Sample records for controlled repeated measures

  1. Effects of repeated Valsalva maneuver straining on cardiac and vasoconstrictive baroreflex responses

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.; Ratliff, Duane A.; Doerr, Donald F.; Ludwig, David A.; Muniz, Gary W.; Benedetti, Erik; Chavarria, Jose; Koreen, Susan; Nguyen, Claude; Wang, Jeff

    2003-01-01

    INTRODUCTION: We hypothesized that repeated respiratory straining maneuvers (repeated SM) designed to elevate arterial BPs (arterial baroreceptor loading) would acutely increase baroreflex responses. METHODS: We tested this hypothesis by measuring cardiac baroreflex responses to carotid baroreceptor stimulation (neck pressures), and changes in heart rate and diastolic BP after reductions in BP induced by a 15-s Valsalva maneuver in 10 female and 10 male subjects at 1, 3, 6, and 24 h after performing repeated SM. Baroreflex responses were also measured in each subject at 1, 3, 6, and 24 h at the same time on a separate day without repeated SM (control) in a randomized, counter-balanced cross-over experimental design. RESULTS: There was no statistical difference in carotid-cardiac and peripheral vascular baroreflex responses measured across time following repeated SM compared with the control condition. Integrated cardiac baroreflex response (deltaHR/ deltaSBP) measured during performance of a Valsalva maneuver was increased by approximately 50% to 1.1 +/- 0.2 bpm x mm Hg(-1) at 1 h and 1.0 +/- 0.1 bpm x mm Hg(-1) at 3 h following repeated SM compared with the control condition (0.7 +/- 0.1 bpm x mm Hg(-1) at both 1 and 3 h, respectively). However, integrated cardiac baroreflex response after repeated SM returned to control levels at 6 and 24 h after training. These responses did not differ between men and women. CONCLUSIONS: Our results are consistent with the notion that arterial baroreceptor loading induced by repeated SM increased aortic, but not carotid, cardiac baroreflex responses for as long as 3 h after repeated SM. We conclude that repeated SM increases cardiac baroreflex responsiveness which may provide patients, astronauts, and high-performance aircraft pilots with protection from development of orthostatic hypotension.

  2. Simulated Keratometry Repeatability in Subjects with & without Down Syndrome

    PubMed Central

    Ravikumar, Ayeswarya; Marsack, Jason D.; Benoit, Julia S.; Anderson, Heather A.

    2016-01-01

    Purpose To assess the repeatability of simulated keratometry measures obtained with Zeiss Atlas topography for subjects with and without Down syndrome (DS). Methods Corneal topography was attempted on 140 subjects with DS and 138 controls (aged 7 to 59 years). Subjects who had at least 3 measures in each eye were included in analysis (DS: n=140 eyes (70 subjects) and controls: n=264 eyes (132 subjects)). For each measurement the steep corneal power (K), corneal astigmatism, flat K orientation, power vector representation of astigmatism (J0, J45), and astigmatic dioptric difference were determined for each measurement (collectively termed keratometry values here). For flat K orientation comparisons, only eyes with >0.50 DC of astigmatism were included (DS: n=131 eyes (68 subjects) and control: n=217 eyes (119 subjects)). Repeatability was assessed using 1) group mean variability (average standard deviation (SD) across subjects), 2) coefficient of repeatability (COR) 3) coefficient of variation (COV), and 4) intraclass correlation coefficient (ICC). Results The keratometry values showed good repeatability as evidenced by low group mean variability for DS vs control eyes (≤0.26D vs ≤0.09D for all dioptric values; 4.51° vs 3.16° for flat K orientation); however, the group mean variability was significantly higher in DS eyes than control eyes for all parameters (p≤0.03). On average, group mean variability was 2.5× greater in the DS eyes compared to control eyes across the keratometry values. Other metrics of repeatability also indicated good repeatability for both populations for each keratometry value, although repeatability was always better in the control eyes. Conclusions DS eyes showed more variability (on average: 2.5×) compared to controls for all keratometry values. Although differences were statistically significant, on average 91% of DS eyes had variability ≤0.50D for steep K and astigmatism, and 75% of DS eyes had variability ≤5 degrees for flat K orientation. PMID:27741083

  3. Repeatability of Monocular Acuity Testing in Adults with and without Down Syndrome.

    PubMed

    Ravikumar, Ayeswarya; Benoit, Julia S; Morrison, Kelsie B; Marsack, Jason D; Anderson, Heather A

    2018-03-01

    Individuals with Down syndrome may experience greater difficulty reliably performing visual acuity (VA) tests because of intellectual disability and limitations in visual quality. This study evaluated the repeatability of acuity (Bailey-Lovie [BL] and HOTV) in subjects with and without Down syndrome. High-contrast VA was measured in both eyes of 30 subjects with Down syndrome (mean, 30 years; range, 18 to 50 years) and 24 control subjects without Down syndrome (mean, 29 years; range, 18 to 50 years). In the Down syndrome group, 23 subjects performed BL, and 7 subjects performed HOTV. All control subjects performed both BL and HOTV, but for HOTV analysis, only seven age-matched control subjects were included. For each eye, subjects performed VA three times on different charts (computer controlled, single-line display) until five total letters were missed on each chart. A repeated-measure ANOVA was used to compare the acuity measures between groups. The average logMAR VA for subjects with Down syndrome was approximately six lines worse than the control subjects (BL: Down syndrome = right eye: 0.51 ± 0.16, left eye: 0.53 ± 0.18; control = right eye: -0.06 ± 0.06, left eye: -0.06 ± 0.08, P < .0001; HOTV: Down syndrome = right eye: 0.47 ± 0.19, left eye: 0.46 ± 0.16; control: right eye = -0.11 ± 0.09, left eye: -0.07 ± 0.07, P < .001). Bailey-Lovie VA repeatability (1.96 * Sw * √2) was 0.13 logMAR (6.5 letters) for Down syndrome and 0.09 logMAR (4.5 letters) for control subjects. HOTV VA repeatability was 0.16 logMAR (eight letters) for both Down syndrome and control subjects. Despite poorer acuity in individuals with Down syndrome, repeatability of VA measurements was comparable to control subjects for both BL and HOTV techniques.

  4. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    PubMed

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  5. The Case for Use of Simple Difference Scores to Test the Significance of Differences in Mean Rates of Change in Controlled Repeated Measurements Designs

    ERIC Educational Resources Information Center

    Overall, John E.; Tonidandel, Scott

    2010-01-01

    A previous Monte Carlo study examined the relative powers of several simple and more complex procedures for testing the significance of difference in mean rates of change in a controlled, longitudinal, treatment evaluation study. Results revealed that the relative powers depended on the correlation structure of the simulated repeated measurements.…

  6. Proactive behavior, but not inhibitory control, predicts repeated innovation by spotted hyenas tested with a multi-access box.

    PubMed

    Johnson-Ulrich, Lily; Johnson-Ulrich, Zoe; Holekamp, Kay

    2018-05-01

    Innovation is widely linked to cognitive ability, brain size, and adaptation to novel conditions. However, successful innovation appears to be influenced by both cognitive factors, such as inhibitory control, and non-cognitive behavioral traits. We used a multi-access box (MAB) paradigm to measure repeated innovation, the number of unique innovations learned across trials, by 10 captive spotted hyenas (Crocuta crocuta). Spotted hyenas are highly innovative in captivity and also display striking variation in behavioral traits, making them good model organisms for examining the relationship between innovation and other behavioral traits. We measured persistence, motor diversity, motivation, activity, efficiency, inhibitory control, and neophobia demonstrated by hyenas while interacting with the MAB. We also independently assessed inhibitory control with a detour cylinder task. Most hyenas were able to solve the MAB at least once, but only four hyenas satisfied learning criteria for all four possible solutions. Interestingly, neither measure of inhibitory control predicted repeated innovation. Instead, repeated innovation was predicted by a proactive syndrome of behavioral traits that included high persistence, high motor diversity, high activity and low neophobia. Our results suggest that this proactive behavioral syndrome may be more important than inhibitory control for successful innovation with the MAB by members of this species.

  7. Development and Characterization of a Low-Pressure Calibration System for Hypersonic Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Green, Del L.; Everhart, Joel L.; Rhode, Matthew N.

    2004-01-01

    Minimization of uncertainty is essential for accurate ESP measurements at very low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources requires a well defined and controlled calibration method. A calibration system has been constructed and environmental control software developed to control experimentation to eliminate human induced error sources. The initial stability study of the calibration system shows a high degree of measurement accuracy and precision in temperature and pressure control. Control manometer drift and reference pressure instabilities induce uncertainty into the repeatability of voltage responses measured from the PSI System 8400 between calibrations. Methods of improving repeatability are possible through software programming and further experimentation.

  8. An interdisciplinary school project using a Nintendo Wii controller for measuring car speed

    NASA Astrophysics Data System (ADS)

    Hansen, Nils Kristian; Mitchell, James Robert

    2013-03-01

    This work examines the feasibility of employing a Nintendo Wii game controller for measuring car speed in an interdisciplinary school project. It discusses the physical characteristics of the controller and of vehicle headlights. It suggests how an experiment may be linked to topics in mathematics, statistics, physics and computer science. An algorithm for calculating speed from repeated recordings of car headlights is provided. Finally the results of repeated experiments with an approaching car are provided.

  9. Angle performance on optima MDxt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David, Jonathan; Kamenitsa, Dennis

    2012-11-06

    Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightlymore » tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).« less

  10. Social Stories: Mechanisms of Effectiveness in Increasing Game Play Skills in Children Diagnosed with Autism Spectrum Disorder Using a Pretest Posttest Repeated Measures Randomized Control Group Design

    ERIC Educational Resources Information Center

    Quirmbach, Linda M.; Lincoln, Alan J.; Feinberg-Gizzo, Monica J.; Ingersoll, Brooke R.; Andrews, Siri M.

    2009-01-01

    An increasing body of literature has indicated that social stories are an effective way to teach individuals diagnosed with autism appropriate social behavior. This study compared two formats of a social story targeting the improvement of social skills during game play using a pretest posttest repeated measures randomized control group design. A…

  11. Testing Multiple Outcomes in Repeated Measures Designs

    ERIC Educational Resources Information Center

    Lix, Lisa M.; Sajobi, Tolulope

    2010-01-01

    This study investigates procedures for controlling the familywise error rate (FWR) when testing hypotheses about multiple, correlated outcome variables in repeated measures (RM) designs. A content analysis of RM research articles published in 4 psychology journals revealed that 3 quarters of studies tested hypotheses about 2 or more outcome…

  12. [A case-control study of factors associated with repeat teen pregnancy based on a sample from a university maternity hospital].

    PubMed

    Silva, Andréa de Albuquerque Arruda; Coutinho, Isabela C; Katz, Leila; Souza, Alex Sandro Rolland

    2013-03-01

    Repeat teen pregnancy is a frequent issue and is considered an aggravating factor for increased maternal and fetal morbidity and social problems. The aim of the study was to identify factors associated with repeat teen pregnancy. A case-control study was conducted in 90 postpartum adolescents with more than one pregnancy (cases) and 90 adult women with a history of only one pregnancy during adolescence (controls). Statistical analysis used hierarchical logistic regression with 5% significance. Early sexual initiation (< 15 years), early age at first pregnancy (< 16 years), not raising the children themselves, and low family income (< one minimum wage) were associated with repeat teenage pregnancy, while partner change was inversely associated. Repeat teen pregnancy was mainly associated with reproductive and socioeconomic factors. Partner change appeared as a protective factor. Measures should be adopted during the postpartum period of teenage mothers in order to avoid repeat pregnancy.

  13. Langley Wind Tunnel Data Quality Assurance-Check Standard Results

    NASA Technical Reports Server (NTRS)

    Hemsch, Michael J.; Grubb, John P.; Krieger, William B.; Cler, Daniel L.

    2000-01-01

    A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.

  14. Self-Control and Impulsivity in Children: Multiple Behavioral Measures

    ERIC Educational Resources Information Center

    Forzano, L. B.; Michels, Jennifer L.; Carapella, R. K.; Conway, Patrick; Chelonis, J. J.

    2011-01-01

    The present experiment investigated the relationship between laboratory measures of self-control and delay of gratification in children and explored several other factors that may influence self-control. In the self-control paradigm, 30 four-year-old children repeatedly chose between three reinforcers received after a delay and one reinforcer…

  15. Contact Electrification of Individual Dielectric Microparticles Measured by Optical Tweezers in Air.

    PubMed

    Park, Haesung; LeBrun, Thomas W

    2016-12-21

    We measure charging of single dielectric microparticles after interaction with a glass substrate using optical tweezers to control the particle, measure its charge with a sensitivity of a few electrons, and precisely contact the particle with the substrate. Polystyrene (PS) microparticles adhered to the substrate can be selected based on size, shape, or optical properties and repeatedly loaded into the optical trap using a piezoelectric (PZT) transducer. Separation from the substrate leads to charge transfer through contact electrification. The charge on the trapped microparticles is measured from the response of the particle motion to a step excitation of a uniform electric field. The particle is then placed onto a target location of the substrate in a controlled manner. Thus, the triboelectric charging profile of the selected PS microparticle can be measured and controlled through repeated cycles of trap loading followed by charge measurement. Reversible optical trap loading and manipulation of the selected particle leads to new capabilities to study and control successive and small changes in surface interactions.

  16. On the repeated measures designs and sample sizes for randomized controlled trials.

    PubMed

    Tango, Toshiro

    2016-04-01

    For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Repeatability of intravital capillaroscopic measurement of capillary density.

    PubMed

    Lamah, M; Chaudhry, H; Mortimer, P S; Dormandy, J A

    1996-01-01

    The reliability of intravital capillaroscopy for determining capillary density (CD) of skin has been questioned because it depends upon the variability of the measuring process and subjective interpretation of data as well as the intrinsic heterogeneity of capillary spacing. The aim of this study was to assess the repeatability of a standardised method for measuring CD of the skin of the dorsum of foot. In each of 30 subjects (10 controls and 20 patients with peripheral vascular disease), the foot was systematically mapped by examining 20 sites on the dorsum of foot and 2 sites on each toe, using white light (native) videomicroscopy at 40 x magnification. Off-line analysis of videoprints was then undertaken to determine CD at each site, by counting capillaries within areas of acceptable photographic quality only, having first defined the criteria for counting capillaries. The mean values were then calculated and taken to represent the CD of the foot or toes. Repeatability of the measuring equipment was first assessed by noting the presence or absence of each corresponding capillary in 2 prints, taken at intervals of hours or days (in 10 subjects) or months (in 2 patients), of an identical area of skin which was marked by a microtattoo on the first occasion. On average, 95% of corresponding capillaries were identified in both prints (from controls and patients), thus implying little intrinsic temporal variation of capillary anatomy as well as excellent repeatability of the measuring equipment. Repeatability of data analysis was assessed by the same observer reading the same 20 prints in a blinded manner on three separate occasions (intraobserver repeatability), and 2 observers reading the same 24 prints (interobserver repeatability). The mean coefficient of intraobserver variation of CD estimate was 5.6% and the interobserver correlation coefficient was 0.94. Finally, overall repeatability of the method was assessed by repeating the procedure on a subsequent occasion (mean time interval of 5 days) in 10 subjects. The rate of agreement in mean CD between the two procedures [defined as 100- (difference between the two measurements/mean of the two measurements) x 100]% ranged from 86.4 to 97.1% (mean 93.5%). Thus using the above methodological technique, native capillaroscopy can be reliably used to determine CD of the dorsum of foot in comparing patient subgroups, as well as in longitudinal studies.

  18. Mission design for NISAR repeat-pass Interferometric SAR

    NASA Astrophysics Data System (ADS)

    Alvarez-Salazar, Oscar; Hatch, Sara; Rocca, Jennifer; Rosen, Paul; Shaffer, Scott; Shen, Yuhsyen; Sweetser, Theodore; Xaypraseuth, Peter

    2014-10-01

    The proposed spaceborne NASA-ISRO SAR (NISAR) mission would use the repeat-pass interferometric Synthetic Aperture Radar (InSAR) technique to measure the changing shape of Earth's surface at the centimeter scale in support of investigations in solid Earth and cryospheric sciences. Repeat-pass InSAR relies on multiple SAR observations acquired from nearly identical positions of the spacecraft as seen from the ground. Consequently, there are tight constraints on the repeatability of the orbit, and given the narrow field of view of the radar antenna beam, on the repeatability of the beam pointing. The quality and accuracy of the InSAR data depend on highly precise control of both orbital position and observatory pointing throughout the science observation life of the mission. This paper describes preliminary NISAR requirements and rationale for orbit repeatability and attitude control in order to meet science requirements. A preliminary error budget allocation and an implementation approach to meet these allocations are also discussed.

  19. Measurement system with high accuracy for laser beam quality.

    PubMed

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  20. Is ADHD a Risk Factor for High School Dropout? A Controlled Study.

    PubMed

    Fried, Ronna; Petty, Carter; Faraone, Stephen V; Hyder, Laran L; Day, Helen; Biederman, Joseph

    2016-05-01

    This study examined whether ADHD was an independent contributor to grade retention when adjusting for IQ, learning disorders, and social class. Outcome data was from participants in studies at Massachusetts General Hospital (n= 404 ADHD,n= 349 controls) who underwent psychiatric interviews, socioeconomic status measures, and IQ testing. 28% of individuals with ADHD repeated a grade compared with 7% of controls (p< .001). Among participants with ADHD, social class, and IQ were significant predictors of high school dropout or repeated grade. An interaction effect of ADHD and gender was also found with females with ADHD having a higher risk ratio for repeated grade/dropout compared with males with ADHD. Participants with ADHD were significantly more likely to repeat a grade, adjusting for all other variables indicating the critical importance of early identification of ADHD to help mitigate adverse educational outcomes. © The Author(s) 2013.

  1. Flexible Magnets Are Not Effective in Decreasing Pain Perception and Recovery Time After Muscle Microinjury

    PubMed Central

    Borsa, Paul A.; Liggett, Charles L.

    1998-01-01

    Objective: To assess the therapeutic effects of flexible magnets on pain perception, intramuscular swelling, range of motion, and muscular strength in individuals with a muscle microinjury. Design and Setting: This experiment was a single-blind, placebo study using a repeated-measures design. Subjects performed an intense exercise protocol to induce a muscle microinjury. After pretreatment measurements were recorded, subjects were randomly assigned to an experimental (magnet), placebo (imitation magnet), or control (no magnet) group. Posttreatment measurements were repeated at 24, 48, and 72 hours. Subjects: Forty-five healthy subjects participated in the study. Measurements: Subjects were measured repeatedly for pain perception, upper arm girth, range of motion, and static force production. Four separate univariate analyses of variances were used to reveal statistically significant mean (±SD) differences between variables over time. Interaction effects were analyzed using Scheffe post hoc analysis. Results: Analysis of variance revealed no statistically significant (P > .05) mean differences between conditions for any dependent pretreatment and posttreatment measurements. No significant interaction effects were demonstrated between conditions and times. Conclusions: No significant therapeutic effects on pain control and muscular dysfunction were observed in subjects wearing flexible magnets. ImagesFig 2.Fig 3. PMID:16558503

  2. Differences in salivary habituation to palatable foods in bulimia nervosa patients and controls.

    PubMed

    Wisniewski, L; Epstein, L H; Marcus, M D; Kaye, W

    1997-01-01

    Bulimia nervosa (BN) patients have been shown to experience anomalous responses to food and food cues. We investigated the response to food over time by presenting repeated food cues and measuring changes in physiological (ie, salivation) and subjective responses. Subjects were 18 BN women and 18 matched control women. Two palatable food stimuli, regular or frozen yogurt, that varied in macronutrient composition but had similar sensory characteristics, were presented to subjects repeatedly during a laboratory session. After two baseline salivation measures, subjects were presented with eight trials of one of the two yogurts. On Trial 9 a lemon juice dishabituator was presented, with the yogurt stimulus presented again at Trial 10. We found that control subjects had decreased salivation after repeated food presentations. In comparison, BN subjects failed to show a decrease in salivation. The desire to binge increased over trials for the BN subjects, but remained stable for normals. These data suggest that salivary habituation may be abnormal in BN patients.

  3. A study of the Huntington's disease associated trinucleotide repeat in the Scottish population.

    PubMed Central

    Barron, L H; Warner, J P; Porteous, M; Holloway, S; Simpson, S; Davidson, R; Brock, D J

    1993-01-01

    Accurate measurements of a specific CAG repeat sequence in the Huntington's disease (HD) gene in 337 HD patients and 229 normal controls from the Scottish population showed a range from 35 to 62 repeats in affected subjects and eight to 33 in normal subjects. A link between early onset of symptoms and very high repeat number was seen. For HD patients with the most common affected allele sizes (39 to 42 repeats) absolute repeat size was a poor index for the age at onset of symptoms. There was variability in the transmitted repeat size for both sexes in the HD size range. We observed a significant increase of repeat size for paternal transmission of the disease and greater instability for paternally transmitted CAG repeats in the HD size range. Images PMID:8133495

  4. Bioimpedance for the spot measurement of tissue density

    NASA Astrophysics Data System (ADS)

    Dylke, E. S.; Ward, L. C.; Stannard, C.; Leigh, A.; Kilbreath, S. L.

    2013-04-01

    Long-standing lymphoedema is characterised by tissues changes which are currently not detectable using bioimpedance spectroscopy. It has been suggested that a combination of bipolar and tetrapolar measurements may be used to detect these tissues changes for a single site in the transverse direction. This was technique was trialled in a group of control participants with no history of lymphoedema or recent upper limb trauma. Repeated spot measurements were done without removal of electrodes to determine biological variability as well as with removal of electrodes to determine technical reproducibility. The inter-limb spot ratio of the controls was then compared to that of a number of women previously diagnosed with secondary lymphoedema in the forearm. Biological variability was not found to greatly influence repeated measures but only moderate technical reliability was found despite excellent co-efficient of variation for the majority of the measurements. A difference was seen between those with more severe swelling and the controls. This novel technique shows promise in detecting tissue changes associated with long-standing lymphoedema.

  5. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    PubMed Central

    Mortazavi, SMJ; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, AR

    2014-01-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test). To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors. PMID:25505778

  6. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors.

    PubMed

    Mortazavi, Smj; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, Ar

    2014-09-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test). To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors.

  7. Repeatability of quantitative sensory testing in healthy cats in a clinical setting with comparison to cats with osteoarthritis.

    PubMed

    Addison, Elena S; Clements, Dylan N

    2017-12-01

    Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.

  8. High-precision radius automatic measurement using laser differential confocal technology

    NASA Astrophysics Data System (ADS)

    Jiang, Hongwei; Zhao, Weiqian; Yang, Jiamiao; Guo, Yongkui; Xiao, Yang

    2015-02-01

    A high precision radius automatic measurement method using laser differential confocal technology is proposed. Based on the property of an axial intensity curve that the null point precisely corresponds to the focus of the objective and the bipolar property, the method uses the composite PID (proportional-integral-derivative) control to ensure the steady movement of the motor for process of quick-trigger scanning, and uses least-squares linear fitting to obtain the position of the cat-eye and confocal positions, then calculates the radius of curvature of lens. By setting the number of measure times, precision auto-repeat measurement of the radius of curvature is achieved. The experiment indicates that the method has the measurement accuracy of better than 2 ppm, and the measuring repeatability is better than 0.05 μm. In comparison with the existing manual-single measurement, this method has a high measurement precision, a strong environment anti-interference capability, a better measuring repeatability which is only tenth of former's.

  9. The Effects of Elbow Bracing on Medial Elbow Joint Space Gapping Associated With Repetitive Throwing in High School Baseball Players

    PubMed Central

    Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Takei, Keiichi; Yamamoto, Mitsuru

    2017-01-01

    Background: Throwing athletes risk medial elbow injury from extreme valgus stress generated across the medial elbow during throwing. Braces have been developed to protect the elbow joint; however, no previous study has investigated the effects of elbow bracing on medial elbow joint space gapping associated with repetitive throwing. Hypothesis/Purpose: The purpose of this study was to investigate the effects of elbow bracing on medial elbow joint space gapping during repetitive throwing. Our hypothesis was that an elbow brace may reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. Study Design: Controlled laboratory study. Methods: Twenty-five high school baseball players participated in this study. Each subject pitched 100 times under 2 conditions: control (without elbow brace) and elbow brace. The ulnohumeral joint space was measured ultrasonically before pitching and after every block of 20 pitches. Measurement of the ulnohumeral joint space was carried out using ultrasound with the forearm hanging by the side. Two-way repeated-measures analysis of variance and post hoc tests were used to compare ulnohumeral joint space with repeated pitching and between the elbow brace and control conditions. Results: In the control condition, ulnohumeral joint space after 60 pitches was significantly greater than that before pitching (P < .01). In contrast, in the elbow brace condition, ulnohumeral joint space was not significantly different after repeated pitching. When comparing these 2 conditions, ulnohumeral joint space in the control condition was significantly greater than that in the elbow brace condition after 60 pitches (P < .01). Conclusion: An elbow brace has the effect of preventing medial elbow joint space gapping with repeated throwing when determined ultrasonically by measuring the ulnohumeral joint space under gravity load. Clinical Relevance: An elbow brace worn during baseball pitching practice may help reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. PMID:28451622

  10. The Effects of Elbow Bracing on Medial Elbow Joint Space Gapping Associated With Repetitive Throwing in High School Baseball Players.

    PubMed

    Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Takei, Keiichi; Yamamoto, Mitsuru

    2017-04-01

    Throwing athletes risk medial elbow injury from extreme valgus stress generated across the medial elbow during throwing. Braces have been developed to protect the elbow joint; however, no previous study has investigated the effects of elbow bracing on medial elbow joint space gapping associated with repetitive throwing. The purpose of this study was to investigate the effects of elbow bracing on medial elbow joint space gapping during repetitive throwing. Our hypothesis was that an elbow brace may reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. Controlled laboratory study. Twenty-five high school baseball players participated in this study. Each subject pitched 100 times under 2 conditions: control (without elbow brace) and elbow brace. The ulnohumeral joint space was measured ultrasonically before pitching and after every block of 20 pitches. Measurement of the ulnohumeral joint space was carried out using ultrasound with the forearm hanging by the side. Two-way repeated-measures analysis of variance and post hoc tests were used to compare ulnohumeral joint space with repeated pitching and between the elbow brace and control conditions. In the control condition, ulnohumeral joint space after 60 pitches was significantly greater than that before pitching ( P < .01). In contrast, in the elbow brace condition, ulnohumeral joint space was not significantly different after repeated pitching. When comparing these 2 conditions, ulnohumeral joint space in the control condition was significantly greater than that in the elbow brace condition after 60 pitches ( P < .01). An elbow brace has the effect of preventing medial elbow joint space gapping with repeated throwing when determined ultrasonically by measuring the ulnohumeral joint space under gravity load. An elbow brace worn during baseball pitching practice may help reduce mechanical stress on the elbow by reducing medial elbow joint space gapping.

  11. Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases.

    PubMed

    Tan, Rose S; Guymer, Robyn H; Luu, Chi D

    2018-05-01

    To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowder, Stephen V.

    This document outlines a statistical framework for establishing a shelf-life program for components whose performance is measured by the value of a continuous variable such as voltage or function time. The approach applies to both single measurement devices and repeated measurement devices, although additional process control charts may be useful in the case of repeated measurements. The approach is to choose a sample size that protects the margin associated with a particular variable over the life of the component. Deviations from expected performance of the measured variable are detected prior to the complete loss of margin. This ensures the reliabilitymore » of the component over its lifetime.« less

  13. Validation of a Hartmann-Moiré wavefront sensor with large dynamic range.

    PubMed

    Wei, Xin; Van Heugten, Tony; Thibos, Larry

    2009-08-03

    Our goal was to validate the accuracy, repeatability, sensitivity, and dynamic range of a Hartmann-Moiré (HM) wavefront sensor (PixelOptics, Inc.) designed for ophthalmic applications. Testing apparatus injected a 4 mm diameter monochromatic (532 nm) beam of light into the wavefront sensor for measurement. Controlled amounts of defocus and astigmatism were introduced into the beam with calibrated spherical (-20D to + 18D) and cylindrical (-8D to + 8D) lenses. Repeatability was assessed with three repeated measurements within a 2-minute period. Correlation coefficients between mean wavefront measurements (n = 3) and expected wavefront vergence for both sphere and cylinder lenses were >0.999. For spherical lenses, the sensor was accurate to within 0.1D over the range from -20D to + 18D. For cylindrical lenses, the sensor was accurate to within 0.1D over the range from -8D to + 8D. The primary limitation to demonstrating an even larger dynamic range was the increasingly critical requirements for optical alignment. Sensitivity to small changes of vergence was constant over the instrument's full dynamic range. Repeatability of measurements for fixed condition was within 0.01D. The Hartmann-Moiré wavefront sensor measures defocus and astigmatism accurately and repeatedly with good sensitivity over a large dynamic range required for ophthalmic applications.

  14. Repeatability of in vitro measurements of the ultraviolet protection factor (UPF) by spectrophotometry with automatic sampling.

    PubMed

    Hoffmann, K; Kesners, P; Bader, A; Avermaete, A; Altmeyer, P; Gambichler, T

    2001-11-01

    Spectrophotometric assessment (in vitro) is the most established method for determining the ultraviolet protection factor (UPF) of textiles. Apart from stringent requirements for measurement precision, practical methods are required for the routine determination of the UPF. We report here spectrophotometric measurements of textiles using a newly developed autosampler. Measurement precision was evaluated under repeatable conditions. Fifteen different textiles were spectrophotometrically assessed for the determination of the UPF. Sample handling inside the spectrophotometer was performed with a computer-controlled sampling device, capable of loading and unloading a textile sample from a magazine as well as rotating the sample perpendicular to the spectrometer beam. In order to evaluate the repeatability of measurements, one sample of each textile was assessed eight times under the same conditions in the same laboratory. A mean percentage of the standard error of 1% [E(UPF)] was calculated for the UPF measurements. For UPFs >30, a significantly higher E(UPF) was found (r=0.78; P<0.001). E(UV) (3.9%) of ultraviolet A (UVA) transmission differed significantly from E(UV) (1.1 %) of ultraviolet B (UVB) transmission (P<0.05). Though a slight decrease of repeatability was observed for UVA transmission measurements and UPFs higher than 30, our data indicate a high measurement precision under repeatable conditions. In conclusion, spectrophotometric measurements of textiles with the aid of the autosampler presented have been shown to be highly practical, time saving and precise.

  15. En face Doppler total retinal blood flow measurement with 70 kHz spectral optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tan, Ou; Liu, Gangjun; Liang, Liu; Gao, Simon S.; Pechauer, Alex D.; Jia, Yali; Huang, David

    2015-06-01

    An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans (2×2 mm) obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was 45.4±6.7 μl/min for healthy control and 34.7±7.6 μl/min for glaucomatous participants (p-value=0.01). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement.

  16. Exploring Visual Selective Attention towards Novel Stimuli in Alzheimer's Disease Patients.

    PubMed

    Chau, Sarah A; Herrmann, Nathan; Eizenman, Moshe; Chung, Jonathan; Lanctôt, Krista L

    2015-01-01

    Alzheimer's disease (AD) is associated with selective attention impairments, which could contribute to cognitive and functional deficits. Selective attention can be explored through examination of novelty preference. In this study, we quantified novelty preference in AD patients by measuring visual scanning behaviour using an eye tracking paradigm. Mild-to-moderate AD patients and elderly controls viewed slides containing novel and repeated images simultaneously. The outcome measure was time spent on specific images, with novelty preference defined by greater relative fixation time (RFT) on novel versus repeated images. Cognitive status (Standardized Mini-Mental State Examination, SMMSE) and attention (Digit Span, DS) were also measured. AD patients (age 79.2 ± 6.7 years, SMMSE 22.2 ± 4.0, n = 41) and controls (age 76.2 ± 6.4 years, SMMSE 28.1 ± 2.0, n = 24) were similar in age, education and sex. Compared with controls, AD patients had lower RFT on novel than on repeated images (F1,63 = 11.18, p = 0.001). Further, reduced RFT was associated with lower scores on SMMSE (r63 = 0.288, p = 0.020) and DS (r63 = 0.269, p = 0.030). Within individuals, novelty preference was detected in 92.3% of patients and in 100% of controls. These findings suggest that novelty preference, measured by visual scanning behaviour, can differentiate cognitively healthy and impaired people and may offer a nonverbal, less cognitively demanding method of assessing selective attention.

  17. Tight calorie control in geriatric patients following hip fracture decreases complications: a randomized, controlled study.

    PubMed

    Anbar, R; Beloosesky, Y; Cohen, J; Madar, Z; Weiss, A; Theilla, M; Koren Hakim, T; Frishman, S; Singer, P

    2014-02-01

    Optimizing nutritional intake has been recommended for geriatric patients undergoing hip-fracture surgery. Whether nutritional support guided by repeated measurements of resting energy requirements (REE) improves outcomes in these patients is not known. A randomized, controlled, unblinded, prospective, cohort study comparing provision of energy with a goal determined by repeated REE measurements using indirect calorimetry, with no intervention. Oral nutritional supplements were started 24 h after surgery and the amount adjusted to make up the difference between energy received from hospital food and measured energy expenditure. 50 Geriatric patients were included in the study. Patients in the intervention group (n = 22) received significantly higher daily energy intake than the control group (n = 28) (1121.3 ± 299.0 vs. 777.1 ± 301.2 kcal, p = 0.001). This was associated with a significantly less negative cumulative energy balance (-1229.9 ± 1763 vs. -4975.5 ± 4368 kcal, p = 0.001). A significant negative correlation was found between the cumulative energy balance and total complication rate (r = -0.417, p = 0.003) as well as for length of hospital stay (r = -0.282, p = 0.049). We have demonstrated that nutritional support actively supervised by a dietician and guided by repeated measurements of REE was achievable and improved outcomes in geriatric patients following surgery for hip fractures. Clinicaltrials.gov Identifier: NCT017354435. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  18. PH Tester Gauge Repeatability and Reproducibility Study for WO3 Nanostructure Hydrothermal Growth Process

    NASA Astrophysics Data System (ADS)

    Abd Rashid, Amirul; Hayati Saad, Nor; Bien Chia Sheng, Daniel; Yee, Lee Wai

    2014-06-01

    PH value is one of the important variables for tungsten trioxide (WO3) nanostructure hydrothermal synthesis process. The morphology of the synthesized nanostructure can be properly controlled by measuring and controlling the pH value of the solution used in this facile synthesis route. Therefore, it is very crucial to ensure the gauge used for pH measurement is reliable in order to achieve the expected result. In this study, gauge repeatability and reproducibility (GR&R) method was used to assess the repeatability and reproducibility of the pH tester. Based on ANOVA method, the design of experimental metrics as well as the result of the experiment was analyzed using Minitab software. It was found that the initial GR&R value for the tester was at 17.55 % which considered as acceptable. To further improve the GR&R level, a new pH measuring procedure was introduced. With the new procedure, the GR&R value was able to be reduced to 2.05%, which means the tester is statistically very ideal to measure the pH of the solution prepared for WO3 hydrothermal synthesis process.

  19. [Effects of mere exposure on category evaluation measured by the IAT and the GNAT].

    PubMed

    Kawakami, Naoaki; Sato, Hirotsune; Yoshida, Fujio

    2010-12-01

    Based on mere exposure studies, we proposed that repeated exposure to stimuli belonging to a common category leads to a positive evaluation of that category. Furthermore, to investigate the implicit effects of mere exposure, indirect measures were used. In a series of experiments, participants were repeatedly exposed to mimetic words written in Japanese hiragana or katakana, or nothing (control). Then their evaluations of the category ("hiragana" or "katakana") were measured using indirect and direct measures. In Experiment 1 (Implicit Association Test; IAT), we adopted a traditional design using an exposure paradigm, such that the rating stimuli were identical to the exposed stimuli. Significant effects were observed for both measures. In Experiment 2 (IAT) and Experiment 3 (Go/No-go Association Task; GNAT), we used non-exposed stimuli that belonged to a common category as the rating stimuli. Significant effects were observed only for indirect measures. These results indicate that repeated exposure has unconscious positive effects on category evaluation. Theoretical and methodological implications of the findings are discussed.

  20. Taboo: Working memory and mental control in an interactive task

    PubMed Central

    Hansen, Whitney A.; Goldinger, Stephen D.

    2014-01-01

    Individual differences in working memory (WM) predict principled variation in tasks of reasoning, response time, memory, and other abilities. Theoretically, a central function of WM is keeping task-relevant information easily accessible while suppressing irrelevant information. The present experiment was a novel study of mental control, using performance in the game Taboo as a measure. We tested effects of WM capacity on several indices, including perseveration errors (repeating previous guesses or clues) and taboo errors (saying at least part of a taboo or target word). By most measures, high-span participants were superior to low-span participants: High-spans were better at guessing answers, better at encouraging correct guesses from teammates, and less likely to either repeat themselves or produce taboo clues. Differences in taboo errors occurred only in an easy control condition. The results suggest that WM capacity predicts behavior in tasks requiring mental control, extending this finding to an interactive group setting. PMID:19827699

  1. Measurements of propeller noise in a light turboprop airplane

    NASA Technical Reports Server (NTRS)

    Wilby, J. F.; Wilby, E. G.

    1987-01-01

    In-flight acoustic measurements have been made on the exterior and interior of a twin-engined turboprop airplane under controlled conditions to study data repeatability. It is found that the variability of the harmonic sound pressure levels in the cabin is greater than that for the exterior sound pressure levels, typical values for the standard deviation being +2.0 dB and -4.2 dB for the interior, versus +1.4 dB and -2.3 dB for the exterior. When insertion losses are determined for acoustic treatments in the cabin, the standard deviations of the data are typically + or - 6.5 dB. It is concluded that additional factors, such as accurate and repeatable selection of relative phase between propellers, controlled cabin-air-temperatures, installation of baseline acoustic absorption, and measurement of aircraft attitude, should be considered in order to reduce uncertainty in the measured data.

  2. Clinical validity of macular ganglion cell complex by spectral domain-optical coherence tomography in advanced glaucoma.

    PubMed

    Sung, Mi-Sun; Kang, Byung-Wan; Kim, Hwang-Gyun; Heo, Hwan; Park, Sang-Woo

    2014-08-01

    To evaluate the repeatability and diagnostic power of macular ganglion cell complex (mGCC) thickness and peripapillary retinal nerve fiber layer (pRNFL) thickness using a spectral domain-optical coherence tomography in advanced glaucoma. Forty advanced glaucoma patients were enrolled. Patients were divided into 2 groups of 20 patients each, according to the MD between -20 and -10 dB, and <-20 dB. The thickness of mGCC and pRNFL were measured with spectral domain-optical coherence tomography in both the groups. The repeatability of each parameter was assessed in both the groups, and the diagnostic power of each parameter was compared with the normal controls. Comparison of diagnostic power between the pRNFL and mGCC parameters revealed that the area under the receiver operating characteristic curve was not significantly different in patients with advanced glaucoma. The repeatability of pRNFL parameters was similar, irrespective of the severity of glaucoma. However, the repeatability of mGCC parameters became lower as the severity increased in patients with advanced glaucoma. In advanced glaucoma, the measurement of mGCC thickness has similar diagnostic power as the measurement of pRNFL thickness. However, the measurement of mGCC thickness showed a lower repeatability as MD decreased.

  3. Repeated Measurement of the Components of Attention with Young Children Using the Attention Network Test: Stability, Isolability, Robustness, and Reliability

    ERIC Educational Resources Information Center

    Ishigami, Yoko; Klein, Raymond M.

    2015-01-01

    The current study examined the robustness, stability, reliability, and isolability of the attention network scores (alerting, orienting, and executive control) when young children experienced repeated administrations of the child version of the Attention Network Test (ANT; Rueda et al., 2004). Ten test sessions of the ANT were administered to 12…

  4. Analysis of longitudinal "time series" data in toxicology.

    PubMed

    Cox, C; Cory-Slechta, D A

    1987-02-01

    Studies focusing on chronic toxicity or on the time course of toxicant effect often involve repeated measurements or longitudinal observations of endpoints of interest. Experimental design considerations frequently necessitate between-group comparisons of the resulting trends. Typically, procedures such as the repeated-measures analysis of variance have been used for statistical analysis, even though the required assumptions may not be satisfied in some circumstances. This paper describes an alternative analytical approach which summarizes curvilinear trends by fitting cubic orthogonal polynomials to individual profiles of effect. The resulting regression coefficients serve as quantitative descriptors which can be subjected to group significance testing. Randomization tests based on medians are proposed to provide a comparison of treatment and control groups. Examples from the behavioral toxicology literature are considered, and the results are compared to more traditional approaches, such as repeated-measures analysis of variance.

  5. Social stories: mechanisms of effectiveness in increasing game play skills in children diagnosed with autism spectrum disorder using a pretest posttest repeated measures randomized control group design.

    PubMed

    Quirmbach, Linda M; Lincoln, Alan J; Feinberg-Gizzo, Monica J; Ingersoll, Brooke R; Andrews, Siri M

    2009-02-01

    An increasing body of literature has indicated that social stories are an effective way to teach individuals diagnosed with autism appropriate social behavior. This study compared two formats of a social story targeting the improvement of social skills during game play using a pretest posttest repeated measures randomized control group design. A total of 45 children diagnosed with Autism Spectrum Disorder (ASD) ages 7-14 were randomly assigned to standard, directive, or control story conditions. Results demonstrated that the standard and directive story formats were equally as effective in eliciting, generalizing and maintaining the targeted social skills in participants who had prior game play experience and Verbal Comprehension Index (VCI) scores from the WISC-IV intelligence test in the borderline range or above.

  6. The effect of repeated diazepam administration on myocardial function in the ischemia-reperfused isolated rat heart.

    PubMed

    Shackebaei, Dareuosh; Kayhani, Bijan; Godini, Aliashraf; Pourshanazari, Aliasghar; Reshadat, Sohyla

    2009-06-01

    To evaluate whether repeated diazepam administration affects the heart in ischemia-reperfusion. This study was performed at the Medical Biology Research Center, Kermanshah, Iran, from March to September 2008. Four groups of rats were subjected to a daily injection of diazepam (group 1 [0.5 mg/kg for 21 days], group II [2.5 mg/kg for 5 days], and group III [5 mg/kg for 5 days] intraperitoneally), and saline solution (21 days) in the control groups. Isolated, perfused hearts were subjected to 40 minutes global ischemia, and 45 minutes reperfusion. The left ventricular developed pressure (LVDP), heart rate, and coronary flow were measured. Rate pressure product (RPP) was calculated. In reperfusion, released lactate dehydrogenase (LDH) enzyme in effluent was measured. It was observed that the recovery of the RPP and LVDP in reperfusion significantly decreased in the test group III (n=9) in comparison to the control (n=8). During the reperfusion period, the released LDH significantly increased in test group II (n=8) and group III in comparison with the control. The results show that repeated administration of diazepam (5 mg/kg for 5 days) reduced the cardiac performance in reperfusion, and significantly exacerbated the ischemia-reperfusion injury. It is probably mediated by the changing of cardiac susceptibility in ischemia due to repeated administration of diazepam.

  7. En face Doppler total retinal blood flow measurement with 70 kHz spectral optical coherence tomography

    PubMed Central

    Tan, Ou; Liu, Gangjun; Liang, Liu; Gao, Simon S.; Pechauer, Alex D.; Jia, Yali; Huang, David

    2015-01-01

    Abstract. An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans (2×2  mm) obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was 45.4±6.7  μl/min for healthy control and 34.7±7.6  μl/min for glaucomatous participants (p-value=0.01). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement. PMID:26062663

  8. Associations between Repeated Measures of Maternal Urinary Phthalate Metabolites and Thyroid Hormone Parameters during Pregnancy

    PubMed Central

    Johns, Lauren E.; Ferguson, Kelly K.; McElrath, Thomas F.; Mukherjee, Bhramar; Meeker, John D.

    2016-01-01

    Background: Maintaining thyroid homeostasis during pregnancy is essential for normal fetal growth and development. Growing evidence suggests that phthalates interfere with normal thyroid function. Few human studies have investigated the degree to which phthalates may affect thyroid hormone levels in particularly susceptible populations such as pregnant women. Objectives: We examined the associations between repeated measures of urinary phthalate metabolites and plasma thyroid hormone levels in samples collected at up to four time points per subject in pregnancy. Additionally, we investigated the potential windows of susceptibility to thyroid hormone disturbances related to study visit of sample collection. Methods: Data were obtained from pregnant women (n = 439) participating in a nested case–control study of preterm birth with 116 cases and 323 controls. We measured 9 phthalate metabolite concentrations in urine samples collected at up to four study visits per subject during pregnancy (median = 10, 18, 26, and 35 weeks of gestation, respectively). We also measured a panel of thyroid function markers in plasma collected at the same four time points per subject during pregnancy. Results: Although our results were generally null, in repeated measures analyses we observed that phthalate metabolites were largely inversely associated with thyrotropin and positively associated with free and total thyroid hormones. Cross-sectional analyses by study visit revealed that the magnitude and/or direction of these relationships varied by timing of exposure during gestation. Conclusions: These results support previous reports showing the potential for environmental phthalate exposure to alter circulating levels of thyroid hormones in pregnant women. Citation: Johns LE, Ferguson KK, McElrath TF, Mukherjee B, Meeker JD. 2016. Associations between repeated measures of maternal urinary phthalate metabolites and thyroid hormone parameters during pregnancy. Environ Health Perspect 124:1808–1815; http://dx.doi.org/10.1289/EHP170 PMID:27152641

  9. The effect of intervention on the free-play experience for mothers and their infants with developmental delay and cerebral palsy.

    PubMed

    Redditi Hanzlik, J

    1989-01-01

    An intervention study designed to investigate the effects of one hour of maternal and infant behavior was conducted using experimental and control groups of mothers and their infants with cerebral palsy. Ten mother-infant pairs were in each group; infants ranged in age from 8-32 months. Infants of mothers in the control group received one hour of NDT-based occupational therapy. Two-factor repeated measures analysis of variance with repeated measures of the second factor indicated that the nonverbal instruction methods were significantly more successful in modifying maternal and infant behavior than were the verbal instruction methods. Implications of the results for intervention programs and future research were discussed.

  10. Effects of the TCARE® intervention on caregiver burden and depressive symptoms: preliminary findings from a randomized controlled study.

    PubMed

    Montgomery, Rhonda J V; Kwak, Jung; Kosloski, Karl; O'Connell Valuch, Katharine

    2011-09-01

    We examined the effects of a manualized care management protocol specifically designed for care managers working with caregivers, the Tailored Caregiver Assessment and Referral® (TCARE®) protocol, on caregiver identity discrepancy, burden, and depressive symptoms. Preliminary data from a longitudinal, randomized, controlled intervention study with 266 family caregivers served by 52 care managers in 4 states were analyzed using repeated measures random effects regression procedures. Caregivers in the intervention and control groups were repeatedly assessed for up to 9 months on caregiver identity discrepancy, 3 areas of caregiving burden-objective, relationship, and stress burdens; depression; and intention for nursing home placement. We found significant group by time interaction effects for caregiver identity discrepancy, relationship burden, stress burden, depression, and intention for nursing home placement. Caregivers in the intervention group experienced significant improvement on these measures, whereas caregivers in the control group worsened on these measures over time. The preliminary findings provide strong support for effectiveness of the TCARE® protocol on improving caregiver well-being and mental health outcomes.

  11. Effects of the TCARE® Intervention on Caregiver Burden and Depressive Symptoms: Preliminary Findings From a Randomized Controlled Study

    PubMed Central

    Kwak, Jung; Kosloski, Karl; O’Connell Valuch, Katharine

    2011-01-01

    Objectives. We examined the effects of a manualized care management protocol specifically designed for care managers working with caregivers, the Tailored Caregiver Assessment and Referral® (TCARE®) protocol, on caregiver identity discrepancy, burden, and depressive symptoms. Methods. Preliminary data from a longitudinal, randomized, controlled intervention study with 266 family caregivers served by 52 care managers in 4 states were analyzed using repeated measures random effects regression procedures. Caregivers in the intervention and control groups were repeatedly assessed for up to 9 months on caregiver identity discrepancy, 3 areas of caregiving burden—objective, relationship, and stress burdens; depression; and intention for nursing home placement. Results. We found significant group by time interaction effects for caregiver identity discrepancy, relationship burden, stress burden, depression, and intention for nursing home placement. Caregivers in the intervention group experienced significant improvement on these measures, whereas caregivers in the control group worsened on these measures over time. Discussion. The preliminary findings provide strong support for effectiveness of the TCARE® protocol on improving caregiver well-being and mental health outcomes. PMID:21840840

  12. Repeatability of cold pressor test-induced flow increase assessed with H(2)(15)O and PET.

    PubMed

    Siegrist, Patrick T; Gaemperli, Oliver; Koepfli, Pascal; Schepis, Tiziano; Namdar, Mehdi; Valenta, Ines; Aiello, Floreana; Fleischmann, Samuel; Alkadhi, Hatem; Kaufmann, Philipp A

    2006-09-01

    The aim of this study was to evaluate the repeatability of endothelium-related myocardial blood flow (MBF) responses to cold pressor testing (CPT) as assessed by PET. In 10 age-matched control subjects (26.6 +/- 3.4 y) and 10 tobacco smokers (24.9 +/- 3.3 y) MBF was assessed at rest and after repeated CPT (CPT1 and CPT2, 40 min apart) using PET with H(2)(15)O. CPT was performed by a 2-min immersion of the subject's foot in ice water. MBF values were corrected for cardiac workload (rate.pressure product), and the repeatability of CPT-related MBF values was assessed according to Bland and Altman. Corrected MBF at CPT1 and CPT2 were comparable in control subjects (1.79 +/- 0.37 vs. 1.70 +/- 0.35 mL/min/g; P = not significant [NS]) and in smokers (1.97 +/- 0.42 vs. 1.80 +/- 0.41 mL/min/g; P = NS). Repeatability coefficients in control subjects and smokers were 0.46 mL/min/g (27% of the mean MBF) and 0.51 mL/min/g (27%), respectively. MBF increased significantly after CPT in both groups but tended to be lower in smokers (P = 0.08). PET measured MBF combined with CPT is a feasible and repeatable method for the evaluation of endothelium-related changes of MBF.

  13. High-resolution audiometry: an automated method for hearing threshold acquisition with quality control.

    PubMed

    Bian, Lin

    2012-01-01

    In clinical practice, hearing thresholds are measured at only five to six frequencies at octave intervals. Thus, the audiometric configuration cannot closely reflect the actual status of the auditory structures. In addition, differential diagnosis requires quantitative comparison of behavioral thresholds with physiological measures, such as otoacoustic emissions (OAEs) that are usually measured in higher resolution. The purpose of this research was to develop a method to improve the frequency resolution of the audiogram. A repeated-measure design was used in the study to evaluate the reliability of the threshold measurements. A total of 16 participants with clinically normal hearing and mild hearing loss were recruited from a population of university students. No intervention was involved in the study. Custom developed system and software were used for threshold acquisition with quality control (QC). With real-ear calibration and monitoring of test signals, the system provided accurate and individualized measure of hearing thresholds that were determined by an analysis based on signal detection theory (SDT). The reliability of the threshold measure was assessed by correlation and differences between the repeated measures. The audiometric configurations were diverse and unique to each individual ear. The accuracy, within-subject reliability, and between-test repeatability are relatively high. With QC, the high-resolution audiograms can be reliably and accurately measured. Hearing thresholds measured as ear canal sound pressures with higher frequency resolution can provide more customized hearing-aid fitting. The test system may be integrated with other physiological measures, such as OAEs, into a comprehensive evaluative tool. American Academy of Audiology.

  14. Self-reflection, gender and science achievement

    NASA Astrophysics Data System (ADS)

    Shoop, Kathleen A.

    Drawing on socio-cognitive learning theory, this study compared achievement scores of 134 male and female high school biology students randomly assigned to groups which either used self-reflection, used self-reflection and received feedback, or did not self-reflect. Following a pretest, the teacher provided self-reflection strategy instruction to students in the two intervention groups and then subsequently provided in-class self-reflection time for these groups. The posttest concluded the unit; the retention measure was five weeks later. A quasi-experimental 3 x 3 x 2 (time x intervention x gender) factorial repeated-measures control group design was used for this study; a repeated measures ANOVA and several one-way ANOVA's were used to answer the research questions. Results from the repeated-measures ANOVA revealed significant results for Time and Time x Intervention, with the reflection group demonstrating significantly lower gains from pretest to posttest than the other two groups. The ANOVA examining differences between those who reflected and those who reflected and received feedback provided significant results with similar results for the difference between the control group and the reflection group. For teachers and students this study provides several areas of practical significance. Primarily, teachers may find lower student achievement if students regularly self-reflect but do not receive feedback for their reflection.

  15. Objectively assessing treadmill walking during the second and third pregnancy trimesters.

    PubMed

    DiNallo, Jennifer M; Downs, Danielle Symons; Le Masurier, Guy

    2012-01-01

    To effectively promote physical activity (PA) and quantify the effects of PA interventions for pregnant women, PA measurement during pregnancy needs improvement. The purpose of this study was to assess PA monitor output during a controlled, treadmill walking protocol among pregnant women at 20- and 32-weeks gestation. Women (N = 43) wore an Actigraph accelerometer, NL1000, and Yamax pedometer during a 20-minute treadmill walking test [5-minute periods at 4 different speeds (54, 67, 80, and 94 m·min(-1))] at 20- and 32-weeks gestation. Repeated-measures ANOVAs indicated that Actigraph total counts/minute and minutes of moderate-vigorous PA (MVPA), NL1000 steps and minutes MVPA, and Yamax steps decreased from 20- to 32-weeks gestation (P ≤ .05), while body girth circumference and activity monitor tilt increased (P ≤ .05). Repeated measures ANCOVAs, controlling for changes in body girth and monitor tilt, yielded no significant differences in any outcome measures from 20- to 32-weeks gestation. Preliminary results suggest physical changes during pregnancy impact activity monitor output in controlled settings. Accurately measuring and statistically controlling for changes in body girth at monitor placement site and monitor tilt may improve the accuracy of activity monitors for use with pregnant populations.

  16. Automated measurement and control of concrete properties in a ready mix truck with VERIFI.

    DOT National Transportation Integrated Search

    2014-02-01

    In this research, twenty batches of concrete with six different mixture proportions were tested with VERIFI to evaluate 1) accuracy : and repeatability of VERIFI measurements, 2) ability of VERIFI to adjust slump automatically with water and admixtur...

  17. Preservice Students' Attitudes toward Pupil Control as They Develop throughout the Field Experiences.

    ERIC Educational Resources Information Center

    Killian, Joyce E.; McIntyre, D. John

    This study used repeated measures of the Pupil Control Ideology (PCI) instrument to examine the change in student teacher orientation toward pupil control ideology occurring during a three semester field experience. The instrument was given to elementary and secondary education majors at Southern Illinois University at Carbondale five different…

  18. Repeatability of a new method for measuring tear evaporation rates.

    PubMed

    Petznick, Andrea; Tan, Jen Hong; Boo, Shiao Khee; Lee, Sze Yee; Acharya, U Rajendra; Tong, Louis

    2013-04-01

    The purpose of this study was to evaluate the repeatability of tear evaporimetry based on infrared thermography in a clinical room setting and to test the effect of changing environmental humidity on ocular surface temperature (OST) and tear evaporation rates (TERs) in a controlled adverse environmental (CAE) chamber. Twenty-six healthy participants were enrolled, of whom 16 underwent repeatability measurements in a clinical room and 10 were exposed to a constant temperature of 30°C with a humidity of 45 and 65% in a CAE. Participants were acclimatized to each condition for at least 20 minutes before OSTs were taken. Tear film breakup time was assessed in the CAE only. Number of blinks and OSTs were continuously measured for 20 seconds for the cornea, conjunctiva, and overall ocular surface with an infrared camera; corresponding TERs were calculated. The OSTs and TERs showed acceptable strength of agreement between the first and second measurements. The coefficients of repeatability were 0.4°C for OST and 6.0 W m for TER. An increase in chamber humidity (from 45 to 65%) increased OST (p < 0.05). The TER was not changed significantly (p > 0.05). The tear film breakup time and number of blinks were not significantly affected by different humidity conditions. This technique has acceptable repeatability and has potential to document individual tear evaporation changes with time where humidity may differ by less than 20%.

  19. Continuous recognition of spatial and nonspatial stimuli in hippocampal-lesioned rats.

    PubMed

    Jackson-Smith, P; Kesner, R P; Chiba, A A

    1993-03-01

    The present experiments compared the performance of hippocampal-lesioned rats to control rats on a spatial continuous recognition task and an analogous nonspatial task with similar processing demands. Daily sessions for Experiment 1 involved sequential presentation of individual arms on a 12-arm radial maze. Each arm contained a Froot Loop reinforcement the first time it was presented, and latency to traverse the arm was measured. A subset of the arms were repeated, but did not contain reinforcement. Repeated arms were presented with lags ranging from 0 to 6 (0 to 6 different arm presentations occurred between the first and the repeated presentation). Difference scores were computed by subtracting the latency on first presentations from the latency on repeated presentations, and these scores were high in all rats prior to surgery, with a decreasing function across lag. There were no differences in performance following cortical control or sham surgery. However, there was a total deficit in performance following large electrolytic lesions of the hippocampus. The second experiment employed the same continuous recognition memory procedure, but used three-dimensional visual objects (toys, junk items, etc., in various shapes, sizes, and textures) as stimuli on a flat runway. As in Experiment 1, the stimuli were presented successively and latency to run to and move the object was measured. Objects were repeated with lags ranging from 0 to 4. Performance on this task following surgery did not differ from performance prior to surgery for either the control group or the hippocampal lesion group. These results provide support for Kesner's attribute model of hippocampal function in that the hippocampus is assumed to mediate data-based memory for spatial locations, but not three-dimensional visual objects.

  20. Improving power to detect changes in blood miRNA expression by accounting for sources of variability in experimental designs.

    PubMed

    Daniels, Sarah I; Sillé, Fenna C M; Goldbaum, Audrey; Yee, Brenda; Key, Ellen F; Zhang, Luoping; Smith, Martyn T; Thomas, Reuben

    2014-12-01

    Blood miRNAs are a new promising area of disease research, but variability in miRNA measurements may limit detection of true-positive findings. Here, we measured sources of miRNA variability and determine whether repeated measures can improve power to detect fold-change differences between comparison groups. Blood from healthy volunteers (N = 12) was collected at three time points. The miRNAs were extracted by a method predetermined to give the highest miRNA yield. Nine different miRNAs were quantified using different qPCR assays and analyzed using mixed models to identify sources of variability. A larger number of miRNAs from a publicly available blood miRNA microarray dataset with repeated measures were used for a bootstrapping procedure to investigate effects of repeated measures on power to detect fold changes in miRNA expression for a theoretical case-control study. Technical variability in qPCR replicates was identified as a significant source of variability (P < 0.05) for all nine miRNAs tested. Variability was larger in the TaqMan qPCR assays (SD = 0.15-0.61) versus the qScript qPCR assays (SD = 0.08-0.14). Inter- and intraindividual and extraction variability also contributed significantly for two miRNAs. The bootstrapping procedure demonstrated that repeated measures (20%-50% of N) increased detection of a 2-fold change for approximately 10% to 45% more miRNAs. Statistical power to detect small fold changes in blood miRNAs can be improved by accounting for sources of variability using repeated measures and choosing appropriate methods to minimize variability in miRNA quantification. This study demonstrates the importance of including repeated measures in experimental designs for blood miRNA research. See all the articles in this CEBP Focus section, "Biomarkers, Biospecimens, and New Technologies in Molecular Epidemiology." ©2014 American Association for Cancer Research.

  1. A study on the trinucleotide repeat associated with Huntington`s disease in the Chinese

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bing-wen Soong; Jih-tsuu Wang

    1994-09-01

    Analysis of the polymorphic (CAG)n repeat in the hungingtin gene in the chinese confirmed the presence of an expanded repeat on all Huntington`s disease chromosomes. Measurement of the specific CAG repeat sequence in 34 HD chromosomes from 15 unrelated families and 190 control chromosomes from the Chinese population showed a range from 9 to 29 repeats in normal subjects and 40 to 58 in affected subjects. The size distributions of normal and affected alleles did not overlap. A clear correlation bewteen early onset of symptoms and very high repeat number was seen, but the spread of the age-at-onset in themore » major repeat range producing characteristic HD it too wide to be of diagnostic value. There was also variability in the transmitted repeat size for both sexes in the HD size range. Maternal HD alleles showed a moderate instability with a preponderance of size decrease, while paternal HD alleles had a tendency to increase in repeat size on transmission, the degree of which appeared proportional to the initial size.« less

  2. Investigation of C9orf72 in 4 Neurodegenerative Disorders

    PubMed Central

    Xi, Zhengrui; Zinman, Lorne; Grinberg, Yakov; Moreno, Danielle; Sato, Christine; Bilbao, Juan M.; Ghani, Mahdi; Hernández, Isabel; Ruiz, Agustín; Boada, Mercè; Morón, Francisco J.; Lang, Anthony E.; Marras, Connie; Bruni, Amalia; Colao, Rosanna; Maletta, Raffaele G.; Puccio, Gianfranco; Rainero, Innocenzo; Pinessi, Lorenzo; Galimberti, Daniela; Morrison, Karen E.; Moorby, Catriona; Stockton, Joanne D.; Masellis, Mario; Black, Sandra E.; Hazrati, Lili-Naz; Liang, Yan; van Haersma de With, Jan; Fornazzari, Luis; Villagra, Roque; Rojas-Garcia, Ricardo; Clarimón, Jordi; Mayeux, Richard; Robertson, Janice; St George-Hyslop, Peter; Rogaeva, Ekaterina

    2014-01-01

    Objective To estimate the allele frequency of C9orf72 (G4C2) repeats in amyotrophic lateral sclerosis (ALS), frontotemporal lobar degeneration (FTLD), Alzheimer disease (AD), and Parkinson disease (PD). Design The number of repeats was estimated by a 2-step genotyping strategy. For expansion carriers, we sequenced the repeat flanking regions and obtained APOE genotypes and MAPT H1/H2 haplotypes. Setting Hospitals specializing in neurodegenerative disorders. Subjects We analyzed 520 patients with FTLD, 389 patients with ALS, 424 patients with AD, 289 patients with PD, 602 controls, 18 families, and 29 patients with PD with the LRRK2 G2019S mutation. Main Outcome Measure The expansion frequency. Results Based on a prior cutoff (>30 repeats), the expansion was detected in 9.3% of patients with ALS, 5.2% of patients with FTLD, and 0.7% of patients with PD but not in controls or patients with AD. It was significantly associated with family history of ALS or FTLD and age at onset of FTLD. Phenotype variation (ALS vs FTLD) was not associated with MAPT, APOE, or variability in the repeat flanking regions. Two patients with PD were carriers of 39 and 32 repeats with questionable pathological significance, since the 39-repeat allele does not segregate with PD. No expansion or intermediate alleles (20–29 repeats) were found among the G2019S carriers and AD cases with TAR DNA-binding protein 43–positive inclusions. Surprisingly, the frequency of the 10-repeat allele was marginally increased in all 4 neurodegenerative diseases compared with controls, indicating the presence of an unknown risk variation in the C9orf72 locus. Conclusions The C9orf72 expansion is a common cause of ALS and FTLD, but not of AD or PD. Our study raises concern about a reliable cutoff for the pathological repeat number, which is important in the utility of genetic screening. PMID:22964832

  3. Broadband geophysical time series data from a stressed environment

    NASA Astrophysics Data System (ADS)

    Pun, W.; Saleh, R.; Zwaan, D.; Milkereit, B.; Valley, B.; Pilz, M.; Milkereit, C.; Milkereit, R.

    2011-12-01

    As classical exploration geophysical tools and techniques find new application in time lapse and monitoring studies, a fresh look at the performance and repeatability of various geophysical techniques is worth to take a closer look. We used an active, deep mine site close to Sudbury (Canada) for 3D deployment of broadband geophysical sensors for passive monitoring and detecting anomalous regions in the earth based on physical rock properties. In addition, we conducted controlled source experiments to evaluate repeatability of geophysical sources. To extend from detection to monitoring, continuous repeated measurements are necessary over a long period of time. If a controlled source is stable, the convolution problem is simplified such that any variation in the geophysical data is an effect of the earth's response. Repeated measurements are important for in-mine use to provide a better insight of stress and strain changes due to natural events and mining processes. The development, build-up and redistribution of stress lead to rock failures that can have disastrous consequences if they occur in an uncontrolled manner. In this project, different continuous and repeated in-situ geophysical measurements from a deep underground mine were analyzed to validate the feasibility of in-mine monitoring. Data acquisition tests covered both active and passive methods: gravity meter, fibre optic strain meters, fixed and portable three-component seismic arrays, EM induction coils and borehole based DC/IP resistivity sensors. The newly acquired data cover a wide range of frequencies which allow the study of short- and long-period events, ranging from 10-5 Hz to 10 kHz. Earth tides, global seismic events, tremors, acoustic emissions (microseismic events) and blasts were recorded within a 3D volume.

  4. An L-band SAR for repeat pass deformation measurements on a UAV platform

    NASA Technical Reports Server (NTRS)

    Hensley, Scott; Lou, Yunling; Rosen, Paul; Wheeler, Kevin; Zebker, Howard; Madsen, Soren; Miller, Tim; Hoffman, Jim; Farra, Don

    2003-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeat-pass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV) or minimally piloted vehicle (MPV). Upon surveying the capabilities and availabilities of such aircraft, the Proteus aircraft and the ALTAIR UAV appear to meet our criteria in terms of payload capabilities, flying altitude, and endurance. To support the repeat pass deformation capability it is necessary to control flight track capability of the aircraft to be within a specified 10 m tube with a goal of 1 m. This requires real-time GPS control of the autopilot to achieve these objectives that has not been demonstrated on these aircraft. Based on the Proteus and ALTAIR's altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and a 16 km range swath. The radar will have an active electronic beam steering antenna to achieve a Doppler centroid stability that is necessary for repeat-pass interferometry. This paper presents some of the trade studies for the platform, instrument and the expected science.

  5. Acute effects of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion.

    PubMed

    Kobayashi, Ryota; Hashimoto, Yuto; Hatakeyama, Hiroyuki; Okamoto, Takanobu

    2018-03-22

    The aim of this study was to investigate the acute repeated bouts of aerobic exercise decrease leg arterial stiffness. However, the influence of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion is unknown. The present study investigates the acute effects of repeated bouts of aerobic exercise on arterial stiffness after the 75-g oral glucose tolerance test (OGTT). Ten healthy young men (age, 23.2 ± 0.9 years) performed repeated bouts of aerobic exercise trial (RE, 65% peak oxygen uptake; two 15 min bouts of cycling performed 20 min apart) and control trial (CON, seated and resting in a quiet room) at 80 min before the 75-g OGTT on separate days in a randomized, controlled crossover fashion. Carotid-femoral (aortic) and femoral-ankle (leg) pulse wave velocity, carotid augmentation index, brachial and ankle blood pressure, heart rate and blood glucose and insulin levels were measured before (baseline) and 30, 60 and 120 min after the 75-g OGTT. Leg pulse wave velocity, ankle systolic blood pressure and blood glucose levels increased from baseline after the 75-g OGTT in the CON trial, but not in the RE trial. The present findings indicate that acute repeated bouts of aerobic exercise before glucose ingestion suppress increases in leg arterial stiffness following glucose ingestion. RE trial repeated bouts of aerobic exercise trial; CON trial control trial; BG blood glucose; VO 2peak peak oxygen uptake; PWV Pulse wave velocity; AIx carotid augmentation index; BP blood pressure; HR heart rate; CVs coefficients of variation; RPE Ratings of perceived exertion; SE standard error.

  6. Repeated testing improves achievement in a blended learning approach for risk competence training of medical students: results of a randomized controlled trial.

    PubMed

    Spreckelsen, C; Juenger, J

    2017-09-26

    Adequate estimation and communication of risks is a critical competence of physicians. Due to an evident lack of these competences, effective training addressing risk competence during medical education is needed. Test-enhanced learning has been shown to produce marked effects on achievements. This study aimed to investigate the effect of repeated tests implemented on top of a blended learning program for risk competence. We introduced a blended-learning curriculum for risk estimation and risk communication based on a set of operationalized learning objectives, which was integrated into a mandatory course "Evidence-based Medicine" for third-year students. A randomized controlled trial addressed the effect of repeated testing on achievement as measured by the students' pre- and post-training score (nine multiple-choice items). Basic numeracy and statistical literacy were assessed at baseline. Analysis relied on descriptive statistics (histograms, box plots, scatter plots, and summary of descriptive measures), bootstrapped confidence intervals, analysis of covariance (ANCOVA), and effect sizes (Cohen's d, r) based on adjusted means and standard deviations. All of the 114 students enrolled in the course consented to take part in the study and were assigned to either the intervention or control group (both: n = 57) by balanced randomization. Five participants dropped out due to non-compliance (control: 4, intervention: 1). Both groups profited considerably from the program in general (Cohen's d for overall pre vs. post scores: 2.61). Repeated testing yielded an additional positive effect: while the covariate (baseline score) exhibits no relation to the post-intervention score, F(1, 106) = 2.88, p > .05, there was a significant effect of the intervention (repeated tests scenario) on learning achievement, F(1106) = 12.72, p < .05, d = .94, r = .42 (95% CI: [.26, .57]). However, in the subgroup of participants with a high initial numeracy score no similar effect could be observed. Dedicated training can improve relevant components of risk competence of medical students. An already promising overall effect of the blended learning approach can be improved significantly by implementing a test-enhanced learning design, namely repeated testing. As students with a high initial numeracy score did not profit equally from repeated testing, target-group specific opt-out may be offered.

  7. The flight test of Pi-SAR(L) for the repeat-pass interferometric SAR

    NASA Astrophysics Data System (ADS)

    Nohmi, Hitoshi; Shimada, Masanobu; Miyawaki, Masanori

    2006-09-01

    This paper describes the experiment of the repeat pass interferometric SAR using Pi-SAR(L). The air-borne repeat-pass interferometric SAR is expected as an effective method to detect landslide or predict a volcano eruption. To obtain a high-quality interferometric image, it is necessary to make two flights on the same flight pass. In addition, since the antenna of the Pi-SAR(L) is secured to the aircraft, it is necessary to fly at the same drift angle to keep the observation direction same. We built a flight control system using an auto pilot which has been installed in the airplane. This navigation system measures position and altitude precisely with using a differential GPS, and the PC Navigator outputs a difference from the desired course to the auto pilot. Since the air density is thinner and the speed is higher than the landing situation, the gain of the control system is required to be adjusted during the repeat pass flight. The observation direction could be controlled to some extent by adjusting a drift angle with using a flight speed control. The repeat-pass flight was conducted in Japan for three days in late November. The flight was stable and the deviation was within a few meters for both horizontal and vertical direction even in the gusty condition. The SAR data were processed in time domain based on range Doppler algorism to make the complete motion compensation. Thus, the interferometric image processed after precise phase compensation is shown.

  8. UAV-based L-band SAR with precision flight path control

    NASA Astrophysics Data System (ADS)

    Madsen, Soren N.; Hensley, Scott; Wheeler, Kevin; Sadowy, Gregory A.; Miller, Tim; Muellerschoen, Ron; Lou, Yunling; Rosen, Paul A.

    2005-01-01

    NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also know as differential interferometric measurements. Differential interferometry can provide key displacement measurements, important for the scientific studies of Earthquakes and volcanoes1. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The radar will be designed to operate on a UAV (Unmanned Arial Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus build by Scaled Composites. The application requires control of the flight path to within a 10 m tube to support repeat track and formation flying measurements. The design is fully polarimetric with an 80 MHz bandwidth (2 m range resolution) and 16 km range swath. The antenna is an electronically steered array to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. The system will nominally operate at 45,000 ft. The program started out as a Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

  9. UAV-Based L-Band SAR with Precision Flight Path Control

    NASA Technical Reports Server (NTRS)

    Madsen, Soren N.; Hensley, Scott; Wheeler, Kevin; Sadowy, Greg; Miller, Tim; Muellerschoen, Ron; Lou, Yunling; Rosen, Paul

    2004-01-01

    NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also know as differential interferometric measurements. Differential interferometry can provide key displacement measurements, important for the scientific studies of Earthquakes and volcanoes. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The radar will be designed to operate on a UAV (Unmanned Arial Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus build by Scaled Composites. The application requires control of the flight path to within a 10 meter tube to support repeat track and formation flying measurements. The design is fully polarimetric with an 80 MHz bandwidth (2 meter range resolution) and 16 kilometer range swath. The antenna is an electronically steered array to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. The system will nominally operate at 45,000 ft. The program started out as a Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

  10. Analyzing Randomized Controlled Interventions: Three Notes for Applied Linguists

    ERIC Educational Resources Information Center

    Vanhove, Jan

    2015-01-01

    I discuss three common practices that obfuscate or invalidate the statistical analysis of randomized controlled interventions in applied linguistics. These are (a) checking whether randomization produced groups that are balanced on a number of possibly relevant covariates, (b) using repeated measures ANOVA to analyze pretest-posttest designs, and…

  11. An Evaluation of Nutrition Education Program for Low-Income Youth

    ERIC Educational Resources Information Center

    Kemirembe, Olive M. K.; Radhakrishna, Rama B.; Gurgevich, Elise; Yoder, Edgar P.; Ingram, Patreese D.

