NASA Astrophysics Data System (ADS)
Ide, T. S.; Pollard, D. D.; Orr, F. M.
2009-12-01
Coalbed fires are uncontrolled subsurface fires that occur around the world. These fires are believed to be significant contributors to annual CO2 emissions. Although many of these fires have been burning for decades, researchers have only recently begun to investigate physical mechanisms that control fire behavior. One aspect that is poorly characterized is the relationship between subsurface combustion and surface fissures. At the surface above many fires, long, wide fissures are observed. At a coalbed fire near Durango, Colorado, these fissures form systematic orthogonal patterns that align with regional joints in the Upper Cretaceous Fruitland Formation. Understanding the mechanisms that form and widen these fissures is important, as the fissures are believed to play vital roles in sustaining the combustion in the subsurface by acting as chimneys for the escaping gases and conduits for incoming oxygen. In some of the coalbed fire simulation models available today, these fissures are treated as fixed boundary conditions, but we argue, using field observations and simulation results, that there exists a relationship between the location and magnitude of subsidence caused by the fire and the opening of fissures. Four distinct types of fissures are observed over the coalbed fire near Durango, CO. These fissures are termed ‘molehill’, ‘plateau’, ‘gaping’, and ‘narrow’ based on their surface appearances. Molehill fissures are marked by surface depressions on either side, causing the strata around the opening to form an apex towards the center of the fissure. Plateau fissures show a steep vertical offset on only one side with minimal horizontal displacement. Gaping fissures and narrow fissures are predominantly opening with little evidence for vertical displacements. Gaping fissures are defined as fissures with wide apertures (0.3 ~ 1.5m), while narrow fissures have apertures on the order of centimeters. A boundary element method code was used to show that relationships exist between the surface displacement magnitudes and directions, and the subsurface subsidence due to coal combustion. Subsidence variables include the length, magnitude, depth and location of subsidence, as well as the weight of the overburden. Each of the four types of surface features was related to these subsurface subsidence variables using a set of dimensionless curves. The simulation results were validated with field measurements from a nearby outcrop and borehole drilling. The possibility of using InSAR data to further constrain these model results is being investigated. The simulated dimensionless curves establish a useful rules of thumb to aid the interpretation and mitigation of coal fires, since these curves can be used to relate a surface fissures aperture, an easily measurable parameter, to variables such as the magnitude of subsurface subsidence that are harder to observe
Modeling the Hydrologic Response to Changes in Groundcover Conditions Caused by Fire Disturbances
NASA Astrophysics Data System (ADS)
Kikinzon, E.; Atchley, A. L.; Coon, E.; Middleton, R. S.
2016-12-01
Climate change and fire suppression increase wildfire activity, which alters ecosystem functions and can significantly impact hydrological response. Both wildfire and prescribed burns reduce groundcover, affect top layers of subsurface, and change the structure of overland flow pathways. To understand respective effects on surface and subsurface hydrology, it is imperative to accurately represent surface-subsurface interface pre and post-fire, and to model physical processes in groundcover components. We show mechanistic models used to describe physics in two key types of groundcover, litter and duff, in Advanced Terrestrial Simulator (ATS). Litter is considered to be a part of vegetative canopy covering the surface. It has associated water storage capacity, which allows simulating interception and drainage, and its thickness is used to evaluate surface roughness with potential effect of slowing overland flow compared to bare soil. Duff on the other hand is incorporated into the subsurface, thus requiring meshing and discretization capability to support complex geometries including pinchouts, which is necessary both for achieving desired mesh resolution and portraying bare soil patches without adversely affecting the time scale. As part of the subsurface, duff has its own hydrologic and water retention properties used to resolve infiltration and saturation limited runoff generation, run on, and infiltration processes. This enables the use of ATS for fine scale modeling of integrated hydrology with adequate representation of groundcover influence. To isolate the impact of changing groundcover, we consider a simple hill slope and study the hydrological response to varying amount and geometries of groundcover. To cover landscape characteristics produced by a wide variety of fire conditions, from high intensity to low intensity fire impacts, we simulate hydrologic response to precipitation events over a number of typical geometries and with fine control over amounts of two described types of groundcover. We then analyze hydrological sensitivity to presence or absence of particular groundcover types, their respective patchiness, and possible changes in overland flow pathways.
NASA Astrophysics Data System (ADS)
Vasterling, Margarete; Schloemer, Stefan; Fischer, Christian; Ehrler, Christoph
2010-05-01
Spontaneous combustion of coal and resulting coal fires lead to very high temperatures in the subsurface. To a large amount the heat is transferred to the surface by convective and conductive transport inducing a more or less pronounced thermal anomaly. During the past decade satellite-based infrared-imaging (ASTER, MODIS) was the method of choice for coal fire detection on a local and regional scale. However, the resolution is by far too low for a detailed analysis of single coal fires which is essential prerequisite for corrective measures (i.e. fire fighting) and calculation of carbon dioxide emission based on a complex correlation between energy release and CO2 generation. Consequently, within the framework of the Sino-German research project "Innovative Technologies for Exploration, Extinction and Monitoring of Coal Fires in Northern China", a new concept was developed and successfully tested. An unmanned aerial vehicle (UAV) was equipped with a lightweight camera for thermografic (resolution 160 by 120 pixel, dynamic range -20 to 250°C) and for visual imaging. The UAV designed as an octocopter is able to hover at GPS controlled waypoints during predefined flight missions. The application of a UAV has several advantages. Compared to point measurements on the ground the thermal imagery quickly provides the spatial distribution of the temperature anomaly with a much better resolution. Areas otherwise not accessible (due to topography, fire induced cracks, etc.) can easily be investigated. The results of areal surveys on two coal fires in Xinjiang are presented. Georeferenced thermal and visual images were mosaicked together and analyzed. UAV-born data do well compared to temperatures measured directly on the ground and cover large areas in detail. However, measuring surface temperature alone is not sufficient. Simultaneous measurements made at the surface and in roughly 15cm depth proved substantial temperature gradients in the upper soil. Thus the temperature measured at the surface underestimates the energy emitted by the subsurface coal fire. In addition, surface temperature is strongly influenced by solar radiation and the prevailing ambient conditions (wind, temperature, humidity). As a consequence there is no simple correlation between surface and subsurface soil temperature. Efforts have been made to set up a coupled energy transport and energy balance model for the near surface considering thermal conduction, solar irradiation, thermal radiative energy and ambient temperature so far. The model can help to validate space-born and UAV-born thermal imagery and link surface to subsurface temperature but depends on in-situ measurements for input parameter determination and calibration. Results obtained so far strongly necessitate the integration of different data sources (in-situ / remote; point / area; local / medium scale) to obtain a reliable energy release estimation which is then used for coal fire characterization.
ESTIMATION OF NEAR SUBSURFACE COAL FIRE GAS EMISSIONS BASED ON GEOPHYSICAL INVESTIGATIONS
NASA Astrophysics Data System (ADS)
Chen-Brauchler, D.; Meyer, U.; Schlömer, S.; Kus, J.; Gundelach, V.; Wuttke, M.; Fischer, C.; Rueter, H.
2009-12-01
Spontaneous and industrially caused subsurface coal fires are worldwide disasters that destroy coal resources, cause air pollution and emit a large amount of green house gases. Especially in developing countries, such as China, India and Malaysia, this problem has intensified over the last 15 years. In China alone, 10 to 20 million tons of coal are believed to be lost in uncontrolled coal fires. The cooperation of developing countries and industrialized countries is needed to enforce internationally concerted approaches and political attention towards the problem. The Clean Development Mechanism (CDM) under the framework of the Kyoto Protocol may provide an international stage for financial investment needed to fight the disastrous situation. A Sino-German research project for coal fire exploration, monitoring and extinction applied several geophysical approaches in order to estimate the annual baseline especially of CO2 emissions from near subsurface coal fires. As a result of this project, we present verifiable methodologies that may be used in the CDM framework to estimate the amount of CO2 emissions from near subsurface coal fires. We developed three possibilities to approach the estimation based on (1) thermal energy release, (2) geological and geometrical determinations as well as (3) direct gas measurement. The studies involve the investigation of the physical property changes of the coal seam and bedrock during different burning stages of a underground coal fire. Various geophysical monitoring methods were applied from near surface to determine the coal volume, fire propagation, temperature anomalies, etc.
NASA Astrophysics Data System (ADS)
Gupta, Nishant; Syed, Tajdarul H.; Athiphro, Ashiihrii
2013-10-01
Coal fires in the Jharia coalfield pose a serious threat to India's vital resource of primary coking coal and the regional environment. In order to undertake effective preventative measures, it is critical to detect the occurrence of subsurface coal fires and to monitor the extent of the existing ones. In this study, Differential Interferometric Synthetic Aperature Radar (DInSAR) technique has been utilized to monitor subsurface coal fires in the Jharia coalfield. Results showed that majority of the coal fire-related subsidence were concentrated on the eastern and western boundaries of the coalfield. The magnitude of subsidence observed was classified into high (10-27.8 mm), low (0-10 mm) and upliftment (-10-0 mm). The results were strongly supported by in situ observations and satellite-based thermal imagery analysis. Major subsidence was observed in the areas with repeated sightings of coal fire. Further, the study highlighted on the capability of the methodology for predicting potential coal fire zones on the basis of land surface subsidence only. The results from this study have major implications for demarcating the hazardous coal fire areas as well as effective implementation of public safety measures.
NASA Astrophysics Data System (ADS)
Chang, Chun-Hung; Fried, Nathaniel M.
2016-02-01
Infrared lasers have been used in combination with applied cooling methods to preserve superficial skin layers during cosmetic surgery. Similarly, combined laser irradiation and tissue cooling may also allow development of minimally invasive laser therapies beyond dermatology. This study compares diffusing, side-firing, and radial delivery laser balloon catheter designs for creation of subsurface lesions in tissue, ex vivo, using a near-IR laser and applied contact cooling. An Ytterbium fiber laser with 1075 nm wavelength delivered energy through custom built 18 Fr (6-mm-OD) balloon catheters incorporating either 10-mm-long diffusing fiber tip, 90 degree side-firing fiber, or radial delivery cone mirror, through a central lumen. A chilled solution was flowed through a separate lumen into 9-mm-diameter balloon to keep probe cooled at 7°C. Porcine liver tissue samples were used as preliminary tissue model for immediate observation of thermal lesion creation. The diffusing fiber produced subsurface thermal lesions measuring 49.3 +/- 10.0 mm2 and preserved 0.8 +/- 0.1 mm of surface tissue. The side-firing fiber produced subsurface thermal lesions of 2.4 +/- 0.9 mm2 diameter and preserved 0.5 +/- 0.1 mm of surface tissue. The radial delivery probe assembly failed to produce subsurface thermal lesions, presumably due to the small effective spot diameter at the tissue surface, which limited optical penetration depth. Optimal laser power and irradiation time measured 15 W and 100 s for diffusing fiber and 1.4 W and 20 s, for side-firing fiber, respectively. Diffusing and side-firing laser balloon catheter designs provided subsurface thermal lesions in tissue. However, the divergent laser beam in both designs limited the ability to preserve a thicker layer of tissue surface. Further optimization of laser and cooling parameters may be necessary to preserve thicker surface tissue layers.
The effects of fire on subsurface archaeological materials [Chapter 7
Elizabeth A. Oster; Samantha Ruscavage-Barz; Michael L. Elliott
2012-01-01
In this chapter, we concentrate on the effects of fire on subsurface archaeological deposits: the matrix containing post-depositional fill, artifacts, ecofactual data, dating samples, and other cultural and noncultural materials. In order to provide a context for understanding these data, this paper provides a summary of previous research about the potential effects of...
Quantifying Fire Impact on Alaskan Tundra from Satellite Observations and Field Measurements
NASA Astrophysics Data System (ADS)
Loboda, T. V.; Chen, D.; He, J.; Jenkins, L. K.
2017-12-01
Wildfire is a major disturbance agent in Alaskan tundra. The frequency and extent of fire events obtained from paleo, management, and satellite records may yet underestimate the scope of tundra fire impact. Field measurements, collected within the NASA's ABoVE campaign, revealed unexpectedly shallow organic soils ( 15 cm) across all sampled sites of the Noatak valley with no significant difference between recently burned and unburned sites. In typical small and medium-sized tundra burns vegetation recovers rapidly and scars are not discernable in 30 m optical satellite imagery by the end of the first post-fire season. However, field observations indicate that vegetation and subsurface characteristics within fire scars of different ages vary across the landscape. In this study we develop linkages between fire-induced changes to tundra and satellite-based observations from optical, thermal, and microwave imagers to enable extrapolation of in-situ observations to cover the full extent of Alaskan tundra. Our results show that recent ( 30 years) fire history can be reconstructed from optical observations (R2 0.65, p<0.001) within a specific narrow temporal window or thermal signatures (R2 0.54, p < 0.001), in both cases controlled for slope and southern exposure. Using microwave SAR imagery fire history can be determined for 4 years post fire primarily due to increased soil moisture at burned sites. Field measurements suggest that the relatively quick SAR signal dissipation results from more even distribution of surface moisture through the soil column with increases in Active Layer Thickness (ALT). Similar to previous long-term field studies we find an increase in shrub fraction and shrub height within burns over time at the landscape scale; however, the strength and significance of the relationship between shrub fraction and time since fire is governed by burn severity with more severe burns predictably (p < 0.01) resulting in higher post-fire shrub cover. Although reasonably well-correlated to each other when adjusted for topography (R2 0.35, p < 0.001), neither ALT nor soil temperature can be directly linked to optical or thermal brightness observations with acceptable statistical significance, necessitating a more complex modeling environment for wall-to-wall mapping of subsurface parameters.
Evaluating post-wildfire hydrologic recovery using ParFlow in southern California
NASA Astrophysics Data System (ADS)
Lopez, S. R.; Kinoshita, A. M.; Atchley, A. L.
2016-12-01
Wildfires are naturally occurring hazards that can have catastrophic impacts. They can alter the natural processes within a watershed, such as surface runoff and subsurface water storage. Generally, post-fire hydrologic models are either one-dimensional, empirically-based models, or two-dimensional, conceptually-based models with lumped parameter distributions. These models are useful in providing runoff measurements at the watershed outlet; however, do not provide distributed hydrologic simulation at each point within the watershed. This research demonstrates how ParFlow, a three-dimensional, distributed hydrologic model can simulate post-fire hydrologic processes by representing soil burn severity (via hydrophobicity) and vegetation recovery as they vary both spatially and temporally. Using this approach, we are able to evaluate the change in post-fire water components (surface flow, lateral flow, baseflow, and evapotranspiration). This model is initially developed for a hillslope in Devil Canyon, burned in 2003 by the Old Fire in southern California (USA). The domain uses a 2m-cell size resolution over a 25 m by 25 m lateral extent. The subsurface reaches 2 m and is assigned a variable cell thickness, allowing an explicit consideration of the soil burn severity throughout the stages of recovery and vegetation regrowth. Vegetation regrowth is incorporated represented by satellite-based Enhanced Vegetation Index (EVI) products. The pre- and post-fire surface runoff, subsurface storage, and surface storage interactions are evaluated and will be used as a basis for developing a watershed-scale model. Long-term continuous simulations will advance our understanding of post-fire hydrological partitioning between water balance components and the spatial variability of watershed processes, providing improved guidance for post-fire watershed management.
Evidence for nonuniform permafrost degradation after fire in boreal landscapes
Minsley, Burke J.; Pastick, Neal J.; Wylie, Bruce K.; Brown, Dana R.N.; Kass, M. Andy
2016-01-01
Fire can be a significant driver of permafrost change in boreal landscapes, altering the availability of soil carbon and nutrients that have important implications for future climate and ecological succession. However, not all landscapes are equally susceptible to fire-induced change. As fire frequency is expected to increase in the high latitudes, methods to understand the vulnerability and resilience of different landscapes to permafrost degradation are needed. We present a combination of multiscale remote sensing, geophysical, and field observations that reveal details of both near-surface (<1 m) and deeper (>1 m) impacts of fire on permafrost. Along 11 transects that span burned-unburned boundaries in different landscape settings within interior Alaska, subsurface electrical resistivity and nuclear magnetic resonance data indicate locations where permafrost appears to be resilient to disturbance from fire, areas where warm permafrost conditions exist that may be most vulnerable to future change, and also areas where permafrost has thawed. High-resolution geophysical data corroborate remote sensing interpretations of near-surface permafrost and also add new high-fidelity details of spatial heterogeneity that extend from the shallow subsurface to depths of about 10 m. Results show that postfire impacts on permafrost can be variable and depend on multiple factors such as fire severity, soil texture, soil moisture, and time since fire.
Geophysical evidence for non-uniform permafrost degradation after fire across boreal landscapes
NASA Astrophysics Data System (ADS)
Minsley, B. J.; Pastick, N. J.; Wylie, B. K.; Brown, D. N.; Kass, A.
2015-12-01
Fire can be a significant driver of permafrost change in boreal landscapes, altering the availability of soil carbon and nutrients that have important implications for future climate and ecological succession. However, not all landscapes are equally susceptible to fire-induced change. As fire frequency is expected to increase in the high latitudes, methods to understand the vulnerability and resilience of different landscapes to permafrost degradation are needed. We present a combination of multi-scale remote sensing, geophysical, and field observations that reveal details of both near-surface (<1 m) and deeper impacts of fire on permafrost. Along 11 transects that span burned-unburned boundaries in different landscape settings within interior Alaska, subsurface imaging indicates locations where permafrost appears to be resilient to disturbance from fire, areas where warm permafrost conditions exist that may be most vulnerable to future change, and also where permafrost has thawed. High-resolution geophysical data corroborate remote sensing interpretations of near-surface permafrost, and also add new high-fidelity details of spatial heterogeneity that extend from the shallow subsurface to depths of about 10 m. Data collected along each transect include observations of active layer thickness (ALT), organic layer thickness (OLT), plant species cover, electrical resistivity tomography (ERT), and downhole Nuclear Magnetic Resonance (NMR) measurements. Results show that post-fire impacts on permafrost can be variable, and depend on multiple factors such as fire severity, soil texture, and soil moisture.
Modeling post-wildfire hydrological processes with ParFlow
NASA Astrophysics Data System (ADS)
Escobar, I. S.; Lopez, S. R.; Kinoshita, A. M.
2017-12-01
Wildfires alter the natural processes within a watershed, such as surface runoff, evapotranspiration rates, and subsurface water storage. Post-fire hydrologic models are typically one-dimensional, empirically-based models or two-dimensional, conceptually-based models with lumped parameter distributions. These models are useful for modeling and predictions at the watershed outlet; however, do not provide detailed, distributed hydrologic processes at the point scale within the watershed. This research uses ParFlow, a three-dimensional, distributed hydrologic model to simulate post-fire hydrologic processes by representing the spatial and temporal variability of soil burn severity (via hydrophobicity) and vegetation recovery. Using this approach, we are able to evaluate the change in post-fire water components (surface flow, lateral flow, baseflow, and evapotranspiration). This work builds upon previous field and remote sensing analysis conducted for the 2003 Old Fire Burn in Devil Canyon, located in southern California (USA). This model is initially developed for a hillslope defined by a 500 m by 1000 m lateral extent. The subsurface reaches 12.4 m and is assigned a variable cell thickness to explicitly consider soil burn severity throughout the stages of recovery and vegetation regrowth. We consider four slope and eight hydrophobic layer configurations. Evapotranspiration is used as a proxy for vegetation regrowth and is represented by the satellite-based Simplified Surface Energy Balance (SSEBOP) product. The pre- and post-fire surface runoff, subsurface storage, and surface storage interactions are evaluated at the point scale. Results will be used as a basis for developing and fine-tuning a watershed-scale model. Long-term simulations will advance our understanding of post-fire hydrological partitioning between water balance components and the spatial variability of watershed processes, providing improved guidance for post-fire watershed management. In reference to the presenter, Isabel Escobar: Research is funded by the NASA-DIRECT STEM Program. Travel expenses for this presentation is funded by CSU-LSAMP. CSU-LSAMP is supported by the National Science Foundation under Grant # HRD-1302873 and the CSU Office of Chancellor.
The decommissioned Wurtsmith Air Force Base former Fire Training Cell (FT-02) facility has been the focus of several geophysical investigations. After several decades of fire training exercises, significant amounts of hydrocarbons and some solvents seeped into the subsurface cont...
The decommissioned Wurtsmith Air Force Base former Fire Training Cell (FT-02) facility has been the focus of several geophysical investigations. After several decades of fire training exercises, significant amounts of hydrocarbons and some solvents seeped into the Subsurface cont...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-07
... soil amendments or dryland farming activities (Roberts 2009, p. 2). Subsurface Water Flow That Creates... protection to reduce the following threats: habitat destruction and fragmentation from urban and agricultural...; fire suppression practices (including discing and plowing to remove weeds and create fire breaks...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
This decision document presents the Air Force Center for Environmental Excellence (AFCEE) selected remedial action decisions for contaminant source areas at the following Areas of Contamination (AOCs) at the Massachusetts Military Reservation (MMR) in Barnstable County on Cape Cod, Massachusetts: Fire Training Area No. 2 and Landfill No. 2 (FTA-2/LF-2); Petroleum Fuels Storage Area, Fuel Spill No. 10, and Fuel Spill No. 11 (PFSA/FS-10/FS-11); Storm Drainage Ditch No. 2, Fuel Spill No. 6, and Fuel Spill No. 8 (SD-2/FS-6/FS-8); Storm Drainage Ditch No. 2, Fire Training Area No. 3, and Coal Storage Yard No. 4 (SF-3/FTA-3/CY-4); Storm Drainage Ditch No.more » 4 (SD-4); and Storm Drainage Ditch No. 5 and Fuel Spill No. 5 (SD-5/FS-5). The selected remedy for AOC FTA-2/LF-2 is Biosparging with Ambient Air Monitoring. This remedial action is a source control action that addresses leaching of organic compounds to groundwater, the principal known threat at AOC FTA-2/LF-2. It consists of designing, constructing, and operating a biosparging treatment system, maintaining institutional controls, and five-year reviews of remedy protectiveness. The remedy reduces the release of contaminants from subsurface soils by treating subsurface soils to meet protective cleanup levels.« less
NASA Astrophysics Data System (ADS)
Klos, P. Z.; Goulden, M.; Riebe, C. S.; Tague, C.; O'Geen, A. T.; Flinchum, B. A.; Safeeq, M.; Conklin, M. H.; Hart, S. C.; Asefaw Berhe, A.; Hartsough, P. C.; Holbrook, S.; Bales, R. C.
2017-12-01
Enhanced understanding of subsurface water storage, and the below-ground architecture and processes that create it, will advance our ability to predict how the impacts of climate change - including drought, forest mortality, wildland fire, and strained water security - will take form in the decades to come. Previous research has examined the importance of plant-accessible water in soil, but in upland landscapes within Mediterranean climates the soil is often only the upper extent of subsurface water storage. We draw insights from both this previous research and a case study of the Southern Sierra Critical Zone Observatory to: define attributes of subsurface storage, review observed patterns in its distribution, highlight nested methods for its estimation across scales, and showcase the fundamental processes controlling its formation. We observe that forest ecosystems at our sites subsist on lasting plant-accessible stores of subsurface water during the summer dry period and during multi-year droughts. This indicates that trees in these forest ecosystems are rooted deeply in the weathered, highly porous saprolite, which reaches up to 10-20 m beneath the surface. This confirms the importance of large volumes of subsurface water in supporting ecosystem resistance to climate and landscape change across a range of spatiotemporal scales. This research enhances the ability to predict the extent of deep subsurface storage across landscapes; aiding in the advancement of both critical zone science and the management of natural resources emanating from similar mountain ecosystems worldwide.
Smouldering Subsurface Fires in the Earth System
NASA Astrophysics Data System (ADS)
Rein, Guillermo
2010-05-01
Smouldering fires, the slow, low-temperature, flameless form of combustion, are an important phenomena in the Earth system. These fires propagate slowly through organic layers of the forest ground and are responsible for 50% or more of the total biomass consumed during wildfires. Only after the 2002 study of the 1997 extreme haze event in South-East Asia, the scientific community recognised the environmental and economic threats posed by subsurface fires. This was caused by the spread of vast biomass fires in Indonesia, burning below the surface for months during the El Niño climate event. It has been calculated that these fires released between 0.81 and 2.57 Gton of carbon gases (13-40% of global emissions). Large smouldering fires are rare events at the local scale but occur regularly at a global scale. Once ignited, they are particularly difficult to extinguish despite extensive rains or fire-fighting attempts and can persist for long periods of time (months, years) spreading over very extensive areas of forest and deep into the soil. Indeed, these are the oldest continuously burning fires on Earth. Earth scientists are interested in smouldering fires because they destroy large amounts of biomass and cause greater damage to the soil ecosystem than flaming fires do. Moreover, these fires cannot be detected with current satellite remote sensing technologies causing inconsistencies between emission inventories and model predictions. Organic soils sustain smouldering fire (hummus, duff, peat and coal) which total carbon pool exceeds that of the world's forests or the atmosphere. This have important implications for climate change. Warmer temperatures at high latitudes are resulting in unprecedented permafrost thaw that is leaving large soil carbon pools exposed to fires. Because the CO2 flux from peat fires has been measured to be about 3000 times larger that the natural degradation flux, permafrost thaw is a risk for greater carbon release by fire and subsequently influence carbon-climate feedbacks. This presentation will revise the current knowledge on smouldering fires in the Earth system regarding ignition, spread patterns and emissions. It will explain the key differences between shallow and deep fires, and flaming fires.
Post-fire geomorphic response in steep, forested landscapes: Oregon Coast Range, USA
NASA Astrophysics Data System (ADS)
Jackson, Molly; Roering, Joshua J.
2009-06-01
The role of fire in shaping steep, forested landscapes depends on a suite of hydrologic, biologic, and geological characteristics, including the propensity for hydrophobic soil layers to promote runoff erosion during subsequent rainfall events. In the Oregon Coast Range, several studies postulate that fire primarily modulates sediment production via root reinforcement and shallow landslide susceptibility, although few studies have documented post-fire geomorphic response. Here, we describe field observations and topographic analyses for three sites in the central Oregon Coast Range that burned in 1999, 2002, and 2003. The fires generated strongly hydrophobic soil layers that did not promote runoff erosion because the continuity of the layers was interrupted by pervasive discontinuities that facilitated rapid infiltration. At each of our sites, fire generated significant colluvial transport via dry ravel, consistent with other field-based studies in the western United States. Fire-driven dry ravel accumulation in low-order valleys of our Sulphur Creek site equated to a slope-averaged landscape lowering of 2.5 mm. Given Holocene estimates of fire frequency, these results suggest that fire may contribute 10-20% of total denudation across steep, dissected portions of the Oregon Coast Range. In addition, we documented more rapid decline of root strength at our sites than has been observed after timber harvest, suggesting that root strength was compromised prior to fire or that intense heat damaged roots in the shallow subsurface. Given that fire frequencies in the Pacific Northwest are predicted to increase with continued climate change, our findings highlight the importance of fire-induced dry ravel and post-fire debris flow activity in controlling sediment delivery to channels.
NASA Astrophysics Data System (ADS)
Trinh, Le Hung; Zablotskii, V. R.
2017-12-01
The Khanh Hoa coal mine is a surface coal mine in the Thai Nguyen province, which is one of the largest deposits of coal in the Vietnam. Numerous reasons such as improper mining techniques and policy, as well as unauthorized mining caused surface and subsurface coal fire in this area. Coal fire is a dangerous phenomenon which affects the environment seriously by releasing toxic fumes which causes forest fires, and subsidence of infrastructure surface. This article presents study on the application of LANDSAT multi-temporal thermal infrared images, which help to detect coal fire. The results obtained in this study can be used to monitor fire zones so as to give warnings and solutions to prevent coal fire.
The Impact of Fire on Active Layer Thicknes
NASA Astrophysics Data System (ADS)
Schaefer, K. M.; Parsekian, A.; Natali, S.; Ludwig, S.; Michaelides, R. J.; Zebker, H. A.; Chen, J.
2016-12-01
Fire influences permafrost thermodynamics by darkening the surface to increase solar absorption and removing insulating moss and organic soil, resulting in an increase in Active Layer Thickness (ALT). The summer of 2015 was one of the worst fire years on record in Alaska with multiple fires in the Yukon-Kuskokwim (YK) Delta. To understand the impacts of fire on permafrost, we need large-scale, extensive measurements of ALT both within and outside the fire zones. In August 2016, we surveyed ALT across multiple fire zones in the YK Delta using Ground Penetrating Radar (GPR) and mechanical probing. GPR uses pulsed, radio-frequency electromagnetic waves to noninvasively image the subsurface and is an effective tool to quickly map ALT over large areas. We supplemented this ALT data with measurements of Volumetric Water Content (VWC), Organic Layer Thickness (OLT), and burn severity. We quantified the impacts of fire by statistically comparing the measurements inside and outside the fire zones and statistically regressing ALT against VWC, change in OLT, and burn severity.
NASA Astrophysics Data System (ADS)
Xue, X. H.; Chang, S.; Yuan, L. Y.
2017-08-01
Riverbanks are important boundaries for the nutrient cycling between lands and freshwaters. This research aimed to explore effects of different land management methods on the soil nutrient concentration and distribution at riverbanks. Soils from the reed-covered riverbanks of middle Yangtze River were studied, including the soils respectively undergoing systematic agriculture (gathering young tender shoots, reaping reed straws, and burning residual straws), fires and no disturbances. Results showed that the agricultural activities sharply decreased the contents of soil organic matter (SOM), N, P and K in subsurface soils but less decreased the surface SOM, N and K contents, whereas phosphorus were evidently decreased at both surface and subsurface layers. In contrast, the single application of fires caused a marked increase of SOM, N, P and K contents in both surface and subsurface soils but had little impacts on soil nutrient distributions. Soils under all the three conditions showed a relative increase of soil nutrients at riverbank foot. This comparative study indicated that the different or even contrary effects of riverbank management practices on soil nutrient statuses should be carefully taken into account when assessing the ecological effects of management practices.
Oliveira-Filho, Eduardo C; Brito, Darlan Q; Dias, Zelia M B; Guarieiro, Mayara S; Carvalho, Esther L; Fascineli, Maria L; Niva, Cintia C; Grisolia, Cesar K
2018-03-15
Wildfire is very common in Brazilian savannas, and its effects on water, soil and aquatic/soil organisms are poorly understood. In this study, we observed the effects of fire, especially of ashes, on surface soil and subsurface water in a typical Brazilian savanna (Cerrado sensu strictu) for one year. Soil analyses (pH, organic matter content, potential acidity, K, Ca, Mg and P) and subsurface water analyses (NO 3- , PO 4 3- Mg 2+ , Ca 2+ and K + ) were assessed. We evaluated the ecotoxicological effects of ashes on three different endpoints and species, in fish Danio rerio (embryonic development), aquatic snail Biomphalaria glabrata (reproduction) and a soil species Enchytraeus sp. (reproduction). We found a higher amount of exchangeable cations and organic matter content in short-term fire effects on soil, but the higher availability of nutrients did not affect the soil pH in field plots. The effects of ashes on soil and subsurface water did not persist for one-year post-fire, except for organic matter content in burned areas. No toxic effects were observed on hatching success and incidences of developmental abnormalities in D. rerio embryos. However, ash input had adverse effects on reproduction in snails and enchytraeids. We reported a statistically significant decrease in snail eggs exposed to the 50g.L -1 and 100g.L -1 of ashes after four weeks (p<0.05, Dunnett's test and Tukey test). Enchytraeus sp. reproduction was negatively influenced by the natural soil, which presents high acidity, and also when exposed directly to the ashes from burned area, suggesting that pH and other ash compounds may limit the growth of enchytraeids. More studies in burned areas are strongly encouraged, addressing the potential important routes of exposure to ashes in order to understand the impact of intense fires on soil and aquatic biota in tropical savannas. Copyright © 2017 Elsevier B.V. All rights reserved.
Impact of Wildfire on Solute Release in Forested Catchments, Jemez River, New Mexico, USA
NASA Astrophysics Data System (ADS)
Sanchez, R. A.; Meixner, T.; McIntosh, J. C.; Chorover, J.
2017-12-01
Wildfires represent a large disturbance to the hydrology and biogeochemistry of forested catchments. The number, size and severity of wildfires have significantly increased in the western United States since 1990. Nutrients and other elements (e.g. Ca) that were taken up and stored by biomass are released from burned vegetation during forest fires and transported downgradient via overland flow, shallow subsurface flow, and/or deep groundwater flow. Ash accumulations on hillslopes may also store particulate carbon and contain elevated concentrations of elements that maybe leached into surface and ground water over extended periods of time. In 2013, the Thompson Ridge wildfire burned headwater catchments in the Jemez River Basin Critical Zone Observatory (JRB-CZO) within the Valles Caldera National Preserve, New Mexico USA. The burn severity and area impacted were different in the three headwater catchments. This study investigated the impact of the wildfire on surface water quality, including how the fire-induced impacts evolved with time, and how biogeochemical processes controlled post-fire solute concentrations in the surface water. Comparison of pre- and post-fire surface water solute chemistry shows increases in major cations and anions following fire. Increases in nitrate and sulfate concentrations in streams after the wildfire were likely from leaching of burned biomass. The elevated NO3- and SO42- concentrations persisted for over two years, and were even higher during spring snowmelt. Meanwhile, base cation concentrations increased immediately, within a few weeks after the fire, likely related to leaching from combusted organic matter; and, over a period of approximately two months, base cation concentrations returned to pre-fire levels. Trace element behavior was also altered by fire. For example, while pre-fire aluminum concentrations in stream flow increased significantly during the wet seasons (snowmelt and monsoons), the post-fire observations do not show significant changes with increase in discharge.
2017-06-21
military facilities and firing ranges, may pose a risk to the environment10 and humans ’ health .13 As such, it may require a remediation plan for the...fire ranges. Nitroaromatic and nitramine compounds such as explosives are carcinogenic and mutagenic so they pose threat to human health and the...detonations. It is crucial to understand their fate and transport in subsurface environments as they can pose a significant hazard to humans and
Coal Field Fire Fighting - Practiced methods, strategies and tactics
NASA Astrophysics Data System (ADS)
Wündrich, T.; Korten, A. A.; Barth, U. H.
2009-04-01
Subsurface coal fires destroy millions of tons of coal each year, have an immense impact to the ecological surrounding and threaten further coal reservoirs. Due to enormous dimensions a coal seam fire can develop, high operational expenses are needed. As part of the Sino-German coal fire research initiative "Innovative technologies for exploration, extinction and monitoring of coal fires in Northern China" the research team of University of Wuppertal (BUW) focuses on fire extinction strategies and tactics as well as aspects of environmental and health safety. Besides the choice and the correct application of different extinction techniques further factors are essential for the successful extinction. Appropriate tactics, well trained and protected personnel and the choice of the best fitting extinguishing agents are necessary for the successful extinction of a coal seam fire. The chosen strategy for an extinction campaign is generally determined by urgency and importance. It may depend on national objectives and concepts of coal conservation, on environmental protection (e.g. commitment to green house gases (GHG) reductions), national funding and resources for fire fighting (e.g. personnel, infrastructure, vehicles, water pipelines); and computer-aided models and simulations of coal fire development from self ignition to extinction. In order to devise an optimal fire fighting strategy, "aims of protection" have to be defined in a first step. These may be: - directly affected coal seams; - neighboring seams and coalfields; - GHG emissions into the atmosphere; - Returns on investments (costs of fire fighting compared to value of saved coal). In a further step, it is imperative to decide whether the budget shall define the results, or the results define the budget; i.e. whether there are fixed objectives for the mission that will dictate the overall budget, or whether the limited resources available shall set the scope within which the best possible results shall be achieved. For an effective and efficient fire fighting optimal tactics are requiered and can be divided into four fundamental tactics to control fire hazards: - Defense (digging away the coal, so that the coal can not begin to burn; or forming a barrier, so that the fire can not reach the not burning coal), - Rescue the coal (coal mining of a not burning seam), - Attack (active and direct cooling of burning seam), - Retreat (only monitoring till self-extinction of a burning seam). The last one is used when a fire exceeds the organizational and/or technical scope of a mission. In other words, "to control a coal fire" does not automatically and in all situations mean "to extinguish a coal fire". Best-practice tactics or a combination of them can be selected for control of a particular coal fire. For the extinguishing works different extinguishing agents are available. They can be applied by different application techniques and varying distinctive operating expenses. One application method may be the drilling of boreholes from the surface or covering the surface with low permeability soils. The mainly used extinction agents for coal field fire are as followed: Water (with or without additives), Slurry, Foaming mud/slurry, Inert gases, Dry chemicals and materials and Cryogenic agents. Because of its tremendous dimension and its complexity the worldwide challenge of coal fires is absolutely unique - it can only be solved with functional application methods, best fitting strategies and tactics, organisation and research as well as the dedication of the involved fire fighters, who work under extreme individual risks on the burning coal fields.
Geoelectrical image of the subsurface for CO2 geological storage in the Changhua site, Taiwan
NASA Astrophysics Data System (ADS)
Chiang, C. W.; Chiao, C. H.; Yang, M. W.; Yu, C. W.; Yang, C. H.; Chen, C. C.
2016-12-01
Global warming has recently become an important worldwide issue. Reduction of carbon dioxide (CO2) emission is recommended by Intergovernmental Panel on Climate Change, which geological storage is one of possible way to reduce the CO2 issue. The Taichung Power Plant is a coal-fired power plant operated by the Taiwan Power Company in Taichung, Taiwan, which is the largest coal-fired power station in the world. The power plant emits approximately 40 million tons annually which is also the world's largest CO2 emitter. Geophysical techniques are presented as the most useful tool to characterize the reservoir. The electrical resistivity tool was carried out applying audio-magnetotelluric (AMT) method, which could provide the depth resolution for evaluating the subsurface. A first survey of 20 AMT soundings was acquired to study the viability of the method to characterize the subsurface. Stations were deployed at approximately 500 m intervals and the data were recorded in the frequency range of 104-100 Hz. The dimensionality analysis proved the validity of the 1-D or 2-D assumption. The visualized model shows a layered electrical resistivity structure from shallow to depth of 3000 m. The preliminary result corresponds to seismic reflection and geological investigations that suggests a simple geological structure without complex geological processes in the area. It could be a suitable site for geological storage.
Application of Paste Backfill in Underground Coal Fires
NASA Astrophysics Data System (ADS)
Masniyom, M.; Drebenstedt, C.
2009-04-01
Coal fires are known from different coalfields worldwide. China, India, USA, Australia, Indonesia and South Africa are the main countries affected by coal fires. The fires is thermally intensive and cause numerous sinkholes, large-scale subsidence, air pollution, global warming, loss of mining productivity and increasing safety risk. The Wuda Inner Mongolia coalfield has been selected as a possible test area for paste backfill. The traditional methods, executed by fire fighting teams, by covering the coalfire areas with soil, blasting burning coal outcrops and injecting water in the subsurface fire pockets are continuously improved and extended. Initiatives to introduce modern techniques, such as backfill placement at fracture and borehole, to cool down the burning coal and cut off the air supply. This study is to investigate backfill materials and techniques suited for underground coal fires. Laboratory tests were carried out on physical, chemical and mechanical properties of different backfill materials and mixtures thereof. Special attention was paid to materials generated as by-products and other cheaply available materials e.g. fly ash from power plants. There is a good chance that one of the different material mixtures investigated can be used as a technically and economically viable backfill for underground coal fires.
Geophysical survey for groundwater potential investigation in peat land area, Riau, Indonesia
NASA Astrophysics Data System (ADS)
Islami, N.; Irianti, M.; Azhar; Nor, M.; Fakhrudin
2018-04-01
Tropical forests, especially peat lands, are particularly vulnerable to forest fires. Fires are the most common disasters in peat lands in the dry season, especially in Riau Province, Indonesia. In the process of extinguishing the peat fire, several substantial problems arise to stop peat fires during this period. This study aims to determine the possibility of using ground water as a source of water to anticipate the early mitigation of peat land fires disaster. The geoelectrical resistivity surveys were used to predict the subsurface geological data including peat thickness and depth of aquifers. The geometry of peat lands was determined using geostatistics based on geoelectrical resistivity interpretation data. Peat Land thickness varies up to 4 m in the north and is thinner to the south. A shallower and deeper aquifer is available at a depth of 13 m to 18 m and 70 m to 90 m respectively. In general, the potential of groundwater in the shallow aquifer is predicted to be sufficient for peat land watering anytime.
Hillslope hydrology research at Caspar Creek
Elizabeth T. Keppeler; Peter H. Cafferata
1991-01-01
As part of the ongoing Caspar Creek Watershed Study on Jackson Demonstration State Forest, researchers from the US Forest Service and the California Department of Forestry and Fire Protection are investigating subsurface drainage in the headwaters of the basin. In order to predict how land use practices will impact stream systems, and hence habitats for aquatic...
Modeling physical and biogeochemical controls over carbon accumulation in a boreal forest soil
Carrasco, J.J.; Neff, J.C.; Harden, J.W.
2006-01-01
Boreal soils are important to the global C cycle owing to large C stocks, repeated disturbance from fire, and the potential for permafrost thaw to expose previously stable, buried C. To evaluate the primary mechanisms responsible for both short- and long-term C accumulation in boreal soils, we developed a multi-isotope (12,14C) Soil C model with dynamic soil layers that develop through time as soil organic matter burns and reaccumulates. We then evaluated the mechanisms that control organic matter turnover in boreal regions including carbon input rates, substrate recalcitrance, soil moisture and temperature, and the presence of historical permafrost to assess the importance of these factors in boreal C accumulation. Results indicate that total C accumulation is controlled by the rate of carbon input, decomposition rates, and the presence of historical permafrost. However, unlike more temperate ecosystems, one of the key mechanisms involved in C preservation in boreal soils examined here is the cooling of subsurface soil layers as soil depth increases rather than increasing recalcitrance in subsurface soils. The propagation of the 14C bomb spike into soils also illustrates the importance of historical permafrost and twentieth century warming in contemporary boreal soil respiration fluxes. Both 14C and total C simulation data also strongly suggest that boreal SOM need not be recalcitrant to accumulate; the strong role of soil temperature controls on boreal C accumulation at our modeling test site in Manitoba, Canada, indicates that carbon in the deep organic soil horizons is probably relatively labile and thus subject to perturbations that result from changing climatic conditions in the future. Copyright 2006 by the American Geophysical Union.
STRUCTURAL HETEROGENEITIES AND PALEO FLUID FLOW IN AN ANALOG SANDSTONE RESERVOIR 2001-2004
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pollard, David; Aydin, Atilla
2005-02-22
Fractures and faults are brittle structural heterogeneities that can act both as conduits and barriers with respect to fluid flow in rock. This range in the hydraulic effects of fractures and faults greatly complicates the challenges faced by geoscientists working on important problems: from groundwater aquifer and hydrocarbon reservoir management, to subsurface contaminant fate and transport, to underground nuclear waste isolation, to the subsurface sequestration of CO2 produced during fossil-fuel combustion. The research performed under DOE grant DE-FG03-94ER14462 aimed to address these challenges by laying a solid foundation, based on detailed geological mapping, laboratory experiments, and physical process modeling, onmore » which to build our interpretive and predictive capabilities regarding the structure, patterns, and fluid flow properties of fractures and faults in sandstone reservoirs. The material in this final technical report focuses on the period of the investigation from July 1, 2001 to October 31, 2004. The Aztec Sandstone at the Valley of Fire, Nevada, provides an unusually rich natural laboratory in which exposures of joints, shear deformation bands, compaction bands and faults at scales ranging from centimeters to kilometers can be studied in an analog for sandstone aquifers and reservoirs. The suite of structures there has been documented and studied in detail using a combination of low-altitude aerial photography, outcrop-scale mapping and advanced computational analysis. In addition, chemical alteration patterns indicative of multiple paleo fluid flow events have been mapped at outcrop, local and regional scales. The Valley of Fire region has experienced multiple episodes of fluid flow and this is readily evident in the vibrant patterns of chemical alteration from which the Valley of Fire derives its name. We have successfully integrated detailed field and petrographic observation and analysis, process-based mechanical modeling, and numerical simulation of fluid flow to study a typical sandstone aquifer/reservoir at a variety of scales. We have produced many tools and insights which can be applied to active subsurface flow systems and practical problems of pressing global importance.« less
Soil water balance as affected by throughfall in gorse ( Ulex europaeus, L.) shrubland after burning
NASA Astrophysics Data System (ADS)
Soto, Benedicto; Diaz-Fierros, Francisco
1997-08-01
The role of fire in the hydrological behaviour of gorse shrub is studied from the point of view of its effects on vegetation cover and throughfall. In the first year after fire, throughfall represents about 88% of gross rainfall, whereas in unburnt areas it is 58%. Four years after fire, the throughfall coefficients are similar in burnt and unburnt plots (about 6096). The throughfall is not linearly related to vegetation cover because an increase in cover does not involve a proportional reduction in throughfall. The throughfall predicted by the two-parameter exponential model of Calder (1986, J. Hydrol., 88: 201-211) provides a good fit with the observed throughfall and the y value of the model reflects the evolution of throughfall rate. The soil moisture distribution is modified by fire owing to the increase of evaporation in the surface soil and the decrease of transpiration from deep soil layers. Nevertheless, the use of the old root system by sprouting vegetation leads to a soil water profile in which 20 months after the fire the soil water is similar in burnt and unburnt areas. Overall, soil moisture is higher in burnt plots than in unburnt plots. Surface runoff increases after a fire but does not entirely account for the increase in throughfall. Therefore the removal of vegetation cover in gorse scrub by fire mainly affects the subsurface water flows.
Weber, Andrea K; Barber, Larry B; LeBlanc, Denis R; Sunderland, Elsie M; Vecitis, Chad D
2017-04-18
Growing evidence that certain poly- and perfluoroalkyl substances (PFASs) are associated with negative human health effects prompted the U.S. Environmental Protection Agency to issue lifetime drinking water health advisories for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in 2016. Given that groundwater is a major source of drinking water, the main objective of this work was to investigate geochemical and hydrological processes governing the subsurface transport of PFASs at a former fire training area (FTA) on Cape Cod, Massachusetts, where PFAS-containing aqueous film-forming foams were used historically. A total of 148 groundwater samples and 4 sediment cores were collected along a 1200-m-long downgradient transect originating near the FTA and analyzed for PFAS content. The results indicate that unsaturated zones at the FTA and at hydraulically downgradient former domestic wastewater effluent infiltration beds both act as continuous PFAS sources to the groundwater despite 18 and 20 years of inactivity, respectively. Historically different PFAS sources are evident from contrasting PFAS composition near the water table below the FTA and wastewater-infiltration beds. Results from total oxidizable precursor assays conducted using groundwater samples collected throughout the plume suggest that some perfluoroalkyl acid precursors at this site are transporting with perfluoroalkyl acids.
Weber, Andrea K.; Barber, Larry B.; LeBlanc, Denis R.; Sunderland, Elsie M.; Vecitis, Chad D.
2017-01-01
Growing evidence that certain poly- and perfluoroalkyl substances (PFASs) are associated with negative human health effects prompted the U.S. Environmental Protection Agency to issue lifetime drinking water health advisories for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in 2016. Given that groundwater is a major source of drinking water, the main objective of this work was to investigate geochemical and hydrological processes governing the subsurface transport of PFASs at a former fire training area (FTA) on Cape Cod, Massachusetts, where PFAS-containing aqueous film-forming foams were used historically. A total of 148 groundwater samples and 4 sediment cores were collected along a 1200-m-long downgradient transect originating near the FTA and analyzed for PFAS content. The results indicate that unsaturated zones at the FTA and at hydraulically downgradient former domestic wastewater effluent infiltration beds both act as continuous PFAS sources to the groundwater despite 18 and 20 years of inactivity, respectively. Historically different PFAS sources are evident from contrasting PFAS composition near the water table below the FTA and wastewater-infiltration beds. Results from total oxidizable precursor assays conducted using groundwater samples collected throughout the plume suggest that some perfluoroalkyl acid precursors at this site are transporting with perfluoroalkyl acids.
Influence of firing time and framework thickness on veneered Y-TZP discs curvature.
Jakubowicz-Kohen, Boris D; Sadoun, Michaël J; Douillard, Thierry; Mainjot, Amélie K
2014-02-01
The objective of the present work was to study the curvature of very thinly, veneered Y-TZP discs of different framework thicknesses submitted to different firing times. Fifteen 20-mm-wide Y-TZP discs were produced in three different thicknesses: 0.75, 1, 1.5mm. One disc from each group was left unveneered while the others were layered with a 0.1mm veneering ceramic layer. All discs underwent five firing cycles for a total cumulative firing time of 30 min, 1, 2, 5 and 10h at 900°C. The curvature profile was measured using a profilometer after the veneering process and after each firing cycle respectively. A fitted curve was then used to estimate the, curvature radius. The coefficient of thermal expansion (CTE) measurements were taken on veneering, ceramic and Y-TZP beam samples that underwent the same firing schedule. Those data were used to calculate the curvature generated by CTE variations over firing time. All bilayered samples exhibited a curvature that increased over firing time inversely to framework thickness. However non-veneered samples did not exhibit any curvature modification. The results of the present study reveal that even a very thin veneer layer (0.1mm) can induce a significant curvature of Y-TZP discs. The dilatometric results showed that Tg and CTE, variations are not sufficient to explain this curvature. A chemical-induced zirconia volume, augmentation located at the framework sub-surface near the interface could explain the sample, curvature and its increase with firing time. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
A laboratory rainfall simulator to study the soil erosion and runoff water
NASA Astrophysics Data System (ADS)
Cancelo González, Javier; Rial, M. E.; Díaz-Fierros, Francisco
2010-05-01
The soil erosion and the runoff water composition in some areas affected by forest fires or submitted to intensive agriculture are an important factor to keep an account, particularly in sensitive areas like estuary and rias that have a high importance in the socioeconomic development of some regions. An understanding of runoff production indicates the processes by which pollutants reach streams and also indicates the management techniques that might be uses to minimize the discharge of these materials into surface waters. One of the most methodology implemented in the soil erosion studies is a rainfall simulation. This method can reproduce the natural soil degradation processes in field or laboratory experiences. With the aim of improve the rainfall-runoff generation, a laboratory rainfall simulator which incorporates a fan-like intermittent water jet system for rainfall generation were modified. The major change made to the rainfall simulator consist in a system to coupling stainless steel boxes, whose dimensions are 12 x 20 x 45 centimeters, and it allows to place soil samples under the rainfall simulator. Previously these boxes were used to take soil samples in field with more of 20 centimeters of depth, causing the minimum disturbance in their properties and structure. These new implementations in the rainfall simulator also allow collect water samples of runoff in two ways: firstly, the rain water that constituted the overland flow or direct runoff and besides the rain water seeps into the soil by the process of infiltration and contributed to the subsurface runoff. Among main the variables controlled in the rainfall simulations were the soil slope and the intensity and duration of rainfall. With the aim of test the prototype, six soil samples were collected in the same sampling point and subjected to rainfall simulations in laboratory with the same intensity and duration. Two samples will constitute the control test, and they were fully undisturbed, and four samples were subjected to controlled burnings with different fire severity: two samples burnt to 250°C and the other two samples burnt to 450°C. Preliminary laboratory data of soil erosion and surface and subsurface runoff were obtained. The water parameters analysed were: pH, electrical conductivity, temperature (in the moment of sampling) and suspended sediments, ammonium, nitrates, total nitrogen (Kjeldahl method), within 24 hours after sampling.
