and reference laboratory Lyme testing results in this setting is most likely explained by false-positive results from the alternative laboratory. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Strengthening laboratory systems in resource-limited settings.
Olmsted, Stuart S; Moore, Melinda; Meili, Robin C; Duber, Herbert C; Wasserman, Jeffrey; Sama, Preethi; Mundell, Ben; Hilborne, Lee H
2010-09-01
Considerable resources have been invested in recent years to improve laboratory systems in resource-limited settings. We reviewed published reports, interviewed major donor organizations, and conducted case studies of laboratory systems in 3 countries to assess how countries and donors have worked together to improve laboratory services. While infrastructure and the provision of services have seen improvement, important opportunities remain for further advancement. Implementation of national laboratory plans is inconsistent, human resources are limited, and quality laboratory services rarely extend to lower tier laboratories (eg, health clinics, district hospitals). Coordination within, between, and among governments and donor organizations is also frequently problematic. Laboratory standardization and quality control are improving but remain challenging, making accreditation a difficult goal. Host country governments and their external funding partners should coordinate their efforts effectively around a host country's own national laboratory plan to advance sustainable capacity development throughout a country's laboratory system.
Hirscher, Verena; Unbehaun, Thomas; Feige, Bernd; Nissen, Christoph; Riemann, Dieter; Spiegelhalder, Kai
2015-08-01
The validity of sleep laboratory investigations in patients with insomnia is important for researchers and clinicians. The objective of this study was to examine the first-night effect and the reverse first-night effect in patients with chronic primary insomnia compared with good sleeper controls. A retrospective comparison of a well-characterised sample of 50 patients with primary insomnia and 50 good sleeper controls was conducted with respect to 2 nights of polysomnography, and subjective sleep parameters in the sleep laboratory and the home setting. When comparing the first and second sleep laboratory night, a significant first-night effect was observed across both groups in the great majority of the investigated polysomnographic and subjective variables. However, patients with primary insomnia and good sleeper controls did not differ with respect to this effect. Regarding the comparison between the sleep laboratory nights and the home setting, unlike good sleeper controls, patients with primary insomnia reported an increased subjective sleep efficiency on both nights (in part due to a reduced bed time) and an increased subjective total sleep time on the second night. These results suggest that even the second sleep laboratory night does not necessarily provide clinicians and researchers with a representative insight into the sleep perception of patients with primary insomnia. Future studies should investigate whether these findings also hold for other patient populations. © 2015 European Sleep Research Society.
ERIC Educational Resources Information Center
Özbek, Necdet Sinan; Eker, Ilyas
2015-01-01
This study describes a set of real-time interactive experiments that address system identification and model reference adaptive control (MRAC) techniques. In constructing laboratory experiments that contribute to efficient teaching, experimental design and instructional strategy are crucial, but a process for doing this has yet to be defined. This…
Interval Analysis Approach to Prototype the Robust Control of the Laboratory Overhead Crane
NASA Astrophysics Data System (ADS)
Smoczek, J.; Szpytko, J.; Hyla, P.
2014-07-01
The paper describes the software-hardware equipment and control-measurement solutions elaborated to prototype the laboratory scaled overhead crane control system. The novelty approach to crane dynamic system modelling and fuzzy robust control scheme design is presented. The iterative procedure for designing a fuzzy scheduling control scheme is developed based on the interval analysis of discrete-time closed-loop system characteristic polynomial coefficients in the presence of rope length and mass of a payload variation to select the minimum set of operating points corresponding to the midpoints of membership functions at which the linear controllers are determined through desired poles assignment. The experimental results obtained on the laboratory stand are presented.
Combes, S A; Crall, J D; Mukherjee, S
2010-06-23
Much of our understanding of the control and dynamics of animal movement derives from controlled laboratory experiments. While many aspects of animal movement can be probed only in these settings, a more complete understanding of animal locomotion may be gained by linking experiments on relatively simple motions in the laboratory to studies of more complex behaviours in natural settings. To demonstrate the utility of this approach, we examined the effects of wing damage on dragonfly flight performance in both a laboratory drop-escape response and the more natural context of aerial predation. The laboratory experiment shows that hindwing area loss reduces vertical acceleration and average flight velocity, and the predation experiment demonstrates that this type of wing damage results in a significant decline in capture success. Taken together, these results suggest that wing damage may take a serious toll on wild dragonflies, potentially reducing both reproductive success and survival.
Fine PM measurements: personal and indoor air monitoring.
Jantunen, M; Hänninen, O; Koistinen, K; Hashim, J H
2002-12-01
This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.
ERIC Educational Resources Information Center
Birk, James P., Ed.
1989-01-01
Presented is a simple laboratory set-up for teaching microprocessor-controlled data acquisition as a part of an instrumental analysis course. Discussed are the experimental set-up, experimental procedures, and technical considerations for this technique. (CW)
Setterbo, Jacob J.; Chau, Anh; Fyhrie, Patricia B.; Hubbard, Mont; Upadhyaya, Shrini K.; Symons, Jennifer E.; Stover, Susan M.
2012-01-01
Background Racetrack surface is a risk factor for racehorse injuries and fatalities. Current research indicates that race surface mechanical properties may be influenced by material composition, moisture content, temperature, and maintenance. Race surface mechanical testing in a controlled laboratory setting would allow for objective evaluation of dynamic properties of surface and factors that affect surface behavior. Objective To develop a method for reconstruction of race surfaces in the laboratory and validate the method by comparison with racetrack measurements of dynamic surface properties. Methods Track-testing device (TTD) impact tests were conducted to simulate equine hoof impact on dirt and synthetic race surfaces; tests were performed both in situ (racetrack) and using laboratory reconstructions of harvested surface materials. Clegg Hammer in situ measurements were used to guide surface reconstruction in the laboratory. Dynamic surface properties were compared between in situ and laboratory settings. Relationships between racetrack TTD and Clegg Hammer measurements were analyzed using stepwise multiple linear regression. Results Most dynamic surface property setting differences (racetrack-laboratory) were small relative to surface material type differences (dirt-synthetic). Clegg Hammer measurements were more strongly correlated with TTD measurements on the synthetic surface than the dirt surface. On the dirt surface, Clegg Hammer decelerations were negatively correlated with TTD forces. Conclusions Laboratory reconstruction of racetrack surfaces guided by Clegg Hammer measurements yielded TTD impact measurements similar to in situ values. The negative correlation between TTD and Clegg Hammer measurements confirms the importance of instrument mass when drawing conclusions from testing results. Lighter impact devices may be less appropriate for assessing dynamic surface properties compared to testing equipment designed to simulate hoof impact (TTD). Potential Relevance Dynamic impact properties of race surfaces can be evaluated in a laboratory setting, allowing for further study of factors affecting surface behavior under controlled conditions. PMID:23227183
Empirical Analysis of the Use of the VISIR Remote Lab in Teaching Analog Electronics
ERIC Educational Resources Information Center
Garcia-Zubia, Javier; Cuadros, Jordi; Romero, Susana; Hernandez-Jayo, Unai; Orduña, Pablo; Guenaga, Mariluz; Gonzalez-Sabate, Lucinio; Gustavsson, Ingvar
2017-01-01
Remote laboratories give students the opportunity of experimenting in STEM by using the Internet to control and measure an experimental setting. Remote laboratories are increasingly used in the classroom to complement, or substitute for, hands-on laboratories, so it is important to know its learning value. While many authors approach this question…
Internal quality assurance in a clinical virology laboratory. II. Internal quality control.
Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R
1995-01-01
AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475
Design and Testing of Flight Control Laws on the RASCAL Research Helicopter
NASA Technical Reports Server (NTRS)
Frost, Chad R.; Hindson, William S.; Moralez. Ernesto, III; Tucker, George E.; Dryfoos, James B.
2001-01-01
Two unique sets of flight control laws were designed, tested and flown on the Army/NASA Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-60A Black Hawk helicopter. The first set of control laws used a simple rate feedback scheme, intended to facilitate the first flight and subsequent flight qualification of the RASCAL research flight control system. The second set of control laws comprised a more sophisticated model-following architecture. Both sets of flight control laws were developed and tested extensively using desktop-to-flight modeling, analysis, and simulation tools. Flight test data matched the model predicted responses well, providing both evidence and confidence that future flight control development for RASCAL will be efficient and accurate.
Quality Assurance of RNA Expression Profiling in Clinical Laboratories
Tang, Weihua; Hu, Zhiyuan; Muallem, Hind; Gulley, Margaret L.
2012-01-01
RNA expression profiles are increasingly used to diagnose and classify disease, based on expression patterns of as many as several thousand RNAs. To ensure quality of expression profiling services in clinical settings, a standard operating procedure incorporates multiple quality indicators and controls, beginning with preanalytic specimen preparation and proceeding thorough analysis, interpretation, and reporting. Before testing, histopathological examination of each cellular specimen, along with optional cell enrichment procedures, ensures adequacy of the input tissue. Other tactics include endogenous controls to evaluate adequacy of RNA and exogenous or spiked controls to evaluate run- and patient-specific performance of the test system, respectively. Unique aspects of quality assurance for array-based tests include controls for the pertinent outcome signatures that often supersede controls for each individual analyte, built-in redundancy for critical analytes or biochemical pathways, and software-supported scrutiny of abundant data by a laboratory physician who interprets the findings in a manner facilitating appropriate medical intervention. Access to high-quality reagents, instruments, and software from commercial sources promotes standardization and adoption in clinical settings, once an assay is vetted in validation studies as being analytically sound and clinically useful. Careful attention to the well-honed principles of laboratory medicine, along with guidance from government and professional groups on strategies to preserve RNA and manage large data sets, promotes clinical-grade assay performance. PMID:22020152
Web-Based Testing Tools for Electrical Engineering Courses
2001-09-01
ideas of distance learning are based on forming “ virtual teams” [2]. Each team is equipped with the same software packages and share information via...using virtual laboratories where they can simulate a laboratory experience in a web-based environment. They can also control laboratory devices over...possible to create a set of virtual laboratories that allow students to interact with the learning material at the same time that the student is
Combes, S. A.; Crall, J. D.; Mukherjee, S.
2010-01-01
Much of our understanding of the control and dynamics of animal movement derives from controlled laboratory experiments. While many aspects of animal movement can be probed only in these settings, a more complete understanding of animal locomotion may be gained by linking experiments on relatively simple motions in the laboratory to studies of more complex behaviours in natural settings. To demonstrate the utility of this approach, we examined the effects of wing damage on dragonfly flight performance in both a laboratory drop–escape response and the more natural context of aerial predation. The laboratory experiment shows that hindwing area loss reduces vertical acceleration and average flight velocity, and the predation experiment demonstrates that this type of wing damage results in a significant decline in capture success. Taken together, these results suggest that wing damage may take a serious toll on wild dragonflies, potentially reducing both reproductive success and survival. PMID:20236968
Lack of grading agreement among international hemostasis external quality assessment programs
Olson, John D.; Jennings, Ian; Meijer, Piet; Bon, Chantal; Bonar, Roslyn; Favaloro, Emmanuel J.; Higgins, Russell A.; Keeney, Michael; Mammen, Joy; Marlar, Richard A.; Meley, Roland; Nair, Sukesh C.; Nichols, William L.; Raby, Anne; Reverter, Joan C.; Srivastava, Alok; Walker, Isobel
2018-01-01
Laboratory quality programs rely on internal quality control and external quality assessment (EQA). EQA programs provide unknown specimens for the laboratory to test. The laboratory's result is compared with other (peer) laboratories performing the same test. EQA programs assign target values using a variety of methods statistical tools and performance assessment of ‘pass’ or ‘fail’ is made. EQA provider members of the international organization, external quality assurance in thrombosis and hemostasis, took part in a study to compare outcome of performance analysis using the same data set of laboratory results. Eleven EQA organizations using eight different analytical approaches participated. Data for a normal and prolonged activated partial thromboplastin time (aPTT) and a normal and reduced factor VIII (FVIII) from 218 laboratories were sent to the EQA providers who analyzed the data set using their method of evaluation for aPTT and FVIII, determining the performance for each laboratory record in the data set. Providers also summarized their statistical approach to assignment of target values and laboratory performance. Each laboratory record in the data set was graded pass/fail by all EQA providers for each of the four analytes. There was a lack of agreement of pass/fail grading among EQA programs. Discordance in the grading was 17.9 and 11% of normal and prolonged aPTT results, respectively, and 20.2 and 17.4% of normal and reduced FVIII results, respectively. All EQA programs in this study employed statistical methods compliant with the International Standardization Organization (ISO), ISO 13528, yet the evaluation of laboratory results for all four analytes showed remarkable grading discordance. PMID:29232255
ERIC Educational Resources Information Center
Shire, Stephanie Y.; Chang, Ya-Chih; Shih, Wendy; Bracaglia, Suzanne; Kodjoe, Maria; Kasari, Connie
2017-01-01
Background: Interventions found to be effective in research settings are often not as effective when implemented in community settings. Considering children with autism, studies have rarely examined the efficacy of laboratory-tested interventions on child outcomes in community settings using randomized controlled designs. Methods: One hundred and…
Inquiry in the Physical Geology Classroom: Supporting Students' Conceptual Model Development
ERIC Educational Resources Information Center
Miller, Heather R.; McNeal, Karen S.; Herbert, Bruce E.
2010-01-01
This study characterizes the impact of an inquiry-based learning (IBL) module versus a traditionally structured laboratory exercise. Laboratory sections were randomized into experimental and control groups. The experimental group was taught using IBL pedagogical techniques and included manipulation of large-scale data-sets, use of multiple…
Time Measurements with a Mobile Device Using Sound
ERIC Educational Resources Information Center
Wisman, Raymond F.; Spahn, Gabriel; Forinash, Kyle
2018-01-01
Data collection is a fundamental skill in science education, one that students generally practice in a controlled setting using equipment only available in the classroom laboratory. However, using smartphones with their built-in sensors and often free apps, many fundamental experiments can be performed outside the laboratory. Taking advantage of…
Voss with Bonner Ball Neutron Detector Control Unit in Destiny laboratory
2001-03-23
ISS002-E-5714 (23 March 2001) --- Astronaut James S. Voss, Expedition Two flight engineer, sets up the Bonner Ball Neutron Detector (BBND) in the Destiny laboratory. The BBND is connected to the Human Research Facility (HRF). This image was recorded with a digital still camera.
Common Learning Objectives for Undergraduate Control Systems Laboratories
ERIC Educational Resources Information Center
Reck, Rebecca M.
2017-01-01
Course objectives, like research objectives and product requirements, help provide clarity and direction for faculty and students. Unfortunately, course and laboratory objectives are not always clearly stated. Without a clear set of objectives, it can be hard to design a learning experience and determine whether students are achieving the intended…
Towards a rational antimicrobial testing policy in the laboratory.
Banaji, N; Oommen, S
2011-01-01
Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital's antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.
Guidance for Efficient Small Animal Imaging Quality Control.
Osborne, Dustin R; Kuntner, Claudia; Berr, Stuart; Stout, David
2017-08-01
Routine quality control is a critical aspect of properly maintaining high-performance small animal imaging instrumentation. A robust quality control program helps produce more reliable data both for academic purposes and as proof of system performance for contract imaging work. For preclinical imaging laboratories, the combination of costs and available resources often limits their ability to produce efficient and effective quality control programs. This work presents a series of simplified quality control procedures that are accessible to a wide range of preclinical imaging laboratories. Our intent is to provide minimum guidelines for routine quality control that can assist preclinical imaging specialists in setting up an appropriate quality control program for their facility.
Computer Instructional Aids for Undergraduate Control Education.
ERIC Educational Resources Information Center
Volz, Richard A.; And Others
Engineering is coming to rely more and more heavily upon the computer for computations, analyses, and graphic displays which aid the design process. A general purpose simulation system, the Time-shared Automatic Control Laboratory (TACL), and a set of computer-aided design programs, Control Oriented Interactive Graphic Analysis and Design…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Jeff; Rylander, Matthew; Boemer, Jens
The fourth solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utilities Commission (CPUC) supported the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with data provided from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E) conducted research to determine optimal default settings for distributed energy resource advanced inverter controls. The inverter functions studied are aligned with those developed by the California Smart Inverter Working Group (SIWG) and those being considered by the IEEE 1547more » Working Group. The advanced inverter controls examined to improve the distribution system response included power factor, volt-var, and volt-watt. The advanced inverter controls examined to improve the transmission system response included frequency and voltage ride-through as well as Dynamic Voltage Support. This CSI RD&D project accomplished the task of developing methods to derive distribution focused advanced inverter control settings, selecting a diverse set of feeders to evaluate the methods through detailed analysis, and evaluating the effectiveness of each method developed. Inverter settings focused on the transmission system performance were also evaluated and verified. Based on the findings of this work, the suggested advanced inverter settings and methods to determine settings can be used to improve the accommodation of distributed energy resources (PV specifically). The voltage impact from PV can be mitigated using power factor, volt-var, or volt-watt control, while the bulk system impact can be improved with frequency/voltage ride-through.« less
LABORATORY PROCESS CONTROLLER USING NATURAL LANGUAGE COMMANDS FROM A PERSONAL COMPUTER
NASA Technical Reports Server (NTRS)
Will, H.
1994-01-01
The complex environment of the typical research laboratory requires flexible process control. This program provides natural language process control from an IBM PC or compatible machine. Sometimes process control schedules require changes frequently, even several times per day. These changes may include adding, deleting, and rearranging steps in a process. This program sets up a process control system that can either run without an operator, or be run by workers with limited programming skills. The software system includes three programs. Two of the programs, written in FORTRAN77, record data and control research processes. The third program, written in Pascal, generates the FORTRAN subroutines used by the other two programs to identify the user commands with the user-written device drivers. The software system also includes an input data set which allows the user to define the user commands which are to be executed by the computer. To set the system up the operator writes device driver routines for all of the controlled devices. Once set up, this system requires only an input file containing natural language command lines which tell the system what to do and when to do it. The operator can make up custom commands for operating and taking data from external research equipment at any time of the day or night without the operator in attendance. This process control system requires a personal computer operating under MS-DOS with suitable hardware interfaces to all controlled devices. The program requires a FORTRAN77 compiler and user-written device drivers. This program was developed in 1989 and has a memory requirement of about 62 Kbytes.
Gargis, Amy S; Kalman, Lisa; Lubin, Ira M
2016-12-01
Clinical microbiology and public health laboratories are beginning to utilize next-generation sequencing (NGS) for a range of applications. This technology has the potential to transform the field by providing approaches that will complement, or even replace, many conventional laboratory tests. While the benefits of NGS are significant, the complexities of these assays require an evolving set of standards to ensure testing quality. Regulatory and accreditation requirements, professional guidelines, and best practices that help ensure the quality of NGS-based tests are emerging. This review highlights currently available standards and guidelines for the implementation of NGS in the clinical and public health laboratory setting, and it includes considerations for NGS test validation, quality control procedures, proficiency testing, and reference materials. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Mathur, Vani A; Kiley, Kasey B; Haywood, Carlton; Bediako, Shawn M; Lanzkron, Sophie; Carroll, C Patrick; Buenaver, Luis F; Pejsa, Megan; Edwards, Robert R; Haythornthwaite, Jennifer A; Campbell, Claudia M
2016-12-01
People living with sickle cell disease (SCD) experience severe episodic and chronic pain and frequently report poor interpersonal treatment within health-care settings. In this particularly relevant context, we examined the relationship between perceived discrimination and both clinical and laboratory pain. Seventy-one individuals with SCD provided self-reports of experiences with discrimination in health-care settings and clinical pain severity, and completed a psychophysical pain testing battery in the laboratory. Discrimination in health-care settings was correlated with greater clinical pain severity and enhanced sensitivity to multiple laboratory-induced pain measures, as well as stress, depression, and sleep. After controlling for relevant covariates, discrimination remained a significant predictor of mechanical temporal summation (a marker of central pain facilitation), but not clinical pain severity or suprathreshold heat pain response. Furthermore, a significant interaction between experience with discrimination and clinical pain severity was associated with mechanical temporal summation; increased experience with discrimination was associated with an increased correlation between clinical pain severity and temporal summation of pain. Perceived discrimination within health-care settings was associated with pain facilitation. These findings suggest that discrimination may be related to increased central sensitization among SCD patients, and more broadly that health-care social environments may interact with pain pathophysiology.
Techniques for Field Application of Lingual Ultrasound Imaging
ERIC Educational Resources Information Center
Gick, Bryan; Bird, Sonya; Wilson, Ian
2005-01-01
Techniques are discussed for using ultrasound for lingual imaging in field-related applications. The greatest challenges we have faced distinguishing the field setting from the laboratory setting are the lack of controlled head/transducer movement, and the related issue of tissue compression. Two experiments are reported. First, a pilot study…
The Czech External Quality Control system in medical microbiology and parasitology.
Slosárek, M; Kríz, B
2000-11-01
The External Quality Control (EQC) system in activities of laboratories engaged in medical microbiology and parasitology was established in the Czech Republic in 1993 when to the first laboratories which applied coded serum samples were sent for diagnosis of viral hepatitis and bacterial strains for identification. In the course of years the number of control areas increased and in 2000 there were 31 and the number of those interested in participation in EQC increased from 79 in 1993 to 434 in 2000. This year a total of 13,239 samples will be sent to laboratories. Gradually thus almost all microbiological and parasitological laboratories concerned with examination of clinical material became involved. Seven-year experience with EQC in the Czech Republic revealed that gradually the results of various examinations became more accurate, that methods became standardized and the most suitable examination sets are used.
Alabi, Abraham Sunday; Traoré, Afsatou Ndama; Loembe, Marguerite Massinga; Ateba-Ngoa, Ulysse; Frank, Matthias; Adegnika, Ayola Akim; Lell, Bertrand; Mahoumbou, Jocelyn; Köhler, Carsten; Kremsner, Peter Gottfried; Grobusch, Martin Peter
2017-03-01
Both routine and research tuberculosis (TB) laboratory capacity urgently need to be expanded in large parts of Sub-Saharan Africa. In 2009, the Centre de Recherches Médicales de Lambaréné (CERMEL) took a strategic decision to expand its activities by building TB laboratory capacity to address research questions and to improve routine diagnostic and treatment capacity. Over the past 7 years, a standard laboratory has been developed that is contributing significantly to TB diagnosis, treatment, and control in Gabon; training has also been provided for TB research staff in Central Africa. CERMEL has a cordial relationship with the Gabon National TB Control Programme (PNLT), which has culminated in a successful Global Fund joint application. This endeavour is considered a model for similar developments needed in areas of high TB prevalence and where TB control remains poor to date. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Kay, Jack F
2012-08-01
Laboratories involved in the analyses of veterinary drug residues are under increasing pressure to demonstrate that they produce meaningful and reliable data. Quality assurance and quality control systems are implemented in laboratories to provide evidence of this and these are subject to external assessment to ensure that they are effective. Audits to ISO/IEC 17025:2005, an internationally accepted standard, and subsequent accreditation provide laboratories and their customers with a degree of assurance that the laboratories are operating in control and the data they report can be relied on. However, national or regional authorities may place additional requirements on laboratories to ensure quality data are reported. For example, in the European Union, all official control laboratories involved in veterinary drug residue analyses must also meet the requirements of European Commission Decision 2002/657/EC which sets performance criteria for analytical methods used in this area and these are subject to additional audits by national or regional authorities. All audits place considerable time and resource demands on laboratories and this paper discusses the burden audits place on laboratories and describes a UK initiative to combine these audits to the benefit of both the regulatory authority and the laboratory. © 2012 John Wiley & Sons, Ltd.
A new method for eliciting three speaking styles in the laboratory
Harnsberger, James D.; Wright, Richard; Pisoni, David B.
2009-01-01
In this study, a method was developed to elicit three different speaking styles, reduced, citation, and hyperarticulated, using controlled sentence materials in a laboratory setting. In the first set of experiments, the reduced style was elicited by having twelve talkers read a sentence while carrying out a distractor task that involved recalling from short-term memory an individually-calibrated number of digits. The citation style corresponded to read speech in the laboratory. The hyperarticulated style was elicited by prompting talkers (twice) to reread the sentences more carefully. The results of perceptual tests with naïve listeners and an acoustic analysis showed that six of the twelve talkers produced a reduced style of speech for the test sentences in the distractor task relative to the same sentences in the citation style condition. In addition, all talkers consistently produced sentences in the citation and hyperarticulated styles. In the second set of experiments, the reduced style was elicited by increasing the number of digits in the distractor task by one (a heavier cognitive load). The procedures for eliciting citation and hyperarticulated sentences remained unchanged. Ten talkers were recorded in the second experiment. The results showed that six out of ten talkers differentiated all three styles as predicted (70% of all sentences recorded). In addition, all talkers consistently produced sentences in the citation and hyperarticulated styles. Overall, the results demonstrate that it is possible to elicit controlled sentence stimulus materials varying in speaking style in a laboratory setting, although the method requires further refinement to elicit these styles more consistently from individual participants. PMID:19562041
A new method for eliciting three speaking styles in the laboratory.
Harnsberger, James D; Wright, Richard; Pisoni, David B
2008-04-01
In this study, a method was developed to elicit three different speaking styles, reduced, citation, and hyperarticulated, using controlled sentence materials in a laboratory setting. In the first set of experiments, the reduced style was elicited by having twelve talkers read a sentence while carrying out a distractor task that involved recalling from short-term memory an individually-calibrated number of digits. The citation style corresponded to read speech in the laboratory. The hyperarticulated style was elicited by prompting talkers (twice) to reread the sentences more carefully. The results of perceptual tests with naïve listeners and an acoustic analysis showed that six of the twelve talkers produced a reduced style of speech for the test sentences in the distractor task relative to the same sentences in the citation style condition. In addition, all talkers consistently produced sentences in the citation and hyperarticulated styles. In the second set of experiments, the reduced style was elicited by increasing the number of digits in the distractor task by one (a heavier cognitive load). The procedures for eliciting citation and hyperarticulated sentences remained unchanged. Ten talkers were recorded in the second experiment. The results showed that six out of ten talkers differentiated all three styles as predicted (70% of all sentences recorded). In addition, all talkers consistently produced sentences in the citation and hyperarticulated styles. Overall, the results demonstrate that it is possible to elicit controlled sentence stimulus materials varying in speaking style in a laboratory setting, although the method requires further refinement to elicit these styles more consistently from individual participants.
Motion control system of MAX IV Laboratory soft x-ray beamlines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sjöblom, Peter, E-mail: peter.sjoblom@maxlab.lu.se; Lindberg, Mirjam, E-mail: mirjam.lindberg@maxlab.lu.se; Forsberg, Johan, E-mail: johan.forsberg@maxlab.lu.se
2016-07-27
At the MAX IV Laboratory, five new soft x-ray beamlines are under development. The first is Species and it will be used to develop and set the standard of the control system, which will be common across the facility. All motion axes at MAX IV will be motorized using stepper motors steered by the IcePAP motion controller and a mixture of absolute and incremental encoders following a predefined coordinate system. The control system software is built in Tango and uses the Python-based Sardana framework. The user controls the entire beamline through a synoptic overview and Sardana is used to runmore » the scans.« less
Garcia, Ediberto; Newfang, Daniel; Coyle, Jayme P; Blake, Charles L; Spencer, John W; Burrelli, Leonard G; Johnson, Giffe T; Harbison, Raymond D
2018-07-01
Three independently conducted asbestos exposure evaluations were conducted using wire gauze pads similar to standard practice in the laboratory setting. All testing occurred in a controlled atmosphere inside an enclosed chamber simulating a laboratory setting. Separate teams consisting of a laboratory technician, or technician and assistant simulated common tasks involving wire gauze pads, including heating and direct wire gauze manipulation. Area and personal air samples were collected and evaluated for asbestos consistent with the National Institute of Occupational Safety Health method 7400 and 7402, and the Asbestos Hazard Emergency Response Act (AHERA) method. Bulk gauze pad samples were analyzed by Polarized Light Microscopy and Transmission Electron Microscopy to determine asbestos content. Among air samples, chrysotile asbestos was the only fiber found in the first and third experiments, and tremolite asbestos for the second experiment. None of the air samples contained asbestos in concentrations above the current permissible regulatory levels promulgated by OSHA. These findings indicate that the level of asbestos exposure when working with wire gauze pads in the laboratory setting is much lower than levels associated with asbestosis or asbestos-related lung cancer and mesothelioma. Copyright © 2018. Published by Elsevier Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-01
... capability for non- vital laboratory room electrical loads that provides an engineered control to reduce..., approximately two orders of magnitude higher than our evaluation guideline for selecting safety class controls. Approval of the DSA included recognition of weaknesses in the facility's control set and the need to...
The LANL P14 temperature control electronics for the waveshaping filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nahman, N.S.
1993-12-17
The Pulse Waveform Standard is designed to be operated in a laboratory environment in which the temperature is controlled and maintained at 22 C. The temperature controller of the Pulse Waveform Standard must be set to operate at 30 C. This report gives information for calibrating and maintaining the temperature control electronics. Temperature controller circuit diagrams and temperature controller circuit board layouts are included.
Roles of laboratories and laboratory systems in effective tuberculosis programmes.
Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul
2007-05-01
Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.
Mapping of the US Domestic Influenza Virologic Surveillance Landscape.
Jester, Barbara; Schwerzmann, Joy; Mustaquim, Desiree; Aden, Tricia; Brammer, Lynnette; Humes, Rosemary; Shult, Pete; Shahangian, Shahram; Gubareva, Larisa; Xu, Xiyan; Miller, Joseph; Jernigan, Daniel
2018-07-17
Influenza virologic surveillance is critical each season for tracking influenza circulation, following trends in antiviral drug resistance, detecting novel influenza infections in humans, and selecting viruses for use in annual seasonal vaccine production. We developed a framework and process map for characterizing the landscape of US influenza virologic surveillance into 5 tiers of influenza testing: outpatient settings (tier 1), inpatient settings and commercial laboratories (tier 2), state public health laboratories (tier 3), National Influenza Reference Center laboratories (tier 4), and Centers for Disease Control and Prevention laboratories (tier 5). During the 2015-16 season, the numbers of influenza tests directly contributing to virologic surveillance were 804,000 in tiers 1 and 2; 78,000 in tier 3; 2,800 in tier 4; and 3,400 in tier 5. With the release of the 2017 US Pandemic Influenza Plan, the proposed framework will support public health officials in modeling, surveillance, and pandemic planning and response.
NASA Technical Reports Server (NTRS)
Defeo, P.; Doane, D.; Saito, J.
1982-01-01
A Digital Flight Control Systems Verification Laboratory (DFCSVL) has been established at NASA Ames Research Center. This report describes the major elements of the laboratory, the research activities that can be supported in the area of verification and validation of digital flight control systems (DFCS), and the operating scenarios within which these activities can be carried out. The DFCSVL consists of a palletized dual-dual flight-control system linked to a dedicated PDP-11/60 processor. Major software support programs are hosted in a remotely located UNIVAC 1100 accessible from the PDP-11/60 through a modem link. Important features of the DFCSVL include extensive hardware and software fault insertion capabilities, a real-time closed loop environment to exercise the DFCS, an integrated set of software verification tools, and a user-oriented interface to all the resources and capabilities.
Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A
2015-12-01
The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.
Berk, L E; Landau, S
1993-04-01
Learning disabled (LD) children are often targets for cognitive-behavioral interventions designed to train them in effective use of a self-directed speech. The purpose of this study was to determine if, indeed, these children display immature private speech in the naturalistic classroom setting. Comparisons were made of the private speech, motor accompaniment to task, and attention of LD and normally achieving classmates during academic seatwork. Setting effects were examined by comparing classroom data with observations during academic seatwork and puzzle solving in the laboratory. Finally, a subgroup of LD children symptomatic of attention-deficit hyperactivity disorder (ADHD) was compared with pure LD and normally achieving controls to determine if the presumed immature private speech is a function of a learning disability or externalizing behavior problems. Results indicated that LD children used more task-relevant private speech than controls, an effect that was especially pronounced for the LD/ADHD subgroup. Use of private speech was setting- and task-specific. Implications for intervention and future research methodology are discussed.
Experiential learning in control systems laboratories and engineering project management
NASA Astrophysics Data System (ADS)
Reck, Rebecca Marie
Experiential learning is a process by which a student creates knowledge through the insights gained from an experience. Kolb's model of experiential learning is a cycle of four modes: (1) concrete experience, (2) reflective observation, (3) abstract conceptualization, and (4) active experimentation. His model is used in each of the three studies presented in this dissertation. Laboratories are a popular way to apply the experiential learning modes in STEM courses. Laboratory kits allow students to take home laboratory equipment to complete experiments on their own time. Although students like laboratory kits, no previous studies compared student learning outcomes on assignments using laboratory kits with existing laboratory equipment. In this study, we examined the similarities and differences between the experiences of students who used a portable laboratory kit and students who used the traditional equipment. During the 2014- 2015 academic year, we conducted a quasi-experiment to compare students' achievement of learning outcomes and their experiences in the instructional laboratory for an introductory control systems course. Half of the laboratory sections in each semester used the existing equipment, while the other sections used a new kit. We collected both quantitative data and qualitative data. We did not identify any major differences in the student experience based on the equipment they used. Course objectives, like research objectives and product requirements, help provide clarity and direction for faculty and students. Unfortunately, course and laboratory objectives are not always clearly stated. Without a clear set of objectives, it can be hard to design a learning experience and determine whether students are achieving the intended outcomes of the course or laboratory. In this study, I identified a common set of laboratory objectives, concepts, and components of a laboratory apparatus for undergraduate control systems laboratories. During the summer of 2015, a panel of 40 control systems faculty members, from a variety of institutions, completed a multi-round Delphi survey in order to bring them toward consensus on the common aspects of their laboratories. The following winter, 45 additional faculty members and practitioners from the control systems community completed a follow-up survey to gather feedback on the results of the Delphi survey. During the Delphi study, the panelists identified 15 laboratory objectives, 26 concepts, and 15 components that were common in their laboratories. Then in both the Delphi survey and follow-up survey each participant rated the importance of each of these items. While the average ratings differed slightly between the two groups, the order of each set of items was compared with two different tests and the order was found to be similar. Some of the common and important learning objectives include connecting theory to what is implemented and observed in the laboratory, designing controllers, and modeling and simulating systems. The most common component in both groups was Math-Works software. Some of the common concepts include block diagrams, stability, and PID control. Defining common aspects of undergraduate control systems laboratories enables common development, detailed comparisons, and simplified adaptation of equipment and experiments between campuses and programs. Throughout an undergraduate program in engineering, there are multiple opportunities for hands-on laboratory experiences that are related to course content. However, a similarly immersive experience for project management graduate students is harder to incorporate for all students in a course at once. This study explores an experiential learning opportunity for graduate students in engineering management or project management programs. The project management students enroll in a project management course. Undergraduate students interested in working on a project with a real customer enroll in a different projects course. Two students from the project management course function as project managers and lead a team of undergraduate students in the second course through a project. I studied how closely the project management experience in these courses aligns with engineering project management in industry. In the spring of 2015, I enrolled in the project management course at a large Midwestern university. I used analytic autoethnography to compare my experiences in the course with my experiences as a project engineer at a large aerospace company. I found that the experience in the course provided an authentic and comprehensive opportunity to practice most of the skills listed in the Project Management Book of Knowledge (an industry standard) as necessary for project managers. Some components of the course that made it successful: I was the project manager for the whole term, I worked with a real client, and the team defined and delivered the project before the end of the semester.
Severe Self-Injurious Behavior: The Problem of Clinical Control
ERIC Educational Resources Information Center
Romanczyk, Raymond G.; Goren, Elizabeth R.
1975-01-01
The long-term treatment program and follow-up of a case of chronic, severe, multiple self-injurious behavior is presented. Contingent electric shock and differential reinforcement of other behavior were the primary techniques utilized. Total suppression was achieved in the laboratory setting, but extending control to the natural environment proved…
EDUCATION, CHILDREN AND COMFORT.
ERIC Educational Resources Information Center
Iowa Univ., Iowa City.
TWO SIMILAR CLASSROOMS WERE SET UP IN THE LENNOX LIVING LABORATORY, DES MOINES, IOWA, ONE FOR EXPERIMENTAL GROUPS AND ONE FOR CONTROL GROUPS. TEMPERATURE, AIR CIRCULATION AND HUMIDITY CAN BE CONTROLLED AND MEASURED IN BOTH ROOMS. THE ROOMS ARE OF SIMILAR SIZE, LAYOUT AND CONSTRUCTION, THE THERMAL ENVIRONMENT BEING THE ONLY VARIABLE. THE FOLLOWING…
Transitioning EEG experiments away from the laboratory using a Raspberry Pi 2.
Kuziek, Jonathan W P; Shienh, Axita; Mathewson, Kyle E
2017-02-01
Electroencephalography (EEG) experiments are typically performed in controlled laboratory settings to minimise noise and produce reliable measurements. These controlled conditions also reduce the applicability of the obtained results to more varied environments and may limit their relevance to everyday situations. Advances in computer portability may increase the mobility and applicability of EEG results while decreasing costs. In this experiment we show that stimulus presentation using a Raspberry Pi 2 computer provides a low cost, reliable alternative to a traditional desktop PC in the administration of EEG experimental tasks. Significant and reliable MMN and P3 activity, typical event-related potentials (ERPs) associated with an auditory oddball paradigm, were measured while experiments were administered using the Raspberry Pi 2. While latency differences in ERP triggering were observed between systems, these differences reduced power only marginally, likely due to the reduced processing power of the Raspberry Pi 2. An auditory oddball task administered using the Raspberry Pi 2 produced similar ERPs to those derived from a desktop PC in a laboratory setting. Despite temporal differences and slight increases in trials needed for similar statistical power, the Raspberry Pi 2 can be used to design and present auditory experiments comparable to a PC. Our results show that the Raspberry Pi 2 is a low cost alternative to the desktop PC when administering EEG experiments and, due to its small size and low power consumption, will enable mobile EEG experiments unconstrained by a traditional laboratory setting. Copyright © 2016 Elsevier B.V. All rights reserved.
Fulga, Netta
2013-06-01
Quality management and accreditation in the analytical laboratory setting are developing rapidly and becoming the standard worldwide. Quality management refers to all the activities used by organizations to ensure product or service consistency. Accreditation is a formal recognition by an authoritative regulatory body that a laboratory is competent to perform examinations and report results. The Motherisk Drug Testing Laboratory is licensed to operate at the Hospital for Sick Children in Toronto, Ontario. The laboratory performs toxicology tests of hair and meconium samples for research and clinical purposes. Most of the samples are involved in a chain of custody cases. Establishing a quality management system and achieving accreditation became mandatory by legislation for all Ontario clinical laboratories since 2003. The Ontario Laboratory Accreditation program is based on International Organization for Standardization 15189-Medical laboratories-Particular requirements for quality and competence, an international standard that has been adopted as a national standard in Canada. The implementation of a quality management system involves management commitment, planning and staff education, documentation of the system, validation of processes, and assessment against the requirements. The maintenance of a quality management system requires control and monitoring of the entire laboratory path of workflow. The process of transformation of a research/clinical laboratory into an accredited laboratory, and the benefits of maintaining an effective quality management system, are presented in this article.
Bastian, Thomas; Maire, Aurélia; Dugas, Julien; Ataya, Abbas; Villars, Clément; Gris, Florence; Perrin, Emilie; Caritu, Yanis; Doron, Maeva; Blanc, Stéphane; Jallon, Pierre; Simon, Chantal
2015-03-15
"Objective" methods to monitor physical activity and sedentary patterns in free-living conditions are necessary to further our understanding of their impacts on health. In recent years, many software solutions capable of automatically identifying activity types from portable accelerometry data have been developed, with promising results in controlled conditions, but virtually no reports on field tests. An automatic classification algorithm initially developed using laboratory-acquired data (59 subjects engaging in a set of 24 standardized activities) to discriminate between 8 activity classes (lying, slouching, sitting, standing, walking, running, and cycling) was applied to data collected in the field. Twenty volunteers equipped with a hip-worn triaxial accelerometer performed at their own pace an activity set that included, among others, activities such as walking the streets, running, cycling, and taking the bus. Performances of the laboratory-calibrated classification algorithm were compared with those of an alternative version of the same model including field-collected data in the learning set. Despite good results in laboratory conditions, the performances of the laboratory-calibrated algorithm (assessed by confusion matrices) decreased for several activities when applied to free-living data. Recalibrating the algorithm with data closer to real-life conditions and from an independent group of subjects proved useful, especially for the detection of sedentary behaviors while in transports, thereby improving the detection of overall sitting (sensitivity: laboratory model = 24.9%; recalibrated model = 95.7%). Automatic identification methods should be developed using data acquired in free-living conditions rather than data from standardized laboratory activity sets only, and their limits carefully tested before they are used in field studies. Copyright © 2015 the American Physiological Society.
QCloud: A cloud-based quality control system for mass spectrometry-based proteomics laboratories
Chiva, Cristina; Olivella, Roger; Borràs, Eva; Espadas, Guadalupe; Pastor, Olga; Solé, Amanda
2018-01-01
The increasing number of biomedical and translational applications in mass spectrometry-based proteomics poses new analytical challenges and raises the need for automated quality control systems. Despite previous efforts to set standard file formats, data processing workflows and key evaluation parameters for quality control, automated quality control systems are not yet widespread among proteomics laboratories, which limits the acquisition of high-quality results, inter-laboratory comparisons and the assessment of variability of instrumental platforms. Here we present QCloud, a cloud-based system to support proteomics laboratories in daily quality assessment using a user-friendly interface, easy setup, automated data processing and archiving, and unbiased instrument evaluation. QCloud supports the most common targeted and untargeted proteomics workflows, it accepts data formats from different vendors and it enables the annotation of acquired data and reporting incidences. A complete version of the QCloud system has successfully been developed and it is now open to the proteomics community (http://qcloud.crg.eu). QCloud system is an open source project, publicly available under a Creative Commons License Attribution-ShareAlike 4.0. PMID:29324744
Dimech, Wayne; Karakaltsas, Marina; Vincini, Giuseppe A
2018-05-25
A general trend towards conducting infectious disease serology testing in centralized laboratories means that quality control (QC) principles used for clinical chemistry testing are applied to infectious disease testing. However, no systematic assessment of methods used to establish QC limits has been applied to infectious disease serology testing. A total of 103 QC data sets, obtained from six different infectious disease serology analytes, were parsed through standard methods for establishing statistical control limits, including guidelines from Public Health England, USA Clinical and Laboratory Standards Institute (CLSI), German Richtlinien der Bundesärztekammer (RiliBÄK) and Australian QConnect. The percentage of QC results failing each method was compared. The percentage of data sets having more than 20% of QC results failing Westgard rules when the first 20 results were used to calculate the mean±2 standard deviation (SD) ranged from 3 (2.9%) for R4S to 66 (64.1%) for 10X rule, whereas the percentage ranged from 0 (0%) for R4S to 32 (40.5%) for 10X when the first 100 results were used to calculate the mean±2 SD. By contrast, the percentage of data sets with >20% failing the RiliBÄK control limits was 25 (24.3%). Only two data sets (1.9%) had more than 20% of results outside the QConnect Limits. The rate of failure of QCs using QConnect Limits was more applicable for monitoring infectious disease serology testing compared with UK Public Health, CLSI and RiliBÄK, as the alternatives to QConnect Limits reported an unacceptably high percentage of failures across the 103 data sets.
Panteghini, Mauro; Ceriotti, Ferruccio; Jones, Graham; Oosterhuis, Wytze; Plebani, Mario; Sandberg, Sverre
2017-10-26
Measurements in clinical laboratories produce results needed in the diagnosis and monitoring of patients. These results are always characterized by some uncertainty. What quality is needed and what measurement errors can be tolerated without jeopardizing patient safety should therefore be defined and specified for each analyte having clinical use. When these specifications are defined, the total examination process will be "fit for purpose" and the laboratory professionals should then set up rules to control the measuring systems to ensure they perform within specifications. The laboratory community has used different models to set performance specifications (PS). Recently, it was felt that there was a need to revisit different models and, at the same time, to emphasize the presuppositions for using the different models. Therefore, in 2014 the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) organized a Strategic Conference in Milan. It was felt that there was a need for more detailed discussions on, for instance, PS for EQAS, which measurands should use which models to set PS and how to set PS for the extra-analytical phases. There was also a need to critically evaluate the quality of data on biological variation studies and further discussing the use of the total error (TE) concept. Consequently, EFLM established five Task Finish Groups (TFGs) to address each of these topics. The TFGs are finishing their activity on 2017 and the content of this paper includes deliverables from these groups.
[The running status of Chinese Measles Laboratory Network in 2008].
Zhang, Yan; Xu, Song-Tao; Jiang, Xiao-Hong
2009-04-01
To evaluate the running status of Measles laboratory network of China (Hong Kong, Macao and Taiwan were excluded) in 2008. To analyze the database of Measles laboratory network surveillance of the year 2008, and the database of serologic and virologic surveillance of National laboratory for Measles in Chinese Centers for Disease Control and Prevention(CCDC), then the indicators of the running of Measles laboratory network of China were analyzed. 1, serologic surveillance: 107,160 Measles sera samples were collected between Feburary and September of 2008, and the collection rate was 77.93%; 53 778 samples were qualified and positive for IgM, the positive percentage was 50.2%. 2, Virologic surveillance: 287 Measles viral isolates were isolated by 18 provincial Measles laboratories in 2008, all were certified as H1a genotype, H1a genotype was still the predominant genotype circulating in China; 29 Rubella viral isolates were isolated by 4 provincial Measles laboratories in 2008, all belonged to 1E genotype. 3, Laboratory quality control: National laboratory for Measles passed the proficiency test and on-site review in 2008; all provincial Measles laboratories passed the sera samples recheck and proficiency test hold by National laboratory for Measles in 2008; Tianjin, Shanxi, Shandong, Zhejiang, Jilin, Hubei, provincial Measles laboratory passed the on-site review by WHO. The running status of Chinese Measles laboratory network was good in 2008, and good laboratory quality control system was also set up, methods such as specimens collection, serologic detection, cell culture and viral isolation, etc, were standardized, and applied to Chinese Measles laboratory network, and it provided important scientific basis for eradication Measles in the year of 2012.
Blaya, Joaquin A; Shin, Sonya S; Yagui, Martin J A; Yale, Gloria; Suarez, Carmen Z; Asencios, Luis L; Cegielski, J Peter; Fraser, Hamish S F
2007-10-28
Multi-drug resistant tuberculosis patients in resource-poor settings experience large delays in starting appropriate treatment and may not be monitored appropriately due to an overburdened laboratory system, delays in communication of results, and missing or error-prone laboratory data. The objective of this paper is to describe an electronic laboratory information system implemented to alleviate these problems and its expanding use by the Peruvian public sector, as well as examine the broader issues of implementing such systems in resource-poor settings. A web-based laboratory information system "e-Chasqui" has been designed and implemented in Peru to improve the timeliness and quality of laboratory data. It was deployed in the national TB laboratory, two regional laboratories and twelve pilot health centres. Using needs assessment and workflow analysis tools, e-Chasqui was designed to provide for improved patient care, increased quality control, and more efficient laboratory monitoring and reporting. Since its full implementation in March 2006, 29,944 smear microscopy, 31,797 culture and 7,675 drug susceptibility test results have been entered. Over 99% of these results have been viewed online by the health centres. High user satisfaction and heavy use have led to the expansion of e-Chasqui to additional institutions. In total, e-Chasqui will serve a network of institutions providing medical care for over 3.1 million people. The cost to maintain this system is approximately US$0.53 per sample or 1% of the National Peruvian TB program's 2006 budget. Electronic laboratory information systems have a large potential to improve patient care and public health monitoring in resource-poor settings. Some of the challenges faced in these settings, such as lack of trained personnel, limited transportation, and large coverage areas, are obstacles that a well-designed system can overcome. e-Chasqui has the potential to provide a national TB laboratory network in Peru. Furthermore, the core functionality of e-Chasqui as been implemented in the open source medical record system OpenMRS http://www.openmrs.org for other countries to use.
Blaya, Joaquin A; Shin, Sonya S; Yagui, Martin JA; Yale, Gloria; Suarez, Carmen Z; Asencios, Luis L; Cegielski, J Peter; Fraser, Hamish SF
2007-01-01
Background Multi-drug resistant tuberculosis patients in resource-poor settings experience large delays in starting appropriate treatment and may not be monitored appropriately due to an overburdened laboratory system, delays in communication of results, and missing or error-prone laboratory data. The objective of this paper is to describe an electronic laboratory information system implemented to alleviate these problems and its expanding use by the Peruvian public sector, as well as examine the broader issues of implementing such systems in resource-poor settings. Methods A web-based laboratory information system "e-Chasqui" has been designed and implemented in Peru to improve the timeliness and quality of laboratory data. It was deployed in the national TB laboratory, two regional laboratories and twelve pilot health centres. Using needs assessment and workflow analysis tools, e-Chasqui was designed to provide for improved patient care, increased quality control, and more efficient laboratory monitoring and reporting. Results Since its full implementation in March 2006, 29,944 smear microscopy, 31,797 culture and 7,675 drug susceptibility test results have been entered. Over 99% of these results have been viewed online by the health centres. High user satisfaction and heavy use have led to the expansion of e-Chasqui to additional institutions. In total, e-Chasqui will serve a network of institutions providing medical care for over 3.1 million people. The cost to maintain this system is approximately US$0.53 per sample or 1% of the National Peruvian TB program's 2006 budget. Conclusion Electronic laboratory information systems have a large potential to improve patient care and public health monitoring in resource-poor settings. Some of the challenges faced in these settings, such as lack of trained personnel, limited transportation, and large coverage areas, are obstacles that a well-designed system can overcome. e-Chasqui has the potential to provide a national TB laboratory network in Peru. Furthermore, the core functionality of e-Chasqui as been implemented in the open source medical record system OpenMRS for other countries to use. PMID:17963522
Roles of laboratories and laboratory systems in effective tuberculosis programmes
van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul
2007-01-01
Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219
Laboratory automation in a functional programming language.
Runciman, Colin; Clare, Amanda; Harkness, Rob
2014-12-01
After some years of use in academic and research settings, functional languages are starting to enter the mainstream as an alternative to more conventional programming languages. This article explores one way to use Haskell, a functional programming language, in the development of control programs for laboratory automation systems. We give code for an example system, discuss some programming concepts that we need for this example, and demonstrate how the use of functional programming allows us to express and verify properties of the resulting code. © 2014 Society for Laboratory Automation and Screening.
Duong, Veasna; Tarantola, Arnaud; Ong, Sivuth; Mey, Channa; Choeung, Rithy; Ly, Sowath; Bourhy, Hervé; Dussart, Philippe; Buchy, Philippe
2016-05-01
The diagnosis of dog-mediated rabies in humans and animals has greatly benefited from technical advances in the laboratory setting. Approaches to diagnosis now include the detection of rabies virus (RABV), RABV RNA, or RABV antigens. These assays are important tools in the current efforts aimed at the global elimination of dog-mediated rabies. The assays available for use in laboratories are reviewed herein, as well as their strengths and weaknesses, which vary with the types of sample analyzed. Depending on the setting, however, the public health objectives and use of RABV diagnosis in the field will also vary. In non-endemic settings, the detection of all introduced or emergent animal or human cases justifies exhaustive testing. In dog RABV-endemic settings, such as rural areas of developing countries where most cases occur, the availability of or access to testing may be severely constrained. Thus, these issues are also discussed along with a proposed strategy to prioritize testing while access to rabies testing in the resource-poor, highly endemic setting is improved. As the epidemiological situation of rabies in a country evolves, the strategy should shift from that of an endemic setting to one more suitable for a decreased rabies incidence following the implementation of efficient control measures and when nearing the target of dog-mediated rabies elimination. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Controlling Laboratory Processes From A Personal Computer
NASA Technical Reports Server (NTRS)
Will, H.; Mackin, M. A.
1991-01-01
Computer program provides natural-language process control from IBM PC or compatible computer. Sets up process-control system that either runs without operator or run by workers who have limited programming skills. Includes three smaller programs. Two of them, written in FORTRAN 77, record data and control research processes. Third program, written in Pascal, generates FORTRAN subroutines used by other two programs to identify user commands with device-driving routines written by user. Also includes set of input data allowing user to define user commands to be executed by computer. Requires personal computer operating under MS-DOS with suitable hardware interfaces to all controlled devices. Also requires FORTRAN 77 compiler and device drivers written by user.
A Radiation Laboratory Curriculum Development at Western Kentucky University
NASA Astrophysics Data System (ADS)
Barzilov, Alexander P.; Novikov, Ivan S.; Womble, Phil C.
2009-03-01
We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is to develop a set of radiation laboratories, which will strengthen the curriculum of physics, chemistry, geology, biology, and environmental science at WKU. The teaching and research activities are integrated into real-world projects and hands-on activities to engage students. The proposed experiments and their relevance to the modern status of physical science are discussed.
TACS Central Control Facility.
1981-02-12
PULSE RTC REAL TIME CLOCK -{> I . SIGNAL INVERSION UASC UNIVERSAL ASYNCHRONOUS SERIAL - ---- 4w SPECIAL INTERFACE CONTROLLER Fiq. 2-1. MAC hardware...34 Universal Asynchronous Serial Controller" (UASC) cards. The cards implement an RS-232 standard interface. All controllers are set to operate at a data...Bridwell and I. Richer, "A Preliminary Design of a TDMA System for FLEETSAT," Technical Note 1975-5, Lincoln Laboratory, M.I.T. (12 March 1975), DDC
Jayakody, Chatura; Hull-Ryde, Emily A
2016-01-01
Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.
Integrated Energy Solutions | NREL
Transitions A man and woman standing in front of a large, color 3D visualization screen that spans the height a woman and a man testing a scaled model of a microgrid controller in a laboratory setting
ROANOKE WOODSTOVE EMISSION TESTS
The report discusses a project, part of the Integrated Air Cancer Project Roanoke study, that characterizes and quantifies emissions generated by burning authentic Roanoke cordwood. The burning occurred in a controlled laboratory setting using two woodstoves, each operated at two...
Robinson, Eric; Hardman, Charlotte A; Halford, Jason C G; Jones, Andrew
2015-08-01
Laboratory paradigms are commonly used to study human energy intake. However, the extent to which participants believe their eating behavior is being measured may affect energy intake and is a methodologic factor that has received little consideration. Our main objective was to examine available evidence for the effect that heightened awareness of observation has on energy intake in a laboratory setting. We systematically reviewed laboratory studies that allowed for experimental examination of the effect that heightened awareness of observation has on energy intake. From these experimental studies we combined effect estimates using inverse variance meta-analysis, calculating the standardized mean difference (SMD) in energy intake between heightened-awareness and control conditions and qualitatively synthesized potential moderators of this effect. Nine studies, providing 22 comparisons, were eligible for inclusion. These studies largely sampled young women and examined the energy intake of energy-dense snack foods. Evidence indicated that heightened awareness of observation was associated with reduced energy intake when compared with the control condition (random-effects SMD: 0.45; 95% CI: 0.25, 0.66; P < 0.0001). We found little evidence that the type of experimental manipulation used to heighten awareness moderated the overall effect. The available evidence to date suggests that heightened awareness of observation reduces energy intake in a laboratory setting. These findings suggest that laboratory studies should attempt to minimize the degree to which participants are aware that their eating behavior is being measured. © 2015 American Society for Nutrition.
Maui Space Surveillance System Satellite Categorization Laboratory
NASA Astrophysics Data System (ADS)
Deiotte, R.; Guyote, M.; Kelecy, T.; Hall, D.; Africano, J.; Kervin, P.
The MSSS satellite categorization laboratory is a fusion of robotics and digital imaging processes that aims to decompose satellite photometric characteristics and behavior in a controlled setting. By combining a robot, light source and camera to acquire non-resolved images of a model satellite, detailed photometric analyses can be performed to extract relevant information about shape features, elemental makeup, and ultimately attitude and function. Using the laboratory setting a detailed analysis can be done on any type of material or design and the results cataloged in a database that will facilitate object identification by "curve-fitting" individual elements in the basis set to observational data that might otherwise be unidentifiable. Currently the laboratory has created, an ST-Robotics five degree of freedom robotic arm, collimated light source and non-focused Apogee camera have all been integrated into a MATLAB based software package that facilitates automatic data acquisition and analysis. Efforts to date have been aimed at construction of the lab as well as validation and verification of simple geometric objects. Simple tests on spheres, cubes and simple satellites show promising results that could lead to a much better understanding of non-resolvable space object characteristics. This paper presents a description of the laboratory configuration and validation test results with emphasis on the non-resolved photometric characteristics for a variety of object shapes, spin dynamics and orientations. The future vision, utility and benefits of the laboratory to the SSA community as a whole are also discussed.
Kruger, Tillmann H C; Deiter, Frank; Zhang, Yuanyuan; Jung, Stefanie; Schippert, Cordula; Kahl, Kai G; Heinrichs, Markus; Schedlowski, Manfred; Hartmann, Uwe
2018-06-01
The neuropeptide oxytocin (OXT) has a variety of physiological functions in maternal behavior and attachment including sexual behavior. Based on animal research and our previous human studies, we set out to investigate intranasal administration of OXT and hypothesized that OXT should be able to modulate sexual function in women. In a double-blind, placebo-controlled, crossover laboratory setting, the acute effects of intranasal administered OXT (24 international units) on sexual drive, arousal, orgasm, and refractory aspects of sexual behavior were analyzed in 27 healthy females (mean age ± SD, 27.52 ± 8.04) together with physiological parameters using vaginal photoplethysmography. Oxytocin administration showed no effect on subjective sexual parameters (eg, postorgasmic tension; P = 0.051). Physiological parameters (vaginal photoplethysmography amplitude and vaginal blood volume) showed a response pattern towards sexual arousal but were not affected by OXT. Using a well-established laboratory paradigm, we did not find that intranasal OXT influences female sexual parameters. Also, sexual drive and other functions were not affected by OXT. These findings indicate that OXT is not able to significantly increase subjective and objective parameters of sexual function in a setting with high internal validity; however, this might be different in a more naturalistic setting.
Kiley, Kasey B.; Haywood, Carlton; Bediako, Shawn M.; Lanzkron, Sophie; Carroll, C. Patrick; Buenaver, Luis F.; Pejsa, Megan; Edwards, Robert R.; Haythornthwaite, Jennifer A.; Campbell, Claudia M.
2016-01-01
Objective: People living with sickle cell disease (SCD) experience severe episodic and chronic pain and frequently report poor interpersonal treatment within health-care settings. In this particularly relevant context, we examined the relationship between perceived discrimination and both clinical and laboratory pain. Methods: Seventy-one individuals with SCD provided self-reports of experiences with discrimination in health-care settings and clinical pain severity, and completed a psychophysical pain testing battery in the laboratory. Results: Discrimination in health-care settings was correlated with greater clinical pain severity and enhanced sensitivity to multiple laboratory-induced pain measures, as well as stress, depression, and sleep. After controlling for relevant covariates, discrimination remained a significant predictor of mechanical temporal summation (a marker of central pain facilitation), but not clinical pain severity or suprathreshold heat pain response. Furthermore, a significant interaction between experience with discrimination and clinical pain severity was associated with mechanical temporal summation; increased experience with discrimination was associated with an increased correlation between clinical pain severity and temporal summation of pain. Discussion: Perceived discrimination within health-care settings was associated with pain facilitation. These findings suggest that discrimination may be related to increased central sensitization among SCD patients, and more broadly that health-care social environments may interact with pain pathophysiology. PMID:26889615
Design principles of a cooperative robot controller
NASA Technical Reports Server (NTRS)
Hayward, Vincent; Hayati, Samad
1987-01-01
The paper describes the design of a controller for cooperative robots being designed at McGill University in a collaborative effort with the Jet Propulsion Laboratory. The first part of the paper discusses the background and motivation for multiple arm control. Then, a set of programming primitives, which are based on the RCCL system and which permit a programmer to specify cooperative tasks are described. The first group of primitives are motion primitives which specify asynchronous motions, master/slave motions, and cooperative motions. In the context of cooperative robots, trajectory generation issues will be discussed and the implementation described. A second set of primitives provides for the specification of spatial relationships. The relations between programming and control in the case of multiple robot are examined. Finally, the paper describes the allocation of various tasks among a set of microprocessors sharing a common bus.