    2011-01-01

    A quasi-experimental design consisting of pretest, posttest, and delayed posttest comparison control group was used. Nutrition knowledge and behaviors were measured at pretest (time 1) posttest (time 2) and delayed posttest (time 3). General Linear Model (GLM) repeated measure ANCOVA results showed that youth who received nutrition education…

  12. The application of robotics to microlaryngeal laser surgery.

    PubMed

    Buckmire, Robert A; Wong, Yu-Tung; Deal, Allison M

    2015-06-01

    To evaluate the performance of human subjects, using a prototype robotic micromanipulator controller in a simulated, microlaryngeal operative setting. Observational cross-sectional study. Twenty-two human subjects with varying degrees of laser experience performed CO2 laser surgical tasks within a simulated microlaryngeal operative setting using an industry standard manual micromanipulator (MMM) and a prototype robotic micromanipulator controller (RMC). Accuracy, repeatability, and ablation consistency measures were obtained for each human subject across both conditions and for the preprogrammed RMC device. Using the standard MMM, surgeons with >10 previous laser cases performed superior to subjects with fewer cases on measures of error percentage and cumulative error (P = .045 and .03, respectively). No significant differences in performance were observed between subjects using the RMC device. In the programmed (P/A) mode, the RMC performed equivalently or superiorly to experienced human subjects on accuracy and repeatability measures, and nearly an order of magnitude better on measures of ablation consistency. The programmed RMC performed significantly better for repetition error when compared to human subjects with <100 previous laser cases (P = .04). Experienced laser surgeons perform better than novice surgeons on tasks of accuracy and repeatability using the MMM device but roughly equivalently using the novel RMC. Operated in the P/A mode, the RMC performs equivalently or superior to experienced laser surgeons using the industry standard MMM for all measured parameters, and delivers an ablation consistency nearly an order of magnitude better than human laser operators. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Psychophysiological correlates of relaxation induced by standard autogenic training.

    PubMed

    Mishima, N; Kubota, S; Nagata, S

    1999-01-01

    The present study aimed to determine the psychophysiological changes induced in subjects by standard autogenic training (AT). Physiological measurements were taken under strict experimental conditions. Thirty-one healthy students were divided randomly into two groups: the AT group and the control group. In the first session, the physiological variables were measured for all students before and after all were asked to relax in their own way. The AT group were then taught AT for 3 months, after which time the measurements were repeated. In the second session, the AT group practised the standard AT exercise, while the control group repeated their own form of simple relaxation. Electrocardiogram, plethysmogram (PTG) and blood pressure (BP) were measured while the students carried out a breathing rate of 15 cycles/min. The R-R intervals and BP were analysed by an autoregressive model for spectral analysis, and the data were compared by repeated-measures ANOVA. The AT group had a significant increase in the mean R-R interval and a significant decrease in the baseline deflection of the PTG in the second session. There were no significant changes in sympathetic activity except for the change in the PTG, although low frequency amplitude of systolic BP decreased slightly. AT was found to induce significant changes that were independent of respiration in healthy students, although paced breathing might have operated as a mental stress. The increase in mean R-R interval and the decrease in baseline deflection of the PTG were the most robust correlates of AT.

  14. Repeatability of circadian behavioural variation revealed in free-ranging marine fish.

    PubMed

    Alós, Josep; Martorell-Barceló, Martina; Campos-Candela, Andrea

    2017-02-01

    Repeatable between-individual differences in the behavioural manifestation of underlying circadian rhythms determine chronotypes in humans and terrestrial animals. Here, we have repeatedly measured three circadian behaviours, awakening time, rest onset and rest duration, in the free-ranging pearly razorfish, Xyrithchys novacula , facilitated by acoustic tracking technology and hidden Markov models. In addition, daily travelled distance, a standard measure of daily activity as fish personality trait, was repeatedly assessed using a State-Space Model. We have decomposed the variance of these four behavioural traits using linear mixed models and estimated repeatability scores ( R ) while controlling for environmental co-variates: year of experimentation, spatial location of the activity, fish size and gender and their interactions. Between- and within-individual variance decomposition revealed significant R s in all traits suggesting high predictability of individual circadian behavioural variation and the existence of chronotypes. The decomposition of the correlations among chronotypes and the personality trait studied here into between- and within-individual correlations did not reveal any significant correlation at between-individual level. We therefore propose circadian behavioural variation as an independent axis of the fish personality, and the study of chronotypes and their consequences as a novel dimension in understanding within-species fish behavioural diversity.

  15. Analysis of the repeatability of the exhaust pollutants emission research results for cold and hot starts under controlled driving cycle conditions.

    PubMed

    Jaworski, Artur; Kuszewski, Hubert; Ustrzycki, Adam; Balawender, Krzysztof; Lejda, Kazimierz; Woś, Paweł

    2018-04-20

    Measurement of car engines exhaust pollutants emissions is very important because of their harmful effects on the environment. This article presents the assessment of repeatability of the passenger car engine exhaust pollutants emission research results obtained in the conditions of a chassis dynamometer. The research was conducted in a climate chamber, enabling the temperature conditions to be determined from - 20 to + 30 °C. The emission of CO, CH 4 , CO 2 , NO X , THC, and NMHC was subjected to the analysis. The aim of the research is to draw attention to the accuracy of the pollutant emission research results in driving cycles, and the comparison of pollutant emission results and their repeatability obtained in successive NEDC cycles under cold and hot start conditions. The results of the analysis show that, in the case of a small number of measurements, the results repeatability analysis is necessary for a proper interpretation of the pollutant emission results on the basis of the mean value. According to the authors' judgment, it is beneficial to determine the coefficient of variation for a more complete assessment of exhaust emission result repeatability obtained from a small number of measurements. This parameter is rarely presented by the authors of papers on exhaust components emission research.

  16. Validating a new device for measuring tear evaporation rates.

    PubMed

    Rohit, Athira; Ehrmann, Klaus; Naduvilath, Thomas; Willcox, Mark; Stapleton, Fiona

    2014-01-01

    To calibrate and validate a commercially available dermatology instrument to measure tear evaporation rate of contact lens wearers. A dermatology instrument was modified by attaching a swim goggle cup such that the cup sealed around the eye socket. Results for the unmodified instrument are dependent on probe area and enclosed volume. Calibration curves were established using a model eye, to account for individual variations in chamber volume and exposed area. Fifteen participants were recruited and the study included a contact lens wear and a no contact lens wear stage. Day and diurnal variation of the measurements were assessed by taking the measurement three times a day over 2 days. The coefficient of repeatability of the measurement was calculated and a linear mixed model assessed the influence of humidity, temperature, contact lens wear, day and diurnal variations on tear evaporation rate. The associations between variables were assessed using Pearson correlation coefficient. Absolute evaporation rates with and without contact lens wear were calculated based on the new calibration. The measurements were most repeatable during the evening with no lens wear (COR = 49 g m⁻² h) and least repeatable during the evening with contact lens wear (COR = 93 g m⁻² h). Humidity (p = 0.007), and contact lens wear (p < 0.01), significantly affected the tear evaporation rate. However, temperature (p = 0.54) diurnal variation (p = 0.85) and different days (p = 0.65) had no significant effect after controlling for humidity. Tear evaporation rates can be measured using a modified dermatology instrument. Measurements were higher and more variable with lens wear consistent with previous literature. Control of environmental conditions is important as a higher humidity results in a reduced evaporation rate. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  17. Consistency evaluation of values of weight, height, and body mass index in Food Intake and Physical Activity of School Children: the quality control of data entry in the computerized system.

    PubMed

    Jesus, Gilmar Mercês de; Assis, Maria Alice Altenburg de; Kupek, Emil; Dias, Lizziane Andrade

    2017-01-01

    The quality control of data entry in computerized questionnaires is an important step in the validation of new instruments. The study assessed the consistency of recorded weight and height on the Food Intake and Physical Activity of School Children (Web-CAAFE) between repeated measures and against directly measured data. Students from the 2nd to the 5th grade (n = 390) had their weight and height directly measured and then filled out the Web-CAAFE. A subsample (n = 92) filled out the Web-CAAFE twice, three hours apart. The analysis included hierarchical linear regression, mixed linear regression model, to evaluate the bias, and intraclass correlation coefficient (ICC), to assess consistency. Univariate linear regression assessed the effect of gender, reading/writing performance, and computer/internet use and possession on residuals of fixed and random effects. The Web-CAAFE showed high values of ICC between repeated measures (body weight = 0.996, height = 0.937, body mass index - BMI = 0.972), and regarding the checked measures (body weight = 0.962, height = 0.882, BMI = 0.828). The difference between means of body weight, height, and BMI directly measured and recorded was 208 g, -2 mm, and 0.238 kg/m², respectively, indicating slight BMI underestimation due to underestimation of weight and overestimation of height. This trend was related to body weight and age. Height and weight data entered in the Web-CAAFE by children were highly correlated with direct measurements and with the repeated entry. The bias found was similar to validation studies of self-reported weight and height in comparison to direct measurements.

  18. Repeated immobilization stress alters rat hippocampal and prefrontal cortical morphology in parallel with endogenous agmatine and arginine decarboxylase levels

    PubMed Central

    Zhu, Meng-Yang; Wang, Wei-Ping; Huang, Jingjing; Feng, Yang-Zheng; Regunathan, Soundar; Bissette, Garth

    2008-01-01

    Agmatine, an endogenous amine derived from decarboxylation of L-arginine catalyzed by arginine decarboxylase, has been proposed as a neurotransmitter or neuromodulator in the brain. In the present study we examined whether agmatine has neuroprotective effects against repeated immobilization-induced morphological changes in brain tissues and possible effects of immobilization stress on endogenous agmatine levels and arginine decarboxylase expression in rat brains. Sprague-Dawley rats were subjected to two hour immobilization stress daily for seven days. This paradigm significantly increased plasma corticosterone levels, and the glutamate efflux in the hippocampus as measured by in vivo microdialysis. Immunohistochemical staining with β-tubulin III showed that repeated immobilization caused marked morphological alterations in the hippocampus and medial prefrontal cortex that were prevented by simultaneous treatment with agmatine (50 mg/kg/day, i.p.). Likewise, endogenous agmatine levels measured by high performance liquid chromatography in the prefrontal cortex, hippocampus, striatum and hypothalamus were significantly increased by immobilization, as compared to controls. The increased endogenous agmatine levels, ranging from 92% to 265% of controls, were accompanied by a significant increase of arginine decarboxylase protein levels in the same regions. These results demonstrate that administration of exogenous agmatine protects the hippocampus and medial prefrontal cortex against neuronal insults caused by repeated immobilization. The parallel increase in endogenous brain agmatine and arginine decarboxylase protein levels triggered by repeated immobilization indicates that the endogenous agmatine system may play an important role in adaptation to stress as a potential neuronal self-protection mechanism. PMID:18832001

  19. Experimental creation of quantum Zeno subspaces by repeated multi-spin projections in diamond

    NASA Astrophysics Data System (ADS)

    Kalb, N.; Cramer, J.; Twitchen, D. J.; Markham, M.; Hanson, R.; Taminiau, T. H.

    2016-10-01

    Repeated observations inhibit the coherent evolution of quantum states through the quantum Zeno effect. In multi-qubit systems this effect provides opportunities to control complex quantum states. Here, we experimentally demonstrate that repeatedly projecting joint observables of multiple spins creates quantum Zeno subspaces and simultaneously suppresses the dephasing caused by a quasi-static environment. We encode up to two logical qubits in these subspaces and show that the enhancement of the dephasing time with increasing number of projections follows a scaling law that is independent of the number of spins involved. These results provide experimental insight into the interplay between frequent multi-spin measurements and slowly varying noise and pave the way for tailoring the dynamics of multi-qubit systems through repeated projections.

  20. Thermotactile perception thresholds measurement conditions.

    PubMed

    Maeda, Setsuo; Sakakibara, Hisataka

    2002-10-01

    The purpose of this paper is to investigate the effects of posture, push force and rate of temperature change on thermotactile thresholds and to clarify suitable measuring conditions for Japanese people. Thermotactile (warm and cold) thresholds on the right middle finger were measured with an HVLab thermal aesthesiometer. Subjects were eight healthy male Japanese students. The effects of posture in measurement were examined in the posture of a straight hand and forearm placed on a support, the same posture without a support, and the fingers and hand flexed at the wrist with the elbow placed on a desk. The finger push force applied to the applicator of the thermal aesthesiometer was controlled at a 0.5, 1.0, 2.0 and 3.0 N. The applicator temperature was changed to 0.5, 1.0, 1.5, 2.0 and 2.5 degrees C/s. After each measurement, subjects were asked about comfort under the measuring conditions. Three series of experiments were conducted on different days to evaluate repeatability. Repeated measures ANOVA showed that warm thresholds were affected by the push force and the rate of temperature change and that cold thresholds were influenced by posture and push force. The comfort assessment indicated that the measurement posture of a straight hand and forearm laid on a support was the most comfortable for the subjects. Relatively high repeatability was obtained under measurement conditions of a 1 degrees C/s temperature change rate and a 0.5 N push force. Measurement posture, push force and rate of temperature change can affect the thermal threshold. Judging from the repeatability, a push force of 0.5 N and a temperature change of 1.0 degrees C/s in the posture with the straight hand and forearm laid on a support are recommended for warm and cold threshold measurements.

  1. 40 CFR 1066.20 - Units of measure and overview of calculations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Applicability and General Provisions § 1066.20 Units of..., repeatability, linearity, or noise specification. See 40 CFR 1065.1001 for the definition of tolerance. In this...

  2. [Analysis of variance of repeated data measured by water maze with SPSS].

    PubMed

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (P

  3. Influencing Antecedents of Adolescent Risk-Taking Behaviour in Elementary School: Results of a 4-Year Quasi-Experimental Controlled Trial

    ERIC Educational Resources Information Center

    Maruska, K.; Morgenstern, M.; Isensee, B.; Hanewinkel, R.

    2010-01-01

    Effects of the life skills programme "Eigenstandig werden" (Becoming independent) on life skills and on identified antecedents of adolescent health risk behaviour, childhood internalizing and externalizing behaviour were tested in an elementary school setting. A quasi-experimental controlled trial with five repeated measures was…

  4. Influences of Sentence Length and Syntactic Complexity on the Speech Motor Control of Children Who Stutter

    ERIC Educational Resources Information Center

    MacPherson, Megan K.; Smith, Anne

    2013-01-01

    Purpose: To investigate the potential effects of increased sentence length and syntactic complexity on the speech motor control of children who stutter (CWS). Method: Participants repeated sentences of varied length and syntactic complexity. Kinematic measures of articulatory coordination variability and movement duration during perceptually…

  5. Barrier function and natural moisturizing factor levels after cumulative exposure to a fruit-derived organic acid and a detergent: different outcomes in atopic and healthy skin and relevance for occupational contact dermatitis in the food industry.

    PubMed

    Angelova-Fischer, Irena; Hoek, Anne-Karin; Dapic, Irena; Jakasa, Ivone; Kezic, Sanja; Fischer, Tobias W; Zillikens, Detlef

    2015-12-01

    Fruit-derived organic compounds and detergents are relevant exposure factors for occupational contact dermatitis in the food industry. Although individuals with atopic dermatitis (AD) are at risk for development of occupational contact dermatitis, there have been no controlled studies on the effects of repeated exposure to multiple irritants, relevant for the food industry, in atopic skin. The aim of the study was to investigate the outcomes of repeated exposure to a fruit-derived organic acid and a detergent in AD compared to healthy volunteers. The volunteers were exposed to 2.0% acetic acid (AcA) and/or 0.5% sodium lauryl sulfate (SLS) in controlled tandem repeated irritation test. The outcomes were assessed by measurements of erythema, transepidermal water loss (TEWL) and natural moisturizing factor (NMF) levels. In the AD volunteers, repeated AcA exposure led to barrier disruption and significant TEWL increase; no significant differences after the same exposure in the healthy controls were found. Repeated exposure to SLS and the irritant tandems enhanced the reactions and resulted in a significantly higher increase in TEWL in the AD compared to the control group. Cumulative irritant exposure reduced the NMF levels in both groups. Differences in the severity of irritant-induced barrier impairment in atopic individuals contribute to the risk for occupational contact dermatitis in result of multiple exposures to food-derived irritants and detergents. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Accuracy of force and center of pressure measures of the Wii Balance Board.

    PubMed

    Bartlett, Harrison L; Ting, Lena H; Bingham, Jeffrey T

    2014-01-01

    The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within ± 9.1N, and of COP location within ± 4.1mm. However, repeatability of a single measurement within a board was better (4.5 N, 1.5mm), suggesting that the WBB is best used for relative measures using the same device, rather than absolute measurement across devices. Internally stored calibration values were comparable to those determined experimentally. Further, heavy wear did not significantly degrade performance. In combination with prior evaluation of WBB performance and published standards for measuring human balance, our study provides necessary information to evaluate the use of the WBB for analysis of human balance control. We suggest the WBB may be useful for low-resolution measurements, but should not be considered as a replacement for laboratory-grade force plates. Published by Elsevier B.V.

  7. Accuracy of force and center of pressure measures of the Wii Balance Board

    PubMed Central

    Bartlett, Harrison L.; Ting, Lena H.; Bingham, Jeffrey T.

    2013-01-01

    The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within ±9.1 N, and of COP location within ±4.1 mm. However, repeatability of a single measurement within a board was better (4.5 N, 1.5 mm), suggesting that the WBB is best used for relative measures using the same device, rather than absolute measurement across devices. Internally stored calibration values were comparable to those determined experimentally. Further, heavy wear did not significantly degrade performance. In combination with prior evaluation of WBB performance and published standards for measuring human balance, our study provides necessary information to evaluate the use of the WBB for analysis of human balance control. We suggest the WBB may be useful for low-resolution measurements, but should not be considered as a replacement for laboratory-grade force plates. PMID:23910725

  8. Repeated allergen exposure enhances excitatory nonadrenergic noncholinergic nerve-mediated bronchoconstriction in sensitized guinea-pigs.

    PubMed

    Kageyama, N; Ichinose, M; Igarashi, A; Miura, M; Yamauchi, H; Sasaki, Y; Ishikawa, J; Tomaki, M; Shirato, K

    1996-07-01

    The effect of repeated allergen inhalation challenge on the airway excitatory nonadrenergic noncholinergic (e-NANC) nerve-mediated bronchoconstrictor response was studied in ovalbumin (OA) sensitized guinea-pigs. Three weeks after sensitization, OA inhalation, 0.03% for 3 min (challenged group), or saline inhalation (control group) was repeated every day for 4 weeks. The e-NANC nerve function was examined in vitro by means of isometric tension measurement of main bronchi. After pretreatment with atropine (10(-6) M) and propranolol (10(-6) M), we performed electrical field stimulation (EFS) or exogenous neurokinin A (NKA) administration. In the challenged group, EFS-induced main bronchial contraction was significantly greater than that of the control group (p < 0.05 or p < 0.01), but exogenous NKA-mediated responses were almost the same in both groups. The e-NANC-induced main bronchial contractions after EFS were enhanced by pretreatment with the neutral endopeptidase inhibitor, phosphoramidon, to the same degree in the control and challenged groups, indicating that the peptide degradation mechanisms were not impaired even in the challenged group. Substance P immunoreactivities in the lung of the challenged group were significantly higher than those of the control group. These results suggest that chronic airway inflammation after repeated allergen challenge increases excitatory nonadrenergic noncholinergic nerve function, possibly by enhancing sensory neuropeptide production and/or release.

  9. The Enigma of Rapid Repeat Pregnancy: A Qualitative Study of Teen Mothers.

    PubMed

    Conroy, K N; Engelhart, T G; Martins, Y; Huntington, N L; Snyder, A F; Coletti, K D; Cox, J E

    2016-06-01

    Rapid repeat pregnancy accounts for 18% of teen pregnancies and leads to adverse health, economic, and developmental outcomes for teen mothers and their children. Few interventions have been successful in reducing rapid repeat pregnancy. In this qualitative study we examined adolescent mothers' perceptions of their decision-making and behaviors that helped prevent or promote a rapid repeat pregnancy. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: Semistructured interviews were conducted with 31 adolescent mothers, aged 16-21 years; 15 of these subjects experienced a repeat pregnancy within a year of their first child's birth and 16 had not. Two researchers used a grounded, inductive technique to identify emergent themes; interviews were subsequently coded accordingly. Counts were tabulated of the number of times themes were endorsed among those with or without a repeat pregnancy. Four overarching themes emerged from the interviews: intentionality regarding pregnancy planning, patients' degree of independence in making contraceptive choices, sense of control over life experience, and barriers to follow-through on contraceptive planning. Teens who had not experienced a rapid repeat pregnancy more often endorsed themes of intentionality in preventing or promoting a pregnancy, independence in decision-making, and feelings of control over their experience. Ambivalence and lack of decision-making about seeking another pregnancy were frequently endorsed by mothers who had experienced a second pregnancy. Decision-making regarding seeking or preventing a rapid repeat pregnancy is complex for teen mothers; techniques to help support decision-making or to delay pregnancy until decision-repeat making is complete might be important in reducing rapid pregnancy. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  10. The Effects of Oral and Silent Reading on Reading Comprehension

    ERIC Educational Resources Information Center

    Schimmel, Naomi; Ness, Molly

    2017-01-01

    This study examined the effects of reading mode (oral and silent) and text genre (narrative and expository) on fourth graders' reading comprehension. While controlling for prior reading ability of 48 participants, we measured comprehension. Using a repeated measured design, data were analyzed using analysis of covariance, paired t-tests, and…

  11. Repeat sample intraocular pressure variance in induced and naturally ocular hypertensive monkeys.

    PubMed

    Dawson, William W; Dawson, Judyth C; Hope, George M; Brooks, Dennis E; Percicot, Christine L

    2005-12-01

    To compare repeat-sample means variance of laser induced ocular hypertension (OH) in rhesus monkeys with the repeat-sample mean variance of natural OH in age-range matched monkeys of similar and dissimilar pedigrees. Multiple monocular, retrospective, intraocular pressure (IOP) measures were recorded repeatedly during a short sampling interval (SSI, 1-5 months) and a long sampling interval (LSI, 6-36 months). There were 5-13 eyes in each SSI and LSI subgroup. Each interval contained subgroups from the Florida with natural hypertension (NHT), induced hypertension (IHT1) Florida monkeys, unrelated (Strasbourg, France) induced hypertensives (IHT2), and Florida age-range matched controls (C). Repeat-sample individual variance means and related IOPs were analyzed by a parametric analysis of variance (ANOV) and results compared to non-parametric Kruskal-Wallis ANOV. As designed, all group intraocular pressure distributions were significantly different (P < or = 0.009) except for the two (Florida/Strasbourg) induced OH groups. A parametric 2 x 4 design ANOV for mean variance showed large significant effects due to treatment group and sampling interval. Similar results were produced by the nonparametric ANOV. Induced OH sample variance (LSI) was 43x the natural OH sample variance-mean. The same relationship for the SSI was 12x. Laser induced ocular hypertension in rhesus monkeys produces large IOP repeat-sample variance mean results compared to controls and natural OH.

  12. Stimulus-level interference disrupts repetition benefit during task switching in middle childhood

    PubMed Central

    Karayanidis, Frini; Jamadar, Sharna; Sanday, Dearne

    2013-01-01

    The task-switching paradigm provides a powerful tool to measure the development of core cognitive control processes. In this study, we use the alternating runs task-switching paradigm to assess preparatory control processes involved in flexibly preparing for a predictable change in task and stimulus-driven control processes involved in controlling stimulus-level interference. We present three experiments that examine behavioral and event-related potential (ERP) measures of task-switching performance in middle childhood and young adulthood under low and high stimulus interference conditions. Experiment 1 confirms that our new child-friendly tasks produce similar behavioral and electrophysiological findings in young adults as those previously reported. Experiment 2 examines task switching with univalent stimuli across a range of preparation intervals in middle childhood. Experiment 3 compares task switching with bivalent stimuli across the same preparation intervals in children and young adults. Children produced a larger RT switch cost than adults with univalent stimuli and a short preparation interval. Both children and adults showed significant reduction in switch cost with increasing preparation interval, but in children this was caused by greater increase in RT for repeat than switch trials. Response-locked ERPs showed intact preparation for univalent, but less efficient preparation for bivalent stimulus conditions. Stimulus-locked ERPs confirmed that children showed greater stimulus-level interference for repeat trials, especially with bivalent stimuli. We conclude that children show greater stimulus-level interference especially for repeat trials under high interference conditions, suggesting weaker mental representation of the current task set. PMID:24367317

  13. Macular pigment and lens optical density measurements-evaluating a flicker machine with novel features

    NASA Astrophysics Data System (ADS)

    Mukherjee, Anirbaan

    Age related macular degeneration (AMD) is one of the leading causes of blindness amongst the elderly. Macular pigment (MP) in the retina has been established to protect individuals against AMD. Improving levels of MP by diet or supplements is the constant quest of clinical practitioners and researchers, thus necessitating development of instruments capable of repeatable and reliable MP measurement. Cataract, a consequence of the rising opacity levels of the lens with age is one of the other major causes of blindness in the world. Mapcatsf, a LED-based microprocessor-controlled heterochromatic flicker photometer (HFP) using photopic vision is capable of measuring the levels of MP and the opacity of the lens in terms of optical density. Test-retest measurements conducted on 83 subjects were analyzed for repeatability in macular pigment optical density (MPOD) measurements. Reliability of the lens optical density (LOD) measurements were tested and compared with those obtained at absolute scotopic thresholds for 25 individuals. A supplement study with 32 individuals both in the young (50) age groups for 6 months further established Mapcatsf's capacity to monitor changing levels of MP in individuals. As an overall outcome, high levels of repeatability and reliability were obtained in MPOD and LOD measurements establishing Mapcatsf as an instrument for use in clinical settings in the future.

  14. Predictors of phenotypic progression and disease onset in premanifest and early-stage Huntington's disease in the TRACK-HD study: analysis of 36-month observational data.

    PubMed

    Tabrizi, Sarah J; Scahill, Rachael I; Owen, Gail; Durr, Alexandra; Leavitt, Blair R; Roos, Raymund A; Borowsky, Beth; Landwehrmeyer, Bernhard; Frost, Chris; Johnson, Hans; Craufurd, David; Reilmann, Ralf; Stout, Julie C; Langbehn, Douglas R

    2013-07-01

    TRACK-HD is a multinational prospective observational study of Huntington's disease (HD) that examines clinical and biological findings of disease progression in individuals with premanifest HD (preHD) and early-stage HD. We aimed to describe phenotypic changes in these participants over 36 months and identify baseline predictors of progression. Individuals without HD but carrying the mutant huntingtin gene (classed as preHD-A if ≥10·8 years and preHD-B if <10·8 years from predicted onset), participants with early HD (classed as HD1 if they had a total functional capacity score of 11-13 and HD2 if they had a score of 7-10), and healthy control individuals were assessed at four study sites in the Netherlands, the UK, France, and Canada. We measured 36-month change for 3T MRI, clinical, cognitive, quantitative motor, and neuropsychiatric assessments and examined their prognostic value. We also assessed the relation between disease progression and the combined effect of CAG repeat length and age. All participants were analysed according to their baseline subgroups. Longitudinal results were analysed using a combination of repeated-measure weighted least squares models and, when examining risk of new diagnosis, survival analysis. At baseline, 366 participants were enrolled between Jan 17, and Aug 26, 2008, and of these 298 completed 36-month follow-up: 97 controls, 58 participants with preHD-A, 46 with preHD-B, 66 with HD1, and 31 with HD2. In the preHD-B group, several quantitative motor and cognitive tasks showed significantly increased rates of decline at 36 months, compared with controls, whereas few had at 24 months. Of the cognitive measures, the symbol digit modality test was especially sensitive (adjusted mean loss 4·11 points [95% CI 1·49-6·73] greater than controls; p=0·003). Among psychiatric indicators, apathy ratings specifically showed significant increases (0·34 points [95% CI 0·02-0·66] greater than controls; p=0·038). There was little evidence of reliable change in non-imaging measures in the preHD-A group, with the exception of the speeded tapping inter-tap interval (0·01 s [95% CI 0·01-0·02] longer than controls; p=0·0001). Several baseline imaging, quantitative motor, and cognitive measures had prognostic value, independent of age and CAG repeat length, for predicting subsequent clinical diagnosis in preHD. Of these, grey-matter volume and inter-tap interval were particularly sensitive (p=0·013 and 0·002, respectively). Longitudinal change in these two measures was also greater in participants with preHD who received a diagnosis of HD during the study compared with those who did not, after controlling for CAG repeat length and age-related risk (p=0·006 and 0·0003, respectively). In early HD, imaging, quantitative motor, and cognitive measures were predictive of decline in total functional capacity and tracked longitudinal change; also, neuropsychiatric changes consistent with frontostriatal pathological abnormalities were associated with this loss of functional capacity (problem behaviours assessment composite behaviour score p<0·0001). Age and CAG repeat length explained variance in longitudinal change of multimodal measures, with the effect more prominent in preHD. We have shown changes in several outcome measures in individuals with preHD over 36 months. These findings further our understanding of HD progression and have implications for clinical trial design. CHDI Foundation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. The suitability of lightfield camera depth maps for coordinate measurement applications

    NASA Astrophysics Data System (ADS)

    Rangappa, Shreedhar; Tailor, Mitul; Petzing, Jon; Kinnell, Peter; Jackson, Michael

    2015-12-01

    Plenoptic cameras can capture 3D information in one exposure without the need for structured illumination, allowing grey scale depth maps of the captured image to be created. The Lytro, a consumer grade plenoptic camera, provides a cost effective method of measuring depth of multiple objects under controlled lightning conditions. In this research, camera control variables, environmental sensitivity, image distortion characteristics, and the effective working range of two Lytro first generation cameras were evaluated. In addition, a calibration process has been created, for the Lytro cameras, to deliver three dimensional output depth maps represented in SI units (metre). The novel results show depth accuracy and repeatability of +10.0 mm to -20.0 mm, and 0.5 mm respectively. For the lateral X and Y coordinates, the accuracy was +1.56 μm to -2.59 μm and the repeatability was 0.25 μm.

  16. Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy.

    PubMed

    Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana

    2018-06-01

    To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.

  17. Chromogranin A and cortisol at intraoperative repeated noxious stimuli: Surgical stress in a dog model

    PubMed Central

    Hagman, Ragnvi; Stridsberg, Mats

    2015-01-01

    Objectives: Biomarkers representing sympathetic tone and the surgical stress response are measured to objectively evaluate surgical techniques and anaesthetic protocols. If a part of the intraoperative procedure is repeated on the contralateral organ, one animal may potentially serve as its own control and, if so, may minimize the problem of individual differences of the stress response to anaesthesia and surgery. This study aimed to investigate the use of chromogranin A for measurement of the intraoperative sympathetic tone. Additional aims were to investigate chromogranin A and cortisol as indicators of the intraoperative surgical stress response caused by repeated noxious stimuli in dogs subjected to ovariohysterectomy and thereby to investigate the possibility of one dog serving as its own control. Methods: Experiments were carried out on 10 dogs subjected to ovariohysterectomy. Perioperative blood samples (0–6) were collected after premedication, immediately before induction of anaesthesia (0), after induction of anaesthesia and before incision (1), before (2) and after (3) removal of the first ovary, after a 15-min pause before removal of the second ovary (4), after removal of the second ovary (5) and after closing the abdomen (6). Plasma chromogranin A and cortisol were analysed. Results: Plasma chromogranin A did not change. Plasma cortisol concentration did not change between before anaesthesia and opening of the abdomen. Plasma cortisol increased at removal of the first ovary. Cortisol did not change at removal of the second ovary but remained increased compared to initial sample. Conclusion: The results suggest chromogranin A is a poor indicator of intraoperative sympathetic tone during elective surgery in dogs. Cortisol measurement was useful for assessment of intraoperative noxious stimuli. However, at these test conditions, neither plasma chromogranin A nor plasma cortisol was useful for assessment of repeated intraoperative noxious stimuli where one dog served as its own control. PMID:26770773

  18. Empirical Tryout of a New Statistic for Detecting Temporally Inconsistent Responders.

    PubMed

    Kerry, Matthew J

    2018-01-01

    Statistical screening of self-report data is often advised to support the quality of analyzed responses - For example, reduction of insufficient effort responding (IER). One recently introduced index based on Mahalanobis's D for detecting outliers in cross-sectional designs replaces centered scores with difference scores between repeated-measure items: Termed person temporal consistency ( D 2 ptc ). Although the adapted D 2 ptc index demonstrated usefulness in simulation datasets, it has not been applied to empirical data. The current study addresses D 2 ptc 's low uptake by critically appraising its performance across three empirical applications. Independent samples were selected to represent a range of scenarios commonly encountered by organizational researchers. First, in Sample 1, a repeat-measure of future time perspective (FTP) inexperienced working adults (age >40-years; n = 620) indicated that temporal inconsistency was significantly related to respondent age and item reverse-scoring. Second, in repeat-measure of team efficacy aggregations, D 2 ptc successfully detected team-level inconsistency across repeat-performance cycles. Thirdly, the usefulness of the D 2 ptc was examined in an experimental study dataset of subjective life expectancy indicated significantly more stable responding in experimental conditions compared to controls. The empirical findings support D 2 ptc 's flexible and useful application to distinct study designs. Discussion centers on current limitations and further extensions that may be of value to psychologists screening self-report data for strengthening response quality and meaningfulness of inferences from repeated-measures self-reports. Taken together, the findings support the usefulness of the newly devised statistic for detecting IER and other extreme response patterns.

  19. The need to control for regression to the mean in social psychology studies.

    PubMed

    Yu, Rongjun; Chen, Li

    2014-01-01

    It is common in repeated measurements for extreme values at the first measurement to approach the mean at the subsequent measurement, a phenomenon called regression to the mean (RTM). If RTM is not fully controlled, it will lead to erroneous conclusions. The wide use of repeated measurements in social psychology creates a risk that an RTM effect will influence results. However, insufficient attention is paid to RTM in most social psychological research. Notable cases include studies on the phenomena of social conformity and unrealistic optimism (Klucharev et al., 2009, 2011; Sharot et al., 2011, 2012b; Campbell-Meiklejohn et al., 2012; Kim et al., 2012; Garrett and Sharot, 2014). In Study 1, 13 university students rated and re-rated the facial attractiveness of a series of female faces as a test of the social conformity effect (Klucharev et al., 2009). In Study 2, 15 university students estimated and re-estimated their risk of experiencing a series of adverse life events as a test of the unrealistic optimism effect (Sharot et al., 2011). Although these studies used methodologies similar to those used in earlier research, the social conformity and unrealistic optimism effects were no longer evident after controlling for RTM. Based on these findings we suggest several ways to control for the RTM effect in social psychology studies, such as adding the initial rating as a covariate in regression analysis, selecting a subset of stimuli for which the participant' initial ratings were matched across experimental conditions, and using a control group.

  20. Longitudinal Assessment of Effort-Reward Imbalance and Job Strain Across Pregnancy: A Preliminary Study.

    PubMed

    Meyer, John D; Muntaner, Carles; O'Campo, Patricia; Warren, Nicolas

    2016-07-01

    To assess longitudinal changes in occupational effort-reward imbalance (ERI) and demand-control (DC) scores across pregnancy and examine associations with blood pressure (BP) during pregnancy. A pilot repeated-measures survey was administered four times to a sample of working women across pregnancy using the ERI and DC instruments. Demographic data and blood pressure measurements were collected at each interval. Growth mixture modeling was used to examine trajectories of change in occupational characteristics. Associations with BP were examined using repeated-measures linear regression models. ERI model components (effort, reward, and overcommitment) all declined across pregnancy while job control remained stable. Increasing ERI trajectory was associated with higher systolic BP (b = 8.8; p < 0.001) as was high overcommitment; declining ERI also showed a lesser association with higher BP. Associations between DC trajectories and BP were much smaller, and non-significant once controlled for overcommitment. Self-assessed efforts, rewards, and overcommitment at work decline across pregnancy in our participants, while job control remains stable. Replication in a more diverse pregnant working population is warranted to confirm these results. These preliminary data suggest that further investigation into the factors that may be linked with improved work psychosocial climate during pregnancy may be useful in order to improve pregnancy outcomes.

  1. Longitudinal assessment of effort-reward imbalance and job strain across pregnancy: A preliminary study

    PubMed Central

    Meyer, John D; Muntaner, Carles; O'Campo, Patricia; Warren, Nicolas

    2016-01-01

    Objectives To assess longitudinal changes in occupational effort-reward imbalance (ERI) and demand-control (DC) scores across pregnancy and examine associations with blood pressure (BP) during pregnancy. Methods A pilot repeated-measures survey was administered four times to a sample of working women across pregnancy using the ERI and DC instruments. Demographic data and blood pressure measurements were collected at each interval. Growth mixture modeling was used to examine trajectories of change in occupational characteristics. Associations with BP were examined using repeated-measures linear regression models. Results ERI model components (effort, reward, and overcommitment) all declined across pregnancy while job control remained stable. Increasing ERI trajectory was associated with higher systolic BP (b=8.8; p<0.001) as was high overcommitment; declining ERI also showed a smaller association with higher BP. Associations between DC trajectories and BP were much smaller, and non-significant once controlled for overcommitment. Conclusions Self-assessed efforts, rewards, and overcommitment at work decline across pregnancy in our participants, while job control remains stable. Replication in a more diverse pregnant working population is warranted to confirm these results. These preliminary data suggest that further investigation into the factors that may be linked with improved work psychosocial climate during pregnancy may be useful in order to improve pregnancy outcomes. PMID:26948376

  2. Psychophysical and ergogenic effects of synchronous music during treadmill walking.

    PubMed

    Karageorghis, Costas I; Mouzourides, Denis A; Priest, David-Lee; Sasso, Tariq A; Morrish, Daley J; Walley, Carolyn J

    2009-02-01

    The present study examined the impact of motivational music and oudeterous (neutral in terms of motivational qualities) music on endurance and a range of psychophysical indices during a treadmill walking task. Experimental participants (N=30; mean age=20.5 years, SD=1.0 years) selected a program of either pop or rock tracks from artists identified in an earlier survey. They walked to exhaustion, starting at 75% maximal heart rate reserve, under conditions of motivational synchronous music, oudeterous synchronous music, and a no-music control. Dependent measures included time to exhaustion, ratings of perceived exertion (RPE), and in-task affect (both recorded at 2-min intervals), and exercise-induced feeling states. A one-way repeated measures ANOVA was used to analyze time to exhaustion data. Two-way repeated measures (Music Condition ? Trial Point) ANOVAs were used to analyze in-task measures, whereas a one-way repeated measures MANOVA was used to analyze the exercise-induced feeling states data. Results indicated that endurance was increased in both music conditions and that motivational music had a greater ergogenic effect than did oudeterous music (p<.01). In addition, in-task affect was enhanced by motivational synchronous music when compared with control throughout the trial (p<.01). The experimental conditions did not impact significantly (p>.05) upon RPE or exercise-induced feeling states, although a moderate effect size was recorded for the latter (etap2=.09). The present results indicate that motivational synchronous music can elicit an ergogenic effect and enhance in-task affect during an exhaustive endurance task.

  3. Repeated electromagnetic induction measurements for mapping soil moisture at the field scale: validation with data from a wireless soil moisture monitoring network

    NASA Astrophysics Data System (ADS)

    Martini, Edoardo; Werban, Ulrike; Zacharias, Steffen; Pohle, Marco; Dietrich, Peter; Wollschläger, Ute

    2017-01-01

    Electromagnetic induction (EMI) measurements are widely used for soil mapping, as they allow fast and relatively low-cost surveys of soil apparent electrical conductivity (ECa). Although the use of non-invasive EMI for imaging spatial soil properties is very attractive, the dependence of ECa on several factors challenges any interpretation with respect to individual soil properties or states such as soil moisture (θ). The major aim of this study was to further investigate the potential of repeated EMI measurements to map θ, with particular focus on the temporal variability of the spatial patterns of ECa and θ. To this end, we compared repeated EMI measurements with high-resolution θ data from a wireless soil moisture and soil temperature monitoring network for an extensively managed hillslope area for which soil properties and θ dynamics are known. For the investigated site, (i) ECa showed small temporal variations whereas θ varied from very dry to almost saturation, (ii) temporal changes of the spatial pattern of ECa differed from those of the spatial pattern of θ, and (iii) the ECa-θ relationship varied with time. Results suggest that (i) depending upon site characteristics, stable soil properties can be the major control of ECa measured with EMI, and (ii) for soils with low clay content, the influence of θ on ECa may be confounded by changes of the electrical conductivity of the soil solution. Further, this study discusses the complex interplay between factors controlling ECa and θ, and the use of EMI-based ECa data with respect to hydrological applications.

  4. Association of elevated blood pressure and impaired vasorelaxation in experimental Sprague-Dawley rats fed with heated vegetable oil

    PubMed Central

    2010-01-01

    Background Poor control of blood pressure leads to hypertension which is a major risk factor for development of cardiovascular disease. The present study aimed to explore possible mechanisms of elevation in blood pressure following consumption of heated vegetable oil. Methods Forty-two male Sprague-Dawley rats were equally divided into six groups: Group I (control) - normal rat chow, Group II - fresh soy oil, Group III - soy oil heated once, Group IV - soy oil heated twice, Group V - soy oil heated five times, Group VI - soy oil heated ten times. Blood pressure was measured at the baseline level and at a monthly interval for six months. Plasma nitric oxide, heme oxygenase and angiotensin-converting enzyme levels were measured prior to treatment, at month-three and month-six later. At the end of treatment, the rats were sacrificed and thoracic aortas were taken for measurement of vascular reactivity. Results Blood pressure increased significantly (p < 0.01) in the repeatedly heated oil groups compared to the control and fresh soy oil groups. Consumption of diet containing repeatedly heated oil resulted higher plasma angiotensin-converting enzyme level and lower nitric oxide content and heme oxygenase concentration. Reheated soy oil groups exhibited attenuated relaxation in response to acetylcholine or sodium nitroprusside, and greater contraction to phenylephrine. Conclusion As a result of consumption of repeatedly heated soy oil, an elevation in blood pressure was observed which may be due to the quantitative changes in endothelium dependent and independent factors including enzymes directly involved in the regulation of blood pressure. PMID:20573259

  5. Mediation of the Relationship between Maternal Phthalate Exposure and Preterm Birth by Oxidative Stress with Repeated Measurements across Pregnancy.

    PubMed

    Ferguson, Kelly K; Chen, Yin-Hsiu; VanderWeele, Tyler J; McElrath, Thomas F; Meeker, John D; Mukherjee, Bhramar

    2017-03-01

    Mediation analysis is useful for understanding mechanisms and has been used minimally in the study of the environment and disease. We examined mediation of the association between phthalate exposure during pregnancy and preterm birth by oxidative stress. This nested case-control study of preterm birth ( n = 130 cases, 352 controls) included women who delivered in Boston, Massachusestts, from 2006 through 2008. Phthalate metabolites and 8-isoprostane, an oxidative stress biomarker, were measured in urine from three visits in pregnancy. We applied four counterfactual mediation methods: method 1, utilizing exposure and mediator averages; method 2, using averages but allowing for an exposure-mediator interaction; method 3, incorporating longitudinal measurements of the exposure and mediator; and method 4, using longitudinal measurements and allowing for an exposure-mediator interaction. We observed mediation of the associations between phthalate metabolites and all preterm birth by 8-isoprostane, with the greatest estimated proportion mediated observed for spontaneous preterm births specifically. Fully utilizing repeated measures of the exposure and mediator improved precision of indirect (i.e., mediated) effect estimates, and including an exposure-mediator interaction increased the estimated proportion mediated. For example, for mono(2-ethyl-carboxy-propyl) phthalate (MECPP), a metabolite of di(2-ethylhexyl) phthalate (DEHP), the percent of the total effect mediated by 8-isoprostane increased from 47% to 60% with inclusion of an exposure-mediator interaction term, in reference to a total adjusted odds ratio of 1.67 or 1.48, respectively. This demonstrates mediation of the phthalate-preterm birth relationship by oxidative stress, and the utility of complex regression models in capturing mediated associations when repeated measures of exposure and mediator are available and an exposure-mediator interaction may exist. Citation: Ferguson KK, Chen YH, VanderWeele TJ, McElrath TF, Meeker JD, Mukherjee B. 2017. Mediation of the relationship between maternal phthalate exposure and preterm birth by oxidative stress with repeated measurements across pregnancy. Environ Health Perspect 125:488-494; http://dx.doi.org/10.1289/EHP282.

  6. Performance evaluation of the microINR® point-of-care INR-testing system.

    PubMed

    Joubert, J; van Zyl, M C; Raubenheimer, J

    2018-04-01

    Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.

  7. Could ionizing radiation forestall cauliflower ear?

    PubMed

    Hwang, K; Kim, C W; Lee, S I; Park, I S; Kim, W C; Loh, J J

    2001-02-01

    Repeated trauma to the ear very often results in "cauliflower ear." Many methods have been suggested to prevent an injured ear from demonstrating a cauliflowerlike deformity. The principles of treatment are evacuation of the hematoma, control of the reaccumulation of fluid, and maintenance of the cartilage contour. The authors studied the effect of ionizing radiation on deformed rabbit ears induced by repeated trauma. Twenty ears (10 rabbits) were used in the experiment. The animals were divided into four groups (control, preradiation, low dose, and high dose). Hematoma was produced by pounding the lateral side of the auricle 10 times with a 50-g weight at a height of 15 cm. The thickness of the injured and uninjured sites was measured, and histological analysis was performed for each group. The thickness of the ears of the irradiated groups was significantly less than the control group. The authors think that radiation treatment of repeatedly injured ears could prevent ear deformity, and could possibly be an adjunctive form of management of cauliflower ear in addition to hematoma evacuation and compression therapy.

  8. Dopamine D4 Receptor Gene Polymorphism in a Sample of Egyptian Children With Attention-Deficit Hyperactivity Disorder (ADHD).

    PubMed

    ElBaz Mohamed, Farida; Kamal, Tarek Mostafa; Zahra, Sally Soliman; Khfagy, Mona Abdel Hakiem; Youssef, Azza Mohamed

    2017-02-01

    This study aimed to detect DRD4 receptor gene polymorphisms in attention-deficit hyperactivity disorder (ADHD) children and to correlate their phenotype-genotype. Fifty children with ADHD were diagnosed by Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, criteria and were subjected to Conners Parent Rating Scale. All cases and controls were subjected to history taking, physical examination, IQ assessment, and dopamine receptor D4 (DRD4) exon 3 genotyping. The 7-repeat allele was present only in controls, whereas 2-repeat allele was present in the ADHD children (heterozygous 2-repeat allele in 16% and homozygous in 26% of cases). Eight percent of cases had homozygous 4-repeat allele vs 28% of controls, whereas 10% of cases had heterozygous 4-repeat allele vs 6% of controls, with its predominance in controls. The 2-repeat and 4-repeat alleles have been associated with more inattention, hyperactivity, and impulsivity phenotypes. In conclusion, children with ADHD had a significant presence of the 2-repeat allele and absence of the 7-repeat allele.

  9. Cycling induced by electrical stimulation improves motor recovery in postacute hemiparetic patients: a randomized controlled trial.

    PubMed

    Ambrosini, Emilia; Ferrante, Simona; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Molteni, Franco

    2011-04-01

    This study assessed whether cycling induced by functional electrical stimulation (FES) was more effective than passive cycling with placebo stimulation in promoting motor recovery and walking ability in postacute hemiparetic patients. In a double-blind, randomized, controlled trial, 35 patients were included and randomized to receive FES-induced cycling training or placebo FES cycling. The 4-week treatment consisted of 20 sessions lasting 25 minutes each. Primary outcome measures included the leg subscale of the Motricity Index and gait speed during a 50-meter walking test. Secondary outcomes were the Trunk Control Test, the Upright Motor Control Test, the mean work produced by the paretic leg, and the unbalance in mechanical work between paretic and nonparetic legs during voluntary pedaling. Participants were evaluated before training, after training, and at 3- to 5-month follow-up visits. No significant differences were found between groups at baseline. Repeated-measures ANOVA (P<0.05) revealed significant increases in Motricity Index, Trunk Control Test, Upright Motor Control Test, gait speed, and mean work of the paretic leg after training and at follow-up assessments for FES-treated patients. No outcome measures demonstrated significant improvements after training in the placebo group. Both groups showed no significant differences between assessments after training and at follow-up. A main effect favoring FES-treated patients was demonstrated by repeated-measures ANCOVA for Motricity Index (P<0.001), Trunk Control Test (P=0.001), Upright Motor Control Test (P=0.005), and pedaling unbalance (P=0.038). The study demonstrated that 20 sessions of FES cycling training significantly improved lower extremity motor functions and accelerated the recovery of overground locomotion in postacute hemiparetic patients. Improvements were maintained at follow-up.

  10. One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis

    PubMed Central

    Wang, Qing-qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li

    2017-01-01

    Objective This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. Method A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Result Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Conclusion Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research. PMID:29049323

  11. One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis.

    PubMed

    Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li

    2017-01-01

    This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.

  12. A theory-based online health behaviour intervention for new university students (U@Uni:LifeGuide): results from a repeat randomized controlled trial.

    PubMed

    Cameron, David; Epton, Tracy; Norman, Paul; Sheeran, Paschal; Harris, Peter R; Webb, Thomas L; Julious, Steven A; Brennan, Alan; Thomas, Chloe; Petroczi, Andrea; Naughton, Declan; Shah, Iltaf

    2015-12-07

    This paper reports the results of a repeat trial assessing the effectiveness of an online theory-based intervention to promote healthy lifestyle behaviours in new university students. The original trial found that the intervention reduced the number of smokers at 6-month follow-up compared with the control condition, but had non-significant effects on the other targeted health behaviours. However, the original trial suffered from low levels of engagement, which the repeat trial sought to rectify. Three weeks before staring university, all incoming undergraduate students at a large university in the UK were sent an email inviting them to participate in the study. After completing a baseline questionnaire, participants were randomly allocated to intervention or control conditions. The intervention consisted of a self-affirmation manipulation, health messages based on the theory of planned behaviour and implementation intention tasks. Participants were followed-up 1 and 6 months after starting university. The primary outcome measures were portions of fruit and vegetables consumed, physical activity levels, units of alcohol consumed and smoking status at 6-month follow-up. The study recruited 2,621 students (intervention n=1346, control n=1275), of whom 1495 completed at least one follow-up (intervention n=696, control n=799). Intention-to-treat analyses indicated that the intervention had a non-significant effect on the primary outcomes, although the effect of the intervention on fruit and vegetable intake was significant in the per-protocol analyses. Secondary analyses revealed that the intervention had significant effects on having smoked at university (self-report) and on a biochemical marker of alcohol use. Despite successfully increasing levels of engagement, the intervention did not have a significant effect on the primary outcome measures. The relatively weak effects of the intervention, found in both the original and repeat trials, may be due to the focus on multiple versus single health behaviours. Future interventions targeting the health behaviour of new university students should therefore focus on single health behaviours. Current Controlled Trials ISRCTN07407344 .

  13. [Effect of repeated fasting/refeeding on body weight control and energy balance regulation in rats].

    PubMed

    Wu, Bo; Du, Youai; Liu, Chongbin; Du, Zhou; Xiao, Min; Lu, Bo

    2010-09-01

    To investigate the changes of expression on leptin, a series of neuroendocrine factors and hormones associated with body weight control and energy balance regulation of rats, which were treated with repeated fasting/refeeding and followed by fed with high fat diet. Designing a repeated fasting/refeeding rats model (RFR) fed with basic stock diet on repeated cycles of 1 d fasting and 1 d refeeding for 6 weeks. The rats in RFR-LF/ HF group were switched to a high fat diet and fed the diet every day for another 6 weeks. The control rats were randomly divided into 3 groups, control group, high-fat diet (HF) group and common fat diet (CF) group. The rats in HF and CF group were killed by the end of the 12th week. The body weight, Lee's index, body fat content and serum lipid, GH, T4, leptin, insulin, and plasma ACTH levels were measured. The expression of NPY and POMC mRNA in hypothalamus were detected by reverse transcription chain reaction (RT-PCR). The Lee's index, body fat content, serum TC, TG, LDL, leptin and insulin levels of RFR-LF/HF group were lower significantly than those of HF group whereas higher significantly than those of CF group. The expression of NPY mRNA of RFR-LF/HF group were higher significantly than those of HF and CF groups, while the expression of POMC mRNA was lower significantly than that of HF and CF groups. The feeding pattern of repeated fasting/refeeding can decrease the degree of obesity induced by high fat diet, and also reduce the leptin and insulin resistance, but cause serious disturbance of the expression of neuroendocrine peptides in the central nervous system of rat.

  14. Remote sensing and disease control in China: past, present and future

    PubMed Central

    2013-01-01

    Satellite measurements have distinct advantages over conventional ground measurements because they can collect the information repeatedly and automatically. Since 1970 globally and 1985 in China, the availability of remote sensing (RS) techniques has steadily grown and they are becoming increasingly important to improve our understanding of human health. This paper gives the first detailed overview on the developments of RS applications for disease control in China. The problems, challenges and future directions are also discussed with an aim of guiding prospective studies. PMID:23311958

  15. Design and analysis of an automatic method of measuring silicon-controlled-rectifier holding current

    NASA Technical Reports Server (NTRS)

    Maslowski, E. A.

    1971-01-01

    The design of an automated SCR holding-current measurement system is described. The circuits used in the measurement system were designed to meet the major requirements of automatic data acquisition, reliability, and repeatability. Performance data are presented and compared with calibration data. The data verified the accuracy of the measurement system. Data taken over a 48-hr period showed that the measurement system operated satisfactorily and met all the design requirements.

  16. Fetal Microsatellite in the Heme Oxygenase 1 Promoter Is Associated With Severe and Early-Onset Preeclampsia.

    PubMed

    Kaartokallio, Tea; Utge, Siddheshwar; Klemetti, Miira M; Paananen, Jussi; Pulkki, Kari; Romppanen, Jarkko; Tikkanen, Ilkka; Heinonen, Seppo; Kajantie, Eero; Kere, Juha; Kivinen, Katja; Pouta, Anneli; Lakkisto, Päivi; Laivuori, Hannele

    2018-01-01

    Preeclampsia is a vascular pregnancy disorder that often involves impaired placental development. HO-1 (heme oxygenase 1, encoded by HMOX1 ) is a stress response enzyme crucial for endothelial and placental function. Long version of the guanine-thymine (GT n ) microsatellite in the HMOX1 promoter decreases HO-1 expression, and the long maternal repeat is associated with late-onset preeclampsia. Our aim was to study whether the length of fetal repeat is associated with mother's preeclampsia, whether the length of fetal and maternal repeats affect HO-1 levels in placenta and maternal serum, and whether HO-1 levels are altered in preeclampsia. We genotyped the repeat in the cord blood of 609 preeclamptic and 745 nonpreeclamptic neonates. HO-1 levels were measured in 36 placental samples, and in the first (222 cases/243 controls) and third (176 cases/53 controls) pregnancy trimester serum samples using enzyme-linked immunosorbent assay. The long fetal GT n repeat was associated with preeclampsia and its severe and early-onset subtypes. Interaction analysis suggested the maternal and fetal effects to be independent. Placental or serum HO-1 levels were not altered in preeclamptics, possibly reflecting heterogeneity of preeclampsia. Carriers of the long fetal and maternal repeats had lower placental and serum HO-1 levels, respectively, providing functional evidence for the association. We conclude that the long fetal GT n repeat may increase mother's risk for especially severe and early-onset preeclampsia. The fetal and maternal risk alleles likely predispose to different disease subtypes. © 2017 American Heart Association, Inc.

  17. Repeatability of Central Corneal Thickness Measurement Using Rotating Scheimpflug Camera in Dry and Normal Eyes.

    PubMed

    Lee, Jong-Hyuck; Kim, Jae Hyuck; Kim, Sun Woong

    2017-02-27

    To compare the repeatability of central corneal thickness (CCT) measurement using the Pentacam between dry eyes and healthy eyes, as well as to investigate the effect of artificial tears on CCT measurement. The corneal thicknesses of 34 patients with dry eye and 28 healthy subjects were measured using the Pentacam. One eye from each subject was assigned randomly to a repeatability test, wherein a single operator performed three successive CCT measurements time points-before and 5 min after instillation of one artificial teardrop. The repeatability of measurements was assessed using the coefficient of repeatability and the intraclass correlation coefficient. The coefficient of repeatability values of the CCT measurements in dry and healthy eyes were 24.36 and 10.69 μm before instillation, and 16.85 and 9.72 μm after instillation, respectively. The intraclass correlation coefficient was higher in healthy eyes than that of in dry eyes (0.987 vs. 0.891), and it had improved significantly in dry eyes (0.948) after instillation of one artificial teardrop. The CCT measurement fluctuated in dry eyes (repeated-measures analysis of variance, P<0.001), whereas no significant changes were detected in healthy eyes, either before or after artificial tear instillation. Central corneal thickness measurement is less repeatable in dry eyes than in healthy eyes. Artificial tears improve the repeatability of CCT measurements obtained using the Pentacam in dry eyes.

  18. Specimen coordinate automated measuring machine/fiducial automated measuring machine

    DOEpatents

    Hedglen, Robert E.; Jacket, Howard S.; Schwartz, Allan I.

    1991-01-01

    The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.

  19. What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?

    PubMed

    Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E

    2018-03-01

    Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values <40 mg/dL, 58% of deleted values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values <40 mg/dL could decrease reported rates of severe hypoglycemia by as much as 40%. This project demonstrates that operators are frequently able to identify POC BG values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.

  20. Interobserver repeatability of measurements on computed tomography images of lax canine hip joints from youth to maturity.

    PubMed

    Lopez, Mandi J; Davis, Kechia M; Jeffrey-Borger, Susan L; Markel, Mark D; Rettenmund, Christy

    2009-12-01

    To determine interobserver repeatability of measurements on computed tomography (CT) images of lax canine hip joints at different ages and in the presence of degenerative joint disease at maturity. Longitudinal observational investigation. Sibling crossbreed hounds. Pelvic CT was performed at 20, 24, 32, 48, 68, and 104 weeks of age. Measures were performed on 3 contiguous two-dimensional (2D) transverse CT images of both hips at each time point by 3 investigators. Center-edge angle (CEA), horizontal toit externe angle (HTEA), ventral (VASA), dorsal (DASA), and horizontal (HASA) acetabular sector angles, acetabular index (AI), and percent femoral head coverage (CPC) were measured. Interobserver repeatability was quantified with the intraclass correlation coefficient (ICC). Satisfactory repeatability was considered when ICC >or=0.75. DASA, CEA, and CPC were repeatable in all age groups. HASA and HTEA were repeatable for all but 1 time point. At 20 weeks of age, all measures but AI were repeatable, and at 104 weeks of age, DASA, CEA, CPC, and HASA were repeatable. Measures were repeatable in hips with and without degenerative changes with the exceptions of AI and HASA in normal hips and VASA and HTEA in osteoarthritic hips. Most 2D CT measurements examined were repeatable regardless of age or joint disease. Two-dimensional CT measures may augment current techniques for assessing joint changes in lax canine hips.

  1. Office blood pressure measurement alone often misclassifies treatment status in children with primary hypertension.

    PubMed

    Samuel, Joyce P; Bell, Cynthia S; Hebert, Sean A; Varughese, Arun; Samuels, Joshua A; Tyson, Jon E

    2017-12-01

    Clinicians frequently rely on office blood pressure (BP) measurements alone to assess hypertension control, despite widespread acceptance of 24-h ambulatory blood pressure monitoring (ABPM) as the reference standard in the initial diagnosis of hypertension. This study was designed to investigate how often the hypertensive status differed between concurrent office BP versus ABPM measurements, and whether any patient-specific characteristics predict the risk for misclassification by office BP. This study evaluated 42 children with primary hypertension who underwent repeated ambulatory monitoring (190 total recordings) with concurrent office BP measurement as part of their participation in n-of-1 trials. In nearly 40% of the visits, the treatment status by office measurement was opposite to the status by ambulatory monitoring. Office BP underestimated the ambulatory hypertensive status (masked uncontrolled hypertension) in 25% of visits and overestimated ambulatory BP (white coat effect) in 14% of visits. The difference between office BP and ambulatory monitoring was consistent within patients across repeated visits. Patients whose office measurement underestimated or overestimated the ambulatory BP at the first visit were more likely to show persistent discrepancy at subsequent visits. The underuse of ambulatory monitoring in management decisions of children treated for primary hypertension may result in systematic misclassification of hypertension control.

  2. Behavioural and physiological measures indicate subtle variations in the emotional valence of young pigs.

    PubMed

    Leliveld, Lisette M C; Düpjan, Sandra; Tuchscherer, Armin; Puppe, Birger

    2016-04-01

    In the study of animal emotions, emotional valence has been found to be difficult to measure. Many studies of farm animals' emotions have therefore focussed on the identification of indicators of strong, mainly negative, emotions. However, subtle variations in emotional valence, such as those caused by rather moderate differences in husbandry conditions, may also affect animals' mood and welfare when such variations occur consistently. In this study, we investigated whether repeated moderate aversive or rewarding events could lead to measurable differences in emotional valence in young, weaned pigs. We conditioned 105 female pigs in a test arena to either a repeated startling procedure (sudden noises or appearances of objects) or a repeated rewarding procedure (applesauce, toy and straw) over 11 sessions. Control pigs were also regularly exposed to the same test arena but without conditioning. Before and after conditioning, we measured heart rate and its variability as well as the behavioural reactions of the subjects in the test arena, with a special focus on detailed acoustic analyses of their vocalisations. The behavioural and heart rate measures were analysed as changes compared to the baseline values before conditioning. A limited number of the putative indicators of emotional valence were affected by the conditioning. We found that the negatively conditioned pigs showed changes that were significantly different from those in control pigs, namely a decrease in locomotion and an increase in standing. The positively conditioned pigs, however, showed a stronger increase in heart rate and a smaller decrease in SDNN (a heart rate variability parameter indicating changes in autonomic regulation) compared to the controls. Compared to the negatively conditioned pigs, the positively conditioned pigs produced fewer vocalisations overall as well as fewer low-frequency grunts but more high-frequency grunts. The low-frequency grunts of the negatively conditioned pigs also showed lower frequency parameters (bandwidth, maximum frequency, 25% and 50% quartiles) compared to those of the positively conditioned pigs. In any of the statistically significant results, the conditioning accounted for 1.5-11.9% of variability in the outcome variable. Hence, we conclude that repeated moderate aversive and rewarding events have weak but measurable effects on some aspects of behaviour and physiology in young pigs, possibly indicating changes in emotional valence, which could ultimately affect their welfare. The combination of ethophysiological indicators, i.e., the concurrent examination of heart rate measures, behavioural responses and especially vocalisation patterns, as used in the current study, might be a useful way of examining subtle effects on emotional valence in further studies. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: a possible trait marker

    PubMed Central

    Homan, Philipp; Kindler, Jochen; Hauf, Martinus; Walther, Sebastian; Hubl, Daniela; Dierks, Thomas

    2013-01-01

    Background: The left superior temporal gyrus (STG) has been suggested to play a key role in auditory verbal hallucinations (AVH) in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant AVH and 19 healthy controls underwent perfusion magnetic resonance (MR) imaging with arterial spin labeling (ASL). Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS) between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF), which consisted of the regional CBF measurement in the left STG and the global CBF measurement in the whole brain. Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001) and to the global CBF in patients (p < 0.004) at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007), and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001). After TMS, PANSS (p = 0.003) and PSYRATS (p = 0.01) scores decreased significantly in patients. Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of AVH in schizophrenia. PMID:23805093

  4. Effort-Based Decision-Making Paradigms for Clinical Trials in Schizophrenia: Part 1—Psychometric Characteristics of 5 Paradigms

    PubMed Central

    Reddy, L. Felice; Horan, William P.; Barch, Deanna M.; Buchanan, Robert W.; Dunayevich, Eduardo; Gold, James M.; Lyons, Naomi; Marder, Stephen R.; Treadway, Michael T.; Wynn, Jonathan K.; Young, Jared W.; Green, Michael F.

    2015-01-01

    Impairments in willingness to exert effort contribute to the motivational deficits characteristic of the negative symptoms of schizophrenia. The current study evaluated the psychometric properties of 5 new or adapted paradigms to determine their suitability for use in clinical trials of schizophrenia. This study included 94 clinically stable participants with schizophrenia and 40 healthy controls. The effort-based decision-making battery was administered twice to the schizophrenia group (baseline, 4-week retest) and once to the control group. The 5 paradigms included 1 that assesses cognitive effort, 1 perceptual effort, and 3 that assess physical effort. Each paradigm was evaluated on (1) patient vs healthy control group differences, (2) test-retest reliability, (3) utility as a repeated measure (ie, practice effects), and (4) tolerability. The 5 paradigms showed varying psychometric strengths and weaknesses. The Effort Expenditure for Rewards Task showed the best reliability and utility as a repeated measure, while the Grip Effort Task had significant patient-control group differences, and superior tolerability and administration duration. The other paradigms showed weaker psychometric characteristics in their current forms. These findings highlight challenges in adapting effort and motivation paradigms for use in clinical trials. PMID:26142081

  5. Parenting, attention and externalizing problems: testing mediation longitudinally, repeatedly and reciprocally.

    PubMed

    Belsky, Jay; Pasco Fearon, R M; Bell, Brian

    2007-12-01

    Building on prior work, this paper tests, longitudinally and repeatedly, the proposition that attentional control processes mediate the effect of earlier parenting on later externalizing problems. Repeated independent measurements of all three constructs--observed parenting, computer-tested attentional control and adult-reported externalizing problems--were subjected to structural equation modeling using data from the large-scale American study of child care and youth development. Structural equation modeling indicated (a) that greater maternal sensitivity at two different ages (54 months, approximately 6 years) predicted better attentional control on the Continuous Performance Test (CPT) of attention regulation two later ages ( approximately 6/9 years); (2) that better attentional control at three different ages (54 months, approximately 6/9 years) predicted less teacher-reported externalizing problems at three later ages ( approximately 6/8/10 years); and (3) that attentional control partially mediated the effect of parenting on externalizing problems at two different lags (i.e., 54 months--> approximately 6 years--> approximately 8 years; approximately 6 years--> approximately 9 years--> approximately 10 years), though somewhat more strongly for the first. Additionally, (4) some evidence of reciprocal effects of attentional processes on parenting emerged (54 months--> approximately 6 years; approximately 6 years--> approximately 8 years), but not of problem behavior on attention. Because attention control partially mediates the effects of parenting on externalizing problems, intervention efforts could target both parenting and attentional processes.

  6. Effects of repeated transport on Holstein calf post-transport behavior and feed intake.

    PubMed

    Adams-Progar, A L; Friend, T H; Holub, G A; Krenek, A J; Garey, S M; Terrill, C L

    2015-02-01

    Previous studies have determined that stress causes decreases in feed intake and efficiency in livestock, but the effect of repeated transport on these parameters has not been well studied. This study determined how repeated transport affected calf post-transport behavior, feed intake, ADG, and feed conversion. Thirty-six 4-mo-old Holstein steer calves were housed in groups of 6 with each group randomly assigned to either transport or control treatments. Each calf was assigned to an individual Calan gate feeder and feed intake was recorded daily. Transport calves were transported for 6 h in their groups in a 7.3 by 2.4 m gooseneck trailer divided into 3 compartments, at an average density of 0.87 m/calf, every 7 d for 5 consecutive weeks. After return to their home pens, behavior was recorded for transported calves at 5-min intervals for 1 h. Calf ADG and feed conversion were analyzed in a mixed model ANOVA, whereas feed intake was analyzed as a repeated measure in a mixed model ANOVA. Post-transport, calves followed a pattern of drinking, eating, and then lying down. The highest (82 ± 5% calves) and lowest (0 ± 5% calves) incidences of eating behavior occurred 10 and 60 min post-transport, respectively. Control calves had a higher feed intake than transported calves overall (7.29 ± 0.22 kg for control and 6.91 ± 0.21 kg for transport; = 0.01), for the feeding posttreatment (6.78 ± 0.27 kg for control and 6.01 ± 0.28 kg for transport; = 0.007), and the day after treatment (7.83 ± 0.23 kg for control and 7.08 ± 0.15 kg for transport; = 0.02). Feed intake for the feeding post-transport for transport calves significantly decreased after the second transport but increased with each successive transport ( < 0.0001). Overall, control calves had higher ADG than transported calves (1.34 ± 0.13 kg/d for control and 1.15 ± 0.12 kg/d for transport; = 0.006). No significant difference ( = 0.12) between treatments was detected for feed conversion. These results suggest that calves exposed to repeated transport may decrease feed intake compared to nontransported calves as an initial response to transport; however, overall feed conversion was not affected and these Holstein calves may have quickly acclimated to repeated transport.

  7. A Genome-Wide Association Study Identifies a Novel Major Locus for Glycemic Control in Type 1 Diabetes, as Measured by Both A1C and Glucose

    PubMed Central

    Paterson, Andrew D.; Waggott, Daryl; Boright, Andrew P.; Hosseini, S. Mohsen; Shen, Enqing; Sylvestre, Marie-Pierre; Wong, Isidro; Bharaj, Bhupinder; Cleary, Patricia A.; Lachin, John M.; Below, Jennifer E.; Nicolae, Dan; Cox, Nancy J.; Canty, Angelo J.; Sun, Lei; Bull, Shelley B.

    2010-01-01

    OBJECTIVE Glycemia is a major risk factor for the development of long-term complications in type 1 diabetes; however, no specific genetic loci have been identified for glycemic control in individuals with type 1 diabetes. To identify such loci in type 1 diabetes, we analyzed longitudinal repeated measures of A1C from the Diabetes Control and Complications Trial. RESEARCH DESIGN AND METHODS We performed a genome-wide association study using the mean of quarterly A1C values measured over 6.5 years, separately in the conventional (n = 667) and intensive (n = 637) treatment groups of the DCCT. At loci of interest, linear mixed models were used to take advantage of all the repeated measures. We then assessed the association of these loci with capillary glucose and repeated measures of multiple complications of diabetes. RESULTS We identified a major locus for A1C levels in the conventional treatment group near SORCS1 (10q25.1, P = 7 × 10−10), which was also associated with mean glucose (P = 2 × 10−5). This was confirmed using A1C in the intensive treatment group (P = 0.01). Other loci achieved evidence close to genome-wide significance: 14q32.13 (GSC) and 9p22 (BNC2) in the combined treatment groups and 15q21.3 (WDR72) in the intensive group. Further, these loci gave evidence for association with diabetic complications, specifically SORCS1 with hypoglycemia and BNC2 with renal and retinal complications. We replicated the SORCS1 association in Genetics of Diabetes in Kidneys (GoKinD) study control subjects (P = 0.01) and the BNC2 association with A1C in nondiabetic individuals. CONCLUSIONS A major locus for A1C and glucose in individuals with diabetes is near SORCS1. This may influence the design and analysis of genetic studies attempting to identify risk factors for long-term diabetic complications. PMID:19875614

  8. The measurement of an aspherical mirror by three-dimensional nanoprofiler

    NASA Astrophysics Data System (ADS)

    Tokuta, Yusuke; Okita, Kenya; Okuda, Kohei; Kitayama, Takao; Nakano, Motohiro; Nakatani, Shun; Kudo, Ryota; Yamamura, Kazuya; Endo, Katsuyoshi

    2015-09-01

    Aspherical optical elements with high accuracy are important in several fields such as third-generation synchrotron radiation and extreme-ultraviolet lithography. Then the demand of measurement method for aspherical or free-form surface with nanometer resolution is rising. Our purpose is to develop a non-contact profiler to measure free-form surfaces directly with repeatability of figure error of less than 1 nm PV. To achieve this purpose we have developed three-dimensional Nanoprofiler which traces normal vectors of sample surface. The measurement principle is based on the straightness of LASER light and the accuracy of a rotational goniometer. This machine consists of four rotational stages, one translational stage and optical head which has the quadrant photodiode (QPD) and LASER head at optically equal position. In this measurement method, we conform the incident light beam to reflect the beam by controlling five stages and determine the normal vectors and the coordinates of the surface from signal of goniometers, translational stage and QPD. We can obtain three-dimensional figure from the normal vectors and the coordinates by a reconstruction algorithm. To evaluate performance of this machine we measure a concave aspherical mirror ten times. From ten results we calculate measurement repeatability, and we evaluate measurement uncertainty to compare the result with that measured by an interferometer. In consequence, the repeatability of measurement was 2.90 nm (σ) and the difference between the two profiles was +/-20 nm. We conclude that the two profiles was correspondent considering systematic errors of each machine.