Test Plan to Assess Fire Effects on the Function of an Engineered Surface Barrier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, Anderson L.; Berlin, Gregory T.; Cammann, Jerry W.
2008-09-29
Wildfire is a frequent perturbation in shrub steppe ecosystems, altering the flora, fauna, atmosphere, and soil of these systems. Research on the fire effects has focused mostly on natural ecosystems with essentially no attention on engineered systems like surface barriers. The scope of the project is to use a simulated wildfire to induce changes in an engineered surface barrier and document the effects on barrier performance. The main objective is to quantify the effects of burning and the resulting post-fire conditions on alterations in soil physical properties; hydrologic response, particularly the water balance; geochemical properties; and biological properties. A secondarymore » objective is to use the lessons learned to maximize fire protection in the design of long-term monitoring systems based on electronic sensors. A simulated wildfire will be initiated, controlled and monitored at the 200-BP-1 barrier in collaboration with the Hanford Fire Department during the fall of 2008. The north half of the barrier will be divided into nine 12 x 12 m plots, each of which will be randomly assigned a fuel load of 2 kg m-2 or 4 kg m-2. Each plot will be ignited around the perimeter and flames allowed to carry to the centre. Any remaining unburned vegetation will be manually burned off using a drip torch. Progress of the fire and its effects will be monitored using point measurements of thermal, hydrologic, and biotic variables. Three measures of fire intensity will be used to characterize fire behavior: (1) flame height, (2) the maximum temperature at three vertical profile levels, and (3) total duration of elevated temperature at these levels. Pre-burn plant information, including species diversity, plant height, and canopy diameter will be measured on shrubs from the plots to be burned and from control plots at the McGee ranch. General assessments of shrub survival, recovery, and recruitment will be made after the fire. Near-surface soil samples will be collected pre- and post-burn to determine changes in the gravel content of the surface layer so as to quantify inflationary or deflationary responses to fire and to reveal the ability of the surface to resist post-fire erosive stresses. Measures of bulk density, water repellency, water retention, and hydraulic conductivity will be used to characterize changes in infiltration rates and water storage capacity following the fire. Samples will also be analyzed to quantify geochemical changes including changes in soil pH, cation exchange capacity, specific surface area, and the concentration of macro nutrients (e.g. N, P, K) and other elements such as Na, Mg, Ca, that are critical to the post-fire recovery revegetation. Soil CO2 emissions will be measured monthly for one year following the burn to document post-fire stimulation of carbon turnover and soil biogenic emissions. Surface and subsurface temperature measurements at and near monitoring installations will be used to document fire effects on electronic equipment. The results of this study will be used to bridge the gaps in knowledge on the effects of fire on engineered ecosystems (e.g. surface barriers), particularly the hydrologic and biotic characteristics that govern the water and energy balance. These results will also support the development of practical fire management techniques for barriers that are compatible with wildfire suppression strategies. Furthermore, lessons learned will be use to develop installation strategies needed to protect electronic monitoring equipment from the intense heat of fire and the potential damaging effects of smoke and fire extinguishing agents. Such information is needed to better understand long-term barrier performance under extreme conditions, especially if site maintenance and operational funding is lost for activities such as barrier revegetation.« less
Forde, Arnell S.; Bernier, Julie C.; Miselis, Jennifer L.
2018-02-22
Researchers from the U.S. Geological Survey (USGS) conducted a long-term coastal morphologic-change study at Fire Island, New York, prior to and after Hurricane Sandy impacted the area in October 2012. The Fire Island Coastal Change project objectives include understanding the morphologic evolution of the barrier island system on a variety of time scales (months to centuries) and resolving storm-related impacts, post-storm beach response, and recovery. In April 2016, scientists from the USGS St. Petersburg Coastal and Marine Science Center conducted geophysical and sediment sampling surveys on Fire Island to characterize and quantify spatial variability in the subaerial geology with the goal of subsequently integrating onshore geology with other surf zone and nearshore datasets. This report, along with the associated USGS data release, serves as an archive of ground penetrating radar (GPR) and post-processed differential global positioning system (DGPS) data collected from beach and back-barrier environments on Fire Island, April 6–13, 2016 (USGS Field Activity Number 2016-322-FA). Data products, including unprocessed GPR trace data, processed DGPS data, elevation-corrected subsurface profile images, geographic information system files, and accompanying Federal Geographic Data Committee metadata are available for download.
Forwardly-placed firearm fire control assembly
Frickey, Steven J.
2001-12-22
A firearm fire control assembly for disposition in a forwardly placed support-hand operative relationship within a firearm having a combination of a firing pin and a firearm hammer adapted to engage and fire a cartridge, a sear assembly to alternately engage and disengage the combination of the firearm hammer and firing pin, and a trigger assembly including a movable trigger mechanism that is operable to engage the sear assembly to cause the firearm hammer firing pin combination to fire the firearm, a fire control assembly including a fire control depression member and a fire control rod operably connected to the depression member, and being positioned in a forward disposition disposed within a forestock of the firearm, and the depression member adapted to be operably engaged and depressed by the user's conventional forwardly placed support hand to maneuver the fire control rod to provide firing control of the firing of the firearm.
Fire Control Agent Effectiveness for Hazardous Chemical Fires: Carbon Disulfide.
1981-01-01
Fires..................................... 46 12. AFFF Fire Control Data for Carbon Disulfide Fires............................. 47 13. Extinguishment...Disulfide and Hexane Fires ....... 67 22. Comparison of AFFF Fire Control Times for Carbon Disulfide and Hexane Fires ................... 68 23. Comparison of...Data .............. 27 2. Summary of Fluoroprotein Foam Fire Test Data ....... 28 3. Summary of AFFF Fire Test Data ..................... 29 4. Summary
Environmenal analysis of the Bayo Canyon (TA-10) Site, Los Alamos, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferenbaugh, R.W.; Buhl, T.E.; Stoker, A.K.
1982-05-01
The radiological survey of the old TA-10 site in Bayo Canyon found low levels of surface contamination in the vicinity of the firing sites and subsurface contamination in the old waste disposal area. The three alternatives proposed for the site are: (1) to take no action; (2) to restrict usage of the area of subsurface contamination to activities that cause no subsurface disturbance (minimal action); and (3) to remove the subsurface conamination to levels below the working criteria. Dose calculations indicate that doses from surface contamination for recreational users of the canyon, permanent residents, and construction workers and doses formore » workers involved in excavation of contaminated soil under the clean up alternative are only small percentages of applicable guidelines. No environmental impacts are associated with either the no-action or minimal action alternatives. The impact associated with the cleanup alternative is small, especially considering that the area already has been affected by the original TA-10 decommissioning action, but nevertheless, the preferred alternative is the minimal action alternative, where 0.6 hectare of land is restricted to surface activities. This leaves the rest of the canyon available for development with up to 400 homes. The restricted area can be used for a park, tennis courts, etc., and the /sup 90/Sr activity will decay to levels permitting unrestricted usage in about 160 y.« less
Electronic firing systems and methods for firing a device
Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID
2012-04-24
An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.
Soil Carbon Dioxide Production and Surface Fluxes: Subsurface Physical Controls
NASA Astrophysics Data System (ADS)
Risk, D.; Kellman, L.; Beltrami, H.
Soil respiration is a critical determinant of landscape carbon balance. Variations in soil temperature and moisture patterns are important physical processes controlling soil respiration which need to be better understood. Relationships between soil respi- ration and physical controls are typically addressed using only surface flux data but other methods also exist which permit more rigorous interpretation of soil respira- tion processes. Here we use a combination of subsurface CO_{2} concentrations, surface CO_{2} fluxes and detailed physical monitoring of the subsurface envi- ronment to examine physical controls on soil CO_{2} production at four climate observatories in Eastern Canada. Results indicate that subsurface CO_{2} produc- tion is more strongly correlated to the subsurface thermal environment than the surface CO_{2} flux. Soil moisture was also found to have an important influence on sub- surface CO_{2} production, particularly in relation to the soil moisture - soil profile diffusivity relationship. Non-diffusive profile CO_{2} transport appears to be im- portant at these sites, resulting in a de-coupling of summertime surface fluxes from subsurface processes and violating assumptions that surface CO_{2} emissions are the result solely of diffusion. These results have implications for the study of soil respiration across a broad range of terrestrial environments.
Recent Advances in Subsurface Imaging and Monitoring with Active Sources in China
NASA Astrophysics Data System (ADS)
Wang, B.; Chen, Y.; Wang, W.; Yang, W.
2017-12-01
Imaging high-resolution crustal structures and monitoring their temporal changes with active sources is essential to our understanding of regional tectonics and seismic hazards. In the past decades, great efforts has been made in China to looking for an ideal artificial seismic source to study continental crustal structures. After a mountain of field experiments, we developed permanent and portable seismic airgun sources for inland seismotectonic studies. Here we introduce several applications of using airgun source to imaging local crustal structures and monitoring velocity changes associated with natural and anthropogenic loadings. During Oct. 10th-20th, 2015, we carried out a crustal structure exploration experiment by firing portable airgun source along the Yangtze River in Anhui Province of eastern China. About 5000 shots were fired along 300km long section of the river. More than 2000 portable short period seismometers or geophones were deployed during the experiment. About 3000 of 5000 shots were fired at 20 fixed sites roughly evenly distributed along the river, and the rest shots were fired in the walkway. Seismic signal radiated by airgun source can be tracked to 350km. 2D/3D near surface and crustal velocity structure along the Yangtze River and adjacent region were inverted from airgun seismic records. Inverted velocity show well consistence with previous images and geological structure. The high resolution structural image provides a better understanding on regional geologic features and distribution of mineral resources. In the past five years, three Fixed Aigun Signal Transmitting Stations (FASTS) were built in western China. Those FASTS generate seismic signals with high repeatability, which can be tracked to the distance 1300 km. The highly reproducible signals are used to monitor the subtle subsurface changes. Observed diurnal and semi-diurnal velocity changes 10-4 are supposed to be results of barometrical and tidal loading. Suspicious velocity changes prior to several moderate earthquakes are detected around. Seismic velocity measured around the Hutubi underground gas storage show clear correlation with the gas pressure. Those results shed some light on the short term evolution of the shallow to low crust, which may boost our understanding the mechanism of local seismic hazards.
Production and efficiency of large wildland fire suppression effort: A stochastic frontier analysis.
Katuwal, Hari; Calkin, David E; Hand, Michael S
2016-01-15
This study examines the production and efficiency of wildland fire suppression effort. We estimate the effectiveness of suppression resource inputs to produce controlled fire lines that contain large wildland fires using stochastic frontier analysis. Determinants of inefficiency are identified and the effects of these determinants on the daily production of controlled fire line are examined. Results indicate that the use of bulldozers and fire engines increase the production of controlled fire line, while firefighter crews do not tend to contribute to controlled fire line production. Production of controlled fire line is more efficient if it occurs along natural or built breaks, such as rivers and roads, and within areas previously burned by wildfires. However, results also indicate that productivity and efficiency of the controlled fire line are sensitive to weather, landscape and fire characteristics. Copyright © 2015 Elsevier Ltd. All rights reserved.
Method for formation of subsurface barriers using viscous colloids
Apps, J.A.; Persoff, P.; Moridis, G.; Pruess, K.
1998-11-17
A method is described for formation of subsurface barriers using viscous liquids where a viscous liquid solidifies at a controlled rate after injection into soil and forms impermeable isolation of the material enclosed within the subsurface barriers. The viscous liquid is selected from the group consisting of polybutenes, polysiloxanes, colloidal silica and modified colloidal silica of which solidification is controlled by gelling, cooling or cross-linking. Solidification timing is controlled by dilution, addition of brines, coating with alumina, stabilization with various agents and by temperature. 17 figs.
IMPACT OF REDOX DISEQUILIBRIA ON CONTAMINANT TRANSPORT AND REMEDIATION IN SUBSURFACE SYSTEMS
Partitioning to mineral surfaces exerts significant control on inorganic contaminant transport in subsurface systems. Remedial technologies for in-situ treatment of subsurface contamination are frequently designed to optimize the efficiency of contaminant partitioning to solid s...
An Autonomous Cryobot Synthetic Aperture Radar for Subsurface Exploration of Europa
NASA Astrophysics Data System (ADS)
Pradhan, O.; Gasiewski, A. J.
2015-12-01
We present the design and field testing of a forward-looking end-fire synthetic aperture radar (SAR) for the 'Very deep Autonomous Laser-powered Kilowatt-class Yo-yoing Robotic Ice Explorer' (VALKYRIE) ice-penetrating cryobot. This design demonstrates critical technologies that will support an eventual landing and ice penetrating mission to Jupiter's icy moon, Europa. Results proving the feasibility of an end-fire SAR system for vehicle guidance and obstacle avoidance in a sub-surface ice environment will be presented. Data collected by the SAR will also be used for constructing sub-surface images of the glacier which can be used for: (i) mapping of englacial features such as crevasses, moulins, and embedded liquid water and (ii) ice-depth and glacier bed analysis to construct digital elevation models (DEM) that can help in the selection of crybot trajectories and future drill sites for extracting long-term climate records. The project consists of three parts, (i) design of an array of four conformal cavity-backed log-periodic folded slot dipole array (LPFSA) antennas that form agile radiating elements, (ii) design of a radar system that includes RF signal generation, 4x4 transmit-receive antenna switching and isolation and digital SAR data processing and (iii) field testing of the SAR in melt holes. The antennas have been designed, fabricated, and lab tested at the Center for Environmental Technology (CET) at CU-Boulder. The radar system was also designed and integrated at CET utilizing rugged RF components and FPGA based digital processing. Field testing was performed in conjunction with VALKYRIE tests by Stone Aerospace in June, 2015 on Matanuska Glacier, Alaska. The antennas are designed to operate inside ice while being immersed in a thin layer of surrounding low-conductivity melt water. Small holes in the corners of the cavities allow flooding of these cavities with the same melt-water thus allowing for quarter-wavelength cavity-backed reflection. Testing of the antenna array was first carried out by characterizing their operation inside a large ice block at the Stone Aerospace facility in Austin, TX. The complete radar system was then tested on the Matanuska glacier in Alaska, which is an effective Earth analog to Europan sub-surface exploration.
Lamba, Jasmeet; Srivastava, Puneet; Way, Thomas R; Sen, Sumit; Wood, C Wesley; Yoo, Kyung H
2013-09-01
Subsurface band application of poultry litter has been shown to reduce the transport of nutrients from fields in surface runoff compared with conventional surface broadcast application. Little research has been conducted to determine the effects of surface broadcast application and subsurface banding of litter on nutrients in leachate. Therefore, a field experiment was conducted to determine the effects of subsurface band application and surface broadcast application of poultry litter on nutrient losses in leachate. Zero-tension pan and passive capillary fiberglass wick lysimeters were installed in situ 50 cm beneath the soil surface of an established tall fescue ( Schreb.) pasture on a sandy loam soil. The treatments were surface broadcast and subsurface-banded poultry litter at 5 Mg ha and an unfertilized control. Results of the rainfall simulations showed that the concentrations of PO-P and total phosphorus (TP) in leachate were reduced by 96 and 37%, respectively, in subsurface-banded litter treatment compared with the surface-applied litter treatment. There was no significant difference in PO-P concentration between control and subsurface-banded litter treatment in leachate. The trend in the loading of nutrients in leachate was similar to the trend in concentration. Concentration and loading of the nutrients (TP, PO-P, NH-N, and NO-N) in runoff from the subsurface-banded treatment were significantly less than for the surface-applied treatment and were similar to those from control plots. These results show that, compared with conventional surface broadcast application of litter, subsurface band application of litter can greatly reduce loss of P in surface runoff and leachate. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Need to improve SWMM's subsurface flow routing algorithm for green infrastructure modeling
SWMM can simulate various subsurface flows, including groundwater (GW) release from a subcatchment to a node, percolation out of storage units and low impact development (LID) controls, and rainfall derived inflow and infiltration (RDII) at a node. Originally, the subsurface flow...
46 CFR 78.47-17 - Fire extinguishing system controls.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Fire extinguishing system controls. 78.47-17 Section 78... Markings for Fire and Emergency Equipment, Etc. § 78.47-17 Fire extinguishing system controls. (a) The control cabinets or spaces containing valves or manifolds for the various fire extinguishing systems shall...
46 CFR 78.47-17 - Fire extinguishing system controls.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Fire extinguishing system controls. 78.47-17 Section 78... Markings for Fire and Emergency Equipment, Etc. § 78.47-17 Fire extinguishing system controls. (a) The control cabinets or spaces containing valves or manifolds for the various fire extinguishing systems shall...
Preliminary Guidelines For Using Suppression Fires to Control Wildfires in the Southeast
Robert W. Cooper
1969-01-01
Suppression firing is defied as the application of fire to speed or strengthen control action on free-burning wildfires. The key to successful suppression firing is availability of personnel knowledgeable in specific application plus an adequate supply of manpower and equipment to contain the set fire. Preliminary guidelines for the use of this fire-control tool are...
Identification and characterization of natural pipe systems in forested tropical soils
NASA Astrophysics Data System (ADS)
Bovi, Renata Cristina; Moreira, Cesar Augusto; Stucchi Boschi, Raquel; Cooper, Miguel
2017-04-01
Erosive processes on soil surface have been well studied and comprehended by several researchers, however little is known about subsurface erosive processes (piping). Piping is a type of subsurface erosion caused by water flowing in the subsurface and is still considered one of the most difficult erosive processes to be studied. Several processes have been considered as resposible for subsurface erosion and their interaction is complex and difficult to be studied separately. Surface investigations on their own may underestimate the erosion processes, due to the possible occurrence of subsurface processes that are not yet exposed on the surface. The network of subsurface processes should also be understood to better control erosion. Conservation practices that focus on water runoff control may be inefficient if the subsurface flow is not considered. In this study, we aimed to identify and characterize subsurface cavities in the field, as well as understand the network of these cavities, by using geophysical methods (electrical tomography). The study area is situated at the Experimental Station of Tupi, state of São Paulo, Brazil. The soil of the area was classified as Hapludults. The area presents several erosive features, ranging from laminar to permanent gullies and subsurface erosions. The geophysical equipment used was the Terrameter LS resistivity meter, manufactured by ABEM Instruments. The method of electrical tomography was efficient to detect collapsed and non-collapsed pipes. The results presented valuable information to detect areas of risk.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L. N.
This report provides the results of analyses on Tanks 38H and 43H surface and subsurface supernatant liquid samples in support of the Enrichment Control Program (ECP) and the Corrosion Control Program (CCP).
Huang, Ping; Lin, I-I; Chou, Chia; Huang, Rong-Hui
2015-05-18
Tropical cyclones (TCs) are hazardous natural disasters. Because TC intensification is significantly controlled by atmosphere and ocean environments, changes in these environments may cause changes in TC intensity. Changes in surface and subsurface ocean conditions can both influence a TC's intensification. Regarding global warming, minimal exploration of the subsurface ocean has been undertaken. Here we investigate future subsurface ocean environment changes projected by 22 state-of-the-art climate models and suggest a suppressive effect of subsurface oceans on the intensification of future TCs. Under global warming, the subsurface vertical temperature profile can be sharpened in important TC regions, which may contribute to a stronger ocean coupling (cooling) effect during the intensification of future TCs. Regarding a TC, future subsurface ocean environments may be more suppressive than the existing subsurface ocean environments. This suppressive effect is not spatially uniform and may be weak in certain local areas.
Huang, Ping; Lin, I. -I; Chou, Chia; Huang, Rong-Hui
2015-01-01
Tropical cyclones (TCs) are hazardous natural disasters. Because TC intensification is significantly controlled by atmosphere and ocean environments, changes in these environments may cause changes in TC intensity. Changes in surface and subsurface ocean conditions can both influence a TC's intensification. Regarding global warming, minimal exploration of the subsurface ocean has been undertaken. Here we investigate future subsurface ocean environment changes projected by 22 state-of-the-art climate models and suggest a suppressive effect of subsurface oceans on the intensification of future TCs. Under global warming, the subsurface vertical temperature profile can be sharpened in important TC regions, which may contribute to a stronger ocean coupling (cooling) effect during the intensification of future TCs. Regarding a TC, future subsurface ocean environments may be more suppressive than the existing subsurface ocean environments. This suppressive effect is not spatially uniform and may be weak in certain local areas. PMID:25982028
NASA Astrophysics Data System (ADS)
Nesterova, Natalia; Semenova, Olga; Lebedeva, Luidmila
2015-04-01
Large territories of Siberia and Russian Far East are the subject to frequent forest fires. Often there is no information available about fire impact except its timing, areal distribution and qualitative characteristics of fire severity. Observed changes of hydrological response in burnt watersheds can be considered as indirect evidence of soil and vegetation transformation due to fire impact. In our study we used MODIS Fire products to detect spatial distribution of fires in Transbaikal and Far East regions of Russia in 2000 - 2012 period. Small and middle-size watersheds (with area up to 10000 km2) affected by extensive (burn area not less than 20 %) fires were chosen. We analyzed available hydrological data (measured discharges in watersheds outlets) for chosen basins. In several cases apparent hydrological response to fire was detected. To investigate main factors causing the change of hydrologic regime after fire several scenarios of soil and vegetation transformation were developed for each watershed under consideration. Corresponding sets of hydrological model parameters describing those transformations were elaborated based on data analysis and post-fire landscape changes as derived from a literature review. We implied different factors such as removal of organic layer, albedo changes, intensification of soil thaw (in presence of permafrost and seasonal soil freezing), reduction of infiltration rate and evapotranspiration, increase of upper subsurface flow fraction in summer flood events following the fire and others. We applied Hydrograph model (Russia) to conduct simulation experiments aiming to reveal which landscape changes scenarios were more plausible. The advantages of chosen hydrological model for this study are 1) that it takes into consideration thermal processes in soils which in case of permafrost and seasonal soil freezing presence can play leading role in runoff formation and 2) that observable vegetation and soil properties are used as its parameters allowing minimal resort to calibration. The model can use dynamic set of parameters performing preassigned abrupt and/or gradual changes of landscape characteristics. Interestingly, based on modelling results it can be concluded that depending on dominant landscape different aspects of soil and vegetation cover changes may influence runoff formation in contrasting way. The results of the study will be reported.
Safety in the Chemical Laboratory: Fire Safety and Fire Control in the Chemistry Laboratory.
ERIC Educational Resources Information Center
Wilbraham, A. C.
1979-01-01
Discusses fire safety and fire control in the chemistry laboratory. The combustion process, extinguishing equipment, extinguisher maintenance and location, and fire safety and practices are included. (HM)
Female Fire-Setters: Gender-Associated Psychological and Psychopathological Features.
Alleyne, Emma; Gannon, Theresa A; Mozova, Katarina; Page, Thomas E; Ó Ciardha, Caoilte
2016-01-01
Female fire-setters are reported to commit nearly one-third of deliberately set fires, yet there are limited studies examining the characteristics that distinguish them from suitable comparison groups. The aim of this study is to compare incarcerated female fire-setters with incarcerated male fire-setters and female offender controls on psychopathological and psychological features that could be targeted via therapeutic interventions. We recruited 65 female fire-setters, 128 male fire-setters, and 63 female offenders from the prison estate. Participants completed a battery of validated tools assessing psychiatric traits and psychological characteristics (i.e., inappropriate fire interest, emotion/self-regulation, social competence, self-concept, offense-supportive attitudes, and boredom proneness) highlighted in the existing literature. Major depression and an internal locus of control distinguished female fire-setters from male fire-setters. Alcohol dependence, serious/problematic fire interest, and more effective anger regulation distinguished female fire-setters from the female offender control group. This is the first study to examine differences between female fire-setters, male fire-setters, and female control offenders on both psychopathological features and psychological traits. These findings highlight the gender-specific and offense-specific needs of female fire-setters that clinicians need to consider when implementing programs that ensure client responsivity.
Geophysical investigation of the June 6, 1944 D-Day invasion site at Pointe du Hoc, Normandy, France
NASA Astrophysics Data System (ADS)
Everett, M. E.; Pierce, C. J.; Warden, R. R.; Burt, R. A.
2005-05-01
A near-surface geophysical survey at the D-Day invasion site atop the cliffs at Pointe du Hoc, Normandy, France was carried out using ground-penetrating radar, electromagnetic induction, and magnetic gradiometry equipment. The subsurface targets of investigation are predominantly buried concrete and steel structures and earthworks associated with the German coastal fortifications at this stronpoint of Hitler's Atlantic Wall. The targets are readily detectable embedded within the vadose zone of a weakly magnetic, electrically resistive loess soil cover. The radar and electromagnetic induction responses lend themselves to plan-view imaging of the subsurface, while the magnetics data reveal the presence of buried magnetic bodies in a more subtle fashion. Several intriguing geophysical signatures were discovered, including what may be the buried remains of a railway turntable, ordnance fragments in the bomb craters, a buried steel-reinforced concrete trench, and a linear chain of machine gun firing positins. Geophysical prospecting is shown to be a very powerful tool for historical battlefield characterization.
NASA Astrophysics Data System (ADS)
Condro, A. A.; Pawitan, H.; Risdiyanto, I.
2018-05-01
Peatlands are very vulnerable to widespread fires during dry seasons, due to availability of aboveground fuel biomass on the surface and belowground fuel biomass on the sub-surface. Hence, understanding drought propagation occurring within peat layers is crucial with regards to disaster mitigation activities on peatlands. Using a three dimensionally explicit voxel-based model of peatland hydrology, this study predicted drought propagation time lags into sub-surface peat layers after drought events occurrence on the surface of about 1 month during La-Nina and 2.5 months during El-Nino. The study was carried out on a high-conservation-value area of oil palm plantation in West Kalimantan. Validity of the model was evaluated and its applicability for disaster mitigation was discussed. The animations of simulated voxels are available at: goo.gl/HDRMYN (El-Nino 2015 episode) and goo.gl/g1sXPl (La-Nina 2016 episode). The model is available at: goo.gl/RiuMQz.
H.R. Barnard; C.B. Graham; W.J. van Verseveld; J.R. Brooks; B.J. Bond; J.J. McDonnell
2010-01-01
Mechanistic assessment of how transpiration influences subsurface flow is necessary to advance understanding of catchment hydrology. We conducted a 24-day, steady-state irrigation experiment to quantify the relationships among soil moisture, transpiration and hillslope subsurface flow. Our objectives were to: (1) examine the time lag between maximum transpiration and...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection of flight controls, engine...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
Controlling Subsurface Fractures and Fluid Flow: A Basic Research Agenda
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pyrak-Nolte, Laura J; DePaolo, Donald J.; Pietraß, Tanja
2015-05-22
From beneath the surface of the earth, we currently obtain about 80-percent of the energy our nation consumes each year. In the future we have the potential to generate billions of watts of electrical power from clean, green, geothermal energy sources. Our planet’s subsurface can also serve as a reservoir for storing energy produced from intermittent sources such as wind and solar, and it could provide safe, long-term storage of excess carbon dioxide, energy waste products and other hazardous materials. However, it is impossible to underestimate the complexities of the subsurface world. These complexities challenge our ability to acquire themore » scientific knowledge needed for the efficient and safe exploitation of its resources. To more effectively harness subsurface resources while mitigating the impacts of developing and using these resources, the U.S. Department of Energy established SubTER – the Subsurface Technology and Engineering RD&D Crosscut team. This DOE multi-office team engaged scientists and engineers from the national laboratories to assess and make recommendations for improving energy-related subsurface engineering. The SubTER team produced a plan with the overall objective of “adaptive control of subsurface fractures and fluid flow.”This plan revolved around four core technological pillars—Intelligent Wellbore Systems that sustain the integrity of the wellbore environment; Subsurface Stress and Induced Seismicity programs that guide and optimize sustainable energy strategies while reducing the risks associated with subsurface injections; Permeability Manipulation studies that improve methods of enhancing, impeding and eliminating fluid flow; and New Subsurface Signals that transform our ability to see into and characterize subsurface systems. The SubTER team developed an extensive R&D plan for advancing technologies within these four core pillars and also identified several areas where new technologies would require additional basic research. In response, the Office of Science, through its Office of Basic Energy Science (BES), convened a roundtable consisting of 15 national lab, university and industry geoscience experts to brainstorm basic research areas that underpin the SubTER goals but are currently underrepresented in the BES research portfolio. Held in Germantown, Maryland on May 22, 2015, the round-table participants developed a basic research agenda that is detailed in this report. Highlights include the following: -A grand challenge calling for advanced imaging of stress and geological processes to help understand how stresses and chemical substances are distributed in the subsurface—knowledge that is critical to all aspects of subsurface engineering; -A priority research direction aimed at achieving control of fluid flow through fractured media; -A priority research direction aimed at better understanding how mechanical and geochemical perturbations to subsurface rock systems are coupled through fluid and mineral interactions; -A priority research direction aimed at studying the structure, permeability, reactivity and other properties of nanoporous rocks, like shale, which have become critical energy materials and exhibit important hallmarks of mesoscale materials; -A cross-cutting theme that would accelerate development of advanced computational methods to describe heterogeneous time-dependent geologic systems that could, among other potential benefits, provide new and vastly improved models of hydraulic fracturing and its environmental impacts; -A cross-cutting theme that would lead to the creation of “geo-architected materials” with controlled repeatable heterogeneity and structure that can be tested under a variety of thermal, hydraulic, chemical and mechanical conditions relevant to subsurface systems; -A cross-cutting theme calling for new laboratory studies on both natural and geo-architected subsurface materials that deploy advanced high-resolution 3D imaging and chemical analysis methods to determine the ;rates and mechanisms of fluid-rock processes, and to test predictive models of such phenomena. Many of the key energy challenges of the future demand a greater understanding of the subsurface world in all of its complexity. This greater under- standing will improve the ability to control and manipulate the subsurface world in ways that will benefit both the economy and the environment. This report provides specific basic research pathways to address some of the most fundamental issues of energy-related subsurface engineering.« less
Prey and mound disassembly, manipulation and transport by fire ant collectives
NASA Astrophysics Data System (ADS)
Dutta, Bahnisikha; Monaenkova, Daria; Goodisman, Michael A.; Goldman, Daniel
Fire ants inhabit subterranean nests covered by a hemispherical mound of soil permeated by narrow ( 1 body length diameter) tunnels. Fire ants can use their mound for long-term food storage [Gayahan &Tschinkel, J. Insect Sci.,2008]. Since mound tunnels are narrow, we expect that in addition to prey manipulation, mound reconfiguration could also be an important aspect of the food storage strategy. Ant colonies collected from wild were allowed to build nests in containers filled with clay soil in the laboratory. These colonies were offered diverse prey embedded with lead markers, including mealworms, crickets and shrimp. Ant-prey-soil interactions on the nest surface were recorded using overhead video and subsurface using x-ray imaging. Individual ants involved in prey storage exhibited three distinct behaviors: prey maneuvering, prey dissection and mound reconfiguration. Small prey (e.g. mealworms) were collectively carried intact into the mound through a tunnel, and then disassembled within the mound. Larger prey (e.g. shrimp) were dismantled into small pieces above the surface and carried to mound tunnels. The bodies of hard medium-sized prey (e.g. crickets) were buried after limb removal and then disassembled and moved into tunnels. Soil reconfiguration occurred in all cases.
NASA Astrophysics Data System (ADS)
Yang, Minghong; Qi, Hongji; Zhao, Yuanan; Yi, Kui
2012-01-01
The 355 nm laser-induced damage thresholds (LIDTs) of polished fused silica with and without the residual subsurface cracks were explored. HF based wet etching and magnetorheological finishing was used to remove the subsurface cracks. To isolate the effect of subsurface cracks, chemical leaching was used to eliminate the photoactive impurities in the polishing layer. Results show that the crack number density decreased from~103 to <1cm-2, and the LIDT was improved as high as 2.8-fold with both the subsurface cracks and the polishing layer being removed. Subsurface cracks play a significant role in laser damage at fluencies between 15~31 J/cm2 (355nm, 8ns). HF Etching of the cracks was shown to increase the damage performance as nearly high as that of the samples in which subsurface cracks are well controlled.
Effects of prescribed burning on marsh-elevation change and the risk of wetland loss
McKee, Karen L.; Grace, James B.
2012-01-01
Marsh-elevation change is the net effect of biophysical processes controlling inputs versus losses of soil volume. In many marshes, accumulation of organic matter is an important contributor to soil volume and vertical land building. In this study, we examined how prescribed burning, a common marsh-management practice, may affect elevation dynamics in the McFaddin National Wildlife Refuge, Texas by altering organic-matter accumulation. Experimental plots were established in a brackish marsh dominated by Spartina patens, a grass found throughout the Gulf of Mexico and Atlantic marshes. Experimental plots were subjected to burning and nutrient-addition treatments and monitored for 3.5 years (April 2005 – November 2008). Half of the plots were burned once in 2006; half of the plots were fertilized seasonally with nitrogen, phosphorus, and potassium. Before and after the burns, seasonal measurements were made of soil physicochemistry, vegetation structure, standing and fallen plant biomass, aboveground and belowground production, decomposition, and accretion and elevation change (measured with Surface Elevation Tables (SET)). Movements in different soil strata (surface, root zone, subroot zone) were evaluated to identify which processes were contributing to elevation change. Because several hurricanes occurred during the study period, we also assessed how these storms affected elevation change rates. The main findings of this study were as follows: 1. The main drivers of elevation change were accretion on the marsh surface and subsurface movement below the root zone, but the relative influence of these processes varied temporally. Prior to Hurricanes Gustav and Ike (September 2008), the main driver was subsurface movement; after the hurricane, both accretion and subsurface movement were important. 2. Prior to Hurricanes Gustav and Ike, rates of elevation gain and accretion above a marker horizon were higher in burned plots compared to nonburned plots, whereas nutrient addition had no detectable influence on elevation dynamics. 3. Burning decreased standing and fallen plant litter, reducing fuel load. Hurricanes Gustav and Ike also removed fallen litter from all plots. 4. Aboveground and belowground production rates varied annually but were unaffected by burning and nutrient treatments. 5. Decomposition (of a standard cellulose material) in upper soil layers was increased in burned plots but was unaffected by nutrient treatments. 6. Soil physicochemistry was unaffected by burning or nutrient treatments. 7. The elevation deficit (difference between rate of submergence and vertical land development) prior to hurricanes was less in burned plots (6.2 millimeters per year [mm yr-1]) compared to nonburned plots (7.2 mm yr-1). 8. Storm sediments delivered by Hurricane Ike raised elevations an average of 7.4 centimeters (cm), which countered an elevation deficit that had accrued over 11 years. Our findings provide preliminary insights into elevation dynamics occurring in brackish marshes of the Texas Chenier Plain under prescribed fire management. The results of this study indicate that prescribed burning conducted at 3- to 5-year intervals is not likely to negatively impact the long-term sustainability of S. patens-dominated brackish marshes at McFaddin National Wildlife Refuge and may offset existing elevation deficits by ≈ 1 mm yr-1. The primary drivers of elevation change varied in time and space, leading to a more complex situation in terms of predicting how disturbances may alter elevation trajectories. The potential effect of burning on elevation change in other marshes will depend on several site-specific factors, including geomorphic/ sedimentary setting, tide range, local rate of relative sea level rise, plant species composition, additional management practices (for example, for flood control), and disturbance types and frequency (for example, hurricanes or herbivore grazing). Increasing the scope of inference would require installation of SETs in replicate marshes undergoing different prescribed fire intervals and in different geomorphic settings (with different hurricane frequencies and/or different sedimentary settings). Multiple locations along the Gulf and Atlantic coasts where prescribed fire is used as a management tool could provide the appropriate setting for these installations.
Sorption of Perfluorochemicals to Matrices Relevant to Sites Impacted by Aqueous Film-Forming Foam
NASA Astrophysics Data System (ADS)
Sepulvado, J.; Higgins, C.
2011-12-01
Perfluorochemicals are a class of emerging contaminants consisting of fluorinated surfactants that are chemically and thermally stable and which contain a fluorocarbon tail that is both hydro- and oleophobic. Because of these unique properties, PFCs have a wide variety of uses including food paper packaging products, stain repellants, nonstick coatings, and aqueous film-forming foams (AFFF). At fire-training facilities, repeated application of AFFF is used to extinguish hydrocarbon fuel fires ignited for training purposes. The presence of perfluochemicals (PFCs) in groundwater as a result of repeated AFFF application at these facilities has been documented. Due to factors such as the recent push towards regulation of PFCs in drinking water, concerns have arisen about the fate of these compounds in the subsurface. Groundwater plumes containing PFC subclasses such as perfluorocarboxylic acids (PFCAs), perfluoroalkylsulfonates (PFAS), and fluorotelomer sulfonates (FtSs) in the μg/L to mg/L range have been detected. These plumes also may contain co-contaminants such as hydrocarbon fuel components and chlorinated solvents, some of which may exist as nonaqueous phase liquids (NAPL). This study examined the sorption of PFCs to soil and aquifer material across the concentration range applicable to AFFF-impacted sites (μg/L - mg/L) and looked at the impact of co-contaminants, including NAPL, on PFC sorption. PFC sorption was variable and indicated that similar to previous work on PFC sorption to sediment, subsurface PFC transport will depend on factors such as the sorbent organic carbon content, PFC subclass, solution chemistry, and PFC chain length.
De Luis, M; Raventós, J; González-Hidalgo, J C
2005-07-01
In Western Mediterranean areas, fires are frequent in forests established on old croplands where woody resprouting species are scarce and post-fire regeneration is limited to obligate-seeder species, such as Mediterranean gorse (Ulex parviflorus), that accumulate a great deal of fine dry fuel, increasing the risk of other severe fires. Under these conditions, fuel control techniques are required in order to prevent fires of high intensity and severity and the subsequent economic and ecological damage. Prescribed fires present an alternative to fuel control, and recent studies demonstrate that, under optimum climatic conditions, fire-line intensity values fall within the limits of those recommended for fire prescription. However, a better understanding of the consequences of fire on the regeneration of vegetation is needed in order to evaluate the suitability of prescribed fires as a technique for fuel reduction in Mediterranean gorse ecosystems. This paper analyses the factors controlling seedling germination after fire to make an evaluation from an ecological perspective of whether fire prescription is a suitable technique for fuel control in mature Mediterranean gorse shrublands. The results show that small differences in the composition of vegetation play a decisive role in fire behaviour, and have a decisive influence on the system's capacity for regeneration. Fire severity is low in mixed Mediterranean gorse communities with a low continuity of dead fine fuel (including Cistus sp., Rosmarinus sp., etc.) and fire creates a wide range of microhabitats where seedling emergence is high. In contrast, where U. parviflorus is more dominant, fire severity is higher and the regeneration of vegetation could be hindered. Our conclusions suggest that detailed studies of the composition of plant communities are required in order to decide whether prescribed burning should be applied.
Multi-scale controls of historical forest-fire regimes: new insights from fire-scar networks
Donald A. Falk; Emily K. Heyerdahl; Peter M. Brown; Calvin Farris; Peter Z. Fule; Donald McKenzie; Thomas W. Swetnam; Alan H. Taylor; Megan L. Van Horne
2011-01-01
Anticipating future forest-fire regimes under changing climate requires that scientists and natural resource managers understand the factors that control fire across space and time. Fire scarsâproxy records of fires, formed in the growth rings of long-lived treesâprovide an annually accurate window into past low-severity fire regimes. In western North America, networks...
Analysis of the Large Urban Fire Environment. Part 1. Theory
1982-07-01
the fire. It is the buoyancy-generated pressure forces, and not diffusive entrainment, that control the low-level induction of ambient air into the...18-- IV. RESULTS FLAMBEAU FIRES The multiple-fuel-bed Flambeau fires (Countryman, 1969; Palmer, 1981] were large, controlled burns conducted to...Station Northern Forest Fire Laboratory Alexandria, VA 22314 (12) Missoula, MT 59801 (1) Department of Defense 2. Mr. Clay F. Butler Command and Control
Digitally controlled twelve-pulse firing generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berde, D.; Ferrara, A.A.
1981-01-01
Control System Studies for the Tokamak Fusion Test Reactor (TFTR) indicate that accurate thyristor firing in the AC-to-DC conversion system is required in order to achieve good regulation of the various field currents. Rapid update and exact firing angle control are required to avoid instabilities, large eddy currents, or parasitic oscillations. The Prototype Firing Generator was designed to satisfy these requirements. To achieve the required /plus or minus/0.77/degree/firing accuracy, a three-phase-locked loop reference was designed; otherwise, the Firing Generator employs digital circuitry. The unit, housed in a standard CAMAC crate, operates under microcomputer control. Functions are performed under program control,more » which resides in nonvolatile read-only memory. Communication with CICADA control system is provided via an 11-bit parallel interface.« less
NASA Technical Reports Server (NTRS)
Saveker, D. R. (Editor)
1973-01-01
The preliminary design of a satellite plus computer earth resources information system is proposed for potential uses in fire prevention and control in the wildland fire community. Suggested are satellite characteristics, sensor characteristics, discrimination algorithms, data communication techniques, data processing requirements, display characteristics, and costs in achieving the integrated wildland fire information system.
Fire Resistance of Large-Scale Cross-Laminated Timber Panels
NASA Astrophysics Data System (ADS)
Henek, Vladan; Venkrbec, Václav; Novotný, Miloslav
2017-12-01
Wooden structures are increasingly being used in the construction of residential buildings. A common and often published reason to avoid wooden structures is their insufficient fire resistance, which reduces bearing capacity. For this reason, composite sandwich structures began to be designed to eliminate this drawback, as well as others. Recently, however, the trend is for a return to the original, wood-only variant and a search is underway for new technical means of improving the properties of such structures. Many timber structure technologies are known, but structures made from cross-laminated timber (CLT) panels have been used very often in recent years. CLT panels, also known as X-LAM, are currently gaining popularity in Europe. In the case of CLT panels composed of several layers of boards, they can be said to offer a certain advantage in that after the surface layer of a board has burnt and the subsurface layer has dried, oxygen is not drawn to the unburned wood for further combustion and thus the burning process ceases. CLT panels do not need to be specially modified or coated with fire resistant materials, although they are usually lined with gypsum-fibre fire resistant boards due to guidelines set out in the relevant standards. This paper presents a new method for the assessment of load-bearing perimeter walls fabricated from CLT panels without the use of an inner fire-retardant lining to ensure fire resistance at the level required by European standards (i.e. those harmonized for the Czech construction industry). The calculations were verified through laboratory tests which show that better parameters can be achieved during the classification of structures from the fire resistance point of view. The aim of the article is to utilize the results of assessment and testing by an accredited laboratory in order to demonstrate the possibilities of using CLT panels for the construction of multistorey as well as multi-purpose buildings in the Czech Republic.
Liu, Zhihua; Yang, Jian; He, Hong S.
2013-01-01
The relative importance of fuel, topography, and weather on fire spread varies at different spatial scales, but how the relative importance of these controls respond to changing spatial scales is poorly understood. We designed a “moving window” resampling technique that allowed us to quantify the relative importance of controls on fire spread at continuous spatial scales using boosted regression trees methods. This quantification allowed us to identify the threshold value for fire size at which the dominant control switches from fuel at small sizes to weather at large sizes. Topography had a fluctuating effect on fire spread across the spatial scales, explaining 20–30% of relative importance. With increasing fire size, the dominant control switched from bottom-up controls (fuel and topography) to top-down controls (weather). Our analysis suggested that there is a threshold for fire size, above which fires are driven primarily by weather and more likely lead to larger fire size. We suggest that this threshold, which may be ecosystem-specific, can be identified using our “moving window” resampling technique. Although the threshold derived from this analytical method may rely heavily on the sampling technique, our study introduced an easily implemented approach to identify scale thresholds in wildfire regimes. PMID:23383247
Kazerooni, Yasaman; Gyedu, Adam; Burnham, Gilbert; Nwomeh, Benedict; Charles, Anthony; Mishra, Brijesh; Kuah, Solomon S; Kushner, Adam L; Stewart, Barclay T
2015-01-01
Introduction We aimed to describe the burden of fires in displaced persons settlements and identify interventions/innovations that might address gaps in current humanitarian guidelines. Methods We performed a systematic review of: i) academic and non-academic literature databases; and ii) guidelines from leading humanitarian agencies/initiatives regarding fire prevention/control. Results Of the 1,521 records retrieved, 131 reports described settlement fires in 31 hosting countries since 1990. These incidents resulted in 487 deaths, 790 burn injuries, displacement of 382,486 individuals and destruction of 50,509 shelters. There was a 25-fold increase in the rate of settlement fires from 1990 to 2015 (0.002 to 0.051 per 100,000 refugees, respectively). Only 4 of the 15 leading humanitarian agencies provided recommendations about fire prevention/control strategies. Potentially useful interventions/innovations included safer stoves (e.g. solar cookers) and fire retardant shelter materials. Conclusion The large and increasing number of fires in displaced persons settlements highlights the need to redress gaps in humanitarian fire prevention/control guidelines. The way forward includes: i) developing consensus among aid agencies regarding fire prevention/control strategies; ii) evaluating the impact of interventions/innovations on the burden of fires; and iii) engaging agencies in a broader discussion about protecting camp residents from armed groups. PMID:26818955
Kazerooni, Yasaman; Gyedu, Adam; Burnham, Gilbert; Nwomeh, Benedict; Charles, Anthony; Mishra, Brijesh; Kuah, Solomon S; Kushner, Adam L; Stewart, Barclay T
2016-08-01
We aimed to describe the burden of fires in displaced persons settlements and identify interventions/innovations that might address gaps in current humanitarian guidelines. We performed a systematic review of: (i) academic and non-academic literature databases; and (ii) guidelines from leading humanitarian agencies/initiatives regarding fire prevention/control. Of the 1521 records retrieved, 131 reports described settlement fires in 31 hosting countries since 1990. These incidents resulted in 487 deaths, 790 burn injuries, displacement of 382,486 individuals and destruction of 50,509 shelters. There was a 25-fold increase in the rate of settlement fires from 1990 to 2015 (0.002-0.051 per 100,000 refugees, respectively). Only 4 of the 15 leading humanitarian agencies provided recommendations about fire prevention/control strategies. Potentially useful interventions/innovations included safer stoves (e.g. solar cookers) and fire retardant shelter materials. The large and increasing number of fires in displaced persons settlements highlights the need to redress gaps in humanitarian fire prevention/control guidelines. The way forward includes: (i) developing consensus among aid agencies regarding fire prevention/control strategies; (ii) evaluating the impact of interventions/innovations on the burden of fires; and (iii) engaging agencies in a broader discussion about protecting camp residents from armed groups. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
43 CFR 6304.22 - What special provisions apply to control of fire, insects, and diseases?
Code of Federal Regulations, 2011 CFR
2011-10-01
... of fire, insects, and diseases? 6304.22 Section 6304.22 Public Lands: Interior Regulations Relating... apply to control of fire, insects, and diseases? BLM may prescribe measures to control fire, noxious weeds, non-native invasive plants, insects, and diseases. BLM may require restoration concurrent with or...
43 CFR 6304.22 - What special provisions apply to control of fire, insects, and diseases?
Code of Federal Regulations, 2013 CFR
2013-10-01
... of fire, insects, and diseases? 6304.22 Section 6304.22 Public Lands: Interior Regulations Relating... apply to control of fire, insects, and diseases? BLM may prescribe measures to control fire, noxious weeds, non-native invasive plants, insects, and diseases. BLM may require restoration concurrent with or...
43 CFR 6304.22 - What special provisions apply to control of fire, insects, and diseases?
Code of Federal Regulations, 2014 CFR
2014-10-01
... of fire, insects, and diseases? 6304.22 Section 6304.22 Public Lands: Interior Regulations Relating... apply to control of fire, insects, and diseases? BLM may prescribe measures to control fire, noxious weeds, non-native invasive plants, insects, and diseases. BLM may require restoration concurrent with or...
43 CFR 6304.22 - What special provisions apply to control of fire, insects, and diseases?
Code of Federal Regulations, 2012 CFR
2012-10-01
... of fire, insects, and diseases? 6304.22 Section 6304.22 Public Lands: Interior Regulations Relating... apply to control of fire, insects, and diseases? BLM may prescribe measures to control fire, noxious weeds, non-native invasive plants, insects, and diseases. BLM may require restoration concurrent with or...
PEO Ammunition Systems Portfolio Book 2012-2013
2011-02-02
assembly. Aluminum ogive contains firing pin, a rubber anti-creep spring and M550 fuze escapement assembly and is threaded to projectile body...51 The Mortar Weapons and Fire Control Family M95/M96 Mortar Fire Control System (MFCS) – Mounted...52 M150/M151 Mortar Fire Control System Dismounted (MFCS-D
The Science of Prescribed Fire: to Enable a Different Kind of Control
Timothy E. Paysen; Marcia G. Narog; Jack D. Cohen
1998-01-01
A paradigm shift from fire suppression to fire suppression and prescription requires a shift in emphasis from simply controlling wildfire occurrence and spread to one that includes controlling characteristics of prescribed fire. Suppression focuses on preventing unwanted effects that might result from wildfire occurrence. Prescription promotes desired effects by...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 5 2014-01-01 2014-01-01 false Imported fire ant detection, control, exclusion, and..., DEPARTMENT OF AGRICULTURE DOMESTIC QUARANTINE NOTICES Imported Fire Ant Quarantine and Regulations § 301.81-11 Imported fire ant detection, control, exclusion, and enforcement program for nurseries producing...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 5 2011-01-01 2011-01-01 false Imported fire ant detection, control, exclusion, and..., DEPARTMENT OF AGRICULTURE DOMESTIC QUARANTINE NOTICES Imported Fire Ant Quarantine and Regulations § 301.81-11 Imported fire ant detection, control, exclusion, and enforcement program for nurseries producing...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 5 2012-01-01 2012-01-01 false Imported fire ant detection, control, exclusion, and..., DEPARTMENT OF AGRICULTURE DOMESTIC QUARANTINE NOTICES Imported Fire Ant Quarantine and Regulations § 301.81-11 Imported fire ant detection, control, exclusion, and enforcement program for nurseries producing...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 5 2013-01-01 2013-01-01 false Imported fire ant detection, control, exclusion, and..., DEPARTMENT OF AGRICULTURE DOMESTIC QUARANTINE NOTICES Imported Fire Ant Quarantine and Regulations § 301.81-11 Imported fire ant detection, control, exclusion, and enforcement program for nurseries producing...
Clare, Joseph; Garis, Len; Plecas, Darryl; Jennings, Charles
2012-04-01
In 2008, Surrey Fire Services, British Columbia, commenced a firefighter-delivered, door-to-door fire-prevention education and smoke alarm examination/installation initiative with the intention of reducing the frequency and severity of residential structure fires in the City of Surrey. High-risk zones within the city were identified and 18,473 home visits were undertaken across seven temporal delivery cohorts (13.8% of non-apartment dwellings in the city). The frequency and severity of fires pre- and post- the home visit intervention was examined in comparison to randomized high-risk cluster controls. Overall, the frequency of fires was found to have reduced in the city overall, however, the reduction in the intervention cohorts was significantly larger than for controls. Furthermore, when fires did occur within the intervention cohorts, smoke detectors were activated more frequently and the fires were confined to the object of origin more often post-home visits. No equivalent pattern was observed for the cluster control. On-duty fire fighters can reduce the frequency and severity of residential fires through targeted, door-to-door distribution of fire prevention education in high-risk areas. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Froemyr, E.; Berteussen, K.A.; Jahren, L.