Turton, Jane F; Wright, Laura; Underwood, Anthony; Witney, Adam A; Chan, Yuen-Ting; Al-Shahib, Ali; Arnold, Catherine; Doumith, Michel; Patel, Bharat; Planche, Timothy D; Green, Jonathan; Holliman, Richard; Woodford, Neil
2015-08-01
Whole-genome sequencing (WGS) was carried out on 87 isolates of sequence type 111 (ST-111) of Pseudomonas aeruginosa collected between 2005 and 2014 from 65 patients and 12 environmental isolates from 24 hospital laboratories across the United Kingdom on an Illumina HiSeq instrument. Most isolates (73) carried VIM-2, but others carried IMP-1 or IMP-13 (5) or NDM-1 (1); one isolate had VIM-2 and IMP-18, and 7 carried no metallo-beta-lactamase (MBL) gene. Single nucleotide polymorphism analysis divided the isolates into distinct clusters; the NDM-1 isolate was an outlier, and the IMP isolates and 6/7 MBL-negative isolates clustered separately from the main set of 73 VIM-2 isolates. Within the VIM-2 set, there were at least 3 distinct clusters, including a tightly clustered set of isolates from 3 hospital laboratories consistent with an outbreak from a single introduction that was quickly brought under control and a much broader set dominated by isolates from a long-running outbreak in a London hospital likely seeded from an environmental source, requiring different control measures; isolates from 7 other hospital laboratories in London and southeast England were also included. Bayesian evolutionary analysis indicated that all the isolates shared a common ancestor dating back ∼50 years (1960s), with the main VIM-2 set separating approximately 20 to 30 years ago. Accessory gene profiling revealed blocks of genes associated with particular clusters, with some having high similarity (≥95%) to bacteriophage genes. WGS of widely found international lineages such as ST-111 provides the necessary resolution to inform epidemiological investigations and intervention policies. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Toward Active Control of Noise from Hot Supersonic Jets
2013-11-15
several laboratory - and full- scale data sets. Two different scaling scenarios are presented for the practising scientist to choose from. The first...As will be detailed below, this simple proof-of-concept experiment yielded good quality data that reveals details about the large-scale 3D structure...the light-field. Co-PI Thurow has recently designed and assembled a plenoptic camera in his laboratory with its key attributes being its compact
Miraglia, Caterina M
2016-12-01
The purpose of this paper is to review information regarding the current guidelines for the clinical laboratory diagnosis of Lyme disease as set forth by the Centers for Disease Control and Prevention (CDC) to chiropractic physicians and to discuss the clinical utility of this testing. The CDC's website was reviewed to determine what their current recommendations are for the clinical laboratory testing of Lyme disease. The CDC's established guidelines recommend the use of a 2-tiered serologic testing algorithm for the evaluation of patients with suspected Lyme disease. This review provides doctors of chiropractic with information to remain current with the CDC's recommended guidelines for Lyme disease testing because patients may present to their office with the associated signs and symptoms of Lyme disease.
Multi-mode evaluation of power-maximizing cross-flow turbine controllers
Forbush, Dominic; Cavagnaro, Robert J.; Donegan, James; ...
2017-09-21
A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performancemore » at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.« less
Multi-mode evaluation of power-maximizing cross-flow turbine controllers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forbush, Dominic; Cavagnaro, Robert J.; Donegan, James
A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performancemore » at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.« less
Hennekinne, Jacques-Antoine; Gohier, Martine; Maire, Tiphaine; Lapeyre, Christiane; Lombard, Bertrand; Dragacci, Sylviane
2003-01-01
The European Commission has designed a network of European Union-National Reference Laboratories (EU-NRLs), coordinated by a Community Reference Laboratory (CRL), for control of hygiene of milk and milk products (Council Directive 92/46/ECC). As a common contaminant of milk and milk products such as cheese, staphylococcal enterotoxins are often involved in human outbreaks and should be monitored regularly. The main tasks of the EU-CRLs were to select and transfer to the EU-NRLs a reference method for detection of enterotoxins, and to set up proficiency testing to evaluate the competency of the European laboratory network. The first interlaboratory exercise was performed on samples of freeze-dried cheese inoculated with 2 levels of staphylococcal enterotoxins (0.1 and 0.25 ng/g) and on an uninoculated control. These levels were chosen considering the EU regulation for staphylococcal enterotoxins in milk and milk products and the limit of detection of the enzyme-linked immunosorbent assay test recommended in the reference method. The trial was conducted according to the recommendations of ISO Guide 43. Results produced by laboratories were compiled and compared through statistical analysis. Except for data from 2 laboratories for the uninoculated control and cheese inoculated at 0.1 ng/g, all laboratories produced satisfactory results, showing the ability of the EU-NRL network to monitor the enterotoxin contaminant.
Multisite Evaluation of Point of Care CD4 Testing in Papua New Guinea
Malagun, Malin; Nano, Gideon; Chevallier, Caroline; Opina, Ragagalo; Sawiya, Gola; Kivavia, Joseph; Kalinoe, Albina; Nathaniel, Kathalina; Kaminiel, Oscillah; Millan, John; Carmone, Andrea; Dini, Mary; Palou, Theresa; Topma, Kum; Lavu, Evelyn; Markby, Jessica
2014-01-01
Laboratory-based CD4 monitoring of HIV patients presents challenges in resource limited settings (RLS) including frequent machine breakdown, poor engineering support and limited cold chain and specimen transport logistics. This study assessed the performance of two CD4 tests designed for use in RLS; the Dynal assay and the Alere PIMA test (PIMA). Accuracy of Dynal and PIMA using venous blood was assessed in a centralised laboratory by comparison to BD FACSCount (BD FACS). Dynal had a mean bias of −50.35 cells/µl (r2 = 0.973, p<0.0001, n = 101) and PIMA −22.43 cells/µl (r2 = 0.964, p<0.0001, n = 139) compared to BD FACS. Similar results were observed for PIMA operated by clinicians in one urban (n = 117) and two rural clinics (n = 98). Using internal control beads, PIMA precision was 10.34% CV (low bead mean 214.24 cells/µl) and 8.29% (high bead mean 920.73 cells/µl) and similar %CV results were observed external quality assurance (EQA) and replicate patient samples. Dynal did not perform using EQA and no internal controls are supplied by the manufacturer, however duplicate testing of samples resulted in r2 = 0.961, p<0.0001, mean bias = −1.44 cells/µl. Using the cut-off of 350 cells/µl compared to BD FACS, PIMA had a sensitivity of 88.85% and specificity of 98.71% and Dynal 88.61% and 100%. A total of 0.44% (2/452) of patient samples were misclassified as “no treat” and 7.30% (33/452) “treat” using PIMA whereas with Dynal 8.91% (9/101) as “treat” and 0% as “no treat”. In our setting PIMA was found to be accurate, precise and user-friendly in both laboratory and clinic settings. Dynal performed well in initial centralized laboratory evaluation, however lacks requisite quality control measures, and was technically more difficult to use, making it less suitable for use at lower tiered laboratories. PMID:25426710
Zamora, D; Torres, A
2014-01-01
Reliable estimations of the evolution of water quality parameters by using in situ technologies make it possible to follow the operation of a wastewater treatment plant (WWTP), as well as improving the understanding and control of the operation, especially in the detection of disturbances. However, ultraviolet (UV)-Vis sensors have to be calibrated by means of a local fingerprint laboratory reference concentration-value data-set. The detection of outliers in these data-sets is therefore important. This paper presents a method for detecting outliers in UV-Vis absorbances coupled to water quality reference laboratory concentrations for samples used for calibration purposes. Application to samples from the influent of the San Fernando WWTP (Medellín, Colombia) is shown. After the removal of outliers, improvements in the predictability of the influent concentrations using absorbance spectra were found.
NASA Technical Reports Server (NTRS)
Vogl, J. L.
1973-01-01
Current work aimed at identifying the active magnetospheric experiments that can be performed from the Space Shuttle, and designing a laboratory to carry out these experiments is described. The laboratory, known as the PPEPL (Plasma Physics and Environmental Perturbation Laboratory) consists of 35-ft pallet of instruments connected to a 25-ft pressurized control module. The systems deployed from the pallet are two 50-m booms, two subsatellites, a high-power transmitter, a multipurpose accelerator, a set of deployable canisters, and a gimbaled instrument platform. Missions are planned to last seven days, during which two scientists will carry out experiments from within the pressurized module. The type of experiments to be performed are outlined.
Hornish, Rex E; Hamlow, Philip J; Brown, Scott A
2003-01-01
A multilaboratory trial for determining ceftiofur-related residues in bovine and swine kidney and muscle, and bovine milk was conducted following regulatory guidelines of the U.S. Food and Drug Administration, Center for Veterinary Medicine. The methods convert all desfuroylceftiofur-related residues containing the intact beta-lactam ring to desfuroylceftiofur acetamide to establish ceftiofur residues in tissues. Four laboratories analyzed 5 sets of samples for each tissue. Each sample set consisted of a control/blank sample and 3 control samples fortified with ceftiofur at 0.5 Rm, Rm, and 2 Rm, respectively, where Rm is the U.S. tolerance assigned for ceftiofur residue in each tissue/matrix: 0.100 microg/mL for milk, 8.0 microg/g for kidney (both species), 1.0 microg/g for bovine muscle, and 2.0 microg/g for swine muscle. Each sample set also contained 2 samples of incurred-residue tissues (one > Rm and one < Rm) from animals treated with ceftiofur hydrochloride. All laboratories completed the method trial after a familiarization phase and test of system suitability in which they demonstrated > 80% recovery in pretrial fortified test samples. Results showed that the methods met all acceptable performance criteria for recovery, accuracy, and precision. Although sample preparation was easy, solid-phase extraction cartridge performance must be carefully evaluated before samples are processed. The liquid chromatography detection system was easily set up; however, the elution profile may require slight modifications. The procedures could clearly differentiate between violative (> Rm) and nonviolative (< Rm) ceftiofur residues. Participating laboratories found the procedures suitable for ceftiofur residue determination.
Terrain Characterization for Trafficability
1993-06-01
pensive and less time-consuming. Although carefully raphy, on vehicle operation. This report focuses on the controlled laboratory tests may be more...relating indentation to soil strength. on a portable test rig or on an off-road vehicle where it A series of controlled experiments to determine the is... Controls and setting values for hydraulic pressures and flow Figure 10. Wheel are test rig (after Wasterhund 1990). 7 Vertical Proximity L ock-Oit~u
Slew maneuvers of Spacecraft Control Laboratory Experiment (SCOLE)
NASA Technical Reports Server (NTRS)
Kakad, Yogendra P.
1992-01-01
This is the final report on the dynamics and control of slew maneuvers of the Spacecraft Control Laboratory Experiment (SCOLE) test facility. The report documents the basic dynamical equation derivations for an arbitrary large angle slew maneuver as well as the basic decentralized slew maneuver control algorithm. The set of dynamical equations incorporate rigid body slew maneuver and three dimensional vibrations of the complete assembly comprising the rigid shuttle, the flexible beam, and the reflector with an offset mass. The analysis also includes kinematic nonlinearities of the entire assembly during the maneuver and the dynamics of the interactions between the rigid shuttle and the flexible appendage. The equations are simplified and evaluated numerically to include the first ten flexible modes to yield a model for designing control systems to perform slew maneuvers. The control problem incorporates the nonlinear dynamical equations and is expressed in terms of a two point boundary value problem.
A comparison of two microscale laboratory reporting methods in a secondary chemistry classroom
NASA Astrophysics Data System (ADS)
Martinez, Lance Michael
This study attempted to determine if there was a difference between the laboratory achievement of students who used a modified reporting method and those who used traditional laboratory reporting. The study also determined the relationships between laboratory performance scores and the independent variables score on the Group Assessment of Logical Thinking (GALT) test, chronological age in months, gender, and ethnicity for each of the treatment groups. The study was conducted using 113 high school students who were enrolled in first-year general chemistry classes at Pueblo South High School in Colorado. The research design used was the quasi-experimental Nonequivalent Control Group Design. The statistical treatment consisted of the Multiple Regression Analysis and the Analysis of Covariance. Based on the GALT, students in the two groups were generally in the concrete and transitional stages of the Piagetian cognitive levels. The findings of the study revealed that the traditional and the modified methods of laboratory reporting did not have any effect on the laboratory performance outcome of the subjects. However, the students who used the traditional method of reporting showed a higher laboratory performance score when evaluation was conducted using the New Standards rubric recommended by the state. Multiple Regression Analysis revealed that there was a significant relationship between the criterion variable student laboratory performance outcome of individuals who employed traditional laboratory reporting methods and the composite set of predictor variables. On the contrary, there was no significant relationship between the criterion variable student laboratory performance outcome of individuals who employed modified laboratory reporting methods and the composite set of predictor variables.
Antinuclear antibody determination in a routine laboratory.
Feltkamp, T E
1996-01-01
Pitfalls in the method for demonstrating antinuclear antibodies (ANA) by the indirect immunofluorescence technique are described and the use of international standard preparations outlined. Determination of the optimal border dilution dividing positive from negative results is discussed. Each laboratory is a unique setting; it must define its own method, which should rarely be changed. One should not rely on copying methods from other laboratories or commercial firms, but the reproducibility of the nuclear substrate, the conjugate, and other variables should be controlled daily by the use of a control serum which has been related to the WHO standard preparation for ANA of the homogeneous type. Since many sera contain mixtures of different ANA, the results of routine tests are best expressed in titres or expressions of the intensity of fluorescence. The ANA test using the immunofluorescence technique should be used as a screening method for other tests allowing a more defined interpretation of the ANA. Each laboratory should individually determine the border between positive and negative results. Therefore about 200 sera from local healthy controls equally distributed over sex and age, and 100 sera from local patients with definite SLE should be tested. Since the local clinicians should become acquainted with this border it should rarely be changed. Finally each laboratory should participate regularly in national and international quality control rounds, where sera known to be difficult to interpret are tested. The judgment of the organisers of these rounds should stimulate improvements in the participating laboratories. PMID:8984936
Nkengasong, John N; Mesele, Tsehaynesh; Orloff, Sherry; Kebede, Yenew; Fonjungo, Peter N; Timperi, Ralph; Birx, Deborah
2009-06-01
Medical laboratory services are an essential, yet often neglected, component of health systems in developing countries. Their central role in public health, disease control and surveillance, and patient management is often poorly recognized by governments and donors. However, medical laboratory services in developing countries can be strengthened by leveraging funding from other sources of HIV/AIDS prevention, care, surveillance, and treatment programs. Strengthening these services will require coordinated efforts by national governments and partners and can be achieved by establishing and implementing national laboratory strategic plans and policies that integrate laboratory systems to combat major infectious diseases. These plans should take into account policy, legal, and regulatory frameworks; the administrative and technical management structure of the laboratories; human resources and retention strategies; laboratory quality management systems; monitoring and evaluation systems; procurement and maintenance of equipment; and laboratory infrastructure enhancement. Several countries have developed or are in the process of developing their laboratory plans, and others, such as Ethiopia, have implemented and evaluated their plan.
Optimal Sparse Upstream Sensor Placement for Hydrokinetic Turbines
NASA Astrophysics Data System (ADS)
Cavagnaro, Robert; Strom, Benjamin; Ross, Hannah; Hill, Craig; Polagye, Brian
2016-11-01
Accurate measurement of the flow field incident upon a hydrokinetic turbine is critical for performance evaluation during testing and setting boundary conditions in simulation. Additionally, turbine controllers may leverage real-time flow measurements. Particle image velocimetry (PIV) is capable of rendering a flow field over a wide spatial domain in a controlled, laboratory environment. However, PIV's lack of suitability for natural marine environments, high cost, and intensive post-processing diminish its potential for control applications. Conversely, sensors such as acoustic Doppler velocimeters (ADVs), are designed for field deployment and real-time measurement, but over a small spatial domain. Sparsity-promoting regression analysis such as LASSO is utilized to improve the efficacy of point measurements for real-time applications by determining optimal spatial placement for a small number of ADVs using a training set of PIV velocity fields and turbine data. The study is conducted in a flume (0.8 m2 cross-sectional area, 1 m/s flow) with laboratory-scale axial and cross-flow turbines. Predicted turbine performance utilizing the optimal sparse sensor network and associated regression model is compared to actual performance with corresponding PIV measurements.
Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo
2015-01-01
To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.
Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun
2015-01-01
Introduction To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. Materials and methods 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. Results The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Conclusions Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them. PMID:26110033
Progress in the development of paper-based diagnostics for low-resource point-of-care settings
Byrnes, Samantha; Thiessen, Gregory; Fu, Elain
2014-01-01
This Review focuses on recent work in the field of paper microfluidics that specifically addresses the goal of translating the multistep processes that are characteristic of gold-standard laboratory tests to low-resource point-of-care settings. A major challenge is to implement multistep processes with the robust fluid control required to achieve the necessary sensitivity and specificity of a given application in a user-friendly package that minimizes equipment. We review key work in the areas of fluidic controls for automation in paper-based devices, readout methods that minimize dedicated equipment, and power and heating methods that are compatible with low-resource point-of-care settings. We also highlight a focused set of recent applications and discuss future challenges. PMID:24256361
Hyvärinen, A
1985-01-01
The main purpose of the present study was to describe the statistical behaviour of daily analytical errors in the dimensions of place and time, providing a statistical basis for realistic estimates of the analytical error, and hence allowing the importance of the error and the relative contributions of its different sources to be re-evaluated. The observation material consists of creatinine and glucose results for control sera measured in daily routine quality control in five laboratories for a period of one year. The observation data were processed and computed by means of an automated data processing system. Graphic representations of time series of daily observations, as well as their means and dispersion limits when grouped over various time intervals, were investigated. For partition of the total variation several two-way analyses of variance were done with laboratory and various time classifications as factors. Pooled sets of observations were tested for normality of distribution and for consistency of variances, and the distribution characteristics of error variation in different categories of place and time were compared. Errors were found from the time series to vary typically between days. Due to irregular fluctuations in general and particular seasonal effects in creatinine, stable estimates of means or of dispersions for errors in individual laboratories could not be easily obtained over short periods of time but only from data sets pooled over long intervals (preferably at least one year). Pooled estimates of proportions of intralaboratory variation were relatively low (less than 33%) when the variation was pooled within days. However, when the variation was pooled over longer intervals this proportion increased considerably, even to a maximum of 89-98% (95-98% in each method category) when an outlying laboratory in glucose was omitted, with a concomitant decrease in the interaction component (representing laboratory-dependent variation with time). This indicates that a substantial part of the variation comes from intralaboratory variation with time rather than from constant interlaboratory differences. Normality and consistency of statistical distributions were best achieved in the long-term intralaboratory sets of the data, under which conditions the statistical estimates of error variability were also most characteristic of the individual laboratories rather than necessarily being similar to one another. Mixing of data from different laboratories may give heterogeneous and nonparametric distributions and hence is not advisable.(ABSTRACT TRUNCATED AT 400 WORDS)
Toward laboratory torsional spine magnetic reconnection
NASA Astrophysics Data System (ADS)
Chesny, David L.; Orange, N. Brice; Oluseyi, Hakeem M.; Valletta, David R.
2017-12-01
Magnetic reconnection is a fundamental energy conversion mechanism in nature. Major attempts to study this process in controlled settings on Earth have largely been limited to reproducing approximately two-dimensional (2-D) reconnection dynamics. Other experiments describing reconnection near three-dimensional null points are non-driven, and do not induce any of the 3-D modes of spine fan, torsional fan or torsional spine reconnection. In order to study these important 3-D modes observed in astrophysical plasmas (e.g. the solar atmosphere), laboratory set-ups must be designed to induce driven reconnection about an isolated magnetic null point. As such, we consider the limited range of fundamental resistive magnetohydrodynamic (MHD) and kinetic parameters of dynamic laboratory plasmas that are necessary to induce the torsional spine reconnection (TSR) mode characterized by a driven rotational slippage of field lines - a feature that has yet to be achieved in operational laboratory magnetic reconnection experiments. Leveraging existing reconnection models, we show that within a 3$ apparatus, TSR can be achieved in dense plasma regimes ( 24~\\text{m}-3$ ) in magnetic fields of -1~\\text{T}$ . We find that MHD and kinetic parameters predict reconnection in thin current sheets on time scales of . While these plasma regimes may not explicitly replicate the plasma parameters of observed astrophysical phenomena, studying the dynamics of the TSR mode within achievable set-ups signifies an important step in understanding the fundamentals of driven 3-D magnetic reconnection and the self-organization of current sheets. Explicit control of this reconnection mode may have implications for understanding particle acceleration in astrophysical environments, and may even have practical applications to fields such as spacecraft propulsion.
Giannoli, Jean-Marc; Szymanowicz, Anton
2011-01-01
We propose a set of recommendations and practices to optimize the use of quality control of medical biology examinations. The fundamentals are reviewed: definition of a series of analysis, IQC at one or more level, Westgard alert rules and rejection, practical remedial actions to take for the technician, corrective and preventive actions to be implemented by the biologist. We have also formalized three flowcharts to guide the technician in their daily practice to ensure analytical quality of investigations carried out. These decision trees are the result of the experience submitted by an accredited and professional laboratory attentive to the ongoing improvement of IQC. This article can provide useful assistance to biologists for accreditation but also aims to foster collaboration reliable medical biology laboratory at the appropriate management of patients.
NASA Astrophysics Data System (ADS)
Ovchinnikov, M. Yu.; Ivanov, D. S.; Ivlev, N. A.; Karpenko, S. O.; Roldugin, D. S.; Tkachev, S. S.
2014-01-01
Design, analytical investigation, laboratory and in-flight testing of the attitude determination and control system (ADCS) of a microsatellites are considered. The system consists of three pairs of reaction wheels, three magnetorquers, a set of Sun sensors, a three-axis magnetometer and a control unit. The ADCS is designed for a small 10-50 kg LEO satellite. System development is accomplished in several steps: satellite dynamics preliminary study using asymptotical and numerical techniques, hardware and software design, laboratory testing of each actuator and sensor and the whole ADCS. Laboratory verification is carried out on the specially designed test-bench. In-flight ADCS exploitation results onboard the Russian microsatellite "Chibis-M" are presented. The satellite was developed, designed and manufactured by the Institute of Space Research of RAS. "Chibis-M" was launched by the "Progress-13M" cargo vehicle on January 25, 2012 after undocking from the International Space Station (ISS). This paper assess both the satellite and the ADCS mock-up dynamics. Analytical, numerical and laboratory study results are in good correspondence with in-flight data.
Capraro, Valerio; Cococcioni, Giorgia
2015-01-01
Recent studies suggest that cooperative decision-making in one-shot interactions is a history-dependent dynamic process: promoting intuition versus deliberation typically has a positive effect on cooperation (dynamism) among people living in a cooperative setting and with no previous experience in economic games on cooperation (history dependence). Here, we report on a laboratory experiment exploring how these findings transfer to a non-cooperative setting. We find two major results: (i) promoting intuition versus deliberation has no effect on cooperative behaviour among inexperienced subjects living in a non-cooperative setting; (ii) experienced subjects cooperate more than inexperienced subjects, but only under time pressure. These results suggest that cooperation is a learning process, rather than an instinctive impulse or a self-controlled choice, and that experience operates primarily via the channel of intuition. Our findings shed further light on the cognitive basis of human cooperative decision-making and provide further support for the recently proposed social heuristics hypothesis. PMID:26156762
Effect of a laboratory result pager on provider behavior in a neonatal intensive care unit.
Samal, L; Stavroudis, Ta; Miller, Re; Lehmann, Hp; Lehmann, Cu
2011-01-01
A computerized laboratory result paging system (LRPS) that alerts providers about abnormal results ("push") may improve upon active laboratory result review ("pull"). However, implementing such a system in the intensive care setting may be hindered by low signal-to-noise ratio, which may lead to alert fatigue. To evaluate the impact of an LRPS in a Neonatal Intensive Care Unit. Utilizing paper chart review, we tallied provider orders following an abnormal laboratory result before and after implementation of an LRPS. Orders were compared with a predefined set of appropriate orders for such an abnormal result. The likelihood of a provider response in the post-implementation period as compared to the pre-implementation period was analyzed using logistic regression. The provider responses were analyzed using logistic regression to control for potential confounders. The likelihood of a provider response to an abnormal laboratory result did not change significantly after implementation of an LRPS. (Odds Ratio 0.90, 95% CI 0.63-1.30, p-value 0.58) However, when providers did respond to an alert, the type of response was different. The proportion of repeat laboratory tests increased. (26/378 vs. 7/278, p-value = 0.02). Although the laboratory result pager altered healthcare provider behavior in the Neonatal Intensive Care Unit, it did not increase the overall likelihood of provider response.
[Medical safety in infectious disease--chairmen's introductory remarks].
Shimetani, Naoto; Miida, Takashi
2012-10-01
"The National Joint Action of Risk Management" was started in May 2008. The Japanese Society of Laboratory Medicine took this opportunity to set up a Medical Safety Committee as a participant in this Action. The Society holds symposia concerning medical safety to educate the Society members. Nosocomial infections are medical accidents. Whereas community-acquired infections are likely to develop depending on a balance between pathogens and hosts, nosocomial infections are implicated with medical practices, so they develop depending on the interrelationship among pathogens, hosts, and medical practices. Medical practices are mostly indispensable for providing medical services; therefore, activities against nosocomial infections are critical for establishing medical safety, freedom from anxiety, and reliability. Hence, this symposium deals with five themes: Countermeasures against and the management of needle-stick and cut accidents, collaboration between the infection control team (ICT) and the bacteriology laboratory, information transmission from the clinical laboratory department to physicians engaged in infectious disease treatment, utilization of laboratory data for infection control, and medical safety against tuberculosis infection.
Outbreaks in Health Care Settings.
Sood, Geeta; Perl, Trish M
2016-09-01
Outbreaks and pseudo-outbreaks in health care settings can be complex and should be evaluated systematically using epidemiologic tools. Laboratory testing is an important part of an outbreak evaluation. Health care personnel, equipment, supplies, water, ventilation systems, and the hospital environment have been associated with health care outbreaks. Settings including the neonatal intensive care unit, endoscopy, oncology, and transplant units are areas that have specific issues which impact the approach to outbreak investigation and control. Certain organisms have a predilection for health care settings because of the illnesses of patients, the procedures performed, and the care provided. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Gordon, Robert W.; Ozguner, Umit; Yurkovich, Steven
1989-01-01
The Flight Dynamics Laboratory is committed to an in-house, experimental investigation of several technical areas critical to the dynamic performance of future Air Force large space structures. The advanced beam experiment was successfully completed and provided much experience in the implementation of active control approaches on real hardware. A series of experiments is under way in evaluating ground test methods on the 12 meter trusses with significant passive damping. Ground simulated zero-g response data from the undamped truss will be compared directly with true zero-g flight test data. The performance of several leading active control approaches will be measured and compared on one of the trusses in the presence of significant passive damping. In the future, the PACOSS dynamic test article will be set up as a test bed for the evaluation of system identification and control techniques on a complex, representative structure with high modal density and significant passive damping.
The office laboratory. A boon to your practice? Or a burden?
Kroger, J S
1987-05-01
Many primary care physicians are finding it convenient and productive to set up their own office laboratories. Such on-site labs answer many needs, but there are also potential drawbacks. All the pros and cons involved in such a venture are described: Increased efficiency in patient care may be counterbalanced by the irritation generated by reimbursement control and governmental regulation. For those who wish to proceed with this project, the author offers sound step-by-step advice.
Development of a quality assurance program for ionizing radiation secondary calibration laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heaton, H.T. II; Taylor, A.R. Jr.
For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. Thismore » paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory.« less
Quality and rural-urban comparison of tuberculosis care in Rivers State, Nigeria.
Tobin-West, Charles Ibiene; Isodje, Anastasia
2016-01-01
Nigeria ranks among countries with the highest burden of tuberculosis. Yet evidence continues to indicate poor treatment outcomes which have been attributed to poor quality of care. This study aims to identify some of the systemic problems in order to inform policy decisions for improved quality of services and treatment outcomes in Nigeria. A comparative assessment of the quality of TB care in rural and urban health facilities was carried out between May and June 2013, employing the Donabedian model of quality assessment. Data was analysed using the SPSS software package version 20.0. The level of significance was set at p < 0.05. Health facility infrastructures were more constrained in the urban than rural settings. Both the urban and rural facilities lacked adequate facilities for infection control such as, running water, air filter respirators, hand gloves and extractor fans. Health education and HIV counselling and testing (HCT) were limited in rural facilities compared to urban facilities. Although anti-TB drugs were generally available in both settings, the DOTS strategy in patient care was completely ignored. Finally, laboratory support for diagnosis and patient monitoring was limited in the rural facilities. The study highlights suboptimal quality of TB care in Rivers State with limitations in health education and HCT of patients for HIV as well as laboratory support for TB care in rural health facilities. We, therefore, recommend that adequate infection control measures, strict observance of the DOTS strategy and sufficient laboratory support be provided to TB clinics in the State.
Polygraph lie detection on real events in a laboratory setting.
Bradley, M T; Cullen, M C
1993-06-01
This laboratory study dealt with real-life intense emotional events. Subjects generated embarrassing stories from their experience, then submitted to polygraph testing and, by lying, denied their stories and, by telling the truth, denied a randomly assigned story. Money was given as an incentive to be judged innocent on each story. An interrogator, blind to the stories, used Control Question Tests and found subjects more deceptive when lying than when truthful. Stories interacted with order such that lying on the second story was more easily detected than lying on the first. Embarrassing stories provide an alternative to the use of mock crimes to study lie detection in the laboratory.
Sources of variation in baseline gene expression levels from toxicogenomics study control animals
The use of gene expression profiling in both clinical and laboratory settings would be enhanced by better characterization ofvariance due to individual, environmental, and technical factors. Meta-analysis ofmicroarray data from untreated or vehicle-treated animals within the con...
Song, Wenqi; Shen, Ying; Peng, Xiaoxia; Tian, Jian; Wang, Hui; Xu, Lili; Nie, Xiaolu; Ni, Xin
2015-05-26
The program of continuous quality improvement in clinical laboratory processes for complete blood count (CBC) was launched via the platform of Beijing Children's Hospital Group in order to improve the quality of pediatric clinical laboratories. Fifteen children's hospitals of Beijing Children's Hospital group were investigated using the method of Chinese adapted continuous quality improvement with PDCA (Plan-Do-Check-Action). The questionnaire survey and inter-laboratory comparison was conducted to find the existing problems, to analyze reasons, to set forth quality targets and to put them into practice. Then, targeted training was conducted to 15 children's hospitals and the second questionnaire survey, self examinations by the clinical laboratories was performed. At the same time, the Group's online internal quality control platform was established. Overall effects of the program were evaluated so that lay a foundation for the next stage of PDCA. Both quality of control system documents and CBC internal quality control scheme for all of clinical laboratories were improved through this program. In addition, standardization of performance verification was also improved, especially with the comparable verification rate of precision and internal laboratory results up to 100%. In terms of instrument calibration and mandatory diagnostic rates, only three out of the 15 hospitals (20%) failed to pass muster in 2014 from 46.67% (seven out of the 15 hospitals) in 2013. The abnormal data of intraday precision variance coefficients of the five CBC indicator parameters (WBC, RBC, Hb, Plt and Hct) of all the 15 laboratories accounted for 1.2% (2/165) in 2014, a marked decrease from 9.6% (14/145) in 2013. While the number of the hospitals using only one horizontal quality control object for daily quality control has dropped to three from five. The 15 hospitals organized a total of 263 times of training in 2014 from 101 times in 2013, up 160%. The quality improvement program for the clinical laboratories launched via the Hospital Group platform can promote the joint development of the pediatric clinical laboratory discipline of all the member hospitals with remarkable improvement results, and the experience is recommendable for further rollout.
The organization of perception and action in complex control skills
NASA Technical Reports Server (NTRS)
Miller, Richard A.; Jagacinski, Richard J.
1989-01-01
An attempt was made to describe the perceptual, cognitive, and action processes that account for highly skilled human performance in complex task environments. In order to study such a performance in a controlled setting, a laboratory task was constructed and three experiments were performed using human subjects. A general framework was developed for describing the organization of perceptual, cognitive, and action process.
Rosa, Rossana; Zavala, Bruno; Cain, Natalie; Anjan, Shweta; Aragon, Laura; Abbo, Lilian M
2018-03-01
Antimicrobial stewardship programs can optimize the management of Staphylococcus aureus bacteremia by integrating information technology and microbiology laboratory resources. This study describes our experience implementing an intervention consisting of real-time feedback and the use of an electronic order set for the management of S. aureus bacteremia. Infect Control Hosp Epidemiol 2018;39:346-349.
Kaufman, Kenton R.; Levine, James A.; Brey, Robert H.; McCrady, Shelly K.; Padgett, Denny J.; Joyner, Michael J.
2009-01-01
Objective To quantify the energy efficiency of locomotion and free-living physical activity energy expenditure of transfemoral amputees using a mechanical and microprocessor-controlled prosthetic knee. Design Repeated-measures design to evaluate comparative functional outcomes. Setting Exercise physiology laboratory and community free-living environment. Participants Subjects (N=15; 12 men, 3 women; age, 42±9y; range, 26 –57y) with transfemoral amputation. Intervention Research participants were long-term users of a mechanical prosthesis (20±10y as an amputee; range, 3–36y). They were fitted with a microprocessor-controlled knee prosthesis and allowed to acclimate (mean time, 18±8wk) before being retested. Main Outcome Measures Objective measurements of energy efficiency and total daily energy expenditure were obtained. The Prosthetic Evaluation Questionnaire was used to gather subjective feedback from the participants. Results Subjects demonstrated significantly increased physical activity–related energy expenditure levels in the participant’s free-living environment (P=.04) after wearing the microprocessor-controlled prosthetic knee joint. There was no significant difference in the energy efficiency of walking (P=.34). When using the microprocessor-controlled knee, the subjects expressed increased satisfaction in their daily lives (P=.02). Conclusions People ambulating with a microprocessor-controlled knee significantly increased their physical activity during daily life, outside the laboratory setting, and expressed an increased quality of life. PMID:18586142
Westbrook, J I; Georgiou, A; Dimos, A; Germanos, T
2006-01-01
Objective To assess the impact of a computerised pathology order entry system on laboratory turnaround times and test ordering within a teaching hospital. Methods A controlled before and after study compared test assays ordered from 11 wards two months before (n = 97 851) and after (n = 113 762) the implementation of a computerised pathology order entry system (Cerner Millennium Powerchart). Comparisons were made of laboratory turnaround times, frequency of tests ordered and specimens taken, proportions of patients having tests, average number per patient, and percentage of gentamicin and vancomycin specimens labelled as random. Results Intervention wards experienced an average decrease in turnaround of 15.5 minutes/test assay (range 73.8 to 58.3 minutes; p<0.001). Reductions were significant for prioritised and non‐prioritised tests, and for those done within and outside business hours. There was no significant change in the average number of tests (p = 0.228), or specimens per patient (p = 0.324), and no change in turnaround time for the control ward (p = 0.218). Use of structured order screens enhanced data provided to laboratories. Removing three test assays from the liver function order set resulted in significantly fewer of these tests being done. Conclusions Computerised order entry systems are an important element in achieving faster test results. These systems can influence test ordering patterns through structured order screens, manipulation of order sets, and analysis of real time data to assess the impact of such changes, not possible with paper based systems. The extent to which improvements translate into improved patient outcomes remains to be determined. A potentially limiting factor is clinicians' capacity to respond to, and make use of, faster test results. PMID:16461564
Lesuis, Nienke; den Broeder, Nathan; Boers, Nadine; Piek, Ester; Teerenstra, Steven; Hulscher, Marlies; van Vollenhoven, Ronald; den Broeder, Alfons A
2017-01-01
To examine the effects of an educational meeting and subsequent computer reminders on the number of ordered laboratory tests. Using interrupted time series analysis we assessed whether trends in the number of laboratory tests ordered by rheumatologists between September 2012 and September 2015 at the Sint Maartenskliniek (the Netherlands) changed following an educational meeting (September 2013) and the introduction of computer reminders into the Computerised Physician Order Entry System (July 2014). The analyses were done for the set of tests on which both interventions had focussed (intervention tests; complement, cryoglobulins, immunoglobins, myeloma protein) and a set of control tests unrelated to the interventions (alanine transferase, anti-cyclic citrullinated peptide, C-reactive protein, creatine, haemoglobin, leukocytes, mean corpuscular volume, rheumatoid factor and thrombocytes). At the start of the study, 101 intervention tests and 7660 control tests were ordered per month by the rheumatologists. After the educational meeting, both the level and trend of ordered intervention and control tests did not change significantly. After implementation of the reminders, the level of ordered intervention tests decreased by 85.0 tests (95%-CI -133.3 to -36.8, p<0.01), the level of control tests did not change following the introduction of reminders. In summary, an educational meeting alone was not effective in decreasing the number of ordered intervention tests, but the combination with computer reminders did result in a large decrease of those tests. Therefore, we recommend using computer reminders in addition to education if reduction of inappropriate test use is aimed for.
Chemistry in Microfluidic Channels
ERIC Educational Resources Information Center
Chia, Matthew C.; Sweeney, Christina M.; Odom, Teri W.
2011-01-01
General chemistry introduces principles such as acid-base chemistry, mixing, and precipitation that are usually demonstrated in bulk solutions. In this laboratory experiment, we describe how chemical reactions can be performed in a microfluidic channel to show advanced concepts such as laminar fluid flow and controlled precipitation. Three sets of…
Biological control of Botrytis gray mould on tomato cultivated in greenhouse.
Fiume, F; Fiume, G
2006-01-01
Research was carried out to evaluate the effectiveness of the biological control of the Botrytis gray mould, caused by Botrytis cinerea Pers., one of the most important fungal diseases of the tomato (Lycopersicon esculentum Mill.). Biological control was performed by using Trichoderma harzianum Rifai, an antagonist that is a naturally occurring fungus found on some plants and in the soil worldwide. Trichoderma spp. are fungi diffused in nearly all agricultural soils and in other environments such as decaying wood. The object of this research is to find control strategies to reduce chemical treatments that cause damage to the environment and increase the pathogen resistance, applying the biological control by using T. harzianum against B. cinerea. A commercial product containing a natural isolate of T. harzianum is trichodex (Makhteshim Chemical Works, LTD). The research was performed in laboratory and in greenhouse. In laboratory, radial growth reduction of B. cinerea, in presence of T. harzianum, was calculated in relation to the growth of the pathogen control, by using a specific formula that measures the percentage of the inhibition of the radial mycelial growth. In greenhouse, starting from the tomato fruit setting, the research was carried out comparing, by a randomized complete block experiment design, replicated four times, the following treatments:1) untreated control; 2) pyrimethanil (400 g/L of a.i.), at 200 cc/hL of c.i. (pyrimidine fungicides); 3) trichodex at 100g/hL (1 kg/ha); 4) trichodex at 200 g/hL (2 kg/ha); 5) trichodex at 400 g/hL (4 kg/ha). Before fruit setting, the plots were all treated against Botrytis gray mould with iprodione 50% (100 g/hL), procymidone 50% (100 g/hL) and switch (Novartis plant protection) at 80 g/hL. In dual culture, the inhibition of B. cinerea radial mycelial growth was 76%. No inhibition halo was observed between B. cinerea and T. harzianum colonies but, after 3 days, the pathogen colony radius resulted no more than 1.8 cm (towards T. harzianum). T. harzianum grew quickly and after 5 days the medium surface was completely colonized covering the B. cinerea colony. The laboratory tests were confirmed in greenhouse trials. Trichodex at 400 g/hL gave the best results, decreasing the disease over 50% compared to untreated control and over 70% compared to chemical control. After fruit setting, T. harzianum was the best in the control of Botrytis gray mould, allowing to avoid the use of the chemical fungicides that can be applied only up to the fruit setting, obtaining high quality tomato fruits.
Langley Wind Tunnel Data Quality Assurance-Check Standard Results
NASA Technical Reports Server (NTRS)
Hemsch, Michael J.; Grubb, John P.; Krieger, William B.; Cler, Daniel L.
2000-01-01
A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.
Interdisciplinary STEM education reform: dishing out art in a microbiology laboratory.
Adkins, Sarah J; Rock, Rachel K; Morris, J Jeffrey
2018-01-01
In the modern educational framework, life science and visual art are usually presented as mutually exclusive subjects. Despite this perceived disciplinary contrast, visual art has the ability to engage and provoke students in ways that can have important downstream effects on scientific discovery, especially when applied in a practical setting such as a laboratory course. This review broadly examines the benefit of interdisciplinary fusions of science and art as well as recent ways in which art strategies have been used in undergraduate biology classrooms. In a case study, we found that undergraduate students in an introductory microbiology laboratory course who participated in open-inquiry activities involving agar art had greater confidence in their personal efficacy as scientists compared to a control class. Collectively, these observations suggest that visual art can be a useful enhancement in the course-based undergraduate research setting, and science educators at all levels should consider incorporating artistic creativity in their own classroom strategies. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Evaluation of the MyWellness Key accelerometer.
Herrmann, S D; Hart, T L; Lee, C D; Ainsworth, B E
2011-02-01
to examine the concurrent validity of the Technogym MyWellness Key accelerometer against objective and subjective physical activity (PA) measures. randomised, cross-sectional design with two phases. The laboratory phase compared the MyWellness Key with the ActiGraph GT1M and the Yamax SW200 Digiwalker pedometer during graded treadmill walking, increasing speed each minute. The free-living phase compared the MyWellness Key with the ActiGraph, Digiwalker, Bouchard Activity cord (BAR) and Global Physical Activity Questionnaire (GPAQ) for seven continuous days. Data were analysed using Spearman rank-order correlation coefficients for all comparisons. laboratory and free-living phases. sixteen participants randomly stratified from 41 eligible respondents by sex (n=8 men; n=8 women) and PA levels (n=4 low, n=8 middle and n=4 high active). there was a strong association between the MyWellness Key and the ActiGraph accelerometer during controlled graded treadmill walking (r=0.91, p<0.01) and in free-living settings (r=0.73-0.76 for light to vigorous PA, respectively, p<0.01). No associations were observed between the MyWellness Key and the BAR and GPAQ (p>0.05). the MyWellness Key has a high concurrent validity with the ActiGraph accelerometer to detect PA in both controlled laboratory and free-living settings.
[Status of cardiorespiratory polysomnographic diagnosis in the sleep laboratory].
Penzel, T
1995-03-01
The different types of sleep related breathing and cardiovascular disorders are well known and defined nowadays. Thereby it is possible to present a configuration by which a cardiorespiratory sleep laboratory is enabled to perform a complete differential diagnosis. This configuration consists of the function sleep with EEG, EOG and EMG, the function respiration with respiratory effort, respiratory flow and oxygen saturation, and the cardiovascular function with ECG and blood pressure if indicated. Continuous monitoring by videocamera and a patient call system with a technician present during the entire recording time must be assured. Recording and evaluation of all signals can be done with chart polygraphs or with computer systems if they provide a high-resolution graphic monitor. Automatic sleep analysis systems support evaluation of polysomnograms. But automatic analysis of sleep stages as well as automatic analysis of respiratory disorders needs visual counterchecking before results can be accepted. On the basis of today's knowledge recommendation for the setting of a sleep laboratory were set and new sleep labs are controlled on a voluntary basis by a commission of the German society for sleep research and sleep medicine. This first step of quality control is introduced to establish a procedure to keep quality of diagnosis and treatment on a high level in this medical specialty.
Physiological responses to simulated firefighter exercise protocols in varying environments.
Horn, Gavin P; Kesler, Richard M; Motl, Robert W; Hsiao-Wecksler, Elizabeth T; Klaren, Rachel E; Ensari, Ipek; Petrucci, Matthew N; Fernhall, Bo; Rosengren, Karl S
2015-01-01
For decades, research to quantify the effects of firefighting activities and personal protective equipment on physiology and biomechanics has been conducted in a variety of testing environments. It is unknown if these different environments provide similar information and comparable responses. A novel Firefighting Activities Station, which simulates four common fireground tasks, is presented for use with an environmental chamber in a controlled laboratory setting. Nineteen firefighters completed three different exercise protocols following common research practices. Simulated firefighting activities conducted in an environmental chamber or live-fire structures elicited similar physiological responses (max heart rate: 190.1 vs 188.0 bpm, core temperature response: 0.047°C/min vs 0.043°C/min) and accelerometry counts. However, the response to a treadmill protocol commonly used in laboratory settings resulted in significantly lower heart rate (178.4 vs 188.0 bpm), core temperature response (0.037°C/min vs 0.043°C/min) and physical activity counts compared with firefighting activities in the burn building. Practitioner Summary: We introduce a new approach for simulating realistic firefighting activities in a controlled laboratory environment for ergonomics assessment of fire service equipment and personnel. Physiological responses to this proposed protocol more closely replicate those from live-fire activities than a traditional treadmill protocol and are simple to replicate and standardise.
Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities
Parsons, Linda M.; Somoskövi, Ákos; Gutierrez, Cristina; Lee, Evan; Paramasivan, C. N.; Abimiku, Alash'le; Spector, Steven; Roscigno, Giorgio; Nkengasong, John
2011-01-01
Summary: With an estimated 9.4 million new cases globally, tuberculosis (TB) continues to be a major public health concern. Eighty percent of all cases worldwide occur in 22 high-burden, mainly resource-poor settings. This devastating impact of tuberculosis on vulnerable populations is also driven by its deadly synergy with HIV. Therefore, building capacity and enhancing universal access to rapid and accurate laboratory diagnostics are necessary to control TB and HIV-TB coinfections in resource-limited countries. The present review describes several new and established methods as well as the issues and challenges associated with implementing quality tuberculosis laboratory services in such countries. Recently, the WHO has endorsed some of these novel methods, and they have been made available at discounted prices for procurement by the public health sector of high-burden countries. In addition, international and national laboratory partners and donors are currently evaluating other new diagnostics that will allow further and more rapid testing in point-of-care settings. While some techniques are simple, others have complex requirements, and therefore, it is important to carefully determine how to link these new tests and incorporate them within a country's national diagnostic algorithm. Finally, the successful implementation of these methods is dependent on key partnerships in the international laboratory community and ensuring that adequate quality assurance programs are inherent in each country's laboratory network. PMID:21482728
Propulsive Reaction Control System Model
NASA Technical Reports Server (NTRS)
Brugarolas, Paul; Phan, Linh H.; Serricchio, Frederick; San Martin, Alejandro M.
2011-01-01
This software models a propulsive reaction control system (RCS) for guidance, navigation, and control simulation purposes. The model includes the drive electronics, the electromechanical valve dynamics, the combustion dynamics, and thrust. This innovation follows the Mars Science Laboratory entry reaction control system design, and has been created to meet the Mars Science Laboratory (MSL) entry, descent, and landing simulation needs. It has been built to be plug-and-play on multiple MSL testbeds [analysis, Monte Carlo, flight software development, hardware-in-the-loop, and ATLO (assembly, test and launch operations) testbeds]. This RCS model is a C language program. It contains two main functions: the RCS electronics model function that models the RCS FPGA (field-programmable-gate-array) processing and commanding of the RCS valve, and the RCS dynamic model function that models the valve and combustion dynamics. In addition, this software provides support functions to initialize the model states, set parameters, access model telemetry, and access calculated thruster forces.
The relation of mothers' controlling vocalizations to children's intrinsic motivation.
Deci, E L; Driver, R E; Hotchkiss, L; Robbins, R J; Wilson, I M
1993-04-01
Twenty-six mother-child dyads played together in a laboratory setting. Play sessions were surreptitiously videotaped (with mothers' permission), and each maternal vocalization was transcribed and coded, first into 1 of 24 categories and then ipso facto into one of three supercategories--namely, controlling, autonomy supportive, and neutral. The degree of mothers' controllingness was calculated as the percentage of vocalizations coded as controlling. This index was correlated with the intrinsic motivation of their 6- or 7-year-old children, as assessed primarily by the free-choice behavioral measure and secondarily by a child self-report measure of interest and liking for the task. Both correlations were significantly negative, thereby suggesting that the robust laboratory findings of a negative relation between controlling contexts and individuals' intrinsic motivation are directly generalizable to the domain of parenting. Results are discussed in terms of the processes that undermine intrinsic motivation and the means through which parental controllingness is communicated.
Laboratory Data for X-Ray Astronomy
NASA Technical Reports Server (NTRS)
Beiersdorfer, P.; Brown, G. V.; Chen, H.; Gu, M.-F.; Kahn, S. M.; Lepson, J. K.; Savin, D. W.; Utter, S. B.
2000-01-01
Laboratory facilities have made great strides in producing large sets of reliable data for X-ray astronomy, which include ionization and recombination cross sections needed for charge balance calculations as well as the atomic data needed for interpreting X-ray line formation. We discuss data from the new generation sources and pay special attention to the LLNL electron beam ion trap experiment, which is unique in its ability to provide direct laboratory access to spectral data under precisely controlled conditions that simulate those found in many astrophysical plasmas. Examples of spectral data obtained in the 1-160 A wavelength range are given illustrating the type of laboratory X-ray data produced in support of such missions as Chandra, X-Ray Multi-Mirror telescope (XMM), Advanced Satellite for Cosmology and Astrophysics (ASCA) and Extreme Ultraviolet Explorer Satellite (EUVE).
Performance Based Design of a New Virtual Locomotion Control
2000-11-01
constraints on movements, caloric energy expenditure , etc.). (2) The control action should interact with other actions (looking, manipulation, posturing...velocity, natural cadence, caloric expenditure , etc.) but it is unlikely that one set of tuning parameters will satisfy all criteria. Experimental...tethered for safety. OSIRIS, developed by the US Army’s Night Vision Laboratory, is a stair -stepper device that can only be used upright [Lorenzo et al
DOT National Transportation Integrated Search
2012-04-01
The goal of this study was to evaluate the performance of Fiber Bragg Grating (FBG) sensors able to detect impacts with : different frequencies on a bridge pier. The FBG technology was evaluated under controlled conditions in a laboratory : flume set...
Minicomputers in the Teaching Laboratory - An Example from Physics.
ERIC Educational Resources Information Center
Farr, John E.; van den Berg, Willem H.
Microcomputers are commonly interfaced to external devices in scientific, industrial, and consumer settings for data acquisition and for control. The general problem under consideration is the task of taking measurements of some continuous phenomenon, transforming them into digital form, and storing the data in the microcomputer for later use.…
Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro
2016-01-01
Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.
Quality in the molecular microbiology laboratory.
Wallace, Paul S; MacKay, William G
2013-01-01
In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.
Robotic laboratory for distance education
NASA Astrophysics Data System (ADS)
Luciano, Sarah C.; Kost, Alan R.
2016-09-01
This project involves the construction of a remote-controlled laboratory experiment that can be accessed by online students. The project addresses a need to provide a laboratory experience for students who are taking online courses to be able to provide an in-class experience. The chosen task for the remote user is an optical engineering experiment, specifically aligning a spatial filter. We instrument the physical laboratory set up in Tucson, AZ at the University of Arizona. The hardware in the spatial filter experiment is augmented by motors and cameras to allow the user to remotely control the hardware. The user interacts with a software on their computer, which communicates with a server via Internet connection to the host computer in the Optics Laboratory at the University of Arizona. Our final overall system is comprised of several subsystems. These are the optical experiment set-up, which is a spatial filter experiment; the mechanical subsystem, which interfaces the motors with the micrometers to move the optical hardware; the electrical subsystem, which allows for the electrical communications from the remote computer to the host computer to the hardware; and finally the software subsystem, which is the means by which messages are communicated throughout the system. The goal of the project is to convey as much of an in-lab experience as possible by allowing the user to directly manipulate hardware and receive visual feedback in real-time. Thus, the remote user is able to learn important concepts from this particular experiment and is able to connect theory to the physical world by actually seeing the outcome of a procedure. The latter is a learning experience that is often lost with distance learning and is one that this project hopes to provide.
Control of free-flying space robot manipulator systems
NASA Technical Reports Server (NTRS)
Cannon, Robert H., Jr.
1988-01-01
The focus of the work is to develop and perform a set of research projects using laboratory models of satellite robots. These devices use air cushion technology to simulate in two dimensions the drag-free, zero-g conditions of space. Five research areas are examined: cooperative manipulation on a fixed base; cooperative manipulation on a free-floating base; global navigation and control of a free-floating robot; an alternative transport mode call Locomotion Enhancement via Arm Push-Off (LEAP), and adaptive control of LEAP.
NASA Astrophysics Data System (ADS)
Wilson, Meredith
Geologic field trips are among the most beneficial learning experiences for students as they engage the topic of geology, but they are also difficult environments to maximize learning. This action research study explored one facet of the problems associated with teaching geology in the field by attempting to improve the transition of undergraduate students from a traditional laboratory setting to an authentic field environment. Utilizing an artificial outcrop, called the GeoScene, during an introductory college-level non-majors geology course, the transition was studied. The GeoScene was utilized in this study as an intermediary between laboratory and authentic field based experiences, allowing students to apply traditional laboratory learning in an outdoor environment. The GeoScene represented a faux field environment; outside, more complex and tangible than a laboratory, but also simplified geologically and located safely within the confines of an educational setting. This exploratory study employed a mixed-methods action research design. The action research design allowed for systematic inquiry by the teacher/researcher into how the students learned. The mixed-methods approach garnered several types of qualitative and quantitative data to explore phenomena and support conclusions. Several types of data were collected and analyzed, including: visual recordings of the intervention, interviews, analytic memos, student reflections, field practical exams, and a pre/post knowledge and skills survey, to determine whether the intervention affected student comprehension and interpretation of geologic phenomena in an authentic field environment, and if so, how. Students enrolled in two different sections of the same laboratory course, sharing a common lecture, participated in laboratory exercises implementing experiential learning and constructivist pedagogies that focused on learning the basic geological skills necessary for work in a field environment. These laboratory activities were followed by an approximate 15 minute intervention at the GeoScene for a treatment group of students (n=13) to attempt to mitigate potential barriers, such as: self-efficacy, novelty space, and spatial skills, which hinder student performance in an authentic field environment. Comparisons were made to a control group (n=12), who did not participate in GeoScene activities, but completed additional exercises and applications in the laboratory setting. Qualitative data sources suggested that the GeoScene treatment was a positive addition to the laboratory studies and improved the student transition to the field environment by: (1) reducing anxiety and decreasing heightened stimulus associated with the novelty of the authentic field environment, (2) allowing a physical transition between the laboratory and field that shifted concepts learned in the lab to the field environment, and (3) improving critical analysis of geologic phenomena. This was corroborated by the quantitative data that suggested the treatment group may have outperformed the control group in geology content related skills taught in the laboratory, and supported by the GeoScene, while in an authentic field environment (p≤0.01, delta=0.507).
Biosafety and biosecurity measures: management of biosafety level 3 facilities.
Zaki, Adel N
2010-11-01
With the increasing biological threat from emerging infectious diseases and bioterrorism, it has become essential for governments around the globe to increase awareness and preparedness for identifying and containing those agents. This article introduces the basic concepts of laboratory management, laboratory biosafety and laboratory biosecurity. Assessment criteria for laboratories' biorisk should include both biosafety and biosecurity measures. The assessment requires setting specific goals and selecting management approaches. In order to implement technologies at the laboratory working level, a management team should be created whose role is to implement biorisk policies, rules and regulations appropriate for that facility. Rules and regulations required by government authorities are presented, with special emphasis on methods for air control, and liquid and solid waste management. Management and biorisk measures and appropriate physical facilities must keep pace, ensuring efficient facilities that protect workers, the environment, the product (research, diagnostic and/or vaccine) and the biological pathogen. Published by Elsevier B.V.
Time measurements with a mobile device using sound
NASA Astrophysics Data System (ADS)
Wisman, Raymond F.; Spahn, Gabriel; Forinash, Kyle
2018-05-01
Data collection is a fundamental skill in science education, one that students generally practice in a controlled setting using equipment only available in the classroom laboratory. However, using smartphones with their built-in sensors and often free apps, many fundamental experiments can be performed outside the laboratory. Taking advantage of these tools often require creative approaches to data collection and exploring alternative strategies for experimental procedures. As examples, we present several experiments using smartphones and apps that record and analyze sound to measure a variety of physical properties.
Quality and rural-urban comparison of tuberculosis care in Rivers State, Nigeria
Tobin-West, Charles Ibiene; Isodje, Anastasia
2016-01-01
Introduction Nigeria ranks among countries with the highest burden of tuberculosis. Yet evidence continues to indicate poor treatment outcomes which have been attributed to poor quality of care. This study aims to identify some of the systemic problems in order to inform policy decisions for improved quality of services and treatment outcomes in Nigeria. Methods A comparative assessment of the quality of TB care in rural and urban health facilities was carried out between May and June 2013, employing the Donabedian model of quality assessment. Data was analysed using the SPSS software package version 20.0. The level of significance was set at p < 0.05. Results Health facility infrastructures were more constrained in the urban than rural settings. Both the urban and rural facilities lacked adequate facilities for infection control such as, running water, air filter respirators, hand gloves and extractor fans. Health education and HIV counselling and testing (HCT) were limited in rural facilities compared to urban facilities. Although anti-TB drugs were generally available in both settings, the DOTS strategy in patient care was completely ignored. Finally, laboratory support for diagnosis and patient monitoring was limited in the rural facilities. Conclusion The study highlights suboptimal quality of TB care in Rivers State with limitations in health education and HCT of patients for HIV as well as laboratory support for TB care in rural health facilities. We, therefore, recommend that adequate infection control measures, strict observance of the DOTS strategy and sufficient laboratory support be provided to TB clinics in the State. PMID:27642401
MDMA effects consistent across laboratories
Kirkpatrick, Matthew G.; Baggott, Matthew J.; Mendelson, John E.; Galloway, Gantt P.; Liechti, Matthias E.; Hysek, Cédric M.; de Wit, Harriet
2014-01-01
Rationale Several laboratories have conducted placebo-controlled drug challenge studies with MDMA, providing a unique source of data to examine the reliability of the acute effects of the drug across subject samples and settings. We examined the subjective and physiological responses to the drug across three different laboratories, and investigated the influence of prior MDMA use. Methods Overall, 220 healthy volunteers with varying levels of previous MDMA experience participated in laboratory-based studies in which they received placebo or oral MDMA (1.5 mg/kg or 125 mg fixed dose) under double blind conditions. Cardiovascular and subjective effects were assessed before and repeatedly after drug administration. The studies were conducted independently by investigators in Basel, San Francisco and Chicago. Results Despite methodological differences between the studies and differences in the subjects' drug use histories, MDMA produced very similar cardiovascular and subjective effects across the sites. The participants' prior use of MDMA was inversely related to feeling `Any Drug Effect' only at sites testing more experienced users. Conclusions These data indicate that the pharmacological effects of MDMA are robust and highly reproducible across settings. There was also modest evidence for tolerance to the effects of MDMA in regular users. PMID:24633447
Capraro, Valerio; Cococcioni, Giorgia
2015-07-22
Recent studies suggest that cooperative decision-making in one-shot interactions is a history-dependent dynamic process: promoting intuition versus deliberation typically has a positive effect on cooperation (dynamism) among people living in a cooperative setting and with no previous experience in economic games on cooperation (history dependence). Here, we report on a laboratory experiment exploring how these findings transfer to a non-cooperative setting. We find two major results: (i) promoting intuition versus deliberation has no effect on cooperative behaviour among inexperienced subjects living in a non-cooperative setting; (ii) experienced subjects cooperate more than inexperienced subjects, but only under time pressure. These results suggest that cooperation is a learning process, rather than an instinctive impulse or a self-controlled choice, and that experience operates primarily via the channel of intuition. Our findings shed further light on the cognitive basis of human cooperative decision-making and provide further support for the recently proposed social heuristics hypothesis. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
A framework for capturing clinical data sets from computerized sources.
McDonald, C J; Overhage, J M; Dexter, P; Takesue, B Y; Dwyer, D M
1997-10-15
The pressure to improve health care and provide better care at a lower cost has generated the need for efficient capture of clinical data. Many data sets are now being defined to analyze health care. Historically, review and research organizations have simply determined what data they wanted to collect, developed forms, and then gathered the information through chart review without regard to what is already available institutionally in computerized databases. Today, much electronic patient information is available in operational data systems (for example, laboratory systems, pharmacy systems, and surgical scheduling systems) and is accessible by agencies and organizations through standards for messages, codes, and encrypted electronic mail. Such agencies and organizations should define the elements of their data sets in terms of standardized operational data, and data producers should fully adopt these code and message standards. The Health Plan Employer Data and Information Set and the Council of State and Territorial Epidemiologists in collaboration with the Centers for Disease Control and Prevention and the Association of State and Territorial Public Health Laboratory Directors provide examples of how this can be done.
A Lean Six Sigma approach to the improvement of the selenium analysis method.