  9. Recollection training and transfer effects in older adults: successful use of a repetition-lag procedure.

    PubMed

    Jennings, Janine M; Webster, Lauren M; Kleykamp, Bethea A; Dagenbach, Dale

    2005-09-01

    We examined an approach aimed at training consciously-controlled recollection, introduced by Jennings and Jacoby (2003) , for its ability to replicate and generalize. A continuous recognition task, requiring recollection to identify the occurrence of repeated items over gradually increasing lag intervals (number of intervening items between the first and second presentation of a repeated word), was given to a group of older adults twice a week for three weeks. Pre-and-post training performance was assessed on multiple measures and compared with a recognition practice and no contact control group. Recollection training proved successful; accurate identification of repeated items increased across a lag interval of 2 to 18 intervening items. Post-training gains following recollection training were found on n-back, self-ordered pointing, source discrimination and digit symbol substitution, but not with reading span or the CVLT-II. No changes were identified in the other groups. Gains from recollection training seem to transfer successfully in older adults.

  10. Social instigation and repeated aggressive confrontations in male Swiss mice: analysis of plasma corticosterone, CRF and BDNF levels in limbic brain areas.

    PubMed

    Fortes, Paula Madeira; Albrechet-Souza, Lucas; Vasconcelos, Mailton; Ascoli, Bruna Maria; Menegolla, Ana Paula; de Almeida, Rosa Maria M

    2017-01-01

    Agonistic behaviors help to ensure survival, provide advantage in competition, and communicate social status. The resident-intruder paradigm, an animal model based on male intraspecific confrontations, can be an ethologically relevant tool to investigate the neurobiology of aggressive behavior. To examine behavioral and neurobiological mechanisms of aggressive behavior in male Swiss mice exposed to repeated confrontations in the resident intruder paradigm. Behavioral analysis was performed in association with measurements of plasma corticosterone of mice repeatedly exposed to a potential rival nearby, but inaccessible (social instigation), or to 10 sessions of social instigation followed by direct aggressive encounters. Moreover, corticotropin-releasing factor (CRF) and brain-derived neurotrophic factor (BNDF) were measured in the brain of these animals. Control mice were exposed to neither social instigation nor aggressive confrontations. Mice exposed to aggressive confrontations exhibited a similar pattern of species-typical aggressive and non-aggressive behaviors on the first and the last session. Moreover, in contrast to social instigation only, repeated aggressive confrontations promoted an increase in plasma corticosterone. After 10 aggressive confrontation sessions, mice presented a non-significant trend toward reducing hippocampal levels of CRF, which inversely correlated with plasma corticosterone levels. Conversely, repeated sessions of social instigation or aggressive confrontation did not alter BDNF concentrations at the prefrontal cortex and hippocampus. Exposure to repeated episodes of aggressive encounters did not promote habituation over time. Additionally, CRF seems to be involved in physiological responses to social stressors.

  11. Thermal, cardiac and adrenergic responses to repeated local cooling.

    PubMed

    Janský, L; Matousková, E; Vávra, V; Vybíral, S; Janský, P; Jandová, D; Knízková, I; Kunc, P

    2006-01-01

    The aim of this study was to ascertain whether repeated local cooling induces the same or different adaptational responses as repeated whole body cooling. Repeated cooling of the legs (immersion into 12 degrees C water up to the knees for 30 min, 20 times during 4 weeks = local cold adaptation - LCA) attenuated the initial increase in heart rate and blood pressure currently observed in control subjects immersed in cold water up to the knees. After LCA the initial skin temperature decrease tended to be lower, indicating reduced vasoconstriction. Heart rate and systolic blood pressure appeared to be generally lower during rest and during the time course of cooling in LCA humans, when compared to controls. All these changes seem to indicate attenuation of the sympathetic tone. In contrast, the sustained skin temperature in different areas of the body (finger, palm, forearm, thigh, chest) appeared to be generally lower in LCA subjects than in controls (except for temperatures on the forehead). Plasma levels of catecholamines (measured 20 and 40 min after the onset of cooling) were also not influenced by local cold adaptation. Locally cold adapted subjects, when exposed to whole body cold water immersion test, showed no change in the threshold temperature for induction of cold thermogenesis. This indicates that the hypothermic type of cold adaptation, typically occurring after systemic cold adaptation, does not appear after local cold adaptation of the intensity used. It is concluded that in humans the cold adaptation due to repeated local cooling of legs induces different physiological changes than systemic cold adaptation.

  12. The potential benefits of repeated measure experiments for fish disease-challenge host-pathogen investigations.

    PubMed

    Hall, L Malcolm; Collins, Catherine; Collet, Bertrand

    2018-02-02

    The utility of molecular response data arising from in-vivo single and repeated measure fish disease-challenge experiments is compared. An in-silico 'experiment' involving the generation of two imaginary immune-molecule quantity response profiles over time for individual animals was carried out. Daily 'observed' molecule quantities were drawn from the 'known' individual response profiles to mimic the results of single and repeated measurement. The results indicate that repeated measure experiments are required to infer individual level response profiles, and that these experiments also provide more accurate summary statistics and data more suited to inferring the dependent ordering of the molecular response. Additionally repeated measure experiments utilise fewer animals than single measure experiments. These results are described alongside a discussion of experimental methodological issues pertinent to the adoption of aquatic animal repeated measure experimental designs. We conclude that investigators need to take particular care when making inferences from single measure experiments and that serious consideration should be given to using repeated measure experiments for in-vivo fish disease-challenge investigations. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  13. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    PubMed

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  14. The Motivating Influence of Retest and Repeated Dietary Counseling on Cholesterol Reduction

    NASA Technical Reports Server (NTRS)

    Taylor, P.; Townsend, J. C.; Villafana, C.; Arnoldi, L. B.

    1971-01-01

    An analysis was made of retest and followup counselling effects on the reduction of hypercholesterolemia levels in NASA employees. Criteria used to measure such control include motivation, age of patient, personality of patient, job stress, and physical exercise.

  15. Work, Gender, and Teaching.

    ERIC Educational Resources Information Center

    Apple, Michael W.

    1983-01-01

    The connections between class and gender must be recognized if attempts to rationalize and proletarianize teaching are to be understood. Behaviorally-specified curriculum, prepackaged programs, and repeated testing and accountability measures represent attempts by state governments and by male administrators to wrest control of instruction from a…

  16. The need to control for regression to the mean in social psychology studies

    PubMed Central

    Yu, Rongjun; Chen, Li

    2014-01-01

    It is common in repeated measurements for extreme values at the first measurement to approach the mean at the subsequent measurement, a phenomenon called regression to the mean (RTM). If RTM is not fully controlled, it will lead to erroneous conclusions. The wide use of repeated measurements in social psychology creates a risk that an RTM effect will influence results. However, insufficient attention is paid to RTM in most social psychological research. Notable cases include studies on the phenomena of social conformity and unrealistic optimism (Klucharev et al., 2009, 2011; Sharot et al., 2011, 2012b; Campbell-Meiklejohn et al., 2012; Kim et al., 2012; Garrett and Sharot, 2014). In Study 1, 13 university students rated and re-rated the facial attractiveness of a series of female faces as a test of the social conformity effect (Klucharev et al., 2009). In Study 2, 15 university students estimated and re-estimated their risk of experiencing a series of adverse life events as a test of the unrealistic optimism effect (Sharot et al., 2011). Although these studies used methodologies similar to those used in earlier research, the social conformity and unrealistic optimism effects were no longer evident after controlling for RTM. Based on these findings we suggest several ways to control for the RTM effect in social psychology studies, such as adding the initial rating as a covariate in regression analysis, selecting a subset of stimuli for which the participant' initial ratings were matched across experimental conditions, and using a control group. PMID:25620951

  17. 47 CFR 97.205 - Repeater station.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... case, the licensee of the non-coordinated repeater has primary responsibility to resolve the interference. (d) A repeater may be automatically controlled. (e) Ancillary functions of a repeater that are available to users on the input channel are not considered remotely controlled functions of the station...

  18. 47 CFR 97.205 - Repeater station.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... case, the licensee of the non-coordinated repeater has primary responsibility to resolve the interference. (d) A repeater may be automatically controlled. (e) Ancillary functions of a repeater that are available to users on the input channel are not considered remotely controlled functions of the station...

  19. 47 CFR 97.205 - Repeater station.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... case, the licensee of the non-coordinated repeater has primary responsibility to resolve the interference. (d) A repeater may be automatically controlled. (e) Ancillary functions of a repeater that are available to users on the input channel are not considered remotely controlled functions of the station...

  20. 47 CFR 97.205 - Repeater station.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... case, the licensee of the non-coordinated repeater has primary responsibility to resolve the interference. (d) A repeater may be automatically controlled. (e) Ancillary functions of a repeater that are available to users on the input channel are not considered remotely controlled functions of the station...

  1. 47 CFR 97.205 - Repeater station.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... case, the licensee of the non-coordinated repeater has primary responsibility to resolve the interference. (d) A repeater may be automatically controlled. (e) Ancillary functions of a repeater that are available to users on the input channel are not considered remotely controlled functions of the station...

  2. Repeatability and sensitivity of high resolution blood volume mapping in mouse kidney disease.

    PubMed

    Wang, Feng; Jiang, Rosie T; Tantawy, Mohammed Noor; Borza, Dorin B; Takahashi, Keiko; Gore, John C; Harris, Raymond C; Takahashi, Takamune; Quarles, C Chad

    2014-04-01

    To evaluate the repeatability of MRI-derived relative blood volume (RBV) measurements in mouse kidneys across subjects and days and to evaluate sensitivity of this approach to renal pathology. A 7 Tesla MRI system and an intravascular iron-oxide contrast agent were used to acquire spin-echo-based renal RBV maps in 10 healthy mice on 2 consecutive days. Renal RBV maps were also acquired in the Alport and unilateral ureteral obstruction mouse models of renal disease. The average renal RBV measured on consecutive days was 19.97 ± 1.50 and 19.86 ± 1.62, yielding a concordance correlation coefficient of 0.94, indicating that this approach is highly repeatable. In the disease models, the RBV values were regionally dissimilar and substantially lower than those found in control mice. In vivo renal iron-oxide-based RBV mapping in mice complements the physiological information obtained from conventional assays of kidney function and could shed new insights into the pathological mechanisms of kidney disease. Copyright © 2013 Wiley Periodicals, Inc.

  3. Comparing a single case to a control group - Applying linear mixed effects models to repeated measures data.

    PubMed

    Huber, Stefan; Klein, Elise; Moeller, Korbinian; Willmes, Klaus

    2015-10-01

    In neuropsychological research, single-cases are often compared with a small control sample. Crawford and colleagues developed inferential methods (i.e., the modified t-test) for such a research design. In the present article, we suggest an extension of the methods of Crawford and colleagues employing linear mixed models (LMM). We first show that a t-test for the significance of a dummy coded predictor variable in a linear regression is equivalent to the modified t-test of Crawford and colleagues. As an extension to this idea, we then generalized the modified t-test to repeated measures data by using LMMs to compare the performance difference in two conditions observed in a single participant to that of a small control group. The performance of LMMs regarding Type I error rates and statistical power were tested based on Monte-Carlo simulations. We found that starting with about 15-20 participants in the control sample Type I error rates were close to the nominal Type I error rate using the Satterthwaite approximation for the degrees of freedom. Moreover, statistical power was acceptable. Therefore, we conclude that LMMs can be applied successfully to statistically evaluate performance differences between a single-case and a control sample. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Serum organochlorine pesticide residues and risk of testicular germ cell carcinoma: a population-based case-control study.

    PubMed

    Biggs, Mary L; Davis, Mark D; Eaton, David L; Weiss, Noel S; Barr, Dana B; Doody, David R; Fish, Sherianne; Needham, Larry L; Chen, Chu; Schwartz, Stephen M

    2008-08-01

    Testicular germ cell carcinoma (TGCC) is the most common malignancy among men ages 20 to 34 years. Although the pathogenesis of TGCC is poorly understood, suboptimal androgen levels or impaired androgen signaling may play a role. Some persistent organochlorine pesticides commonly found in human tissue possess antiandrogenic properties. We examined whether the risk of TGCC is associated with serum levels of 11 organochlorine pesticides, including p,p'-DDE, and whether the p,p'-DDE-TGCC association is modified by CAG or GGN repeat polymorphisms in the androgen receptor gene. We conducted a population-based case-control study among 18- to 44-year-old male residents of three Washington State counties. Cases (n = 246) were diagnosed during 1999 to 2003 with a first, primary TGCC. Controls (n = 630) were men of similar age with no history of TGCC from the same population identified through random-digit telephone dialing. Questionnaires elicited information on demographic, medical, and lifestyle factors. A blood specimen provided serum for gas chromatography-high-resolution mass spectrometry analysis of organochlorine pesticide residues and DNA for genotyping. We observed no clear patterns between TGCC risk and concentrations of any of the organochlorines measured, nor did we observe that the risk associated with p,p'-DDE was modified by androgen receptor CAG (<23 versus > or =23 repeats) or GGN (<17 versus > or =17 repeats) genotype. This study does not provide support for the hypothesis that adult exposure to organochlorine pesticides is associated with risk of TGCC. Due to uncertainty regarding how well organochlorine levels measured in adulthood reflect exposures during early life, further research is needed using exposure measurements collected in utero or during infancy.

  5. A new method for sudden mechanical perturbation with axial load, to assess postural control in sitting and standing.

    PubMed

    Claus, Andrew P; Verrel, Julius; Pounds, Paul E I; Shaw, Renee C; Brady, Niamh; Chew, Min T; Dekkers, Thomas A; Hodges, Paul W

    2016-05-03

    Sudden application of load along a sagittal or coronal axis has been used to study trunk stiffness, but not axial (vertical) load. This study introduces a new method for sudden-release axial load perturbation. Prima facie validity was supported by comparison with standard mechanical systems. We report the response of the human body to axial perturbation in sitting and standing and within-day repeatability of measures. Load of 20% of body weight was released from light contact onto the shoulders of 22 healthy participants (10 males). Force input was measured via force transducers at shoulders, output via a force plate below the participant, and kinematics via 3-D motion capture. System identification was used to fit data from the time of load release to time of peak load-displacement, fitting with a 2nd-order mass-spring-damper system with a delay term. At peak load-displacement, the mean (SD) effective stiffness measured with this device for participants in sitting was 12.0(3.4)N/mm, and in standing was 13.3(4.2)N/mm. Peak force output exceeded input by 44.8 (10.0)% in sitting and by 30.4(7.9)% in standing. Intra-class correlation coefficients for within-day repeatability of axial stiffness were 0.58 (CI: -0.03 to 0.83) in sitting and 0.82(0.57-0.93) in standing. Despite greater degrees of freedom in standing than sitting, standing involved lesser time, downward displacement, peak output force and was more repeatable in defending upright postural control against the same axial loads. This method provides a foundation for future studies of neuromuscular control with axial perturbation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. The repeatability and reproducibility of the BioRID IIg in a repeatable laboratory seat based on a production car seat.

    PubMed

    Hynd, David; Depinet, Paul; Lorenz, Bernd

    2013-01-01

    The United Nations Economic Commission for Europe Informal Group on GTR No. 7 Phase 2 are working to define a build level for the BioRID II rear impact (whiplash) crash test dummy that ensures repeatable and reproducible performance in a test procedure that has been proposed for future legislation. This includes the specification of dummy hardware, as well as the development of comprehensive certification procedures for the dummy. This study evaluated whether the dummy build level and certification procedures deliver the desired level of repeatability and reproducibility. A custom-designed laboratory seat was made using the seat base, back, and head restraint from a production car seat to ensure a representative interface with the dummy. The seat back was reinforced for use in multiple tests and the recliner mechanism was replaced by an external spring-damper mechanism. A total of 65 tests were performed with 6 BioRID IIg dummies using the draft GTR No.7 sled pulse and seating procedure. All dummies were subject to the build, maintenance, and certification procedures defined by the Informal Group. The test condition was highly repeatable, with a very repeatable pulse, a well-controlled seat back response, and minimal observed degradation of seat foams. The results showed qualitatively reasonable repeatability and reproducibility for the upper torso and head accelerations, as well as for T1 Fx and upper neck Fx . However, reproducibility was not acceptable for T1 and upper neck Fz or for T1 and upper neck My . The Informal Group has not selected injury or seat assessment criteria for use with BioRID II, so it is not known whether these channels would be used in the regulation. However, the ramping-up behavior of the dummy showed poor reproducibility, which would be expected to affect the reproducibility of dummy measurements in general. Pelvis and spine characteristics were found to significantly influence the dummy measurements for which poor reproducibility was observed. It was also observed that the primary neck response in these tests was flexion, not extension. This correlates well with recent findings from Japan and the United States showing a correlation between neck flexion and injury in accident replication simulations and postmortem human subjects (PMHS) studies, respectively. The present certification tests may not adequately control front cervical spine bumper characteristics, which are important for neck flexion response. The certification sled test also does not include the pelvis and so cannot be used to control pelvis response and does not substantially load the lumbar bumpers and so does not control these parts of the dummy. The stiffness of all spine bumpers and of the pelvis flesh should be much more tightly controlled. It is recommended that a method for certifying the front cervical bumpers should be developed. Recommendations are also made for tighter tolerance on the input parameters for the existing certification tests.

  7. Altered effect of dopamine transporter 3'UTR VNTR genotype on prefrontal and striatal function in schizophrenia.

    PubMed

    Prata, Diana P; Mechelli, Andrea; Picchioni, Marco M; Fu, Cynthia H Y; Toulopoulou, Timothea; Bramon, Elvira; Walshe, Muriel; Murray, Robin M; Collier, David A; McGuire, Philip

    2009-11-01

    The dopamine transporter plays a key role in the regulation of central dopaminergic transmission, which modulates cognitive processing. Disrupted dopamine function and impaired executive processing are robust features of schizophrenia. To examine the effect of a polymorphism in the dopamine transporter gene (the variable number of tandem repeats in the 3' untranslated region) on brain function during executive processing in healthy volunteers and patients with schizophrenia. We hypothesized that this variation would have a different effect on prefrontal and striatal activation in schizophrenia, reflecting altered dopamine function. Case-control study. Psychiatric research center. Eighty-five subjects, comprising 44 healthy volunteers (18 who were 9-repeat carriers and 26 who were 10-repeat homozygotes) and 41 patients with DSM-IV schizophrenia (18 who were 9-repeat carriers and 23 who were 10-repeat homozygotes). Regional brain activation during word generation relative to repetition in an overt verbal fluency task measured by functional magnetic resonance imaging. Main effects of genotype and diagnosis on activation and their interaction were estimated with analysis of variance in SPM5. Irrespective of diagnosis, the 10-repeat allele was associated with greater activation than the 9-repeat allele in the left anterior insula and right caudate nucleus. Trends for the same effect in the right insula and for greater deactivation in the rostral anterior cingulate cortex were also detected. There were diagnosis x genotype interactions in the left middle frontal gyrus and left nucleus accumbens, where the 9-repeat allele was associated with greater activation than the 10-repeat allele in patients but not controls. Insular, cingulate, and striatal function during an executive task is normally modulated by variation in the dopamine transporter gene. Its effect on activation in the dorsolateral prefrontal cortex and ventral striatum is altered in patients with schizophrenia. This may reflect altered dopamine function in these regions in schizophrenia.

  8. ATXN2 trinucleotide repeat length correlates with risk of ALS.

    PubMed

    Sproviero, William; Shatunov, Aleksey; Stahl, Daniel; Shoai, Maryam; van Rheenen, Wouter; Jones, Ashley R; Al-Sarraj, Safa; Andersen, Peter M; Bonini, Nancy M; Conforti, Francesca L; Van Damme, Philip; Daoud, Hussein; Del Mar Amador, Maria; Fogh, Isabella; Forzan, Monica; Gaastra, Ben; Gellera, Cinzia; Gitler, Aaron D; Hardy, John; Fratta, Pietro; La Bella, Vincenzo; Le Ber, Isabelle; Van Langenhove, Tim; Lattante, Serena; Lee, Yi-Chung; Malaspina, Andrea; Meininger, Vincent; Millecamps, Stéphanie; Orrell, Richard; Rademakers, Rosa; Robberecht, Wim; Rouleau, Guy; Ross, Owen A; Salachas, Francois; Sidle, Katie; Smith, Bradley N; Soong, Bing-Wen; Sorarù, Gianni; Stevanin, Giovanni; Kabashi, Edor; Troakes, Claire; van Broeckhoven, Christine; Veldink, Jan H; van den Berg, Leonard H; Shaw, Christopher E; Powell, John F; Al-Chalabi, Ammar

    2017-03-01

    We investigated a CAG trinucleotide repeat expansion in the ATXN2 gene in amyotrophic lateral sclerosis (ALS). Two new case-control studies, a British dataset of 1474 ALS cases and 567 controls, and a Dutch dataset of 1328 ALS cases and 691 controls were analyzed. In addition, to increase power, we systematically searched PubMed for case-control studies published after 1 August 2010 that investigated the association between ATXN2 intermediate repeats and ALS. We conducted a meta-analysis of the new and existing studies for the relative risks of ATXN2 intermediate repeat alleles of between 24 and 34 CAG trinucleotide repeats and ALS. There was an overall increased risk of ALS for those carrying intermediate sized trinucleotide repeat alleles (odds ratio 3.06 [95% confidence interval 2.37-3.94]; p = 6 × 10 -18 ), with an exponential relationship between repeat length and ALS risk for alleles of 29-32 repeats (R 2  = 0.91, p = 0.0002). No relationship was seen for repeat length and age of onset or survival. In contrast to trinucleotide repeat diseases, intermediate ATXN2 trinucleotide repeat expansion in ALS does not predict age of onset but does predict disease risk. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  9. Botulinum toxin A injections and occupational therapy in children with unilateral spastic cerebral palsy: a randomized controlled trial.

    PubMed

    Lidman, Git; Nachemson, Ann; Peny-Dahlstrand, Marie; Himmelmann, Kate

    2015-08-01

    To investigate the effects of repeated botulinum toxin A (BoNT-A) injections combined with occupational therapy, including a splint, compared with occupational therapy alone on hand function in children with unilateral spastic cerebral palsy (USCP), in all International Classification of Functioning, Disability and Health (ICF) domains. This was a randomized controlled study, population-based and evaluator-blinded for primary outcome (October 2004 to September 2010). Twenty children (14 males; median age 3y 1mo) with USCP, recruited at a rehabilitation centre in Sweden, were assigned to one of two parallel groups using concealed allocation. In the course of one year, 10 children received occupational therapy, while 10 received repeated BoNT-A plus occupational therapy (BoNT-A/OT). Primary outcome (Assisting Hand Assessment [AHA]), and secondary outcome measures (range of movement [ROM], and Canadian Occupational Performance Measure), were measured at baseline, 3, 6, 9, and 12 months. AHA revealed a superior effect in the BoNT-A/OT group at 12 months: 6 out of 10 improved compared with 1 out of 10 in the occupational therapy group (p<0.03). A 95% Peskun exact confidence interval for the difference in proportions is given as 0.01 to 0.81. Secondary outcomes improved in both groups. Repeated BoNT-A/OT appeared superior to occupational therapy alone for bimanual performance in young children with USCP. Active ROM and goal performance improved in both groups. © 2015 Mac Keith Press.

  10. Measurement properties of continuous text reading performance tests.

    PubMed

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for reproducibility and repeatability studies. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  11. The Effects of Exercising in Different Natural Environments on Psycho-Physiological Outcomes in Post-Menopausal Women: A Simulation Study.

    PubMed

    White, Mathew P; Pahl, Sabine; Ashbullby, Katherine J; Burton, Francesca; Depledge, Michael H

    2015-09-23

    The current study examined potential psycho-physiological benefits from exercising in simulated natural environments among a sample of post-menopausal women using a laboratory based protocol. Participants cycled on a stationary exercise bike for 15 min while facing either a blank wall (Control) or while watching one of three videos: Urban (Grey), Countryside (Green), Coast (Blue). Blood pressure, heart rate and affective responses were measured pre-post. Heart rate, affect, perceived exertion and time perception were also measured at 5, 10 and 15 min during exercise. Experience evaluation was measured at the end. Replicating most earlier findings, affective, but not physiological, outcomes were more positive for exercise in the simulated Green and, for the first time, Blue environment, compared to Control. Moreover, only the simulated Blue environment was associated with shorter perceived exercise duration than Control and participants were most willing to repeat exercise in the Blue setting. The current research extended earlier work by exploring the effects of "blue exercise" and by using a demographic with relatively low average levels of physical activity. That this sample of postmenopausal women were most willing to repeat a bout of exercise in a simulated Blue environment may be important for physical activity promotion in this cohort.

  12. The Effects of Exercising in Different Natural Environments on Psycho-Physiological Outcomes in Post-Menopausal Women: A Simulation Study

    PubMed Central

    White, Mathew P.; Pahl, Sabine; Ashbullby, Katherine J.; Burton, Francesca; Depledge, Michael H.

    2015-01-01

    The current study examined potential psycho-physiological benefits from exercising in simulated natural environments among a sample of post-menopausal women using a laboratory based protocol. Participants cycled on a stationary exercise bike for 15 min while facing either a blank wall (Control) or while watching one of three videos: Urban (Grey), Countryside (Green), Coast (Blue). Blood pressure, heart rate and affective responses were measured pre-post. Heart rate, affect, perceived exertion and time perception were also measured at 5, 10 and 15 min during exercise. Experience evaluation was measured at the end. Replicating most earlier findings, affective, but not physiological, outcomes were more positive for exercise in the simulated Green and, for the first time, Blue environment, compared to Control. Moreover, only the simulated Blue environment was associated with shorter perceived exercise duration than Control and participants were most willing to repeat exercise in the Blue setting. The current research extended earlier work by exploring the effects of “blue exercise” and by using a demographic with relatively low average levels of physical activity. That this sample of postmenopausal women were most willing to repeat a bout of exercise in a simulated Blue environment may be important for physical activity promotion in this cohort. PMID:26404351

  13. Controls of repeating earthquakes' location from a- and b- values imaging

    NASA Astrophysics Data System (ADS)

    Chen, K. H.; Kawamura, M.

    2017-12-01

    The locations where creeping and locked fault areas abut have commonly found to be delineated by the foci of small repeating earthquakes (REs). REs not only represent the finer structure of high creep-rate location, they also function as fault slip-rate indicators. Knowledge of the expected location of REs therefore, is crucial for fault deformation monitoring and assessment of earthquake potential. However, a precise description of factors determining REs locations is lacking. To explore where earthquakes tend to recur, we statistically investigated repeating earthquake catalogs and background seismicity from different regions including six fault segments in California and Taiwan. We show that the location of repeating earthquakes can be mapped using the spatial distribution of the seismic a- and b-values obtained from the background seismicity. Molchan's error diagram statistically confirmed that repeating earthquakes occur within areas with high a-values (2.8-3.8) and high b-values (0.9-1.1) on both strike-slip and thrust fault segments. However, no significant association held true for fault segments with more complicated geometry or for wider areas with a complex fault network. The productivity of small earthquakes responsible for high a- and b-values may thus be the most important factor controlling the location of repeating earthquakes. We hypothesize that, given that the deformation conditions within a fault zone are suitable for a planar fault plane, the location of repeating earthquakes can be best described by a-value 3 and b-value 1. This feature of a- and b-values may be useful for foresee the location of REs for measuring creep rate at depth. Further investigation of REs-rich areas may allow testing of this hypothesis.

  14. The Pathogenic Role of Low Range Repeats in SCA17.

    PubMed

    Shin, Jung Hwan; Park, Hyeyoung; Ehm, Gwan Hee; Lee, Woong Woo; Yun, Ji Young; Kim, Young Eun; Lee, Jee-Young; Kim, Han-Joon; Kim, Jong-Min; Jeon, Beom Seok; Park, Sung-Sup

    2015-01-01

    SCA17 is an autosomal dominant cerebellar ataxia with expansion of the CAG/CAA trinucleotide repeats in the TATA-binding protein (TBP) gene. SCA17 can have various clinical presentations including parkinsonism, ataxia, chorea and dystonia. SCA17 is diagnosed by detecting the expanded CAG repeats in the TBP gene; however, in the literature, pathologic repeat numbers as low as 41 overlap with normal repeat numbers. The subjects in this study included patients with involuntary movement disorders such as cerebellar ataxia, parkinsonism, chorea and dystonia who visited Seoul National University Hospital between Jan. 2006 and Apr. 2014 and were screened for SCA17. Those who were diagnosed with other genetic diseases or nondegenerative diseases were excluded. DNA from healthy subjects who did not have a family history of parkinsonism, ataxia, psychiatric symptoms, chorea or dystonia served as the control. In total, 5242 chromosomes from 2099 patients and 522 normal controls were analyzed. The total number of patients included in the analysis was 2099 (parkinsonism, 1706; ataxia, 345; chorea, 37; and dystonia, 11). In the normal control, up to 44 repeats were found. In the 44 repeat group, there were 7 (0.3%) patients and 1 (0.2%) normal control. In 43 repeat group, there were 8 (0.4%) patients and 2 (0.4%) normal controls. In the 42 repeat group, there were 16 (0.8%) patients and 3 (0.6%) normal controls. In 41 repeat group, there were 48 (2.3%) patients and 8 (1.5%) normal controls. Considering the overlaps and non-significant differences in allelic frequencies between the patients and the normal controls with low-expansions, we could not determine a definitive cutoff value for the pathologic CAG repeat number of SCA17. Because the statistical analysis between the normal controls and patients with low range expansions failed to show any differences so far, we must consider that clinical cases with low range expansions could be idiopathic movement disorders showing coincidental CAG/CAA expansions. Thus, we need to reconsider the pathologic role of low range expansions (41-42). Long term follow up and comprehensive investigations using autopsy and imaging studies in patients and controls with low range expansions are necessary to determine the cutoff value for the pathologic CAG repeat number of SCA17.

  15. Status of a UAV SAR Designed for Repeat Pass Interferometry for Deformation Measurements

    NASA Technical Reports Server (NTRS)

    Hensley, Scott; Wheeler, Kevin; Hoffman, Jim; Miller, Tim; Lou, Yunling; Muellerschoen, Ron; Zebker, Howard; Madsen, Soren; Rosen, Paul

    2004-01-01

    Under the NASA ESTO sponsored Instrument Incubator Program we have designed a lightweight, reconfigurable polarimetric L-band SAR designed for repeat pass deformation measurements of rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes. This radar will be installed on an unmanned airborne vehicle (UAV) or a lightweight, high-altitude, and long endurance platform such as the Proteus. After a study of suitable available platforms we selected the Proteus for initial development and testing of the system. We want to control the repeat track capability of the aircraft to be within a 10 m tube to support the repeat deformation capability. We conducted tests with the Proteus using real-time GPS with sub-meter accuracy to see if pilots could fly the aircraft within the desired tube. Our results show that pilots are unable to fly the aircraft with the desired accuracy and therefore an augmented autopilot will be required to meet these objectives. Based on the Proteus flying altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and 16 km range swath. This radar will have an active electronic beam steering antenna to achieve Doppler centroid stability that is necessary for repeat-pass interferometry (RPI). This paper will present are design criteria, current design and expected science applications.

  16. Repeated Exposure to Conditioned Fear Stress Increases Anxiety and Delays Sleep Recovery Following Exposure to an Acute Traumatic Stressor

    PubMed Central

    Greenwood, Benjamin N.; Thompson, Robert S.; Opp, Mark R.; Fleshner, Monika

    2014-01-01

    Repeated stressor exposure can sensitize physiological responses to novel stressors and facilitate the development of stress-related psychiatric disorders including anxiety. Disruptions in diurnal rhythms of sleep–wake behavior accompany stress-related psychiatric disorders and could contribute to their development. Complex stressors that include fear-eliciting stimuli can be a component of repeated stress experienced by human beings, but whether exposure to repeated fear can prime the development of anxiety and sleep disturbances is unknown. In the current study, adult male F344 rats were exposed to either control conditions or repeated contextual fear conditioning for 22 days followed by exposure to no, mild (10), or severe (100) acute uncontrollable tail shock stress. Exposure to acute stress produced anxiety-like behavior as measured by a reduction in juvenile social exploration and exaggerated shock-elicited freezing in a novel context. Prior exposure to repeated fear enhanced anxiety-like behavior as measured by shock-elicited freezing, but did not alter social exploratory behavior. The potentiation of anxiety produced by prior repeated fear was temporary; exaggerated fear was present 1 day but not 4 days following acute stress. Interestingly, exposure to acute stress reduced rapid eye movement (REM) and non-REM (NREM) sleep during the hours immediately following acute stress. This initial reduction in sleep was followed by robust REM rebound and diurnal rhythm flattening of sleep/wake behavior. Prior repeated fear extended the acute stress-induced REM and NREM sleep loss, impaired REM rebound, and prolonged the flattening of the diurnal rhythm of NREM sleep following acute stressor exposure. These data suggest that impaired recovery of sleep/wake behavior following acute stress could contribute to the mechanisms by which a history of prior repeated stress increases vulnerability to subsequent novel stressors and stress-related disorders. PMID:25368585

  17. Control of the repeatability of high frequency multibeam echosounder backscatter by using natural reference areas

    NASA Astrophysics Data System (ADS)

    Roche, Marc; Degrendele, Koen; Vrignaud, Christophe; Loyer, Sophie; Le Bas, Tim; Augustin, Jean-Marie; Lurton, Xavier

    2018-06-01

    The increased use of backscatter measurements in time series for environmental monitoring necessitates the comparability of individual results. With the current lack of pre-calibrated multibeam echosounder systems for absolute backscatter measurement, a pragmatic solution is the use of natural reference areas for ensuring regular assessment of the backscatter measurement repeatability. This method mainly relies on the assumption of a sufficiently stable reference area regarding its backscatter signature. The aptitude of a natural area to provide a stable and uniform backscatter response must be carefully considered and demonstrated by a sufficiently long time-series of measurements. Furthermore, this approach requires a strict control of the acquisition and processing parameters. If all these conditions are met, stability check and relative calibration of a system are possible by comparison with the averaged backscatter values for the area. Based on a common multibeam echosounder and sampling campaign completed by available bathymetric and backscatter time series, the suitability as a backscatter reference area of three different candidates was evaluated. Two among them, Carré Renard and Kwinte, prove to be excellent choices, while the third one, Western Solent, lacks sufficient data over time, but remains a valuable candidate. The case studies and the available backscatter data on these areas prove the applicability of this method. The expansion of the number of commonly used reference areas and the growth of the number of multibeam echosounder controlled thereon could greatly contribute to the further development of quantitative applications based on multibeam echosounder backscatter measurements.

  18. Individual differences and repeatability in vocal production: stress-induced calling exposes a songbird's personality.

    PubMed

    Guillette, Lauren M; Sturdy, Christopher B

    2011-11-01

    Recent research in songbirds has demonstrated that male singing behavior varies systematically with personality traits such as exploration and risk taking. Here we examine whether the production of bird calls, in addition to bird songs, is repeatable and related to exploratory behavior, using the black-capped chickadee (Poecile atricapillus) as a model. We assessed the exploratory behavior of individual birds in a novel environment task. We then recorded the vocalizations and accompanying motor behavior of both male and female chickadees, over the course of several days, in two different contexts: a control condition with no playback and a stressful condition where chick-a-dee mobbing calls were played to individual birds. We found that several vocalizations and behaviors were repeatable within both a control and a stressful context, and across contexts. While there was no relationship between vocal output and exploratory behavior in the control context, production of alarm and chick-a-dee calls in the stressful condition was positively associated with exploratory behavior. These findings are important because they show that bird calls, in addition to bird song, are an aspect of personality, in that calls are consistent both within and across contexts, and covary with other personality measures (exploration).

  19. Individual differences and repeatability in vocal production: stress-induced calling exposes a songbird's personality

    NASA Astrophysics Data System (ADS)

    Guillette, Lauren M.; Sturdy, Christopher B.

    2011-11-01

    Recent research in songbirds has demonstrated that male singing behavior varies systematically with personality traits such as exploration and risk taking. Here we examine whether the production of bird calls, in addition to bird songs, is repeatable and related to exploratory behavior, using the black-capped chickadee ( Poecile atricapillus) as a model. We assessed the exploratory behavior of individual birds in a novel environment task. We then recorded the vocalizations and accompanying motor behavior of both male and female chickadees, over the course of several days, in two different contexts: a control condition with no playback and a stressful condition where chick-a-dee mobbing calls were played to individual birds. We found that several vocalizations and behaviors were repeatable within both a control and a stressful context, and across contexts. While there was no relationship between vocal output and exploratory behavior in the control context, production of alarm and chick-a-dee calls in the stressful condition was positively associated with exploratory behavior. These findings are important because they show that bird calls, in addition to bird song, are an aspect of personality, in that calls are consistent both within and across contexts, and covary with other personality measures (exploration).

  20. Management of geriatric incontinence in nursing homes.

    PubMed Central

    Schnelle, J F; Traughber, B; Morgan, D B; Embry, J E; Binion, A F; Coleman, A

    1983-01-01

    A behavioral management system designed to reduce urinary incontinence was evaluated in two nursing homes with a pretest-posttest control group design with repeated measures. The primary components of the system were prompting and contingent social approval/disapproval which required approximately 2.5 minutes per patient per hour to administer. The frequency of correct toileting for experimental subjects increased by approximately 45%. The experimental groups were significantly different from the control groups on both incontinence and correct toileting measures. The results are discussed in view of the management issues inherent in nursing home settings. PMID:6885672

  1. Effect of repeated sprints on postprandial endothelial function and triacylglycerol concentrations in adolescent boys.

    PubMed

    Sedgwick, Matthew J; Morris, John G; Nevill, Mary E; Barrett, Laura A

    2015-01-01

    This study investigated whether repeated, very short duration sprints influenced endothelial function (indicated by flow-mediated dilation) and triacylglycerol concentrations following the ingestion of high-fat meals in adolescent boys. Nine adolescent boys completed two, 2-day main trials (control and exercise), in a counter-balanced, cross-over design. Participants were inactive on day 1 of the control trial but completed 40 × 6 s maximal cycle sprints on day 1 of the exercise trial. On day 2, capillary blood samples were collected and flow-mediated dilation measured prior to, and following, ingestion of a high-fat breakfast and lunch. Fasting flow-mediated dilation and plasma triacylglycerol concentration were similar in the control and exercise trial (P > 0.05). In the control trial, flow-mediated dilation was reduced by 20% and 27% following the high-fat breakfast and lunch; following exercise these reductions were negated (main effect trial, P < 0.05; interaction effect trial × time, P < 0.05). The total area under the plasma triacylglycerol concentration versus time curve was 13% lower on day 2 in the exercise trial compared to the control trial (8.65 (0.97) vs. 9.92 (1.16) mmol · l(-1) · 6.5 h, P < 0.05). These results demonstrate that repeated 6 s maximal cycle sprints can have beneficial effects on postprandial endothelial function and triacylglycerol concentrations in adolescent boys.

  2. Comparison of optic area measurement using fundus photography and optical coherence tomography between optic nerve head drusen and control subjects.

    PubMed

    Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia

    2013-03-01

    To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  3. Telomeric repeat-containing RNA (TERRA) related to polycystic ovary syndrome (PCOS).

    PubMed

    Wang, Caiqin; Shen, Fengxian; Zhu, Yuning; Fang, Yuying; Lu, Shiming

    2017-04-01

    Telomeric repeat-containing RNA (TERRA) participates in the regulation of telomere length, and leucocyte telomere length (LTL) plays an important role in the pathophysiology of polycystic ovary syndrome (PCOS), but little is known about the role of TERRA in PCOS. To evaluate the role of TERRA and peripheral blood LTL in PCOS. Forty women with PCOS and 35 healthy women without PCOS were recruited. A prospective case-control study was performed. RNA fluorescence in situ hybridization (FISH) was used to detect TERRA expression in peripheral blood leucocyte. Quantitative PCR was used to measure TERRA expression and the mean LTL in the PCOS and control groups. We analysed the association between related clinical parameters and the age-adjusted ratio of the telomere repeat length (T/S ratio) or TERRA. Telomeric repeat-containing RNA was expressed in human peripheral blood leucocytes, and the signal was abolished after culture with RNase A. The age-adjusted LTLs were significantly longer in the PCOS group than in the control group (P < 0·01). The age-adjusted TERRA level was significantly lower in the PCOS group than in the control group (P < 0·01). Testosterone (TTE) was related positively to LTL and negatively to TERRA in the PCOS group (r = 0·532, P = 0·002; r = -0·477, P = 0·017). We found TERRA expression in human peripheral blood leucocytes, and LTLs were positively associated with PCOS. TERRA and testosterone play an important role in the LTL regulation in PCOS. © 2016 John Wiley & Sons Ltd.

  4. A comparison of three erosion control mulches on decommissioned forest road corridors in the northern Rocky Mountains, United States

    Treesearch

    R. B. Foltz

    2012-01-01

    This study tested the erosion mitigation effectiveness of agricultural straw and two wood-based mulches for four years on decommissioned forest roads. Plots were installed on the loosely consolidated, bare soil to measure sediment production, mulch cover, and plant regrowth. The experimental design was a repeated measures, randomized block on two soil types common in...

  5. The influence of cadence and shoes on patellofemoral joint kinetics in runners with patellofemoral pain.

    PubMed

    Bonacci, Jason; Hall, Michelle; Fox, Aaron; Saunders, Natalie; Shipsides, Tristan; Vicenzino, Bill

    2018-06-01

    To determine the effect of a combination of a minimalist shoe and increased cadence on measures of patellofemoral joint loading during running in individuals with patellofemoral pain. Within-participant repeated measures with four conditions presented in random order: (1) control shoe at preferred cadence; (2) control shoe with +10% cadence; (3) minimalist shoe at preferred cadence; (4) minimalist shoe with +10% cadence. Fifteen recreational runners with patellofemoral pain ran on an instrumented treadmill while three-dimensional motion capture data were acquired. Peak patellofemoral joint stress, joint reaction force, knee extensor moment and knee joint angle during the stance phase of running were calculated. One-way repeated measures ANOVA was used to compare the control condition (1) to the three experimental conditions (2-4). Running in a minimalist shoe at an increased cadence reduced patellofemoral stress and joint reaction force on average by approximately 29% (p<0.001) compared to the control condition. Running in a minimalist shoe at preferred cadence reduced patellofemoral joint stress by 15% and joint reaction force by 17% (p<0.001), compared to the control condition. Running in control shoes at an increased cadence reduced patellofemoral joint stress and joint reaction force by 16% and 19% (p<0.001), respectively, compared to the control condition. In individuals with patellofemoral pain, running in a minimalist shoe at an increased cadence had the greatest reduction in patellofemoral joint loading compared to a control shoe at preferred cadence. This may be an effective intervention to modulate biomechanical factors related to patellofemoral pain. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Measurement of cerebral perfusion volume and 99mTc-HMPAO uptake using SPECT in controls and patients with Alzheimer's disease.

    PubMed

    Fleming, J S; Kemp, P M; Bolt, L; Goatman, K A

    2002-11-01

    Methods for quantifying the changes in brain function observed in single photon emission computed tomography (SPECT) using hexamethylenepropylene amine oxime (HMPAO) for patients with Alzheimer's disease have the potential of improving the diagnostic accuracy of the procedure and its ability to monitor response to treatment. The absolute percentage uptake of HMPAO and the cerebral perfusion volume (CPV) of the brain were assessed using SPECT in 26 patients with mild to moderate Alzheimer's disease (AD) and 24 control subjects. A subset of 15 control subjects, which was age-matched to the AD patients, was selected to allow fair statistical comparison of parameters between groups. The percentage of brain volume with reduced perfusion (R) and a volume loss index (VLI), given by /CPV, were also calculated. Eight of the control subjects were studied on a second occasion after a mean period of 6 months. There was no significant difference in percentage uptake between controls and AD patients, the mean value being 5.8%. Cerebral perfusion volume in controls was found to depend on sex (mean value in males and females being 1327 ml and 1222 ml, respectively) and on age. The volume loss index corrected for age and sex provided good discrimination between controls and AD subjects giving a sensitivity and specificity of 81% and 96%, respectively. The repeatability coefficient, the 95% confidence limit for the difference between repeat measurements, on controls was 67 ml (5%). The measurement of cerebral perfusion volume and related indices may be of value in identifying patients with early Alzheimer's disease and in following their response to treatment.

  7. Repeated nicotine exposure enhances reward-related learning in the rat.

    PubMed

    Olausson, Peter; Jentsch, J David; Taylor, Jane R

    2003-07-01

    Repeated exposure to addictive drugs causes neuroadaptive changes in cortico-limbic-striatal circuits that may underlie alterations in incentive-motivational processes and reward-related learning. Such drug-induced alterations may be relevant to drug addiction because enhanced incentive motivation and increased control over behavior by drug-associated stimuli may contribute to aspects of compulsive drug-seeking and drug-taking behaviors. This study investigated the consequences of repeated nicotine treatment on the acquisition and performance of Pavlovian discriminative approach behavior, a measure of reward-related learning, in male rats. Water-restricted rats were trained to associate a compound conditioned stimulus (tone+light) with the availability of water (the unconditioned stimulus) in 15 consecutive daily sessions. In separate experiments, rats were repeatedly treated with nicotine (0.35 mg/kg, s.c.) either (1) prior to the onset of training, (2) after each daily training session was completed (ie postsession injections), or (3) received nicotine both before the onset of training as well as after each daily training session. In this study, all nicotine treatment schedules increased Pavlovian discriminative approach behavior and, thus, prior repeated exposure to nicotine, repeated postsession nicotine injections, or both, facilitated reward-related learning.

  8. Instruments speak global language

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nudo, L.

    1993-07-01

    If all goes as planned, companies that use instruments for measurement and control will get more complete, reliable and repeatable information about their processes with advanced digital devices that speak a global language. That language, in technical terms, is known as international fieldbus. But it's not much different from English's role as the international language of business. Companies that use a remote measurement device for environmental applications, such as pH control and fugitive emissions control, are candidates for fieldbus devices, which are much faster and measure more process variables than their counterpart analog devices. With the advent of a globalmore » fieldbus, users will see digital valves, solenoids and multivariable transmitters. Fieldbus technology redefines the roles of the control system and field devices. The control system still serves as a central clearinghouse, but field devices will handle more control and reporting functions and generate data that can be used for trending and preventive maintenance.« less

  9. Benefits of repeated individual dietary counselling in long-term weight control in women after delivery.

    PubMed

    Jaakkola, Johanna; Isolauri, Erika; Poussa, Tuija; Laitinen, Kirsi

    2015-10-01

    As pregnancy may trigger overweight in women, new means for its prevention are being sought. The aim here was to investigate the effect of individual dietary counselling during and after pregnancy on post-partum weight and waist circumference up to 4 years post-partum. A cohort of women (n = 256) were randomized to receive repeated individual dietary counselling by a nutritionist during and after pregnancy, or as controls not receiving dietary counselling, from the first trimester of pregnancy until 6 months after delivery. Counselling aimed to bring dietary intake into line with recommendations, with particular focus on the increase in the intake of unsaturated fatty acids instead of saturated. Pre-pregnancy weight was taken from welfare clinic records. Weight and waist circumference were measured at 4 years after delivery. The proportion of overweight women increased from 26% prior to pregnancy to 30% at 4 years after delivery among women receiving dietary counselling, as against considerably more, from 32% to 57%, among controls. The prevalence of central adiposity was 31% in women receiving dietary counselling, 64% in controls. Likewise, both the risk of overweight (odds ratio: 0.23, 0.08-0.63, P = 0.005) and central adiposity (odds ratio: 0.18, 0.06-0.52, P = 0.002) were lower in women receiving dietary counselling compared with controls. Repeated dietary counselling initiated in early pregnancy can be beneficial in long-term weight control after delivery. © 2014 John Wiley & Sons Ltd.

  10. Stress perception and (GT)n repeat polymorphism in haem oxygenase 1 promoter are both risk factors in development of eating disorders.

    PubMed

    Slachtová, L; Kaminská, D; Chvál, M; Králík, L; Martásek, P; Papežová, H

    2013-01-01

    Haem oxygenase 1 (HO-1) plays a pivotal role in metabolic stress protecting cells in dependence on reactive oxygen species. This study investigated a potential gene environment interaction between the (GT)n repeat HO1 polymorphism and the stress perception in patients with eating disorder and in controls. Stress perception and (GT)n polymorphism were measured in 127 patients with eating disorders and in 78 healthy controls using Stress and Coping Inventory and genotyping. Based on the inventory, overall, specific and weighted stress scores were defined. Clinical stress score was generated according to the patient's history and interviews. According to our hypothesis, 1) all stress scores describing subjective stress perception were significantly higher in patients compared to controls (P ≤ 0.001; P ≤ 0.002; P ≤ 0.001), 2) the L/L genotype of GT promoter repeats (L < 25 GT repeats, S < 25 GT repeats) in the patients was associated with higher overall (P ≤ 0.001), specific (P ≤ 0.010) and weighted stress score (P ≤ 0.005) compared to the L/S variant, and 3) Pearson's correlation of clinical versus objective stress scores showed not very tight relationship (0.198; 0.287; 0.224, respectively). We assume potential risk of the L allele of HO1 promoter polymorphism for the stress response and contribution of the subjective stress perception together with the L/L genotype to the development of eating disorder. Decreased HO1 expression in the presence of L/L genotype plus more intensive stress perception in the patients can lead to secondary stress, with increasing severity of the symptoms and aggravation of the disease.

  11. Intraspecific variation in flight metabolic rate in the bumblebee Bombus impatiens: repeatability and functional determinants in workers and drones.

    PubMed

    Darveau, Charles-A; Billardon, Fannie; Bélanger, Kasandra

    2014-02-15

    The evolution of flight energetics requires that phenotypes be variable, repeatable and heritable. We studied intraspecific variation in flight energetics in order to assess the repeatability of flight metabolic rate and wingbeat frequency, as well as the functional basis of phenotypic variation in workers and drones of the bumblebee species Bombus impatiens. We showed that flight metabolic rate and wingbeat frequency were highly repeatable in workers, even when controlling for body mass variation using residual analysis. We did not detect significant repeatability in drones, but a smaller range of variation might have prevented us from finding significant values in our sample. Based on our results and previous findings, we associated the high repeatability of flight phenotypes in workers to the functional links between body mass, thorax mass, wing size, wingbeat frequency and metabolic rate. Moreover, differences between workers and drones were as predicted from these functional associations, where drones had larger wings for their size, lower wingbeat frequency and lower flight metabolic rate. We also investigated thoracic muscle metabolic phenotypes by measuring the activity of carbohydrate metabolism enzymes, and we found positive correlations between mass-independent metabolic rate and the activity of all enzymes measured, but in workers only. When comparing workers and drones that differ in flight metabolic rate, only the activity of the enzymes hexokinase and trehalase showed the predicted differences. Overall, our study indicates that there should be correlated evolution among physiological phenotypes at multiple levels of organization and morphological traits associated with flight.

  12. Repeated mild traumatic brain injury produces neuroinflammation, anxiety-like behaviour and impaired spatial memory in mice.

    PubMed

    Broussard, John I; Acion, Laura; De Jesús-Cortés, Héctor; Yin, Terry; Britt, Jeremiah K; Salas, Ramiro; Costa-Mattioli, Mauro; Robertson, Claudia; Pieper, Andrew A; Arciniegas, David B; Jorge, Ricardo

    2018-01-01

    Repeated traumatic brain injuries (rmTBI) are frequently associated with debilitating neuropsychiatric conditions such as cognitive impairment, mood disorders, and post-traumatic stress disorder. We tested the hypothesis that repeated mild traumatic brain injury impairs spatial memory and enhances anxiety-like behaviour. We used a between groups design using single (smTBI) or repeated (rmTBI) controlled cranial closed skull impacts to mice, compared to a control group. We assessed the effects of smTBI and rmTBI using measures of motor performance (Rotarod Test [RT]), anxiety-like behaviour (Elevated Plus Maze [EPM] and Open Field [OF] tests), and spatial memory (Morris Water Maze [MWM]) within 12 days of the final injury. In separate groups of mice, astrocytosis and microglial activation were assessed 24 hours after the final injury using GFAP and IBA-1 immunohistochemistry. RmTBI impaired spatial memory in the MWM and increased anxiety-like behaviour in the EPM and OFT. In addition, rmTBI elevated GFAP and IBA-1 immunohistochemistry throughout the mouse brain. RmTBI produced astrocytosis and microglial activation, and elicited impaired spatial memory and anxiety-like behaviour. rmTBI produces acute cognitive and anxiety-like disturbances associated with inflammatory changes in brain regions involved in spatial memory and anxiety.

  13. Attenuation of muscle damage by preconditioning with muscle hyperthermia 1-day prior to eccentric exercise.

    PubMed

    Nosaka, K; Muthalib, M; Lavender, A; Laursen, P B

    2007-01-01

    This study investigated the hypothesis that muscle damage would be attenuated in muscles subjected to passive hyperthermia 1 day prior to exercise. Fifteen male students performed 24 maximal eccentric actions of the elbow flexors with one arm; the opposite arm performed the same exercise 2-4 weeks later. The elbow flexors of one arm received a microwave diathermy treatment that increased muscle temperature to over 40 degrees C, 16-20 h prior to the exercise. The contralateral arm acted as an untreated control. Maximal voluntary isometric contraction strength (MVC), range of motion (ROM), upper arm circumference, muscle soreness, plasma creatine kinase activity and myoglobin concentration were measured 1 day prior to exercise, immediately before and after exercise, and daily for 4 days following exercise. Changes in the criterion measures were compared between conditions (treatment vs. control) using a two-way repeated measures ANOVA with a significance level of P < 0.05. All measures changed significantly following exercise, but the treatment arm showed a significantly faster recovery of MVC, a smaller change in ROM, and less muscle soreness compared with the control arm. However, the protective effect conferred by the diathermy treatment was significantly less effective compared with that seen in the second bout performed 4-6 weeks after the initial bout by a subgroup of the subjects (n = 11) using the control arm. These results suggest that passive hyperthermia treatment 1 day prior to eccentric exercise-induced muscle damage has a prophylactic effect, but the effect is not as strong as the repeated bout effect.

  14. Effort-Based Decision-Making Paradigms for Clinical Trials in Schizophrenia: Part 1—Psychometric Characteristics of 5 Paradigms.

    PubMed

    Reddy, L Felice; Horan, William P; Barch, Deanna M; Buchanan, Robert W; Dunayevich, Eduardo; Gold, James M; Lyons, Naomi; Marder, Stephen R; Treadway, Michael T; Wynn, Jonathan K; Young, Jared W; Green, Michael F

    2015-09-01

    Impairments in willingness to exert effort contribute to the motivational deficits characteristic of the negative symptoms of schizophrenia. The current study evaluated the psychometric properties of 5 new or adapted paradigms to determine their suitability for use in clinical trials of schizophrenia. This study included 94 clinically stable participants with schizophrenia and 40 healthy controls. The effort-based decision-making battery was administered twice to the schizophrenia group (baseline, 4-week retest) and once to the control group. The 5 paradigms included 1 that assesses cognitive effort, 1 perceptual effort, and 3 that assess physical effort. Each paradigm was evaluated on (1) patient vs healthy control group differences, (2) test-retest reliability, (3) utility as a repeated measure (ie, practice effects), and (4) tolerability. The 5 paradigms showed varying psychometric strengths and weaknesses. The Effort Expenditure for Rewards Task showed the best reliability and utility as a repeated measure, while the Grip Effort Task had significant patient-control group differences, and superior tolerability and administration duration. The other paradigms showed weaker psychometric characteristics in their current forms. These findings highlight challenges in adapting effort and motivation paradigms for use in clinical trials. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center 2015.

  15. Demonstration of repeatability in a high-energy-density planar shear mixing layer experiment

    DOE PAGES

    Merritt, Elizabeth Catherine; Doss, Forrest William; Di Stefano, Carlos A.; ...

    2017-03-11

    On laser-driven platforms the assumption of experiment repeatability is particularly important due to a typically low data acquisition rate that doesn’t often allow for data redundancy. If the platform is repeatable, then measurements of the repeatable dynamics from multiple experiments can be treated as measurements of the same system. In high-energy-density hydrodynamic instability experiments the interface growth is assumed to be one of the repeatable aspects of the system. In this paper we demonstrate the repeatability of the instability growth in the counter-propagating shear experiment at the OMEGA laser facility, where the instability growth is characterized by the tracer layermore » thickness or mix-width evolution. Furthermore, in our previous experiment campaigns we have assumed the instability growth was repeatable enough to identify trends, but in this work we explicitly show that the mix-width measurements for nominally identical experiments are repeatable within the measurement error bars.« less

  16. Characterization and Early Detection of Balance Deficits in Fragile X Premutation Carriers With and Without Fragile X-Associated Tremor/Ataxia Syndrome (FXTAS).

    PubMed

    O'Keefe, Joan A; Robertson-Dick, Erin; Dunn, Emily J; Li, Yan; Deng, Youping; Fiutko, Amber N; Berry-Kravis, Elizabeth; Hall, Deborah A

    2015-12-01

    Fragile X-associated tremor/ataxia syndrome (FXTAS) results from a "premutation" size 55-200 CGG repeat expansion in the fragile X mental retardation 1 (FMR1) gene. Core motor features include cerebellar gait ataxia and kinetic tremor, resulting in progressive mobility disability. There are no published studies characterizing balance deficits in FMR1 premutation carriers with and without FXTAS using a battery of quantitative measures to test the sensory integration underlying postural control, automatic postural reflexes, and dynamic postural stability limits. Computerized dynamic posturography (CDP) and two performance-based balance measures were administered in 44 premutation carriers, 21 with FXTAS and 23 without FXTAS, and 42 healthy controls to compare balance and functional mobility between these groups. Relationships between FMR1 molecular variables, age, and sex and CDP scores were explored. FXTAS subjects demonstrated significantly lower scores on the sensory organization test (with greatest reductions in the vestibular control of balance), longer response latencies to balance perturbations, and reduced stability limits compared to controls. Premutation carriers without FXTAS also demonstrated significantly delayed response latencies and disrupted sensory weighting for balance control. Advancing age, male sex, increased CGG repeat size, and reduced X activation of the normal allele in premutation carrier women predicted balance dysfunction. These postural control deficits in carriers with and without FXTAS implicate dysfunctional cerebellar neural networks and may provide valuable outcome markers for tailored rehabilitative interventions. Our findings suggest that CDP may provide sensitive measures for early detection of postural control impairments in at-risk carriers and better characterize balance dysfunction and progression in FXTAS.

  17. Surface Wave Elastometry of the Cornea in Porcine and Human Donor Eyes

    PubMed Central

    Dupps, William J.; Netto, Marcelo V.; Herekar, Satish; Krueger, Ronald R.

    2007-01-01

    PURPOSE To introduce a nondestructive technique for characterization of corneal stiffness, determine measurement precision, and investigate comparative stiffness values along central, radial, and circumferential vectors in porcine corneas. The effects of epithelial debridement, relaxing incisions, and crosslink-mediated stiffening on surface wave velocity are also studied. METHODS A handheld prototype system was used to measure ultrasound surface wave propagation time between two fixed-distance transducers along a ten-position map. Repeatability was assessed with replicate measurements in 6 porcine corneas. In 12 porcine globes with controlled intraocular pressure (IOP), serial measurements were performed before and after epithelial removal, then after 250- and 750-μm-deep relaxing incisions. In human globes with constant intravitreal pressure, central wave velocity and transcorneal IOP measurements were compared before and after collagen cross-linking. RESULTS Measurement repeatability across all regions was between 2.2% and 8.1%. Epithelial removal resulted in increases in measured stiffness in 67% of eyes, but statistical power was insufficient to detect a systematic change. Wave velocity across a central incision decreased significantly after 250-μm keratotomy (P<.001), but did not undergo a significant further decrease with deeper keratotomy. Meridional stiffness changes consistent with coupling effects were detected after keratotomy. Surface wave velocity and transcorneal IOP measurements increased markedly after collagen cross-linking despite maintenance of a constant IOP. CONCLUSIONS Handheld corneal elastometry provides a repeatable measure of regional stiffness changes after relaxing incisions and collagen cross-linking in in vitro experiments. Surface wave elastometry allows focal assessment of corneal biomechanical properties that are relevant in refractive surgery, ectatic disease, and glaucoma. PMID:17269246

  18. An Intervention to Improve Motivation for Homework

    ERIC Educational Resources Information Center

    Akioka, Elisabeth; Gilmore, Linda

    2013-01-01

    A repeated measures design, with randomly assigned intervention and control groups and multiple sources of information on each participant, was used to examine whether changing the method of delivery of a school's homework program in order to better meet the students' needs for autonomy, relatedness and competence would lead to more positive…

  19. Justification for the Carzo-Yanouzas Experiment on Flat and Tall Structures

    ERIC Educational Resources Information Center

    Carzo, Rocco, Jr.; Yanouzas, John N.

    1970-01-01

    Replies to Hummon's criticism (EA 500 730) of experiment, justifying use of split-plot repeated measures design, and tests for homogeneity support the use of this design. Variables considered to be not under control are explained as attributes of structure or as variables having inconsequential effects. (Author/KJ)

  20. An examination of the origin and evolution of additional tandem repeats in the mitochondrial DNA control region of Japanese sika deer (Cervus Nippon).

    PubMed

    Ba, Hengxing; Wu, Lang; Liu, Zongyue; Li, Chunyi

    2016-01-01

    Tandem repeat units are only detected in the left domain of the mitochondrial DNA control region in sika deer. Previous studies showed that Japanese sika deer have more tandem repeat units than its cousins from the Asian continent and Taiwan, which often have only three repeat units. To determine the origin and evolution of these additional repeat units in Japanese sika deer, we obtained the sequence of repeat units from an expanded dataset of the control region from all sika deer lineages. The functional constraint is inferred to act on the first repeat unit because this repeat has the least sequence divergence in comparison to the other units. Based on slipped-strand mispairing mechanisms, the illegitimate elongation model could account for the addition or deletion of these additional repeat units in the Japanese sika deer population. We also report that these additional repeat units could be occurring in the internal positions of tandem repeat regions, possibly via coupling with a homogenization mechanism within and among these lineages. Moreover, the increased number of repeat units in the Japanese sika deer population could reflect a balance between mutation and selection, as well as genetic drift.

  1. The CAG repeat polymorphism in the Androgen receptor gene modifies the risk for hypospadias in Caucasians

    PubMed Central

    2012-01-01

    Background Hypospadias is a birth defect of the urethra in males, and a milder form of 46,XY disorder of sexual development (DSD). The disease is characterized by a ventrally placed urinary opening due to a premature fetal arrest of the urethra development. Moreover, the Androgen receptor (AR) gene has an essential role in the hormone-dependent stage of sexual development. In addition, longer AR polyglutamine repeat lengths encoded by CAG repeats are associated with lower transcriptional activity in vitro. In the present study, we aimed at investigating the role of the CAG repeat length in the AR gene in hypospadias cases as compared to the controls. Our study included 211 hypospadias and 208 controls of Caucasian origin. Methods We amplified the CAG repeat region with PCR, and calculated the difference in the mean CAG repeat length between the hypospadias and control group using the T-test for independent groups. Results We detected a significant increase of the CAG repeat length in the hypospadias cases when compared to the controls (contrast estimate: 2.29, 95% Confidence Interval (1.73-2.84); p-value: 0.001). In addition, the odds ratios between the hypospadias and controls revealed that the hypospadias cases are two to 3 times as likely to have longer CAG repeats than a shorter length for each repeat length investigated. Conclusions We have investigated the largest number of hypospadias cases with regards to the CAG repeat length, and we provide evidence that a higher number of the CAG repeat sequence in the AR gene have a clear effect on the risk of hypospadias in Caucasians. PMID:23167717

  2. Repeated onabotulinumtoxin-a injections provide better results than single injection in treatment of painful bladder syndrome.

    PubMed

    Kuo, Hann-Chorng

    2013-01-01

    Onabotulinumtoxin-A (BoNT-A) is effective for the treatment of interstitial cystitis/painful bladder syndrome (IC/PBS). However, long-term follow-up does not show successful outcome after a single injection. To evaluate the efficacy and safety of repeated intravesical BoNT-A injections for treatment of IC/PBS and compare the success rates among patient groups receiving different injection numbers. Prospective interventional study. Tertiary medical center. Intravesical injection of 100 U of BoNT-A was performed in 81 patients every 6 months for up to 4 times or until patients' symptoms significantly improved. Patients who received a single injection served as active controls. Measured parameters included O'Leary-Sant symptom indexes (ICSI) and problem indexes (ICPI), visual analogue score (VAS) for pain, voiding diary variables, urodynamic parameters, maximal bladder capacity under anesthesia, glomerulation grade, and global response assessment. Multiple measurements and Kaplan-Meier analysis were used for comparison of consecutive data and success rates among groups. Among 81 patients, 20 received single injections, 19 received 2 injections, 12 received 3 injections, and 30 received 4 injections. The mean (± standard deviation) of ICSI, ICPI, total scores, VAS, functional bladder capacity, and daytime frequency all showed significant improvement after repeated BoNT-A treatment with different injections. Significantly better success rates were noted in patients who received 4 repeated injections (P = 0.0242) and 3 injections (P = 0.050), compared to those who received a single injection. However, there was no significant difference of long-term success rates among patients who received 2, 3, and 4 injections. Lack of placebo control group is the main limitation. Repeated intravesical BoNT-A injections were safe and effective for pain relief and they increased bladder capacity and provided a better long-term success rate than a single injection did for treatment of IC/PBS.

  3. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    PubMed

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  4. A menu of self-administered microcomputer-based neurotoxicology tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Wilkes, Robert L.; Kuntz, Lois-Ann; Baltzley, Dennis R.

    1988-01-01

    This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

  5. Precision and repeatability of the Optotrak 3020 motion measurement system.

    PubMed

    States, R A; Pappas, E

    2006-01-01

    Several motion analysis systems are used by researchers to quantify human motion and to perform accurate surgical procedures. The Optotrak 3020 is one of these systems and despite its widespread use there is not any published information on its precision and repeatability. We used a repeated measures design study to evaluate the precision and repeatability of the Optotrak 3020 by measuring distance and angle in three sessions, four distances and three conditions (motion, static vertical, and static tilted). Precision and repeatability were found to be excellent for both angle and distance although they decreased with increasing distance from the sensors and with tilt from the plane of the sensors. Motion did not have a significant effect on the precision of the measurements. In conclusion, the measurement error of the Optotrak is minimal. Further studies are needed to evaluate its precision and repeatability under human motion conditions.

  6. A comparison of recordings of sentences and spontaneous speech: perceptual and acoustic measures in preschool children's voices.

    PubMed

    McAllister, Anita; Brandt, Signe Kofoed

    2012-09-01

    A well-controlled recording in a studio is fundamental in most voice rehabilitation. However, this laboratory like recording method has been questioned because voice use in a natural environment may be quite different. In children's natural environment, high background noise levels are common and are an important factor contributing to voice problems. The primary noise source in day-care centers is the children themselves. The aim of the present study was to compare perceptual evaluations of voice quality and acoustic measures from a controlled recording with recordings of spontaneous speech in children's natural environment in a day-care setting. Eleven 5-year-old children were recorded three times during a day at the day care. The controlled speech material consisted of repeated sentences. Matching sentences were selected from the spontaneous speech. All sentences were repeated three times. Recordings were randomized and analyzed acoustically and perceptually. Statistic analyses showed that fundamental frequency was significantly higher in spontaneous speech (P<0.01) as was hyperfunction (P<0.001). The only characteristic the controlled sentences shared with spontaneous speech was degree of hoarseness (Spearman's rho=0.564). When data for boys and girls were analyzed separately, a correlation was found for the parameter breathiness (rho=0.551) for boys, and for girls the correlation for hoarseness remained (rho=0.752). Regarding acoustic data, none of the measures correlated across recording conditions for the whole group. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  7. A passive heat maintenance strategy implemented during a simulated half-time improves lower body power output and repeated sprint ability in professional Rugby Union players.

    PubMed

    Russell, Mark; West, Daniel J; Briggs, Marc A; Bracken, Richard M; Cook, Christian J; Giroud, Thibault; Gill, Nicholas; Kilduff, Liam P

    2015-01-01

    Reduced physical performance has been observed following the half-time period in team sports players, likely due to a decrease in muscle temperature during this period. We examined the effects of a passive heat maintenance strategy employed between successive exercise bouts on core temperature (Tcore) and subsequent exercise performance. Eighteen professional Rugby Union players completed this randomised and counter-balanced study. After a standardised warm-up (WU) and 15 min of rest, players completed a repeated sprint test (RSSA 1) and countermovement jumps (CMJ). Thereafter, in normal training attire (Control) or a survival jacket (Passive), players rested for a further 15 min (simulating a typical half-time) before performing a second RSSA (RSSA 2) and CMJ's. Measurements of Tcore were taken at baseline, post-WU, pre-RSSA 1, post-RSSA 1 and pre-RSSA 2. Peak power output (PPO) and repeated sprint ability was assessed before and after the simulated half-time. Similar Tcore responses were observed between conditions at baseline (Control: 37.06±0.05°C; Passive: 37.03±0.05°C) and for all other Tcore measurements taken before half-time. After the simulated half-time, the decline in Tcore was lower (-0.74±0.08% vs. -1.54±0.06%, p<0.001) and PPO was higher (5610±105 W vs. 5440±105 W, p<0.001) in the Passive versus Control condition. The decline in PPO over half-time was related to the decline in Tcore (r = 0.632, p = 0.005). In RSSA 2, best, mean and total sprint times were 1.39±0.17% (p<0.001), 0.55±0.06% (p<0.001) and 0.55±0.06% (p<0.001) faster for Passive versus Control. Passive heat maintenance reduced declines in Tcore that were observed during a simulated half-time period and improved subsequent PPO and repeated sprint ability in professional Rugby Union players.

  8. Repeatability, Reproducibility, Separative Power and Subjectivity of Different Fish Morphometric Analysis Methods

    PubMed Central

    Takács, Péter

    2016-01-01

    We compared the repeatability, reproducibility (intra- and inter-measurer similarity), separative power and subjectivity (measurer effect on results) of four morphometric methods frequently used in ichthyological research, the “traditional” caliper-based (TRA) and truss-network (TRU) distance methods and two geometric methods that compare landmark coordinates on the body (GMB) and scales (GMS). In each case, measurements were performed three times by three measurers on the same specimen of three common cyprinid species (roach Rutilus rutilus (Linnaeus, 1758), bleak Alburnus alburnus (Linnaeus, 1758) and Prussian carp Carassius gibelio (Bloch, 1782)) collected from three closely-situated sites in the Lake Balaton catchment (Hungary) in 2014. TRA measurements were made on conserved specimens using a digital caliper, while TRU, GMB and GMS measurements were undertaken on digital images of the bodies and scales. In most cases, intra-measurer repeatability was similar. While all four methods were able to differentiate the source populations, significant differences were observed in their repeatability, reproducibility and subjectivity. GMB displayed highest overall repeatability and reproducibility and was least burdened by measurer effect. While GMS showed similar repeatability to GMB when fish scales had a characteristic shape, it showed significantly lower reproducability (compared with its repeatability) for each species than the other methods. TRU showed similar repeatability as the GMS. TRA was the least applicable method as measurements were obtained from the fish itself, resulting in poor repeatability and reproducibility. Although all four methods showed some degree of subjectivity, TRA was the only method where population-level detachment was entirely overwritten by measurer effect. Based on these results, we recommend a) avoidance of aggregating different measurer’s datasets when using TRA and GMS methods; and b) use of image-based methods for morphometric surveys. Automation of the morphometric workflow would also reduce any measurer effect and eliminate measurement and data-input errors. PMID:27327896

  9. Hippocampal MR volumetry

    NASA Astrophysics Data System (ADS)

    Haller, John W.; Botteron, K.; Brunsden, Barry S.; Sheline, Yvette I.; Walkup, Ronald K.; Black, Kevin J.; Gado, Mokhtar; Vannier, Michael W.