Small scale seismic surveys have the potential of providing low-cost high resolution subsurface images of limited targets. Crucial to the success of this method is to understand the character and level of ambient noise. Based on this understanding appropriate source strength and receiver fold can be determined in order to obtain the necessary signal to noise ratio at target depth. Saga Petroleum a.s. and Read Well Services A/S performed a test off-shore Norway using geophones on the seabed. The receivers consisted of two small geophone arrays separated by 1 km. A 3 km line was host symmetrically above the receivermore » arrays. The line was shot in a non-continuous fashion by moving from one position to the next with 5 repetitive shots fired at each shot position. A small airgun array was used. A large proportion of the noise exhibits clear spatial coherence. The most significant noise sources are the receiver vessel and the shooting boat. Spectral and spatial analysis reveals that additional sources of noise are present including subsurface sources. The target reflector was top reservoir at approximately 2.1 sec. two-way time. With 4 geophones in each array and repetitive shooting, top reservoir is visible but weak. The area is in general complex but the authors may infer that reduce vessel noise coupled with increased source strength can provide a high resolution subsurface image revealing details not seen on the standard marine seismic section.« less
Maureen C. Kennedy; Donald McKenzie
2010-01-01
Fire-scarred trees provide a deep temporal record of historical fire activity, but identifying the mechanisms therein that controlled landscape fire patterns is not straightforward. We use a spatially correlated metric for fire co-occurrence between pairs of trees (the Sørensen distance variogram), with output from a neutral model for fire history, to infer the...
Phosphorus runoff losses from subsurface-applied poultry litter on coastal plain soils.
Kibet, Leonard C; Allen, Arthur L; Kleinman, Peter J A; Feyereisen, Gary W; Church, Clinton; Saporito, Lou S; Way, Thomas R
2011-01-01
The application of poultry litter to soils is a water quality concern on the Delmarva Peninsula, as runoff contributes P to the eutrophic Chesapeake Bay. This study compared a new subsurface applicator for poultry litter with conventional surface application and tillage incorporation of litter on a Coastal Plain soil under no-till management. Monolith lysimeters (61 cm by 61 cm by 61 cm) were collected immediately after litter application and subjected to rainfall simulation (61 mm h(-1) 1 h) 15 and 42 d later. In the first rainfall event, subsurface application of litter significantly lowered total P losses in runoff (1.90 kg ha(-1)) compared with surface application (4.78 kg ha(-1)). Losses of P with subsurface application were not significantly different from disked litter or an unamended control. By the second event, total P losses did not differ significantly between surface and subsurface litter treatments but were at least twofold greater than losses from the disked and control treatments. A rising water table in the second event likely mobilized dissolved forms of P in subsurface-applied litter to the soil surface, enriching runoff water with P. Across both events, subsurface application of litter did not significantly decrease cumulative losses of P relative to surface-applied litter, whereas disking the litter into the soil did. Results confirm the short-term reduction of runoff P losses with subsurface litter application observed elsewhere but highlight the modifying effect of soil hydrology on this technology's ability to minimize P loss in runoff.
Response Mechanism: Blast/Fire Interactions.
1983-11-01
A WORK UNIT NUMBERS University of Notre Dame Notre Dame, IN L FEMA WU No. 2564H ItI. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE Fedqral...Fires 9 Class A Fires 10 Control by Physics or Chemistry? 11 Conments 14 EXTINCTION AND IGNITION 15 Pool Fire 15 Analysis 17 Charring Solid Fire 21...post-explosion time, although its magnitude may make the efforts to control appear futile in the wake of a nuclear attack. There is considerable
Subsurface Contamination Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Y. Yuan
There are two objectives of this report, ''Subsurface Contamination Control''. The first is to provide a technical basis for recommending limiting radioactive contamination levels (LRCL) on the external surfaces of waste packages (WP) for acceptance into the subsurface repository. The second is to provide an evaluation of the magnitude of potential releases from a defective WP and the detectability of the released contents. The technical basis for deriving LRCL has been established in ''Retrieval Equipment and Strategy for Wp on Pallet'' (CRWMS M and O 2000g, 6.3.1). This report updates the derivation by incorporating the latest design information of themore » subsurface repository for site recommendation. The derived LRCL on the external surface of WPs, therefore, supercede that described in CRWMS M and O 2000g. The derived LRCL represent the average concentrations of contamination on the external surfaces of each WP that must not be exceeded before the WP is to be transported to the subsurface facility for emplacement. The evaluation of potential releases is necessary to control the potential contamination of the subsurface repository and to detect prematurely failed WPs. The detection of failed WPs is required in order to provide reasonable assurance that the integrity of each WP is intact prior to MGR closure. An emplaced WP may become breached due to manufacturing defects or improper weld combined with failure to detect the defect, by corrosion, or by mechanical penetration due to accidents or rockfall conditions. The breached WP may release its gaseous and volatile radionuclide content to the subsurface environment and result in contaminating the subsurface facility. The scope of this analysis is limited to radioactive contaminants resulting from breached WPs during the preclosure period of the subsurface repository. This report: (1) documents a method for deriving LRCL on the external surfaces of WP for acceptance into the subsurface repository; (2) provides a table of derived LRCL for nuclides of radiological importance; (3) Provides an as low as is reasonably achievable (ALARA) evaluation of the derived LRCL by comparing potential onsite and offsite doses to documented ALARA requirements; (4) Provides a method for estimating potential releases from a defective WP; (5) Provides an evaluation of potential radioactive releases from a defective WP that may become airborne and result in contamination of the subsurface facility; and (6) Provides a preliminary analysis of the detectability of a potential WP leak to support the design of an airborne release monitoring system.« less
Weak climatic control of stand-scale fire history during the late holocene.
Gavin, Daniel G; Hu, Feng Sheng; Lertzman, Kenneth; Corbett, Peter
2006-07-01
Forest fire occurrence is affected by multiple controls that operate at local to regional scales. At the spatial scale of forest stands, regional climatic controls may be obscured by local controls (e.g., stochastic ignitions, topography, and fuel loads), but the long-term role of such local controls is poorly understood. We report here stand-scale (<100 ha) fire histories of the past 5000 years based on the analysis of sediment charcoal at two lakes 11 km apart in southeastern British Columbia. The two lakes are today located in similar subalpine forests, and they likely have experienced the same late-Holocene climatic changes because of their close proximity. We evaluated two independent properties of fire history: (1) fire-interval distribution, a measure of the overall incidence of fire, and (2) fire synchroneity, a measure of the co-occurrence of fire (here, assessed at centennial to millennial time scales due to the resolution of sediment records). Fire-interval distributions differed between the sites prior to, but not after, 2500 yr before present. When the entire 5000-yr period is considered, no statistical synchrony between fire-episode dates existed between the two sites at any temporal scale, but for the last 2500 yr marginal levels of synchrony occurred at centennial scales. Each individual fire record exhibited little coherency with regional climate changes. In contrast, variations in the composite record (average of both sites) matched variations in climate evidenced by late-Holocene glacial advances. This was probably due to the increased sample size and spatial extent represented by the composite record (up to 200 ha) plus increased regional climatic variability over the last several millennia, which may have partially overridden local, non-climatic controls. We conclude that (1) over past millennia, neighboring stands with similar modern conditions may have experienced different fire intervals and asynchronous patterns in fire episodes, likely because local controls outweighed the synchronizing effect of climate; (2) the influence of climate on fire occurrence is more strongly expressed when climatic variability is relatively great; and (3) multiple records from a region are essential if climate-fire relations are to be reliably described.
On the evidence for human use and control of fire at Schöningen.
Stahlschmidt, Mareike C; Miller, Christopher E; Ligouis, Bertrand; Hambach, Ulrich; Goldberg, Paul; Berna, Francesco; Richter, Daniel; Urban, Brigitte; Serangeli, Jordi; Conard, Nicholas J
2015-12-01
When and how humans began to control fire has been a central debate in Paleolithic archaeology for decades. Fire plays an important role in technology, social organization, subsistence, and manipulation of the environment and is widely seen as a necessary adaptation for the colonization of northern latitudes. Many researchers view purported hearths, burnt wooden implements, and heated flints from Schöningen as providing the best evidence for the control of fire in the Lower Paleolithic of Northern Europe. Here we present results of a multianalytical study of the purported hearths along with a critical examination of other possible evidence of human use or control of fire at Schöningen. We conclude that the analyzed features and artifacts present no convincing evidence for human use or control of fire. Our study also shows that a multianalytical, micro-contextual approach is the best methodology for evaluating claims of early evidence of human-controlled fire. We advise caution with macroscopic, qualitative identification of combustion features, burnt flint, and burnt wood without the application of such techniques as micromorphology, Fourier transform infrared (FTIR) spectroscopy, organic petrology, luminescence, and analysis of mineral magnetic parameters. The lack of evidence for the human control of fire at Schöningen raises the possibility that fire control was not a necessary adaptation for the human settlement of northern latitudes in the Lower Paleolithic. Copyright © 2015 Elsevier Ltd. All rights reserved.
2012-11-16
CAPE CANAVERAL, Fla. – Firing Room 1, also known as the Young-Crippen Firing Room, has been outfitted with computer, communications and networking systems to host rockets and spacecraft that are currently under development. The firing room is where the launch of rockets and spacecraft are controlled at NASA's Kennedy Space Center in Florida. Flight controllers also monitor processing and preparations of launch vehicles from the firing room. There are four firing rooms inside the Launch Control Center at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
2012-11-16
CAPE CANAVERAL, Fla. – Firing Room 1, also known as the Young-Crippen Firing Room, has been outfitted with computer, communications and networking systems to host rockets and spacecraft that are currently under development. The firing room is where the launch of rockets and spacecraft are controlled at NASA's Kennedy Space Center in Florida. Flight controllers also monitor processing and preparations of launch vehicles from the firing room. There are four firing rooms inside the Launch Control Center at Kennedy. Photo credit: NASA/Dmitri Gerondidakis
Hornby's principles of fire control planning
H. T. Gisborne
1939-01-01
On August 27, 1937, Lloyd G. Hornby died of heart failure on the Toboggan Creek forest fire in the Clearwater National Forest. Few if any men in or out of the U.S. Forest Service have made a greater contribution to fire control planning than did he. In the following article, H. T. Gisborne outlines the principles of fire control planning developed by Mr. Hornby,...
46 CFR 116.433 - Windows and air ports in fire control boundaries.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Windows and air ports in fire control boundaries. 116... CONSTRUCTION AND ARRANGEMENT Fire Protection § 116.433 Windows and air ports in fire control boundaries. (a) Windows or air ports must be of tempered or laminated glass of at least 6.5 millimeters (0.25 inches) in...
14 CFR 27.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...
14 CFR 27.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...
14 CFR 29.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...
14 CFR 29.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...
Code of Federal Regulations, 2011 CFR
2011-10-01
... pressures specified in § 193.10-5(i)(1)(i). (2) Remote control of fire pumps. (i) At least one fire pump must be capable of remote activation and control. (ii) If the fire pump is in a continuously manned... 46 Shipping 7 2011-10-01 2011-10-01 false Fire pumps. 193.10-5 Section 193.10-5 Shipping COAST...
Spatial controls of occurrence and spread of wildfires in the Missouri Ozark Highlands.
Yang, Jian; He, Hong S; Shifley, Stephen R
2008-07-01
Understanding spatial controls on wildfires is important when designing adaptive fire management plans and optimizing fuel treatment locations on a forest landscape. Previous research about this topic focused primarily on spatial controls for fire origin locations alone. Fire spread and behavior were largely overlooked. This paper contrasts the relative importance of biotic, abiotic, and anthropogenic constraints on the spatial pattern of fire occurrence with that on burn probability (i.e., the probability that fire will spread to a particular location). Spatial point pattern analysis and landscape succession fire model (LANDIS) were used to create maps to show the contrast. We quantified spatial controls on both fire occurrence and fire spread in the Midwest Ozark Highlands region, USA. This area exhibits a typical anthropogenic surface fire regime. We found that (1) human accessibility and land ownership were primary limiting factors in shaping clustered fire origin locations; (2) vegetation and topography had a negligible influence on fire occurrence in this anthropogenic regime; (3) burn probability was higher in grassland and open woodland than in closed-canopy forest, even though fire occurrence density was less in these vegetation types; and (4) biotic and abiotic factors were secondary descriptive ingredients for determining the spatial patterns of burn probability. This study demonstrates how fire occurrence and spread interact with landscape patterns to affect the spatial distribution of wildfire risk. The application of spatial point pattern data analysis would also be valuable to researchers working on landscape forest fire models to integrate historical ignition location patterns in fire simulation.
NASA Astrophysics Data System (ADS)
Burgess, P. M.; Steel, R. J.
2016-12-01
Decoding a history of Earth's surface dynamics from strata requires robust quantitative understanding of supply and accommodation controls. The concept of stratigraphic solution sets has proven useful in this decoding, but application and development of this approach has so far been surprisingly limited. Stratal control volumes, areas and trajectories are new approaches defined here, building on previous ideas about stratigraphic solution sets, to help analyse and understand the sedimentary record of Earth surface dynamics. They may have particular application reconciling results from outcrop and subsurface analysis with results from analogue and numerical experiments. Stratal control volumes are sets of points in a three-dimensional volume, with axes of subsidence, sediment supply and eustatic rates of change, populated with probabilities derived from analysis of subsidence, supply and eustasy timeseries (Figure 1). These empirical probabilities indicate the likelihood of occurrence of any particular combination of control rates defined by any point in the volume. The stratal control volume can then by analysed to determine which parts of the volume represent relative sea-level fall and rise, where in the volume particular stacking patterns will occur, and how probable those stacking patterns are. For outcrop and subsurface analysis, using a stratal control area with eustasy and subsidence combined on a relative sea-level axis allows similar analysis, and may be preferable. A stratal control trajectory is a history of supply and accommodation creation rates, interpreted from outcrop or subsurface data, or observed in analogue and numerical experiments, and plotted as a series of linked points forming a trajectory through the stratal control volume (Figure 1) or area. Three examples are presented, one from outcrop and two theoretical. Much work remains to be done to build a properly representative database of stratal controls, but careful comparison of stratal control volume and trajectories constructed from outcrop analysis, subsurface analysis and experimental models may help the convergence, reconciliation and future evolution of these different approaches.
Hydrogeological controls on post-fire moss recovery in peatlands
NASA Astrophysics Data System (ADS)
Lukenbach, M. C.; Devito, K. J.; Kettridge, N.; Petrone, R. M.; Waddington, J. M.
2015-11-01
Wildfire is the largest disturbance affecting boreal peatlands, however, little is known about the controls on post-fire peatland vegetation recovery. While small-scale variation in burn severity can reduce post-fire moss water availability, high water table (WT) positions following wildfire are also critical to enable the re-establishment of keystone peatland mosses (i.e. Sphagnum). Thus, post-fire moss water availability is also likely a function of landscape-scale controls on peatland WT dynamics, specifically, connectivity to groundwater flow systems (i.e. hydrogeological setting). For this reason, we assessed the interacting controls of hydrogeological setting and burn severity on post-fire moss water availability in three burned, Sphagnum-dominated peatlands in Alberta's Boreal Plains. At all sites, variation in burn severity resulted in a dichotomy between post-fire surface covers that: (1) exhibited low water availability, regardless of WT position, and had minimal (<5%) moss re-establishment (i.e. lightly burned feather mosses and severely burned Sphagnum fuscum) or (2) exhibited high water availability, depending on WT position, and had substantial (>50%) moss re-establishment (i.e. lightly burned S. fuscum and where depth of burn was >0.05 m). Notably, hydrogeological setting influenced the spatial coverage of these post-fire surface covers by influencing pre-fire WTs and stand characteristics (e.g., shading). Because feather moss cover is controlled by tree shading, lightly burned feather mosses were ubiquitous (>25%) in drier peatlands (deeper pre-fire WTs) that were densely treed and had little connection to large groundwater flow systems. Moreover, hydrogeological setting also controlled post-fire WT positions, thereby affecting moss re-establishment in post-fire surface covers that were dependent on WT position (e.g., lightly burned S. fuscum). Accordingly, higher recolonization rates were observed in a peatland located in a groundwater flow through system that had a shallow post-fire WT. Therefore, we argue that hydrogeological setting influences post-fire recovery in two ways: (1) by influencing vegetation structure prior to wildfire, thereby controlling the coverage of post-fire surface covers and (2) by influencing post-fire WT positions. These results suggest that post-fire moss recovery in peatlands isolated from groundwater flow systems may be particularly susceptible to droughts and future climate change.
Radar Imaging of Europa's Subsurface Properties and Processes: The View from Earth
NASA Astrophysics Data System (ADS)
Blankenship, D. D.; Moore, W. B.; Young, D. A.; Peters, M. E.
2007-12-01
A primary objective of future Europa studies will be to characterize the distribution of shallow subsurface water as well as to identify any ice-ocean interface. Another objective will be to understand the formation of surface and subsurface features associated with interchange processes between any ocean and the surface. Achieving these objectives will require either direct or inferred knowledge of the position of any ice/water interfaces as well as any brine or layer pockets. We will review the hypothesized processes that control the thermal, compositional and structural (TCS) properties, and therefore the dielectric character, of the subsurface of Europa's icy shell. Our approach will be to extract the TCS properties for various subsurface processes thought to control the formation of major surface (e.g., ridges/bands, lenticulae, chaos, cratering...) and subsurface (e.g., rigid shell eutectics, diapirs, accretionary lenses ...) features on Europa. We will then assess the spectrum of analog processes and TCS properties represented by Earth's cryosphere including both Arctic and Antarctic ice sheets, ice shelves and valley glaciers. There are few complete analogs over the full TCS space but, because of the wide range of ice thickness, impurities and strain rates for Earth's cryosphere, there are many more analogs than many Earth and planetary researchers might imagine for significant portions of this space (e.g., bottom crevasses, marine ice shelf/subglacial lake accretion, surging polythermal glaciers...).Our ultimate objective is to use these Earth analog studies to define the radar imaging approach for Europa's subsurface that will be most useful for supporting/refuting the hypotheses for the formation of major surface/subsurface features as well as for "pure" exploration of Europa's icy shell and its interface with the underlying ocean.
6. UNDERGROUND FIRING CONTROL ROOM, INTERIOR. Looking southeast to escape ...
6. UNDERGROUND FIRING CONTROL ROOM, INTERIOR. Looking southeast to escape tunnel. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Herman, J.; den Ouden, J.; Mohren, G. M. J.; Retana, J.; Serrasolses, I.
2009-04-01
Changes in fire regime due to intensification of human influence during the last decades led to changes in vegetation structure and composition, productivity and carbon sink strength of Mediterranean shrublands and forests. It is anticipated that further climate warming and lower precipitation will enhance fire frequency, having consequences for the carbon budget and carbon storage in Mediterranean ecosystems. The purpose of this study was to determine whether fire recurrence modifies aboveground plant and soil carbon stocks, soil organic carbon content and total soil nitrogen content in shrublands with Aleppo pine on the Garraf Massif in Catalonia (Spain). Stands differing in fire frequency (1, 2 and 3 fires since 1957) were examined 13 years after the stand-replacing fire of 1994 and compared with control stands which were free of fire since 1957. Recurrent fires led to a decrease in total ecosystem carbon stocks. Control sites stored 12203 g m-2C which was 3.5, 5.0 and 5.5 times more than sites that burned 1, 2 and 3 times respectively. Carbon stored in the aboveground biomass exceeded soil carbon stocks in control plots, while soils were the dominant carbon pool in burned plots. An increasing fire frequency from 1 to 2 fires decreased total soil carbon stock. Control soils stored 3551 g m-2C, of which 70 % was recovered over 13 years in once burned soils and approximately 50 % in soils that had 2 or 3 fires. The soil litter (LF) layer carbon stock decreased with increasing fire frequency from 1 to 2 fires, whereas humus (H) layer and upper mineral soil carbon stocks did not change consistently with fire frequency. Fire decreased the organic carbon content in LF and H horizons, however no significant effect of fire frequency was found. Increasing fire frequency from 1 to 2 fires caused a decrease in the organic carbon content in the upper mineral soil. Total soil N content and C/N ratios were not significantly impacted by fire frequency. Recurrent fires had the greatest impact on aboveground plant carbon stocks. Aboveground plants in control plots amounted to 8652 g m-2C, of which 93 % was stored in trees, while carbon storage in the most frequently burned sites was only 509 g m-2C. Shrub carbon varied barely between fire frequencies, corroborating the high resilience of resprouting shrub species to fire recurrence. The most striking result was the immense decrease in Aleppo pine carbon stock which varied between 7770 g m-2in control plots and 25.6 g m-2in 3-fires plots. Differences between control and burned plots are principally explained by the age of the plots. The decrease in Aleppo pine carbon stock within burned plots was not associated with a growth reduction, but was due to a decrease in stem density. The results indeed indicate that the recruitment of Aleppo pine on more frequently burned plots is obstructed due to cumulative effects of short fire return-intervals (
SST Control by Subsurface Mixing During Indian Ocean Monsoons
2015-09-30
1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. SST Control by Subsurface Mixing during Indian Ocean ...quantify the variability in upper ocean mixing associated with changes in barrier layer thickness and strength across the BoB and under different...These objectives directly target the fundamental role that upper ocean dynamics play in the complex air-sea interactions of the northern Indian Ocean
Peat fires as source of polycyclic aromatic hydrocarbons in soils
NASA Astrophysics Data System (ADS)
Tsibart, Anna
2013-04-01
Polycyclic aromatic hydrocarbons (PAHs) arrive from pyrogenic sources including volcanism and the combustion of oil products and plant materials. The production of PAHs during the combustion of plant materials was considered in a number of publications, but their results were mainly obtained in laboratory experiments. Insufficient data are available on the hightemperature production of PAHs in environmental objects. For example, natural fires are frequently related to the PAH sources in landscapes, but very little factual data are available on this topic. On Polistovskii reserve (Russia, Pskov region) the soil series were separated depending on the damage to the plants; these series included soils of plots subjected to fires of different intensities, as well as soils of the background plots. The series of organic and organomineral soils significantly differed in their PAH distributions. In this series, the concentration of PAHs in the upper horizons of the peat soils little varied or slightly decreased, but their accumulation occurred at a depth of 5-10 or 10-20 cm in the soils after the fires. For example, in the series of high moor soils, the content of PAHs in the upper horizons remained almost constant; significant differences were observed in the subsurface horizons: from 2 ng/g in the background soil to 70 ng/g after the fire. In the upper horizons of the oligotrophic peat soils under pine forests, the total PAH content also varied only slightly. At the same time, the content of PAHs in the soil series increased from 15 to 90 ng/g with the increasing pyrogenic damage to the plot. No clear trends of the PAH accumulation were recorded in the organomineral soils. The content of PAHs in the soddy-podzolic soil subjected to fire slightly decreased (from 20 to 10 ng/g) compared to the less damaged soil. In peat fires, the access of oxygen to the fire zone is lower than in forest fires. The oxygen deficit acts as a factor of the organic fragments recombination and PAH production; therefore, larger amounts of PAHs are formed in peat fires. In addition, the peat fires occur directly in the soil layer; therefore, larger amounts of the resulting polyarenes remain in the soils of the fire sites. PAHs also can be formed at the heating of organic matter on the areas adjacent to the fire sites. After the combustion of peat in fires, phenanthrene, chrysene, benz[a]pyrene, and tetraphene accumulate in soils. This is mainly the group of 4-nuclear compounds with the participation of 3-nuclear phenanthrene and 5-nuclear benz[a]pyrene. The formation of high-molecular weight compounds like benz[a]pyrene and, in some places, benzo[ghi]perylene is possible during smoldering under a low oxygen supply.
Detonation command and control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, Jonathan Lee; Seitz, Gerald J.; Echave, John A.
The detonation of one or more explosive charges and propellant charges by a detonator in response to a fire control signal from a command and control system comprised of a command center and instrumentation center with a communications link therebetween. The fire control signal is selectively provided to the detonator from the instrumentation center if plural detonation control switches at the command center are in a fire authorization status, and instruments, and one or more interlocks, if included, are in a ready for firing status. The instrumentation and command centers are desirably mobile, such as being respective vehicles.
Detonation command and control
Mace, Jonathan L.; Seitz, Gerald J.; Echave, John A.; Le Bas, Pierre-Yves
2015-11-10
The detonation of one or more explosive charges and propellant charges by a detonator in response to a fire control signal from a command and control system comprised of a command center and instrumentation center with a communications link therebetween. The fire control signal is selectively provided to the detonator from the instrumentation center if plural detonation control switches at the command center are in a fire authorization status, and instruments, and one or more interlocks, if included, are in a ready for firing status. The instrumentation and command centers are desirably mobile, such as being respective vehicles.
Detonation command and control
Mace, Jonathan L.; Seitz, Gerald J.; Echave, John A.; Le Bas, Pierre-Yves
2016-05-31
The detonation of one or more explosive charges and propellant charges by a detonator in response to a fire control signal from a command and control system comprised of a command center and instrumentation center with a communications link there between. The fire control signal is selectively provided to the detonator from the instrumentation center if plural detonation control switches at the command center are in a fire authorization status, and instruments, and one or more interlocks, if included, are in a ready for firing status. The instrumentation and command centers are desirably mobile, such as being respective vehicles.
NASA Technical Reports Server (NTRS)
Kuo, Kenneth K.; Lu, Yeu-Cherng; Chiaverini, Martin J.; Harting, George C.; Johnson, David K.; Serin, Nadir
1995-01-01
The experimental study on the fundamental processes involved in fuel decomposition and boundary-layer combustion in hybrid rocket motors is continuously being conducted at the High Pressure Combustion Laboratory of The Pennsylvania State University. This research will provide a useful engineering technology base in the development of hybrid rocket motors as well as a fundamental understanding of the complex processes involved in hybrid propulsion. A high-pressure, 2-D slab motor has been designed, manufactured, and utilized for conducting seven test firings using HTPB fuel processed at PSU. A total of 20 fuel slabs have been received from the Mcdonnell Douglas Aerospace Corporation. Ten of these fuel slabs contain an array of fine-wire thermocouples for measuring solid fuel surface and subsurface temperatures. Diagnostic instrumentation used in the test include high-frequency pressure transducers for measuring static and dynamic motor pressures and fine-wire thermocouples for measuring solid fuel surface and subsurface temperatures. The ultrasonic pulse-echo technique as well as a real-time x-ray radiography system have been used to obtain independent measurements of instantaneous solid fuel regression rates.
NASA Astrophysics Data System (ADS)
Kuo, Kenneth K.; Lu, Yeu-Cherng; Chiaverini, Martin J.; Harting, George C.; Johnson, David K.; Serin, Nadir
The experimental study on the fundamental processes involved in fuel decomposition and boundary-layer combustion in hybrid rocket motors is continuously being conducted at the High Pressure Combustion Laboratory of The Pennsylvania State University. This research will provide a useful engineering technology base in the development of hybrid rocket motors as well as a fundamental understanding of the complex processes involved in hybrid propulsion. A high-pressure, 2-D slab motor has been designed, manufactured, and utilized for conducting seven test firings using HTPB fuel processed at PSU. A total of 20 fuel slabs have been received from the Mcdonnell Douglas Aerospace Corporation. Ten of these fuel slabs contain an array of fine-wire thermocouples for measuring solid fuel surface and subsurface temperatures. Diagnostic instrumentation used in the test include high-frequency pressure transducers for measuring static and dynamic motor pressures and fine-wire thermocouples for measuring solid fuel surface and subsurface temperatures. The ultrasonic pulse-echo technique as well as a real-time x-ray radiography system have been used to obtain independent measurements of instantaneous solid fuel regression rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L. N.
This report provides the results of analyses on Savannah River Site Tank 4 surface and subsurface supernatant liquid samples in support of the Enrichment Control Program (ECP), the Corrosion Control Program (CCP) and the Evaporator Feed Qualification (EFQ) Program. The purpose of the ECP sample taken from Tank 4 in August 2015 was to determine if the supernatant liquid would be “acceptable feed” to the 2H and 3H evaporator systems.
Improving Long-term Post-wildfire hydrologic simulations using ParFlow
NASA Astrophysics Data System (ADS)
Lopez, S. R.; Kinoshita, A. M.
2015-12-01
Wildfires alter the natural hydrologic processes within a watershed. After vegetation is burned, the combustion of organic material and debris settles into the soil creating a hydrophobic layer beneath the soil surface with varying degree of thickness and depth. Vegetation regrowth rates vary as a function of radiative exposure, burn severity, and precipitation patterns. Hydrologic models used by the Burned Area Emergency Response (BAER) teams use input data and model calibration constraints that are generally either one-dimensional, empirically-based models, or two-dimensional, conceptually-based models with lumped parameter distributions. These models estimate runoff measurements at the watershed outlet; however, do not provide a distributed hydrologic simulation at each point within the watershed. This work uses ParFlow, a three-dimensional, distributed hydrologic model to (1) correlate burn severity with hydrophobicity, (2) evaluate vegetation recovery rate on water components, and (3) improve flood prediction for managers to help with resource allocation and management operations in burned watersheds. ParFlow is applied to Devil Canyon (43 km2) in San Bernardino, California, which was 97% burned in the 2003 Old Fire. The model set-up uses a 30m-cell size resolution over a 6.7 km by 6.4 km lateral extent. The subsurface reaches 30 m and is assigned a variable cell thickness. Variable subsurface thickness allows users to explicitly consider the degree of recovery throughout the stages of regrowth. Burn severity maps from remotely sensed imagery are used to assign initial hydrophobic layer parameters and thickness. Vegetation regrowth is represented with satellite an Enhanced Vegetation Index. Pre and post-fire hydrologic response is evaluated using runoff measurements at the watershed outlet, and using water component (overland flow, lateral flow, baseflow) measurements.
Wildland fire limits subsequent fire occurrence
Sean A. Parks; Carol Miller; Lisa M. Holsinger; Scott Baggett; Benjamin J. Bird
2016-01-01
Several aspects of wildland fire are moderated by site- and landscape-level vegetation changes caused by previous fire, thereby creating a dynamic where one fire exerts a regulatory control on subsequent fire. For example, wildland fire has been shown to regulate the size and severity of subsequent fire. However, wildland fire has the potential to influence...
34 CFR 668.49 - Institutional fire safety policies and fire statistics.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...
34 CFR 668.49 - Institutional fire safety policies and fire statistics.
Code of Federal Regulations, 2012 CFR
2012-07-01
... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...
34 CFR 668.49 - Institutional fire safety policies and fire statistics.
Code of Federal Regulations, 2014 CFR
2014-07-01
... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...
34 CFR 668.49 - Institutional fire safety policies and fire statistics.
Code of Federal Regulations, 2013 CFR
2013-07-01
... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...
Mapping wildfire burn severity in the Arctic Tundra from downsampled MODIS data
Kolden, Crystal A.; Rogan, John
2013-01-01
Wildfires are historically infrequent in the arctic tundra, but are projected to increase with climate warming. Fire effects on tundra ecosystems are poorly understood and difficult to quantify in a remote region where a short growing season severely limits ground data collection. Remote sensing has been widely utilized to characterize wildfire regimes, but primarily from the Landsat sensor, which has limited data acquisition in the Arctic. Here, coarse-resolution remotely sensed data are assessed as a means to quantify wildfire burn severity of the 2007 Anaktuvuk River Fire in Alaska, the largest tundra wildfire ever recorded on Alaska's North Slope. Data from Landsat Thematic Mapper (TM) and downsampled Moderate-resolution Imaging Spectroradiometer (MODIS) were processed to spectral indices and correlated to observed metrics of surface, subsurface, and comprehensive burn severity. Spectral indices were strongly correlated to surface severity (maximum R2 = 0.88) and slightly less strongly correlated to substrate severity. Downsampled MODIS data showed a decrease in severity one year post-fire, corroborating rapid vegetation regeneration observed on the burned site. These results indicate that widely-used spectral indices and downsampled coarse-resolution data provide a reasonable supplement to often-limited ground data collection for analysis and long-term monitoring of wildfire effects in arctic ecosystems.
A Drought Index for Forest Fire Control
John J. Keetch; George M. Byram
1968-01-01
The moisture content of the upper soil, as well as that of the covering layer of duff, has an important effect on the fire suppression effort in forest and wildland areas. In certain forested areas of the United States, fires in deep duff fuels are of particular concern to the fire control manager. When these fuels are dry, fires burn deeply, dam-age is excessive, and...
Code of Federal Regulations, 2013 CFR
2013-07-01
... installed: (a) Cutting paraffin; (b) Removing and setting pump-through-type tubing plugs, gas-lift valves...) Corrosion inhibitor treatment; (i) Removing or replacing subsurface pumps; (j) Through-tubing logging (diagnostics); (k) Wireline fishing; and (l) Setting and retrieving other subsurface flow-control devices...
Code of Federal Regulations, 2014 CFR
2014-07-01
... installed: (a) Cutting paraffin; (b) Removing and setting pump-through-type tubing plugs, gas-lift valves...) Corrosion inhibitor treatment; (i) Removing or replacing subsurface pumps; (j) Through-tubing logging (diagnostics); (k) Wireline fishing; and (l) Setting and retrieving other subsurface flow-control devices...
Code of Federal Regulations, 2012 CFR
2012-07-01
... installed: (a) Cutting paraffin; (b) Removing and setting pump-through-type tubing plugs, gas-lift valves...) Corrosion inhibitor treatment; (i) Removing or replacing subsurface pumps; (j) Through-tubing logging (diagnostics); (k) Wireline fishing; and (l) Setting and retrieving other subsurface flow-control devices...
Natural attenuation remediation is based on the intrinsic attenuation capacities of the subsurface. Geochemistry of the subsurface controls the fate, transport, transformation, and bioavailability of contaminants. This paper demonstrates that interfacial reactions (e.g., adsorp...
36 CFR 211.4 - Cooperation for fire prevention and control.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Cooperation for fire... AGRICULTURE ADMINISTRATION Cooperation § 211.4 Cooperation for fire prevention and control. The Forest Service... will result in mutual benefit in the prevention and suppression of forest fires: Provided, That the...
36 CFR 211.4 - Cooperation for fire prevention and control.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 2 2011-07-01 2011-07-01 false Cooperation for fire... AGRICULTURE ADMINISTRATION Cooperation § 211.4 Cooperation for fire prevention and control. The Forest Service... will result in mutual benefit in the prevention and suppression of forest fires: Provided, That the...
Stottlemyer, R.; Troendle, C.A.
1999-01-01
Research on the effects of vegetation manipulation on snowpack, soil water, and streamwater chemistry and flux has been underway at the Fraser Experimental Forest (FEF), CO, since 1982. Greater than 95% of FEF snowmelt passes through watersheds as subsurface flow where soil processes significantly alter meltwater chemistry. To better understand the mechanisms accounting for annual variation in watershed streamwater ion concentration and flux with snowmelt, we studied subsurface water flow, its ion concentration, and flux in conterminous forested and clear cut plots. Repetitive patterns in subsurface flow and chemistry were apparent. Control plot subsurface flow chemistry had the highest ion concentrations in late winter and fall. When shallow subsurface flow occurred, its Ca2+, SO42-, and HCO3- concentrations were lower and K+ higher than deep flow. The percentage of Ca2+, NO3-, SO42-, and HCO3- flux in shallow depths was less and K+ slightly greater than the percentage of total flow. Canopy removal increased precipitation reaching the forest floor by about 40%, increased peak snowpack water equivalent (SWE) > 35%, increased the average snowpack Ca2+, NO3-, and NH4+ content, reduced the snowpack K+ content, and increased the runoff four-fold. Clear cutting doubled the percentage of subsurface flow at shallow depths, and increased K+ concentration in shallow subsurface flow and NO3- concentrations in both shallow and deep flow. The percentage change in total Ca2+, SO42-, and HCO3- flux in shallow depths was less than the change in water flux, while that of K+ and NO3- flux was greater. Relative to the control, in the clear cut the percentage of total Ca2+ flux at shallow depths increased from 5 to 12%, SO42- 5.4 to 12%, HCO3- from 5.6 to 8.7%, K+ from 6 to 35%, and NO3- from 2.7 to 17%. The increases in Ca2+ and SO42- flux were proportional to the increase in water flux, the flux of HCO3- increased proportionally less than water flux, and NO3- and K+ were proportionally greater than water flux. Increased subsurface flow accounted for most of the increase in non-limiting nutrient loss. For limiting nutrients, loss of plant uptake and increased shallow subsurface flow accounted for the greater loss. Seasonal ion concentration patterns in streamwater and subsurface flow were similar.Research on the effects of vegetation manipulation on snowpack, soil water, and streamwater chemistry and flux has been underway at the Fraser Experimental Forest (FEF), CO, since 1982. Greater than 95% of FEF snowmelt passes through watersheds as subsurface flow where soil processes significantly alter meltwater chemistry. To better understand the mechanisms accounting for annual variation in watershed streamwater ion concentration and flux with snowmelt, we studied subsurface water flow, its ion concentration, and flux in conterminous forested and clear cut plots. Repetitive patterns in subsurface flow and chemistry were apparent. Control plot subsurface flow chemistry had the highest ion concentrations in late winter and fall. When shallow subsurface flow occurred, its Ca2+, SO42-, and HCO3- concentrations were lower and K+ higher than deep flow. The percentage of Ca2+, NO3-, SO42-, and HCO3- flux in shallow depths was less and K+ slightly greater than the percentage of total flow. Canopy removal increased precipitation reaching the forest floor by about 40%, increased peak snowpack water equivalent (SWE) > 35%, increased the average snowpack Ca2+, NO3-, and NH4+ content, reduced the snowpack K+ content, and increased the runoff four-fold. Clear cutting doubled the percentage of subsurface flow at shallow depths, and increased K+ concentration in shallow subsurface flow and NO3- concentrations in both shallow and deep flow. The percentage change in total Ca2+, SO42-, and HCO3- flux in shallow depths was less than the change in water flux, while that of K+ and NO3- flux was greater. Relative to the control, in the clear cut the percentage of total Ca
Hinojosa, M Belén; Parra, Antonio; Laudicina, Vito Armando; Moreno, José M
2016-12-15
Fire may cause significant alterations in soil properties. Post-fire soil dynamics can vary depending, among other factors, on rainfall patterns. However, little is known regarding variations in response to post-fire drought. This is relevant in arid and semiarid areas with poor soils, like much of the western Mediterranean. Furthermore, climate change projections in such areas anticipate reduced precipitation and longer annual drought periods, together with an increase in fire severity and frequency. This research evaluates the effects of experimental drought after fire on soil dynamics of a Cistus-Erica shrubland (Central Spain). A replicated (n=4) field experiment was conducted in which the total rainfall and its patterns were manipulated by means of a rain-out shelters and irrigation system. The treatments were: environmental control (natural rainfall), historical control (average rainfall, 2months drought), moderate drought (25% reduction of historical control, 5months drought) and severe drought (45% reduction, 7months drought). After one growing season under these rainfall treatments, the plots were burned. One set of unburned plots under natural rainfall served as an additional control. Soils were collected seasonally. Fire increased soil P and N availability. Post-fire drought treatments reduced available soil P but increased N concentration (mainly nitrate). Fire reduced available K irrespective of drought treatments. Fire reduced enzyme activities and carbon mineralization rate, a reduction that was higher in post-fire drought-treated soils. Fire decreased soil microbial biomass and the proportion of fungi, while that of actinomycetes increased. Post-fire drought decreased soil total microbial biomass and fungi, with bacteria becoming more abundant. Our results support that increasing drought after fire could compromise the resilience of Mediterranean ecosystems to fire. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pudasainee, Deepak; Kim, Jeong-Hun; Seo, Yong-Chil
2009-12-01
Regulatory control of mercury emission from anthropogenic sources has become a global concern in the recent past. Coal-fired power plants are one of the largest sources of anthropogenic mercury emission into the atmosphere. This paper summarizes the current reducing trend of mercury emission as co-beneficial effect by more stringent regulation changes to control primary air pollutants with introducing test results from the commercial coal-fired facilities and suggesting a guideline for future regulatory development in Korea. On average, mercury emission concentrations ranged 16.3-2.7 μg Sm -3, 2.4-1.1 μg Sm -3, 3.1-0.7 μg Sm -3 from anthracite coal-fired power plants equipped with electrostatic precipitator (ESP), bituminous coal-fired power plants with ESP + flue gas desulphurization (FGD) and bituminous coal-fired power plants with selective catalytic reactor (SCR) + cold side (CS) - ESP + wet FGD, respectively. Among the existing air pollution control devices, the best configuration for mercury removal in coal-fired power plants was SCR + CS - ESP + wet FGD, which were installed due to the stringent regulation changes to control primary air pollutants emission such as SO 2, NOx and dust. It was estimated that uncontrolled and controlled mercury emission from coal-fired power plants as 10.3 ton yr -1 and 3.2 ton yr -1 respectively. After the installation of ESP, FGD and SCR system, following the enforcement of the stringent regulation, 7.1 ton yr -1 of mercury emission has been reduced (nearly 69%) from coal-fired power plants as a co-benefit control. Based on the overall study, a sample guideline including emission limits were suggested which will be applied to develop a countermeasure for controlling mercury emission from coal-fired power plants.
Parks, Sean A; Holsinger, Lisa M; Miller, Carol; Nelson, Cara R
2015-09-01
Theory suggests that natural fire regimes can result in landscapes that are both self-regulating and resilient to fire. For example, because fires consume fuel, they may create barriers to the spread of future fires, thereby regulating fire size. Top-down controls such as weather, however, can weaken this effect. While empirical examples demonstrating this pattern-process feedback between vegetation and fire exist, they have been geographically limited or did not consider the influence of time between fires and weather. The availability of remotely sensed data identifying fire activity over the last four decades provides an opportunity to explicitly quantify-the ability of wildland fire to limit the progression of subsequent fire. Furthermore, advances in fire progression mapping now allow an evaluation of how daily weather as a top-down control modifies this effect. In this study, we evaluated the ability of wildland fire to create barriers that limit the spread of subsequent fire along a gradient representing time between fires in four large study areas in the western United States. Using fire progression maps in conjunction with weather station data, we also evaluated the influence of daily weather. Results indicate that wildland fire does limit subsequent fire spread in all four study areas, but this effect decays over time; wildland fire no longer limits subsequent fire spread 6-18 years after fire, depending on the study area. We also found that the ability of fire to regulate, subsequent fire progression was substantially reduced under extreme conditions compared to moderate weather conditions in all four study areas. This study increases understanding of the spatial feedbacks that can lead to self-regulating landscapes as well as the effects of top-down controls, such as weather, on these feedbacks. Our results will be useful to managers who seek to restore natural fire regimes or to exploit recent burns when managing fire.
Tran, Anh Phuong; Dafflon, Baptiste; Hubbard, Susan S.; ...
2016-04-25
Improving our ability to estimate the parameters that control water and heat fluxes in the shallow subsurface is particularly important due to their strong control on recharge, evaporation and biogeochemical processes. The objectives of this study are to develop and test a new inversion scheme to simultaneously estimate subsurface hydrological, thermal and petrophysical parameters using hydrological, thermal and electrical resistivity tomography (ERT) data. The inversion scheme-which is based on a nonisothermal, multiphase hydrological model-provides the desired subsurface property estimates in high spatiotemporal resolution. A particularly novel aspect of the inversion scheme is the explicit incorporation of the dependence of themore » subsurface electrical resistivity on both moisture and temperature. The scheme was applied to synthetic case studies, as well as to real datasets that were autonomously collected at a biogeochemical field study site in Rifle, Colorado. At the Rifle site, the coupled hydrological-thermal-geophysical inversion approach well predicted the matric potential, temperature and apparent resistivity with the Nash-Sutcliffe efficiency criterion greater than 0.92. Synthetic studies found that neglecting the subsurface temperature variability, and its effect on the electrical resistivity in the hydrogeophysical inversion, may lead to an incorrect estimation of the hydrological parameters. The approach is expected to be especially useful for the increasing number of studies that are taking advantage of autonomously collected ERT and soil measurements to explore complex terrestrial system dynamics.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L. N.
2015-02-18
The 2H Evaporator system includes mainly Tank 43H (feed tank) and Tank 38H (drop tank) with Tank 22H acting as the DWPF recycle receipt tank. The Tank 13H is being characterized to ensure that it can be transferred to the 2H evaporator. This report provides the results of analyses on Tanks 13H surface and subsurface supernatant liquid samples to ensure compliance with the Enrichment Control Program (ECP), the Corrosion Control Program and Sodium Aluminosilicate Formation Potential in the Evaporator. The U-235 mass divided by the total uranium averaged 0.00799 (0.799 % uranium enrichment) for both the surface and subsurface Tankmore » 13H samples. This enrichment is slightly above the enrichment for Tanks 38H and 43H, where the enrichment normally ranges from 0.59 to 0.7 wt%. The U-235 concentration in Tank 13H samples ranged from 2.01E-02 to 2.63E-02 mg/L, while the U-238 concentration in Tank 13H ranged from 2.47E+00 to 3.21E+00 mg/L. Thus, the U-235/total uranium ratio is in line with the prior 2H-evaporator ECP samples. Measured sodium and silicon concentrations averaged, respectively, 2.46 M and 1.42E-04 M (3.98 mg/L) in the Tank 13H subsurface sample. The measured aluminum concentration in Tanks 13H subsurface samples averaged 2.01E-01 M.« less
COUPLED GEOPHYSICAL-HYDROLOGICAL MODELING OF A CONTROLLED NAPL SPILL
Past studies have shown reasonable sensitivity of geophysical data for detecting or monitoring the movement of non-aqueous phase liquids (NAPLs) in the subsurface. However, heterogeneity in subsurface properties and in NAPL distribution commonly results in non-unique data
...
Measurements of forest fire danger
Leo Shames
1938-01-01
Although the annual destruction of life and property attributable to forest fires is enormous, scientific methods of forest fire control in the United States are of comparatively recent origin. In one important phase of control, that of determining how large a network of observers is necessary for the purpose of discovering forest fires in their infancy, accurate means...
Can Southern California Wildland Conflagrations be Stopped?
Clive M. Countryman
1974-01-01
In southern California, many fires start and burn under conditions that permit their control with little burned acreage and fire damage. In contrast, under other conditions of weather and topography, on a small group of fires, control effort is relatively ineffective; they become large and destructive. A major reason for these "conflagration fires" is the...
Spatiotemporal variability of wildland fuels in US Northern Rocky Mountain forests
Robert E. Keane
2016-01-01
Fire regimes are ultimately controlled by wildland fuel dynamics over space and time; spatial distributions of fuel influence the size, spread, and intensity of individual fires, while the temporal distribution of fuel deposition influences fire's frequency and controls fire size. These "shifting fuel mosaics" are both a cause and a consequence...
Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.
ERIC Educational Resources Information Center
Department of Education and Science, London (England).
This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…
Strategy for increasing the participation of masyarakat peduli api in forest fire control
NASA Astrophysics Data System (ADS)
Ni’mah, N. L. K.; Herdiansyah, H.; Soesilo, T. E. B.; Mutia, E. F.
2018-03-01
Forest fires have negative impact on ecology, health, and damage economic activities. One of conservation areas facing the threat of forest fire is Gunung Ciremai National Park. This research aims to formulate a strategy to increase the participation of Masyarakat Peduli Api in the effort of forest fire control. This research use quantitative method with SWOT analysis. Expert consisting of representatives from the national park, Ministry of Environment and Forestry, and BPBD Kuningan Regency. An alternative strategy based on SWOT analysis is in quadrant 1 with coordinate point (0,39; 1,23). The position shows that sustainability of national park management through forest fire control can be done with an aggressive strategy. That is maximizing the strength that is owned with its potential as an ecotourism area to increase community motivation to engage in forest fire control activities. Provision of tourism management licenses will create employment opportunities and increase income for the community so it is expected to increase community participation to prevent the occurrence of forest fires rather than forest fire prevention.
NASA Astrophysics Data System (ADS)
Riebe, C. S.; Callahan, R. P.; Goulden, M.; Pasquet, S.; Flinchum, B. A.; Taylor, N. J.; Holbrook, W. S.
2017-12-01
The availability of water and nutrients in soil and weathered rock influences the distribution of Earth's terrestrial life and regulates ecosystem vulnerability to land use and climate change. We explored these relationships by combining geochemical and geophysical measurements at three mid-elevation sites in the Sierra Nevada, California. Forest cover correlates strongly with bedrock composition across the sites, implying strong lithologic control on the ecosystem. We evaluated two hypotheses about bedrock-ecosystem connections: 1) that bedrock composition influences vegetation by moderating plant-essential nutrient supply; and 2) that bedrock composition influences the degree of subsurface weathering, which influences vegetation by controlling subsurface water-storage capacity. To quantify subsurface water-holding capacity, we used seismic refraction surveys to infer gradients in P and S-wave velocity structure, which reveal variations in porosity when coupled together in a Hertz-Mindlin rock-physics model. We combined the geophysical data on porosity with bedrock bulk geochemistry measured in previous work to evaluate the influence of water-holding capacity and nutrient supply on ecosystem productivity, which we quantified using remote sensing. Our results show that more than 80% of the variance in ecosystem productivity can be explained by differences in bedrock phosphorus concentration and subsurface porosity, with phosphorus content being the dominant explanatory variable. This suggests that bedrock composition exerts a strong bottom-up control on ecosystem productivity through its influence on nutrient supply and weathering susceptibility, which in turn influences porosity. We show that vegetation vulnerability to drought stress and mortality can be explained in part by variations in subsurface water-holding capacity and rock-derived nutrient supply.
NASA Astrophysics Data System (ADS)
Chang, Chun-Hung; Wilson, Christopher R.; Fried, Nathaniel M.
2015-07-01
Lasers have been used in combination with applied cooling methods to preserve superficial skin layers (100's μm's) during cosmetic surgery. Preservation of a thicker tissue surface layer (millimeters) may also allow development of other noninvasive laser procedures. We are exploring noninvasive therapeutic laser applications in urology (e.g. laser vasectomy and laser treatment of female stress urinary incontinence), which require surface tissue preservation on the millimeter scale. In this preliminary study, four lasers were compared for noninvasive creation of deep subsurface thermal lesions. Laser energy from three diode lasers (650, 808, and 980 nm) and a Ytterbium fiber laser (1075 nm) was delivered through a custom built, side-firing, laser probe with integrated cooling. An alcohol-based solution at -5 °C was circulated through a flow cell, cooling a sapphire window, which in turn cooled the tissue surface. The probe was placed in contact with porcine liver tissue, ex vivo, kept hydrated in saline and maintained at ~ 35 °C. Incident laser power was 4.2 W, spot diameter was 5.3 mm, and treatment time was 60 s. The optimal laser wavelength tested for creation of deep subsurface thermal lesions during contact cooling of tissues was 1075 nm, which preserved a surface layer of ~ 2 mm. The Ytterbium fiber laser provides a compact, low maintenance, and high power alternative laser source to the Neodymium:YAG laser for noninvasive thermal therapy.