Cloete, Bronwyn C; Bester, André
2012-11-02
Reliable results represent the pinnacle assessment of quality of an analytical laboratory, and therefore variability is considered to be a critical quality problem associated with the selenium analysis method executed at Western Cape Provincial Veterinary Laboratory (WCPVL). The elimination and control of variability is undoubtedly of significant importance because of the narrow margin of safety between toxic and deficient doses of the trace element for good animal health. A quality methodology known as Lean Six Sigma was believed to present the most feasible solution for overcoming the adverse effect of variation, through steps towards analytical process improvement. Lean Six Sigma represents a form of scientific method type, which is empirical, inductive and deductive, and systematic, which relies on data, and is fact-based. The Lean Six Sigma methodology comprises five macro-phases, namely Define, Measure, Analyse, Improve and Control (DMAIC). Both qualitative and quantitative laboratory data were collected in terms of these phases. Qualitative data were collected by using quality-tools, namely an Ishikawa diagram, a Pareto chart, Kaizen analysis and a Failure Mode Effect analysis tool. Quantitative laboratory data, based on the analytical chemistry test method, were collected through a controlled experiment. The controlled experiment entailed 13 replicated runs of the selenium test method, whereby 11 samples were repetitively analysed, whilst Certified Reference Material (CRM) was also included in 6 of the runs. Laboratory results obtained from the controlled experiment was analysed by using statistical methods, commonly associated with quality validation of chemistry procedures. Analysis of both sets of data yielded an improved selenium analysis method, believed to provide greater reliability of results, in addition to a greatly reduced cycle time and superior control features. Lean Six Sigma may therefore be regarded as a valuable tool in any laboratory, and represents both a management discipline, and a standardised approach to problem solving and process optimisation.
Hassan, Hishar; Abu Bakar, Suharzelim; Halim, Khairul Najah Che A; Idris, Jaleezah; Nordin, Abdul Jalil
2016-01-01
Prostate cancer continues to be the most prevalent cancer in men in Malaysia. As time progresses, the prospect of PET imaging modality in diagnosis of prostate cancer is promising, with on-going improvement on novel tracers. Among all tracers, 18F-Fluorocholine is reported to be a reputable tracer and reliable diagnostic technique for prostate imaging. Nonetheless, only 18F-Fluorodeoxyglucose (18F-FDG) is available and used in most oncology cases in Malaysia. With a small scale GMP-based radiopharmaceuticals laboratory set-up, initial efforts have been taken to put Malaysia on 18F-Fluorocholine map. This article presents a convenient, efficient and reliable method for quality control analysis of 18F-Fluorocholine. Besides, the aim of this research work is to assist local GMP radiopharmaceuticals laboratories and local authority in Malaysia for quality control analysis of 18F-Fluorocholine guideline. In this study, prior to synthesis, quality control analysis method for 18F-Fluorocholine was developed and validated, by adapting the equipment set-up used in 18F-Fluorodeoxyglucose (18FFDG) routine production. Quality control on the 18F-Fluorocholine was performed by means of pH, radionuclidic identity, radio-high performance liquid chromatography equipped with ultraviolet, radio- thin layer chromatography, gas chromatography and filter integrity test. Post-synthesis; the pH of 18F-Fluorocholine was 6.42 ± 0.04, with half-life of 109.5 minutes (n = 12). The radiochemical purity was consistently higher than 99%, both in radio-high performance liquid chromatography equipped with ultraviolet (r-HPLC; SCX column, 0.25 M NaH2PO4: acetonitrile) and radio-thin layer chromatography method (r-TLC). The calculated relative retention time (RRT) in r-HPLC was 1.02, whereas the retention factor (Rf) in r-TLC was 0.64. Potential impurities from 18F-Fluorocholine synthesis such as ethanol, acetonitrile, dimethylethanolamine and dibromomethane were determined in gas chromatography. Using our parameters, (capillary column: DB-200, 30 m x 0.53 mm x 1 um) and oven temperature of 35°C (isothermal), all compounds were well resolved and eluted within 3 minutes. Level of ethanol and acetonitrile in 18F-Fluorocholine were detected below threshold limit; less than 5 mg/ml and 0.41 mg/ml respectively. Meanwhile, dimethylethanolamine and dibromomethane were undetectable. A convenient, efficient and reliable quality control analysis work-up procedure for 18FFluorocholine has been established and validated to comply all the release criteria. The convenient method of quality control analysis may provide a guideline to local GMP radiopharmaceutical laboratories to start producing 18F-Fluorocholine as a tracer for prostate cancer imaging.
Network Randomization and Dynamic Defense for Critical Infrastructure Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chavez, Adrian R.; Martin, Mitchell Tyler; Hamlet, Jason
2015-04-01
Critical Infrastructure control systems continue to foster predictable communication paths, static configurations, and unpatched systems that allow easy access to our nation's most critical assets. This makes them attractive targets for cyber intrusion. We seek to address these attack vectors by automatically randomizing network settings, randomizing applications on the end devices themselves, and dynamically defending these systems against active attacks. Applying these protective measures will convert control systems into moving targets that proactively defend themselves against attack. Sandia National Laboratories has led this effort by gathering operational and technical requirements from Tennessee Valley Authority (TVA) and performing research and developmentmore » to create a proof-of-concept solution. Our proof-of-concept has been tested in a laboratory environment with over 300 nodes. The vision of this project is to enhance control system security by converting existing control systems into moving targets and building these security measures into future systems while meeting the unique constraints that control systems face.« less
A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.
Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven
2015-05-01
Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).
The Development of the AFIT Communications Laboratory and Experiments for Communications Students.
1985-12-01
Actiatesdigtal wag*andPermits monitoring of max. Actiatesdigial sorag animum signal excursions over selects the "A" or " porn indeienite time...level at which the vertical display is installed in the 71.5. either peak detected or digitally averaged. Video signals above the level set by the... Video signals below the level set by the PEAK AVERAGE control or VERT P05 Positions the display Or baseline on digitally averaged and stored. th c_
Sciacovelli, Laura; O'Kane, Maurice; Skaik, Younis Abdelwahab; Caciagli, Patrizio; Pellegrini, Cristina; Da Rin, Giorgio; Ivanov, Agnes; Ghys, Timothy; Plebani, Mario
2011-05-01
The adoption of Quality Indicators (QIs) has prompted the development of tools to measure and evaluate the quality and effectiveness of laboratory testing, first in the hospital setting and subsequently in ambulatory and other care settings. While Laboratory Medicine has an important role in the delivery of high-quality care, no consensus exists as yet on the use of QIs focussing on all steps of the laboratory total testing process (TTP), and further research in this area is required. In order to reduce errors in laboratory testing, the IFCC Working Group on "Laboratory Errors and Patient Safety" (WG-LEPS) developed a series of Quality Indicators, specifically designed for clinical laboratories. In the first phase of the project, specific QIs for key processes of the TTP were identified, including all the pre-, intra- and post-analytic steps. The overall aim of the project is to create a common reporting system for clinical laboratories based on standardized data collection, and to define state-of-the-art and Quality Specifications (QSs) for each QI independent of: a) the size of organization and type of activities; b) the complexity of processes undertaken; and c) different degree of knowledge and ability of the staff. The aim of the present paper is to report the results collected from participating laboratories from February 2008 to December 2009 and to identify preliminary QSs. The results demonstrate that a Model of Quality Indicators managed as an External Quality Assurance Program can serve as a tool to monitor and control the pre-, intra- and post-analytical activities. It might also allow clinical laboratories to identify risks that lead to errors resulting in patient harm: identification and design of practices that eliminate medical errors; the sharing of information and education of clinical and laboratory teams on practices that reduce or prevent errors; the monitoring and evaluation of improvement activities.
Childress, Ann C; Kollins, Scott H; Cutler, Andrew J; Marraffino, Andrea; Sikes, Carolyn R
2017-02-01
Methylphenidate extended-release orally disintegrating tablets (MPH XR-ODTs) represent a new technology for MPH delivery. ODTs disintegrate in the mouth without water and provide a pharmacokinetic profile that is consistent with once-daily dosing. This study sought to determine the efficacy, safety, and tolerability of this novel MPH XR-ODT formulation in school-age children with attention-deficit/hyperactivity disorder (ADHD) in a laboratory classroom setting. Children aged 6-12 years with ADHD (n = 87) were enrolled in this randomized, multicenter, double-blind, placebo-controlled, parallel, laboratory classroom study. The MPH XR-ODT dose was titrated to an optimized dose during a 4-week open-label period and maintained on that dose for 1 week. Participants (n = 85) were then randomized to receive their optimized dose of MPH XR-ODT or placebo once daily for 1 week (double blind), culminating in a laboratory classroom testing day. Efficacy was evaluated using the Swanson, Kotkin, Agler, M-Flynn, and Pelham (SKAMP) Attention, Deportment, and Combined scores along with Permanent Product Measure of Performance (PERMP; Attempted and Correct) assessments. Onset and duration of drug action were also evaluated as key secondary endpoints. Safety assessments included adverse events (AEs), physical examinations, electrocardiograms (ECGs), and the Columbia Suicide Severity Rating Scale (C-SSRS). The average SKAMP-Combined score on the classroom study day was significantly better for the MPH XR-ODT group (n = 43) than for the placebo group (n = 39; p < 0.0001). The effect was evident at 1 hour and lasted through 12 hours postdose. The average SKAMP-Attention, SKAMP-Deportment, PERMP-A, and PERMP-C scores were indicative of significantly greater ADHD symptom control for the MPH XR-ODT group. The most common AEs reported were decreased appetite, upper abdominal pain, headache, insomnia, upper respiratory tract infection, affect lability, irritability, cough, and vomiting. MPH XR-ODT was effective and well tolerated for the treatment of children with ADHD in a laboratory classroom setting. Clinical Trial Registry: NCT01835548 ( ClinicalTrials.gov ).
Cirillo, Daniela M.; Hoffner, Sven; Ismail, Nazir A.; Kaur, Devinder; Lounis, Nacer; Metchock, Beverly; Pfyffer, Gaby E.; Venter, Amour
2016-01-01
The aim of this study was to establish standardized drug susceptibility testing (DST) methodologies and reference MIC quality control (QC) ranges for bedaquiline, a diarylquinoline antimycobacterial, used in the treatment of adults with multidrug-resistant tuberculosis. Two tier-2 QC reproducibility studies of bedaquiline DST were conducted in eight laboratories using Clinical Laboratory and Standards Institute (CLSI) guidelines. Agar dilution and broth microdilution methods were evaluated. Mycobacterium tuberculosis H37Rv was used as the QC reference strain. Bedaquiline MIC frequency, mode, and geometric mean were calculated. When resulting data occurred outside predefined CLSI criteria, the entire laboratory data set was excluded. For the agar dilution MIC, a 4-dilution QC range (0.015 to 0.12 μg/ml) centered around the geometric mean included 95.8% (7H10 agar dilution; 204/213 observations with one data set excluded) or 95.9% (7H11 agar dilution; 232/242) of bedaquiline MICs. For the 7H9 broth microdilution MIC, a 3-dilution QC range (0.015 to 0.06 μg/ml) centered around the mode included 98.1% (207/211, with one data set excluded) of bedaquiline MICs. Microbiological equivalence was demonstrated for bedaquiline MICs determined using 7H10 agar and 7H11 agar but not for bedaquiline MICs determined using 7H9 broth and 7H10 agar or 7H9 broth and 7H11 agar. Bedaquiline DST methodologies and MIC QC ranges against the H37Rv M. tuberculosis reference strain have been established: 0.015 to 0.12 μg/ml for the 7H10 and 7H11 agar dilution MICs and 0.015 to 0.06 μg/ml for the 7H9 broth microdilution MIC. These methodologies and QC ranges will be submitted to CLSI and EUCAST to inform future research and provide guidance for routine clinical bedaquiline DST in laboratories worldwide. PMID:27654337
NREL and Alstom Celebrate Wind Turbine Installation | News | NREL
. Department of Energy (DOE) and DOE's National Renewable Energy Laboratory (NREL), along with officials from technology areas including controls and offshore wind energy. About Alstom Alstom is a global leader in the world of power generation, power transmission and rail infrastructure, and sets the benchmark for
Experimenting from a Distance in the Case of Rutherford Scattering
ERIC Educational Resources Information Center
Grober, S.; Vetter, M.; Eckert, B.; Jodl, H. -J.
2010-01-01
The Rutherford scattering experiment plays a central role in working out atomic models in physics and chemistry. Nevertheless, the experiment is rarely performed at school or in introductory physics courses at university. Therefore, we realized this experiment as a remotely controlled laboratory (RCL), i.e. the experiment is set up in reality and…
Auditory Learning Using a Portable Real-Time Vocoder: Preliminary Findings
ERIC Educational Resources Information Center
Casserly, Elizabeth D.; Pisoni, David B.
2015-01-01
Purpose: Although traditional study of auditory training has been in controlled laboratory settings, interest has been increasing in more interactive options. The authors examine whether such interactive training can result in short-term perceptual learning, and the range of perceptual skills it impacts. Method: Experiments 1 (N = 37) and 2 (N =…
Baucom, Brian R W; Baucom, Katherine J W; Hogan, Jasara N; Crenshaw, Alexander O; Bourne, Stacia V; Crowell, Sheila E; Georgiou, Panayiotis; Goodwin, Matthew S
2018-03-25
Cardiovascular reactivity during spousal conflict is considered to be one of the main pathways for relationship distress to impact physical, mental, and relationship health. However, the magnitude of association between cardiovascular reactivity during laboratory marital conflict and relationship functioning is small and inconsistent given the scope of its importance in theoretical models of intimate relationships. This study tests the possibility that cardiovascular data collected in laboratory settings downwardly bias the magnitude of these associations when compared to measures obtained in naturalistic settings. Ambulatory cardiovascular reactivity data were collected from 20 couples during two relationship conflicts in a research laboratory, two planned relationship conflicts at couples' homes, and two spontaneous relationship conflicts during couples' daily lives. Associations between self-report measures of relationship functioning, individual functioning, and cardiovascular reactivity across settings are tested using multilevel models. Cardiovascular reactivity was significantly larger during planned and spontaneous relationship conflicts in naturalistic settings than during planned relationship conflicts in the laboratory. Similarly, associations with relationship and individual functioning variables were statistically significantly larger for cardiovascular data collected in naturalistic settings than the same data collected in the laboratory. Our findings suggest that cardiovascular reactivity during spousal conflict in naturalistic settings is statistically significantly different from that elicited in laboratory settings both in magnitude and in the pattern of associations with a wide range of inter- and intrapersonal variables. These differences in findings across laboratory and naturalistic physiological responses highlight the value of testing physiological phenomena across interaction contexts in romantic relationships. © 2018 Family Process Institute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballhausen, Hendrik, E-mail: hendrik.ballhausen@med.uni-muenchen.de; Hieber, Sheila; Li, Minglun
2014-08-15
Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematicmore » and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.« less
BOREAS TE-9 NSA Photosynthetic Response Data
NASA Technical Reports Server (NTRS)
Hall, Forrest G.; Curd, Shelaine (Editor); Dang, Qinglai; Margolis, Hank; Coyea, Marie
2000-01-01
The Boreal Ecosystem-Atmospheric Study (BOREAS) TE-9 (Terrestrial Ecology) team collected several data sets related to chemical and photosynthetic properties of leaves. This data set describes: (1) the response of leaf and shoot-level photosynthesis to ambient and intercellular CO2 concentration, temperature, and incident photosynthetically active radiation (PAR) for black spruce, jack pine, and aspen during the three intensive field campaigns (IFCs) in 1994 in the Northern Study Area (NSA); (2) the response of stomatal conductance to vapor pressure difference throughout the growing season of 1994; and (3) a range of shoot water potentials (controlled in the laboratory) for black spruce and jack pine. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
A Manual Control Test for the Detection and Deterrence of Impaired Drivers
NASA Technical Reports Server (NTRS)
Stein, A. C.; Allen, R. W.; Jex, H. R.
1984-01-01
A brief manual control test and a decision strategy were developed, laboratory tested, and field validated which provide a means for detecting human operator impairment from alcohol or other drugs. The test requires the operator to stabilize progressively unstable controlled element dynamics. Control theory and experimental data verify that the human operator's control ability on this task is constrained by basic cybernetic characteristics, and that task performance is reliably affected by impairment effects on these characteristics. Assessment of human operator control ability is determined by a statistically based decision strategy. The operator is allowed several chances to exceed a preset pass criterion. Procedures are described for setting the pass criterion based on individual ability and a desired unimpaired failure rate. These procedures were field tested with apparatus installed in automobiles that were designed to discourage drunk drivers from operating their vehicles. This test program demonstrated that the control task and detection strategy could be applied in a practical setting to screen human operators for impairment in their basic cybernetic skills.
To QC or not to QC: the key to a consistent laboratory?
Lane, Michelle; Mitchell, Megan; Cashman, Kara S; Feil, Deanne; Wakefield, Sarah; Zander-Fox, Deirdre L
2008-01-01
A limiting factor in every embryology laboratory is its capacity to grow 'normal' embryos. In human in vitro fertilisation (IVF), there is considerable awareness that the environment of the laboratory itself can alter the quality of the embryos produced and the industry as a whole has moved towards the implementation of auditable quality management systems. Furthermore, in some countries, such as Australia, an established quality management system is mandatory for clinical IVF practice, but such systems are less frequently found in other embryology laboratories. Although the same challenges of supporting consistent and repeatable embryo development are paramount to success in all embryology laboratories, it could be argued that they are more important in a research setting where often the measured outcomes are at an intracellular or molecular level. In the present review, we have outlined the role and importance of quality control and quality assurance systems in any embryo laboratory and have highlighted examples of how simple monitoring can provide consistency and avoid the induction of artefacts, irrespective of the laboratory's purpose, function or species involved.
An intelligent CNC machine control system architecture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D.J.; Loucks, C.S.
1996-10-01
Intelligent, agile manufacturing relies on automated programming of digitally controlled processes. Currently, processes such as Computer Numerically Controlled (CNC) machining are difficult to automate because of highly restrictive controllers and poor software environments. It is also difficult to utilize sensors and process models for adaptive control, or to integrate machining processes with other tasks within a factory floor setting. As part of a Laboratory Directed Research and Development (LDRD) program, a CNC machine control system architecture based on object-oriented design and graphical programming has been developed to address some of these problems and to demonstrate automated agile machining applications usingmore » platform-independent software.« less
Shum, Bennett O V; Henner, Ilya; Belluoccio, Daniele; Hinchcliffe, Marcus J
2017-07-01
The sensitivity and specificity of next-generation sequencing laboratory developed tests (LDTs) are typically determined by an analyte-specific approach. Analyte-specific validations use disease-specific controls to assess an LDT's ability to detect known pathogenic variants. Alternatively, a methods-based approach can be used for LDT technical validations. Methods-focused validations do not use disease-specific controls but use benchmark reference DNA that contains known variants (benign, variants of unknown significance, and pathogenic) to assess variant calling accuracy of a next-generation sequencing workflow. Recently, four whole-genome reference materials (RMs) from the National Institute of Standards and Technology (NIST) were released to standardize methods-based validations of next-generation sequencing panels across laboratories. We provide a practical method for using NIST RMs to validate multigene panels. We analyzed the utility of RMs in validating a novel newborn screening test that targets 70 genes, called NEO1. Despite the NIST RM variant truth set originating from multiple sequencing platforms, replicates, and library types, we discovered a 5.2% false-negative variant detection rate in the RM truth set genes that were assessed in our validation. We developed a strategy using complementary non-RM controls to demonstrate 99.6% sensitivity of the NEO1 test in detecting variants. Our findings have implications for laboratories or proficiency testing organizations using whole-genome NIST RMs for testing. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Entry Guidance for the 2011 Mars Science Laboratory Mission
NASA Technical Reports Server (NTRS)
Mendeck, Gavin F.; Craig, Lynn E.
2011-01-01
The 2011 Mars Science Laboratory will be the first Mars mission to attempt a guided entry to safely deliver the rover to a touchdown ellipse of 25 km x 20 km. The Entry Terminal Point Controller guidance algorithm is derived from the final phase Apollo Command Module guidance and, like Apollo, modulates the bank angle to control the range flown. For application to Mars landers which must make use of the tenuous Martian atmosphere, it is critical to balance the lift of the vehicle to minimize the range error while still ensuring a safe deploy altitude. An overview of the process to generate optimized guidance settings is presented, discussing improvements made over the last nine years. Key dispersions driving deploy ellipse and altitude performance are identified. Performance sensitivities including attitude initialization error and the velocity of transition from range control to heading alignment are presented.
Physiological Responses to Racism and Discrimination: An Assessment of the Evidence
Harrell, Jules P.; Hall, Sadiki; Taliaferro, James
2003-01-01
A growing body of research explores the impact of encounters with racism or discrimination on physiological activity. Investigators have collected these data in laboratories and in controlled clinical settings. Several but not all of the studies suggest that higher blood pressure levels are associated with the tendency not to recall or report occurrences identified as racist and discriminatory. Investigators have reported that physiological arousal is associated with laboratory analogues of ethnic discrimination and mistreatment. Evidence from survey and laboratory studies suggests that personality variables and cultural orientation moderate the impact of racial discrimination. The neural pathways that mediate these physiological reactions are not known. The evidence supports the notion that direct encounters with discriminatory events contribute to negative health outcomes. PMID:12554577
DHM and serious games: a case-study oil and gas laboratories.
Santos, V; Zamberlan, M; Streit, P; Oliveira, J; Guimarães, C; Pastura, F; Cid, G
2012-01-01
The aim in this paper is to present a research on the application of serious games for the design of laboratories in the oil and gas industries. The focus is in human virtual representation acquired from 3D scanning, human interaction, workspace layout and equipment designed considering ergonomics standards. The laboratory studies were simulated in Unity3D platform, which allows the users to control the DHM1 on the dynamic virtual scenario, in order to simulate work activities. This methodology can change the design process by improving the level of interaction between final users, managers and human factor teams. That helps to better visualize future work settings and improve the level of participation between all stakeholders.
Content analysis of 4 to 8 year-old children's dream reports
Sándor, Piroska; Szakadát, Sára; Kertész, Katinka; Bódizs, Róbert
2015-01-01
The role of dreaming in childhood and in adulthood are still equally enigmatic fields yet to be fully explored. However, while there is a consensus at least about the typical content and formal characteristics of adult dream reports, these features are still a matter of debate in the case of young children. Longitudinal developmental laboratory studies concluded that preschoolers' dreams usually depict static images about mostly animals and body states of the dreamer but they basically lack the active representation of the self, human characters, social interactions, dream emotions and motion imagery. Due to methodological arguments these results became the reference points in the literature of developmental dream research, in spite of the significantly different results of numerous recent and relevant studies using extra-laboratory settings. This study aims to establish a methodologically well-controlled and valid way to collect children's dreams for a representative period of time in a familiar home setting to serve as a comparison to the laboratory method. Pre trained parents acted as interviewers in the course of a 6 week-period of dream collection upon morning awakenings. Our results suggest that even preschoolers are likely to represent their own self in an active role (70%) in their mostly kinematic (82%) dream narratives. Their dream reports contain more human, than animal characters (70 and 7% of all dream characters respectively), and social interactions, self-initiated actions, and emotions are usual part of these dreams. These results are rather similar to those of recent extra-laboratory studies, suggesting that methodological issues may strongly interfere with research outcomes especially in the case of preschoolers' dream narratives. We suggest that nighttime awakenings in the laboratory setting could be crucial in understanding the contradictory results of dream studies in case of young children. PMID:25983708
Infection control in cystic fibrosis: barriers to implementation and ideas for improvement.
Saiman, Lisa; Garber, Elizabeth
2009-11-01
This review will focus on recent research documenting baseline adherence to infection control recommendations and barriers to their implementation as experienced by multidisciplinary cystic fibrosis (CF) care providers. In addition, controversies regarding optimal infection control will be discussed. Finally, suggestions to improve infection control in CF will be proposed. Compliance with recent guidelines was assessed for clinical microbiology laboratories and for infection control policies at CF care centers in the United States. Unlike earlier reports, the vast majority of laboratories used selective media for Burkholderia cepacia complex and identified all species of nonlactose fermenting Gram-negative bacilli. Fewer used selective media for Staphylococcus aureus or used agar-based susceptibility testing assays for Pseudomonas aeruginosa. Only 103 (65%) of 158 CF care centers provided written infection control policies for review and these were more likely to address inpatient than outpatient settings. Surveys of healthcare professionals showed that access to a copy of the CF infection control guidelines reduced barriers to adherence to selected infection control practices. These data suggest that access to national infection control guidelines and written local policies are critically important to improving infection control for CF.
A Laboratory Goniometer System for Measuring Reflectance and Emittance Anisotropy
Roosjen, Peter P. J.; Clevers, Jan G. P. W.; Bartholomeus, Harm M.; Schaepman, Michael E.; Schaepman-Strub, Gabriela; Jalink, Henk; van der Schoor, Rob; de Jong, Arjan
2012-01-01
In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers. PMID:23443402
A laboratory goniometer system for measuring reflectance and emittance anisotropy.
Roosjen, Peter P J; Clevers, Jan G P W; Bartholomeus, Harm M; Schaepman, Michael E; Schaepman-Strub, Gabriela; Jalink, Henk; van der Schoor, Rob; de Jong, Arjan
2012-12-13
In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers.
Dobecki, Marek
2012-01-01
This paper reviews the requirements for measurement methods of chemical agents in the air at workstations. European standards, which have a status of Polish standards, comprise some requirements and information on sampling strategy, measuring techniques, type of samplers, sampling pumps and methods of occupational exposure evaluation at a given technological process. Measurement methods, including air sampling and analytical procedure in a laboratory, should be appropriately validated before intended use. In the validation process, selected methods are tested and budget of uncertainty is set up. The validation procedure that should be implemented in the laboratory together with suitable statistical tools and major components of uncertainity to be taken into consideration, were presented in this paper. Methods of quality control, including sampling and laboratory analyses were discussed. Relative expanded uncertainty for each measurement expressed as a percentage, should not exceed the limit of values set depending on the type of occupational exposure (short-term or long-term) and the magnitude of exposure to chemical agents in the work environment.
The African cholera surveillance network (Africhol) consortium meeting, 10-11 June 2015, Lomé, Togo.
Munier, Aline; Njanpop-Lafourcade, Berthe-Marie; Sauvageot, Delphine; Mhlanga, Raymond B; Heyerdahl, Léonard; Nadri, Johara; Wood, Richard; Ouedraogo, Issaka; Blake, Alexandre; Akilimali Mukelenge, Laurent; Anné, Jean-Claude B; Banla Kere, Abiba; Dempouo, Lucienne; Keita, Sakoba; Langa, José P M; Makumbi, Issa; Mwakapeje, Elibariki R; Njeru, Ian J; Ojo, Olubunmi E; Phiri, Isaac; Pezzoli, Lorenzo; Gessner, Bradford D; Mengel, Martin
2017-01-01
The fifth annual meeting of the African cholera surveillance network (Africhol) took place on 10-11 June 2015 in Lomé, Togo. Together with international partners, representatives from the 11 member countries -Cameroon, Côte d'Ivoire, Democratic Republic of Congo, Guinea, Kenya, Mozambique, Nigeria, Tanzania, Togo, Uganda, Zimbabwe- and an invited country (Malawi) shared their experience. The meeting featured three sessions: i) cholera surveillance, prevention and control in participating countries, ii) cholera surveillance methodology, such as cholera mapping, cost-effectiveness studies and the issue of overlapping epidemics from different diseases, iii) cholera laboratory diagnostics tools and capacity building. The meeting has greatly benefitted from the input of technical expertise from participating institutions and the observations emerging from the meeting should enable national teams to make recommendations to their respective governments on the most appropriate and effective measures to be taken for the prevention and control of cholera. Recommendations for future activities included collecting precise burden estimates in surveillance sites; modeling cholera burden for Africa; setting up cross-border collaborations; strengthening laboratory capacity for the confirmation of suspected cholera cases and for vaccine impact assessment in settings where oral cholera vaccine would be used; adapting cholera surveillance to concurrent issues (e.g., Ebola); and developing national cholera control plans including rationale vaccination strategies together with other preventive and control measures such as improvements in water, sanitation and hygiene (WASH).
Syphilis testing in antenatal care: Policies and practices among laboratories in the Americas.
Luu, Minh; Ham, Cal; Kamb, Mary L; Caffe, Sonja; Hoover, Karen W; Perez, Freddy
2015-06-01
To asses laboratory syphilis testing policies and practices among laboratories in the Americas. Laboratory directors or designees from PAHO member countries were invited to participate in a structured, electronically-delivered survey between March and August, 2014. Data on syphilis tests, algorithms, and quality control (QC) practices were analyzed, focusing on laboratories receiving specimens from antenatal clinics (ANCs). Surveys were completed by 69 laboratories representing 30 (86%) countries. Participating laboratories included 36 (52%) national or regional reference labs and 33 (48%) lower-level laboratories. Most (94%) were public sector facilities and 71% reported existence of a national algorithm for syphilis testing in pregnancy, usually involving both treponemal and non-treponemal testing (72%). Less than half (41%) used rapid syphilis tests (RSTs); and only seven laboratories representing five countries reported RSTs were included in the national algorithm for pregnant women. Most (83%) laboratories serving ANCs reported using some type of QC system; 68% of laboratories reported participation in external QC. Only 36% of laboratories reported data to national/local surveillance. Half of all laboratories serving ANC settings reported a stockout of one or more essential supplies during the previous year (median duration, 30days). Updating laboratory algorithms, improving testing standards, integrating data into existing surveillance, and improved procurement and distribution of commodities may be needed to ensure elimination of MTCT of syphilis in the Americas. Copyright © 2015. Published by Elsevier Ireland Ltd.
de Beer, Jessica L.; Kremer, Kristin; Ködmön, Csaba; Supply, Philip
2012-01-01
Although variable-number tandem-repeat (VNTR) typing has gained recognition as the new standard for the DNA fingerprinting of Mycobacterium tuberculosis complex (MTBC) isolates, external quality control programs have not yet been developed. Therefore, we organized the first multicenter proficiency study on 24-locus VNTR typing. Sets of 30 DNAs of MTBC strains, including 10 duplicate DNA samples, were distributed among 37 participating laboratories in 30 different countries worldwide. Twenty-four laboratories used an in-house-adapted method with fragment sizing by gel electrophoresis or an automated DNA analyzer, nine laboratories used a commercially available kit, and four laboratories used other methods. The intra- and interlaboratory reproducibilities of VNTR typing varied from 0% to 100%, with averages of 72% and 60%, respectively. Twenty of the 37 laboratories failed to amplify particular VNTR loci; if these missing results were ignored, the number of laboratories with 100% interlaboratory reproducibility increased from 1 to 5. The average interlaboratory reproducibility of VNTR typing using a commercial kit was better (88%) than that of in-house-adapted methods using a DNA analyzer (70%) or gel electrophoresis (50%). Eleven laboratories using in-house-adapted manual typing or automated typing scored inter- and intralaboratory reproducibilities of 80% or higher, which suggests that these approaches can be used in a reliable way. In conclusion, this first multicenter study has documented the worldwide quality of VNTR typing of MTBC strains and highlights the importance of international quality control to improve genotyping in the future. PMID:22170917
Affirmative action policies promote women and do not harm efficiency in the laboratory.
Balafoutas, Loukas; Sutter, Matthias
2012-02-03
Gender differences in choosing to enter competitions are one source of unequal labor market outcomes concerning wages and promotions. Given that studying the effects of policy interventions to support women is difficult with field data because of measurement problems and potential lack of control, we evaluated, in a set of controlled laboratory experiments, four interventions: quotas, where one of two winners of a competition must be female; two variants of preferential treatment, where a fixed increment is added to women's performance; and repetition of the competition, where a second competition takes place if no woman is among the winners. Compared with no intervention, all interventions encourage women to enter competitions more often, and performance is at least equally good, both during and after the competition.
Grenby, T H; Mistry, M
1995-01-01
A new electronic system was set up for accurately regulating the amount and frequency of food dispensed to laboratory rats so that investigations of the cariogenic potential of foods can be carried out under strictly controlled conditions according to the stipulations of the San Antonio Consensus Conference, 1985. The system was used to evaluate the cariogenicity of sucrose incorporated into plain and milk chocolate. The results suggested that 18.75% of sucrose in the diet had the same cariogenic potential no matter whether it was in the form of fine crystals or incorporated into plain chocolate, but mean caries scores were nearly 30% higher on a plain chocolate than on a milk chocolate regime.
NASA Technical Reports Server (NTRS)
Felberg, F. H.
1984-01-01
The Jet Propulsion Laboratory, a research and development organization with about 5,000 employees, presents a complicated set of requirements for an institutional system of computing and informational services. The approach taken by JPL in meeting this challenge is one of controlled flexibility. A central communications network is provided, together with selected computing facilities for common use. At the same time, staff members are given considerable discretion in choosing the mini- and microcomputers that they believe will best serve their needs. Consultation services, computer education, and other support functions are also provided.
Mass Property Measurements of the Mars Science Laboratory Rover
NASA Technical Reports Server (NTRS)
Fields, Keith
2012-01-01
The NASA/JPL Mars Science Laboratory (MSL) spacecraft mass properties were measured on a spin balance table prior to launch. This paper discusses the requirements and issues encountered with the setup, qualification, and testing using the spin balance table, and the idiosyncrasies encountered with the test system. The final mass measurements were made in the Payload Hazardous Servicing Facility (PHSF) at Kennedy Space Center on the fully assembled and fueled spacecraft. This set of environmental tests required that the control system for the spin balance machine be at a remote location, which posed additional challenges to the operation of the machine
Kilinc Balci, F. Selcen
2016-01-01
Although they play an important role in infection prevention and control, textile materials and personal protective equipment (PPE) used in health care settings are known to be one of the sources of cross-infection. Gowns are recommended to prevent transmission of infectious diseases in certain settings; however, laboratory and field studies have produced mixed results of their efficacy. PPE used in health care is regulated as either class I (low risk) or class II (intermediate risk) devices in the United States. Many organizations have published guidelines for the use of PPE, including isolation gowns, in health care settings. In addition, the Association for the Advancement of Medical Instrumentation published a guidance document on the selection of gowns and a classification standard on liquid barrier performance for both surgical and isolation gowns. However, there is currently no existing standard specific to isolation gowns that considers not only the barrier resistance but also a wide array of end user desired attributes. As a result, infection preventionists and purchasing agents face several difficulties in the selection process, and end users have limited or no information on the levels of protection provided by isolation gowns. Lack of knowledge about the performance of protective clothing used in health care became more apparent during the 2014 Ebola epidemic. This article reviews laboratory studies, regulations, guidelines and standards pertaining to isolation gowns, characterization problems, and other potential barriers of isolation gown selection and use. PMID:26391468
Safety in the Chemical Laboratory: An Undergraduate Chemical Laboratory Safety Course.
ERIC Educational Resources Information Center
Nicholls, L. Jewel
1982-01-01
Describes a two-quarter hour college chemistry course focusing on laboratory safety. Includes lists of topics/assignments, problem sets (toxicology, storage, and energy) and videotapes, films, and slide sets used in the course. (JN)
Christopher Peterson
2010-01-01
BACKGROUND: Termiticides are applied at concentrations much higher than those used in agricultural settings. The longevity of fipronil has not yet been examined at the rates used for termite control, nor has the compoundâs movement in the soil been addressed.
ERIC Educational Resources Information Center
Falkmer, Marita; Bjallmark, Anna; Larsson, Matilda; Falkmer, Torbjorn
2011-01-01
Several studies, using eye tracking methodology, suggest that different visual strategies in persons with autism spectrum conditions, compared with controls, are applied when viewing facial stimuli. Most eye tracking studies are, however, made in laboratory settings with either static (photos) or non-interactive dynamic stimuli, such as video…
Vandenberg, Olivier; Kozlakidis, Zisis; Schrenzel, Jacques; Struelens, Marc Jean; Breuer, Judith
2018-01-01
Many new innovative diagnostic approaches have been made available during the last 10 years with major impact on patient care and public health surveillance. In parallel, to enhance the cost-effectiveness of the clinical microbiology laboratories (CMLs), European laboratory professionals have streamlined their organization leading to amalgamation of activities and restructuring of their professional relationships with clinicians and public health specialists. Through this consolidation process, an operational model has emerged that combines large centralized clinical laboratories performing most tests on one high-throughput analytical platform connected to several distal laboratories dealing locally with urgent analyses at near point of care. The centralization of diagnostic services over a large geographical region has given rise to the concept of regional-scale "microbiology laboratories network." Although the volume-driven cost savings associated with such laboratory networks seem self-evident, the consequence(s) for the quality of patient care and infectious disease surveillance and control remain less obvious. In this article, we describe the range of opportunities that the changing landscape of CMLs in Europe can contribute toward improving the quality of patient care but also the early detection and enhanced surveillance of public health threats caused by infectious diseases. The success of this transformation of health services is reliant on the appropriate preparation in terms of staff, skills, and processes that would be inclusive of stakeholders. In addition, rigorous metrics are needed to set out more concrete laboratory service performance objectives and assess the expected benefits to society in terms of saving lives and preventing diseases.
Building bridges between clinical and forensic toxicology laboratories.
Martin, Bernardino Barcelo; Gomila, Isabel; Noce, Valeria
2018-05-09
Clinical and forensic toxicology can be defined as the two disciplines involved the detection, identification and measurement of xenobiotics in biological and non-biological specimens to help in the diagnosis, treatment, prognosis, prevention of poisonings and to disclose causes and contributory causes of fatal intoxications, respectively. This article explores the close connections between clinical and forensic toxicology in overlapping areas of interest. An update has been carried out of the following seven areas of interest in analytical toxicology: doping control, sudden cardiac death (SCD), brain death, sudden infant death syndrome (SIDS) and Munchausen syndrome by proxy (MSBP), prenatal exposure to drugs and fetal alcohol syndrome (FAS), drug-facilitated crimes (DFC) and intoxications by new psychoactive substances (NPS). While issues such as SCD, SIDS or doping control are investigated mainly in forensic laboratories, other as prenatal exposure to drugs or FAS are mainly treated in clinical laboratories. On the other hand, areas such MSBP, DFC or the intoxications by NPS are of interest in both laboratories. Some of these topics are initially treated in hospital emergency departments, involving clinical laboratories and sometimes lately derived to forensic laboratories. Conversely, cases with initial medical-legal implications and fatalities are directly handled by forensic toxicology, but may trigger further studies in the clinical setting. Many areas of common interest between clinical and forensic laboratories are building bridges between them. The increasing relationships are improving the growth, the reliability and the robustness of both kind of laboratories. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Asynchronous automated electronic laboratory result notifications: a systematic review.
Slovis, Benjamin H; Nahass, Thomas A; Salmasian, Hojjat; Kuperman, Gilad; Vawdrey, David K
2017-11-01
To systematically review the literature pertaining to asynchronous automated electronic notifications of laboratory results to clinicians. PubMed, Web of Science, and the Cochrane Collaboration were queried for studies pertaining to automated electronic notifications of laboratory results. A title review was performed on the primary results, with a further abstract review and full review to produce the final set of included articles. The full review included 34 articles, representing 19 institutions. Of these, 19 reported implementation and design of systems, 11 reported quasi-experimental studies, 3 reported a randomized controlled trial, and 1 was a meta-analysis. Twenty-seven articles included alerts of critical results, while 5 focused on urgent notifications and 2 on elective notifications. There was considerable variability in clinical setting, system implementation, and results presented. Several asynchronous automated electronic notification systems for laboratory results have been evaluated, most from >10 years ago. Further research on the effect of notifications on clinicians as well as the use of modern electronic health records and new methods of notification is warranted to determine their effects on workflow and clinical outcomes. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Umezawa, Taku; Brenninkmeijer, Carl A. M.; Röckmann, Thomas; van der Veen, Carina; Tyler, Stanley C.; Fujita, Ryo; Morimoto, Shinji; Aoki, Shuji; Sowers, Todd; Schmitt, Jochen; Bock, Michael; Beck, Jonas; Fischer, Hubertus; Michel, Sylvia E.; Vaughn, Bruce H.; Miller, John B.; White, James W. C.; Brailsford, Gordon; Schaefer, Hinrich; Sperlich, Peter; Brand, Willi A.; Rothe, Michael; Blunier, Thomas; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.; Rice, Andrew L.; Bergamaschi, Peter; Veidt, Cordelia; Levin, Ingeborg
2018-03-01
We report results from a worldwide interlaboratory comparison of samples among laboratories that measure (or measured) stable carbon and hydrogen isotope ratios of atmospheric CH4 (δ13C-CH4 and δD-CH4). The offsets among the laboratories are larger than the measurement reproducibility of individual laboratories. To disentangle plausible measurement offsets, we evaluated and critically assessed a large number of intercomparison results, some of which have been documented previously in the literature. The results indicate significant offsets of δ13C-CH4 and δD-CH4 measurements among data sets reported from different laboratories; the differences among laboratories at modern atmospheric CH4 level spread over ranges of 0.5 ‰ for δ13C-CH4 and 13 ‰ for δD-CH4. The intercomparison results summarized in this study may be of help in future attempts to harmonize δ13C-CH4 and δD-CH4 data sets from different laboratories in order to jointly incorporate them into modelling studies. However, establishing a merged data set, which includes δ13C-CH4 and δD-CH4 data from multiple laboratories with desirable compatibility, is still challenging due to differences among laboratories in instrument settings, correction methods, traceability to reference materials and long-term data management. Further efforts are needed to identify causes of the interlaboratory measurement offsets and to decrease those to move towards the best use of available δ13C-CH4 and δD-CH4 data sets.
Duewer, D L; Lalonde, S A; Aubin, R A; Fourney, R M; Reeder, D J
1998-05-01
Knowledge of the expected uncertainty in restriction fragment length polymorphism (RFLP) measurements is required for confident exchange of such data among different laboratories. The total measurement uncertainty among all Technical Working Group for DNA Analysis Methods laboratories has previously been characterized and found to be acceptably small. Casework cell line control measurements provided by six Royal Canadian Mounted Police (RCMP) and 30 U.S. commercial, local, state, and Federal forensic laboratories enable quantitative determination of the within-laboratory precision and among-laboratory concordance components of measurement uncertainty typical of both sets of laboratories. Measurement precision is the same in the two countries for DNA fragments of size 1000 base pairs (bp) to 10,000 bp. However, the measurement concordance among the RCMP laboratories is clearly superior to that within the U.S. forensic community. This result is attributable to the use of a single analytical protocol in all RCMP laboratories. Concordance among U.S. laboratories cannot be improved through simple mathematical adjustments. Community-wide efforts focused on improved concordance may be the most efficient mechanism for further reduction of among-laboratory RFLP measurement uncertainty, should the resources required to fully evaluate potential cross-jurisdictional matches become burdensome as the number of RFLP profiles on record increases.
Fried, Ronna; Surman, Craig; Hammerness, Paul; Petty, Carter; Faraone, Stephen; Hyder, Laran; Westerberg, Diana; Small, Jacqueline; Corkum, Lyndsey; Claudat, Kim; Biederman, Joseph
2012-12-30
Despite an extant literature documenting that adults with attention-deficit/hyperactivity disorder (ADHD) are at increased risk for significant difficulties in the workplace, there is little documentation of the underlying factors associated with these impairments. The main aim of this study was to examine specific deficiencies associated with ADHD on workplace performance in a simulated workplace laboratory relative to controls. Participants were 56 non-medicated young adults with DSM-IV ADHD and 63 age- and sex-matched controls without ADHD. Participants spent 10h in a workplace simulation laboratory. Areas assessed included: (1) simulated tasks documented in a government report (SCANS) often required in workplace settings (taxing vigilance; planning; cooperation; attention to detail), (2) observer ratings, and (3) self-reports. Robust findings were found in the statistically significant differences on self-report of ADHD symptoms found between participants with ADHD and controls during all workplace tasks and periods of the workday. Task performance was found to be deficient in a small number of areas, and there were a few statistically significant differences identified by observer ratings. Symptoms reported by participants with ADHD in the simulation including internal restlessness, intolerance of boredom and difficulty maintaining vigilance were significant and could adversely impact workplace performance over the long-term. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Reliability and Validity of Ambulatory Cognitive Assessments
Sliwinski, Martin J.; Mogle, Jacqueline A.; Hyun, Jinshil; Munoz, Elizabeth; Smyth, Joshua M.; Lipton, Richard B.
2017-01-01
Mobile technologies are increasingly used to measure cognitive function outside of traditional clinic and laboratory settings. Although ambulatory assessments of cognitive function conducted in people’s natural environments offer potential advantages over traditional assessment approaches, the psychometrics of cognitive assessment procedures have been understudied. We evaluated the reliability and construct validity of ambulatory assessments of working memory and perceptual speed administered via smartphones as part of an ecological momentary assessment (EMA) protocol in a diverse adult sample (N=219). Results indicated excellent between-person reliability (≥.97) for average scores, and evidence of reliable within-person variability across measurement occasions (.41–.53). The ambulatory tasks also exhibited construct validity, as evidence by their loadings on working memory and perceptual speed factors defined by the in-lab assessments. Our findings demonstrate that averaging across brief cognitive assessments made in uncontrolled naturalistic settings provide measurements that are comparable in reliability to assessments made in controlled laboratory environments. PMID:27084835
A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload
NASA Technical Reports Server (NTRS)
Golub, Leon
1989-01-01
Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.
Skylab D024 thermal control coatings and polymeric films experiment
NASA Technical Reports Server (NTRS)
Lehn, William L.; Hurley, Charles J.
1992-01-01
The Skylab D024 Thermal Control Coatings and Polymeric Films Experiment was designed to determine the effects of the external Skylab space environment on the performance and properties of a wide variety of selected thermal control coatings and polymeric films. Three duplicate sets of thermal control coatings and polymeric films were exposed to the Skylab space environment for varying periods of time during the mission. The specimens were retrieved by the astronauts during extravehicular activities (EVA) and placed in hermetically sealed return containers, recovered, and returned to the Wright Laboratory/Materials Laboratory/WPAFB, Ohio for analysis and evaluation. Postflight analysis of the three sets of recovered thermal control coatings indicated that measured changes in specimen thermo-optical properties were due to a combination of excessive contamination and solar degradation of the contaminant layer. The degree of degradation experienced over-rode, obscured, and compromised the measurement of the degradation of the substrate coatings themselves. Results of the analysis of the effects of exposure on the polymeric films and the contamination observed are also presented. The D024 results were used in the design of the LDEF M0003-5 Thermal Control Materials Experiment. The results are presented here to call to the attention of the many other LDEF experimenters the wealth of directly related, low earth orbit, space environmental exposure data that is available from the ten or more separate experiments that were conducted during the Skylab mission. Results of these experiments offer data on the results of low altitude space exposure on materials recovered from space with exposure longer than typical STS experiments for comparison with the LDEF results.
For Whom the Mind Wanders, and When, Varies Across Laboratory and Daily-Life Settings.
Kane, Michael J; Gross, Georgina M; Chun, Charlotte A; Smeekens, Bridget A; Meier, Matt E; Silvia, Paul J; Kwapil, Thomas R
2017-09-01
Undergraduates ( N = 274) participated in a weeklong daily-life experience-sampling study of mind wandering after being assessed in the lab for executive-control abilities (working memory capacity; attention-restraint ability; attention-constraint ability; and propensity for task-unrelated thoughts, or TUTs) and personality traits. Eight times a day, electronic devices prompted subjects to report on their current thoughts and context. Working memory capacity and attention abilities predicted subjects' TUT rates in the lab, but predicted the frequency of daily-life mind wandering only as a function of subjects' momentary attempts to concentrate. This pattern replicates prior daily-life findings but conflicts with laboratory findings. Results for personality factors also revealed different associations in the lab and daily life: Only neuroticism predicted TUT rate in the lab, but only openness predicted mind-wandering rate in daily life (both predicted the content of daily-life mind wandering). Cognitive and personality factors also predicted dimensions of everyday thought other than mind wandering, such as subjective judgments of controllability of thought. Mind wandering in people's daily environments and TUTs during controlled and artificial laboratory tasks have different correlates (and perhaps causes). Thus, mind-wandering theories based solely on lab phenomena may be incomplete.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sailer, S.J.
This Quality Assurance Project Plan (QAPJP) specifies the quality of data necessary and the characterization techniques employed at the Idaho National Engineering Laboratory (INEL) to meet the objectives of the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) requirements. This QAPJP is written to conform with the requirements and guidelines specified in the QAPP and the associated documents referenced in the QAPP. This QAPJP is one of a set of five interrelated QAPjPs that describe the INEL Transuranic Waste Characterization Program (TWCP). Each of the five facilities participating in the TWCPmore » has a QAPJP that describes the activities applicable to that particular facility. This QAPJP describes the roles and responsibilities of the Idaho Chemical Processing Plant (ICPP) Analytical Chemistry Laboratory (ACL) in the TWCP. Data quality objectives and quality assurance objectives are explained. Sample analysis procedures and associated quality assurance measures are also addressed; these include: sample chain of custody; data validation; usability and reporting; documentation and records; audits and 0385 assessments; laboratory QC samples; and instrument testing, inspection, maintenance and calibration. Finally, administrative quality control measures, such as document control, control of nonconformances, variances and QA status reporting are described.« less
Understanding behavioral responses of fish to pheromones in natural freshwater environments
Johnson, Nicholas S.; Li, Weiming
2010-01-01
There is an abundance of experimental studies and reviews that describe odorant-mediated behaviors of fish in laboratory microcosms, but research in natural field conditions has received considerably less attention. Fish pheromone studies in laboratory settings can be highly productive and allow for controlled experimental designs; however, laboratory tanks and flumes often cannot replicate all the physical, physiological and social contexts associated with natural environments. Field experiments can be a critical step in affirming and enhancing understanding of laboratory discoveries and often implicate the ecological significance of pheromones employed by fishes. When findings from laboratory experiments have been further tested in field environments, often different and sometimes contradictory conclusions are found. Examples include studies of sea lamprey (Petromyzon marinus) mating pheromones and fish alarm substances. Here, we review field research conducted on fish pheromones and alarm substances, highlighting the following topics: (1) contradictory results obtained in laboratory and field experiments, (2) how environmental context and physiological status influences behavior, (3) challenges and constraints of aquatic field research and (4) innovative techniques and experimental designs that advance understanding of fish chemical ecology through field research.
Stachenfeld, Nina S
2014-05-01
Changes in skin blood and sweating are the primary mechanisms for heat loss in humans. A hot, humid environment concomitant with dehydration limits the ability to increase skin blood flow for the purpose of transferring heat from the body core to skin surface and evaporate sweat to maintain core temperature within safe limits during exercise. Adequate hydration improves thermoregulation by maintaining blood volume to support skin blood flow and sweating. Humans rely on fluid intake to maintain total body water and blood volume, and have developed complex mechanisms to sense changes in the amount and composition of fluid in the body. This paper addresses the interrelationship of research in the laboratory and the field to assess hydration status involved in body water and temperature regulation during exercise. In the controlled setting of a research laboratory, investigators are able to investigate the contributions of volume and tonicity of fluid in the plasma to body water and temperature regulation during exercise and recovery. For example, laboratory studies have shown that tonicity in a rehydration beverage maintains the thirst mechanism (and stimulates drinking), and contributes to the ongoing stimulation of renal fluid retention hormones, ultimately leading to a more complete rehydration. Research in the field cannot control the environment precisely, but these studies provide a natural, 'real-life' setting to study fluid and temperature regulation during exercise. The conditions encountered in the field are closest to the environment during competition, and data collected in the field can have an immediate impact on performance and safety during exercise. There is an important synergy between these two methods of collecting data that support performance and protect athletes from harm during training and improve performance during competition.
Jacobsen, Sonja; Patel, Pranav; Schmidt-Chanasit, Jonas; Leparc-Goffart, Isabelle; Teichmann, Anette; Zeller, Herve; Niedrig, Matthias
2016-03-01
Since the re-emergence of Chikungunya virus (CHIKV) in Reunion in 2005 and the recent outbreak in the Caribbean islands with an expansion to the Americas the CHIK diagnostic became very important. We evaluate the performance of laboratories regarding molecular and serological diagnostic of CHIK worldwide. A panel of 12 samples for molecular and 13 samples for serology were provided to 60 laboratories in 40 countries for evaluating the sensitivity and specificity of molecular and serology testing. The panel for molecular diagnostic testing was analysed by 56 laboratories returning 60 data sets of results whereas the 56 and 60 data sets were returned for IgG and IgM diagnostic from the participating laboratories. Twenty-three from 60 data sets performed optimal, 7 acceptable and 30 sets of results require improvement. From 50 data sets only one laboratory shows an optimal performance for IgM detection, followed by 9 data sets with acceptable and the rest need for improvement. From 46 IgG serology data sets 20 provide an optimal, 2 an acceptable and 24 require improvement performance. The evaluation of some of the diagnostic performances allows linking the quality of results to the in-house methods or commercial assays used. The external quality assurance for CHIK diagnostics provides a good overview on the laboratory performance regarding sensitivity and specificity for the molecular and serology diagnostic required for the quick and reliable analysis of suspected CHIK patients. Nearly half of the laboratories have to improve their diagnostic profile to achieve a better performance. Copyright © 2016 Z. Published by Elsevier B.V. All rights reserved.
Blaya, Joaquín A.; Shin, Sonya S.; Yagui, Martin; Contreras, Carmen; Cegielski, Peter; Yale, Gloria; Suarez, Carmen; Asencios, Luis; Bayona, Jaime; Kim, Jihoon; Fraser, Hamish S. F.
2014-01-01
Background Lost, delayed or incorrect laboratory results are associated with delays in initiating treatment. Delays in treatment for Multi-Drug Resistant Tuberculosis (MDR-TB) can worsen patient outcomes and increase transmission. The objective of this study was to evaluate the impact of a laboratory information system in reducing delays and the time for MDR-TB patients to culture convert (stop transmitting). Methods Setting: 78 primary Health Centers (HCs) in Lima, Peru. Participants lived within the catchment area of participating HCs and had at least one MDR-TB risk factor. The study design was a cluster randomized controlled trial with baseline data. The intervention was the e-Chasqui web-based laboratory information system. Main outcome measures were: times to communicate a result; to start or change a patient's treatment; and for that patient to culture convert. Results 1671 patients were enrolled. Intervention HCs took significantly less time to receive drug susceptibility test (DST) (median 11 vs. 17 days, Hazard Ratio 0.67 [0.62–0.72]) and culture (5 vs. 8 days, 0.68 [0.65–0.72]) results. The time to treatment was not significantly different, but patients in intervention HCs took 16 days (20%) less time to culture convert (p = 0.047). Conclusions The eChasqui system reduced the time to communicate results between laboratories and HCs and time to culture conversion. It is now used in over 259 HCs covering 4.1 million people. This is the first randomized controlled trial of a laboratory information system in a developing country for any disease and the only study worldwide to show clinical impact of such a system. Trial Registration ClinicalTrials.gov NCT01201941 PMID:24721980
A new gated x-ray detector for the Orion laser facility
NASA Astrophysics Data System (ADS)
Clark, David D.; Aragonez, Robert; Archuleta, Thomas; Fatherley, Valerie; Hsu, Albert; Jorgenson, Justin; Mares, Danielle; Oertel, John; Oades, Kevin; Kemshall, Paul; Thomas, Phillip; Young, Trevor; Pederson, Neal
2012-10-01
Gated X-Ray Detectors (GXD) are considered the work-horse target diagnostic of the laser based inertial confinement fusion (ICF) program. Recently, Los Alamos National Laboratory (LANL) has constructed three new GXDs for the Orion laser facility at the Atomic Weapons Establishment (AWE) in the United Kingdom. What sets these three new instruments apart from what has previously been constructed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is: improvements in detector head microwave transmission lines, solid state embedded hard drive and updated control software, and lighter air box design and other incremental mechanical improvements. In this paper we will present the latest GXD design enhancements and sample calibration data taken on the Trident laser facility at Los Alamos National Laboratory using the newly constructed instruments.
Achieving external validity in home advantage research: generalizing crowd noise effects
Myers, Tony D.
2014-01-01
Different factors have been postulated to explain the home advantage phenomenon in sport. One plausible explanation investigated has been the influence of a partisan home crowd on sports officials' decisions. Different types of studies have tested the crowd influence hypothesis including purposefully designed experiments. However, while experimental studies investigating crowd influences have high levels of internal validity, they suffer from a lack of external validity; decision-making in a laboratory setting bearing little resemblance to decision-making in live sports settings. This focused review initially considers threats to external validity in applied and theoretical experimental research. Discussing how such threats can be addressed using representative design by focusing on a recently published study that arguably provides the first experimental evidence of the impact of live crowd noise on officials in sport. The findings of this controlled experiment conducted in a real tournament setting offer a level of confirmation of the findings of laboratory studies in the area. Finally directions for future research and the future conduct of crowd noise studies are discussed. PMID:24917839
Crowdsourcing for Cognitive Science – The Utility of Smartphones
Brown, Harriet R.; Zeidman, Peter; Smittenaar, Peter; Adams, Rick A.; McNab, Fiona; Rutledge, Robb B.; Dolan, Raymond J.
2014-01-01
By 2015, there will be an estimated two billion smartphone users worldwide. This technology presents exciting opportunities for cognitive science as a medium for rapid, large-scale experimentation and data collection. At present, cost and logistics limit most study populations to small samples, restricting the experimental questions that can be addressed. In this study we investigated whether the mass collection of experimental data using smartphone technology is valid, given the variability of data collection outside of a laboratory setting. We presented four classic experimental paradigms as short games, available as a free app and over the first month 20,800 users submitted data. We found that the large sample size vastly outweighed the noise inherent in collecting data outside a controlled laboratory setting, and show that for all four games canonical results were reproduced. For the first time, we provide experimental validation for the use of smartphones for data collection in cognitive science, which can lead to the collection of richer data sets and a significant cost reduction as well as provide an opportunity for efficient phenotypic screening of large populations. PMID:25025865
Crowdsourcing for cognitive science--the utility of smartphones.
Brown, Harriet R; Zeidman, Peter; Smittenaar, Peter; Adams, Rick A; McNab, Fiona; Rutledge, Robb B; Dolan, Raymond J
2014-01-01
By 2015, there will be an estimated two billion smartphone users worldwide. This technology presents exciting opportunities for cognitive science as a medium for rapid, large-scale experimentation and data collection. At present, cost and logistics limit most study populations to small samples, restricting the experimental questions that can be addressed. In this study we investigated whether the mass collection of experimental data using smartphone technology is valid, given the variability of data collection outside of a laboratory setting. We presented four classic experimental paradigms as short games, available as a free app and over the first month 20,800 users submitted data. We found that the large sample size vastly outweighed the noise inherent in collecting data outside a controlled laboratory setting, and show that for all four games canonical results were reproduced. For the first time, we provide experimental validation for the use of smartphones for data collection in cognitive science, which can lead to the collection of richer data sets and a significant cost reduction as well as provide an opportunity for efficient phenotypic screening of large populations.
The 2010 Global Proficiency Study of Human Papillomavirus Genotyping in Vaccinology
Eklund, Carina; Forslund, Ola; Wallin, Keng-Ling; Zhou, Tiequn
2012-01-01
Accurate and internationally comparable human papillomavirus (HPV) DNA genotyping is essential both for evaluation of HPV vaccines and for effective monitoring and implementation of vaccination programs. The World Health Organization (WHO) HPV Laboratory Network (LabNet) regularly issues international proficiency studies. The 2010 HPV genotyping proficiency panel for HPV vaccinology contained 43 coded samples composed of purified plasmids of 16 HPV types (HPV types 6, 11, 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, and 68a and 68b) and 3 coded extraction controls. Proficient typing was defined as detection in both single and multiple infections of 50 international units (IU) of HPV type 16 (HPV-16) and HPV-18 DNA and 500 genome equivalents (GE) for the other 14 HPV types. Ninety-eight laboratories worldwide submitted a total of 132 data sets. Twenty-four different HPV genotyping assay methods were used, with Linear Array being the most commonly used. Other major assays used were a line blot assay (Inno-LiPa), CLART, type-specific real-time PCR, PCR Luminex, and different microarray assays. Altogether, 72 data sets were proficient for detection of more than 1 type, and only 26 data sets proficiently detected all 16 HPV types. The major oncogenic HPV types, 16 and 18, were proficiently detected in 95.0% (114/120) and 87.0% (94/108) of data sets, respectively. Forty-six data sets reported multiple false-positive results and were considered nonproficient. A trend toward increased sensitivity of assays was seen for the 41 laboratories that participated in both 2008 and 2010. In conclusion, continued global proficiency studies will be required for establishing comparable and reliable HPV genotyping services for vaccinology worldwide. PMID:22535980
Eklund, Carina; Forslund, Ola; Wallin, Keng-Ling
2014-01-01
Accurate and internationally comparable human papillomavirus (HPV) DNA genotyping is essential for HPV vaccine research and for HPV surveillance. The HPV Laboratory Network (LabNet) has designed international proficiency studies that can be issued regularly and in a reproducible manner. The 2011 HPV genotyping proficiency panel contained 43 coded samples composed of purified plasmids of 16 HPV types (HPV6, -11, -16, -18, -31, -33, -35, -39, -45, -51, -52, -56, -58, -59, -66, -68a, and -68b) and 3 extraction controls. Tests that detected 50 IU of HPV16 and HPV18 and 500 genome equivalents for the other 14 HPV types in both single and multiple infections were considered proficient. Ninety-six laboratories worldwide submitted 134 data sets. Twenty-five different HPV genotyping assay methods were used, including the Linear Array, line blot/INNO-LiPA, PapilloCheck, and PCR Luminex assays. The major oncogenic HPV types, HPV16 and HPV18, were proficiently detected in 97.0% (113/116) and 87.0% (103/118) of the data sets, respectively. In 2011, 51 data sets (39%) were 100% proficient for the detection of at least one HPV type, and 37 data sets (28%) were proficient for all 16 HPV types; this was an improvement over the panel results from the 2008 and 2010 studies, when <25 data sets (23% and 19% for 2008 and 2010, respectively) were fully proficient. The improvement was also evident for the 54 laboratories that had also participated in the previous proficiency studies. In conclusion, a continuing global proficiency program has documented worldwide improvement in the comparability and reliability of HPV genotyping assay performances. PMID:24478473
DOE Office of Scientific and Technical Information (OSTI.GOV)
Satogata, Todd
2013-04-22
The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED databasemore » management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.« less
Measurement of optical blurring in a turbulent cloud chamber
NASA Astrophysics Data System (ADS)
Packard, Corey D.; Ciochetto, David S.; Cantrell, Will H.; Roggemann, Michael C.; Shaw, Raymond A.