    1994-09-01

    Goal: To estimate hippocampal volumes from in vivo 3D magnetic resonance (MR) brain images and determine inter-rater and intra- rater repeatability. Objective: The precision and repeatability of hippocampal volume estimates using stereologic measurement methods is sought. Design: Five normal control and five schizophrenic subjects were MR scanned using a MPRAGE protocol. Fixed grid stereologic methods were used to estimate hippocampal volumes on a graphics workstation. The images were preprocessed using histogram analysis to standardize 3D MR image scaling from 16 to 8 bits and image volumes were interpolated to 0.5 mm3 isotropic voxels. The following variables were constant for the repeated stereologic measures: grid size, inter-slice distance (1.5 mm), voxel dimensions (0.5 mm3), number of hippocampi measured (10), total number of measurements per rater (40), and number of raters (5). Two grid sizes were tested to determine the coefficient of error associated with the number of sampled 'hits' (approximately 140 and 280) on the hippocampus. Starting slice and grid position were randomly varied to assure unbiased volume estimates. Raters were blind to subject identity, diagnosis, and side of the brain from which the image volumes were extracted and the order of subject presentation was randomized for each of the raters. Inter- and intra-rater intraclass correlation coefficients (ICC) were determined. Results: The data indicate excellent repeatability of fixed grid stereologic hippocampal volume measures when using an inter-slice distance of 1.5 mm and a 6.25 mm2 grid (inter-rater ICCs equals 0.86 - 0.97, intra- rater ICCs equals 0.85 - 0.97). One major advantage of the current study was the use of 3D MR data which significantly improved visualization of hippocampal boundaries by providing the ability to access simultaneous orthogonal views while counting stereological marks within the hippocampus. Conclusion: Stereological estimates of 3D volumes from 2D MR sections provide an inexpensive, unbiased and efficient way of determining brain structural volumes. The high precision and repeatability demonstrated with stereological MR volumetry suggest that these methods may be efficiently used to measure small volume reductions associated with schizophrenia and other brain disorders.

  10. Effect of regional and systemic fluorinated pyrimidine chemotherapy on quality of life in colorectal liver metastasis patients.

    PubMed

    Earlam, S; Glover, C; Davies, M; Fordy, C; Allen-Mersh, T G

    1997-05-01

    Since systemic and regional (HAI) fluorinated pyrimidine chemotherapies offer similar survival benefit in treatment of colorectal liver metastases (CLM), we sought to identify their impact on quality of life (QoL), which might be a useful indicator of treatment preference. We compared QoL in 135 CLM patients managed by symptom control (n = 49 patients), systemic fluorouracil (5FU)/folinic acid (n = 35), or hepatic arterial floxuridine (FUDR) (n = 51). Full blood count and liver function tests, World Health Organization (WHO) toxicity criteria, and QoL (Rotterdam Symptom Checklist [RSC], the Sickness Impact Profile [SIP], and the Hospital Anxiety and Depression scale [HAD]) were measured monthly in all patients. The HAD anxiety score was significantly increased in symptom control compared with chemotherapy patients 1 month after randomization. There was a significant increase in RSC physical score (repeated measures, P = .05), and in scores for sore mouth (P < .01), dry mouth (P < .01), and tingling hands and feet (P < .01) in systemic chemotherapy compared with symptom control patients. Significant QoL differences (repeated measures and Mann-Whitney U [MWU]) between HAI and symptom control patients were not detected. Systemic chemotherapy patients lived for significantly longer (log-rank test, P < or = .0001) with abnormal HAD anxiety, RSC psychosocial, or RSC sore mouth scores compared with HAI patients, but there were no overall survival differences. Randomization to symptom control only was associated with increased anxiety. QoL with systemic chemotherapy was impaired by side effects. HAI was associated with similar survival to systemic chemotherapy but with better sustained QoL.

  11. Near common-path optical fiber interferometer for potentially fast on-line microscale-nanoscale surface measurement

    NASA Astrophysics Data System (ADS)

    Jiang, Xiangqian; Wang, Kaiwei; Martin, Haydn

    2006-12-01

    We introduce a new surface measurement method for potential online application. Compared with our previous research, the new design is a significant improvement. It also features high stability because it uses a near common-path configuration. The method should be of great benefit to advanced manufacturing, especially for quality and process control in ultraprecision manufacturing and on the production line. Proof-of-concept experiments have been successfully conducted by measuring the system repeatability and the displacements of a mirror surface.

  12. Use of a crop and job specific exposure matrix for retrospective assessment of long-term exposure in studies of chronic neurotoxic effects of agrichemicals

    PubMed Central

    London, L.; Myers, J. E.

    1998-01-01

    RATIONALE: Job exposure matrices (JEMs) are widely used in occupational epidemiology, particularly when biological or environmental monitoring data are scanty. However, as with most exposure estimates, JEMs may be vulnerable to misclassification. OBJECTIVES: To estimate the long term exposure of farm workers based on a JEM developed for use in a study of the neurotoxic effects of organophosphates and to evaluate the repeatability and validity of the JEM. METHODS: A JEM was constructed with secondary data from industry and expert opinion of the estimate of agrichemical exposure within every possible job activity in the JEM to weight job days for exposure to organophosphates. Cumulative lifetime and average intensity exposure of organophosphate exposure were calculated for 163 pesticide applicators and 84 controls. Repeat questionnaires were given to 29 participants three months later to test repeatability of measurements. The ability of JEM based exposure to predict a known marker of organophosphate exposure was used to validate the JEM. RESULTS: Cumulative lifetime exposure as measured in kg organophosphate exposure, was significantly associated with erythrocyte cholinesterase concentrations (partial r2 = 5%; p < 0.01), controlled for a range of confounders. Repeatability in a subsample of 29 workers of the estimates of cumulative (Pearson's r = 0.67; 95% confidence interval (95% CI) 0.41 to 0.83), and average lifetime intensity of exposure (Pearson's r = 0.60 95% CI 0.31 to 0.79) was adequate. CONCLUSION: The JEM seems promising for farming settings, particularly in developing countries where data on chemical application and biological monitoring are unavailable.   PMID:9624271

  13. A contralateral repeated bout effect attenuates induction of NF-κB DNA binding following eccentric exercise.

    PubMed

    Xin, Ling; Hyldahl, Robert D; Chipkin, Stuart R; Clarkson, Priscilla M

    2014-06-01

    We investigated the existence of contralateral repeated bout effect and tested if the attenuation of nuclear factor-kappa B (NF-κB; an important regulator of muscle inflammation) induction following eccentric exercise is a potential mechanism. Thirty-one healthy men performed two bouts of knee extension eccentric exercise, initially with one leg and then with the opposite leg 4 wk later. Vastus lateralis muscle biopsies of both exercised and control legs were taken 3 h postexercise. Knee extension isometric and isokinetic strength (60°/sec and 180°/sec) were measured at baseline, pre-exercise, immediately postexercise, and 1/day for 5 days postexercise. Serum creatine kinase (CK) activity and muscle soreness were assessed at baseline and 1/day for 5 days postexercise. NF-κB (p65) DNA-binding activity was measured in the muscle biopsies. Isometric strength loss was lower in bout 2 than in bout 1 at 24, 72, and 96 h postexercise (P < 0.05). Isokinetic strength (60°/s and 180°/s) was reduced less in bout 2 than in bout 1 at 72 h postexercise (P < 0.01). There were no significant differences between bouts for postexercise CK activity or muscle soreness. p65 DNA-binding activity was increased following eccentric exercise (compared with the control leg) in bout 1 (122.9% ± 2.6%; P < 0.001) and bout 2 (109.1% ± 3.0%; P < 0.05). Compared with bout 1, the increase in NF-κB DNA-binding activity postexercise was attenuated after bout 2 (P = 0.0008). Repeated eccentric exercise results in a contralateral repeated bout effect, which could be due to the attenuated increase in NF-κB activity postexercise. Copyright © 2014 the American Physiological Society.

  14. Optimization of Control Points Number at Coordinate Measurements based on the Monte-Carlo Method

    NASA Astrophysics Data System (ADS)

    Korolev, A. A.; Kochetkov, A. V.; Zakharov, O. V.

    2018-01-01

    Improving the quality of products causes an increase in the requirements for the accuracy of the dimensions and shape of the surfaces of the workpieces. This, in turn, raises the requirements for accuracy and productivity of measuring of the workpieces. The use of coordinate measuring machines is currently the most effective measuring tool for solving similar problems. The article proposes a method for optimizing the number of control points using Monte Carlo simulation. Based on the measurement of a small sample from batches of workpieces, statistical modeling is performed, which allows one to obtain interval estimates of the measurement error. This approach is demonstrated by examples of applications for flatness, cylindricity and sphericity. Four options of uniform and uneven arrangement of control points are considered and their comparison is given. It is revealed that when the number of control points decreases, the arithmetic mean decreases, the standard deviation of the measurement error increases and the probability of the measurement α-error increases. In general, it has been established that it is possible to repeatedly reduce the number of control points while maintaining the required measurement accuracy.

  15. Using Hypnosis to Enhance Learning Second Language Vocabulary.

    PubMed

    Çetin, Yakup; Çimen, O Arda; Yetkiner, Zeynep Ebrar

    2016-04-01

    In this article, we measure the effects of hypnosis and suggestions for learning second language vocabulary. Participants (N = 70) were randomly assigned to a hypnosis or a control group. They were pre-tested, and then presented 21 Spanish words, post-tested immediately and 1 week later. The data were analyzed using repeated measures analysis of variance with group (experimental versus control) as the between-subjects factor, and time as the within-subjects factor. The experimental group performed significantly better in both tests. Our results indicate that hypnosis is beneficial for second language vocabulary learning and retrieval.

  16. Flight investigation of cabin noise control treatments for a light turboprop aircraft

    NASA Technical Reports Server (NTRS)

    Wilby, J. F.; Oneal, R. L.; Mixson, J. S.

    1985-01-01

    The in-flight evaluation of noise control treatments for a light, twin-engined turboprop aircraft presents several problems associated with data analysis and interpretation. These problems include data repeatability, propeller synchronization, spatial distributions of the exterior pressure field and acoustic treatment, and the presence of flanking paths. They are discussed here with regard to a specific aeroplane configuration. Measurements were made in an untreated cabin and in a cabin fitted with an experimental sidewall treatment. Results are presented in terms of the insertion loss provided by the treatment and comparison made with predictions based on laboratory measurements.

  17. Icing research tunnel rotating bar calibration measurement system

    NASA Technical Reports Server (NTRS)

    Gibson, Theresa L.; Dearmon, John M.

    1993-01-01

    In order to measure icing patterns across a test section of the Icing Research Tunnel, an automated rotating bar measurement system was developed at the NASA Lewis Research Center. In comparison with the previously used manual measurement system, this system provides a number of improvements: increased accuracy and repeatability, increased number of data points, reduced tunnel operating time, and improved documentation. The automated system uses a linear variable differential transformer (LVDT) to measure ice accretion. This instrument is driven along the bar by means of an intelligent stepper motor which also controls data recording. This paper describes the rotating bar calibration measurement system.

  18. Fair Play for Kids: effects on the moral development of children in physical education.

    PubMed

    Gibbons, S L; Ebbeck, V; Weiss, M R

    1995-09-01

    Commitment to the principles of sportspersonship is an acknowledged goal for school physical education. However, few programs have been implemented to investigate moral development changes in physical activity settings. A field experiment was designed to examine the effect of participation in educational activities selected from Fair Play for Kids (1990) on the moral judgment, reason, intention, and prosocial behavior of children (N = 452) in the 4th through 6th grades. Six intact classrooms at each grade level (N = 18) were randomly assigned to the following groups: (a) control, (b) Fair Play for Kids curriculum during physical education only, or (c) Fair Play for Kids curriculum during all school subjects. Experimental protocol extended for 7 months of an academic year, and moral development indicators were assessed prior to and following the intervention. Using class as the unit of analysis, 3 x 2 (Group x Time) repeated measures analyses of variance revealed that both treatment groups were significantly higher than the control group at posttest for moral judgment, reason, and intention scores. For students within classes, repeated measures analyses showed that treatment group participants had significantly higher posttest scores on all 4 measures as compared to students in the control group. Results provide initial validation of the Fair Play For Kids curriculum for effecting change in the moral development of elementary school students.

  19. Head eye co-ordination and gaze stability in subjects with persistent whiplash associated disorders.

    PubMed

    Treleaven, Julia; Jull, Gwendolen; Grip, Helena

    2011-06-01

    Symptoms of dizziness, unsteadiness and visual disturbances are frequent complaints in persons with persistent whiplash associated disorders. This study investigated eye, head co-ordination and gaze stability in subjects with persistent whiplash (n = 20) and asymptomatic controls (n = 20). Wireless motion sensors and electro-oculography were used to measure: head rotation during unconstrained head movement, head rotation during gaze stability and sequential head and eye movements. Ten control subjects participated in a repeatability study (two occasions one week apart). Between-day repeatability was acceptable (ICC > 0.6) for most measures. The whiplash group had significantly less maximal eye angle to the left, range of head movement during the gaze stability task and decreased velocity of head movement in head eye co-ordination and gaze stability tasks compared to the control group (p < 0.01). There were significant correlations (r > 0.55) between both unrestrained neck movement and neck pain and head movement and velocity in the whiplash group. Deficits in gaze stability and head eye co-ordination may be related to disturbed reflex activity associated with decreased head range of motion and/or neck pain. Further research is required to explore the mechanisms behind these deficits, the nature of changes over time and the tests' ability to measure change in response to rehabilitation. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  20. Central gene expression changes associated with enhanced neuroendocrine and autonomic response habituation to repeated noise stress after voluntary wheel running in rats

    PubMed Central

    Sasse, Sarah K.; Nyhuis, Tara J.; Masini, Cher V.; Day, Heidi E. W.; Campeau, Serge

    2013-01-01

    Accumulating evidence indicates that regular physical exercise benefits health in part by counteracting some of the negative physiological impacts of stress. While some studies identified reductions in some measures of acute stress responses with prior exercise, limited data were available concerning effects on cardiovascular function, and reported effects on hypothalamic-pituitary-adrenocortical (HPA) axis responses were largely inconsistent. Given that exposure to repeated or prolonged stress is strongly implicated in the precipitation and exacerbation of illness, we proposed the novel hypothesis that physical exercise might facilitate adaptation to repeated stress, and subsequently demonstrated significant enhancement of both HPA axis (glucocorticoid) and cardiovascular (tachycardia) response habituation to repeated noise stress in rats with long-term access to running wheels compared to sedentary controls. Stress habituation has been attributed to modifications of brain circuits, but the specific sites of adaptation and the molecular changes driving its expression remain unclear. Here, in situ hybridization histochemistry was used to examine regulation of select stress-associated signaling systems in brain regions representing likely candidates to underlie exercise-enhanced stress habituation. Analyzed brains were collected from active (6 weeks of wheel running) and sedentary rats following control, acute, or repeated noise exposures that induced a significantly faster rate of glucocorticoid response habituation in active animals but preserved acute noise responsiveness. Nearly identical experimental manipulations also induce a faster rate of cardiovascular response habituation in exercised, repeatedly stressed rats. The observed regulation of the corticotropin-releasing factor and brain-derived neurotrophic factor systems across several brain regions suggests widespread effects of voluntary exercise on central functions and related adaptations to stress across multiple response modalities. PMID:24324441

  1. Risk Propensity, Risk Perception, and Sensation Seeking in US Army Soldiers: A Preliminary Study of a Risk Assessment Task Battery

    DTIC Science & Technology

    2010-10-01

    Specifically, if deployment is retrospectively perceived as very risky or dangerous , then the perceived risk of negative consequences of risky behaviors...preference for various types of risky activities. There are five sub-scales of the EVAR; self-control, danger seeking, energy, impulsiveness, and...the total and five sub-scale (self-control, danger seeking, energy, impulsiveness, and invincibility) scores were calculated. A repeated measures

  2. Compelling Evidence that Exposure Therapy for PTSD Normalizes Brain Function.

    PubMed

    Roy, Michael J; Costanzo, Michelle E; Blair, James R; Rizzo, Albert A

    2014-01-01

    Functional magnetic resonance imaging (fMRI) is helping us better understand the neurologic pathways involved in posttraumatic stress disorder (PTSD). We previously reported that military service members with PTSD after deployment to Iraq or Afghanistan demonstrated significant improvement, or normalization, in the fMRI-measured activation of the amygdala, prefrontal cortex and anterior cingulate gyrus following exposure therapy for PTSD. However, our original study design did not include repeat scans of control participants, rendering it difficult to discern how much of the observed normalization in brain activity is attributable to treatment, rather than merely a practice effect. Using the same Affective Stroop task paradigm, we now report on a larger sample of PTSD-positive combat veterans that we treated with exposure therapy, as well as a combat-exposed control group of service members who completed repeat scans at 3-4 month intervals. Findings from the treatment group are similar to our prior report. Combat controls showed no significant change on repeat scanning, indicating that the observed differences in the intervention group were in fact due to treatment. We continue to scan additional study participants, in order to determine whether virtual reality exposure therapy has a different impact on regional brain activation than other therapies for PTSD.

  3. Acute and subacute effects of EV iron sucrose on endothelial functions in hemodialysis patients.

    PubMed

    Ozkurt, Sultan; Ozenc, Fatma; Degirmenci, Nevbahar Akcar; Temiz, Gokhan; Musmul, Ahmet; Sahin, Garip; Yalcin, Ahmet Ugur

    2012-01-01

    Iron support is an important component of treatment of anemia in hemodialysis (HD) patients. However, there are concerns about endovenous (EV) iron therapy that may cause endothelial dysfunction (ED) by increasing oxidative stress (OS) and lead to cardiovascular events. In this study, we aimed to evaluate the effects of high and repeated doses of EV iron sucrose on endothelial functions in acute and subacute phases. We included 15 HD patients to our study. There were 16 patients with iron deficiency but normal kidney functions in control group. We also evaluated endothelium-dependent vasodilatation (EDV) and nitroglycerin-induced vasodilatation (NIV) from the brachial artery by ultrasonography at the beginning of the study, and then 200 mg EV iron sucrose was given initially to both groups for 1 h in 250 cc 0.9% saline and 4 h after the end of the infusion (acute phase) sonographic vasodilatation parameters were measured from brachial artery. These measurements and laboratory tests were repeated 1 week after the end of a total 1000 mg EV iron sucrose replacement (200 mg/week). There was a statistically significant increase in hemoglobin and ferritin levels after the EV iron sucrose therapy in both control and patient groups. EDV values in the HD group were significantly lower than that in the control group before therapy (6.25% vs. 10.53%, p < 0.05). EV iron sucrose therapy did not alter EDV and NIV values at the 4th hour and 6th week in both control and patient groups. According to our study, compared with the control group with normal kidney functions, HD patients had impaired endothelial functions. However, in HD patients, high and repeated doses of EV iron sucrose do not have deleterious effects on endothelial functions at acute and subacute phases and can be used safely in that patient group.

  4. Improved repeatability of nasal potential difference with a larger surface catheter.

    PubMed

    Vermeulen, François; Proesmans, Marijke; Boon, Mieke; De Boeck, Kris

    2015-05-01

    To increase the power of nasal potential difference (NPD) as a biomarker of CFTR function, improvement of its repeatability is needed. We evaluated the improvement in repeatability resulting from measuring NPD (1) over a larger surface area and (2) at a fixed location. To assess repeatability, NPD was measured on two occasions with a new method using a larger surface catheter at fixed locations on the nasal floor (LSC-floor(5cm) and LSC-floor(3cm)) or at the most negative basal potential (LSC-floor(max)); with a sidehole catheter on the nasal floor at 5 cm) from the nasal margin (SHC-floor(5cm)) or at the most negative potential (SHC-floor(max)); and with an endhole catheter below the inferior surface of the lower turbinate at the most negative potential (EHC-turb(max)). The within-subject standard deviation (S(w)) for repeated measurements of the total chloride response in the controls was smallest with the LSC-floor at a fixed location (LSC-floor(5cm) 3.1 mV; 95% CI 2.3-4.6 mV) and highest with the SHC-floor (SHC-floor(max) 14.6 mV; 95% CI 10.9-22.2 mV) or the EHC-turbinate (EHC-turb(max) 12.5 mV; 95% CI 10.7-23.0 mV) at the most negative basal potential. Measuring with the LSC-floor at the maximal potential increased the Sw (LSC-floor(max) 8.8 mV, 95% CI 6.0-16.1 mV, p=0.009 vs LSC-floor(5cm)), while measuring with the SHC-floor at a fixed location slightly decreased the Sw (SHC-floor(5cm) 9.8 mV, 95% CI 8.9-20.6 mV, p=0.06 vs SHC-floor(max)). In patients with cystic fibrosis, the S(w) was comparable, between 2.2 mV and 4.3 mV. Sample size calculations for trials using NPD to assess changes in ion transport showed that the number of subjects to be included could be approximately halved measuring with the larger surface catheter at a fixed location vs SHC or EHC at fixed locations. Measuring the NPD at a fixed location and over a larger surface resulted in increased repeatability and thereby also power as a biomarker of CFTR modulation. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  5. Within-session effect of repeated stress exposure on extinction circuitry function in social anxiety disorder.

    PubMed

    Åhs, Fredrik; Gingnell, Malin; Furmark, Tomas; Fredrikson, Mats

    2017-03-30

    Anxiety reduction following repeated exposure to stressful experiences is generally held to depend on neural processes involved in extinction of conditioned fear. We predicted that repeated exposure to stressful experiences would change activity throughout the circuitry serving extinction, including ventromedial prefrontal cortex (vmPFC), the hippocampus and the amygdala. To test this prediction, 36 participants diagnosed with SAD performed two successive speeches in front of an observing audience while regional cerebral blood flow (rCBF) was recorded using positron emission tomography. To control for non-anxiolytic effects of repeated exposure, rCBF was also measured during repeated presentations of neutral and angry facial expressions. Results showed that anxiety ratings and heart rate decreased from the first to the second speech, indicating an anxiolytic effect of repeated exposure. Exposure attenuated rCBF in the amygdala whereas no change in rCBF was observed in the vmPFC or hippocampus. The rCBF-reductions in the amygdala were greater following repetition of the speech task than repetition of face exposure indicating that they were specific to anxiety attenuation and not due to a reduced novelty. Our findings suggest that amygdala-related attenuation processes are key to understanding the working mechanisms of exposure therapy. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Biosafety Risk Assessment Methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caskey, Susan Adele; Gaudioso, Jennifer M.; Salerno, Reynolds Mathewson

    2010-10-01

    Laboratories that work with biological agents need to manage their safety risks to persons working the laboratories and the human and animal community in the surrounding areas. Biosafety guidance defines a wide variety of biosafety risk mitigation measures, which include measures which fall under the following categories: engineering controls, procedural and administrative controls, and the use of personal protective equipment; the determination of which mitigation measures should be used to address the specific laboratory risks are dependent upon a risk assessment. Ideally, a risk assessment should be conducted in a manner which is standardized and systematic which allows it tomore » be repeatable and comparable. A risk assessment should clearly define the risk being assessed and avoid over complication.« less

  7. Longer Eye Contact Improves ADHD Children's Compliance with Parents' Commands

    ERIC Educational Resources Information Center

    Kapalka, G. M.

    2004-01-01

    This study evaluated the effectiveness of eye contact in reducing ADHD children's problems with compliance. Seventy-six parents of ADHD boys between ages 5 and 10 were randomized into two treatment groups and a control group. Repeated-measures ANOVA revealed that, as hypothesized, eye contact was effective in reducing ADHD children's problems with…

  8. Positive Psychology Course and Its Relationship to Well-Being, Depression, and Stress

    ERIC Educational Resources Information Center

    Goodmon, Leilani B.; Middleditch, Ashlea M.; Childs, Bethany; Pietrasiuk, Stacey E.

    2016-01-01

    The purpose of this study was to determine the influence of a positive psychology course on student well-being, depressive symptoms, and stress in a repeated measure, nonequivalent control design. As hypothesized, the positive psychology students reported higher overall happiness, life satisfaction, routes to happiness, and lower depressive…

  9. Design-Comparable Effect Sizes in Multiple Baseline Designs: A General Modeling Framework

    ERIC Educational Resources Information Center

    Pustejovsky, James E.; Hedges, Larry V.; Shadish, William R.

    2014-01-01

    In single-case research, the multiple baseline design is a widely used approach for evaluating the effects of interventions on individuals. Multiple baseline designs involve repeated measurement of outcomes over time and the controlled introduction of a treatment at different times for different individuals. This article outlines a general…

  10. A Standardized Mean Difference Effect Size for Multiple Baseline Designs across Individuals

    ERIC Educational Resources Information Center

    Hedges, Larry V.; Pustejovsky, James E.; Shadish, William R.

    2013-01-01

    Single-case designs are a class of research methods for evaluating treatment effects by measuring outcomes repeatedly over time while systematically introducing different condition (e.g., treatment and control) to the same individual. The designs are used across fields such as behavior analysis, clinical psychology, special education, and…

  11. Repeated Strains, Social Control, Social Learning, and Delinquency: Testing an Integrated Model of General Strain Theory in China

    ERIC Educational Resources Information Center

    Bao, Wan-Ning; Haas, Ain; Chen, Xiaojin; Pi, Yijun

    2014-01-01

    In Agnew's general strain theory, repeated strains can generate crime and delinquency by reducing social control and fostering social learning of crime. Using a sample of 615 middle-and high-school students in China, this study examines how social control and social learning variables mediate the effect of repeated strains in school and at home on…

  12. Foot orthoses for adults with flexible pes planus: a systematic review.

    PubMed

    Banwell, Helen A; Mackintosh, Shylie; Thewlis, Dominic

    2014-04-05

    Foot orthoses are widely used in the management of flexible pes planus, yet the evidence to support this intervention has not been clearly defined. This systematic review aimed to critically appraise the evidence for the use of foot orthoses for flexible pes planus in adults. Electronic databases (Medline, CINAHL, Cochrane, Web of science, SportDiscus, Embase) were systematically searched in June 2013 for randomised controlled, controlled clinical and repeated measure trials where participants had identified flexible pes planus using a validated and reliable measure of pes planus and the intervention was a rigid or semi-rigid orthoses with the comparison being a no-orthoses (shoes alone or flat non-posted insert) condition. Outcomes of interest were foot pain, rearfoot kinematics, foot kinetics and physical function. Of the 2,211 articles identified by the searches, 13 studies met the inclusion criteria; two were randomised controlled trials, one was a controlled trial and 10 were repeated measure studies. Across the included studies, 59 relevant outcome measures were reported with 17 calculated as statistically significant large or medium effects observed with use of foot orthoses compared to the no orthoses condition (SMD range 1.13 to -4.11). No high level evidence supported the use of foot orthoses for flexible pes planus. There is good to moderate level evidence that foot orthoses improve physical function (medial-lateral sway in standing (level II) and energy cost during walking (level III)). There is low level evidence (level IV) that foot orthoses improve pain, reduce rearfoot eversion, alter loading and impact forces; and reduce rearfoot inversion and eversion moments in flexible pes planus. Well-designed randomised controlled trials that include appropriate sample sizes, clinical cohorts and involve a measure of symptom change are required to determine the efficacy of foot orthoses to manage adult flexible pes planus.

  13. Foot orthoses for adults with flexible pes planus: a systematic review

    PubMed Central

    2014-01-01

    Background Foot orthoses are widely used in the management of flexible pes planus, yet the evidence to support this intervention has not been clearly defined. This systematic review aimed to critically appraise the evidence for the use of foot orthoses for flexible pes planus in adults. Methods Electronic databases (Medline, CINAHL, Cochrane, Web of science, SportDiscus, Embase) were systematically searched in June 2013 for randomised controlled, controlled clinical and repeated measure trials where participants had identified flexible pes planus using a validated and reliable measure of pes planus and the intervention was a rigid or semi-rigid orthoses with the comparison being a no-orthoses (shoes alone or flat non-posted insert) condition. Outcomes of interest were foot pain, rearfoot kinematics, foot kinetics and physical function. Results Of the 2,211 articles identified by the searches, 13 studies met the inclusion criteria; two were randomised controlled trials, one was a controlled trial and 10 were repeated measure studies. Across the included studies, 59 relevant outcome measures were reported with 17 calculated as statistically significant large or medium effects observed with use of foot orthoses compared to the no orthoses condition (SMD range 1.13 to -4.11). Conclusions No high level evidence supported the use of foot orthoses for flexible pes planus. There is good to moderate level evidence that foot orthoses improve physical function (medial-lateral sway in standing (level II) and energy cost during walking (level III)). There is low level evidence (level IV) that foot orthoses improve pain, reduce rearfoot eversion, alter loading and impact forces; and reduce rearfoot inversion and eversion moments in flexible pes planus. Well-designed randomised controlled trials that include appropriate sample sizes, clinical cohorts and involve a measure of symptom change are required to determine the efficacy of foot orthoses to manage adult flexible pes planus. PMID:24708560

  14. Applicability of refractometry for fast routine checking of hospital preparations.

    PubMed

    Hendrickx, Stijn; Verón, Aurora Monteagudo; Van Schepdael, Ann; Adams, Erwin

    2016-04-30

    Quality control of hospital pharmacy formulations is of the utmost importance to ensure constant quality and to avoid potential mistakes before administration to the patient. In this study we investigated the applicability of refractometry as a fast, inexpensive and easy-to-use quality control measurement. Refractive indices (RI) of a multitude of different hospital formulations with varying concentrations of active compound were measured. The samples consisted of a number of binary aqueous solutions (one compound in water), complex aqueous solutions (multiple compounds in water or in a constant matrix), two suspensions and one emulsion. For all these formulations, linear regression analysis was performed, quality control limits determined and accuracy and repeatability were checked. Subsequently, actual hospital pharmacy samples were analyzed to check whether they were within the specified limits. For both binary and complex aqueous formulations, repeatability was good and a linear correlation for all samples could be observed on condition that the concentration of the active compound was sufficiently high. The refractometer was not sensitive enough for solutions of folic acid and levothyroxine, which had too low a concentration of active compound. Due to lack of homogeneity and light scattering, emulsions and suspensions do not seem suitable for quality control by refractometry. A mathematical equation was generated to predict the refractive index of an aqueous solution containing clonidine HCl as active compound. Values calculated from the equation were compared with measured values and deviations of all samples were found to be lower than 1.3%. In order to use refractometry in a hospital pharmacy for quality control of multicomponent samples, additional intermediate measurements would be required, to overcome the fact that refractometry is not compound specific. In conclusion, we found that refractometry could potentially be useful for daily, fast quality measurements of relatively concentrated binary and more complex aqueous solutions in the hospital pharmacy. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. The initial effects of a sustained glenohumeral postero-lateral glide during elevation on shoulder muscle activity: A repeated measures study on asymptomatic shoulders.

    PubMed

    Ribeiro, Daniel Cury; de Castro, Marcelo Peduzzi; Sole, Gisela; Vicenzino, Bill

    2016-04-01

    Manual therapy enhances pain-free range of motion and reduces pain levels, but its effect on shoulder muscle activity is unclear. This study aimed to assess the effects of a sustained glenohumeral postero-lateral glide during elevation on shoulder muscle activity. Thirty asymptomatic individuals participated in a repeated measures study of the electromyographic activity of the supraspinatus, infraspinatus, posterior deltoid, and middle deltoid. Participants performed four sets of 10 repetitions of shoulder scaption and abduction with and without a glide of the glenohumeral joint. Repeated-measures multivariate analysis of variance (MANOVA) was used to assess the effects of movement direction (scaption and abduction), and condition (with and without glide) (within-subject factors) on activity level of each muscle (dependent variables). Significant MANOVAs were followed-up with repeated-measures one-way analysis of variance. During shoulder scaption with glide, the supraspinatus showed a reduction of 4.1% maximal isometric voluntary contraction (MVIC) (95% CI 2.4, 5.8); and infraspinatus 1.3% MVIC (95% CI 0.5, 2.1). During shoulder abduction with a glide, supraspinatus presented a reduction of 2.5% MVIC (95% CI 1.1, 4.0), infraspinatus 2.1% MVIC (95% CI 1.0, 3.2), middle deltoid 2.2% MVIC (95% CI = 0.4, 4.1), posterior deltoid 2.1% MVIC (95% CI 1.3, 2.8). In asymptomatic individuals, sustained glide reduced shoulder muscle activity compared to control conditions. This might be useful in enhancing shoulder movement in clinical populations. Reductions in muscle activity might result from altered joint mechanics, including simply helping to lift the arm, and/or through changing afferent sensory input about the shoulder. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Diagnostic value of repeated ice tests in the evaluation of ptosis in myasthenia gravis.

    PubMed

    Park, Jun Young; Yang, Hee Kyung; Hwang, Jeong-Min

    2017-01-01

    Twenty-six patients with ptosis related to Myasthenia gravis (MG) and 38 controls with ptosis other than MG were included. All patients were tested with the ice test 2 times on separate days in the afternoon. The margin reflex distance (MRD) was measured before and immediately after 2-minute application of ice on the eyelids. The ice test was judged positive if there was an improvement of at least 2.0 mm of MRD after the ice test. Among the patients with negative test results, 'equivocal' was defined by improvement of MRD from at least 1.0 mm to less than 2.0 mm after the ice test. Repeated ice test results showed an agreement of 61.5% in MG, and 97.4% in nonmyasthenic ptosis. Repeated ice tests increased the sensitivity by 34.6% compared to a single test. Among the patients with repeatedly negative test results, 63.6% of those who showed equivocal results at least once turned out to be MG. Of those with repeated non-equivocal negative results, nobody turned out to be MG. There was no significant difference of the ice test results between ocular MG and generalized MG (p = 0.562).

  17. Diagnostic value of repeated ice tests in the evaluation of ptosis in myasthenia gravis

    PubMed Central

    2017-01-01

    Twenty-six patients with ptosis related to Myasthenia gravis (MG) and 38 controls with ptosis other than MG were included. All patients were tested with the ice test 2 times on separate days in the afternoon. The margin reflex distance (MRD) was measured before and immediately after 2-minute application of ice on the eyelids. The ice test was judged positive if there was an improvement of at least 2.0 mm of MRD after the ice test. Among the patients with negative test results, 'equivocal’ was defined by improvement of MRD from at least 1.0 mm to less than 2.0 mm after the ice test. Repeated ice test results showed an agreement of 61.5% in MG, and 97.4% in nonmyasthenic ptosis. Repeated ice tests increased the sensitivity by 34.6% compared to a single test. Among the patients with repeatedly negative test results, 63.6% of those who showed equivocal results at least once turned out to be MG. Of those with repeated non-equivocal negative results, nobody turned out to be MG. There was no significant difference of the ice test results between ocular MG and generalized MG (p = 0.562). PMID:28562609

  18. The effects of test-enhanced learning on long-term retention in AAN annual meeting courses.

    PubMed

    Larsen, Douglas P; Butler, Andrew C; Aung, Wint Y; Corboy, John R; Friedman, Deborah I; Sperling, Michael R

    2015-02-17

    We measured the long-term retention of knowledge gained through selected American Academy of Neurology annual meeting courses and compared the effects of repeated quizzing (known as test-enhanced learning) and repeated studying on that retention. Participants were recruited from 4 annual meeting courses. All participants took a pretest. This randomized, controlled trial utilized a within-subjects design in which each participant experienced 3 different postcourse activities with each activity performed on different material. Each key information point from the course was randomized in a counterbalanced fashion among participants to one of the 3 activities: repeated short-answer quizzing, repeated studying, and no further exposure to the materials. A final test covering all information points from the course was taken 5.5 months after the course. Thirty-five participants across the 4 courses completed the study. Average score on the pretest was 36%. Performance on the final test showed that repeated quizzing led to significantly greater long-term retention relative to both repeated studying (55% vs 46%; t[34] = 3.28, SEM = 0.03, p = 0.01, d = 0.49) and no further exposure (55% vs 44%; t[34] = 3.16, SEM = 0.03, p = 0.01, d = 0.58). Relative to the pretest baseline, repeated quizzing helped participants to retain almost twice as much of the knowledge acquired from the course compared to repeated studying or no further exposure. Whereas annual meeting continuing medical education (CME) courses lead to long-term gains in knowledge, when repeated quizzing is added, retention is significantly increased. CME planners may consider adding repeated quizzing to increase the impact of their courses. © 2015 American Academy of Neurology.

  19. The effects of test-enhanced learning on long-term retention in AAN annual meeting courses

    PubMed Central

    Butler, Andrew C.; Aung, Wint Y.; Corboy, John R.; Friedman, Deborah I.; Sperling, Michael R.

    2015-01-01

    Objective: We measured the long-term retention of knowledge gained through selected American Academy of Neurology annual meeting courses and compared the effects of repeated quizzing (known as test-enhanced learning) and repeated studying on that retention. Methods: Participants were recruited from 4 annual meeting courses. All participants took a pretest. This randomized, controlled trial utilized a within-subjects design in which each participant experienced 3 different postcourse activities with each activity performed on different material. Each key information point from the course was randomized in a counterbalanced fashion among participants to one of the 3 activities: repeated short-answer quizzing, repeated studying, and no further exposure to the materials. A final test covering all information points from the course was taken 5.5 months after the course. Results: Thirty-five participants across the 4 courses completed the study. Average score on the pretest was 36%. Performance on the final test showed that repeated quizzing led to significantly greater long-term retention relative to both repeated studying (55% vs 46%; t[34] = 3.28, SEM = 0.03, p = 0.01, d = 0.49) and no further exposure (55% vs 44%; t[34] = 3.16, SEM = 0.03, p = 0.01, d = 0.58). Relative to the pretest baseline, repeated quizzing helped participants to retain almost twice as much of the knowledge acquired from the course compared to repeated studying or no further exposure. Conclusions: Whereas annual meeting continuing medical education (CME) courses lead to long-term gains in knowledge, when repeated quizzing is added, retention is significantly increased. CME planners may consider adding repeated quizzing to increase the impact of their courses. PMID:25609761

  20. The effects of saliva collection, handling and storage on salivary testosterone measurement.

    PubMed

    Durdiaková, Jaroslava; Fábryová, Helena; Koborová, Ivana; Ostatníková, Daniela; Celec, Peter

    2013-12-20

    Several endocrine parameters commonly measured in plasma, such as steroid hormones, can be measured in the oral fluid. However, there are several technical aspects of saliva sampling and processing that can potentially bias the validity of salivary testosterone measurement. The aim of this study was to evaluate the effects caused by repeated sampling; 5 min centrifugation (at 2000, 6000 or 10,000g); the stimulation of saliva flow by a cotton swab soaked in 2% citric acid touching the tongue; different storage times and conditions as well as the impact of blood contamination on salivary testosterone concentration measured using a commercially available ELISA kit. Fresh, unprocessed, unstimulated saliva samples served as a control. Salivary testosterone concentrations were influenced neither by repeated sampling nor by stimulation of salivary flow. Testosterone levels determined in samples stored in various laboratory conditions for time periods up to 1 month did not differ in comparison with controls. For both genders, salivary testosterone levels were substantially reduced after centrifugation (men F=29.1; women F=56.17, p<0.0001). Blood contamination decreased salivary testosterone levels in a dose-dependent manner (men F=6.54, p<0.01, F=5.01, p<0.05). Salivary testosterone can be considered A robust and stable marker. However, saliva processing and blood leakage can introduce bias into measurements of salivary testosterone using ELISA. Our observations should be considered in studies focusing on salivary testosterone. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Polymorphic CAG Repeat Numbers in the Androgen Receptor Gene of Female Pattern Hair Loss in a Han Chinese Population.

    PubMed

    Rui, Wenlong; Sheng, Youyu; Hu, Ruiming; Miao, Ying; Han, Yumei; Qi, Sisi; Xu, Feng; Xu, Jinhua; Yang, Qinping

    2016-01-01

    To investigate the association of CAG repeat numbers in the androgen receptor (AR) gene with female pattern hair loss (FPHL) in a Chinese population. A total of 200 Han Chinese patients with FPHL (142 Ludwig II and 58 Ludwig III cases) and 200 healthy controls were enrolled in this study. The polymorphism of CAG repeat numbers was analyzed by the fluorescent amplified fragment length polymorphism technique. The CAG biallelic mean length was 23.73 ± 2.04 repeats in Han Chinese FPHL patients and 23.90 ± 2.13 repeats in healthy controls, without any significant difference between the two groups (p = 0.481). In addition, neither the shorter nor the longer CAG repeat numbers were significantly different between FPHL and control subjects (p = 0.726, p = 0.383). The polymorphism of CAG repeat numbers of the AR gene may not be the genetic marker of FPHL in a Chinese population. © 2016 S. Karger AG, Basel.

  2. Validity and repeatability of inertial measurement units for measuring gait parameters.

    PubMed

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Rapidly deployable emergency communication system

    DOEpatents

    Gladden, Charles A.; Parelman, Martin H.

    1979-01-01

    A highly versatile, highly portable emergency communication system which permits deployment in a very short time to cover both wide areas and distant isolated areas depending upon mission requirements. The system employs a plurality of lightweight, fully self-contained repeaters which are deployed within the mission area to provide communication between field teams, and between each field team and a mobile communication control center. Each repeater contains a microcomputer controller, the program for which may be changed from the control center by the transmission of digital data within the audible range (300-3,000 Hz). Repeaters are accessed by portable/mobile transceivers, other repeaters, and the control center through the transmission and recognition of digital data code words in the subaudible range.

  4. The effect of cold application on pain due to chest tube removal.

    PubMed

    Ertuğ, Nurcan; Ulker, Saadet

    2012-03-01

    The aim of the research is to determine the effect of cold application on the pain owing to chest tube removal for patients with single pleural chest tube. Removal of chest tubes causes patients to feel pain and interventions used for reducing the pain owing to the removal of chest tubes are not sufficient. Controlled clinical trial with repeated measures. This study was conducted with 140 patients, of whom 70 patients were in the experimental group and 70 patients were in the control group, in a thoracic hospital in Turkey. Data were collected using a data collection form consisting of patients' demographic and health history and Visual Analogue Scale. Cold was applied to patients in the experimental group prior to chest tube removal. In the experimental group, skin temperature and pain intensity was measured for each patient at four time points. In the control group, pain intensity was evaluated for each patient at three time points. Data were evaluated using Chi-square and Repeated Measurements two-way anova tests. The Visual Analogue Scale score was measured immediately after the chest tube removal in the experimental group was 3·85, compared with 5·60 in the control group. There were significant differences on pain with cold application between the two groups prior and after the intervention. Age, gender, the number of days the chest tube was inserted and the chest tube insertion indication had no effect on the pain owing to chest tube removal. Cold application is effective in reducing the pain owing to chest tube removal. Cold application was recommended prior to chest tube removal to reduce the pain owing to removal of chest tube. © 2011 Blackwell Publishing Ltd.

  5. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    NASA Astrophysics Data System (ADS)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  6. Arsenic Speciation and Accumulation in Selected Organs after Oral Administration of Rice Extracts in Wistar Rats.

    PubMed

    Lewchalermvong, Kittima; Rangkadilok, Nuchanart; Nookabkaew, Sumontha; Suriyo, Tawit; Satayavivad, Jutamaad

    2018-03-28

    Despite its nutritional values, rice also contains arsenic. There has been increasing concern about health implications associated with exposure to arsenic through rice consumption. The present study evaluated arsenic accumulation and its speciation in selected organs of Wistar rats after 28 day repeated oral administrations of polished or unpolished rice and their control arsenic compounds (sodium arsenite or dimethylarsinic acid; DMA). Only the treatment of sodium arsenite (2 μg/kg body weight), significantly increased total arsenic concentrations in blood when compared to the distilled water control group. In all groups, total arsenic concentrations were highest in kidney (1.54-1.90 mg/kg) followed by liver (0.85-1.52 mg/kg), and the predominant arsenic form in these organs was DMA. However, there was no significant difference in arsenic accumulation in the measured organs among the control and rice-treated groups. Therefore, the repeated 28 day administration of arsenic-contaminated rice did not cause significant arsenic accumulation in the animal organs.

  7. Repeatability of DTI-based skeletal muscle fiber tracking

    PubMed Central

    Heemskerk, Anneriet M.; Sinha, Tuhin K.; Wilson, Kevin J.; Ding, Zhaohua; Damon, Bruce M.

    2015-01-01

    Diffusion tensor imaging (DTI)-based muscle fiber tracking enables the measurement of muscle architectural parameters, such as pennation angle (θ) and fiber tract length (Lft), throughout the entire muscle. Little is known, however, about the repeatability of either the muscle architectural measures or the underlying diffusion measures. Therefore, the goal of this study was to investigate the repeatability of DTI fiber tracking-based measurements and θ and Lft. Four DTI acquisitions were performed on two days that allowed for between acquisition, within day, and between day analyses. The eigenvalues and fractional anisotropy were calculated at the maximum cross-sectional area of, and fiber tracking was performed in, the tibialis anterior muscle of nine healthy subjects. The between acquisitions condition had the highest repeatability for the DTI indices and the architectural parameters. The overall inter class correlation coefficients (ICC’s) were greater than 0.6 for both θ and Lft and the repeatability coefficients were θ <10.2° and Lft < 50 mm. In conclusion, under the experimental and data analysis conditions used, the repeatability of the diffusion measures is very good and repeatability of the architectural measurements is acceptable. Therefore, this study demonstrates the feasibility for longitudinal studies of alterations in muscle architecture using DTI-based fiber tracking, under similar noise conditions and with similar diffusion characteristics. PMID:20099372

  8. Satiety and energy intake after single and repeated exposure to gel-forming dietary fiber: post-ingestive effects.

    PubMed

    Wanders, A J; Mars, M; Borgonjen-van den Berg, K J; de Graaf, C; Feskens, E J M

    2014-06-01

    Viscous or gel-forming dietary fibers can increase satiety by a more firm texture and increased eating time. Effects of viscous or gel-forming fibers on satiety by post-ingestive mechanisms such as gastric emptying, hormonal signals, nutrient absorption or fermentation are unclear. Moreover, it is unclear whether the effects persist after repeated exposure. To investigate satiety and energy intake after single and repeated exposure to gelled fiber by post-ingestive mechanisms. In a two-arm crossover design, 32 subjects (24 female subjects, 21±2 y, BMI 21.8±1.9 kg m(-2)) consumed test foods once daily for 15 consecutive days, with 2 weeks of washout. Test foods were isocaloric (0.5 MJ, 200 g) with either 10 g gel-forming pectin or 3 g gelatin and 2 g starch, matched for texture and eating time. Hourly satiety ratings, ad libitum energy intake and body weight were measured on days 1 (single exposure) and 15 (repeated exposure). In addition, hourly breath hydrogen, fasting glucose, insulin, leptin and short-chain fatty acids were measured. Subjects rated hunger, desire to eat and prospective intake about 2% lower (P<0.015) and fullness higher (+1.4%; P=0.041) when they received pectin compared with control. This difference was similar after single and repeated exposure (P>0.64). After receiving pectin, energy intake was lower (-5.6%, P=0.012) and breath hydrogen was elevated (+12.6%, P=0.008) after single exposure, but not after repeated exposure. Fasting glucose concentrations were higher both after single and repeated exposure to pectin (+2.1%, P=0.019). Body weight and concentrations of insulin, leptin and short-chain fatty acids did not change during the study. Gelled pectin can increase satiety and reduce energy intake by post-ingestive mechanisms. Although the effects were small, the effects on satiety were consistent over time, whereas the effects on energy intake reduction were not.

  9. Oscillometric blood pressure devices and simulators: measurements of repeatability and differences between models.

    PubMed

    Sims, A J; Reay, C A; Bousfield, D R; Menes, J A; Murray, A

    2005-01-01

    To measure the repeatability and pressure pulse envelope of simulators used for testing oscillometric non-invasive blood pressure (NIBP) devices; to study the effect of different envelopes on NIBP devices, and to measure the difference between NIBP devices due to different oscillometric algorithms. Three different models of NIBP simulator and 18 different patient monitors with NIBP function were studied. We developed a pressure measurement system (accuracy 0.048?mmHg) to measure the repeatability of simulators. The effect of changing the envelope was measured by using three simulators with one NIBP device. Differences between 18 NIBP devices were measured using one simulator at seven blood pressure settings. Simulators generate repeatable pressure pulse envelopes (< 0.2 mmHg) but the magnitude and shape depends on the model of simulator. Oscillometric NIBP devices are highly repeatable (< 2 mmHg) when presented with a repeatable pressure pulse envelope, but different devices employ different algorithms and give different results. For a simulated standard blood pressure setting of 120/80 mmHg, estimates of systolic pressure ranged from 112.6 to 126.6 mmHg (sd of 3.0 mmHg), and diastolic pressure ranged from 74.8 to 86.9 mmHg (sd of 3.5 mmHg). Simulators and NIBP devices are sufficiently repeatable for clinical use, but further systematic clinical studies are required to better characterize the pressure pulse envelope for different patient groups.

  10. Active Control of Blade Tonals in Underwater Vehicles

    DTIC Science & Technology

    2006-12-01

    Because the stator is a streamlined shape the wake deficit responsible for blade tonal noise is due mainly to surface drag, which can be thought of as a... wake deficit , the vortex rollup at this stage is not very repeatable. Therefore, this type of wake may not be the best suited for controlling blade ...sinusoidal and non-sinusoidal move profiles. This model was also able to capture the baseline wake deficit measured. 2-dimensional blade interaction was

  11. Novel CO2 laser robotic controller outperforms experienced laser operators in tasks of accuracy and performance repeatability.

    PubMed

    Wong, Yu-Tung; Finley, Charles C; Giallo, Joseph F; Buckmire, Robert A

    2011-08-01

    To introduce a novel method of combining robotics and the CO(2) laser micromanipulator to provide excellent precision and performance repeatability designed for surgical applications. Pilot feasibility study. We developed a portable robotic controller that appends to a standard CO(2) laser micromanipulator. The robotic accuracy and laser beam path repeatability were compared to six experienced users of the industry standard micromanipulator performing the same simulated surgical tasks. Helium-neon laser beam video tracking techniques were employed. The robotic controller demonstrated superiority over experienced human manual micromanipulator control in accuracy (laser path within 1 mm of idealized centerline), 97.42% (standard deviation [SD] 2.65%), versus 85.11% (SD 14.51%), P = .018; and laser beam path repeatability (area of laser path divergence on successive trials), 21.42 mm(2) (SD 4.35 mm(2) ) versus 65.84 mm(2) (SD 11.93 mm(2) ), P = .006. Robotic micromanipulator control enhances accuracy and repeatability for specific laser tasks. Computerized control opens opportunity for alternative user interfaces and additional safety features. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  12. A rapid, controlled-environment seedling root screen for wheat correlates well with rooting depths at vegetative, but not reproductive, stages at two field sites

    PubMed Central

    Watt, M.; Moosavi, S.; Cunningham, S. C.; Kirkegaard, J. A.; Rebetzke, G. J.; Richards, R. A.

    2013-01-01

    Background and Aims Root length and depth determine capture of water and nutrients by plants, and are targets for crop improvement. Here we assess a controlled-environment wheat seedling screen to determine speed, repeatability and relatedness to performance of young and adult plants in the field. Methods Recombinant inbred lines (RILs) and diverse genotypes were grown in rolled, moist germination paper in growth cabinets, and primary root number and length were measured when leaf 1 or 2 were fully expanded. For comparison, plants were grown in the field and root systems were harvested at the two-leaf stage with either a shovel or a soil core. From about the four-leaf stage, roots were extracted with a steel coring tube only, placed directly over the plant and pushed to the required depth with a hydraulic ram attached to a tractor. Key Results In growth cabinets, repeatability was greatest (r = 0·8, P < 0·01) when the paper was maintained moist and seed weight, pathogens and germination times were controlled. Scanned total root length (slow) was strongly correlated (r = 0·7, P < 0·01) with length of the two longest seminal axile roots measured with a ruler (fast), such that 100–200 genotypes were measured per day. Correlation to field-grown roots at two sites at two leaves was positive and significant within the RILs and cultivars (r = 0·6, P = 0·01), and at one of the two sites at the five-leaf stage within the RILs (r = 0·8, P = 0·05). Measurements made in the field with a shovel or extracted soil cores were fast (5 min per core) and had significant positive correlations to scanner measurements after root washing and cleaning (>2 h per core). Field measurements at two- and five-leaf stages did not correlate with root depth at flowering. Conclusions The seedling screen was fast, repeatable and reliable for selecting lines with greater total root length in the young vegetative phase in the field. Lack of significant correlation with reproductive stage root system depth at the field sites used in this study reflected factors not captured in the screen such as time, soil properties, climate variation and plant phenology. PMID:23821620

  13. Projection of controlled repeatable real-time moving targets to test and evaluate motion imagery quality

    NASA Astrophysics Data System (ADS)

    Scopatz, Stephen D.; Mendez, Michael; Trent, Randall

    2015-05-01

    The projection of controlled moving targets is key to the quantitative testing of video capture and post processing for Motion Imagery. This presentation will discuss several implementations of target projectors with moving targets or apparent moving targets creating motion to be captured by the camera under test. The targets presented are broadband (UV-VIS-IR) and move in a predictable, repeatable and programmable way; several short videos will be included in the presentation. Among the technical approaches will be targets that move independently in the camera's field of view, as well targets that change size and shape. The development of a rotating IR and VIS 4 bar target projector with programmable rotational velocity and acceleration control for testing hyperspectral cameras is discussed. A related issue for motion imagery is evaluated by simulating a blinding flash which is an impulse of broadband photons in fewer than 2 milliseconds to assess the camera's reaction to a large, fast change in signal. A traditional approach of gimbal mounting the camera in combination with the moving target projector is discussed as an alternative to high priced flight simulators. Based on the use of the moving target projector several standard tests are proposed to provide a corresponding test to MTF (resolution), SNR and minimum detectable signal at velocity. Several unique metrics are suggested for Motion Imagery including Maximum Velocity Resolved (the measure of the greatest velocity that is accurately tracked by the camera system) and Missing Object Tolerance (measurement of tracking ability when target is obscured in the images). These metrics are applicable to UV-VIS-IR wavelengths and can be used to assist in camera and algorithm development as well as comparing various systems by presenting the exact scenes to the cameras in a repeatable way.

  14. Two-Dimensional Micro-/Nanoradian Angle Generator with High Resolution and Repeatability Based on Piezo-Driven Double-Axis Flexure Hinge and Three Capacitive Sensors.

    PubMed

    Tan, Xinran; Zhu, Fan; Wang, Chao; Yu, Yang; Shi, Jian; Qi, Xue; Yuan, Feng; Tan, Jiubin

    2017-11-19

    This study presents a two-dimensional micro-/nanoradian angle generator (2D-MNAG) that achieves high angular displacement resolution and repeatability using a piezo-driven flexure hinge for two-dimensional deflections and three capacitive sensors for output angle monitoring and feedback control. The principal error of the capacitive sensor for precision microangle measurement is analyzed and compensated for; so as to achieve a high angle output resolution of 10 nrad (0.002 arcsec) and positioning repeatability of 120 nrad (0.024 arcsec) over a large angular range of ±4363 μrad (±900 arcsec) for the 2D-MNAG. The impact of each error component, together with the synthetic error of the 2D-MNAG after principal error compensation are determined using Monte Carlo simulation for further improvement of the 2D-MNAG.

  15. Two-Dimensional Micro-/Nanoradian Angle Generator with High Resolution and Repeatability Based on Piezo-Driven Double-Axis Flexure Hinge and Three Capacitive Sensors

    PubMed Central

    Tan, Xinran; Zhu, Fan; Wang, Chao; Yu, Yang; Shi, Jian; Qi, Xue; Yuan, Feng; Tan, Jiubin

    2017-01-01

    This study presents a two-dimensional micro-/nanoradian angle generator (2D-MNAG) that achieves high angular displacement resolution and repeatability using a piezo-driven flexure hinge for two-dimensional deflections and three capacitive sensors for output angle monitoring and feedback control. The principal error of the capacitive sensor for precision microangle measurement is analyzed and compensated for; so as to achieve a high angle output resolution of 10 nrad (0.002 arcsec) and positioning repeatability of 120 nrad (0.024 arcsec) over a large angular range of ±4363 μrad (±900 arcsec) for the 2D-MNAG. The impact of each error component, together with the synthetic error of the 2D-MNAG after principal error compensation are determined using Monte Carlo simulation for further improvement of the 2D-MNAG. PMID:29156595

  16. A high stability and repeatability electrochemical scanning tunneling microscope.

    PubMed

    Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou

    2014-12-01

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO4(2-) image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  17. Automated computation of femoral angles in dogs from three-dimensional computed tomography reconstructions: Comparison with manual techniques.

    PubMed

    Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M

    2018-02-01

    The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Alcohol warnings in TV beer advertisements.

    PubMed

    Slater, M D; Domenech, M M

    1995-05-01

    Mandated warnings are among the few steps Congress has taken to influence the use of legal substances such as alcohol. The usefulness of such warnings in discouraging abuse of alcohol is, however, controversial. This study examines the impact of televised warnings on probable antecedents of belief change not examined in previous research: confidence in beliefs about beer risks or benefits, and cognitive responses to the advertisements. The present study (N = 75 male and female college students) tests four of the warnings recommended in Senate Bill 674 (1993--the "Thurmond bill") edited into randomly sampled television beer advertisements, using a between-subjects treatment-and-control experimental design. The four advertisements or advertisement/warning pairs were counterbalanced and analyzed as a repeated measures factor. The study indicated, as hypothesized, that subjects exposed to warnings tended to have less confidence in their generally skeptical assessments of beer risks--a likely precursor to belief change in resistant populations. Repeated exposure to the advertisements alone also appeared to lead to increased confidence in generally positive assessments of beer benefits, whereas repeated exposure to warnings led to decreased confidence in such assessments. Repeated exposure to warnings also may have primed negative reactions to subsequent beer advertisements. These results suggest mechanisms by which alcohol warnings may over time influence beliefs. Measures used here may serve as useful criterion variables in future studies on warnings. Further attention to optimizing warning content and presentation is recommended.

  19. Distribution of the FMR1 gene in females by race/ethnicity: women with diminished ovarian reserve versus women with normal fertility (SWAN study).

    PubMed

    Pastore, Lisa M; Young, Steven L; Manichaikul, Ani; Baker, Valerie L; Wang, Xin Q; Finkelstein, Joel S

    2017-01-01

    To study whether reported, but inconsistent, associations between the FMR1 CGG repeat lengths in the intermediate, high normal, or low normal range differentiate women diagnosed with diminished ovarian reserve (DOR) from population controls and whether associations vary by race/ethnic group. Case-control study. Academic and private fertility clinics. DOR cases (n = 129; 95 Whites, 22 Asian, 12 other) from five U.S. fertility clinics were clinically diagnosed, with regular menses and no fragile X syndrome family history. Normal fertility controls (n = 803; 386 Whites, 219 African-Americans, 102 Japanese, 96 Chinese) from the United States-based SWAN Study had one or more menstrual period in the 3 months pre-enrollment, one or more pregnancy, no history of infertility or hormone therapy, and menopause ≥46 years. Previously, the SWAN Chinese and Japanese groups had similar FMR1 CGG repeat lengths, thus they were combined. None. FMR1 CGG repeat lengths. Median CGG repeats were nearly identical by case/control group. DOR cases had fewer CGG repeats in the shorter FMR1 allele than controls among Whites, but this was not significant among Asians. White cases had fewer CGG repeats in the shorter allele than Asian cases. No significant differences were found in the high normal/intermediate range between cases and controls or by race/ethnic group within cases in the longer allele. This study refutes prior reports of an association between DOR and high normal/intermediate repeats and confirms an association between DOR and low normal repeats in Whites. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  20. Applications of low altitude photogrammetry for morphometry, displacements, and landform modeling

    NASA Astrophysics Data System (ADS)

    Gomez, F. G.; Polun, S. G.; Hickcox, K.; Miles, C.; Delisle, C.; Beem, J. R.

    2016-12-01

    Low-altitude aerial surveying is emerging as a tool that greatly improves the ease and efficiency of measuring landforms for quantitative geomorphic analyses. High-resolution, close-range photogrammetry produces dense, 3-dimensional point clouds that facilitate the construction of digital surface models, as well as a potential means of classifying ground targets using spatial structure. This study presents results from recent applications of UAS-based photogrammetry, including high resolution surface morphometry of a lava flow, repeat-pass applications to mass movements, and fault scarp degradation modeling. Depending upon the desired photographic resolution and the platform/payload flown, aerial photos are typically acquired at altitudes of 40 - 100 meters above the ground surface. In all cases, high-precision ground control points are key for accurate (and repeatable) orientation - relying on low-precision GPS coordinates (whether on the ground or geotags in the aerial photos) typically results in substantial rotations (tilt) of the reference frame. Using common ground control points between repeat surveys results in matching point clouds with RMS residuals better than 10 cm. In arid regions, the point cloud is used to assess lava flow surface roughness using multi-scale measurements of point cloud dimensionality. For the landslide study, the point cloud provides a basis for assessing possible displacements. In addition, the high resolution orthophotos facilitate mapping of fractures and their growth. For neotectonic applications, we compare fault scarp modeling results from UAV-derived point clouds versus field-based surveys (kinematic GPS and electronic distance measurements). In summary, there is a wide ranging toolbox of low-altitude aerial platforms becoming available for field geoscientists. In many instances, these tools will present convenience and reduced cost compared with the effort and expense to contract acquisitions of aerial imagery.

  1. THICKNESS OF THE MACULA, RETINAL NERVE FIBER LAYER, AND GANGLION CELL-INNER PLEXIFORM LAYER IN THE AGE-RELATED MACULAR DEGENERATION: The Repeatability Study of Spectral Domain Optical Coherence Tomography.

    PubMed

    Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul

    2018-02-01

    To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT < 200 μm; B group, 200 μm ≤ CMT < 300 μm; and C group, CMT > 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.

  2. Effect of acute and repeated restraint stress on glucose oxidation to CO2 in hippocampal and cerebral cortex slices.

    PubMed

    Torres, I L; Gamaro, G D; Silveira-Cucco, S N; Michalowski, M B; Corrêa, J B; Perry, M L; Dalmaz, C

    2001-01-01

    It has been suggested that glucocorticoids released during stress might impair neuronal function by decreasing glucose uptake by hippocampal neurons. Previous work has demonstrated that glucose uptake is reduced in hippocampal and cerebral cortex slices 24 h after exposure to acute stress, while no effect was observed after repeated stress. Here, we report the effect of acute and repeated restraint stress on glucose oxidation to CO2 in hippocampal and cerebral cortex slices and on plasma glucose and corticosterone levels. Male adult Wistar rats were exposed to restraint 1 h/day for 50 days in the chronic model. In the acute model there was a single exposure. Immediately or 24 h after stress, the animals were sacrificed and the hippocampus and cerebral cortex were dissected, sliced, and incubated with Krebs buffer, pH 7.4, containing 5 mM glucose and 0.2 microCi D-[U-14C] glucose. CO2 production from glucose was estimated. Trunk blood was also collected, and both corticosterone and glucose were measured. The results showed that corticosterone levels after exposure to acute restraint were increased, but the increase was smaller when the animals were submitted to repeated stress. Blood glucose levels increased after both acute and repeated stress. However, glucose utilization, measured as CO2 production in hippocampal and cerebral cortex slices, was the same in stressed and control groups under conditions of both acute and chronic stress. We conclude that, although stress may induce a decrease in glucose uptake, this effect is not sufficient to affect the energy metabolism of these cells.

  3. Consistent individual differences in the social phenotypes of wild great tits, Parus major

    PubMed Central

    Aplin, L.M.; Firth, J.A.; Farine, D.R.; Voelkl, B.; Crates, R.A.; Culina, A.; Garroway, C.J.; Hinde, C.A.; Kidd, L.R.; Psorakis, I.; Milligan, N.D.; Radersma, R.; Verhelst, B.L.; Sheldon, B.C.

    2015-01-01

    Despite growing interest in animal social networks, surprisingly little is known about whether individuals are consistent in their social network characteristics. Networks are rarely repeatedly sampled; yet an assumption of individual consistency in social behaviour is often made when drawing conclusions about the consequences of social processes and structure. A characterization of such social phenotypes is therefore vital to understanding the significance of social network structure for individual fitness outcomes, and for understanding the evolution and ecology of individual variation in social behaviour more broadly. Here, we measured foraging associations over three winters in a large PIT-tagged population of great tits, and used a range of social network metrics to quantify individual variation in social behaviour. We then examined repeatability in social behaviour over both short (week to week) and long (year to year) timescales, and investigated variation in repeatability across age and sex classes. Social behaviours were significantly repeatable across all timescales, with the highest repeatability observed in group size choice and unweighted degree, a measure of gregariousness. By conducting randomizations to control for the spatial and temporal distribution of individuals, we further show that differences in social phenotypes were not solely explained by within-population variation in local densities, but also reflected fine-scale variation in social decision making. Our results provide rare evidence of stable social phenotypes in a wild population of animals. Such stable social phenotypes can be targets of selection and may have important fitness consequences, both for individuals and for their social-foraging associates. PMID:26512142

  4. Video camera system for locating bullet holes in targets at a ballistics tunnel

    NASA Technical Reports Server (NTRS)

    Burner, A. W.; Rummler, D. R.; Goad, W. K.

    1990-01-01

    A system consisting of a single charge coupled device (CCD) video camera, computer controlled video digitizer, and software to automate the measurement was developed to measure the location of bullet holes in targets at the International Shooters Development Fund (ISDF)/NASA Ballistics Tunnel. The camera/digitizer system is a crucial component of a highly instrumented indoor 50 meter rifle range which is being constructed to support development of wind resistant, ultra match ammunition. The system was designed to take data rapidly (10 sec between shoots) and automatically with little operator intervention. The system description, measurement concept, and procedure are presented along with laboratory tests of repeatability and bias error. The long term (1 hour) repeatability of the system was found to be 4 microns (one standard deviation) at the target and the bias error was found to be less than 50 microns. An analysis of potential errors and a technique for calibration of the system are presented.

  5. X-ray tomography characterization of density gradient aerogel in laser targets

    NASA Astrophysics Data System (ADS)

    Borisenko, L.; Orekhov, A.; Musgrave, C.; Nazarov, W.; Merkuliev, Yu; Borisenko, N.

    2016-04-01

    The low-density solid laser target characterization studies begun with the SkyScan 1074 computer microtomograph (CMT) [1, 2] are now continued with higher resolution of SkyScan 1174. The research is particularly focused on the possibility to obtain, control and measure precisely the gradient density polymers for laser target production. Repeatability of the samples and possibility to obtain stable gradients are analysed. The measurements were performed on the mm-scale divinyl benzene (DVB) rods.

  6. Monoamine oxidase A inhibitor occupancy during treatment of major depressive episodes with moclobemide or St. John's wort: an [11C]-harmine PET study.

    PubMed

    Sacher, Julia; Houle, Sylvain; Parkes, Jun; Rusjan, Pablo; Sagrati, Sandra; Wilson, Alan A; Meyer, Jeffrey H

    2011-11-01

    Monoamine oxidase A (MAO-A) inhibitor antidepressants raise levels of multiple monoamines, whereas the selective serotonin reuptake inhibitors (SSRIs) only raise extracellular serotonin. Despite this advantage of MAO-A inhibitors, there is much less frequent development of MAO inhibitors compared with SSRIs. We sought to measure brain MAO-A occupancy after 6 weeks of treatment in depressed patients with a clinically effective dose of a selective MAO-A inhibitor and measure MAO-A occupancy after repeated administration of St. John's wort, an herb purported to have MAO-A inhibitor properties. Participants underwent 2 [(11)C]-harmine positron emission tomography scans. Healthy controls completed a test-retest condition, and depressed patients were scanned before and after repeated administration of moclobemide or St. John's wort for 6 weeks at the assigned dose. We measured MAO-A VT, an index of MAO-A density, in the prefrontal, anterior cingulate and anterior temporal cortices, putamen, thalamus, midbrain and hippocampus. We included 23 participants (10 controls and 13 patients with major depressive disorder [MDD]) in our study. Monoamine oxidase A VT decreased significantly throughout all regions after moclobemide treatment in patients with MDD compared with controls (repeated-measures analysis of variance, F1,15 = 71.08-130.06, p < 0.001 for all regions, mean occupancy 74% [standard deviation 6%]). Treatment with St. John's wort did not significantly alter MAO-A VT. The occupancy estimates are limited by the sample size of each treatment group; hence, our estimate for the overall moclobemide occupancy of 74% has a 95% confidence interval of 70%-78%, and we can estimate with 95% certainty that the occupancy of St. John's wort is less than 5%. For new MAO-A inhibitors, about 74% occupancy at steady-state dosing is desirable. Consistent with this, St. John's wort should not be classified as an MAO-A inhibitor. The magnitude of MAO-A blockade during moclobemide treatment exceeds the elevation of MAO-A binding during illness by at least 30%, suggesting that the treatment effect should exceed the disease effect when designing selective antidepressants for this target. © 2011 Canadian Medical Association

  7. A comparison of manual and controlled-force attachment-level measurements.

    PubMed

    Reddy, M S; Palcanis, K G; Geurs, N C

    1997-12-01

    This study compared the intra-examiner and inter-examiner error of 2 constant force probes to the reading of a conventional manual probe. 3 examiners made repeated examinations of attachment level using a modified Florida probe and a manual North Carolina probe (read to 1 mm or 0.5 mm); relative attachment level measurements were made using a Florida disk probe. One probe was used in each quadrant in 8 subjects with moderate to advanced periodontitis. Error was calculated as the mean of the absolute value of the difference between each examination, and the correlation between values at each examination calculated. Statistically-significant differences between probe type, examiners, and sites were detected using a repeated measures ANOVA accounting for the nesting within subjects. There was a significant difference in error by probe type (modified Florida probe 0.62 +/- 0.03 mm, r = 0.86; Florida stent probe 0.55 +/- 0.05 mm, r = 0.82; manual probe to 1 mm 0.39 +/- 0.02 mm, r = 0.88; manual probe to 0.5 mm 0.40 +/- 0.02 mm, r = 0.89; (p < 0.001). Significant differences were observed by examiners (p < 0.01). These data indicate that both manual and controlled-force probes can provide measurement within less than 1 mm of error; however, individual calibration of examiners remains important in the reduction of error.

  8. SPRT Calibration Uncertainties and Internal Quality Control at a Commercial SPRT Calibration Facility

    NASA Astrophysics Data System (ADS)

    Wiandt, T. J.

    2008-06-01

    The Hart Scientific Division of the Fluke Corporation operates two accredited standard platinum resistance thermometer (SPRT) calibration facilities, one at the Hart Scientific factory in Utah, USA, and the other at a service facility in Norwich, UK. The US facility is accredited through National Voluntary Laboratory Accreditation Program (NVLAP), and the UK facility is accredited through UKAS. Both provide SPRT calibrations using similar equipment and procedures, and at similar levels of uncertainty. These uncertainties are among the lowest available commercially. To achieve and maintain low uncertainties, it is required that the calibration procedures be thorough and optimized. However, to minimize customer downtime, it is also important that the instruments be calibrated in a timely manner and returned to the customer. Consequently, subjecting the instrument to repeated calibrations or extensive repeated measurements is not a viable approach. Additionally, these laboratories provide SPRT calibration services involving a wide variety of SPRT designs. These designs behave differently, yet predictably, when subjected to calibration measurements. To this end, an evaluation strategy involving both statistical process control and internal consistency measures is utilized to provide confidence in both the instrument calibration and the calibration process. This article describes the calibration facilities, procedure, uncertainty analysis, and internal quality assurance measures employed in the calibration of SPRTs. Data will be reviewed and generalities will be presented. Finally, challenges and considerations for future improvements will be discussed.

  9. Learning and cognitive fatigue trajectories in multiple sclerosis defined using a burst measurement design.

    PubMed

    Holtzer, Roee; Foley, Frederick; D'Orio, Vanessa; Spat, Jessica; Shuman, Melissa; Wang, Cuiling

    2013-10-01

    Compromised learning and cognitive fatigue are critical clinical features in multiple sclerosis. This study was designed to determine the effect of repeated exposures within and across study visits on performance measures of learning and cognitive fatigue in relapsing-remitting multiple sclerosis (RRMS). Thirty patients with RRMS and 30 controls were recruited. Using a burst measurement design (i.e. repeated assessments within and across study visits) the oral version of the Symbol Digit Modalities Test (SDMT) was administered three times during the baseline and two consecutive monthly follow-up visits for a total of nine test administrations. Learning was assessed within and across study visits whereas cognitive fatigue was assessed during the course of each test administration that was divided into three 30-second intervals. Linear mixed-effect models revealed compromised learning within (95% CI: 2.6355 to 3.9867) and across (95% CI: 1.3250 to 3.1861) visits and worse cognitive fatigue (95% CI: -2.1761 to -0.1720) in patients with RRMS compared with controls. Among patients with RRMS, worse self-rated cognitive dysfunction predicted poor learning within (95% CI: -0.1112 to -0.0020) and across (95% CI: -0.0724 to -0.0106) visits. Burst design is optimal to study learning and cognitive fatigue. This methodology, using the SDMT or other time-efficient tests as outcome measures, can be successfully implemented in longitudinal studies and clinical trials.