Code of Federal Regulations, 2014 CFR
2014-10-01
... place where the remote fire pump control is located. (c) The fire main must have a sufficient number of... 46 Shipping 1 2014-10-01 2014-10-01 false What are the requirements for fire pumps, fire mains... the requirements for fire pumps, fire mains, and fire hoses on towing vessels? By April 29, 2005, you...
Empirical evidence for multi-scaled controls on wildfire size distributions in California
NASA Astrophysics Data System (ADS)
Povak, N.; Hessburg, P. F., Sr.; Salter, R. B.
2014-12-01
Ecological theory asserts that regional wildfire size distributions are examples of self-organized critical (SOC) systems. Controls on SOC event-size distributions by virtue are purely endogenous to the system and include the (1) frequency and pattern of ignitions, (2) distribution and size of prior fires, and (3) lagged successional patterns after fires. However, recent work has shown that the largest wildfires often result from extreme climatic events, and that patterns of vegetation and topography may help constrain local fire spread, calling into question the SOC model's simplicity. Using an atlas of >12,000 California wildfires (1950-2012) and maximum likelihood estimation (MLE), we fit four different power-law models and broken-stick regressions to fire-size distributions across 16 Bailey's ecoregions. Comparisons among empirical fire size distributions across ecoregions indicated that most ecoregion's fire-size distributions were significantly different, suggesting that broad-scale top-down controls differed among ecoregions. One-parameter power-law models consistently fit a middle range of fire sizes (~100 to 10000 ha) across most ecoregions, but did not fit to larger and smaller fire sizes. We fit the same four power-law models to patch size distributions of aspect, slope, and curvature topographies and found that the power-law models fit to a similar middle range of topography patch sizes. These results suggested that empirical evidence may exist for topographic controls on fire sizes. To test this, we used neutral landscape modeling techniques to determine if observed fire edges corresponded with aspect breaks more often than expected by random. We found significant differences between the empirical and neutral models for some ecoregions, particularly within the middle range of fire sizes. Our results, combined with other recent work, suggest that controls on ecoregional fire size distributions are multi-scaled and likely are not purely SOC. California wildfire ecosystems appear to be adaptive, governed by stationary and non-stationary controls, which may be either exogenous or endogenous to the system.
Fire and aquatic ecosystems of the western USA: Current knowledge and key questions
Bisson, P.A.; Rieman, B.; Luce, C.; Hessburg, Paul F.; Lee, D.; Kershner, J.; Reeves, G.H.; Gresswell, Robert E.
2003-01-01
Understanding of the effects of wildland fire and fire management on aquatic and riparian ecosystems is an evolving field, with many questions still to be resolved. Limitations of current knowledge, and the certainty that fire management will continue, underscore the need to summarize available information. Integrating fire and fuels management with aquatic ecosystem conservation begins with recognizing that terrestrial and aquatic ecosystems are linked and dynamic, and that fire can play a critical role in maintaining aquatic ecological diversity. To protect aquatic ecosystems we argue that it will be important to: (1) accommodate fire-related and other ecological processes that maintain aquatic habitats and biodiversity, and not simply control fires or fuels; (2) prioritize projects according to risks and opportunities for fire control and the protection of aquatic ecosystems; and (3) develop new consistency in the management and regulatory process. Ultimately, all natural resource management is uncertain; the role of science is to apply experimental design and hypothesis testing to management applications that affect fire and aquatic ecosystems. Policy-makers and the public will benefit from an expanded appreciation of fire ecology that enables them to implement watershed management projects as experiments with hypothesized outcomes, adequate controls, and replication.
2007 Ikhana Western States and Southern California Emergency UAS Fire Missions
NASA Technical Reports Server (NTRS)
Cobleigh, Brent
2008-01-01
Four demonstration and four emergency fire imaging missions completed: a) Thermal infrared imagery delivered in near real-time (5 to 15 minutes) to: 1) SoCal Emergency: FEMA, NIFC, NorthCom, California EOC; 2) Demo Flights: NIFC, Individual Fire Incident Commands. Imagery used for tactical and strategic decision making. Air Traffic Control gave excellent support. Mission plans flown in reverse. Real time requests for revisits of active fires. Added new fire during mission. Moved fire loiter points as fires moved. Real-time reroute around thunderstorm activity. Pre & Post flight telecons with FAA were held to review mission and discuss operational improvements. No issues with air traffic control during the 8 fire missions flown.
Climatic and human controls on the late Holocene fire history of northern Israel
NASA Astrophysics Data System (ADS)
Quintana Krupinski, N. B.; Nishri, A.; Street, J. H.; Paytan, A.
2011-12-01
Long-term fire histories provide insight into the effects of climate, ecology and human influence on fire activity. Fire records can be expanded beyond the period of historical record using accumulation rates of large charcoal particles and soot black carbon (BC) in lacustrine sediments: charcoal accumulation peaks indicate local to regional fire events, while increased deposition of BC may document regional-scale burning. To determine which factors exert the greatest control over changes in fire frequency at different times, this study compares late Holocene fire records from Lake Kinneret (the Sea of Galilee), Israel to local and regional records of climate and human activity. We show that fire frequency decreased during the past 3010 years from 3-4 fire events per 400 years between 3010 - 2620 y.b.p. to 0-2 fire events per 400 years from 750 y.b.p. to present. Human modification of the landscape during periods of high population (e.g. forest clearing, agriculture, settlement expansion and industry) appears to have been the greatest contributor to increased fire activity in the semi-arid southern Levant region during the late Holocene, though aridity may also have contributed to higher fire activity. However, during much of the study period, climate and human activity were interrelated, so while human activity may have been the greater control on fire activity, the effect of climate may have been both direct and indirect (through climate-related changes in population), making it sometimes difficult to distinguish the two controls. Projections of increasing aridification of the region combined with a heavy impact on the landscape from a large modern population suggest that increased fire activity may occur in the region in the near future.
36 CFR 228.11 - Prevention and control of fire.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Prevention and control of fire. 228.11 Section 228.11 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF AGRICULTURE MINERALS Locatable Minerals § 228.11 Prevention and control of fire. Operator shall comply with...
36 CFR 228.11 - Prevention and control of fire.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 2 2011-07-01 2011-07-01 false Prevention and control of fire. 228.11 Section 228.11 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF AGRICULTURE MINERALS Locatable Minerals § 228.11 Prevention and control of fire. Operator shall comply with...
Installation Restoration Program. Phase 1. Records Search, Kelly AFB, Texas
1982-02-01
1000-1500 gallons per year based on two training sessions per year. The ultimate BOD of AFFF ( FC -780B, manufactured by 3M) is 370,000 mg/l in...Landfill 1917-1942 44 24 FC -i Fire Control Training Area ?-1950’s 42 25 FC -2 Fire Control Training Area 1950’s-1981 41 26 RD-i Radioactive Disposal Area...were buried had very short half-lifes. This site received a low score of 45. 6) Fire Control Training Areas a. The Fire Control Training Areas FC -I and
Scanlon, Todd M.; Raffensperger, Jeff P.; Hornberger, George M.; Clapp, Roger B.
2000-01-01
Transient, perched water tables in the shallow subsurface are observed at the South Fork Brokenback Run catchment in Shenandoah National Park, Virginia. Crest piezometers installed along a hillslope transect show that the development of saturated conditions in the upper 1.5 m of the subsurface is controlled by total precipitation and antecedent conditions, not precipitation intensity, although soil heterogeneities strongly influence local response. The macroporous subsurface storm flow zone provides a hydrological pathway for rapid runoff generation apart from the underlying groundwater zone, a conceptualization supported by the two‐storage system exhibited by hydrograph recession analysis. A modified version of TOPMODEL is used to simulate the observed catchment dynamics. In this model, generalized topographic index theory is applied to the subsurface storm flow zone to account for logarithmic storm flow recessions, indicative of linearly decreasing transmissivity with depth. Vertical drainage to the groundwater zone is required, and both subsurface reservoirs are considered to contribute to surface saturation.
Fractal topography and subsurface water flows from fluvial bedforms to the continental shield
Worman, A.; Packman, A.I.; Marklund, L.; Harvey, J.W.; Stone, S.H.
2007-01-01
Surface-subsurface flow interactions are critical to a wide range of geochemical and ecological processes and to the fate of contaminants in freshwater environments. Fractal scaling relationships have been found in distributions of both land surface topography and solute efflux from watersheds, but the linkage between those observations has not been realized. We show that the fractal nature of the land surface in fluvial and glacial systems produces fractal distributions of recharge, discharge, and associated subsurface flow patterns. Interfacial flux tends to be dominated by small-scale features while the flux through deeper subsurface flow paths tends to be controlled by larger-scale features. This scaling behavior holds at all scales, from small fluvial bedforms (tens of centimeters) to the continental landscape (hundreds of kilometers). The fractal nature of surface-subsurface water fluxes yields a single scale-independent distribution of subsurface water residence times for both near-surface fluvial systems and deeper hydrogeological flows. Copyright 2007 by the American Geophysical Union.
Fire protection review revisit no. 2, Argonne National Laboratory, Argonne, Illinois
NASA Astrophysics Data System (ADS)
Dobson, P. H.; Earley, M. W.; Mattern, L. J.
1985-05-01
A fire protection survey was conducted at Argonne National Laboratory on April 1-5, 8-12, and April 29-May 2, 1985. The purpose was to review the facility fire protection program and to make recommendations or identify areas according to criteria established by the Department of Energy. There has been a substantial improvement in fire protection at this laboratory since the 1977 audit. Numerous areas which were previously provided with detection systems only have since been provided with automatic sprinkler protection. The following basic fire protection features are not properly controlled: (1) resealing wall and floor penetrations between fire areas after installation of services; (2) cutting and welding; and (3) housekeeping. The present Fire Department manpower level appears adequate to control a route fire. Their ability to adequately handle a high-challenge fire, or one involving injuries to personnel, or fire spread beyond the initial fire area is doubtful.
RESEARCH ACTIVITIES AT U.S. GOVERNMENT AGENCIES IN SUBSURFACE REACTIVE TRANSPORT MODELING
The fate of contaminants in the environment is controlled by both chemical reactions and transport phenomena in the subsurface. Our ability to understand the significance of these processes over time requires an accurate conceptual model that incorporates the various mechanisms ...
NASA Astrophysics Data System (ADS)
Saravanavel, J.; Ramasamy, S. M.
2014-11-01
The study area falls in the southern part of the Indian Peninsular comprising hard crystalline rocks of Archaeozoic and Proterozoic Era. In the present study, the GIS based 3D visualizations of gravity, magnetic, resistivity and topographic datasets were made and therefrom the basement lineaments, shallow subsurface lineaments and surface lineaments/faults were interpreted. These lineaments were classified as category-1 i.e. exclusively surface lineaments, category-2 i.e. surface lineaments having connectivity with shallow subsurface lineaments and category-3 i.e. surface lineaments having connectivity with shallow subsurface lineaments and basement lineaments. These three classified lineaments were analyzed in conjunction with known mineral occurrences and historical seismicity of the study area in GIS environment. The study revealed that the category-3 NNE-SSW to NE-SW lineaments have greater control over the mineral occurrences and the N-S, NNE-SSW and NE-SW, faults/lineaments control the seismicities in the study area.
46 CFR 62.35-15 - Fire safety.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...
46 CFR 62.35-15 - Fire safety.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...
46 CFR 62.35-15 - Fire safety.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...
Thermal surface characteristics of coal fires 1 results of in-situ measurements
NASA Astrophysics Data System (ADS)
Zhang, Jianzhong; Kuenzer, Claudia
2007-12-01
Natural underground coal fires are fires in coal seams occurring subsurface. The fires are ignited through a process named spontaneous combustion, which occurs based on a natural reaction but is usually triggered through human interaction. Coal mining activities expose coal to the air. This leads to the exothermal oxidation of the carbon in the coal with the air's oxygen to CO 2 and - under certain circumstances - to spontaneous combustion. Coal fires occur in many countries world wide - however, currently the Chinese coal mining industry faces the biggest problems with coal fires. Coal fires destroy the valuable resource coal and furthermore lead to many environmental degradation phenomena such as the deterioration of surrounding vegetation, land subsidence and the emission of toxic gasses (CO, N 2O). They additionally contribute to the emission of green house relevant gasses such as CO 2 and CH 4 to the atmosphere. In this paper we present thermal characteristics of coal fires as measured in-situ during a field campaign to the Wuda coal fire area in south-central Inner Mongolia, China. Thermal characteristics include temperature anomaly measurements at the surface, spatial surface temperature profiles of fire areas and unaffected background areas, diurnal temperature profiles, and temperature measurements inside of coal fire induced cracks in the overlying bedrock. For all the measurements the effects of uneven solar heating through influences of slope and aspect are considered. Our findings show that coal fires result in strong or subtle thermal surface anomalies. Especially the latter can easily be influenced by heating of the surrounding background material through solar influences. Temperature variation of background rocks with different albedo, slope, aspect or vegetation cover can substantially influence the detectability of thermal anomalies. In the worst case coal fire related thermal anomalies can be completely masked by solar patterns during the daytime. Thus, night-time analysis is the most suitable for thermal anomaly mapping of underground coal fires, although this is not always feasible. The heat of underground coal fires only progresses very slowly through conduction in the rock material. Anomalies of coal fires completely covered by solid unfractured bedrock are very weak and were only measured during the night. The thermal pattern of underground coal fires manifested on the surface during the daytime is thus the pattern of cracks and vents, which occur due to the volume loss underground and which support radiation and convective energy transport of hot gasses. Inside coal fire temperatures can hardly be measured and can only be recorded if the glowing coal is exposed through a wider crack in the overlaying bedrock. Direct coal fire temperatures measured ranged between 233 °C and 854 °C. The results presented can substantially support the planning of thermal mapping campaigns, analyses of coal fire thermal anomalies in remotely sensed data, and can provide initial and boundary conditions for coal fire related numerical modeling. In a second paper named "Thermal Characteristics of Coal Fires 2: results of measurements on simulated coal fires" [ Zhang J., Kuenzer C., Tetzlaff A., Oettl D., Zhukov B., Wagner W., 2007. Thermal Characteristics of Coal Fires 2: Result of measurements on simulated coal fires. Accepted for publication at Journal of Applied Geophysics. doi:10.1016/j.jappgeo.2007.08.003] we report about thermal characteristics of simulated coal fires simulated under simplified conditions. The simulated set up allowed us to measure even more parameters under undisturbed conditions — especially inside fire temperatures. Furthermore we could demonstrate the differences between open surface coal fires and covered underground coal fires. Thermal signals of coal fires in near range thermal remotely sensed imagery from an observing tower and from an airplane are presented and discussed.
NASA Astrophysics Data System (ADS)
Zhang, Z. Fred
2016-06-01
A surface barrier is a commonly used technology for isolation of subsurface contaminants. Surface barriers for isolating radioactive waste are expected to perform for centuries to millennia, yet there are very few data for field-scale surface barriers for periods approaching a decade or longer. The Prototype Hanford Barrier (PHB) with a design life of 1000 years was constructed over an existing radioactive waste site in 1994 to demonstrate its long-term performance. The primary element of the PHB is an evapotranspiration-capillary (ETC) barrier in which precipitation water is stored in a fine-textured soil layer and later released to the atmosphere via evapotranspiration. To address the barrier performance under extreme conditions, this study included an enhanced precipitation stress test from 1995 to 1997 to determine barrier response to extreme precipitation events. During this period a 1000 year 24 h return rainstorm was simulated in March every year. The loss of vegetation on barrier hydrology was tested with a controlled fire test in 2008. The 19 year monitoring record shows that the store-and-release mechanism worked as well as or better than the design criterion. Average drainage from the ETC barrier amounted to an average of 0.005 mm yr-1, which is well below the design criterion of 0.5 mm yr-1. After a simulated wildfire, the naturally reestablished vegetation and increased evaporation combined to release the stored water and summer precipitation to the atmosphere such that drainage did not occur in the 5 years subsequent to the fire.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwager, K.; Green, T. M.
The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened,more » and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.« less
Al-Karadaghi, Tamara Sardar; Gutknecht, Norbert; Jawad, Hussein A; Vanweersch, Leon; Franzen, Rene
2015-09-01
The purpose of this study was to evaluate the effects of dual wavelength (2780 nm Er,Cr:YSGG and 940 nm diode) laser with radial firing tip (RFT) on the external root surface and sub-surfaces, in terms of temperature changes during laser-assisted root canal treatment. A significant factor that may limit the use of lasers in endodontics is the possible thermal injury to tooth supporting structures. A total of 50 sound single-rooted extracted teeth were divided randomly into two groups (n = 25). Group A, irradiated with Er,Cr:YSGG laser at 1.06 W, 50 Hz, and 50 μs was a control group, and group B was irradiated with dual wavelength of Er,Cr:YSGG laser with the same settings as group A and a diode laser of 0.51 W at 4 ms and 10 ms pulse duration. K-type thermocouples were used to record temperature changes at the cervical, middle, and apical root thirds, on root surfaces and sub-surfaces, arising from delivery of laser energy through RFT. Temperature elevation in group B was significantly higher in the middle and apical thirds of the prepared samples than in group A (p < 0.0001). Group B presented a mean temperature elevation of 5.07°C on the apical surface region corresponding to a 1.48 mm dentin thickness, whereas a mean temperature increase of 7.72°C was recorded corresponding to dentin thickness of 0.95 mm. Within the studied parameters, the dual wavelength laser did not result in adverse thermal changes on the external root surface in vitro.
Rynne, Timothy M.; Spadaro, John F.; Iovenitti, Joe L.; Dering, John P.; Hill, Donald G.
1998-10-27
A method of enhancing the remediation of contaminated soils and ground water, production of oil and gas, and production of any solid, gas, and/or liquid from subsurface geologic and man-made formations including the steps of estimating the geometric boundaries of the region containing the material to be recovered, drilling a recovery well(s) into subsurface in a strategic location to recover the material of interest, establishing multiple sources of acoustical power in an array about and spaced-apart from the surface or at various depths below the surface in a borehole(s) and/or well(s), directing a volume of acoustical excitation from the sources into the region containing the material to be recovered, the excitation in the form of either controllable sinusoidal, square, pulsed, or various combinations of these three waveforms, and controlling the phasing, frequency, power, duration, and direction of these waveforms from the sources to increase and control the intensity of acoustical excitation in the region of the material to be recovered to enhance. the recovery of said material from the recovery well(s). The invention will augment any technology affecting the removal of materials from the subsurface.
46 CFR 108.421 - Location of fire pumps and associated equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... pumps and associated equipment. Each fire pump required by § 108.415, and the source of power, controls... installed to protect at least one of the fire pumps, its source of power, and controls. ... 46 Shipping 4 2011-10-01 2011-10-01 false Location of fire pumps and associated equipment. 108.421...
46 CFR 108.421 - Location of fire pumps and associated equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... pumps and associated equipment. Each fire pump required by § 108.415, and the source of power, controls... installed to protect at least one of the fire pumps, its source of power, and controls. ... 46 Shipping 4 2014-10-01 2014-10-01 false Location of fire pumps and associated equipment. 108.421...
46 CFR 108.421 - Location of fire pumps and associated equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... pumps and associated equipment. Each fire pump required by § 108.415, and the source of power, controls... installed to protect at least one of the fire pumps, its source of power, and controls. ... 46 Shipping 4 2012-10-01 2012-10-01 false Location of fire pumps and associated equipment. 108.421...
46 CFR 108.421 - Location of fire pumps and associated equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... pumps and associated equipment. Each fire pump required by § 108.415, and the source of power, controls... installed to protect at least one of the fire pumps, its source of power, and controls. ... 46 Shipping 4 2013-10-01 2013-10-01 false Location of fire pumps and associated equipment. 108.421...
Informap... a computerized information system for fire planning and fire control
Theodore G. Storey; Ross D. Carder; Ernest T. Tolin
1969-01-01
INFORMAP (Information Necessary for Optimum Resource Management and Protection) is a computerized system under development for storing, manipulating, retrieving, and displaying data for fire planning and fire control. A prototype for planning applications has been developed and tested. It is programed in Fortran IV for the IBM 7040 computer, and displays information in...
Wildland fire: Nature’s fuel treatment
Brian Cooke; Sean Parks; Carol Miller; Lisa Holsinger; Cara Nelson; Zack Holden; Scott Baggett; Benjamin Bird
2016-01-01
Every year wildland fires affect much more acreage in the United States compared to controlled burns. Like controlled burns, wildland fire can help promote biological diversity and healthy ecosystems. But despite these facts, wildland fire is not often considered as a fuel treatment in the United States. Scientists working with the U.S. Forest Serviceâs Rocky Mountain...
Illuminating the Voluminous Subsurface Structures of Old Faithful Geyser, Yellowstone National Park
NASA Astrophysics Data System (ADS)
Hurwitz, Shaul; Shelly, David R.
2017-10-01
Old Faithful geyser in Yellowstone National Park has attracted scientific research for almost a century and a half. Temperature and pressure measurements and video recordings in the geyser's conduit led to proposals of many quantitative eruption models. Nevertheless, information on the processes that initiate the geyser's eruption in the subsurface remained limited. Two new studies, specifically Wu et al. (2017) and Ward and Lin (2017), take advantage of recent developments in seismic data acquisition technology and processing methods to illuminate subsurface structures. Using a dense array of three-component nodal geophones, these studies delineate subsurface structures on a scale larger than previously realized, which exert control on the spectacular eruptions of Old Faithful geyser.
Impact of a prescribed fire on soil water repellency in a Banksia woodland (Western Australia)
NASA Astrophysics Data System (ADS)
Muñoz-Rojas, Miriam; Miller, Ben; Tangney, Ryan; Miller, Russell; González-Pérez, José A.; Jiménez-Morillo, Nicasio T.; Zavala, Lorena M.; Jordán, Antonio
2016-04-01
INTRODUCTION The Swan Coastal plain of Western Australia is dominated by fire-prone banksia woodland (Burrows and McCaw, 1990). In these areas, prescription burning is often used to reduce the risk of wildfires, by reducing available fuels (Boer et al., 2009). Little research has been conducted on the effects of prescription burning on Banksia woodlands, and, in particular, information on the impacts on soil properties and soil water repellency (SWR) is scarce. Here, we have studied the impact of fire on SWR in a Banksia woodland and monitored its evolution in the medium-term. It is expected that results are useful for management and restoration of fire-affected Banksia woodlands. METHODS An experimental fire was conducted on May 7th 2015 in Kings Park, Perth, Western Australia. The fire affected an area of 6 ha of mixed Banksia/Allocasuarina woodland under moderate fire intensity. At the time of ignition, the wind speed below the canopy was 1.2 km/h. During the prescribed burning, air temperatures were on average 20 ± 1 °C and relative humidity ranged between 45 and 55% (measured using a Kestrel portable weather station). Fuel moisture averaged 11.8% (measured using Wiltronics moisture meter) and soil moisture at 1 cm deep ranged from 0.1% to 8.6% (measured with a PR2 soil profile probe attached to a HH2 data logger). Temperatures greater than 120 °C were measured 1 cm below the soil surface using iButton temperature sensors. SWR was measured under lab conditions in oven-dry samples (48 h, 105 °C) with the water drop penetration time (WDPT) test. Soil microbial activity was determined with the 1-day CO2 test that is based on the measurement of the CO2 burst produced after moistening dry soil (Muñoz-Rojas et al., 2016). PRELIMINARY RESULTS AND DISCUSSION SWR was severe in the control (mean WDPT = 2608 s) and pre-burned areas (2722 s). One week after the prescribed fire, persistence of soil water repellency remained stable in the burned area (2402 s). In contrast, extreme SWR was observed in the burned area (3750 s). This may be explained by a reduction of water repellency by burning (Zavala et al., 2009; Jordán et al., 2014), as environmental conditions led to an increase in control areas. Although prescribed burning usually do not produce high severity fires, evidences of high severity were found, due to prolonged smouldering caused by subsurface Banksia root clusters. In some cases, this led to release of iron oxides, observed as red spots in the surface. Fire in Mediterranean and semi-arid environments has a significant effect on microbial biomass and the composition of soil microbial communities during the post-fire period, when soil nutrients become available (Bárcenas-Moreno et al., 2011; Muñoz-Rojas et al., 2016). In our study, microbial activity increased sharply in the burned area and most likely contributed to a decrease of organic hydrophobic substances in the first centimetres of the soil profile. Bárcenas-Moreno et al. (2011) observed that bacterial activity increases immediately after fire, while fungi decreased and recovered slowly. These processes may contribute to explain differences in SWR following fire, since this soil property may be influenced by fungal activity (Lozano et al., 2013). ACKNOWLEDGEMENTS This research has been partly funded by the University of Western Australia through the project "Soil water repellence in biodiverse semiarid environments: new insights and implications for ecological restoration" (UWA Research Collaboration Awards, Ref. ENV.2013.6.2-4) and the Spanish Ministry for Economy and Competitiveness through the research projects GEOFIRE (Ref. CGL2012-38655-C04-01) and POSTFIRE (Ref. CGL2013-47862-C2-1-R). REFERENCES Bárcenas-Moreno G, García-Orenes F, Mataix-Solera J, Mataix-Beneyto J, Bååth E. 2011. Soil microbial recolonisation after a fire in a Mediterranean forest. Biology and Fertility of Soils 47: 261-272. DOI: 10.1007/s00374-010-0532-2. Boer MM, Sadlet RJ, Wittkuhn RS, McCaw L, Grierson PF. 2009. Long-term impacts of prescribed burning on regional extent and incidence of wildfires - evidence from 50 years of active fire management in sw australian forests. Forest Ecology and Management 259: 132-142. DOI: 10.1016/j.foreco.2009.10.005. Burrows ND, McCaw WL. 1990. Fuel characteristics and bushfire control in banksia low woodlands in western australia. Journal of Environmental Management 31: 229-236. DOI: 10.1016/S0301-4797(05)80036-2. Jordán A, Gordillo-Rivero AJ, García-Moreno J, Zavala LM, Granged AJP, Gil J, Neto-Paixão HM. 2014. Post-fire evolution of water repellency and aggregate stability in Mediterranean calcareous soils: A 6-year study. Catena 118:115-123. DOI: 10.1016/j.catena.2014.02.001. Lozano E, Jiménez-Pinilla P, Mataix-Solera J, Arcenegui V, Bárcenas GM, González-Pérez JA, García-Orenes F, Torres MP, Mataix-Beneyto J. 2013. Biological and chemical factors controlling the patchy distribution of soil water repellency among plant species in a Mediterranean semiarid forest. Geoderma 207-208:212-220. DOI: 10.1016/j.geoderma.2013.05.021. Muñoz-Rojas M, Erickson TE, Martini D, Dixon KW, Merritt DJ. 2016. Soil physicochemical and microbiological indicators of short, medium and long term post-fire recovery in semi-arid ecosystems. Ecological Indicators 63:14-22. DOI: 10.1016/j.ecolind.2015.11.038. Zavala LM, Jordán A, Gil J, Bellinfante N, Pain C. 2009. Intact ash and charred litter reduces susceptibility to rain splash erosion post-wildfire. Earth Surface Processes and Landforms 34: 1522-1532. DOI: 10.1002/esp.1837.
Inaja Fire - 1956, Pine Hills Fire - 1967...similar, yet different
Mark J. Schroeder; Bernadine B. Taylor
1968-01-01
Two fires burned in the same area in southern California under nearly similar weather conditions, 11 years apart. Yet the Inaja fire of 1956 was much more disastrous than the Pine Hills fire of 1967. The earlier fire claimed 11 lives, and covered an area five times larger than the 1967 fire. Differences in fuels, topography, fire behavior, fire-control action, and...
ENSO controls interannual fire activity in southeast Australia
NASA Astrophysics Data System (ADS)
Mariani, M.; Fletcher, M.-S.; Holz, A.; Nyman, P.
2016-10-01
El Niño-Southern Oscillation (ENSO) is the main mode controlling the variability in the ocean-atmosphere system in the South Pacific. While the ENSO influence on rainfall regimes in the South Pacific is well documented, its role in driving spatiotemporal trends in fire activity in this region has not been rigorously investigated. This is particularly the case for the highly flammable and densely populated southeast Australian sector, where ENSO is a major control over climatic variability. Here we conduct the first region-wide analysis of how ENSO controls fire activity in southeast Australia. We identify a significant relationship between ENSO and both fire frequency and area burnt. Critically, wavelet analyses reveal that despite substantial temporal variability in the ENSO system, ENSO exerts a persistent and significant influence on southeast Australian fire activity. Our analysis has direct application for developing robust predictive capacity for the increasingly important efforts at fire management.
Bopp, L; Resplandy, L; Untersee, A; Le Mezo, P; Kageyama, M
2017-09-13
All Earth System models project a consistent decrease in the oxygen content of oceans for the coming decades because of ocean warming, reduced ventilation and increased stratification. But large uncertainties for these future projections of ocean deoxygenation remain for the subsurface tropical oceans where the major oxygen minimum zones are located. Here, we combine global warming projections, model-based estimates of natural short-term variability, as well as data and model estimates of the Last Glacial Maximum (LGM) ocean oxygenation to gain some insights into the major mechanisms of oxygenation changes across these different time scales. We show that the primary uncertainty on future ocean deoxygenation in the subsurface tropical oceans is in fact controlled by a robust compensation between decreasing oxygen saturation (O 2sat ) due to warming and decreasing apparent oxygen utilization (AOU) due to increased ventilation of the corresponding water masses. Modelled short-term natural variability in subsurface oxygen levels also reveals a compensation between O 2sat and AOU, controlled by the latter. Finally, using a model simulation of the LGM, reproducing data-based reconstructions of past ocean (de)oxygenation, we show that the deoxygenation trend of the subsurface ocean during deglaciation was controlled by a combination of warming-induced decreasing O 2sat and increasing AOU driven by a reduced ventilation of tropical subsurface waters.This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'. © 2017 The Author(s).
A sprinkling experiment to quantify celerity-velocity differences at the hillslope scale.
van Verseveld, Willem J; Barnard, Holly R; Graham, Chris B; McDonnell, Jeffrey J; Brooks, J Renée; Weiler, Markus
2017-01-01
Few studies have quantified the differences between celerity and velocity of hillslope water flow and explained the processes that control these differences. Here, we asses these differences by combining a 24-day hillslope sprinkling experiment with a spatially explicit hydrologic model analysis. We focused our work on Watershed 10 at the H. J. Andrews Experimental Forest in western Oregon. Celerities estimated from wetting front arrival times were generally much faster than average vertical velocities of δ 2 H. In the model analysis, this was consistent with an identifiable effective porosity (fraction of total porosity available for mass transfer) parameter, indicating that subsurface mixing was controlled by an immobile soil fraction, resulting in the attenuation of the δ 2 H input signal in lateral subsurface flow. In addition to the immobile soil fraction, exfiltrating deep groundwater that mixed with lateral subsurface flow captured at the experimental hillslope trench caused further reduction in the δ 2 H input signal. Finally, our results suggest that soil depth variability played a significant role in the celerity-velocity responses. Deeper upslope soils damped the δ 2 H input signal, while a shallow soil near the trench controlled the δ 2 H peak in lateral subsurface flow response. Simulated exit time and residence time distributions with our hillslope hydrologic model showed that water captured at the trench did not represent the entire modeled hillslope domain; the exit time distribution for lateral subsurface flow captured at the trench showed more early time weighting.
A sprinkling experiment to quantify celerity-velocity differences at the hillslope scale
NASA Astrophysics Data System (ADS)
van Verseveld, Willem J.; Barnard, Holly R.; Graham, Chris B.; McDonnell, Jeffrey J.; Renée Brooks, J.; Weiler, Markus
2017-11-01
Few studies have quantified the differences between celerity and velocity of hillslope water flow and explained the processes that control these differences. Here, we asses these differences by combining a 24-day hillslope sprinkling experiment with a spatially explicit hydrologic model analysis. We focused our work on Watershed 10 at the H. J. Andrews Experimental Forest in western Oregon. Celerities estimated from wetting front arrival times were generally much faster than average vertical velocities of δ2H. In the model analysis, this was consistent with an identifiable effective porosity (fraction of total porosity available for mass transfer) parameter, indicating that subsurface mixing was controlled by an immobile soil fraction, resulting in the attenuation of the δ2H input signal in lateral subsurface flow. In addition to the immobile soil fraction, exfiltrating deep groundwater that mixed with lateral subsurface flow captured at the experimental hillslope trench caused further reduction in the δ2H input signal. Finally, our results suggest that soil depth variability played a significant role in the celerity-velocity responses. Deeper upslope soils damped the δ2H input signal, while a shallow soil near the trench controlled the δ2H peak in lateral subsurface flow response. Simulated exit time and residence time distributions with our hillslope hydrologic model showed that water captured at the trench did not represent the entire modeled hillslope domain; the exit time distribution for lateral subsurface flow captured at the trench showed more early time weighting.
NASA Astrophysics Data System (ADS)
Bopp, L.; Resplandy, L.; Untersee, A.; Le Mezo, P.; Kageyama, M.
2017-08-01
All Earth System models project a consistent decrease in the oxygen content of oceans for the coming decades because of ocean warming, reduced ventilation and increased stratification. But large uncertainties for these future projections of ocean deoxygenation remain for the subsurface tropical oceans where the major oxygen minimum zones are located. Here, we combine global warming projections, model-based estimates of natural short-term variability, as well as data and model estimates of the Last Glacial Maximum (LGM) ocean oxygenation to gain some insights into the major mechanisms of oxygenation changes across these different time scales. We show that the primary uncertainty on future ocean deoxygenation in the subsurface tropical oceans is in fact controlled by a robust compensation between decreasing oxygen saturation (O2sat) due to warming and decreasing apparent oxygen utilization (AOU) due to increased ventilation of the corresponding water masses. Modelled short-term natural variability in subsurface oxygen levels also reveals a compensation between O2sat and AOU, controlled by the latter. Finally, using a model simulation of the LGM, reproducing data-based reconstructions of past ocean (de)oxygenation, we show that the deoxygenation trend of the subsurface ocean during deglaciation was controlled by a combination of warming-induced decreasing O2sat and increasing AOU driven by a reduced ventilation of tropical subsurface waters. This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'.
Using geophysical images of a watershed subsurface to predict soil textural properties
USDA-ARS?s Scientific Manuscript database
Subsurface architecture, in particular changes in soil type across the landscape, is an important control on the hydrological and ecological function of a watershed. Traditional methods of mapping soils involving subjective assignment of soil boundaries are inadequate for studies requiring a quantit...
KINETIC CONTROL OF OXIDATION STATE AT THERMODYNAMICALLY BUFFERED POTENTIALS IN SUBSURFACE WATERS
Dissolved oxygen (DO) and organic carbon (Corg) are among the highest- and lowest-potential reactants, respectively, of redox couples in natural waters. When DO and Corg are present in subsurface settings, other couples are drawn toward potentials imposed by them, generating a b...
A review of fire interactions and mass fires
Mark A. Finney; Sara S. McAllister
2011-01-01
The character of a wildland fire can change dramatically in the presence of another nearby fire. Understanding and predicting the changes in behavior due to fire-fire interactions cannot only be life-saving to those on the ground, but also be used to better control a prescribed fire to meet objectives. In discontinuous fuel types, such interactions may elicit fire...
Venn-Watson, Stephanie; Smith, Cynthia R; Jensen, Eric D; Rowles, Teri
2013-08-01
Firestorms negatively affected air quality throughout San Diego County during 2003 and 2007, including the San Diego Bay, which houses the Navy's bottlenose dolphins (Tursiops truncatus). To assess the potential impact of the 2003 and 2007 fires on dolphin health. Hematology and serum chemistry values were evaluated retrospectively among Navy dolphins the year and month before; during; and the month after the 2003 and 2007 fires. Both 2003 and 2007 fires were associated with lower calcium either during or the month post-fire compared to the control periods. During and the month following the 2003 fire, dolphins had higher serum carbon dioxide compared to the control periods. Dolphins during and the month following the 2007 fire had lower absolute or percent neutrophils and higher chloride. The 2007 fire was also associated with increased percent eosinophils during the fire and higher percent monocytes and bilirubin the month following the fire compared to the control periods. Consistent with what has been previously reported in humans and other animals, this study supports that fire smoke inhalation may have mild effects on dolphin physiology, including calcium homeostasis, lung function and immune response.
Combustion Processes in the Aerospace Environment
NASA Technical Reports Server (NTRS)
Huggett, Clayton
1969-01-01
The aerospace environment introduces new and enhanced fire hazards because the special atmosphere employed may increase the frequency and intensity of fires, because the confinement associated with aerospace systems adversely affects the dynamics of fire development and control, and because the hostile external environments limit fire control and rescue operations. Oxygen enriched atmospheres contribute to the fire hazard in aerospace systems by extending the list of combustible fuels, increasing the probability of ignition, and increasing the rates of fire spread and energy release. A system for classifying atmospheres according to the degree of fire hazard, based on the heat capacity of the atmosphere per mole of oxygen, is suggested. A brief exploration of the dynamics of chamber fires shows that such fires will exhibit an exponential growth rate and may grow to dangerous size in a very short time. Relatively small quantities of fuel and oxygen can produce a catastrophic fire in a closed chamber.
Spatio-temporal pattern of eco-environmental parameters in Jharia coalfield, India
NASA Astrophysics Data System (ADS)
Saini, V.; Gupta, R. P.; Arora, M. K.
2015-10-01
Jharia coal-field holds unequivocal importance in the Indian context as it is the only source of prime coking coal in the country. The coalfield is also known for its infamous coal mine fires which have been burning since last more than a century. Haphazard mining over a century has led to eco-environmental changes to a large extent such as changes in vegetation distribution and widespread development of surface and subsurface fires. This article includes the spatiotemporal study of remote sensing derived eco-environmental parameters like vegetation index (NDVI), tasseled cap transformation (TCT) and temperature distribution in fire areas. In order to have an estimate of the temporal variations of NDVI over the years, a study has been carried out on two subsets of the Jharia coalfield using Landsat images of 1972 (MSS), 1992 (TM), 1999 (ETM+) and 2013 (OLI). To assess the changes in brightness and greenness over the year s, difference images have been calculated using the 1992 (TM) and 2013 (OLI) images. Radiance images derived from thermal bands have been used to calculate at-sensor brightness temperature over a 23 year period from 1991 to 2013. It has been observed that during the years 1972 to 2013, moderate to dense vegetation has decreased drastically due to the intense mining going on in the area. TCT images show the areas that have undergone changes in both brightness and greenness from 1992 to 2013. Surface temperature data obtained shows a constant increase from 1991 to 2013 apparently due to coal fires. The utility of remote sensing data in such EIA studies has been emphasized.
8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), ...
8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), FROM ENTRYWAY, LOOKING NORTH, SHOWING ADDITIONAL 'GAMEWELL' FIRE ALARM SYSTEMS. - Oakland Naval Supply Center, Firehouse, East of Fourth Street, between A & B Streets, Oakland, Alameda County, CA
J. R. Miesel; R. E. J. Boerner; C. N. Skinner
2011-01-01
Forest thinning and prescribed fire are management strategies used to reduce hazardous fuel loads and catastrophic wildfires in western mixed-conifer forests. We evaluated effects of thinning (Thin) and prescribed fire (Burn), alone and in combination (Thin+Burn), on N transformations and microbial enzyme activities relative to an untreated control (Control) at 1 and 3...
NASA Astrophysics Data System (ADS)
Wuttke, M. W.; Kessels, W.; Wessling, S.; Han, J.
2007-05-01
Spontaneous combustion is a world wide problem for technical operations in mining, waste disposal and power plant facilities. The principle driving the combustion is every where the same independent of the different reactive materials: Fresh air with the common oxygen content is getting in contact with the reactive material by human operations. The following reaction process produces heat at a usually low but constant rate. The reactive material in operating or abandoned coal mines, heaps of coal, waste or reactive minerals is most times strongly broken or fractured, such that the atmospheric oxygen can deeply penetrate into the porous or fractured media. Because the strongly broken or fractured medium with air filled pores and fractures is often combined with a low thermal conductivity of the bulk material the produced heat accumulates and the temperature increases with time. If the reactivity strongly increases with temperature, the temperature rise accelerates up to the "combustion temperature". Once the temperature is high enough the combustion process is determined by the oxygen transport to the combustion center rather than the chemical reactivity. Spontaneous combustion is thus a self- amplifying process where an initial small variation in the parameters and the starting conditions can create exploding combustion hot spots in an apparently homogenous material. The phenomenon will be discussed by various examples in the context of the German - Sino coal fire project. A temperature monitoring in hot fracture systems documents the strong influence of the weather conditions on the combustion process. Numerical calculations show the sensitivity of the combustion to the model geometries, the boundary conditions and mainly the permeability. The most used fire fighting operations like covering and water injection are discussed. A new method of using saltwater for fire fighting is presented and discussed. References: Kessels, W., Wessling, S., Li, X., and Wuttke, M. W. Numerical element distinction for reactive transport modeling regarding reaction rate. In Proceedings of MODFLOW and MORE 2006: Managing Groundwater Systems, May 21 - 24, 2006, Golden, CO USA (2006). Kessels, W., Wuttke, M. W., Wessling, S., and Li, X. Coal fires between self ignition and fire fighting: Numerical modeling and basic geophysical measurements. In ERSEC Ecological Book Series - 4 on Coal Fire Research (2007). Wessling, S., Litschke, T., Wiegand, J., Schlömer, S., and Kessels, W. Simulating dynamic subsurface coal fires and its applications. In ERSEC Ecological Book Series - 4 on Coal Fire Reserach (2007). Wessling, S., Kessels, W., Schmidt, M., and Krause, U. Investigating dynamic underground coal fires by means of numerical simulation. Geophys. J. Int. (submitted).
Determinants of fire activity during the last 3500 yr at a wildland-urban interface, Alberta, Canada
NASA Astrophysics Data System (ADS)
Davis, Emma L.; Courtney Mustaphi, Colin J.; Gall, Amber; Pisaric, Michael F. J.; Vermaire, Jesse C.; Moser, Katrina A.
2016-11-01
Long-term records of wildfires and their controlling factors are important sources of information for informing land management practices. Here, dendrochronology and lake sediment analyses are used to develop a 3500-yr fire and vegetation history for a montane forest in Jasper National Park, Alberta, Canada. The tree-ring record (AD 1771-2012) indicates that this region historically experienced a mixed-severity fire regime, and that effective fire suppression excluded widespread fire events from the study area during the 20th century. A sediment core collected from Little Trefoil Lake, located near the Jasper townsite, is analyzed for subfossil pollen and macroscopic charcoal (>150 μm). When comparing the tree-ring record to the 3500-yr record of sediment-derived fire events, only high-severity fires are represented in the charcoal record. Comparisons between the charcoal record and historical climate and pollen data indicate that climate and vegetation composition have been important controls on the fire regime for most of the last 3500 yr. Although fire frequency is presently within the historical range of variability, the fire return interval of the last 150 yr is longer than expected given modern climate and vegetation conditions, indicating that humans have become the main control on fire activity around Little Trefoil Lake.
2006-08-01
SMP) 1 Trg Area 1330-1430 SMP 2 Trg Area 16 nov 0800-0900 SMP 3 Trg Area 0930-1200 Offensive Fire - LIVE FIRE Range 1 Range Complex 1300-1530 Command...Control Evaluation (C2) 1 Range Complex 1600-1700 SMP 4 Trg Area 17 nov 0930-1200 Defensive Fire - LIVE FIRE Range 2 Range Complex 1300-1530 Command...Control Evaluation (C2) 2 Range Complex 18 nov 0800-0900 SMP 5 Trg Area 0930-1200 Offensive Fire - LIVE FIRE Range 2 Range Complex 1300-1530
NASA Astrophysics Data System (ADS)
Oliver, G. C. M.; Cario, A.; Rogers, K. L.
2015-12-01
A majority of Earth's biosphere is hosted in subsurface environments where global-scale biogeochemical and energy cycles are driven by diverse microbial communities that operate on and are influenced by micro-scale environmental variables. While the subsurface hosts a variety of geochemical and geothermal conditions, elevated pressures are common to all subsurface ecosystems. Understanding how microbes adapt to and thrive in high-pressure environments is essential to linking microbial subsurface processes with global-scale cycles. Here we are using a model extremophile, Archaeoglobus fulgidus, to determine how elevated pressures affect the growth, metabolism, and physiology of subsurface microorganisms. A. fulgidus cycles carbon and sulfur via heterotrophic and autotrophic sulfate reduction in various high temperature and high-pressure niches including shallow marine vents, deep-sea hydrothermal vents, and deep oil reservoirs. Here we report the results of A. fulgidus growth experiments at optimum temperature, 83°C, and pressures up to 600 bars. Exponential growth was observed over the entire pressure range, though growth rates were diminished at 500 and 600 bars compared to ambient pressure experimental controls. At pressures up to 400 bars, cell density yields and growth rates were at least as high as ambient pressure controls. Elevated pressures and extended incubation times stimulated cell flocculation, a common stress response in this strain, and cellular morphology was affected at pressures exceeding 400 bars. These results suggest that A. fulgidus continues carbon, sulfur and energy cycling unaffected by elevated pressures up to 400 bars, representing a variety of subsurface environments. The ability of subsurface organisms to drive biogeochemical cycles at elevated pressures is a critical link between the surface and subsurface biospheres and understanding how species-scale processes operate under these conditions is a vital part of global-scale biogeochemical models.
Building systems and smoke control
NASA Astrophysics Data System (ADS)
Kawagoe, K.; Wakamatsu, T.; Morishita, Y.; Yamana, T.
The cost effectiveness of different approaches to fire prevention - sprinklers and detectors, increased use of smoke control devices, increased flammability standards, increased public education, increase fire prevention efforts, increased public fire services, etc. - need to be studied further as a guide to determining the emphasis appropriate for each. It is clear that detectors and sprinklers are making a difference in the fight to reduce fire losses. With continued effort the detectors' and sprinklers' full potential for saving lives and property from fire can be realized.
The purpose of the work was to determine the capability of various geophysical methods to detect PCE in the subsurface. Measurements were made with ten different geophysical techniques before, during, and after the PCE injection. This approach provided a clear identification of a...
Tetrachloroethylene (PCE), typically used as a dry cleaning solvent, is a predominant contaminant in the subsurface at Superfund Sites. PCE is a dense non-aqueous phase liquid (DNAPL) that migrates downward into the earth, leaving behind areas of residual saturation and free prod...
Fire safety concerns in space operations
NASA Technical Reports Server (NTRS)
Friedman, Robert
1987-01-01
This paper reviews the state-of-the-art in fire control techniques and identifies important issues for continuing research, technology, and standards. For the future permanent orbiting facility, the space station, fire prevention and control calls for not only more stringent fire safety due to the long-term and complex missions, but also for simplified and flexible safety rules to accommodate the variety of users. Future research must address a better understanding of the microgravity space environment as it influences fire propagation and extinction and the application of the technology of fire detection, extinguishment, and material assessment. Spacecraft fire safety should also consider the adaptation of methods and concepts derived from aircraft and undersea experience.
Fire management in central America
Andrea L. Koonce; Armando González-Cabán
1992-01-01
Information on fire management operations in Central America is scant. To evaluate the known level of fire occurrence in seven countries in that area, fire management officers were asked to provide information on their fire control organizations and on any available fire statistics. The seven countries surveyed were Guatemala, Belize, Honduras, El Salvador, Nicaragua,...
High virus-to-cell ratios indicate ongoing production of viruses in deep subsurface sediments.
Engelhardt, Tim; Kallmeyer, Jens; Cypionka, Heribert; Engelen, Bert
2014-07-01
Marine sediments cover two-thirds of our planet and harbor huge numbers of living prokaryotes. Long-term survival of indigenous microorganisms within the deep subsurface is still enigmatic, as sources of organic carbon are vanishingly small. To better understand controlling factors of microbial life, we have analyzed viral abundance within a comprehensive set of globally distributed subsurface sediments. Phages were detected by electron microscopy in deep (320 m below seafloor), ancient (∼14 Ma old) and the most oligotrophic subsurface sediments of the world's oceans (South Pacific Gyre (SPG)). The numbers of viruses (10(4)-10(9) cm(-3), counted by epifluorescence microscopy) generally decreased with sediment depth, but always exceeded the total cell counts. The enormous numbers of viruses indicate their impact as a controlling factor for prokaryotic mortality in the marine deep biosphere. The virus-to-cell ratios increased in deeper and more oligotrophic layers, exhibiting values of up to 225 in the deep subsurface of the SPG. High numbers of phages might be due to absorption onto the sediment matrix and a diminished degradation by exoenzymes. However, even in the oldest sediments, microbial communities are capable of maintaining viral populations, indicating an ongoing viral production and thus, viruses provide an independent indicator for microbial life in the marine deep biosphere.
Spatial controls of occurrence and spread of wildfires in the Missouri Ozark Highlands
Jian Yang; Hong S. He; Stephen R. Shifley
2008-01-01
Understanding spatial controls on wildfires is important when designing adaptive fire management plans and optimizing fuel treatment locations on a forest landscape. Previous research about this topic focused primarily on spatial controls for fire origin locations alone. Fire spread and behavior were largely overlooked. This paper contrasts the relative importance of...
New fire-fighting water bucket releases its water for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact- resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Comparing the role of fuel breaks across southern California national forests
Syphard, Alexandra D.; Keeley, Jon E.; Brennan, Teresa J.
2011-01-01
Fuel treatment of wildland vegetation is the primary approach advocated for mitigating fire risk at the wildland-urban interface (WUI), but little systematic research has been conducted to understand what role fuel treatments play in controlling large fires, which factors influence this role, or how the role of fuel treatments may vary over space and time. We assembled a spatial database of fuel breaks and fires from the last 30 years in four southern California national forests to better understand which factors are consistently important for fuel breaks in the control of large fires. We also explored which landscape features influence where fires and fuel breaks are most likely to intersect. The relative importance of significant factors explaining fuel break outcome and number of fire and fuel break intersections varied among the forests, which reflects high levels of regional landscape diversity. Nevertheless, several factors were consistently important across all the forests. In general, fuel breaks played an important role in controlling large fires only when they facilitated fire management, primarily by providing access for firefighting activities. Fire weather and fuel break maintenance were also consistently important. Models and maps predicting where fuel breaks and fires are most likely to intersect performed well in the regions where the models were developed, but these models did not extend well to other regions, reflecting how the environmental controls of fire regimes vary even within a single ecoregion. Nevertheless, similar mapping methods could be adopted in different landscapes to help with strategic location of fuel breaks. Strategic location of fuel breaks should also account for access points near communities, where fire protection is most important.
Techniques for Combined Arms for Air Defense
2016-07-29
loss remain in effect until communications are regained. Changes to ROE and supplemental fire control measures scheduled to go into effect after...communications are lost will be implemented as scheduled . Fire Control Orders Fire control orders are commands used to control engagements on a case...or a sleep matt over windshields (Figure 3-2). Camouflage is one of the basic weapons of war. The importance, the principles, and the techniques of
Impact of a low intensity controlled-fire in some chemical soil properties.