2016-10-01
Earth's atmosphere can significantly impact the propagation of electromagnetic radiation, degrading the performance of imaging systems. Deleterious effects of the atmosphere include turbulence, absorption and scattering by particulates. Turbulence leads to blurring, while absorption attenuates the energy that reaches imaging sensors. The optical properties of aerosols and clouds also impact radiation propagation via scattering, resulting in decorrelation from unscattered light. Models have been proposed for calculating a point spread function (PSF) for aerosol scattering, providing a method for simulating the contrast and spatial detail expected when imaging through atmospheres with significant aerosol optical depth. However, these synthetic images and their predicating theory would benefit from comparison with measurements in a controlled environment. Recently, Michigan Technological University (MTU) has designed a novel laboratory cloud chamber. This multiphase, turbulent "Pi Chamber" is capable of pressures down to 100 hPa and temperatures from -55 to +55°C. Additionally, humidity and aerosol concentrations are controllable. These boundary conditions can be combined to form and sustain clouds in an instrumented laboratory setting for measuring the impact of clouds on radiation propagation. This paper describes an experiment to generate mixing and expansion clouds in supersaturated conditions with salt aerosols, and an example of measured imagery viewed through the generated cloud is shown. Aerosol and cloud droplet distributions measured during the experiment are used to predict scattering PSF and MTF curves, and a methodology for validating existing theory is detailed. Measured atmospheric inputs will be used to simulate aerosol-induced image degradation for comparison with measured imagery taken through actual cloud conditions. The aerosol MTF will be experimentally calculated and compared to theoretical expressions. The key result of this study is the proposal of a closure experiment for verification of theoretical aerosol effects using actual clouds in a controlled laboratory setting.
Lubin, Ira M; Aziz, Nazneen; Babb, Lawrence J; Ballinger, Dennis; Bisht, Himani; Church, Deanna M; Cordes, Shaun; Eilbeck, Karen; Hyland, Fiona; Kalman, Lisa; Landrum, Melissa; Lockhart, Edward R; Maglott, Donna; Marth, Gabor; Pfeifer, John D; Rehm, Heidi L; Roy, Somak; Tezak, Zivana; Truty, Rebecca; Ullman-Cullere, Mollie; Voelkerding, Karl V; Worthey, Elizabeth A; Zaranek, Alexander W; Zook, Justin M
2017-05-01
A national workgroup convened by the Centers for Disease Control and Prevention identified principles and made recommendations for standardizing the description of sequence data contained within the variant file generated during the course of clinical next-generation sequence analysis for diagnosing human heritable conditions. The specifications for variant files were initially developed to be flexible with regard to content representation to support a variety of research applications. This flexibility permits variation with regard to how sequence findings are described and this depends, in part, on the conventions used. For clinical laboratory testing, this poses a problem because these differences can compromise the capability to compare sequence findings among laboratories to confirm results and to query databases to identify clinically relevant variants. To provide for a more consistent representation of sequence findings described within variant files, the workgroup made several recommendations that considered alignment to a common reference sequence, variant caller settings, use of genomic coordinates, and gene and variant naming conventions. These recommendations were considered with regard to the existing variant file specifications presently used in the clinical setting. Adoption of these recommendations is anticipated to reduce the potential for ambiguity in describing sequence findings and facilitate the sharing of genomic data among clinical laboratories and other entities. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Implementation of quality management for clinical bacteriology in low-resource settings.
Barbé, B; Yansouni, C P; Affolabi, D; Jacobs, J
2017-07-01
The declining trend of malaria and the recent prioritization of containment of antimicrobial resistance have created a momentum to implement clinical bacteriology in low-resource settings. Successful implementation relies on guidance by a quality management system (QMS). Over the past decade international initiatives were launched towards implementation of QMS in HIV/AIDS, tuberculosis and malaria. To describe the progress towards accreditation of medical laboratories and to identify the challenges and best practices for implementation of QMS in clinical bacteriology in low-resource settings. Published literature, online reports and websites related to the implementation of laboratory QMS, accreditation of medical laboratories and initiatives for containment of antimicrobial resistance. Apart from the limitations of infrastructure, equipment, consumables and staff, QMS are challenged with the complexity of clinical bacteriology and the healthcare context in low-resource settings (small-scale laboratories, attitudes and perception of staff, absence of laboratory information systems). Likewise, most international initiatives addressing laboratory health strengthening have focused on public health and outbreak management rather than on hospital based patient care. Best practices to implement quality-assured clinical bacteriology in low-resource settings include alignment with national regulations and public health reference laboratories, participating in external quality assurance programmes, support from the hospital's management, starting with attainable projects, conducting error review and daily bench-side supervision, looking for locally adapted solutions, stimulating ownership and extending existing training programmes to clinical bacteriology. The implementation of QMS in clinical bacteriology in hospital settings will ultimately boost a culture of quality to all sectors of healthcare in low-resource settings. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
ERIC Educational Resources Information Center
Huk, Thomas; Steinke, Mattias; Floto, Christian
2010-01-01
Within the framework of cognitive learning theories, instructional design manipulations have primarily been investigated under tightly controlled laboratory conditions. We carried out two experiments, where the first experiment was conducted in a restricted system-paced setting and is therefore in line with the majority of empirical studies in the…
ERIC Educational Resources Information Center
Habayeb, Serene; Rich, Brendan; Alvord, Mary K.
2017-01-01
Background: Children with autism spectrum disorders (ASD) often carry co-morbid diagnoses and present with impairing heterogeneous symptomatology (Leyfer et al. in "J Autism Dev Disord" 36(7): 849-861, 2006. doi:10.1007/s10803-006-0123-0). However, research from controlled laboratory settings often fails to examine the vast number of…
The evolution of hillslope strength following large earthquakes
NASA Astrophysics Data System (ADS)
Brain, Matthew; Rosser, Nick; Tunstall, Neil
2017-04-01
Earthquake-induced landslides play an important role in the evolution of mountain landscapes. Earthquake ground shaking triggers near-instantaneous landsliding, but has also been shown to weaken hillslopes, preconditioning them for failure during subsequent seismicity and/or precipitation events. The temporal evolution of hillslope strength during and following primary seismicity, and if and how this ultimately results in failure, is poorly constrained due to the rarity of high-magnitude earthquakes and limited availability of suitable field datasets. We present results obtained from novel geotechnical laboratory tests to better constrain the mechanisms that control strength evolution in Earth materials of differing rheology. We consider how the strength of hillslope materials responds to ground-shaking events of different magnitude and if and how this persists to influence landslide activity during interseismic periods. We demonstrate the role of stress path and stress history, strain rate and foreshock and aftershock sequences in controlling the evolution of hillslope strength and stability. Critically, we show how hillslopes can be strengthened rather than weakened in some settings, challenging conventional assumptions. On the basis of our laboratory data, we consider the implications for earthquake-induced geomorphic perturbations in mountain landscapes over multiple timescales and in different seismogenic settings.
Beermann, Sandra; Allerberger, Franz; Wirtz, Angela; Burger, Reinhard; Hamouda, Osamah
2015-10-01
In 1995, in agreement with the German Federal Ministry of Health, the Robert Koch Institute established a public health microbiology system consisting of national reference centers (NRCs) and consultant laboratories (CLs). The goal was to improve the efficiency of infection protection by advising the authorities on possible measures and to supplement infectious disease surveillance by monitoring selected pathogens that have high public health relevance. Currently, there are 19 NRCs and 40 CLs, each appointed for three years. In 2009, an additional system of national networks of NRCs and CLs was set up in order to enhance effectiveness and cooperation within the national reference laboratory system. The aim of these networks was to advance exchange in diagnostic methods and prevention concepts among reference laboratories and to develop geographic coverage of services. In the last two decades, the German public health laboratory reference system coped with all major infectious disease challenges. The European Union and the European Centre for Disease Prevention and Control (ECDC) are considering implementing a European public health microbiology reference laboratory system. The German reference laboratory system should be well prepared to participate actively in this upcoming endeavor. Copyright © 2015 Elsevier GmbH. All rights reserved.
Study of magnetic perturbations on SEC vidicon tubes. [large space telescope
NASA Technical Reports Server (NTRS)
Long, D. C.; Zucchino, P.; Lowrance, J.
1973-01-01
A laboratory measurements program was conducted to determine the tolerances that must be imposed to achieve optimum performance from SEC-vidicon data sensors in the LST mission. These measurements along with other data were used to formulate recommendations regarding the necessary telemetry and remote control for the television data sensors when in orbit. The study encompassed the following tasks: (1) Conducted laboratory measurements of the perturbations which an external magnetic field produces on a magnetically focused, SEC-vidicon. Evaluated shielding approaches. (2) Experimentally evaluated the effects produced on overall performance by variations of the tube electrode potentials, and the focus, deflection and alignment fields. (3) Recommended the extent of ground control of camera parameters and camera parameter telemetry required for optimizing the performance of the television system in orbit. The experimental data are summarized in a set of graphs.
Prevention of laboratory animal allergy.
Fisher, R; Saunders, W B; Murray, S J; Stave, G M
1998-07-01
Laboratory animal allergy (LAA) is a significant occupational hazard for workers in a number of research settings, including the pharmaceutical industry. Prevention of allergy and asthma is important because the illness can affect health and career. In a major pharmaceutical company, in an effort to prevent LAA, a comprehensive program to reduce exposure to environmental allergens was developed. The program included education, engineering controls, administrative controls, use of personal protective equipment, and medical surveillance. A prospective survey of five years of data was completed to determine the effect of the program on the prevalence and incidence of LAA. After instituting this program, we found that the prevalence of LAA ranged from 12%-22% and that the incidence was reduced to zero during the last two years of observation. We concluded that LAA is preventable through the implementation of a comprehensive effort to reduce exposure to allergens.
Vision-based guidance for an automated roving vehicle
NASA Technical Reports Server (NTRS)
Griffin, M. D.; Cunningham, R. T.; Eskenazi, R.
1978-01-01
A controller designed to guide an automated vehicle to a specified target without external intervention is described. The intended application is to the requirements of planetary exploration, where substantial autonomy is required because of the prohibitive time lags associated with closed-loop ground control. The guidance algorithm consists of a set of piecewise-linear control laws for velocity and steering commands, and is executable in real time with fixed-point arithmetic. The use of a previously-reported object tracking algorithm for the vision system to provide position feedback data is described. Test results of the control system on a breadboard rover at the Jet Propulsion Laboratory are included.
Wiers, Reinout W; Boffo, Marilisa; Field, Matt
2018-05-01
Recently, the National Institutes of Health (NIH) redefined clinical trials to include any study involving behavioral or biomedical interventions. In line with a general framework from experimental medicine, we argue that it is crucial to distinguish between experimental laboratory studies aimed at revealing psychological mechanisms underlying behavior and randomized controlled trials (RCTs) in clinical samples aimed at testing the efficacy of an intervention. As an illustration, we reviewed the current state of the evidence on the efficacy of cognitive bias modification (CBM) interventions in alcohol use disorders. A recent meta-analysis "cast serious doubts on the clinical utility of CBM interventions for addiction." That analysis combined experimental laboratory studies and RCTs. We demonstrated that, when studies are differentiated regarding study type (experimental laboratory study or RCT), mode of delivery (controlled experiment or Internet), and population (healthy volunteers or patients), the following effects are found: (a) short-lived effects of CBM on drinking behavior in experimental laboratory studies in students, but only when the bias is successfully manipulated; (b) small but robust effects of CBM on treatment outcome when administered as an adjunct to established treatments in clinical settings in RCTs with alcohol-dependent patients; and (c) nonspecific effects (reduced drinking irrespective of condition) in RCTs of CBM administered online to problem drinkers. We discuss how CBM might be improved when it is better integrated into regular treatment, especially cognitive behavioral therapy, and we conclude that disregarding the difference between experimental laboratory studies and RCTs can lead to invalid conclusions.
RAMP: A fault tolerant distributed microcomputer structure for aircraft navigation and control
NASA Technical Reports Server (NTRS)
Dunn, W. R.
1980-01-01
RAMP consists of distributed sets of parallel computers partioned on the basis of software and packaging constraints. To minimize hardware and software complexity, the processors operate asynchronously. It was shown that through the design of asymptotically stable control laws, data errors due to the asynchronism were minimized. It was further shown that by designing control laws with this property and making minor hardware modifications to the RAMP modules, the system became inherently tolerant to intermittent faults. A laboratory version of RAMP was constructed and is described in the paper along with the experimental results.
Practical methodological guide for hydrometric inter-laboratory organisation
NASA Astrophysics Data System (ADS)
Besson, David; Bertrand, Xavier
2015-04-01
Discharge measurements performed by the French governmental hydrometer team feed a national database. This data is available for general river flows knowkedge, flood forecasting, low water survey, statistical calculations flow, control flow regulatory and many other uses. Regularly checking the measurements quality and better quantifying its accuracy is therefore an absolute need. The practice of inter-laboratory comparison in hydrometry particularly developed during the last decade. Indeed, discharge measurement can not easily be linked to a standard. Therefore, on-site measurement accuracy control is very difficult. Inter-laboratory comparison is thus a practical solution to this issue. However, it needs some regulations in order to ease its practice and legitimize its results. To do so, the French government hydrometrics teams produced a practical methodological guide for hydrometric inter-laboratory organisation in destination of hydrometers community in view of ensure the harmonization of inter-laboratory comparison practices for different materials (ADCP, current meter on wadind rod or gauging van, tracer dilution, surface speed) and flow range (flood, low water). Ensure the results formalization and banking. The realisation of this practice guide is grounded on the experience of the governmental teams & their partners (or fellows), following existing approaches (Doppler group especially). The guide is designated to validate compliance measures and identify outliers : Hardware, methodological, environmental, or human. Inter-laboratory comparison provides the means to verify the compliance of the instruments (devices + methods + operators) and provides methods to determine an experimental uncertainty of the tested measurement method which is valid only for the site and the measurement conditions but does not address the calibration or periodic monitoring of the few materials. After some conceptual definitions, the guide describes the different stages of an inter-comparison campaign: the campaing creation: targets, participants ( instruments type and number) and site preparation of test protocols and schedule; the campaign set-up (organization): invitation and pre-information of the participants, logistics, field preparation; the campaign conduct: participants reception and information, sequences of tests, results analysis and communication, balance sheet; post-campaign work: further analysis, dissemination and periodic verification of the instruments. This guide is associated with measurement instruments forms, reminding their limits and conditions for use, land forms, used to record all the necessary information during the inter-comparison campaign (site description and measurement conditions, equipment and its settings, and the set of measurements or intermediate calculations to the final results) as well as a calculation tool and banking measures and results.
Experimental operation of a sodium heat pipe
NASA Astrophysics Data System (ADS)
Holtz, R. E.; McLennan, G. A.; Koehl, E. R.
1985-05-01
This report documents the operation of a 28 in. long sodium heat pipe in the Heat Pipe Test Facility (HPTF) installed at Argonne National Laboratory. Experimental data were collected to simulate conditions prototypic of both a fluidized bed coal combustor application and a space environment application. Both sets of experiment data show good agreement with the heat pipe analytical model. The heat transfer performance of the heat pipe proved reliable over a substantial period of operation and over much thermal cycling. Additional testing of longer heat pipes under controlled laboratory conditions will be necessary to determine performance limitations and to complete the design code validation.
Schouteten, Joachim J; De Steur, Hans; Sas, Benedikt; De Bourdeaudhuij, Ilse; Gellynck, Xavier
2017-01-01
Although sensory and emotional evaluation of food products mostly occurs in a controlled laboratory environment, it is often criticized as it may not reflect a realistic situation for consumers. Moreover, products are mainly blind evaluated by participants, whereas external factors such as brand are often considered as key drivers of food choice. This study aims to examine the role of research setting (central location test versus home-use test) and brand information on the overall acceptance, and sensory and emotional profiling of 5 strawberry-flavored yogurts. Thereby, private label and premium brands are compared under 3 conditions: blind, expected, and informed (brand information). A total of 99 adult subjects participated in 3 sessions over 3 consecutive weeks. Results showed that overall liking for 2 yogurt samples was higher in the laboratory environment under the informed evaluation condition, whereas no effect of research setting was found under the blind and expected conditions. Although emotional profiles of the products differed depending on the research setting, this was less the case for the sensory profiles. Furthermore, brand information clearly affected the sensory perception of certain attributes but had less influence on overall liking and emotional profiling. These results indicate that both scientists and food companies should consider the effect of the chosen methodology on ecological validity when conducting sensory research with consumers because the laboratory context could lead to a more positive evaluation compared with a home-use test. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Vandenberg, Olivier; Kozlakidis, Zisis; Schrenzel, Jacques; Struelens, Marc Jean; Breuer, Judith
2018-01-01
Many new innovative diagnostic approaches have been made available during the last 10 years with major impact on patient care and public health surveillance. In parallel, to enhance the cost-effectiveness of the clinical microbiology laboratories (CMLs), European laboratory professionals have streamlined their organization leading to amalgamation of activities and restructuring of their professional relationships with clinicians and public health specialists. Through this consolidation process, an operational model has emerged that combines large centralized clinical laboratories performing most tests on one high-throughput analytical platform connected to several distal laboratories dealing locally with urgent analyses at near point of care. The centralization of diagnostic services over a large geographical region has given rise to the concept of regional-scale “microbiology laboratories network.” Although the volume-driven cost savings associated with such laboratory networks seem self-evident, the consequence(s) for the quality of patient care and infectious disease surveillance and control remain less obvious. In this article, we describe the range of opportunities that the changing landscape of CMLs in Europe can contribute toward improving the quality of patient care but also the early detection and enhanced surveillance of public health threats caused by infectious diseases. The success of this transformation of health services is reliant on the appropriate preparation in terms of staff, skills, and processes that would be inclusive of stakeholders. In addition, rigorous metrics are needed to set out more concrete laboratory service performance objectives and assess the expected benefits to society in terms of saving lives and preventing diseases. PMID:29457001
Long Duration Exposure Facility M0003-5 thermal control coatings on DoD flight experiment
NASA Technical Reports Server (NTRS)
Hurley, Charles J.; Lehn, William L.
1992-01-01
The M0003-5 thermal control coatings and materials orbited on the LDEF M0003 Space Environment Effects on Spacecraft Materials were a part of a Wright Laboratories Materials Directorate larger experiment. They were selected from new materials which emerged from development programs during the 1978-1982 time frame. Included were materials described in the technical literature which were being considered or had been applied to satellites. Materials that had been exposed on previous satellite materials experiments were also included to provide data correlation with earlier space flight experiments. The objective was to determine the effect of the LDEF environment on the physical and optical properties of thermal control coatings and materials. One hundred and two specimens of various pigmented organic and inorganic coatings, metallized polymer thin films, optical solar reflectors, and mirrors were orbited on LDEF. The materials were exposed in four separate locations on the vehicle. The first set was exposed on the direct leading edge of the satellite. The second set was exposed on the direct trailing edge of the vehicle. The third and fourth sets were exposed in environmental exposure control canisters (EECC) located 30 degrees off normal to the leading and trailing edges. The purpose of the experiment was to understand the changes in the properties of materials before and after exposure to the space environment and to compare the changes with predictions based on laboratory experiments. The basic approach was to measure the optical and physical properties of materials before and after long-term exposure to a low earth orbital environment comprised of UV, VUV, electrons, protons, atomic oxygen, thermal cycling, vacuum, debris, and micrometeoroids. Due to the unanticipated extended orbital flight of LDEF, the thermal control coatings and materials in the direct leading and trailing edge were exposed for a full five years and ten months to the space environment and the canister materials were exposed for approximately one year to the full environment.
Junker, M H; Danuser, B; Monn, C; Koller, T
2001-10-01
The objective of this study was to provide a basis for effectively protecting nonsmokers from acute sensory impacts and for preventing deterioration of indoor air quality caused by environmental tobacco smoke (ETS) emissions. With an olfactory experiment we determined odor detection thresholds (OT) of sidestream ETS (sETS), and with a full-body exposure experiment we investigated sensory symptoms at very low sETS exposure concentrations. OT concentrations for sETS are three and more orders of magnitude lower than ETS concentrations measured in field settings and correspond to a fresh air dilution volume of > 19,000 m(3) per cigarette, over 100 times more than had previously been suggested for acceptable indoor air conditions. Eye and nasal irritations were observed at one order of magnitude lower sETS concentrations than previously reported, corresponding to a fresh air dilution volume of > 3,000 m(3) per cigarette. These findings have great practical implications for defining indoor air quality standards in indoor compartments where ETS emissions occur. Our study strongly supports the implementation and control of smoking policies such as segregating smoking areas from areas where smoking is not permitted or instituting smoking bans in public buildings.
DeLisi, Nicholas A.; Danka, Robert G.; Walker, Todd W.; Ottea, James A.; Healy, Kristen B.
2018-01-01
Few studies have examined the impact of mosquito adulticides on honey bees under conditions that reflect actual field exposure. Whereas several studies have evaluated the toxicity of mosquito control products on honey bees, most have been laboratory based and have focused solely on acute mortality as a measure of impact. The goal of this study was to determine effects of routine applications of truck-based ultra-low volume (ULV) mosquito adulticides (i.e., Scourge, Duet, and Deltagard) on honey bees in a suburban setting. The mosquito adulticides used in this study were pyrethroids with active ingredients resmethrin (Scourge), prallethrin and sumithrin (Duet), and deltamethrin (Deltagard), in which resmethrin, prallethrin, and sumithrin were synergized with piperonyl butoxide. We measured and compared mortality and detoxification enzyme activities (esterase and glutathione S-transferase) from sentinel beehives within and outside of mosquito control areas. Concurrently, colony health (i.e., number of adult bees, brood quantity and brood quality) was compared throughout the study period. No significant differences were observed in honey bee mortality, colony health or detoxification enzyme activities between treated (five sprayed areas each received one to three insecticide treatment) and control sites (four unsprayed areas that did not receive insecticide treatment) over the seven week study period. However, our laboratory study showed that exposure to resmethrin, the active ingredient in Scourge, caused significant inhibition of esterase activity compared with the control group. Our findings suggest that proper application of truck based insecticides for mosquito control results in little or no exposure and therefore minimal effects on domestic honey bees. PMID:29494661
Pokhrel, Vivek; DeLisi, Nicholas A; Danka, Robert G; Walker, Todd W; Ottea, James A; Healy, Kristen B
2018-01-01
Few studies have examined the impact of mosquito adulticides on honey bees under conditions that reflect actual field exposure. Whereas several studies have evaluated the toxicity of mosquito control products on honey bees, most have been laboratory based and have focused solely on acute mortality as a measure of impact. The goal of this study was to determine effects of routine applications of truck-based ultra-low volume (ULV) mosquito adulticides (i.e., Scourge, Duet, and Deltagard) on honey bees in a suburban setting. The mosquito adulticides used in this study were pyrethroids with active ingredients resmethrin (Scourge), prallethrin and sumithrin (Duet), and deltamethrin (Deltagard), in which resmethrin, prallethrin, and sumithrin were synergized with piperonyl butoxide. We measured and compared mortality and detoxification enzyme activities (esterase and glutathione S-transferase) from sentinel beehives within and outside of mosquito control areas. Concurrently, colony health (i.e., number of adult bees, brood quantity and brood quality) was compared throughout the study period. No significant differences were observed in honey bee mortality, colony health or detoxification enzyme activities between treated (five sprayed areas each received one to three insecticide treatment) and control sites (four unsprayed areas that did not receive insecticide treatment) over the seven week study period. However, our laboratory study showed that exposure to resmethrin, the active ingredient in Scourge, caused significant inhibition of esterase activity compared with the control group. Our findings suggest that proper application of truck based insecticides for mosquito control results in little or no exposure and therefore minimal effects on domestic honey bees.
EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols
Kalina, T; Flores-Montero, J; van der Velden, V H J; Martin-Ayuso, M; Böttcher, S; Ritgen, M; Almeida, J; Lhermitte, L; Asnafi, V; Mendonça, A; de Tute, R; Cullen, M; Sedek, L; Vidriales, M B; Pérez, J J; te Marvelde, J G; Mejstrikova, E; Hrusak, O; Szczepański, T; van Dongen, J J M; Orfao, A
2012-01-01
The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database. PMID:22948490
An underwater robo-leader for collective motion studies
NASA Astrophysics Data System (ADS)
Sanchez, Yair; Wilhelmus, Monica M.
2016-11-01
A wide range of aquatic species, from bacteria to large tuna, exhibits collective behavior. It has long been hypothesized that the formation of complex configurations brings an energetic advantage to the members of a group as well as protection against larger predators or harmful agents. Lately, however, laboratory experiments have suggested that both the physics and the behavioral aspects of collective motion yield more complexity than previously attributed. With the goal to understand the fluid mechanical implications behind collective motion in a laboratory setting, we have developed a new device to induce this behavior on demand. Following recent studies of lab-induced vertical migration of Artemia salina, we have designed and constructed a remotely controlled underwater robotic swimmer that acts as a leader for groups of phototactic organisms. Preliminary quantitative flow visualizations done during vertical migration of brine shrimp show that this new instrument does induce collective motion in the laboratory. With this setup, we can address the hydrodynamic effect of having different swarm configurations, a variable that so far has been challenging to study in a controllable and reproducible manner.
Awais, Muhammad; Palmerini, Luca; Bourke, Alan K.; Ihlen, Espen A. F.; Helbostad, Jorunn L.; Chiari, Lorenzo
2016-01-01
The popularity of using wearable inertial sensors for physical activity classification has dramatically increased in the last decade due to their versatility, low form factor, and low power requirements. Consequently, various systems have been developed to automatically classify daily life activities. However, the scope and implementation of such systems is limited to laboratory-based investigations. Furthermore, these systems are not directly comparable, due to the large diversity in their design (e.g., number of sensors, placement of sensors, data collection environments, data processing techniques, features set, classifiers, cross-validation methods). Hence, the aim of this study is to propose a fair and unbiased benchmark for the field-based validation of three existing systems, highlighting the gap between laboratory and real-life conditions. For this purpose, three representative state-of-the-art systems are chosen and implemented to classify the physical activities of twenty older subjects (76.4 ± 5.6 years). The performance in classifying four basic activities of daily life (sitting, standing, walking, and lying) is analyzed in controlled and free living conditions. To observe the performance of laboratory-based systems in field-based conditions, we trained the activity classification systems using data recorded in a laboratory environment and tested them in real-life conditions in the field. The findings show that the performance of all systems trained with data in the laboratory setting highly deteriorates when tested in real-life conditions, thus highlighting the need to train and test the classification systems in the real-life setting. Moreover, we tested the sensitivity of chosen systems to window size (from 1 s to 10 s) suggesting that overall accuracy decreases with increasing window size. Finally, to evaluate the impact of the number of sensors on the performance, chosen systems are modified considering only the sensing unit worn at the lower back. The results, similarly to the multi-sensor setup, indicate substantial degradation of the performance when laboratory-trained systems are tested in the real-life setting. This degradation is higher than in the multi-sensor setup. Still, the performance provided by the single-sensor approach, when trained and tested with real data, can be acceptable (with an accuracy above 80%). PMID:27973434
McAuliffe, Alan; McGann, Marek
2016-01-01
Speelman and McGann’s (2013) examination of the uncritical way in which the mean is often used in psychological research raises questions both about the average’s reliability and its validity. In the present paper, we argue that interrogating the validity of the mean involves, amongst other things, a better understanding of the person’s experiences, the meaning of their actions, at the time that the behavior of interest is carried out. Recently emerging approaches within Psychology and Cognitive Science have argued strongly that experience should play a more central role in our examination of behavioral data, but the relationship between experience and behavior remains very poorly understood. We outline some of the history of the science on this fraught relationship, as well as arguing that contemporary methods for studying experience fall into one of two categories. “Wide” approaches tend to incorporate naturalistic behavior settings, but sacrifice accuracy and reliability in behavioral measurement. “Narrow” approaches maintain controlled measurement of behavior, but involve too specific a sampling of experience, which obscures crucial temporal characteristics. We therefore argue for a novel, mid-range sampling technique, that extends Hurlburt’s descriptive experience sampling, and adapts it for the controlled setting of the laboratory. This controlled descriptive experience sampling may be an appropriate tool to help calibrate both the mean and the meaning of an experimental situation with one another. PMID:27242588
Measuring and Modeling Behavioral Decision Dynamics in Collective Evacuation
Carlson, Jean M.; Alderson, David L.; Stromberg, Sean P.; Bassett, Danielle S.; Craparo, Emily M.; Guiterrez-Villarreal, Francisco; Otani, Thomas
2014-01-01
Identifying and quantifying factors influencing human decision making remains an outstanding challenge, impacting the performance and predictability of social and technological systems. In many cases, system failures are traced to human factors including congestion, overload, miscommunication, and delays. Here we report results of a behavioral network science experiment, targeting decision making in a natural disaster. In a controlled laboratory setting, our results quantify several key factors influencing individual evacuation decision making in a controlled laboratory setting. The experiment includes tensions between broadcast and peer-to-peer information, and contrasts the effects of temporal urgency associated with the imminence of the disaster and the effects of limited shelter capacity for evacuees. Based on empirical measurements of the cumulative rate of evacuations as a function of the instantaneous disaster likelihood, we develop a quantitative model for decision making that captures remarkably well the main features of observed collective behavior across many different scenarios. Moreover, this model captures the sensitivity of individual- and population-level decision behaviors to external pressures, and systematic deviations from the model provide meaningful estimates of variability in the collective response. Identification of robust methods for quantifying human decisions in the face of risk has implications for policy in disasters and other threat scenarios, specifically the development and testing of robust strategies for training and control of evacuations that account for human behavior and network topologies. PMID:24520331
Activities of the Korean Institute of Tuberculosis
Ryoo, Sungweon; Kim, Hee Jin
2014-01-01
The Korean National Tuberculosis Association (KNTA) set up the Korean Institute of Tuberculosis (KIT) in 1970 to foster research and technical activities pertaining to tuberculosis (TB). The KNTA/KIT had successfully conducted a countrywide TB prevalence survey from 1965 to 1995 at 5-year intervals. The survey results (decline in TB rates) established Korea as a country that had successfully implemented national control programs for TB. The KIT developed the Korea Tuberculosis Surveillance System and the Laboratory Management Information System, both of which were transferred to the Korea Centers for Disease Control and Prevention after its establishment. The KIT functions as a central and supranational reference TB laboratory for microbiological and epidemiological research and provides training and education for health-care workers and medical practitioners. Recently, the KIT has expanded its activities to countries such as Ethiopia, Laos, and Timor-Leste to support TB control and prevention. The KIT will continue to support research activities and provide technical assistance in diagnosing the infection until it is completely eliminated in Korea. PMID:25861580
Remote Control and Data Acquisition: A Case Study
NASA Technical Reports Server (NTRS)
DeGennaro, Alfred J.; Wilkinson, R. Allen
2000-01-01
This paper details software tools developed to remotely command experimental apparatus, and to acquire and visualize the associated data in soft real time. The work was undertaken because commercial products failed to meet the needs. This work has identified six key factors intrinsic to development of quality research laboratory software. Capabilities include access to all new instrument functions without any programming or dependence on others to write drivers or virtual instruments, simple full screen text-based experiment configuration and control user interface, months of continuous experiment run-times, order of 1% CPU load for condensed matter physics experiment described here, very little imposition of software tool choices on remote users, and total remote control from anywhere in the world over the Internet or from home on a 56 Kb modem as if the user is sitting in the laboratory. This work yielded a set of simple robust tools that are highly reliable, resource conserving, extensible, and versatile, with a uniform simple interface.
Ki, Chang Seok; Lee, Hyukmin; Sung, Heungsup; Kim, Sinyoung; Seong, Moon Woo; Yong, Dongeun; Kim, Jae Seok; Lee, Mi Kyung; Kim, Mi Na; Choi, Jong Rak; Kim, Jeong Ho
2016-05-01
For two months between May and July 2015, a nationwide outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) occurred in Korea. On June 3, 2015, the Korean Society for Laboratory Medicine (KSLM) launched a MERS-CoV Laboratory Response Task Force (LR-TF) to facilitate clinical laboratories to set up the diagnosis of MERS-CoV infection. Based on the WHO interim recommendations, the Centers for Disease Control and Prevention of United States guidelines for MERS-CoV laboratory testing, and other available resources, the KSLM MERS-CoV LR-TF provided the first version of the laboratory practice guidelines for the molecular diagnosis of MERS-CoV to the clinical laboratories on June 12, 2015. The guidelines described here are an updated version that includes case definition, indications for testing, specimen type and protocols for specimen collection, specimen packing and transport, specimen handling and nucleic acid extraction, molecular detection of MERS-CoV, interpretation of results and reporting, and laboratory safety. The KSLM guidelines mainly focus on the molecular diagnosis of MERS-CoV, reflecting the unique situation in Korea and the state of knowledge at the time of publication.
Implementation of 5S Method for Ergonomic Laboratory
NASA Astrophysics Data System (ADS)
Dila Sari, Amarria; Ilma Rahmillah, Fety; Prabowo Aji, Bagus
2017-06-01
This article discusses 5S implementation in Work System Design and Ergonomic Laboratory, Department of Industrial Engineering, Islamic University of Indonesia. There are some problems related to equipment settings for activity involving students such as files which is accumulated over the previous year practicum, as well as the movement of waste in the form of time due to the placement of goods that do not fit. Therefore, this study aims to apply the 5S method in DSK & E laboratory to facilitate the work processes and reduce waste. The project is performed by laboratory management using 5S methods in response to continuous improvement (Kaizen). Moreover, some strategy and suggestions are promoted to impose 5S system within the laboratory. As a result, the tidiness and cleanliness can be achieved that lead to the great performance of laboratory users. Score assessment before implementing 5S DSKE laboratory is at 64 (2.56) while the score after implementation is 32 (1.28) and shows an improvement of 50%. This has implications for better use in the laboratory area, save time when looking for tools and materials due to its location and good visual control, as well as improving the culture and spirit of ‘5S’ on staff regarding better working environment
Internal audit in a microbiology laboratory.
Mifsud, A J; Shafi, M S
1995-01-01
AIM--To set up a programme of internal laboratory audit in a medical microbiology laboratory. METHODS--A model of laboratory based process audit is described. Laboratory activities were examined in turn by specimen type. Standards were set using laboratory standard operating procedures; practice was observed using a purpose designed questionnaire and the data were analysed by computer; performance was assessed at laboratory audit meetings; and the audit circle was closed by re-auditing topics after an interval. RESULTS--Improvements in performance scores (objective measures) and in staff morale (subjective impression) were observed. CONCLUSIONS--This model of process audit could be applied, with amendments to take local practice into account, in any microbiology laboratory. PMID:7665701
Laboratory challenges conducting international clinical research in resource-limited settings.
Fitzgibbon, Joseph E; Wallis, Carole L
2014-01-01
There are many challenges to performing clinical research in resource-limited settings. Here, we discuss several of the most common laboratory issues that must be addressed. These include issues relating to organization and personnel, laboratory facilities and equipment, standard operating procedures, external quality assurance, shipping, laboratory capacity, and data management. Although much progress has been made, innovative ways of addressing some of these issues are still very much needed.
2014-01-01
Several online forums exist to facilitate open and/or anonymous discussion of the peer-reviewed scientific literature. Data integrity is a common discussion topic, and it is widely assumed that publicity surrounding such matters will accelerate correction of the scientific record. This study aimed to test this assumption by examining a collection of 497 papers for which data integrity had been questioned either in public or in private. As such, the papers were divided into two sub-sets: a public set of 274 papers discussed online, and the remainder a private set of 223 papers not publicized. The sources of alleged data problems, as well as criteria for defining problem data, and communication of problems to journals and appropriate institutions, were similar between the sets. The number of laboratory groups represented in each set was also similar (75 in public, 62 in private), as was the number of problem papers per laboratory group (3.65 in public, 3.54 in private). Over a study period of 18 months, public papers were retracted 6.5-fold more, and corrected 7.7-fold more, than those in the private set. Parsing the results by laboratory group, 28 laboratory groups in the public set had papers which received corrective action, versus 6 laboratory groups in the private set. For those laboratory groups in the public set with corrected/retracted papers, the fraction of their papers acted on was 62% of those initially flagged, whereas in the private set this fraction was 27%. Such clustering of actions suggests a pattern in which correction/retraction of one paper from a group correlates with more corrections/retractions from the same group, with this pattern being stronger in the public set. It is therefore concluded that online discussion enhances levels of corrective action in the scientific literature. Nevertheless, anecdotal discussion reveals substantial room for improvement in handling of such matters. PMID:24765564
de Witt Huberts, Jessie; Greenland, Katie; Schmidt, Wolf-Peter; Curtis, Val
2016-07-01
The purpose of this review was to understand whether adding antimicrobial agents to hand hygiene products could increase the health benefits of handwashing with plain soap (HWWS) in low-income settings. A review of experimental studies comparing the effects of HWWS with antimicrobial soap and waterless hand sanitizer on health and hand contamination in naturalistic conditions was conducted. In addition, an analysis was completed of the evidence from laboratory studies examining the factors that may affect the impact of antimicrobial soap, taking into account the conditions in low-income settings. The review found no evidence for a superior effect of antimicrobial products compared with HWWS on disease incidence and limited evidence for an effect on hand contamination under naturalistic conditions. An analysis of the effectiveness of antimicrobial soap in laboratory settings suggested that it was only more effective than HWWS when handwashing frequency, duration, and product concentrations were above levels that could be expected in low-income settings. The limited available evidence suggests that under naturalistic conditions, antimicrobial products are no more effective than HWWS in removing pathogens from hands. Without significant improvement in efficacy, antimicrobial products are unlikely to produce greater health gains than HWWS in low-income settings. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
PCDAQ, A Windows Based DAQ System
NASA Astrophysics Data System (ADS)
Hogan, Gary
1998-10-01
PCDAQ is a Windows NT based general DAQ/Analysis/Monte Carlo shell developed as part of the Proton Radiography project at LANL (Los Alamos National Laboratory). It has been adopted by experiments outside of the Proton Radiography project at Brookhaven National Laboratory (BNL) and at LANL. The program provides DAQ, Monte Carlo, and replay (disk file input) modes. Data can be read from hardware (CAMAC) or other programs (ActiveX servers). Future versions will read VME. User supplied data analysis routines can be written in Fortran, C++, or Visual Basic. Histogramming, testing, and plotting packages are provided. Histogram data can be exported to spreadsheets or analyzed in user supplied programs. Plots can be copied and pasted as bitmap objects into other Windows programs or printed. A text database keyed by the run number is provided. Extensive software control flags are provided so that the user can control the flow of data through the program. Control flags can be set either in script command files or interactively. The program can be remotely controlled and data accessed over the Internet through its ActiveX DCOM interface.
Are we drunk yet? Motor versus cognitive cues of subjective intoxication.
Celio, Mark A; Usala, Julie M; Lisman, Stephen A; Johansen, Gerard E; Vetter-O'Hagen, Courtney S; Spear, Linda P
2014-02-01
Perception of alcohol intoxication presumably plays an important role in guiding behavior during a current drinking episode. Yet, there has been surprisingly little investigation of what aspects associated with intoxication are used by individuals to attribute their level of intoxication. Building on recent laboratory-based findings, this study employed a complex field-based design to explore the relative contributions of motor performance versus cognitive performance-specifically executive control-on self-attributions of intoxication. Individuals recruited outside of bars (N = 280; mean age = 22; range: 18 to 32) completed a structured interview, self-report questionnaire, and neuropsychological testing battery, and provided a breath alcohol concentration (BrAC) sample. Results of a multiple linear regression analysis demonstrated that current level of subjective intoxication was associated with current alcohol-related stimulant effects, current sedative effects, and current BrAC. After controlling for the unique variance accounted for by these factors, subjective intoxication was better predicted by simple motor speed, as indexed by performance on the Finger Tapping Test, than by executive control, as indexed by performance on the Trail Making Test. These results-generated from data collected in a naturally occurring setting-support previous findings from a more traditional laboratory-based investigation, thus illustrating the iterative process of linking field methodology and controlled laboratory experimentation. Copyright © 2013 by the Research Society on Alcoholism.
Time lapse of CIR rack rotate and R&R
2014-07-21
ISS040-E-071994 (21 July 2014) --- In the International Space Station’s Destiny laboratory, NASA astronaut Reid Wiseman, Expedition 40 flight engineer, sets up the Combustion Integrated Rack (CIR) for more ground-commanded tests. This facility, which includes an optics bench, combustion chamber, fuel and oxidizer control and five different cameras, allows a variety of combustion experiments to be performed safely aboard the station.
Time lapse of CIR rack rotate and R&R
2014-07-21
ISS040-E-072156 (21 July 2014) --- In the International Space Station’s Destiny laboratory, NASA astronaut Reid Wiseman, Expedition 40 flight engineer, sets up the Combustion Integrated Rack (CIR) for more ground-commanded tests. This facility, which includes an optics bench, combustion chamber, fuel and oxidizer control and five different cameras, allows a variety of combustion experiments to be performed safely aboard the station.
Time lapse of CIR rack rotate and R&R
2014-07-21
ISS040-E-072228 (21 July 2014) --- In the International Space Station’s Destiny laboratory, NASA astronaut Reid Wiseman, Expedition 40 flight engineer, sets up the Combustion Integrated Rack (CIR) for more ground-commanded tests. This facility, which includes an optics bench, combustion chamber, fuel and oxidizer control and five different cameras, allows a variety of combustion experiments to be performed safely aboard the station.
Blood-Banking Techniques for Plateletpheresis in Swine
2014-05-01
automatically calculates the blood volume for that patient according to an internal formula . However, to circumvent the human-based algorithm, for a 60-kg...blood volume (µL) in the percentage recovery formula given earlier. The maximal recovery percent- age was calculated by setting the 3-min results to 100...Control Resuscitation Department, the Veterinary Support Department, and the Laboratory Support Department for their expert technical assistance
Lloyd, C H; Yearn, J A; Cowper, G A; Blavier, J; Vanderdonckt, M
2004-07-01
The setting expansion is an important property for a phosphate-bonded investment material. This research was undertaken to investigate a test that might be suitable for its measurement when used in a Standard. In the 'Casting-Ring Test', the investment sample is contained in a steel ring and expands to displace a precisely positioned pin. Variables with the potential to alter routine reproduction of the value were investigated. The vacuum-mixer model is a production laboratory variable that must not be ignored and for this reason, experiments were repeated using a different vacuum-mixer located at a second test site. Restraint by the rigid ring material increased expansion, while force on the pin reduced it. Expansion was specific to the lining selected. Increased environmental temperature decreased the final value. Expansion was still taking place at a time at which its value might be measured. However, when these factors are set, the reproducibility of values for setting expansion was good at both test sites (coefficient of variation 14%, at most). The results revealed that with the control that is available reliable routine measurement is possible in a Standard test. The inter-laboratory variable, vacuum-mixer model, produced significant differences and it should be the subject of further investigation.
NASA Astrophysics Data System (ADS)
Štaffenová, Daniela; Rybárik, Ján; Jakubčík, Miroslav
2017-06-01
The aim of experimental research in the area of exterior walls and windows suitable for wooden buildings was to build special pavilion laboratories. These laboratories are ideally isolated from the surrounding environment, airtight and controlled by the constant internal climate. The principle of experimental research is measuring and recording of required physical parameters (e.g. temperature or relative humidity). This is done in layers of experimental fragment sections in the direction from exterior to interior, as well as in critical places by stable interior and real exterior climatic conditions. The outputs are evaluations of experimental structures behaviour during the specified time period, possibly during the whole year by stable interior and real exterior boundary conditions. The main aim of this experimental research is processing of long-term measurements of experimental structures and the subsequent analysis. The next part of the research consists of collecting measurements obtained with assistance of the experimental detached weather station, analysis, evaluation for later setting up of reference data set for the research locality, from the point of view of its comparison to the data sets from Slovak Hydrometeorological Institute (SHMU) and to localities with similar climate conditions. Later on, the data sets could lead to recommendations for design of wooden buildings.
Evangelopoulos, Angelos A; Dalamaga, Maria; Panoutsopoulos, Konstantinos; Dima, Kleanthi
2013-01-01
In the early 80s, the word automation was used in the clinical laboratory setting referring only to analyzers. But in late 80s and afterwards, automation found its way into all aspects of the diagnostic process, embracing not only the analytical but also the pre- and post-analytical phase. While laboratories in the eastern world, mainly Japan, paved the way for laboratory automation, US and European laboratories soon realized the benefits and were quick to follow. Clearly, automation and robotics will be a key survival tool in a very competitive and cost-concious healthcare market. What sets automation technology apart from so many other efficiency solutions are the dramatic savings that it brings to the clinical laboratory. Further standardization will assure the success of this revolutionary new technology. One of the main difficulties laboratory managers and personnel must deal with when studying solutions to reengineer a laboratory is familiarizing themselves with the multidisciplinary and technical terminology of this new and exciting field. The present review/glossary aims at giving an overview of the most frequently used terms within the scope of laboratory automation and to put laboratory automation on a sounder linguistic basis.
Fact sheet to help academic laboratories decide whether to opt into the alternate set of hazardous waste requirements for eligible academic laboratories found in RCRA subpart K, how to plan for the transition to subpart K, and what first steps to take.
Manufacturing information system
NASA Astrophysics Data System (ADS)
Allen, D. K.; Smith, P. R.; Smart, M. J.
1983-12-01
The size and cost of manufacturing equipment has made it extremely difficult to perform realistic modeling and simulation of the manufacturing process in university research laboratories. Likewise the size and cost factors, coupled with many uncontrolled variables of the production situation has even made it difficult to perform adequate manufacturing research in the industrial setting. Only the largest companies can afford manufacturing research laboratories; research results are often held proprietary and seldom find their way into the university classroom to aid in education and training of new manufacturing engineers. It is the purpose for this research to continue the development of miniature prototype equipment suitable for use in an integrated CAD/CAM Laboratory. The equipment being developed is capable of actually performing production operations (e.g. drilling, milling, turning, punching, etc.) on metallic and non-metallic workpieces. The integrated CAD/CAM Mini-Lab is integrating high resolution, computer graphics, parametric design, parametric N/C parts programmings, CNC machine control, automated storage and retrieval, with robotics materials handling. The availability of miniature CAD/CAM laboratory equipment will provide the basis for intensive laboratory research on manufacturing information systems.
St. Hilaire, Melissa A.; Sullivan, Jason P.; Anderson, Clare; Cohen, Daniel A.; Barger, Laura K.; Lockley, Steven W.; Klerman, Elizabeth B.
2012-01-01
There is currently no “gold standard” marker of cognitive performance impairment resulting from sleep loss. We utilized pattern recognition algorithms to determine which features of data collected under controlled laboratory conditions could most reliably identify cognitive performance impairment in response to sleep loss using data from only one testing session, such as would occur in the “real world” or field conditions. A training set for testing the pattern recognition algorithms was developed using objective Psychomotor Vigilance Task (PVT) and subjective Karolinska Sleepiness Scale (KSS) data collected from laboratory studies during which subjects were sleep deprived for 26 – 52 hours. The algorithm was then tested in data from both laboratory and field experiments. The pattern recognition algorithm was able to identify performance impairment with a single testing session in individuals studied under laboratory conditions using PVT, KSS, length of time awake and time of day information with sensitivity and specificity as high as 82%. When this algorithm was tested on data collected under real-world conditions from individuals whose data were not in the training set, accuracy of predictions for individuals categorized with low performance impairment were as high as 98%. Predictions for medium and severe performance impairment were less accurate. We conclude that pattern recognition algorithms may be a promising method for identifying performance impairment in individuals using only current information about the individual’s behavior. Single testing features (e.g., number of PVT lapses) with high correlation with performance impairment in the laboratory setting may not be the best indicators of performance impairment under real-world conditions. Pattern recognition algorithms should be further tested for their ability to be used in conjunction with other assessments of sleepiness in real-world conditions to quantify performance impairment in response to sleep loss. PMID:22959616
ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.
Flatland, Bente; Freeman, Kathleen P; Vap, Linda M; Harr, Kendal E
2013-12-01
Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting. © 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crandall, R.S.; Nelson, B.P.; Moskowitz, P.D.
1992-07-01
To ensure the continued safety of SERI`s employees, the community, and the environment, NREL commissioned an internal audit of its photovoltaic operations that used hazardous production materials (HPMS). As a result of this audit, NREL management voluntarily suspended all operations using toxic and/or pyrophoric gases. This suspension affected seven laboratories and ten individual deposition systems. These activities are located in Building 16, which has a permitted occupancy of Group B, Division 2 (B-2). NREL management decided to do the following. (1) Exclude from this SAR all operations which conformed, or could easily be made to conform, to B-2 Occupancy requirements.more » (2) Include in this SAR all operations that could be made to conform to B-2 Occupancy requirements with special administrative and engineering controls. (3) Move all operations that could not practically be made to conform to B-2 occupancy requirements to alternate locations. In addition to the layered set of administrative and engineering controls set forth in this SAR, a semiquantitative risk analysis was performed on 30 various accident scenarios. Twelve presented only routine risks, while 18 presented low risks. Considering the demonstrated safe operating history of NREL in general and these systems specifically, the nature of the risks identified, and the layered set of administrative and engineering controls, it is clear that this facility falls within the DOE Low Hazard Class. Each operation can restart only after it has passed an Operational Readiness Review, comparing it to the requirements of this SAR, while subsequent safety inspections will ensure future compliance. This document contains the appendices to the NREL safety analysis report.« less
Wu, Alan H B; Smith, Andrew; McComb, Robert; Bowers, George N; Makowski, Gregory S; McKay, Charles A; Vena, Jason; McDonagh, John; Hopfer, Sidney; Sena, Salvatore F; Malkus, Herbert; Forte, Elaine; Kelly, Katherine
2008-02-01
Hospital laboratories currently lack the capacity to provide emergency determination of cholinesterase activity. We have developed a hospital-based 3-tiered system to test plasma for butyrylcholinesterase (BChE) activity and whole blood for red cell acetylcholinesterase (AChE) activity using available technology and personnel. Interagency communications, toxidrome definition, and patient triage will be coordinated by the Connecticut Department of Public Health and the Poison Control Center. Initial BChE data documents good precision between institutions (coefficient of variation < 8%). Laboratory testing of plasma or blood for cholinesterase activity is important in the management of nerve agent exposure and in ruling out disease in those with non-specific symptoms in the setting of a terrorist attack or accidental exposure. Rapid availability of strong hospital-based analytic support in a smoothly functioning network of clinical, public health, and laboratory services will facilitate overall regional response to chemical terrorism or large scale HazMat events.
Spira, Thomas; Lindegren, Mary Lou; Ferris, Robert; Habiyambere, Vincent; Ellerbrock, Tedd
2009-06-01
The expansion of HIV/AIDS care and treatment in resource-constrained countries, especially in sub-Saharan Africa, has generally developed in a top-down manner. Further expansion will involve primary health centers where human and other resources are limited. This article describes the World Health Organization/President's Emergency Plan for AIDS Relief collaboration formed to help scale up HIV services in primary health centers in high-prevalence, resource-constrained settings. It reviews the contents of the Operations Manual developed, with emphasis on the Laboratory Services chapter, which discusses essential laboratory services, both at the center and the district hospital level, laboratory safety, laboratory testing, specimen transport, how to set up a laboratory, human resources, equipment maintenance, training materials, and references. The chapter provides specific information on essential tests and generic job aids for them. It also includes annexes containing a list of laboratory supplies for the health center and sample forms.
NETL Extreme Drilling Laboratory Studies High Pressure High Temperature Drilling Phenomena
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyons, K.D.; Honeygan, S.; Moroz, T.H.
2008-12-01
The U.S. Department of Energy's National Energy Technology Laboratory (NETL) established the Extreme Drilling Laboratory to engineer effective and efficient drilling technologies viable at depths greater than 20,000 ft. This paper details the challenges of ultradeep drilling, documents reports of decreased drilling rates as a result of increasing fluid pressure and temperature, and describes NETL's research and development activities. NETL is invested in laboratory-scale physical simulation. Its physical simulator will have capability of circulating drilling fluids at 30,000 psi and 480°F around a single drill cutter. This simulator is not yet operational; therefore, the results will be limited to themore » identification of leading hypotheses of drilling phenomena and NETL's test plans to validate or refute such theories. Of particular interest to the Extreme Drilling Laboratory's studies are the combinatorial effects of drilling fluid pressure, drilling fluid properties, rock properties, pore pressure, and drilling parameters, such as cutter rotational speed, weight on bit, and hydraulics associated with drilling fluid introduction to the rock-cutter interface. A detailed discussion of how each variable is controlled in a laboratory setting will be part of the conference paper and presentation.« less
NASA Astrophysics Data System (ADS)
Pavlov, S. S.; Dmitriev, A. Yu.; Chepurchenko, I. A.; Frontasyeva, M. V.
2014-11-01
The automation system for measurement of induced activity of gamma-ray spectra for multi-element high volume neutron activation analysis (NAA) was designed, developed and implemented at the reactor IBR-2 at the Frank Laboratory of Neutron Physics. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis of linear positioning module M202A by DriveSet company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database.
Respiratory Sinus Arrhythmia, Shyness, and Effortful Control in Preschool-Age Children
Sulik, Michael J.; Eisenberg, Nancy; Silva, Kassondra M.; Spinrad, Tracy L.; Kupfer, Anne
2015-01-01
Resting respiratory sinus arrhythmia (RSA) and shyness were examined as predictors of effortful control (EC) in a sample of 101 preschool-age children. Resting RSA was calculated from respiration and heart rate data collected during a neutral film; shyness was measured using parents’, preschool teachers’, and classroom observers’ reports; and EC was measured using four laboratory tasks in addition to questionnaire measures. Principal components analysis was used to create composite measures of EC and shyness. The relation between RSA and EC was moderated by shyness, such that RSA was positively related to EC only for children high in shyness. This interaction suggests that emotional reactivity affects the degree to which RSA can be considered a correlate of EC. This study also draws attention to the need to consider the measurement context when assessing resting psychophysiology measures; shy individuals may not exhibit true baseline RSA responding in an unfamiliar laboratory setting. PMID:23127725
Near Field Observations of Seismicity in Volcanic Environments: A Read-Made Field Laboratory
NASA Astrophysics Data System (ADS)
Bean, C. J.; Thun, J.; Eibl, E. P. S.; Benson, P. M.; Rowley, P.; Lokmer, I.; Cauchie, L.
2017-12-01
Volcanic environments experience periods of rapid stress fluctuations and consequent seismicity. This volcano seismicity is diverse in character, spanning the range from discrete high frequency events through low-frequency earthquakes and tremor. The inter-relationships between these events appear to be controlled by edifice rheology, stress state and the presence of fluids (which help modulate the stress field). In general volcanoes are accessible to instrumentation, allowing near-field access to the seismicity at play. Here we present results from a range of field, numerical and laboratory experiments that demonstrate the controls that rheology and strain rate play on seismicity type. In particular we demonstrate the role played by internal friction angles on the initiation and evolution of seismicity, in dry weak-compliant volcanic materials. Furthermore we show the importance of near field observation in constraining details of the seismic source, in a meso-scale field setting.
Visible light reduces C. elegans longevity.
De Magalhaes Filho, C Daniel; Henriquez, Brian; Seah, Nicole E; Evans, Ronald M; Lapierre, Louis R; Dillin, Andrew
2018-03-02
The transparent nematode Caenorhabditis elegans can sense UV and blue-violet light to alter behavior. Because high-dose UV and blue-violet light are not a common feature outside of the laboratory setting, we asked what role, if any, could low-intensity visible light play in C. elegans physiology and longevity. Here, we show that C. elegans lifespan is inversely correlated to the time worms were exposed to visible light. While circadian control, lite-1 and tax-2 do not contribute to the lifespan reduction, we demonstrate that visible light creates photooxidative stress along with a general unfolded-protein response that decreases the lifespan. Finally, we find that long-lived mutants are more resistant to light stress, as well as wild-type worms supplemented pharmacologically with antioxidants. This study reveals that transparent nematodes are sensitive to visible light radiation and highlights the need to standardize methods for controlling the unrecognized biased effect of light during lifespan studies in laboratory conditions.
Mtisi, Takudzwa J; Maponga, Charles; Monera-Penduka, Tsitsi G; Mudzviti, Tinashe; Chagwena, Dexter; Makita-Chingombe, Faithful; DiFranchesco, Robin; Morse, Gene D
2018-01-01
A growing number of drug development studies that include pharmacokinetic evaluations are conducted in regions lacking a specialised pharmacology laboratory. This necessitated the development of an International Pharmacology Specialty Laboratory (IPSL) in Zimbabwe. The aim of this article is to describe the development of an IPSL in Zimbabwe. The IPSL was developed collaboratively by the University of Zimbabwe and the University at Buffalo Center for Integrated Global Biomedical Sciences. Key stages included infrastructure development, establishment of quality management systems and collaborative mentorship in clinical pharmacology study design and chromatographic assay development and validation. Two high performance liquid chromatography instruments were donated by an instrument manufacturer and a contract research organisation. Laboratory space was acquired through association with the Zimbabwe national drug regulatory authority. Operational policies, standard operating procedures and a document control system were established. Scientists and technicians were trained in aspects relevant to IPSL operations. A high-performance liquid chromatography method for nevirapine was developed with the guidance of the Clinical Pharmacology Quality Assurance programme and approved by the assay method review programme. The University of Zimbabwe IPSL is engaged with the United States National Institute of Allergy and Infectious Diseases Division of AIDS research networks and is poised to begin drug assays and pharmacokinetic analyses. An IPSL has been successfully established in a resource-limited setting through the efforts of an external partnership providing technical guidance and motivated internal faculty and staff. Strategic partnerships were beneficial in navigating challenges leading to laboratory development and training new investigators. The IPSL is now engaged in clinical pharmacology research.
Measuring preschool learning engagement in the laboratory.
Halliday, Simone E; Calkins, Susan D; Leerkes, Esther M
2018-03-01
Learning engagement is a critical factor for academic achievement and successful school transitioning. However, current methods of assessing learning engagement in young children are limited to teacher report or classroom observation, which may limit the types of research questions one could assess about this construct. The current study investigated the validity of a novel assessment designed to measure behavioral learning engagement among young children in a standardized laboratory setting and examined how learning engagement in the laboratory relates to future classroom adjustment. Preschool-aged children (N = 278) participated in a learning-based Tangrams task and Story sequencing task and were observed based on seven behavioral indicators of engagement. Confirmatory factor analysis supported the construct validity for a behavioral engagement factor composed of six of the original behavioral indicators: attention to instructions, on-task behavior, enthusiasm/energy, persistence, monitoring progress/strategy use, and negative affect. Concurrent validity for this behavioral engagement factor was established through its associations with parent-reported mastery motivation and pre-academic skills in math and literacy measured in the laboratory, and predictive validity was demonstrated through its associations with teacher-reported classroom learning behaviors and performance in math and reading in kindergarten. These associations were found when behavioral engagement was observed during both the nonverbal task and the verbal story sequencing tasks and persisted even after controlling for child minority status, gender, and maternal education. Learning engagement in preschool appears to be successfully measurable in a laboratory setting. This finding has implications for future research on the mechanisms that support successful academic development. Copyright © 2017 Elsevier Inc. All rights reserved.