  10. Efficacy of a short cognitive training program in patients with multiple sclerosis

    PubMed Central

    Pérez-Martín, María Yaiza; González-Platas, Montserrat; Eguía-del Río, Pablo; Croissier-Elías, Cristina; Jiménez Sosa, Alejandro

    2017-01-01

    Background Cognitive impairment is a common feature in multiple sclerosis (MS) and may have a substantial impact on quality of life. Evidence about the effectiveness of neuropsychological rehabilitation is still limited, but current data suggest that computer-assisted cognitive training improves cognitive performance. Objective The objective of this study was to evaluate the efficacy of combined computer-assisted training supported by home-based neuropsychological training to improve attention, processing speed, memory and executive functions during 3 consecutive months. Methods In this randomized controlled study blinded for the evaluators, 62 MS patients with clinically stable disease and mild-to-moderate levels of cognitive impairment were randomized to receive a computer-assisted neuropsychological training program (n=30) or no intervention (control group [CG]; n=32). The cognitive assessment included the Brief Repeatable Battery of Neuropsychological Test. Other secondary measures included subjective cognitive impairment, anxiety and depression, fatigue and quality of life measures. Results The treatment group (TG) showed significant improvements in measures of verbal memory, working memory and phonetic fluency after intervention, and repeated measures analysis of covariance revealed a positive effect in most of the functions. The control group (CG) did not show changes. The TG showed a significant reduction in anxiety symptoms and significant improvement in quality of life. There were no improvements in fatigue levels and depressive symptoms. Conclusion Cognitive intervention with a computer-assisted training supported by home training between face-to-face sessions is a useful tool to treat patients with MS and improve functions such as verbal memory, working memory and phonetic fluency. PMID:28223806

  11. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    PubMed

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  12. Cardiopulmonary exercise testing early after stroke using feedback-controlled robotics-assisted treadmill exercise: test-retest reliability and repeatability.

    PubMed

    Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J

    2014-10-11

    Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents first evidence on reliability and repeatability for CPET in severely motor impaired individuals early after stroke using a feedback-controlled robotics-assisted treadmill. The results demonstrate good to excellent test-retest reliability and appropriate repeatability for the most important peak cardiopulmonary performance parameters. These findings have important implications for the design and implementation of cardiovascular exercise interventions in severely impaired populations. Future research needs to develop advanced control strategies to enable the true limit of functional exercise capacity to be reached and to further assess test-retest reliability and repeatability in larger samples.

  13. Lack of maintenance of gait pattern as measured by instrumental methods suggests psychogenic gait.

    PubMed

    Merello, Marcelo; Ballesteros, Diego; Rossi, Malco; Arena, Julieta; Crespo, Marcos; Cervio, Andres; Cuello Oderiz, Carolina; Rivero, Alberto; Cerquetti, Daniel; Risk, Marcelo; Balej, Jorge

    2012-01-01

    Fluctuation is a common feature of all psychogenic gait disorder (PGD) patterns. Whether this fluctuation involves only the degree of impairment or whether it affects the gait pattern itself remains an interesting question. We hypothesize that, on repeated measurements, both normal and abnormal gait may present quantitative differences while maintaining their basic underlying pattern; conversely, in psychogenic gait, the basic pattern appears not to be preserved. Using an optoelectronic system, data acquired from 19 normal subjects and 66 patients were applied to train a neural network (NN) and subsequently classify gait patterns into four different groups (normal, ataxic, spastic-paraparetic and parkinsonian). Five patients who fulfilled clinical criteria for psychogenic gait and six controls were then prospectively evaluated on two separate occasions, three months apart. Normal controls and ataxic, parkinsonian or spastic patients were correctly identified by the NN, and categorized within the corresponding groups at baseline as well as at a three-month follow-up evaluation. NN analysis showed that after three months, no PGD patient preserved the gait pattern detected at baseline, even though this finding was not clinically apparent. Modification of gait pattern detected by repeated kinematic measurement and NN analysis could suggest the presence of PGD, particularly in difficult-to-diagnose cases.

  14. An Empirical Investigation of Clicker Technology in Financial Accounting Principles

    ERIC Educational Resources Information Center

    Marshall, Leisa L.; Varnon, Anthony W.

    2012-01-01

    The effects of clicker-use and active learning classroom activities on student performance in financial accounting principles were examined. A repeated measure design was used to compare performance on four exams between a clicker group and a non-clicker group, after controlling for GPA and age. A matched-pairs t-test was used to compare the…

  15. The Effects of Methylphenidate on Various Types of Activity Level and Attention in Hyperkinetic Children

    ERIC Educational Resources Information Center

    Barkley, Russell A.

    1977-01-01

    Investigated with 18 hyperactive boys (5 to 12 years old) and 18 controls were the effects of methylphenidate on a number of objective measures of activity level and attention on three repeated occasions in four types of settings: free play, movie viewing, testing, and restricted play periods. (Author/SBH)

  16. Self-Directed Learning: To Be Aware or Not To Be Aware.

    ERIC Educational Resources Information Center

    Rhee, Kenneth S.

    2003-01-01

    Critical incident interviews and questionnaire were used to measure behavior change in 25 business students who engaged in repeated reflections on self-directed change and 20 controls. Both groups improved managerial skills. Those in the reflection group were more aware of their own change but overestimated the extent of it. (Contains 45…

  17. Spelling Instruction in Spanish: A Comparison of Self-Correction, Visual Imagery and Copying

    ERIC Educational Resources Information Center

    Gaintza, Zuriñe; Goikoetxea, Edurne

    2016-01-01

    Two randomised control experiments examined spelling outcomes in a repeated measures design (pre-test, post-tests; 1-day, 1-month follow-up, 5-month follow-up), where students learned Spanish irregular words through (1) immediate feedback using self-correction, (2) visual imagery where children imagine and represent words using movement, and (3)…

  18. An Evaluation of Second Step: What Are the Benefits for Youth With and Without Disabilities?

    ERIC Educational Resources Information Center

    Sullivan, Terri N.; Sutherland, Kevin S.; Farrell, Albert D.; Taylor, Katherine A.

    2015-01-01

    The impact of a school-based violence prevention program, Second Step, on peer victimization and aggression, and emotion regulation was evaluated among 457 sixth graders. A cluster-randomized trial was conducted with classrooms randomly assigned to intervention (n = 14) or control (n = 14) conditions. A repeated measures analysis of covariance on…

  19. [An instrument for estimating human body composition using impedance measurement].

    PubMed

    Yin, J; Peng, C

    1997-03-01

    According to the impedance feature of biological tissue, the instrument was designed at 1, 5, 10, 50, 100kHz to measure human impedance, and then to calculate human FAT, FFM, FAT%, TBW, ECW, ICW and so on. A 8031 singlechip microprocessor contacuting used as a control center in the instrument. The part of electric circuit contacuting human body in the instrument was unreally earthing. The instrument was safty, effective, repeatable, and easily manpulative. Prelimintary clinical experiment showed the results measured with the instrument could effectively reflect practical, status of human composition.

  20. Abnormal Weight and Body Mass Index in Children with Juvenile Huntington's Disease.

    PubMed

    Tereshchenko, Alexander; McHugh, Michael; Lee, Jessica K; Gonzalez-Alegre, Pedro; Crane, Kaitlin; Dawson, Jeffrey; Nopoulos, Peg

    2015-01-01

    The hallmark clinical manifestation of Huntington's disease (HD), namely lower weight and BMI has been reported in prodromal HD (PreHD) adults and also in PreHD children. Here, we aim to evaluate anthropometric measures of growth and development (height, weight, body mass index (BMI)) in a group of children, adolescents, and young adults diagnosed with Juvenile Onset Huntington's Disease (JHD). Growth measures for 18 JHD patients, documented prior to or shortly after diagnosis, were obtained through medical records. JHD growth measures were compared to a large sample (n = 274) of healthy children, as well as the Center for Disease Control (CDC) growth norms. After controlling for sex and age, the JHD subjects had no significant differences in height. However, they were an average of 10% lower than controls in weight and BMI. Using CDC norms, the JHD subjects had the same pattern of normal height but decrement in weight. Length of cytosine-adenine-guanine (CAG) repeat in the huntingtin gene was significantly correlated to measures of weight with longer CAG repeats being associated with more severe weight reduction. A subset of 4 subjects had measures that pre-dated onset of any symptom and were therefore prodromal JHD (preJHD). These subjects also had a significant decrement in BMI compared to CDC norms. Children with JHD have normal height, but significantly reduced weight and BMI, indicative of a specific deficit in body weight. As the preJHD subjects were also low in BMI, this suggests that these changes are directly due to the effect of the mutated gene on development, rather than symptom manifestation of the disease itself. Potential mechanisms of the weight decrement include energy deficiency due to mitochondrial dysfunction during development.

  1. Measurement of ulnar subtrochlear sclerosis using a percentage scale in labrador retrievers with minimal radiographic signs of periarticular osteophytosis.

    PubMed

    Smith, Thomas J; Fitzpatrick, Noel; Evans, Richard B; Pead, Mathew J

    2009-02-01

    To report the development of a measurement method for quantifying ulnar subtrochlear sclerosis (STS) in Labrador Retrievers. Prospective blinded study. Radiographs of Labrador Retrievers elbows (n=30) with minimal radiographic signs of periarticular osteophytosis. Measurement of STS as a % of the distance between 2 standardized radiographic landmarks (%STS) was developed. Mediolateral radiographic projections of flexed elbows were collected from 2 cohorts termed diseased (n=15; confirmed disease of the medial coronoid process) and control (n=15; free from clinically evident disease). Five observers blindly assessed each radiograph for radiographic technique, elbow positioning, periarticular osteophytosis, and STS, which, if present, was measured and assigned a %STS score. Intraobserver and interobserver variations in measuring STS and the ability to differentiate study cohorts were assessed using receiver operator curve (ROC) characteristics. A P-value of <.05 was considered significant. Median %STS for diseased elbows was 47% (range, 0-74%) and 0% (range, 0-62%) for control elbows. Correlations were not significantly different between each observer's assessments of %STS, with a median Spearman's P-value of .75 (range, .67-.86). All observers differentiated the 2 cohorts with "fair-good" accuracy, with a median ROC value of 0.81 (range, 0.75-0.88). Measurement of %STS in Labrador Retrievers was repeatable for each observer and repeatable between observers. A method for measuring STS allows comparison of Labrador Retrievers of different sizes, is easy to perform, and could be used to investigate the clinical significance of STS in this breed.

  2. Nimbus 7 Solar Backscatter Ultraviolet (SBUV) spectral scan solar irradiance and Earth radiance product user's guide

    NASA Technical Reports Server (NTRS)

    Schlesinger, Barry M.; Cebula, Richard P.; Heath, Donald F.; Fleig, Albert J.

    1988-01-01

    The archived tape products from the spectral scan mode measurements of solar irradiance (SUNC tapes) and Earth radiance (EARTH tapes) by the Solar Backscatter UV (SBUV) instrument aboard Nimbus 7 are described. Incoming radiation from 160 to 400 nm is measured at intervals of 0.2 nm. The scan-to-scan repeatability of the solar irradiance measurements ranges from approximately 0.5 to 1 percent longward of 280 nm, to 2 percent around 210 nm and 4 percent near 175 nm. The repeatability of the Earth radiance values ranges from 2 to 3 percent at longer wavelengths and low zenith angles to 10 percent at shorter wavelengths and high zenith angles. The tape formats are described in detail, including file structure and contents of each type of record. Catalogs of the tapes and the time period covered are provided, along with lists of the days lacking solar irradiance measurements and the days dedicated to Earth radiance measurements. The method for production of the tapes is outlined and quality control measures are described. How radiances and irradiances are derived from the raw counts, the corrections for changes in instrument sensitivity, and related uncertainties are discussed.

  3. An assessment of consistence of exhaust gas emission test results obtained under controlled NEDC conditions

    NASA Astrophysics Data System (ADS)

    Balawender, K.; Jaworski, A.; Kuszewski, H.; Lejda, K.; Ustrzycki, A.

    2016-09-01

    Measurements concerning emissions of pollutants contained in automobile combustion engine exhaust gases is of primary importance in view of their harmful impact on the natural environment. This paper presents results of tests aimed at determining exhaust gas pollutant emissions from a passenger car engine obtained under repeatable conditions on a chassis dynamometer. The test set-up was installed in a controlled climate chamber allowing to maintain the temperature conditions within the range from -20°C to +30°C. The analysis covered emissions of such components as CO, CO2, NOx, CH4, THC, and NMHC. The purpose of the study was to assess repeatability of results obtained in a number of tests performed as per NEDC test plan. The study is an introductory stage of a wider research project concerning the effect of climate conditions and fuel type on emission of pollutants contained in exhaust gases generated by automotive vehicles.

  4. A Brief Mindfulness Exercise Promotes the Correspondence Between the Implicit Affiliation Motive and Goal Setting.

    PubMed

    Strick, Madelijn; Papies, Esther K

    2017-05-01

    People often choose to pursue goals that are dissociated from their implicit motives, which jeopardizes their motivation and well-being. We hypothesized that mindfulness may attenuate this dissociation to the degree that it increases sensitivity to internal cues that signal one's implicit preferences. We tested this hypothesis with a longitudinal repeated measures experiment. In Session 1, participants' implicit affiliation motive was assessed. In Session 2, half of the participants completed a mindfulness exercise while the other half completed a control task before indicating their motivation toward pursuing affiliation and nonaffiliation goals. In Session 3, this procedure was repeated with reversed assignment to conditions. The results confirmed our hypothesis that, irrespective of the order of the conditions, the implicit affiliation motive predicted a preference to pursue affiliation goals immediately after the mindfulness exercise, but not after the control task. We discuss implications of these findings for satisfaction and well-being.

  5. A Brief Mindfulness Exercise Promotes the Correspondence Between the Implicit Affiliation Motive and Goal Setting

    PubMed Central

    Strick, Madelijn; Papies, Esther K.

    2017-01-01

    People often choose to pursue goals that are dissociated from their implicit motives, which jeopardizes their motivation and well-being. We hypothesized that mindfulness may attenuate this dissociation to the degree that it increases sensitivity to internal cues that signal one’s implicit preferences. We tested this hypothesis with a longitudinal repeated measures experiment. In Session 1, participants’ implicit affiliation motive was assessed. In Session 2, half of the participants completed a mindfulness exercise while the other half completed a control task before indicating their motivation toward pursuing affiliation and nonaffiliation goals. In Session 3, this procedure was repeated with reversed assignment to conditions. The results confirmed our hypothesis that, irrespective of the order of the conditions, the implicit affiliation motive predicted a preference to pursue affiliation goals immediately after the mindfulness exercise, but not after the control task. We discuss implications of these findings for satisfaction and well-being. PMID:28903636

  6. Preliminary analysis of STS-2 entry flight data

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A preliminary analysis of the data obtained during the entry of the STS-2 flight was completed. The stability and control derivatives from STS-2 were examined. Questions still remain throughout the flight envelope and the area below Mach 3 needs more study. With three controls operating in a high gain feedback system, it is difficult to separate the individual effects of each of the controls. Analysis of the aerothermal data shows that wing structural-temperature measurements are generally repeatable and consistent with the trajectories. The measured wing upper surface temperatures are in reasonable agreement with Dryden predictions but wing lower surface temperatures are higher than Dryden predictions. Heating and heat transfer models will be adjusted to improve the temperature prediction capability for future trajectories.

  7. Nondestructive web thickness measurement of micro-drills with an integrated laser inspection system

    NASA Astrophysics Data System (ADS)

    Chuang, Shui-Fa; Chen, Yen-Chung; Chang, Wen-Tung; Lin, Ching-Chih; Tarng, Yeong-Shin

    2010-09-01

    Nowadays, the electric and semiconductor industries use numerous micro-drills to machine micro-holes in printed circuit boards. The measurement of web thickness of micro-drills, a key parameter of micro-drill geometry influencing drill rigidity and chip-removal ability, is quite important to ensure quality control. Traditionally, inefficiently destructive measuring method is adopted by inspectors. To improve quality and efficiency of the web thickness measuring tasks, a nondestructive measuring method is required. In this paper, based on the laser micro-gauge (LMG) and laser confocal displacement meter (LCDM) techniques, a nondestructive measuring principle of web thickness of micro-drills is introduced. An integrated laser inspection system, mainly consisting of a LMG, a LCDM and a two-axis-driven micro-drill fixture device, was developed. Experiments meant to inspect web thickness of micro-drill samples with a nominal diameter of 0.25 mm were conducted to test the feasibility of the developed laser inspection system. The experimental results showed that the web thickness measurement could achieve an estimated repeatability of ± 1.6 μm and a worst repeatability of ± 7.5 μm. The developed laser inspection system, combined with the nondestructive measuring principle, was able to undertake the web thickness measuring tasks for certain micro-drills.

  8. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    ERIC Educational Resources Information Center

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  9. Comparison of low- and ultralow-dose computed tomography protocols for quantitative lung and airway assessment.

    PubMed

    Hammond, Emily; Sloan, Chelsea; Newell, John D; Sieren, Jered P; Saylor, Melissa; Vidal, Craig; Hogue, Shayna; De Stefano, Frank; Sieren, Alexa; Hoffman, Eric A; Sieren, Jessica C

    2017-09-01

    Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction, and equivalent diameter had smaller measurement differences than area and perimeter measurements. In conclusion, the use of IR with low- and ultralow-dose CT protocols with CT volume dose indices down to 0.32 mGy maintains selected quantitative parenchymal and airway measurements relevant to pulmonary disease characterization. © 2017 American Association of Physicists in Medicine.

  10. Status of a UAVSAR designed for repeat pass interferometry for deformation measurements

    NASA Technical Reports Server (NTRS)

    Hensley, Scott; Wheeler, Kevin; Sadowy, Greg; Miller, Tim; Shaffer, Scott; Muellerschoen, Ron; Jones, Cathleen; Zebker, Howard; Madsen, Soren; Paul, Rose

    2005-01-01

    NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also known as differential interferometric measurements. Differential interferometry can provide key deformation measurements, important for the scientific studies of Earthquakes and volcanoes. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The expected performance of the flight control system will constrain the flight path to be within a 10 m diameter tube about the desired flight track. The radar wilI be designed to operate on a UAV (Unpiloted Aria1 Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus buitt by Scaled Composites or on a NASA Gulfstream III. The radar design is a fully polarimetric with an 80 MHz bandwidth (2 m range resolution) and 16 km range swath. The antenna is an electronically steered along track to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. Other features supported by the antenna include an elevation monopulse option and a pulse-to-pulse resteering capability that will enable some novel modes of operation. The system will nominally operate at 45,000 ft (13800 m). The program began out as an Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

  11. Precision Attitude Determination for an Infrared Space Telescope

    NASA Technical Reports Server (NTRS)

    Benford, Dominic J.

    2008-01-01

    We have developed performance simulations for a precision attitude determination system using a focal plane star tracker on an infrared space telescope. The telescope is being designed for the Destiny mission to measure cosmologically distant supernovae as one of the candidate implementations for the Joint Dark Energy Mission. Repeat observations of the supernovae require attitude control at the level of 0.010 arcseconds (0.05 microradians) during integrations and at repeat intervals up to and over a year. While absolute accuracy is not required, the repoint precision is challenging. We have simulated the performance of a focal plane star tracker in a multidimensional parameter space, including pixel size, read noise, and readout rate. Systematic errors such as proper motion, velocity aberration, and parallax can be measured and compensated out. Our prediction is that a relative attitude determination accuracy of 0.001 to 0.002 arcseconds (0.005 to 0.010 microradians) will be achievable.

  12. Lumbopelvic Core Stabilization Exercise and Pain Modulation Among Individuals with Chronic Nonspecific Low Back Pain.

    PubMed

    Paungmali, Aatit; Joseph, Leonard H; Sitilertpisan, Patraporn; Pirunsan, Ubon; Uthaikhup, Sureeporn

    2017-11-01

    Lumbopelvic stabilization training (LPST) may provide therapeutic benefits on pain modulation in chronic nonspecific low back pain conditions. This study aimed to examine the effects of LPST on pain threshold and pain intensity in comparison with the passive automated cycling intervention and control intervention among patients with chronic nonspecific low back pain. A within-subject, repeated-measures, crossover randomized controlled design was conducted among 25 participants (7 males and 18 females) with chronic nonspecific low back pain. All the participants received 3 different types of experimental interventions, which included LPST, the passive automated cycling intervention, and the control intervention randomly, with 48 hours between the sessions. The pressure pain threshold (PPT), hot-cold pain threshold, and pain intensity were estimated before and after the interventions. Repeated-measures analysis of variance showed that LPST provided therapeutic effects as it improved the PPT beyond the placebo and control interventions (P < 0.01). The pain intensity under the LPST condition was significantly better than that under the passive automated cycling intervention and controlled intervention (P < 0.001). Heat pain threshold under the LPST condition also showed a significant trend of improvement beyond the control (P < 0.05), but no significant effects on cold pain threshold were evident. Lumbopelvic stabilization training may provide therapeutic effects by inducing pain modulation through an improvement in the pain threshold and reduction in pain intensity. LPST may be considered as part of the management programs for treatment of chronic low back pain. © 2017 World Institute of Pain.

  13. Psychological and autonomic effects of art making in college-aged students.

    PubMed

    Sandmire, David A; Rankin, Nancy E; Gorham, Sarah R; Eggleston, Daniel T; French, Cecelia A; Lodge, Emily E; Kuns, Gavin C; Grimm, David R

    2016-09-01

    Anxiety disorders comprise the most common category of mental illness among US young adults. Art making might be one method to help reduce anxiety, but the few studies investigating this have used only subjective measures of anxiety. This study employed both subjective (self-reported state anxiety from the State-Trait Anxiety Inventory) and objective (heart rate variability) measures to assess whether 30-minute periods of art making reduced anxiety in 47 first-year college students prior to their final examinations. Students participated in free-form painting, mandala coloring, clay modeling, and control sessions. Repeated-measures ANOVA with post hoc analysis revealed significantly greater pre- to post-session reductions in anxiety for all three types of art-making sessions than for the control session, as measured objectively. Measured subjectively, only free-form painting yielded a significant decrease in anxiety compared to the control session. Given the health benefits of anxiety reduction, further study is warranted to determine the duration of art making's anxiety-reducing effect.

  14. Development and validation of rt-qpcr for vesicular stomatitis virus detection (Alagoas vesiculovirus).

    PubMed

    de Oliveira, Anapolino Macedo; Fonseca, Antônio Augusto; Camargos, Marcelo Fernandes; Orzil, Lívia Maria; Laguardia-Nascimento, Mateus; Oliveira, Anna Gabriella Guimarães; Rodrigues, Jacqueline Gomes; Sales, Mariana Lázaro; de Oliveira, Tatiana Flávia Pinheiro; de Melo, Cristiano Barros

    2018-07-01

    Vesicular stomatitis is an infectious disease that occurs mainly in countries of the Western Hemisphere and affects cattle, swine and horses. The clinical symptoms in cattle and swine are similar to foot-and-mouth disease and include vesicular ulceration of the tongue and mouth. The disease requires a rapid and accurate differential diagnosis, aiming for immediate implementation of control measures. The objective of the present study was to develop and perform validation tests of multiplex RT-qPCR(s) for the detection of RNA from Alagoas vesiculovirus, considering the parameters of sensitivity and analytical specificity, analytical performance (repeatability and reproducibility criteria) and the uncertainty of the measurement. The threshold cycle values obtained in triplicate from each sample were evaluated by considering the variations between days, analysts and equipment in an analysis of variance aimed at determining the variances of repeatability and reproducibility. The results showed that RT-qPCRs had excellent sensitivity and specificity in the detection of RNA of the Alagoas vesiculovirus. The validation parameters showed low coefficients of variation and were equivalent to those found in other validation studies, indicating that the tests presented excellent repeatability and reproducibility. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Enhanced retinal responses in Huntington's disease patients.

    PubMed

    Pearl, Jocelynn R; Heath, Laura M; Bergey, Dani E; Kelly, John P; Smith, Corrie; Laurino, Mercy Y; Weiss, Avery; Price, Nathan D; LaSpada, Albert; Bird, Thomas D; Jayadev, Suman

    2017-01-01

    Huntington's disease (HD) is a fatal progressive neurodegenerative disease characterized by chorea, cognitive impairment and psychiatric symptoms. Retinal examination of HD patients as well as in HD animal models have shown evidence of retinal dysfunction. However, a detailed retinal study employing clinically available measurement tools has not been reported to date in HD. The goal of this study was to assess retinal responses measured by electroretinogram (ERG) between HD patients and controls and evaluate any correlation between ERG measurements and stage of disease. Eighteen patients and 10 controls with inclusion criteria of ages 18-70 years (average age HD subjects: 52.1 yrs and control subjects: 51.9 yrs) were recruited for the study. Subjects with previous history of retinal or ophthalmologic disease were excluded. Retinal function was examined by full-field ERG in both eyes of each subject. Amplitudes and latencies to increasing flash intensities in both light- and dark-adaptation were measured in all subjects. Statistical analyses employed generalized estimating equations, which account for repeated measures per subject. We analyzed the b-wave amplitudes of ERG response in all flash intensities and with 30 Hz flicker stimulation. We found statistically significant increased amplitudes in HD patients compared to controls at light-adapted (photopic) 24.2 and 60.9 cd.sec/m2 intensities, dark-adapted (scotopic, red flash) 0.22 cd.sec/m2 intensity, and a trend toward significance at light-adapted 30 Hz flicker. Furthermore, we found a significant increase in light-adapted ERG response from female compared to male HD patients, but no significant difference between gender amongst controls. We also noted a positive association between number of CAG repeats and ERG response at the smallest light adapted intensity (3.1 cd.sec/m2). ERG studies revealed significantly altered retinal responses at multiple flash intensities in subjects with an HD expansion allele compared to controls. Significant differences were observed with either light-adapted tests or the dark-adapted red flash which suggests that the enhanced responses in HD patients is specific to the cone photoreceptor pathway.

  16. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    PubMed Central

    Shetty, Rohit; Agrawal, Aarti; Deshmukh, Rashmi; Kaweri, Luci; Rao, Harsha L; Nagaraja, Harsha; Jayadev, Chaitra

    2017-01-01

    Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL) haze on the measurement and repeatability of pachymetry and mean keratometry (Km) of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL) underwent imaging with a scanning slit imaging device (Orbscan II) and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei). Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT) and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05) significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively). Km values were affected by haze when measured with the Pentacam HR (P < 0.05). The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively), Km values (P = 0.4 and 0.6, respectively), repeatability of TCT (P = 0.1 in both zones), and Km (P = 0.5 and 0.1, respectively) with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution. PMID:28513495

  17. Genetic variation of the androgen receptor and risk of myocardial infarction and ischemic stroke in women.

    PubMed

    Rexrode, Kathryn M; Ridker, Paul M; Hegener, Hillary H; Buring, Julie E; Manson, JoAnn E; Zee, Robert Y L

    2008-05-01

    Androgen receptors (AR) are expressed in endothelial cells and vascular smooth-muscle cells. Some studies suggest an association between AR gene variation and risk of cardiovascular disease (CVD) in men; however, the relationship has not been examined in women. Six haplotype block-tagging single nucleotide polymorphisms (rs962458, rs6152, rs1204038, rs2361634, rs1337080, rs1337082), as well as the cysteine, adenine, guanine (CAG) microsatellite in exon 1, of the AR gene were evaluated among 300 white postmenopausal women who developed CVD (158 myocardial infarctions and 142 ischemic strokes) and an equal number of matched controls within the Women's Health Study. Genotype distributions were similar between cases and controls, and genotypes were not significantly related to risk of CVD, myocardial infarctions or ischemic stroke in conditional logistic regression models. Seven common haplotypes were observed, but distributions did not differ between cases and controls nor were significant associations observed in logistic regression analysis. The median CAG repeat length was 21. In conditional logistic regression, there was no association between the number of alleles with CAG repeat length >or=21 (or >or=22) and risk of CVD, myocardial infarctions or ischemic stroke. No association between AR genetic variation, as measured by haplotype-tagging single nucleotide polymorphisms and CAG repeat number, and risk of CVD was observed in women.

  18. SEM-based overlay measurement between via patterns and buried M1 patterns using high-voltage SEM

    NASA Astrophysics Data System (ADS)

    Hasumi, Kazuhisa; Inoue, Osamu; Okagawa, Yutaka; Shao, Chuanyu; Leray, Philippe; Halder, Sandip; Lorusso, Gian; Jehoul, Christiane

    2017-03-01

    The miniaturization of semiconductors continues, importance of overlay measurement is increasing. We measured overlay with analysis SEM called Miracle Eye which can output ultrahigh acceleration voltage in 1998. Meanwhile, since 2006, we have been working on SEM based overlay measurement and developed overlay measurement function of the same layer using CD-SEM. Then, we evaluated overlay of the same layer pattern after etching. This time, in order to measure overlay after lithography, we evaluated the see-through overlay using high voltage SEM CV5000 released in October 2016. In collaboration between imec and Hitachi High-Technologies, we evaluated repeatability, TIS of SEM-OVL as well as correlation between SEM-OVL and Opt-OVL in the M1@ADI and V0@ADI process. Repeatability and TIS results are reasonable and SEM-OVL has good correlation with Opt-OVL. By overlay measurement using CV 5000, we got the following conclusions. (1)SEM_OVL results of both M1 and V0 at ADI show good correlation to OPT_OVL. (2)High voltage SEM can prove the measurement capability of a small pattern(Less than 1 2um) like device that can be placed in-die area. (3)"In-die SEM based overlay" shows possibility for high order control of scanner

  19. [Nitrous compound content in the tissues of the cerebral hemispheres and cerebellum of rats after a flight on the Kosmos-1129 biosatellite].

    PubMed

    Kurkina, L M; Tigranian, R A

    1982-01-01

    The content of ammonia, glutamine, urea, glutamic acid, aspartic acid, and GABA was measured to study nitrogen metabolism. Soon after recovery (6-10 hours after recovery) the content of the above compounds in brain tissues increased, except for GABA whose content decreased. Similar but more marked changes were seen in the brain of control rats exposed to a repeated immobilization stress-effect. These changes were still greater in the flight rats exposed to a repeated immobilization stress-effect postflight. It is suggested that the postflight changes of the above parameters of nitrogen metabolism are induced by stress-agents inherent in space flight and recovery.

  20. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    PubMed

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  1. Effects of immunization with natural and recombinant lysine decarboxylase on canine gingivitis development.

    PubMed

    Peters, Jennifer L; DeMars, Paul L; Collins, Lindsay M; Stoner, Julie A; Matsumoto, Hiroyuki; Komori, Naoka; Singh, Anil; Feasley, Christa L; Haddock, James A; Levine, Martin

    2012-10-19

    Periodontal disease, gingival inflammation (gingivitis) and periodontal attachment loss (periodontitis), causes tooth loss and susceptibility to chronic inflammation. Professionally scaling and cleaning the teeth regularly controls the disease, but is expensive in companion animals. Eikenella corrodens is common in canine oral cavities where it is a source of lysine decarboxylase (LDC). In human dental biofilms (plaques), LDC converts lysine to cadaverine and impairs the gingival epithelial barrier to bacteria. LDC vaccination may therefore retard gingivitis development. Year-old beagle dogs provided blood samples, and had weight and clinical measurements (biofilm and gingivitis) recorded. After scaling and cleaning, two dogs were immunized subcutaneously with 0.2mg native LDC from E. corrodens and 2 sets of four dogs with 0.2mg recombinant LDC purified from Escherichia coli. A third set of 4 dogs was immunized intranasally. Rehydragel(®), Emulsigen(®), Polygen™ or Carbigen™ were used as adjuvant. Four additional pairs of dogs were sham-immunized with each adjuvant alone (controls). Immunizations were repeated twice, 3 weeks apart, and clinical measurements were obtained after another 2 weeks, when the teeth were scaled and cleaned again. Tooth brushing was then stopped and the diet was changed from hard to soft chow. Clinical measurements were repeated after 1, 2, 3, 4, 6 and 8 weeks. Compared with sham-immunized dogs, gingivitis was reduced over all 8 weeks of soft diet after subcutaneous immunization with native LDC, or after intranasal immunization with recombinant LDC in Carbigen™, but for only 6 of the 8 weeks after subcutaneous immunization with recombinant LDC in Emulsigen(®) (repeated measures ANOVA). Subcutaneous vaccination induced a strong serum IgG antibody response that decreased during the soft diet period, whereas intranasal immunization induced a weak serum IgA antibody response that did not decrease. Immunization with recombinant LDC may provide protection from gingivitis if procedures are optimized. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    PubMed Central

    da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho

    2011-01-01

    Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997

  3. Repeat variation in the human PER2 gene as a new genetic marker associated with cocaine addiction and brain dopamine D2 receptor availability

    PubMed Central

    Shumay, E; Fowler, J S; Wang, G-J; Logan, J; Alia-Klein, N; Goldstein, R Z; Maloney, T; Wong, C; Volkow, N D

    2012-01-01

    Low dopamine D2 receptor (D2R) levels in the striatum are consistently reported in cocaine abusers; inter-individual variations in the degree of the decrease suggest a modulating effect of genetic makeup on vulnerability to addiction. The PER2 (Period 2) gene belongs to the clock genes family of circadian regulators; circadian oscillations of PER2 expression in the striatum was modulated by dopamine through D2Rs. Aberrant periodicity of PER2 contributes to the incidence and severity of various brain disorders, including drug addiction. Here we report a newly identified variable number tandem repeat (VNTR) polymorphism in the human PER2 gene (VNTR in the third intron). We found significant differences in the VNTR alleles prevalence across ethnic groups so that the major allele (4 repeats (4R)) is over-represented in non-African population (4R homozygosity is 88%), but not in African Americans (homozygosity 51%). We also detected a biased PER2 genotype distribution among healthy controls and cocaine-addicted individuals. In African Americans, the proportion of 4R/three repeat (3R) carriers in healthy controls is much lower than that in cocaine abusers (23% vs 39%, P=0.004), whereas among non-Africans most 3R/4R heterozygotes are healthy controls (10.5% vs 2.5%, P=0.04). Analysis of striatal D2R availability measured with positron emission tomography and [11C]raclopride revealed higher levels of D2R in carriers of 4R/4R genotype (P<0.01). Taken together, these results provide preliminary evidence for the role of the PER2 gene in regulating striatal D2R availability in the human brain and in vulnerability for cocaine addiction. PMID:22832851

  4. Whole-animal metabolic rate is a repeatable trait: a meta-analysis.

    PubMed

    Nespolo, Roberto F; Franco, Marcela

    2007-06-01

    Repeatability studies are gaining considerable interest among physiological ecologists, particularly in traits affected by high environmental/residual variance, such as whole-animal metabolic rate (MR). The original definition of repeatability, known as the intraclass correlation coefficient, is computed from the components of variance obtained in a one-way ANOVA on several individuals from which two or more measurements are performed. An alternative estimation of repeatability, popular among physiological ecologists, is the Pearson product-moment correlation between two consecutive measurements. However, despite the more than 30 studies reporting repeatability of MR, so far there is not a definite synthesis indicating: (1) whether repeatability changes in different types of animals; (2) whether some kinds of metabolism are more repeatable than others; and most important, (3) whether metabolic rate is significantly repeatable. We performed a meta-analysis to address these questions, as well as to explore the historical trend in repeatability studies. Our results show that metabolic rate is significantly repeatable and its effect size is not statistically affected by any of the mentioned factors (i.e. repeatability of MR does not change in different species, type of metabolism, time between measurements, and number of individuals). The cumulative meta-analysis revealed that repeatability studies in MR have already reached an asymptotical effect size with no further change either in its magnitude and/or variance (i.e. additional studies will not contribute significantly to the estimator). There was no evidence of strong publication bias.

  5. SCA8 Repeat Expansion: Large CTA/CTG Repeat Alleles Are More Common in Ataxic Patients, Including Those with SCA6

    PubMed Central

    Izumi, Yuishin; Maruyama, Hirofumi; Oda, Masaya; Morino, Hiroyuki; Okada, Takayuki; Ito, Hidefumi; Sasaki, Iwao; Tanaka, Hiroyasu; Komure, Osamu; Udaka, Fukashi; Nakamura, Shigenobu; Kawakami, Hideshi

    2003-01-01

    We analyzed the SCA8 CTA/CTG repeat in a large group of Japanese subjects. The frequency of large alleles (85–399 CTA/CTG repeats) was 1.9% in spinocerebellar ataxia (SCA), 0.4% in Parkinson disease, 0.3% in Alzheimer disease, and 0% in a healthy control group; the frequency was significantly higher in the group with SCA than in the control group. Homozygotes for large alleles were observed only in the group with SCA. In five patients with SCA from two families, a large SCA8 CTA/CTG repeat and a large SCA6 CAG repeat coexisted. Age at onset was correlated with SCA8 repeats rather than SCA6 repeats in these five patients. In one of these families, at least one patient showed only a large SCA8 CTA/CTG repeat allele, with no large SCA6 CAG repeat allele. We speculate that the presence of a large SCA8 CTA/CTG repeat allele influences the function of channels such as α1A-voltage–dependent calcium channel through changing or aberrant splicing, resulting in the development of cerebellar ataxia, especially in homozygous patients. PMID:12545428

  6. SCA8 repeat expansion: large CTA/CTG repeat alleles are more common in ataxic patients, including those with SCA6.

    PubMed

    Izumi, Yuishin; Maruyama, Hirofumi; Oda, Masaya; Morino, Hiroyuki; Okada, Takayuki; Ito, Hidefumi; Sasaki, Iwao; Tanaka, Hiroyasu; Komure, Osamu; Udaka, Fukashi; Nakamura, Shigenobu; Kawakami, Hideshi

    2003-03-01

    We analyzed the SCA8 CTA/CTG repeat in a large group of Japanese subjects. The frequency of large alleles (85-399 CTA/CTG repeats) was 1.9% in spinocerebellar ataxia (SCA), 0.4% in Parkinson disease, 0.3% in Alzheimer disease, and 0% in a healthy control group; the frequency was significantly higher in the group with SCA than in the control group. Homozygotes for large alleles were observed only in the group with SCA. In five patients with SCA from two families, a large SCA8 CTA/CTG repeat and a large SCA6 CAG repeat coexisted. Age at onset was correlated with SCA8 repeats rather than SCA6 repeats in these five patients. In one of these families, at least one patient showed only a large SCA8 CTA/CTG repeat allele, with no large SCA6 CAG repeat allele. We speculate that the presence of a large SCA8 CTA/CTG repeat allele influences the function of channels such as alpha(1A)-voltage-dependent calcium channel through changing or aberrant splicing, resulting in the development of cerebellar ataxia, especially in homozygous patients.

  7. Androgen receptor CAG repeat polymorphisms in canine prostate cancer.

    PubMed

    Lai, C-L; L'Eplattenier, H; van den Ham, R; Verseijden, F; Jagtenberg, A; Mol, J A; Teske, E

    2008-01-01

    Relatively shorter lengths of the polymorphic polyglutamine repeat-1 of the androgen receptor (AR) have been associated with an increased risk of prostate cancer (PC) in humans. In the dog, there are 2 polymorphic CAG repeat (CAGr) regions. To investigate the relationship of CAGr length of the canine AR-gene and the development of PC. Thirty-two dogs with PC and 172 control dogs were used. DNA was extracted from blood. Both CAG repeats were amplified by polymerase chain reaction (PCR) and PCR products were sequenced. In dogs with PC, CAG-1 repeat length was shorter (P = .001) by an increased proportion of 10 repeats (P = .011) and no 12 repeats (P = .0017) than in the control dogs. No significant changes were found in CAG-3 length distribution. CAG-1 and CAG-3 polymorphisms proved not to be in linkage disequilibrium. Breed difference in allelic distribution was found in the control group. Of the prostate-disease sensitive breeds, a high percentage (64.5%) of the shortest haplotype 10/11 was found in the Doberman, whereas Beagles and German Pointers had higher haplotype 12/11 (47.1 and 50%). Bernese Mountain dogs and Bouvier dogs both shared a high percentage of 11 CAG-1 repeats and 13 CAG-3 repeats. Differences in (combined) allelic distributions among breeds were not significant. In this preliminary study, short CAG-1 repeats in the AR-gene were associated with an increased risk of developing canine PC. Although breed-specific differences in allelic distribution of CAG-1 and CAG-3 repeats were found, these could not be related to PC risk.

  8. Effects of High-Intensity Training on Anaerobic and Aerobic Contributions to Total Energy Release During Repeated Supramaximal Exercise in Obese Adults.

    PubMed

    Jabbour, Georges; Iancu, Horia-Daniel; Paulin, Anne

    Studying relative anaerobic and aerobic metabolism contributions to total energy release during exercise may be valuable in understanding exercise energetic demands and the energetic adaptations that occur in response to acute or chronic exercise in obese adults. The aim of the present study is to evaluate the effects of 6 weeks of high-intensity training (HIT) on relative anaerobic and aerobic contributions to total energy release and on peak power output during repeated supramaximal cycling exercises (SCE) in obese adults. Twenty-four obese adults (body mass index = ± 33 kg.m -2 ) were randomized into a control group ( n  = 12) and an HIT group ( n  = 12). Accumulated oxygen deficits (ml.min -1 ) and anaerobic and aerobic contributions (%) were measured in all groups before and after training via repeated SCE. In addition, the peak power output performed during SCE was determined using the force-velocity test. Before HIT, anaerobic contributions to repeated SCE did not differ between the groups and decreased significantly during the third and fourth repetitions. After HIT, anaerobic contributions increased significantly in the HIT group (+11 %, p  < 0.01) and were significantly higher than those of the control group ( p  < 0.01). Moreover, the peak power obtained during SCE increased significantly in the HIT group (+110 W.kg -1 , p  < 0.01) and correlated positively with increases in anaerobic contributions ( r  = 0.9, p  < 0.01). In obese adults, HIT increased anaerobic contributions to energy release which were associated with peak power enhancement in response to repeated SCE. Consequently, HIT may be an appropriate approach for improving energy contributions and muscle power among obese adults.

  9. New method for remote and repeatable monitoring of intraocular pressure variations.

    PubMed

    Margalit, Israel; Beiderman, Yevgeny; Skaat, Alon; Rosenfeld, Elkanah; Belkin, Michael; Tornow, Ralf-Peter; Mico, Vicente; Garcia, Javier; Zalevsky, Zeev

    2014-02-01

    We present initial steps toward a new measurement device enabling high-precision, noncontact remote and repeatable monitoring of intraocular pressure (IOP)-based on an innovative measurement principle. Using only a camera and a laser source, the device measures IOP by tracking the secondary speckle pattern trajectories produced by the reflection of an illuminating laser beam from the iris or the sclera. The device was tested on rabbit eyes using two different methods to modify IOP: via an infusion bag and via mechanical pressure. In both cases, the eyes were stimulated with increasing and decreasing ramps of the IOP. As IOP variations changed the speckle distributions reflected back from the eye, data were recorded under various optical configurations to define and optimize the best experimental configuration for the IOP extraction. The association between the data provided by our proposed device and that resulting from controlled modification of the IOP was assessed, revealing high correlation (R2=0.98) and sensitivity and providing a high-precision measurement (5% estimated error) for the best experimental configuration. Future steps will be directed toward applying the proposed measurement principle in clinical trials for monitoring IOP with human subjects.

  10. Evaluation of electrolytic tilt sensors for measuring model angle of attack in wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Wong, Douglas T.

    1992-01-01

    The results of a laboratory evaluation of electrolytic tilt sensors as potential candidates for measuring model attitude or angle of attack in wind tunnel tests are presented. The performance of eight electrolytic tilt sensors was compared with that of typical servo accelerometers used for angle-of-attack measurements. The areas evaluated included linearity, hysteresis, repeatability, temperature characteristics, roll-on-pitch interaction, sensitivity to lead-wire resistance, step response time, and rectification. Among the sensors being evaluated, the Spectron model RG-37 electrolytic tilt sensors have the highest overall accuracy in terms of linearity, hysteresis, repeatability, temperature sensitivity, and roll sensitivity. A comparison of the sensors with the servo accelerometers revealed that the accuracy of the RG-37 sensors was on the average about one order of magnitude worse. Even though a comparison indicates that the cost of each tilt sensor is about one-third the cost of each servo accelerometer, the sensors are considered unsuitable for angle-of-attack measurements. However, the potential exists for other applications such as wind tunnel wall-attitude measurements where the errors resulting from roll interaction, vibration, and response time are less and sensor temperature can be controlled.

  11. Rule-of-thumb adjustment of sample sizes to accommodate dropouts in a two-stage analysis of repeated measurements.

    PubMed

    Overall, John E; Tonidandel, Scott; Starbuck, Robert R

    2006-01-01

    Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.

  12. Bridging the Research-to-Practice Gap in Education: A Software-Mediated Approach for Improving Classroom Instruction

    ERIC Educational Resources Information Center

    Weston, Mark E.; Bain, Alan

    2015-01-01

    This study reports findings from a matched-comparison, repeated-measure for intact groups design of the mediating effect of a suite of software on the quality of classroom instruction provided to students by teachers. The quality of instruction provided by teachers in the treatment and control groups was documented via observations that were…

  13. A highly efficient machine planting system for forestry research plantations—the Wright-MSU method

    Treesearch

    James R. McKenna; Oriana Rueda-Krauss; Brian Beheler

    2011-01-01

    For forestry research purposes, grid planting with uniform tree spacing is superior to planting with nonuniform spacing because it controls density across the plantation and facilitates accurate repeat measurements. The ability to cross-check tree positions in a grid-type plantation avoids problems associated with dead or missing trees and increases the efficiency and...

  14. The Impact of Topic Interest, L2 Proficiency, and Gender on EFL Incidental Vocabulary Acquisition through Reading

    ERIC Educational Resources Information Center

    Lee, Sunjung; Pulido, Diana

    2017-01-01

    This study investigated the impact of topic interest, alongside L2 proficiency and gender, on L2 vocabulary acquisition through reading. A repeated-measures design was used with 135 Korean EFL students. Control variables included topic familiarity, prior target-word knowledge, and target-word difficulty (word length, class, and concreteness).…

  15. Multidimensional Latent Markov Models in a Developmental Study of Inhibitory Control and Attentional Flexibility in Early Childhood

    ERIC Educational Resources Information Center

    Bartolucci, Francesco; Solis-Trapala, Ivonne L.

    2010-01-01

    We demonstrate the use of a multidimensional extension of the latent Markov model to analyse data from studies with repeated binary responses in developmental psychology. In particular, we consider an experiment based on a battery of tests which was administered to pre-school children, at three time periods, in order to measure their inhibitory…

  16. Distribution of Reading Time When Questions are Asked about a Restricted Category of Text Information. Technical Report No. 83.

    ERIC Educational Resources Information Center

    Reynolds, Ralph E.; And Others

    Forty-three college students read a specially prepared text either with or without inserted questions. The text and the questions were presented on a computer terminal to allow measurement of reading times on short segments of material. Question groups performed better, relative to controls, on posttest items that repeated inserted questions and…

  17. Reproducibility of UAV-based earth topography reconstructions based on Structure-from-Motion algorithms

    NASA Astrophysics Data System (ADS)

    Clapuyt, Francois; Vanacker, Veerle; Van Oost, Kristof

    2016-05-01

    Combination of UAV-based aerial pictures and Structure-from-Motion (SfM) algorithm provides an efficient, low-cost and rapid framework for remote sensing and monitoring of dynamic natural environments. This methodology is particularly suitable for repeated topographic surveys in remote or poorly accessible areas. However, temporal analysis of landform topography requires high accuracy of measurements and reproducibility of the methodology as differencing of digital surface models leads to error propagation. In order to assess the repeatability of the SfM technique, we surveyed a study area characterized by gentle topography with an UAV platform equipped with a standard reflex camera, and varied the focal length of the camera and location of georeferencing targets between flights. Comparison of different SfM-derived topography datasets shows that precision of measurements is in the order of centimetres for identical replications which highlights the excellent performance of the SfM workflow, all parameters being equal. The precision is one order of magnitude higher for 3D topographic reconstructions involving independent sets of ground control points, which results from the fact that the accuracy of the localisation of ground control points strongly propagates into final results.

  18. Comparison of heat generated by alumina-toughened zirconia and stainless steel burs for implant placement.

    PubMed

    Pires, Luis Fernando S; Tandler, Bernard; Bissada, Nabil; Duarte, Sillas

    2012-01-01

    In current practice, two types of burs are typically used: stainless steel (SS) and alumina-toughened zirconia (ATZ). The present study evaluated the durability of these two burs in relation to osteotomy creation for implant placement. In addition, the effects of the two types of burs on a bone model were examined. SS and ATZ burs were compared under controlled conditions in a swine rib osteotomy. The heat generated and time necessary for perforation were measured and analyzed with repeated-measures one-way analysis of variance. The burs and bone samples were evaluated using scanning electron microscopy. New ATZ and SS burs showed greater bone disruption compared to burs that had been used 80 times. Brand new burs of either material showed small manufacturing defects, which increased in number with use. No clinically or statistically significant differences were found between burs with respect to temperature and time for perforation. SS and ATZ burs can be used several times for implant site preparation under controlled conditions without reaching a temperature that is harmful to the bone. Both burs wear under repeated use, but not to an excessive degree. The duller burs produced smoother perforations than did the new ones.

  19. No neurochemical evidence of brain injury after blast overpressure by repeated explosions or firing heavy weapons.

    PubMed

    Blennow, K; Jonsson, M; Andreasen, N; Rosengren, L; Wallin, A; Hellström, P A; Zetterberg, H

    2011-04-01

    Psychiatric and neurological symptoms are common among soldiers exposed to blast without suffering a direct head injury. It is not known whether such symptoms are direct consequences of blast overpressure. To examine if repeated detonating explosions or firing if of heavy weapons is associated with neurochemical evidence of brain damage. Three controlled experimental studies. In the first, army officers were exposed to repeated firing of a FH77B howitzer or a bazooka. Cerebrospinal fluid (CSF) was taken post-exposure to measure biomarkers for brain damage. In the second, officers were exposed for up to 150 blasts by firing a bazooka, and in the third to 100 charges of detonating explosives of 180 dB. Serial serum samples were taken after exposure. Results were compared with a control group consisting of 19 unexposed age-matched healthy volunteers. The CSF biomarkers for neuronal/axonal damage (tau and neurofilament protein), glial cell injury (GFAP and S-100b), blood-brain barrier damage (CSF/serum albumin ratio) and hemorrhages (hemoglobin and bilirubin) and the serum GFAP and S-100b showed normal and stable levels in all exposed officers. Repeated exposure to high-impact blast does not result in any neurochemical evidence of brain damage. These findings are of importance for soldiers regularly exposed to high-impact blast when firing artillery shells or other types of heavy weapons. © 2010 John Wiley & Sons A/S.

  20. On the Automatic Decellularisation of Porcine Aortae: A Repeatability Study Using a Non-Enzymatic Approach.

    PubMed

    O'Connor Mooney, Rory; Davis, Niall Francis; Hoey, David; Hogan, Lisa; McGloughlin, Timothy M; Walsh, Michael T

    2016-01-01

    To investigate the repeatability of automatic decellularisation of porcine aortae using a non-enzymatic approach, addressing current limitations associated with other automatic decellularisation processes. Individual porcine aortae (n = 3) were resected and every third segment (n = 4) was allocated to one of three different groups: a control or a manually or automatically decellularised group. Manual and automatic decellularisation was performed using Triton X-100 (2% v/v) and sodium deoxycholate. Protein preservation and the elimination of a galactosyl-α(1,3)galactose (GAL) epitope were measured using immunohistochemistry and protein binding assays. The presence of residual DNA was determined with gel electrophoresis and spectrophotometry. Scaffold integrity was characterised with scanning electron microscopy and uni-axial tensile testing. Manual and automatic results were compared to one another, to control groups and to current gold standards. The results were comparable to those of current gold standard decellularisation techniques. Successful repeatability was achieved, both manually and automatically, with little effect on mechanical characteristics. Complete acellularity was not confirmed in either decellularisation group. Protein preservation was consistent in both the manually and automatically decellularised groups and between each individual aorta. Elimination of GAL was not achieved. Repeatable automatic decellularisation of porcine aortae is feasible using a Triton X-100-sodium deoxycholate protocol. Protein preservation was satisfactory; however, gold standard thresholds for permissible residual DNA levels were not achieved. Future research will focus on addressing this issue by optimisation of the existing protocol for thick tissues. © 2016 S. Karger AG, Basel.

  1. Accuracy, repeatability, and reproducibility of Artemis very high-frequency digital ultrasound arc-scan lateral dimension measurements

    PubMed Central

    Reinstein, Dan Z.; Archer, Timothy J.; Silverman, Ronald H.; Coleman, D. Jackson

    2008-01-01

    Purpose To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. Setting London Vision Clinic, London, United Kingdom. Methods A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. Results The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. Conclusion The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment. PMID:17081860

  2. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  3. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    PubMed Central

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  4. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    PubMed

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  5. Overcoming the rate-distance limit of quantum key distribution without quantum repeaters.

    PubMed

    Lucamarini, M; Yuan, Z L; Dynes, J F; Shields, A J

    2018-05-01

    Quantum key distribution (QKD) 1,2 allows two distant parties to share encryption keys with security based on physical laws. Experimentally, QKD has been implemented via optical means, achieving key rates of 1.26 megabits per second over 50 kilometres of standard optical fibre 3 and of 1.16 bits per hour over 404 kilometres of ultralow-loss fibre in a measurement-device-independent configuration 4 . Increasing the bit rate and range of QKD is a formidable, but important, challenge. A related target, which is currently considered to be unfeasible without quantum repeaters 5-7 , is overcoming the fundamental rate-distance limit of QKD 8 . This limit defines the maximum possible secret key rate that two parties can distil at a given distance using QKD and is quantified by the secret-key capacity of the quantum channel 9 that connects the parties. Here we introduce an alternative scheme for QKD whereby pairs of phase-randomized optical fields are first generated at two distant locations and then combined at a central measuring station. Fields imparted with the same random phase are 'twins' and can be used to distil a quantum key. The key rate of this twin-field QKD exhibits the same dependence on distance as does a quantum repeater, scaling with the square-root of the channel transmittance, irrespective of who (malicious or otherwise) is in control of the measuring station. However, unlike schemes that involve quantum repeaters, ours is feasible with current technology and presents manageable levels of noise even on 550 kilometres of standard optical fibre. This scheme is a promising step towards overcoming the rate-distance limit of QKD and greatly extending the range of secure quantum communications.

  6. Genetic variants in IGF-I, IGF-II, IGFBP-3, and adiponectin genes and colon cancer risk in African Americans and Whites

    PubMed Central

    Keku, Temitope O.; Vidal, Adriana; Oliver, Shannon; Hoyo, Catherine; Hall, Ingrid J.; Omofoye, Seun; McDoom, Maya; Worley, Kendra; Galanko, Joseph; Sandler, Robert S.; Millikan, Robert

    2014-01-01

    Purpose Evaluating genetic susceptibility may clarify effects of known environmental factors and also identify individuals at high risk. We evaluated the association of four insulin-related pathway gene polymorphisms in insulin-like growth factor-1 (IGF-I) (CA)n repeat, insulin-like growth factor-2 (IGF-II) (rs680), insulin-like growth factor binding protein-3 (IGFBP-3) (rs2854744), and adiponectin (APM1 rs1501299) with colon cancer risk, as well as relationships with circulating IGF-I, IGF-II, IGFBP-3, and C-peptide in a population-based study. Methods Participants were African Americans (231cases, 306 controls) and Whites (297 cases, 530 controls). Consenting subjects provided blood specimens, and lifestyle/diet information. Genotyping for all genes except IGF-I was performed by the 5′-exonuclease (Taqman) assay. The IGF-I (CA)n repeat was assayed by PCR, and fragment analysis. Circulating proteins were measured by enzyme immunoassays. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated by logistic regression. Results The IGF-I (CA)19 repeat was higher in White controls (50%) than African American controls (31%). Whites homozygous for the IGF-I (CA)19 repeat had a nearly two fold increase in risk of colon cancer (OR=1.77; 95%CI=1.15–2.73), but not African Americans (OR= 0.73, 95%CI 0.50–1.51). We observed an inverse association between the IGF-II Apa1 A-variant and colon cancer risk (OR= 0.49, 95%CI 0.28–0.88) in Whites only. Carrying the IGFBP-3 variant alleles was associated with lower IGFBP-3 protein levels, a difference most pronounced in Whites (p- trend < 0.05). Conclusions These results support an association between insulin pathway-related genes and elevated colon cancer risk in Whites but not in African Americans. PMID:22565227

  7. Genetic variants in IGF-I, IGF-II, IGFBP-3, and adiponectin genes and colon cancer risk in African Americans and Whites.

    PubMed

    Keku, Temitope O; Vidal, Adriana; Oliver, Shannon; Hoyo, Catherine; Hall, Ingrid J; Omofoye, Oluwaseun; McDoom, Maya; Worley, Kendra; Galanko, Joseph; Sandler, Robert S; Millikan, Robert

    2012-07-01

    Evaluating genetic susceptibility may clarify effects of known environmental factors and also identify individuals at high risk. We evaluated the association of four insulin-related pathway gene polymorphisms in insulin-like growth factor-1 (IGF-I) (CA)( n ) repeat, insulin-like growth factor-2 (IGF-II) (rs680), insulin-like growth factor-binding protein-3 (IGFBP-3) (rs2854744), and adiponectin (APM1 rs1501299) with colon cancer risk, as well as relationships with circulating IGF-I, IGF-II, IGFBP-3, and C-peptide in a population-based study. Participants were African Americans (231 cases and 306 controls) and Whites (297 cases, 530 controls). Consenting subjects provided blood specimens and lifestyle/diet information. Genotyping for all genes except IGF-I was performed by the 5'-exonuclease (Taqman) assay. The IGF-I (CA)(n) repeat was assayed by PCR and fragment analysis. Circulating proteins were measured by enzyme immunoassays. Odds ratios (ORs) and 95 % confidence intervals (CIs) were calculated by logistic regression. The IGF-I (CA)( 19 ) repeat was higher in White controls (50 %) than African American controls (31 %). Whites homozygous for the IGF-I (CA)(19) repeat had a nearly twofold increase in risk of colon cancer (OR = 1.77; 95 % CI = 1.15-2.73), but not African Americans (OR = 0.73, 95 % CI 0.50-1.51). We observed an inverse association between the IGF-II Apa1 A-variant and colon cancer risk (OR = 0.49, 95 % CI 0.28-0.88) in Whites only. Carrying the IGFBP-3 variant alleles was associated with lower IGFBP-3 protein levels, a difference most pronounced in Whites (p-trend <0.05). These results support an association between insulin pathway-related genes and elevated colon cancer risk in Whites but not in African Americans.

  8. Test-retest repeatability of myocardial oxidative metabolism and efficiency using standalone dynamic 11C-acetate PET and multimodality approaches in healthy controls.

    PubMed

    Hansson, Nils Henrik; Harms, Hendrik Johannes; Kim, Won Yong; Nielsen, Roni; Tolbod, Lars P; Frøkiær, Jørgen; Bouchelouche, Kirsten; Poulsen, Steen Hvitfeldt; Wiggers, Henrik; Parner, Erik Thorlund; Sörensen, Jens

    2018-05-31

    Myocardial efficiency measured by 11 C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using 11 C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEE CMR , MEE Echo , and MEE PET values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P < .001. WMI CMR , WMI Echo , and WMI PET values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m 2  × 10 6 , respectively, P = .45. Repeatability for MEE CMR was superior compared with MEE Echo but did not differ significantly compared with MEE PET (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMI CMR , WMI Echo , and WMI PET were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). Non-invasive measurements of MEE using 11 C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.

  9. Comparison of three types of full-body compression garments on throwing and repeat-sprint performance in cricket players.

    PubMed

    Duffield, Rob; Portus, Marc

    2007-07-01

    To compare the effects of three types of full-body compression garments (Skins, Adidas and Under Armour) on repeat-sprint and throwing performance in cricket players. Following familiarisation, 10 male cricket players performed four randomised exercise sessions (3 garments and a control). Each session involved a 30 min repeat-sprint exercise protocol comprising 20 m sprints every minute, separated by submaximal exercise. Throwing tests included a pre-exercise and a postexercise maximal distance test and accuracy throwing tests. During each session, measures of heart rate, skin temperature, change in body mass, rate of perceived exertion and perceived muscle soreness were recorded. Capillary blood samples were analysed before and after exercise for lactate, pH, O(2) saturation and O(2) partial pressure, and 24 h after exercise for creatine kinase (CK). Ratings of perceived muscle soreness were also obtained 24 h after exercise. No significant differences (p>0.05) were evident in repeat-sprint performance (10 m, 20 m time or total submaximal distance covered) or throwing performance (maximum distance or accuracy). No significant differences (p>0.05) were observed in heart rate, body mass change or blood measures during exercise. Significant differences (p<0.05) were observed by way of higher mean skin temperature, lower 24 h postexercise CK values and lower 24 h postexercise ratings of muscle soreness when wearing compression garments. Analysis between respective brands of compression garments revealed no statistical differences (p>0.05). No benefit was noted when wearing compression garments for repeat-sprint or throwing performance; however, the use of the garments as a recovery tool, when worn after exercise, may be beneficial to reduce postexercise trauma and perceived muscle soreness.

  10. Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer.

    PubMed

    Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei

    2015-10-01

    To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Role of Androgen Receptor CAG Repeat Polymorphism and X-Inactivation in the Manifestation of Recurrent Spontaneous Abortions in Indian Women

    PubMed Central

    Aruna, Meka; Dasgupta, Shilpi; Sirisha, Pisapati V. S.; Andal Bhaskar, Sadaranga; Tarakeswari, Surapaneni; Singh, Lalji; Reddy, B. Mohan

    2011-01-01

    The aim of the present study was to investigate the role of CAG repeat polymorphism and X-chromosome Inactivation (XCI) pattern in Recurrent Spontaneous Abortions among Indian women which has not been hitherto explored. 117 RSA cases and 224 Controls were included in the study. Cases were recruited from two different hospitals - Lakshmi Fertility Clinic, Nellore and Fernandez Maternity Hospital, Hyderabad. Controls were roughly matched for age, ethnicity and socioeconomic status. The CAG repeats of the Androgen Receptor gene were genotyped using a PCR-based assay and were analysed using the GeneMapper software to determine the CAG repeat length. XCI analysis was also carried out to assess the inactivation percentages. RSA cases had a significantly greater frequency of allele sizes in the polymorphic range above 19 repeats (p = 0.006), which is the median value of the controls, and in the biallelic mean range above 21 repeats (p = 0.002). We found no evidence of abnormal incidence of skewed X-inactivation. We conclude that longer CAG repeat lengths are associated with increased odds for RSA with statistical power estimated to be ∼90%. PMID:21423805

  12. Assessment of repeatability of a wireless, inertial sensor-based lameness evaluation system for horses.

    PubMed

    Keegan, Kevin G; Kramer, Joanne; Yonezawa, Yoshiharu; Maki, Hiromitchi; Pai, P Frank; Dent, Eric V; Kellerman, Thomas E; Wilson, David A; Reed, Shannon K

    2011-09-01

    To determine repeatability of a wireless, inertial sensor-based lameness evaluation system in horses. 236 horses. Horses were from 2 to 29 years of age and of various breeds and lameness disposition. All horses were instrumented with a wireless, inertial sensor-based motion analysis system on the head (accelerometer), pelvis (midline croup region [accelerometer]), and right forelimb (gyroscope) before evaluation in 2 consecutive trials, approximately 5 minutes apart, as the horse was trotted in a straight line. Signal-processing algorithms generated overall trial asymmetry measures for vertical head and pelvic movement and stride-by-stride differences in head and pelvic maximum and minimum positions between right and left sides of each stride. Repeatability was determined, and trial difference was determined for groups of horses with various numbers of strides for which data were collected per trial. Inertial sensor-based measures of torso movement asymmetry were repeatable. Repeatability for measures of torso asymmetry for determination of hind limb lameness was slightly greater than that for forelimb lameness. Collecting large numbers of strides degraded stride-to-stride repeatability but did not degrade intertrial repeatability. The inertial sensor system used to measure asymmetry of head and pelvic movement as an aid in the detection and evaluation of lameness in horses trotting in a straight line was sufficiently repeatable to investigate for clinical use.

  13. Controlling urinary tract infections associated with intermittent bladder catheterization in geriatric hospitals.

    PubMed

    Girard, R; Gaujard, S; Pergay, V; Pornon, P; Martin Gaujard, G; Vieux, C; Bourguignon, L

    2015-07-01

    Controlling urinary tract infections (UTIs) associated with intermittent catheterization in geriatric patients. After a local epidemiological study identified high rates of UTI, a multi-disciplinary working group implemented and evaluated corrective measures. In 2009, a one-month prospective study measured the incidence of UTI, controlled for risk factors and exposure, in six geriatric hospitals. In 2010, a self-administered questionnaire on practices was administered to physicians and nurses working in these geriatric units. In 2011, the working group developed a multi-modal programme to: improve understanding of micturition, measurement of bladder volume and indications for catheter drainage; limit available medical devices; and improve prescription and traceability procedures. Detailed training was provided to all personnel on all sites. The epidemiological study was repeated in 2012 to assess the impact of the programme. Over 1500 patients were included in the 2009 study. The incidence of acquired infection was 4.8%. The infection rate was higher in patients with intermittent catheters than in patients with indwelling catheters (29.7 vs 9.9 UTI per 100 patients, P = 0.1013) which contradicts the literature. In 2010, the 269 responses to the questionnaire showed that staff did not consider catheterization to place patients at risk of infection, staff had poor knowledge of the recommended indications and techniques, and the equipment varied widely between units. Following implementation of the programme, the study was repeated in 2012 with over 1500 patients. The frequency of UTI in patients with intermittent catheters fell to rates in the published literature. Multi-modal programmes are an effective means to control UTI. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. The effectiveness of the COPE healthy lifestyles TEEN program: a school-based intervention in middle school adolescents with 12-month follow-up.

    PubMed

    Ardic, Aysun; Erdogan, Semra

    2017-06-01

    The goal of this study is to assess the applicability and long-term effectiveness of the T-COPE Healthy TEEN program on adolescent health. Obesity and mental health disorders are major public health problems in adolescents. In this context, including long-term and multiple behavioural obesity prevention programs are becoming increasingly important. A quasi-experimental design with pre-test/post-test control group and repeated measurements. Eighty-seven (45 in intervention group, 42 in control group) adolescents were included from two different middle schools in the intervention program. The data were analysed by using descriptive statistics, Pearson chi-square, Fisher's exact test, Student-t test, repeated measures of variance analysis and Cohen's d effect size. No significant difference was found between the intervention and control groups in terms of descriptive characteristics, behavioural and cognitive variables of the adolescents. Following the intervention, the adolescents in intervention groups showed improvements in nutritional behaviour, physical activity and stress management. These improvements concerned increased physical walking measured in the number of physical steps per week daily fruit and vegetable consumption and the daily quantity of water ingested. While their nutrition/physical activity knowledge significantly increased, their weight and anxiety symptoms significantly decreased. The effect of the program on body mass index, depression and health beliefs of the adolescents were not significant compared with the control group. The applicability of the T-COPE Healthy TEEN program on Turkish adolescents and its effectiveness on their health behaviours, nutrition and physical activity knowledge and stress management were revealed in this study. © 2016 John Wiley & Sons Ltd.

  15. Quantification of histochemical stains using whole slide imaging: development of a method and demonstration of its usefulness in laboratory quality control.

    PubMed

    Gray, Allan; Wright, Alex; Jackson, Pete; Hale, Mike; Treanor, Darren

    2015-03-01

    Histochemical staining of tissue is a fundamental technique in tissue diagnosis and research, but it suffers from significant variability. Efforts to address this include laboratory quality controls and quality assurance schemes, but these rely on subjective interpretation of stain quality, are laborious and have low reproducibility. We aimed (1) to develop a method for histochemical stain quantification using whole slide imaging and image analysis and (2) to demonstrate its usefulness in measuring staining variation. A method to quantify the individual stain components of histochemical stains on virtual slides was developed. It was evaluated for repeatability and reproducibility, then applied to control sections of an appendix to quantify H&E staining (H/E intensities and H:E ratio) between automated staining machines and to measure differences between six regional diagnostic laboratories. The method was validated with <0.5% variation in H:E ratio measurement when using the same scanner for a batch of slides (ie, it was repeatable) but was not highly reproducible between scanners or over time, where variation of 7% was found. Application of the method showed H:E ratios between three staining machines varied from 0.69 to 0.93, H:E ratio variation over time was observed. Interlaboratory comparison demonstrated differences in H:E ratio between regional laboratories from 0.57 to 0.89. A simple method using whole slide imaging can be used to quantify and compare histochemical staining. This method could be deployed in routine quality assurance and quality control. Work is needed on whole slide imaging devices to improve reproducibility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Parenting Intervention for Prevention of Behavioral Problems in Elementary School-Age Filipino-American Children: A Pilot Study in Churches.

    PubMed

    Javier, Joyce R; Coffey, Dean M; Schrager, Sheree M; Palinkas, Lawrence A; Miranda, Jeanne

    This study aims to test an evidence-based parenting program offered in churches among Filipino-American parents and estimate effect size for a fully powered trial. Twenty-two parents of children aged 6 to 12 years were randomly assigned to either an intervention or a waiting-list control group. Parents' perceptions of child behavior, parenting practices, and parenting stress were obtained at baseline. Parents in the experimental group attended The Incredible Years School Age Program, which consisted of 12 weekly 2-hour sessions. A follow-up assessment was performed after the intervention and 12 weeks later. The intervention was subsequently repeated with the control group. Satisfaction was assessed with a 40-item measure. Analysis of covariance was used to compare the intervention group postintervention versus the control group. Paired t-tests compared mean parenting practices, parenting stress, and child behavior outcomes. Satisfaction was assessed descriptively. Twenty-two parents completed all assessments and the intervention. Analysis of variance comparing intervention and control groups with repeated measures (pre- and post-test measures) revealed that the program has a positive impact on parenting stress, parenting practices (physical punishment, positive verbal discipline), and parent's perception of their child's behavior (internalizing symptoms, externalizing symptoms, and number of problematic behaviors). Analyses of all participants comparing pre- and post intervention revealed improvements in parenting stress, positive verbal discipline, and child externalizing and total problem behaviors. Families reported high satisfaction with the content and format of the intervention. Results support the feasibility of providing an evidence-based parenting program to Filipino parents in churches to prevent future behavioral health problems.

  17. The impact of a school-based gardening intervention on intentions and behaviour related to fruit and vegetable consumption in children.

    PubMed

    Duncan, Michael J; Eyre, Emma; Bryant, Elizabeth; Clarke, Neil; Birch, Samantha; Staples, Victoria; Sheffield, David

    2015-06-01

    A total of 77 children (34 boys, 43 girls, mean age ± standard deviation = 9 ± 1 years) participated in this study; 46 children (intervention) undertook a 12-week school gardening programme and 31 children acted as controls. Measures of the Theory of Planned Behaviour and fruit and vegetable consumption were taken pre- and post-intervention. Repeated measures analysis of variance and hierarchical regression analysis indicated that the intervention group increased daily consumption of fruits and vegetables and increased intentions, attitudes, norms, and perceived behavioural control related to fruit and vegetable consumption. Attitudes, norms and perceived behavioural control significantly predicted changes in fruit and vegetable consumption. © The Author(s) 2015.

  18. Behavioral reactivity to acute stress among Black and White women with type 2 diabetes: The roles of income and racial discrimination.

    PubMed

    Bermudez-Millan, Angela; Schumann, Kristina P; Feinn, Richard; Tennen, Howard; Wagner, Julie

    2016-09-01

    This study investigated relationships of income and self-reported racial discrimination to diabetes health behaviors following an acute stressor. A total of 77 diabetic women (51% Black, 49% White) completed a laboratory public speaking stressor. That evening, participants reported same-day eating, alcohol consumption, and medication adherence; physical activity was measured with actigraphy, and the next morning participants reported sleep quality. Measures were repeated on a counterbalanced control day. There was no mean level difference in health behaviors between stressor and control days. On stressor day, lower income predicted lower physical activity, sleep quality, and medication adherence, and higher racial discrimination predicted more eating and alcohol consumed, even after accounting confounders including race and control day behaviors. © The Author(s) 2015.