NASA Astrophysics Data System (ADS)
Martínez-Murillo, Juan F.; Hueso-González, Paloma; Aranda-Gómez, Francisco; Damián Ruiz-Sinoga, José
2014-05-01
Some changes in chemical soil properties can be observed after fires of low intensities. pH and electric conductivity tend to increase, while C/N ratio decrease. In the case of organic matter, the content can increase due to the massive incorporation of necromass including, especially, plants and roots. The aim of this study is to assess the impact of low intensity and controlled fire in some soil properties in field conditions. El Pinarillo experimental area is located in South of Spain. Two set of closed plots were installed (24 m2: 12 m length x 2 m width). One of them was remained as control with the original vegetation cover (Mediterranean matorral: Rosmarinus officinalis, Cistus clusii, Lavandula stoechas, Chamaeropos humilis, Thymus baetica), and the other one was burnt in a controlled-fire in 2011. Weather conditions and water content of vegetation influenced in the intensity of fire (low). After the controlled-fire, soil surface sample (0-5 cm) were taken in both set of plots (B, burnt soil samples; C, control soil samples). Some soil chemical properties were analysed: organic matter content (OM), C/N ratio, pH and electrical conductivity (EC). Some changes were observed in B corroborating a controlled-fire of low intensity. pH remained equal after fire (B: pH=7.7±0.11; C: pH=7.7±0.04). An increment was obtained in the case of EC (B: EC=0.45 mScm-1±0.08 mScm-1; C: EC=0.35 mScm-1±0.07 mScm-1) and OM (B: OM=8.7%±3.8%; C: pH=7.3%±1.5%). Finally, C/N ratio decreased after fire respect to the control and initial conditions (B: C/N=39.0±14.6; C: C/N =46.5±10.2).
[Research progress in post-fire debris flow].
Di, Xue-ying; Tao, Yu-zhu
2013-08-01
The occurrence of the secondary disasters of forest fire has significant impacts on the environment quality and human health and safety. Post-fire debris flow is one of the most hazardous secondary disasters of forest fire. To understand the occurrence conditions of post-fire debris flow and to master its occurrence situation are the critical elements in post-fire hazard assessment. From the viewpoints of vegetation, precipitation threshold and debris flow material sources, this paper elaborated the impacts of forest fire on the debris flow, analyzed the geologic and geomorphic conditions, precipitation and slope condition that caused the post-fire debris flow as well as the primary mechanisms of debris-flow initiation caused by shallow landslide or surface runoff, and reviewed the research progress in the prediction and forecast of post-fire debris flow and the related control measures. In the future research, four aspects to be focused on were proposed, i. e., the quantification of the relationships between the fire behaviors and environmental factors and the post-fire debris flow, the quantitative research on the post-fire debris flow initiation and movement processes, the mechanistic model of post-fire debris flow, and the rapid and efficient control countermeasures of post-fire debris flow.
Chapter 5. Borderlands fire regimes
Margot Wilkinson-Kaye; Thomas Swetnam; Christopher R. Baisan
2006-01-01
Fire is a keystone process in most natural, terrestrial ecosystems. The vital role that fire plays in controlling the structure of an ecosystem underscores the need for us to increase our knowledge of past and current fire regimes (Morgan and others 1994). Dendrochronological reconstructions of fire histories provide descriptions of past fire regimes across a range of...
NASA Astrophysics Data System (ADS)
Scaini, Anna; Hissler, Christophe; Fenicia, Fabrizio; Juilleret, Jérôme; Iffly, Jean François; Pfister, Laurent; Beven, Keith
2018-03-01
Subsurface flow is often recognized as a dominant runoff generation process. However, observing subsurface properties, and understanding how they control flow pathways, remains challenging. This paper investigates how surface slope and bedrock cleavage control subsurface flow pathways in a slate bedrock headwater catchment in Luxembourg, characterised by a double-peak streamflow response. We use a range of experimental techniques, including field observations of soil and bedrock characteristics, and a sprinkling experiment at a site located 40 m upslope from the stream channel. The sprinkling experiment uses Br- as a tracer, which is measured at a well downslope from the plot and at various locations along the stream, together with well and stream hydrometric responses. The sprinkling experiment is used to estimate velocities and celerities, which in turn are used to infer flow pathways. Our results indicate that the single or first peak of double-peak events is rainfall-driven (controlled by rainfall) while the second peak is storage-driven (controlled by storage). The comparison between velocity and celerity estimates suggests a fast flowpath component connecting the hillslope to the stream, but velocity information was too scarce to fully support such a hypothesis. In addition, different estimates of celerities suggest a seasonal influence of both rainfall intensity rate and residual water storage on the celerity responses at the hillslope scale. At the catchment outlet, the estimated of the total mass of Br- recovered in the stream was about 2.5% of the application. Further downstream, the estimate mass of Br- was about 4.0% of the application. This demonstrates that flowpaths do not appear to align with the slope gradient. In contrast, they appear to follow the strike of the bedrock cleavage. Our results have expanded our understanding of the importance of the subsurface, in particular the underlying bedrock systems, and the importance of cleavage orientation, as well as topography, in controlling subsurface flow direction in this catchment.
Induction of antimicrobial 3-deoxyflavonoids in pome fruit trees controls fire blight.
Halbwirth, Heidrun; Fischer, Thilo C; Roemmelt, Susanne; Spinelli, Francesco; Schlangen, Karin; Peterek, Silke; Sabatini, Emidio; Messina, Christian; Speakman, John-Bryan; Andreotti, Carlo; Rademacher, Wilhelm; Bazzi, Carlo; Costa, Guglielmo; Treutter, Dieter; Forkmann, Gert; Stich, Karl
2003-01-01
Fire blight, a devastating bacterial disease in pome fruits, causes severe economic losses worldwide. Hitherto, an effective control could only be achieved by using antibiotics, but this implies potential risks for human health, livestock and environment. A new approach allows transient inhibition of a step in the flavonoid pathway, thereby inducing the formation of a novel antimicrobial 3-deoxyflavonoid controlling fire blight in apple and pear leaves. This compound is closely related to natural phytoalexins in sorghum. The approach does not only provide a safe method to control fire blight: Resistance against different pathogens is also induced in other crop plants.
NASA Technical Reports Server (NTRS)
Coulbert, C. D.
1978-01-01
A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.
Does prescribed fire benefit wetland vegetation?
Flores, C.; Bounds, D.L.; Ruby, D.E.
2011-01-01
The effects of fire on wetland vegetation in the mid-Atlantic region of the United States are poorly known, despite the historical use of fire by federal, state, and private landowners in the Chesapeake Bay Region. Prescribed fire is widely used by land managers to promote vegetation that is beneficial to migratory waterfowl, muskrats, and other native wildlife and to reduce competition from less desirable plant species. We compared vegetative response to two fire rotations, annual burns and 3-year burns, and two control sites, Control 1 and Control 2. We tested the effects of fire within six tidal marsh wetlands at Blackwater National Wildlife Refuge and Fishing Bay Wildlife Management Area in Maryland. We examined changes in total live biomass (all species), total stem density, litter, and changes in live biomass and stem density of four dominant wetland plant species (11 variables). Our results suggest that annual prescribed fires will decrease the accumulation of litter, increase the biomass and stem densities of some wetland plants generally considered less desirable for wildlife, and have little or no effect on other wetland plants previously thought to benefit from fire. ?? 2011 US Government.
Fire and climate variation in western North America from fire-scar and tree-ring networks
Donald A. Falk; E. K. Heyerdahl; P. M. Brown; T. W. Swetnam; E. K. Sutherland; Z. Gedalof; L. Yocom; T. J. Brown
2010-01-01
Fire regimes (i.e., the pattern, frequency and intensity of fire in a region) reflect a complex interplay of bottom-up and top-down controls (Lertzman et al., 1998; Mc Kenzie et al., in press). Bottom-up controls include local variations in topographic, fuel and weather factors at the time of a burn (e.g., fuel moisture and continuity, ignition density and local wind...
77. Deputy commander's launch control console, fire control panel missing ...
77. Deputy commander's launch control console, fire control panel missing at right, south side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
Flammability Configuration Analysis for Spacecraft Applications
NASA Technical Reports Server (NTRS)
Pedley, Michael D.
2014-01-01
Fire is one of the many potentially catastrophic hazards associated with the operation of crewed spacecraft. A major lesson learned by NASA from the Apollo 204 fire in 1966 was that ignition sources in an electrically powered vehicle should and can be minimized, but can never be eliminated completely. For this reason, spacecraft fire control is based on minimizing potential ignition sources and eliminating materials that can propagate fire. Fire extinguishers are always provided on crewed spacecraft, but are not considered as part of the fire control process. "Eliminating materials that can propagate fire" does not mean eliminating all flammable materials - the cost of designing and building spacecraft using only nonflammable materials is extraordinary and unnecessary. It means controlling the quantity and configuration of such materials to eliminate potential fire propagation paths and thus ensure that any fire would be small, localized, and isolated, and would self-extinguish without harm to the crew. Over the years, NASA has developed many solutions for controlling the configuration of flammable materials (and potentially flammable materials in commercial "off-the-shelf" hardware) so that they can be used safely in air and oxygen-enriched environments in crewed spacecraft. This document describes and explains these design solutions so payload customers and other organizations can use them in designing safe and cost-effective flight hardware. Proper application of these guidelines will produce acceptable flammability configurations for hardware located in any compartment of the International Space Station or other program crewed vehicles and habitats. However, use of these guidelines does not exempt hardware organizations of the responsibility for safety of the hardware under their control.
Riparian corridors in upland watersheds in the Great Basin of central Nevada contain the majority of the region's biodiversity. Water, in both surface and subsurface flow regimes, is an important resource sustaining these sensitive ecosystems and other similar riparian ecosystem...
Drilling Automation Demonstrations in Subsurface Exploration for Astrobiology
NASA Technical Reports Server (NTRS)
Glass, Brian; Cannon, H.; Lee, P.; Hanagud, S.; Davis, K.
2006-01-01
This project proposes to study subsurface permafrost microbial habitats at a relevant Arctic Mars-analog site (Haughton Crater, Devon Island, Canada) while developing and maturing the subsurface drilling and drilling automation technologies that will be required by post-2010 missions. It builds on earlier drilling technology projects to add permafrost and ice-drilling capabilities to 5m with a lightweight drill that will be automatically monitored and controlled in-situ. Frozen cores obtained with this drill under sterilized protocols will be used in testing three hypotheses pertaining to near-surface physical geology and ground H2O ice distribution, viewed as a habitat for microbial life in subsurface ice and ice-consolidated sediments. Automation technologies employed will demonstrate hands-off diagnostics and drill control, using novel vibrational dynamical analysis methods and model-based reasoning to monitor and identify drilling fault states before and during faults. Three field deployments, to a Mars-analog site with frozen impact crater fallback breccia, will support science goals, provide a rigorous test of drilling automation and lightweight permafrost drilling, and leverage past experience with the field site s particular logistics.
Hwang, V; Duchossois, G P; Garcia‐Espana, J F; Durbin, D R
2006-01-01
The objective of this study was to determine the impact of a community based fire prevention intervention directed only to parents on the fire safety knowledge and behavior in elementary school children. This was a prospective, quasi‐randomized controlled study in which third and fourth grade students from two elementary schools in an urban, poor, minority community completed knowledge/behavior surveys at baseline and following completion of the intervention. The intervention group received an in‐home visit from fire department personnel who installed free lithium smoke detectors and provided a fire escape plan. After accounting for a small difference in baseline summary scores of knowledge and behavior between the control and intervention groups, this study found a modest improvement in fire safety behavior among children whose families received a fire prevention intervention reflecting a change in household fire safety practices. However, there was no significant change in fire safety knowledge. PMID:17018679
Subsurface thermal coagulation of tissues using near infrared lasers
NASA Astrophysics Data System (ADS)
Chang, Chun-Hung Jack
Noninvasive laser therapy is currently limited primarily to cosmetic dermatological applications such as skin resurfacing, hair removal, tattoo removal and treatment of vascular birthmarks. In order to expand applications of noninvasive laser therapy, deeper optical penetration of laser radiation in tissue as well as more aggressive cooling of the tissue surface is necessary. The near-infrared laser wavelength of 1075 nm was found to be the optimal laser wavelength for creation of deep subsurface thermal lesions in liver tissue, ex vivo, with contact cooling, preserving a surface tissue layer of 2 mm. Monte Carlo light transport, heat transfer, and Arrhenius integral thermal damage simulations were conducted at this wavelength, showing good agreement between experiment and simulations. Building on the initial results, our goal is to develop new noninvasive laser therapies for application in urology, specifically for treatment of female stress urinary incontinence (SUI). Various laser balloon probes including side-firing and diffusing fibers were designed and tested for both transvaginal and transurethral approaches to treatment. The transvaginal approach showed the highest feasibility. To further increase optical penetration depth, various types and concentrations of optical clearing agents were also explored. Three cadavers studies were performed to investigate and demonstrate the feasibility of laser treatment for SUI.
Aircraft Engine Sump Fire Mitigation
NASA Technical Reports Server (NTRS)
Rosenlieb, J. W.
1973-01-01
An investigation was performed of the conditions in which fires can result and be controlled within the bearing sump simulating that of a gas turbine engine; Esso 4040 Turbo Oil, Mobil Jet 2, and Monsanto MCS-2931 lubricants were used. Control variables include the oil inlet temperature, bearing temperature, oil inlet and scavenge rates, hot air inlet temperature and flow rate, and internal sump baffling. In addition to attempting spontaneous combustion, an electric spark and a rub (friction) mechanism were employed to ignite fires. Spontaneous combustion was not obtained; however, fires were readily ignited with the electric spark while using each of the three test lubricants. Fires were also ignited using the rub mechanism with the only test lubricant evaluated, Esso 4040. Major parameters controlling ignitions were: Sump configuration; Bearing and oil temperatures, hot air temperature and flow and bearing speed. Rubbing between stationary parts and rotating parts (eg. labyrinth seal and mating rub strip) is a very potent fire source suggesting that observed accidental fires in gas turbine sumps may well arise from this cause.
A Cloud Based Framework For Monitoring And Predicting Subsurface System Behaviour
NASA Astrophysics Data System (ADS)
Versteeg, R. J.; Rodzianko, A.; Johnson, D. V.; Soltanian, M. R.; Dwivedi, D.; Dafflon, B.; Tran, A. P.; Versteeg, O. J.
2015-12-01
Subsurface system behavior is driven and controlled by the interplay of physical, chemical, and biological processes which occur at multiple temporal and spatial scales. Capabilities to monitor, understand and predict this behavior in an effective and timely manner are needed for both scientific purposes and for effective subsurface system management. Such capabilities require three elements: Models, Data and an enabling cyberinfrastructure, which allow users to use these models and data in an effective manner. Under a DOE Office of Science funded STTR award Subsurface Insights and LBNL have designed and implemented a cloud based predictive assimilation framework (PAF) which automatically ingests, controls quality and stores heterogeneous physical and chemical subsurface data and processes these data using different inversion and modeling codes to provide information on the current state and evolution of subsurface systems. PAF is implemented as a modular cloud based software application with five components: (1) data acquisition, (2) data management, (3) data assimilation and processing, (4) visualization and result delivery and (5) orchestration. Serverside PAF uses ZF2 (a PHP web application framework) and Python and both open source (ODM2) and in house developed data models. Clientside PAF uses CSS and JS to allow for interactive data visualization and analysis. Client side modularity (which allows for a responsive interface) of the system is achieved by implementing each core capability of PAF (such as data visualization, user configuration and control, electrical geophysical monitoring and email/SMS alerts on data streams) as a SPA (Single Page Application). One of the recent enhancements is the full integration of a number of flow and mass transport and parameter estimation codes (e.g., MODFLOW, MT3DMS, PHT3D, TOUGH, PFLOTRAN) in this framework. This integration allows for autonomous and user controlled modeling of hydrological and geochemical processes. In our presentation we will discuss our software architecture and present the results of using these codes and the overall developed performance of our framework using hydrological, geochemical and geophysical data from the LBNL SFA2 Rifle field site.
Extinguishing Agent for Magnesium Fire: Phases 5 and 6.
1987-07-01
This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases I-IV. The results of this...system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires . The specifications developed for...the agent and for the delivery system are discussed in detail. Keywords: Fire suppression, Metal fires , Fire extinguishers.
Sean A. Parks; Lisa M. Holsinger; Carol Miller; Cara R. Nelson
2015-01-01
Theory suggests that natural fire regimes can result in landscapes that are both self-regulating and resilient to fire. For example, because fires consume fuel, they may create barriers to the spread of future fires, thereby regulating fire size. Top-down controls such as weather, however, can weaken this effect. While empirical examples demonstrating this pattern-...
Dale G. Brockway; Kenneth W Outcalt
2005-01-01
The principal objective is to quantify the responses of the understory plant community to fire and fire surrogate treatments, specifically plant species composition, foliar cover, species richness, diversity, and evenness changes resulting from (1) fire exclusion in the untreated control, (2) prescribed fire, (3) thinning, (4) thinning plus prescribed fire, and (5)...
Helen H. Mohr; Thomas A. Waldrop; Sandra Rideout; Ross J. Phillips; Charles T. Flint
2004-01-01
The need for fuel reduction has increased in United States forests due to decades of fire exclusion. Excessive fuel buildup has led to uncharacteristically severe fires in areas with historically short-interval, low-to-moderate-intensity fire regimes. The National Fire and Fire Surrogate (NFFS) Study compared the impacts of three fuel-reduction treatments on numerous...
Controls on carbon consumption during Alaskan wildland fires
Eric S. Kasischke; Elizabeth E. Hoy
2012-01-01
A method was developed to estimate carbon consumed during wildland fires in interior Alaska based on medium-spatial scale data (60 m cell size) generated on a daily basis. Carbon consumption estimates were developed for 41 fire events in the large fire year of 2004 and 34 fire events from the small fire years of 2006-2008. Total carbon consumed during the large fire...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., but without an insulation core, are acceptable if an automatic sprinkler or deluge system is installed... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... following means to control the spread of fire, smoke, and toxic gases underground in the event of a fire...
Impacts of prescribed fire on Pinus rigida Mill. in upland forests of the Atlantic Coastal Plain.
Carlo, Nicholas J; Renninger, Heidi J; Clark, Kenneth L; Schäfer, Karina V R
2016-08-01
A comparative analysis of the impacts of prescribed fire on three upland forest stands in the Northeastern Atlantic Plain, NJ, USA, was conducted. Effects of prescribed fire on water use and gas exchange of overstory pines were estimated via sap-flux rates and photosynthetic measurements on Pinus rigida Mill. Each study site had two sap-flux plots, one experiencing prescribed fire and one control (unburned) plot for comparison before and after the fire. We found that photosynthetic capacity in terms of Rubisco-limited carboxylation rate and intrinsic water-use efficiency was unaffected, while light compensation point and dark respiration rate were significantly lower in the burned vs control plots post-fire. Furthermore, quantum yield in pines in the pine-dominated stands was less affected than pines in the mixed oak/pine stand, as there was an increase in quantum yield in the oak/pine stand post-fire compared with the control (unburned) plot. We attribute this to an effect of forest type but not fire per se. Average daily sap-flux rates of the pine trees increased compared with control (unburned) plots in pine-dominated stands and decreased in the oak/pine stand compared with control (unburned) plots, potentially due to differences in fuel consumption and pre-fire sap-flux rates. Finally, when reference canopy stomatal conductance was analyzed, pines in the pine-dominated stands were more sensitive to changes in vapor pressure deficit (VPD), while stomatal responses of pines in the oak/pine stand were less affected by VPD. Therefore, prescribed fire affects physiological functioning and water use of pines, but the effects may be modulated by forest stand type and fuel consumption pattern, which suggests that these factors may need to be taken into account for forest management in fire-dominated systems. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Geomorphic factors related to the persistence of subsurface oil from the Exxon Valdez oil spill
Nixon, Zachary; Michel, Jacqueline; Hayes, Miles O.; Irvine, Gail V.; Short, Jeffrey
2013-01-01
Oil from the 1989 Exxon Valdez oil spill has persisted along shorelines of Prince William Sound, Alaska, for more than two decades as both surface and subsurface oil residues. To better understand the distribution of persistent subsurface oil and assess the potential need for further restoration, a thorough and quantitative understanding of the geomorphic factors controlling the presence or absence of subsurface oil is required. Data on oiling and geomorphic features were collected at 198 sites in Prince William Sound to identify and quantify the relationships among these geomorphic factors and the presence and absence of persistent subsurface oil. Geomorphic factors associated with the presence of subsurface oil were initial oil exposure, substrate permeability, topographic slope, low exposure to waves, armoring on gravel beaches, tombolos, natural breakwaters, and rubble accumulations. Geomorphic factors associated with the absence of subsurface oil were impermeable bedrock; platforms with thin sediment veneer; fine-grained, well-sorted gravel beaches with no armor; and low-permeability, raised bay-bottom beaches. Relationships were found between the geomorphic and physical site characteristics and the likelihood of encountering persistent subsurface oiling at those sites. There is quantitative evidence of more complex interactions between the overall wave energy incident at a site and the presence of fine-scale geomorphic features that may have provided smaller, local wave energy sheltering of oil. Similarly, these data provide evidence for interactions between the shoreline slope and the presence of angular rubble, with decreased likelihood for encountering subsurface oil at steeply sloped sites except at high-angle sheltered rubble shoreline locations. These results reinforce the idea that the interactions of beach permeability, stability, and site-specific wave exposure are key drivers for subsurface oil persistence in exposed and intermittently exposed mixed gravel beach and rocky shoreline environments.
Fire-management policies and programs
S.J. Husari; K.S. McKelvey
1996-01-01
For most of this century the goal of fire management in the Sierra was to control fire. The policy was aggressively and successfully ap-plied, substantially reducing annual acres burned. This goal was based on a fire policy that emphasized keeping wildland fires as small and inexpensive as possible. As the role of fire in maintaining Sierran ecosystems has been...
Jeremy S. Littell; David L. Peterson; Karin L. Riley; Yongqiang Liu; Charles H. Luce
2016-01-01
Historical and presettlement relationships between drought and wildfire have been well documented in much of North America, with forest fire occurrence and area burned clearly increasing in response to drought. Drought interacts with other controls (forest productivity, topography, and fire weather) to affect fire intensity and severity. Fire regime characteristics (...
1. Photographic copy of fire alarm plan for Control and ...
1. Photographic copy of fire alarm plan for Control and Recording Center Building 4221/E-22, showing layout of rooms. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Edwards Test Station, Fire Alarm Plan, Bldg. E-22,' drawing no. EFA/11-1, December 15, 1961. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Näthe, Kerstin; Michalzik, Beate; Levia, Delphis; Steffens, Markus
2016-04-01
Fires represent an ecosystem disturbance and are recognized to seriously pertubate the nutrient budgets of forested ecosystems. While the effects of fires on chemical, biological, and physical soil properties have been intensively studied, especially in Mediterranean areas and North America, few investigations examined the effects of fire-induced alterations in the water-bound fluxes and the chemical composition of dissolved and particulate organic carbon and nitrogen (DOC, POC, DN, PN). The exclusion of the particulate organic matter fraction (0.45 μm < POM < 500 μm) potentially results in misleading inferences and budgeting gaps when studying the effects of fires on nutrient and energy fluxes. To our best knowledge, this is the first known study to present fire-induced changes on the composition of dissolved and total organic matter (DOM, TOM) in forest floor (FF) and soil solutions (A, B horizon) from Scots pine forests in Germany. In relation to control sites, we test the effects of low-severity fires on: (1) the composition of DOM and TOM in forest floor and soil solutions; and (2) the translocated amount of particulate in relation to DOC and DN into the subsoil. The project aims to uncover the mechanisms of water-bound organic matter transport along an ecosystem profile and its compositional changes following a fire disturbance. Forest floor and soil solutions were fortnightly sampled from March to December 2014 on fire-manipulated and control plots in a Scots pine forest in Central Germany. Shortly after the experimental duff fire in April 2014 pooled solutions samples were taken for solid-state 13C NMR spectroscopy to characterize DOM (filtered solution < 0.8μm pore size) and TOM in unfiltered solutions. Independent from fire manipulation, the composition of TOM was generally less aromatic (aromaticity index [%] according to Hatcher et al., 1981) with values between 18 (FF) - 25% (B horizon) than the DOM fraction with 23 (FF) - 27% (B horizon). For DOM in FF solution, fire manipulation caused an increase in aromaticity from 23 to 27% compared to the control, due to an increase of the aryl-C and a decrease of the O-alkyl-C and alkyl-C signal. Fire effects were leveled out in the mineral soil. For TOM, fire effects became notable only in the A horizon, exhibiting a decrease in aromaticity from 22 to 18% compared to the control, due to increased O-alkyl-C and diminished aryl-C proportions. Compared to the control, fire only caused minor DOC release rates (< 10%) in the FF and mineral soil, while DN in the FF was significantly mobilized (+ 40%) by fire exhibiting annual values of 33 at the control sites compared to 46 kg DN ha-1 at the fire treated sites. Compared to the control, fire events did not significantly enhance the proportion of POC and PN in the total C and N amounts exhibiting values between 10 and 20%. To fully understand the quality and amount of translocated organic C and N compounds within soils under both ambient as well as fire environments, dissolved and particulate size fractions need to be considered.
Active fungi amidst a marine subsurface RNA paleome
NASA Astrophysics Data System (ADS)
Orsi, W.; Biddle, J.; Edgcomb, V.
2012-12-01
The deep marine subsurface is a vast habitat for microbial life where cells may live on geologic timescales. Since extracellular DNA in sediments may be preserved on long timescales, ribosomal RNA (rRNA) is suggested to be a proxy for the active fraction of a microbial community in the subsurface. During an investigation of eukaryotic 18S rRNA signatures by amplicon pyrosequencing, metazoan, plant, and diatom rRNA signatures were recovered from marine sediments up to 2.7 million years old, suggesting that rRNA may be much more stable than previously considered in the marine subsurface. This finding confirms the concept of a paleome, extending it to include rRNA. Within the same dataset, unique profiles of fungi were found across a range of marine subsurface provinces exhibiting statistically significant correlations with total organic carbon (TOC), sulfide, and dissolved inorganic carbon (DIC). Sequences from metazoans, plants and diatoms showed different correlation patterns, consistent with a depth-controlled paleome. The fungal correlations with geochemistry allow the inference that some fungi are active and adapted for survival in the marine subsurface. A metatranscriptomic analysis of fungal derived mRNA confirms that fungi are metabolically active and utilize a range of organic and inorganic substrates in the marine subsurface.
Holocene evolution of the North Atlantic subsurface transport
NASA Astrophysics Data System (ADS)
Repschläger, Janne; Garbe-Schönberg, Dieter; Weinelt, Mara; Schneider, Ralph
2017-04-01
Previous studies suggested that short-term freshening events in the subpolar gyre can be counterbalanced by advection of saline waters from the subtropical gyre and thus stabilize the Atlantic Meridional Overturning Circulation (AMOC). However, little is known about the inter-gyre transport pathways. Here, we infer changes in surface and subsurface transport between the subtropical and polar North Atlantic during the last 11 000 years, by combining new temperature and salinity reconstructions obtained from combined δ18O and Mg / Ca measurements on surface and subsurface dwelling foraminifera with published foraminiferal abundance data from the subtropical North Atlantic, and with salinity and temperature data from the tropical and subpolar North Atlantic. This compilation implies an overall stable subtropical warm surface water transport since 10 ka BP. In contrast, subsurface warm water transport started at about 8 ka but still with subsurface heat storage in the subtropical gyre. The full strength of intergyre exchange was probably reached only after the onset of northward transport of warm saline subsurface waters at about 7 ka BP, associated with the onset of the modern AMOC mode. A critical evaluation of different potential forcing mechanisms leads to the assumption that freshwater supply from the Laurentide Ice Sheet was the main control on subtropical to subpolar ocean transport at surface and subsurface levels.
... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...
Sletto, Bjørn; Rodriguez, Iokiñe
2013-01-30
Wildland fire management in savanna landscapes increasingly incorporates indigenous knowledge to pursue strategies of controlled, prescriptive burning to control fuel loads. However, such participatory approaches are fraught with challenges because of contrasting views on the role of fire and the practices of prescribed burning between indigenous and state fire managers. Also, indigenous and state systems of knowledge and meanings associated with fire are not monolithic but instead characterized by conflicts and inconsistencies, which require new, communicative strategies in order to develop successful, intercultural approaches to fire management. This paper is based on long-term research on indigenous Pemon social constructs, rules and regulations regarding fire use, and traditional system of prescribed burning in the Gran Sabana, Venezuela. The authors review factors that act as constraints against successful intercultural fire management in the Gran Sabana, including conflicting perspectives on fire use within state agencies and in indigenous communities, and propose strategies for research and communicative planning to guide future efforts for more participatory and effective fire management. Copyright © 2012 Elsevier Ltd. All rights reserved.
Utilization of remote sensing in Alaska permafrost studies
NASA Technical Reports Server (NTRS)
Hall, D. K.
1981-01-01
Permafrost related features such as: aufeis, tundra, thaw lakes and subsurface ice features were studied. LANDSAT imagery was used to measure the extent and distribution of aufeis in Arctic Slope rivers over a period of 7 years. Interannual extent of large aufeis fields was found to vary significantly. Digital LANDSAT data were used to study the short term effects of a tundra fire which burned a 48 sq km area in northwestern Alaska. Vegetation regrowth was inferred from Landsat spectral reflectance increases and compared to in-situ measurements. Aircraft SAR (Synethic Aperture Radar) imagery was used in conjunction with LANDSAT imagery used in conjunction with LANDSAT imagery to qualitatively determine depth categories for thaw lakes in northern Alaska.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L.
Compositional feed limits have been established to ensure that a nuclear criticality event for the 2H and 3H Evaporators is not possible. The Enrichment Control Program (ECP) requires feed sampling to determine the equivalent enriched uranium content prior to transfer of waste other than recycle transfers (requires sampling to determine the equivalent enriched uranium at two locations in Tanks 38H and 43H every 26 weeks) The Corrosion Control Program (CCP) establishes concentration and temperature limits for key constituents and periodic sampling and analysis to confirm that waste supernate is within these limits. This report provides the results of analyses onmore » Tanks 38H and 43H surface and subsurface supernatant liquid samples in support of the ECP, the CCP, and the Salt Batch 10 Planning Program.« less
42 CFR 403.744 - Condition of participation: Life safety from fire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... written fire control plans that contain provisions for prompt reporting of fires; extinguishing fires...) The RNHCI must maintain written evidence of regular inspection and approval by State or local fire... contrary, the RNHCI may place alcohol-based hand rub dispensers in its facility if— (i) Use of alcohol...
Cross-scale analysis of fire regimes
Donald A. Falk; Carol Miller; Donald McKenzie; Anne E. Black
2007-01-01
Cross-scale spatial and temporal perspectives are important for studying contagious landscape disturbances such as fire, which are controlled by myriad processes operating at different scales. We examine fire regimes in forests of western North America, focusing on how observed patterns of fire frequency change across spatial scales. To quantify changes in fire...
14 CFR 23.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... protective devices. (4) Means available for controlling or extinguishing a fire, such as stopping flow of...
Prediction errors in wildland fire situation analyses.
Geoffrey H. Donovan; Peter Noordijk
2005-01-01
Wildfires consume budgets and put the heat on fire managers to justify and control suppression costs. To determine the appropriate suppression strategy, land managers must conduct a wildland fire situation analysis (WFSA) when:A wildland fire is expected to or does escape initial attack,A wildland fire managed for resource benefits...
Krawchuk, Meg A.; Haire, Sandra L.; Coop, Jonathan D.; Parisien, Marc-Andre; Whitman, Ellen; Chong, Geneva W.; Miller, Carol
2016-01-01
for seven study fires that burned in conifer-dominated forested landscapes of the Western Cordillera of Canada between 2001 and 2014. We fit nine models, each for distinct levels of fire weather and terrain ruggedness. Our framework revealed that the predictability and abundance of fire refugia varied among these environmental settings. We observed highest predictability under moderate fire weather conditions and moderate terrain ruggedness (ROC-AUC = 0.77), and lowest predictability in flatter landscapes and under high fire weather conditions (ROC-AUC = 0.63–0.68). Catchment slope, local aspect, relative position, topographic wetness, topographic convergence, and local slope all contributed to discriminating where refugia occur but the relative importance of these topographic controls differed among environments. Our framework allows us to characterize the predictability of contemporary fire refugia across multiple environmental settings and provides important insights for ecosystem resilience, wildfire management, conservation planning, and climate change adaptation.
Distribution of black carbon in Ponderosa pine litter and soils following the High Park wildfire
NASA Astrophysics Data System (ADS)
Boot, C. M.; Haddix, M.; Paustian, K.; Cotrufo, M. F.
2014-12-01
Black carbon (BC), the heterogeneous product of burned biomass, is a critical component in the global carbon cycle, yet timescales and mechanisms for incorporation into the soil profile are not well understood. The High Park Fire, which took place in northwestern Colorado in the summer of 2012, provided an opportunity to study the effects of both fire intenstiy and geomorphology on properties of carbon (C), nitrogen (N), and BC in the Cache La Poudre River drainage. We sampled montane Ponderosa pine litter, 0-5 cm soils, and 5-15 cm soils four months post-fire in order to examine the effects of slope and burn intensity on %C, C stocks, %N and black carbon (g kg-1 C, and g m-2). We developed and implemented the benzene polycarboxylic acid (BPCA) method for quantifying BC. With regard to slope, we found that steeper slopes had higher C : N than shallow slopes, but that there was no difference in black carbon content or stocks. BC content was greatest in the litter in burned sites (19 g kg-1 C), while BC stocks were greatest in the 5-15 cm subsurface soils (23 g m-2). At the time of sampling, none of the BC deposited on the land surface post-fire had been incorporated into to either the 0-5 cm or 5-15 cm soil layers. The ratio of B5CA : B6CA (less condensed to more condensed BC) indicated there was significantly more older, more processed BC at depth. Total BC soil stocks were relatively low compared to other fire-prone grassland and boreal forest systems, indicating most of the BC produced in this system is likely transported off the surface through erosion events. Future work examining mechanisms for BC transport will be required for understanding the role BC plays in the global carbon cycle.
James D. McIver; Scott L. Stephens; James K. Agee; Jamie Barbour; Ralph E. J. Boerner; Carl B. Edminster; Karen L. Erickson; Kerry L. Farris; Christopher J. Fettig; Carl E. Fiedler; Sally Haase; Stephen C. Hart; Jon E. Keeley; Eric E. Knapp; John F. Lehmkuhl; Jason J. Moghaddas; William Otrosina; Kenneth W. Outcalt; Dylan W. Schwilk; Carl N. Skinner; Thomas A. Waldrop; C. Phillip Weatherspoon; Daniel A. Yaussy; Andrew Youngblood; Steve Zack
2012-01-01
The 12-site National Fire and Fire Surrogate study (FFS) was a multivariate experiment that evaluated ecological consequences of alternative fuel-reduction treatments in seasonally dry forests of the US. Each site was a replicated experiment with a common design that compared an un-manipulated control, prescribed fire, mechanical and mechanical + fire treatments....
Optogenetic feedback control of neural activity
Newman, Jonathan P; Fong, Ming-fai; Millard, Daniel C; Whitmire, Clarissa J; Stanley, Garrett B; Potter, Steve M
2015-01-01
Optogenetic techniques enable precise excitation and inhibition of firing in specified neuronal populations and artifact-free recording of firing activity. Several studies have suggested that optical stimulation provides the precision and dynamic range requisite for closed-loop neuronal control, but no approach yet permits feedback control of neuronal firing. Here we present the ‘optoclamp’, a feedback control technology that provides continuous, real-time adjustments of bidirectional optical stimulation in order to lock spiking activity at specified targets over timescales ranging from seconds to days. We demonstrate how this system can be used to decouple neuronal firing levels from ongoing changes in network excitability due to multi-hour periods of glutamatergic or GABAergic neurotransmission blockade in vitro as well as impinging vibrissal sensory drive in vivo. This technology enables continuous, precise optical control of firing in neuronal populations in order to disentangle causally related variables of circuit activation in a physiologically and ethologically relevant manner. DOI: http://dx.doi.org/10.7554/eLife.07192.001 PMID:26140329
Combinational logic for generating gate drive signals for phase control rectifiers
NASA Technical Reports Server (NTRS)
Dolland, C. R.; Trimble, D. W. (Inventor)
1982-01-01
Control signals for phase-delay rectifiers, which require a variable firing angle that ranges from 0 deg to 180 deg, are derived from line-to-line 3-phase signals and both positive and negative firing angle control signals which are generated by comparing current command and actual current. Line-to-line phases are transformed into line-to-neutral phases and integrated to produce 90 deg phase delayed signals that are inverted to produce three cosine signals, such that for each its maximum occurs at the intersection of positive half cycles of the other two phases which are inputs to other inverters. At the same time, both positive and negative (inverted) phase sync signals are generated for each phase by comparing each with the next and producing a square wave when it is greater. Ramp, sync and firing angle controls signals are than used in combinational logic to generate the gate firing control signals SCR gate drives which fire SCR devices in a bridge circuit.
Interpretation of Ground Temperature Anomalies in Hydrothermal Discharge Areas
NASA Astrophysics Data System (ADS)
Price, A. N.; Lindsey, C.; Fairley, J. P., Jr.
2017-12-01
Researchers have long noted the potential for shallow hydrothermal fluids to perturb near-surface temperatures. Several investigators have made qualitative or semi-quantitative use of elevated surface temperatures; for example, in snowfall calorimetry, or for tracing subsurface flow paths. However, little effort has been expended to develop a quantitative framework connecting surface temperature observations with conditions in the subsurface. Here, we examine an area of shallow subsurface flow at Burgdorf Hot Springs, in the Payette National Forest, north of McCall, Idaho USA. We present a simple analytical model that uses easily-measured surface data to infer the temperatures of laterally-migrating shallow hydrothermal fluids. The model is calibrated using shallow ground temperature measurements and overburden thickness estimates from seismic refraction studies. The model predicts conditions in the shallow subsurface, and suggests that the Biot number may place a more important control on the expression of near-surface thermal perturbations than previously thought. In addition, our model may have application in inferring difficult-to-measure parameters, such as shallow subsurface discharge from hydrothermal springs.
Method for determining depth and shape of a sub-surface conductive object
NASA Astrophysics Data System (ADS)
Lee, D. O.; Montoya, P. C.; Wayland, J. R., Jr.
1984-06-01
The depth to and size of an underground object may be determined by sweeping a controlled source audio magnetotelluric (CSAMT) signal and locating a peak response when the receiver spans the edge of the object. The depth of the object is one quarter wavelength in the subsurface media of the frequency of the peak.
Fire Extinguisher Robot Using Ultrasonic Camera and Wi-Fi Network Controlled with Android Smartphone
NASA Astrophysics Data System (ADS)
Siregar, B.; Purba, H. A.; Efendi, S.; Fahmi, F.
2017-03-01
Fire disasters can occur anytime and result in high losses. It is often that fire fighters cannot access the source of fire due to the damage of building and very high temperature, or even due to the presence of explosive materials. With such constraints and high risk in the handling of the fire, a technological breakthrough that can help fighting the fire is necessary. Our paper proposed the use of robots to extinguish the fire that can be controlled from a specified distance in order to reduce the risk. A fire extinguisher robot was assembled with the intention to extinguish the fire by using a water pump as actuators. The robot movement was controlled using Android smartphones via Wi-fi networks utilizing Wi-fi module contained in the robot. User commands were sent to the microcontroller on the robot and then translated into robotic movement. We used ATMega8 as main microcontroller in the robot. The robot was equipped with cameras and ultrasonic sensors. The camera played role in giving feedback to user and in finding the source of fire. Ultrasonic sensors were used to avoid collisions during movement. Feedback provided by camera on the robot displayed on a screen of smartphone. In lab, testing environment the robot can move following the user command such as turn right, turn left, forward and backward. The ultrasonic sensors worked well that the robot can be stopped at a distance of less than 15 cm. In the fire test, the robot can perform the task properly to extinguish the fire.
Adaptive reference voltage generator for firing angle control of line-commutated inverters
NASA Technical Reports Server (NTRS)
Dolland, C. R. (Inventor)
1983-01-01
A control system for a permanent-magnet motor driven by a multiphase line-commulated inverter is described. It is provided with integrators for integrating the back EMF of each phase of the motor for use in generating system control signals for an inverter gate logic using a sync and firing angle control generator connected to the outputs of the integrators. The firing angle control signals are produced by the control generator by means for combining 120 deg segments of the integrated back EMF signals symmetrical about their maxima into composite positive and negative waveforms, and means for sampling the maxima of each waveform every 120 deg. These samples are then used as positive and negative firing angle control signals. Whereby any change in amplitude of the integrated back EMF signals will not affect a change in the operating power factor of the motor and inverter.
Anderson, R Hunter; Long, G Cornell; Porter, Ronald C; Anderson, Janet K
2016-05-01
The use of aqueous film-forming foam (AFFF) to extinguish hydrocarbon-based fires is recognized as a significant source of environmental poly- and perfluoroalkyl substances (PFASs). Although the occurrence of select PFASs in soil and groundwater at former fire-training areas (FTAs) at military installations operable since 1970 has been consistently confirmed, studies reporting the occurrence of PFASs at other AFFF-impacted sites (e.g. emergency response locations, AFFF lagoons, hangar-related AFFF storage tanks and pipelines, and fire station testing and maintenance areas) are largely missing from the literature. Further, studies have mostly focused on a single site (i.e., FTAs at military installations) and, thus, lack a comparison of sites with diverse AFFF release history. Therefore, the purpose of this investigation was to evaluate select PFAS occurrence at non-FTA sites on active U.S. Air Force installations with historic AFFF use of varying magnitude. Concentrations of fifteen perfluoroalkyl acids (PFAAs) and perfluorooctane sulfonamide (PFOSA), an important PFOS precursor, were measured from several hundred samples among multiple media (i.e., surface soil, subsurface soil, sediment, surface water, and groundwater) collected from forty AFFF-impacted sites across ten installations between March and September 2014, representing one of the most comprehensive datasets on environmental PFAS occurrence to date. Differences in detection frequencies and observed concentrations due to AFFF release volume are presented along with rigorous data analyses that quantitatively demonstrate phase-dependent (i.e., solid-phase vs aqueous-phase) differences in the chemical signature as a function of carbon chain-length and in situ PFOS (and to a slightly lesser extent PFHxS) formation, presumably due to precursor biotransformation. Published by Elsevier Ltd.
Analysis of toxic effluents released from PVC carpet under different fire conditions.
Stec, A A; Readman, J; Blomqvist, P; Gylestam, D; Karlsson, D; Wojtalewicz, D; Dlugogorski, B Z
2013-01-01
A large number of investigations have been reported on minimising the PAH and PCDD/F yields during controlled combustion, such as incineration. This study is an attempt to quantify acute and chronic toxicants including PAH and PCDD/F in conditions relating to unwanted fires. This paper investigates distribution patterns of fire effluents between gas and aerosol phase, and the different particle size-ranges produced under different fire conditions. PVC carpet was selected as the fuel as a precursor for both PAH and PCDD/F. In order to generate fire effluents under controlled fire conditions, the steady-state tube furnace, was chosen as the physical fire model. Fire scenarios included oxidative pyrolysis, well-ventilated and under-ventilated fires. Fire effluent measurements included: carbon monoxide, carbon dioxide, hydrogen chloride, polycyclic aromatic hydrocarbons, chlorinated dibenzo-dioxins and furans and soot. The distribution patterns between gas and particle phase, and the size-ranges of the particles produced in these fires together with their chemical composition is also reported. Significant quantities of respirable submicron particles were detected, together with a range of PAHs. Lower levels of halogenated dioxins were detected in the fire residue compared with those found in other studies. Nevertheless, the findings do have implications for the health and safety of fire and rescue personnel, fire investigators, and other individuals exposed to the residue from unwanted fires. Copyright © 2012 Elsevier Ltd. All rights reserved.
Fire characteristics associated with firefighter injury on large federal wildland fires.
Britton, Carla; Lynch, Charles F; Torner, James; Peek-Asa, Corinne
2013-02-01
Wildland fires present many injury hazards to firefighters. We estimate injury rates and identify fire-related factors associated with injury. Data from the National Interagency Fire Center from 2003 to 2007 provided the number of injuries in which the firefighter could not return to his or her job assignment, person-days worked, and fire characteristics (year, region, season, cause, fuel type, resistance to control, and structures destroyed). We assessed fire-level risk factors of having at least one reported injury using logistic regression. Negative binomial regression was used to examine incidence rate ratios associated with fire-level risk factors. Of 867 fires, 9.5% required the most complex management and 24.7% required the next-highest level of management. Fires most often occurred in the western United States (82.8%), during the summer (69.6%), caused by lightening (54.9%). Timber was the most frequent fuel source (40.2%). Peak incident management level, person-days of exposure, and the fire's resistance to control were significantly related to the odds of a fire having at least one reported injury. However, the most complex fires had a lower injury incidence rate than less complex fires. Although fire complexity and the number of firefighters were associated with the risk for at least one reported injury, the more experienced and specialized firefighting teams had lower injury incidence. Copyright © 2013 Elsevier Inc. All rights reserved.
Control effects of stimulus paradigms on characteristic firings of parkinsonism
NASA Astrophysics Data System (ADS)
Zhang, Honghui; Wang, Qingyun; Chen, Guanrong
2014-09-01
Experimental studies have shown that neuron population located in the basal ganglia of parkinsonian primates can exhibit characteristic firings with certain firing rates differing from normal brain activities. Motivated by recent experimental findings, we investigate the effects of various stimulation paradigms on the firing rates of parkinsonism based on the proposed dynamical models. Our results show that the closed-loop deep brain stimulation is superior in ameliorating the firing behaviors of the parkinsonism, and other control strategies have similar effects according to the observation of electrophysiological experiments. In addition, in conformity to physiological experiments, we found that there exists optimal delay of input in the closed-loop GPtrain|M1 paradigm, where more normal behaviors can be obtained. More interestingly, we observed that W-shaped curves of the firing rates always appear as stimulus delay varies. We furthermore verify the robustness of the obtained results by studying three pallidal discharge rates of the parkinsonism based on the conductance-based model, as well as the integrate-and-fire-or-burst model. Finally, we show that short-term plasticity can improve the firing rates and optimize the control effects on parkinsonism. Our conclusions may give more theoretical insight into Parkinson's disease studies.
Talking Fire Alarms Calm Kids.
ERIC Educational Resources Information Center
Executive Educator, 1984
1984-01-01
The new microprocessor-based fire alarm systems can help to control smoke movement throughout school buildings by opening vents and doors, identify the burning section, activate voice alarms, provide firefighters with telephone systems during the fire, and release fire-preventing gas. (KS)
Integrating Geohydrological Models In ATES-Systems Control
NASA Astrophysics Data System (ADS)
Bloemendal, Martin
2015-04-01
1) Purpose. Accomplish optimal and sustainable use of subsurface for Aquifer Thermal Energy Storage (ATES). 2) Scope. A heat pump in combination with an ATES system can efficiently and sustainably provide heating and cooling for user comfort within buildings. ATES systems are popular in moderate climate in which ATES systems are exploited as they are able to save primary energy. While storing warm and cold groundwater, ATES systems occupy a significant amount of the subsurface space, making that the space in the aquifers below cities is becoming scarce [1]. With the rapid growth of the number of ATES systems, the use of the subsurface intensifies, which raises additional questions regarding its sustainability and the long term profitability of the individual systems. In practice considerable difficulties regarding A) the performance of these installations and B) optimal and sustainable use of the subsurface are met. 3) Approach. Recently it was confirmed [2] that ATES systems can be placed closer to each other with limited effect on their energy efficiency. By placing them closer together we introduce the risk of a tragedy of the commons [3]. Therefore it is of importance to know where the warm and cold zones are over time and enable ATES-controllers to use the subsurface optimal and sustainably. From the field of multi agent systems and complex adaptive systems we use approaches and techniques to make an operation and control system that enables to adapt their control not only based on current demand, but also on current aquifer status and expected future demand. We are developing a numerical groundwater model structure which is fed with operational data of different ATES-systems. While doing this we run into challenges and opportunities like; spatial and temporal scale issues, sustaining the storage with balancing thermal storage and extraction at area level, dynamics and relation between hydrological and thermal influence and consequences for spreading of contaminants, using thermal energy storage for "peak-shaving" of wind/solar power production etc.. I will address the following two topics; - Balancing of stored heating and cooling capacity. To sustain an ATES-system heating and cooling capacity storage must more or less balance. Buildings often do not have a similar heating and cooling demand. Placing ATES-well closer to each other offers the opportunity to exchange energy between different buildings in the subsurface to balance heating and cooling capacity. To be able to do so, thorough understanding of the interaction between thermal influence area resulting from highly dynamic and uncertain energy demand from buildings is required. - The hydrological influence area of ATES wells is much bigger than the thermal influence area. Placing wells closer to each other therefor has a significant effect on the mixing of water and spreading of contaminants (which are often present in shallow aquifers under (old) city centers). We use both analytical and numerical approaches to gain insight in patterns of thermal and contaminant spreading and to find solutions in managing these effects. 4) Results and conclusions The subsurface is of crucial importance for intended energy savings. A control system working towards a global optimum for both the subsurface and buildings, instead of a local optimum for an individual building and local ATES will increase the overall efficiency. What is needed for that is insight in the spatial temperature distribution in the subsurface, in combination with adaptive and robust operational rules. We want to prove that a groundwater model simulating active ATES-systems can provide insight in the subsurface temperature distribution to adjust their control strategy in accordance with up-to-date information. Step by step we are solving the problems on this path, I would like to share and discuss my results, solutions and challenges. References [1] Bloemendal, M., Olsthoorn, T., Boons, F., How to achieve optimal and sustainable use of the subsurface for Aquifer Thermal Energy Storage, Energy Policy 66(2014) 104-114 [2] Sommer, W., Valstar, J., Leusbrock, I., Grotenhuis, T., Rijnaarts, H., Optimization and spatial pattern of large-scale aquifer thermal energy storage, Applied Energy 137 (2015) 322-337 [3] Hardin, G., The tragedy of the commons, Science162 (168) 12-13.
Operating room fire prevention: creating an electrosurgical unit fire safety device.
Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J
2014-08-01
To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P < 0.0001). The exact 95% confidence interval for absolute risk reduction of fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.
76 FR 1192 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-07
..., the Commonwealth will control particulate matter emissions at the facilities by either shutting down coal-fired boilers, installing air emission controls, or converting the coal-fired boilers to natural gas-fired boilers. The Commonwealth will pay a civil penalty of $300,000 for past violations. The...
Fire in longleaf pine stand management: an economic analysis
Rodney L. Busby; Donald G. Hodges
1999-01-01
A simulation analysis of the economics of using prescribed fire as a forest management tool in the management of longleaf pine (Pinus palustris Mill.) plantations was conducted. A management regime using frequent prescribed fire was compared to management regimes involving fertilization and chemical release, chemical control, and mechanical control. Determining the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... treatment methods would include manual, mechanical, and biological control treatments, prescribed fire or wildland fire for resource benefit, and other management actions. In order to implement the proposed 3 Bars... enhancement, fire and fuels management, control of weeds, woodland and rangeland values, wetland and riparian...
Code of Federal Regulations, 2014 CFR
2014-10-01
... fire detector and control unit must be of a type specifically approved by the Commandant (CG-ENG). (b) No fire-alarm circuit for the engine room may contain a fire detector for any other space. (c) The number and placement of fire detectors must be approved by the cognizant OCMI. [CGD 82-004 and CGD 86-074...