Comparisons of Ground Truth and Remote Spectral Measurements of the FORMOSAT and ANDE Spacecrafts
NASA Technical Reports Server (NTRS)
JorgensenAbercromby, Kira; Hamada, Kris; Okada, Jennifer; Guyote, Michael; Barker, Edwin
2006-01-01
Determining the material type of objects in space is conducted using laboratory spectral reflectance measurements from common spacecraft materials and comparing the results to remote spectra. This past year, two different ground-truth studies commenced. The first, FORMOSAT III, is a Taiwanese set of six satellites to be launched in March 2006. The second is ANDE (Atmospheric Neutral Density Experiment), a Naval Research Laboratory set of two satellites set to launch from the Space Shuttle in November 2006. Laboratory spectra were obtained of the spacecraft and a model of the anticipated spectra response was created for each set of satellites. The model takes into account phase angle and orientation of the spacecraft relative to the observer. Once launched, the spacecraft are observed once a month to determine the space aging effects of materials as deduced from the remote spectra. Preliminary results will be shown of the FORMOSAT III comparison with laboratory data and remote data while results from only the laboratory data will be shown for the ANDE spacecraft.
Stoops, William W.; Rush, Craig R.
2016-01-01
Cocaine use disorder is a persistent public health problem for which no widely effective medications exist. Self-administration procedures, which have shown good predictive validity in estimating the abuse potential of drugs, have been used in rodent, nonhuman primate, and human laboratory studies to screen putative medications. This review assessed the effectiveness of the medications development process regarding pharmacotherapies for cocaine use disorder. The primary objective was to determine whether data from animal and human laboratory self-administration studies predicted the results of clinical trials. In addition, the concordance between laboratory studies in animals and humans was assessed. More than 100 blinded, randomized, fully placebo-controlled studies of putative medications for cocaine use disorder were identified. Of the 64 drugs tested in these trials, only 10 had been examined in both human and well-controlled animal laboratory studies. Within all three stages, few studies had been conducted for each drug and when multiple studies had been conducted conclusions were sometimes contradictory. Overall, however, there was good concordance between animal and human laboratory results when the former assessed chronic drug treatment. Although only seven of the ten reviewed drugs showed fully concordant results across all three types of studies reviewed, the analysis revealed several subject-related, procedural, and environmental factors that differ between the laboratory and clinical trial settings that help explain the disagreement for other drugs. The review closes with several recommendations to enhance translation and communication across stages of the medications development process that will ultimately speed the progress toward effective pharmacotherapeutic strategies for cocaine use disorder. PMID:27255266
Lee, Kang-Hoon; Lim, Debora; Chiu, Sophia; Greenhalgh, David; Cho, Kiho
2016-04-01
Laboratory strains of mice, both conventional and genetically engineered, have been introduced as critical components of a broad range of studies investigating normal and disease biology. Currently, the genetic identity of laboratory mice is primarily confirmed by surveying polymorphisms in selected sets of "conventional" genes and/or microsatellites in the absence of a single completely sequenced mouse genome. First, we examined variations in the genomic landscapes of transposable repetitive elements, named the TREome, in conventional and genetically engineered mouse strains using murine leukemia virus-type endogenous retroviruses (MLV-ERVs) as a probe. A survey of the genomes from 56 conventional strains revealed strain-specific TREome landscapes, and certain families (e.g., C57BL) of strains were discernible with defined patterns. Interestingly, the TREome landscapes of C3H/HeJ (toll-like receptor-4 [TLR4] mutant) inbred mice were different from its control C3H/HeOuJ (TLR4 wild-type) strain. In addition, a CD14 knock-out strain had a distinct TREome landscape compared to its control/backcross C57BL/6J strain. Second, an examination of superantigen (SAg, a "TREome gene") coding sequences of mouse mammary tumor virus-type ERVs in the genomes of the 46 conventional strains revealed a high diversity, suggesting a potential role of SAgs in strain-specific immune phenotypes. The findings from this study indicate that unexplored and intricate genomic variations exist in laboratory mouse strains, both conventional and genetically engineered. The TREome-based high-resolution genetics surveillance system for laboratory mice would contribute to efficient study design with quality control and accurate data interpretation. This genetics system can be easily adapted to other species ranging from plants to humans. Copyright © 2016 Elsevier Inc. All rights reserved.
Building laboratory capacity to support HIV care in Nigeria: Harvard/APIN PEPFAR, 2004-2012.
Hamel, Donald J; Sankalé, Jean-Louis; Samuels, Jay Osi; Sarr, Abdoulaye D; Chaplin, Beth; Ofuche, Eke; Meloni, Seema T; Okonkwo, Prosper; Kanki, Phyllis J
From 2004-2012, the Harvard/AIDS Prevention Initiative in Nigeria, funded through the US President's Emergency Plan for AIDS Relief programme, scaled up HIV care and treatment services in Nigeria. We describe the methodologies and collaborative processes developed to improve laboratory capacity significantly in a resource-limited setting. These methods were implemented at 35 clinic and laboratory locations. Systems were established and modified to optimise numerous laboratory processes. These included strategies for clinic selection and management, equipment and reagent procurement, supply chains, laboratory renovations, equipment maintenance, electronic data management, quality development programmes and trainings. Over the eight-year programme, laboratories supported 160 000 patients receiving HIV care in Nigeria, delivering over 2.5 million test results, including regular viral load quantitation. External quality assurance systems were established for CD4+ cell count enumeration, blood chemistries and viral load monitoring. Laboratory equipment platforms were improved and standardised and use of point-of-care analysers was expanded. Laboratory training workshops supported laboratories toward increasing staff skills and improving overall quality. Participation in a World Health Organisation-led African laboratory quality improvement system resulted in significant gains in quality measures at five laboratories. Targeted implementation of laboratory development processes, during simultaneous scale-up of HIV treatment programmes in a resource-limited setting, can elicit meaningful gains in laboratory quality and capacity. Systems to improve the physical laboratory environment, develop laboratory staff, create improvements to reduce costs and increase quality are available for future health and laboratory strengthening programmes. We hope that the strategies employed may inform and encourage the development of other laboratories in resource-limited settings.
Britton, Sumudu; Cheng, Qin; McCarthy, James S
2016-02-16
As malaria transmission continues to decrease, an increasing number of countries will enter pre-elimination and elimination. To interrupt transmission, changes in control strategies are likely to require more accurate identification of all carriers of Plasmodium parasites, both symptomatic and asymptomatic, using diagnostic tools that are highly sensitive, high throughput and with fast turnaround times preferably performed in local health service settings. Currently available immunochromatographic lateral flow rapid diagnostic tests and field microscopy are unlikely to consistently detect infections at parasite densities less than 100 parasites/µL making them insufficiently sensitive for detecting all carriers. Molecular diagnostic platforms, such as PCR and LAMP, are currently available in reference laboratories, but at a cost both financially and in turnaround time. This review describes the recent progress in developing molecular diagnostic tools in terms of their capacity for high throughput and potential for performance in non-reference laboratories for malaria elimination.
Critical issues using brain-computer interfaces for augmentative and alternative communication.
Hill, Katya; Kovacs, Thomas; Shin, Sangeun
2015-03-01
Brain-computer interfaces (BCIs) may potentially be of significant practical value to patients in advanced stages of amyotrophic lateral sclerosis and locked-in syndrome for whom conventional augmentative and alternative communication (AAC) systems, which require some measure of consistent voluntary muscle control, are not satisfactory options. However, BCIs have primarily been used for communication in laboratory research settings. This article discusses 4 critical issues that should be addressed as BCIs are translated out of laboratory settings to become fully functional BCI/AAC systems that may be implemented clinically. These issues include (1) identification of primary, secondary, and tertiary system features; (2) integrating BCI/AAC systems in the World Health Organization's International Classification of Functioning, Disability and Health framework; (3) implementing language-based assessment and intervention; and (4) performance measurement. A clinical demonstration project is presented as an example of research beginning to address these critical issues. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Survival of influenza virus on hands and fomites in community and laboratory settings.
Mukherjee, Dhritiman V; Cohen, Bevin; Bovino, Mary Ellen; Desai, Shailesh; Whittier, Susan; Larson, Elaine L
2012-09-01
Transmission dynamics modeling provides a practical method for virtual evaluation of the impact of public health interventions in response to prospective influenza pandemics and also may help determine the relative contribution of different modes of transmission to overall infection rates. Accurate estimates of longevity for all forms of viral particles are needed for such models to be useful. We conducted a time course study to determine the viability and longevity of H1N1 virus on naturally contaminated hands and household surfaces of 20 individuals with laboratory-confirmed infection. Participants coughed or sneezed into their hands, which were sampled immediately and again after 5, 10, and 30 minutes. Samples also were obtained from household surfaces handled by the participants immediately after coughing/sneezing. Clinically obtained H1N1 isolates were used to assess the viability and longevity of the virus on various artificially inoculated common household surfaces and human hands in a controlled laboratory setting. Viral detection was achieved by culture and real-time reverse-transcriptase polymerase chain reaction. The results suggest that H1N1 does not survive long on naturally contaminated skin and fomites, and that secretions deposited on hands by coughing or sneezing have a concentration of <2.15 × 10 to 2.94 × 10 TCID(50)/mL. These data can be used to estimate the relative contribution of direct and indirect contact transmission on overall infection rates. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Directing change: a contemporary administrative challenge.
Hardwick, D F; Hardwick, W G; diZerega, A
1997-04-01
Although most individuals who head clinical laboratories are still named Director of Laboratories, their training for this has focused principally on management training in addition to their postgraduate medical education. The implicit assumption seems to be either that direction and management are synonymous or that management is the most important aspect of laboratory administration. Common usage, albeit imprecise, fosters both of these paradigms. The proposition of this article is that directing and managing are two discrete activities of sufficiently different orientation as to require different training, attitudes, and values. Management as a generic phenomenon was codified early in this century through the works of F.W. Taylor (1), whose concepts of scientific management were embraced with zeal during World War I and were also an important conceptual basis for the managed economy of the Soviet Union as proposed by Lenin. Gradually, management with concern for efficiency and hierarchic control structures has diffused throughout social as well as business systems. Many will remember the introduction of the corporate governance system into hospitals beginning in the 1930s and its spread throughout the medical system until at present administrators of hospitals, for example, are called CEOs or presidents. Management, as narrowly defined and as traditionally practiced, is based on control of a system by adherence to prescribed standards for uniform production, to particularized timelines for delivery of product or service precisely when needed, and to predetermined budgets for efficiency and predictability. All of these are laudable and essential to the internal administration of any system. They also require a specific set of values and a set of behaviors that center on adaptability and compliance.
Recent advances in tuberculosis diagnostics in resource-limited settings.
Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi
2018-04-19
Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.
Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L
2017-06-01
Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
21 CFR 606.140 - Laboratory controls.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...
21 CFR 606.140 - Laboratory controls.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...
21 CFR 606.140 - Laboratory controls.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...
21 CFR 606.140 - Laboratory controls.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Laboratory controls. 606.140 Section 606.140 Food... CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Laboratory Controls § 606.140 Laboratory controls. Laboratory control procedures shall include: (a) The establishment of scientifically...
NASA Technical Reports Server (NTRS)
Ruiz, Ian B.; Burke, Gary R.; Lung, Gerald; Whitaker, William D.; Nowicki, Robert M.
2004-01-01
The Jet Propulsion Laboratory (JPL) has developed a command interface chip-set that primarily consists of two mixed-signal ASICs'; the Command Interface ASIC (CIA) and Analog Interface ASIC (AIA). The Open-systems architecture employed during the design of this chip-set enables its use as both an intelligent gateway between the system's flight computer and the control, actuation, and activation of the spacecraft's loads, valves, and pyrotechnics respectfully as well as the regulator of the spacecraft power bus. Furthermore, the architecture is highly adaptable and employed fault-tolerant design methods enabling a host of other mission uses including reliable remote data collection. The objective of this design is to both provide a needed flight component that meets the stringent environmental requirements of current deep space missions and to add a new element to a growing library that can be used as a standard building block for future missions to the outer planets.
[Compatibility of different quality control systems].
Invernizzi, Enrico
2002-01-01
Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.
Smith, Jeffrey D.; MacDougall, Colin C.; Johnstone, Jennie; Copes, Ray A.; Schwartz, Brian; Garber, Gary E.
2016-01-01
Background: Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. Methods: We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case–control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. Results: We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case–control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64–1.24; cohort study: OR 0.43, 95% CI 0.03–6.41; case–control studies: OR 0.91, 95% CI 0.25–3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19–1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57–1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Interpretation: Although N95 respirators appeared to have a protective advantage over surgical masks in laboratory settings, our meta-analysis showed that there were insufficient data to determine definitively whether N95 respirators are superior to surgical masks in protecting health care workers against transmissible acute respiratory infections in clinical settings. PMID:26952529
Smith, Jeffrey D; MacDougall, Colin C; Johnstone, Jennie; Copes, Ray A; Schwartz, Brian; Garber, Gary E
2016-05-17
Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case-control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case-control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64-1.24; cohort study: OR 0.43, 95% CI 0.03-6.41; case-control studies: OR 0.91, 95% CI 0.25-3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19-1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57-1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Although N95 respirators appeared to have a protective advantage over surgical masks in laboratory settings, our meta-analysis showed that there were insufficient data to determine definitively whether N95 respirators are superior to surgical masks in protecting health care workers against transmissible acute respiratory infections in clinical settings. © 2016 Canadian Medical Association or its licensors.
Fine-grained policy control in U.S. Army Research Laboratory (ARL) multimodal signatures database
NASA Astrophysics Data System (ADS)
Bennett, Kelly; Grueneberg, Keith; Wood, David; Calo, Seraphin
2014-06-01
The U.S. Army Research Laboratory (ARL) Multimodal Signatures Database (MMSDB) consists of a number of colocated relational databases representing a collection of data from various sensors. Role-based access to this data is granted to external organizations such as DoD contractors and other government agencies through a client Web portal. In the current MMSDB system, access control is only at the database and firewall level. In order to offer finer grained security, changes to existing user profile schemas and authentication mechanisms are usually needed. In this paper, we describe a software middleware architecture and implementation that allows fine-grained access control to the MMSDB at a dataset, table, and row level. Result sets from MMSDB queries issued in the client portal are filtered with the use of a policy enforcement proxy, with minimal changes to the existing client software and database. Before resulting data is returned to the client, policies are evaluated to determine if the user or role is authorized to access the data. Policies can be authored to filter data at the row, table or column level of a result set. The system uses various technologies developed in the International Technology Alliance in Network and Information Science (ITA) for policy-controlled information sharing and dissemination1. Use of the Policy Management Library provides a mechanism for the management and evaluation of policies to support finer grained access to the data in the MMSDB system. The GaianDB is a policy-enabled, federated database that acts as a proxy between the client application and the MMSDB system.
Defining Polio: Closing the Gap in Global Surveillance.
Tajaldin, Bachir; Almilaji, Khaled; Langton, Paul; Sparrow, Annie
2015-01-01
By late 2012 the Global Polio Eradication Initiative (GPEI) had nearly eradicated this ancient infectious disease. Successful surveillance programs for acute flaccid paralysis however rely on broad governmental support for implementation. With the onset of conflict, public health breakdown has contributed to the resurgence of polio in a number of regions. The current laboratory based case definition may be a contributory factor in these regions. We sought to compare case definition rates using strict laboratory based criteria to rates obtained using the clinical criteria in modern day Syria. We also sought to examine this distribution of cases by sub-region. We examined the World Health Organization (WHO) reported figures for Syria from 2013-2014 using laboratory based criteria. We compared these with cases obtained when clinical criteria were applied. In addition we sought data from the opposition controlled Assistance Coordination Unit which operates in non-Government controlled areas where WHO data maybe incomplete. Cases were carefully examined for potential overlap to avoid double reporting. Whilst the WHO data clearly confirmed the polio outbreak in Syria, it did so with considerable delay and with under reporting of cases, particularly from non-government controlled areas. In addition, laboratory based case definition led to a substantial underestimate of polio (36 cases) compared with those found with the clinically compatible definition (an additional 46 cases). Rates of adequate diagnostic specimens from suspected cases are well below target, no doubt reflecting the effect of conflict in these areas. We have identified a gap in the surveillance of polio, a global threat. The current laboratory based definition, in the setting of conflict and insecurity, leads to under diagnosis of polio with potential delays and inadequacies in coordinating effective responses to contain outbreaks and eradicate polio. Breakdown in public health measures as a contributing factor is likely to result in a resurgence of previously controlled infectious diseases. The clinical definition should be reinstituted to supplement the lab-based definition. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Considering the context: social factors in responses to drugs in humans.
de Wit, Harriet; Sayette, Michael
2018-04-01
Drugs are typically used in social settings. Here, we consider two factors that may contribute to this observation: (i) the presence of other people may enhance the positive mood effects of a drug, and conversely, (ii) drugs may enhance the value of social stimuli. We review evidence from controlled laboratory studies with human volunteers, which investigated either of these interactions between social factors and responses to drugs. We examine the bidirectional effects of social stimuli and single doses of alcohol, stimulants, opioids, and cannabis. All four classes of drugs interact with social contexts, but the nature of these interactions varies across drugs, and depends on whether the context is positive or negative. Alcohol and stimulant drugs enhance the attractiveness of social stimuli and the desire to socialize, and social contexts, in turn, enhance these drugs' effects. In contrast, opioids and cannabis have subtler effects on social interactions and their effects are less influenced by the presence of others. Overall, there is stronger evidence that drugs enhance positive social contexts than that they dampen the negativity of unpleasant social settings. Controlled research is needed to understand the interactions between drugs of abuse and social contexts, to model and understand the determinants of drug use outside the laboratory.
Grolla, A; Jones, S; Kobinger, G; Sprecher, A; Girard, G; Yao, M; Roth, C; Artsob, H; Feldmann, H; Strong, J E
2012-09-01
The mobile laboratory provides a safe, rapid and flexible platform to provide effective diagnosis of Ebola virus as well as additional differential diagnostic agents in remote settings of equatorial Africa. During the 2007 Democratic Republic of Congo outbreak of Ebola-Zaire, the mobile laboratory was set up in two different locations by two separate teams within a day of equipment arriving in each location. The first location was in Mweka where our laboratory took over the diagnostic laboratory space of the local hospital, whereas the second location, approximately 50 km south near Kampungu at the epicentre of the outbreak, required local labour to fabricate a tent structure as a suitable pre-existing structure was not available. In both settings, the laboratory was able to quickly set up, providing accurate and efficient molecular diagnostics (within 3 h of receiving samples) for 67 individuals, including four cases of Ebola, seven cases of Shigella and 13 cases of malaria. This rapid turn-around time provides an important role in the support of patient management and epidemiological surveillance. © 2012 Blackwell Verlag GmbH.
Building laboratory capacity to support HIV care in Nigeria: Harvard/APIN PEPFAR, 2004–2012
Hamel, Donald J.; Sankalé, Jean-Louis; Samuels, Jay Osi; Sarr, Abdoulaye D.; Chaplin, Beth; Ofuche, Eke; Meloni, Seema T.; Okonkwo, Prosper; Kanki, Phyllis J.
2015-01-01
Introduction From 2004–2012, the Harvard/AIDS Prevention Initiative in Nigeria, funded through the US President’s Emergency Plan for AIDS Relief programme, scaled up HIV care and treatment services in Nigeria. We describe the methodologies and collaborative processes developed to improve laboratory capacity significantly in a resource-limited setting. These methods were implemented at 35 clinic and laboratory locations. Methods Systems were established and modified to optimise numerous laboratory processes. These included strategies for clinic selection and management, equipment and reagent procurement, supply chains, laboratory renovations, equipment maintenance, electronic data management, quality development programmes and trainings. Results Over the eight-year programme, laboratories supported 160 000 patients receiving HIV care in Nigeria, delivering over 2.5 million test results, including regular viral load quantitation. External quality assurance systems were established for CD4+ cell count enumeration, blood chemistries and viral load monitoring. Laboratory equipment platforms were improved and standardised and use of point-of-care analysers was expanded. Laboratory training workshops supported laboratories toward increasing staff skills and improving overall quality. Participation in a World Health Organisation-led African laboratory quality improvement system resulted in significant gains in quality measures at five laboratories. Conclusions Targeted implementation of laboratory development processes, during simultaneous scale-up of HIV treatment programmes in a resource-limited setting, can elicit meaningful gains in laboratory quality and capacity. Systems to improve the physical laboratory environment, develop laboratory staff, create improvements to reduce costs and increase quality are available for future health and laboratory strengthening programmes. We hope that the strategies employed may inform and encourage the development of other laboratories in resource-limited settings. PMID:26900573
Road traffic noise-induced sleep disturbances: a comparison between laboratory and field settings
NASA Astrophysics Data System (ADS)
Skånberg, Annbritt
2004-10-01
Due to the ongoing discussion about the relevance of sleep studies performed in the laboratory, the aim of this study was to assess the effects of road traffic noise exposure on sleep in laboratory and in field settings. Eighteen healthy young subjects participated in the study. They were exposed to noise from road traffic in the laboratory and exposed to the same recorded traffic noise exposure in their own homes. Their sleep was evaluated with wrist actigraphs and questionnaires on sleep. No significant increase in effects of noise on sleep in the laboratory was found. The results indicate that laboratory experiments do not exaggerate effects of noise on sleep.
NASA Astrophysics Data System (ADS)
Michael Link, M. L.; Friedman, B.; Ortega, J. V.; Son, J.; Kim, J.; Park, G.; Park, T.; Kim, K.; Lee, T.; Farmer, D.
2016-12-01
Recent commercialization of the Oxidative Flow Reactor (OFR, occasionally described in the literature as a "Potential Aerosol Mass") has created the opportunity for many researchers to explore the mechanisms behind OH-driven aerosol formation on a wide range of oxidative timescales (hours to weeks) in both laboratory and field measurements. These experiments have been conducted in both laboratory and field settings, including simple (i.e. single component) and complex (multi-component) precursors. Standard practices for performing OFR experiments, and interpreting data from the measurements, are still being developed. Measurement of gas and particle phase chemistry, from oxidation products generated in the OFR, through laboratory studies on single precursors and the measurement of SOA from vehicle emissions on short atmospheric timescales represent two very different experiments in which careful experimental design is essential for exploring reaction mechanisms and SOA yields. Two parameters essential in experimental design are (1) the role of seed aerosol in controlling gas-particle partitioning and SOA yields, and (2) the accurate determination of OH exposure during any one experiment. We investigated the role of seed aerosol surface area in controlling the observed SOA yields and gas/particle composition from the OH-initiated oxidation of four monoterpenes using an aerosol chemical ionization time-of-flight mass spectrometer and scanning mobility particle sizer. While the OH exposure during laboratory experiments is simple to constrain, complex mixtures such as diesel exhaust have high estimated OH reactivity values, and thus require careful consideration. We developed methods for constraining OH radical exposure in the OFR during vehicle exhaust oxidation experiments. We observe changes in O/C ratios and highly functionalized species over the temperature gradient employed in the aerosol-CIMS measurement. We relate this observed, speciated chemistry to the volatility of the aerosol, and compare observed SOA yields to other OFR and smog chamber SOA generation methods. Additionally, estimates of OH radical exposure in the OFR during different vehicle experiments of varying fuel type and speed were observed to vary as determined from a high-NOx and variable humidity calibration set.
NASA Astrophysics Data System (ADS)
Endryansyah; Wanarti Rusimamto, Puput; Ridianto, Adam; Sugiarto, Hariyadi
2018-04-01
In the Department of Electrical Engineering FT Unesa, there are 3 majors: S1 Electrical Engineering Education, S1 Electrical Engineering, and D3 Electrical Engineering. Courses the Basic System Settings go to in the curriculum of the three programs. Team lecturer college of basic system settings seek learning innovation, focused on the development of trainer to student practicum at the laboratory of systems control. Trainer developed is a servo motor along with the lab module that contains a wide variety of theories about the servo motor and guide the practicum. This research type is development research using methods Research & development (R & D). In which the steps are applied in this study is as follows: pay attention to the potential and existing problems, gather information and study the literature, design the product, validate the design, revise the design, a limited trial. The results of the validation of learning device in the form of modules and trainer obtained as follows: score validation of learning device is 3,64; score validation lab module Servo Motor is 3,47; and questionnaire responses of students is 3,73. The result of the whole validation value is located in the interval >of 3.25 s/d 4 with the category of “Very Valid”, so it can be concluded that all instruments have a level of validity “Very Valid” and worthy of use for further learning.
Factors in the Selection of Surface Disinfectants for Use in a Laboratory Animal Setting
Campagna, Michael V; Faure-Kumar, Emmanuelle; Treger, Janet A; Cushman, Jesse D; Grogan, Tristan R; Kasahara, Noriyuki; Lawson, Gregory W
2016-01-01
Because surface disinfectants are an important means of pathogen control within laboratory animal facilities, these products must have an appropriate spectrum of antimicrobial activity. However, many other factors must also be considered, including effects on human health, environmental safety, and animal behavior. Aqueous solutions of sodium hypochlorite often are considered to be the ‘gold standard’ for surface disinfection, but these products can be corrosive, caustic, and aversive in odor. This study was designed to identify disinfectants that are as effective as hypochlorite solutions but more acceptable for use in a laboratory animal setting. An antiviral disinfectant-efficacy assay was developed by using viral vectors that expressed green fluorescence protein as surrogates for wild-type viruses of concern in laboratory animals. Efficacy testing revealed that most of the products were highly effective when used against viral vectors in suspension. However, when the disinfectants were challenged by buffering virus in protein or drying virus on nonporous surfaces, the hypochlorite and peroxymonosulfate products performed the best. Review of safety data sheets for the agents indicated that a peroxide-based product was considerably safer than the other products tested and that the pH of most products was not conducive to disposal down a drain. Behavioral testing of Swiss Webster, C57Bl/6, and BALB/c mice showed that the hypochlorite- and peroxide-based products were clearly aversive, given that the mice consistently avoided these products. All of these factors must be considered when choosing the appropriate disinfectant. PMID:27025810
Kaufman, Kenton R; Levine, James A; Brey, Robert H; McCrady, Shelly K; Padgett, Denny J; Joyner, Michael J
2008-07-01
To quantify the energy efficiency of locomotion and free-living physical activity energy expenditure of transfemoral amputees using a mechanical and microprocessor-controlled prosthetic knee. Repeated-measures design to evaluate comparative functional outcomes. Exercise physiology laboratory and community free-living environment. Subjects (N=15; 12 men, 3 women; age, 42+/-9 y; range, 26-57 y) with transfemoral amputation. Research participants were long-term users of a mechanical prosthesis (20+/-10 y as an amputee; range, 3-36 y). They were fitted with a microprocessor-controlled knee prosthesis and allowed to acclimate (mean time, 18+/-8 wk) before being retested. Objective measurements of energy efficiency and total daily energy expenditure were obtained. The Prosthetic Evaluation Questionnaire was used to gather subjective feedback from the participants. Subjects demonstrated significantly increased physical activity-related energy expenditure levels in the participant's free-living environment (P=.04) after wearing the microprocessor-controlled prosthetic knee joint. There was no significant difference in the energy efficiency of walking (P=.34). When using the microprocessor-controlled knee, the subjects expressed increased satisfaction in their daily lives (P=.02). People ambulating with a microprocessor-controlled knee significantly increased their physical activity during daily life, outside the laboratory setting, and expressed an increased quality of life.
Ballarini, E; Bauer, S; Eberhardt, C; Beyer, C
2012-06-01
Transverse dispersion represents an important mixing process for transport of contaminants in groundwater and constitutes an essential prerequisite for geochemical and biodegradation reactions. Within this context, this work describes the detailed numerical simulation of highly controlled laboratory experiments using uranine, bromide and oxygen depleted water as conservative tracers for the quantification of transverse mixing in porous media. Synthetic numerical experiments reproducing an existing laboratory experimental set-up of quasi two-dimensional flow through tank were performed to assess the applicability of an analytical solution of the 2D advection-dispersion equation for the estimation of transverse dispersivity as fitting parameter. The fitted dispersivities were compared to the "true" values introduced in the numerical simulations and the associated error could be precisely estimated. A sensitivity analysis was performed on the experimental set-up in order to evaluate the sensitivities of the measurements taken at the tank experiment on the individual hydraulic and transport parameters. From the results, an improved experimental set-up as well as a numerical evaluation procedure could be developed, which allow for a precise and reliable determination of dispersivities. The improved tank set-up was used for new laboratory experiments, performed at advective velocities of 4.9 m d(-1) and 10.5 m d(-1). Numerical evaluation of these experiments yielded a unique and reliable parameter set, which closely fits the measured tracer concentration data. For the porous medium with a grain size of 0.25-0.30 mm, the fitted longitudinal and transverse dispersivities were 3.49×10(-4) m and 1.48×10(-5) m, respectively. The procedures developed in this paper for the synthetic and rigorous design and evaluation of the experiments can be generalized and transferred to comparable applications. Copyright © 2012 Elsevier B.V. All rights reserved.
Analysis of near infrared spectra for age-grading of wild populations of Anopheles gambiae.
Krajacich, Benjamin J; Meyers, Jacob I; Alout, Haoues; Dabiré, Roch K; Dowell, Floyd E; Foy, Brian D
2017-11-07
Understanding the age-structure of mosquito populations, especially malaria vectors such as Anopheles gambiae, is important for assessing the risk of infectious mosquitoes, and how vector control interventions may impact this risk. The use of near-infrared spectroscopy (NIRS) for age-grading has been demonstrated previously on laboratory and semi-field mosquitoes, but to date has not been utilized on wild-caught mosquitoes whose age is externally validated via parity status or parasite infection stage. In this study, we developed regression and classification models using NIRS on datasets of wild An. gambiae (s.l.) reared from larvae collected from the field in Burkina Faso, and two laboratory strains. We compared the accuracy of these models for predicting the ages of wild-caught mosquitoes that had been scored for their parity status as well as for positivity for Plasmodium sporozoites. Regression models utilizing variable selection increased predictive accuracy over the more common full-spectrum partial least squares (PLS) approach for cross-validation of the datasets, validation, and independent test sets. Models produced from datasets that included the greatest range of mosquito samples (i.e. different sampling locations and times) had the highest predictive accuracy on independent testing sets, though overall accuracy on these samples was low. For classification, we found that intramodel accuracy ranged between 73.5-97.0% for grouping of mosquitoes into "early" and "late" age classes, with the highest prediction accuracy found in laboratory colonized mosquitoes. However, this accuracy was decreased on test sets, with the highest classification of an independent set of wild-caught larvae reared to set ages being 69.6%. Variation in NIRS data, likely from dietary, genetic, and other factors limits the accuracy of this technique with wild-caught mosquitoes. Alternative algorithms may help improve prediction accuracy, but care should be taken to either maximize variety in models or minimize confounders.
Hart, Kristen M.; Schofield, Pamela J.; Gregoire, Denise R.
2012-01-01
In a laboratory setting, we tested the ability of 24 non-native, wild-caught hatchling Burmese pythons (Python molurus bivittatus) collected in the Florida Everglades to survive when given water containing salt to drink. After a one-month acclimation period in the laboratory, we grouped snakes into three treatments, giving them access to water that was fresh (salinity of 0, control), brackish (salinity of 10), or full-strength sea water (salinity of 35). Hatchlings survived about one month at the highest marine salinity and about five months at the brackish-water salinity; no control animals perished during the experiment. These results are indicative of a "worst-case scenario", as in the laboratory we denied access to alternate fresh-water sources that may be accessible in the wild (e.g., through rainfall). Therefore, our results may underestimate the potential of hatchling pythons to persist in saline habitats in the wild. Because of the effect of different salinity regimes on survival, predictions of ultimate geographic expansion by non-native Burmese pythons that consider salt water as barriers to dispersal for pythons may warrant re-evaluation, especially under global climate change and associated sea-level-rise scenarios.
Hart, K.M.; Schofield, P.J.; Gregoire, D.R.
2012-01-01
In a laboratory setting, we tested the ability of 24 non-native, wild-caught hatchling Burmese pythons (Python molurus bivittatus) collected in the Florida Everglades to survive when given water containing salt to drink. After a one-month acclimation period in the laboratory, we grouped snakes into three treatments, giving them access to water that was fresh (salinity of 0, control), brackish (salinity of 10), or full-strength sea water (salinity of 35). Hatchlings survived about one month at the highest marine salinity and about five months at the brackish-water salinity; no control animals perished during the experiment. These results are indicative of a "worst-case scenario", as in the laboratory we denied access to alternate fresh-water sources that may be accessible in the wild (e.g., through rainfall). Therefore, our results may underestimate the potential of hatchling pythons to persist in saline habitats in the wild. Because of the effect of different salinity regimes on survival, predictions of ultimate geographic expansion by non-native Burmese pythons that consider salt water as barriers to dispersal for pythons may warrant re-evaluation, especially under global climate change and associated sea-level-rise scenarios. ?? 2011.
Willmott, Micky; Nicholson, Alexandra; Busse, Heide; MacArthur, Georgina J; Brookes, Sara; Campbell, Rona
2016-01-01
Objective To undertake a systematic review and meta-analysis to establish the effectiveness of handwashing in reducing absence and/or the spread of respiratory tract (RT) and/or gastrointestinal (GI) infection among school-aged children and/or staff in educational settings. Design Randomised-controlled trials (RCTs). Setting Schools and other settings with a formal educational component in any country. Patients Children aged 3–11 years, and/or staff working with them. Intervention Interventions with a hand hygiene component. Main outcome measures Incidence of RT or GI infections or symptoms related to such infections; absenteeism; laboratory results of RT and/or GI infections. Results Eighteen cluster RCTs were identified; 13 school-based, 5 in child day care facilities or preschools. Studies were heterogeneous and had significant quality issues including small numbers of clusters and participants and inadequate randomisation. Individual study results suggest interventions may reduce children's absence, RT infection incidence and symptoms, and laboratory confirmed influenza-like illness. Evidence of impact on GI infection or symptoms was equivocal. Conclusions Studies are generally not well executed or reported. Despite updating existing systematic reviews and identifying new studies, evidence of the effect of hand hygiene interventions on infection incidence in educational settings is mostly equivocal but they may decrease RT infection among children. These results update and add to knowledge about this crucial public health issue in key settings with a vulnerable population. More robust, well reported cluster RCTs which learn from existing studies, are required. PMID:26471110
Li, Jun; Guo, Qiang; Lin, Miaofeng; Jiang, Lu; Ye, Jingwen; Chen, Dasong; Li, Zhigang; Dai, Jianqing; Han, Shichou
2016-01-01
Solenopsis invicta Buren is one of the most important pests in China, and control measures are mainly based on the use of synthetic pesticides, which may be inadequate and unsustainable. Hence, there is a growing interest in developing biological control alternatives for managing S. invicta, such as the use of entomopathogenic fungi. To facilitate the commercialization of entomopathogenic fungi against S. invicta, 10 Beauveria bassiana isolates originating from different hosts were tested for virulence in laboratory bioassays, and the most pathogenic strain, ZGNKY-5, was tested in field studies using an improved pathogen delivery system. The cumulative mortality rate reached 93.40% at 1×108 mL-1 conidia after 504 h. The germination and invasion of the spores were observed under a scanning electron microscope, and several conidia adhered to the cuticle of S. invicta after 2 h. Furthermore, the germ tubes of the conidia oriented toward the cuticle after 48 h, and the mycelium colonized the entire body after 96 h. Based on the efficacy observed in the laboratory trials, further experiments were performed with ZGNKY-5 strain to evaluate its utility in an injection control technology against S. invicta in the field. We found that three dosage treatments of ZGNKY-5 strain (500 mL, 750 mL, and 1,000 mL per nest) had significant control effects. Our results show that this strain of Beauveria bassiana and our control method were effective against S. invicta in both laboratory and field settings. PMID:27341441
2015-08-01
faults are incorporated into the system in order to better understand the EMA reliability, and to aid in designing fault detection software for real...to a fixed angle repeatedly and accurately [16]. The motor in the EHA is used to drive a reversible pump tied to a hydraulic cylinder which moves...24] [25] [26]. These test stands are used for the prognostic testing of EMAS that have had mechanical or electrical faults injected into them. The
High temperature, harsh environment sensors for advanced power generation systems
NASA Astrophysics Data System (ADS)
Ohodnicki, P. R.; Credle, S.; Buric, M.; Lewis, R.; Seachman, S.
2015-05-01
One mission of the Crosscutting Technology Research program at the National Energy Technology Laboratory is to develop a suite of sensors and controls technologies that will ultimately increase efficiencies of existing fossil-fuel fired power plants and enable a new generation of more efficient and lower emission power generation technologies. The program seeks to accomplish this mission through soliciting, managing, and monitoring a broad range of projects both internal and external to the laboratory which span sensor material and device development, energy harvesting and wireless telemetry methodologies, and advanced controls algorithms and approaches. A particular emphasis is placed upon harsh environment sensing for compatibility with high temperature, erosive, corrosive, and highly reducing or oxidizing environments associated with large-scale centralized power generation. An overview of the full sensors and controls portfolio is presented and a selected set of current and recent research successes and on-going projects are highlighted. A more detailed emphasis will be placed on an overview of the current research thrusts and successes of the in-house sensor material and device research efforts that have been established to support the program.
NASA Technical Reports Server (NTRS)
Shaver, Charles; Williamson, Michael
1986-01-01
The NASA Ames Research Center sponsors a research program for the investigation of Intelligent Flight Control Actuation systems. The use of artificial intelligence techniques in conjunction with algorithmic techniques for autonomous, decentralized fault management of flight-control actuation systems is explored under this program. The design, development, and operation of the interface for laboratory investigation of this program is documented. The interface, architecturally based on the Intel 8751 microcontroller, is an interrupt-driven system designed to receive a digital message from an ultrareliable fault-tolerant control system (UFTCS). The interface links the UFTCS to an electronic servo-control unit, which controls a set of hydraulic actuators. It was necessary to build a UFTCS emulator (also based on the Intel 8751) to provide signal sources for testing the equipment.
Online automatic tuning and control for fed-batch cultivation
van Straten, Gerrit; van der Pol, Leo A.; van Boxtel, Anton J. B.
2007-01-01
Performance of controllers applied in biotechnological production is often below expectation. Online automatic tuning has the capability to improve control performance by adjusting control parameters. This work presents automatic tuning approaches for model reference specific growth rate control during fed-batch cultivation. The approaches are direct methods that use the error between observed specific growth rate and its set point; systematic perturbations of the cultivation are not necessary. Two automatic tuning methods proved to be efficient, in which the adaptation rate is based on a combination of the error, squared error and integral error. These methods are relatively simple and robust against disturbances, parameter uncertainties, and initialization errors. Application of the specific growth rate controller yields a stable system. The controller and automatic tuning methods are qualified by simulations and laboratory experiments with Bordetella pertussis. PMID:18157554
NASA Technical Reports Server (NTRS)
Sud, Y. C.; Chao, Winston C.; Walker, G. K.
1992-01-01
The influence of a cumulus convection scheme on the simulated atmospheric circulation and hydrologic cycle is investigated by means of a coarse version of the GCM. Two sets of integrations, each containing an ensemble of three summer simulations, were produced. The ensemble sets of control and experiment simulations are compared and differentially analyzed to determine the influence of a cumulus convection scheme on the simulated circulation and hydrologic cycle. The results show that cumulus parameterization has a very significant influence on the simulation circulation and precipitation. The upper-level condensation heating over the ITCZ is much smaller for the experiment simulations as compared to the control simulations; correspondingly, the Hadley and Walker cells for the control simulations are also weaker and are accompanied by a weaker Ferrel cell in the Southern Hemisphere. Overall, the difference fields show that experiment simulations (without cumulus convection) produce a cooler and less energetic atmosphere.
Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L
2018-03-01
There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.
Paulovich, Amanda G.; Billheimer, Dean; Ham, Amy-Joan L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Tabb, David L.; Wang, Pei; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Clauser, Karl R.; Kinsinger, Christopher R.; Schilling, Birgit; Tegeler, Tony J.; Variyath, Asokan Mulayath; Wang, Mu; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fenyo, David; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Mesri, Mehdi; Neubert, Thomas A.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Stein, Stephen E.; Tempst, Paul; Liebler, Daniel C.
2010-01-01
Optimal performance of LC-MS/MS platforms is critical to generating high quality proteomics data. Although individual laboratories have developed quality control samples, there is no widely available performance standard of biological complexity (and associated reference data sets) for benchmarking of platform performance for analysis of complex biological proteomes across different laboratories in the community. Individual preparations of the yeast Saccharomyces cerevisiae proteome have been used extensively by laboratories in the proteomics community to characterize LC-MS platform performance. The yeast proteome is uniquely attractive as a performance standard because it is the most extensively characterized complex biological proteome and the only one associated with several large scale studies estimating the abundance of all detectable proteins. In this study, we describe a standard operating protocol for large scale production of the yeast performance standard and offer aliquots to the community through the National Institute of Standards and Technology where the yeast proteome is under development as a certified reference material to meet the long term needs of the community. Using a series of metrics that characterize LC-MS performance, we provide a reference data set demonstrating typical performance of commonly used ion trap instrument platforms in expert laboratories; the results provide a basis for laboratories to benchmark their own performance, to improve upon current methods, and to evaluate new technologies. Additionally, we demonstrate how the yeast reference, spiked with human proteins, can be used to benchmark the power of proteomics platforms for detection of differentially expressed proteins at different levels of concentration in a complex matrix, thereby providing a metric to evaluate and minimize preanalytical and analytical variation in comparative proteomics experiments. PMID:19858499
Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L
2008-11-01
Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.
2004-01-01
nerve stimulation combined with an inspiratory impedance threshold in a pig model of hemorrhagic shock. Crit Care Med 2003; 31:1197–1202 16. Coast JR...training. Because of the po- tential effects on cardiovascular function, sub- jects refrained from exercise and stimulants such as caffeine and other...controlled trial. Setting: Laboratory. Subjects: Ten women and ten men. Interventions: We measured hemodynamic and respiratory re- sponses during two
2009-07-11
NASA mission managers watch the latest weather radar on a monitor in Firing Room Four of the Launch Control Center at NASA's Kennedy Space Center in Cape Canaveral, Florida, Sunday, July 12, 2009. Endeavour is set to launch at 7:13p.m. EDT with the crew of STS-127 and start a 16-day mission that will feature five spacewalks and complete construction of the Japan Aerospace Exploration Agency's Kibo laboratory. Photo Credit: (NASA/Bill Ingalls)
2009-07-11
Bob Cabana, Director of NASA's Kennedy Space Center talks with other mission managers in Firing Room Four of the Launch Control Center at NASA's Kennedy Space Center in Cape Canaveral, Florida, Sunday, July 12, 2009. Endeavour is set to launch at 7:13p.m. EDT with the crew of STS-127 and start a 16-day mission that will feature five spacewalks and complete construction of the Japan Aerospace Exploration Agency's Kibo laboratory. Photo Credit: (NASA/Bill Ingalls)
Low-frequency outdoor-indoor noise level difference for wind turbine assessment.
Thorsson, Pontus; Persson Waye, Kerstin; Smith, Michael; Ögren, Mikael; Pedersen, Eja; Forssén, Jens
2018-03-01
To increase the understanding of wind turbine noise on sleep, human physiological reactions need to be studied in a controlled laboratory setting. The paper presents an outdoor-indoor noise level difference as a function of frequency, applicable to creating wind turbine indoor sounds with the outdoor sounds as input. For this, a combination of measurement data and modeling results has been used. The suggested data are provided in a table.
1976-08-01
can easily change any of the parameters controlling the r, experimenter. B.2.3.3 The PLATO Laborato >• A block diagram of the laboratory is...the parameters of an adaptive filter, or to perform the computations required by the more complex displays. In addition to its role as the prime...by the inherent response variability which precludes reliable estimates of attention-sensitive parameters from a single observation. Thus
Wade, Matthew; Isom, Ryan; Georgescu, Dan; Olson, Randall J
2007-06-01
To determine the efficacy of the Cruise Control surge-limiting device (Staar Surgical) with phacoemulsification machines known to have high levels of surge. John A. Moran Eye Center Clinical Laboratories. In an in vitro study, postocclusion anterior chamber depth changes were measured in fresh phakic human eye-bank eyes using the Alcon Legacy and Bausch & Lomb Millennium venturi machines in conjunction with the Staar Cruise Control device. Both machines were tested with 19-gauge non-Aspiration Bypass System tips at high-surge settings (500 mm Hg vacuum pressure, 75 cm bottle height, 40 mL/min flow rate for the Legacy) and low-surge settings (400 mm Hg vacuum pressure, 125 cm bottle height, 40 mL/min flow rate for the Legacy). Adjusted parameters of flow, vacuum, and irrigation were used based on previous studies to create identical conditions for each device tested. The effect of the Cruise Control device on aspiration rates was also tested with both machines at the low-surge settings. At the high setting with the addition of Cruise Control, surge decreased significantly with the Legacy but was too large to measure with the Millennium venturi. At the low setting with the addition of Cruise Control, surge decreased significantly with both machines. Surge with the Millennium decreased from more than 1.0 mm to a mean of 0.21 mm +/- 0.02 (SD) (P<.0001). Surge with the Legacy decreased from a mean of 0.09 +/- 0.02 mm to 0.05 +/- 0 mm, a 42.9% decrease (P<.0001). The Millennium had the highest surge and aspiration rate before Cruise Control and the greatest percentage decrease in the surge and aspiration rates as a result of the addition of Cruise Control. In the Legacy machine, the Cruise Control device had a statistically and clinically significant effect. Cruise Control had a large effect on fluidics as well as surge amplitude with the Millennium machine. The greater the flow or greater the initial surge, the greater the impact of the Cruise Control device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loong, H.; Liang, C.C.; Tseng, K.T.
1988-01-01
The use of microcomputer control system to gas-fired kiln not only enhanced the porcelain kiln's productivity from 75% to 95% but also saved its operation cost around US$ 200,000 per year. The self-designed microcomputer control system can simultaneous set and control the firing conditions of the period kiln which was built up in our laboratory. Our period kiln having volume of 4 M/sup 3/ was insulated by ceramic fiber which is different from use of refractory in traditional kilns. At the bottom of the kiln is an off-gas tunnel connected with a chimney. Besides the auto start-up and continuous operationmore » of kiln, the main functions of this microcomputer control system are summarized.« less
Piccinonna, Sara; Ragone, Rosa; Stocchero, Matteo; Del Coco, Laura; De Pascali, Sandra Angelica; Schena, Francesco Paolo; Fanizzi, Francesco Paolo
2016-05-15
Nuclear Magnetic Resonance (NMR) spectroscopy is emerging as a powerful technique in olive oil fingerprinting, but its analytical robustness has to be proved. Here, we report a comparative study between two laboratories on olive oil (1)H NMR fingerprinting, aiming to demonstrate the robustness of NMR-based metabolomics in generating comparable data sets for cultivar classification. Sample preparation and data acquisition were performed independently in two laboratories, equipped with different resolution spectrometers (400 and 500 MHz), using two identical sets of mono-varietal olive oils. Partial Least Squares (PLS)-based techniques were applied to compare the data sets produced by the two laboratories. Despite differences in spectrum baseline, and in intensity and shape of peaks, the amount of shared information was significant (almost 70%) and related to cultivar (same metabolites discriminated between cultivars). In conclusion, regardless of the variability due to operator and machine, the data sets from the two participating units were comparable for the purpose of classification. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Singleton, Jered; Zentner, Chris; Buser, Josh; Yager, Paul; LaBarre, Paul; Weigl, Bernhard H.
2013-03-01
Many infectious diseases, as well as some cancers, that affect global health are most accurately diagnosed through nucleic acid amplification and detection. There is a great need to simplify nucleic acid-based assay systems for use in global health in low-resource settings as well as in settings that do not have convenient access to laboratory staff and equipment such as doctors' offices and home care settings. In developing countries, unreliable electric power, inadequate supply chains, and lack of maintenance for complex diagnostic instruments are all common infrastructure shortfalls. Many elements of instrument-free, disposable, nucleic acid amplification assays have been demonstrated in recent years. However, the problem of instrument-free,1 low-cost, temperature-controlled chemical heating remains unsolved. In this paper we present the current status and results of work towards developing disposable, low-cost, temperature-controlled heaters designed to support isothermal nucleic acid amplification assays that are integrated with a two-dimensional paper network. Our approach utilizes the heat generated through exothermic chemical reactions and controls the heat through use of engineered phase change materials to enable sustained temperatures required for nucleic acid amplification. By selecting appropriate exothermic and phase change materials, temperatures can be controlled over a wide range, suitable for various isothermal amplification methods, and maintained for over an hour at an accuracy of +/- 1°C.
Singleton, Jered; Zentner, Chris; Buser, Josh; Yager, Paul; LaBarre, Paul; Weigl, Bernhard H
2013-03-09
Many infectious diseases, as well as some cancers, that affect global health are most accurately diagnosed through nucleic acid amplification and detection. There is a great need to simplify nucleic acid-based assay systems for use in global health in low-resource settings as well as in settings that do not have convenient access to laboratory staff and equipment such as doctors' offices and home care settings. In developing countries, unreliable electric power, inadequate supply chains, and lack of maintenance for complex diagnostic instruments are all common infrastructure shortfalls. Many elements of instrument-free, disposable, nucleic acid amplification assays have been demonstrated in recent years. However, the problem of instrument-free, low-cost, temperature-controlled chemical heating remains unsolved. In this paper we present the current status and results of work towards developing disposable, low-cost, temperature-controlled heaters designed to support isothermal nucleic acid amplification assays that are integrated with a two-dimensional paper network. Our approach utilizes the heat generated through exothermic chemical reactions and controls the heat through use of engineered phase change materials to enable sustained temperatures required for nucleic acid amplification. By selecting appropriate exothermic and phase change materials, temperatures can be controlled over a wide range, suitable for various isothermal amplification methods, and maintained for over an hour at an accuracy of +/- 1°C.
Singleton, Jered; Zentner, Chris; Buser, Josh; Yager, Paul; LaBarre, Paul; Weigl, Bernhard H.
2014-01-01
Many infectious diseases, as well as some cancers, that affect global health are most accurately diagnosed through nucleic acid amplification and detection. There is a great need to simplify nucleic acid-based assay systems for use in global health in low-resource settings as well as in settings that do not have convenient access to laboratory staff and equipment such as doctors' offices and home care settings. In developing countries, unreliable electric power, inadequate supply chains, and lack of maintenance for complex diagnostic instruments are all common infrastructure shortfalls. Many elements of instrument-free, disposable, nucleic acid amplification assays have been demonstrated in recent years. However, the problem of instrument-free,1 low-cost, temperature-controlled chemical heating remains unsolved. In this paper we present the current status and results of work towards developing disposable, low-cost, temperature-controlled heaters designed to support isothermal nucleic acid amplification assays that are integrated with a two-dimensional paper network. Our approach utilizes the heat generated through exothermic chemical reactions and controls the heat through use of engineered phase change materials to enable sustained temperatures required for nucleic acid amplification. By selecting appropriate exothermic and phase change materials, temperatures can be controlled over a wide range, suitable for various isothermal amplification methods, and maintained for over an hour at an accuracy of +/- 1°C. PMID:25426269
Design and test of a simulation system for autonomous optic-navigated planetary landing
NASA Astrophysics Data System (ADS)
Cai, Sheng; Yin, Yanhe; Liu, Yanjun; He, Fengyun
2018-02-01
In this paper, a simulation system based on commercial projector is proposed to test the optical navigation algorithms for autonomous planetary landing in laboratorial scenarios. The design work of optics, mechanics and synchronization control are carried out. Furthermore, the whole simulation system is set up and tested. Through the calibration of the system, two main problems, synchronization between the projector and CCD and pixel-level shifting caused by the low repeatability of DMD used in the projector, are settled. The experimental result shows that the RMS errors of pitch, yaw and roll angles are 0.78', 0.48', and 2.95' compared with the theoretical calculation, which can fulfill the requirement of experimental simulation for planetary landing in laboratory.
Where do we store the memory representations that guide attention?
Woodman, Geoffrey F.; Carlisle, Nancy B.; Reinhart, Robert M. G.
2013-01-01
During the last decade one of the most contentious and heavily studied topics in the attention literature has been the role that working memory representations play in controlling perceptual selection. The hypothesis has been advanced that to have attention select a certain perceptual input from the environment, we only need to represent that item in working memory. Here we summarize the work indicating that the relationship between what representations are maintained in working memory and what perceptual inputs are selected is not so simple. First, it appears that attentional selection is also determined by high-level task goals that mediate the relationship between working memory storage and attentional selection. Second, much of the recent work from our laboratory has focused on the role of long-term memory in controlling attentional selection. We review recent evidence supporting the proposal that working memory representations are critical during the initial configuration of attentional control settings, but that after those settings are established long-term memory representations play an important role in controlling which perceptual inputs are selected by mechanisms of attention. PMID:23444390
Sadowski, Brett W; Lane, Alison B; Wood, Shannon M; Robinson, Sara L; Kim, Chin Hee
2017-09-01
Inappropriate testing contributes to soaring healthcare costs within the United States, and teaching hospitals are vulnerable to providing care largely for academic development. Via its "Choosing Wisely" campaign, the American Board of Internal Medicine recommends avoiding repetitive testing for stable inpatients. We designed systems-based interventions to reduce laboratory orders for patients admitted to the wards at an academic facility. We identified the computer-based order entry system as an appropriate target for sustainable intervention. The admission order set had allowed multiple routine tests to be ordered repetitively each day. Our iterative study included interventions on the automated order set and cost displays at order entry. The primary outcome was number of routine tests controlled for inpatient days compared with the preceding year. Secondary outcomes included cost savings, delays in care, and adverse events. Data were collected over a 2-month period following interventions in sequential years and compared with the year prior. The first intervention led to 0.97 fewer laboratory tests per inpatient day (19.4%). The second intervention led to sustained reduction, although by less of a margin than order set modifications alone (15.3%). When extrapolating the results utilizing fees from the Centers for Medicare and Medicaid Services, there was a cost savings of $290,000 over 2 years. Qualitative survey data did not suggest an increase in care delays or near-miss events. This series of interventions targeting unnecessary testing demonstrated a sustained reduction in the number of routine tests ordered, without adverse effects on clinical care. Published by Elsevier Inc.
Modernisation of the intermediate physics laboratory
NASA Astrophysics Data System (ADS)
Kontro, Inkeri; Heino, Olga; Hendolin, Ilkka; Galambosi, Szabolcs
2018-03-01
The intermediate laboratory courses at the Department of Physics, University of Helsinki, were reformed using desired learning outcomes as the basis for design. The reformed laboratory courses consist of weekly workshops and small-group laboratory sessions. Many of the laboratory exercises are open-ended and have several possible ways of execution. They were designed around affordable devices, to allow for the purchase of multiple sets of laboratory equipment. This allowed students to work on the same problems simultaneously. Thus, it was possible to set learning goals which build on each other. Workshop sessions supported the course by letting the students solve problems related to conceptual and technical aspects of each laboratory exercise. The laboratory exercises progressed biweekly to allow for iterative problem solving. Students reached the learning goals well and the reform improved student experiences. Neither positive or negative changes in expert-like attitudes towards experimental physics (measured by E-CLASS questionnaire) were observed.
Preparation and validation of gross alpha/beta samples used in EML`s quality assessment program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scarpitta, S.C.
1997-10-01
A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory`s (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ({sup 241}Am, {sup 230}Th and {sup 238}Pu) andmore » beta ({sup 90}Sr/{sup 90}Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tandon, Lav; Kuhn, Kevin J; Drake, Lawrence R
Los Alamos National Laboratory's (LANL) Actinide Analytical Chemistry (AAC) group has been in existence since the Manhattan Project. It maintains a complete set of analytical capabilities for performing complete characterization (elemental assay, isotopic, metallic and non metallic trace impurities) of uranium and plutonium samples in different forms. For a majority of the customers there are strong quality assurance (QA) and quality control (QC) objectives including highest accuracy and precision with well defined uncertainties associated with the analytical results. Los Alamos participates in various international and national programs such as the Plutonium Metal Exchange Program, New Brunswick Laboratory's (NBL' s) Safeguardsmore » Measurement Evaluation Program (SME) and several other inter-laboratory round robin exercises to monitor and evaluate the data quality generated by AAC. These programs also provide independent verification of analytical measurement capabilities, and allow any technical problems with analytical measurements to be identified and corrected. This presentation will focus on key analytical capabilities for destructive analysis in AAC and also comparative data between LANL and peer groups for Pu assay and isotopic analysis.« less
Integrating teaching and research in the field and laboratory settings
NASA Astrophysics Data System (ADS)
Wang, L.; Kaseke, K. F.; Daryanto, S.; Ravi, S.
2015-12-01
Field observations and laboratory measurements are great ways to engage students and spark students' interests in science. Typically these observations are separated from rigorous classroom teaching. Here we assessed the potential of integrating teaching and research in the field and laboratory setting in both US and abroad and worked with students without strong science background to utilize simple laboratory equipment and various environmental sensors to conduct innovative projects. We worked with students in Namibia and two local high school students in Indianapolis to conduct leaf potential measurements, soil nutrient extraction, soil infiltration measurements and isotope measurements. The experience showed us the potential of integrating teaching and research in the field setting and working with people with minimum exposure to modern scientific instrumentation to carry out creative projects.
An easy-to-build remote laboratory with data transfer using the Internet School Experimental System
NASA Astrophysics Data System (ADS)
Schauer, František; Lustig, František; Dvořák, Jiří; Ožvoldová, Miroslava
2008-07-01
The present state of information communication technology makes it possible to devise and run computer-based e-laboratories accessible to any user with a connection to the Internet, equipped with very simple technical means and making full use of web services. Thus, the way is open for a new strategy of physics education with strongly global features, based on experiment and experimentation. We name this strategy integrated e-learning, and remote experiments across the Internet are the foundation for this strategy. We present both pedagogical and technical reasoning for the remote experiments and outline a simple system based on a server-client approach, and on web services and Java applets. We give here an outline of the prospective remote laboratory system with data transfer using the Internet School Experimental System (ISES) as hardware and ISES WEB Control kit as software. This approach enables the simple construction of remote experiments without building any hardware and virtually no programming, using a paste and copy approach with typical prebuilt blocks such as a camera view, controls, graphs, displays, etc. We have set up and operate at present seven experiments, running round the clock, with more than 12 000 connections since 2005. The experiments are widely used in practical teaching of both university and secondary level physics. The recording of the detailed steps the experimentor takes during the measurement enables detailed study of the psychological aspects of running the experiments. The system is ready for a network of universities to start covering the basic set of physics experiments. In conclusion we summarize the results achieved and experiences of using remote experiments built on the ISES hardware system.
Albajar-Viñas, Pedro; Wilkins, Patricia P.; Nieto, Javier; Leiby, David A.; Paris, Luc; Scollo, Karenina; Flórez, Carolina; Guzmán-Bracho, Carmen; Luquetti, Alejandro O.; Calvo, Nidia; Tadokoro, Kenji; Saez-Alquezar, Amadeo; Palma, Pedro Pablo; Martin, Miguel
2014-01-01
Chagas disease is one of the main public health issues in Latin America. Increasingly during the past few decades, Trypanosoma cruzi infection has been detected in North America, Europe, and the Western Pacific, mainly as a result of population movement. The limited availability of rapid serological diagnostic tests hinders rapid diagnosis and early treatment in areas of endemicity and nonendemicity. In collaboration with 11 national reference laboratories (NRLs) from different geographical areas, we evaluated the performances of commercialized serological rapid diagnostic tests (RDT) for T. cruzi infection. Eleven commercialized T. cruzi infection RDTs were evaluated on a total of 474 samples extensively tested with at least three different techniques for Chagas disease, maintained at controlled low temperatures, and stored in the serum banks of the 11 NRLs. We measured the sensitivity, specificity, and concordance of each RDT and provided an additional questionnaire to evaluate its ease of use. The selected RDTs in this study were performed under controlled laboratory conditions. Out of the 11 RDTs, we found 8 of them to be useful, with the cassette format favored over the strip. We did not observe significant differences in RDT performances in the different regions. Overall, the performance results were lower than those disclosed by the manufacturers. The results of this evaluation validate the possibility of using RDTs to diagnose Chagas disease, thereby decreasing the time to treatment at a primary health care facility for patients who are willing to be treated. Further studies should be conducted in the laboratory and in the field to confirm these data, expressly to evaluate reproducibility in resource-limited settings, or using whole blood in clinical settings in areas of endemicity and nonendemicity. PMID:24808239
Muirhead, K A; Wallace, P K; Schmitt, T C; Frescatore, R L; Franco, J A; Horan, P K
1986-01-01
As the diagnostic utility of lymphocyte subset analysis has been recognized in the clinical research laboratory, a wide variety of reagents and cell preparation, staining and analysis methods have also been described. Methods that are perfectly suitable for analysis of smaller sample numbers in the biological or clinical research setting are not always appropriate and/or applicable in the setting of a high volume clinical reference laboratory. We describe here some of the specific considerations involved in choosing a method for flow cytometric analysis which minimizes sample preparation and data analysis time while maximizing sample stability, viability, and reproducibility. Monoclonal T- and B-cell reagents from three manufacturers were found to give equivalent results for a reference population of healthy individuals. This was true whether direct or indirect immunofluorescence staining was used and whether cells were prepared by Ficoll-Hypaque fractionation (FH) or by lysis of whole blood. When B cells were enumerated using a polyclonal anti-immunoglobulin reagent, less cytophilic immunoglobulin staining was present after lysis than after FH preparation. However, both preparation methods required additional incubation at 37 degrees C to obtain results concordant with monoclonal B-cell reagents. Standard reagents were chosen on the basis of maximum positive/negative separation and the availability of appropriate negative controls. The effects of collection medium and storage conditions on sample stability and reproducibility of subset analysis were also assessed. Specimens collected in heparin and stored at room temperature in buffered medium gave reproducible results for 3 days after specimen collection, using either FH or lysis as the preparation method. General strategies for instrument optimization, quality control, and biohazard containment are also discussed.