  19. Word repetition in amnesia. Electrophysiological measures of impaired and spared memory.

    PubMed

    Olichney, J M; Van Petten, C; Paller, K A; Salmon, D P; Iragui, V J; Kutas, M

    2000-09-01

    Amnesic patients often show improved performance when stimuli are repeated, even in the absence of conscious memory for those stimuli. Although these performance changes are typically attributed to perceptual or motor systems, in some cases they may be related to basic language processing. We examined two neurophysiological measures that vary with word repetition in 12 amnesic patients and 12 control subjects: (i) a late positive component of the event-related potential (ERP) linked to conscious memory and (ii) the N400 component that varies with language comprehension. In each trial, the subject heard a category name, then viewed a word, and then decided whether the word was semantically congruous or incongruous (e.g. 'yes' for 'baby animal: cub'; 'no' for 'water sport: kitchen'). Recall and recognition testing at the end of the experiment showed that control subjects had better memory for congruous than for incongruous words, as did the amnesic patients, who performed less well overall. In contrast, amnesic patients were unimpaired on the category decisions required in each trial and, like the control subjects, showed a large N400 for incongruous relative to congruous words. Similarly, when incongruous trials were repeated after 0-13 intervening trials, N400s were reduced in both groups. When congruous trials were repeated, a late positive repetition effect was observed, but only in the control group. Furthermore, the amplitude of the late positive repetition effect was highly correlated with later word recall in both patients and controls. In the patients, the correlation was also observed with memory scores from standardized neuropsychological tests. These data are consistent with a proposed link between the late positive repetition effect and conscious memory. On the other hand, the N400 repetition effect was not correlated with episodic memory abilities, but instead indexed an aspect of memory that was intact in the amnesic patients. The preserved N400 repetition effect is an example of preserved memory in amnesia that does not easily fit into the categories of low-level perceptual processing or of motor learning. Instead, the sensitivity of the N400 to both semantic context and repetition may reflect a short-term memory process that serves language comprehension in realtime.

  20. Can father inclusive practice reduce paternal postnatal anxiety? A repeated measures cohort study using the hospital anxiety and depression scale

    PubMed Central

    2012-01-01

    Background Perinatal research on anxiety and depression has primarily focused on mothers. We have limited knowledge of fathers’ anxiety during the perinatal period yet there is evidence that the parenting capacity of a person can be compromised by anxiety and depression. The purpose of this paper is to identify the impact of a father inclusive intervention on perinatal anxiety and depression. The prime focus of the intervention was to provide education and support to fathers of breastfeeding partners with the aim of increasing both initiation and duration of breastfeeding. Methods A repeated measures cohort study was conducted during a RCT that was implemented across eight public maternity hospitals in Perth, Western Australia between May 2008 and June 2009. A baseline questionnaire which included the Hospital Anxiety and Depression Scale (HADS) was administered to all participants on the first night of their hospital based antenatal education program and was repeated at six weeks postnatal. SPSS version 17 was used for reporting descriptive results. Results The mean anxiety levels at baseline for the fathers in the intervention group (n=289) and control group (n=244) were 4.58 and 4.22 respectively. At 6 weeks postnatal (only matched pairs), intervention and control group were 3.93 and 3.79. More intervention group fathers self-rated less anxiety compared to the fathers in the control group from baseline to post test (p=0.048). Depression scores for intervention fathers at baseline (mean =1.09) and at six weeks (mean=1.09) were very similar to fathers in the control group at baseline (mean=1.11) and at six weeks (mean =1.07) with no significant changes. Conclusions Both intervention and control group fathers experienced some anxiety prior to the birth of their baby, but this was rapidly reduced at six weeks. Paternal anxiety is common to new fathers and providing them with information and strategies for problem-solving can increase their knowledge and potentially lower the risk of postnatal anxiety. Trial registration (Australian New Zealand Clinical Trials Registry ACTRN12609000667213) PMID:22849509

  1. Corticosterone stress response shows long-term repeatability and links to personality in free-living Nazca boobies.

    PubMed

    Grace, Jacquelyn K; Anderson, David J

    2014-11-01

    The concept of "coping styles", or consistently different responses to stressors, is of broad interest in behavioral ecology and biomedicine. Two critical predictions of this concept are individual consistency of neurophysiological and behavioral responses (relative to population variability) and a negative relationship between aggression/proactivity and hypothalamic-pituitary-adrenal axis reactivity. Recent studies failed to provide strong support for these predictions, especially outside of strictly controlled conditions, and long-term measures to test the first prediction are rare. Here, we demonstrate individual repeatability across 2-3years of maximum circulating corticosterone concentration [CORT] and area under the [CORT] response curve (AUCI) during a standard capture-restraint test in wild, free-living adult Nazca boobies (Sula granti). We also show that the stress response predicts the personality traits aggression and anxiety in these birds (measured in the wild); however, the strength of these results was weak. Maximum [CORT] and AUCI showed higher repeatability between years than baseline [CORT]. After controlling breeding status, sex, mass, date sampled, and their interactions, baseline [CORT] was most closely related to personality traits, followed by AUCI, and then maximum [CORT]. The direction of these relationships depended on whether the testing context was social or non-social. [CORT] parameters had little to no relationship with cross-context plasticity in personality traits. Our results generally affirm two critical predictions of coping styles, but match the emerging trend that these relationships are weak in the wild, and may depend on testing context. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Control of thermal deformation in dielectric mirrors using mechanical design and atomic layer deposition.

    PubMed

    Gabriel, Nicholas T; Kim, Sangho S; Talghader, Joseph J

    2009-07-01

    A mechanical design technique for optical coatings that simultaneously controls thermal deformation and optical reflectivity is reported. The method requires measurement of the refractive index and thermal stress of single films prior to the design. Atomic layer deposition was used for deposition because of the high repeatability of the film constants. An Al2O3/HfO2 distributed Bragg reflector was deposited with a predicted peak reflectivity of 87.9% at 542.4 nm and predicted edge deformation of -360 nm/K on a 10 cm silicon substrate. The measured peak reflectivity was 85.7% at 541.7 nm with an edge deformation of -346 nm/K.

  3. Psychological effects of custody disputes on children.

    PubMed

    Wolman, R; Taylor, K

    1991-01-01

    This two-group, repeated measures examination of the psychological impact of child custody contests on children reports a subset of data from an ongoing longitudinal study of 95 children and their parents from 43 divorcing families. The authors report clinical observations concerning children's experience of custody litigation, as well as comparisons of baseline and post-test responses of contested and uncontested groups on measures of locus of control, separation anxiety and family concept. Contested children exhibited significantly greater internality of control orientation than the normative sample. Contested children's test scores also suggested significantly less separation anxiety and significantly more positive family concept than the uncontested group at post-test. The implications of these unanticipated findings are discussed.

  4. Bidirectional nucleolar dysfunction in C9orf72 frontotemporal lobar degeneration.

    PubMed

    Mizielinska, Sarah; Ridler, Charlotte E; Balendra, Rubika; Thoeng, Annora; Woodling, Nathan S; Grässer, Friedrich A; Plagnol, Vincent; Lashley, Tammaryn; Partridge, Linda; Isaacs, Adrian M

    2017-04-18

    An intronic GGGGCC expansion in C9orf72 is the most common known cause of both frontotemporal lobar degeneration (FTLD) and amyotrophic lateral sclerosis (ALS). The repeat expansion leads to the generation of sense and antisense repeat RNA aggregates and dipeptide repeat (DPR) proteins, generated by repeat-associated non-ATG translation. The arginine-rich DPR proteins poly(glycine-arginine or GR) and poly(proline-arginine or PR) are potently neurotoxic and can localise to the nucleolus when expressed in cells, resulting in enlarged nucleoli with disrupted functionality. Furthermore, GGGGCC repeat RNA can bind nucleolar proteins in vitro. However, the relevance of nucleolar stress is unclear, as the arginine-rich DPR proteins do not localise to the nucleolus in C9orf72-associated FTLD/ALS (C9FTLD/ALS) patient brain. We measured nucleolar size in C9FTLD frontal cortex neurons using a three-dimensional, volumetric approach. Intriguingly, we found that C9FTLD brain exhibited bidirectional nucleolar stress. C9FTLD neuronal nucleoli were significantly smaller than control neuronal nucleoli. However, within C9FTLD brains, neurons containing poly(GR) inclusions had significantly larger nucleolar volumes than neurons without poly(GR) inclusions. In addition, expression of poly(GR) in adult Drosophila neurons led to significantly enlarged nucleoli. A small but significant increase in nucleolar volume was also observed in C9FTLD frontal cortex neurons containing GGGGCC repeat-containing RNA foci. These data show that nucleolar abnormalities are a consistent feature of C9FTLD brain, but that diverse pathomechanisms are at play, involving both DPR protein and repeat RNA toxicity.

  5. Impact of Playing Exergames on Mood States: A Randomized Controlled Trial.

    PubMed

    Huang, Han-Chung; Wong, May-Kuen; Yang, Ya-Hui; Chiu, Hsin-Ying; Teng, Ching-I

    2017-04-01

    To examine how playing exergames impacts the mood states of university students and staff, and whether such an impact depends on gender and players' previous exercise time. This study was designed as a randomized controlled trial. It enrolled 337 participants and randomly assigned them to an intervention group (n = 168) or a control group (n = 167). A 2-week exergame program was designed for the participants in the intervention group. They were required to play exergames for 30 consecutive minutes each week for 2 weeks and respond to the items measuring vigor, happiness, and perceived stress. All measures were administered before and after the study. Repeated measures analysis of variances were conducted. Playing exergames enhanced vigor and happiness for participants in the intervention group. This group exhibited more positive change in vigor and happiness than the control group. This effect of playing exergames was not moderated by gender, age, occupation (student or staff), or previous exercise time. Playing exergames may induce positive mood states among university students and staff.

  6. Dosimetry audits and intercomparisons in radiotherapy: A Malaysian profile

    NASA Astrophysics Data System (ADS)

    M. Noor, Noramaliza; Nisbet, A.; Hussein, M.; Chu S, Sarene; Kadni, T.; Abdullah, N.; Bradley, D. A.

    2017-11-01

    Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 μm core diameter Ge-doped silica fibres (Ge-9 μm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%.

  7. Ultrasonic assessment of hepatic blood flow as a marker of mouse hepatocarcinoma.

    PubMed

    Bonnin, Philippe; Villemain, Aude; Vincent, François; Debbabi, Haythem; Silvestre, Jean Sébastien; Contreres, Jean Olivier; Levy, Bernard I; Tobelem, Gérard; Dupuy, Evelyne

    2007-04-01

    Two-dimensional color-coded pulsed Doppler ultrasonography (US) with a 12-MHz linear transducer was used to follow tumor growth and neoangiogenesis development in 12 transgenic mice developing a whole liver hepatocellular carcinoma (HCC) induced by the expression of SV40-T antigen. In this model, male mice developed HCC at various temporal and histologic stages (hyperplastic, four-eight wk; nodular, 12 wk; diffuse carcinoma, 16-20 wk), whereas female mice remained tumor free. Seven age-matched tumor-free mice were used as controls. Liver volume was calculated from B-mode images of the abdomen. Blood flow waveforms were recorded from the hepatic tumor-feeding artery upstream from the tumor vessels, allowing quantitative blood flow velocity measurements. Measurements were performed every four weeks from four to 20 weeks. As early as the hyperplastic stage (eight weeks), liver volume was increased by 2.7-fold, hepatic artery peak-systolic blood flow velocities (BFV) by 1.5-fold, end-diastolic BFV by 1.6-fold and mean BFV by 2.0-fold compared with control values (p < 0.001). Differences increased until 20 weeks and peak-systolic reached 90 +/- 6, end-diastolic 54 +/- 5 and mean BFV 48 +/- 5 cm s(-1). Successive measurements of BFV were reproducible and intraobserver repeatability coefficient values were <3 cm s(-1). In contrast, mesenteric artery BFV, which did not supply tumor region, did not show any significant difference with respect to control values. Thus, an increase in BFV constitutes a functional evaluation of tumor vascularity. In preclinical studies in small animals, measurements of liver volume and blood flow velocities in hepatic tumor-feeding artery provide a useful, reproducible, noninvasive, easy-to-repeat tool to monitor tumor growth and neoangiogenesis in hepatocellular carcinoma in mice.

  8. Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET.

    PubMed

    Harms, Hendrik Johannes; Stubkjær Hansson, Nils Henrik; Tolbod, Lars Poulsen; Kim, Won Yong; Jakobsen, Steen; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiaer, Jørgen; Sörensen, Jens

    2016-09-01

    Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. Study design and methodology for a multicentre, randomised controlled trial of transcranial direct current stimulation as a treatment for unipolar and bipolar depression.

    PubMed

    Alonzo, Angelo; Aaronson, Scott; Bikson, Marom; Husain, Mustafa; Lisanby, Sarah; Martin, Donel; McClintock, Shawn M; McDonald, William M; O'Reardon, John; Esmailpoor, Zeinab; Loo, Colleen

    2016-11-01

    Transcranial Direct Current Stimulation (tDCS) is a new, non-invasive neuromodulation approach for treating depression that has shown promising efficacy. The aim of this trial was to conduct the first international, multicentre randomised controlled trial of tDCS as a treatment for unipolar and bipolar depression. The study recruited 120 participants across 6 sites in the USA and Australia. Participants received active or sham tDCS (2.5mA, 20 sessions of 30min duration over 4weeks), followed by a 4-week open label active treatment phase and a 4-week taper phase. Mood and neuropsychological outcomes were assessed with the primary antidepressant outcome measure being the Montgomery-Asberg Depression Rating Scale (MADRS). A neuropsychological battery was administered to assess safety and examine cognitive effects. The study also investigated the possible influence of genetic polymorphisms on outcomes. The trial was triple-blinded. Participants, tDCS treaters and study raters were blinded to each participant's tDCS group allocation in the sham-controlled phase. Specific aspects of tDCS administration, device operation and group allocation were designed to optimise the integrity of blinding. Outcome measures will be tested using a mixed effects repeated measures analysis with the primary factors being Time as a repeated measure, tDCS condition (sham or active) and Diagnosis (unipolar or bipolar). A restricted number of random and fixed factors will be included as required to account for extraneous differences. As a promising treatment, tDCS has excellent potential for translation into widespread clinical use, being cost effective, portable, easy to operate and well tolerated. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Effects of Ankle Braces Upon Agility Course Performance in High School Athletes

    PubMed Central

    Beriau, Mark R.; Cox, William B.; Manning, James

    1994-01-01

    The purpose of this study was to compare the effects of wearing the AircastTM Sports Stirrup, AircastTM Training brace, Swede-OTM brace, and DonJoyTM Ankle Ligament Protector while running an agility course. Eighty-five high school athletes with no history of ankle injury and no experience in wearing any ankle support served as subjects. Each subject participated in four separate testing sessions. During sessions 1 and 4, subjects ran the agility course under the control (unbraced) conditions. Sessions 2 and 3 consisted of randomly wearing the ankle braces while running the agility course. A questionnaire concerning support, comfort, and restriction was completed by each subject after wearing each of the braces. An analysis of variance (ANOVA) with repeated measures revealed that a significant difference existed between the agility times. Tukey's post hoc test indicated that a significant difference existed between each ankle brace and the control 2 agility times as well as a control 1 and control 2 time difference. The control time difference was attributed to a learning effect. An ANOVA with repeated measures of only the four braces revealed that a significant difference existed between the agility times. Tukey's post hoc test showed the only difference was between the DonJoy Ankle Ligament Protector and the Aircast Training brace. We concluded: 1) there is limited practical performance effect upon agility while wearing an ankle brace; and 2) an athlete's perceived comfort, support, and performance restriction are contributing factors that may directly influence the effectiveness of ankle bracing. PMID:16558284

  11. Pupil dilation using a pledget sponge: a randomized controlled trial.

    PubMed

    McCormick, Austin; Srinivasan, Sathish; Harun, Shabbir; Watts, Mark

    2006-08-01

    To show that a pledget soaked in mydriatics and placed in the lower conjunctival fornix is as effective as drops in providing mydriasis for cataract surgery. A randomized, masked, controlled trial of 56 patients assigned to either a pledget group (n=25) or a control eye drops group (n=31) was carried out. Controls had the routine practice of repeated topical mydriatic drops: tropicamide, phenylepherine and atropine. The trial group had a 3-mm pledget trimmed, soaked in mydriatics and placed in the inferior fornix for 20 min. Pupil diameter was measured using a photographic technique with a standard scale shown in each picture. Two masked observers measured the pupils using the scale of the ruler in the developed photograph. All patients completed a 0-10 stinging score prior to surgery. There were no complications. The mean pupil diameter in the control group was 7.23 (6.91-7.94 95% confidence intervals [CI]) and 7.44 (6.96-7.92 95% CI) in the pledget group. There was no statistically significant difference in pupil diameter between the two groups: difference between means 0.21 (-0.32 to 0.75 95% CI) and Student's t-test of the difference between means (t=0.8 and two-tailed) probability P=0.43. There was no significant difference in the stinging scores: Mann-Whitney test P=0.69. The use of a pledget cellulose sponge to deliver mydriatics prior to cataract surgery is as effective as the conventional method of repeated drop administration and was not associated with any adverse effects.

  12. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    PubMed

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Method of controlling injection of oxygen into hydrogen-rich fuel cell feed stream

    DOEpatents

    Meltser, Mark Alexander; Gutowski, Stanley; Weisbrod, Kirk

    2001-01-01

    A method of operating a H.sub.2 --O.sub.2 fuel cell fueled by hydrogen-rich fuel stream containing CO. The CO content is reduced to acceptable levels by injecting oxygen into the fuel gas stream. The amount of oxygen injected is controlled in relation to the CO content of the fuel gas, by a control strategy that involves (a) determining the CO content of the fuel stream at a first injection rate, (b) increasing the O.sub.2 injection rate, (c) determining the CO content of the stream at the higher injection rate, (d) further increasing the O.sub.2 injection rate if the second measured CO content is lower than the first measured CO content or reducing the O.sub.2 injection rate if the second measured CO content is greater than the first measured CO content, and (e) repeating steps a-d as needed to optimize CO consumption and minimize H.sub.2 consumption.

  14. Tuboimpedance: A New Test of Eustachian Tube Function.

    PubMed

    Smith, Matthew E; Zou, Charlie C; Blythe, Andrew J C; Tysome, James R

    2017-04-01

    Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

  15. Effects of repeated ankle stretching on calf muscle-tendon and ankle biomechanical properties in stroke survivors

    PubMed Central

    Gao, Fan; Ren, Yupeng; Roth, Elliot J.; Harvey, Richard; Zhang, Li-Qun

    2011-01-01

    Background The objective of this study was to investigate changes in active and passive biomechanical properties of the calf muscle-tendon unit induced by controlled ankle stretching in stroke survivors. Methods Ten stroke survivors with ankle spasticity/contracture and ten healthy control subjects received intervention of 60-min ankle stretching. Joint biomechanical properties including resistance torque, stiffness and index of hysteresis were evaluated pre- and post-intervention. Achilles tendon length was measured using ultrasonography. The force output of the triceps surae muscles was characterized via the torque-angle relationship, by stimulating the calf muscles at a controlled intensity across different ankle positions. Findings Compared to healthy controls, the ankle position corresponding to the peak torque of the stroke survivors was shifted towards plantar flexion (P<0.001). Stroke survivors showed significantly higher resistance torques and joint stiffness (P<0.05), and these higher resistances were reduced significantly after the stretching intervention, especially in dorsiflexion (P = 0.013). Stretching significantly improved the force output of the impaired calf muscles in stroke survivors under matched stimulations (P<0.05). Ankle range of motion was also increased by stretching (P<0.001). Interpretation At the joint level, repeated stretching loosened the ankle joint with increased passive joint range of motion and decreased joint stiffness. At the muscle-tendon level, repeated stretching improved calf muscle force output, which might be associated with decreased muscle fascicle stiffness, increased fascicle length and shortening of the Achilles tendon. The study provided evidence of improvement in muscle tendon properties through stretching intervention. PMID:21211873

  16. Bias reduction in repeated-measures observational studies by the use of propensity score: the case of enteral sedation for critically ill patients.

    PubMed

    Umbrello, Michele; Mistraletti, Giovanni; Corbella, Davide; Cigada, Marco; Salini, Silvia; Morabito, Alberto; Iapichino, Gaetano

    2012-12-01

    Within the evidence-based medicine paradigm, randomized controlled trials represent the "gold standard" to produce reliable evidence. Indeed, planning and implementing randomized controlled trials in critical care medicine presents limitations because of intrinsic and structural problems. As a consequence, observational studies still occur frequently. In these cases, propensity score (PS) (probability of receiving a treatment conditional on observed covariates) is an increasingly used technique to adjust the results. Few studies addressed the specific issue of a PS correction of repeated-measures designs. Three techniques for correcting the analysis of nonrandomized designs (matching, stratification, regression adjustment) are presented in a tutorial form and applied to a real case study: the comparison between intravenous and enteral sedative therapy in the intensive care unit setting. After showing the results before and after the use of PS, we suggest that such a tool allows to partially overcoming the bias associated with the observational nature of the study. It permits to correct the estimates for any observed covariate, while unobserved confounders cannot be controlled for. Propensity score represents a useful additional tool to estimate the effects of treatments in nonrandomized studies. In the case study, an enteral sedation approach was equally effective to an intravenous regime, allowing for a lower level of sedation and spare of resources. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Not Just Horsing Around: The Impact of Equine-Assisted Learning on Levels of Hope and Depression in At-Risk Adolescents.

    PubMed

    Frederick, Karen E; Ivey Hatz, Julie; Lanning, Beth

    2015-10-01

    Equine-assisted learning (EAL) is an experiential modality which utilizes horses to provide a unique learning experience for personal growth. Research by Damon et al. (Appl Dev Sci 7:119-128, 2003) suggests a positive relationship between hope and positive developmental trajectories. Hagen et al. (Am J Orthopsychiatr 75:211-219, 2005) showed hope to be a protective factor associated with adaptive functioning in at-risk youth. Ashby et al. (J Couns Dev 89:131-139, 2011) found a significant inverse relationship between hope and depression: as hope increases, depression decreases. The current study investigates the impact of a non-riding EAL curriculum entitled L.A.S.S.O. (Leading Adolescents to Successful School Outcomes) on levels of hope and depression in at-risk youth. The study uses an experimental design with longitudinal, repeated measures. Participants were randomly assigned to treatment and control groups. Participants in the treatment received 5 weeks of EAL, while participants in the control group received treatment as usual. Repeated measures ANOVA of participants' levels of hope and depression showed statistically significant improvements in the treatment group as compared with the control group. Even a brief (5-week) intervention of EAL had a positive impact on the lives and attitudes of at-risk adolescents, with increased levels of hope and decreased levels of depression.

  18. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    PubMed

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    PubMed

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Reliability of real-time ultrasound measurement of transversus abdominis thickness in healthy trained subjects.

    PubMed

    Gnat, Rafael; Saulicz, Edward; Miądowicz, Barbara

    2012-08-01

    To investigate intra- and inter-rater reliability of the ultrasound measurement of transversus abdominis (TrA) thickness and thickness change (difference between thickness at rest and during contraction) in asymptomatic, trained subjects. To define the number of repeated measurements that provide acceptable level of reliability. To investigate variability of the measurements over time of 5 days and the reliability of duplicate analysis of images. A single-group repeated-measures design was used to assess reliability. Healthy volunteers (n = 10) were subjected to 1-week training in voluntary activation of TrA. Real-time ultrasound imaging and subsequent measurement of the TrA thickness at rest and during voluntary contraction were repeated on Monday, Wednesday and Friday of the next week. Using a single repeated measurement, intraclass correlation coefficients (ICCs) for TrA thickness were: 0.86-0.95 (intra-rater), 0.86-0.92 (inter-rater); and for TrA thickness change: 0.34-0.56 (intra-rater), 0.47-0.61 (inter-rater). Using the mean of three repeated measurements respective values were: 0.97, 0.96-0.98; and 0.81-0.84, 0.80-0.90. No significant differences were found between mean values of TrA thickness as well as thickness change obtained on three consecutive measurement days. Duplicate analysis of the images was highly reliable with ICCs of 0.89-0.99. Two repeated measurements for TrA thickness and at least three measurements for TrA thickness change are needed to achieve acceptable levels of intra- and inter-rater reliability. In healthy trained volunteers TrA thickness and thickness change are relatively stable parameters over a 5-day period. Duplicate analysis of the same images by two blinded observers is reliable.

  1. Measurement of plasma cell-free DNA concentrations in dogs with sepsis, trauma, and neoplasia.

    PubMed

    Letendre, Jo-Annie; Goggs, Robert

    2017-05-01

    To determine if cell-free DNA (cfDNA) was identifiable in canine plasma, to evaluate 3 techniques for the measurement of plasma cfDNA concentrations in dogs presented to an emergency service, and to compare the plasma cfDNA concentrations of healthy dogs to those with sepsis, trauma, and neoplasia. Retrospective study of banked canine plasma samples collected between May 2014 and December 2014. Dogs presented to the emergency service of a university veterinary teaching hospital. Plasma cfDNA was measured on residual plasma samples obtained from 15 dogs with sepsis, 15 dogs with moderate-severe trauma, 15 dogs diagnosed with a sarcoma. Plasma cfDNA was also measured in 15 healthy dogs. None. Assay linearity, repeatability, and reproducibility were evaluated. Quantification of cfDNA was performed in duplicate on diluted citrated plasma and following DNA purification using 2 fluorescence assays (SYBR-Gold; Quant-iT) and by ultraviolet absorbance spectroscopy. Fluorescence intensities (FIs) were converted to cfDNA concentrations using standard curves. Median FI values and cfDNA concentrations were compared to healthy controls using the Kruskal-Wallis test, with adjustment for multiple comparisons. Alpha was set at 0.05. Both assays had excellent linearity, and acceptable repeatability and reproducibility. Compared to controls, plasma cfDNA concentrations were significantly increased in dogs with sepsis or moderate-severe trauma with both assays (P ≤ 0.003). Dogs with neoplasia had significantly increased cfDNA concentrations with the Quant-iT assay only (P = 0.003). When measurements were performed on purified DNA, only dogs with moderate-severe trauma had significantly increased cfDNA concentrations (P < 0.001; SYBR-Gold assay). cfDNA can be readily identified in canine plasma using 2 fluorescence assays. DNA extraction offers no advantage over direct measurement. Compared to healthy controls, dogs with sepsis or moderate-severe trauma have significantly increased plasma cfDNA concentrations. © Veterinary Emergency and Critical Care Society 2017.

  2. Exogenous agmatine has neuroprotective effects against restraint-induced structural changes in the rat brain

    PubMed Central

    Zhu, Meng-Yang; Wang, Wei-Ping; Cai, Zheng-Wei; Regunathan, Soundar; Ordway, Gregory

    2009-01-01

    Agmatine is an endogenous amine derived from decarboxylation of arginine catalysed by arginine decarboxylase. Agmatine is considered a novel neuromodulator and possesses neuroprotective properties in the central nervous system. The present study examined whether agmatine has neuroprotective effects against repeated restraint stress-induced morphological changes in rat medial prefrontal cortex and hippocampus. Sprague-Dawley rats were subjected to 6 h of restraint stress daily for 21 days. Immunohistochemical staining with β-tubulin III showed that repeated restraint stress caused marked morphological alterations in the medial prefrontal cortex and hippocampus. Stress-induced alterations were prevented by simultaneous treatment with agmatine (50 mg/kg/day, i.p.). Interestingly, endogenous agmatine levels, as measured by high-performance liquid chromatography, in the prefrontal cortex and hippocampus as well as in the striatum and hypothalamus of repeated restraint rats were significantly reduced as compared with the controls. Reduced endogenous agmatine levels in repeated restraint animals were accompanied by a significant increase of arginine decarboxylase protein levels in the same regions. Moreover, administration of exogenous agmatine to restrained rats abolished increases of arginine decarboxylase protein levels. Taken together, these results demonstrate that exogenously administered agmatine has neuroprotective effects against repeated restraint-induced structural changes in the medial prefrontal cortex and hippocampus. These findings indicate that stress-induced reductions in endogenous agmatine levels in the rat brain may play a permissive role in neuronal pathology induced by repeated restraint stress. PMID:18364017

  3. Vulnerability for new episodes in recurrent major depressive disorder: protocol for the longitudinal DELTA-neuroimaging cohort study

    PubMed Central

    Mocking, Roel J T; Figueroa, Caroline A; Rive, Maria M; Geugies, Hanneke; Servaas, Michelle N; Assies, Johanna; Koeter, Maarten W J; Vaz, Frédéric M; Wichers, Marieke; van Straalen, Jan P; de Raedt, Rudi; Bockting, Claudi L H; Harmer, Catherine J; Schene, Aart H; Ruhé, Henricus G

    2016-01-01

    Introduction Major depressive disorder (MDD) is widely prevalent and severely disabling, mainly due to its recurrent nature. A better understanding of the mechanisms underlying MDD-recurrence may help to identify high-risk patients and to improve the preventive treatment they need. MDD-recurrence has been considered from various levels of perspective including symptomatology, affective neuropsychology, brain circuitry and endocrinology/metabolism. However, MDD-recurrence understanding is limited, because these perspectives have been studied mainly in isolation, cross-sectionally in depressed patients. Therefore, we aim at improving MDD-recurrence understanding by studying these four selected perspectives in combination and prospectively during remission. Methods and analysis In a cohort design, we will include 60 remitted, unipolar, unmedicated, recurrent MDD-participants (35–65 years) with ≥2 MDD-episodes. At baseline, we will compare the MDD-participants with 40 matched controls. Subsequently, we will follow-up the MDD-participants for 2.5 years while monitoring recurrences. We will invite participants with a recurrence to repeat baseline measurements, together with matched remitted MDD-participants. Measurements include questionnaires, sad mood-induction, lifestyle/diet, 3 T structural (T1-weighted and diffusion tensor imaging) and blood-oxygen-level-dependent functional MRI (fMRI) and MR-spectroscopy. fMRI focusses on resting state, reward/aversive-related learning and emotion regulation. With affective neuropsychological tasks we will test emotional processing. Moreover, we will assess endocrinology (salivary hypothalamic-pituitary-adrenal-axis cortisol and dehydroepiandrosterone-sulfate) and metabolism (metabolomics including polyunsaturated fatty acids), and store blood for, for example, inflammation analyses, genomics and proteomics. Finally, we will perform repeated momentary daily assessments using experience sampling methods at baseline. We will integrate measures to test: (1) differences between MDD-participants and controls; (2) associations of baseline measures with retro/prospective recurrence-rates; and (3) repeated measures changes during follow-up recurrence. This data set will allow us to study different predictors of recurrence in combination. Ethics and dissemination The local ethics committee approved this study (AMC-METC-Nr.:11/050). We will submit results for publication in peer-reviewed journals and presentation at (inter)national scientific meetings. Trial registration number NTR3768. PMID:26932139

  4. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Treesearch

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  5. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    USGS Publications Warehouse

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  6. Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes

    ERIC Educational Resources Information Center

    Zavorsky, Gerald S.

    2010-01-01

    Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…

  7. Baseline repeated measures from controlled human exposure studies: associations between ambient air pollution exposure and the systemic inflammatory biomarkers IL-6 and fibrinogen.

    PubMed

    Thompson, Aaron M S; Zanobetti, Antonella; Silverman, Frances; Schwartz, Joel; Coull, Brent; Urch, Bruce; Speck, Mary; Brook, Jeffrey R; Manno, Michael; Gold, Diane R

    2010-01-01

    Systemic inflammation may be one of the mechanisms mediating the association between ambient air pollution and cardiovascular morbidity and mortality. Interleukin-6 (IL-6) and fibrinogen are biomarkers of systemic inflammation that are independent risk factors for cardio-vascular disease. We investigated the association between ambient air pollution and systemic inflammation using baseline measurements of IL-6 and fibrinogen from controlled human exposure studies. In this retrospective analysis we used repeated-measures data in 45 nonsmoking subjects. Hourly and daily moving averages were calculated for ozone, nitrogen dioxide, sulfur dioxide, and particulate matter

  8. Improved Auditory Nerve Survival with Nanoengineered Supraparticles for Neurotrophin Delivery into the Deafened Cochlea

    PubMed Central

    Tan, Justin; Wang, Yajun; Caruso, Frank; Shepherd, Robert K.

    2016-01-01

    Cochlear implants electrically stimulate spiral ganglion neurons (SGNs) in order to provide speech cues to severe-profoundly deaf patients. In normal hearing cochleae the SGNs depend on endogenous neurotrophins secreted by sensory cells in the organ of Corti for survival. SGNs gradually degenerate following deafness and consequently there is considerable interest in developing clinically relevant strategies to provide exogenous neurotrophins to preserve SGN survival. The present study investigated the safety and efficacy of a drug delivery system for the cochlea using nanoengineered silica supraparticles. In the present study we delivered Brain-derived neurotrophic factor (BDNF) over a period of four weeks and evaluated SGN survival as a measure of efficacy. Supraparticles were bilaterally implanted into the basal turn of cochleae in profoundly deafened guinea pigs. One ear received BDNF-loaded supraparticles and the other ear control (unloaded) supraparticles. After one month of treatment the cochleae were examined histologically. There was significantly greater survival of SGNs in cochleae that received BDNF supraparticles compared to the contralateral control cochleae (repeated measures ANOVA, p = 0.009). SGN survival was observed over a wide extent of the cochlea. The supraparticles were well tolerated within the cochlea with a tissue response that was localised to the site of implantation in the cochlear base. Although mild, the tissue response was significantly greater in cochleae treated with BDNF supraparticles compared to the controls (repeated measures ANOVA, p = 0.003). These data support the clinical potential of this technology particularly as the supraparticles can be loaded with a variety of therapeutic drugs. PMID:27788219

  9. A quantum Szilard engine without heat from a thermal reservoir

    NASA Astrophysics Data System (ADS)

    Hamed Mohammady, M.; Anders, Janet

    2017-11-01

    We study a quantum Szilard engine that is not powered by heat drawn from a thermal reservoir, but rather by projective measurements. The engine is constituted of a system { S }, a weight { W }, and a Maxwell demon { D }, and extracts work via measurement-assisted feedback control. By imposing natural constraints on the measurement and feedback processes, such as energy conservation and leaving the memory of the demon intact, we show that while the engine can function without heat from a thermal reservoir, it must give up at least one of the following features that are satisfied by a standard Szilard engine: (i) repeatability of measurements; (ii) invariant weight entropy; or (iii) positive work extraction for all measurement outcomes. This result is shown to be a consequence of the Wigner-Araki-Yanase theorem, which imposes restrictions on the observables that can be measured under additive conservation laws. This observation is a first-step towards developing ‘second-law-like’ relations for measurement-assisted feedback control beyond thermality.

  10. Lack of behavioral sensitization to repeated cocaine administration from postnatal days 1 to 10.

    PubMed

    Meyer, J S; Yacht, A C

    1993-09-01

    This research determined whether sensitization (or tolerance) to the behavioral effects of cocaine in rat pups would occur following repeated cocaine administration. Rats were injected daily with 20 mg/kg of cocaine HCl s.c. from postnatal day 1 to day 10, injected with saline vehicle only, or left untreated during this period. On day 11, animals from each group were challenged with either 0, .625, 1.25, or 2.50 mg/kg of cocaine and their behavioral responses were recorded. Prior cocaine treatment did not influence the acute effects of cocaine on ultrasonic vocalizations or on any observed motor responses. In contrast, the cocaine- and saline-treated pups differed in a similar manner from the untreated control group on several behavioral measures. These results indicate that the sensitizing effects of repeated cocaine administration are not manifested during the neonatal period. However, the stimulation (stress) of handling and injection may alter the subsequent responsivity of infant rats to a cocaine challenge.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kozyr, Alex

    This report presents methods, and analytical and quality control procedures for salinity, oxygen, nutrient, inorganic carbon, organic carbon, chlorofluorocarbon (CFC), and bomb carbon-14 system parameters performed during the A20_2003 and A22_2003 cruises, which took place between September 22 and November 13, 2003, aboard research vessel (R/V) Knorr under the auspices of the National Oceanic and Atmospheric Administration (NOAA) and National Science Foundation (NSF). The R/V Knorr departed Woods Hole, Massachusetts, on September 22 for the Repeat Section A20, and ended this line in Port of Spain, Trinidad, on October 20. The Repeat Section A22 started on October 23 in Portmore » of Spain, Trinidad, and finished on November 13, 2003, in Woods Hole, Massachusetts. The research conducted was one of a series of repeat hydrography sections jointly funded by NOAA and NSF as part of the Climate Variability Program (CLIVAR)/CO2/repeat hydrography/tracer program. Samples were taken from 36 depths at 88 stations on section A20 and 82 stations on section A22. The data presented in this report include the analyses of water samples for total inorganic carbon (TCO 2), total alkalinity (TALK), dissolved organic carbon (DOC), CFC, carbon-14, hydrographic, and other chemical measurements.« less

  12. Development of a Genomic DNA Reference Material Panel for Myotonic Dystrophy Type 1 (DM1) Genetic Testing

    PubMed Central

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine

    2014-01-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132

  13. Force Measurement Improvements to the National Transonic Facility Sidewall Model Support System

    NASA Technical Reports Server (NTRS)

    Goodliff, Scott L.; Balakrishna, Sundareswara; Butler, David; Cagle, C. Mark; Chan, David; Jones, Gregory S.; Milholen, William E., II

    2016-01-01

    The National Transonic Facility is a transonic pressurized cryogenic facility. The development of the high Reynolds number semi-span capability has advanced over the years to include transonic active flow control and powered testing using the sidewall model support system. While this system can be used in total temperatures down to -250Â F for conventional unpowered configurations, it is limited to temperatures above -60Â F when used with powered models that require the use of the high-pressure air delivery system. Thermal instabilities and non-repeatable mechanical arrangements revealed several data quality shortfalls by the force and moment measurement system. Recent modifications to the balance cavity recirculation system have improved the temperature stability of the balance and metric model-to-balance hardware. Changes to the mechanical assembly of the high-pressure air delivery system, particularly hardware that interfaces directly with the model and balance, have improved the repeatability of the force and moment measurement system. Drag comparisons with the high-pressure air system removed will also be presented in this paper.

  14. Repeatability Modeling for Wind-Tunnel Measurements: Results for Three Langley Facilities

    NASA Technical Reports Server (NTRS)

    Hemsch, Michael J.; Houlden, Heather P.

    2014-01-01

    Data from extensive check standard tests of seven measurement processes in three NASA Langley Research Center wind tunnels are statistically analyzed to test a simple model previously presented in 2000 for characterizing short-term, within-test and across-test repeatability. The analysis is intended to support process improvement and development of uncertainty models for the measurements. The analysis suggests that the repeatability can be estimated adequately as a function of only the test section dynamic pressure over a two-orders- of-magnitude dynamic pressure range. As expected for low instrument loading, short-term coefficient repeatability is determined by the resolution of the instrument alone (air off). However, as previously pointed out, for the highest dynamic pressure range the coefficient repeatability appears to be independent of dynamic pressure, thus presenting a lower floor for the standard deviation for all three time frames. The simple repeatability model is shown to be adequate for all of the cases presented and for all three time frames.

  15. Mentors Offering Maternal Support (M.O.M.S.)

    DTIC Science & Technology

    2011-08-02

    at Sessions 1, 5, and 8. Table 1. Pretest - posttest , randomized, controlled, repeated measured design Experimental Intervention Sessions...theoretical mediators of self-esteem and emotional support (0.6 standard deviation change from pretest to posttest ) with reduction of effect to 0.4...always brought back to the designated topic . In order to have statistically significant results for the outcome variables the study sessions must

  16. Perceived Academic Performance, Self-Esteem and Locus of Control as Indicators of Need for Assessment of Adolescent Suicide Risk: Implications for Teachers

    ERIC Educational Resources Information Center

    Martin, Graham; Richardson, Angela S.; Bergen, Helen A.; Roeger, Leigh; Allison, Stephen

    2005-01-01

    Introduction: There is currently a need for research into indicators that could be used by non-clinical professionals working with young people, to inform the need for referral for further clinical assessment of those at risk of suicide. Method: Participants of this repeated measures longitudinal study, were 2603, 2485, and 2246 school students…

  17. Comparing Dynamic Treatment Regimes Using Repeated-Measures Outcomes: Modeling Considerations in SMART Studies

    PubMed Central

    Lu, Xi; Nahum-Shani, Inbal; Kasari, Connie; Lynch, Kevin G.; Oslin, David W.; Pelham, William E.; Fabiano, Gregory; Almirall, Daniel

    2016-01-01

    A dynamic treatment regime (DTR) is a sequence of decision rules, each of which recommends a treatment based on a patient’s past and current health status. Sequential, multiple assignment, randomized trials (SMARTs) are multi-stage trial designs that yield data specifically for building effective DTRs. Modeling the marginal mean trajectories of a repeated-measures outcome arising from a SMART presents challenges, because traditional longitudinal models used for randomized clinical trials do not take into account the unique design features of SMART. We discuss modeling considerations for various forms of SMART designs, emphasizing the importance of considering the timing of repeated measures in relation to the treatment stages in a SMART. For illustration, we use data from three SMART case studies with increasing level of complexity, in autism, child attention deficit hyperactivity disorder (ADHD), and adult alcoholism. In all three SMARTs we illustrate how to accommodate the design features along with the timing of the repeated measures when comparing DTRs based on mean trajectories of the repeated-measures outcome. PMID:26638988

  18. Comparing dynamic treatment regimes using repeated-measures outcomes: modeling considerations in SMART studies.

    PubMed

    Lu, Xi; Nahum-Shani, Inbal; Kasari, Connie; Lynch, Kevin G; Oslin, David W; Pelham, William E; Fabiano, Gregory; Almirall, Daniel

    2016-05-10

    A dynamic treatment regime (DTR) is a sequence of decision rules, each of which recommends a treatment based on a patient's past and current health status. Sequential, multiple assignment, randomized trials (SMARTs) are multi-stage trial designs that yield data specifically for building effective DTRs. Modeling the marginal mean trajectories of a repeated-measures outcome arising from a SMART presents challenges, because traditional longitudinal models used for randomized clinical trials do not take into account the unique design features of SMART. We discuss modeling considerations for various forms of SMART designs, emphasizing the importance of considering the timing of repeated measures in relation to the treatment stages in a SMART. For illustration, we use data from three SMART case studies with increasing level of complexity, in autism, child attention deficit hyperactivity disorder, and adult alcoholism. In all three SMARTs, we illustrate how to accommodate the design features along with the timing of the repeated measures when comparing DTRs based on mean trajectories of the repeated-measures outcome. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Utilizing Telemedicine in the Trauma Intensive Care Unit: Does It Impact Teamwork?

    PubMed

    Lazzara, Elizabeth H; Benishek, Lauren E; Patzer, Brady; Gregory, Megan E; Hughes, Ashley M; Heyne, Kyle; Salas, Eduardo; Kuchkarian, Fernanda; Marttos, Antonio; Schulman, Carl

    2015-08-01

    The aim of this study was to examine the impact of a telemedical robot on trauma intensive care unit (TICU) clinician teamwork (i.e., team attitudes, behaviors, and cognitions) during patient rounds. Thirty-two healthcare providers who conduct rounds volunteered to take surveys assessing teamwork attitudes and cognitions at three time periods: (1) the onset of the study, (2) the end of the 30-day control period, and (3) the end of the 30-day experimental period, which immediately followed the control period. Rounds were recorded throughout the 30-day control period and 30-day experimental period to observe provider behaviors. For the initial 30 days, there was no access to telemedicine. For the final 30 days, the rounding healthcare providers had access to the RP-7 robot (Intouch Health Inc., Santa Barbara, CA), a telemedical tool that can facilitate patient rounds conducted away from bedside. Using a one-tailed, one-way repeated-measures analysis of variance (ANOVA) to compare trust at Times 1, 2, and 3, there was no significant effect on trust: F(2, 14)=1.20, p=0.16. When a one-tailed, one-way repeated-measures ANOVA to compare transactive memory systems (TMS) at Times 1, 2, and 3 was conducted, there was no significant effect on TMS: F(2, 15)=1.33, p=0.15. We conducted a one-tailed, one-way repeated-measures ANOVA to compare team psychological safety at Times 1, 2, and 3, and there was no significant effect on team psychological safety: F(2,15)=1.53, p=0.12. There was a significant difference in communication between rounds with and without telemedicine [t(25)=-1.76, p<0.05], such that there was more task-based communication during telerounds. Telemedicine increased task-based communication and did not negatively impact team trust, psychological safety, or TMS during rounds. Telemedicine may offer advantages for some teamwork competencies without sacrificing the efficacy of others and may be adopted by intact rounding teams without hindering teamwork.

  20. Effects of Expressive Writing Effects on Disgust and Anxiety in a Subsequent Dissection

    NASA Astrophysics Data System (ADS)

    Randler, Christoph; Wüst-Ackermann, Peter; im Kampe, Viola Otte; Meyer-Ahrens, Inga H.; Tempel, Benjamin J.; Vollmer, Christian

    2015-10-01

    Emotions influence motivation and achievement, but negative emotions have rarely been assessed in science education. In this study, we assessed the influence of two different expressive writing assignments on disgust and anxiety in university students prior to the dissection of a trout. We randomly assigned students to one of two expressive writing tasks and measured specific state disgust and state anxiety after writing and after the dissection. Specific state disgust was measured a third time after 3 weeks. One writing task was concerned with the dissection, and the other was related to behavioral experiments with mice. We used two general linear models with repeated measures. In the first model, specific state disgust (pre, post, and follow-up) was used as the dependent repeated measure and experimental group as the independent variable. In the second model, state anxiety was used as the dependent repeated measure (pre, post) with experimental group as the independent variable. The repeated testing showed a highly significant effect of experimental group on the repeated measures of disgust. Writing about worries and emotions concerning the dissection leads to higher disgust scores compared to writing about mice. These higher scores persisted even 3 weeks later in the follow-up test. Concerning anxiety, there was a clear influence of the repeated measure of state anxiety, but anxiety was not influenced by the experimental group. We suggest that positive writing should be used in educational contexts to reduce disgust.

  1. Evaluating channel morphologic changes and bed-material transport using airborne lidar, upper Colorado River, Rocky Mountain National Park, Colorado

    NASA Astrophysics Data System (ADS)

    Mangano, Joseph F.

    A debris flow associated with the 2003 breach of Grand Ditch in Rocky Mountain National Park, Colorado provided an opportunity to determine controls on channel geomorphic responses following a large sedimentation event. Due to the remote site location and high spatial and temporal variability of processes controlling channel response, repeat airborne lidar surveys in 2004 and 2012 were used to capture conditions along the upper Colorado River and tributary Lulu Creek i) one year following the initial debris flow, and ii) following two bankfull flows (2009 and 2010) and a record-breaking long duration, high intensity snowmelt runoff season (2011). Locations and volumes of aggradation and degradation were determined using lidar differencing. Channel and valley metrics measured from the lidar surveys included water surface slope, valley slope, changes in bankfull width, sinuosity, braiding index, channel migration, valley confinement, height above the water surface along the floodplain, and longitudinal profiles. Reaches of aggradation and degradation along the upper Colorado River are influenced by valley confinement and local controls. Aggradational reaches occurred predominantly in locations where the valley was unconfined and valley slope remained constant through the length of the reach. Channel avulsions, migration, and changes in sinuosity were common in all unconfined reaches, whether aggradational or degradational. Bankfull width in both aggradational and degradational reaches showed greater changes closer to the sediment source, with the magnitude of change decreasing downstream. Local variations in channel morphology, site specific channel conditions, and the distance from the sediment source influence the balance of transport supply and capacity and, therefore, locations of aggradation, degradation, and associated morphologic changes. Additionally, a complex response initially seen in repeat cross-sections is broadly supported by lidar differencing, although the differencing captures only the net change over eight years and not annual changes. Lidar differencing shows great promise because it reveals vertical and horizontal trends in morphologic changes at a high resolution over a large area. Repeat lidar surveys were also used to create a sediment budget along the upper Colorado River by means of the morphologic inverse method. In addition to the geomorphic changes detected by lidar, several levels of attrition of the weak clasts within debris flow sediment were applied to the sediment budget to reduce gaps in expected inputs and outputs. Bed-material estimates using the morphologic inverse method were greater than field-measured transport estimates, but the two were within an order of magnitude. Field measurements and observations are critical for robust interpretation of the lidar-based analyses because applying lidar differencing without field control may not identify local controls on valley and channel geometry and sediment characteristics. The final sediment budget helps define variability in bed-material transport and constrain transport rates through the site, which will be beneficial for restoration planning. The morphologic inverse method approach using repeat lidar surveys appears promising, especially if lidar resolution is similar between sequential surveys.

  2. Expression of extracellular matrix metalloproteinase inducer (EMMPRIN) in the endometrium of patients with repeated implantation failure after in vitro fertilization.

    PubMed

    Turgut, A; Goruk, N Y; Tunc, S Y; Agaçayak, E; Alabalik, U; Yalinkaya, A; Gül, T

    2014-01-01

    To compare the immunohistochemical expression of extracellular matrix metalloproteinase inducer (EMMPRIN) in repeated implantation failure (RIF) patients with normal fertile controls. The study group consisted of primary infertile patients with RIF and normal fertile controls between January 2011 and February 2013. Endometrial samples received at the luteal phase were exposed to immunohistochemical staining for EMMPRIN antibodies. EMMPRIN expression of endometrial glandular epithelial cells, stromal cells and vascular endothelial cells were evaluated. The main outcome measure was defined as immunohistochemical score with regard to the severity and extent of staining. The study group consisted of 26 primary infertile patients, whereas the control group consisted of 40 normal fertile controls. The fertile group was found to have stronger expression of EMMPRIN than the study group when endometrial glandular epithelial cells, stromal cells and vascular endothelial cells were evaluated with regards to the severity of staining (p < 0.001), the extent of staining (p < 0.001) and total staining score (p < 0.001). This is the first study showing low expression of EMMPRIN in the endometrial cells of the patients with RIF compared with fertile healthy controls. We suggest that reduced EMMPRIN expression in the human endometrium may lead to poor endometrial receptivity.

  3. Controlled assembly of organic whispering-gallery-mode microlasers as highly sensitive chemical vapor sensors.

    PubMed

    Gao, Miaomiao; Wei, Cong; Lin, Xianqing; Liu, Yuan; Hu, Fengqin; Zhao, Yong Sheng

    2017-03-09

    We demonstrate the fabrication of organic high Q active whispering-gallery-mode (WGM) resonators from π-conjugated polymer by a controlled emulsion-solvent-evaporation method, which can simultaneously provide optical gain and act as an effective resonant cavity. By measuring the shift of their lasing modes on exposure to organic vapor, we successfully monitored the slight concentration variation in the chemical gas. These microlaser sensors demonstrated high detection sensitivity and good signal repeatability under continuous chemical gas treatments. The results offer an effective strategy to design miniaturized optical sensors.

  4. Self-Administered Questionnaire Is a Reliable Measure of Coffee Consumption

    PubMed Central

    Sääksjärvi, Katri; Knekt, Paul; Männistö, Satu; Heliövaara, Markku

    2010-01-01

    Background The objective of this study was to assess the agreement and repeatability of 2 methods of measuring habitual coffee consumption, and to examine their homogeneity with respect to socioeconomic and lifestyle factors. Methods Data on coffee consumption were collected from 4254 subjects by means of a health questionnaire (HQ) and a 1-year dietary history interview (DHI), the latter of which was used as the reference method during the Finnish Mobile Clinic Health Examination Survey conducted in 1973–1976. Short-term repeatability of the methods was assessed using data from 286 and 93 subjects who repeated the HQ and the DHI, respectively, after an interval of 4 to 8 months. The strength of agreement between the 2 methods and between the repeated measurements was estimated using intraclass correlation coefficients (ICCs). Results The ICC was 0.86 for the agreement between the HQ and the DHI, and 0.77 and 0.85 for the repeatability of the HQ and the DHI, respectively. There were no statistically significant systematic differences in mean intake values between the 2 methods or between repeated measurements. In subgroup analysis of background variables, there were only minor differences in agreement and repeatability, with somewhat higher ICC values among subjects with a healthier lifestyle and higher education. Conclusions The high reliability and homogeneity of the health questionnaire make it a useful tool for measuring habitual coffee consumption for the purposes of epidemiological research. PMID:20671374

  5. EFFECT OF A ROAD SAFETY EDUCATION INTERVENTION ON ROAD SAFETY KNOWLEDGE OF UNIVERSITY DRIVERS IN IBADAN, NIGERIA.

    PubMed

    Olumide, A O; Owoaje, E T

    2016-06-01

    It is essential for drivers employed in the formal sector to have good knowledge of road safety in order to safeguard their lives and those of the staff they are employed to drive. The study was conducted to determine the effect of a road safety education intervention on road safety knowledge of drivers employed in the University of Ibadan, Nigeria. A quasi-experimental study of 98 intervention and 78 control drivers selected using a cluster sampling technique was conducted. The intervention comprised a two-day training on road safety and first aid. The drivers' knowledge of road safety was measured at baseline, immediately and 4-months post-intervention. Aggregate scores of road safety knowledge were computed giving minimum and maximum obtainable scores of 0 and 16 respectively. Change in mean scores over the three measurement periods was assessed using Repeated Measures Analysis of Variance (ANOVA). Independent t-test was used to compare the scores between intervention and control drivers at each of the assessment periods. Twenty-nine drivers did not complete the study (attrition rate = 16.5%). At baseline, mean road safety knowledge scores for the intervention and control drivers were 12.7±2.2 and 12.9± 2.3 (p = 0.510) respectively. Immediately and four months post intervention, the scores of the intervention drivers were 13.8±1.9 and 12.8±1.6; while scores for the controls were 13.3±2.0 and 13.2±1.8. Repeated measures ANOVA revealed that the increase in knowledge over the three assessment periods was not statistically significant. The intervention resulted in an initial increase in road safety knowledge of the intervention drivers. However, this was not sustained to the forth month post-intervention. This finding suggests periodic refresher trainings to sustain the knowledge acquired.

  6. Comparison of the Effects of Lanolin, Peppermint, and Dexpanthenol Creams on Treatment of Traumatic Nipples in Breastfeeding Mothers.

    PubMed

    Shanazi, Mahnaz; Farshbaf Khalili, Azizeh; Kamalifard, Mahin; Asghari Jafarabadi, Mohammad; Masoudin, Kazhal; Esmaeli, Fariba

    2015-12-01

    Traumatic nipple is among the most common problems of the breastfeeding period which leads to early cessation of breastfeeding. The study aimed to compare the effects of the lanolin, peppermint, and dexpanthenol creams on the treatment of traumatic nipples. This double-blind randomized controlled trial was carried out on 126 breastfeeding mothers. The mothers had visited at the health centers and children's hospitals in Sanandaj City. The selected participants were randomly divided into the following three groups of lanolin, peppermint, and dexpanthenol cream groups. Nipple pain was measured using the Store scale while trauma was measured with the Champion scale. Analyses were carried out through the Kruskal-Wallis test, Chi-square, ANOVA, and repeated measures ANOVA by using SPSS software ver. 13. The result showed that the mean score of nipple pain and nipple trauma at the prior to intervention stage, third, seventh, and fourteenth days of intervention was not significantly different between three groups. But, repeated measures ANOVA showed a significant difference in comparison of the four time periods of intervention in each group. RESULTS of this study revealed that the lanolin, peppermint, and dexpanthenol medicines had similar therapeutic effects on traumatic nipple.

  7. 47 CFR 22.573 - Use of base transmitters as repeaters.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Use of base transmitters as repeaters. 22.573... of base transmitters as repeaters. As an additional function, base transmitters may be used as repeaters. Licensees must be able to turn the base transmitter on or off from the control point regardless...

  8. 47 CFR 22.573 - Use of base transmitters as repeaters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Use of base transmitters as repeaters. 22.573... of base transmitters as repeaters. As an additional function, base transmitters may be used as repeaters. Licensees must be able to turn the base transmitter on or off from the control point regardless...

  9. 47 CFR 22.573 - Use of base transmitters as repeaters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 2 2012-10-01 2012-10-01 false Use of base transmitters as repeaters. 22.573... of base transmitters as repeaters. As an additional function, base transmitters may be used as repeaters. Licensees must be able to turn the base transmitter on or off from the control point regardless...

  10. 47 CFR 22.573 - Use of base transmitters as repeaters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Use of base transmitters as repeaters. 22.573... of base transmitters as repeaters. As an additional function, base transmitters may be used as repeaters. Licensees must be able to turn the base transmitter on or off from the control point regardless...

  11. Predicting out-of-office blood pressure level using repeated measurements in the clinic: an observational cohort study

    PubMed Central

    Sheppard, James P.; Holder, Roger; Nichols, Linda; Bray, Emma; Hobbs, F.D. Richard; Mant, Jonathan; Little, Paul; Williams, Bryan; Greenfield, Sheila; McManus, Richard J.

    2014-01-01

    Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35–84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice. PMID:25144295

  12. Early-developmental stress, repeatability, and canalization in a suite of physiological and behavioral traits in female zebra finches.

    PubMed

    Careau, Vincent; Buttemer, William A; Buchanan, Katherine L

    2014-10-01

    Adaptive developmental plasticity allows individuals experiencing poor environmental conditions in early life to adjust their life-history strategy in order to prioritize short-term fitness benefits and maximize reproductive output in challenging environments. Much research has been conducted to test whether such adoption of a "faster" life-history strategy is accompanied by concordant changes in behavior and physiology, with mixed results. As research in this field has focused on comparison of mean-level responses of treatment groups, few studies include repeated measures of response variables and the effect that developmental stress may have on repeatability per se. We investigated how early-developmental stress affects the mean expression of (and repeatability in) a variety of behavioral and physiological traits in female zebra finches. We predicted that: (1) individuals subjected to nutritional restriction in the nestling phase would have higher feeding and activity rates, with associated increases in hematocrit and basal metabolic rates (BMRs), (2) nutritional restriction in early life would alter adults' stress-induced corticosterone level, and (3) developmental stress would, respectively, influence the amount of among-individual and within-individual variation in behavioral and physiological traits, hence affecting the repeatability of these traits. In comparison to control females, stressed females did not differ in activity rate or stress-induced corticosterone level, but they did have higher levels of feeding, hematocrit, and BMR. Among-individual variance and repeatability were generally higher in stressed females than in controls. Finally, we found that developmental dietary restriction significantly reduced the amount of within-individual variance both in activity rate in the novel environment and in stress-induced corticosterone level. Our results not only confirm previous findings on the effect of early-developmental stress on BMR, but also extend its effect to feeding rate and hematocrit, suggesting that developmental plasticity in these traits is ontogenetically linked. Early-developmental stress may disable particular genetic canalizing processes, which would release cryptic genetic variation and explain why repeatability and among-individual variance were generally higher in the stressed groups than in controls. For activity rate in the novel environment and with stress-induced corticosterone level, however, early-developmental stress significantly reduced within-individual variance, which may be a consequence of increased canalization of these traits at the micro-environmental level. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  13. Environmental enrichment of brown capuchins (Cebus apella): Behavioral and plasma and fecal cortisol measures of effectiveness

    USGS Publications Warehouse

    Boinski, S.; Swing, S.P.; Gross, T.S.; Davis, J.K.

    1999-01-01

    No consensus exists about the quantity and variety of environmental enrichment needed to achieve an acceptable level of psychological well-being among singly housed primates. Behavioral and plasma and fecal cortisol measures were used to evaluate the effectiveness of four levels of toy and foraging enrichment provided to eight wild-caught, singly housed adult male brown capuchins (Cebus apella). The 16-week-long study comprised six conditions and began with a 4-week-long preexperimental and ended with a 4-week-long postexperimental period during which the subjects were maintained at baseline enrichment levels. During the intervening 8 weeks, the subjects were randomly assigned to a sequence of four 2-week-long experimental conditions: control (baseline conditions), toy (the addition of two plastic toys to each cage), box (access to a foraging box with food treats hidden within crushed alfalfa), and box and toy (the addition of two plastic toys and access to a foraging box). Behavioral responses to changes in enrichment were rapid and extensive. Within-subject repeated-measure ANOVAs with planned post hoc contrasts identified highly significant reductions in abnormal and undesirable behaviors (and increases in normal behaviors) as the level of enrichment increased from control to toy to box to box and toy. No significant behavioral differences were found between the control and pre- and postexperimental conditions. Plasma and fecal cortisol measures revealed a different response to changing enrichment levels. Repeated-measure ANOVA models found significant changes in both these measures across the six conditions. The planned post hoc analyses, however, while finding dramatic increases in cortisol titers in both the pre- and postexperimental conditions relative to the control condition, did not distinguish cortisol responses among the four enrichment levels. Linear regressions among weekly group means in behavioral and cortisol measures (n = 16) found that plasma cortisol was significantly predicted by the proportions of both normal and abnormal behaviors; as the proportion of normal behaviors increased, the plasma cortisol measures decreased. Plasma cortisol weekly group means were also significantly and positively predicted by fecal cortisol weekly group means, but no behavioral measure significantly predicted fecal cortisol weekly group means. In sum, these findings argue strongly that access to a variety of toy and foraging enrichment positively affects behavioral and physiological responses to stress and enhances psychological well-being in singly housed brown capuchins.

  14. Environmental enrichment of brown capuchins (Cebus apella): behavioral and plasma and fecal cortisol measures of effectiveness.

    PubMed

    Boinski, S; Swing, S P; Gross, T S; Davis, J K

    1999-01-01

    No consensus exists about the quantity and variety of environmental enrichment needed to achieve an acceptable level of psychological well-being among singly housed primates. Behavioral and plasma and fecal cortisol measures were used to evaluate the effectiveness of four levels of toy and foraging enrichment provided to eight wild-caught, singly housed adult male brown capuchins (Cebus apella). The 16-week-long study comprised six conditions and began with a 4-week-long preexperimental and ended with a 4-week-long postexperimental period during which the subjects were maintained at baseline enrichment levels. During the intervening 8 weeks, the subjects were randomly assigned to a sequence of four 2-week-long experimental conditions: control (baseline conditions), toy (the addition of two plastic toys to each cage), box (access to a foraging box with food treats hidden within crushed alfalfa), and box & toy (the addition of two plastic toys and access to a foraging box). Behavioral responses to changes in enrichment were rapid and extensive. Within-subject repeated-measure ANOVAs with planned post hoc contrasts identified highly significant reductions in abnormal and undesirable behaviors (and increases in normal behaviors) as the level of enrichment increased from control to toy to box to box & toy. No significant behavioral differences were found between the control and pre- and postexperimental conditions. Plasma and fecal cortisol measures revealed a different response to changing enrichment levels. Repeated-measure ANOVA models found significant changes in both these measures across the six conditions. The planned post hoc analyses, however, while finding dramatic increases in cortisol titers in both the pre- and postexperimental conditions relative to the control condition, did not distinguish cortisol responses among the four enrichment levels. Linear regressions among weekly group means in behavioral and cortisol measures (n=16) found that plasma cortisol was significantly predicted by the proportions of both normal and abnormal behaviors; as the proportion of normal behaviors increased, the plasma cortisol measures decreased. Plasma cortisol weekly group means were also significantly and positively predicted by fecal cortisol weekly group means, but no behavioral measure significantly predicted fecal cortisol weekly group means. In sum, these findings argue strongly that access to a variety of toy and foraging enrichment positively affects behavioral and physiological responses to stress and enhances psychological well-being in singly housed brown capuchins.

  15. Androgen receptor repeat length polymorphism associated with male-to-female transsexualism.

    PubMed

    Hare, Lauren; Bernard, Pascal; Sánchez, Francisco J; Baird, Paul N; Vilain, Eric; Kennedy, Trudy; Harley, Vincent R

    2009-01-01

    There is a likely genetic component to transsexualism, and genes involved in sex steroidogenesis are good candidates. We explored the specific hypothesis that male-to-female transsexualism is associated with gene variants responsible for undermasculinization and/or feminization. Specifically, we assessed the role of disease-associated repeat length polymorphisms in the androgen receptor (AR), estrogen receptor beta (ERbeta), and aromatase (CYP19) genes. Subject-control analysis included 112 male-to-female transsexuals and 258 non-transsexual males. Associations and interactions were investigated between CAG repeat length in the AR gene, CA repeat length in the ERbeta gene, and TTTA repeat length in the CYP19 gene and male-to-female transsexualism. A significant association was identified between transsexualism and the AR allele, with transsexuals having longer AR repeat lengths than non-transsexual male control subjects (p=.04). No associations for transsexualism were evident in repeat lengths for CYP19 or ERbeta genes. Individuals were then classified as short or long for each gene polymorphism on the basis of control median polymorphism lengths in order to further elucidate possible combined effects. No interaction associations between the three genes and transsexualism were identified. This study provides evidence that male gender identity might be partly mediated through the androgen receptor.

  16. Androgen Receptor Repeat Length Polymorphism Associated with Male-to-Female Transsexualism

    PubMed Central

    Hare, Lauren; Bernard, Pascal; Sánchez, Francisco J.; Baird, Paul N.; Vilain, Eric; Kennedy, Trudy; Harley, Vincent R.

    2012-01-01

    Background There is a likely genetic component to transsexualism, and genes involved in sex steroidogenesis are good candidates. We explored the specific hypothesis that male-to-female transsexualism is associated with gene variants responsible for undermasculinization and/or feminization. Specifically, we assessed the role of disease-associated repeat length polymorphisms in the androgen receptor (AR), estrogen receptor β (ERβ), and aromatase (CYP19) genes. Methods Subject-control analysis included 112 male-to-female transsexuals and 258 non-transsexual males. Associations and interactions were investigated between CAG repeat length in the AR gene, CA repeat length in the ERβ gene, and TTTA repeat length in the CYP19 gene and male-to-female transsexualism. Results A significant association was identified between transsexualism and the AR allele, with transsexuals having longer AR repeat lengths than non-transsexual male control subjects (p = .04). No associations for transsexualism were evident in repeat lengths for CYP19 or ERβ genes. Individuals were then classified as short or long for each gene polymorphism on the basis of control median polymorphism lengths in order to further elucidate possible combined effects. No interaction associations between the three genes and transsexualism were identified. Conclusions This study provides evidence that male gender identity might be partly mediated through the androgen receptor. PMID:18962445

  17. Validation of a 3D CT method for measurement of linear wear of acetabular cups.

    PubMed

    Jedenmalm, Anneli; Nilsson, Fritjof; Noz, Marilyn E; Green, Douglas D; Gedde, Ulf W; Clarke, Ian C; Stark, Andreas; Maguire, Gerald Q; Zeleznik, Michael P; Olivecrona, Henrik

    2011-02-01

    We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.

  18. Effects of Plyometric Training and Beta-Alanine Supplementation on Maximal-Intensity Exercise and Endurance in Female Soccer Players

    PubMed Central

    Rosas, Fabián; Ramírez-Campillo, Rodrigo; Martínez, Cristian; Cañas-Jamet, Rodrigo; McCrudden, Emma; Meylan, Cesar; Moran, Jason; Nakamura, Fábio Y.; Pereira, Lucas A.; Loturco, Irineu; Diaz, Daniela; Izquierdo, Mikel

    2017-01-01

    Abstract Plyometric training and beta-alanine supplementation are common among soccer players, although its combined use had never been tested. Therefore, a randomized, double-blind, placebo-controlled trial was conducted to compare the effects of a plyometric training program, with or without beta-alanine supplementation, on maximal-intensity and endurance performance in female soccer players during an in-season training period. Athletes (23.7 ± 2.4 years) were assigned to either a plyometric training group receiving a placebo (PLACEBO, n = 8), a plyometric training group receiving beta-alanine supplementation (BA, n = 8), or a control group receiving placebo without following a plyometric training program (CONTROL, n = 9). Athletes were evaluated for single and repeated jumps and sprints, endurance, and change-of-direction speed performance before and after the intervention. Both plyometric training groups improved in explosive jumping (ES = 0.27 to 1.0), sprinting (ES = 0.31 to 0.78), repeated sprinting (ES = 0.39 to 0.91), 60 s repeated jumping (ES = 0.32 to 0.45), endurance (ES = 0.35 to 0.37), and change-of-direction speed performance (ES = 0.36 to 0.58), whereas no significant changes were observed for the CONTROL group. Nevertheless, compared to the CONTROL group, only the BA group showed greater improvements in endurance, repeated sprinting and repeated jumping performances. It was concluded that beta-alanine supplementation during plyometric training may add further adaptive changes related to endurance, repeated sprinting and jumping ability. PMID:28828081

  19. Effects of Plyometric Training and Beta-Alanine Supplementation on Maximal-Intensity Exercise and Endurance in Female Soccer Players.

    PubMed

    Rosas, Fabián; Ramírez-Campillo, Rodrigo; Martínez, Cristian; Caniuqueo, Alexis; Cañas-Jamet, Rodrigo; McCrudden, Emma; Meylan, Cesar; Moran, Jason; Nakamura, Fábio Y; Pereira, Lucas A; Loturco, Irineu; Diaz, Daniela; Izquierdo, Mikel

    2017-09-01

    Plyometric training and beta-alanine supplementation are common among soccer players, although its combined use had never been tested. Therefore, a randomized, double-blind, placebo-controlled trial was conducted to compare the effects of a plyometric training program, with or without beta-alanine supplementation, on maximal-intensity and endurance performance in female soccer players during an in-season training period. Athletes (23.7 ± 2.4 years) were assigned to either a plyometric training group receiving a placebo (PLACEBO, n = 8), a plyometric training group receiving beta-alanine supplementation (BA, n = 8), or a control group receiving placebo without following a plyometric training program (CONTROL, n = 9). Athletes were evaluated for single and repeated jumps and sprints, endurance, and change-of-direction speed performance before and after the intervention. Both plyometric training groups improved in explosive jumping (ES = 0.27 to 1.0), sprinting (ES = 0.31 to 0.78), repeated sprinting (ES = 0.39 to 0.91), 60 s repeated jumping (ES = 0.32 to 0.45), endurance (ES = 0.35 to 0.37), and change-of-direction speed performance (ES = 0.36 to 0.58), whereas no significant changes were observed for the CONTROL group. Nevertheless, compared to the CONTROL group, only the BA group showed greater improvements in endurance, repeated sprinting and repeated jumping performances. It was concluded that beta-alanine supplementation during plyometric training may add further adaptive changes related to endurance, repeated sprinting and jumping ability.

  20. Design ATE systems for complex assemblies

    NASA Astrophysics Data System (ADS)

    Napier, R. S.; Flammer, G. H.; Moser, S. A.

    1983-06-01

    The use of ATE systems in radio specification testing can reduce the test time by approximately 90 to 95 percent. What is more, the test station does not require a highly trained operator. Since the system controller has full power over all the measurements, human errors are not introduced into the readings. The controller is immune to any need to increase output by allowing marginal units to pass through the system. In addition, the software compensates for predictable, repeatable system errors, for example, cabling losses, which are an inherent part of the test setup. With no variation in test procedures from unit to unit, there is a constant repeatability factor. Preparing the software, however, usually entails considerable expense. It is pointed out that many of the problems associated with ATE system software can be avoided with the use of a software-intensive, or computer-intensive, system organization. Its goal is to minimize the user's need for software development, thereby saving time and money.

  1. Previous tubal ectopic pregnancy raises the incidence of repeated ectopic pregnancies in in vitro fertilization-embryo transfer patients.

    PubMed

    Weigert, Monika; Gruber, Diego; Pernicka, Elisabeth; Bauer, Peter; Feichtinger, Wilfried

    2009-01-01

    To investigate the incidence of Tubal Ectopic Pregnancies (TEP) in IVF-ET patients with respect to the status of the fallopian tubes after a previous TEP. This retrospective study compares patients undergoing 481 IVF-ET cycles after conservatively or surgically treated TEP(s) with a Control Group (idiopathic or male factor for IVF-ET indication). Medical reports of surgery and/or hysterosalpingograms prior to the IVF cycles classified the status of the fallopian tubes. 12 TEPs (8.95%/Pregnancies (PR)) occurred in the Study Group. In the Control Group one TEP (0.75%/PR; p < 0.001) was found. Smoking increased the probability of TEPs (p = 0.0028) and of pathological pregnancies (abortion, biochemical and ectopic PR; (p = 0.0411)). For statistic evolution logistic regression (PROC GENMOD) and a repeated measure model were applied. Women with a previous TEP should be informed about the significantly increased risk for a further TEP in IVF-ET treatment, especially if they are smoking.

  2. Monoamine oxidase A inhibitor occupancy during treatment of major depressive episodes with moclobemide or St. John’s wort: an [11C]-harmine PET study

    PubMed Central

    Sacher, Julia; Houle, Sylvain; Parkes, Jun; Rusjan, Pablo; Sagrati, Sandra; Wilson, Alan A.; Meyer, Jeffrey H.