Code of Federal Regulations, 2011 CFR
2011-10-01
... fire detector and control unit must be of a type specifically approved by the Commandant (CG-521). (b) No fire-alarm circuit for the engine room may contain a fire detector for any other space. (c) The number and placement of fire detectors must be approved by the cognizant OCMI. [CGD 82-004 and CGD 86-074...
Code of Federal Regulations, 2010 CFR
2010-10-01
... fire detector and control unit must be of a type specifically approved by the Commandant (CG-521). (b) No fire-alarm circuit for the engine room may contain a fire detector for any other space. (c) The number and placement of fire detectors must be approved by the cognizant OCMI. [CGD 82-004 and CGD 86-074...
Code of Federal Regulations, 2013 CFR
2013-10-01
... fire detector and control unit must be of a type specifically approved by the Commandant (CG-ENG). (b) No fire-alarm circuit for the engine room may contain a fire detector for any other space. (c) The number and placement of fire detectors must be approved by the cognizant OCMI. [CGD 82-004 and CGD 86-074...
Code of Federal Regulations, 2012 CFR
2012-10-01
... fire detector and control unit must be of a type specifically approved by the Commandant (CG-ENG). (b) No fire-alarm circuit for the engine room may contain a fire detector for any other space. (c) The number and placement of fire detectors must be approved by the cognizant OCMI. [CGD 82-004 and CGD 86-074...
Alan H. Taylor; Carl N. Skinner
2003-01-01
Fire exclusion in mixed conifer forests has increased the risk of fire due to decades of fuel accumulation. Restoration of fire into altered forests is a challenge because of a poor understanding of the spatial and temporal dynamics of fire regimes. In this study the spatial and temporal characteristics of fire regimes and forest age structure are reconstructed in a...
Strategies for preventing invasive plant outbreaks after prescribed fire in ponderosa pine forest
Symstad, Amy J.; Newton, Wesley E.; Swanson, Daniel J.
2014-01-01
Land managers use prescribed fire to return a vital process to fire-adapted ecosystems, restore forest structure from a state altered by long-term fire suppression, and reduce wildfire intensity. However, fire often produces favorable conditions for invasive plant species, particularly if it is intense enough to reveal bare mineral soil and open previously closed canopies. Understanding the environmental or fire characteristics that explain post-fire invasive plant abundance would aid managers in efficiently finding and quickly responding to fire-caused infestations. To that end, we used an information-theoretic model-selection approach to assess the relative importance of abiotic environmental characteristics (topoedaphic position, distance from roads), pre-and post-fire biotic environmental characteristics (forest structure, understory vegetation, fuel load), and prescribed fire severity (measured in four different ways) in explaining invasive plant cover in ponderosa pine forest in South Dakota’s Black Hills. Environmental characteristics (distance from roads and post-fire forest structure) alone provided the most explanation of variation (26%) in post-fire cover of Verbascum thapsus (common mullein), but a combination of surface fire severity and environmental characteristics (pre-fire forest structure and distance from roads) explained 36–39% of the variation in post-fire cover of Cirsium arvense (Canada thistle) and all invasives together. For four species and all invasives together, their pre-fire cover explained more variation (26–82%) in post-fire cover than environmental and fire characteristics did, suggesting one strategy for reducing post-fire invasive outbreaks may be to find and control invasives before the fire. Finding them may be difficult, however, since pre-fire environmental characteristics explained only 20% of variation in pre-fire total invasive cover, and less for individual species. Thus, moderating fire intensity or targeting areas of high severity for post-fire invasive control may be the most efficient means for reducing the chances of post-fire invasive plant outbreaks when conducting prescribed fires in this region.
The State of Stress Beyond the Borehole
NASA Astrophysics Data System (ADS)
Johnson, P. A.; Coblentz, D. D.; Maceira, M.; Delorey, A. A.; Guyer, R. A.
2015-12-01
The state of stress controls all in-situ reservoir activities and yet we lack the quantitative means to measure it. This problem is important in light of the fact that the subsurface provides more than 80 percent of the energy used in the United States and serves as a reservoir for geological carbon sequestration, used fuel disposition, and nuclear waste storage. Adaptive control of subsurface fractures and fluid flow is a crosscutting challenge being addressed by the new Department of Energy SubTER Initiative that has the potential to transform subsurface energy production and waste storage strategies. Our methodology to address the above mentioned matter is based on a novel Advance Multi-Physics Tomographic (AMT) approach for determining the state of stress, thereby facilitating our ability to monitor and control subsurface geomechanical processes. We developed the AMT algorithm for deriving state-of-stress from integrated density and seismic velocity models and demonstrate the feasibility by applying the AMT approach to synthetic data sets to assess accuracy and resolution of the method as a function of the quality and type of geophysical data. With this method we can produce regional- to basin-scale maps of the background state of stress and identify regions where stresses are changing. Our approach is based on our major advances in the joint inversion of gravity and seismic data to obtain the elastic properties for the subsurface; and coupling afterwards the output from this joint-inversion with theoretical model such that strain (and subsequently) stress can be computed. Ultimately we will obtain the differential state of stress over time to identify and monitor critically stressed faults and evolving regions within the reservoir, and relate them to anthropogenic activities such as fluid/gas injection.
Retrofitted coal-fired firetube boiler and method employed therewith
Wagoner, Charles L.; Foote, John P.
1995-01-01
A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler, the converted boiler including a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones.
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
Bird, Douglas W.; Codding, Brian F.
2016-01-01
While evidence mounts that indigenous burning has a significant role in shaping pyrodiversity, the processes explaining its variation across local and external biophysical systems remain limited. This is especially the case with studies of climate–fire interactions, which only recognize an effect of humans on the fire regime when they act independently of climate. In this paper, we test the hypothesis that an anthropogenic fire regime (fire incidence, size and extent) does not covary with climate. In the lightning regime, positive El Niño southern oscillation (ENSO) values increase lightning fire incidence, whereas La Niña (and associated increases in prior rainfall) increase fire size. ENSO has the opposite effect in the Martu regime, decreasing ignitions in El Niño conditions without affecting fire size. Anthropogenic ignition rates covary positively with high antecedent rainfall, whereas fire size varies only with high temperatures and unpredictable winds, which may reduce control over fire spread. However, total area burned is similarly predicted by antecedent rainfall in both regimes, but is driven by increases in fire size in the lightning regime, and fire number in the anthropogenic regime. We conclude that anthropogenic regimes covary with climatic variation, but detecting the human–climate–fire interaction requires multiple measures of both fire regime and climate. This article is part of the themed issue ‘The interaction of fire and mankind’. PMID:27216513
Climatic and Landscape Influences on Fire Regimes from 1984 to 2010 in the Western United States
Liu, Zhihua; Wimberly, Michael C.
2015-01-01
An improved understanding of the relative influences of climatic and landscape controls on multiple fire regime components is needed to enhance our understanding of modern fire regimes and how they will respond to future environmental change. To address this need, we analyzed the spatio-temporal patterns of fire occurrence, size, and severity of large fires (> 405 ha) in the western United States from 1984–2010. We assessed the associations of these fire regime components with environmental variables, including short-term climate anomalies, vegetation type, topography, and human influences, using boosted regression tree analysis. Results showed that large fire occurrence, size, and severity each exhibited distinctive spatial and spatio-temporal patterns, which were controlled by different sets of climate and landscape factors. Antecedent climate anomalies had the strongest influences on fire occurrence, resulting in the highest spatial synchrony. In contrast, climatic variability had weaker influences on fire size and severity and vegetation types were the most important environmental determinants of these fire regime components. Topography had moderately strong effects on both fire occurrence and severity, and human influence variables were most strongly associated with fire size. These results suggest a potential for the emergence of novel fire regimes due to the responses of fire regime components to multiple drivers at different spatial and temporal scales. Next-generation approaches for projecting future fire regimes should incorporate indirect climate effects on vegetation type changes as well as other landscape effects on multiple components of fire regimes. PMID:26465959
NASA Astrophysics Data System (ADS)
Rush, M.; Rajaram, H.; Anderson, R. S.; Anderson, S. P.
2017-12-01
The Intergovernmental Panel on Climate Change (2013) warns that high-elevation ecosystems are extremely vulnerable to climate change due to short growing seasons, thin soils, sparse vegetation, melting glaciers, and thawing permafrost. Many permafrost-free regions experience seasonally frozen ground. The spatial distribution of frozen soil exerts a strong control on subsurface flow and transport processes by reducing soil permeability and impeding infiltration. Accordingly, evolution of the extent and duration of frozen ground may alter streamflow seasonality, groundwater flow paths, and subsurface storage, presenting a need for coupled thermal-hydrologic models to project hydrologic responses to climate warming in high-elevation regions. To be useful as predictive tools, such models should incorporate the heterogeneity of solar insolation, vegetation, and snowpack dynamics. We present a coupled thermal-hydrologic modeling study against the backdrop of field observations from Gordon Gulch, a seasonally snow-covered montane catchment in the Colorado Front Range in the Boulder Creek Critical Zone Observatory. The field site features two instrumented hillslopes with opposing aspects: the snowpack on the north-facing slope persists throughout much of the winter season, while the snowpack on the south-facing slope is highly ephemeral. We implemented a surface energy balance and snowpack accumulation and ablation model that is coupled to the subsurface flow and transport code PFLOTRAN-ICE to predict the hydrologic consequences of aspect-controlled frozen soil formation during water years 2013-2016. Preliminary model results demonstrate the occurrence of seasonally-frozen ground on the north-facing slope that directs snowmelt to the stream by way of shallow subsurface flow paths. The absence of persistently frozen ground on the south-facing slope allows deeper infiltration of snowmelt recharge. The differences in subsurface flow paths also suggest strong aspect-controlled heterogeneities in nitrate export and differences in geomorphic processes such as frost creep.
Characterization of potential fire regimes: applying landscape ecology to fire management in Mexico
NASA Astrophysics Data System (ADS)
Jardel, E.; Alvarado, E.; Perez-Salicrup, D.; Morfín-Rios, J.
2013-05-01
Knowledge and understanding of fire regimes is fundamental to design sound fire management practices. The high ecosystem diversity of Mexico offers a great challenge to characterize the fire regime variation at the landscape level. A conceptual model was developed considering the main factors controlling fire regimes: climate and vegetation cover. We classified landscape units combining bioclimatic zones from the Holdridge life-zone system and actual vegetation cover. Since bioclimatic conditions control primary productivity and biomass accumulation (potential fuel), each landscape unit was considered as a fuel bed with a particular fire intensity and behavior potential. Climate is also a determinant factor of post-fire recovery rates of fuel beds, and climate seasonality (length of the dry and wet seasons) influences fire probability (available fuel and ignition efficiency). These two factors influence potential fire frequency. Potential fire severity can be inferred from fire frequency, fire intensity and behavior, and vegetation composition and structure. Based in the conceptual model, an exhaustive literature review and expert opinion, we developed rules to assign a potential fire regime (PFR) defined by frequency, intensity and severity (i.e. fire regime) to each bioclimatic-vegetation landscape unit. Three groups and eight types of potential fire regimes were identified. In Group A are fire-prone ecosystems with frequent low severity surface fires in grasslands (PFR type I) or forests with long dry season (II) and infrequent high-severity fires in chaparral (III), wet temperate forests (IV, fire restricted by humidity), and dry temperate forests (V, fire restricted by fuel recovery rate). Group B includes fire-reluctant ecosystems with very infrequent or occasional mixed severity surface fires limited by moisture in tropical rain forests (VI) or fuel availability in seasonally dry tropical forests (VII). Group C and PFR VIII include fire-free environments that correspond to deserts. Application of PFR model to fire management is discussed.
viral abundance distribution in deep waters of the Northern of South China Sea
NASA Astrophysics Data System (ADS)
He, Lei; Yin, Kedong
2017-04-01
Little is known about the vertical distribution and interaction of viruses and bacteria in the deep ocean water column. The vertical distribution of viral-like particles and bacterial abundance was investigated in the deep water column in the South China Sea during September 2005 along with salinity, temperature and dissolved oxygen. There were double maxima in the ratio of viral to bacterial abundance (VBR) in the water column: the subsurface maximum located at 50-100 m near the pycnocline layer, and the deep maximum at 800-1000 m. At the subsurface maximum of VBR, both viral and bacterial abundance were maximal in the water column, and at the deep maximum of VBR, both viral and bacterial abundance were low, but bacterial abundance was relatively lower than viral abundance. The subsurface VBR maximum coincided with the subsurface chlorophyll maximum while the deep VBR maximum coincided with the minimum in dissolved oxygen (2.91mg L-1). Therefore, we hypothesize that the two maxima were formed by different mechanisms. The subsurface VBR maximum was formed due to an increase in bacterial abundance resulting from the stimulation of abundant organic supply at the subsurface chlorophyll maximum, whereas the deep VBR maximum was formed due to a decrease in bacterial abundance caused by more limitation of organic matter at the oxygen minimum. The evidence suggests that viruses play an important role in controlling bacterial abundance in the deep water column due to the limitation of organic matter supply. In turn, this slows down the formation of the oxygen minimum in which oxygen may be otherwise lower. The mechanism has a great implication that viruses could control bacterial decomposition of organic matter, oxygen consumption and nutrient remineralization in the deep oceans.
Watts, D B; Way, T R; Torbert, H A
2011-01-01
Environmental pressure to reduce nutrient losses from agricultural fields has increased in recent years. To abate this nutrient loss to the environment, better management practices and new technologies need to be developed. Thus, research was conducted to evaluate if subsurface banding poultry litter (PL) would reduce nitrogen (N) and phosphorus (P) loss in surface water runoff using a four-row prototype implement. Rainfall simulations were conducted to create a 40-min runoff event in an established bermudagrass (Cynodon dactylon L.) pasture on soil types common to the Coastal Plain and Piedmont regions. The Coastal Plain soil type was a Marvyn loamy sand (fine-loamy, kaolinitic, thermic Typic Kanhapludults) and the Piedmont soil type was a Hard Labor loamy sand (fine, kaolinitic, thermic Oxyaquic Kanhapludults). Treatments consisted of surface- and subsurface-applied PL at a rate of 9 Mg ha(-1), surface broadcast-applied commercial fertilizer (CF; urea and triple superphosphate blend) at the equivalent N (330 kg N ha(-1)) and P (315 kg N ha(-1)) content of PL, and a nonfertilized control. The greatest loss for inorganic N, total N, dissolved reactive P (DRP), and total P occurred with the surface broadcast treatments, with CF contributing to the greatest loss. Nutrient losses from the subsurface banded treatment reduced N and P in surface water runoff to levels of the control. Subsurface banding of PL reduced concentrations of inorganic N 91%, total N 90%, DRP 86%, and total P 86% in runoff water compared with surface broadcasted PL. These results show that subsurface band-applied PL can greatly reduce the impact of N and P loss to the environment compared with conventional surface-applied PL and CF practices.
46 CFR 63.20-1 - Specific control system requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... interlock must ensure low fire start when variable firing rates are used. (c) Water level controls and low water cutoff controls. Water level controls must be constructed and located to minimize the effects of vessel roll and pitch. Float chamber low water cutoff controls using stuffing boxes to transmit the...
46 CFR 63.20-1 - Specific control system requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... interlock must ensure low fire start when variable firing rates are used. (c) Water level controls and low water cutoff controls. Water level controls must be constructed and located to minimize the effects of vessel roll and pitch. Float chamber low water cutoff controls using stuffing boxes to transmit the...
46 CFR 63.20-1 - Specific control system requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... interlock must ensure low fire start when variable firing rates are used. (c) Water level controls and low water cutoff controls. Water level controls must be constructed and located to minimize the effects of vessel roll and pitch. Float chamber low water cutoff controls using stuffing boxes to transmit the...
Singh, Rajveer; Sivaguru, Mayandi; Fried, Glenn A; Fouke, Bruce W; Sanford, Robert A; Carrera, Martin; Werth, Charles J
2017-09-01
Physical, chemical, and biological interactions between groundwater and sedimentary rock directly control the fundamental subsurface properties such as porosity, permeability, and flow. This is true for a variety of subsurface scenarios, ranging from shallow groundwater aquifers to deeply buried hydrocarbon reservoirs. Microfluidic flow cells are now commonly being used to study these processes at the pore scale in simplified pore structures meant to mimic subsurface reservoirs. However, these micromodels are typically fabricated from glass, silicon, or polydimethylsiloxane (PDMS), and are therefore incapable of replicating the geochemical reactivity and complex three-dimensional pore networks present in subsurface lithologies. To address these limitations, we developed a new microfluidic experimental test bed, herein called the Real Rock-Microfluidic Flow Cell (RR-MFC). A porous 500μm-thick real rock sample of the Clair Group sandstone from a subsurface hydrocarbon reservoir of the North Sea was prepared and mounted inside a PDMS microfluidic channel, creating a dynamic flow-through experimental platform for real-time tracking of subsurface reactive transport. Transmitted and reflected microscopy, cathodoluminescence microscopy, Raman spectroscopy, and confocal laser microscopy techniques were used to (1) determine the mineralogy, geochemistry, and pore networks within the sandstone inserted in the RR-MFC, (2) analyze non-reactive tracer breakthrough in two- and (depth-limited) three-dimensions, and (3) characterize multiphase flow. The RR-MFC is the first microfluidic experimental platform that allows direct visualization of flow and transport in the pore space of a real subsurface reservoir rock sample, and holds potential to advance our understandings of reactive transport and other subsurface processes relevant to pollutant transport and cleanup in groundwater, as well as energy recovery. Copyright © 2017 Elsevier B.V. All rights reserved.
Deep subsurface microbial processes
Lovley, D.R.; Chapelle, F.H.
1995-01-01
Information on the microbiology of the deep subsurface is necessary in order to understand the factors controlling the rate and extent of the microbially catalyzed redox reactions that influence the geophysical properties of these environments. Furthermore, there is an increasing threat that deep aquifers, an important drinking water resource, may be contaminated by man's activities, and there is a need to predict the extent to which microbial activity may remediate such contamination. Metabolically active microorganisms can be recovered from a diversity of deep subsurface environments. The available evidence suggests that these microorganisms are responsible for catalyzing the oxidation of organic matter coupled to a variety of electron acceptors just as microorganisms do in surface sediments, but at much slower rates. The technical difficulties in aseptically sampling deep subsurface sediments and the fact that microbial processes in laboratory incubations of deep subsurface material often do not mimic in situ processes frequently necessitate that microbial activity in the deep subsurface be inferred through nonmicrobiological analyses of ground water. These approaches include measurements of dissolved H2, which can predict the predominant microbially catalyzed redox reactions in aquifers, as well as geochemical and groundwater flow modeling, which can be used to estimate the rates of microbial processes. Microorganisms recovered from the deep subsurface have the potential to affect the fate of toxic organics and inorganic contaminants in groundwater. Microbial activity also greatly influences 1 the chemistry of many pristine groundwaters and contributes to such phenomena as porosity development in carbonate aquifers, accumulation of undesirably high concentrations of dissolved iron, and production of methane and hydrogen sulfide. Although the last decade has seen a dramatic increase in interest in deep subsurface microbiology, in comparison with the study of other habitats, the study of deep subsurface microbiology is still in its infancy.
Minimization of Roll Firings for Optimal Propellant Maneuvers
NASA Astrophysics Data System (ADS)
Leach, Parker C.
Attitude control of the International Space Station (ISS) is critical for operations, impacting power, communications, and thermal systems. The station uses gyroscopes and thrusters for attitude control, and reorientations are normally assisted by thrusters on docked vehicles. When the docked vehicles are unavailable, the reduction in control authority in the roll axis results in frequent jet firings and massive fuel consumption. To improve this situation, new guidance and control schemes are desired that provide control with fewer roll firings. Optimal control software was utilized to solve for potential candidates that satisfied desired conditions with the goal of minimizing total propellant. An ISS simulation too was then used to test these solutions for feasibility. After several problem reformulations, multiple candidate solutions minimizing or completely eliminating roll firings were found. Flight implementation would not only save massive amounts of fuel and thus money, but also reduce ISS wear and tear, thereby extending its lifetime.
Subsurface Hydrology: Data Integration for Properties and Processes
NASA Astrophysics Data System (ADS)
Hyndman, David W.; Day-Lewis, Frederick D.; Singha, Kamini
Groundwater is a critical resource and the PrinciPal source of drinking water for over 1.5 billion people. In 2001, the National Research Council cited as a "grand challenge" our need to understand the processes that control water movement in the subsurface. This volume faces that challenge in terms of data integration between complex, multi-scale hydrologie processes, and their links to other physical, chemical, and biological processes at multiple scales. Subsurface Hydrology: Data Integration for Properties and Processes presents the current state of the science in four aspects: • Approaches to hydrologie data integration • Data integration for characterization of hydrologie properties • Data integration for understanding hydrologie processes • Meta-analysis of current interpretations Scientists and researchers in the field, the laboratory, and the classroom will find this work an important resource in advancing our understanding of subsurface water movement.
Modeling subsurface stormflow initiation in low-relief landscapes
NASA Astrophysics Data System (ADS)
Hopp, Luisa; Vaché, Kellie B.; Rhett Jackson, C.; McDonnell, Jeffrey J.
2015-04-01
Shallow lateral subsurface flow as a runoff generating mechanism at the hillslope scale has mostly been studied in steeper terrain with typical hillside angles of 10 - 45 degrees. These studies have shown that subsurface stormflow is often initiated at the interface between a permeable upper soil layer and a lower conductivity impeding layer, e.g. a B horizon or bedrock. Many studies have identified thresholds of event size and soil moisture states that need to be exceeded before subsurface stormflow is initiated. However, subsurface stormflow generation on low-relief hillslopes has been much less studied. Here we present a modeling study that investigates the initiation of subsurface stormflow on low-relief hillslopes in the Upper Coastal Plain of South Carolina, USA. Hillslopes in this region typically have slope angles of 2-5 degrees. Topsoils are sandy, underlain by a low-conductivity sandy clay loam Bt horizon. Subsurface stormflow has only been intercepted occasionally in a 120 m long trench, and often subsurface flow was not well correlated with stream signals, suggesting a disconnect between subsurface flow on the hillslopes and stream flow. We therefore used a hydrologic model to better understand which conditions promote the initiation of subsurface flow in this landscape, addressing following questions: Is there a threshold event size and soil moisture state for producing lateral subsurface flow? What role does the spatial pattern of depth to the impeding clay layer play for subsurface stormflow dynamics? We reproduced a section of a hillslope, for which high-resolution topographic data and depth to clay measurements were available, in the hydrologic model HYDRUS-3D. Soil hydraulic parameters were based on experimentally-derived data. The threshold analysis was first performed using hourly climate data records for 2009-2010 from the study site to drive the simulation. For this period also trench measurements of subsurface flow were available. In addition, we also ran a longer-term simulation, using daily climate data for a nine year period to include more variable climate conditions in the threshold analysis. The model captured the observed subsurface flow instances very well. The threshold analysis indicated that the occurrence of subsurface stormflow uncommon, with a large proportion of the water perching above the clay layer percolating vertically into the clay layer. Event sizes of approximately 70-80 mm were required for initiating subsurface stormflow. The hourly data from 2009-2010 was subsequently used to test if the actual spatial distribution of depth to clay is a major control for the occurrence and magnitude of lateral subsurface flow. Results suggest that in this low-relief landscape also a spatially uniform mean depth to clay reproduces well the hydrologic behavior.
Water in Fire Control--Basic Training Course.
ERIC Educational Resources Information Center
Forest Service (USDA), Washington, DC.
Prepared by a team of fire control officers, the training guide is designed to help fire crewmen learn the fundamentals of water use. The entire package can be used for a complete course or individual lessons and can be adapted to specific training needs. Throughout the guide, emphasis is placed on one primary training objective, performance in…
USDA-ARS?s Scientific Manuscript database
Self-sustaining classical biological control agents offer a hope for permanent wide-area control of imported Solenopsis fire ants in the United States because escape from abundant natural enemies left behind in Argentina is a likely reason for unusually high fire ant densities in the United States. ...
77 FR 49830 - Notice of Lodging of Proposed Amendment to the Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-17
... control particulate matter emissions at its Huntingdon, Pennsylvania facility (``the Huntingdon facility'') by either shutting down coal-fired boilers, installing air emission controls on the existing unit, or converting the coal-fired boilers to natural gas-fired boilers by June 30, 2012. The Commonwealth did not...
Spatial bottom-up controls on fire likelihood vary across western North America
Sean A. Parks; Marc-Andre Parisien; Carol Miller
2012-01-01
The unique nature of landscapes has challenged our ability to make generalizations about the effects of bottom-up controls on fire regimes. For four geographically distinct fire-prone landscapes in western North America, we used a consistent simulation approach to quantify the influence of three key bottom-up factors, ignitions, fuels, and topography, on spatial...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
Fire effects in northeastern forests: red pine.
Cary Rouse
1988-01-01
Fire and red pine are closely associated. Fires can provide red pine with the mineral soil and freedom from competition it needs to become well established. Fire can also be used to control pests, increase tree growth, enhance aesthetics, and improve wildlife habitat.
NASA Astrophysics Data System (ADS)
Larson, B. I.; Houghton, J. L.; Lowell, R. P.; Farough, A.; Meile, C. D.
2015-08-01
Chemical gradients in the subsurface of mid-ocean ridge hydrothermal systems create an environment where minerals precipitate and dissolve and where chemosynthetic organisms thrive. However, owing to the lack of easy access to the subsurface, robust knowledge of the nature and extent of chemical transformations remains elusive. Here, we combine measurements of vent fluid chemistry with geochemical and transport modeling to give new insights into the under-sampled subsurface. Temperature-composition relationships from a geochemical mixing model are superimposed on the subsurface temperature distribution determined using a heat flow model to estimate the spatial distribution of fluid composition. We then estimate the distribution of Gibb's free energies of reaction beneath mid oceanic ridges and by combining flow simulations with speciation calculations estimate anhydrite deposition rates. Applied to vent endmembers observed at the fast spreading ridge at the East Pacific Rise, our results suggest that sealing times due to anhydrite formation are longer than the typical time between tectonic and magmatic events. The chemical composition of the neighboring low temperature flow indicates relatively uniform energetically favorable conditions for commonly inferred microbial processes such as methanogenesis, sulfate reduction and numerous oxidation reactions, suggesting that factors other than energy availability may control subsurface microbial biomass distribution. Thus, these model simulations complement fluid-sample datasets from surface venting and help infer the chemical distribution and transformations in subsurface flow.
DiGuiseppi, Carolyn; Roberts, Ian; Wade, Angie; Sculpher, Mark; Edwards, Phil; Godward, Catherine; Pan, Huiqi; Slater, Suzanne
2002-01-01
Objective To measure the effect of giving out free smoke alarms on rates of fires and rates of fire related injury in a deprived multiethnic urban population. Design Cluster randomised controlled trial. Setting Forty electoral wards in two boroughs of inner London, United Kingdom. Participants Primarily households including elderly people or children and households that are in housing rented from the borough council. Intervention 20 050 smoke alarms, fittings, and educational brochures distributed free and installed on request. Main outcome measures Rates of fires and related injuries during two years after the distribution; alarm ownership, installation, and function. Results Giving out free smoke alarms did not reduce injuries related to fire (rate ratio 1.3; 95% confidence interval 0.9 to 1.9), admissions to hospital and deaths (1.3; 0.7 to 2.3), or fires attended by the fire brigade (1.1; 0.96 to 1.3). Similar proportions of intervention and control households had installed alarms (36/119 (30%) v 35/109 (32%); odds ratio 0.9; 95% confidence interval 0.5 to 1.7) and working alarms (19/118 (16%) v 18/108 (17%); 0.9; 0.4 to 1.8). Conclusions Giving out free smoke alarms in a deprived, multiethnic, urban community did not reduce injuries related to fire, mostly because few alarms had been installed or were maintained. What is already known on this topicIn the United Kingdom, residential fires caused 466 deaths and 14 600 non-fatal injuries in 1999The risk of death from fire is associated with socioeconomic classOne study reported an 80% decline in hospitalisations and deaths from residential fires after free smoke alarms were distributed in an area at high risk, but these results may not apply in other settings, and evidence from randomised controlled trials is lackingWhat this study addsGiving out free smoke alarms in a multiethnic poor urban population did not reduce injuries related to fire or firesGiving smoke alarms away may be a waste of resources and of little benefit unless alarm installation and maintenance is assured PMID:12411355
Synthesis of knowledge of extreme fire behavior: volume I for fire managers
Paul A. Werth; Brian E. Potter; Craig B. Clements; Mark A. Finney; Scott L. Goodrick; Martin E. Alexander; Miguel G. Cruz; Jason A. Forthofer; Sara S. McAllister
2011-01-01
The National Wildfire Coordinating Group definition of extreme fire behavior (EFB) indicates a level of fire behavior characteristics that ordinarily precludes methods of direct control action. One or more of the following is usually involved: high rate of spread, prolific crowning/spotting, presence of fire whirls, and strong convection column. Predictability is...
STS-30 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Commander David M. Walker and Pilot Ronald J. Grabe use fire extinguishers to control blaze. Fire / security staff member Robert Fife coaches the two crewmembers during the training exercise.
Ecological effects of the Wickersham Dome fire near Fairbanks, Alaska.
L.A. Viereck; C.T. Dyrness
1979-01-01
The Wickersham Dome fire occurred in late June 1971 and burned over 6 300 hectares of predominantly black spruce forest land. Shortly after the fire was controlled, studies of the effects of the fire on various components of the biotic community were undertaken. Results reported here are mainly for the first 3 years after the fire.
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...
29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)
Code of Federal Regulations, 2011 CFR
2011-07-01
... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...
29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)
Code of Federal Regulations, 2010 CFR
2010-07-01
... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...
Method for determining depth and shape of a sub-surface conductive object
Lee, D.O.; Montoya, P.C.; Wayland, Jr.
1984-06-27
The depth to and size of an underground object may be determined by sweeping a controlled source audio magnetotelluric (CSAMT) signal and locating a peak response when the receiver spans the edge of the object. The depth of the object is one quarter wavelength in the subsurface media of the frequency of the peak. 3 figures.
2014-04-25
CAPE CANAVERAL, Fla. – Construction workers have installed the framing and some of the inner walls inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. Three rows of upper level management consoles remain. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Dimitri Gerondidakis
2014-04-25
CAPE CANAVERAL, Fla. – Construction workers have installed the framing and some of the inner walls inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. Three rows of upper level management consoles remain. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Dimitri Gerondidakis
2014-04-25
CAPE CANAVERAL, Fla. – Construction workers have installed the framing and some of the inner walls inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. Three rows of upper level management consoles remain. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Dimitri Gerondidakis
Ring magnet firing angle control
Knott, M.J.; Lewis, L.G.; Rabe, H.H.
1975-10-21
A device is provided for controlling the firing angles of thyratrons (rectifiers) in a ring magnet power supply. A phase lock loop develops a smooth ac signal of frequency equal to and in phase with the frequency of the voltage wave developed by the main generator of the power supply. A counter that counts from zero to a particular number each cycle of the main generator voltage wave is synchronized with the smooth AC signal of the phase lock loop. Gates compare the number in the counter with predetermined desired firing angles for each thyratron and with coincidence the proper thyratron is fired at the predetermined firing angle.
Satellite-based Assessment of Climate Controls on US Burned Area
NASA Technical Reports Server (NTRS)
Morton, D. C.; Collatz, G. J.; Wang, D.; Randerson, J. T.; Giglio, L.; Chen, Y.
2012-01-01
Climate regulates fire activity through the buildup and drying of fuels and the conditions for fire ignition and spread. Understanding the dynamics of contemporary climate-fire relationships at national and sub-national scales is critical to assess the likelihood of changes in future fire activity and the potential options for mitigation and adaptation. Here, we conducted the first national assessment of climate controls on US fire activity using two satellite-based estimates of monthly burned area (BA), the Global Fire Emissions Database (GFED, 1997 2010) and Monitoring Trends in Burn Severity (MTBS, 1984 2009) BA products. For each US National Climate Assessment (NCA) region, we analyzed the relationships between monthly BA and potential evaporation (PE) derived from reanalysis climate data at 0.5 resolution. US fire activity increased over the past 25 yr, with statistically significant increases in MTBS BA for entire US and the Southeast and Southwest NCA regions. Monthly PE was strongly correlated with US fire activity, yet the climate driver of PE varied regionally. Fire season temperature and shortwave radiation were the primary controls on PE and fire activity in the Alaska, while water deficit (precipitation PE) was strongly correlated with fire activity in the Plains regions and Northwest US. BA and precipitation anomalies were negatively correlated in all regions, although fuel-limited ecosystems in the Southern Plains and Southwest exhibited positive correlations with longer lead times (6 12 months). Fire season PE in creased from the 1980s 2000s, enhancing climate-driven fire risk in the southern and western US where PE-BA correlations were strongest. Spatial and temporal patterns of increasing fire season PE and BA during the 1990s 2000s highlight the potential sensitivity of US fire activity to climate change in coming decades. However, climatefire relationships at the national scale are complex, based on the diversity of fire types, ecosystems, and ignition sources within each NCA region. Changes in the seasonality or magnitude of climate anomalies are therefore unlikely to result in uniform changes in US fire activity.
NASA Astrophysics Data System (ADS)
Voytek, E.; Rushlow, C. R.; Godsey, S.; Singha, K.
2015-12-01
Shallow subsurface flow is a dominant process controlling hillslope runoff generation, soil development, and solute reaction and transport. Despite their importance, the location and geometry of flowpaths are difficult to determine. In arctic environments, shallow subsurface flowpaths are limited to a thin zone of seasonal thaw above continuous permafrost, which is traditionally assumed to mimic to surface topography. Here we use a combined approach of electrical resistivity imaging (ERI) and self-potential measurements (SP) to map shallow subsurface flowpaths in and around water tracks, drainage features common to arctic hillslopes. ERI measurements delineate thawed zones in the subsurface that control flowpaths, while SP is sensitive to groundwater flow. We find that areas of low electrical resistivity in the water tracks are deeper than manual thaw depth estimates and variations from surface topography. This finding suggests that traditional techniques significantly underestimate active layer thaw and the extent of the flowpath network on arctic hillslopes. SP measurements identify complex 3-D flowpaths in the thawed zone. Our results lay the groundwork for investigations into the seasonal dynamics, hydrologic connectivity, and climate sensitivity of spatially distributed flowpath networks on arctic hillslopes.
Robert A. Mickler; Miriam Rorig; Christopher D. Geron; Gary L. Achtemier; Andrew D. Bailey; Candice Krull; David Brownlie
2007-01-01
Wildland fuels have been accumulating in the United States during at least the past half-century due to wildland fire management practices and policies. The additional fuels contribute to intense fire behavior, increase the costs of wildland fire control, and contribute to the degradation of local and regional air quality. The management of prescribed and wildland fire...
C.J. Fettig; R.R. Borys; C.P. and Dabney
2010-01-01
We examined bark beetle responses to fire and fire surrogate treatments 2 and 4 years after the application of prescribed fire in a mixed-conifer forest in northern California. Treatments included an untreated control (C), thinning from below (T), and applications of prescribed fire (B) and T + B replicated three times in 10-ha experimental units. A total of 1,822...
Manual Fire Suppression Methods on Typical Machinery Space Spray Fires
1990-07-31
Aqueous Film Forming Foam Manuscnpt approved April 25, 1990. ( AFFF ), has been incorporated in machinery space fire protection systems to...distribution unlimited. 13. ABSTRACT (Maximum 200 words) A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foami ( AFFF ...machinery space fire protection systems to control running fuel and fuel spray fires (PKP side of TAFES), and bilge fires ( aqueous film forming foam
Syphard, Alexandra D.; Keeley, Jon E.; Brennan, Teresa J.
2011-01-01
As wildfires have increased in frequency and extent, so have the number of homes developed in the wildland-urban interface. In California, the predominant approach to mitigating fire risk is construction of fuel breaks, but there has been little empirical study of their role in controlling large fires.We constructed a spatial database of fuel breaks on the Los Padres National Forest in southern California to better understand characteristics of fuel breaks that affect the behaviour of large fires and to map where fires and fuel breaks most commonly intersect. We evaluated whether fires stopped or crossed over fuel breaks over a 28-year period and compared the outcomes with physical characteristics of the sites, weather and firefighting activities during the fire event. Many fuel breaks never intersected fires, but others intersected several, primarily in historically fire-prone areas. Fires stopped at fuel breaks 46% of the time, almost invariably owing to fire suppression activities. Firefighter access to treatments, smaller fires and longer fuel breaks were significant direct influences, and younger vegetation and fuel break maintenance indirectly improved the outcome by facilitating firefighter access. This study illustrates the importance of strategic location of fuel breaks because they have been most effective where they provided access for firefighting activities.
Keeley, J.E.; McGinnis, T.W.
2007-01-01
Following the reintroduction of fire Bromus tectorum has invaded the low elevation ponderosa pine forests in parts of Kings Canyon National Park, California. We used prescribed burns, other field manipulations, germination studies, and structural equation modelling, to investigate how fire and other factors affect the persistence of cheatgrass in these forests. Our studies show that altering burning season to coincide with seed maturation is not likely to control cheatgrass because sparse fuel loads generate low fire intensity. Increasing time between prescribed fires may inhibit cheatgrass by increasing surface fuels (both herbaceous and litter), which directly inhibit cheatgrass establishment, and by creating higher intensity fires capable of killing a much greater fraction of the seed bank. Using structural equation modelling, postfire cheatgrass dominance was shown to be most strongly controlled by the prefire cheatgrass seedbank; other factors include soil moisture, fire intensity, soil N, and duration of direct sunlight. Current fire management goals in western conifer forests are focused on restoring historical fire regimes; however, these frequent fire regimes may enhance alien plant invasion in some forest types. Where feasible, fire managers should consider the option of an appropriate compromise between reducing serious fire hazards and exacerbating alien plant invasions. ?? IAWF 2007.
Ligon, Russell A.; Siefferman, Lynn; Hill, Geoffrey E.
2011-01-01
Background Introduced organisms can alter ecosystems by disrupting natural ecological relationships. For example, red imported fire ants (Solenopsis invicta) have disrupted native arthropod communities throughout much of their introduced range. By competing for many of the same food resources as insectivorous vertebrates, fire ants also have the potential to disrupt vertebrate communities. Methodology/Principal Findings To explore the effects of fire ants on a native insectivorous vertebrate, we compared the reproductive success and strategies of eastern bluebirds (Sialia sialis) inhabiting territories with different abundances of fire ants. We also created experimental dyads of adjacent territories comprised of one territory with artificially reduced fire ant abundance (treated) and one territory that was unmanipulated (control). We found that more bluebird young fledged from treated territories than from adjacent control territories. Fire ant abundance also explained significant variation in two measures of reproductive success across the study population: number of fledglings and hatching success of second clutches. Furthermore, the likelihood of bluebird parents re-nesting in the same territory was negatively influenced by the abundance of foraging fire ants, and parents nesting in territories with experimentally reduced abundances of fire ants produced male-biased broods relative to pairs in adjacent control territories. Conclusions/Significance Introduced fire ants altered both the reproductive success (number of fledglings, hatching success) and strategies (decision to renest, offspring sex-ratio) of eastern bluebirds. These results illustrate the negative effects that invasive species can have on native biota, including species from taxonomically distant groups. PMID:21799904
O'Donnell, Jonathan A.; Harden, Jennifer W.; Manies, Kristen L.
2011-01-01
Fire is a particularly important control on the carbon (C) balance of the boreal forest, and fire-return intervals and fire severity appear to have increased since the late 1900s in North America. In addition to the immediate release of stored C to the atmosphere through organic-matter combustion, fire also modifies soil conditions, possibly affecting C exchange between terrestrial and atmospheric pools for decades after the burn. The effects of fire on ecosystem C dynamics vary across the landscape, with topographic position and soil drainage functioning as important controls. The data reported here contributed to a larger U.S. Geological Survey (USGS) study, published in the journal Ecosystems by O'Donnell and others (2009). To evaluate the effects of fire and drainage on ecosystem C dynamics, we selected sample sites within the 2003 Erickson Creek fire scar to measure CO2 fluxes and soil C inventories in burned and unburned (control) sites in both upland and lowland black spruce (Picea mariana) forests. The results of this study suggested that although fire can create soil climate conditions which are more conducive to rapid decomposition, rates of C release from soils may be constrained after fire by changes in moisture and (or) substrate quality that impede rates of decomposition. Here, we report detailed site information, methodology, and data (in spreadsheet files) from that study.
Parra, Antonio; Moreno, José M
2018-06-01
In fire-prone ecosystems, changes in rainfall after fire could differentially affect seeders and resprouters, thus leading to long-lasting impacts on the vegetation. Climate change in the Mediterranean region is projected to reduce precipitation, expand the summer drought and increase fire danger. Understanding the sensitivity to changes in rainfall during the post-fire regeneration stage is critical to anticipate the impacts of climate change on Mediterranean-type areas of the world. Here, we investigated how species differing in post-fire regeneration strategy (seeders vs resprouters) responded to rainfall changes in a Cistus-Erica shrubland of central Spain. Drought treatments were implemented using a system of automatic rainout shelters with an irrigation facility before (one season) and after (four years) burning a set of experimental plots. Treatments applied were: environmental control (natural rainfall), historical control (mimicking the long-term rainfall), moderate drought (-25% rainfall), and severe drought (-45% rainfall). Plant demography and vigour (main woody shrubs), as well as abundance (shrubs and herbs) were monitored during the first four years after fire. The first post-fire year was the key period for the recovery of seeders (Cistus ladanifer and Rosmarinus officinalis), and their recruitment, cover and size significantly decreased with drought. However, density four years after fire was larger than unburned and it was significantly correlated with emergence during the first year, indicating that population controls were more on emergence than on establishment. In contrast, resprouters (Erica arborea, Erica scoparia and Phillyrea angustifolia) were hardly affected by drought. Plant community dynamics in the burned control plots progressively converged with the unburned ones, while that in the drought-treated plots lagged behind them, maintaining a higher cover, richness and diversity of herbs. This post-fire "herbalization" due to drought might facilitate an untimely fire, before seeders would reach sexual maturity, which could have major implications for the maintenance of the community. Copyright © 2018 Elsevier B.V. All rights reserved.
CONTROLLING MULTIPLE EMISSIONS FROM COAL-FIRED POWER PLANTS
The paper presents and analyzes nine existing and novel control technologies designed to achieve multipollutant emissions reductions. It provides an evaluation of multipollutant emission control technologies that are potentially available for coal-fired power plants of 25 MW capa...
Status of NO sub x control for coal-fired power plants
NASA Technical Reports Server (NTRS)
Teixeira, D. P.
1978-01-01
The status of technologies for controlling emissions of oxides of nitrogen (NOx) from coal-fired power plants is reviewed. A discussion of current technology as well as future NOx control approaches is presented. Advanced combustion approaches are included as well as post-combustion alternatives such as catalytic and noncatalytic ammonia-bases systems and wet scrubbing. Special emphasis is given to unresolved development issues as they relate to practical applications on coal-fired power plants.
15. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, AND SECTIONS." ...
15. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, AND SECTIONS." Specifications No. ENG-04-353-57-75; Drawing No. AF-60-09-15; sheet 40 of 96; D.O. Series No. AF 1394/60, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 5296 Rev. A, Date: 11/17/59. - Edwards Air Force Base, South Base Sled Track, Firing Control Blockhouse, South of Sled Track at east end, Lancaster, Los Angeles County, CA
New Technologies and Materials for Enhanced Damage and Fire Tolerance of Naval Vessels
2011-02-01
have already been used on naval vessels. However, their incorporation into fire and damage control systems has not progressed past the prototype...have an important role to play in enhancing fire suppression capabilities onboard ships. One is ventilation control . It can be used to isolate a...complicated than those for a dedicated system. Positive pressure ventilation and the use of the ship board HVAC trunking to control the spread of smoke
Contribution from motor unit firing adaptations and muscle co-activation during fatigue.
Contessa, Paola; Letizi, John; De Luca, Gianluca; Kline, Joshua C
2018-03-14
The control of motor unit firing behavior during fatigue is still debated in the literature. Most studies agree that the central nervous system increases the excitation to the motoneuron pool to compensate for decreased force contributions of individual motor units and sustain muscle force output during fatigue. However, some studies claim that motor units may decrease their firing rates despite increased excitation, contradicting the direct relationship between firing rates and excitation that governs the voluntary control of motor units. To investigate whether the control of motor units in fact changes with fatigue, we measured motor unit firing behavior during repeated contractions of the first dorsal interosseous (FDI) muscle while concurrently monitoring the activation of surrounding muscles - including the flexor carpi radialis, extensor carpi radialis, and pronator teres. Across all subjects, we observed an overall increase in FDI activation and motor unit firing rates by the end of the fatigue task. However, in some subjects we observed increases in FDI activation and motor unit firing rates only during the initial phase of the fatigue task, followed by subsequent decreases during the late phase of the fatigue task while the co-activation of surrounding muscles increased. These findings indicate that the strategy for sustaining force output may occasionally change leading to increases in the relative activation of surrounding muscles while the excitation to the fatiguing muscle decreases. Importantly, irrespective of changes in the strategy for sustaining force output, the control properties regulating motor unit firing behavior remain unchanged during fatigue.
Retrofitted coal-fired firetube boiler and method employed therewith
Wagoner, C.L.; Foote, J.P.
1995-07-04
A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler are disclosed. The converted boiler includes a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones. 19 figs.
Ballesteros, Michael F; Jackson, Mark L; Martin, Maurice W
2005-01-01
To address residential fires and related injuries, the Centers for Disease Control and Prevention funds state health departments to deliver a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in high-risk homes in 16 states. This program involves recruiting local communities and community partners, hiring a local coordinator, canvassing neighborhood homes, installing long-lasting lithium-powered smoke alarms, and providing general fire safety education and 6-month follow-up to determine alarm functionality. Local fire departments are vital community partners in delivering this program. Since the program's inception, more than 212,000 smoke alarms have been installed in more than 126,000 high-risk homes. Additionally, approximately 610 lives have potentially been saved as a result of a program alarm that provided early warning to a dangerous fire incident.
Meteorological Controls on Biomass Burning During Santa Ana Events in Southern California
NASA Technical Reports Server (NTRS)
Veraverbeke, Sander; Capps, Scott; Hook, Simon J.; Randerson, James T.; Jin, Yufang; Hall, Alex
2013-01-01
Fires occurring during Santa Ana (SA) events in southern California are driven by extreme fire weather characterized by high temperatures, low humidities, and high wind speeds. We studied the controls on burned area and carbon emissions during two intensive SA burning periods in 2003 and 2007. We therefore used remote sensing data in parallel with fire weather simulations of the Weather and Regional Forecast model. Total carbon emissions were approximately 1800 gigagrams in 2003 and 900 gigagrams in 2007, based on a daily burned area and a fire emission model that accounted for spatial variability in fuel loads and combustion completeness. On a regional scale, relatively strong positive correlations were found between the daily Fosberg fire weather index and burned area/emissions (probability is less than 0.01). Our analysis provides a quantitative assessment of relationships between fire activity and weather during severe SA fires in southern California.
Diadema, Katia; Médail, Frédéric; Bretagnolle, François
2007-09-01
We examine the effects of fire and/or surrounding vegetation cover on demographic stage densities and plant performance for a rare endemic geophyte, Acis nicaeensis (Alliaceae), in Mediterranean xerophytic grasslands of the 'Alpes-Maritimes' French 'département', through sampling plots in unburned and burned treatments. Fire increases density of flowering individuals and seedling emergence, as well as clump densities and number of individuals per clump, per limiting vegetation height and cover, and increasing bare soil cover. In contrast, fire has no effect on reproductive success. Nevertheless, two growing seasons after fire, all parameters of demographic stages and plant performance do not significantly differ between the two treatments. Small-scale fire is beneficial for the regeneration of this threatened geophyte at a short-time scale. In this context, a conservation planning with small and controlled fires could maintain the regeneration window for populations of rare Mediterranean geophytes.
Fire control method and analytical model for large liquid hydrocarbon pool fires
NASA Technical Reports Server (NTRS)
Fenton, D. L.
1986-01-01
The dominate parameter governing the behavior of a liquid hydrocarbon (JP-5) pool fire is wind speed. The most effective method of controlling wind speed in the vicinity of a large circular (10 m dia.) pool fire is a set of concentric screens located outside the perimeter. Because detailed behavior of the pool fire structure within one pool fire diameter is unknown, an analytical model supported by careful experiments is under development. As a first step toward this development, a regional pool fire model was constructed for the no-wind condition consisting of three zones -- liquid fuel, combustion, and plume -- where the predicted variables are mass burning rate and characteristic temperatures of the combustion and plume zones. This zone pool fire model can be modified to incorporate plume bending by wind, radiation absorption by soot particles, and a different ambient air flow entrainment rate. Results from the zone model are given for a pool diameter of 1.3 m and are found to reproduce values in the literature.
CONTROL OF NOX EMISSIONS FROM U.S. COAL-FIRED ELECTRIC UTILITY BOILERS
The paper discusses the control of nitrogen oxide (NOx) emissions from U.S. coal-fired electric utility boilers. (NOTE: In general, NOx control technologies are categorized as being either primary or secondary control technologies. Primary technologies reduce the amount of NOx pr...
Acute oral toxicities of wildland fire control chemicals to birds
Vyas, N.B.; Spann, J.W.; Hill, E.F.
2009-01-01
Wildland fire control chemicals are released into the environment by aerial and ground applications to manage rangeland, grassland, and forest fires. Acute oral 24 h median lethal dosages (LD50) for three fire retardants (Fire-Trol GTS-R?, Phos-Chek D-75F?, and Fire-Trol LCG-R?) and two Class A fire suppressant foams (Silv-Ex? and Phos-Chek WD881?) were estimated for northern bobwhites, Colinus virginianus, American kestrels, Falco sparverius, and red-winged blackbirds, Agelaius phoeniceus. The LD50s of all chemicals for the bobwhites and red-winged blackbirds and for kestrels dosed with Phos-Chek WD881? and Silv-Ex? were above the predetermined 2000 mg chemical/kg body mass regulatory limit criteria for acute oral toxicity. The LD50s were not quantifiable for kestrels dosed with Fire-Trol GTS-R?, Phos-Chek D-75F?, and Fire-Trol LCG-R? because of the number of birds which regurgitated the dosage. These chemicals appear to be of comparatively low order of acute oral toxicity to the avian species tested.
DiGuiseppi, Carolyn; Roberts, Ian; Wade, Angie; Sculpher, Mark; Edwards, Phil; Godward, Catherine; Pan, Huiqi; Slater, Suzanne
2002-11-02
To measure the effect of giving out free smoke alarms on rates of fires and rates of fire related injury in a deprived multiethnic urban population. Cluster randomised controlled trial. Forty electoral wards in two boroughs of inner London, United Kingdom. Primarily households including elderly people or children and households that are in housing rented from the borough council. 20 050 smoke alarms, fittings, and educational brochures distributed free and installed on request. Rates of fires and related injuries during two years after the distribution; alarm ownership, installation, and function. Giving out free smoke alarms did not reduce injuries related to fire (rate ratio 1.3; 95% confidence interval 0.9 to 1.9), admissions to hospital and deaths (1.3; 0.7 to 2.3), or fires attended by the fire brigade (1.1; 0.96 to 1.3). Similar proportions of intervention and control households had installed alarms (36/119 (30%) v 35/109 (32%); odds ratio 0.9; 95% confidence interval 0.5 to 1.7) and working alarms (19/118 (16%) v 18/108 (17%); 0.9; 0.4 to 1.8). Giving out free smoke alarms in a deprived, multiethnic, urban community did not reduce injuries related to fire, mostly because few alarms had been installed or were maintained.