Accuracy of three Android-based pedometer applications in laboratory and free-living settings.
Leong, Jia Yan; Wong, Jyh Eiin
2017-01-01
This study examines the accuracy of three popular, free Android-based pedometer applications (apps), namely, Runtastic (RT), Pacer Works (PW), and Tayutau (TY) in laboratory and free-living settings. Forty-eight adults (22.5 ± 1.4 years) completed 3-min bouts of treadmill walking at five incremental speeds while carrying a test smartphone installed with the three apps. Experiment was repeated thrice, with the smartphone placed either in the pants pockets, at waist level, or secured to the left arm by an armband. The actual step count was manually counted by a tally counter. In the free-living setting, each of the 44 participants (21.9 ± 1.6 years) carried a smartphone with installed apps and a reference pedometer (Yamax Digi-Walker CW700) for 7 consecutive days. Results showed that TY produced the lowest mean absolute percent error (APE 6.7%) and was the only app with acceptable accuracy in counting steps in a laboratory setting. RT consistently underestimated steps with APE of 16.8% in the laboratory. PW significantly underestimated steps when the smartphone was secured to the arm, but overestimated under other conditions (APE 19.7%). TY was the most accurate app in counting steps in a laboratory setting with the lowest APE of 6.7%. In the free-living setting, the APE relative to the reference pedometer was 16.6%, 18.0%, and 16.8% for RT, PW, and TY, respectively. None of the three apps counted steps accurately in the free-living setting.
21 CFR 226.58 - Laboratory controls.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Laboratory controls. 226.58 Section 226.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control § 226.58 Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test...
21 CFR 226.58 - Laboratory controls.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory controls. 226.58 Section 226.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control § 226.58 Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test...
21 CFR 226.58 - Laboratory controls.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Laboratory controls. 226.58 Section 226.58 Food...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Product Quality Control § 226.58 Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test...
Human factors in telemanipulation: Perspectives from the Oak Ridge National Laboratory experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Draper, J.V.
1994-01-01
Personnel at the Robotics and Process Systems Division (RPSD) of the Oak Ridge National Laboratory (ORNL) have extensive experience designing, building, and operating teleoperators for a variety of settings, including space, battlefields, nuclear fuel reprocessing plants, and hazardous waste retrieval. In the course of the last decade and a half, the RPSD designed, built, and operated 4 telemanipulators (M-2, ASM, LTM, CESAR arm) and operated another half dozen (M-8, Model 50, TOS SM-229, RM-10, PaR 5000, BilArm 83A). During this period, human factors professionals have been closely integrated with RPSD design teams, investigating telemanipulator feedback and feed forward, designing cockpitsmore » and control rooms, training users and designers, and helping to develop performance specifications for telemanipulators. This paper presents a brief review of this and other work, with an aim towards providing perspectives on some of the human factors aspects of telemanipulation. The first section of the paper examines user tasks during supervisory control and discusses how telemanipulator responsiveness determines the appropriate control metaphor for continuous manual control. The second section provides an ecological perspective on telemanipulator feedback and feed-forward. The third section briefly describes the RPSD control room design approach and how design projects often serve as systems integrators.« less
Does olfactory specific satiety take place in a natural setting?
Fernandez, P; Bensafi, M; Rouby, C; Giboreau, A
2013-01-01
Olfactory-specific satiety (OSS) is characterized by a specific decrease in the odor pleasantness of a food eaten to satiety or smelled without ingestion. The usual protocol for studying OSS takes place in laboratory, a setting rather removed from the real world. Here, we set out to examine OSS in a natural setting: during a meal in a restaurant. We hypothesized that an aroma contained in a food that is eaten at the beginning of a meal decreases the pleasantness of the flavor of a food with the same aroma eaten at the end of the meal. In the first experiment (Experiment 1), a test group received an appetizer flavored with a test aroma (anise) at the beginning of the meal. After the main dish, they received a dessert flavored with the same aroma. A control group received the same aromatized dessert, but after a non-aromatized appetizer. This experiment was replicated (Experiment 2) using verbena as the test aroma. For both experiments, results revealed that aroma pleasantness, but not intensity or familiarity, significantly decreased in the test groups vs. the control groups. These findings extend the concept of OSS to a realistic eating context. Copyright © 2012 Elsevier Ltd. All rights reserved.
Noel, Krista M.; Qualls, Carl P.; Ennen, Joshua R.
2012-01-01
Recent studies have found that Gopher Tortoise, Gopherus polyphemus, populations in southern Mississippi exhibit low recruitment, due in part to very low hatching success of their eggs. We sought to determine if the cause(s) of this low hatching success was related to egg quality (intrinsic factors), unsuitability of the nest environment (extrinsic factors), or a combination of the two. In 2003, hatching success was monitored simultaneously for eggs from the same clutches that were incubated in the laboratory and left to incubate in nests. A subset of randomly chosen eggs from each clutch was incubated in the laboratory under physical conditions that were known to be conducive to successful hatching to estimate the proportion of eggs that were capable of hatching in a controlled setting. Hatching success in the laboratory was compared with that of eggs incubated in natural nests to estimate the proportion of eggs that failed to hatch presumably from extrinsic factors. Laboratory hatching success was 58.8%, suggesting that roughly 40% of the eggs were intrinsically incapable of hatching even when incubated under controlled conditions. Hatching success in natural nests, 16.7%, was significantly lower than hatching success in the laboratory, suggesting that approximately 42.1% of eggs were capable of hatching but failed to hatch due to some extrinsic aspect(s) of the nest environment. Thus, the low hatching success of Gopher Tortoise eggs in southern Mississippi appears to be attributable to a combination of intrinsic (egg quality) and extrinsic (nest environment) factors.
A theoretical and experimental study of wood planer noise and its control
NASA Technical Reports Server (NTRS)
Stewart, J. S.
1972-01-01
A combined analytical and experimental study of wood planer noise is made and the results applied to the development of practical noise control techniques. The dominant mechanisms of sound generation are identified and an analysis is presented which accurately predicts the governing levels of noise emission. Planing operations in which the length of the board is much greater than the width are considered. The dominant source of planer noise is identified as the board being surfaced, which is set into vibration by the impact of cutterhead knives. This is determined from studies made both in the laboratory and in the field concerning the effect of board width on the resulting noise, which indicate a six decibel increase in noise level for each doubling of board width. The theoretical development of a model for board vibration defines the vibrational field set up in the board and serves as a guide for cutterhead redesign.
Loudspeaker line array educational demonstration.
Anderson, Brian E; Moser, Brad; Gee, Kent L
2012-03-01
This paper presents a physical demonstration of an audio-range line array used to teach interference of multiple sources in a classroom or laboratory exercise setting. Software has been developed that permits real-time control and steering of the array. The graphical interface permits a user to vary the frequency, the angular response by phase shading, and reduce sidelobes through amplitude shading. An inexpensive, eight-element loudspeaker array has been constructed to test the control program. Directivity measurements of this array in an anechoic chamber and in a large classroom are presented. These measurements have good agreement with theoretical directivity predictions, thereby allowing its use as a quantitative learning tool for advanced students as well as a qualitative demonstration of arrays in other settings. Portions of this paper are directed toward educators who may wish to implement a similar demonstration for their advanced undergraduate or graduate level course in acoustics. © 2012 Acoustical Society of America
Begolo, Stefano; Zhukov, Dmitriy V; Selck, David A; Li, Liang; Ismagilov, Rustem F
2014-12-21
Equipment-free pumping is a challenging problem and an active area of research in microfluidics, with applications for both laboratory and limited-resource settings. This paper describes the pumping lid method, a strategy to achieve equipment-free pumping by controlled generation of pressure. Pressure was generated using portable, lightweight, and disposable parts that can be integrated with existing microfluidic devices to simplify workflow and eliminate the need for pumping equipment. The development of this method was enabled by multi-material 3D printing, which allows fast prototyping, including composite parts that combine materials with different mechanical properties (e.g. both rigid and elastic materials in the same part). The first type of pumping lid we describe was used to produce predictable positive or negative pressures via controlled compression or expansion of gases. A model was developed to describe the pressures and flow rates generated with this approach and it was validated experimentally. Pressures were pre-programmed by the geometry of the parts and could be tuned further even while the experiment was in progress. Using multiple lids or a composite lid with different inlets enabled several solutions to be pumped independently in a single device. The second type of pumping lid, which relied on vapor-liquid equilibrium to generate pressure, was designed, modeled, and experimentally characterized. The pumping lid method was validated by controlling flow in different types of microfluidic applications, including the production of droplets, control of laminar flow profiles, and loading of SlipChip devices. We believe that applying the pumping lid methodology to existing microfluidic devices will enhance their use as portable diagnostic tools in limited resource settings as well as accelerate adoption of microfluidics in laboratories.
21 CFR 58.219 - Reinstatement of a disqualified testing facility.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Disqualification of Testing... disqualified may be reinstated as an acceptable source of nonclinical laboratory studies to be submitted to the... laboratory studies in compliance with the good laboratory practice regulations set forth in this part and, if...
21 CFR 58.219 - Reinstatement of a disqualified testing facility.
Code of Federal Regulations, 2011 CFR
2011-04-01
... SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Disqualification of Testing... disqualified may be reinstated as an acceptable source of nonclinical laboratory studies to be submitted to the... laboratory studies in compliance with the good laboratory practice regulations set forth in this part and, if...
Golda, Rachel L; Golda, Mark D; Peterson, Tawnya D; Needoba, Joseph A
2017-06-01
The influence of pH on phytoplankton physiology is an important facet of the body of research on ocean acidification. We provide data developed during the design and implementation of a novel pHstat system capable of maintaining both static and dynamic pH environments in a laboratory setting. These data both help improve functionality of the system, and provide specific coding blocks for controlling the pHstat using a LabVIEW® virtual instrument (VI). The data in this paper support the research article "Development of an economical, autonomous pHstat system for culturing phytoplankton under steady state or dynamic conditions" (Golda et al. [2]). These data will be of interest to researchers studying the effects of changing pH on phytoplankton in a laboratory context, and to those desiring to build their own pHstat system(s). These data can also be used to facilitate modification of the pHstat system to control salinity, temperature, or other environmental factors.
Casner, Stephen M; Schooler, Jonathan W
2015-09-01
In laboratory studies of vigilance, participants watch for unusual events in a "sit and stare" fashion as their performance typically declines over time. But watch keepers in practical settings seldom approach monitoring in such simplistic ways and controlled environments. We observed airline pilots performing routine monitoring duties in the cockpit. Unlike laboratory studies, pilots' monitoring did not deteriorate amidst prolonged vigils. Monitoring was frequently interrupted by other pop-up tasks and misses followed. However, when free from these distractions, pilots reported copious mind wandering. Pilots often confined their mind wandering to times in which their monitoring performance would not conspicuously suffer. But when no convenient times were available, pilots mind wandered anyway and misses ensued. Real-world monitors may be caught between a continuous vigilance approach that is doomed to fail, a dynamic environment that cannot be fully controlled, and what may be an irresistible urge to let one's thoughts drift. Published by Elsevier Inc.
Human rabies in Tianjin, China.
Montgomery, J P; Zhang, Y; Wells, E V; Liu, Y; Clayton, J L; Wang, X; Boulton, M L
2012-12-01
Human rabies has recently re-emerged as a significant public health threat in Tianjin, China. Using surveillance data compiled by the Tianjin Centers for Disease Control and Prevention, we describe 60 cases of human rabies reported from 2005 to 2011 in the municipality of Tianjin, China. All 60 cases of human rabies resulted in death. Cases were primarily male (80%), middle aged (mean 40.6 years), and exposed to rabies in a rural setting (82%). Most exposures were associated with dog bites (93%) and no animal had a history of rabies vaccination; no cases were laboratory confirmed. Fifteen percent of patients sought medical attention for their wound, and none received a complete regimen of WHO-recommended post-exposure prophylaxis (PEP). These findings suggest the need for China's public health authority to improve animal rabies surveillance and control strategies through laboratory case confirmation, more rapid response to potential exposures with provision of appropriate PEP, and education to the public and to health care providers on identifying and reducing rabies risk.
Assessing the impact of different satellite retrieval methods on forecast available potential energy
NASA Technical Reports Server (NTRS)
Whittaker, Linda M.; Horn, Lyle H.
1990-01-01
The effects of the inclusion of satellite temperature retrieval data, and of different satellite retrieval methods, on forecasts made with the NASA Goddard Laboratory for Atmospheres (GLA) fourth-order model were investigated using, as the parameter, the available potential energy (APE) in its isentropic form. Calculation of the APE were used to study the differences in the forecast sets both globally and in the Northern Hemisphere during 72-h forecast period. The analysis data sets used for the forecasts included one containing the NESDIS TIROS-N retrievals, the GLA retrievals using the physical inversion method, and a third, which did not contain satellite data, used as a control; two data sets, with and without satellite data, were used for verification. For all three data sets, the Northern Hemisphere values for the total APE showed an increase throughout the forecast period, mostly due to an increase in the zonal component, in contrast to the verification sets, which showed a steady level of total APE.
Minion, Jessica; Pai, Madhukar; Ramsay, Andrew; Menzies, Dick; Greenaway, Christina
2011-01-01
Introduction Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. Methods In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. Results There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. Conclusions Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used. PMID:21811622
Stave, Gregg M
2018-02-16
This review explores animal allergen exposure in research laboratories and other work settings, focusing on causes and prevention. (1) Consistent with the hygiene hypothesis, there is new evidence that early childhood exposure to pets produces changes in the gut microbiome that likely lead to a lower risk of allergy. (2) Anaphylaxis from laboratory animal bites occurs more frequently than suggested by prior literature. (3) Animal allergens represent an occupational hazard in a wide variety of work settings ranging from fields that work with animals to public settings like schools and public transportation where allergens are brought into or are present in the workplace. Exposure to animal allergens can result in allergy, asthma, and anaphylaxis. Animal allergy has been most studied in the research laboratory setting, where exposure reduction can prevent the development of allergy. Similar prevention approaches need to be considered for other animal work environments and in all settings where animal allergens are present.
Biosafety Level 3 Recon Training
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dickens, Brian Scott; Chavez, Melanie Ann; Heimer, Donovan J.
The Biosafety Level 3 Recon training is a 3D virtual tool developed for the Counter WMD Analysis Cell (CWAC) and the Asymmetric Warfare Group (AWG) by the Application Modeling and Development Team within the NEN-3 International Threat Reduction Group. The training simulates a situation where friendly forces have secured from hostile forces a suspected bioweapons development laboratory. The trainee is a squad member tasked to investigate the facility, locate laboratories within the facility, and identify hazards to entrants and the surrounding area. Before beginning the 3D simulation, the trainee must select the appropriate MOPP level for entering the facility. Themore » items in the simulation, including inside and outside the bioweapon facility, are items that are commonly used by scientists in Biosafety Level (BSL) laboratories. Each item has clickable red tags that, when activated, give the trainee a brief description of the item and a controllable turn-around view. The descriptions also contain information about potential hazards the item can present. Trainees must find all tagged items in order to complete the simulation, but can also reference descriptions and turn-around view of the items in a glossary menu. Training is intended to familiarize individuals whom have little or no biology or chemistry background with technical equipment used in BSL laboratories. The revised edition of this simulation (Biosafety Level 3 Virtual Lab) changes the trainee into a investigator instead of a military combatant. Many doors now require a virtual badge swipe to open. Airlock doors may come in sets such that the open door must be closed before the next door in the set can be opened. A user interface was added so that the instructor can edit the information about the items (the brief descriptions mentioned above) using the simulation software instead of the previous method of manually entering the material in xml settings files. Facility labels, such as "No Parking" and "Men's room", were changed from Korean, into English. No other changes were made.« less
Thorup, Kasper; Holland, Richard A; Tøttrup, Anders P; Wikelski, Martin
2010-09-01
For many years, orientation in migratory birds has primarily been studied in the laboratory. Although a laboratory-based setting enables greater control over environmental cues, the laboratory-based findings must be confirmed in the wild in free-flying birds to be able to fully understand how birds orient during migration. Despite the difficulties associated with following free-flying birds over long distances, a number of possibilities currently exist for tracking the long distance, sometimes even globe-spanning, journeys undertaken by migrating birds. Birds fitted with radio transmitters can either be located from the ground or from aircraft (conventional tracking), or from space. Alternatively, positional information obtained by onboard equipment (e.g., GPS units) can be transmitted to receivers in space. Use of these tracking methods has provided a wealth of information on migratory behaviors that are otherwise very difficult to study. Here, we focus on the progress in understanding certain components of the migration-orientation system. Comparably exciting results can be expected in the future from tracking free-flying migrants in the wild. Use of orientation cues has been studied in migrating raptors (satellite telemetry) and thrushes (conventional telemetry), highlighting that findings in the natural setting may not always be as expected on the basis of cage-experiments. Furthermore, field tracking methods combined with experimental approaches have finally allowed for an extension of the paradigmatic displacement experiments performed by Perdeck in 1958 on the short-distance, social migrant, the starling, to long-distance migrating storks and long-distance, non-socially migrating passerines. Results from these studies provide fundamental insights into the nature of the migratory orientation system that enables experienced birds to navigate and guide inexperienced, young birds to their species-specific winter grounds. © The Author 2010. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved.
Mondal, Dinesh; Ghosh, Prakash; Khan, Md Anik Ashfaq; Hossain, Faria; Böhlken-Fascher, Susanne; Matlashewski, Greg; Kroeger, Axel; Olliaro, Piero; Abd El Wahed, Ahmed
2016-05-13
Leishmania donovani (LD) is a protozoan parasite transmitted to humans from sand flies, which causes Visceral Leishmaniasis (VL). Currently, the diagnosis is based on presence of the anti-LD antibodies and clinical symptoms. Molecular diagnosis would require real-time PCR, which is not easy to implement at field settings. In this study, we report on the development and testing of a recombinase polymerase amplification (RPA) assay for the detection of LD. A genomic DNA sample was applied to determine the assay analytical sensitivity. The cross-reactivity of the assay was tested by DNA of Leishmania spp. and of pathogens considered for differential diagnosis. The clinical performance of the assay was evaluated on LD positive and negative samples. All results were compared with real-time PCR. To allow the use of the assay at field settings, a mobile suitcase laboratory (56 × 45.5 × 26.5 cm) was developed and operated at the local hospital in Mymensingh, Bangladesh. The LD RPA assay detected equivalent to one LD genomic DNA. The assay was performed at constant temperature (42 °C) in 15 min. The RPA assay also detected other Leishmania species (L. major, L. aethiopica and L. infantum), but did not identify nucleic acid of other pathogens. Forty-eight samples from VL, asymptomatic and post-kala-azar dermal leishmaniasis subjects were detected positive and 48 LD-negative samples were negative by both LD RPA and real-time PCR assays, which indicates 100 % agreement. The suitcase laboratory was successfully operated at the local hospital by using a solar-powered battery. DNA extraction was performed by a novel magnetic bead based method (SpeedXtract), in which a simple fast lysis protocol was applied. Moreover, All reagents were cold-chain independent. The mobile suitcase laboratory using RPA is ideal for rapid sensitive and specific detection of LD especially at low resource settings and could contribute to VL control and elimination programmes.
The Potential of Virtual Reality for the Investigation of Awe
Chirico, Alice; Yaden, David B.; Riva, Giuseppe; Gaggioli, Andrea
2016-01-01
The emotion of awe is characterized by the perception of vastness and a need for accommodation, which can include a positive and/or negative valence. While a number of studies have successfully manipulated this emotion, the issue of how to elicit particularly intense awe experiences in laboratory settings remains. We suggest that virtual reality (VR) is a particularly effective mood induction tool for eliciting awe. VR provides three key assets for improving awe. First, VR provides users with immersive and ecological yet controlled environments that can elicit a sense of “presence,” the subjective experience of “being there” in a simulated reality. Further, VR can be used to generate complex, vast stimuli, which can target specific theoretical facets of awe. Finally, VR allows for convenient tracking of participants’ behavior and physiological responses, allowing for more integrated assessment of emotional experience. We discussed the potential and challenges of the proposed approach with an emphasis on VR’s capacity to raise the signal of reactions to emotions such as awe in laboratory settings. PMID:27881970
The Harvard Pigeon Lab under Herrnstein.
Baum, William M
2002-01-01
The history of the Harvard Pigeon Lab is a history of two periods of remarkable productivity, the first under Skinner's leadership and the second under Herrnstein's. In each period, graduate students flocked to the leader and then began stimulating one another. Chance favored Herrnstein's leadership, too, because an unusually large number of graduate students were admitted in the fall of 1962. In each period, productivity declined as the leader lost interest in the laboratory and withdrew. Directly and indirectly, the laboratory finally died as a result of the cognitive "revolution." Skinner and his students saw the possibility of a natural science of behavior and set about establishing that science based on concepts such as response rate, stimulus control, and schedules of reinforcement. Herrnstein and his students saw that the science could be quantitative and set about making it so, with relative response rate, the matching law, and the psychophysics of choice (analogous to S. S. Stevens' psychophysics). The history might provide a golden research opportunity for someone interested in the impact of such self-organizing research groups on the progress of science. PMID:12083686
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reimus, Paul William; Zavarin, Mavrik; Wang, Yifeng
2017-01-25
This report provides an overview of the current state of knowledge of colloid-facilitated radionuclide transport from a nuclear waste repository risk assessment perspective. It draws on work that has been conducted over the past 3 decades, although there is considerable emphasis given to work that has been performed over the past 3-5 years as part of the DOE Used Fuel Disposition Campaign. The timing of this report coincides with the completion of a 3-year DOE membership in the Colloids Formation and Migration (CFM) partnership, an international collaboration of scientists studying colloid-facilitated transport of radionuclides at both the laboratory and field-scalesmore » in a fractured crystalline granodiorite at the Grimsel Test Site in Switzerland. This Underground Research Laboratory has hosted the most extensive and carefully-controlled set of colloid-facilitated solute transport experiments that have ever been conducted in an in-situ setting, and a summary of the results to date from these efforts, as they relate to transport over long time and distance scales, is provided in Chapter 3 of this report.« less
Blended Learning within an Undergraduate Exercise Physiology Laboratory
ERIC Educational Resources Information Center
Elmer, Steven J.; Carter, Kathryn R.; Armga, Austin J.; Carter, Jason R.
2016-01-01
In physiological education, blended course formats (integration of face-to-face and online instruction) can facilitate increased student learning, performance, and satisfaction in classroom settings. There is limited evidence on the effectiveness of using blending course formats in laboratory settings. We evaluated the impact of blended learning…
Mars Science Laboratory Workstation Test Set
NASA Technical Reports Server (NTRS)
Henriquez, David A.; Canham, Timothy K.; Chang, Johnny T.; Villaume, Nathaniel
2009-01-01
The Mars Science Laboratory developed the Workstation TestSet (WSTS) is a computer program that enables flight software development on virtual MSL avionics. The WSTS is the non-real-time flight avionics simulator that is designed to be completely software-based and run on a workstation class Linux PC.
2009-07-11
John P. Shannon, Manager, NASA Space Shuttle Program Office watches the latest weather radar in Firing Room Four of the Launch Control Center at NASA's Kennedy Space Center in Cape Canaveral, Florida, Sunday, July 12, 2009. Endeavour is set to launch at 7:13p.m. EDT with the crew of STS-127 and start a 16-day mission that will feature five spacewalks and complete construction of the Japan Aerospace Exploration Agency's Kibo laboratory. Photo Credit: (NASA/Bill Ingalls)
Russ, Alissa L; Weiner, Michael; Russell, Scott A; Baker, Darrell A; Fahner, W Jeffrey; Saleem, Jason J
2012-12-01
Although the potential benefits of more usable health information technologies (HIT) are substantial-reduced HIT support costs, increased work efficiency, and improved patient safety--human factors methods to improve usability are rarely employed. The US Department of Veterans Affairs (VA) has emerged as an early leader in establishing usability laboratories to inform the design of HIT, including its electronic health record. Experience with a usability laboratory at a VA Medical Center provides insights on how to design, implement, and leverage usability laboratories in the health care setting. The VA Health Services Research and Development Service Human-Computer Interaction & Simulation Laboratory emerged as one of the first VA usability laboratories and was intended to provide research-based findings about HIT designs. This laboratory supports rapid prototyping, formal usability testing, and analysis tools to assess existing technologies, alternative designs, and potential future technologies. RESULTS OF IMPLEMENTATION: Although the laboratory has maintained a research focus, it has become increasingly integrated with VA operations, both within the medical center and on a national VA level. With this resource, data-driven recommendations have been provided for the design of HIT applications before and after implementation. The demand for usability testing of HIT is increasing, and information on how to develop usability laboratories for the health care setting is often needed. This article may assist other health care organizations that want to invest in usability resources to improve HIT. The establishment and utilization of usability laboratories in the health care setting may improve HIT designs and promote safe, high-quality care for patients.
Laboratory scale bioremediation of diesel hydrocarbon in soil by indigenous bacterial consortium.
Sharma, Anjana; Rehman, Meenal Budholia
2009-09-01
In vitro experiment was performed by taking petrol pump soils and diesel in flasks with the micronutrients and macronutrients supplements. Cemented bioreactors having sterilized soil and diesel was used for in vivo analysis of diesel hydrocarbon degradation. There were two sets of experiments, first having three bioreactors (1) inoculated by KI. pneumoniae subsp. aerogenes with soil and diesel; (2) with addition of NH4NO3; and (3) served as control. In second set, one bioreactor was inoculated by bacterial consortium containing Moraxella saccharolytica, Alteromonas putrefaciens, KI. pneumoniae subsp. aerogenes and Pseudomonas fragi along with soil and diesel. The remaining two bioreactors (having NH4NO3 and control) were similar to the first set. The experiments were incubated for 30 days. Ability of bacterial inoculum to degrade diesel was analyzed through GC-MS. Smaller chain compounds were obtained after experimental period of 30 days. Rate of diesel degradation was better with the present bacterial consortium than individual bacteria. Present bacterial consortium can be a better choice for faster and complete remediation of contaminated hydrocarbon soils.
Application of peer instruction in the laboratory task of measuring the effective mass of a spring
NASA Astrophysics Data System (ADS)
Zhang, Chun-Ling; Hou, Zhen-Yu; Si, Yu-Chang; Wen, Xiao-Qing; Tang, Lei
2017-11-01
Peer instruction (PI) is an effective interactive approach to teaching and learning that has principally been used to modify the experience of learning in traditional physics lecture settings. This article further illustrates how the concept of PI can be effectively applied in the physics student laboratory setting. The setting used is a laboratory task that calls for the measurement of the effective mass of the spring of a Jolly balance. Through PI the students gain a better understanding of what is meant by the construct ‘effective mass of a spring’, and thereby competently work out how the mass, shape, wire diameter, and number of turns of the spring can all affect the effective mass of the spring. Furthermore, using stopwatches the students were also able to appreciate how recorded times at the equilibrium position had greater uncertainty than measurements made at the maximum displacement. This led to their calculations of the effective mass of the spring being impressively close to the theoretical value. Such laboratory tasks are extremely challenging to introductory level students and the success attained by the students in this study indicates that there is much potential in the application of PI in laboratory settings. PI should be used to teach in the laboratory and results should be reported in order for our community to build on these experiences. This article is a contribution to that effort.
Florkowski, Christopher; Don-Wauchope, Andrew; Gimenez, Nuria; Rodriguez-Capote, Karina; Wils, Julien; Zemlin, Annalise
Point-of-care testing (POCT) is the analysis of patient specimens outside the clinical laboratory, near or at the site of patient care, usually performed by clinical staff without laboratory training, although it also encompasses patient self-monitoring. It is able to provide a rapid result near the patient and which can be acted upon immediately. The key driver is the concept that clinical decision making may be delayed when samples are sent to the clinical laboratory. Balanced against this are considerations of increased costs for purchase and maintenance of equipment, staff training, connectivity to the laboratory information system (LIS), quality control (QC) and external quality assurance (EQA) procedures, all required for accreditation under ISO 22870. The justification for POCT depends upon being able to demonstrate that a more timely result (shorter turnaround times (TATs)) is able to leverage a clinically important advantage in decision making compared with the central laboratory (CL). In the four decades since POCT was adapted for the self-monitoring of blood glucose levels by subjects with diabetes, numerous new POCT methodologies have become available, enabling the clinician to receive results and initiate treatment more rapidly. However, these instruments are often operated by staff not trained in laboratory medicine and hence are prone to errors in the analytical phase (as opposed to laboratory testing where the analytical phase has the least errors). In some environments, particularly remote rural settings, the CL may be at a considerable distance and timely availability of cardiac troponins and other analytes can triage referrals to the main centers, thus avoiding expensive unnecessary patient transportation costs. However, in the Emergency Department, availability of more rapid results with POCT does not always translate into shorter stays due to other barriers to implementation of care. In this review, we apply the principles of evidence-based laboratory medicine (EBLM) looking for high quality systematic reviews and meta-analyses, ideally underpinned by randomized controlled trials (RCTs), looking for evidence of whether POCT confers any advantage in clinical decision making in different scenarios.
NASA Technical Reports Server (NTRS)
Chiang, W.-W.; Cannon, R. H., Jr.
1985-01-01
A fourth-order laboratory dynamic system featuring very low structural damping and a noncolocated actuator-sensor pair has been used to test a novel real-time adaptive controller, implemented in a minicomputer, which consists of a state estimator, a set of state feedback gains, and a frequency-locked loop for real-time parameter identification. The adaptation algorithm employed can correct controller error and stabilize the system for more than 50 percent variation in the plant's natural frequency, compared with a 10 percent stability margin in frequency variation for a fixed gain controller having the same performance as the nominal plant condition. The very rapid convergence achievable by this adaptive system is demonstrated experimentally, and proven with simple, root-locus methods.
McGoldrick, Daryl J; Durham, Jeremy; Leknes, Henriette; Kierkegaard, Amelie; Gerhards, Reinhard; Powell, David E; McLachlan, Michael S
2011-11-01
Cyclic volatile methyl siloxanes (cVMS) are high volume production chemicals used in a wide range of industrial and consumer products. Three cVMS compounds (D4, D5, and D6) have and are undergoing environmental risk evaluations in several countries and have been proposed for legal regulation in Canada. As interest in monitoring concentrations of these chemicals in the environment increase, there is a need to evaluate the analytical procedures for cVMS in biological matrices in order to assess the quality of data produced. The purpose of this study was to determine laboratory testing performance for measuring residues of D4, D5, and D6 in a standard set of fish homogenate samples and to estimate limits of determination for each substance. The samples sent to each laboratory consisted of homogenized whole body tissues of hatchery raised rainbow trout which were fed food fortified with D4, D5, and D6 (dosed) and trout that were fed standard food rations (control). The participants analyzed each sample using their analytical method of choice using their own standards and procedures for quantification and quality control. With a few exceptions, participating laboratories generated comparable results for D4, D5, and D6 in both the dosed and control samples having z-scores between 2 and -2. Method detection limits for the whole fish matrix were on average 2.4 ng g(-1) ww for D4, 2.3 ng g(-1) ww for D5, and 1.8 ng g(-1) ww for D6. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
Wilkinson, D J; Thompson, J M; Lambert, G W; Jennings, G L; Schwarz, R G; Jefferys, D; Turner, A G; Esler, M D
1998-06-01
The sympathetic nervous system has long been believed to be involved in the pathogenesis of panic disorder, but studies to date, most using peripheral venous catecholamine measurements, have yielded conflicting and equivocal results. We tested sympathetic nervous function in patients with panic disorder by using more sensitive methods. Sympathetic nervous and adrenal medullary function was measured by using direct nerve recording (clinical microneurography) and whole-body and cardiac catecholamine kinetics in 13 patients with panic disorder as defined by the DSM-IV, and 14 healthy control subjects. Measurements were made at rest, during laboratory stress (forced mental arithmetic), and, for 4 patients, during panic attacks occurring spontaneously in the laboratory setting. Muscle sympathetic activity, arterial plasma concentration of norepinephrine, and the total and cardiac norepinephrine spillover rates to plasma were similar in patients and control subjects at rest, as was whole-body epinephrine secretion. Epinephrine spillover from the heart was elevated in patients with panic disorder (P=.01). Responses to laboratory mental stress were almost identical in patient and control groups. During panic attacks, there were marked increases in epinephrine secretion and large increases in the sympathetic activity in muscle in 2 patients but smaller changes in the total norepinephrine spillover to plasma. Whole-body and regional sympathetic nervous activity are not elevated at rest in patients with panic disorder. Epinephrine is released from the heart at rest in patients with panic disorder, possibly due to loading of cardiac neuronal stores by uptake from plasma during surges of epinephrine secretion in panic attacks. Contrary to popular belief, the sympathetic nervous system is not globally activated during panic attacks.
Chiou, Wen-Bin; Wu, Wen-Hsiung; Chang, Ming-Hsu
2013-05-01
Inadequate self-control has been linked to behavioural and impulse-control problems such as overeating, alcohol and drug abuse and smoking. Construal-level theory (CLT) suggests that a high-level construal (highlighting central goals associated with an event), relative to a low-level construal (highlighting means and resources), promotes self-control. Inspired by CLT, we examined whether smokers primed with a high-level (versus low-level) construal mind-set would show reductions in smoking that might be mediated by improved self-control. A single-factor (construal level: high, low, control) between-subjects design was employed. We used a widely employed why/how paradigm to induce high/low construal levels, whereby participants were asked to respond to questions about 'why' or 'how' they would maintain good physical health. Laboratory at Kaohsiung Medical University, Taiwan. A community sample consisting of 102 daily smokers participated in this experiment. The Stroop task measuring self-control was implemented after the construal-level manipulation. The dependent measure was actual cigarette consumption during an ostensible survey. Participants in a high-level construal mind-set smoked fewer cigarettes [mean = 1.3, 95% confidence interval (CI): 0.9, 1.7] than those in a low-level construal mind-set (mean = 2.6, 95% CI: 2.2, 3.0; P < 0.01). A bootstrapping analysis supported for the role of self-control (B = -1.14, 95% CI: -1.65, -0.74, P < 0.01) as a mechanism underlying this effect. Smokers primed with a high-level construal mind-set (i.e. cognitive abstraction) may induce greater self-control that leads to reduced cigarette consumption. Thus, reminding smokers to think abstractly about health may be an effective strategy that could help them to smoke fewer cigarettes. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.
A New Resource for College Distance Education Astronomy Laboratory Exercises
ERIC Educational Resources Information Center
Vogt, Nicole P.; Cook, Stephen P.; Muise, Amy Smith
2013-01-01
This article introduces a set of distance education astronomy laboratory exercises for use by college students and instructors and discusses first usage results. This General Astronomy Education Source exercise set contains eight two-week projects designed to guide students through both core content and mathematical applications of general…
MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi
2016-01-01
Rationale Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Objective Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. Setting 6 major hospitals in 2 districts of Beijing, China. Design Cluster randomised controlled trial. Participants 245 index cases with ILI. Intervention Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Main outcome measure Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. Results In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. Conclusions The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. Trial registration number ACTRN12613000852752; Results. PMID:28039289
Outbreak of Escherichia coli 0157:H7 related to animal contact at a petting zoo
Warshawsky, Bryna; Gutmanis, Iris; Henry, Bonnie; Dow, Joanne; Reffle, Jim; Pollett, Graham; Ahmed, Rafiq; Aldom, John; Alves, David; Chagla, Abdul; Ciebin, Bruce; Kolbe, Faron; Jamieson, Frances; Rodgers, Frank
2002-01-01
OBJECTIVE: To determine the cause of an outbreak of Escherichia coli 0157:H7 related to animal exposures so that further transmission could be prevented. DESIGN: Description of laboratory investigations and a case control study. SETTING: Agricultural pavilion at an annual fair in Ontario. POPULATION: People with laboratory evidence of E coli 0157:H7 (seven people) and others with diarrhea (155 people) who called the health unit following a media release were interviewed. Animals that were accessed most frequently by the public in the agriculture pavilion were tested for E coli 0157:H7. In the case control study, a case was defined as someone with laboratory confirmed E coli 0157:H7, or someone who developed severe or bloody diarrhea two to eight days after attending the agricultural pavilion at the fair (61 people). A convenience sample of people who attended the agricultural pavilion but did not develop diarrhea was selected as the control group (89 people). INTERVENTIONS: Human and animal E coli 0157:H7 specimens were subtyped. Cases and controls were interviewed using a standardized questionnaire. RESULTS: Subtyping of the seven human isolates of E coli 0157:H7 revealed five that were of an extremely uncommon phage type. Three samples from goats and one from sheep at the petting zoo in the agricultural pavilion were of this same phage type. The case control study also implicated goats (odds ratio [OR] 3.65; 95% CI 1.63 to 8.52) and sheep (OR 2.94; 95% CI 1.33 to 6.57) from the petting zoo. CONCLUSIONS: Results of this investigation suggest strongly that the goats and sheep from the petting zoo were the source of this outbreak of E coli 0157:H7. PMID:18159389
Braithwaite, Jeffrey; Clay-Williams, Robyn; Vecellio, Elia; Marks, Danielle; Hooper, Tamara; Westbrook, Mary; Westbrook, Johanna; Blakely, Brette; Ludlow, Kristiana
2016-01-01
Objectives To examine the basis of multidisciplinary teamwork. In real-world healthcare settings, clinicians often cluster in profession-based tribal silos, form hierarchies and exhibit stereotypical behaviours. It is not clear whether these social structures are more a product of inherent characteristics of the individuals or groups comprising the professions, or attributable to a greater extent to workplace factors. Setting Controlled laboratory environment with well-appointed, quiet rooms and video and audio equipment. Participants Clinical professionals (n=133) divided into 35 groups of doctors, nurses and allied health professions, or mixed professions. Interventions Participants engaged in one of three team tasks, and their performance was video-recorded and assessed. Primary and secondary measures Primary: teamwork performance. Secondary, pre-experimental: a bank of personality questionnaires designed to assess participants’ individual differences. Postexperimental: the 16-item Mayo High Performance Teamwork Scale (MHPTS) to measure teamwork skills; this was self-assessed by participants and also by external raters. In addition, external, arm's length blinded observations of the videotapes were conducted. Results At baseline, there were few significant differences between the professions in collective orientation, most of the personality factors, Machiavellianism and conservatism. Teams generally functioned well, with effective relationships, and exhibited little by way of discernible tribal or hierarchical behaviours, and no obvious differences between groups (F (3, 31)=0.94, p=0.43). Conclusions Once clinicians are taken out of the workplace and put in controlled settings, tribalism, hierarchical and stereotype behaviours largely dissolve. It is unwise therefore to attribute these factors to fundamental sociological or psychological differences between individuals in the professions, or aggregated group differences. Workplace cultures are more likely to be influential in shaping such behaviours. The results underscore the importance of culture and context in improvement activities. Future initiatives should factor in culture and context as well as individuals’ or professions’ characteristics as the basis for inducing more lateral teamwork or better interprofessional collaboration. PMID:27473955
Clinical bacteriology in low-resource settings: today's solutions.
Ombelet, Sien; Ronat, Jean-Baptiste; Walsh, Timothy; Yansouni, Cedric P; Cox, Janneke; Vlieghe, Erika; Martiny, Delphine; Semret, Makeda; Vandenberg, Olivier; Jacobs, Jan
2018-03-05
Low-resource settings are disproportionately burdened by infectious diseases and antimicrobial resistance. Good quality clinical bacteriology through a well functioning reference laboratory network is necessary for effective resistance control, but low-resource settings face infrastructural, technical, and behavioural challenges in the implementation of clinical bacteriology. In this Personal View, we explore what constitutes successful implementation of clinical bacteriology in low-resource settings and describe a framework for implementation that is suitable for general referral hospitals in low-income and middle-income countries with a moderate infrastructure. Most microbiological techniques and equipment are not developed for the specific needs of such settings. Pending the arrival of a new generation diagnostics for these settings, we suggest focus on improving, adapting, and implementing conventional, culture-based techniques. Priorities in low-resource settings include harmonised, quality assured, and tropicalised equipment, consumables, and techniques, and rationalised bacterial identification and testing for antimicrobial resistance. Diagnostics should be integrated into clinical care and patient management; clinically relevant specimens must be appropriately selected and prioritised. Open-access training materials and information management tools should be developed. Also important is the need for onsite validation and field adoption of diagnostics in low-resource settings, with considerable shortening of the time between development and implementation of diagnostics. We argue that the implementation of clinical bacteriology in low-resource settings improves patient management, provides valuable surveillance for local antibiotic treatment guidelines and national policies, and supports containment of antimicrobial resistance and the prevention and control of hospital-acquired infections. Copyright © 2018 Elsevier Ltd. All rights reserved.
Amerson, Megan H; Pulido, Lila; Garza, Melinda N; Ali, Faheem A; Greenhill, Brandy; Einspahr, Christopher L; Yarsa, Joseph; Sood, Pramilla K; Hu, Peter C
2012-01-01
The University of Texas M.D. Anderson Cancer Center, Division of Pathology and Laboratory Medicine is committed to providing the best pathology and medicine through: state-of-the art techniques, progressive ground-breaking research, education and training for the clinical diagnosis and research of cancer and related diseases. After surveying the laboratory staff and other hospital professionals, the Department administrators and Human Resource generalists developed a professional development model for Microbiology to support laboratory skills, behavior, certification, and continual education within its staff. This model sets high standards for the laboratory professionals to allow the labs to work at their fullest potential; it provides organization to training technologists based on complete laboratory needs instead of training technologists in individual areas in which more training is required if the laboratory needs them to work in other areas. This model is a working example for all microbiology based laboratories who want to set high standards and want their staff to be acknowledged for demonstrated excellence and professional development in the laboratory. The PDM model is designed to focus on the needs of the laboratory as well as the laboratory professionals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wade, F. E.
The Chemical Synthesis Pilot Process at the Lawrence Livermore National Laboratory (LLNL) Site 300 827 Complex will be used to synthesize small quantities of material to support research and development. The project will modernize and increase current capabilities for chemical synthesis at LLNL. The primary objective of this project is the conversion of a non-automated hands-on process to a remoteoperation process, while providing enhanced batch process step control, stored recipe-specific parameter sets, process variable visibility, monitoring, alarm and warning handling, and comprehensive batch record data logging. This Statement of Work and Specification provides the industrial-grade process control requirements for themore » chemical synthesis batching control system, hereafter referred to as the “Control System” to be delivered by the System Integrator.« less
A Biomarker Bakeoff in Early Stage Pancreatic Cancer — EDRN Public Portal
Previous research in EDRN laboratories and elsewhere has produced several candidate biomarker(s) for the detection of early-stage pancreatic ductal adenocarcinoma (PDAC), many of which show promise for significantly improving upon the performance of the current best marker, CA19-9. As yet, the relative performance of the markers in combination is not known because a rigorous comparison using a common sample set has not been performed. A direct comparison of the potential biomarkers in a comparative study (“biomarker bakeoff”) would enable an objective determination of which candidates should move forward for further validation, as well as an assessment of the potential value of using novel combinations of the biomarkers. The gastrointestinal collaborative group within the EDRN is in an optimal position to carry out such a study given its shared resources and interactive structure. In this project, the two pancreatic CVCs in the EDRN will provide samples to be distributed to four laboratories with promising biomarkers. The laboratories will run their own assays and perform initial analyses on the blinded PDAC and control samples. Our biostatistical collaborator, Dr. Huang at FHCRC, will perform the statistical evaluations. Biomarkers meeting the predetermined performance criteria will move forward to further validation using the EDRN reference set. In addition, we will determine whether any novel combinations of biomarkers should be further tested.
Playing Tetris decreases drug and other cravings in real world settings.
Skorka-Brown, Jessica; Andrade, Jackie; Whalley, Ben; May, Jon
2015-12-01
Most research on cognitive processes in craving has been carried out in the laboratory and focuses on food craving. This study extends laboratory findings to real world settings and cravings for drugs or activities as well as food. Previous laboratory research has found that playing Tetris reduces craving strength. The present study used an ecological momentary assessment protocol in which 31 undergraduate participants carried iPods for a week and were prompted 7 times each day, by SMS message, to use their iPod to report craving. Participants reported craving target and strength (0-100), whether they indulged their previous craving (yes/no), and whether they were under the influence of alcohol (yes/no). Those randomly assigned to the intervention condition (n=15) then played Tetris for 3min and reported their craving again. Those in the monitoring-only control condition (n=16) provided baseline craving data to test if Tetris reduced the incidence and strength of spontaneous cravings across the week. Playing Tetris decreased craving strength for drugs (alcohol, nicotine, caffeine), food and drink, and activities (sex, exercise, gaming), with a mean reduction of 13.9 percentage points, effect size f(2)=0.11. This effect was consistent across the week. This is the first demonstration that visual cognitive interference can be used in the field to reduce cravings for substances and activities other than eating. Copyright © 2015 Elsevier Ltd. All rights reserved.
Some comparisons between mining-induced and laboratory earthquakes
McGarr, A.
1994-01-01
Although laboratory stick-slip friction experiments have long been regarded as analogs to natural crustal earthquakes, the potential use of laboratory results for understanding the earthquake source mechanism has not been fully exploited because of essential difficulties in relating seismographic data to measurements made in the controlled laboratory environment. Mining-induced earthquakes, however, provide a means of calibrating the seismic data in terms of laboratory results because, in contrast to natural earthquakes, the causative forces as well as the hypocentral conditions are known. A comparison of stick-slip friction events in a large granite sample with mining-induced earthquakes in South Africa and Canada indicates both similarities and differences between the two phenomena. The physics of unstable fault slip appears to be largely the same for both types of events. For example, both laboratory and mining-induced earthquakes have very low seismic efficiencies {Mathematical expression} where ??a is the apparent stress and {Mathematical expression} is the average stress acting on the fault plane to cause slip; nearly all of the energy released by faulting is consumed in overcoming friction. In more detail, the mining-induced earthquakes differ from the laboratory events in the behavior of ?? as a function of seismic moment M0. Whereas for the laboratory events ?????0.06 independent of M0, ?? depends quite strongly on M0 for each set of induced earthquakes, with 0.06 serving, apparently, as an upper bound. It seems most likely that this observed scaling difference is due to variations in slip distribution over the fault plane. In the laboratory, a stick-slip event entails homogeneous slip over a fault of fixed area. For each set of induced earthquakes, the fault area appears to be approximately fixed but the slip is inhomogeneous due presumably to barriers (zones of no slip) distributed over the fault plane; at constant {Mathematical expression}, larger events correspond to larger??a as a consequence of fewer barriers to slip. If the inequality ??a/ {Mathematical expression} ??? 0.06 has general validity, then measurements of ??a=??Ea/M0, where ?? is the modulus of rigidity and Ea is the seismically-radiated energy, can be used to infer the absolute level of deviatoric stress at the hypocenter. ?? 1994 Birkha??user Verlag.
Perceived Frequency of Peer-Assisted Learning in the Laboratory and Collegiate Clinical Settings
Henning, Jolene M.; Weidner, Thomas G.; Snyder, Melissa; Dudley, William N.
2012-01-01
Context: Peer-assisted learning (PAL) has been recommended as an educational strategy to improve students' skill acquisition and supplement the role of the clinical instructor (CI). How frequently students actually engage in PAL in different settings is unknown. Objective: To determine the perceived frequency of planned and unplanned PAL (peer modeling, peer feedback and assessment, peer mentoring) in different settings. Design: Cross-sectional study. Setting: Laboratory and collegiate clinical settings. Patients or Other Participants: A total of 933 students, 84 administrators, and 208 CIs representing 52 (15%) accredited athletic training education programs. Intervention(s): Three versions (student, CI, administrator) of the Athletic Training Peer Assisted Learning Survey (AT-PALS) were administered. Cronbach α values ranged from .80 to .90. Main Outcome Measure(s): Administrators' and CIs' perceived frequency of 3 PAL categories under 2 conditions (planned, unplanned) and in 2 settings (instructional laboratory, collegiate clinical). Self-reported frequency of students' engagement in 3 categories of PAL in 2 settings. Results: Administrators and CIs perceived that unplanned PAL (0.39 ± 0.22) occurred more frequently than planned PAL (0.29 ± 0.19) regardless of category or setting (F1,282 = 83.48, P < .001). They perceived that PAL occurred more frequently in the collegiate clinical (0.46 ± 0.22) than laboratory (0.21 ± 0.24) setting regardless of condition or category (F1,282 = 217.17, P < .001). Students reported engaging in PAL more frequently in the collegiate clinical (3.31 ± 0.56) than laboratory (3.26 ± 0.62) setting regardless of category (F1,860 = 13.40, P < .001). We found a main effect for category (F2,859 = 1318.02, P < .001), with students reporting they engaged in peer modeling (4.01 ± 0.60) more frequently than peer mentoring (2.99 ± 0.88) (P < .001) and peer assessment and feedback (2.86 ± 0.64) (P < .001). Conclusions: Participants perceived that students engage in unplanned PAL in the collegiate clinical setting with a stronger inclination toward engagement in peer modeling. Educators should develop planned PAL activities to capitalize on the inherent desire of the students to collaborate with their peers. PMID:22488288
NASA Technical Reports Server (NTRS)
Sammy, Mo
2010-01-01
Active flow control is often used to manipulate flow instabilities to achieve a desired goal (e.g. prevent separation, enhance mixing, reduce noise, etc.). Instability frequencies normally scale with flow velocity scale and inversely with flow length scale (U/l). In a laboratory setting for such flow experiments, U is high, but l is low, resulting in high instability frequency. In addition, high momentum and high background noise & turbulence in the flow necessitate high amplitude actuation. Developing a high amplitude and high frequency actuator is a major challenge. Ironically, these requirements ease up in application (but other issues arise).
Saskatchewan Forest Fire Control Centre Surface Meteorological Data
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Newcomer, Jeffrey A. (Editor); Funk, Barry; Strub, Richard
2000-01-01
The Saskatchewan Forest Fire Control Centre (SFFCC) provided surface meteorological data to BOREAS from its archive. This data set contains hourly surface meteorological data from 18 of the Meteorological stations located across Saskatchewan. Included in these data are parameters of date, time, temperature, relative humidity, wind direction, wind speed, and precipitation. Temporally, the data cover the period of May through September of 1994 and 1995. The data are provided in comma-delimited ASCII files, and are classified as AFM-Staff data. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
Altitude Wind Tunnel Control Room at the Aircraft Engine Research Laboratory
1944-07-21
Operators in the control room for the Altitude Wind Tunnel at the National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory remotely operate a Wright R–3350 engine in the tunnel’s test section. Four of the engines were used to power the B–29 Superfortress, a critical weapon in the Pacific theater during World War II. The wind tunnel, which had been in operation for approximately six months, was the nation’s only wind tunnel capable of testing full-scale engines in simulated altitude conditions. The soundproof control room was used to operate the wind tunnel and control the engine being run in the test section. The operators worked with assistants in the adjacent Exhauster Building and Refrigeration Building to manage the large altitude simulation systems. The operator at the center console controlled the tunnel’s drive fan and operated the engine in the test section. Two sets of pneumatic levers near his right forearm controlled engine fuel flow, speed, and cooling. Panels on the opposite wall, out of view to the left, were used to manage the combustion air, refrigeration, and exhauster systems. The control panel also displayed the master air speed, altitude, and temperature gauges, as well as a plethora of pressure, temperature, and airflow readings from different locations on the engine. The operator to the right monitored the manometer tubes to determine the pressure levels. Despite just being a few feet away from the roaring engine, the control room remained quiet during the tests.
Theme: Laboratory Instruction.
ERIC Educational Resources Information Center
Bruening, Thomas H.; And Others
1992-01-01
A series of theme articles discuss setting up laboratory hydroponics units, the school farm at the Zuni Pueblo in New Mexico, laboratory experiences in natural resources management and urban horticulture, the development of teaching labs at Derry (PA) High School, management of instructional laboratories, and industry involvement in agricultural…
NASA Astrophysics Data System (ADS)
Trevisan, L.; Illangasekare, T. H.; Rodriguez, D.; Sakaki, T.; Cihan, A.; Birkholzer, J. T.; Zhou, Q.
2011-12-01
Geological storage of carbon dioxide in deep geologic formations is being considered as a technical option to reduce greenhouse gas loading to the atmosphere. The processes associated with the movement and stable trapping are complex in deep naturally heterogeneous formations. Three primary mechanisms contribute to trapping; capillary entrapment due to immobilization of the supercritical fluid CO2 within soil pores, liquid CO2 dissolving in the formation water and mineralization. Natural heterogeneity in the formation is expected to affect all three mechanisms. A research project is in progress with the primary goal to improve our understanding of capillary and dissolution trapping during injection and post-injection process, focusing on formation heterogeneity. It is expected that this improved knowledge will help to develop site characterization methods targeting on obtaining the most critical parameters that capture the heterogeneity to design strategies and schemes to maximize trapping. This research combines experiments at the laboratory scale with multiphase modeling to upscale relevant trapping processes to the field scale. This paper presents the results from a set of experiments that were conducted in an intermediate scale test tanks. Intermediate scale testing provides an attractive alternative to investigate these processes under controlled conditions in the laboratory. Conducting these types of experiments is highly challenging as methods have to be developed to extrapolate the data from experiments that are conducted under ambient laboratory conditions to high temperatures and pressures settings in deep geologic formations. We explored the use of a combination of surrogate fluids that have similar density, viscosity contrasts and analogous solubility and interfacial tension as supercritical CO2-brine in deep formations. The extrapolation approach involves the use of dimensionless numbers such as Capillary number (Ca) and the Bond number (Bo). A set of experiments that captures some of the complexities of the geologic heterogeneity and injection scenarios are planned in a 4.8 m long tank. To test the experimental methods and instrumentation, a set of preliminary experiments were conducted in a smaller tank with dimensions 90 cm x 60 cm. The tank was packed to represent both homogeneous and heterogeneous conditions. Using the surrogate fluids, different injection scenarios were tested. Images of the migration plume showed the critical role that heterogeneity plays in stable entrapment. Destructive sampling done at the end of the experiments provided data on the final saturation distributions. Preliminary analysis suggests the entrapment configuration is controlled by the large-scale heterogeneities as well as the pore-scale entrapment mechanisms. The data was used in modeling analysis that is presented in a companion abstract.
Pratt, Victoria M.; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H.; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E.; Wu, Alan H.B.; Yeo, Kiang-Teck J.; Zeller, Markus; Kalman, Lisa
2010-01-01
Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research. PMID:20889555
Clay, Andrea W; Bloomsmith, Mollie A; Marr, M Jackson; Maple, Terry L
2009-01-01
Operant conditioning using positive reinforcement techniques has been used extensively in the management of nonhuman primates in both zoological and laboratory settings. This research project was intended to test the usefulness of counter-conditioning techniques in reducing the fear-responses of singly housed male rhesus macaques living in the laboratory environment. A total of 18 male rhesus macaques (Macaca mulatta) were selected for this project and randomly assigned to one of three groups: a desensitization training group, a husbandry training group, or a control group. Behavioral data were collected before and after a 6 weeks training and/or habituation period during which the first two groups received a total of 125 min of positive reinforcement training (and also were assumed to undergo habituation to the environment) and the control group experienced only simple habituation to the environment. Based on a Wilcoxon Matched-Pairs Sign Test, we found that a significant proportion of animals exposed to desensitization training showed a reduction in the rate at which they engaged in cringing toward humans (exact significance=0.016, one-tailed, N-ties=6), cringing in general (exact significance=0.016, one-tailed, N-ties=6), and in stress-related behaviors (exact significance=0.016, one-tailed, N-ties=6). This was not the case for animals exposed to basic husbandry training or animals in the control group. A significant proportion of desensitization-exposed animals also showed a reduction in the duration of time spent cringing toward humans (exact significance=0.016, one-tailed, N-ties=6), but not in cringing behaviors in general or in stress-related behaviors. There were not a significant proportion of animals in either the husbandry training group or the control group that showed a decrease in duration of these behaviors. Results of this study could enhance both laboratory animal welfare and laboratory animal research, and could be a first step in developing techniques for reducing fearful behavior in rhesus monkeys in the laboratory environment. (c) 2008 Wiley-Liss, Inc.
Temperature Control Diagnostics for Sample Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santodonato, Louis J; Walker, Lakeisha MH; Church, Andrew J
2010-01-01
In a scientific laboratory setting, standard equipment such as cryocoolers are often used as part of a custom sample environment system designed to regulate temperature over a wide range. The end user may be more concerned with precise sample temperature control than with base temperature. But cryogenic systems tend to be specified mainly in terms of cooling capacity and base temperature. Technical staff at scientific user facilities (and perhaps elsewhere) often wonder how to best specify and evaluate temperature control capabilities. Here we describe test methods and give results obtained at a user facility that operates a large sample environmentmore » inventory. Although this inventory includes a wide variety of temperature, pressure, and magnetic field devices, the present work focuses on cryocooler-based systems.« less
NASA Technical Reports Server (NTRS)
Mercer, Joey; Callantine, Todd; Martin, Lynne
2012-01-01
A recent human-in-the-loop simulation in the Airspace Operations Laboratory (AOL) at NASA's Ames Research Center investigated the robustness of Controller-Managed Spacing (CMS) operations. CMS refers to AOL-developed controller tools and procedures for enabling arrivals to conduct efficient Optimized Profile Descents with sustained high throughput. The simulation provided a rich data set for examining how a traffic management supervisor and terminal-area controller participants used the CMS tools and coordinated to respond to off-nominal events. This paper proposes quantitative measures for characterizing the participants responses. Case studies of go-around events, replicated during the simulation, provide insights into the strategies employed and the role the CMS tools played in supporting them.
Andrés-Toro, B; Girón-Sierra, J M; Fernández-Blanco, P; López-Orozco, J A; Besada-Portas, E
2004-04-01
This paper describes empirical research on the model, optimization and supervisory control of beer fermentation. Conditions in the laboratory were made as similar as possible to brewery industry conditions. Since mathematical models that consider realistic industrial conditions were not available, a new mathematical model design involving industrial conditions was first developed. Batch fermentations are multiobjective dynamic processes that must be guided along optimal paths to obtain good results. The paper describes a direct way to apply a Pareto set approach with multiobjective evolutionary algorithms (MOEAs). Successful finding of optimal ways to drive these processes were reported. Once obtained, the mathematical fermentation model was used to optimize the fermentation process by using an intelligent control based on certain rules.
The Hydrological Open Air Laboratory (HOAL) in Petzenkirchen: a hypothesis-driven observatory
NASA Astrophysics Data System (ADS)
Blöschl, G.; Blaschke, A. P.; Broer, M.; Bucher, C.; Carr, G.; Chen, X.; Eder, A.; Exner-Kittridge, M.; Farnleitner, A.; Flores-Orozco, A.; Haas, P.; Hogan, P.; Kazemi Amiri, A.; Oismüller, M.; Parajka, J.; Silasari, R.; Stadler, P.; Strauss, P.; Vreugdenhil, M.; Wagner, W.; Zessner, M.