    2011-01-01

    Background Monoamine oxidase A (MAO-A) inhibitor antidepressants raise levels of multiple monoamines, whereas the selective serotonin reuptake inhibitors (SSRIs) only raise extracellular serotonin. Despite this advantage of MAO-A inhibitors, there is much less frequent development of MAO inhibitors compared with SSRIs. We sought to measure brain MAO-A occupancy after 6 weeks of treatment in depressed patients with a clinically effective dose of a selective MAO-A inhibitor and measure MAO-A occupancy after repeated administration of St. John’s wort, an herb purported to have MAO-A inhibitor properties. Methods Participants underwent 2 [11C]-harmine positron emission tomography scans. Healthy controls completed a test–retest condition, and depressed patients were scanned before and after repeated administration of moclobemide or St. John’s wort for 6 weeks at the assigned dose. We measured MAO-A VT, an index of MAO-A density, in the prefrontal, anterior cingulate and anterior temporal cortices, putamen, thalamus, midbrain and hippocampus. Results We included 23 participants (10 controls and 13 patients with major depressive disorder [MDD]) in our study. Monoamine oxidase A VT decreased significantly throughout all regions after moclobemide treatment in patients with MDD compared with controls (repeated-measures analysis of variance, F1,15 = 71.08–130.06, p < 0.001 for all regions, mean occupancy 74% [standard deviation 6%]). Treatment with St. John’s wort did not significantly alter MAO-A VT. Limitations The occupancy estimates are limited by the sample size of each treatment group; hence, our estimate for the overall moclobemide occupancy of 74% has a 95% confidence interval of 70%–78%, and we can estimate with 95% certainty that the occupancy of St. John’s wort is less than 5%. Conclusion For new MAO-A inhibitors, about 74% occupancy at steady-state dosing is desirable. Consistent with this, St. John’s wort should not be classified as an MAO-A inhibitor. The magnitude of MAO-A blockade during moclobemide treatment exceeds the elevation of MAO-A binding during illness by at least 30%, suggesting that the treatment effect should exceed the disease effect when designing selective anti-depressants for this target. PMID:21463543

  3. PTSD and DNA Methylation in Select Immune Function Gene Promoter Regions: A Repeated Measures Case-control Study of U.S. Military Service Members

    DTIC Science & Technology

    2013-06-24

    barrier induced by status epilepticus within the rat piriform cortex in interferon-gamma inde- pendent pathway. Brain Res. 1447, 126–134. doi:10.1016...hippocampus following status epilepticus . Neuroscience 170, 711–721. doi:10.1016/j.neuroscience. 2010.07.048 Sananbenesi, F., and Fischer, A. (2009). The...methylation status of each CpG locus was analyzed individually as a T/C SNP using QCpG software (Qiagen Pyrosequencing). The loci of specific CpGs measured

  4. Temporal Asthma Patterns Using Repeated Questionnaires over 13 Years in a Large French Cohort of Women

    PubMed Central

    Sanchez, Margaux; Bousquet, Jean; Le Moual, Nicole; Jacquemin, Bénédicte; Clavel-Chapelon, Françoise; Humbert, Marc; Kauffmann, Francine; Tubert-Bitter, Pascale; Varraso, Raphaëlle

    2013-01-01

    Variable expression is one aspect of the heterogeneity of asthma. We aimed to define a variable pattern, which is relevant in general health epidemiological cohorts. Our objectives were to assess whether: 1) asthma patterns defined using simple asthma questions through repeated measurements could reflect disease variability 2) these patterns may further be classified according to asthma severity/control. Among 70,428 French women, we used seven questionnaires (1992–2005) and a comprehensive reimbursement database (2004–2009) to define three reliable asthma patterns based on repeated positive answers to the ever asthma attack question: “never asthma” (n = 64,061); “inconsistent” (“yes” followed by “no”, n = 3,514); “consistent” (fully consistent positive answers, n = 2,853). The “Inconsistent” pattern was related to both long-term (childhood-onset asthma with remission in adulthood) and short-term (reported asthma attack in the last 12 months, associated with asthma medication) asthma variability, showing that repeated questions are relevant markers of the variable expression of asthma. Furthermore, in this pattern, the number of positive responses (1992–2005) predicted asthma drug consumption in subsequent years, a marker of disease severity. The “Inconsistent” pattern is a phenotype that may capture the variable expression of asthma. Repeated answers, even to a simple question, are too often neglected. PMID:23741466

  5. Return of Postural Control to Baseline After Anaerobic and Aerobic Exercise Protocols

    PubMed Central

    Fox, Zachary G; Mihalik, Jason P; Blackburn, J Troy; Battaglini, Claudio L; Guskiewicz, Kevin M

    2008-01-01

    Context: With regard to sideline concussion testing, the effect of fatigue associated with different types of exercise on postural control is unknown. Objective: To evaluate the effects of fatigue on postural control in healthy college-aged athletes performing anaerobic and aerobic exercise protocols and to establish an immediate recovery time course from each exercise protocol for postural control measures to return to baseline status. Design: Counterbalanced, repeated measures. Setting: Research laboratory. Patients Or Other Participants: Thirty-six collegiate athletes (18 males, 18 females; age  =  19.00 ± 1.01 years, height  =  172.44 ± 10.47 cm, mass  =  69.72 ± 12.84 kg). Intervention(s): Participants completed 2 counterbalanced sessions within 7 days. Each session consisted of 1 exercise protocol followed by postexercise measures of postural control taken at 3-, 8-, 13-, and 18-minute time intervals. Baseline measures were established during the first session, before the specified exertion protocol was performed. Main Outcome Measure(s): Balance Error Scoring System (BESS) results, sway velocity, and elliptical sway area. Results: We found a decrease in postural control after each exercise protocol for all dependent measures. An interaction was noted between exercise protocol and time for total BESS score (P  =  .002). For both exercise protocols, all measures of postural control returned to baseline within 13 minutes. Conclusions: Postural control was negatively affected after anaerobic and aerobic exercise protocols as measured by total BESS score, elliptical sway area, and sway velocity. The effect of exertion lasted up to 13 minutes after each exercise was completed. Certified athletic trainers and clinicians should be aware of these effects and their recovery time course when determining an appropriate time to administer sideline assessments of postural control after a suspected mild traumatic brain injury. PMID:18833307

  6. Physiological measures in participants with chronic fatigue syndrome, multiple sclerosis and healthy controls following repeated exercise: a pilot study.

    PubMed

    Hodges, L D; Nielsen, T; Baken, D

    2017-08-07

    To compare physiological responses of chronic fatigue syndrome (CFS/ME), multiple sclerosis (MS) and healthy controls (HC) following a 24-h repeated exercise test. Ten CFS, seven MS and 17 age- and gender-matched healthy controls (10, CFS HC; and seven, MS HC) were recruited. Each participant completed a maximal incremental cycle exercise test on day 1 and again 24 h later. Heart rate (HR), blood pressure (BP), rating of perceived exertion (RPE), oxygen consumption (V˙O2), carbon dioxide production and workload (WL) were recorded. Data analysis investigated these responses at anaerobic threshold (AT) and peak work rate (PWR). On day 2, both CFS and MS had significantly reduced max workload compared to HC. On day 2, significant differences were apparent in WL between CFS and CFS HC (93 ± 37 W, 132 ± 42 W, P<0·042). CFS workload decreased on day 2, alongside a decrease in HR but with an increase in V˙O2 (ml   kg   min -1 ). This was in comparison with an increase in WL, HR and V˙O2 for CFS HC. MS demonstrated a decreased WL compared to MS HC on both days of the study (D1 81 ± 30 W, 116 ±30 W; D2 84 ± 29 W, 118 ± 36 W); however, patients with MS were able to achieve a higher WL on day 2 alongside MS HC. These results suggest that exercise exhibits a different physiological response in MS and CFS/ME, demonstrating repeated cardiovascular exercise testing as a valid measure for differentiating between fatigue conditions. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  7. Layered Architectures for Quantum Computers and Quantum Repeaters

    NASA Astrophysics Data System (ADS)

    Jones, Nathan C.

    This chapter examines how to organize quantum computers and repeaters using a systematic framework known as layered architecture, where machine control is organized in layers associated with specialized tasks. The framework is flexible and could be used for analysis and comparison of quantum information systems. To demonstrate the design principles in practice, we develop architectures for quantum computers and quantum repeaters based on optically controlled quantum dots, showing how a myriad of technologies must operate synchronously to achieve fault-tolerance. Optical control makes information processing in this system very fast, scalable to large problem sizes, and extendable to quantum communication.

  8. A mathematical theory of learning control for linear discrete multivariable systems

    NASA Technical Reports Server (NTRS)

    Phan, Minh; Longman, Richard W.

    1988-01-01

    When tracking control systems are used in repetitive operations such as robots in various manufacturing processes, the controller will make the same errors repeatedly. Here consideration is given to learning controllers that look at the tracking errors in each repetition of the process and adjust the control to decrease these errors in the next repetition. A general formalism is developed for learning control of discrete-time (time-varying or time-invariant) linear multivariable systems. Methods of specifying a desired trajectory (such that the trajectory can actually be performed by the discrete system) are discussed, and learning controllers are developed. Stability criteria are obtained which are relatively easy to use to insure convergence of the learning process, and proper gain settings are discussed in light of measurement noise and system uncertainties.

  9. Effects of repeated exposure of rats to JP-5 or JP-8 jet fuel vapor on neurobehavioral capacity and neurotransmitter levels.

    PubMed

    Rossi, J; Nordholm, A F; Carpenter, R L; Ritchie, G D; Malcomb, W

    2001-07-20

    The U.S. Naval Service is anticipating transition from the nearly exclusive use of JP-5 jet fuel to predominant use of JP-8, consistent with the primary utilization by the U.S. Army, U.S. Air Force, and the militaries of most NATO countries. To compare the relative risk of repeated exposure to JP-5 versus JP-8 vapor, groups of 32 male Sprague-Dawley rats each were exposed for 6 h/d, 5 d/wk for 6 wk (180 h) to JP-8 jet fuel vapor (1,000 +/- 10% mg/m3), IP-5 vapor (1,200 +/- 10% mg/m3), or room air control conditions. Following a 65-d rest period, rats completed 10 tests selected from the Neurobehavioral Toxicity Assessment Battery (NTAB) to evaluate changes in performance capacity. Repeated exposure to JP-5 resulted in significant effects on only one test, forelimb grip strength (FGS), while exposure to JP-8 vapor resulted in a significant difference versus controls on appetitive reinforcer approach sensitization (ARAS). Rats were further evaluated for concentrations of major neurotransmitters and metabolites in five brain regions and in the blood serum. Levels of dopamine, the dopamine metabolite dihydroxyphenylacetic acid (DOPAC), and the serotonin metabolite homovanillic acid (HVA) were significantly modulated in various brain regions, as measured 85+ d postexposure. Similarly, serum levels of the serotonin metabolite 5-hydroxyindoleacetic acid (5-HIAA) were differentially modulated following JP-8 or JP-5 exposure. Results are compared to previously published research evaluating the neurotoxicity of repeated exposure to other hydrocarbon fuels and solvents.

  10. Helicopter noise measurements repeatability program final report

    DOT National Transportation Integrated Search

    1987-09-01

    This report summarizes the findings of the Helicopter Noise Measurement Repeatability Program (HNMRP), which was initiated by the International Civil Aviation Organization (ICAO) Committee on Aviation Environmental Protection (CAEP) Working Group II ...

  11. Short- and long-term variability of radon progeny concentration in dwellings in the Czech Republic.

    PubMed

    Slezáková, M; Navrátilová Rovenská, K; Tomásek, L; Holecek, J

    2013-03-01

    In this paper, repeated measurements of radon progeny concentration in dwellings in the Czech Republic are described. Two distinct data sets are available: one based on present measurements in 170 selected dwellings in the Central Bohemian Pluton with a primary measurement carried out in the 1990s and the other based on 1920 annual measurements in 960 single-family houses in the Czech Republic in 1992 and repeatedly in 1993. The analysis of variance model with random effects is applied to data to evaluate the variability of measurements. The calculated variability attributable to repeated measurements is compared with results from other countries. In epidemiological studies, ignoring the variability of measurements may lead to biased estimates of risk of lung cancer.

  12. The Beast of Aggregating Cognitive Load Measures in Technology-Based Learning

    ERIC Educational Resources Information Center

    Leppink, Jimmie; van Merriënboer, Jeroen J. G.

    2015-01-01

    An increasing part of cognitive load research in technology-based learning includes a component of repeated measurements, that is: participants are measured two or more times on the same performance, mental effort or other variable of interest. In many cases, researchers aggregate scores obtained from repeated measurements to one single sum or…

  13. Weight Shame, Social Connection, and Depressive Symptoms in Late Adolescence

    PubMed Central

    Brewis, Alexandra A.; Bruening, Meg

    2018-01-01

    Child and adolescent obesity is increasingly the focus of interventions, because it predicts serious disease morbidity later in life. However, social environments that permit weight-related stigma and body shame may make weight control and loss more difficult. Rarely do youth obesity interventions address these complexities. Drawing on repeated measures in a large sample (N = 1443) of first-year (freshman), campus-resident university students across a nine-month period, we model how weight-related shame predicts depressive symptom levels, how being overweight (assessed by anthropometric measures) shapes that risk, and how social connection (openness to friendship) might mediate/moderate. Body shame directly, clearly, and repeatedly predicts depression symptom levels across the whole school year for all students, but overweight youth have significantly elevated risk. Social connections mediate earlier in the school year, and in all phases moderate, body shame effects on depression. Youth obesity interventions would be well-served recognizing and incorporating the influential roles of social-environmental factors like weight stigma and friendship in program design. PMID:29723962

  14. Benefits of the uncertainty management intervention for African American and White older breast cancer survivors: 20-month outcomes.

    PubMed

    Gil, Karen M; Mishel, Merle H; Belyea, Michael; Germino, Barbara; Porter, Laura S; Clayton, Margaret

    2006-01-01

    In a 2 x 2 randomized block repeated measure design, this study evaluated the follow-up efficacy of the uncertainty management intervention at 20 months. The sample included 483 recurrence-free women (342 White, 141 African American women; mean age = 64 years) who were 5-9 years posttreatment for breast cancer. Women were randomly assigned to either the intervention or usual care control condition. The intervention was delivered during 4 weekly telephone sessions in which survivors were guided in the use of audiotaped cognitive-behavioral strategies and a self-help manual. Repeated measures MANOVAs evaluating treatment group, ethnic group, and treatment by ethnic interaction effects at 20 months indicated that training in uncertainty management resulted in improvements in cognitive reframing, cancer knowledge, and a variety of coping skills. Importantly, the 20-month outcomes also demonstrated benefits for women in the intervention condition in terms of declines in illness uncertainty and stable effects in personal growth over time.

  15. The effect of a family-based intervention with a cognitive-behavioral approach on elder abuse.

    PubMed

    Khanlary, Zahra; Maarefvand, Masoomeh; Biglarian, Akbar; Heravi-Karimooi, Majideh

    2016-01-01

    Elder abuse may become a health issue in developing countries, including Iran. The purpose of this investigation was to study the effectiveness of Family-Based Cognitive-Behavioral Social Work (FBCBSW) in reducing elder abuse. In a randomized clinical trial in Iran, 27 elders participated in intervention and control groups. The intervention groups received a five-session FBCBSW intervention and completed the Domestic-Elder-Abuse-Questionnaire (DEAQ), which evaluates elder abuse at baseline and follow-ups. Repeated measures of analysis of variance (ANOVA) and the Wilcoxon test were used to analyze the data. The repeated measures ANOVA revealed that FBCBSW was successful in reducing elder abuse. The Wilcoxon test indicated that emotional neglect, care neglect, financial neglect, curtailment of personal autonomy, psychological abuse, and financial abuse significantly decreased over time, but there was no statistically significant difference in physical abuse before and after the intervention. The findings from this study suggest that FBCBSW is a promising approach to reducing elder abuse and warrants further study with larger samples.

  16. Weight Shame, Social Connection, and Depressive Symptoms in Late Adolescence.

    PubMed

    Brewis, Alexandra A; Bruening, Meg

    2018-05-01

    Child and adolescent obesity is increasingly the focus of interventions, because it predicts serious disease morbidity later in life. However, social environments that permit weight-related stigma and body shame may make weight control and loss more difficult. Rarely do youth obesity interventions address these complexities. Drawing on repeated measures in a large sample ( N = 1443) of first-year (freshman), campus-resident university students across a nine-month period, we model how weight-related shame predicts depressive symptom levels, how being overweight (assessed by anthropometric measures) shapes that risk, and how social connection (openness to friendship) might mediate/moderate. Body shame directly, clearly, and repeatedly predicts depression symptom levels across the whole school year for all students, but overweight youth have significantly elevated risk. Social connections mediate earlier in the school year, and in all phases moderate, body shame effects on depression. Youth obesity interventions would be well-served recognizing and incorporating the influential roles of social-environmental factors like weight stigma and friendship in program design.

  17. ICAO helicopter noise measurement repeatability program : U.S. test report, Bell 206L-1, noise measurement flight test

    DOT National Transportation Integrated Search

    1985-09-30

    This document reports the findings of the U.S. test team's participation in the Helicopter Noise Measurement Repeatability Program (HNMRP) conducted under the direction of the International Civil Aviation Organization's (ICAO) Committee on Aviation E...

  18. The Effect of Antiretroviral Combination Treatment on Epstein-Barr Virus (EBV) Genome Load in HIV-Infected Patients

    PubMed Central

    Friis, Anna M. C.; Gyllensten, Katarina; Aleman, Anna; Ernberg, Ingemar; Åkerlund, Börje

    2010-01-01

    We evaluated the effect of combination anti-retroviral treatment (cART) on the host control of EBV infection in moderately immunosuppressed HIV-1 patients. Twenty HIV-1 infected individuals were followed for five years with repeated measurements of EBV DNA load in peripheral blood lymphocytes in relation to HIV-RNA titers and CD4+ cell counts. Individuals with optimal response, i.e. durable non-detectable HIV-RNA, showed a decline of EBV load to the level of healthy controls. Individuals with non-optimal HIV-1 control did not restore their EBV control. Long-lasting suppression of HIV-replication after early initiation of cART is a prerequisite for re-establishing the immune control of EBV. PMID:21994658

  19. Effect of repeated forearm muscle cooling on the adaptation of skeletal muscle metabolism in humans

    NASA Astrophysics Data System (ADS)

    Wakabayashi, Hitoshi; Nishimura, Takayuki; Wijayanto, Titis; Watanuki, Shigeki; Tochihara, Yutaka

    2017-07-01

    This study aimed to investigate the effect of repeated cooling of forearm muscle on adaptation in skeletal muscle metabolism. It is hypothesized that repeated decreases of muscle temperature would increase the oxygen consumption in hypothermic skeletal muscle. Sixteen healthy males participated in this study. Their right forearm muscles were locally cooled to 25 °C by cooling pads attached to the skin. This local cooling was repeated eight times on separate days for eight participants (experimental group), whereas eight controls received no cold exposure. To evaluate adaptation in skeletal muscle metabolism, a local cooling test was conducted before and after the repeated cooling period. Change in oxy-hemoglobin content in the flexor digitorum at rest and during a 25-s isometric handgrip (10% maximal voluntary construction) was measured using near-infrared spectroscopy at every 2 °C reduction in forearm muscle temperature. The arterial blood flow was occluded for 15 s by upper arm cuff inflation at rest and during the isometric handgrip. The oxygen consumption in the flexor digitorum muscle was evaluated by a slope of the oxy-hemoglobin change during the arterial occlusion. In the experimental group, resting oxygen consumption in skeletal muscle did not show any difference between pre- and post-intervention, whereas muscle oxygen consumption during the isometric handgrip was significantly higher in post-intervention than in pre-test from thermoneutral baseline to 31 °C muscle temperature ( P < 0.05). This result indicated that repeated local muscle cooling might facilitate oxidative metabolism in the skeletal muscle. In summary, skeletal muscle metabolism during submaximal isometric handgrip was facilitated after repeated local muscle cooling.

  20. Effect of repeated forearm muscle cooling on the adaptation of skeletal muscle metabolism in humans.

    PubMed

    Wakabayashi, Hitoshi; Nishimura, Takayuki; Wijayanto, Titis; Watanuki, Shigeki; Tochihara, Yutaka

    2017-07-01

    This study aimed to investigate the effect of repeated cooling of forearm muscle on adaptation in skeletal muscle metabolism. It is hypothesized that repeated decreases of muscle temperature would increase the oxygen consumption in hypothermic skeletal muscle. Sixteen healthy males participated in this study. Their right forearm muscles were locally cooled to 25 °C by cooling pads attached to the skin. This local cooling was repeated eight times on separate days for eight participants (experimental group), whereas eight controls received no cold exposure. To evaluate adaptation in skeletal muscle metabolism, a local cooling test was conducted before and after the repeated cooling period. Change in oxy-hemoglobin content in the flexor digitorum at rest and during a 25-s isometric handgrip (10% maximal voluntary construction) was measured using near-infrared spectroscopy at every 2 °C reduction in forearm muscle temperature. The arterial blood flow was occluded for 15 s by upper arm cuff inflation at rest and during the isometric handgrip. The oxygen consumption in the flexor digitorum muscle was evaluated by a slope of the oxy-hemoglobin change during the arterial occlusion. In the experimental group, resting oxygen consumption in skeletal muscle did not show any difference between pre- and post-intervention, whereas muscle oxygen consumption during the isometric handgrip was significantly higher in post-intervention than in pre-test from thermoneutral baseline to 31 °C muscle temperature (P < 0.05). This result indicated that repeated local muscle cooling might facilitate oxidative metabolism in the skeletal muscle. In summary, skeletal muscle metabolism during submaximal isometric handgrip was facilitated after repeated local muscle cooling.

  1. Approximate analysis for repeated eigenvalue problems with applications to controls-structure integrated design

    NASA Technical Reports Server (NTRS)

    Kenny, Sean P.; Hou, Gene J. W.

    1994-01-01

    A method for eigenvalue and eigenvector approximate analysis for the case of repeated eigenvalues with distinct first derivatives is presented. The approximate analysis method developed involves a reparameterization of the multivariable structural eigenvalue problem in terms of a single positive-valued parameter. The resulting equations yield first-order approximations to changes in the eigenvalues and the eigenvectors associated with the repeated eigenvalue problem. This work also presents a numerical technique that facilitates the definition of an eigenvector derivative for the case of repeated eigenvalues with repeated eigenvalue derivatives (of all orders). Examples are given which demonstrate the application of such equations for sensitivity and approximate analysis. Emphasis is placed on the application of sensitivity analysis to large-scale structural and controls-structures optimization problems.

  2. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement.

    PubMed

    Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-06-01

    This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.

  3. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement

    PubMed Central

    Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-01-01

    Objective This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Methods Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. Results There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). Conclusion This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant. PMID:26741415

  4. Einstein-Podolsky-Rosen paradox implies a minimum achievable temperature

    NASA Astrophysics Data System (ADS)

    Rogers, David M.

    2017-01-01

    This work examines the thermodynamic consequences of the repeated partial projection model for coupling a quantum system to an arbitrary series of environments under feedback control. This paper provides observational definitions of heat and work that can be realized in current laboratory setups. In contrast to other definitions, it uses only properties of the environment and the measurement outcomes, avoiding references to the "measurement" of the central system's state in any basis. These definitions are consistent with the usual laws of thermodynamics at all temperatures, while never requiring complete projective measurement of the entire system. It is shown that the back action of measurement must be counted as work rather than heat to satisfy the second law. Comparisons are made to quantum jump (unravelling) and transition-probability based definitions, many of which appear as particular limits of the present model. These limits show that our total entropy production is a lower bound on traditional definitions of heat that trace out the measurement device. Examining the master equation approximation to the process at finite measurement rates, we show that most interactions with the environment make the system unable to reach absolute zero. We give an explicit formula for the minimum temperature achievable in repeatedly measured quantum systems. The phenomenon of minimum temperature offers an explanation of recent experiments aimed at testing fluctuation theorems in the quantum realm and places a fundamental purity limit on quantum computers.

  5. Magnetoresistance measurement of permalloy thin film rings with triangular fins

    NASA Astrophysics Data System (ADS)

    Lai, Mei-Feng; Hsu, Chia-Jung; Liao, Chun-Neng; Chen, Ying-Jiun; Wei, Zung-Hang

    2010-01-01

    Magnetization reversals in permalloy rings controlled by nucleation sites using triangular fins at the same side and diagonal with respect to the field direction are demonstrated by magnetoresistance measurement and micromagnetic simulation. In the ring with triangular fins at the same side, there exists two-step reversal from onion to flux-closure state (or vortex state) and then from flux-closure (or vortex state) to reverse onion state; in the ring with diagonal triangular fins, one-step reversal occurs directly from onion to reverse onion state. The reversal processes are repeatable and controllable in contrast to an ideal ring without triangular fins where one-step and two-step reversals occur randomly in sweep-up and sweep-down processes.

  6. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    PubMed

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  7. Therapeutic Magnets Do Not Affect Tissue Temperatures

    PubMed Central

    Sweeney, Kathleen B.; Ingersoll, Christopher D.; Swez, John A.

    2001-01-01

    Objective: Manufacturers of commercially available “therapeutic” magnets claim that these magnets cause physiologic thermal effects that promote tissue healing. We conducted this study to determine if skin or intramuscular temperatures differed among magnet, sham, and control treatments during 60 minutes of application to the quadriceps muscle. Design and Setting: A 3 × 3 mixed-model, factorial design with repeated measures on both independent variables was used. The first independent variable, application duration, had 3 random levels (20, 40, and 60 minutes). The second independent variable, treatment, had 3 fixed levels (magnet, sham, and control). The dependent variable was tissue temperature (°C). Measurement depth served as a control variable, with 2 levels: skin and 1 cm below the fat layer. Data were collected in a thermoneutral laboratory setting and analyzed using a repeated-measures analysis of variance. Subjects: The study included 13 healthy student volunteers (8 men, 5 women; age, 20.5 ± 0.9 years; height, 176.8 ± 10.4 cm; weight, 73.8 ± 11.8 kg; anterior thigh skinfold thickness, 16.9 ± 6.5 mm). Measurements: Temperatures were measured at 30-second intervals using surface and implantable thermocouples. Temperature data at 20, 40, and 60 minutes were used for analysis. Each subject received all 3 treatments on different days. Results: Neither skin nor intramuscular temperatures were different across the 3 treatments at any time. For both skin and intramuscular temperatures, a statistically significant but not clinically meaningful temperature increase (less than 1°C), was observed over time within treatments, but this increase was similar in all treatment groups. Conclusions: No meaningful thermal effect was observed with any treatment over time, and treatments did not differ from each other. We conclude that flexible therapeutic magnets were not effective for increasing skin or deep temperatures, contradicting one of the fundamental claims made by magnet distributors. PMID:12937511

  8. Affect-regulated exercise intensity: does training at an intensity that feels 'good' improve physical health?

    PubMed

    Parfitt, Gaynor; Alrumh, Amnah; Rowlands, Alex V

    2012-11-01

    Affect-regulated exercise to feel 'good' can be used to control exercise intensity amongst both active and sedentary individuals and should support exercise adherence. It is not known, however, whether affect-regulated exercise training can lead to physical health gains. The aim of this study was to examine if affect-regulated exercise to feel 'good' leads to improved fitness over the course of an 8-week training programme. A repeated measures design (pretest-posttest) with independent groups (training and control). 20 sedentary females completed a submaximal graded exercise test and were then allocated to either a training group or control group. The training group completed two supervised sessions and one unsupervised session per week for 8 weeks. Exercise intensity was affect-regulated to feel 'good'. Following the 8 weeks of training, both groups completed a second submaximal graded exercise test. Repeated measures analyses of variance indicated a significant increase in the time to reach ventilatory threshold in the training group (318 ± 23.7s) compared to control (248 ± 16.9s). Overall compliance to training was high (>92%). Participants in the training group exercised at intensities that would be classified as being in the lower range of the recommended guidelines (≈ 50% V˙O(2) max) for cardiovascular health. Affect-regulated exercise to feel 'good' can be used in a training programme to regulate exercise intensity. This approach led to a 19% increase in time to reach ventilatory threshold, which is indicative of improved fitness. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Vestibular Dysfunction after Subconcussive Head Impact

    PubMed Central

    Ma, Lei; Kawata, Keisuke; Tierney, Ryan; Jeka, John J.

    2017-01-01

    Abstract Current thinking views mild head impact (i.e., subconcussion) as an underrecognized phenomenon that has the ability to cause significant current and future detrimental neurological effects. Repeated mild impacts to the head, however, often display no observable behavioral deficits based on standard clinical tests, which may lack sensitivity. The current study investigates the effects of subconcussive impacts from soccer heading with innovative measures of vestibular function and walking stability in a pre- 0–2 h, post- 24 h post-heading repeated measures design. The heading group (n = 10) executed 10 headers with soccer balls projected at a velocity of 25 mph (11.2 m/sec) over 10 min. Subjects were evaluated 24 h before, immediately after, and 24 h after soccer heading with: the modified Balance Error Scoring System (mBESS); a walking stability task with visual feedback of trunk movement; and galvanic vestibular stimulation (GVS) while standing with eyes closed on foam. A control group (n = 10) followed the same protocol with no heading. The results showed significant decrease in trunk angle, leg angle gain, and center of mass gain relative to GVS for the heading group compared with controls. Medial-lateral trunk orientation displacement and velocity during treadmill walking increased immediately after mild head impact for the heading group compared with controls. Controls showed an improvement in mBESS scores over time, indicating a learning effect, which was not observed with the heading group. These results suggest that mild head impact leads to a transient dysfunction in vestibular processing, which deters walking stability during task performance. PMID:26885560

  10. Vestibular Dysfunction after Subconcussive Head Impact.

    PubMed

    Hwang, Sungjae; Ma, Lei; Kawata, Keisuke; Tierney, Ryan; Jeka, John J

    2017-01-01

    Current thinking views mild head impact (i.e., subconcussion) as an underrecognized phenomenon that has the ability to cause significant current and future detrimental neurological effects. Repeated mild impacts to the head, however, often display no observable behavioral deficits based on standard clinical tests, which may lack sensitivity. The current study investigates the effects of subconcussive impacts from soccer heading with innovative measures of vestibular function and walking stability in a pre- 0-2 h, post- 24 h post-heading repeated measures design. The heading group (n = 10) executed 10 headers with soccer balls projected at a velocity of 25 mph (11.2 m/sec) over 10 min. Subjects were evaluated 24 h before, immediately after, and 24 h after soccer heading with: the modified Balance Error Scoring System (mBESS); a walking stability task with visual feedback of trunk movement; and galvanic vestibular stimulation (GVS) while standing with eyes closed on foam. A control group (n = 10) followed the same protocol with no heading. The results showed significant decrease in trunk angle, leg angle gain, and center of mass gain relative to GVS for the heading group compared with controls. Medial-lateral trunk orientation displacement and velocity during treadmill walking increased immediately after mild head impact for the heading group compared with controls. Controls showed an improvement in mBESS scores over time, indicating a learning effect, which was not observed with the heading group. These results suggest that mild head impact leads to a transient dysfunction in vestibular processing, which deters walking stability during task performance.

  11. Comparing Acceptance and Commitment Group Therapy and 12-Steps Narcotics Anonymous in Addict's Rehabilitation Process: A Randomized Controlled Trial.

    PubMed

    Azkhosh, Manoochehr; Farhoudianm, Ali; Saadati, Hemn; Shoaee, Fateme; Lashani, Leila

    2016-10-01

    Objective: Substance abuse is a socio-psychological disorder. The aim of this study was to compare the effectiveness of acceptance and commitment therapy with 12-steps Narcotics Anonymous on psychological well-being of opiate dependent individuals in addiction treatment centers in Shiraz, Iran. Method: This was a randomized controlled trial. Data were collected at entry into the study and at post-test and follow-up visits. The participants were selected from opiate addicted individuals who referred to addiction treatment centers in Shiraz. Sixty individuals were evaluated according to inclusion/ exclusion criteria and were divided into three equal groups randomly (20 participants per group). One group received acceptance and commitment group therapy (Twelve 90-minute sessions) and the other group was provided with the 12-steps Narcotics Anonymous program and the control group received the usual methadone maintenance treatment. During the treatment process, seven participants dropped out. Data were collected using the psychological well-being questionnaire and AAQ questionnaire in the three groups at pre-test, post-test and follow-up visits. Data were analyzed using repeated measure analysis of variance. Results: Repeated measure analysis of variance revealed that the mean difference between the three groups was significant (P<0.05) and that acceptance and commitment therapy group showed improvement relative to the NA and control groups on psychological well-being and psychological flexibility. Conclusion : The results of this study revealed that acceptance and commitment therapy can be helpful in enhancing positive emotions and increasing psychological well-being of addicts who seek treatment.

  12. Using the Hand Laterality Judgement Task to Assess Motor Imagery: A Study of Practice Effects in Repeated Measurements

    ERIC Educational Resources Information Center

    Boonstra, Anne M.; de Vries, Sjoerd J.; Veenstra, Evelien; Tepper, Marga; Feenstra, Wya; Otten, Egbert

    2012-01-01

    The aim of this study was to determine whether there is a practice effect on the Hand Laterality Judgement Task (HLJT). The HLJT task is a mental rotation task that can be used to assess motor imagery ability in stroke patients. Thirty-three healthy individuals performed the HLJT and two control tasks twice at a 3-week interval. Differences in the…

  13. Officer Career Development: An Overview of Analytic Concerns

    DTIC Science & Technology

    1989-07-01

    some form of quasi-experimental analysis with nonequivalent control groups may be implemented. We shall not attempt to explic te all the variables...Development Center. 5. University of San Diego (1984, October 23-25). Pro z.ings: Volume I. Group reports. Tri-service career research workshop. San Die... design rather than a repeated measures design , where differences among diverse groups of different individuals (at different career stages) are used to

  14. A Preliminary Study of the Effects of Repeated Massage on Hypothalamic–Pituitary–Adrenal and Immune Function in Healthy Individuals: A Study of Mechanisms of Action and Dosage

    PubMed Central

    Schettler, Pamela; Bresee, Catherine

    2012-01-01

    Abstract Objectives This study gathers preliminary data about the biologic effects of repeated Swedish massage therapy compared to a light-touch control condition. Design The study design was a 5-week comparison of repeated Swedish massage and light touch on oxytocin (OT), arginine-vasopressin (AVP), adrenal corticotropin hormone (ACTH), cortisol (CORT), circulating phenotypic lymphocyte markers, and mitogen-stimulated cytokine function. Setting The setting was an outpatient research unit in an academic medical center. Participants The study subjects were medically and psychiatrically healthy young adults. Intervention The study comprised 45 minutes of Swedish massage or light touch, using highly specified and identical protocols, either weekly or twice weekly for 5 weeks. Outcome measures The outcome measures were mean differences between massage and light touch on OT, AVP, ACTH, CORT, lymphocyte markers, and cytokine levels. Results Compared to the touch control condition, weekly Swedish massage stimulated a sustained pattern of increased circulating phenotypic lymphocyte markers and decreased mitogen-stimulated cytokine production, similar to what was previously reported for a single massage session, while having minimal effect on hypothalamic–pituitary–adrenal function. Twice-weekly massage produced a different response pattern with increased OT levels, decreased AVP, and decreased CORT but little effect on circulating lymphocyte phenotypic markers and a slight increase in mitogen-stimulated interferon-γ, tumor necrosis factor-α, interleukin (IL)-1b and IL-2 levels, suggesting increased production of pro-inflammatory cytokines. Conclusions There are sustained cumulative biologic actions for the massage and touch interventions that persist for several days or a week, and these differ profoundly depending on the dosage (frequency) of sessions. Confirmatory studies in larger samples are needed. PMID:22775448

  15. The root of the problem: increasing root vegetable intake in preschool children by repeated exposure and flavour flavour learning.

    PubMed

    Ahern, Sara M; Caton, Samantha J; Blundell, Pam; Hetherington, Marion M

    2014-09-01

    Children's vegetable consumption falls below current recommendations, highlighting the need to identify strategies that can successfully promote intake. The current study aimed to investigate the effectiveness of flavour-flavour learning as one such strategy for increasing vegetable intake in preschool children. Children (N = 29) aged 15 to 56 months were recruited through participating nurseries. Each received a minimum of six and maximium eight exposures to a root vegetable puree with added apple puree (flavour-flavour learning) alternating with six to eight exposures to another with nothing added (repeated exposure). A third puree acted as a control. Pre- and post-intervention intake measures of the three purees with nothing added were taken to assess change in intake. Follow-up measures took place 1 month (n = 28) and 6 months (n = 10) post-intervention. Intake increased significantly from pre- to post-intervention for all purees (~36 g), with no effect of condition. Magnitude of change was smaller in the control condition. Analysis of follow-up data showed that intake remained significantly higher than baseline 1 month (p < 0.001) and 6 months (p < 0.001) post-intervention for all conditions. Children under 24 months ate consistently more across the intervention than the older children (≥24 m) with no differences found in response to condition. This study confirms previous observations that repeated exposure increases intake of a novel vegetable in young children. Results also suggest that mere exposure (to the food, the experimenters, the procedure) can generalise to other, similar vegetables but the addition of a familiar flavour confers no added advantage above mere exposure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Repeated stressor exposure enhances contextual fear memory in a beta-adrenergic receptor-dependent process and increases impulsivity in a non-beta receptor-dependent fashion.

    PubMed

    Camp, Robert M; Johnson, John D

    2015-10-15

    Memory formation is promoted by stress via the release of norepinephrine and stimulation of beta-adrenergic receptors (β-ARs). Previous data demonstrate that repeated stressor exposure increases norepinephrine turnover and β-AR signaling within the amygdala, which led to the hypothesis that some stress-induced behavioral changes are likely due to facilitated associative learning. To test this, Fischer rats were exposed to chronic mild stress for four days. On day 5, subjects (including non-stressed controls) were injected with the beta-blocker propranolol or vehicle prior to conditioning in an operant box (animals receive two mild foot shocks) or passive avoidance apparatus (animals received a foot shock upon entry into the dark chamber). Twenty-four hours later, subjects were returned to the operant box for measurement of freezing or returned to the passive avoidance apparatus for measurement of latency to enter the dark chamber. Subjects were also tested in an open field to assess context-independent anxiety-like behavior. Animals exposed to chronic stress showed significantly more freezing behavior in the operant box than did controls, and this exaggerated freezing was blocked by propranolol during the conditioning trial. There was no effect of stress on behavior in the open field. Unexpectedly, retention latency was significantly reduced in subjects exposed to chronic stress. These results indicate that chronic exposure to stress results in complex behavioral changes. While repeated stress appears to enhance the formation of fearful memories, it also results in behavioral responses that resemble impulsive behaviors that result in poor decision-making. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Escalation of cocaine self-administration in adulthood after social defeat of adolescent rats: Role of social experience and adaptive coping behavior

    PubMed Central

    Burke, Andrew R.; Miczek, Klaus A.

    2015-01-01

    Background The link between adolescent social stress and substance abuse is modeled in social defeat of adolescent male rats, at an age when social experiences are essential for neurobehavioral maturation. Objective We investigated the role of social experience and social defeat stress during adolescence on social behavior and cocaine self administration (CocSelfAd) in early adulthood. Methods We manipulated social experience by housing male rats in pairs (PH) or singly (SH) on postnatal day (P) 21. In addition, rats were subjected to social defeat from P35-44. Social behavior was measured during the first and last social defeat in PH and SH adolescents and PH adults. After assessing the behavioral response to novelty and cocaine (P57-61), intra-jugular catheters were implanted and CocSelfAd was analyzed. Results Residents were less aggressive toward PH adolescent intruders compared to PH adult intruders. Adults were submissive and defensive when attacked, whereas PH adolescents froze. In the course of repeated defeats, adolescent PH rats increased freezing, while SH rats decreased freezing. Longer attack-induced freezing after repeated defeats predicted escalated CocSelfAd in adulthood. PH controls acquired CocSelfAd more slowly than PH defeated and SH rats. Defeated PH rats increased CocSelfAd during progressive ratio schedules of reinforcement and during a 24-hour continuous access binge compared to PH controls and SH defeated rats. Conclusions Social defeat in adolescence of PH rats caused persistent increases in adult CocSelfAd. Adolescent PH rats coped with attacks adaptively by increasing freezing behavior after repeated social defeats, a measure that predicted CocSelfAd in adulthood. PMID:25943168

  18. Effects of High Frequency Repeated Transcranial Magnetic Stimulation and Continuous Theta Burst Stimulation on Gambling Reinforcement, Delay Discounting, and Stroop Interference in Men with Pathological Gambling.

    PubMed

    Zack, Martin; Cho, Sang Soo; Parlee, Jennifer; Jacobs, Mark; Li, Crystal; Boileau, Isabelle; Strafella, Antonio

    Repeated transcranial magnetic stimulation (rTMS) can reduce cravings and improve cognitive function in substance dependent individuals. Whether these benefits extend to individuals with pathological gambling (PG) is unclear. High-frequency rTMS of the medial prefrontal cortex (PFC) and continuous theta burst stimulation (cTBS) of the right dorsolateral PFC can reduce impulsive choice in healthy volunteers. This study aimed to assess the effects of these two protocols on gambling reinforcement and related responses in otherwise healthy men with PG. Participants (n = 9) underwent active or sham treatments at weekly intervals in a repeated-measures, Latin square design. Subjective and physiological responses were assessed before and after a 15-min slot machine game on each session. Delay discounting and Stroop tasks measured post-game impulsive choice and attentional control. Multivariate analysis of covariance, controlling for winnings on the slot machine under each treatment, found that rTMS reduced the post-game increase in Desire to Gamble; cTBS reduced amphetamine-like effects, and decreased diastolic blood pressure. Treatment had no significant univariate effects on bet size or speed of play in the game; however, a multivariate effect for the two indices suggested that treatment decreased behavioral activation. Neither treatment reduced impulsive choice, while both treatments increased Stroop interference. rTMS and cTBS can reduce gambling reinforcement in non-comorbid men with PG. Separate processes appear to mediate gambling reinforcement and betting behavior as against delay discounting and Stroop interference. Interventions that modify risky as opposed to temporal aspects of decision making may better predict therapeutic response in PG. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Predictive value of repeated measurements of luteal progesterone and estradiol levels in patients with intrauterine insemination and controlled ovarian stimulation.

    PubMed

    Bakas, Panagiotis; Simopoulou, Maria; Giner, Maria; Drakakis, Petros; Panagopoulos, Perikles; Vlahos, Nikolaos

    2017-10-01

    The objective of this study is to assess if the difference of repeated measurements of estradiol and progesterone during luteal phase predict the outcome of intrauterine insemination. Prospective study. Reproductive clinic. 126 patients with infertility. Patients underwent controlled ovarian stimulation with recombinant FSH (50-150 IU/d). The day of IUI patients were given p.o natural micronized progesterone in a dose of 100 mg/tds. The area under the receiver characteristic operating curve (ROC curve) in predicting clinical pregnancy for % change of estradiol level on days 6 and 10 was 0.892 with 95% CI: 0.82-0.94. A cutoff value of change > -29.5% had a sensitivity of 85.7 with a specificity of 90.2. The corresponding ROC curve for % change of progesterone level was 0.839 with 95% CI: 0.76-0.90. A cutoff value of change > -33% had a sensitivity of 85 with a specificity of 75. The % change of estradiol and progesterone between days 6 and 10 has a predictive ability of pregnancy after IUI with COS of 89.2% and 83.4%, respectively. The addition of % of progesterone to % change of estradiol does not improve the predictive ability of % estradiol and should not be used.

  20. The Impact of Brain Breaks Classroom-Based Physical Activities on Attitudes toward Physical Activity in Polish School Children in Third to Fifth Grade.

    PubMed

    Glapa, Agata; Grzesiak, Joanna; Laudanska-Krzeminska, Ida; Chin, Ming-Kai; Edginton, Christopher R; Mok, Magdalena Mo Ching; Bronikowski, Michal

    2018-02-21

    The purpose of this study was to examine the effectiveness of the Brain Breaks® Physical Activity Solutions in changing attitudes toward physical activity of school children in a community in Poland. In 2015, a sample of 326 pupils aged 9-11 years old from 19 classes at three selected primary schools were randomly assigned to control and experimental groups within the study. During the classes, children in the experimental group performed physical activities two times per day in three to five minutes using Brain Breaks® videos for four months, while the control group did not use the videos during the test period. Students' attitudes toward physical activities were assessed before and after the intervention using the "Attitudes toward Physical Activity Scale". Repeated measures of ANOVA were used to examine the change from pre- to post-intervention. Overall, a repeated measures ANOVA indicated time-by-group interaction effects in 'Self-efficacy on learning with video exercises', F(1.32) = 75.28, p = 0.00, η2 = 0.19. Although the changes are minor, there were benefits of the intervention. It may be concluded that HOPSports Brain Breaks® Physical Activity Program contributes to better self-efficacy on learning while using video exercise of primary school children.

  1. [Establishment of enzyme-linked immunosorbent assay (ELISA) for measuring human urinary uromodulin and application of the method in patients with IgA nephropathy].

    PubMed

    Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong

    2012-04-18

    To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.

  2. Effects of a Brief Empowerment Program for Families of Persons with Mental Illness in South Korea: A Pilot Study.

    PubMed

    Hyun, Myung-Sun; Nam, Kyoung A; Kim, Hyunlye

    2018-05-30

    Families of persons with mental illness (PMIs) are considered important resources for PMIs rather than as contributors to their mental illness. However, these families experience not only the burden of caregiving but also social stigma and discrimination in various aspects of their lives, and their psychosocial needs tend to be overlooked. This was a pilot study to explore the effects of a brief empowerment program on the empowerment and quality of life of families of PMIs in South Korea. A repeated-measures design with a control group and pre/post-follow-up testing was used. We enrolled 18 participants (experimental group = 9, control group = 9). The experimental group participated in an empowerment program consisting of four sessions over 4 weeks. Data were collected before and after the program, and again 4 weeks later. The χ 2 -test, Fisher's exact probability test, t-test, and repeated-measures analysis of covariance were used, as appropriate, to analyze data. The program significantly increased empowerment (F = 4.66, p = .020) and quality of life (F = 5.83, p = .009) among participants in the experimental group over time. Its therapeutic features, such as sharing their experiences, discussion, and presentations, can be applied to create effective psychosocial interventions for families of PMIs.

  3. Effects of a Family-based Diabetes Intervention on Behavioral and Biological Outcomes for Mexican American Adults.

    PubMed

    McEwen, Marylyn Morris; Pasvogel, Alice; Murdaugh, Carolyn; Hepworth, Joseph

    2017-06-01

    Purpose The purpose of the study was to investigate the effects of a family-based self-management support intervention for adults with type 2 diabetes (T2DM). Methods Using a 2-group, experimental repeated measures design, 157 dyads (participant with T2DM and family member) were randomly assigned to an intervention (education, social support, home visits, and telephone calls) or a wait list control group. Data were collected at baseline, postintervention (3 months), and 6 months postintervention. A series of 2 × 3 repeated measures ANOVAs were used to test the hypotheses with interaction contrasts to assess immediate and sustained intervention effects. Results Significant changes over time were reported in diet self-management, exercise self-management, total self-management, diabetes self-efficacy for general health and total diabetes self-efficacy, physician distress, regimen distress, interpersonal distress, and total distress. There were likewise sustained effects for diet self-management, total self-management, diabetes self-efficacy for general health, total self-efficacy, physician distress, regimen distress, and interpersonal distress. Conclusions Results support and extend prior research documenting the value of culturally relevant family-based interventions to improve diabetes self-management and substantiate the need for intensive, longer, tailored interventions to achieve glycemic control.

  4. Relationship disruption stress in human infants: a validation study with experimental and control groups.

    PubMed

    Haley, David W

    2011-09-01

    The current study examined whether the psychological stress of the still-face (SF) task (i.e. stress resulting from a parent's unresponsiveness) is a valid laboratory stress paradigm for evaluating infant cortisol reactivity. Given that factors external to the experimental paradigm, such as arriving at a new place, may cause an elevation in cortisol secretion; we tested the hypothesis that infants would show a cortisol response to the SF task but not to a normal FF task (control). Saliva was collected for cortisol measurement from 6-month-old infants (n = 31) randomly assigned to either a repeated SF task or to a continuous FF task. Parent-infant dyads were videotaped. Salivary cortisol concentration was measured at baseline, 20, and 30 min after the start of the procedure. Infant salivary cortisol concentrations showed a significant increase over time for the SF task but not for the FF task. The results provide new evidence that the repeated SF task provides a psychological challenge that is due to the SF condition rather than to some non-task related factor; these results provide internal validity for the paradigm. The study offers new insight into the role of parent-infant interactions in the activation of the infant stress response system.

  5. Discontinuous Patterns of Brain Activation in the Psychotherapy Process of Obsessive-Compulsive Disorder: Converging Results from Repeated fMRI and Daily Self-Reports

    PubMed Central

    Schiepek, Günter; Tominschek, Igor; Heinzel, Stephan; Aigner, Martin; Dold, Markus; Unger, Annemarie; Lenz, Gerhard; Windischberger, Christian; Moser, Ewald; Plöderl, Martin; Lutz, Jürgen; Meindl, Thomas; Zaudig, Michael; Pogarell, Oliver; Karch, Susanne

    2013-01-01

    This study investigates neuronal activation patterns during the psychotherapeutic process, assuming that change dynamics undergo critical instabilities and discontinuous transitions. An internet-based system was used to collect daily self-assessments during inpatient therapies. A dynamic complexity measure was applied to the resulting time series. Critical phases of the change process were indicated by the maxima of the varying complexity. Repeated functional magnetic resonance imaging (fMRI) measurements were conducted over the course of the therapy. The study was realized with 9 patients suffering from obsessive-compulsive disorder (subtype: washing/contamination fear) and 9 matched healthy controls. For symptom-provocative stimulation individualized pictures from patients’ personal environments were used. The neuronal responses to these disease-specific pictures were compared to the responses during standardized disgust-provoking and neutral pictures. Considerably larger neuronal changes in therapy-relevant brain areas (cingulate cortex/supplementary motor cortex, bilateral dorsolateral prefrontal cortex, bilateral insula, bilateral parietal cortex, cuneus) were observed during critical phases (order transitions), as compared to non-critical phases, and also compared to healthy controls. The data indicate that non-stationary changes play a crucial role in the psychotherapeutic process supporting self-organization and complexity models of therapeutic change. PMID:23977168

  6. Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

    PubMed

    Forooghian, Farzin; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T

    2008-10-01

    To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular subfields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CR(W)), and coefficients of variation (CV(W)) were used to assess intrasession repeatability. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 microm and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CR(W), CV(W), and ICC. Repeatability measures (CR(W) and CV(W)) differed significantly between systems in only one of nine subfields (outer temporal subfield). Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.

  7. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    PubMed

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care.

  8. Maintaining confidentiality in prospective studies: anonymous repeated measurements via email (ARME) procedure.

    PubMed

    Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta

    2012-02-01

    Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.

  9. Variability in objective and subjective measures affects baseline values in studies of patients with COPD

    PubMed Central

    Ha, Jae Wook; Couper, David J.; O’Neal, Wanda K.; Barr, R. Graham; Bleecker, Eugene R.; Carretta, Elizabeth E.; Cooper, Christopher B.; Doerschuk, Claire M.; Drummond, M Bradley; Han, MeiLan K.; Hansel, Nadia N.; Kim, Victor; Kleerup, Eric C.; Martinez, Fernando J.; Rennard, Stephen I.; Tashkin, Donald; Woodruff, Prescott G.; Paine, Robert; Curtis, Jeffrey L.; Kanner, Richard E.

    2017-01-01

    Rationale Understanding the reliability and repeatability of clinical measurements used in the diagnosis, treatment and monitoring of disease progression is of critical importance across all disciplines of clinical practice and in clinical trials to assess therapeutic efficacy and safety. Objectives Our goal is to understand normal variability for assessing true changes in health status and to more accurately utilize this data to differentiate disease characteristics and outcomes. Methods Our study is the first study designed entirely to establish the repeatability of a large number of instruments utilized for the clinical assessment of COPD in the same subjects over the same period. We utilized SPIROMICS participants (n = 98) that returned to their clinical center within 6 weeks of their baseline visit to repeat complete baseline assessments. Demographics, spirometry, questionnaires, complete blood cell counts (CBC), medical history, and emphysema status by computerized tomography (CT) imaging were obtained. Results Pulmonary function tests (PFTs) were highly repeatable (ICC’s >0.9) but the 6 minute walk (6MW) was less so (ICC = 0.79). Among questionnaires, the Saint George’s Respiratory Questionnaire (SGRQ) was most repeatable. Self-reported clinical features, such as exacerbation history, and features of chronic bronchitis, often produced kappa values <0.6. Reported age at starting smoking and average number of cigarettes smoked were modestly repeatable (kappa = 0.76 and 0.79). Complete blood counts (CBC) variables produced intraclass correlation coefficients (ICC) values between 0.6 and 0.8. Conclusions PFTs were highly repeatable, while subjective measures and subject recall were more variable. Analyses using features with poor repeatability could lead to misclassification and outcome errors. Hence, care should be taken when interpreting change in clinical features based on measures with low repeatability. Efforts to improve repeatability of key clinical features such as exacerbation history and chronic bronchitis are warranted. PMID:28934249

  10. Anthropometry in Klinefelter syndrome--multifactorial influences due to CAG length, testosterone treatment and possibly intrauterine hypogonadism.

    PubMed

    Chang, Simon; Skakkebæk, Anne; Trolle, Christian; Bojesen, Anders; Hertz, Jens Michael; Cohen, Arieh; Hougaard, David Michael; Wallentin, Mikkel; Pedersen, Anders Degn; Østergaard, John Rosendahl; Gravholt, Claus Højbjerg

    2015-03-01

    Klinefelter syndrome, 47, XXY (KS), is underdiagnosed partly due to few clinical signs complicating identification of affected individuals. Certain phenotypic traits are common in KS. However, not all aspects of the KS phenotype are well described. To describe anthropometry and body composition in KS and relate findings to biochemistry and X-chromosome related genetic markers. Seventy three KS males referred to our clinic and 73 age-matched controls underwent comprehensive measurements of anthropometry and body composition in a cross-sectional, case-controlled study. Furthermore, genetic analysis for parental origin of the supernumerary X-chromosome, skewed X-chromosome inactivation and androgen receptor (AR) CAG repeat length was done. Anthropometry and body composition in KS and the effect of genotype hereon. KS males were taller (absolute difference: 5.1 cm, P < .001) with longer legs (5.7 cm, P < .001) compared with controls. Furthermore, 2D:4D was increased in KS males (relative effect size: Cohen's d = 0.40), reflecting reduced fetal testosterone exposure. Also, bi-iliac width (0.41), waist (0.52), and hip circumference (0.47) (P < .02 for all), as well as total fat mass (0.74), abdominal fat mass (0.67), and total body fat percentage (0.84) was increased in KS males (P < .001 for all), while bitesticular volume was reduced (4.6). AR CAG repeat length was comparable in KS and controls, and among KS CAG correlated to arm length (P = .04), arm span (P = .01), and leg length (P = .04). Effects of parental origin of the supernumerary X-chromosome and skewed X-chromosome inactivation were negligible. Anthropometry and body composition in KS is specific and dysmorphic and affected by AR CAG repeat length and decreased exposure to testosterone already during fetal life.

  11. Waning of "conditioned pain modulation": a novel expression of subtle pronociception in migraine.

    PubMed

    Nahman-Averbuch, Hadas; Granovsky, Yelena; Coghill, Robert C; Yarnitsky, David; Sprecher, Elliot; Weissman-Fogel, Irit

    2013-01-01

    To assess the decay of the conditioned pain modulation (CPM) response along repeated applications as a possible expression of subtle pronociception in migraine. One of the most explored mechanisms underlying the pain modulation system is "diffuse noxious inhibitory controls," which is measured psychophysically in the lab by the CPM paradigm. There are contradicting reports on CPM response in migraine, questioning whether migraineurs express pronociceptive pain modulation. Migraineurs (n = 26) and healthy controls (n = 35), all females, underwent 3 stimulation series, consisting of repeated (1) "test-stimulus" (Ts) alone that was given first followed by (2) parallel CPM application (CPM-parallel), and (3) sequential CPM application (CPM-sequential), in which the Ts is delivered during or following the conditioning-stimulus, respectively. In all series, the Ts repeated 4 times (0-3). In the CPM series, repetition "0" consisted of the Ts-alone that was followed by 3 repetitions of the Ts with a conditioning-stimulus application. Although there was no difference between migraineurs and controls for the first CPM response in each series, we found waning of CPM-parallel efficiency along the series for migraineurs (P = .005 for third vs first CPM), but not for controls. Further, greater CPM waning in the CPM-sequential series was correlated with less reported extent of pain reduction by episodic medication (r = 0.493, P = .028). Migraineurs have subtle deficits in endogenous pain modulation which requires a more challenging test protocol than the commonly used single CPM. Waning of CPM response seems to reveal this pronociceptive state. The clinical relevance of the CPM waning effect is highlighted by its association with clinical parameters of migraine. © 2013 American Headache Society.

  12. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    PubMed

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.

  13. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    PubMed

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J

    2016-01-01

    Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training.

  14. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability

    PubMed Central

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J.

    2016-01-01

    Background Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Methods Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. Results All criteria for feasibility were achieved. Mean V′O2peak was 106±9% of predicted V′O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V′O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). Conclusions RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training. PMID:26849137

  15. Electroencephalogram power changes as a correlate of chemotherapy-associated fatigue and cognitive dysfunction.

    PubMed

    Moore, Halle C F; Parsons, Michael W; Yue, Guang H; Rybicki, Lisa A; Siemionow, Wlodzimierz

    2014-08-01

    Persistent fatigue and cognitive dysfunction are poorly understood potential long-term effects of adjuvant chemotherapy. In this pilot study, we assessed the value of electroencephalogram (EEG) power measurements as a means to evaluate physical and mental fatigue associated with chemotherapy. Women planning to undergo adjuvant chemotherapy for breast cancer and healthy controls underwent neurophysiologic assessments at baseline, during the time of chemotherapy treatment, and at 1 year. Repeated measures analysis of variance was used to analyze the data. Compared with controls, patients reported more subjective fatigue at baseline that increased during chemotherapy and did not entirely resolve by 1 year. Performance on endurance testing was similar in patients versus controls at all time points; however, values of EEG power increased after a physical task in patients during chemotherapy but not controls. Compared with controls, subjective mental fatigue was similar for patients at baseline and 1 year but worsened during chemotherapy. Patients performed similarly to controls on formal cognitive testing at all time points, but EEG activity after the cognitive task was increased in patients only during chemotherapy. EEG power measurement has the potential to provide a sensitive neurophysiologic correlate of cancer treatment-related fatigue and cognitive dysfunction.

  16. Validation of a 3D CT method for measurement of linear wear of acetabular cups

    PubMed Central

    2011-01-01

    Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy. PMID:21281259

  17. Effect Sizes and their Intervals: The Two-Level Repeated Measures Case

    ERIC Educational Resources Information Center

    Algina, James; Keselman, H. J.; Penfield, Randall D.

    2005-01-01

    Probability coverage for eight different confidence intervals (CIs) of measures of effect size (ES) in a two-level repeated measures design was investigated. The CIs and measures of ES differed with regard to whether they used least squares or robust estimates of central tendency and variability, whether the end critical points of the interval…

  18. A Repeated Power Training Enhances Fatigue Resistance While Reducing Intraset Fluctuations.

    PubMed

    Gonzalo-Skok, Oliver; Tous-Fajardo, Julio; Moras, Gerard; Arjol-Serrano, José Luis; Mendez-Villanueva, Alberto

    2018-04-04

    Oliver, GS, Julio, TF, Moras, G, José Luis, AS, and Alberto, MV. A repeated power training enhances fatigue resistance while reducing intraset fluctuations. J Strength Cond Res XX(X): 000-000, 2018-The present study analyzed the effects of adding an upper-body repeated power ability (RPA) training to habitual strength training sessions. Twenty young elite male basketball players were randomly allocated into a control group (CON, n = 10) or repeated power group (RPG, n = 10) and evaluated by 1 repetition maximum (1RM), incremental load, and RPA tests in the bench press exercise before and after a 7-week period and a 4-week cessation period. Repeated power group performed 1-3 blocks of 5 sets of 5 repetitions using the load that maximized power output with 30 seconds and 3 minute of passive recovery between sets and blocks, respectively. Between-group analysis showed substantial greater improvements in RPG compared with CON in: best set (APB), last set (APL), mean power over 5 sets (APM), percentage of decrement, fluctuation decrease during APL and RPA index (APLpost/APBpre) during the RPA test (effect size [ES] = 0.64-1.86), and 1RM (ES = 0.48) and average power at 80% of 1RM (ES = 1.11) in the incremental load test. The improvements of APB and APM were almost perfectly correlated. In conclusion, RPA training represents an effective method to mainly improve fatigue resistance together with the novel finding of a better consistency in performance (measured as reduced intraset power fluctuations) at the end of a dynamic repeated effort.

  19. Development and intra-institutional and inter-institutional validation of a comprehensive new hepatobiliary software: Part 1--Liver and gallbladder function.

    PubMed

    Krishnamurthy, Gerbail T; Krishnamurthy, Shakuntala; Gambhir, Sanjiv Sam; Rodrigues, Cesar; Rosenberg, Jarrett; Schiepers, Christiaan; Buxton-Thomas, Muriel

    2009-12-01

    To develop a software tool for quantification of liver and gallbladder function, and to assess the repeatability and reproducibility of measurements made with it. The software tool developed with the JAVA programming language uses the JAVA2 Standard Edition framework. After manual selection of the regions of interest on a 99mTc hepatic iminodiacetic acid study, the program calculates differential hepatic bile flow, basal duodeno-gastric bile reflux (B-DGBR), hepatic extraction fraction (HEF) of both the lobes with deconvolutional analysis and excretion half-time with nonlinear least squares fit. Gallbladder ejection fraction, ejection period (EP), ejection rate (ER), and postcholecystokinin (CCK) DGBR are calculated after stimulation with CCK-8. To assess intra-observer repeatability and intra-observer reproducibility, measurements from 10 normal participants were analyzed twice by three nuclear medicine technologists at the primary center. To assess inter-site reproducibility, measurements from a superset of 24 normal participants were also assessed once by three observers at the primary center and single observer at three other sites. For the 24 control participants, mean+/-SD of hepatic bile flow into gallbladder was 63.87+/-28.7%, HEF of the right lobe 100+/-0%, left lobe 99.43+2.63%, excretion half-time of the right lobe 21.50+6.98 min, left lobe 28.3+/-11.3 min. Basal DGBR was 1.2+/-1.0%. Gallbladder ejection fraction was 80+/-11%, EP 15.0+/-3.0 min, ER 5.8+/-1.6%/min, and DGBR-CCK 1.3+/-2.3%. Left and right lobe HEF was virtually identical across readers. All measures showed high repeatability except for gallbladder bile flow, basal DGBR, and EP, which exhibited marginal repeatability. Ejection fraction exhibited high reproducibility. There was high concordance among the three primary center observers except for basal DGBR, EP, and ER. Concordance between the primary site and one of the other sites was high, one was fair, and one was poor. New United States Food and Drug Administration-approved personal computer-based Krishnamurthy Hepato-Biliary Software for quantification of the liver and gallbladder function shows promise for consistently repeatable and reproducible results both within and between institutions, and may help to promote universal standardization of data acquisition and analysis in nuclear hepatology.

  20. Reflexology has an acute (immediate) haemodynamic effect in healthy volunteers: a double-blind randomised controlled trial.

    PubMed

    Jones, Jenny; Thomson, Patricia; Lauder, William; Howie, Kate; Leslie, Stephen J

    2012-11-01

    Reflexologists claim that massage to specific points of the feet increases blood supply to internal organs. This study measured changes in cardiovascular parameters in subjects receiving reflexology to areas of their feet thought to correspond to the heart (intervention) compared with other areas which are not (control). 16 reflexology-naive healthy volunteers received an active and control reflexology treatment in an RCT, double-blind repeated measures study. 'Beat-to-beat' continuous measurement of selected cardiovascular parameters, State Anxiety Inventory. Cardiac index decreased significantly in the intervention group during left foot treatment (LFT) (baseline mean 2.6; standard deviation (SD) 0.75; 95% CI ± 0.38 vs. LFT mean 2.45; SD 0.68; CI 0.35), effect size (p = 0.035, omega squared effect (w2) = 0.002; w = 0.045). Reflexology massage applied to the upper part of the left foot may have a modest specific effect on the cardiac index of healthy volunteers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Effects of Group-Focused Cognitive-Behavioral Coaching Program on Depressive Symptoms in a Sample of Inmates in a Nigerian Prison.

    PubMed

    Eseadi, Chiedu; Obidoa, Mabel A; Ogbuabor, Shulamite E; Ikechukwu-Ilomuanya, Amaka B

    2018-05-01

    This study investigated the effects that a group-focused cognitive-behavioral coaching program had on depressive symptoms of a sample of inmates from Nsukka Prisons, Enugu State, Nigeria. The design of the study was pretest-posttest control group . The participants were 30 male inmates, experiencing high levels of depressive symptoms, and randomly assigned to treatment and control groups. The primary outcome measure was depression symptoms as measured using Beck's Depression Inventory. Repeated-measures ANOVA and the Mann-Whitney U Test were used for data analysis. Results show that exposing inmates to the group-focused cognitive-behavioral coaching program significantly reduced the depressive symptoms of inmates in the treatment group compared with those in the control group. Our results support the use of cognitive-behavioral coaching interventions designed to assist the severely depressed inmates in Nigeria. Further studies should be conducted both in other states of Nigeria and in other countries.

  2. Effects of Stress and Social Enrichment on Alcohol Intake, Biological and Psychological Stress Responses in Rats

    DTIC Science & Technology

    2010-06-28

    Variance (ANOVA) Table for Serum Corticosterone Table 15 – Repeated-Measures ANOVA Table for Body Weight, Within-Subject Effects Table 16...Serum Ethanol Concentration Table 21 – Repeated-Measures ANOVA Table for Rotarod Performance, Within- Subject Effects Table 22 – Repeated...and that this social environment seems to attenuate the effects of predator and unpredictable stressors on serum corticosterone . In summary, stressed

  3. Combustion process science and technology

    NASA Technical Reports Server (NTRS)

    Hale, Robert R.

    1989-01-01

    An important and substantial area of technical work in which noncontact temperature measurement (NCTM) is desired is that involving combustion process research. In the planning for this workshop, it was hoped that W. Serignano would provide a briefing regarding the experimental requirements for thermal measurements to support such research. The particular features of thermal measurement requirements included those describing the timeline for combustion experiments, the requirements for thermal control and diagnostics of temperature and other related thermal measurements and the criticality to the involved science to parametric features of measurement capability including precision, repeatability, stability, and resolution. In addition, it was hoped that definitions could be provided which characterize the needs for concurrent imaging as it relates to science observations during the conduct of experimentation.

  4. Effects of iterative learning based signal control strategies on macroscopic fundamental diagrams of urban road networks

    NASA Astrophysics Data System (ADS)

    Yan, Fei; Tian, Fuli; Shi, Zhongke

    2016-10-01

    Urban traffic flows are inherently repeated on a daily or weekly basis. This repeatability can help improve the traffic conditions if it is used properly by the control system. In this paper, we propose a novel iterative learning control (ILC) strategy for traffic signals of urban road networks using the repeatability feature of traffic flow. To improve the control robustness, the ILC strategy is further integrated with an error feedback control law in a complementary manner. Theoretical analysis indicates that the ILC-based traffic signal control methods can guarantee the asymptotic learning convergence, despite the presence of modeling uncertainties and exogenous disturbances. Finally, the impacts of the ILC-based signal control strategies on the network macroscopic fundamental diagram (MFD) are examined. The results show that the proposed ILC-based control strategies can homogenously distribute the network accumulation by controlling the vehicle numbers in each link to the desired levels under different traffic demands, which can result in the network with high capacity and mobility.

  5. Automatic-repeat-request error control schemes

    NASA Technical Reports Server (NTRS)

    Lin, S.; Costello, D. J., Jr.; Miller, M. J.

    1983-01-01

    Error detection incorporated with automatic-repeat-request (ARQ) is widely used for error control in data communication systems. This method of error control is simple and provides high system reliability. If a properly chosen code is used for error detection, virtually error-free data transmission can be attained. Various types of ARQ and hybrid ARQ schemes, and error detection using linear block codes are surveyed.

  6. Exposure to repeated immobilization stress inhibits cocaine-induced increase in dopamine extracellular levels in the rat ventral tegmental area.

    PubMed

    Sotomayor-Zárate, Ramón; Abarca, Jorge; Araya, Katherine A; Renard, Georgina M; Andrés, María E; Gysling, Katia

    2015-11-01

    A higher vulnerability to drug abuse has been observed in human studies of individuals exposed to chronic or persistent stress, as well as in animal models of drug abuse. Here, we explored the effect of repeated immobilization stress on cocaine-induced increase in dopamine extracellular levels in VTA and its regulation by corticotropin-releasing factor (CRF) and GABA systems. Cocaine (10mg/Kg i.p.) induced an increase of VTA DA extracellular levels in control rats. However, this effect was not observed in repeated stress rats. Considering the evidence relating stress with CRF, we decided to perfuse CRF and CP-154526 (selective antagonist of CRF1 receptor) in the VTA of control and repeated stress rats, respectively. We observed that perfusion of 20μM CRF inhibited the increase of VTA DA extracellular levels induced by cocaine in control rats. Interestingly, we observed that in the presence of 10μM CP-154526, cocaine induced a significant increase of VTA DA extracellular levels in repeated stress rats. Regarding the role of VTA GABA neurotransmission, cocaine administration induced a significant increase in VTA GABA extracellular levels only in repeated stress rats. Consistently, cocaine was able to increase VTA DA extracellular levels in repeated stress rats when 100μM bicuculline, an antagonist of GABAA receptor, was perfused intra VTA. Thus, both CRF and GABA systems are involved in the lack of response to cocaine in the VTA of repeated stress rats. It is tempting to suggest that the loss of response in VTA dopaminergic neurons to cocaine, after repeated stress, is due to an interaction between CRF and GABA systems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Using one-dimensional waveguide resonators to measure phase velocities in bubbly liquids.

    PubMed

    Dolder, Craig N; Wilson, Preston S

    2017-04-01

    Resonator techniques can be successfully used to extract effective medium properties from dispersive materials. However, in some cases the dispersion can cause modes to repeat. If repeated modes are not taken into account, the useful range of the resonator technique is limited. A resonance tube containing tethered balloons is used to create a dispersive effective medium. Resonator measurements show that modes do repeat. Direct measurement of the mode shapes allows exploitation of all longitudinal radially symmetric modes and expands the frequency range of the technique. A theoretical model is also used to predict when modes repeat. For the presented data set this method increases the measurement range from below 160 Hz to 3000 Hz excluding the stop band where resonances are damped. A means to account for non-ideal resonator boundary conditions often found in highly dispersive systems is discussed.

  8. Effects of exercise-based cardiac rehabilitation in patients after percutaneous coronary intervention: A meta-analysis of randomized controlled trials

    PubMed Central

    Yang, Xinyu; Li, Yanda; Ren, Xiaomeng; Xiong, Xingjiang; Wu, Lijun; Li, Jie; Wang, Jie; Gao, Yonghong; Shang, Hongcai; Xing, Yanwei

    2017-01-01

    In this study, we assessed the effect of rehabilitation exercise after percutaneous coronary intervention (PCI) in patients with coronary heart disease (CHD). We performed a meta-analysis to determine the effects of exercise in patients after PCI. The Cochrane Central Register of Controlled Trials (CENTRAL), PubMed, the Embase database, China National Knowledge Internet (CNKI), China Biology Medicine (CBM), and the Wanfang Database were searched for randomized controlled trials (RCTs). The key words used for the searches were PCI, exercise, walking, jogging, Tai Chi, and yoga. Six studies with 682 patients met our inclusion criteria; we chose the primary endpoint events of cardiac death, recurrence of myocardial infarction (MI), repeated PCI, coronary artery bypass grafting (CABG), and restenosis, and the secondary endpoint measures included recurrent angina, treadmill exercise (total exercise time, ST-segment decline, angina, and maximum exercise tolerance). The results showed that exercise was not clearly associated with reductions in cardiac death, recurrence of MI, repeated PCI, CABG, or restenosis. However, the exercise group exhibited greater improvements in recurrent angina, total exercise time, ST-segment decline, angina, and maximum exercise tolerance than did the control group. Future studies need to expand the sample size and improve the quality of reporting of RCTs. PMID:28303967

  9. Mechanical load plays little role in contraction-mediated glucose transport in mouse skeletal muscle

    PubMed Central

    Sandström, Marie E; Zhang, Shi-Jin; Westerblad, Håkan; Katz, Abram

    2007-01-01

    The factors responsible for control of glucose transport during exercise are not fully understood. We investigated the role of mechanical load in contraction-mediated glucose transport in an isolated muscle preparation. Mouse extensor digitorum longus muscles were stimulated with repeated contractions for 10 min with or without N-benzyl-p-toluene sulphonamide (BTS, an inhibitor of myosin II ATPase) to block crossbridge activity. BTS inhibited force production during repeated contraction to ∼5% of control. In contrast, BTS had little effect on glucose transport in the basal state (control = 0.55 ± 0.04; BTS = 0.47 ± 0.09 μmol (20 min)−1 ml−1) or after contraction (control = 2.27 ± 0.15; BTS = 2.10 ± 0.16 μmol (20 min)−1 ml−1). BTS did not significantly alter the contraction-mediated changes in high-energy phosphates, glutathione status (a measure of oxidant status) or AMP-activated protein kinase activity. In conclusion, these data show that mechanical load plays little role in contraction-mediated glucose transport. Instead, it is likely that the increased glucose transport during contraction is a consequence of the increase in myoplasmic Ca2+ and the subsequent alterations in metabolism, e.g. increased energy turnover and production of reactive oxygen species. PMID:17185338

  10. Effects of repeated anodal tDCS coupled with cognitive training for patients with severe traumatic brain injury: a pilot randomized controlled trial.