2014-04-03
CAPE CANAVERAL, Fla. – The Mobile Launcher is visible through a window inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
Fire management of California shrubland landscapes
Keeley, Jon E.
2002-01-01
Fire management of California shrublands has been heavily influenced by policies designed for coniferous forests, however, fire suppression has not effectively excluded fire from chaparral and coastal sage scrub landscapes and catastrophic wildfires are not the result of unnatural fuel accumulation. There is no evidence that prescribed burning in these shrublands provides any resource benefit and in some areas may negatively impact shrublands by increasing fire frequency. Therefore, fire hazard reduction is the primary justification for prescription burning, but it is doubtful that rotational burning to create landscape age mosaics is a cost effective method of controlling catastrophic wildfires. There are problems with prescription burning in this crown-fire ecosystem that are not shared by forests with a natural surface-fire regime. Prescription weather conditions preclude burning at rotation intervals sufficient to effect the control of fires ignited under severe weather conditions. Fire management should focus on strategic placement of prescription burns to both insure the most efficient fire hazard reduction and to minimize the amount of landscape exposed to unnaturally high fire frequency. A major contributor to increased fire suppression costs and increased loss of property and lives is the continued urban sprawl into wildlands naturally subjected to high intensity crown fires. Differences in shrubland fire history suggest there may be a need for different fire management tactics between central coastal and southern California. Much less is known about shrubland fire history in the Sierra Nevada foothills and interior North Coast Ranges, and thus it would be prudent to not transfer these ideas too broadly across the range of chaparral until we have a clearer understanding of the extent of regional variation in shrubland fire regimes.
Fire management of California shrubland landscapes.
Keeley, Jon E
2002-03-01
Fire management of California shrublands has been heavily influenced by policies designed for coniferous forests, however, fire suppression has not effectively excluded fire from chaparral and coastal sage scrub landscapes and catastrophic wildfires are not the result of unnatural fuel accumulation. There is no evidence that prescribed burning in these shrublands provides any resource benefit and in some areas may negatively impact shrublands by increasing fire frequency. Therefore, fire hazard reduction is the primary justification for prescription burning, but it is doubtful that rotational burning to create landscape age mosaics is a cost effective method of controlling catastrophic wildfires. There are problems with prescription burning in this crown-fire ecosystem that are not shared by forests with a natural surface-fire regime. Prescription weather conditions preclude burning at rotation intervals sufficient to effect the control of fires ignited under severe weather conditions. Fire management should focus on strategic placement of prescription burns to both insure the most efficient fire hazard reduction and to minimize the amount of landscape exposed to unnaturally high fire frequency. A major contributor to increased fire suppression costs and increased loss of property and lives is the continued urban sprawl into wildlands naturally subjected to high intensity crown fires. Differences in shrubland fire history suggest there may be a need for different fire management tactics between central coastal and southern California. Much less is known about shrubland fire history in the Sierra Nevada foothills and interior North Coast Ranges, and thus it would be prudent to not transfer these ideas too broadly across the range of chaparral until we have a clearer understanding of the extent of regional variation in shrubland fire regimes.
Risk factors for rural residential fires.
Allareddy, Veerasathpurush; Peek-Asa, Corinne; Yang, Jingzhen; Zwerling, Craig
2007-01-01
Rural households report high fire-related mortality and injury rates, but few studies have examined the risk factors for fires. This study aims to identify occupant and household characteristics that are associated with residential fires in a rural cohort. Of 1,005 households contacted in a single rural county, 691 (68.8%) agreed to participate. One household with missing information on a reported fire was excluded from the analysis. We used logistic regression to examine the independent association of occupant and household characteristics with reported fires, controlling for years lived in the residence. We also examined the association between the occurrence of previous fires and the adoption of safety measures. A total of 78 (11.3%) households reported a residential fire. Occupant characteristics that were associated with significantly higher odds of reported fires included the presence of an occupant with alcohol problems (OR = 1.82, 95% CI = 1.01-3.28) and being married (OR = 2.11, 95% CI = 1.14-3.91). Rural farm households were associated with significantly higher odds (OR = 1.72, 95% CI = 1.01-2.93) of reporting a fire when compared to residences in towns, after controlling for all other occupant and household characteristics. The presence of a fire extinguisher (OR = 2.00, 95% CI = 1.10-3.64) was the only fire safety measure that had a statistically significant association with reported fire. Rural farm households report higher incidences of fire when compared to households located in towns. Experiencing a fire is not associated with an increased likelihood of adopting safety measures to prevent injuries once a fire has started.
Large-Scale Controls and Characteristics of Fire Activity in Central Chile, 2001-2015
NASA Astrophysics Data System (ADS)
McWethy, D. B.; Pauchard, A.; García, R.; Holz, A.; González, M.; Veblen, T. T.; Stahl, J.
2016-12-01
In recent decades, fire activity has increased in many ecosystems worldwide, even where fuel conditions and natural ignitions historically limited fire activity, and this increase begs questions of whether climate change, land-use change, and/or altered vegetation are responsible. Increased frequency of large fires in these settings has been attributed to drier-than-average summers and longer fire seasons as well as fuel accumulation related to ENSO events, raising concerns about the trajectory of post-fire vegetation dynamics and future fire regimes. In temperate and Mediterranean forests of central Chile, recent large fires associated with altered ecosystems, climate variability and land-use change highlight the risk and hazard of increasing fire activity yet the causes and consequences are poorly understood. To better understand characteristics of recent fire activity, key drivers of fire occurrence and the spatial probability of wildfire we examined the relationship between fire activity derived from MODIS satellite imagery and biophysical, land-cover and land-use variables. The probability of fire occurrence and annual area burned was best predicted by seasonal precipitation, annual temperature and land cover type. The likelihood of fire occurrence was greatest in Matorral shrublands, agricultural lands (including pasture lands) and Pinus and Eucalyptus plantations, highlighting the importance of vegetation type and fuel flammability as a critical control on fire activity. Our results suggest that land-use change responsible for the widespread presence of highly flammable vegetation and projections for continued warming and drying will likely combine to promote the occurrence of large fires in central Chile in the future.
W. J. Massman; J. M. Frank; S. M. Massman; W. D. Shepperd
2003-01-01
Natural and prescribed fires play an important role in managing and maintaining most ecosystems in the western United States. The high soil temperatures associated with fire influence forests and their ability to regenerate after a fire by altering soil properties and soil chemistry and by killing microbes, plant roots, and seeds. Because prescribed fire is frequently...
Economic benefits of reducing fire-related sediment in southwestern fire-prone ecosystems
John Loomis; Pete Wohlgemuth; Armando González-Cabán; Don English
2003-01-01
A multiple regression analysis of fire interval and resulting sediment yield (controlling for relief ratio, rainfall, etc.) indicates that reducing the fire interval from the current average 22 years to a prescribed fire interval of 5 years would reduce sediment yield by 2 million cubic meters in the 86.2 square kilometer southern California watershed adjacent to and...
Interagency wilderness fire management
Jim Desmond
1995-01-01
Wilderness fire managers are often confronted with natural fire ignitions that start and/or burn near an adjoining agencyâs wilderness area boundary. Management strategies for prescribed natural fires (PNF) are often developed using the adjoining agencyâs wilderness boundary as the maximum allowable perimeter (control line) for the PNF. When this occurs, fireâs natural...
Paul A. Werth; Brian E. Potter; Martin E. Alexander; Craig B. Clements; Miguel G. Cruz; Mark A. Finney; Jason M. Forthofer; Scott L. Goodrick; Chad Hoffman; W. Matt Jolly; Sara S. McAllister; Roger D. Ottmar; Russell A. Parsons
2016-01-01
The National Wildfire Coordinating Groupâs definition of extreme fire behavior indicates a level of fire behavior characteristics that ordinarily precludes methods of direct control action. One or more of the following is usually involved: high rate of spread, prolific crowning/ spotting, presence of fire whirls, and strong convection column. Predictability is...
Swetnam, Thomas W.; Farella, Joshua; Roos, Christopher I.; Liebmann, Matthew J.; Falk, Donald A.; Allen, Craig D.
2016-01-01
Interannual climate variations have been important drivers of wildfire occurrence in ponderosa pine forests across western North America for at least 400 years, but at finer scales of mountain ranges and landscapes human land uses sometimes over-rode climate influences. We reconstruct and analyse effects of high human population densities in forests of the Jemez Mountains, New Mexico from ca 1300 CE to Present. Prior to the 1680 Pueblo Revolt, human land uses reduced the occurrence of widespread fires while simultaneously adding more ignitions resulting in many small-extent fires. During the 18th and 19th centuries, wet/dry oscillations and their effects on fuels dynamics controlled widespread fire occurrence. In the late 19th century, intensive livestock grazing disrupted fuels continuity and fire spread and then active fire suppression maintained the absence of widespread surface fires during most of the 20th century. The abundance and continuity of fuels is the most important controlling variable in fire regimes of these semi-arid forests. Reduction of widespread fires owing to reduction of fuel continuity emerges as a hallmark of extensive human impacts on past forests and fire regimes.
How does fire affect longleaf pine roots carbohydrates, foliar nutrients, and sapling growth?
Eric A. Kuehler; Marry Anne Sword Sayer; C. Dan Andries
2006-01-01
In central Louisiana, we conducted a prescribed-fire study in a 5-year-old longleaf pine (Pinus palustris P. Mill.) stand to evaluate the effects of fire on fine-root (2- to 5-mm diameter) carbohydrates, dormant season foliar nutrients, and sapling growth. Control, burn, and nonburned vegetation control treatments were studied using a randomized...
Systematic control of nonmetallic materials for improved fire safety
NASA Technical Reports Server (NTRS)
1972-01-01
The elements of a systematic fire safety program are summarized and consist of fire safety criteria, design considerations, testing of materials, development of nonmetallic materials, nonmetallic materials information systems, design reviews, and change control. The system described in this report was developed for the Apollo spacecraft. The system can, however, be tailored to many industrial, commercial, and military activities.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This document presents an outline for a 135-hour course designed to familiarize the student with manipulative skills and theoretical knowledge concerning aircraft instrument systems like major flight and engine instruments; fire protection and fire fighting systems; warning systems and navigation systems; aircraft cabin control systems, such as…
Fire Play: ICCARUS--Intelligent Command and Control, Acquisition and Review Using Simulation
ERIC Educational Resources Information Center
Powell, James; Wright, Theo; Newland, Paul; Creed, Chris; Logan, Brian
2008-01-01
Is it possible to educate a fire officer to deal intelligently with the command and control of a major fire event he will never have experienced? The authors of this paper believe there is, and present here just one solution to this training challenge. It involves the development of an intelligent simulation based upon computer managed interactive…
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact-resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact-resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Modeling Subsurface Behavior at the System Level: Considerations and a Path Forward
NASA Astrophysics Data System (ADS)
Geesey, G.
2005-12-01
The subsurface is an obscure but essential resource to life on Earth. It is an important region for carbon production and sequestration, a source and reservoir for energy, minerals and metals and potable water. There is a growing need to better understand subsurface possesses that control the exploitation and security of these resources. Our best models often fail to predict these processes at the field scale because of limited understanding of 1) the processes and the controlling parameters, 2) how processes are coupled at the field scale 3) geological heterogeneities that control hydrological, geochemical and microbiological processes at the field scale and 4) lack of data sets to calibrate and validate numerical models. There is a need for experimental data obtained at scales larger than those obtained at the laboratory bench that take into account the influence of hydrodynamics, geochemical reactions including complexation and chelation/adsorption/precipitation/ion exchange/oxidation-reduction/colloid formation and dissolution, and reactions of microbial origin. Furthermore, the coupling of each of these processes and reactions needs to be evaluated experimentally at a scale that produces data that can be used to calibrate numerical models so that they accurately describe field scale system behavior. Establishing the relevant experimental scale for collection of data from coupled processes remains a challenge and will likely be process-dependent and involve iterations of experimentation and data collection at different intermediate scales until the models calibrated with the appropriate date sets achieve an acceptable level of performance. Assuming that the geophysicists will soon develop technologies to define geological heterogeneities over a wide range of scales in the subsurface, geochemists need to continue to develop techniques to remotely measure abiotic reactions, while geomicrobiologists need to continue their development of complementary technologies to remotely measure microbial community parameters that define their key functions at a scale that accurately reflects their role in large scale subsurface system behavior. The practical questions that geomicrobiologist must answer in the short term are: 1) What is known about the activities of the dominant microbial populations or those of their closest relatives? 2) Which of these activities is likely to dominate under in situ conditions? In the process of answering these questions, researchers will obtain answers to questions of a more fundamental nature such as 1) How deep does "active" life extend below the surface of the seafloor and terrestrial subsurface? 2) How are electrons exchanged between microbial cells and solid phase minerals? 3) What is the metabolic state and mechanism of survival of "inactive" life forms in the subsurface? 4) What can genomes of life forms trapped in geological material tell us about evolution of life that current methods cannot? The subsurface environment represents a challenging environment to understand and model. As the need to understand subsurface processes increases and the technologies to characterize them become available, modeling subsurface behavior will approach the level of sophistication of models used today to predict behavior of other large scale systems such as the oceans.
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...
14 CFR 23.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 23.1197 Section... test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will be discharged, under established fire control procedures...
14 CFR 25.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 25.1197 Section... test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will be discharged, under established fire control procedures...
MERCURY CONTROL IN MUNICIPAL WASTE COMBUSTORS AND COAL-FIRED UTILITIES
Control of mercury (Hg) emissions from municipal waste combustors (MWCs) and coal-fired utilities has attracted attention due to current and potential regulations. Among several techniques evaluated for Hg control, dry sorbent injection (primarily injection of activated carbon) h...
Revill, Ann L; Fuglevand, Andrew J
2017-01-01
Motor neurons are the output neurons of the central nervous system and are responsible for controlling muscle contraction. When initially activated during voluntary contraction, firing rates of motor neurons increase steeply but then level out at modest rates. Activation of an intrinsic source of excitatory current at recruitment onset may underlie the initial steep increase in firing rate in motor neurons. We attempted to disable this intrinsic excitatory current by artificially activating an inhibitory reflex. When motor neuron activity was recorded while the inhibitory reflex was engaged, firing rates no longer increased steeply, suggesting that the intrinsic excitatory current was probably responsible for the initial sharp rise in motor neuron firing rate. During graded isometric contractions, motor unit (MU) firing rates increase steeply upon recruitment but then level off at modest rates even though muscle force continues to increase. The mechanisms underlying such firing behaviour are not known although activation of persistent inward currents (PICs) might be involved. PICs are intrinsic, voltage-dependent currents that activate strongly when motor neurons (MNs) are first recruited. Such activation might cause a sharp escalation in depolarizing current and underlie the steep initial rise in MU firing rate. Because PICs can be disabled with synaptic inhibition, we hypothesized that artificial activation of an inhibitory pathway might curb this initial steep rise in firing rate. To test this, human subjects performed slow triangular ramp contractions of the ankle dorsiflexors in the absence and presence of tonic synaptic inhibition delivered to tibialis anterior (TA) MNs by sural nerve stimulation. Firing rate profiles (expressed as a function of contraction force) of TA MUs recorded during these tasks were compared for control and stimulation conditions. Under control conditions, during the ascending phase of the triangular contractions, 93% of the firing rate profiles were best fitted by rising exponential functions. With stimulation, however, firing rate profiles were best fitted with linear functions or with less steeply rising exponentials. Firing rate profiles for the descending phases of the contractions were best fitted with linear functions for both control and stimulation conditions. These results seem consistent with the idea that PICs contribute to non-linear firing rate profiles during ascending but not descending phases of contractions. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
NASA Technical Reports Server (NTRS)
Carhart, Homer W.
1987-01-01
It is argued that fires are dependent primarily on the concentration of oxygen, whereas life is dependent on the partial pressure of oxygen. It follows that in an inhabited capsule it should be possible to exercise a certain amount of willful control over fire and still maintain habitability by proper selection of the composition of the atmosphere. This leads to two concepts in the control of fires in confined spaces by controlling atmospheric composition: the first, to lower the overall potential hazard by maintaining the percent of oxygen in the capsule below that of air, and second, to provide for the emergency extinguishment of a fire by sudden flooding with nitrogen. Several relevant charts and graphs are presented.
FUNDAMENTAL SCIENCE AND ENGINEERING OF MERCURY CONTROL IN COAL-FIRED POWER PLANTS
The paper discusses the existing knowledge base applicable to mercury (Hg) control in coal-fired boilers and outlines the gaps in knowledge that can be filled by experimentation and data gathering. Mercury can be controlled by existing air pollution control devices or by retrofit...
Swetnam, Thomas W; Farella, Joshua; Roos, Christopher I; Liebmann, Matthew J; Falk, Donald A; Allen, Craig D
2016-06-05
Interannual climate variations have been important drivers of wildfire occurrence in ponderosa pine forests across western North America for at least 400 years, but at finer scales of mountain ranges and landscapes human land uses sometimes over-rode climate influences. We reconstruct and analyse effects of high human population densities in forests of the Jemez Mountains, New Mexico from ca 1300 CE to Present. Prior to the 1680 Pueblo Revolt, human land uses reduced the occurrence of widespread fires while simultaneously adding more ignitions resulting in many small-extent fires. During the 18th and 19th centuries, wet/dry oscillations and their effects on fuels dynamics controlled widespread fire occurrence. In the late 19th century, intensive livestock grazing disrupted fuels continuity and fire spread and then active fire suppression maintained the absence of widespread surface fires during most of the 20th century. The abundance and continuity of fuels is the most important controlling variable in fire regimes of these semi-arid forests. Reduction of widespread fires owing to reduction of fuel continuity emerges as a hallmark of extensive human impacts on past forests and fire regimes.This article is part of the themed issue 'The interaction of fire and mankind'. © 2016 The Authors.
Farella, Joshua; Liebmann, Matthew J.; Falk, Donald A.; Allen, Craig D.
2016-01-01
Interannual climate variations have been important drivers of wildfire occurrence in ponderosa pine forests across western North America for at least 400 years, but at finer scales of mountain ranges and landscapes human land uses sometimes over-rode climate influences. We reconstruct and analyse effects of high human population densities in forests of the Jemez Mountains, New Mexico from ca 1300 CE to Present. Prior to the 1680 Pueblo Revolt, human land uses reduced the occurrence of widespread fires while simultaneously adding more ignitions resulting in many small-extent fires. During the 18th and 19th centuries, wet/dry oscillations and their effects on fuels dynamics controlled widespread fire occurrence. In the late 19th century, intensive livestock grazing disrupted fuels continuity and fire spread and then active fire suppression maintained the absence of widespread surface fires during most of the 20th century. The abundance and continuity of fuels is the most important controlling variable in fire regimes of these semi-arid forests. Reduction of widespread fires owing to reduction of fuel continuity emerges as a hallmark of extensive human impacts on past forests and fire regimes. This article is part of the themed issue ‘The interaction of fire and mankind’. PMID:27216525
NASA Technical Reports Server (NTRS)
Kaszubowski, M.; Raney, J. P.
1986-01-01
A study was conducted to determine the dynamic effects of firing the orbiter primary reaction control jets during assembly of protoflight space station structure. Maximum longeron compressive load was calculated as a function of jet pulse time length, number of jet pulses, and total torque imposed by the reaction control jets. The study shows that it is possible to fire selected jets to achieve a pitch maneuver without causing failure of the attached structure.
14. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, ELEVATIONS, SECTION, ...
14. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, ELEVATIONS, SECTION, DETAIL AND SCHED." Specifications No. ENG-04-353-57-75; Drawing No. AF-60-09-15; sheet 21 of 96; D.O. Series No. AF 1394/39, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 5296 Rev. A, Date: 11/17/59. - Edwards Air Force Base, South Base Sled Track, Firing Control Blockhouse, South of Sled Track at east end, Lancaster, Los Angeles County, CA
Yang, Guang; Shu, Li-Fu; Di, Xue-Ying
2012-11-01
By using Delta and WGEN downscaling methods and Canadian Forest Fire Weather Index, this paper analyzed the variation characteristics of summer fire in Great Xing' an Mountains forest region of Heilongjiang Province in 1966-2010, estimated the change trends of the summer fire danger in 2010-2099, compared the differences of the forest fire in summer, spring, and autumn, and proposed the prevention and control strategies of the summer fire based on the fire environment. Under the background of climate warming, the summer forest fire in the region in 2000-2010 showed a high incidence trend. In foreseeable future, the summer forest fire across the region in 2010-2099, as compared to that in the baseline period 1961-1990, would be increased by 34%, and the increment would be obviously greater than that of spring and autumn fire. Relative to that in 1961-1990, the summer fire in 2010-2099 under both SRES A2a and SRES B2a scenarios would have an increasing trend, and, with the lapse of time, the trend would be more evident, and the area with high summer fire would become wider and wider. Under the scenario of SRES A2a, the summer fire by the end of the 21st century would be doubled, as compared to that in 1961-1990, and the area with high summer fire would be across the region. In the characteristics of fire source, attributes of forest fuel, and fire weather conditions, the summer forest fire was different from the spring and autumn forest fire, and thus, the management of fire source and forest fuel load as well as the forest fire forecast (mid-long term forecast in particular) in the region should be strengthened to control the summer forest fire.
Luoma, James A.; Severson, Todd J.
2016-01-01
The efficacy of whole water column and subsurface applications of the biopesticide Zequanox®, a commercially prepared spray-dried powder formulation of Pseudomonas fluorescens (strain CL145A), were evaluated for controlling zebra mussels (Dreissena polymorpha) within 27-m2 enclosures in Lake Minnetonka (Deephaven, Minnesota). Five treatments consisting of (1) two whole water column Zequanox applications, (2) two subsurface Zequanox applications, and (3) an untreated control were completed on each of three independent treatment days during September 2014. The two types of samplers used in the study were (1) type 1 samplers, which were custom built multi-plate samplers (wood, perforated aluminum, and tile substrates) that were placed into Robinson’s Bay in June of 2013 to allow for natural colonization by zebra mussels, and (2) type 2 samplers, which consisted of zebra mussels adhering to perforated aluminum trays that were placed into mesh containment bags. One day prior to treatment, three individual samplers of each type were distributed to test enclosures and exposed to a randomly assigned treatment. Sampling to determine the zebra mussel biomass adhering to type 1 samplers and the survival assessments for zebra mussels contained in type 2 samplers were completed ~40 days after exposure. The zebra mussel biomass adhering to type 1 samplers and the survival of zebra mussels contained in type 2 samplers were significantly less in groups treated with the highest Zequanox concentrations and in groups that received whole water column applications than comparable groups treated with lower Zequanox concentrations and subsurface applications. However, standardization of biomass and survival results to the amount of Zequanox applied showed that the lower concentrations and subsurface applications were more cost efficient, with respect to product used, at reducing zebra mussel biomass and for inducing zebra mussel mortality. Although the subsurface application methods and lower treatment concentrations were more cost efficient, biological significance and management goals should be evaluated prior to selecting the application method. Development and refinement of additional application techniques may improve the utility of the subsurface Zequanox applications.
Untangling the biological contributions to soil stability in semiarid shrublands
Chaudhary, V. Bala; Bowker, Matthew A.; O'Dell, Thomas E.; Grace, James B.; Redman, Andrea E.; Rillig, Matthias C.; Johnson, Nancy C.
2009-01-01
Communities of plants, biological soil crusts (BSCs), and arbuscular mycorrhizal (AM) fungi are known to influence soil stability individually, but their relative contributions, interactions, and combined effects are not well understood, particularly in arid and semiarid ecosystems. In a landscape-scale field study we quantified plant, BSC, and AM fungal communities at 216 locations along a gradient of soil stability levels in southern Utah, USA. We used multivariate modeling to examine the relative influences of plants, BSCs, and AM fungi on surface and subsurface stability in a semiarid shrubland landscape. Models were found to be congruent with the data and explained 35% of the variation in surface stability and 54% of the variation in subsurface stability. The results support several tentative conclusions. While BSCs, plants, and AM fungi all contribute to surface stability, only plants and AM fungi contribute to subsurface stability. In both surface and subsurface models, the strongest contributions to soil stability are made by biological components of the system. Biological soil crust cover was found to have the strongest direct effect on surface soil stability (0.60; controlling for other factors). Surprisingly, AM fungi appeared to influence surface soil stability (0.37), even though they are not generally considered to exist in the top few millimeters of the soil. In the subsurface model, plant cover appeared to have the strongest direct influence on soil stability (0.42); in both models, results indicate that plant cover influences soil stability both directly (controlling for other factors) and indirectly through influences on other organisms. Soil organic matter was not found to have a direct contribution to surface or subsurface stability in this system. The relative influence of AM fungi on soil stability in these semiarid shrublands was similar to that reported for a mesic tallgrass prairie. Estimates of effects that BSCs, plants, and AM fungi have on soil stability in these models are used to suggest the relative amounts of resources that erosion control practitioners should devote to promoting these communities. This study highlights the need for system approaches in combating erosion, soil degradation, and arid-land desertification.
Hierarchical control of motor units in voluntary contractions.
De Luca, Carlo J; Contessa, Paola
2012-01-01
For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The "firing rate spectrum" presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units-both characteristics being well suited for generating and sustaining force during the fight-or-flight response.
Hierarchical control of motor units in voluntary contractions
Contessa, Paola
2012-01-01
For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The “firing rate spectrum” presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units—both characteristics being well suited for generating and sustaining force during the fight-or-flight response. PMID:21975447
Wetland fire remote sensing research--The Greater Everglades example
Jones, John W.
2012-01-01
Fire is a major factor in the Everglades ecosystem. For thousands of years, lightning-strike fires from summer thunderstorms have helped create and maintain a dynamic landscape suited both to withstand fire and recover quickly in the wake of frequent fires. Today, managers in the Everglades National Park are implementing controlled burns to promote healthy, sustainable vegetation patterns and ecosystem functions. The U.S. Geological Survey (USGS) is using remote sensing to improve fire-management databases in the Everglades, gain insights into post-fire land-cover dynamics, and develop spatially and temporally explicit fire-scar data for habitat and hydrologic modeling.
Fire Alters Emergence of Invasive Plant Species from Soil Surface-Deposited Seeds
USDA-ARS?s Scientific Manuscript database
1. Fire is recognized as an important process controlling ecosystem structure and function. Restoration of fire regimes is complicated by global concerns about exotic plants invasions, yet little is known of how the two may interact. Characterizing relationships between fire conditions and the vi...
The Wildland/Urban Interface in 2025
Gary O. Tokle
1987-01-01
In the year 2025, wildland fire fighting practices have improved significantly over the method employed during the late1900's. Improved methods for predicting severe fire weather conditions, the establishment of the North American Fire Coordination Center, and the utilization of foam products for both wildfire and structural fire control have significantly changed...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
46 CFR 161.002-12 - Manual fire alarm systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...
An examination of fuel particle heating during fire spread
Jack D. Cohen; Mark A. Finney
2010-01-01
Recent high intensity wildfires and our demonstrated inability to control extreme fire behavior suggest a need for alternative approaches for preventing wildfire disasters. Current fire spread models are not sufficiently based on a basic understanding of fire spread processes to provide more effective management alternatives. An experimental and theoretical approach...
Wildland fire in ecosystems: fire and nonnative invasive plants
Kristin Zouhar; Jane Kapler Smith; Steve Sutherland; Matthew L. Brooks
2008-01-01
This state-of-knowledge review of information on relationships between wildland fire and nonnative invasive plants can assist fire managers and other land managers concerned with prevention, detection, and eradication or control of nonnative invasive plants. The 16 chapters in this volume synthesize ecological and botanical principles regarding relationships between...
a slope faces. Backfiring When attacking a wildland fire using the indirect attack method convective column. Black Line When putting in control lines, the process of burning out any pockets of small wildland fire. Burning Out When attack on the wildland fire is direct, or parallel with the
Code of Federal Regulations, 2012 CFR
2012-07-01
... that is not a prescribed fire that damages the National Forest System. (f) Building, attending... prevent its escape. (g) Negligently failing to maintain control of a prescribed fire on Non-National... 36 Parks, Forests, and Public Property 2 2012-07-01 2012-07-01 false Fire. 261.5 Section 261.5...
Code of Federal Regulations, 2014 CFR
2014-07-01
... that is not a prescribed fire that damages the National Forest System. (f) Building, attending... prevent its escape. (g) Negligently failing to maintain control of a prescribed fire on Non-National... 36 Parks, Forests, and Public Property 2 2014-07-01 2014-07-01 false Fire. 261.5 Section 261.5...
Code of Federal Regulations, 2011 CFR
2011-07-01
... that is not a prescribed fire that damages the National Forest System. (f) Building, attending... prevent its escape. (g) Negligently failing to maintain control of a prescribed fire on Non-National... 36 Parks, Forests, and Public Property 2 2011-07-01 2011-07-01 false Fire. 261.5 Section 261.5...
Code of Federal Regulations, 2013 CFR
2013-07-01
... that is not a prescribed fire that damages the National Forest System. (f) Building, attending... prevent its escape. (g) Negligently failing to maintain control of a prescribed fire on Non-National... 36 Parks, Forests, and Public Property 2 2013-07-01 2013-07-01 false Fire. 261.5 Section 261.5...
Code of Federal Regulations, 2010 CFR
2010-07-01
... that is not a prescribed fire that damages the National Forest System. (f) Building, attending... prevent its escape. (g) Negligently failing to maintain control of a prescribed fire on Non-National... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Fire. 261.5 Section 261.5...
43 CFR 8360.0-5 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
...; potable water; grills or fire rings; tables; or controlled access. (d) Public lands means any lands and... controlled fire occurring out of doors, used for cooking, branding, personal warmth, lighting, ceremonial or...
43 CFR 8360.0-5 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
...; potable water; grills or fire rings; tables; or controlled access. (d) Public lands means any lands and... controlled fire occurring out of doors, used for cooking, branding, personal warmth, lighting, ceremonial or...
43 CFR 8360.0-5 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
...; potable water; grills or fire rings; tables; or controlled access. (d) Public lands means any lands and... controlled fire occurring out of doors, used for cooking, branding, personal warmth, lighting, ceremonial or...
43 CFR 8360.0-5 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; potable water; grills or fire rings; tables; or controlled access. (d) Public lands means any lands and... controlled fire occurring out of doors, used for cooking, branding, personal warmth, lighting, ceremonial or...
A subsurface depocenter in the South Polar Layered Deposits of Mars
NASA Astrophysics Data System (ADS)
Whitten, J. L.; Campbell, B. A.; Morgan, G. A.
2017-08-01
The South Polar Layered Deposits (SPLD) are one of the largest water ice reservoirs on Mars, and their accumulation is driven by variations in the climate primarily controlled by orbital forcings. Patterns of subsurface layering in the SPLD provide important information about past atmospheric dust content, periods of substantial erosion, and variations in local or regional deposition. Here we analyze the SPLD using SHAllow RADar (SHARAD) sounder data to gain a unique perspective on the interior structure of the deposits and to determine what subsurface layers indicate about the preserved climate history. SHARAD data reveal a major deviation from the gently domical layering typical of the SPLD: a subsurface elongate dome. The dome most likely formed due to variations in the accumulation of ice and snow across the cap, with a higher rate occurring in this region over a prolonged period. This SPLD depositional center provides an important marker of south polar climate patterns.
Alternate energy source usage for in situ heat treatment processes
Stone, Jr., Francis Marion; Goodwin, Charles R [League City, TX; Richard, Jr., James
2011-03-22
Systems, methods, and heaters for treating a subsurface formation are described herein. At least one system for providing power to one or more subsurface heaters is described herein. The system may include an intermittent power source; a transformer coupled to the intermittent power source, and a tap controller coupled to the transformer. The transformer may be configured to transform power from the intermittent power source to power with appropriate operating parameters for the heaters. The tap controller may be configured to monitor and control the transformer so that a constant voltage is provided to the heaters from the transformer regardless of the load of the heaters and the power output provided by the intermittent power source.
NASA Astrophysics Data System (ADS)
Forkel, Matthias; Dorigo, Wouter; Lasslop, Gitta; Teubner, Irene; Chuvieco, Emilio; Thonicke, Kirsten
2017-12-01
Vegetation fires affect human infrastructures, ecosystems, global vegetation distribution, and atmospheric composition. However, the climatic, environmental, and socioeconomic factors that control global fire activity in vegetation are only poorly understood, and in various complexities and formulations are represented in global process-oriented vegetation-fire models. Data-driven model approaches such as machine learning algorithms have successfully been used to identify and better understand controlling factors for fire activity. However, such machine learning models cannot be easily adapted or even implemented within process-oriented global vegetation-fire models. To overcome this gap between machine learning-based approaches and process-oriented global fire models, we introduce a new flexible data-driven fire modelling approach here (Satellite Observations to predict FIre Activity, SOFIA approach version 1). SOFIA models can use several predictor variables and functional relationships to estimate burned area that can be easily adapted with more complex process-oriented vegetation-fire models. We created an ensemble of SOFIA models to test the importance of several predictor variables. SOFIA models result in the highest performance in predicting burned area if they account for a direct restriction of fire activity under wet conditions and if they include a land cover-dependent restriction or allowance of fire activity by vegetation density and biomass. The use of vegetation optical depth data from microwave satellite observations, a proxy for vegetation biomass and water content, reaches higher model performance than commonly used vegetation variables from optical sensors. We further analyse spatial patterns of the sensitivity between anthropogenic, climate, and vegetation predictor variables and burned area. We finally discuss how multiple observational datasets on climate, hydrological, vegetation, and socioeconomic variables together with data-driven modelling and model-data integration approaches can guide the future development of global process-oriented vegetation-fire models.
Method and apparatus for checking fire detectors
NASA Technical Reports Server (NTRS)
Clawson, G. T. (Inventor)
1974-01-01
A fire detector checking method and device are disclosed for nondestructively verifying the operation of installed fire detectors of the type which operate on the principle of detecting the rate of temperature rise of the ambient air to sound an alarm and/or which sound an alarm when the temperature of the ambient air reaches a preset level. The fire alarm checker uses the principle of effecting a controlled simulated alarm condition to ascertain wheather or not the detector will respond. The checker comprises a hand-held instrument employing a controlled heat source, e.g., an electric lamp having a variable input, for heating at a controlled rate an enclosed mass of air in a first compartment, which air mass is then disposed about the fire detector to be checked. A second compartment of the device houses an electronic circuit to sense and adjust the temperature level and heating rate of the heat source.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, Zhi; Zhang, Mingli; Ma, Wei
Subsurface moisture content is one of the critical factors that control the thermal dynamics of embankments. However, information on the subsurface moisture movement and distribution in embankments is still limited. To better understand the coupled water and heat transport within embankments, subsurface temperature and moisture of an asphalt pavement highway were extensively measured from 2009 to 2011. Collected data indicate that pure heat conduction is the overall main mechanism of heat transport in the embankment and heat convection plays a relatively unimportant role in heat transport. The results also indicate that subsurface moisture and temperature dynamics in the asphalt layermore » is strongly related to the rainfall events, while the subsurface moisture content below the road base course maintains relatively constant. Rainfall in summer leads to rapid cooling of the subsurface soil. Our results suggest that frequent and small rainfall events favour the thermal stability of the embankment due to the loss of latent heat of water evaporation. Moisture migration during freezing still occurred in the gravel fill and the water infiltrated into the active layer during thawing period. Freezing-induced water migration may result in the increase in water content of the embankment and the decrease in compactness of gravel fill.« less
Regolith-atmosphere exchange of water in Mars' recent past
NASA Astrophysics Data System (ADS)
Steele, Liam J.; Balme, Matthew R.; Lewis, Stephen R.
2017-03-01
We investigate the exchange of water vapour between the regolith and atmosphere of Mars, and how it varies with different orbital parameters, atmospheric dust contents and surface water ice reservoirs. This is achieved through the coupling of a global circulation model (GCM) and a regolith diffusion model. GCM simulations are performed for hundreds of Mars years, with additional one-dimensional simulations performed for 50 kyr. At obliquities ɛ =15∘ and 30°, the thermal inertia and albedo of the regolith have more control on the subsurface water distribution than changes to the eccentricity or solar longitude of perihelion. At ɛ =45∘ , atmospheric water vapour abundances become much larger, allowing stable subsurface ice to form in the tropics and mid-latitudes. The circulation of the atmosphere is important in producing the subsurface water distribution, with increased water content in various locations due to vapour transport by topographically-steered flows and stationary waves. As these circulation patterns are due to topographic features, it is likely the same regions will also experience locally large amounts of subsurface water at different epochs. The dustiness of the atmosphere plays an important role in the distribution of subsurface water, with a dusty atmosphere resulting in a wetter water cycle and increased stability of subsurface ice deposits.
Burnout control at the Albright coal-waste-bank fire. Rept. of investigations/1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaiken, R.F.; Bayles, L.G.
1991-01-01
Burnout Control is a process developed by the U.S. Bureau of Mines for accelerating the burning of wasted coal fires in situ, while at the same time controlling the heat and fumes produced. The Albright fire project is a first field trial of Burnout Control as applied to a coal waste bank. An exhaust ventilation system was designed and constructed and then operated over a 1-year period at the site of an existing abandoned mine land fire near the town of Albright, W.V. While predicted exhaust gas temperatures of 900 C and thermal power levels of 5 MW were achievedmore » at 20- to 30-in H2O vacuum levels, problems were encountered with engineering designs, equipment breakdown, and fuel-rich combustion that curtailed the time period of satisfactory operation. Effective afterburning of the exhaust gases (as they were drawn from the bank) corrected the problems associated with combustion stoichiometry and led to high thermal outputs. It is believed that with (1) improvements in engineering design and construction, (2) better control of the afterburning process, and (3) the use of conventional stack gas air-pollution controls, Burnout Control can be applied successfully to a coal waste bank fire.« less
The Pictorial Fire Stroop: a measure of processing bias for fire-related stimuli.
Gallagher-Duffy, Joanne; MacKay, Sherri; Duffy, Jim; Sullivan-Thomas, Meara; Peterson-Badali, Michele
2009-11-01
Fire interest is a risk factor for firesetting. This study tested whether a fire-specific emotional Stroop task can effectively measure an information-processing bias for fire-related stimuli. Clinic-referred and nonreferred adolescents (aged 13-16 years) completed a pictorial "Fire Stroop," as well as a self-report fire interest questionnaire and several control tasks. Results showed (a) comparatively greater fire-specific attentional bias among referred adolescent firesetters, (b) a negative relationship between Fire Stroop attentional bias and self-reported fire interest, and (c) positive correspondence between Fire Stroop attentional bias and self-reported firesetting frequency. These findings suggest that instruments that measure an automatic bias for fire-specific stimuli may usefully supplement self-report measures in the assessment and understanding of firesetting behavior.
Summaries of BFRL fire research in-house projects and grants, 1993
NASA Astrophysics Data System (ADS)
Jason, Nora H.
1993-09-01
The report describes the fire research projects performed in the Building and Fire Research Laboratory (BFRL) and under its extramural grants program during fiscal year 1993. The BFRL Fire Research Program has directed its efforts under three program thrusts. The in-house priority projects, grants, and externally-funded efforts thus form an integrated, focussed ensemble. The publication is organized along those lines: fire risk and hazard prediction - carbon monoxide prediction, turbulent combustion, soot, engineering analysis, fire hazard assessment, and large fires; fire safety of products and materials - materials combustion, furniture flammability, and wall and ceiling fires; and advanced technologies for fire sensing and control - fire detection and fire suppression. For the convenience of the reader, an alphabetical listing of all grants is contained in Part 2.0.
Growing season burns for control of hardwoods in longleaf pine stands
William D. Boyer
1990-01-01
Summer fires in existing longleaf pine stands carry undue risk of pine mortality. One summer fire caused as much mortality among pines in the l- through 4-inch d.b.h. classes as two successive summer fires among hardwoods of the same size. Mortality among mature pines was also excessive. Hardwood top-kill following a spring fire seemed affected more by fire intensity...
Brian R. Sturtevant; Brian R. Miranda; Jian Yang; Hong S. He; Eric J. Gustafson; Robert M. Scheller
2009-01-01
Public forests are surrounded by land over which agency managers have no control, and whose owners expect the public forest to be a "good neighbor." Fire risk abatement on multi-owner landscapes containing flammable but fire-dependent ecosystems epitomizes the complexities of managing public lands. We report a case study that applies a landscape disturbance...
Use of expert knowledge to develop fuel maps for wildland fire management [chapter 11
Robert E. Keane; Matt Reeves
2012-01-01
Fuel maps are becoming an essential tool in fire management because they describe, in a spatial context, the one factor that fire managers can control over many scales  surface and canopy fuel characteristics. Coarse-resolution fuel maps are useful in global, national, and regional fire danger assessments because they help fire managers effectively plan, allocate, and...
Christopher D. O' Connor; David E. Calkin; Matthew P. Thompson
2017-01-01
During active fire incidents, decisions regarding where and how to safely and effectively deploy resources to meet management objectives are often made under rapidly evolving conditions, with limited time to assess management strategies or for development of backup plans if initial efforts prove unsuccessful. Under all but the most extreme fire weather conditions,...
Rates of initial spread of free-burning fires on the National Forests of California
C.A. Abell
1940-01-01
As early as 1914 Coert DuBois and his staff recognized that knowledge of the rates which fires spread was essential to sound fire control planning, strategy, and tactics, and therefore designed the fire report form so that such data might be accumulated. Although the individual fire report form has changed appreciably since that time, the supply of data has grown...
Thermal weapon sights with integrated fire control computers: algorithms and experiences
NASA Astrophysics Data System (ADS)
Rothe, Hendrik; Graswald, Markus; Breiter, Rainer
2008-04-01
The HuntIR long range thermal weapon sight of AIM is deployed in various out of area missions since 2004 as a part of the German Future Infantryman system (IdZ). In 2007 AIM fielded RangIR as upgrade with integrated laser Range finder (LRF), digital magnetic compass (DMC) and fire control unit (FCU). RangIR fills the capability gaps of day/night fire control for grenade machine guns (GMG) and the enhanced system of the IdZ. Due to proven expertise and proprietary methods in fire control, fast access to military trials for optimisation loops and similar hardware platforms, AIM and the University of the Federal Armed Forces Hamburg (HSU) decided to team for the development of suitable fire control algorithms. The pronounced ballistic trajectory of the 40mm GMG requires most accurate FCU-solutions specifically for air burst ammunition (ABM) and is most sensitive to faint effects like levelling or firing up/downhill. This weapon was therefore selected to validate the quality of the FCU hard- and software under relevant military conditions. For exterior ballistics the modified point mass model according to STANAG 4355 is used. The differential equations of motions are solved numerically, the two point boundary value problem is solved iteratively. Computing time varies according to the precision needed and is typical in the range from 0.1 - 0.5 seconds. RangIR provided outstanding hit accuracy including ABM fuze timing in various trials of the German Army and allied partners in 2007 and is now ready for series production. This paper deals mainly with the fundamentals of the fire control algorithms and shows how to implement them in combination with any DSP-equipped thermal weapon sights (TWS) in a variety of light supporting weapon systems.
Tjelele, Julius; Ward, David; Dziba, Luthando
2015-01-01
The increasing rate of woody plant encroachment in grasslands or savannas remains a challenge to livestock farmers. The causes and control measures of woody plant encroachment are of common interest, especially where it negatively affects the objectives of an agricultural enterprise. The objectives of this study were to determine the effects of gut passage (goats, cattle), dung (nutrients), fire, grass competition and trampling on establishment of A. nilotica and D. cinerea seedlings. Germination trials were subjected to the following treatments: 1) seed passage through the gut of cattle and goats and unpassed/ untreated seeds (i.e. not ingested), 2) dung and control (no dung), 3) grass and control (mowed grass), 4) fire and control (no fire), 5) trampling and control (no trampling). The interaction of animal species, grass and fire had an effect on seedling recruitment (P < 0.0052). Seeds retrieved from goats and planted with no grass and with fire (6.81% ± 0.33) had a significant effect on seedling recruitment than seeds retrieved from goats and planted with grass and no fire (2.98% ± 0.33). Significantly more D. cinerea and A. nilotica seeds germinated following seed ingestion by goats (3.59% ± 0.16) than cattle (1.93% ± 0.09) and control or untreated seeds (1.69% ± 0.11). Less dense grass cover, which resulted in reduced grass competition with tree seedlings for light, space and water, and improved seed scarification due to gut passage were vital for emergence and recruitment of Acacia seedlings. These results will contribute considerably to the understanding of the recruitment phase of woody plant encroachment. PMID:25695765
NASA Astrophysics Data System (ADS)
Doerr, Stefan H.; Shakesby, Richard A.; Sheridan, Gary J.; Lane, Patrick Nj; Smith, Hugh G.; Bell, Tina; Blake, William H.
2010-05-01
The recent catastrophic wildfires near Melbourne, which peaked on Feb. 7 2009, burned ca 400,000 ha and caused the tragic loss of 173 people. They occurred during unprecedented extreme fire weather where dry northerly winds gusting up to 100 km/h coincided with the highest temperatures ever recorded in this region. These conditions, combined with the very high biomass of mature eucalypt forests, very low fuel moisture conditions and steep slopes, generated extreme burning conditions. A rapid response project was launched under the NERC Urgency Scheme aimed at determining the effects of this extreme event on soil properties. Three replicate sites each were sampled for extremely high burn severity, high burn severity and unburnt control terrain, within mature mixed-species eucalypt forests near Marysville in April 2009. Ash and surface soil (0-2.5 cm and 2.5-5 cm) were collected at 20 sample grid points at each site. Here we report on outcomes from Water Drop Penetration Time (WDPT) tests carried out on soil samples to determine the impact of this extreme event on the wettability of a naturally highly water repellent soil. Field assessment suggested that the impact of this extreme wildfire on the soil was less than might be supposed given the extreme burn severity (indicated by the complete elimination of the ground vegetation). This was confirmed by the laboratory results. No major difference in WDPT was detected between (i) burned and control samples, and (ii) between surface and subsurface WDPT patterns, indicating that soil temperatures in the top 0-2.5 cm did not exceed ~200° C. Seedling germination in burned soil was reduced by at least 2/3 compared to the control samples, however, this reduction is indicative an only modest heat input into the soil. The limited heat input into the soil stands in stark contrast to the extreme burn severity (based on vegetation destruction parameters). We speculate that limited soil heating resulted perhaps from the unusually fast-moving fire front and the resultant short fire residence time during this event. Thick ash layers were present at the time of sampling despite some significant earlier pre-sampling rainfall events. This suggests that the wettable ash (up to 15 cm thick) was able to store substantial amounts of water, which would otherwise have formed overland flow moving over the highly water repellent underlying mineral soil. Once this hydrological ‘sponge' is removed, the lack of ground cover is expected to lead to the underlying soil being susceptible to erosion until the ground cover becomes re-established. This ‘erosion window‘ is likely to be relatively brief over much of the burnt area as the vegetation is already showing a comparatively rapid regrowth response. This is supported by initial results from laboratory germination experiments, which showed seedling emergence from even the most severely burnt sites. The factors contributing to the fire impacts determined here are explored in conjunction with predictions for future burn severity under a changing climate. The soil samples collected represent a reference soil sample collection, which are available to the scientific community for further investigation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2011 CFR
2011-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2010 CFR
2010-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2013 CFR
2013-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
An application of LANDSAT digital technology to forest fire fuel type mapping
NASA Technical Reports Server (NTRS)
Kourtz, P. H.
1977-01-01
The role of digital classifications suitable as fuel maps was examined. A Taylor enhancement was produced for an 8 million hectare fire control region showing water, muskeg, coniferous, deciduous and mixed stands, clearcut logging, burned areas, regeneration areas, nonforested areas and large forest roads. Use of the map by fire control personnel demonstrated its usefulness for initial attack decision making.
2009-05-06
CAPE CANAVERAL, Fla. – New windows are installed in the Launch Control Center's Firing Room 1 at NASA's Kennedy Space Center in Florida. The firing room will support the future Ares rocket launches as part of NASA's Constellation Program. Future astronauts will ride to orbit on Ares I, launched from Kennedy's Launch Pad 39B. The Launch Control Center firing rooms face the launch pads. Photo credit: NASA/Jack Pfaller
2009-05-06
CAPE CANAVERAL, Fla. – New windows are installed in the Launch Control Center's Firing Room 1 at NASA's Kennedy Space Center in Florida. The firing room will support the future Ares rocket launches as part of NASA's Constellation Program. Future astronauts will ride to orbit on Ares I, launched from Kennedy's Launch Pad 39B. The Launch Control Center firing rooms face the launch pads. Photo credit: NASA/Jack Pfaller
WISDOM measurements in a cold artificial and controlled environment
NASA Astrophysics Data System (ADS)
Dechambre, M.; Saintenoy, A.; Ciarletti, V.; Biancheri-Astier, M.; Costard, F.; Hassen-Khodja, R.
2011-10-01
The WISDOM (500MHz - 3GHz) GPR is one of the instruments that have been selected as part of the Pasteur payload of ESA's 2018 ExoMars Rover mission. One of the main scientific objectives of the mission is to characterize the nature of the shallow sub-surface on Mars and WISDOM has been designed to explore the first ~ 3 meters of the subsurface with a vertical resolution of a few centimetres. Full polarimetric measurements in cold artificial and controlled conditions have been performed by the prototype to illustrate and quantify the instrument performance. Preliminary results are presented.
NASA Technical Reports Server (NTRS)
Altman, R. L.; Ling, A. C. (Editor); Mayer, L. A.; Myronik, D. J.
1979-01-01
The effectiveness of dry chemical in extinguishing and delaying reignition of fires resulting from hydrocarbon fuel leaking onto heated surfaces such as can occur in jet engine nacelles is studied. The commercial fire extinguishant dry chemical tried are sodium and potassium bicarbonate, carbonate, chloride, carbamate (Monnex), metal halogen, and metal hydroxycarbonate compounds. Synthetic and preparative procedures for new materials developed, a new concept of fire control by dry chemical agents, descriptions of experiment assemblages to test dry chemical fire extinguishant efficiencies in controlling fuel fires initiated by hot surfaces, comparative testing data for more than 25 chemical systems in a 'static' assemblage with no air flow across the heated surface, and similar comparative data for more than ten compounds in a dynamic system with air flows up to 350 ft/sec are presented.
2014-04-03
CAPE CANAVERAL, Fla. – The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. In view along the soffit are space shuttle launch plaques for 21 missions launched from Firing Room 4. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
Efficacy of a proactive health and safety risk management system in the fire service.