2016-01-01
Hydrological observatories bear a lot of resemblance to the more traditional research catchment concept, but tend to differ in providing more long-term facilities that transcend the lifetime of individual projects, are more strongly geared towards performing interdisciplinary research, and are often designed as networks to assist in performing collaborative science. This paper illustrates how the experimental and monitoring set-up of an observatory, the 66 ha Hydrological Open Air Laboratory (HOAL) in Petzenkirchen, Lower Austria, has been established in a way that allows meaningful hypothesis testing. The overarching science questions guided site selection, identification of dissertation topics and the base monitoring. The specific hypotheses guided the dedicated monitoring and sampling, individual experiments, and repeated experiments with controlled boundary conditions. The purpose of the HOAL is to advance the understanding of water-related flow and transport processes involving sediments, nutrients and microbes in small catchments. The HOAL catchment is ideally suited for this purpose, because it features a range of different runoff generation processes (surface runoff, springs, tile drains, wetlands), the nutrient inputs are known, and it is convenient from a logistic point of view as all instruments can be connected to the power grid and a high-speed glassfibre local area network (LAN). The multitude of runoff generation mechanisms in the catchment provides a genuine laboratory where hypotheses of flow and transport can be tested, either by controlled experiments or by contrasting sub-regions of different characteristics. This diversity also ensures that the HOAL is representative of a range of catchments around the world, and the specific process findings from the HOAL are applicable to a variety of agricultural catchment settings. The HOAL is operated jointly by the Vienna University of Technology and the Federal Agency for Water Management and takes advantage of the Vienna Doctoral Programme on Water Resource Systems funded by the Austrian Science Funds. The paper presents the science strategy of the set-up of the observatory, discusses the implementation of the HOAL, gives examples of the hypothesis testing and summarises the lessons learned. The paper concludes with an outlook on future developments.
Experimental evidence of multimaterial jet formation with lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicolaie, Ph.; Stenz, C.; Tikhonchuk, V.
2010-11-15
Laser-produced multimaterial jets have been investigated at the Prague Asterix Laser System laser [K. Jungwirth et al., Phys. Plasmas 8, 2495 (2001)]. The method of jet production is based on the laser-plasma ablation process and proved to be easy to set up and robust. The possibility of multimaterial laboratory jet production is demonstrated and complex hydrodynamic flows in the jet body are obtained. Two complementary diagnostics in the optical ray and x-ray ranges provide detailed information about jet characteristics. The latter are in agreement with estimates and two-dimensional radiation hydrodynamic simulation results. The experiment provides a proof of principle thatmore » a velocity field could be produced and controlled in the jet body. It opens a possibility of astrophysical jet structure modeling in laboratory.« less
Wagner, David T; Barnes, Christopher M; Lim, Vivien K G; Ferris, D Lance
2012-09-01
The Internet is a powerful tool that has changed the way people work. However, the ubiquity of the Internet has led to a new workplace threat to productivity-cyberloafing. Building on the ego depletion model of self-regulation, we examine how lost and low-quality sleep influence employee cyberloafing behaviors and how individual differences in conscientiousness moderate these effects. We also demonstrate that the shift to Daylight Saving Time (DST) results in a dramatic increase in cyberloafing behavior at the national level. We first tested the DST-cyberloafing relation through a national quasi-experiment, then directly tested the relation between sleep and cyberloafing in a closely controlled laboratory setting. We discuss the implications of our findings for theory, practice, and future research.
Experimental Validation of a Resilient Monitoring and Control System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen-Chiao Lin; Kris R. E. Villez; Humberto E. Garcia
2014-05-01
Complex, high performance, engineering systems have to be closely monitored and controlled to ensure safe operation and protect public from potential hazards. One of the main challenges in designing monitoring and control algorithms for these systems is that sensors and actuators may be malfunctioning due to malicious or natural causes. To address this challenge, this paper addresses a resilient monitoring and control (ReMAC) system by expanding previously developed resilient condition assessment monitoring systems and Kalman filter-based diagnostic methods and integrating them with a supervisory controller developed here. While the monitoring and diagnostic algorithms assess plant cyber and physical health conditions,more » the supervisory controller selects, from a set of candidates, the best controller based on the current plant health assessments. To experimentally demonstrate its enhanced performance, the developed ReMAC system is then used for monitoring and control of a chemical reactor with a water cooling system in a hardware-in-the-loop setting, where the reactor is computer simulated and the water cooling system is implemented by a machine condition monitoring testbed at Idaho National Laboratory. Results show that the ReMAC system is able to make correct plant health assessments despite sensor malfunctioning due to cyber attacks and make decisions that achieve best control actions despite possible actuator malfunctioning. Monitoring challenges caused by mismatches between assumed system component models and actual measurements are also identified for future work.« less
Error identification in a high-volume clinical chemistry laboratory: Five-year experience.
Jafri, Lena; Khan, Aysha Habib; Ghani, Farooq; Shakeel, Shahid; Raheem, Ahmed; Siddiqui, Imran
2015-07-01
Quality indicators for assessing the performance of a laboratory require a systematic and continuous approach in collecting and analyzing data. The aim of this study was to determine the frequency of errors utilizing the quality indicators in a clinical chemistry laboratory and to convert errors to the Sigma scale. Five-year quality indicator data of a clinical chemistry laboratory was evaluated to describe the frequency of errors. An 'error' was defined as a defect during the entire testing process from the time requisition was raised and phlebotomy was done until the result dispatch. An indicator with a Sigma value of 4 was considered good but a process for which the Sigma value was 5 (i.e. 99.977% error-free) was considered well controlled. In the five-year period, a total of 6,792,020 specimens were received in the laboratory. Among a total of 17,631,834 analyses, 15.5% were from within hospital. Total error rate was 0.45% and of all the quality indicators used in this study the average Sigma level was 5.2. Three indicators - visible hemolysis, failure of proficiency testing and delay in stat tests - were below 5 on the Sigma scale and highlight the need to rigorously monitor these processes. Using Six Sigma metrics quality in a clinical laboratory can be monitored more effectively and it can set benchmarks for improving efficiency.
Flint, Robert W.; Hill, Jonathan E.; Sandusky, Leslie A.; Marino, Christina L.
2007-01-01
Undergraduate neuroscience laboratory activities frequently focus on exercises that build student’s wet/dry laboratory skills, foster critical thinking, and provide opportunities for hands-on experiences. Such activities are, without a doubt, extremely important, but sometimes fall short of modeling actual research and often lack the ‘unknown’ hypothetical nature accompanying empirical studies. In this article we report a series of research activities using an animal model of Korsakoff’s syndrome in a Physiological Psychology course. The activities involve testing hypotheses regarding performance of animals with experimentally-induced Korsakoff’s syndrome and the effectiveness of glucose as a memory-enhancer in this model. Students were given a set of 24 articles for use in answering a series of laboratory report questions regarding the activities. At the conclusion of the course, students were asked to complete a questionnaire designed to assess the effectiveness of the laboratory activities. Results of the laboratory exercises indicated that locomotor activity, environmental habituation, and anxiety were unaffected in the Korsakoff condition, and glucose had no effect. Results of performance in the T-maze indicated that Korsakoff animals had significantly fewer spontaneous alternations than controls, but Korsakoff animals given glucose did not reveal this difference. Results of the student assessments indicated that the activities were considered educational, challenging, and more interesting than standard laboratory activities designed to reproduce reliable phenomena. PMID:23494173
Dual-loop model of the human controller
NASA Technical Reports Server (NTRS)
Hess, R. A.
1978-01-01
A dual-loop model of the human controller in single-axis compensatory tracking tasks is introduced. This model possesses an inner-loop closure that involves feeding back that portion of controlled element output rate that is due to control activity. A novel feature of the model is the explicit appearance of the human's internal representation of the manipulator-controlled element dynamics in the inner loop. The sensor inputs to the human controller are assumed to be system error and control force. The former can be sensed via visual, aural, or tactile displays, whereas the latter is assumed to be sensed in kinesthetic fashion. A set of general adaptive characteristics for the model is hypothesized, including a method for selecting simplified internal models of the manipulator-controlled element dynamics. It is demonstrated that the model can produce controller describing functions that closely approximate those measured in four laboratory tracking tasks in which the controlled element dynamics vary considerably in terms of ease of control. An empirically derived expression for the normalized injected error remnant spectrum is introduced.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, Emily K.; Aalseth, Craig E.; Bonicalzi, Ricco
Abstract. Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counters (ULBPC) designs and now operate in PNNL’s shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of OFHC copper components for use in an above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates,more » gas gain, energy resolution, and shielding considerations. These results will be presented along with uncertainty estimates of future absolute gas counting measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, E. K.; Aalseth, C. E.; Bonicalzi, R.
Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., {sup 37}Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counter designs and now operate in PNNL's shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of Oxygen-Free High-Conductivity copper components for use in a shielded above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of backgroundmore » rates, gas gain, and energy resolution. These results will be presented along with a shielding study for the above-ground cave.« less
Lund, Frederike; Schultz, Jobst-Hendrik; Maatouk, Imad; Krautter, Markus; Möltner, Andreas; Werner, Anne; Weyrich, Peter; Jünger, Jana; Nikendei, Christoph
2012-01-01
Background The effectiveness of skills laboratory training is widely recognized. Yet, the transfer of procedural skills acquired in skills laboratories into clinical practice has rarely been investigated. We conducted a prospective, randomised, double-blind, controlled trial to evaluate, if students having trained intravenous (IV) cannulation in a skills laboratory are rated as more professional regarding technical and communication skills compared to students who underwent bedside teaching when assessed objectively by independent video assessors and subjectively by patients. Methodology and Principal Findings 84 volunteer first-year medical students were randomly assigned to one of two groups. Three drop-outs occurred. The intervention group (IG; n = 41) trained IV cannulation in a skills laboratory receiving instruction after Peyton's ‘Four-Step Approach’. The control group (CG; n = 40) received a bedside teaching session with volunteer students acting as patients. Afterwards, performance of IV cannulation of both groups in a clinical setting with students acting as patients was video-recorded. Two independent, blinded video assessors scored students' performance using binary checklists (BC) and the Integrated Procedural Protocol Instrument (IPPI). Patients assessed students' performance with the Communication Assessment Tool (CAT) and a modified IPPI. IG required significantly shorter time needed for the performance on a patient (IG: 595.4 SD(188.1)s; CG: 692.7 SD(247.8)s; 95%CI 23.5 s to 45.1 s; p = 0.049) and completed significantly more single steps of the procedure correctly (IG: 64% SD(14) for BC items; CG: 53% SD(18); 95%CI 10.25% to 11.75%; p = 0.004). IG also scored significantly better on IPPI ratings (median: IG: 3.1; CG: 3.6; p = 0.015;). Rated by patients, students' performance and patient-physician communication did not significantly differ between groups. Conclusions Transfer of IV cannulation-related skills acquired in a skills laboratory is superior to bedside teaching when rated by independent video raters by means of IPPI and BC. It enables students to perform IV cannulation more professionally on volunteer students acting as patients. PMID:22427895
Lin, Guigao; Zhang, Kuo; Zhang, Dong; Han, Yanxi; Xie, Jiehong; Li, Jinming
2017-03-01
The emergence of Zika virus demands accurate laboratory diagnostics. Nucleic acid testing is currently the definitive method for diagnosis of Zika infection. In 2016, an external quality assurance (EQA) for assessing the quality of molecular testing of Zika virus was carried out in China. A single armored RNA encapsulating a 4942-nucleotides (nt) long specific RNA sequence of Zika virus was prepared and used as positive samples. A pre-tested EQA panel, consisting of 4 negative and 6 positive samples with different concentrations of armored RNA, was distributed to 38 laboratories that perform molecular detection of Zika virus. A total of 39 data sets (1 laboratory used two test kits in parallel), produced by using commercial (n=38) or laboratory developed (n=1) quantitative reverse-transcriptase PCR (qRT-PCR) kits, were received. Of these, 35 (89.7%) had correct results for all 10 samples, and 4 (10.3%) reported at least 1 error (11 in total). The testing errors were all false-negatives, highlighting the need of improvements in detecting sensitivity. The EQA reveals that the majority of participating laboratories are proficient in molecular testing of Zika virus. Copyright © 2017 Elsevier B.V. All rights reserved.
Practical biosafety in the tuberculosis laboratory: containment at the source is what truly counts.
van Soolingen, D; Wisselink, H J; Lumb, R; Anthony, R; van der Zanden, A; Gilpin, C
2014-08-01
In industrialised countries, sufficient resources for establishing and maintaining fully equipped biosafety level 3 (BSL-3) laboratories according to international standards are generally available. BSL-3 laboratories are designed to provide several layers of containment to protect the laboratory worker as well as the outside environment and community from risk of exposure in case of local contamination. However, such facilities are scarce in high-burden settings, primarily due to the high financial burden and complexity of the initial construction and/or regular maintenance. Measures to prevent unintended exposure to Mycobacterium tuberculosis during laboratory manipulation of specimens and cultures is the first, and by far the most important, aspect of containment. This paper focuses on the need for risk containment at source. Assuming that in many settings the establishment of BSL-3 laboratories with all the required features is not achievable, this paper also discusses the minimum requirements necessary to mitigate risks associated with particular laboratory procedures. The term 'TB containment laboratory' is used throughout this paper to describe the minimum requirements for a laboratory suitable for high-risk procedures. The TB containment laboratory has many, but not all, of the features of a BSL-3 laboratory.
Shrivastava, Rakesh; Sen, Sourav; Banerji, Debabrata; Praharaj, Ashok K; Chopra, Gurvinder Singh; Gill, Satyajit Singh
2013-01-01
A total of 350 million individuals are affected by chronic hepatitis B virus infection world-wide. Historically, liver biopsy has been instrumental in adequately assessing patients with chronic liver disease. A number of non-invasive models have been studied world-wide. The aim of this study is to assess the utility of non-invasive mathematical models of liver fibrosis in chronic hepatitis B (CHB). Indian patients in a resource limited setting using routinely performed non-invasive laboratory investigations. A cross-sectional study carried out at a tertiary care center. A total of 52 consecutive chronic liver disease patients who underwent percutaneous liver biopsy and 25 healthy controls were enrolled in the study. Routine laboratory investigations included serum aspartate aminotransferase (AST), Alanine aminotransferase (ALT), Gama glutamyl transpeptidase (GGT), total bilirubin, total cholesterol, prothrombin time and platelet count. Three non-invasive models for namely aspartate aminotransferase to platelet ratio index (APRI), Fibrosis 4 (FIB-4) and Forn's index were calculated. Outcomes were compared for the assessment of best predictor of fibrosis by calculating the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of each index. Medcalc online software and by Microsoft Excel Worksheet. Chi-square test was used for significance. P value < 0.05 was taken as significant. While the serum levels of AST, ALT and GGT were significantly higher in patients group as compare with the healthy controls (P < 0.01), the platelet counts were significantly lower in patient group as compared to the control group (P < 0.01). Mean value of all 3 indices were significantly higher in patients group as compare with the controls (P < 0.01). Out of the three indices, APRI index with a NPV of 95% appeared to be a better model for excluding significant liver fibrosis while FIB-4 with a PPV of 61% showed fair correlation with significant fibrosis. Thus, these two non-invasive models for predicting of liver fibrosis, namely APRI and FIB-4, can be utilized in combination as screening tools in monitoring of CHB patients, especially in resource limiting settings.
21 CFR 226.58 - Laboratory controls.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test... establishment of master records containing appropriate specifications and a description of the test procedures... necessary laboratory test procedures to check such specifications. (c) Assays which shall be made of...
Computer-generated reminders and quality of pediatric HIV care in a resource-limited setting.
Were, Martin C; Nyandiko, Winstone M; Huang, Kristin T L; Slaven, James E; Shen, Changyu; Tierney, William M; Vreeman, Rachel C
2013-03-01
To evaluate the impact of clinician-targeted computer-generated reminders on compliance with HIV care guidelines in a resource-limited setting. We conducted this randomized, controlled trial in an HIV referral clinic in Kenya caring for HIV-infected and HIV-exposed children (<14 years of age). For children randomly assigned to the intervention group, printed patient summaries containing computer-generated patient-specific reminders for overdue care recommendations were provided to the clinician at the time of the child's clinic visit. For children in the control group, clinicians received the summaries, but no computer-generated reminders. We compared differences between the intervention and control groups in completion of overdue tasks, including HIV testing, laboratory monitoring, initiating antiretroviral therapy, and making referrals. During the 5-month study period, 1611 patients (49% female, 70% HIV-infected) were eligible to receive at least 1 computer-generated reminder (ie, had an overdue clinical task). We observed a fourfold increase in the completion of overdue clinical tasks when reminders were availed to providers over the course of the study (68% intervention vs 18% control, P < .001). Orders also occurred earlier for the intervention group (77 days, SD 2.4 days) compared with the control group (104 days, SD 1.2 days) (P < .001). Response rates to reminders varied significantly by type of reminder and between clinicians. Clinician-targeted, computer-generated clinical reminders are associated with a significant increase in completion of overdue clinical tasks for HIV-infected and exposed children in a resource-limited setting.
NASA Astrophysics Data System (ADS)
Idehara, H.; Carbon, D. F.
2004-12-01
We present two new, publicly available tools to support the examination and interpretation of spectra. SCAMP is a specialized graphical user interface for MATLAB. It allows researchers to rapidly intercompare sets of observational, theoretical, and/or laboratory spectra. Users have extensive control over the colors and placement of individual spectra, and over spectrum normalization from one spectral region to another. Spectra can be interactively assigned to user-defined groups and the groupings recalled at a later time. The user can measure/record positions and intensities of spectral features, interactively spline-fit spectra, and normalize spectra by fitted splines. User-defined wavelengths can be automatically highlighted in SCAMP plots. The user can save/print annotated graphical output suitable for a scientific notebook depicting the work at any point. The ASP is a WWW portal that provides interactive access to two spectrum data sets: a library of synthetic stellar spectra and a library of laboratory PAH spectra. The synthetic stellar spectra in the ASP are appropriate to the giant branch with an assortment of compositions. Each spectrum spans the full range from 2 to 600 microns at a variety of resolutions. The ASP is designed to allow users to quickly identify individual features at any resolution that arise from any of the included isotopic species. The user may also retrieve the depth of formation of individual features at any resolution. PAH spectra accessible through the ASP are drawn from the extensive library of spectra measured by the NASA Ames Astrochemistry Laboratory. The user may interactively choose any subset of PAHs in the data set, combine them with user-defined weights and temperatures, and view/download the resultant spectrum at any user-defined resolution. This work was funded by the NASA Advanced Supercomputing Division, NASA Ames Research Center.
Wild immunology assessed by multidimensional mass cytometry.
Japp, Alberto Sada; Hoffmann, Kerstin; Schlickeiser, Stephan; Glauben, Rainer; Nikolaou, Christos; Maecker, Holden T; Braun, Julian; Matzmohr, Nadine; Sawitzki, Birgit; Siegmund, Britta; Radbruch, Andreas; Volk, Hans-Dieter; Frentsch, Marco; Kunkel, Desiree; Thiel, Andreas
2017-01-01
A great part of our knowledge on mammalian immunology has been established in laboratory settings. The use of inbred mouse strains enabled controlled studies of immune cell and molecule functions in defined settings. These studies were usually performed in specific-pathogen free (SPF) environments providing standardized conditions. In contrast, mammalians including humans living in their natural habitat are continuously facing pathogen encounters throughout their life. The influences of environmental conditions on the signatures of the immune system and on experimental outcomes are yet not well defined. Thus, the transferability of results obtained in current experimental systems to the physiological human situation has always been a matter of debate. Studies elucidating the diversity of "wild immunology" imprintings in detail and comparing it with those of "clean" lab mice are sparse. Here, we applied multidimensional mass cytometry to dissect phenotypic and functional differences between distinct groups of laboratory and pet shop mice as a source for "wild mice". For this purpose, we developed a 31-antibody panel for murine leukocyte subsets identification and a 35-antibody panel assessing various cytokines. Established murine leukocyte populations were easily identified and diverse immune signatures indicative of numerous pathogen encounters were classified particularly in pet shop mice and to a lesser extent in quarantine and non-SPF mice as compared to SPF mice. In addition, unsupervised analysis identified distinct clusters that associated strongly with the degree of pathogenic priming, including increased frequencies of activated NK cells and antigen-experienced B- and T-cell subsets. Our study unravels the complexity of immune signatures altered under physiological pathogen challenges and highlights the importance of carefully adapting laboratory settings for immunological studies in mice, including drug and therapy testing. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.
HEW to Set Laboratory Safety Standards.
ERIC Educational Resources Information Center
Chemical and Engineering News, 1978
1978-01-01
Describes Department of Health, Education and Welfare (HEW) proposed guidelines for laboratories using chemical carcinogens. The guidelines are designed to provide protection for laboratory workers and their environment from exposure to all types of carcinogenic agents. (GA)
Air Pressure Controlled Mass Measurement System
NASA Astrophysics Data System (ADS)
Zhong, Ruilin; Wang, Jian; Cai, Changqing; Yao, Hong; Ding, Jin'an; Zhang, Yue; Wang, Xiaolei
Mass measurement is influenced by air pressure, temperature, humidity and other facts. In order to reduce the influence, mass laboratory of National Institute of Metrology, China has developed an air pressure controlled mass measurement system. In this system, an automatic mass comparator is installed in an airtight chamber. The Chamber is equipped with a pressure controller and associate valves, thus the air pressure can be changed and stabilized to the pre-set value, the preferred pressure range is from 200 hPa to 1100 hPa. In order to keep the environment inside the chamber stable, the display and control part of the mass comparator are moved outside the chamber, and connected to the mass comparator by feed-throughs. Also a lifting device is designed for this system which can easily lift up the upper part of the chamber, thus weights can be easily put inside the mass comparator. The whole system is put on a marble platform, and the temperature and humidity of the laboratory is very stable. The temperature, humidity, and carbon dioxide content inside the chamber are measured in real time and can be used to get air density. Mass measurement cycle from 1100 hPa to 200 hPa and back to 1100 hPa shows the effective of the system.
NASA Technical Reports Server (NTRS)
1972-01-01
A user's manual is provided for the environmental computer model proposed for the Richmond-Cape Henry Environmental Laboratory (RICHEL) application project for coastal zone land use investigations and marine resources management. The model was developed around the hydrologic cycle and includes two data bases consisting of climate and land use variables. The main program is described, along with control parameters to be set and pertinent subroutines.
Ethanolic carbon-11 chemistry: the introduction of green radiochemistry.
Shao, Xia; Fawaz, Maria V; Jang, Keunsam; Scott, Peter J H
2014-07-01
The principles of green chemistry have been applied to a radiochemistry setting. Eleven carbon-11 labeled radiopharmaceuticals have been prepared using ethanol as the only organic solvent throughout the entire manufacturing process. The removal of all other organic solvents from the process simplifies production and quality control (QC) testing, moving our PET Center towards the first example of a green radiochemistry laboratory. All radiopharmaceutical doses prepared are suitable for clinical use. Copyright © 2014 Elsevier Ltd. All rights reserved.
INRiM Time and Frequency Laboratory: A New Data Management System (DMS)
2010-11-01
protocols defined at international level. The INRIM TFL, at present, is equipped with a set of measuring and control devices (SAD – Sistema di...Proceedings of the 22 th European Frequency and Time Forum (EFTF), 22-25 April 2008, Toulouse, France. [2] G. Vizio, 2000, “ Sistema per l’acquisizione...dei dati del Laboratorio di Tempo e Frequenza,” Manuale Operativo INRIM – 2000. [3] R. Costa, D. Orgiazzi, G. C. Cerretto, and V. Pettiti, 2010
2009-07-11
Mike Suffredini, NASA Manager, International Space Station (ISS) Program, talks with other NASA mission managers in from Firing Room Four of the Launch Control Center at NASA's Kennedy Space Center in Cape Canaveral, Florida, Sunday, July 12, 2009. The space shuttle Endeavour is set to launch at 7:13p.m. EDT with the crew of STS-127 and start a 16-day mission that will feature five spacewalks and complete construction of the Japan Aerospace Exploration Agency's Kibo laboratory. Photo Credit: (NASA/Bill Ingalls)
Hypercalcemia with renal failure.
Bhavani, Nisha; Praveen, Valiyaparambil Pavithran; Jayakumar, Rohinivilasam Vasukutty; Nair, Vasantha; Muraleedharan, Mangath; Kuma, Harish; Unnikrishnan, Ambika Gopalakrishnan; Menon, Vadayath Usha
2012-06-01
We report a cse of nephrocalcinosis with renal failure which on evaluation was found to have hypercalcemia. Further investigations showed an inappropriately normal intact parathormone (iPTH) and 1,25 dihydroxy-vitamin D level in the setting of renal failure. Probing for a cause of non-PTH mediated hypercalcemia led to the diagnosis of sarcoidosis. Treatment with glucocorticoids could partially reverse the renal failure and control the hypercalcemia. This case illustrates the importance of careful interpretation of laboratory parameters especially levels of iPTH and vitamin D metabolites in renal failure.
Application of Ada (Trade Name) Higher Order Language to Guidance and Control
1986-05-01
name "DoD-0"). The name Ada honors the mathematician of the 19th century who, as colleague to Charles Babbage , developed an instruction set for the as...Avenue St Charles , MO 63301 USA SPEAKERS Mr R.E.Bolz 6751 South Dahlia Court Modem Prograimning Languages Littleton, CO 80122 USA Dr O.Roubine...WHITTREDGE, R. S. PAA : C/( Charles Stark Draper Laboratory, Inc., Cambridge, MA) CORP: Draper ( Charles Stark) Lab., Inc., Cambridge, Mass. IN
Virtually the ultimate research lab.
Kulik, Alexander
2018-04-26
Virtual reality (VR) can serve as a viable platform for psychological research. The real world with many uncontrolled variables can be masked to immerse participants in complex interactive environments that are under full experimental control. However, as any other laboratory setting, these simulations are not perceived equally to reality and they also afford different behaviour. We need a better understanding of these differences, which are often related to parameters of the technical setup, to support valid interpretations of experimental results. © 2018 The British Psychological Society.
Crewmembers in the spacelab with Generic Bioprocessing Apparatus, Rack #10.
1992-07-09
STS050-254-007 (25 June-9 July 1992) --- Lawrence J. DeLucas, payload specialist, handles a Protein Crystal Growth (PCG) sample at the multipurpose glovebox aboard the Earth-orbiting Space Shuttle Columbia. Astronaut Bonnie J. Dunbar, payload commander, communicates with ground controllers about the Solid Surface Combustion Experiment (SSCE), one of the United States Microgravity Laboratory 1’s (USML-1) three experiments on Rack 10. Five other crew members joined the pair for a record-setting 14-days of scientific data gathering.
Optimization Strategies for Sensor and Actuator Placement
NASA Technical Reports Server (NTRS)
Padula, Sharon L.; Kincaid, Rex K.
1999-01-01
This paper provides a survey of actuator and sensor placement problems from a wide range of engineering disciplines and a variety of applications. Combinatorial optimization methods are recommended as a means for identifying sets of actuators and sensors that maximize performance. Several sample applications from NASA Langley Research Center, such as active structural acoustic control, are covered in detail. Laboratory and flight tests of these applications indicate that actuator and sensor placement methods are effective and important. Lessons learned in solving these optimization problems can guide future research.
CA6-02: Collaborative Goal Setting and HbA1c Control Among Patients With Diabetes
Lafata, Jennifer Elston; Dobie, Elizabeth; Morris, Heather; Heisler, Michele; Werner, Rachel; Divine, George; Thomas, Abraham
2012-01-01
Background/Aims Helping patients set and follow up on goals may be an effective way to help patients improve their confidence (self-efficacy) and commitment to improve diabetes self- management. We evaluate associations among patient-reported use of collaborative goal setting with clinicians, patient-reported self-efficacy, and clinical control (measured by HbA1c) among patients with diabetes. Methods A cohort of insured patients aged 18+ years with diabetes who initiated oral mono-therapy between 2000–2005 was surveyed in 2008. The survey included the 3 collaborative goal-setting items from the Patient Assessment of Chronic Illness Care (PACIC), a 4-item measure of self-efficacy, measures of socio-demographics, age of diabetes onset, and height/weight. Survey data were joined with automated laboratory and encounter data for the 12 months prior to and following survey administration. A structural equation model (SEM), using path analysis and adjusting for baseline patient characteristics (including HbA1c and diabetes-related co-morbidities and complications), was fit to investigate relationships among collaborative goal setting, self-efficacy and HbA1c control. Results Completed surveys were available for 1070 patients (n=956 mail and n=114 telephone; 77% response rate). Survey respondents were on average 68 years, half were female, 60% white, 31% black, and 57% reported low self-efficacy. On average, patients reported engaging in collaborative goal setting with their clinicians ‘sometimes’ (mean = 3.1, range 1 [never]-5 [always]). At baseline, mean HbA1c was 7.2%, with 22% =8%. Results from the SEM did not support a direct relationship between the collaborative goal setting factor (Cronbach Alpha=0.83) and HbA1c control, but did support an indirect relationship (asymmetric distribution of products 95% CI = −0.02, −0.002) with increases in collaborative goal setting positively associated with a greater likelihood of average or high self-efficacy (beta, p<0.01), and average or high self-efficacy associated with lower follow-up HbA1cs level (-beta, p<0.01). These relationships persisted after controlling for baseline HbA1c and other patient characteristics. Discussion While collaborative goal setting between patients with diabetes and their clinicians is not directly associated with better clinical control, it is associated with improved self-efficacy, which in turn, is associated with improved clinical control.
Potential effects of vinasse as a soil amendment to control runoff and soil loss
NASA Astrophysics Data System (ADS)
Hazbavi, Z.; Sadeghi, S. H. R.
2016-02-01
Application of organic materials are well known as environmental practices in soil restoration, preserving soil organic matter and recovering degraded soils of arid and semiarid lands. Therefore, the present research focused on evaluating the effectiveness of vinasse, a byproduct mainly of the sugar-ethanol industry, on soil conservation under simulated rainfall. Vinasse can be recycled as a soil amendment due to its organic matter content. Accordingly, the laboratory experiments were conducted by using 0.25 m2 experimental plots at 20 % slope and rainfall intensity of 72 mm h-1 with 0.5 h duration. The effect of vinasse was investigated on runoff and soil loss control. Experiments were set up as a control (with no amendment) and three treated plots with doses of 0.5, 1, and 1.5 L m-2 of vinasse subjected to simulated rainfall. Laboratory results indicated that vinasse at different levels could not significantly (P > 0.05) decrease the runoff amount and soil loss rate in the study plots compared to untreated plots. The average amounts of minimum runoff volume and soil loss were about 3985 mL and 46 g for the study plot at a 1 L m-2 level of vinasse application.
40 CFR 262.102 - What special definitions are included in this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Laboratories XL Project-Laboratory Environmental Management Standard § 262.102 What special definitions are... Laboratory Waste means a laboratory waste, defined in the Environmental Management Plan as posing significant... Management Plan (EMP) means a written program developed and implemented by the university which sets forth...
Challenges of measles and rubella laboratory diagnostic in the era of elimination.
Hübschen, J M; Bork, S M; Brown, K E; Mankertz, A; Santibanez, S; Ben Mamou, M; Mulders, M N; Muller, C P
2017-08-01
The Member States of the WHO European Region adopted the goal of measles and rubella elimination more than 10 years ago, but so far only 21 of 53 countries have reached this target. Laboratory investigation of suspected cases is essential to support disease elimination efforts. Therefore, WHO maintains a network of accredited laboratories providing high-quality testing. Laboratory investigation heavily relies on specific IgM serology and increasingly on virus detection by reverse transcription (RT)-PCR, but other methods such as IgG avidity testing and genetic characterization of virus strains have gained in importance. In elimination settings, often few samples from suspected cases are available for testing, but testing proficiency must be maintained. The predictive value of an IgM-positive result decreases and other rash-fever disease aetiologies become more important. In addition, cases with a rash after measles/rubella vaccination or with mild disease after waning of vaccine-induced antibodies are seen more often. Thus, it is necessary to perform comprehensive and potentially time-consuming and costly investigations of every suspected case using quality-controlled laboratory methods. At the same time rapid feedback to public health officers is required for timely interventions. The introduction of new laboratory methods for comprehensive case investigations requires training of staff under the supervision of WHO-accredited reference laboratories and the definition of appropriate test algorithms. Clinical, laboratory, and epidemiological data are essential for final case classification and investigation of chains of transmission in the endgame of measles and rubella elimination. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. All rights reserved.
The Empower project - a new way of assessing and monitoring test comparability and stability.
De Grande, Linde A C; Goossens, Kenneth; Van Uytfanghe, Katleen; Stöckl, Dietmar; Thienpont, Linda M
2015-07-01
Manufacturers and laboratories might benefit from using a modern integrated tool for quality management/assurance. The tool should not be confounded by commutability issues and focus on the intrinsic analytical quality and comparability of assays as performed in routine laboratories. In addition, it should enable monitoring of long-term stability of performance, with the possibility to quasi "real-time" remedial action. Therefore, we developed the "Empower" project. The project comprises four pillars: (i) master comparisons with panels of frozen single-donation samples, (ii) monitoring of patient percentiles and (iii) internal quality control data, and (iv) conceptual and statistical education about analytical quality. In the pillars described here (i and ii), state-of-the-art as well as biologically derived specifications are used. In the 2014 master comparisons survey, 125 laboratories forming 8 peer groups participated. It showed not only good intrinsic analytical quality of assays but also assay biases/non-comparability. Although laboratory performance was mostly satisfactory, sometimes huge between-laboratory differences were observed. In patient percentile monitoring, currently, 100 laboratories participate with 182 devices. Particularly, laboratories with a high daily throughput and low patient population variation show a stable moving median in time with good between-instrument concordance. Shifts/drifts due to lot changes are sometimes revealed. There is evidence that outpatient medians mirror the calibration set-points shown in the master comparisons. The Empower project gives manufacturers and laboratories a realistic view on assay quality/comparability as well as stability of performance and/or the reasons for increased variation. Therefore, it is a modern tool for quality management/assurance toward improved patient care.
Weykamp, Cas; Siebelder, Carla
2017-11-01
HbA1c is a key parameter in diabetes management. For years the test has been used exclusively for monitoring of long-term diabetic control. However, due to improvement of the performance, HbA1c is considered more and more for diagnosis and screening. With this new application, quality demands further increase. A task force of the International Federation of Clinical Chemistry and Laboratory Medicine developed a model to set and evaluate quality targets for HbA1c. The model is based on the concept of total error and takes into account the major sources of analytical errors in the medical laboratory: bias and imprecision. Performance criteria are derived from sigma-metrics and biological variation. This review shows 2 examples of the application of the model: at the level of single laboratories, and at the level of a group of laboratories. In the first example data of 125 individual laboratories of a recent external quality assessment program in the Netherlands are evaluated. Differences between laboratories as well as their relation to method principles are shown. The second example uses recent and 3-year-old data of the proficiency test of the College of American Pathologists. The differences in performance between 26 manufacturer-related groups of laboratories are shown. Over time these differences are quite consistent although some manufacturers improved substantially either by better standardization or by replacing a test. The IFCC model serves all who are involved in HbA1c testing in the ongoing process of better performance and better patient care.
Code of Federal Regulations, 2010 CFR
2010-04-01
... laboratory operations associated with the production and process control system? 111.110 Section 111.110 Food... OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control... production and process control system? Quality control operations for laboratory operations associated with...
MSL EDL Entry Guidance using the Entry Terminal Point Controller
NASA Technical Reports Server (NTRS)
2006-01-01
The Mars Science Laboratory will be the first Mars mission to attempt a guided entry with the objective of safely delivering the entry vehicle to a survivable parachute deploy state within 10 km of the pre-designated landing site. The Entry Terminal Point Controller guidance algorithm is derived from the final phase Apollo Command Module guidance and, like Apollo, modulates the bank angle to control range based on deviations in range, altitude rate, and drag acceleration from a reference trajectory. For application to Mars landers which must make use of the tenuous Martian atmosphere, it is critical to balance the lift of the vehicle to minimize the range while still ensuring a safe deploy altitude. An overview of the process to generate optimized guidance settings is presented, discussing improvements made over the last four years. Performance tradeoffs between ellipse size and deploy altitude will be presented, along with imposed constraints of entry acceleration and heating. Performance sensitivities to the bank reversal deadbands, heading alignment, attitude initialization error, and atmospheric delivery errors are presented. Guidance settings for contingency operations, such as those appropriate for severe dust storm scenarios, are evaluated.
2014-01-01
We present primary results from the Sequencing Quality Control (SEQC) project, coordinated by the United States Food and Drug Administration. Examining Illumina HiSeq, Life Technologies SOLiD and Roche 454 platforms at multiple laboratory sites using reference RNA samples with built-in controls, we assess RNA sequencing (RNA-seq) performance for junction discovery and differential expression profiling and compare it to microarray and quantitative PCR (qPCR) data using complementary metrics. At all sequencing depths, we discover unannotated exon-exon junctions, with >80% validated by qPCR. We find that measurements of relative expression are accurate and reproducible across sites and platforms if specific filters are used. In contrast, RNA-seq and microarrays do not provide accurate absolute measurements, and gene-specific biases are observed, for these and qPCR. Measurement performance depends on the platform and data analysis pipeline, and variation is large for transcript-level profiling. The complete SEQC data sets, comprising >100 billion reads (10Tb), provide unique resources for evaluating RNA-seq analyses for clinical and regulatory settings. PMID:25150838
NASA Technical Reports Server (NTRS)
Fialho, Ian J.; Thampi, Sreekumar
2000-01-01
A primary mission of the International Space Station (ISS) is to provide a premier microgravity laboratory environment for conducting acceleration sensitive scientific research. In order to accomplish this goal, vibroacoustic disturbances caused by station activities that occur during the microgravity mode of operation, must be controlled. In addition to source isolation and other passive isolation methods, the ISS uses active isolation at the receiver, through the use of an Active Rack Isolation System (ARIS), as part of its overall vibration isolation strategy. A schematic diagram of a typical ARIS payload rack is shown. The ARIS isolation control system senses rack acceleration via three triaxial accelerometer heads and uses eight pushrod actuators to perform active vibration attenuation. Position sensors housed in the actuator assembly are used to sense the relative position between the rack and the station. Electrical power, data and other essential resources are routed through a set of umbilicals that interface with a passthrough panel at the bottom of the rack. A representative umbilical set is shown.
Guidelines on Good Clinical Laboratory Practice
Ezzelle, J.; Rodriguez-Chavez, I. R.; Darden, J. M.; Stirewalt, M.; Kunwar, N.; Hitchcock, R.; Walter, T.; D’Souza, M. P.
2008-01-01
A set of Good Clinical Laboratory Practice (GCLP) standards that embraces both the research and clinical aspects of GLP were developed utilizing a variety of collected regulatory and guidance material. We describe eleven core elements that constitute the GCLP standards with the objective of filling a gap for laboratory guidance, based on IND sponsor requirements, for conducting laboratory testing using specimens from human clinical trials. These GCLP standards provide guidance on implementing GLP requirements that are critical for laboratory operations, such as performance of protocol-mandated safety assays, peripheral blood mononuclear cell processing and immunological or endpoint assays from biological interventions on IND-registered clinical trials. The expectation is that compliance with the GCLP standards, monitored annually by external audits, will allow research and development laboratories to maintain data integrity and to provide immunogenicity, safety, and product efficacy data that is repeatable, reliable, auditable and that can be easily reconstructed in a research setting. PMID:18037599
A quality management systems approach for CD4 testing in resource-poor settings.
Westerman, Larry E; Kohatsu, Luciana; Ortiz, Astrid; McClain, Bernice; Kaplan, Jonathan; Spira, Thomas; Marston, Barbara; Jani, Ilesh V; Nkengasong, John; Parsons, Linda M
2010-10-01
Quality assurance (QA) is a systematic process to monitor and improve clinical laboratory practices. The fundamental components of a laboratory QA program include providing a functional and safe laboratory environment, trained and competent personnel, maintained equipment, adequate supplies and reagents, testing of appropriate specimens, internal monitoring of quality, accurate reporting, and external quality assessments. These components are necessary to provide accurate and precise CD4 T-cell counts, an essential test to evaluate start of and monitor effectiveness of antiretroviral therapy for HIV-infected patients. In recent years, CD4 testing has expanded dramatically in resource-limited settings. Information on a CD4 QA program as described in this article will provide guidelines not only for clinical laboratory staff but also for managers of programs responsible for supporting CD4 testing. All agencies involved in implementing CD4 testing must understand the needs of the laboratory and provide advocacy, guidance, and financial support to established CD4 testing sites and programs. This article describes and explains the procedures that must be put in place to provide reliable CD4 determinations in a variety of settings.
A novel Python program for implementation of quality control in the ELISA.
Wetzel, Hanna N; Cohen, Cinder; Norman, Andrew B; Webster, Rose P
2017-09-01
The use of semi-quantitative assays such as the enzyme-linked immunosorbent assay (ELISA) requires stringent quality control of the data. However, such quality control is often lacking in academic settings due to unavailability of software and knowledge. Therefore, our aim was to develop methods to easily implement Levey-Jennings quality control methods. For this purpose, we created a program written in Python (a programming language with an open-source license) and tested it using a training set of ELISA standard curves quantifying the Fab fragment of an anti-cocaine monoclonal antibody in mouse blood. A colorimetric ELISA was developed using a goat anti-human anti-Fab capture method. Mouse blood samples spiked with the Fab fragment were tested against a standard curve of known concentrations of Fab fragment in buffer over a period of 133days stored at 4°C to assess stability of the Fab fragment and to generate a test dataset to assess the program. All standard curves were analyzed using our program to batch process the data and to generate Levey-Jennings control charts and statistics regarding the datasets. The program was able to identify values outside of two standard deviations, and this identification of outliers was consistent with the results of a two-way ANOVA. This program is freely available, which will help laboratories implement quality control methods, thus improving reproducibility within and between labs. We report here successful testing of the program with our training set and development of a method for quantification of the Fab fragment in mouse blood. Copyright © 2017 Elsevier B.V. All rights reserved.
2012-01-01
Background Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Methods Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs’ request forms. Results Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). Conclusions The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the prescriptive compliance of most of the GPs involved. The presence of the clinical pathologist is seen as an added value. PMID:22759353
Baricchi, Roberto; Zini, Michele; Nibali, Maria Grazia; Vezzosi, Walter; Insegnante, Vincenzo; Manfuso, Clotilde; Polese, Alessandra; Costoli, Valmer; Spelti, Antonio; Formisano, Debora; Orlandini, Danilo; Nicolini, Fausto; Poli, Antonio
2012-07-03
Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs' request forms. Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the prescriptive compliance of most of the GPs involved. The presence of the clinical pathologist is seen as an added value.
Verification of STS markers for leaf rust resistance genes of wheat by seven European laboratories.
Błaszczyk, Lidia; Chełkowski, Jerzy; Korzun, Victor; Kraic, Jan; Ordon, Frank; Ovesná, Jaroslava; Purnhauser, Laszlo; Tar, Melinda; Vida, Gyula
2004-01-01
A set of Thatcher near-isogenic lines and two breeding lines were used to examine sequence tagged site (STS) markers linked to leaf rust resistance genes Lr9, Lr10, Lr19, Lr24, Lr28, Lr29, Lr35, and a simple sequenced repeat (SSR) marker for Lr39. The selected STS markers for resistance genes Lr9, Lr10, Lr19, Lr24 and Lr28 were identified in seven accessions by seven European laboratories. Near-isogenic lines of the spring wheat Thatcher were used as positive controls. Markers for resistance genes Lr9, Lr10, Lr19, Lr24 were identified in all seven laboratories as amplification products of 1100 bp, 310 bp, 130 bp and 310 bp, respectively. The STS markers linked to resistance genes Lr9, Lr10, Lr19, Lr24, Lr29, Lr35 and the SSR marker for Lr39 were robust and highly specific for these genes and will be useful in marker-assisted selection in wheat. However, the amplification product of 378 bp that corresponded with resistance gene Lr28 was detected in all accessions including genotypes lacking this gene in all seven laboratories. This marker needs to be improved.
Ferrer, Rebecca A; Padgett, Lynne; Ellis, Erin M
2016-08-01
Although laboratory-based research on emotion and decision-making holds the distinct advantage of rigorous experimental control conditions that allow causal inferences, the question of how findings in a laboratory generalize to real-world settings remains. Identifying ecologically valid, real-world opportunities to extend laboratory findings is a valuable means of advancing this field. Palliative care-or care intended to provide relief from serious illness and aging-related complications during treatment or at the end of life-provides a particularly rich opportunity for such work. Here, we present an overview of palliative care, summarize existing research on emotion and palliative care decision-making, highlight challenges associated with conducting such research, outline examples of collaborative projects leveraging palliative care as a context for generating fundamental knowledge about emotion and decision-making, and describe the resources and collaborations necessary to conduct this type of research. In sum, palliative care holds unique promise as an emotionally laden context in which to answer fundamental questions about emotion and decision-making that extends our theoretical understanding of the role of emotion in high-stakes decision-making while simultaneously generating knowledge that can improve palliative care implementation. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
NASA Technical Reports Server (NTRS)
Eaton, L. R.; Greco, E. V.
1973-01-01
The experiment program definition and preliminary laboratory concept studies on the zero G cloud physics laboratory are reported. This program involves the definition and development of an atmospheric cloud physics laboratory and the selection and delineations of a set of candidate experiments that must utilize the unique environment of zero gravity or near zero gravity.
Potential metabolite markers of schizophrenia.
Yang, J; Chen, T; Sun, L; Zhao, Z; Qi, X; Zhou, K; Cao, Y; Wang, X; Qiu, Y; Su, M; Zhao, A; Wang, P; Yang, P; Wu, J; Feng, G; He, L; Jia, W; Wan, C
2013-01-01
Schizophrenia is a severe mental disorder that affects 0.5-1% of the population worldwide. Current diagnostic methods are based on psychiatric interviews, which are subjective in nature. The lack of disease biomarkers to support objective laboratory tests has been a long-standing bottleneck in the clinical diagnosis and evaluation of schizophrenia. Here we report a global metabolic profiling study involving 112 schizophrenic patients and 110 healthy subjects, who were divided into a training set and a test set, designed to identify metabolite markers. A panel of serum markers consisting of glycerate, eicosenoic acid, β-hydroxybutyrate, pyruvate and cystine was identified as an effective diagnostic tool, achieving an area under the receiver operating characteristic curve (AUC) of 0.945 in the training samples (62 patients and 62 controls) and 0.895 in the test samples (50 patients and 48 controls). Furthermore, a composite panel by the addition of urine β-hydroxybutyrate to the serum panel achieved a more satisfactory accuracy, which reached an AUC of 1 in both the training set and the test set. Multiple fatty acids and ketone bodies were found significantly (P<0.01) elevated in both the serum and urine of patients, suggesting an upregulated fatty acid catabolism, presumably resulting from an insufficiency of glucose supply in the brains of schizophrenia patients.
Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection.
Carta, R; Tortora, G; Thoné, J; Lenaerts, B; Valdastri, P; Menciassi, A; Dario, P; Puers, R
2009-12-15
This paper describes the integration of an active locomotion module in a wirelessly powered endoscopic capsule. The device is a submersible capsule optimized to operate in a fluid environment in a liquid-distended stomach. A 3D inductive link is used to supply up to 400mW to the embedded electronics and a set of 4 radio-controlled motor propellers. The design takes advantage of a ferrite-core in the receiving coil-set. This approach significantly improves the coupling with the external field source with respect to earlier work by the group. It doubles the power that can be received with a coreless coil-set under identical external conditions. The upper limit of the received power was achieved complying with the strict regulations for safe exposure of biological tissue to variable magnetic fields. The wireless transferred power was proven to be sufficient to achieve the speed of 7cm/s in any directions. An optimized locomotion strategy was defined which limits the power consumption by running only 2 motors at a time. A user interface and a joystick controller allow to fully drive the capsule in an intuitive manner. The device functionalities were successfully tested in a dry and a wet environment in a laboratory set-up.
Flexible distributed architecture for semiconductor process control and experimentation
NASA Astrophysics Data System (ADS)
Gower, Aaron E.; Boning, Duane S.; McIlrath, Michael B.
1997-01-01
Semiconductor fabrication requires an increasingly expensive and integrated set of tightly controlled processes, driving the need for a fabrication facility with fully computerized, networked processing equipment. We describe an integrated, open system architecture enabling distributed experimentation and process control for plasma etching. The system was developed at MIT's Microsystems Technology Laboratories and employs in-situ CCD interferometry based analysis in the sensor-feedback control of an Applied Materials Precision 5000 Plasma Etcher (AME5000). Our system supports accelerated, advanced research involving feedback control algorithms, and includes a distributed interface that utilizes the internet to make these fabrication capabilities available to remote users. The system architecture is both distributed and modular: specific implementation of any one task does not restrict the implementation of another. The low level architectural components include a host controller that communicates with the AME5000 equipment via SECS-II, and a host controller for the acquisition and analysis of the CCD sensor images. A cell controller (CC) manages communications between these equipment and sensor controllers. The CC is also responsible for process control decisions; algorithmic controllers may be integrated locally or via remote communications. Finally, a system server images connections from internet/intranet (web) based clients and uses a direct link with the CC to access the system. Each component communicates via a predefined set of TCP/IP socket based messages. This flexible architecture makes integration easier and more robust, and enables separate software components to run on the same or different computers independent of hardware or software platform.
The Efficacy of the LearningRx Cognitive Training Program: Modality and Transfer Effects
ERIC Educational Resources Information Center
Hill, Oliver W.; Serpell, Zewelanji; Faison, M. Omar
2016-01-01
This article describes two studies testing the efficacy of a commercial one-on-one cognitive training program (LearningRx) and its computer-based version (Brainskills) in laboratory and school settings. Study 1 tested Brainskills in a laboratory setting with 322 middle school students. Paired "t"-tests revealed significant gains on all…
Parallels, How Many? Geometry Module for Use in a Mathematics Laboratory Setting.
ERIC Educational Resources Information Center
Brotherton, Sheila; And Others
This is one of a series of geometry modules developed for use by secondary students in a laboratory setting. This module was conceived as an alternative approach to the usual practice of giving Euclid's parallel postulate and then mentioning that alternate postulates would lead to an alternate geometry or geometries. Instead, the student is led…
Kuipers sets up the CSA-CP in the U.S. Laboratory
2012-01-26
ISS030-E-156455 (26 Jan. 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, sets up the Compound Specific Analyzer - Combustion Products (CSA-CP) in the Destiny laboratory of the International Space Station. The purpose of the analyzer is to measure the concentrations of carbon monoxide, hydrogen cyanide, hydrogen chloride and oxygen.
Multi-linear model set design based on the nonlinearity measure and H-gap metric.
Shaghaghi, Davood; Fatehi, Alireza; Khaki-Sedigh, Ali
2017-05-01
This paper proposes a model bank selection method for a large class of nonlinear systems with wide operating ranges. In particular, nonlinearity measure and H-gap metric are used to provide an effective algorithm to design a model bank for the system. Then, the proposed model bank is accompanied with model predictive controllers to design a high performance advanced process controller. The advantage of this method is the reduction of excessive switch between models and also decrement of the computational complexity in the controller bank that can lead to performance improvement of the control system. The effectiveness of the method is verified by simulations as well as experimental studies on a pH neutralization laboratory apparatus which confirms the efficiency of the proposed algorithm. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Olympus receiver evaluation and phase noise measurements
NASA Technical Reports Server (NTRS)
Campbell, Richard L.; Wang, Huailiang; Sweeney, Dennis
1990-01-01
A set of measurements performed by the Michigan Tech Sensing and Signal Processing Group on the analog receiver built by the Virginia Polytechnic Institute (VPI) and the Jet Propulsion Laboratory (JPL) for propagation measurements using the Olympus Satellite is described. Measurements of local oscillator (LO) phase noise were performed for all of the LOs supplied by JPL. In order to obtain the most useful set of measurements, LO phase noise measurements were made using the complete VPI receiver front end. This set of measurements demonstrates the performance of the receiver from the Radio Frequency (RF) input through the high Intermediate Frequency (IF) output. Three different measurements were made: LO phase noise with DC on the voltage controlled crystal oscillator (VCXO) port; LO phase noise with the 11.381 GHz LO locked to the reference signal generator; and a reference measurement with the JPL LOs out of the system.
The Effect of Automated Alerts on Provider Ordering Behavior in an Outpatient Setting
Steele, Andrew W; Eisert, Sheri; Witter, Joel; Lyons, Pat; Jones, Michael A; Gabow, Patricia; Ortiz, Eduardo
2005-01-01
Background Computerized order entry systems have the potential to prevent medication errors and decrease adverse drug events with the use of clinical-decision support systems presenting alerts to providers. Despite the large volume of medications prescribed in the outpatient setting, few studies have assessed the impact of automated alerts on medication errors related to drug–laboratory interactions in an outpatient primary-care setting. Methods and Findings A primary-care clinic in an integrated safety net institution was the setting for the study. In collaboration with commercial information technology vendors, rules were developed to address a set of drug–laboratory interactions. All patients seen in the clinic during the study period were eligible for the intervention. As providers ordered medications on a computer, an alert was displayed if a relevant drug–laboratory interaction existed. Comparisons were made between baseline and postintervention time periods. Provider ordering behavior was monitored focusing on the number of medication orders not completed and the number of rule-associated laboratory test orders initiated after alert display. Adverse drug events were assessed by doing a random sample of chart reviews using the Naranjo scoring scale. The rule processed 16,291 times during the study period on all possible medication orders: 7,017 during the pre-intervention period and 9,274 during the postintervention period. During the postintervention period, an alert was displayed for 11.8% (1,093 out of 9,274) of the times the rule processed, with 5.6% for only “missing laboratory values,” 6.0% for only “abnormal laboratory values,” and 0.2% for both types of alerts. Focusing on 18 high-volume and high-risk medications revealed a significant increase in the percentage of time the provider stopped the ordering process and did not complete the medication order when an alert for an abnormal rule-associated laboratory result was displayed (5.6% vs. 10.9%, p = 0.03, Generalized Estimating Equations test). The provider also increased ordering of the rule-associated laboratory test when an alert was displayed (39% at baseline vs. 51% during post intervention, p < 0.001). There was a non-statistically significant difference towards less “definite” or “probable” adverse drug events defined by Naranjo scoring (10.3% at baseline vs. 4.3% during postintervention, p = 0.23). Conclusion Providers will adhere to alerts and will use this information to improve patient care. Specifically, in response to drug–laboratory interaction alerts, providers will significantly increase the ordering of appropriate laboratory tests. There may be a concomitant change in adverse drug events that would require a larger study to confirm. Implementation of rules technology to prevent medication errors could be an effective tool for reducing medication errors in an outpatient setting. PMID:16128621
Test set readings predict clinical performance to a limited extent: preliminary findings
NASA Astrophysics Data System (ADS)
Soh, BaoLin P.; Lee, Warwick M.; Kench, Peter L.; Reed, Warren M.; McEntee, Mark F.; Brennan, Patrick C.
2013-03-01
Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p < 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.
An open-source laser electronics suite
NASA Astrophysics Data System (ADS)
Pisenti, Neal C.; Reschovsky, Benjamin J.; Barker, Daniel S.; Restelli, Alessandro; Campbell, Gretchen K.
2016-05-01
We present an integrated set of open-source electronics for controlling external-cavity diode lasers and other instruments in the laboratory. The complete package includes a low-noise circuit for driving high-voltage piezoelectric actuators, an ultra-stable current controller based on the design of, and a high-performance, multi-channel temperature controller capable of driving thermo-electric coolers or resistive heaters. Each circuit (with the exception of the temperature controller) is designed to fit in a Eurocard rack equipped with a low-noise linear power supply capable of driving up to 5 A at +/- 15 V. A custom backplane allows signals to be shared between modules, and a digital communication bus makes the entire rack addressable by external control software over TCP/IP. The modular architecture makes it easy for additional circuits to be designed and integrated with existing electronics, providing a low-cost, customizable alternative to commercial systems without sacrificing performance.
Theme: Land Laboratories--Urban Settings, Liability, Natural Resources Labs.
ERIC Educational Resources Information Center
Whaley, David, Ed.; And Others
1994-01-01
Includes "With a Little Imagination"; "From Fallow to Fertile"; "Operating a School Enterprise in Agriculture"; "Using a Nontraditional Greenhouse to Enhance Lab Instruction"; "Risk Management for Liability in Operating Land Laboratories"; "Working Land and Water Laboratory for Natural…
Revealing all: misleading self-disclosure rates in laboratory-based online research.
Callaghan, Diana E; Graff, Martin G; Davies, Joanne
2013-09-01
Laboratory-based experiments in online self-disclosure research may be inadvertently compromising the accuracy of research findings by influencing some of the factors known to affect self-disclosure behavior. Disclosure-orientated interviews conducted with 42 participants in the laboratory and in nonlaboratory settings revealed significantly greater breadth of self-disclosure in laboratory interviews, with message length and intimacy of content also strongly related. These findings suggest that a contrived online setting with a researcher presence may stimulate motivation for greater self-disclosure than would occur naturally in an online environment of an individual's choice. The implications of these findings are that researchers should consider the importance of experimental context and motivation in self-disclosure research.
Byrne, Karen M; Levy, Kimberly Y; Reese, Erika M
2016-05-01
Maintaining an in-compliance clinical laboratory takes continuous awareness and review of standards, regulations, and best practices. A strong quality assurance program and well informed leaders who maintain professional networks can aid in this necessary task. This article will discuss a process that laboratories can follow to interpret, understand, and comply with the rules and standards set by laboratory accreditation bodies. Published by Oxford University Press on behalf American Society for Clinical Pathology, 2016. This work is written by US Government employees and is in the public domain in the United States.
Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A
2013-03-01
Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity-driven micro-drip infusion sets under wide-open flow conditions revealed that infusion rate (drug and/or volume delivery) can vary widely depending on extrinsic factors including catheter size, fluid column height, and carrier flow. The variable resistance implies nonlaminar flow in the micro-drip model that cannot be easily predicted mathematically. These findings support the use of mechanical pumps instead of gravity-driven micro-drips to enhance the precision and safety of IV infusions, especially for vasoactive drugs.
Ottria, G; Dallera, M; Aresu, O; Manniello, M A; Parodi, B; Spagnolo, A M; Cristina, M L
2010-12-01
Recent discoveries in cell therapy research present new opportunities for cellular products to be used to treat severe, and as yet incurable, diseases. It is therefore essential to implement a quality control programme in order to ensure that safe cells and tissues are provided. In a preliminary phase of the setting up of a the cellfactory, monitoring was carried out monthly over a 6-month period in one out of three cell therapy laboratories and filter rooms in order to evaluate the microbial contamination of air and surfaces and the presence of airborne particulates. The mean total bacterial and fungal loads measured in the air in the centre of the filter room were 20.7 +/1 28.9 colony-forming units (cfu)/m3 and 9.2 +/- 15.4 cfu/m3, respectively, and 5.2 +/- 4.1 cfu/m3 and 6.8 +/- 13.4 cfu/m3, respectively, in the laboratory. The mean fungal load values recorded on the surfaces sampled in the laboratory were in 6 out of 18 cases higher than the reference values (5 cfu/plate). As to the results of particulate monitoring, with regard to the 0.5 microm particles, about 83% of the samples revealed values below the limit of 350.000 particles per cubic metre. In this set-up phase, monitoring was able to pick out structural and organisational flaws acceptable in a laboratory compliant with Good Manufacturing Practices class C (Annex 1), but not in a class B facility. Thanks to this preliminary monitoring phase, and by correcting these flaws, the clean room facility could achieve compliance to class B.
Russell, Jamie L; Lyn, Heidi; Schaeffer, Jennifer A; Hopkins, William D
2011-11-01
The cultural intelligence hypothesis (CIH) claims that humans' advanced cognition is a direct result of human culture and that children are uniquely specialized to absorb and utilize this cultural experience (Tomasello, 2000). Comparative data demonstrating that 2.5-year-old human children outperform apes on measures of social cognition but not on measures of physical cognition support this claim (Herrmann et al., 2007). However, the previous study failed to control for rearing when comparing these two species. Specifically, the human children were raised in a human culture whereas the apes were raised in standard sanctuary settings. To further explore the CIH, here we compared the performance on multiple measures of social and physical cognition in a group of standard reared apes raised in conditions typical of zoo and biomedical laboratory settings to that of apes reared in an enculturated socio-communicatively rich environment. Overall, the enculturated apes significantly outperformed their standard reared counterparts on the cognitive tasks and this was particularly true for measures of communication. Furthermore, the performance of the enculturated apes was very similar to previously reported data from 2.5-year-old children. We conclude that apes who are reared in a human-like socio-communicatively rich environment develop superior communicative abilities compared to apes reared in standard laboratory settings, which supports some assumptions of the cultural intelligence hypothesis. 2011 Blackwell Publishing Ltd.
Water as consumed and its impact on the consumer--do we understand the variables?
Bates, A J
2000-01-01
Water is the most important natural resource in the world, without it life cannot exist. In 1854 a cholera outbreak in London caused 10, 000 deaths and positively linked enteric disease with bacterial contamination of drinking water by sewage pollution. Since then, adequate water hygiene standards and sewage purification have played the most significant role in disease eradication and public health improvements everywhere. Standards for drinking water have become an extensive range of microbiological and chemical parametric values. Which has not increased consumer, if the media is to be believed. Customers rightly expect that the water they drink is safe and wholesome. Standard setting is perceived as a precise science and meaningful to health. Is this justified and do scientists and regulators who derive and set the standards understand the uncertainties in the system? Water is the universal solvent, therefore it will never be pure; it will contain impurities prior to and after treatment. Knowledge of its potential to become contaminated is necessary to understand the epidemiology associated with waterborne contaminants and their effects. Water use patterns vary considerably and affect assumptions based on toxicology derived from laboratory studies under tightly controlled conditions. Consideration must be given to the model systems used to assess toxicity and translate results from the laboratory to the real world, if sensible scientifically-based water quality standards are to be set and achieved cost effectively.