    PubMed

    Leśniak, Marcin; Polanowska, Katarzyna; Seniów, Joanna; Członkowska, Anna

    2014-01-01

    To determine whether cumulative anodal transcranial direct current stimulation (A-tDCS) of the left dorsolateral prefrontal cortex (DLPFC) could enhance rehabilitation of memory and attention in patients with traumatic brain injury (TBI). Inpatient and outpatient neurorehabilitation unit. Twenty-three adult patients, 4- to 92- months post severe TBI. Participants were randomly allocated to 2 groups. The experimental group received A-tDCS (10 minutes; 1 mA; in the DLPFC), followed by rehabilitative cognitive training, daily for 15 days. Controls received A-tDCS for 25 seconds (sham condition) with the same rehabilitation. Battery of memory and attention tests, which included visual and auditory modalities. Participants were tested twice before beginning rehabilitation (to control for spontaneous recovery), after rehabilitation completion, and 4 months later. Tests scores in both groups were similar at 3 weeks before and immediately before treatment. After treatment, the experimental group exhibited larger effect sizes in 6 of 8 cognitive outcome measures, but they were not significantly different from controls. At follow-up, differences remained insignificant. In contrast to previous studies, our study did not provide sufficient evidence to support the efficacy of repeated A-tDCS for enhancing rehabilitation of memory and attention in patients after severe TBI.

  11. Changes of pituitary gland volume in Kennedy disease.

    PubMed

    Pieper, C C; Teismann, I K; Konrad, C; Heindel, W L; Schiffbauer, H

    2013-12-01

    Kennedy disease is a rare X-linked neurodegenerative disorder caused by a CAG repeat expansion in the first exon of the androgen-receptor gene. Apart from neurologic signs, this mutation can cause a partial androgen insensitivity syndrome with typical alterations of gonadotropic hormones produced by the pituitary gland. The aim of the present study was therefore to evaluate the impact of Kennedy disease on pituitary gland volume under the hypothesis that endocrinologic changes caused by partial androgen insensitivity may lead to morphologic changes (ie, hypertrophy) of the pituitary gland. Pituitary gland volume was measured in sagittal sections of 3D T1-weighted 3T-MR imaging data of 8 patients with genetically proven Kennedy disease and compared with 16 healthy age-matched control subjects by use of Multitracer by a blinded, experienced radiologist. The results were analyzed by a univariant ANOVA with total brain volume as a covariant. Furthermore, correlation and linear regression analyses were performed for pituitary volume, patient age, disease duration, and CAG repeat expansion length. Intraobserver reliability was evaluated by means of the Pearson correlation coefficient. Pituitary volume was significantly larger in patients with Kennedy disease (636 [±90] mm(3)) than in healthy control subjects (534 [±91] mm(3)) (P = .041). There was no significant difference in total brain volume (P = .379). Control subjects showed a significant decrease in volume with age (r = -0.712, P = .002), whereas there was a trend to increasing gland volume in patients with Kennedy disease (r = 0.443, P = .272). Gland volume correlated with CAG repeat expansion length in patients (r = 0.630, P = .047). The correlation coefficient for intraobserver reliability was 0.94 (P < .001). Patients with Kennedy disease showed a significantly higher pituitary volume that correlated with the CAG repeat expansion length. This could reflect hypertrophy as the result of elevated gonadotropic hormone secretion caused by the androgen receptor mutation with partial androgen insensitivity.

  12. Validity of cardiac output measurement by the thermodilution method in the presence of acute tricuspid regurgitation.

    PubMed

    Boerboom, L E; Kinney, T E; Olinger, G N; Hoffmann, R G

    1993-10-01

    Evaluation of patients with acute tricuspid insufficiency may include assessment of cardiac output by the thermodilution method. The accuracy of estimates of thermodilution-derived cardiac output in the presence of tricuspid insufficiency has been questioned. This study was designed to determine the validity of the thermodilution technique in a canine model of acute reversible tricuspid insufficiency. Cardiac output as measured by thermodilution and electromagnetic flowmeter was compared at two grades of regurgitation. The relationship between these two methods (thermodilution/electromagnetic) changed significantly from a regression slope of 1.01 +/- 0.18 (mean +/- standard deviation) during control conditions to a slope of 0.86 +/- 0.23 (p < 0.02) during severe regurgitation. No significant change was observed between control and mild regurgitation or between the initial control value and a control measurement repeated after tricuspid insufficiency was reversed at the termination of the study. This study shows that in a canine model of severe acute tricuspid regurgitation the thermodilution method underestimates cardiac output by an amount that is proportional to the level of cardiac output and to the grade of regurgitation.

  13. Sensitivity and specificity of the empirical lymphocyte genome sensitivity (LGS) assay: implications for improving cancer diagnostics.

    PubMed

    Anderson, Diana; Najafzadeh, Mojgan; Gopalan, Rajendran; Ghaderi, Nader; Scally, Andrew J; Britland, Stephen T; Jacobs, Badie K; Reynolds, P Dominic; Davies, Justin; Wright, Andrew L; Al-Ghazal, Shariff; Sharpe, David; Denyer, Morgan C

    2014-10-01

    Lymphocyte responses from 208 individuals: 20 with melanoma, 34 with colon cancer, and 4 with lung cancer (58), 18 with suspected melanoma, 28 with polyposis, and 10 with COPD (56), and 94 healthy volunteers were examined. The natural logarithm of the Olive tail moment (OTM) was plotted for exposure to UVA through 5 different agar depths (100 cell measurements/depth) and analyzed using a repeated measures regression model. Responses of patients with cancer plateaued after treatment with different UVA intensities, but returned toward control values for healthy volunteers. For precancerous conditions and suspected cancers, intermediate responses occurred. ROC analysis of mean log OTMs, for cancers plus precancerous/suspect conditions vs. controls, cancer vs. precancerous/suspect conditions plus controls, and cancer vs. controls, gave areas under the curve of 0.87, 0.89, and 0.93, respectively (P<0.001). Optimization allowed test sensitivity or specificity to approach 100% with acceptable complementary measures. This modified comet assay could represent a stand-alone test or an adjunct to other investigative procedures for detecting cancer. © FASEB.

  14. Perpetual extraction of work from a nonequilibrium dynamical system under Markovian feedback control

    NASA Astrophysics Data System (ADS)

    Kosugi, Taichi

    2013-09-01

    By treating both control parameters and dynamical variables as probabilistic variables, we develop a succinct theory of perpetual extraction of work from a generic classical nonequilibrium system subject to a heat bath via repeated measurements under a Markovian feedback control. It is demonstrated that a problem for perpetual extraction of work in a nonequilibrium system is reduced to a problem of Markov chain in the higher-dimensional phase space. We derive a version of the detailed fluctuation theorem, which was originally derived for classical nonequilibrium systems by Horowitz and Vaikuntanathan [Phys. Rev. EPLEEE81539-375510.1103/PhysRevE.82.061120 82, 061120 (2010)], in a form suitable for the analyses of perpetual extraction of work. Since our theory is formulated for generic dynamics of probability distribution function in phase space, its application to a physical system is straightforward. As simple applications of the theory, two exactly solvable models are analyzed. The one is a nonequilibrium two-state system and the other is a particle confined to a one-dimensional harmonic potential in thermal equilibrium. For the former example, it is demonstrated that the observer on the transitory steps to the stationary state can lose energy and that work larger than that achieved in the stationary state can be extracted. For the latter example, it is demonstrated that the optimal protocol for the extraction of work via repeated measurements can differ from that via a single measurement. The validity of our version of the detailed fluctuation theorem, which determines the upper bound of the expected work in the stationary state, is also confirmed for both examples. These observations provide useful insights into exploration for realistic modeling of a machine that extracts work from its environment.

  15. High school students in a health career promotion program report fewer acts of aggression and violence.

    PubMed

    Oscós-Sánchez, Manuel Ángel; Lesser, Janna; Oscós-Flores, L Dolores

    2013-01-01

    This study examined the effects of two school-based programs on the perpetration of nonphysical aggression, physical violence, and intimate partner violence among high-risk secondary school students in an economically disadvantaged and predominantly Latino school district. The intervention program was El Joven Noble, and the control program was the Teen Medical Academy. The study used a repeated-measures quasi-experimental intervention/control design. The participants self-reported the previous 30 days' acts of nonphysical aggression, physical violence, and intimate partner violence at baseline and at 3 and 9 months after enrollment. Program- and grade-level effects at 3 and 9 months were examined using three-factor analyses of covariance models with one factor for repeated measures. The covariate in each of the models was the baseline measure of the dependent outcomes. No significant baseline differences were found between the participants in the intervention (n = 96) and control (n = 127) programs. At 9 months after enrollment in the study, high school students who participated in the Teen Medical Academy reported fewer acts of nonphysical aggression (p < .001) and physical violence (p = .002) than high school students who participated in El Joven Noble. Students who participated in the Teen Medical Academy also reported fewer acts of intimate partner violence (p = .02) than students who participated in El Joven Noble. High school students who participated in a health career promotion program reported fewer acts of aggression and violence as compared with high school students who participated in a culturally tailored character development program. Copyright © 2013 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  16. The use of bio-monitoring to assess exposure in the electroplating industry

    PubMed Central

    Beattie, Helen; Keen, Chris; Coldwell, Matthew; Tan, Emma; Morton, Jackie; McAlinden, John; Smith, Paul

    2017-01-01

    Workers in the electroplating industry are potentially exposed to a range of hazardous substances including nickel and hexavalent chromium (chromium VI) compounds. These can cause serious health effects, including cancer, asthma and dermatitis. This research aimed to investigate whether repeat biological monitoring (BM) over time could drive sustainable improvements in exposure control in the industry. BM was performed on multiple occasions over 3 years, at 53 electroplating companies in Great Britain. Surface and dermal contamination was also measured, and controls were assessed. Air monitoring was undertaken on repeat visits where previous BM results were of concern. There were significant reductions in urinary nickel and chromium levels over the lifetime of this work in the subset of companies where initially, control deficiencies were more significant. Increased risk awareness following provision of direct feedback to individual workers and targeted advice to companies is likely to have contributed to these reductions. This study has shown that exposures to chromium VI and nickel in the electroplating industry occur via a combination of inhalation, dermal and ingestion routes. Surface contamination found in areas such as canteens highlights the potential for transferral from work areas, and the importance of a regular cleaning regime. PMID:26627055

  17. The use of bio-monitoring to assess exposure in the electroplating industry.

    PubMed

    Beattie, Helen; Keen, Chris; Coldwell, Matthew; Tan, Emma; Morton, Jackie; McAlinden, John; Smith, Paul

    2017-01-01

    Workers in the electroplating industry are potentially exposed to a range of hazardous substances including nickel and hexavalent chromium (chromium VI) compounds. These can cause serious health effects, including cancer, asthma and dermatitis. This research aimed to investigate whether repeat biological monitoring (BM) over time could drive sustainable improvements in exposure control in the industry. BM was performed on multiple occasions over 3 years, at 53 electroplating companies in Great Britain. Surface and dermal contamination was also measured, and controls were assessed. Air monitoring was undertaken on repeat visits where previous BM results were of concern. There were significant reductions in urinary nickel and chromium levels over the lifetime of this work in the subset of companies where initially, control deficiencies were more significant. Increased risk awareness following provision of direct feedback to individual workers and targeted advice to companies is likely to have contributed to these reductions. This study has shown that exposures to chromium VI and nickel in the electroplating industry occur via a combination of inhalation, dermal and ingestion routes. Surface contamination found in areas such as canteens highlights the potential for transferral from work areas, and the importance of a regular cleaning regime.

  18. Neurogenesis and Helplessness are Mediated by Controllability in Males but not in Females

    PubMed Central

    Shors, Tracey J.; Mathew, Jason; Sisti, Helene M.; Edgecomb, Carol; Beckoff, Steven; Dalla, Christina

    2009-01-01

    Background Numerous studies have implicated neurogenesis in the hippocampus in animal models of depression, especially those related to controllability and learned helplessness. Here, we tested the hypothesis that uncontrollable, but not controllable stress would reduce cell proliferation in the hippocampus of male and female rats, and would relate to the expression of helplessness behavior. Methods To manipulate controllability, groups of male and female rats were trained in one session (acute stress) or over seven sessions (repeated stress) to escape a footshock, while yoked controls could not escape, but were exposed to the same amount of stress. Cell proliferation was assessed with immunohistochemistry of BrdU and immunofluorescence of BrdU and NeuN. Separate groups were exposed to either controllable or uncontrollable stress and their ability to learn to escape during training on a more difficult task was used as a behavioral measure of helplessness. Results Acute stress reduced cell proliferation in males, but did not affect proliferation in the female hippocampus. When animals were given the opportunity to learn to control the stress over days, males produced more cells than the yoked males without control. Repeated training with controllable stress did not influence proliferation in females. Under all conditions, males were more likely than females to express helplessness behavior, even males that were not previously stressed. Conclusions The modulation of neurogenesis by controllability was evident in males but not in females, as was the expression of helplessness behavior, despite the fact that men are less likely than women to experience depression. PMID:17306770

  19. Neurogenesis and helplessness are mediated by controllability in males but not in females.

    PubMed

    Shors, Tracey J; Mathew, Jason; Sisti, Helene M; Edgecomb, Carol; Beckoff, Steven; Dalla, Christina

    2007-09-01

    Numerous studies have implicated neurogenesis in the hippocampus in animal models of depression, especially those related to controllability and learned helplessness. Here, we tested the hypothesis that uncontrollable but not controllable stress would reduce cell proliferation in the hippocampus of male and female rats and would relate to the expression of helplessness behavior. To manipulate controllability, groups of male and female rats were trained in one session (acute stress) or over seven sessions (repeated stress) to escape a footshock, whereas yoked control subjects could not escape but were exposed to the same amount of stress. Cell proliferation was assessed with immunohistochemistry of bromodeoxyuridine (BrdU) and immunofluorescence of BrdU and neuronal nuclei (NeuN). Separate groups were exposed to either controllable or uncontrollable stress, and their ability to learn to escape during training on a more difficult task was used as a behavioral measure of helplessness. Acute stress reduced cell proliferation in males but did not affect proliferation in the female hippocampus. When animals were given the opportunity to learn to control the stress over seven days, males produced more cells than the yoked males without control. Repeated training with controllable stress did not influence proliferation in females. Under all conditions, males were more likely than females to express helplessness behavior, even males that were not previously stressed. The modulation of neurogenesis by controllability was evident in males but not in females, as was the expression of helplessness behavior, despite the fact that men are less likely than women to experience depression.

  20. Evidence for Acute Electrophysiological and Cognitive Changes Following Routine Soccer Heading.

    PubMed

    Di Virgilio, Thomas G; Hunter, Angus; Wilson, Lindsay; Stewart, William; Goodall, Stuart; Howatson, Glyn; Donaldson, David I; Ietswaart, Magdalena

    2016-11-01

    There is growing concern around the effects of concussion and sub-concussive impacts in sport. Routine game-play in soccer involves intentional and repeated head impacts through ball heading. Although heading is frequently cited as a risk to brain health, little data exist regarding the consequences of this activity. This study aims to assess the immediate outcomes of routine football heading using direct and sensitive measures of brain function. Nineteen amateur football players (5 females; age 22±3y) headed machine-projected soccer balls at standardized speeds, modelling routine soccer practice. The primary outcome measure of corticomotor inhibition measured using transcranial magnetic stimulation, was assessed prior to heading and repeated immediately, 24h, 48h and 2weeks post-heading. Secondary outcome measures were cortical excitability, postural control, and cognitive function. Immediately following heading an increase in corticomotor inhibition was detected; further to these electrophysiological alterations, measurable reduction memory function were also found. These acute changes appear transient, with values normalizing 24h post-heading. Sub-concussive head impacts routine in soccer heading are associated with immediate, measurable electrophysiological and cognitive impairments. Although these changes in brain function were transient, these effects may signal direct consequences of routine soccer heading on (long-term) brain health which requires further study. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. A Web-Based Weight Loss Programme Including Breakfast Cereals Results in Greater Loss of Body Mass than a Standardised Web-Based Programme in a Randomised Controlled Trial

    PubMed Central

    Margaret Ashwell, Margaret; Howarth, Elaine; Chesters, David; Allan, Peter; Hoyland, Alexa; Walton, Jenny

    2014-01-01

    Objective To test the hypothesis that promoting breakfast cereal consumption, as part of a web-based programme, results in loss of body mass. Methods Single centre, single blind, randomised parallel study. Test group followed a fully interactive website (B) with ‘prescribed’ breakfast cereals. Control group followed website (A) giving standard advice on weight loss. Study site visits at 0, 4, 12 and 24 weeks for measurements of height, weight, skinfolds, body fat, waist and hip circumference. 180 subjects were randomly allocated to two equal groups. Subjects were in good health and aged 19-50 years, with a BMI ranging from 25-40 kg/m2. At baseline there was no difference in mean age or BMI between the two groups. Results The percentage change in body mass loss was greater when following website B than website A (n = 90; ITT repeated measures p = 0.013). For completers (website A: n = 62, website B: n = 64), the percentage change in body mass loss was also greater for website B than website A (repeated measures p = 0.023). Conclusion The advice and motivation offered by an interactive website, including provision and consumption of breakfast cereals, results in significantly greater loss of body mass compared to the use of a standard website. It is not possible to discern which of the three factors is responsible. PMID:25428346

  2. [Effects of radiation emitted from mobile phones on short- term heart rate variability parameters].

    PubMed

    Yıldız, Metin; Yılmaz, Derya; Güler, Inan; Akgüllü, Cağdaş

    2012-08-01

    In this study, the effects of radiation emitted from mobile phone (MP) on heart rate variability (HRV) which is accepted a non-invasive indicator of autonomic nervous system (ANS) were investigated with considering the deficiency of previous studies. A randomized controlled study has been designed and utilized with 30 young and healthy volunteers. During the experiment that had three periods, the electrocardiogram (ECG) and respiration signals were recorded and MP was attached to subjects' right ear with a bone. Ten subjects selected randomly were exposed to high -level radiation during the second period (Experimental Group 1). Ten of others were exposed during the third period with maximum level radiation (Experimental Group 2). Ten records were also made while MP was closed as a control. Short -term HRV parameters were obtained and repeated measures ANOVA and suitable post-hoc tests applied to the results. According to the results of the repeated measures ANOVA; there were no significant main effects of groups. However, there were some significant differences in measuring time periods and groups*period interactions. The post-hoc tests showed that mean R to R interval and HF power are significantly changed by maximum radiation emitted from MP. Due to the radiation emitted from MPs at maximum power, some changes may occur in HRV parameters that are associated with increased parasympathetic activity. But, the level of these changes is similar to daily activities as excitement, and stand up.

  3. Repeatability study of replicate crash tests: A signal analysis approach.

    PubMed

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2017-10-03

    To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.

  4. A proteomics performance standard to support measurement quality in proteomics.

    PubMed

    Beasley-Green, Ashley; Bunk, David; Rudnick, Paul; Kilpatrick, Lisa; Phinney, Karen

    2012-04-01

    The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography.

    PubMed

    Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won

    2017-01-01

    To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.

  6. A novel magnet based 3D printed marker wand as basis for repeated in-shoe multi segment foot analysis: a proof of concept.

    PubMed

    Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin

    2017-01-01

    Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.

  7. Performance evaluation of a six-axis generalized force-reflecting teleoperator

    NASA Technical Reports Server (NTRS)

    Hannaford, B.; Wood, L.; Guggisberg, B.; Mcaffee, D.; Zak, H.

    1989-01-01

    Work in real-time distributed computation and control has culminated in a prototype force-reflecting telemanipulation system having a dissimilar master (cable-driven, force-reflecting hand controller) and a slave (PUMA 560 robot with custom controller), an extremely high sampling rate (1000 Hz), and a low loop computation delay (5 msec). In a series of experiments with this system and five trained test operators covering over 100 hours of teleoperation, performance was measured in a series of generic and application-driven tasks with and without force feedback, and with control shared between teleoperation and local sensor referenced control. Measurements defining task performance included 100-Hz recording of six-axis force/torque information from the slave manipulator wrist, task completion time, and visual observation of predefined task errors. The task consisted of high precision peg-in-hole insertion, electrical connectors, velcro attach-de-attach, and a twist-lock multi-pin connector. Each task was repeated three times under several operating conditions: normal bilateral telemanipulation, forward position control without force feedback, and shared control. In shared control, orientation was locally servo controlled to comply with applied torques, while translation was under operator control. All performance measures improved as capability was added along a spectrum of capabilities ranging from pure position control through force-reflecting teleoperation and shared control. Performance was optimal for the bare-handed operator.

  8. Use of Repeated Blood Pressure and Cholesterol Measurements to Improve Cardiovascular Disease Risk Prediction: An Individual-Participant-Data Meta-Analysis

    PubMed Central

    Barrett, Jessica; Pennells, Lisa; Sweeting, Michael; Willeit, Peter; Di Angelantonio, Emanuele; Gudnason, Vilmundur; Nordestgaard, Børge G.; Psaty, Bruce M; Goldbourt, Uri; Best, Lyle G; Assmann, Gerd; Salonen, Jukka T; Nietert, Paul J; Verschuren, W. M. Monique; Brunner, Eric J; Kronmal, Richard A; Salomaa, Veikko; Bakker, Stephan J L; Dagenais, Gilles R; Sato, Shinichi; Jansson, Jan-Håkan; Willeit, Johann; Onat, Altan; de la Cámara, Agustin Gómez; Roussel, Ronan; Völzke, Henry; Dankner, Rachel; Tipping, Robert W; Meade, Tom W; Donfrancesco, Chiara; Kuller, Lewis H; Peters, Annette; Gallacher, John; Kromhout, Daan; Iso, Hiroyasu; Knuiman, Matthew; Casiglia, Edoardo; Kavousi, Maryam; Palmieri, Luigi; Sundström, Johan; Davis, Barry R; Njølstad, Inger; Couper, David; Danesh, John; Thompson, Simon G; Wood, Angela

    2017-01-01

    Abstract The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data encompassing 1962–2014) with more than 1 million measurements of systolic blood pressure, total cholesterol, and high-density lipoprotein cholesterol. Over a median 12 years of follow-up, 21,170 CVD events occurred. Risk prediction models using cumulative mean values of repeated measurements and summary measures from longitudinal modeling of the repeated measurements were compared with models using measurements from a single time point. Risk discrimination (C-index) and net reclassification were calculated, and changes in C-indices were meta-analyzed across studies. Compared with the single-time-point model, the cumulative means and longitudinal models increased the C-index by 0.0040 (95% confidence interval (CI): 0.0023, 0.0057) and 0.0023 (95% CI: 0.0005, 0.0042), respectively. Reclassification was also improved in both models; compared with the single-time-point model, overall net reclassification improvements were 0.0369 (95% CI: 0.0303, 0.0436) for the cumulative-means model and 0.0177 (95% CI: 0.0110, 0.0243) for the longitudinal model. In conclusion, incorporating repeated measurements of blood pressure and cholesterol into CVD risk prediction models slightly improves risk prediction. PMID:28549073

  9. Population Fisher information matrix and optimal design of discrete data responses in population pharmacodynamic experiments.

    PubMed

    Ogungbenro, Kayode; Aarons, Leon

    2011-08-01

    In the recent years, interest in the application of experimental design theory to population pharmacokinetic (PK) and pharmacodynamic (PD) experiments has increased. The aim is to improve the efficiency and the precision with which parameters are estimated during data analysis and sometimes to increase the power and reduce the sample size required for hypothesis testing. The population Fisher information matrix (PFIM) has been described for uniresponse and multiresponse population PK experiments for design evaluation and optimisation. Despite these developments and availability of tools for optimal design of population PK and PD experiments much of the effort has been focused on repeated continuous variable measurements with less work being done on repeated discrete type measurements. Discrete data arise mainly in PDs e.g. ordinal, nominal, dichotomous or count measurements. This paper implements expressions for the PFIM for repeated ordinal, dichotomous and count measurements based on analysis by a mixed-effects modelling technique. Three simulation studies were used to investigate the performance of the expressions. Example 1 is based on repeated dichotomous measurements, Example 2 is based on repeated count measurements and Example 3 is based on repeated ordinal measurements. Data simulated in MATLAB were analysed using NONMEM (Laplace method) and the glmmML package in R (Laplace and adaptive Gauss-Hermite quadrature methods). The results obtained for Examples 1 and 2 showed good agreement between the relative standard errors obtained using the PFIM and simulations. The results obtained for Example 3 showed the importance of sampling at the most informative time points. Implementation of these expressions will provide the opportunity for efficient design of population PD experiments that involve discrete type data through design evaluation and optimisation.

  10. Evaluation of individual cognitive remediation therapy (CRT) for the treatment of young people with anorexia nervosa.

    PubMed

    Giombini, Lucia; Moynihan, Jennifer; Turco, Matteo; Nesbitt, Sophie

    2017-12-01

    Research suggests that there are cognitive inefficiencies underlying Anorexia Nervosa (AN), with CRT showing promise in improving these inefficiencies in adults. This area has yet to be explored in a younger population. The aim of this study was to evaluate the use of CRT for young people. A within-subjects design was used to compare the performance of children and adolescents with AN on several neuropsychological measures administered before and after a course of CRT. Ninety-two female participants diagnosed with AN aged between 11 and 17 (M = 14.8, SD = 1.6), all receiving treatment at a specialist inpatient unit. The assessment consisted of the Rey-Osterrieth Complex Figure test (ROCFT), the Behaviour Rating Inventory of Executive Function-Self-Report (BRIEF-SR), and the D-KEFS Colour-Word Interference Test (CWT). Repeated-measures t tests were used to analyse the ROCFT and BRIEF-SR data. There was a significant improvement in Central Coherence Index (p < .001), Immediate Recall (p < .001), Shift (p < .001) Cognitive Shift (p = 002), Behavioural shift (p < .001), Emotional Control (p < .001), Working Memory (p = .001), Plan/Organize (p < .001), Monitor (p = .001) BRI (p < .001), MI (p = .001), and GEC (p < .001). On the D-KEFS CWT, a repeated-measure Wilcoxon signed-rank test revealed a significant improvement in Error Rate (p = .019) and a repeated-measures t test revealed a significant improvement in time taken (p < .001). Results suggest that CRT for children and adolescents with AN could strengthen specific cognitive domains.

  11. Return of postural control to baseline after anaerobic and aerobic exercise protocols.

    PubMed

    Fox, Zachary G; Mihalik, Jason P; Blackburn, J Troy; Battaglini, Claudio L; Guskiewicz, Kevin M

    2008-01-01

    With regard to sideline concussion testing, the effect of fatigue associated with different types of exercise on postural control is unknown. To evaluate the effects of fatigue on postural control in healthy college-aged athletes performing anaerobic and aerobic exercise protocols and to establish an immediate recovery time course from each exercise protocol for postural control measures to return to baseline status. Counterbalanced, repeated measures. Research laboratory. Thirty-six collegiate athletes (18 males, 18 females; age = 19.00 +/- 1.01 years, height = 172.44 +/- 10.47 cm, mass = 69.72 +/- 12.84 kg). Participants completed 2 counterbalanced sessions within 7 days. Each session consisted of 1 exercise protocol followed by postexercise measures of postural control taken at 3-, 8-, 13-, and 18-minute time intervals. Baseline measures were established during the first session, before the specified exertion protocol was performed. Balance Error Scoring System (BESS) results, sway velocity, and elliptical sway area. We found a decrease in postural control after each exercise protocol for all dependent measures. An interaction was noted between exercise protocol and time for total BESS score (P = .002). For both exercise protocols, all measures of postural control returned to baseline within 13 minutes. Postural control was negatively affected after anaerobic and aerobic exercise protocols as measured by total BESS score, elliptical sway area, and sway velocity. The effect of exertion lasted up to 13 minutes after each exercise was completed. Certified athletic trainers and clinicians should be aware of these effects and their recovery time course when determining an appropriate time to administer sideline assessments of postural control after a suspected mild traumatic brain injury.

  12. Goal equivalent manifold analysis of task performance in non-specific LBP and healthy subjects during repetitive trunk movement: Effect of load, velocity, symmetry.

    PubMed

    Chehrehrazi, Mahshid; Sanjari, Mohammad Ali; Mokhtarinia, Hamid Reza; Jamshidi, Ali Ashraf; Maroufi, Nader; Parnianpour, Mohamad

    2017-01-01

    Motor abundance allows reliability of motor performance despite its variability. The nature of this variability provides important information on the flexibility of control strategies. This feature of control may be affected by low back pain (LPB) and trunk flexion/extension conditions. Goal equivalent manifold (GEM) analysis was used to quantify the ability to exploit motor abundance during repeated trunk flexion/extension in healthy individuals and people with chronic non-specific LBP (CNSLBP). Kinematic data were collected from 22 healthy volunteers and 22 CNSLBP patients during metronomically timed, repeated trunk flexion/extension in three conditions of symmetry, velocity, and loading; each at two levels. A goal function for the task was defined as maintaining a constant movement time at each cycle. Given the GEM, flexibility index and performance index were calculated respectively as amounts of goal-equivalent variability and the ratio of goal-equivalent to non-goal-equivalent variability. CNSLBP group was as similar as healthy individuals in both flexibility index (p=0.41) and performance index (p=0.24). Performance index was higher in asymmetric (p<0.001), high velocity (p<0.001), and loaded (p=0.006) conditions. Performance and flexibility in using motor abundance were influenced by repeated trunk flexion/extension conditions. However, these measures were not significantly affected by CNSLBP. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Can Social Network Analysis Help Address the High Rates of Bacterial Sexually Transmitted Infections in Saskatchewan?

    PubMed

    Trecker, Molly A; Dillon, Jo-Anne R; Lloyd, Kathy; Hennink, Maurice; Jolly, Ann; Waldner, Cheryl

    2017-06-01

    Saskatchewan has one of the highest rates of gonorrhea among the Canadian provinces-more than double the national rate. In light of these high rates, and the growing threat of untreatable infections, improved understanding of gonorrhea transmission dynamics in the province and evaluation of the current system and tools for disease control are important. We extracted data from a cross-sectional sample of laboratory-confirmed gonorrhea cases between 2003 and 2012 from the notifiable disease files of the Regina Qu'Appelle Health Region. The database was stratified by calendar year, and social network analysis combined with statistical modeling was used to identify associations between measures of connection within the network and the odds of repeat gonorrhea and risk of coinfection with chlamydia at the time of diagnosis. Networks were highly fragmented. Younger age and component size were positively associated with being coinfected with chlamydia. Being coinfected, reporting sex trade involvement, and component size were all positively associated with repeat infection. This is the first study to apply social network analysis to gonorrhea transmission in Saskatchewan and contributes important information about the relationship of network connections to gonorrhea/chlamydia coinfection and repeat gonorrhea. This study also suggests several areas for change of systems-related factors that could greatly increase understanding of social networks and enhance the potential for bacterial sexually transmitted infection control in Saskatchewan.

  14. Strategy When Faced with Failure: Persistence and Degree Attainment of Course Repeaters versus Non-Repeaters. AIR 2002 Forum Paper.

    ERIC Educational Resources Information Center

    Fenton, Kathleen S.

    Graduation and persistence rates were compared for 184 students, 92 of whom had repeated multiple courses or at least 1 course 3 times. A control group of 92 nonrepeating students was drawn from the remaining 303 students of the entire 1996 cohort. There was no difference between the graduation rate of repeaters and nonrepeaters. The persistence…

  15. Influence of radiographic techniques on the measurement of femoral anteversion angles and a conformation score of pelvic limbs in Labrador retrievers.

    PubMed

    Mostafa, Ayman A; Cunningham, Devin P; Boudrieau, Randy J; Kowaleski, Michael P; Griffon, Dominique J

    2018-04-01

    To determine repeatability of and correlation between 2 radiographic measurements of femoral anteversion angles (FAA) and to determine their influence on a score derived from tibial plateau angle (TPA) and FAA to predict the risk of cranial cruciate ligament disease (CCLD). Prospective clinical study. Forty-eight Labrador retrievers with or without CCLD. FAA and CCLD scores were calculated for each limb from extended pelvic radiographs (t-FAA) or angled (a-FAA) projections of the femur by 3 investigators. One investigator repeated measurements twice. Data were analyzed for repeatability, correlation between t-FAA and a-FAA, and their influence on CCLD scores. FAA correlated most strongly with the distance between the femoral head and the femoral axis on mediolateral radiographs, a measurement with excellent repeatability. t-FAA and a-FAA correlated with each other (r > 0.79, P < .0001), although t-FAA were about 1° greater than a-FAA (P = .01). Intrainvestigator and interinvestigator repeatability of the CCLD score was fair when derived from t-FAA and good to excellent when derived from a-FAA. CCLD scores differed between radiographic techniques but led to different predictions in only 9 (10%) limbs, all with lower TPA and CCLD scores than the rest of the population. a-FAA correlated strongly with t-FAA and improved the repeatability of CCLD scores within and between investigators. A craniocaudal angled beam projection of the femur is a suitable alternative to a ventrodorsal pelvic radiograph when measuring FAA and may improve the repeatability and positive predictive value of CCLD scores. © 2018 The American College of Veterinary Surgeons.

  16. Repeat surfactant therapy for postsurfactant slump.

    PubMed

    Katz, L A; Klein, J M

    2006-07-01

    To evaluate repeat surfactant therapy for the treatment of respiratory failure associated with postsurfactant slump in extremely low birth weight infants (ELBW) by characterizing the population of premature infants who develop postsurfactant slump and measuring their response to a secondary course of surfactant therapy. A retrospective analysis of a cohort of all patients admitted over a 3-year period with birth weights <1000 g (ELBW infants). Information was collected by chart review and the patients were categorized into three distinct groups for analysis. Initial surfactant only, patients who received surfactant replacement therapy only for respiratory distress syndrome (RDS); repeat surfactant, patients who received both initial surfactant replacement for RDS and repeat surfactant therapy for postsurfactant slump (defined as respiratory failure after 6 days of age), and no surfactant, patients in whom no surfactant was ever administered. A respiratory severity score (RSS) was used to measure the severity of lung disease and response to surfactant therapy. Over 3 years, there were 165 ELBW infants who could develop postsurfactant slump and be eligible for repeat surfactant therapy. There were 39 infants who never received any surfactant therapy estimated gestational age (EGA) 27.7 +/- 1.7, birth weight 856 +/- 109 g) either at birth or after 6 days of life. There were 126 patients treated for RDS with initial surfactant replacement therapy (EGA 25.6 +/- 1.9 weeks, birth weight 713 +/- 179 g). Out of these RDS patients, 101 improved with an initial course of surfactant therapy (EGA 26 +/- 1.8, birth weight 751 +/- 143 g), but 25 (20% of the patients with RDS) developed postsurfactant slump and received a repeat course of surfactant therapy (EGA 24.7 +/- 1.2, birth weight 647 +/- 120 g). The repeat surfactant group (postsurfactant slump) was significantly more premature and had significantly lower birth weights compared to both the initial surfactant only group and the no surfactant ever group. Logistic regression analysis revealed that lack of antenatal steroids, earlier gestational age, and the receiving of 2 or more doses of surfactant to treat the initial RDS were significantly associated with receiving repeat surfactant therapy for postsurfactant slump. Of the 25 patients treated with a repeat course of surfactant therapy more than 70% of patients (n = 18) had an improvement in their lung disease with a 15% reduction in their RSS. This improvement was significant at all time points evaluated (12, 24, and 48 h). We found that a repeat course of surfactant therapy, after day of life 6, led to a significant improvement in hypoxemic respiratory failure in premature infants with postsurfactant slump. Infants who received repeat surfactant therapy were born at a significantly earlier gestational age, had significantly smaller birth weight and had significantly worse lung disease. They were significantly less likely to have received antenatal steroids and were significantly more likely to have received multiple doses of surfactant to treat their initial RDS. A repeat course of surfactant therapy for patients with postsurfactant slump appeared beneficial in the short-term. These initial findings would support performing randomized control trials of repeat surfactant therapy for postsurfactant slump.

  17. Repeatability of standard metabolic rate (SMR) in a small fish, the spined loach (Cobitis taenia).

    PubMed

    Maciak, Sebastian; Konarzewski, Marek

    2010-10-01

    Significant repeatability of a trait of interest is an essential assumption for undertaking studies of phenotypic variability. It is especially important in studies on highly variable traits, such as metabolic rates. Recent publications suggest that resting/basal metabolic rate of homeotherms is repeatable across wide range of species. In contrast, studies on the consistency of standard metabolic rate (SMR) in ectotherms, particularly fish, are scarce. Here we present a comprehensive analysis of several important technical aspects of body mass-corrected SMR measurements and its repeatability in a small (average weight approximately 3g) fish, the spined loach (Cobitis taenia). First we demonstrated that release of oxygen from the walls of metabolic chambers exposed to hypoxic conditions did not confound SMR measurements. Next, using principle of propagation of measurement uncertainties we demonstrated that in aquatic systems, measurement error is significantly higher in open than closed respirometry setups. The measurement error for SMR of a small fish determined in a closed aquatic system is comparable to that obtainable using top-notch open-flow systems used for air-breathing terrestrial animals. Using a closed respirometer we demonstrated that body mass-corrected SMR in spined loaches was repeatable under both normoxia and hypoxia over a 5-month period (Pearson correlation r=0.68 and r=0.73, respectively) as well as across both conditions (intraclass correlation coefficient tau=0.30). In these analyses we accounted for possible effect of oxygen consumption of the oxygen electrode on repeatability of SMR. Significant SMR consistency was accompanied by significant repeatability of body mass (intraclass correlation coefficient tau=0.86). To our knowledge, this is the first study showing long-term repeatability of body mass and SMR in a small fish, and is consistent with the existence of heritable variation of these two traits. 2010 Elsevier Inc. All rights reserved.

  18. Comparison of the effects of vapocoolant spray and topical anesthetic cream on pain during needle electromyography in the medial gastrocnemius.

    PubMed

    Moon, Young-Eun; Kim, Sang-Hyun; Choi, Won-Hyeok

    2013-05-01

    To compare the effects of a vapocoolant spray and an eutectic mixture of local anesthetics (EMLA) cream in reducing pain during needle electromyography examination. Randomized controlled trial. Physical medicine and rehabilitation department of a university hospital. Adults who underwent needle electromyography (N=99) were randomized to 1 of 2 experimental groups or the control group. Two patients dropped out during the study. In the experimental groups, vapocoolant spray or EMLA cream were applied before needle electromyography. In the control group, needle electromyography was performed without pretreatment. Intensity of pain associated with needle electromyography was assessed using a 100-mm visual analog scale (VAS). Patient satisfaction and preference for repeated use were measured using a 5-point Likert scale. VAS score for pain intensity was significantly lower in the spray group (31.9; 95% confidence interval [CI], 22.0-41.7) compared with the control group (52.9; 95% CI, 45.9-60.0; P=.002), whereas there was no significant difference between the EMLA cream group (42.4; 95% CI, 34.2-50.7) and the control group. Patient satisfaction and preference for repeated use were higher in the spray group than the EMLA group. Vapocoolant spray was more effective than EMLA cream in reducing pain during needle electromyography. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Demethylation regulation of BDNF gene expression in dorsal root ganglion neurons is implicated in opioid-induced pain hypersensitivity in rats.

    PubMed

    Chao, Yu-Chieh; Xie, Fang; Li, Xueyang; Guo, Ruijuan; Yang, Ning; Zhang, Chen; Shi, Rong; Guan, Yun; Yue, Yun; Wang, Yun

    2016-07-01

    Repeated administration of morphine may result in opioid-induced hypersensitivity (OIH), which involves altered expression of numerous genes, including brain-derived neurotrophic factor (BDNF) in dorsal root ganglion (DRG) neurons. Yet, it remains unclear how BDNF expression is increased in DRG neurons after repeated morphine treatment. DNA methylation is an important mechanism of epigenetic control of gene expression. In the current study, we hypothesized that the demethylation regulation of certain BDNF gene promoters in DRG neurons may contribute to the development of OIH. Real-time RT-PCR was used to assess changes in the mRNA transcription levels of major BDNF exons including exon I, II, IV, VI, as well as total BDNF mRNA in DRGs from rats after repeated morphine administration. The levels of exon IV and total BDNF mRNA were significantly upregulated by repeated morphine administration, as compared to that in saline control group. Further, ELISA array and immunocytochemistry study revealed a robust upregulation of BDNF protein expression in DRG neurons after repeated morphine exposure. Correspondingly, the methylation levels of BDNF exon IV promoter showed a significant downregulation by morphine treatment. Importantly, intrathecal administration of a BDNF antibody, but not control IgG, significantly inhibited mechanical hypersensitivity that developed in rats after repeated morphine treatment. Conversely, intrathecal administration of an inhibitor of DNA methylation, 5-aza-2'-deoxycytidine (5-aza-dC) markedly upregulated the BDNF protein expression in DRG neurons and enhanced the mechanical allodynia after repeated morphine exposure. Together, our findings suggest that demethylation regulation of BDNF gene promoter may be implicated in the development of OIH through epigenetic control of BDNF expression in DRG neurons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Targeting Estrogen Receptor-Beta in Triple-Negative Breast Cancer

    DTIC Science & Technology

    2014-04-01

    polyacrylamide gels. Proteins were transferred to a nitrocellulose membrane for 1.5 hr at 0.35 A. Membranes were blocked with 5% nonfat milk and...PerkinElmer, Waltham, MA). Total protein was measured using the Bradford Method (Bio-Rad), and raw luciferase data were normalized to total protein ...are expressed as fold induction of raw luciferase units per mg protein over the DMSO control ± SD. Experiments were repeated at least twice. *p

  1. Organizational Wellness Program Implementation and Evaluation: A Holistic Approach to Improve the Wellbeing of Middle Managers.

    PubMed

    Medina, Maria Del Consuelo; Calderon, Angelica; Blunk, Dan I; Mills, Brandy W; Leiner, Marie

    2018-06-01

    : Employee wellness programs can provide benefits to institutions as well as employees and their families. Despite the attempts of some organizations to implement programs that take a holistic approach to improve physical, mental, and social wellness, the most common programs are exclusively comprised of physical and nutritional components. In this study, we implemented a wellness program intervention, including training using a holistic approach to improve the wellbeing of middle managers in several multinational organizations. We included control and experimental groups to measure wellness and teamwork with two repeated measures. Our results indicated that employees receiving the intervention had improved measures of wellness and teamwork. A positive relationship was found between wellness and teamwork in the experimental group when compared with the control group. Taken together, the data suggest that implementation of these programs would provide valuable outcomes for both employees and organizations.

  2. Perturbing engine performance measurements to determine optimal engine control settings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Li; Lee, Donghoon; Yilmaz, Hakan

    Methods and systems for optimizing a performance of a vehicle engine are provided. The method includes determining an initial value for a first engine control parameter based on one or more detected operating conditions of the vehicle engine, determining a value of an engine performance variable, and artificially perturbing the determined value of the engine performance variable. The initial value for the first engine control parameter is then adjusted based on the perturbed engine performance variable causing the engine performance variable to approach a target engine performance variable. Operation of the vehicle engine is controlled based on the adjusted initialmore » value for the first engine control parameter. These acts are repeated until the engine performance variable approaches the target engine performance variable.« less

  3. Association between Proton Magnetic Resonance Spectroscopy Measurements and CAG Repeat Number in Patients with Spinocerebellar Ataxias 2, 3, or 6

    PubMed Central

    Wang, Po-Shan; Chen, Hung-Chieh; Wu, Hsiu-Mei; Lirng, Jiing-Feng; Wu, Yu-Te; Soong, Bing-Wen

    2012-01-01

    The aim of this study was to correlate magnetic resonance spectroscopy (MRS) measurements, including that for the N-acetyl aspartate (NAA)/creatine (Cr) ratio in the vermis (denoted V-NAA), right cerebellar hemisphere (R-NAA), and left (L-NAA) cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA) score for patients with spinocerebellar ataxia (SCA) types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score) in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA. PMID:23094053

  4. Perceptions of control in adults with epilepsy.

    PubMed

    Gehlert, S

    1994-01-01

    That psychosocial problems are extant in epilepsy is evidenced by a suicide rate among epileptic persons five times that of the general population and an unemployment rate estimated to be more than twice that of the population as a whole. External perceptions of control secondary to repeated episodes of seizure activity that generalize to the social sphere have been implicated as causes of these problems. The hypothesis that individuals who continue to have seizures become more and more external in perceptions of control was tested by a survey mailed to a sample of individuals with epilepsy in a metropolitan area of the Midwest. Dependent variables were, scores on instruments measuring locus of control and attributional style. The independent variable was a measure of seizure control based on present age, age at onset, and length of time since last seizure. Gender, socioeconomic status, and certain parenting characteristics were included as control variables, as they are also known to affect perceptions of control. Analysis by multiple regression techniques supported the study's hypothesis when perceptions of control was conceptualized as learned helplessness for bad, but not for good, events. The hypothesis was not confirmed when perceptions of control was conceptualized as either general or health locus of control.

  5. Feasibility of spatial frequency domain imaging (SFDI) for optically characterizing a preclinical oncology model.

    PubMed

    Tabassum, Syeda; Zhao, Yanyu; Istfan, Raeef; Wu, Junjie; Waxman, David J; Roblyer, Darren

    2016-10-01

    Determination of chemotherapy efficacy early during treatment would provide more opportunities for physicians to alter and adapt treatment plans. Diffuse optical technologies may be ideally suited to track early biological events following chemotherapy administration due to low cost and high information content. We evaluated the use of spatial frequency domain imaging (SFDI) to characterize a small animal tumor model in order to move towards the goal of endogenous optical monitoring of cancer therapy in a controlled preclinical setting. The effects of key measurement parameters including the choice of imaging spatial frequency and the repeatability of measurements were evaluated. The precision of SFDI optical property extractions over repeat mouse measurements was determined to be within 3.52% for move and replace experiments. Baseline optical properties and chromophore values as well as intratumor heterogeneity were evaluated over 25 tumors. Additionally, tumor growth and chemotherapy response were monitored over a 45 day longitudinal study in a small number of mice to demonstrate the ability of SFDI to track treatment effects. Optical scattering and oxygen saturation increased as much as 70% and 25% respectively in treated tumors, suggesting SFDI may be useful for preclinical tracking of cancer therapies.

  6. Development and assessment of a fiber-optic liquid level sensor with long-period fiber grating and Shewhart control charts

    NASA Astrophysics Data System (ADS)

    Wang, Jian-Neng; Jan, Chen-Han; Tang, Jaw-Luen; Wu, Wei-Te; Chen, Der-Cheng; Chen, Chien-Hsing; Syu, Jial-Yan; Luo, Ching-Ying

    2011-12-01

    This paper presents the development and assessment of a liquid level sensor using long-period fiber grating (LPFG) technology and Shewhart control charts. The 22-mm LPFGs were fabricated with the point-by-point CO2 laser engraving method. This sensor was designed in such a way that it could be moved up and down with a position controller. The experimental section covered LPFG position sensing test, liquid level detection capacity and reliability measurements, and sensing resolution evaluation. LPFG position sensing test was studied and confirmed by the resonance wavelength shifts which were significantly generated when 75% of the LPFG was immersed in water. There were ten groups of different liquid level capacity testing and each group underwent ten repeated measurements. Based on Shewhart control charts including an X-bar chart, s chart, and R chart, the results showed all measurands within the upper and lower control limits. This sensor was reliable and the liquid level could be measured at least 1000 mm. The transmission loss versus the percent of immersion of the LPFG sensor for water and green tea was used to study the sensing resolution. The findings show the LPFG-based liquid sensor had at least 1000-mm level measurement capacity and about 2-mm resolution.

  7. Interlaboratory Analytical Comparison of Fatty Acid Concentrations in Serum or Plasma

    PubMed Central

    Schantz, Michele M.; Powers, Carissa D.; Schleicher, Rosemary L.; Betz, Joseph M.; Wise, Stephen A.

    2016-01-01

    The National Institute of Standards and Technology, in collaboration with the National Institutes of Health Office of Dietary Supplements and the Centers for Disease Control and Prevention, is conducting an accuracy-based program for improving the comparability of individual fatty acid measurements in serum and plasma. To date, two exercises of the Fatty Acid Quality Assurance Program (FAQAP) were conducted with 11 and 14 participants, respectively. The results from these two exercises indicate the need to improve the within-lab repeatability and between-lab reproducibility thus providing more confidence in the comparability of fatty acid measurements. PMID:27662814

  8. Creatine-electrolyte supplementation improves repeated sprint cycling performance: A double blind randomized control study.

    PubMed

    Crisafulli, Daniel L; Buddhadev, Harsh H; Brilla, Lorrie R; Chalmers, Gordon R; Suprak, David N; San Juan, Jun G

    2018-01-01

    Creatine supplementation is recommended as an ergogenic aid to improve repeated sprint cycling performance. Furthermore, creatine uptake is increased in the presence of electrolytes. Prior research examining the effect of a creatine-electrolyte (CE) supplement on repeated sprint cycling performance, however, did not show post-supplementation improvement. The purpose of this double blind randomized control study was to investigate the effect of a six-week CE supplementation intervention on overall and repeated peak and mean power output during repeated cycling sprints with recovery periods of 2 min between sprints. Peak and mean power generated by 23 male recreational cyclists (CE group: n  = 12; 24.0 ± 4.2 years; placebo (P) group: n  = 11; 23.3 ± 3.1 years) were measured on a Velotron ergometer as they completed five 15-s cycling sprints, with 2 min of recovery between sprints, pre- and post-supplementation. Mixed-model ANOVAs were used for statistical analyses. A supplement-time interaction showed a 4% increase in overall peak power (pre: 734 ± 75 W; post: 765 ± 71 W; p  = 0.040; η p 2  = 0.187) and a 5% increase in overall mean power (pre: 586 ± 72 W; post: 615 ± 74 W; p  = 0.019; η p 2  = 0.234) from pre- to post-supplementation for the CE group. For the P group, no differences were observed in overall peak (pre: 768 ± 95 W; post: 772 ± 108 W; p  = 0.735) and overall mean power (pre: 638 ± 77 W; post: 643 ± 92 W; p  = 0.435) from pre- to post-testing. For repeated sprint analysis, peak (pre: 737 ± 88 W; post: 767 ± 92 W; p  = 0.002; η p 2  = 0.380) and mean (pre: 650 ± 92 W; post: 694 ± 87 W; p  < 0.001; η p 2  = 0.578) power output were significantly increased only in the first sprint effort in CE group from pre- to post-supplementation testing. For the P group, no differences were observed for repeated sprint performance. A CE supplement improves overall and repeated short duration sprint cycling performance when sprints are interspersed with adequate recovery periods.

  9. A computerized photographic method to evaluate changes in head posture and scapular position following rapid palatal expansion: a pilot study.

    PubMed

    Cerruto, Carmen; Di Vece, Luca; Doldo, Tiziana; Giovannetti, Agostino; Polimeni, Antonella; Goracci, Cecilia

    2012-01-01

    To assess the applicability of a computerized method to measure on digital photographs the changes in head and scapular posture following rapid palatal expansion (RPE) treatment. Randomized controlled trial. Twenty-three children (age 9.2 +/- 70.88 years) diagnosed with maxillary constriction were randomly divided into two groups: 1. Study group (n = 12): patients receiving RPE treatment; 2. Untreated controls (n = 11). Postural measurements were taken on frontal, lateral, and dorsal views of each subject. In the study group measurements were taken at T0 (the day orthodontic records were taken), T1 (end of RPE active phase), and T2 (RPE removal). In controls the same observations were conducted at T0 and T1(98.18 +/- 36.01 days after T0). Measurements were statistically analyzed (Intraclass Correlation Coefficient, t-tests, Signed Rank test, One-Way Repeated Measures Analysis of Variance, Tukey test; p < 0.05). In the study group a significant reduction in forward head posture (FHP) occurred between T0 and T1. Forward shoulder posture (FSP) decreased significantly between T1 and T2. At T1 treated patients exhibited significantly lower values of the measurements indicating FHP and FSP than controls. Changes in head and scapular posture following RPE treatment can be documented with computerized measurements on digital photographs.

  10. Comparison of the Effects of Lanolin, Peppermint, and Dexpanthenol Creams on Treatment of Traumatic Nipples in Breastfeeding Mothers

    PubMed Central

    Shanazi, Mahnaz; Farshbaf Khalili, Azizeh; Kamalifard, Mahin; Asghari Jafarabadi, Mohammad; Masoudin, Kazhal; Esmaeli, Fariba

    2015-01-01

    Introduction: Traumatic nipple is among the most common problems of the breastfeeding period which leads to early cessation of breastfeeding. The study aimed to compare the effects of the lanolin, peppermint, and dexpanthenol creams on the treatment of traumatic nipples. Methods: This double-blind randomized controlled trial was carried out on 126 breastfeeding mothers. The mothers had visited at the health centers and children’s hospitals in Sanandaj City. The selected participants were randomly divided into the following three groups of lanolin, peppermint, and dexpanthenol cream groups. Nipple pain was measured using the Store scale while trauma was measured with the Champion scale. Analyses were carried out through the Kruskal–Wallis test, Chi-square, ANOVA, and repeated measures ANOVA by using SPSS software ver. 13. Results: The result showed that the mean score of nipple pain and nipple trauma at the prior to intervention stage, third, seventh, and fourteenth days of intervention was not significantly different between three groups. But, repeated measures ANOVA showed a significant difference in comparison of the four time periods of intervention in each group. Conclusion: Results of this study revealed that the lanolin, peppermint, and dexpanthenol medicines had similar therapeutic effects on traumatic nipple. PMID:26744729

  11. Protocol: Testing the Relevance of Acupuncture Theory in the Treatment of Myofascial Pain in the Upper Trapezius Muscle.

    PubMed

    Elsdon, Dale S; Spanswick, Selina; Zaslawski, Chris; Meier, Peter C

    2017-01-01

    A protocol for a prospective single-blind parallel four-arm randomized placebo-controlled trial with repeated measures was designed to test the effects of various acupuncture methods compared with sham. Eighty self-selected participants with myofascial pain in the upper trapezius muscle were randomized into four groups. Group 1 received acupuncture to a myofascial trigger point (MTrP) in the upper trapezius. Group 2 received acupuncture to the MTrP in addition to relevant distal points. Group 3 received acupuncture to the relevant distal points only. Group 4 received a sham treatment to both the MTrP and distal points using a deactivated acupuncture laser device. Treatment was applied four times within 2 weeks with outcomes measured throughout the trial and at 2 weeks and 4 weeks posttreatment. Outcome measurements were a 100-mm visual analog pain scale, SF-36, pressure pain threshold, Neck Disability Index, the Upper Extremity Functional Index, lateral flexion in the neck, McGill Pain Questionnaire, Massachusetts General Hospital Acupuncture Sensation Scale, Working Alliance Inventory (short form), and the Credibility Expectance Questionnaire. Two-way analysis of variance (ANOVA) with repeated measures were used to assess the differences between groups. Copyright © 2017 Medical Association of Pharmacopuncture Institute. Published by Elsevier B.V. All rights reserved.

  12. Error-compensation model for simultaneous measurement of five degrees of freedom motion errors of a rotary axis

    NASA Astrophysics Data System (ADS)

    Bao, Chuanchen; Li, Jiakun; Feng, Qibo; Zhang, Bin

    2018-07-01

    This paper introduces an error-compensation model for our measurement method to measure five motion errors of a rotary axis based on fibre laser collimation. The error-compensation model is established in a matrix form using the homogeneous coordinate transformation theory. The influences of the installation errors, error crosstalk, and manufacturing errors are analysed. The model is verified by both ZEMAX simulation and measurement experiments. The repeatability values of the radial and axial motion errors are significantly suppressed by more than 50% after compensation. The repeatability experiments of five degrees of freedom motion errors and the comparison experiments of two degrees of freedom motion errors of an indexing table were performed by our measuring device and a standard instrument. The results show that the repeatability values of the angular positioning error ε z and tilt motion error around the Y axis ε y are 1.2″ and 4.4″, and the comparison deviations of the two motion errors are 4.0″ and 4.4″, respectively. The repeatability values of the radial and axial motion errors, δ y and δ z , are 1.3 and 0.6 µm, respectively. The repeatability value of the tilt motion error around the X axis ε x is 3.8″.

  13. Repeatability of knee impulsive loading measurements with skin-mounted accelerometers and lower limb surface electromyographic recordings during gait in knee osteoarthritic and asymptomatic individuals

    PubMed Central

    Lyytinen, T.; Bragge, T.; Hakkarainen, M.; Liikavainio, T.; Karjalainen, P.A.; Arokoski, J.P.

    2016-01-01

    Objectives: To determine the repeatability of knee joint impulsive loading measurements with skin-mounted accelerometers (SMAs) and lower limb surface electromyography (EMG) recordings during gait. Methods: Triaxial SMA and EMG from 4 muscles during level and stair walking in nine healthy and nine knee osteoarthritis (OA) subjects were used. The initial peak acceleration (IPA), root mean square (RMS), maximal acceleration transient rate (ATRmax) and mean EMG activity (EMGact) were calculated. The coefficient of variation (CV) and the intraclass correlation coefficient (ICC) were calculated to measure repeatability. Results: The CV and ICC of RMS accelerations ranged from 4.9% to 10.9% and from 0.69 to 0.96 in both study groups during level walking. The CV and ICC of IPA and ATRmax varied from 7.7% to 14.2% and from 0.85 to 0.99 during level and stairs up walking in healthy subjects. The CV and ICC of EMGact ranged from 8.3% to 31.7% and from 0.16 to 0.97 in both study groups. Conclusions: RMS accelerations exhibited good repeatability during walking in healthy and knee OA subjects. The repeatability of EMG measurements was acceptable in healthy subjects depending on the measured muscles. PMID:26944825

  14. TU-F-CAMPUS-I-01: Head and Neck Squamous Cell Carcinoma: Short-Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Y; Fuller, C; Mohamed, A

    2015-06-15

    Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients weremore » scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.« less

  15. Running mechanical alterations during repeated treadmill sprints in hot versus hypoxic environments. A pilot study.

    PubMed

    Girard, Olivier; Brocherie, Franck; Morin, Jean-Benoit; Millet, Grégoire P

    2016-01-01

    We determined if performance and mechanical running alterations during repeated treadmill sprinting differ between severely hot and hypoxic environments. Six male recreational sportsmen (team- and racket-sport background) performed five 5-s sprints with 25-s recovery on an instrumented treadmill, allowing the continuous (step-by-step) measurement of running kinetics/kinematics and spring-mass characteristics. These were randomly conducted in control (CON; 25°C/45% RH, inspired fraction of oxygen = 20.9%), hot (HOT; 38°C/21% RH, inspired fraction of oxygen = 20.9%; end-exercise core temperature: ~38.6°C) and normobaric hypoxic (HYP, 25°C/45% RH, inspired fraction of oxygen = 13.3%/simulated altitude of ~3600 m; end-exercise pulse oxygen saturation: ~84%) environments. Running distance was lower (P < 0.05) in HOT compared to CON and HYP for the first sprint but larger (P < 0.05) sprint decrement score occurred in HYP versus HOT and CON. Compared to CON, the cumulated distance covered over the five sprints was lower (P < 0.01) in HYP but not in HOT. Irrespective of the environmental condition, significant changes occurred from the first to the fifth sprint repetitions (all three conditions compounded) in selected running kinetics (mean horizontal forces, P < 0.01) or kinematics (contact and swing times, both P < 0.001; step frequency, P < 0.001) and spring-mass characteristics (vertical stiffness, P < 0.001; leg stiffness, P < 0.01). No significant interaction between sprint number and condition was found for any mechanical data. Preliminary evidence indicates that repeated-sprint ability is more impaired in hypoxia than in a hot environment, when compared to a control condition. However, as sprints are repeated, mechanical alterations appear not to be exacerbated in severe (heat, hypoxia) environmental conditions.

  16. Changes in contractile properties of muscles receiving repeat injections of botulinum toxin (Botox).

    PubMed

    Fortuna, Rafael; Vaz, Marco Aurélio; Youssef, Aliaa Rehan; Longino, David; Herzog, Walter

    2011-01-04

    Botulinum toxin type A (BTX-A) is a frequently used therapeutic tool to denervate muscles in the treatment of neuromuscular disorders. Although considered safe by the US Food and Drug Administration, BTX-A can produce adverse effects in target and non-target muscles. With an increased use of BTX-A for neuromuscular disorders, the effects of repeat injections of BTX-A on strength, muscle mass and structure need to be known. Therefore, the purpose of this study was to investigate the changes in strength, muscle mass and contractile material in New Zealand White (NZW) rabbits. Twenty NZW rabbits were divided into 4 groups: control and 1, 3 and 6 months of unilateral, repeat injections of BTX-A into the quadriceps femoris. Outcome measures included knee extensor torque, muscle mass and the percentage of contractile material in the quadriceps muscles of the target and non-injected contralateral hindlimbs. Strength in the injected muscles was reduced by 88%, 89% and 95% in the 1, 3 and 6 months BTX-A injected hindlimbs compared to controls. Muscle mass was reduced by 50%, 42% and 31% for the vastus lateralis (VL), rectus femoris (RF) and vastus medialis (VM), respectively, at 1 month, by 68%, 51% and 50% at 3 months and by 76%, 44% and 13% at 6 months. The percentage of contractile material was reduced for the 3 and 6 months animals to 80-64%, respectively, and was replaced primarily by fat. Similar, but less pronounced results were also observed for the quadriceps muscles of the contralateral hindlimbs, suggesting that repeat BTX-A injections cause muscle atrophy and loss of contractile tissue in target muscles and also in non-target muscles that are far removed from the injection site. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Voice Onset Time for the Word-Initial Voiceless Consonant /t/ in Japanese Spasmodic Dysphonia-A Comparison With Normal Controls.

    PubMed

    Yanagida, Saori; Nishizawa, Noriko; Mizoguchi, Kenji; Hatakeyama, Hiromitsu; Fukuda, Satoshi

    2015-07-01

    Voice onset time (VOT) for word-initial voiceless consonants in adductor spasmodic dysphonia (ADSD) and abductor spasmodic dysphonia (ABSD) patients were measured to determine (1) which acoustic measures differed from the controls and (2) whether acoustic measures were related to the pause or silence between the test word and the preceding word. Forty-eight patients with ADSD and nine patients with ABSD, as well as 20 matched normal controls read a story in which the word "taiyo" (the sun) was repeated three times, each differentiated by the position of the word in the sentence. The target of measurement was the VOT for the word-initial voiceless consonant /t/. When the target syllable appeared in a sentence following a comma, or at the beginning of a sentence following a period, the ABSD patients' VOTs were significantly longer than those of the ADSD patients and controls. Abnormal prolongation of the VOTs was related to the pause or silence between the test word and the preceding word. VOTs in spasmodic dysphonia (SD) may vary according to the SD subtype or speaking conditions. VOT measurement was suggested to be a useful method for quantifying voice symptoms in SD. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Assessing atrophy measurement techniques in dementia: Results from the MIRIAD atrophy challenge.

    PubMed

    Cash, David M; Frost, Chris; Iheme, Leonardo O; Ünay, Devrim; Kandemir, Melek; Fripp, Jurgen; Salvado, Olivier; Bourgeat, Pierrick; Reuter, Martin; Fischl, Bruce; Lorenzi, Marco; Frisoni, Giovanni B; Pennec, Xavier; Pierson, Ronald K; Gunter, Jeffrey L; Senjem, Matthew L; Jack, Clifford R; Guizard, Nicolas; Fonov, Vladimir S; Collins, D Louis; Modat, Marc; Cardoso, M Jorge; Leung, Kelvin K; Wang, Hongzhi; Das, Sandhitsu R; Yushkevich, Paul A; Malone, Ian B; Fox, Nick C; Schott, Jonathan M; Ourselin, Sebastien

    2015-12-01

    Structural MRI is widely used for investigating brain atrophy in many neurodegenerative disorders, with several research groups developing and publishing techniques to provide quantitative assessments of this longitudinal change. Often techniques are compared through computation of required sample size estimates for future clinical trials. However interpretation of such comparisons is rendered complex because, despite using the same publicly available cohorts, the various techniques have been assessed with different data exclusions and different statistical analysis models. We created the MIRIAD atrophy challenge in order to test various capabilities of atrophy measurement techniques. The data consisted of 69 subjects (46 Alzheimer's disease, 23 control) who were scanned multiple (up to twelve) times at nine visits over a follow-up period of one to two years, resulting in 708 total image sets. Nine participating groups from 6 countries completed the challenge by providing volumetric measurements of key structures (whole brain, lateral ventricle, left and right hippocampi) for each dataset and atrophy measurements of these structures for each time point pair (both forward and backward) of a given subject. From these results, we formally compared techniques using exactly the same dataset. First, we assessed the repeatability of each technique using rates obtained from short intervals where no measurable atrophy is expected. For those measures that provided direct measures of atrophy between pairs of images, we also assessed symmetry and transitivity. Then, we performed a statistical analysis in a consistent manner using linear mixed effect models. The models, one for repeated measures of volume made at multiple time-points and a second for repeated "direct" measures of change in brain volume, appropriately allowed for the correlation between measures made on the same subject and were shown to fit the data well. From these models, we obtained estimates of the distribution of atrophy rates in the Alzheimer's disease (AD) and control groups and of required sample sizes to detect a 25% treatment effect, in relation to healthy ageing, with 95% significance and 80% power over follow-up periods of 6, 12, and 24months. Uncertainty in these estimates, and head-to-head comparisons between techniques, were carried out using the bootstrap. The lateral ventricles provided the most stable measurements, followed by the brain. The hippocampi had much more variability across participants, likely because of differences in segmentation protocol and less distinct boundaries. Most methods showed no indication of bias based on the short-term interval results, and direct measures provided good consistency in terms of symmetry and transitivity. The resulting annualized rates of change derived from the model ranged from, for whole brain: -1.4% to -2.2% (AD) and -0.35% to -0.67% (control), for ventricles: 4.6% to 10.2% (AD) and 1.2% to 3.4% (control), and for hippocampi: -1.5% to -7.0% (AD) and -0.4% to -1.4% (control). There were large and statistically significant differences in the sample size requirements between many of the techniques. The lowest sample sizes for each of these structures, for a trial with a 12month follow-up period, were 242 (95% CI: 154 to 422) for whole brain, 168 (95% CI: 112 to 282) for ventricles, 190 (95% CI: 146 to 268) for left hippocampi, and 158 (95% CI: 116 to 228) for right hippocampi. This analysis represents one of the most extensive statistical comparisons of a large number of different atrophy measurement techniques from around the globe. The challenge data will remain online and publicly available so that other groups can assess their methods. Copyright © 2015. Published by Elsevier Inc.

  19. Assessing atrophy measurement techniques in dementia: Results from the MIRIAD atrophy challenge

    PubMed Central

    Cash, David M.; Frost, Chris; Iheme, Leonardo O.; Ünay, Devrim; Kandemir, Melek; Fripp, Jurgen; Salvado, Olivier; Bourgeat, Pierrick; Reuter, Martin; Fischl, Bruce; Lorenzi, Marco; Frisoni, Giovanni B.; Pennec, Xavier; Pierson, Ronald K.; Gunter, Jeffrey L.; Senjem, Matthew L.; Jack, Clifford R.; Guizard, Nicolas; Fonov, Vladimir S.; Collins, D. Louis; Modat, Marc; Cardoso, M. Jorge; Leung, Kelvin K.; Wang, Hongzhi; Das, Sandhitsu R.; Yushkevich, Paul A.; Malone, Ian B.; Fox, Nick C.; Schott, Jonathan M.; Ourselin, Sebastien

    2015-01-01

    Structural MRI is widely used for investigating brain atrophy in many neurodegenerative disorders, with several research groups developing and publishing techniques to provide quantitative assessments of this longitudinal change. Often techniques are compared through computation of required sample size estimates for future clinical trials. However interpretation of such comparisons is rendered complex because, despite using the same publicly available cohorts, the various techniques have been assessed with different data exclusions and different statistical analysis models. We created the MIRIAD atrophy challenge in order to test various capabilities of atrophy measurement techniques. The data consisted of 69 subjects (46 Alzheimer's disease, 23 control) who were scanned multiple (up to twelve) times at nine visits over a follow-up period of one to two years, resulting in 708 total image sets. Nine participating groups from 6 countries completed the challenge by providing volumetric measurements of key structures (whole brain, lateral ventricle, left and right hippocampi) for each dataset and atrophy measurements of these structures for each time point pair (both forward and backward) of a given subject. From these results, we formally compared techniques using exactly the same dataset. First, we assessed the repeatability of each technique using rates obtained from short intervals where no measurable atrophy is expected. For those measures that provided direct measures of atrophy between pairs of images, we also assessed symmetry and transitivity. Then, we performed a statistical analysis in a consistent manner using linear mixed effect models. The models, one for repeated measures of volume made at multiple time-points and a second for repeated “direct” measures of change in brain volume, appropriately allowed for the correlation between measures made on the same subject and were shown to fit the data well. From these models, we obtained estimates of the distribution of atrophy rates in the Alzheimer's disease (AD) and control groups and of required sample sizes to detect a 25% treatment effect, in relation to healthy ageing, with 95% significance and 80% power over follow-up periods of 6, 12, and 24 months. Uncertainty in these estimates, and head-to-head comparisons between techniques, were carried out using the bootstrap. The lateral ventricles provided the most stable measurements, followed by the brain. The hippocampi had much more variability across participants, likely because of differences in segmentation protocol and less distinct boundaries. Most methods showed no indication of bias based on the short-term interval results, and direct measures provided good consistency in terms of symmetry and transitivity. The resulting annualized rates of change derived from the model ranged from, for whole brain: − 1.4% to − 2.2% (AD) and − 0.35% to − 0.67% (control), for ventricles: 4.6% to 10.2% (AD) and 1.2% to 3.4% (control), and for hippocampi: − 1.5% to − 7.0% (AD) and − 0.4% to − 1.4% (control). There were large and statistically significant differences in the sample size requirements between many of the techniques. The lowest sample sizes for each of these structures, for a trial with a 12 month follow-up period, were 242 (95% CI: 154 to 422) for whole brain, 168 (95% CI: 112 to 282) for ventricles, 190 (95% CI: 146 to 268) for left hippocampi, and 158 (95% CI: 116 to 228) for right hippocampi. This analysis represents one of the most extensive statistical comparisons of a large number of different atrophy measurement techniques from around the globe. The challenge data will remain online and publicly available so that other groups can assess their methods. PMID:26275383

  20. Feasibility of overnight closed-loop control based on hourly blood glucose measurements.

    PubMed

    Patte, Caroline; Pleus, Stefan; Galley, Paul; Weinert, Stefan; Haug, Cornelia; Freckmann, Guido

    2012-07-01

    Safe and effective closed-loop control (artificial pancreas) is the ultimate goal of insulin delivery. In this study, we examined the performance of a closed-loop control algorithm used for the overnight time period to safely achieve a narrow target range of blood glucose (BG) concentrations prior to breakfast. The primary goal was to compare the quality of algorithm control during repeated overnight experiments. Twenty-three subjects with type 1 diabetes performed 2 overnight experiments on each of three visits at the study site, resulting in 138 overnight experiments. On the first evening, the subject's insulin therapy was applied; on the second, the insulin was delivered by an algorithm based on subcutaneous continuous glucose measurements (including meal control) until midnight. Overnight closed-loop control was applied between midnight and 6 a.m. based on hourly venous BG measurements during the first and second nights. The number of BG values within the target range (90-150 mg/dl) increased from 52.9% (219 out of 414 measurements) during the first nights to 72.2% (299 out of 414 measurements) during the second nights (p < .001, χ²-test). The occurrence of hypoglycemia interventions was reduced from 14 oral glucose interventions, the latest occurring at 2:36 a.m. during the first nights, to 1 intervention occurring at 1:02 a.m. during the second nights (p < .001, χ²-test). Overnight controller performance improved when optimized initial control was given; this was suggested by the better metabolic control during the second night. Adequate controller run-in time seems to be important for achieving good overnight control. In addition, the findings demonstrate that hourly BG data are sufficient for the closed-loop control algorithm tested to achieve appropriate glycemic control. © 2012 Diabetes Technology Society.

Top