Poplin, Gerald S; Griffin, Stephanie; Pollack Porter, Keshia; Mallett, Joshua; Hu, Chengcheng; Day-Nash, Virginia; Burgess, Jefferey L
2018-04-16
This study evaluated the efficacy of a fire department proactive risk management program aimed at reducing firefighter injuries and their associated costs. Injury data were collected for the intervention fire department and a contemporary control department. Workers' compensation claim frequency and costs were analyzed for the intervention fire department only. Total, exercise, patient transport, and fireground operations injury rates were calculated for both fire departments. There was a post-intervention average annual reduction in injuries (13%), workers' compensation injury claims (30%) and claims costs (21%). Median monthly injury rates comparing the post-intervention to the pre-intervention period did not show statistically significant changes in either the intervention or control fire department. Reduced workers' compensation claims and costs were observed following the risk management intervention, but changes in injury rates were not statistically significant.
Morrongiello, Barbara A; Schwebel, David C; Bell, Melissa; Stewart, Julia; Davis, Aaron L
2012-07-01
Fire is a leading cause of unintentional injury and, although young children are at particularly increased risk, there are very few evidence-based resources available to teach them fire safety knowledge and behaviors. Using a pre-post randomized design, the current study evaluated the effectiveness of a computer game (The Great Escape) for teaching fire safety information to young children (3.5-6 years). Using behavioral enactment procedures, children's knowledge and behaviors related to fire safety were compared to a control group of children before and after receiving the intervention. The results indicated significant improvements in knowledge and fire safety behaviors in the intervention group but not the control. Using computer games can be an effective way to promote young children's understanding of safety and how to react in different hazardous situations.
NASA Technical Reports Server (NTRS)
Cukor, P. M.; Chapman, R. A.
1978-01-01
The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.
Influence of bedrock topography on the runoff generation under use of ERT data
NASA Astrophysics Data System (ADS)
Kiese, Nina; Loritz, Ralf; Allroggen, Niklas; Zehe, Erwin
2017-04-01
Subsurface topography has been identified to play a major role for the runoff generation in different hydrological landscapes. Sinks and ridges in the bedrock can control how water is stored and transported to the stream. Detecting the subsurface structure is difficult and laborious and frequently done by auger measurements. Recently, the geophysical imaging of the subsurface by Electrical Resistivity Tomography (ERT) gained much interest in the field of hydrology, as it is a non-invasive method to collect information on the subsurface characteristics and particularly bedrock topography. As it is impossible to characterize the subsurface of an entire hydrological landscape using ERT, it is of key interest to identify the bedrock characteristics which dominate runoff generation to adapt and optimize the sampling design to the question of interest. For this study, we used 2D ERT images and auger measurements, collected on different sites in the Attert basin in Luxembourg, to characterize bedrock topography using geostatistics and shed light on those aspects which dominate runoff generation. Based on ERT images, we generated stochastic bedrock topographies and implemented them in a physically-based 2D hillslope model. With this approach, we were able to test the influence of different subsurface structures on the runoff generation. Our results highlight that ERT images can be useful for hydrological modelling. Especially the connection from the hillslope to the stream could be identified as important feature in the subsurface for the runoff generation whereas the microtopography of the bedrock seemed to be less relevant.
NASA Astrophysics Data System (ADS)
Hinojosa, M. B.; Parra, A.; Laudicina, V. A.; Moreno, J. M.
2014-10-01
Fire is a major ecosystem driver, causing significant changes in soil nutrients and microbial community structure and functionality. Post-fire soil dynamics can vary depending on rainfall patterns, although variations in response to drought are poorly known. This is particularly important in areas with poor soils and limited rainfall, like arid and semiarid ones. Furthermore, climate change projections in many such areas anticipate reduced precipitation and longer drought, together with an increase in fire severity. The effects of experimental drought and fire were studied on soils in a Mediterranean Cistus-Erica shrubland in Central Spain. A replicated (n = 4) field experiment was carried out in which four levels of rainfall pattern were implemented by means of a rain-out shelters and irrigation system. The treatments were: environmental control (natural rainfall), historical control (long-term average rainfall, 2 months drought), moderate drought (25% reduction of historical control, 5 months drought) and severe drought (45% reduction, 7 months drought). After one growing season, the plots were burned with high fire intensity, except a set of unburned plots that served as control. Soils were collected seasonally during one year and variables related to soil nutrient availability and microbial community structure and functionality were studied. Burned soils increased nutrient availability (P, N, K) with respect to unburned ones, but drought reduced such an increase in P, while it further increased N and K. Such changes in available soil nutrients were short-lived. Drought caused a further decrease of enzyme activities, carbon mineralization rate and microbial biomass. Fire decreased the relative abundance of fungi and actinomycetes. However, fire and drought caused a further reduction in fungi, with bacteria becoming relatively more abundant. Arguably, increasing drought and fires due to climate change will likely shift soil recovery after fire.
NASA Astrophysics Data System (ADS)
Yoon, J. S.; Culligan, P. J.; Germaine, J. T.
2003-12-01
Subsurface colloid behavior has recently drawn attention because colloids are suspected of enhancing contaminant transport in groundwater systems. To better understand the processes by which colloids move through the subsurface, and in particular the vadose zone, a new technique that enables real-time visualization of colloid particles as they move through a porous medium has been developed. This visualization technique involves the use of laser induced fluorescent particles and digital image processing to directly observe particles moving through a porous medium consisting of soda-lime glass beads and water in a transparent experimental box of 10.0cm\\x9D27.9cm\\x9D2.38cm. Colloid particles are simulated using commercially available micron sized particles that fluoresce under argon-ion laser light. The fluorescent light given off from the particles is captured through a camera filter, which lets through only the emitted wavelength of the colloid particles. The intensity of the emitted light is proportional to the colloid particle concentration. The images of colloid movement are captured by a MagnaFire digital camera; a cooled CCD digital camera produced by Optronics. This camera enables real-time capture of images to a computer, thereby allowing the images to be processed immediately. The images taken by the camera are analyzed by the ImagePro software from Media Cybernetics, which contains a range of counting, sizing, measuring, and image enhancement tools for image processing. Laboratory experiments using the new technique have demonstrated the existence of both irreversible and reversible sites for colloid entrapment during uniform saturated flow in a homogeneous porous medium. These tests have also shown a dependence of colloid entrapment on velocity. Models for colloid transport currently available in the literature have proven to be inadequate predictors for the experimental observations, despite the simplicity of the system studied. To further extend the work, the visualization technique has been developed for use on the geo-centrifuge. The advantage that the geo-centrifuge has for investigating subsurface colloid behavior, is the ability to simulate unsaturated transport mechanisms under well simulated field moisture profiles and in shortened periods of time. A series of tests to investigate colloid transport during uniform saturated flow is being used to examine basic scaling laws for colloid transport under enhanced gravity. The paper will describe the new visualization technique, its use in geo-centrifuge testing and observations on scaling relationships for colloid transport during geo-centrifuge experiments. Although the visualization technique has been developed for investigating subsurface colloid behavior, it does have application in other areas of investigation, including the investigation of microbial behavior in the subsurface.
Fire Control and Human Evolution.
ERIC Educational Resources Information Center
Russell, Claire
1978-01-01
Briefly outlines some aspects of the discovery of fire control by primitive people, such as the preadaptation for speech, the evolution of the human brain, and natural selection for human nakedness or loss of hair. (CS)
14 CFR 23.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... controls, engine mounts, and other flight structure. Flight controls, engine mounts, and other flight... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection of flight controls, engine mounts, and other flight structure. 23.865 Section 23.865 Aeronautics and Space FEDERAL AVIATION...
14 CFR 23.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... controls, engine mounts, and other flight structure. Flight controls, engine mounts, and other flight... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection of flight controls, engine mounts, and other flight structure. 23.865 Section 23.865 Aeronautics and Space FEDERAL AVIATION...
14 CFR 23.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... controls, engine mounts, and other flight structure. Flight controls, engine mounts, and other flight... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection of flight controls, engine mounts, and other flight structure. 23.865 Section 23.865 Aeronautics and Space FEDERAL AVIATION...
14 CFR 23.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... controls, engine mounts, and other flight structure. Flight controls, engine mounts, and other flight... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of flight controls, engine mounts, and other flight structure. 23.865 Section 23.865 Aeronautics and Space FEDERAL AVIATION...
14 CFR 23.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... controls, engine mounts, and other flight structure. Flight controls, engine mounts, and other flight... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine mounts, and other flight structure. 23.865 Section 23.865 Aeronautics and Space FEDERAL AVIATION...
NASA Astrophysics Data System (ADS)
Potthast, Karin; Meyer, Stefanie; Crecelius, Anna; Schubert, Ulrich; Michalzik, Beate
2016-04-01
It is supposed that the changing climate will promote extreme weather events that in turn will increase drought periods and the abundance of fire events in temperate climate regions such as Central Europe. The impact of fires on the nutrient budgets of ecosystems is highly diverse and seems to depend on the ecosystem type. For example, little is known about fire effects on water-bound organic matter (OM) and nutrient fluxes in temperate managed forest ecosystems. Fires can strongly alter the distribution (forest floor vs. mineral soil), binding forms (organic vs. inorganic) and availability (solubility by water) of OM and associated nutrients. To elucidate the effects and seasonality of low intensity fires on the mobilization of dissolved organic carbon and nutrients, an experimental ground fire was conducted in November 2014 in the Hainich region, Central Germany. In addition, differences in response patterns between two land-use types (pasture and beech forest) were investigated. Lysimeters (n=5 controls/ 5 fire-manipulated) with topsoil monoliths (0-4 cm), rainfall/throughfall samplers, littertraps as well as temperature and moisture sensors were installed on three sites of each land-use type. During the one year of monitoring (Sep14-Dec15) soil solution, rainfall, and throughfall samples were taken biweekly and analyzed for pH, dissolved and particulate organic carbon (DOC, POC) and nitrogen (DN, PN) as well as for nutrients (e.g. K, Ca, Mg, P, S). Compared to the control sites, the ground fire immediately induced a short-run release peak of DOC in both land-use types. Within two weeks these differences were muted in the post-fire period. The effect of fire was land-use specific with annual DOC fluxes of 82 and 45 kg/(ha*a) for forest and pasture sites, respectively. In contrast, nitrogen fluxes responded differently to the fire event. In the forest, a significant increase in DN concentrations was notable five months after the fire, at the beginning of the vegetation period and lasted until November with DN concentrations in June being 4 times higher compared to the control (82 vs. 18 mg DN/L) and being negatively correlated with pH-values (r=-0.51 p<0.001). Annual DN fluxes from fire manipulated forest plots were two times higher compared to control ones (62 vs. 29 kg DN/(ha*a)) whereas only low impact was found at the pasture with 45 and 38 kg DN/(ha*a) for fire-manipulated plots and control, respectively. In general, the results exhibit highly differing response patterns of elements to fire between the two land-use types and with season. Starting in spring higher DN fluxes following fire event at the forest site could be associated with accelerated activity of soil microbes mineralizing released organic substances from burned forest floor and/or from dead roots. This mineralization process resulted in a significant increase in acidity of the soil solution that may affect important ecosystem functions like nutrient cycling and primary production. Hence, high resolution monitoring following a low intensive fire indicated nutrient losses from the forest ecosystem that could be a hazard for managed forests on nutrient poor soils if fire frequency increases with climate change.
AEGIS: a wildfire prevention and management information system
Kostas Kalabokidis; Alan Ager; Mark Finney; Nikos Athanasis; Palaiologos Palaiologou; Christos Vasilakos
2016-01-01
We describe a Web-GIS wildfire prevention and management platform (AEGIS) developed as an integrated and easy-to-use decision support tool to manage wildland fire hazards in Greece (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing online access to...
USDA-ARS?s Scientific Manuscript database
Prescribed fire can be used to return wild lands to their natural fire cycle, control invasive weeds, and reduce fuel loads, but there are gaps in the understanding of post-disturbance responses of vegetation and hydrology. The impact of a prescribed fire and subsequent aspen cutting on evapotransp...
A review of the relationships between drought and forest fire in the United States
Jeremy S. Littell; David L. Peterson; Karin L. Riley; Yongqiang Liu; Charlie H. Luce
2016-01-01
The historical and presettlement relationships between drought and wildfire are well documented in North America, with forest fire occurrence and area clearly increasing in response to drought. There is also evidence that drought interacts with other controls (forest productivity, topography, fire weather, management activities) to affect fire intensity,...
Ten-year responses of oak regeneration to prescribed fire
Erik Berg; Barry Clinton; Jim Vose; Wayne Swank
2011-01-01
Prescribed fire has proven effective in controlling vegetative competition of oak regeneration across many sites in the southeastern US most fire investigations have been performed in the Piedmont and Coastal Plain. Land managers lake definitive knowledge on how to use prescribed fire to improve long-term oak regeneration success in the southern Appalachians. Several...
Production and efficiency of large wildland fire suppression effort: A stochastic frontier analysis
Hari Katuwal; Dave Calkin; Michael S. Hand
2016-01-01
This study examines the production and efficiency of wildland fire suppression effort. We estimate the effectiveness of suppression resource inputs to produce controlled fire lines that contain large wildland fires using stochastic frontier analysis. Determinants of inefficiency are identified and the effects of these determinants on the daily production of...
George R. Fahnestock
1960-01-01
Some of the most disastrous forest fires in North American history burned in slash left from logging and land clearing. In the era before organized fire control, the names Miramichi, Peshtigo, Hinckley, and Cloquet stand for millions of acres blackened and thousands of lives snuffed out. More recently the Half Moon Fire in Montana, the Tillamook Fire in Oregon, the...
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... systems will be considered to consist of normal and emergency power supplies, a fire detecting control... subpart, manual fire alarm systems will be considered to consist of normal and emergency power supplies, a...
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... systems will be considered to consist of normal and emergency power supplies, a fire detecting control... subpart, manual fire alarm systems will be considered to consist of normal and emergency power supplies, a...
An approach to the real time risk evaluation system of boreal forest fire
NASA Astrophysics Data System (ADS)
Nakau, K.; Fukuda, M.; Kimura, K.; Hayasaka, H.; Tani, H.; Kushida, K.
2005-12-01
Huge boreal forest fire may cause massive impacts not only on global warming gas emission but also local communities. Thus, it is important to control forest fire. We collected data about boreal forest fire as satellite imagery and fire observation simultaneously in Alaska and east Siberia in summer fire seasons for these three years. Fire observation data was collected from aircraft flying between Japan and Europe. Fire detection results were compared with observed data to evaluate the accuracy and earliness of automatic detection. NOAA and MODIS satellite images covering Alaska and East Siberia are collected. We are also developing fire expansion simulation model to forecast the possible fire expansion area. On the basis of fire expansion forecast, risk analysis of possible fire expansion for decision aid of fire-fighting activities will be analyzed. To identify the risk of boreal forest fire and public concern about forest fire, we collected local news paper in Fairbanks, AK and discuss the statistics of articles related to forest fire on the newspaper.
2016-01-01
Fire plays an increasingly significant role in tropical forest and savanna ecosystems, contributing to greenhouse gas emissions and impacting on biodiversity. Emerging research shows the potential role of Indigenous land-use practices for controlling deforestation and reducing CO2 emissions. Analysis of satellite imagery suggests that Indigenous lands have the lowest incidence of wildfires, significantly contributing to maintaining carbon stocks and enhancing biodiversity. Yet acknowledgement of Indigenous peoples' role in fire management and control is limited, and in many cases dismissed, especially in policy-making circles. In this paper, we review existing data on Indigenous fire management and impact, focusing on examples from tropical forest and savanna ecosystems in Venezuela, Brazil and Guyana. We highlight how the complexities of community owned solutions for fire management are being lost as well as undermined by continued efforts on fire suppression and firefighting, and emerging approaches to incorporate Indigenous fire management into market- and incentive-based mechanisms for climate change mitigation. Our aim is to build a case for supporting Indigenous fire practices within all scales of decision-making by strengthening Indigenous knowledge systems to ensure more effective and sustainable fire management. This article is part of the themed issue ‘The interaction of fire and mankind’. PMID:27216507
Mistry, Jayalaxshmi; Bilbao, Bibiana A; Berardi, Andrea
2016-06-05
Fire plays an increasingly significant role in tropical forest and savanna ecosystems, contributing to greenhouse gas emissions and impacting on biodiversity. Emerging research shows the potential role of Indigenous land-use practices for controlling deforestation and reducing CO2 emissions. Analysis of satellite imagery suggests that Indigenous lands have the lowest incidence of wildfires, significantly contributing to maintaining carbon stocks and enhancing biodiversity. Yet acknowledgement of Indigenous peoples' role in fire management and control is limited, and in many cases dismissed, especially in policy-making circles. In this paper, we review existing data on Indigenous fire management and impact, focusing on examples from tropical forest and savanna ecosystems in Venezuela, Brazil and Guyana. We highlight how the complexities of community owned solutions for fire management are being lost as well as undermined by continued efforts on fire suppression and firefighting, and emerging approaches to incorporate Indigenous fire management into market- and incentive-based mechanisms for climate change mitigation. Our aim is to build a case for supporting Indigenous fire practices within all scales of decision-making by strengthening Indigenous knowledge systems to ensure more effective and sustainable fire management.This article is part of the themed issue 'The interaction of fire and mankind'. © 2016 The Author(s).
Barbeau, E; Kelder, G; Ahmed, S; Mantuefel, V; Balbach, E
2005-01-01
Background: Cigarettes are the leading cause of fatal fires in the USA and are associated with one in four fire deaths. Although the technology needed to make fire-safe cigarettes has been available for many years, progress has been slow on legislative and regulatory fronts to require the tobacco industry to manufacture fire-safe cigarettes. Method and results: We conducted a case study, drawing on data from tobacco industry documents, archives, and key informant interviews to investigate tobacco industry strategies for thwarting fire-safe cigarette legislation in the US Congress. We apply a theoretical framework that posits that policymaking is the product of three sets of forces: interests, institutions, and ideas, to examine tobacco industry behaviour, with a special focus on their and others' attempts to court fire service organisations, including firefighters' unions as allies. We discuss the implications of our findings for future policy efforts related to fire-safe cigarettes and other tobacco control issues. Conclusions: Tobacco control advocates ought to: continue efforts to align key interest groups, including the firefighters unions; contest tobacco industry "diversionary" science tactics; and pursue a state based legislative strategy for fire-safe cigarettes, building towards national legislation. PMID:16183985
NASA Astrophysics Data System (ADS)
Hope, Allen; Albers, Noah; Bart, Ryan
2010-05-01
Wildland fires in Mediterranean-Type Ecosystems (MTEs) are episodic events that dramatically alter land-cover conditions. Monitoring post-fire vegetation recovery is important for land management applications such as the scheduling of prescribed burns, post-fire resource management and soil erosion control. Full recovery of MTE shrublands may take many years and have a prolonged effect on water, energy and carbon fluxes in these ecosystems. Comparative studies of fynbos ecosystems in the Cape Floristic Region of South Africa (Western Cape Region) and chaparral ecosystems of California have demonstrated that there is a considerable degree of convergence in some aspects of post-fire vegetation regeneration and marked differences in other aspects. Since these MTEs have contrasting rainfall and soil nutrient conditions, an obvious question arises as to the similarity or dissimilarity in remotely sensed post-fire recovery pathways of vegetation stands in these two regions and the extent to which fire severity and drought impact the rate of vegetation recovery. Post-fire recovery pathways of chaparral and fynbos vegetation stands were characterized using the normalized difference vegetation index (NDVI) based on TM/ETM+ and MODIS (250 m) data. Procedures based on stands of unburned vegetation (control) were implemented to normalize the NDVI for variations associated with inter-annual differences in rainfall. Only vegetation stands that had not burned for 20 years were examined in this study to eliminate potential effects of variable fire histories on the recovery pathways. Post-fire recovery patterns of vegetation in both regions and across different vegetation types were found to be very similar. Post-fire stand age was the primary control over vegetation recovery and the NDVI returned to pre-fire values within seven to 10 years of the fires. Droughts were shown to cause slight interruptions in recovery rates while fire severity had no discernable effect. Intra-stand variability in the NDVI (pixel-scale) also returned to pre-fire values within the same time frame but increased with water stress associated with droughts. While these studies indicated that the NDVI of fynbos and chaparral stands recovered to pre-fire values within 10 years, it is recognized that other ecosystem characteristics may take considerably longer to recover. Despite the larger pixel size, MODIS data were found to be more suitable for monitoring vegetation post-fire recovery than TM/ETM+ data, requiring considerably less pre-processing and providing substantially more information regarding phenological characteristics of recovery pathways. Future studies will include consideration of fire history in the post-fire recovery characteristics of vegetation in these two MTEs.
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Controls and valves. 108.443 Section 108.443 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and...
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Controls and valves. 108.443 Section 108.443 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and...
Paleokarst processes in the Eocene limestones of the Pyramids Plateau, Giza, Egypt
NASA Astrophysics Data System (ADS)
El Aref, M. M.; Refai, E.
The Eocene limestones of the Pyramids plateau are characterized by landforms of stepped terraced escarpment and karst ridges with isolated hills. The carbonate country rocks are also dominated by minor surface, surface to subsurface and subsurface solution features associated with karst products. The systematic field observations eludicate the denudation trend of the minor solution features and suggest the origin of the regional landscapes. The lithologic and structural characters of the limestone country rocks comprise the main factors controlling the surface and subsurface karst evolution. The development of the karst features and the associated sediments in the study area provides information on the paleohydrolic, chemical and climatic environments involved in the origin of the karstification.
2014-04-03
CAPE CANAVERAL, Fla. – The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
2014-04-03
CAPE CANAVERAL, Fla. – Three rows of upper level management consoles are all that remain in Firing Room 4 in the Launch Control Center at NASA’s Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept that will support NASA and commercial launch needs. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
2014-04-03
CAPE CANAVERAL, Fla. – Three rows of upper level management consoles are all that remain in Firing Room 4 in the Launch Control Center at NASA’s Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept that will support NASA and commercial launch needs. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.
2016-10-24
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 57.6 mg/L, while the sub-surface sample was 106 mg/L. The Tank 43H samples ranged from 50.0 to 51.9 mg/L total uranium. The U-235 percentage was consistent for all four samples at 0.62%. The total uranium and percent U-235 results appear consistent with recent Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and somewhat higher concentrations than previous samples. The Pu-238 concentrationmore » is more than forty times higher in the Tank 38H sub-surface sample than the surface sample. The surface and sub-surface Tank 43H samples contain similar plutonium concentrations and are within the range of values measured on previous samples. The four samples analyzed show silicon concentrations somewhat higher than the previous sample with values ranging from 104 to 213 mg/L.« less
Video File - NASA Conducts 2nd RS-25 Engine Hot Fire of 2018 - 2018-02-01
2018-02-01
NASA Conducts 2nd RS-25 Engine Hot Fire of 2018. A 365-second hot fire test on Feb. 1, 2018, at NASA’s Stennis Space Center in Mississippi marks the completion of “green run” testing, or flight certification, for all new RS-25 engine flight controllers slated for Exploration Mission-2, the first Space Launch System mission with astronauts on board. In addition to the flight controller, the Feb. 1 hot fire also marked the third test of a 3D printed pogo accumulator assembly for the RS-25 engine.
LOCAL IMPACTS OF MERCURY EMISSIONS FROM COAL FIRED POWER PLANTS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SULLIVAN, T.M.; BOWERMAN, B.; ADAMS, J.
2004-03-30
A thorough quantitative understanding of the processes of mercury emissions, deposition, and translocation through the food chain is currently not available. Complex atmospheric chemistry and dispersion models are required to predict concentration and deposition contributions, and aquatic process models are required to predict effects on fish. There are uncertainties in all of these predictions. Therefore, the most reliable method of understanding impacts of coal-fired power plants on Hg deposition is from empirical data. A review of the literature on mercury deposition around sources including coal-fired power plants found studies covering local mercury concentrations in soil, vegetation, and animals (fish andmore » cows (Lopez et al. 2003)). There is strong evidence of enhanced local deposition within 3 km of the chlor-alkali plants, with elevated soil concentrations and estimated deposition rates of 10 times background. For coal-fired power plants, the data show that atmospheric deposition of Hg may be slightly enhanced. On the scale of a few km, modeling suggests that wet deposition may be increased by a factor of two or three over background. The measured data suggest lower increases of 15% or less. The effects of coal-fired plants seem to be less than 10% of total deposition on a national scale, based on emissions and global modeling. The following summarizes our findings from published reports on the impacts of local deposition. In terms of excesses over background the following increments have been observed within a few km of the plant: (1) local soil concentration Hg increments of 30%-60%, (2) sediment increments of 18-30%, (3) wet deposition increments of 11-12%, and (4) fish Hg increments of about 5-6%, based on an empirical finding that fish concentrations are proportional to the square root of deposition. Important uncertainties include possible reductions of RGM to Hg(0) in power plant plumes and the role of water chemistry in the relationship between Hg deposition and fish content. Soil and vegetation sampling programs were performed around two mid-size coal fired power plants. The objectives were to determine if local mercury hot spots exist, to determine if they could be attributed to deposition of coal-fired power plant emissions, and to determine if they correlated with model predictions. These programs found the following: (1) At both sites, there was no correlation between modeled mercury deposition and either soil concentrations or vegetation concentrations. At the Kincaid plant, there was excess soil Hg along heavily traveled roads. The spatial pattern of soil mercury concentrations did not match the pattern of vegetation Hg concentrations at either plant. (2) At both sites, the subsurface (5-10 cm) samples the Hg concentration correlated strongly with the surface samples (0-5 cm). Average subsurface sample concentrations were slightly less than the surface samples, however, the difference was not statistically significant. (3) An unequivocal definition of background Hg was not possible at either site. Using various assumed background soil mercury concentrations, the percentage of mercury deposited within 10 km of the plant ranged between 1.4 and 8.5% of the RGM emissions. Based on computer modeling, Hg deposition was primarily RGM with much lower deposition from elemental mercury. Estimates of the percentage of total Hg deposition ranged between 0.3 and 1.7%. These small percentages of deposition are consistent with the empirical findings of only minor perturbations in environmental levels, as opposed to ''hot spots'', near the plants. The major objective of this study was to determine if there was evidence for ''hot spots'' of mercury deposition around coal-fired power plants. Although the term has been used extensively, it has never been defined. From a public health perspective, such a ''hot spot'' must be large enough to insure that it did not occur by chance, and it must affect water bodies large enough to support a population of subsistence fishers. The results of this study support the hypothesis that neither of these conditions have been met.« less
2009-05-06
CAPE CANAVERAL, Fla. – A technician works at installing a new window in the Launch Control Center's Firing Room 1 at NASA's Kennedy Space Center in Florida. The firing room will support the future Ares rocket launches as part of NASA's Constellation Program. Future astronauts will ride to orbit on Ares I, launched from Kennedy's Launch Pad 39B. The Launch Control Center firing rooms face the launch pads. Photo credit: NASA/Jack Pfaller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalverny, L.E.; Chaiken, R.F.; Soroka, K.E.
1984-01-01
This report is the third in a five-part series that describes the Calamity Hollow Mine Fire Project. The first report, part 1, describes the design and construction of the field installation. Part 2 will present the results of a continuous 4-month burnout operation. (Because part 2 involves the analysis of a substantial body of data, it will not be published until after publication of parts 3, 4, and 5.) This part (part 3) describes the instrumentation used to control and monitor the progress of the burnout operation. Parts 4 and 5 both deal with the closeout phase of the fieldmore » demonstration. Part 4 describes the procedure used to quench the fire, and part 5 will describe the final excavation and backfilling of the heated zones. The reports in this series document the Calamity Hollow controlled burnout demonstration which showed that (1) controlled in situ combustion is a feasible method for controlling underground fires in abandoned mines, (2) the resultant thermal exhaust output is sufficient for energy utilization, and (3) water injection with fume exhaustion (WIFE) is a potentially effective method for cooling large underground fire zones. Further trials of both Burnout Control and the WIFE quenching procedure are planned.« less
Fail-safe fire detection system
NASA Technical Reports Server (NTRS)
Bloam, E. T.
1974-01-01
Fire detection control system continually monitors its own integrity, automatically signals any malfunction, and separately signals fire in any zone being monitored. Should be of interest in fields of chemical and petroleum processing, power generation, equipment testing, and building protection.
Pauses in cholinergic interneuron firing exert an inhibitory control on striatal output in vivo
Zucca, Stefano; Zucca, Aya; Nakano, Takashi; Aoki, Sho
2018-01-01
The cholinergic interneurons (CINs) of the striatum are crucial for normal motor and behavioral functions of the basal ganglia. Striatal CINs exhibit tonic firing punctuated by distinct pauses. Pauses occur in response to motivationally significant events, but their function is unknown. Here we investigated the effects of pauses in CIN firing on spiny projection neurons (SPNs) – the output neurons of the striatum – using in vivo whole cell and juxtacellular recordings in mice. We found that optogenetically-induced pauses in CIN firing inhibited subthreshold membrane potential activity and decreased firing of SPNs. During pauses, SPN membrane potential fluctuations became more hyperpolarized and UP state durations became shorter. In addition, short-term plasticity of corticostriatal inputs was decreased during pauses. Our results indicate that, in vivo, the net effect of the pause in CIN firing on SPNs activity is inhibition and provide a novel mechanism for cholinergic control of striatal output. PMID:29578407
A WebGIS-based command control system for forest fire fighting
NASA Astrophysics Data System (ADS)
Yang, Jianyu; Ming, Dongping; Zhang, Xiaodong; Huang, Haitao
2006-10-01
Forest is a finite resource and fire prevention is crucial work. However, once a forest fire or accident occurs, timely and effective fire-fighting is the only necessary measure. The aim of this research is to build a computerized command control system based on WEBGIS to direct fire-fighting. Firstly, this paper introduces the total technique flow and functional modules of the system. Secondly, this paper analyses the key techniques for building the system, and they are data obtaining, data organizing & management, architecture of WebGIS and sharing & interoperation technique. In the end, this paper demonstrates the on line martial symbol editing function to show the running result of system. The practical application of this system showed that it played very important role in the forest fire fighting work. In addition, this paper proposes some strategic recommendations for the further development of the system.
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and valves. (a) At least one control for operating a CO2 system must be outside the space or spaces that the...
Haack, Sheridan Kidd; Duris, Joseph W.
2008-01-01
A field trial was done in the Upper Tiffin River Watershed, in southeastern Michigan, to determine the influence of liquid dairy manure effluent (LDME) management practices on the quality of agricultural subsurface-drain water. Samples from subsurface drains were analyzed for nutrients, fecal-coliform and Escherichia coli (E. coli) bacteria, antibiotics, chemicals typically detected in wastewater, and the occurrence of genes indicating the presence of shiga-toxin-producing E. coli, or of bovine-specific Bacteroidetes bacteria. Samples were collected from November 2, 2006, to March 20, 2007, from eight subsurface drains under field plots that received no LDME and no tillage (controls) or received 4,000 or 8,000 gallons per acre (gal/acre) of LDME and either no tillage or two different types of tillage. The two types of tillage tested were (1) ground-driven, rotary, subsurface cultivation and (2) rolling-tine aeration. Samples were collected before LDME application and at 4 hours, and 1, 2, 6, 7, and 14 days post-application. Nutrient concentrations were high in subsurface-drain water throughout the field-trial period and could not be attributed to the field-trial LDME application. Of the 59 drain-water samples, including those collected before LDME application and control samples for each date, 56 had concentrations greater than the U.S. Environmental Protection Agency (USEPA), Ecoregion VI recommended surface-water criterion for total phosphorus, and all samples had concentrations greater than the recommended total nitrogen criterion. Nitrate + nitrite nitrogen concentration exceeded 20 milligrams per liter for every sample and contributed most to the total nitrogen concentrations. Substantial increases in drain-water concentrations of organic and ammonia nitrogen and total phosphorus were found for all treatments, including controls, at 14 days post-application after 0.84 inch of rainfall over 2 days. E. coli concentrations exceeded the USEPA recreational-water-quality single-sample criterion of 235 colony forming units per 100 milliliters in only 3 of 56 samples. Of these three samples, two were collected within 1 day post-LDME application from the treatment receiving 8,000 gal/acre LDME with no tillage (NT8000). The third sample was from the rolling-tine aerator treatment with 4,000 gal/acre LDME application rate after the first significant rainfall. Two wastewater chemicals and two bacterial genes (eaeA and stx1) detected in the LDME, but absent in field blank or pre-application samples, were detected in the 4-hour or 1-day postapplication NT8000 samples. No LDME-associated chemicals were detected in later samples from the NT8000 treatment, and none were detected in samples from other treatments after the first significant rainfall. Results of this field trial were somewhat equivocal with respect to the influence of LDME concentration and tillage practices on subsurface-drain water quality, both immediately after LDME application and in the longer term, after significant rainfall. Interpretation of study findings is limited by the fact that treatments were not replicated, and flow rate or discharge from the subsurface drains was not measured. Nevertheless, study results provide useful information about nutrient and bacteria concentrations in subsurface drains during the non-growing season. In addition, study results demonstrate some potential for the use of chemical and microbiological indicators of LDME transport to subsurface drains.
NASA Astrophysics Data System (ADS)
Kloster, S.; Mahowald, N. M.; Randerson, J. T.; Lawrence, P. J.
2012-01-01
Landscape fires during the 21st century are expected to change in response to multiple agents of global change. Important controlling factors include climate controls on the length and intensity of the fire season, fuel availability, and fire management, which are already anthropogenically perturbed today and are predicted to change further in the future. An improved understanding of future fires will contribute to an improved ability to project future anthropogenic climate change, as changes in fire activity will in turn impact climate. In the present study we used a coupled-carbon-fire model to investigate how changes in climate, demography, and land use may alter fire emissions. We used climate projections following the SRES A1B scenario from two different climate models (ECHAM5/MPI-OM and CCSM) and changes in population. Land use and harvest rates were prescribed according to the RCP 45 scenario. In response to the combined effect of all these drivers, our model estimated, depending on our choice of climate projection, an increase in future (2075-2099) fire carbon emissions by 17 and 62% compared to present day (1985-2009). The largest increase in fire emissions was predicted for Southern Hemisphere South America for both climate projections. For Northern Hemisphere Africa, a region that contributed significantly to the global total fire carbon emissions, the response varied between a decrease and an increase depending on the climate projection. We disentangled the contribution of the single forcing factors to the overall response by conducting an additional set of simulations in which each factor was individually held constant at pre-industrial levels. The two different projections of future climate change evaluated in this study led to increases in global fire carbon emissions by 22% (CCSM) and 66% (ECHAM5/MPI-OM). The RCP 45 projection of harvest and land use led to a decrease in fire carbon emissions by -5%. The RCP 26 and RCP 60 harvest and landuse projections caused decreases around -20%. Changes in human ignition led to an increase of 20%. When we also included changes in fire management efforts to suppress fires in densely populated areas, global fire carbon emission decreased by -6% in response to changes in population density. We concluded from this study that changes in fire emissions in the future are controlled by multiple interacting factors. Although changes in climate led to an increase in future fire emissions this could be globally counterbalanced by coupled changes in land use, harvest, and demography.
Foam as a Fire Suppressant: An Evaluation
Paul Schlobohm; Ron Rochna
1987-01-01
The ability of fire suppressant foams to improve ground-applied fire control efforts was evaluated. Foaming agents and foam-generating systems were examined. Performance evaluations were made for direct attack, indirect attack, and mop-up. Foam was determined to suppress and repel fire in situations where water did not. Cost comparisons of mop-up work showed straight...
Fire behavior in northern Rocky Mountain forests
J. S. Barrows
1951-01-01
Knowledge of fire behavior is an essential requirement for firefighters. Successful fire control operations depend, first of all, upon the ability of the protection forces to judge where and when fires will start and how they will behave once ignition takes place. Every member of the firefighting team from ranger to smokechaser must be able to make reliable estimates...
Flame characteristics for fires in southern fuels
Ralph M. Nelson
1980-01-01
A flame model and analytical method are used to derive forest fire flame characteristics. Approximate solutions are used to express flame lengths, angles, heights, and tip velocities of headfires and calm-air fires in terms of fire intensity. Equations are compared with data from low-intensity controlled burns in southern fuels and with data from the literature.
46 CFR 108.421 - Location of fire pumps and associated equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Location of fire pumps and associated equipment. 108.421... pumps and associated equipment. Each fire pump required by § 108.415, and the source of power, controls, sea connections for the fire pump, and booster pumps, if installed, must be installed in locations...
Living more safely in the chaparral-urban interface
Klaus W. H. Radtke
1983-01-01
Urban encroachment into chaparral areas has accelerated the fire-flood-erosion cycle. Preventative maintenance measures can help reduce the damage from fire and flood. This report describes the chaparral environment; how to cope with problems in watershed management, how to landscape for fire and soil erosion control, how to plan for home safety from fire, how to treat...
Simone Blair; Matt Campbell; Tom Lowe; Claire Campbell
2011-01-01
This paper explores the parallels that frequently exist in fire management organizations between operational approaches to fire and engagement approaches in the community. We observe that community issues are often treated in the same way as a fire incident—"controlled" and "contained" through education and "direct attack"...
Carolyn H. Sieg; Rodman R. Linn; Francois Pimont; Chad M. Hoffman; Joel D. McMillin; Judith Winterkamp; L. Scott Baggett
2017-01-01
Previous studies have suggested that bark beetles and fires can be interacting disturbances, whereby bark beetle-caused tree mortality can alter the risk and severity of subsequent wildland fires. However, there remains considerable uncertainty around the type and magnitude of the interaction between fires following bark beetle attacks, especially in drier forest types...
Physical characteristics of some northern California brush fuels
Clive M. Countryman
1982-01-01
Brush species make up much of the fuel load in forested wildlands. Basic physical and chemical characteristics of these species influence ease of ignition, rate of fire spread, burning time, and fire intensity. Quantitative knowledge of the variations in brush characteristics is essential to progress in fire control and effective use of fire in wildland management....
Fire scar mapping in a southern African savanna
Andrew T. Hudak; Bruce H. Brockett; Carol A. Wessman
1998-01-01
Multitemporal principal components analyses (PCAs) of pre- and post-burn Landsat Thematic Mapper images were used to map fire scars in Madikwe Game Reserve (MGR), South Africa. Prior to MGR's inception in 1991, when the land was used for extensive cattle ranching, overgrazing and fire suppression lead to bush encroachment. Fire is currently being used to control...
ERIC Educational Resources Information Center
Cordell, Curtis C.; And Others
A training effectiveness evaluation of the Navy Advanced Fire Fighting Training System was conducted. This system incorporates simulated fires as well as curriculum materials and instruction. The fires are non-pollutant, computer controlled, and installed in a simulated shipboard environment. Two teams of 15 to 16 persons, with varying amounts of…
NASA Astrophysics Data System (ADS)
Abdlmutalib, Ammar; Abdullatif, Osman
2017-04-01
Jurassic carbonates represent an important part of the Mesozoic petroleum system in the Arabian Peninsula in terms of source rocks, reservoirs, and seals. Jurassic Outcrop equivalents are well exposed in central Saudi Arabia and which allow examining and measuring different scales of geological heterogeneities that are difficult to collect from the subsurface due to limitations of data and techniques. Identifying carbonates Discontinuities characteristics at outcrops might help to understand and predict their properties and behavior in the subsurface. The main objective of this study is to identify the lithofacies and the discontinuities properties of the upper Jurassic carbonates of the Arab D member and the Jubaila Formation (Arab-D reservoir) based on their outcrop equivalent strata in central Saudi Arabia. The sedimentologic analysis revealed several lithofacies types that vary in their thickness, abundances, cyclicity and vertical and lateral stacking patterns. The carbonates lithofacies included mudstone, wackestone, packstone, and grainstone. These lithofacies indicate deposition within tidal flat, skeletal banks and shallow to deep lagoonal paleoenvironmental settings. Field investigations of the outcrops revealed two types of discontinuities within Arab D Member and Upper Jubaila. These are depositional discontinuities and tectonic fractures and which all vary in their orientation, intensity, spacing, aperture and displacements. It seems that both regional and local controls have affected the fracture development within these carbonate rocks. On the regional scale, the fractures seem to be structurally controlled by the Central Arabian Graben System, which affected central Saudi Arabia. While, locally, at the outcrop scale, stratigraphic, depositional and diagenetic controls appear to have influenced the fracture development and intensity. The fracture sets and orientations identified on outcrops show similarity to those fracture sets revealed in the upper Jurassic carbonates in the subsurface which suggest inter-relationships. Therefore, the integration of discontinuities characteristics revealed from the Arab-D outcrop with subsurface data might help to understand and predict discontinuity properties and patterns of the Arab-D reservoir in the subsurface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green,T.
This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policymore » for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the entire BNL site including the Upton Reserve and has been reviewed by, The Nature Conservancy, New York State Department of Environmental Conservation Forest Rangers, and DOE, as well as appropriate BNL emergency services personnel. The BNL Fire Department is the lead on wildfire suppression. However, the BNL Natural Resource Manager will be assigned to all wildland fires as technical resource advisor.« less
Risks, designs, and research for fire safety in spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.; Urban, David
1991-01-01
Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
Subsurface Controls on Stream Intermittency in a Semi-Arid Landscape
NASA Astrophysics Data System (ADS)
Dohman, J.; Godsey, S.; Thackray, G. D.; Hale, R. L.; Wright, K.; Martinez, D.
2017-12-01
Intermittent streams currently constitute 30% to greater than 50% of the global river network. In addition, the number of intermittent streams is expected to increase due to changes in land use and climate. These streams provide important ecosystem services, such as water for irrigation, increased biodiversity, and high rates of nutrient cycling. Many hydrological studies have focused on mapping current intermittent flow regimes or evaluating long-term flow records, but very few have investigated the underlying causes of stream intermittency. The disconnection and reconnection of surface flow reflects the capacity of the subsurface to accommodate flow, so characterizing subsurface flow is key to understanding stream drying. We assess how subsurface flow paths control local surface flows during low-flow periods, including intermittency. Water table dynamics were monitored in an intermittent reach of Gibson Jack Creek in southeastern Idaho. Four transects were delineated with a groundwater well located in the hillslope, riparian zone, and in the stream, for a total of 12 groundwater wells. The presence or absence of surface flow was determined by frequent visual observations as well as in situ loggers every 30m along the 200m study reach. The rate of surface water drying was measured in conjunction with temperature, precipitation, subsurface hydraulic conductivity, hillslope-riparian-stream connectivity and subsurface travel time. Initial results during an unusually wet year suggest different responses in reaches that were previously observed to occasionally cease flowing. Flows in the intermittent reaches had less coherent and lower amplitude diel variations during base flow periods than reaches that had never been observed to dry out. Our findings will help contribute to our understanding of mechanisms driving expansion and contraction cycles in intermittent streams, increase our ability to predict how land use and climate change will affect flow regimes, and improve management of our critical water resources.
NASA Astrophysics Data System (ADS)
Cahill, A. G.; Chao, J.; Forde, O.; Prystupa, E.; Mayer, K. U.; Black, T. A.; Tannant, D. D.; Crowe, S.; Hallam, S.; Mayer, B.; Lauer, R. M.; van Geloven, C.; Welch, L. A.; Salas, C.; Levson, V.; Risk, D. A.; Beckie, R. D.
2017-12-01
Fugitive gas, comprised primarily of methane, can be unintentionally released from upstream oil and gas development either at surface from leaky infrastructure or in the subsurface through failure of energy well bore integrity. For the latter, defective cement seals around energy well casings may permit buoyant flow of natural gas from the deeper subsurface towards shallow aquifers, the ground surface and potentially into the atmosphere. Concerns associated with fugitive gas release at surface and in the subsurface include contributions to greenhouse gas emissions, subsurface migration leading to accumulation in nearby infrastructure and impacts to groundwater quality. Current knowledge of the extent of fugitive gas leakage including how to best detect and monitor over time, and particularly its migration and fate in the subsurface, is incomplete. We have established an experimental field observatory for evaluating fugitive gas leakage in an area of historic and ongoing hydrocarbon resource development within the Montney Resource Play of the Western Canadian Sedimentary Basin, British Columbia, Canada. Natural gas will be intentionally released at surface and up to 25 m below surface at various rates and durations. Resulting migration patterns and impacts will be evaluated through examination of the geology, hydrogeology, hydro-geochemistry, isotope geochemistry, hydro-geophysics, vadose zone and soil gas processes, microbiology, and atmospheric conditions. The use of unmanned aerial vehicles and remote sensors for monitoring and detection of methane will also be assessed for suitability as environmental monitoring tools. Here we outline the experimental design and describe initial research conducted to develop a detailed site conceptual model of the field observatory. Subsequently, results attained from pilot surface and sub-surface controlled natural gas releases conducted in late summer 2017 will be presented as well as results of numerical modelling conducted to plan methane release experiments in 2018 and onwards. This research will create knowledge which informs strategies to detect and monitor fugitive gas fluxes at the surface and in groundwater; as well as guide associated regulatory and technical policies.
Controlling Fluid Flow in the Subsurface through Ureolysis-Controlled Mineral Precipitation
NASA Astrophysics Data System (ADS)
Gerlach, R.; Phillips, A. J.; Cunningham, A. B.; Spangler, L.
2016-12-01
In situ urea hydrolysis has been used by us successfully to manipulate the carbonate alkalinity and control the precipitation of carbonate minerals. Urea hydrolysis can be promoted using microbial cells, enzymes or thermal energy. This technology can be used to mitigate leakage pathways, seal fractures or control fluid transport in the subsurface in hydrocarbon production, enhanced geothermal energy storage, carbon sequestration, nuclear waste disposal, etc. We have completed two field demonstrations of the urea hydrolysis-controlled in situ mineral precipitation technology. The first demonstration showed fracture sealing was possible in a sandstone formation approx. 1120' below ground surface (bgs) and that the fracture had increased resistance to re-fracturing after mineralization treatment. The second field demonstration was performed in a well with an identified channel in the cement near the wellbore at approx. 1020' bgs. The in situ mineralization treatment resulted in reduced pressure decay during shut in periods and reduced injectivity. In addition, a noticeable difference was observed in the solids percentage in the ultrasonic imaging logs before and after biomineralization treatment. The presentation will summarize and put into context the field and our recent laboratory research focusing on permeability manipulation using the in situ ureolysis-driven mineralization technology under ambient and subsurface pressure conditions. We have demonstrated permeability reductions of 3-6 orders of magnitude in 100 µm to 4mm gaps between shale, sandstone and cement/steel interfaces.
Sheik, Cody S.; Reese, Brandi Kiel; Twing, Katrina I.; Sylvan, Jason B.; Grim, Sharon L.; Schrenk, Matthew O.; Sogin, Mitchell L.; Colwell, Frederick S.
2018-01-01
Earth’s subsurface environment is one of the largest, yet least studied, biomes on Earth, and many questions remain regarding what microorganisms are indigenous to the subsurface. Through the activity of the Census of Deep Life (CoDL) and the Deep Carbon Observatory, an open access 16S ribosomal RNA gene sequence database from diverse subsurface environments has been compiled. However, due to low quantities of biomass in the deep subsurface, the potential for incorporation of contaminants from reagents used during sample collection, processing, and/or sequencing is high. Thus, to understand the ecology of subsurface microorganisms (i.e., the distribution, richness, or survival), it is necessary to minimize, identify, and remove contaminant sequences that will skew the relative abundances of all taxa in the sample. In this meta-analysis, we identify putative contaminants associated with the CoDL dataset, recommend best practices for removing contaminants from samples, and propose a series of best practices for subsurface microbiology sampling. The most abundant putative contaminant genera observed, independent of evenness across samples, were Propionibacterium, Aquabacterium, Ralstonia, and Acinetobacter. While the top five most frequently observed genera were Pseudomonas, Propionibacterium, Acinetobacter, Ralstonia, and Sphingomonas. The majority of the most frequently observed genera (high evenness) were associated with reagent or potential human contamination. Additionally, in DNA extraction blanks, we observed potential archaeal contaminants, including methanogens, which have not been discussed in previous contamination studies. Such contaminants would directly affect the interpretation of subsurface molecular studies, as methanogenesis is an important subsurface biogeochemical process. Utilizing previously identified contaminant genera, we found that ∼27% of the total dataset were identified as contaminant sequences that likely originate from DNA extraction and DNA cleanup methods. Thus, controls must be taken at every step of the collection and processing procedure when working with low biomass environments such as, but not limited to, portions of Earth’s deep subsurface. Taken together, we stress that the CoDL dataset is an incredible resource for the broader research community interested in subsurface life, and steps to remove contamination derived sequences must be taken prior to using this dataset. PMID:29780369
Sheik, Cody S; Reese, Brandi Kiel; Twing, Katrina I; Sylvan, Jason B; Grim, Sharon L; Schrenk, Matthew O; Sogin, Mitchell L; Colwell, Frederick S
2018-01-01
Earth's subsurface environment is one of the largest, yet least studied, biomes on Earth, and many questions remain regarding what microorganisms are indigenous to the subsurface. Through the activity of the Census of Deep Life (CoDL) and the Deep Carbon Observatory, an open access 16S ribosomal RNA gene sequence database from diverse subsurface environments has been compiled. However, due to low quantities of biomass in the deep subsurface, the potential for incorporation of contaminants from reagents used during sample collection, processing, and/or sequencing is high. Thus, to understand the ecology of subsurface microorganisms (i.e., the distribution, richness, or survival), it is necessary to minimize, identify, and remove contaminant sequences that will skew the relative abundances of all taxa in the sample. In this meta-analysis, we identify putative contaminants associated with the CoDL dataset, recommend best practices for removing contaminants from samples, and propose a series of best practices for subsurface microbiology sampling. The most abundant putative contaminant genera observed, independent of evenness across samples, were Propionibacterium , Aquabacterium , Ralstonia , and Acinetobacter . While the top five most frequently observed genera were Pseudomonas , Propionibacterium , Acinetobacter , Ralstonia , and Sphingomonas . The majority of the most frequently observed genera (high evenness) were associated with reagent or potential human contamination. Additionally, in DNA extraction blanks, we observed potential archaeal contaminants, including methanogens, which have not been discussed in previous contamination studies. Such contaminants would directly affect the interpretation of subsurface molecular studies, as methanogenesis is an important subsurface biogeochemical process. Utilizing previously identified contaminant genera, we found that ∼27% of the total dataset were identified as contaminant sequences that likely originate from DNA extraction and DNA cleanup methods. Thus, controls must be taken at every step of the collection and processing procedure when working with low biomass environments such as, but not limited to, portions of Earth's deep subsurface. Taken together, we stress that the CoDL dataset is an incredible resource for the broader research community interested in subsurface life, and steps to remove contamination derived sequences must be taken prior to using this dataset.
[Observation on clinical therapeutic effect of improved thunder-fire miraculous needle on vertigo].
Zhang, Gong-an; Luo, Jian; Huang, Liu-he
2008-04-01
To Compare clinical therapeutic effect of improved thunder-fire miraculous needle and moxibustion on vertigo. One hundred and seventeen cases conformed with the TCM criteria of vertigo were randomly divided into an observation group (n=66) and a control group (n=51). The observation group were treated with improved thunder-fire miraculous needle and the control group with pressing and moxibustion at Baihui (GV 20). After treatment of one therapeutic course, the therapeutic effect was assessed by vertigo symptom rating scores. The total effective rate was 86.4% in the observation group and 66.7% in the control group, with a significant difference between the two groups (P<0.05). The improved thunder-fire miraculous needle can significantly relieve and eliminate symptoms of vertigo, with no adverse effect.