ERIC Educational Resources Information Center
Oser, Rachel; Fraser, Barry J.
2015-01-01
As society becomes increasingly global and experiential, research suggests that students can benefit from alternative learning environments that extend beyond the classroom. In providing students with laboratory experiences that otherwise would not be possible in high-school settings, virtual laboratories can simulate real laboratories and…
ERIC Educational Resources Information Center
Wheeler, Lindsay B.; Maeng, Jennifer L.; Chiu, Jennie L.; Bell, Randy L.
2017-01-01
This study explores the relationship between teaching assistants (TAs) and student learning in undergraduate science laboratory classes. TAs typically instruct laboratory courses, yet little, if any, research examines professional development (PD) for TAs or relationships between instructors and students in laboratory settings. The use of…
9 CFR 439.53 - Revocation of accreditation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ACCREDITATION OF NON-FEDERAL CHEMISTRY LABORATORIES § 439.53 Revocation of accreditation. The accreditation of a laboratory will be revoked for the following reasons: (a) An accredited laboratory that is accredited to.... If the accredited laboratory fails to meet any of the criteria set forth in §§ 439.20(d) and 439.20(h...
Willmott, Micky; Nicholson, Alexandra; Busse, Heide; MacArthur, Georgina J; Brookes, Sara; Campbell, Rona
2016-01-01
To undertake a systematic review and meta-analysis to establish the effectiveness of handwashing in reducing absence and/or the spread of respiratory tract (RT) and/or gastrointestinal (GI) infection among school-aged children and/or staff in educational settings. Randomised-controlled trials (RCTs). Schools and other settings with a formal educational component in any country. Children aged 3-11 years, and/or staff working with them. Interventions with a hand hygiene component. Incidence of RT or GI infections or symptoms related to such infections; absenteeism; laboratory results of RT and/or GI infections. Eighteen cluster RCTs were identified; 13 school-based, 5 in child day care facilities or preschools. Studies were heterogeneous and had significant quality issues including small numbers of clusters and participants and inadequate randomisation. Individual study results suggest interventions may reduce children's absence, RT infection incidence and symptoms, and laboratory confirmed influenza-like illness. Evidence of impact on GI infection or symptoms was equivocal. Studies are generally not well executed or reported. Despite updating existing systematic reviews and identifying new studies, evidence of the effect of hand hygiene interventions on infection incidence in educational settings is mostly equivocal but they may decrease RT infection among children. These results update and add to knowledge about this crucial public health issue in key settings with a vulnerable population. More robust, well reported cluster RCTs which learn from existing studies, are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Danner, Lukas; Ristic, Renata; Johnson, Trent E; Meiselman, Herbert L; Hoek, Annet C; Jeffery, David W; Bastian, Susan E P
2016-11-01
This study investigated the effect of different contexts on consumers' mood, product-evoked emotions, liking and willingness to pay for wine. Three consumer trials (n=114, 115, and 120) examined 3 different sample sets of 4 Australian commercial Shiraz wines. Each sample set was comprised of a high, medium-high, medium-low and low quality wine as designated by an expert panel. Wine consumers evaluated the same set of wines in the three different contexts, ranging from a highly-controlled laboratory setting to more realistic restaurant and at-home settings. Results showed that high quality wines were liked more and elicited more intense emotions of positive valence compared to wines of lower quality. Context effects were observed on emotions, but not on liking, indicating that although emotions and liking are correlated, the measurement of emotions can deliver additional information over liking. Tasting wine in the restaurant context evoked more intense positive emotions compared to the home and laboratory contexts. Participants' mood before tasting the wines had a strong influence on consecutive product-evoked emotion ratings, but only weak influence on liking ratings. Furthermore, a strong relationship between wine-evoked emotions and willingness to pay was observed, showing that if a wine-evoked more intense emotion of positive valence e.g., contented, enthusiastic, happy, optimistic and passionate participants were willing to pay significantly more for a bottle. Additionally, the absence of negative emotions, even if typically evoked to a very weak extent, is a requirement for an increased willingness to pay. This study indicates it is worthwhile to consider context and emotions in wine testing and marketing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Laboratory errors and patient safety.
Miligy, Dawlat A
2015-01-01
Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that evaluated the encountered laboratory errors and launch the great need for universal standardization and bench marking measures to control the laboratory work.
A dual-loop model of the human controller in single-axis tracking tasks
NASA Technical Reports Server (NTRS)
Hess, R. A.
1977-01-01
A dual loop model of the human controller in single axis compensatory tracking tasks is introduced. This model possesses an inner-loop closure which involves feeding back that portion of the controlled element output rate which is due to control activity. The sensory inputs to the human controller are assumed to be system error and control force. The former is assumed to be sensed via visual, aural, or tactile displays while the latter is assumed to be sensed in kinesthetic fashion. A nonlinear form of the model is briefly discussed. This model is then linearized and parameterized. A set of general adaptive characteristics for the parameterized model is hypothesized. These characteristics describe the manner in which the parameters in the linearized model will vary with such things as display quality. It is demonstrated that the parameterized model can produce controller describing functions which closely approximate those measured in laboratory tracking tasks for a wide variety of controlled elements.
Combined Space and Water Heating: Next Steps to Improved Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Schoenbauer; Bohac, D.; Huelman, P.
2016-07-13
A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%–4.3% (20–40 therms/year) savings for storage andmore » hybrid water heater combi systems operated in moderate-load homes. The full modulation control showed additional savings over set point control (in high-load homes almost doubling the savings: 4%–5% over the no-control case). At the time of installation the reset control can be implemented for $200–$400, which would provide paybacks of 6–25 years for low-load houses and 3–15 years for high-load houses. Full modulation implementation costs would be similar to the outdoor reset and would provide paybacks of 5-½–20 years for low-load houses and 2-½–10 years for high-load houses.« less
Howson, E L A; Armson, B; Lyons, N A; Chepkwony, E; Kasanga, C J; Kandusi, S; Ndusilo, N; Yamazaki, W; Gizaw, D; Cleaveland, S; Lembo, T; Rauh, R; Nelson, W M; Wood, B A; Mioulet, V; King, D P; Fowler, V L
2018-02-01
Effective control and monitoring of foot-and-mouth disease (FMD) relies upon rapid and accurate disease confirmation. Currently, clinical samples are usually tested in reference laboratories using standardized assays recommended by The World Organisation for Animal Health (OIE). However, the requirements for prompt and serotype-specific diagnosis during FMD outbreaks, and the need to establish robust laboratory testing capacity in FMD-endemic countries have motivated the development of simple diagnostic platforms to support local decision-making. Using a portable thermocycler, the T-COR™ 8, this study describes the laboratory and field evaluation of a commercially available, lyophilized pan-serotype-specific real-time RT-PCR (rRT-PCR) assay and a newly available FMD virus (FMDV) typing assay (East Africa-specific for serotypes: O, A, Southern African Territories [SAT] 1 and 2). Analytical sensitivity, diagnostic sensitivity and specificity of the pan-serotype-specific lyophilized assay were comparable to that of an OIE-recommended laboratory-based rRT-PCR (determined using a panel of 57 FMDV-positive samples and six non-FMDV vesicular disease samples for differential diagnosis). The FMDV-typing assay was able to correctly identify the serotype of 33/36 FMDV-positive samples (no cross-reactivity between serotypes was evident). Furthermore, the assays were able to accurately detect and type FMDV RNA in multiple sample types, including epithelial tissue suspensions, serum, oesophageal-pharyngeal (OP) fluid and oral swabs, both with and without the use of nucleic acid extraction. When deployed in laboratory and field settings in Tanzania, Kenya and Ethiopia, both assays reliably detected and serotyped FMDV RNA in samples (n = 144) collected from pre-clinical, clinical and clinically recovered cattle. These data support the use of field-ready rRT-PCR platforms in endemic settings for simple, highly sensitive and rapid detection and/or characterization of FMDV. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
Sediment and erosion control laboratory facility expansion.
DOT National Transportation Integrated Search
2016-08-01
The Sediment and Erosion Control Laboratory (SEC Lab), formerly the Hydraulics, Sedimentation, and : Erosion Control Laboratory, is operated by the Texas A&M Transportation Institutes Environment and : Planning Program. Performance evaluation prog...
Lee, J.Y.; Santamarina, J.C.; Ruppel, C.
2010-01-01
The marked decrease in bulk electrical conductivity of sediments in the presence of gas hydrates has been used to interpret borehole electrical resistivity logs and, to a lesser extent, the results of controlled source electromagnetic surveys to constrain the spatial distribution and predicted concentration of gas hydrate in natural settings. Until now, an exhaustive laboratory data set that could be used to assess the impact of gas hydrate on the electromagnetic properties of different soils (sand, silt, and clay) at different effective stress and with different saturations of hydrate has been lacking. The laboratory results reported here are obtained using a standard geotechnical cell and the hydrate-formed tetrahydrofuran (THF), a liquid that is fully miscible in water and able to produce closely controlled saturations of hydrate from dissolved phase. Both permittivity and electrical conductivity are good indicators of the volume fraction of free water in the sediment, which is in turn dependent on hydrate saturation. Permittivity in the microwave frequency range is particularly predictive of free water content since it is barely affected by ionic concentration, pore structure, and surface conduction. Electrical conductivity (or resistivity) is less reliable for constraining water content or hydrate saturation: In addition to fluid-filled porosity, other factors, such as the ionic concentration of the pore fluid and possibly other conduction effects (e.g., surface conduction in high specific surface soils having low conductivity pore fluid), also influence electrical conductivity.
Contributions of CCLM to advances in quality control.
Kazmierczak, Steven C
2013-01-01
Abstract The discipline of laboratory medicine is relatively young when considered in the context of the history of medicine itself. The history of quality control, within the context of laboratory medicine, also enjoys a relatively brief, but rich history. Laboratory quality control continues to evolve along with advances in automation, measurement techniques and information technology. Clinical Chemistry and Laboratory Medicine (CCLM) has played a key role in helping disseminate information about the proper use and utility of quality control. Publication of important advances in quality control techniques and dissemination of guidelines concerned with laboratory quality control has undoubtedly helped readers of this journal keep up to date on the most recent developments in this field.
Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti
2014-09-01
To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.
Teaching Engineering Design in a Laboratory Setting
ERIC Educational Resources Information Center
Hummon, Norman P.; Bullen, A. G. R.
1974-01-01
Discusses the establishment of an environmental systems laboratory at the University of Pittsburgh with the support of the Sloan Foundation. Indicates that the "real world" can be brought into the laboratory by simulating on computers, software systems, and data bases. (CC)
As a founding member organization of ATOM, the Frederick National Laboratory will contribute scientific expertise in precision oncology, computational chemistry and cancer biology, as well as support for open sharing of data sets and predictive model
Validity and Reliability of Devices That Assess Body Temperature During Indoor Exercise in the Heat
Ganio, Matthew S; Brown, Christopher M; Casa, Douglas J; Becker, Shannon M; Yeargin, Susan W; McDermott, Brendon P; Boots, Lindsay M; Boyd, Paul W; Armstrong, Lawrence E; Maresh, Carl M
2009-01-01
Context: When assessing exercise hyperthermia outdoors, the validity of certain commonly used body temperature measuring devices has been questioned. A controlled laboratory environment is generally less influenced by environmental factors (eg, ambient temperature, solar radiation, wind) than an outdoor setting. The validity of these temperature measuring devices in a controlled environment may be more acceptable. Objective: To assess the validity and reliability of commonly used temperature devices compared with rectal temperature in individuals exercising in a controlled, high environmental temperature indoor setting and then resting in a cool environment. Design: Time series study. Setting: Laboratory environmental chamber (temperature = 36.4 ± 1.2°C [97.5 ± 2.16°F], relative humidity = 52%) and cool laboratory (temperature = approximately 23.3°C [74.0°F], relative humidity = 40%). Patients or Other Participants: Fifteen males and 10 females. Intervention(s): Rectal, gastrointestinal, forehead, oral, aural, temporal, and axillary temperatures were measured with commonly used temperature devices. Temperature was measured before and 20 minutes after entering the environmental chamber, every 30 minutes during a 90-minute treadmill walk in the heat, and every 20 minutes during a 60-minute rest in mild conditions. Device validity and reliability were assessed with various statistical measures to compare the measurements using each device with rectal temperature. A device was considered invalid if the mean bias (average difference between rectal and device temperatures) was more than ±0.27°C (±0.50°F). Main Outcome Measure(s): Measured temperature from each device (mean and across time). Results: The following devices provided invalid estimates of rectal temperature: forehead sticker (0.29°C [0.52°F]), oral temperature using an inexpensive device (−1.13°C [−2.03°F]), temporal temperature measured according to the instruction manual (−0.87°C [−1.56°F]), temporal temperature using a modified technique (−0.63°C [−1.13°F]), oral temperature using an expensive device (−0.86°C, [−1.55°F]), aural temperature (−0.67°C, [−1.20°F]), axillary temperature using an inexpensive device (−1.25°C, [−2.24°F]), and axillary temperature using an expensive device (−0.94°F [−1.70°F]). Measurement of intestinal temperature (mean bias of −0.02°C [−0.03°F]) was the only device considered valid. Devices measured in succession (intestinal, forehead, temporal, and aural) showed acceptable reliability (all had a mean bias = 0.09°C [0.16°F] and r ≥ 0.94]). Conclusions: Even during laboratory exercise in a controlled environment, devices used to measure forehead, temporal, oral, aural, and axillary body sites did not provide valid estimates of rectal temperature. Only intestinal temperature measurement met the criterion. Therefore, we recommend that rectal or intestinal temperature be used to assess hyperthermia in individuals exercising indoors in the heat. PMID:19295956
Setting the agenda: a new model for collaborative tuberculosis epidemiologic research.
Katz, Dolly; Albalak, Rachel; Wing, J S; Combs, V
2007-01-01
Success in reducing tuberculosis (TB) incidence in developed nations has created a paradoxical problem for researchers. In many countries, there are too few cases to support the research necessary to maintain and accelerate the decline. We describe an approach to applied TB research that supports and focuses efforts of researchers at 21 academic, clinical, and governmental sites in two countries. The Tuberculosis Epidemiologic Studies Consortium (TBESC), funded by the Centers for Disease Control and Prevention (CDC) and by outside sources, conducts programmatically relevant epidemiologic, behavioral, economic, laboratory, and operational research for TB prevention and control. Our experience may serve as a model for other types of applied health care research.
Optimization of 15 parameters influencing the long-term survival of bacteria in aquatic systems
NASA Technical Reports Server (NTRS)
Obenhuber, D. C.
1993-01-01
NASA is presently engaged in the design and development of a water reclamation system for the future space station. A major concern in processing water is the control of microbial contamination. As a means of developing an optimal microbial control strategy, studies were undertaken to determine the type and amount of contamination which could be expected in these systems under a variety of changing environmental conditions. A laboratory-based Taguchi optimization experiment was conducted to determine the ideal settings for 15 parameters which influence the survival of six bacterial species in aquatic systems. The experiment demonstrated that the bacterial survival period could be decreased significantly by optimizing environmental conditions.
A Web-Based Remote Access Laboratory Using SCADA
ERIC Educational Resources Information Center
Aydogmus, Z.; Aydogmus, O.
2009-01-01
The Internet provides an opportunity for students to access laboratories from outside the campus. This paper presents a Web-based remote access real-time laboratory using SCADA (supervisory control and data acquisition) control. The control of an induction motor is used as an example to demonstrate the effectiveness of this remote laboratory,…
Ondoa, Pascale; Datema, Tjeerd; Keita-Sow, Mah-Sere; Ndihokubwayo, Jean-Bosco; Isadore, Jocelyn; Oskam, Linda; Nkengasong, John; Lewis, Kim
2016-01-01
Functional national laboratory networks and systems are indispensable to the achievement of global health security targets according to the International Health Regulations. The lack of indicators to measure the functionality of national laboratory network has limited the efficiency of past and current interventions to enhance laboratory capacity in resource-limited-settings. We have developed a matrix for the assessment of national laboratory network functionality and progress thereof, with support from the African Society of Laboratory Medicine and the Association of Public Health Laboratories. The laboratory network (LABNET) scorecard was designed to: (1) Measure the status of nine overarching core capabilities of laboratory network required to achieve global health security targets, as recommended by the main normative standards; (2) Complement the World Health Organization joint external evaluation tool for the assessment of health system preparedness to International Health Regulations (2005) by providing detailed information on laboratory systems; and (3) Serve as a clear roadmap to guide the stepwise implementation of laboratory capability to prevent, detect and act upon infectious threats. The application of the LABNET scorecard under the coordination of the African Society of Laboratory Medicine and the Association of Public Health Laboratories could contribute to the design, monitoring and evaluation of upcoming Global Health Security Agenda-supported laboratory capacity building programmes in sub Saharan-Africa and other resource-limited settings, and inform the development of national laboratory policies and strategic plans. Endorsement by the World Health Organization Regional Office for Africa is foreseen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cada, G.F.; Solomon, J.A.; Loar, J.M.
This report provides a review of literature concerning the effects of sublethal stresses on predator-prey interactions in aquatic systems. In addition, the results of a preliminary laboratory study of the susceptibility of entrainment-stressed juvenile bluegill to striped bass predation are presented. Juvenile bluegill were exposed to thermal and physical entrainment stresses in the ORNL Power Plant Simulator and subsequently to predation by juvenile striped bass in a susceptibility to predation experimental design. None of the entrainment stresses tested (thermal shock, physical effects of pump and condenser passage, and combination of thermal and physical shock) was found to significantly increase predationmore » rates as compared to controls, and no significant interactions between thermal and physical stresses were detected. The validity of laboratory predator-prey studies and the application of indirect mortality information for setting protective standards and predicting environmental impacts are discussed.« less
ETHOWATCHER: validation of a tool for behavioral and video-tracking analysis in laboratory animals.
Crispim Junior, Carlos Fernando; Pederiva, Cesar Nonato; Bose, Ricardo Chessini; Garcia, Vitor Augusto; Lino-de-Oliveira, Cilene; Marino-Neto, José
2012-02-01
We present a software (ETHOWATCHER(®)) developed to support ethography, object tracking and extraction of kinematic variables from digital video files of laboratory animals. The tracking module allows controlled segmentation of the target from the background, extracting image attributes used to calculate the distance traveled, orientation, length, area and a path graph of the experimental animal. The ethography module allows recording of catalog-based behaviors from environment or from video files continuously or frame-by-frame. The output reports duration, frequency and latency of each behavior and the sequence of events in a time-segmented format, set by the user. Validation tests were conducted on kinematic measurements and on the detection of known behavioral effects of drugs. This software is freely available at www.ethowatcher.ufsc.br. Copyright © 2011 Elsevier Ltd. All rights reserved.
Quality control for federal clean water act and safe drinking water act regulatory compliance.
Askew, Ed
2013-01-01
QC sample results are required in order to have confidence in the results from analytical tests. Some of the AOAC water methods include specific QC procedures, frequencies, and acceptance criteria. These are considered to be the minimum controls needed to perform the method successfully. Some regulatory programs, such as those in 40 CFR Part 136.7, require additional QC or have alternative acceptance limits. Essential QC measures include method calibration, reagent standardization, assessment of each analyst's capabilities, analysis of blind check samples, determination of the method's sensitivity (method detection level or quantification limit), and daily evaluation of bias, precision, and the presence of laboratory contamination or other analytical interference. The details of these procedures, their performance frequency, and expected ranges of results are set out in this manuscript. The specific regulatory requirements of 40 CFR Part 136.7 for the Clean Water Act, the laboratory certification requirements of 40 CFR Part 141 for the Safe Drinking Water Act, and the ISO 17025 accreditation requirements under The NELAC Institute are listed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gressel, M.G.
1990-12-01
The goal of the study was to develop and evaluate local exhaust ventilation controls which will reduce the embalmer's exposure to formaldehyde (50000). The Cincinnati College of Mortuary Science had three tables set up for conducting embalmings. Two of the tables were in a large room which serves as a laboratory for the students. The third was located in an isolation room and was used primarily for suspected infectious cases. All the embalmings conducted for the study were conducted in the isolation room and all involved noninfectious bodies. The local exhaust ventilation system developed for the mortuary consisted of 6more » foot slot hoods on either side of the embalming table. Of the 32 personal samples taken, the formaldehyde concentration of five samples showed a concentration of 1 part per million. The author recommends that a local exhaust ventilation system similar to the design tested here be installed permanently in the isolation room and on the other tables in the main embalming laboratory.« less
Martian Cryogenic Carbonate Formation: Stable Isotope Variations Observed in Laboratory Studies
NASA Technical Reports Server (NTRS)
Socki, Richard A.; Niles, Paul B.; Sun, Tao; Fu, Qi; Romanek, Christopher S.; Gibson, Everett K. Jr.
2014-01-01
The history of water on Mars is tied to the formation of carbonates through atmospheric CO2 and its control of the climate history of the planet. Carbonate mineral formation under modern martian atmospheric conditions could be a critical factor in controlling the martian climate in a means similar to the rock weathering cycle on Earth. The combination of evidence for liquid water on the martian surface and cold surface conditions suggest fluid freezing could be very common on the surface of Mars. Cryogenic calcite forms easily from freezing solutions when carbon dioxide degasses quickly from Ca-bicarbonate-rich water, a process that has been observed in some terrestrial settings such as arctic permafrost cave deposits, lake beds of the Dry Valleys of Antarctica, and in aufeis (river icings) from rivers of N.E. Alaska. A series of laboratory experiments were conducted that simulated cryogenic carbonate formation on Mars in order to understand their isotopic systematics. The results indicate that carbonates grown under martian conditions show variable enrichments from starting bicarbonate fluids in both carbon and oxygen isotopes beyond equilibrium values.
Kiani, Roozbeh; Hanks, Timothy D; Shadlen, Michael N
2008-03-19
Decisions about sensory stimuli are often based on an accumulation of evidence in time. When subjects control stimulus duration, the decision terminates when the accumulated evidence reaches a criterion level. Under many natural circumstances and in many laboratory settings, the environment, rather than the subject, controls the stimulus duration. In these settings, it is generally assumed that subjects commit to a choice at the end of the stimulus stream. Indeed, failure to benefit from the full stream of information is interpreted as a sign of imperfect accumulation or memory leak. Contrary to these assumptions, we show that monkeys performing a direction discrimination task commit to a choice when the accumulated evidence reaches a threshold level (or bound), sometimes long before the end of stimulus. This bounded accumulation of evidence is reflected in the activity of neurons in the lateral intraparietal cortex. Thus, the readout of visual cortex embraces a termination rule to limit processing even when potentially useful information is available.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Clinical Laboratory Improvement Advisory Committee, Centers for Disease Control and Prevention: Notice of Charter..., that the Clinical Laboratory Improvement Advisory Committee, Centers for Disease Control and Prevention...
Description of the Spacecraft Control Laboratory Experiment (SCOLE) facility
NASA Technical Reports Server (NTRS)
Williams, Jeffrey P.; Rallo, Rosemary A.
1987-01-01
A laboratory facility for the study of control laws for large flexible spacecraft is described. The facility fulfills the requirements of the Spacecraft Control Laboratory Experiment (SCOLE) design challenge for a laboratory experiment, which will allow slew maneuvers and pointing operations. The structural apparatus is described in detail sufficient for modelling purposes. The sensor and actuator types and characteristics are described so that identification and control algorithms may be designed. The control implementation computer and real-time subroutines are also described.
Description of the Spacecraft Control Laboratory Experiment (SCOLE) facility
NASA Technical Reports Server (NTRS)
Williams, Jeffrey P.; Rallo, Rosemary A.
1987-01-01
A laboratory facility for the study of control laws for large flexible spacecraft is described. The facility fulfills the requirements of the Spacecraft Control Laboratory Experiment (SCOLE) design challenge for laboratory experiments, which will allow slew maneuvers and pointing operations. The structural apparatus is described in detail sufficient for modelling purposes. The sensor and actuator types and characteristics are described so that identification and control algorithms may be designed. The control implementation computer and real-time subroutines are also described.
ERIC Educational Resources Information Center
Mok, Heng Ngee; Lee, Yeow Leong; Tan, Wee Kiat
2012-01-01
This paper describes how a generic computer laboratory equipped with 52 workstations is set up for teaching IT-related courses and other general purpose usage. The authors have successfully constructed a lab management system based on decentralised, client-side software virtualisation technology using Linux and free software tools from VMware that…
Controlling the emission profile of an H2 discharge lamp to simulate interstellar radiation fields
NASA Astrophysics Data System (ADS)
Ligterink, N. F. W.; Paardekooper, D. M.; Chuang, K.-J.; Both, M. L.; Cruz-Diaz, G. A.; van Helden, J. H.; Linnartz, H.
2015-12-01
Context. Microwave discharge hydrogen-flow lamps have been used for more than half a century to simulate interstellar ultraviolet radiation fields in the laboratory. Recent discrepancies between identical measurements in different laboratories, as well as clear wavelength dependent results obtained in monochromatic (synchrotron) experiments, hint at a more elaborate dependence on the exact discharge settings than assumed so far. Aims: We have investigated systematically two lamp geometries in full dependence of a large number of different running conditions and the spectral emission patterns are characterized for the first time with fully calibrated absolute flux numbers. Methods: A sophisticated plasma lamp calibration set-up has been used to record the vacuum-ultraviolet emission spectra with a spectral resolution of 0.5 nm and bandwidth of 1.6 nm in the 116-220 nm region. Spectra are compared with the output of a calibrated D2-lamp which allows a derivation of absolute radiance values. Results: The general findings of over 200 individual measurements are presented, illustrating how the lamp emission pattern depends on i) microwave power; ii) gas and gas mixing ratios; iii) discharge lamp geometry; iv) cavity positioning; and v) gas pressure.
Studying marine stratus with large eddy simulation
NASA Technical Reports Server (NTRS)
Moeng, Chin-Hoh
1990-01-01
Data sets from field experiments over the stratocumulus regime may include complications from larger scale variations, decoupled cloud layers, diurnal cycle, or entrainment instability, etc. On top of the already complicated turbulence-radiation-condensation processes within the cloud-topped boundary layer (CTBL), these complexities may sometimes make interpretation of the data sets difficult. To study these processes, a better understanding is needed of the basic processes involved in the prototype CTBL. For example, is cloud top radiative cooling the primary source of the turbulent kinetic energy (TKE) within the CTBL. Historically, laboratory measurements have played an important role in addressing the turbulence problems. The CTBL is a turbulent field which is probably impossible to generate in laboratories. Large eddy simulation (LES) is an alternative way of 'measuring' the turbulent structure under controlled environments, which allows the systematic examination of the basic physical processes involved. However, there are problems with the LES approach for the CTBL. The LES data need to be consistent with the observed data. The LES approach is discussed, and results are given which provide some insights into the simulated turbulent flow field. Problems with this approach for the CTBL and information from the FIRE experiment needed to justify the LES results are discussed.
Artificial Optical Radiation photobiological hazards in arc welding.
Gourzoulidis, G A; Achtipis, A; Topalis, F V; Kazasidis, M E; Pantelis, D; Markoulis, A; Kappas, C; Bourousis, C A
2016-08-01
Occupational Health and Safety (OHS) is associated with crucial social, economic, cultural and technical issues. A highly specialized OHS sector deals with the photobiological hazards from artificial optical radiation (AOR), which is divided into visible light, UV and IR emitted during various activities and which is legally covered by European Directive 2006/25/EC. Among the enormous amount of sources emitting AOR, the most important non-coherent ones to consider for health effects to the whole optical range, are arcs created during metal welding. This survey presents the effort to assess the complicated exposure limits of the Directive in the controlled environment of a welding laboratory. Sensors covering the UV and blue light range were set to measure typical welding procedures reproduced in the laboratory. Initial results, apart from apparently justifying the use of Personal Protective Equipment (PPE) due to even subsecond overexposures measured, also set the basis to evaluate PPE's properties and support an integrated risk assessment of the complex welding environment. These results can also improve workers' and employer's information and training about radiation hazards, which is a crucial OHS demand. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Kim, Won S.; Bejczy, Antal K.
1993-01-01
A highly effective predictive/preview display technique for telerobotic servicing in space under several seconds communication time delay has been demonstrated on a large laboratory scale in May 1993, involving the Jet Propulsion Laboratory as the simulated ground control station and, 2500 miles away, the Goddard Space Flight Center as the simulated satellite servicing set-up. The technique is based on a high-fidelity calibration procedure that enables a high-fidelity overlay of 3-D graphics robot arm and object models over given 2-D TV camera images of robot arm and objects. To generate robot arm motions, the operator can confidently interact in real time with the graphics models of the robot arm and objects overlaid on an actual camera view of the remote work site. The technique also enables the operator to generate high-fidelity synthetic TV camera views showing motion events that are hidden in a given TV camera view or for which no TV camera views are available. The positioning accuracy achieved by this technique for a zoomed-in camera setting was about +/-5 mm, well within the allowable +/-12 mm error margin at the insertion of a 45 cm long tool in the servicing task.
Coseismic landslides reveal near-surface rock strength in a high-relief tectonically active setting
Gallen, Sean F.; Clark, Marin K.; Godt, Jonathan W.
2014-01-01
We present quantitative estimates of near-surface rock strength relevant to landscape evolution and landslide hazard assessment for 15 geologic map units of the Longmen Shan, China. Strength estimates are derived from a novel method that inverts earthquake peak ground acceleration models and coseismic landslide inventories to obtain material proper- ties and landslide thickness. Aggregate rock strength is determined by prescribing a friction angle of 30° and solving for effective cohesion. Effective cohesion ranges are from 70 kPa to 107 kPa for 15 geologic map units, and are approximately an order of magnitude less than typical laboratory measurements, probably because laboratory tests on hand-sized specimens do not incorporate the effects of heterogeneity and fracturing that likely control near-surface strength at the hillslope scale. We find that strength among the geologic map units studied varies by less than a factor of two. However, increased weakening of units with proximity to the range front, where precipitation and active fault density are the greatest, suggests that cli- matic and tectonic factors overwhelm lithologic differences in rock strength in this high-relief tectonically active setting.
Stolzenburg, Jens-Uwe; Kallidonis, Panagiotis; Oh, Min-A; Ghulam, Nabi; Do, Minh; Haefner, Tim; Dietel, Anja; Till, Holger; Sakellaropoulos, George; Liatsikos, Evangelos N
2010-02-01
Laparoendoscopic single-site surgery (LESS) represents the latest innovation in laparoscopic surgery. We compare in dry and animal laboratory the efficacy of recently introduced pre-bent instruments with conventional laparoscopic and flexible instruments in terms of time requirement, maneuverability, and ease of handling. Participants of varying laparoscopic experience were included in the study and divided in groups according to their experience. The participants performed predetermined tasks in dry laboratory using all sets of instruments. An experienced laparoscopic surgeon performed 24 nephrectomies in 12 pigs using all sets of instruments. Single port was used for all instrument sets except for the conventional instruments, which were inserted through three ports. The time required for the performance of dry laboratory tasks and the porcine nephrectomies was recorded. Errors in the performance of dry laboratory tasks of each instrument type were also recorded. Pre-bent instruments had a significant advantage over flexible instruments in terms of time requirement to accomplish tasks and procedures as well as maneuverability. Flexible instruments were more time consuming in comparison to the conventional laparoscopic instruments during the performance of the tasks. There were no significant differences in the time required for the accomplishment of dry laboratory tasks or steps of nephrectomy using conventional instruments through appropriate number of ports in comparison to pre-bent instruments through single port. Pre-bent instruments were less time consuming and with better maneuverability in comparison to flexible instruments in experimental single-port access surgery. Further clinical investigations would elucidate the efficacy of pre-bent instruments.
Ajayi, Nnennaya A; Nwigwe, Chinedu G; Azuogu, Ben N; Onyire, Benson N; Nwonwu, Elizabeth U; Ogbonnaya, Lawrence U; Onwe, Francis I; Ekaete, Tobin; Günther, Stephan; Ukwaja, Kingsley N
2013-11-01
Despite the epidemic nature of Lassa fever (LF), details of outbreaks and response strategies have not been well documented in resource-poor settings. We describe the course of a LF outbreak in Ebonyi State, Nigeria, during January to March 2012. We analyzed clinical, epidemiological, and laboratory data from surveillance records and hospital statistics during the outbreak. Fisher's exact tests were used to compare proportions and t-tests to compare differences in means. The outbreak response consisted of effective coordination, laboratory testing, active surveillance, community mobilization, contact and suspected case evaluation, and case management. Twenty LF cases (10 confirmed and 10 suspected) were recorded during the outbreak. Nosocomial transmission to six health workers occurred through the index case. Only 1/110 contacts had an asymptomatic infection. Overall, there was high case fatality rate among all cases (6/20; 30%). Patients who received ribavirin were less likely to die than those who did not (p=0.003). The mean delay to presentation for patients who died was 11 ± 3.5 days, while for those who survived was 6 ± 2.6 days (p<0.001). The response strategies contained the epidemic. Challenges to control efforts included poor local laboratory capacity, inadequate/poor quality of protective materials, fear among health workers, and inadequate emergency preparedness. Copyright © 2013 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Managing laboratory test ordering through test frequency filtering.
Janssens, Pim M W; Wasser, Gerd
2013-06-01
Modern computer systems allow limits to be set on the periods allowed for repetitive testing. We investigated a computerised system for managing potentially overtly frequent laboratory testing, calculating the financial savings obtained. In consultation with hospital physicians, tests were selected for which 'spare periods' (periods during which tests are barred) might be set to control repetitive testing. The tests were selected and spare periods determined based on known analyte variations in health and disease, variety of tissues or cells giving rise to analytes, clinical conditions and rate of change determining analyte levels, frequency with which doctors need information about the analytes and the logistical needs of the clinic. The operation and acceptance of the system was explored with 23 analytes. Frequency filtering was subsequently introduced for 44 tests, each with their own spare periods. The proportion of tests barred was 0.56%, the most frequent of these being for total cholesterol, uric acid and HDL-cholesterol. The financial savings were 0.33% of the costs of all testing, with HbA1c, HDL-cholesterol and vitamin B12 yielding the largest savings. Following the introduction of the system the number of barred tests ultimately decreased, suggesting accommodation by the test requestors. Managing laboratory testing through computerised limits to prevent overtly frequent testing is feasible. The savings were relatively low, but sustaining the system takes little effort, giving little reason not to apply it. The findings will serve as a basis for improving the system and may guide others in introducing similar systems.
Light field and water clarity simulation of natural environments in laboratory conditions
NASA Astrophysics Data System (ADS)
Pe'eri, Shachak; Shwaery, Glenn
2012-06-01
Simulation of natural oceanic conditions in a laboratory setting is a challenging task, especially when that environment can be miles away. We present an attempt to replicate the solar radiation expected at different latitudes with varying water clarity conditions up to 30 m in depth using a 2.5 m deep engineering tank at the University of New Hampshire. The goals of the study were: 1) to configure an underwater light source that produced an irradiance spectrum similar to natural daylight with the sun at zenith and at 60° under clear atmospheric conditions, and 2) to monitor water clarity as a function of depth. Irradiance was measured using a spectra-radiometer with a cosine receiver to analyze the output spectrum of submersed lamps as a function of distance. In addition, an underwater reflection method was developed to measure the diffuse attenuation coefficient in real time. Two water clarity types were characterized, clear waters representing deep, open-ocean conditions, and murky waters representing littoral environments. Results showed good correlation between the irradiance measured at 400 nm to 600 nm and the natural daylight spectrum at 3 m from the light source. This can be considered the water surface conditions reference. Using these methodologies in a controlled laboratory setting, we are able to replicate illumination and water conditions to study the physical, chemical and biological processes on natural and man-made objects and/or systems in simulated, varied geographic locations and environments.
Zhao-Hui, Zheng; Jun, Qin; Li, Chen; Hong, Zhu; Li, Tang; Zu-Wu, Tu; Ming-Xing, Zeng; Qian, Sun; Shun-Xiang, Cai
2016-10-09
To analyze the construction and operation status of management system of laboratories of schistosomiasis control institutions in Hubei Province, so as to provide the reference for the standardized detection and management of schistosomiasis laboratories. According to the laboratory standard of schistosomiasis at provincial, municipal and county levels, the management system construction and operation status of 60 schistosomiasis control institutions was assessed by the acceptance examination method from 2013 to 2015. The management system was already occupied over all the laboratories of schistosomiasis control institutions and was officially running. There were 588 non-conformities and the inconsistency rate was 19.60%. The non-conformity rate of the management system of laboratory quality control was 38.10% (224 cases) and the non-conformity rate of requirements of instrument and equipment was 23.81% (140 cases). The management system has played an important role in the standardized management of schistosomiasis laboratories.
Blanckenhorn, Wolf U; Puniamoorthy, Nalini; Schäfer, Martin A; Scheffczyk, Adam; Römbke, Jörg
2013-03-01
Veterinary pharmaceuticals excreted in the dung of treated livestock can have strong non-target effects on the dung organism community. We report results of ecotoxicological tests with ivermectin for 21 species of temperate (Europe, North America) and tropical (Asia, Central America) black scavenger flies (Diptera: Sepsidae), using standardized methods developed previously for the yellow dung fly and the face fly. Our study documents great variation in ivermectin sensitivity of more than two orders of magnitude among species and even populations within species: estimated lethal effect concentrations LC(50) (at which 50% of the flies died) ranged from 0.05 to 18.55 μg/kg dung fresh weight (equivalent to 0.33-132.22 μg/kg dung dry weight). We also show that controlled laboratory tests can--within reasonable limits-be extended to the field or to laboratory settings without climate control, as obtained LC(50) were roughly similar. In addition to lethal effects, our study revealed relevant sub-lethal effects at lower ivermectin concentrations in terms of prolonged development, smaller body size and reduced juvenile growth rate. Finally, oviposition choice experiments showed that females generally do not discriminate against dung containing ivermectin residues. We conclude that sepsid flies are well suited test organisms for pharmaceutical residues in the dung of livestock due to their ease and speed of rearing and handling, particularly in the tropics, where high-tech laboratory equipment is often not available. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Feldman, J.; Dewers, T. A.; Heath, J. E.; Cather, M.; Mozley, P.
2016-12-01
Multiphase flow in clay-bearing sandstones of the Morrow Sandstone governs the efficiency of CO2 storage and enhanced oil recovery at the Farnsworth Unit, Texas. This formation is the target for enhanced oil recovery and injection of one million metric ton of anthropogenically-sourced CO2. The sandstone hosts eight major flow units that exhibit distinct microstructural characteristics due to diagenesis, including: "clean" macro-porosity; quartz overgrowths constricting some pores; ghost grains; intergranular porosity filled by microporous authigenic clay; and feldspar dissolution. We examine the microstructural controls on macroscale (core scale) relative permeability and capillary pressure behavior through: X-ray computed tomography, Robomet.3d, and focused ion beam-scanning electron microscopy imaging of the pore structure of the major flow units of the Morrow Sandstone; relative permeability and capillary pressure in the laboratory using CO2, brine, and oil at reservoir pressure and effective stress conditions. The combined data sets inform links between patterns of diagenesis and multiphase flow. These data support multiphase reservoir simulation and performance assessment by the Southwest Regional Partnership on Carbon Sequestration (SWP). Funding for this project is provided by the U.S. Department of Energy's National Energy Technology Laboratory through the SWP under Award No. DE-FC26-05NT42591. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
NASA Astrophysics Data System (ADS)
Johnston, Marty; Jalkio, Jeffrey
2013-04-01
By the time students have reached the intermediate level physics courses they have been exposed to a broad set of analytical, experimental, and computational skills. However, their ability to independently integrate these skills into the study of a physical system is often weak. To address this weakness and assess their understanding of the underlying physical concepts we have introduced laboratory homework into lecture based, junior level theoretical mechanics and electromagnetics courses. A laboratory homework set replaces a traditional one and emphasizes the analysis of a single system. In an exercise, students use analytical and computational tools to predict the behavior of a system and design a simple measurement to test their model. The laboratory portion of the exercises is straight forward and the emphasis is on concept integration and application. The short student reports we collect have revealed misconceptions that were not apparent in reviewing the traditional homework and test problems. Work continues on refining the current problems and expanding the problem sets.
A Soft, Wearable Microfluidic Device for the Capture, Storage, and Colorimetric Sensing of Sweat
Koh, Ahyeon; Kang, Daeshik; Xue, Yeguang; Lee, Seungmin; Pielak, Rafal M.; Kim, Jeonghyun; Hwang, Taehwan; Min, Seunghwan; Banks, Anthony; Bastien, Philippe; Manco, Megan C.; Wang, Liang; Ammann, Kaitlyn R.; Jang, Kyung-In; Won, Phillip; Han, Seungyong; Ghaffari, Roozbeh; Paik, Ungyu; Slepian, Marvin J.; Balooch, Guive; Huang, Yonggang; Rogers, John A.
2017-01-01
Capabilities in health monitoring via capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH and concentration of both chloride and lactate. PMID:27881826
... Clinical Overview Diagnosis & Testing Prevention in Health Care Settings Laboratory Testing Collecting VZV Specimens CDC National VZV Laboratory Surveillance Resources & References Multimedia Related Links Medline Plus NIH SeniorHealth ...
Culturing and Using Protozoans in the Laboratory.
ERIC Educational Resources Information Center
Hummer, Paul J., Jr.
1993-01-01
Provides instructions for teachers and students to culture protozoans for use in science laboratories. Sections include setting up a culture area, basic culture media, amoeba culture technique, powdered milk-wheat-rice medium, alfalfa medium, and uses of the protozoa in the laboratory. (PR)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
... in physics, chemistry, mathematics, computer science, or engineering. Institutions should have a 4..., mathematics, computer science, or engineering with work experiences in laboratories or other settings...-0141-01] Professional Research Experience Program in Chemical Science and Technology Laboratory...
ERIC Educational Resources Information Center
Hutt, Johnathon T.; Aron, Zachary D.
2014-01-01
An upper-division organic chemistry laboratory experiment exploring fluorescent sensing over two laboratory periods and part of a third is described. Two functionally distinct pH-responsive sensors are prepared through a dehydrative three-component coupling reaction. During the abbreviated (<1 h) first laboratory period, students set up…
ERIC Educational Resources Information Center
FIEL, NICHOLAS J.; JOHNSTON, RAYMOND F.
A PREPARATION LABORATORY WAS DESIGNED TO FAMILIARIZE STUDENTS IN ADVANCED MAMMALIAN PHYSIOLOGY WITH LABORATORY SKILLS AND TECHNIQUES AND THUS SHORTEN THE TIME THEY SPEND IN SETTING UP ACTUAL EXPERIMENTS. THE LABORATORY LASTS 30 MINUTES, IS FLEXIBLE AND SIMPLE OF OPERATION, AND DOES NOT REQUIRE A PROFESSOR'S PRESENCE. THE BASIC TRAINING UNIT IS THE…
ERIC Educational Resources Information Center
Thoron, Andrew C.; Rubenstein, Eric D.
2013-01-01
Instruction in the laboratory is essential to the success of a total agricultural education program. The development of students' critical thinking, argumentation skills, technical skills, reasoning ability, and engagement are all found within the agriscience laboratory. Yet, utilizing the laboratory setting to its maximum potential is challenging…
Maokola, W; Willey, B A; Shirima, K; Chemba, M; Armstrong Schellenberg, J R M; Mshinda, H; Alonso, P; Tanner, M; Schellenberg, D
2011-06-01
To describe and evaluate the use of handheld computers for the management of Health Management Information System data. Electronic data capture took place in 11 sentinel health centres in rural southern Tanzania. Information from children attending the outpatient department (OPD) and the Expanded Program on Immunization vaccination clinic was captured by trained local school-leavers, supported by monthly supervision visits. Clinical data included malaria blood slides and haemoglobin colour scale results. Quality of captured data was assessed using double data entry. Malaria blood slide results from health centre laboratories were compared to those from the study's quality control laboratory. The system took 5 months to implement, and few staffings or logistical problems were encountered. Over the following 12 months (April 2006-March 2007), 7056 attendances were recorded in 9880 infants aged 2-11 months, 50% with clinical malaria. Monthly supervision visits highlighted incomplete recording of information between OPD and laboratory records, where on average 40% of laboratory visits were missing the record of their corresponding OPD visit. Quality of microscopy from health facility laboratories was lower overall than that from the quality assurance laboratory. Electronic capture of HMIS data was rapidly and successfully implemented in this resource-poor setting. Electronic capture alone did not resolve issues of data completeness, accuracy and reliability, which are essential for management, monitoring and evaluation; suggestions to monitor and improve data quality are made. © 2011 Blackwell Publishing Ltd.
Nano-G research laboratory for a spacecraft
NASA Technical Reports Server (NTRS)
Vonbun, Friedrich O. (Inventor); Garriott, Owen K. (Inventor)
1991-01-01
An acceleration free research laboratory is provided that is confined within a satellite but free of any physical engagement with the walls of the satellite, wherein the laboratory has adequate power, heating, cooling, and communications services to conduct basic research and development. An inner part containing the laboratory is positioned at the center-of-mass of a satellite within the satellite's outer shell. The satellite is then positioned such that its main axes are in a position parallel to its flight velocity vector or in the direction of the residual acceleration vector. When the satellite is in its desired orbit, the inner part is set free so as to follow that orbit without contacting the inside walls of the outer shell. Sensing means detect the position of the inner part with respect to the outer shell, and activate control rockets to move the outer shell; thereby, the inner part is repositioned such that it is correctly positioned at the center-of-mass of the satellite. As a consequence, all disturbing forces, such as drag forces, act on the outer shell, and the inner part containing the laboratory is shielded and is affected only by gravitational forces. Power is supplied to the inner part and to the laboratory by a balanced microwave/laser link which creates the kind of environment necessary for basic research to study critical phenomena such as the Lambda transition in helium and crystal growth, and to perform special metals and alloys research, etc.
Purkis, Stephen W; Drake, Linda; Meger, Michael; Mariner, Derek C
2010-04-01
The European Union (EU) requires that tobacco products are regulated by Directive 2001/37/EC through testing and verification of results on the basis of standards developed by the International Organization for Standardization (ISO). In 2007, the European Commission provided guidance to EU Member States by issuing criteria for competent laboratories which includes accreditation to ISO 17025:2005. Another criterion requires regular laboratory participation in collaborative studies that predict the measurement tolerance that must be observed to conclude that test results on any particular product are different. However, differences will always occur when comparing overall data across products between different laboratories. A forum for technical discussion between laboratories testing products as they are manufactured and a Government appointed verification laboratory gives transparency, ensures consistency and reduces apparent compliance issues to the benefit of all parties. More than 30years ago, such a forum was set up in the UK that continued until 2007 and will be described in this document. Anticipating further testing requirements in future product regulation as proposed by the Framework Convention on Tobacco Control, cooperation between accredited laboratories, whether for testing or verification, should be established to share know-how, to ensure a standardised level of quality and to offer competent technical dialogue in the best interest of regulators and manufacturers alike. Copyright 2009 Elsevier Inc. All rights reserved.
Total laboratory automation: Do stat tests still matter?
Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro
2017-07-01
During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Maniatis, Georgios
2017-04-01
Fluvial sediment transport is controlled by hydraulics, sediment properties and arrangement, and flow history across a range of time scales. One reference frame descriptions (Eulerian or Lagrangian) yield useful results but restrict the theoretical understanding of the process as differences between the two phases (liquid and solid) are not explicitly accounted. Recently, affordable Inertial Measurement Units (IMUs) that can be embedded in coarse (100 mm diameter scale) natural or artificial particles became available. These sensors are subjected to technical limitations when deployed for natural sediment transport. However, they give us the ability to measure for the first time the inertial dynamics (acceleration and angular velocity) of moving sediment grains under fluvial transport. Theoretically, the assumption of an ideal (IMU), rigidly attached at the centre of the mass of a sediment particle can simplify greatly the derivation of a general Eulerian-Lagrangian (E-L) model. This approach accounts for inertial characteristics of particles in a Lagrangian (particle fixed) frame, and for the hydrodynamics in an independent Eulerian frame. Simplified versions of the E-L model have been evaluated in laboratory experiments using real-IMUs [Maniatis et. al 2015]. Here, experimental results are presented relevant to the evaluation of the complete E-L model. Artificial particles were deployed in a series of laboratory and field experiments. The particles are equipped with an IMU capable of recording acceleration at ± 400 g and angular velocities at ± 1200 rads/sec ranges. The sampling frequency ranges from 50 to 200 Hz for the total IMU measurement. Two sets of laboratory experiments were conducted in a 0.9m wide laboratory flume. The first is a set of entrainment threshold experiments using two artificial particles: a spherical of D=90mm (A) and an ellipsoid with axes of 100, 70 and 30 mm (B). For the second set of experiments, a spherical artificial enclosure of D=75 mm (C) was released to roll freely in a (> threshold for entrainment) flow and over surfaces of different roughness. Finally, the coarser spherical and elliptical sensor- assemblies (A and B) were deployed in a steep mountain stream during active sediment transport flow conditions. The results include the calculation of the inertial acceleration, the instantaneous particle velocity and the total kinetic energy of the mobile particle (including the rotational component using gyroscope measurements). The comparison of the field deployments with the laboratory experiments suggests that E-L model can be generalised from laboratory to natural conditions. Overall, the inertia of individual coarse particles is a statistically significant effect for all the modes of sediment transport (entrainment, translation, deposition) in both natural and laboratory regimes. Maniatis et. al 2015: "Calculating the Explicit Probability of Entrainment Based on Inertial Acceleration Measurements", J. Hydraulic Engineering, 04016097
Song, Liqiong; Sun, Shipeng; Li, Bo; Pan, Yang; Li, Wenli; Zhang, Kuo; Li, Jinming
2011-10-01
Three armored RNAs (virus-like particles [VLPs]) containing target sequences from enterovirus 71 (EV71) and coxsackievirus A16 (CA16) and a pan-enterovirus (pan-EV) sequence were constructed and used in an external quality assessment (EQA) to determine the performance of laboratories in the detection of EV71 and CA16. The EQA panel, which consisted of 20 samples, including 14 positive samples with different concentrations of EV and either EV71 or CA16 armored RNAs, 2 samples with all 3 armored RNAs, and 4 negative-control samples (NaN(3)-preserved minimal essential medium [MEM] without VLPs), was distributed to 54 laboratories that perform molecular diagnosis of hand, foot, and mouth disease (HFMD) virus infections. A total of 41 data sets from 41 participants were returned; 5 (12.2%) were generated using conventional in-house reverse transcription-PCR (RT-PCR) assays, and 36 (87.8%) were generated using commercial real-time RT-PCR assays. Performance assessments of laboratories differed; 12 (29.3%) showed a need for improvement. Surprisingly, 4 laboratories were unable to detect EV71 RNA in any samples, even those containing the highest concentration of 10(7) IU/ml. Furthermore, the detection sensitivity for EV71 among all laboratories (82.1%) was substantially lower than that for EV (97.4%) or CA16 (95.1%). Overall, the results of the present study indicate that EQA should be performed periodically to help laboratories monitor their ability to detect HFMD viruses and to improve the comparability of results from different laboratories.
Song, Liqiong; Sun, Shipeng; Li, Bo; Pan, Yang; Li, Wenli; Zhang, Kuo; Li, Jinming
2011-01-01
Three armored RNAs (virus-like particles [VLPs]) containing target sequences from enterovirus 71 (EV71) and coxsackievirus A16 (CA16) and a pan-enterovirus (pan-EV) sequence were constructed and used in an external quality assessment (EQA) to determine the performance of laboratories in the detection of EV71 and CA16. The EQA panel, which consisted of 20 samples, including 14 positive samples with different concentrations of EV and either EV71 or CA16 armored RNAs, 2 samples with all 3 armored RNAs, and 4 negative-control samples (NaN3-preserved minimal essential medium [MEM] without VLPs), was distributed to 54 laboratories that perform molecular diagnosis of hand, foot, and mouth disease (HFMD) virus infections. A total of 41 data sets from 41 participants were returned; 5 (12.2%) were generated using conventional in-house reverse transcription-PCR (RT-PCR) assays, and 36 (87.8%) were generated using commercial real-time RT-PCR assays. Performance assessments of laboratories differed; 12 (29.3%) showed a need for improvement. Surprisingly, 4 laboratories were unable to detect EV71 RNA in any samples, even those containing the highest concentration of 107 IU/ml. Furthermore, the detection sensitivity for EV71 among all laboratories (82.1%) was substantially lower than that for EV (97.4%) or CA16 (95.1%). Overall, the results of the present study indicate that EQA should be performed periodically to help laboratories monitor their ability to detect HFMD viruses and to improve the comparability of results from different laboratories. PMID:21865426
Risch, Martin; Nydegger, Urs; Risch, Lorenz
2017-01-01
In clinical practice, laboratory results are often important for making diagnostic, therapeutic, and prognostic decisions. Interpreting individual results relies on accurate reference intervals and decision limits. Despite the considerable amount of resources in clinical medicine spent on elderly patients, accurate reference intervals for the elderly are rarely available. The SENIORLAB study set out to determine reference intervals in the elderly by investigating a large variety of laboratory parameters in clinical chemistry, hematology, and immunology. The SENIORLAB study is an observational, prospective cohort study. Subjectively healthy residents of Switzerland aged 60 years and older were included for baseline examination (n = 1467), where anthropometric measurements were taken, medical history was reviewed, and a fasting blood sample was drawn under optimal preanalytical conditions. More than 110 laboratory parameters were measured, and a biobank was set up. The study participants are followed up every 3 to 5 years for quality of life, morbidity, and mortality. The primary aim is to evaluate different laboratory parameters at age-related reference intervals. The secondary aims of this study include the following: identify associations between different parameters, identify diagnostic characteristics to diagnose different circumstances, identify the prevalence of occult disease in subjectively healthy individuals, and identify the prognostic factors for the investigated outcomes, including mortality. To obtain better grounds to justify clinical decisions, specific reference intervals for laboratory parameters of the elderly are needed. Reference intervals are obtained from healthy individuals. A major obstacle when obtaining reference intervals in the elderly is the definition of health in seniors because individuals without any medical condition and any medication are rare in older adulthood. Reference intervals obtained from such individuals cannot be considered representative for seniors in a status of age-specific normal health. In addition to the established methods for determining reference intervals, this longitudinal study utilizes a unique approach, in that survival and long-term well-being are taken as indicators of health in seniors. This approach is expected to provide robust and representative reference intervals that are obtained from an adequate reference population and not a collective of highly selected individuals. The present study was registered under International Standard Randomized Controlled Trial Number registry: ISRCTN53778569.
Wilby, Kyle John; Nasr, Ziad Ghantous
2016-11-01
Background: Professional responsibilities are guided by laws and ethics that must be introduced and mastered within pharmaceutical sciences training. Instructional design to teaching typically introduces concepts in a traditional didactic approach and requires student memorization prior to application within practice settings. Additionally, many centers rely on best practices from abroad, due to lack of locally published laws and guidance documents. Objectives: The aim of this paper was to summarize and critically evaluate a professional skills laboratory designed to enhance learning through diversity in instructional methods relating to pharmacy law and best practices regarding narcotics, controlled medications, and benzodiazepines. Setting: This study took place within the Professional Skills Laboratory at the College of Pharmacy at Qatar University. Method: A total of 25 students participated in a redesigned laboratory session administered by a faculty member, clinical lecturer, teaching assistant, and a professional skills laboratory technician. The laboratory consisted of eight independent stations that students rotated during the 3-h session. Stations were highly interactive in nature and were designed using non-traditional approaches such as charades, role-plays, and reflective drawings. All stations attempted to have students relate learned concepts to practice within Qatar. Main outcome measures: Student perceptions of the laboratory were measured on a post-questionnaire and were summarized descriptively. Using reflection and consensus techniques, two faculty members completed a SWOC (Strengths, Weaknesses, Opportunities, and Challenges) analysis in preparation for future cycles. Results: 100% (25/25) of students somewhat or strongly agreed that their knowledge regarding laws and best practices increased and that their learning experience was enhanced by a mixed-methods approach. A total of 96% (24/25) of students stated that the mixed-methods instructional approach should be continued in the future. The SWOC analysis identified the mixed methods approach and student feedback as strengths and opportunities, while resource shortages and lack of impact assessment were identified as weaknesses and challenges. Conclusion: Creative redesign of instructional methods pertaining to law and best practices was effective to achieve positive student perceptions regarding instructional methods and learning. Future cycles should include rigorous assessment methods to evaluate impact on student learning and practice.
Real-time contaminant sensing and control in civil infrastructure systems
NASA Astrophysics Data System (ADS)
Rimer, Sara; Katopodes, Nikolaos
2014-11-01
A laboratory-scale prototype has been designed and implemented to test the feasibility of real-time contaminant sensing and control in civil infrastructure systems. A blower wind tunnel is the basis of the prototype design, with propylene glycol smoke as the ``contaminant.'' A camera sensor and compressed-air vacuum nozzle system is set up at the test section portion of the prototype to visually sense and then control the contaminant; a real-time controller is programmed to read in data from the camera sensor and administer pressure to regulators controlling the compressed air operating the vacuum nozzles. A computational fluid dynamics model is being integrated in with this prototype to inform the correct pressure to supply to the regulators in order to optimally control the contaminant's removal from the prototype. The performance of the prototype has been evaluated against the computational fluid dynamics model and is discussed in this presentation. Furthermore, the initial performance of the sensor-control system implemented in the test section of the prototype is discussed. NSF-CMMI 0856438.
Malentacchi, Francesca; Mancini, Irene; Brandslund, Ivan; Vermeersch, Pieter; Schwab, Matthias; Marc, Janja; van Schaik, Ron H N; Siest, Gerard; Theodorsson, Elvar; Pazzagli, Mario; Di Resta, Chiara
2015-06-01
Developments in "-omics" are creating a paradigm shift in laboratory medicine leading to personalized medicine. This allows the increase in diagnostics and therapeutics focused on individuals rather than populations. In order to investigate whether laboratory medicine is ready to play a key role in the integration of personalized medicine in routine health care and set the state-of-the-art knowledge about personalized medicine and laboratory medicine in Europe, a questionnaire was constructed under the auspices of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and the European Society of Pharmacogenomics and Personalised Therapy (ESPT). The answers of the participating laboratory medicine professionals indicate that they are aware that personalized medicine can represent a new and promising health model, and that laboratory medicine should play a key role in supporting the implementation of personalized medicine in the clinical setting. Participants think that the current organization of laboratory medicine needs additional/relevant implementations such as (i) new technological facilities in -omics; (ii) additional training for the current personnel focused on the new methodologies; (iii) incorporation in the laboratory of new competencies in data interpretation and counseling; and (iv) cooperation and collaboration among professionals of different disciplines to integrate information according to a personalized medicine approach.
Díez-Delgado, I; Rodríguez, O; Boadella, M; Garrido, J M; Sevilla, I A; Bezos, J; Juste, R; Domínguez, L; Gortázar, C
2017-10-01
In 2012, a wild boar (Sus scrofa) tuberculosis (TB) control programme was set up in a wild boar farm by means of intramuscular (IM) vaccination with a heat-inactivated Mycobacterium bovis vaccine (IV). The goal was to assess safety and efficacy of the parenterally administered IV in a large farm setting with natural M. bovis circulation. Based on preceding results under laboratory conditions, we hypothesized that vaccinated piglets would show smaller scores of TB-compatible lesions (TBCL) than unvaccinated controls. After vaccination, no adverse reactions were detected by visual inspection or at post-mortem examination (n = 668 and 97, respectively). Post-mortem data on TBCL were available for 97 vaccinated wild boar and 182 controls. The observed TBCL prevalence was 4.1% (95% CI = 0.2-8%) and 12.1% (95% CI = 7.1-17.1%) for vaccinated and control wild boar, respectively (P < 0.05). Among those animals with TBCL, no difference in the mean lesion score was found (P > 0.05). The results show that IV administered intramuscularly to wild boar piglets is safe and protects vaccinated individuals (66% reduction in TBCL prevalence) against natural challenge in a low-prevalence setting. In a context of increasing TB prevalence in wild boar in Mediterranean habitats, vaccination achieved a progressive though slow decline in lesion prevalence since the onset of the vaccination scheme. Hence, vaccination might contribute, along with other tools, to TB control in wild boar and in pigs. © 2016 Blackwell Verlag GmbH.